{"title":"Commercial Electric Boilers | Montreal, Laval, Longueuil, South Shore and North Shore","description":null,"products":[{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr600180p3-180-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR600180P3 Commercial Electric Boiler | 180 kW - 600V 3 Phase","description":"\u003ch2\u003e614,160 BTU\/h on 600 V to heat a large building with hot water\u003c\/h2\u003e\n\u003ch3\u003eA commercial boiler that adapts to the emitters\u003c\/h3\u003e\n\u003cp\u003eThe VoltMax SCR 180 is Thermo 2000’s 180 kW commercial electric boiler, here in its 600 V three-phase version. It delivers 614,160 BTU\/h according to the manufacturer and modulates its output from 0 to 100% through solid-state relays (SCR), alongside relay stages. Its setpoint adjusts from 50 °F to 200 °F (10 °C to 93 °C): high enough for a radiator system, low enough for a radiant floor.\u003c\/p\u003e\n\u003cp\u003eIt is meant for owners and managers of large residential, commercial or mixed-use buildings, engineers preparing a replacement and contractors modernizing a mechanical room. Hydro-air coils and an indirect water heater, served by a second setpoint, are also among its possible uses.\u003c\/p\u003e\n\u003ch3\u003eIn Quebec’s large buildings\u003c\/h3\u003e\n\u003cp\u003eTake a mixed-use building in \u003cstrong\u003eMontreal\u003c\/strong\u003e, with shops on the ground floor and offices upstairs, heated by an old radiator system. On 600 V three-phase, the VoltMax SCR 180 draws 173.2 A there. The supplied outdoor sensor lets the controller lower the water temperature in mild weather and raise it when it is cold, and schedules turn heating down when the premises are closed.\u003c\/p\u003e\n\u003cp\u003eIn a newer building in \u003cstrong\u003eLaval\u003c\/strong\u003e with a radiant floor, the same boiler runs at low temperature, still guided by the outdoor sensor. In both cases it stays compact: vertical, with 3 in of clearance on the sides and back, 24 in in front and 32 in above. It holds 30 US gal of water and weighs 550 lb (250 kg). The Schneider Electric controller displays in French or English, communicates over BACnet IP and MS-TP and sends its alarms by email.\u003c\/p\u003e\n\u003ch3\u003eOur work, from estimate to commissioning\u003c\/h3\u003e\n\u003cp\u003eThe on-site estimate is free. We check the 600 V service, the condition of the system and the emitters, and the access to the mechanical room. The written quote that follows specifies the boiler, the circulating pump and the expansion tank, which Thermo 2000 does not count among the supplied items.\u003c\/p\u003e\n\u003cp\u003eOur crews set the boiler in place, connect the system and the electrical circuit, fill and purge the loop, then set the setpoint, the outdoor reset curve and the schedules. The manufacturer, for its part, warrants the tank for 10 years, as a limited warranty for closed-loop heating, and the electrical and mechanical components for 2 years. A family business from \u003cstrong\u003eMontreal\u003c\/strong\u003e established for more than fifteen years, AirGreen works under RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical).\u003c\/p\u003e\n\u003ch3\u003eYour building, our quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn Montreal, Laval, Longueuil, on the North Shore or the South Shore, have your building assessed for free. You will receive a written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801486852388,"sku":"VOLTSCR600180P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR600180P3_180_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr600165p3-165-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR600165P3 Commercial Electric Boiler | 165 kW - 600V 3 Phase","description":"\u003ch2\u003e165 kW on 600 V to heat the building and its domestic hot water\u003c\/h2\u003e\n\u003ch3\u003eWhat it does and which buildings it suits\u003c\/h3\u003e\n\u003cp\u003eThe VoltMax SCR 165 is a Thermo 2000 commercial electric boiler, here in its 165 kW, 600 V three-phase version. The manufacturer rates it at 562,980 BTU\/h. Like any hot-water boiler, it heats a closed loop that feeds baseboards, radiators, a radiant floor or hydro-air coils. Its controller goes further: it manages a second setpoint for an indirect water heater, so the same boiler can also produce domestic hot water.\u003c\/p\u003e\n\u003cp\u003eThis two-in-one role appeals to owners of residential buildings, residences and managers of commercial buildings who want space heating and hot water in the same mechanical room.\u003c\/p\u003e\n\u003ch3\u003eTwo setpoints, one boiler\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric controller has a pump contact with or without domestic hot water priority. With priority, the indirect water heater is served first when it calls for heat; without priority, space heating and hot water share the output. The setpoint adjusts from 50 °F to 200 °F (10 °C to 93 °C), and the supplied outdoor sensor adjusts the heating water temperature to the weather.\u003c\/p\u003e\n\u003cp\u003eSCR modulation from 0 to 100%, through solid-state relays, matches output to actual demand, which limits peak power demand according to Thermo 2000. The controller shows its alarm codes in French or English and can send its alarms by email through its Ethernet port.\u003c\/p\u003e\n\u003ch3\u003eIn a Quebec building\u003c\/h3\u003e\n\u003cp\u003eOn a 600 V three-phase service, the VoltMax SCR 165 draws 158.8 A. For a residence in \u003cstrong\u003eMontreal\u003c\/strong\u003e or a building on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, the mechanical room has to hold the boiler, the indirect water heater and their pumps. The vertical boiler takes up little room there: 3 in of clearance on the sides and back, 24 in in front and 32 in above. It weighs 550 lb (250 kg) and holds 30 US gal of water.\u003c\/p\u003e\n\u003ch3\u003eThe installation, step by step\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate: electrical service, loop, emitters, hot water needs and available space. The written quote then specifies the boiler, the indirect water heater, the circulating pump and the expansion tank, the last three not being on Thermo 2000’s list of supplied items.\u003c\/p\u003e\n\u003cp\u003eOur crews install the boiler, connect the loop, the indirect water heater and the 600 V circuit, fill and purge the system, then set the two setpoints, the priority and the outdoor sensor. Thermo 2000 warrants the boiler’s tank for 10 years (limited warranty, closed-loop heating) and its electrical and mechanical components for 2 years. AirGreen, a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eGet your quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn Montreal, on the North Shore, in Laval, Longueuil or on the South Shore, the on-site estimate is free and the quote is in writing. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801495437604,"sku":"VOLTSCR600165P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR600165P3_165_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr600150p3-150-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR600150P3 Commercial Electric Boiler | 150 kW - 600V 3 Phase","description":"\u003ch2\u003e150 kW on 600 V, low-maintenance and monitored remotely\u003c\/h2\u003e\n\u003ch3\u003eA commercial boiler for buildings heated with hot water\u003c\/h3\u003e\n\u003cp\u003eFor a condominium board or a property manager, the boiler is equipment you keep for a long time. Two questions come up often: how to keep maintenance simple, and how to hear about an alarm before the occupants complain. Thermo 2000’s VoltMax SCR 150 has answers on both counts. This 150 kW commercial electric boiler (511,800 BTU\/h) runs on 600 V three-phase and modulates its output from 0 to 100% with solid-state relays.\u003c\/p\u003e\n\u003cp\u003eIt suits condominiums, rental buildings and commercial buildings whose loop feeds hot-water baseboards, radiators, a radiant floor or hydro-air coils.\u003c\/p\u003e\n\u003ch3\u003eMaintenance and monitoring in a Quebec building\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 describes the VoltMax as quiet, clean and low-maintenance. Its Incoloy immersion elements are replaceable, and the Schneider Electric controller shows alarm codes on its backlit display, in French or English. With network access in the mechanical room, the Ethernet port opens a web page and sends alarms by email: the manager of a condominium in \u003cstrong\u003eLaval\u003c\/strong\u003e is alerted without waiting for an occupant’s call.\u003c\/p\u003e\n\u003cp\u003eOn a 600 V three-phase service, common in Quebec buildings, the boiler draws 144.3 A. The supplied outdoor sensor adjusts the water temperature to the weather, and the controller’s second setpoint can supply an indirect water heater for domestic hot water. The vertical format stays compact: 3 in of clearance on the sides and back, 24 in in front and 32 in above, for 550 lb (250 kg) and 30 US gal of water.\u003c\/p\u003e\n\u003ch3\u003eWhat we do, from survey to commissioning\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate, with the manager or a member of the board of directors. We check the electrical service, the loop and the emitters, then hand over a written quote. It includes the circulating pump and the expansion tank, which are not on Thermo 2000’s list of supplied items.\u003c\/p\u003e\n\u003cp\u003eOn installation day, our crews set the boiler in place, connect the piping and the 600 V circuit, fill and purge the loop, then set up the controller, the outdoor sensor and the email addresses that will receive the alarms. Thermo 2000 warrants the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years, parts and accessories.\u003c\/p\u003e\n\u003cp\u003eA family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eA project for your building\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn Laval, Montreal, Longueuil, on the North Shore or the South Shore, ask for the free estimate: the quote is provided in writing, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801500320036,"sku":"VOLTSCR600150P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR600150P3_150_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr600144p3-144-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR600144P3 Commercial Electric Boiler | 144 kW - 600V 3 Phase","description":"\u003ch2\u003eA building heated on its own schedule, with 144 kW on 600 V\u003c\/h2\u003e\n\u003ch3\u003eA boiler for buildings that empty out in the evening\u003c\/h3\u003e\n\u003cp\u003eA school, a community centre or an office building does not have the same needs in the middle of a weekday as on a Sunday evening. Thermo 2000’s VoltMax SCR 144 is a 144 kW commercial electric boiler (491,328 BTU\/h), here in its 600 V three-phase version. Its Schneider Electric controller handles schedules, adjusts the water temperature with the supplied outdoor sensor and modulates output from 0 to 100% through solid-state relays (SCR) combined with relay stages.\u003c\/p\u003e\n\u003cp\u003eIt suits managers of institutional and commercial buildings, school service centres, municipalities and organizations that heat their premises with radiators, hot-water baseboards or radiant floors. It can also supply an indirect water heater through its second setpoint.\u003c\/p\u003e\n\u003ch3\u003eWhat it brings to a Quebec building\u003c\/h3\u003e\n\u003cp\u003e600 V three-phase power is common in Quebec’s institutional buildings; there, the VoltMax SCR 144 draws 138.6 A. In a community centre in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, for example, the outdoor sensor lowers the water temperature on mild autumn days, and the controller raises it during a cold snap, within the 50 °F to 200 °F setpoint range. In the evening and on weekends, the schedules take over.\u003c\/p\u003e\n\u003cp\u003eFor a manager in charge of several buildings, the Ethernet port changes daily life: a web page shows the boiler’s status and alarms arrive by email. The controller displays in French or English, in °C or °F, and also communicates over BACnet IP and MS-TP. For safety, Thermo 2000 supplies two limit controls, a factory-installed relief valve and, above 60 kW, a standard low-water cutoff.\u003c\/p\u003e\n\u003ch3\u003eHow we install it\u003c\/h3\u003e\n\u003cp\u003eIt all starts with a free on-site estimate, scheduled around the occupancy of your premises. We look at the 600 V service, the loop, the emitters and the access to the mechanical room: the boiler weighs 550 lb (250 kg) and needs 24 in in front, 32 in above and 3 in on the sides and back. You then receive a written quote that includes the circulating pump and the expansion tank, which are not on Thermo 2000’s list of supplied items.\u003c\/p\u003e\n\u003cp\u003eAt installation, our crews connect the piping and the electrical circuit, fill and purge the loop, then program the schedules, the outdoor reset curve and the email alarms with your building manager. Thermo 2000 warrants the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003ePlanning the replacement\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs your building in Longueuil, Montreal, Laval, on the South Shore or the North Shore? Let’s schedule the free estimate: you will receive a written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801517064484,"sku":"VOLTSCR600144P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR600144P3_144_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr600132p3-132-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR600132P3 Commercial Electric Boiler | 132 kW - 600V 3 Phase","description":"\u003ch2\u003e132 kW, modulated from 0 to 100%, to heat a building on 600 V power\u003c\/h2\u003e\n\u003ch3\u003eA commercial boiler for buildings with a hot-water loop\u003c\/h3\u003e\n\u003cp\u003eThe VoltMax SCR 132 is Thermo 2000’s 132 kW commercial electric boiler, in its 600 V three-phase version. The manufacturer rates it at 450,384 BTU\/h and places it in its configuration B, which runs from 99 to 180 kW. Its name comes from its modulation: solid-state relays (SCR) vary the output from 0 to 100%, alongside relay stages.\u003c\/p\u003e\n\u003cp\u003eIt is meant for managers of apartment buildings, condominium boards and owners of commercial or institutional buildings heated with hot water: hot-water baseboards, radiators, radiant floors or hydro-air coils. It can also supply an indirect water heater, thanks to the second setpoint built into its controller.\u003c\/p\u003e\n\u003ch3\u003eIts place in a Quebec building\u003c\/h3\u003e\n\u003cp\u003eMany Quebec buildings receive 600 V three-phase power. On that service, the VoltMax SCR 132 draws 127 A. Rather than switching full blocks of power on and off, it adjusts its output to the building’s demand; Thermo 2000 points out that this modulation limits peak power demand. The supplied outdoor sensor lets the controller lower the water temperature on mild days and raise it when the cold sets in.\u003c\/p\u003e\n\u003cp\u003eTake an apartment building in \u003cstrong\u003eMontreal\u003c\/strong\u003e whose old boiler sits in a corner of the mechanical room. The VoltMax is vertical and needs only 3 in of clearance on the sides and back, 24 in in front and 32 in above. It holds 30 US gal of water, connects through four 2 1\/2 in NPT side connections and accepts a setpoint from 50 °F to 200 °F. At 550 lb (250 kg), its delivery takes some preparation: access, stairs, dolly.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate: electrical service, condition of the loop, existing emitters and available space. You then receive a written quote that names the boiler and everything that goes with it. The circulating pump and the expansion tank are not on Thermo 2000’s list of supplied items; we size them for your system.\u003c\/p\u003e\n\u003cp\u003eOn installation day, our crews set the boiler in place, connect the piping and the 600 V supply, fill and purge the loop, then set up the Schneider Electric controller and the outdoor reset curve. If the building has a management system, the boiler can be linked to it through BACnet IP or MS-TP. Thermo 2000 warrants the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. That is why we handle the boiler’s electrical connection ourselves.\u003c\/p\u003e\n\u003ch3\u003eLet’s talk about your building\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs your building in Montreal, Laval, Longueuil, on the North Shore or the South Shore? Ask for your free estimate: you receive the quote in writing, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801538101540,"sku":"VOLTSCR600132P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR600132P3_132_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr600120p3-120-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR600120P3 Commercial Electric Boiler | 120 kW - 600V 3 Phase","description":"\u003ch2\u003eReplacing a building’s central boiler with a 120 kW, 600 V VoltMax SCR\u003c\/h2\u003e\n\u003ch3\u003eFor buildings heated by a central boiler\u003c\/h3\u003e\n\u003cp\u003eIn a condominium in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, a housing co-op in \u003cstrong\u003eMontreal\u003c\/strong\u003e or a multi-storey rental building, a single electric boiler often heats every unit. When it reaches the end of its life, the condo board or the manager has to replace it while keeping the heating shutdown as short as possible. Thermo 2000’s VoltMax SCR 120, on 600 V three-phase (manufacturer designation: VOLTMAX SCR 120-600-3 PH), is a serious candidate for this kind of replacement.\u003c\/p\u003e\n\u003cp\u003eIt delivers 120 kW, or 409,440 BTU\/h, and heats a closed loop that serves radiators, hot-water baseboards, a radiant floor or an indirect water heater. It belongs to the series’ configuration B: 30 US gal of water, 2 1\/2 in male NPT connections, 550 lb and a maximum working pressure of 125 psi (862 kPa) as standard.\u003c\/p\u003e\n\u003ch3\u003eWhat the new boiler changes day to day\u003c\/h3\u003e\n\u003cp\u003eFor the maintenance staff, the most visible change is the Schneider Electric controller: a 3 in backlit LCD, alarm codes, a French or English display, in °C or °F. It adjusts water temperature from the included outdoor sensor, over a range of 50 °F to 200 °F, and follows schedules if needed.\u003c\/p\u003e\n\u003cp\u003eOn the electrical side, output is modulated from 0 to 100% through solid-state relays (SCR), on top of the relay stages. Thermo 2000 points out that this modulation limits peak power, and the boiler draws 115.5 A on 600 V three-phase. Its Ethernet port gives access to a web page and email alarms; it also communicates over BACnet IP or MS-TP.\u003c\/p\u003e\n\u003ch3\u003eHow we carry out the replacement\u003c\/h3\u003e\n\u003cp\u003eEverything starts with a free on-site estimate. We note the 600 V service, the condition of the loop and emitters, and the route to take the old boiler out and bring the new one in. The written quote specifies the parts to add, including the circulator and expansion tank, which Thermo 2000 does not supply.\u003c\/p\u003e\n\u003cp\u003eWe then schedule the work with the condo board or the manager, preferably outside the heating season. On the day, our crews remove the old unit, set the VoltMax SCR 120 in place with its clearances (24 in in front, 32 in above, 3 in on the sides and back), connect the loop and the 600 V supply, mount the outdoor sensor, then fill and purge the circuit. Before leaving, we walk your maintenance lead through the basic settings.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. AirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years; we hold RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eLet’s plan your replacement\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFor a building in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for a free estimate: the quote is in writing, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801559531812,"sku":"VOLTSCR600120P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR600120P3_120_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082241"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr600108p3-108-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR600108P3 Commercial Electric Boiler | 108 kW - 600V 3 Phase","description":"\u003ch2\u003e108 kW on 600 V for radiator buildings, set to the outdoor temperature\u003c\/h2\u003e\n\u003ch3\u003eBuildings that still heat with radiators\u003c\/h3\u003e\n\u003cp\u003eMany office buildings in downtown \u003cstrong\u003eMontreal\u003c\/strong\u003e and rental buildings in \u003cstrong\u003eLaval\u003c\/strong\u003e still heat their spaces with hot-water radiators. When the electric boiler reaches the end of its life, it has to be replaced without touching the distribution. Thermo 2000’s VoltMax SCR 108, on 600 V three-phase (manufacturer designation: VOLTMAX SCR 108-600-3 PH), is a serious option for these sizeable buildings.\u003c\/p\u003e\n\u003cp\u003eIt delivers 108 kW, or 368,496 BTU\/h, and belongs to the series’ configuration B: 30 US gal of water, four 2 1\/2 in male NPT side connections and a maximum working pressure of 125 psi (862 kPa) as standard.\u003c\/p\u003e\n\u003ch3\u003eWater at the right temperature, from autumn to deep cold\u003c\/h3\u003e\n\u003cp\u003eA radiator does not need the same water in October as in January. The included outdoor sensor lets the Schneider Electric controller follow a curve: the water stays moderate in mild weather and rises as the cold sets in, over a setpoint range of 50 °F to 200 °F (10 °C to 93 °C). Occupants gain comfort, and the boiler does not heat more than it needs to.\u003c\/p\u003e\n\u003cp\u003eThe controller also follows schedules, useful in an office building that is empty at night and on weekends. It can handle a second setpoint for an indirect water heater, communicate over BACnet IP or MS-TP and send its alarms by email through its Ethernet port.\u003c\/p\u003e\n\u003cp\u003eOn the electrical side, Thermo 2000 lists 103.9 A on 600 V three-phase. Output is modulated from 0 to 100% through solid-state relays, on top of the relay stages, which limits peak power according to the manufacturer.\u003c\/p\u003e\n\u003ch3\u003eThe replacement, done by AirGreen\u003c\/h3\u003e\n\u003cp\u003eIn an older building, the on-site estimate counts double: we check the 600 V service, the mechanical room, the condition of the radiators and the loop, and the route to deliver a 550 lb boiler. The estimate is free, and the written quote specifies the parts to add, including the circulator and expansion tank, which Thermo 2000 does not supply.\u003c\/p\u003e\n\u003cp\u003eOn installation day, our crews remove the old boiler, install the VoltMax SCR 108 with its clearances (24 in in front, 32 in above, 3 in on the sides and back), connect it to the existing loop and the 600 V supply, mount the outdoor sensor, then fill and purge the circuit. We then set the curve and the schedules with you.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. AirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years; we hold RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eLet’s replace your boiler\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for your free estimate: the quote is in writing, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801589973284,"sku":"VOLTSCR600108P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR600108P3_108_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr60099p3-99-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR60099P3 Commercial Electric Boiler | 99 kW - 600V 3 Phase","description":"\u003ch2\u003e99 kW on 600 V, with the certifications an institutional project checks\u003c\/h2\u003e\n\u003ch3\u003eFor buildings where everything goes through a specification\u003c\/h3\u003e\n\u003cp\u003eIn a school in \u003cstrong\u003eMontreal\u003c\/strong\u003e, a seniors’ residence in \u003cstrong\u003eLongueuil\u003c\/strong\u003e or a public building on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, choosing a boiler is rarely up to the owner alone. The engineer writes a specification, the manager checks compliance, the inspector looks at the nameplates. Thermo 2000’s VoltMax SCR 99, on 600 V three-phase (manufacturer designation: VOLTMAX SCR 99-600-3 PH), fits well into that framework, and the manufacturer also publishes an engineering specification for the series.\u003c\/p\u003e\n\u003cp\u003eIt is a 99 kW commercial electric boiler, or 337,788 BTU\/h, in the series’ format B: 30 US gal of water, four 2 1\/2 in male NPT side connections, 550 lb. It heats a closed loop of radiators, a radiant floor, hot-water coils or an indirect water heater.\u003c\/p\u003e\n\u003ch3\u003eCertifications and working pressure\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 lists the CSA C22.2 No. 165-92 and UL 834 standards for this model, with the CSA mark for Canada and the United States. The tank complies with CSA B-51-14 and carries a CRN registration as well as the ASME Section IV \"H\" stamp. The published maximum working pressure is 125 psi (862 kPa) as standard.\u003c\/p\u003e\n\u003cp\u003eOn the electrical side, the boiler draws 95.3 A on 600 V three-phase, a common voltage in Québec institutional buildings. It modulates its output from 0 to 100% through solid-state relays, on top of its relay stages, and Thermo 2000 states that this modulation limits peak power.\u003c\/p\u003e\n\u003cp\u003eFor operation, the Schneider Electric controller handles outdoor reset (sensor included), schedules, a second setpoint for an indirect water heater and BACnet IP or MS-TP communication. Its alarms show on screen and go out by email through the Ethernet port.\u003c\/p\u003e\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate, then provide a written quote that follows the engineer’s specification if there is one. It also lists the parts Thermo 2000 does not supply, such as the circulator and expansion tank. The manufacturer’s spec sheet, installation manual and brochure are available in the Documents section of this page.\u003c\/p\u003e\n\u003cp\u003eOn site, our crews deliver the 550 lb boiler, set it in place with 24 in clear in front, 32 in above and 3 in on the sides and back, connect the loop in 2 1\/2 in, wire the 600 V supply and the outdoor sensor, fill and purge the circuit, then commission it.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. AirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eYour institutional project\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for your free estimate: the quote is in writing, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801617039652,"sku":"VOLTSCR60099P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR60099P3_99_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082241"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr60090p3-90-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR60090P3 Commercial Electric Boiler | 90 kW - 600V 3 Phase","description":"\u003ch2\u003e90 kW on 600 V, run by the building’s system or by its own controller\u003c\/h2\u003e\n\u003ch3\u003eA commercial boiler that fits into a control sequence\u003c\/h3\u003e\n\u003cp\u003eIn a clinic in \u003cstrong\u003eLaval\u003c\/strong\u003e or a shopping centre on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, heating often goes through the hot-water coils of the air handling units, and a management system decides when to heat and to what temperature. Thermo 2000’s VoltMax SCR 90, on 600 V three-phase (manufacturer designation: VOLTMAX SCR 90-600-3 PH), suits that role well: it can take its orders from outside.\u003c\/p\u003e\n\u003cp\u003eIt delivers 90 kW, or 307,080 BTU\/h, and heats a closed loop that can serve coils, radiators, a radiant floor or an indirect water heater. Thermo 2000 designs it for commercial and institutional buildings.\u003c\/p\u003e\n\u003ch3\u003eTwo ways to control it, and a third without a central system\u003c\/h3\u003e\n\u003cp\u003eFirst way: a 0-10 Vdc signal. The building system imposes the water temperature setpoint or the boiler’s output. Second way: BACnet IP or MS-TP communication, which also lets the system read status and alarms. And if the building has no central system, the Schneider Electric controller does the job on its own, with the included outdoor sensor, schedules and a setpoint adjustable from 50 °F to 200 °F.\u003c\/p\u003e\n\u003cp\u003eIn every case, output is modulated from 0 to 100% through solid-state relays (SCR), on top of the relay stages, and the controller rotates its stages. Thermo 2000 states that this modulation limits peak power. On 600 V three-phase, the boiler draws 86.6 A.\u003c\/p\u003e\n\u003cp\u003ePhysically, it is the largest configuration A model: a 310 lb vertical cabinet holding 11 US gal of water, with 3 in of clearance on the sides and back, 24 in in front and 32 in above.\u003c\/p\u003e\n\u003ch3\u003eInstallation, coordinated by AirGreen\u003c\/h3\u003e\n\u003cp\u003eThe free on-site estimate lets us check the 600 V service, the loop and the planned sequence. We then give you a written quote specifying the boiler and the components to add, including the circulator and expansion tank, which Thermo 2000 does not supply.\u003c\/p\u003e\n\u003cp\u003eOur crews install the boiler, connect the piping to the 1 1\/2 in NPT side connections, wire the 600 V supply and the control wiring, then fill and purge the loop. Commissioning is done with the engineer or the management system integrator when the building has one.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. AirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years and holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eYour commercial project\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for your free estimate: the quote is in writing, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801635815716,"sku":"VOLTSCR60090P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR60090P3_90_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082241"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr60075p3-75-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR60075P3 Commercial Electric Boiler | 75 kW - 600V 3 Phase","description":"\u003ch2\u003eA 75 kW, 600 V boiler the building manager can monitor remotely\u003c\/h2\u003e\n\u003ch3\u003eFor buildings where nobody watches the mechanical room\u003c\/h3\u003e\n\u003cp\u003eMany commercial and institutional buildings run without technical staff on site. A church on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e heated all week for a few hours of use, a community hall in \u003cstrong\u003eLaval\u003c\/strong\u003e, a small office building managed by an outside firm: when the boiler stops, people often find out from the occupants. Thermo 2000’s VoltMax SCR 75 has what it takes to avoid that kind of surprise.\u003c\/p\u003e\n\u003cp\u003eIt is a 75 kW commercial electric boiler, or 255,900 BTU\/h, here on 600 V three-phase (manufacturer designation: VOLTMAX SCR 75-600-3 PH). It heats a closed loop that serves radiators, a radiant floor, the coils of an air handling unit or an indirect water heater.\u003c\/p\u003e\n\u003ch3\u003eRemote monitoring built into the controller\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric controller includes an Ethernet port. Once connected to the building network, it gives access to a web page and sends alarms by email: the manager is notified without having to travel. On site, the 3 in backlit LCD shows alarm codes in French or English, which helps the technician target the repair.\u003c\/p\u003e\n\u003cp\u003eFor a portfolio that already has a central management system, the boiler communicates over BACnet IP or MS-TP and accepts an external 0-10 Vdc command. Without a central system, it sets water temperature itself using the included outdoor sensor and its schedules.\u003c\/p\u003e\n\u003cp\u003eOn the electrical side, Thermo 2000 lists 72.2 A on 600 V three-phase. Output is modulated from 0 to 100% through solid-state relays, on top of the relay stages, which limits peak power according to the manufacturer. Quiet, clean and low-maintenance, again according to Thermo 2000, it uses replaceable Incoloy immersion elements.\u003c\/p\u003e\n\u003ch3\u003eInstallation, done by AirGreen\u003c\/h3\u003e\n\u003cp\u003eAfter a free on-site estimate, we give you a written quote. It takes into account the 600 V service, the existing loop and what Thermo 2000 does not supply, such as the circulator and expansion tank. If you want email alarms, we also plan the connection of the Ethernet port to the building network.\u003c\/p\u003e\n\u003cp\u003eOur crews then set the 310 lb boiler in place (24 in clear in front, 32 in above, 3 in on the sides and back), connect the 1 1\/2 in NPT piping and the 600 V supply, mount the outdoor sensor, then fill and purge the loop. Commissioning includes setting the setpoint, the outdoor reset curve and the alarm recipients.\u003c\/p\u003e\n\u003cp\u003eThermo 2000’s warranty covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. AirGreen, a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eLet’s talk about your buildings\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhether your buildings are in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for a free estimate: the quote is in writing and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801651478820,"sku":"VOLTSCR60075P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR60075P3_75_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082241"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr60072p3-72-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR60072P3 Commercial Electric Boiler | 72 kW - 600V 3 Phase","description":"\u003ch2\u003e72 kW on 600 V for schools, offices and institutional buildings\u003c\/h2\u003e\n\u003ch3\u003eA building heated to match its occupancy\u003c\/h3\u003e\n\u003cp\u003eA school, a daycare or an office building does not need the same heat at every hour. Thermo 2000’s VoltMax SCR 72, here on 600 V three-phase (manufacturer designation: VOLTMAX SCR 72-600-3 PH), heats the hot-water loop of this kind of building and follows its occupants’ rhythm through schedules and an included outdoor sensor.\u003c\/p\u003e\n\u003cp\u003eWith 72 kW, or 245,664 BTU\/h, it supplies radiators, a radiant floor, the hot-water coils of an air handling unit or an indirect water heater. Thermo 2000 lists it among its commercial and institutional boilers, and its water setpoint adjusts from 50 °F to 200 °F.\u003c\/p\u003e\n\u003ch3\u003e600 V, the voltage of many Québec buildings\u003c\/h3\u003e\n\u003cp\u003eIn Québec, a good share of commercial and institutional buildings receive 600 V three-phase. On that voltage, the VoltMax SCR 72 draws 69.3 A, according to Thermo 2000. We confirm it on site, at the panel, before any quote, whether the building is in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e or elsewhere on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer stresses three qualities: the boiler is quiet, clean and needs little maintenance. Its Incoloy immersion elements are replaceable, and its Schneider Electric controller displays alarm codes in French or English, in °C or °F. For a janitor or a manager who is not a technician, the backlit screen makes routine checks simpler.\u003c\/p\u003e\n\u003cp\u003eOutput is modulated from 0 to 100% through solid-state relays (SCR), on top of the relay stages. Thermo 2000 states that this modulation limits peak power. If the building has a central management system, the boiler connects to it over BACnet IP or MS-TP, or follows a 0-10 Vdc signal.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen does, from estimate to commissioning\u003c\/h3\u003e\n\u003cp\u003eWe first visit the building, free of charge: 600 V service, mechanical room, existing loop and emitters. You then receive a written quote. It names the boiler and what goes around it, including the circulator and expansion tank, since Thermo 2000 does not include them in its list of supplied components.\u003c\/p\u003e\n\u003cp\u003eThe work is scheduled with the building’s management. Our crews set the 310 lb boiler in place leaving 24 in in front, 32 in above and 3 in on the sides and back, connect the piping to the 1 1\/2 in NPT connections, wire the 600 V supply, mount the outdoor sensor, fill and purge the loop. We then program the setpoint, the outdoor reset curve and the occupancy schedules.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years, parts and accessories. AirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eLet’s plan your project\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFor a building in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for your free on-site estimate. You will receive a written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801666552100,"sku":"VOLTSCR60072P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR60072P3_72_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082241"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr60060p3-60-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR60060P3 Commercial Electric Boiler | 60 kW - 600V 3 Phase","description":"\u003ch2\u003eReplace your 600 V office building boiler with a 60 kW VoltMax with modulated output\u003c\/h2\u003e\n\u003ch3\u003eWhen the old boiler shows its age\u003c\/h3\u003e\n\u003cp\u003eIn many office and commercial buildings, the original electric boiler still runs in stages, with no modulation or communication. When it is time to replace it, Thermo 2000’s VoltMax 60 offers a complete upgrade. This 600 V three-phase model delivers 60 kW, or 204,720 BTU\/h, to the existing water loop: radiators, hydro-air coils or radiant floors.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 publishes a current of 57.7 A for this model. The VoltMax SCR series is aimed precisely at commercial, institutional and multi-unit buildings.\u003c\/p\u003e\n\u003ch3\u003eWhat the VoltMax 60 changes day to day\u003c\/h3\u003e\n\u003cp\u003eThe solid-state relay (SCR) varies output from 0 to 100%, instead of switching on whole stages; according to the manufacturer, this limits peak power demand. The included outdoor sensor sets water temperature by the weather, within a setpoint range of 50 °F to 200 °F (10 °C to 93 °C), and the controller handles schedules matched to office hours.\u003c\/p\u003e\n\u003cp\u003eFor the manager, the Schneider Electric controller communicates over BACnet IP or MS-TP with the building management system, accepts a 0-10 Vdc signal and sends its alarms by email through its Ethernet port. On site, the 3 in backlit display shows alarm codes in French or English. The Incoloy immersion elements are replaceable, and the manufacturer describes the unit as quiet, clean and low-maintenance.\u003c\/p\u003e\n\u003ch3\u003eA planned replacement\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eWe survey the old boiler, the water loop, the 600 V supply and the mechanical room.\u003c\/li\u003e\n\u003cli\u003eWe check that the VoltMax 60 matches the building’s heating load, or suggest a neighbouring 600 V size in the series, such as the 54 kW or 72 kW VoltMax.\u003c\/li\u003e\n\u003cli\u003eWe confirm the space: 3 in of clearance on the sides and back, 24 in at the front, 32 in above, set on the floor, 310 lb (141 kg).\u003c\/li\u003e\n\u003cli\u003eWe specify what is added: circulator and expansion tank, which are not among the supplied parts, and the low water cut-off, optional at 60 kW.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eIdeally, the work is done outside the heating season, so the building is never left without heat.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eThe on-site estimate is free and the quote is in writing. On installation day, our technicians drain and remove the old boiler, set the VoltMax in place, connect it to the loop through its 1 1\/2 in male NPT side connections, extend the discharge of the factory-installed relief valve and make the electrical connection. They mount the outdoor sensor, fill and purge the system, then set the setpoint, schedules and alarms with your manager.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eLet’s plan the replacement\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Ask for your free estimate now; you receive a written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801678315812,"sku":"VOLTSCR60060P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR60060P3_60_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082219"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr60054p3-54-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR60054P3 Commercial Electric Boiler | 54 kW - 600V 3 Phase","description":"\u003ch2\u003eA 54 kW, 600 V electric boiler for hot-water heating in workshops, warehouses and commercial buildings\u003c\/h2\u003e\n\u003ch3\u003eFor industrial and commercial buildings on 600 V\u003c\/h3\u003e\n\u003cp\u003e600 V three phase is a common voltage in industrial and commercial buildings in Quebec. Thermo 2000’s VoltMax SCR comes in this voltage, and the 54 kW size draws a current of 52 A on it, according to the manufacturer. It produces 184,248 BTU\/h and heats the water in a hydronic loop: heated slab, radiators or the coils of a hydro-air system.\u003c\/p\u003e\n\u003cp\u003eYou find it in a mechanic’s workshop with a heated slab, in warehouse offices, in a municipal garage or in a commercial space. Its controller can also supply an indirect water heater through a second setpoint, with or without domestic hot water priority.\u003c\/p\u003e\n\u003ch3\u003eA properly tuned heated slab\u003c\/h3\u003e\n\u003cp\u003eA concrete slab reacts slowly. To keep it comfortable without overheating it, water temperature has to follow the weather. The included outdoor sensor does exactly that: when the cold deepens, the Schneider Electric controller raises the supply temperature, and it lowers it again in mild weather. The setpoint ranges from 50 °F to 200 °F (10 °C to 93 °C), which covers a radiant floor as well as radiators.\u003c\/p\u003e\n\u003cp\u003eOutput, for its part, varies from 0 to 100% thanks to the solid-state relay (SCR), complemented by relay stages that the controller rotates. According to Thermo 2000, this modulation limits peak power demand. For a building run by a PLC, the setpoint and output can follow a 0-10 Vdc signal, or go through BACnet IP or MS-TP.\u003c\/p\u003e\n\u003ch3\u003ePractical points\u003c\/h3\u003e\n\u003cp\u003eThe boiler is vertical and compact: 310 lb (141 kg), 11 US gal of water, and clearances of 3 in on the sides and back, 24 in at the front and 32 in above. It can sit directly on the floor. Its Incoloy immersion elements are replaceable, and the manufacturer describes it as quiet, clean and low-maintenance. The circulator and expansion tank are not among the supplied parts, and the low water cut-off is an option at 54 kW.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eOur installation\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate. We survey the loop or slab, the mechanical room and the 600 V electrical service, then prepare a written quote that includes the circulator, the expansion tank and, if needed, the low water cut-off. Our technicians then install the boiler, connect it through its 1 1\/2 in NPT side connections, make the electrical connection, mount the outdoor sensor, fill and purge the system, then set the heating curve with you.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eYour building, our quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe install the VoltMax SCR in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Ask for your free estimate: the quote is in writing, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801679986980,"sku":"VOLTSCR60054P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR60054P3_54_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082219"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr60045p3-45-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR60045P3 Commercial Electric Boiler | 45 kW - 600V 3 Phase","description":"\u003ch2\u003eA 45 kW electric boiler on 600 V for commercial and institutional construction projects\u003c\/h2\u003e\n\u003ch3\u003eThe VoltMax 45 on 600 V three phase\u003c\/h3\u003e\n\u003cp\u003eThermo 2000’s VoltMax is a hot water electric boiler designed for commercial and institutional buildings. The series covers 22.5 to 180 kW. This model, designated VOLTMAX SCR 45-600-3 PH, delivers 45 kW, or 153,540 BTU\/h, and draws 43.3 A on 600 V three phase. It belongs to configuration A (22.5 to 90 kW).\u003c\/p\u003e\n\u003cp\u003eIn a new building or an addition supplied at 600 V, it heats the water of a closed loop that serves radiant floors, radiators or the coils of ventilation units.\u003c\/p\u003e\n\u003ch3\u003eWhat designers want to know\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 lists the CSA C22.2 No. 165-92 and UL 834 standards for the VoltMax, with the CSA mark for Canada and the United States. The tank meets CSA B-51-14 and carries a CRN registration as well as the ASME Section IV “H” stamp. According to the manufacturer’s most recent engineering specification, the series is now offered in the SCR version only.\u003c\/p\u003e\n\u003cp\u003eOn the controls side, the Schneider Electric controller communicates over BACnet IP or MS-TP and accepts an external 0-10 Vdc signal for setpoint and output. It modulates output from 0 to 100% through solid-state relays, in addition to relay stages, and Thermo 2000 points out that this modulation limits peak power demand. Its Ethernet port provides a web page and email alarms, and the outdoor sensor is included.\u003c\/p\u003e\n\u003cp\u003eOn the mechanical side: four 1 1\/2 in male NPT side connections, relief valve and drain at 3\/4 in female NPT, 11 US gal of water (41.6 L) and a weight of 310 lb (141 kg). The required clearances are 24 in in front, 32 in above, 3 in on the sides and at the back, with no clearance at the floor. The setpoint ranges from 50 °F to 200 °F.\u003c\/p\u003e\n\u003ch3\u003eWhat installation by AirGreen covers\u003c\/h3\u003e\n\u003cp\u003eWe work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. For a new project, we start from the drawings and specifications: we confirm the model, the voltage and the accessories to plan for, including the circulator and expansion tank, which are not among the parts supplied by Thermo 2000, and the low water cut-off, available as an option on this size. You receive a detailed written quote.\u003c\/p\u003e\n\u003cp\u003eOn site, our technicians install the boiler, connect it to the loop, pipe the relief valve discharge, mount the outdoor sensor and make the electrical connection under our RBQ licence 5645-9605-01, which covers ventilation, refrigeration and electrical work. We then program the controller and coordinate the BACnet integration with the project’s integrator.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years. Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eLet’s talk about your project\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTo include a 45 kW VoltMax on 600 V in your project, ask for a free estimate. We give you a written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801683558692,"sku":"VOLTSCR60045P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR60045P3_45_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082218"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr60036p3-36-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR60036P3 Commercial Electric Boiler | 36 kW - 600V 3 Phase","description":"\u003ch2\u003eA 36 kW electric boiler on 600 V to replace the one in your school, offices or community centre\u003c\/h2\u003e\n\u003ch3\u003eThe VoltMax 36 at a glance\u003c\/h3\u003e\n\u003cp\u003eThe VoltMax is Thermo 2000’s commercial and institutional electric boiler. This 36 kW model runs on 600 V three phase, a common voltage in Québec’s commercial and institutional buildings. It produces 122,832 BTU\/h, draws 34.6 A and belongs to the series’ configuration A (22.5 to 90 kW).\u003c\/p\u003e\n\u003cp\u003eLike the other SCR models, it modulates its output from 0 to 100% through solid-state relays, in addition to relay stages. Thermo 2000 points out that this modulation limits the building’s peak power demand.\u003c\/p\u003e\n\u003ch3\u003eReplacing a boiler at the end of its life\u003c\/h3\u003e\n\u003cp\u003eIn a school, a community centre or an office building, the original electric boiler often reaches the end of its life while the hot water loop, radiators and floors remain in good condition. The VoltMax 36 takes its place: it connects to the existing loop through its 1 1\/2 in NPT side connections and heats the water to a setpoint adjustable from 50 °F to 200 °F.\u003c\/p\u003e\n\u003cp\u003eThe mechanical room of an institutional building is rarely spacious. The VoltMax’s vertical design needs only 3 in of clearance on the sides and at the back, none at the floor, 24 in in front and 32 in above. The unit weighs 310 lb (141 kg): we plan its route to the room, doors and stairs included.\u003c\/p\u003e\n\u003cp\u003eThe Schneider Electric controller is made for all staff: 3 in backlit LCD, alarm codes, display in French or English, in °C or °F. The included outdoor sensor adjusts the water to the weather. The Ethernet port provides a web page and email alarms, and the controller communicates over BACnet IP or MS-TP with a building management system.\u003c\/p\u003e\n\u003ch3\u003eWhat installation by AirGreen covers\u003c\/h3\u003e\n\u003cp\u003eThe on-site estimate is free in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. We survey the boiler in place, the 600 V supply, and the condition of the loop, circulator and expansion tank, since these two parts are not supplied with the VoltMax. The written quote describes the removal of the old unit, the installation of the new boiler and the parts to replace.\u003c\/p\u003e\n\u003cp\u003eOn the day of the work, we drain the loop, remove the old boiler, set the VoltMax in place and connect it. We pipe the discharge of the factory-installed relief valve, mount the outdoor sensor and make the electrical connection. The loop is then filled and purged, and the controller is programmed with your maintenance lead.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eLet’s prepare the replacement\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTo replace your building’s boiler with a 36 kW VoltMax on 600 V, ask for a free estimate. You receive a written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801685721380,"sku":"VOLTSCR60036P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR60036P3_36_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082219"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr60030p3-30-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR60030P3 Commercial Electric Boiler | 30 kW - 600V 3 Phase","description":"\u003ch2\u003e30 kW connected directly to 600 V three phase, for only 28.9 A\u003c\/h2\u003e\n\u003ch3\u003eWhy a 600 V version\u003c\/h3\u003e\n\u003cp\u003e600 V three phase supplies many commercial and industrial buildings and large apartment buildings in Quebec. In these buildings, Thermo 2000’s VoltMax SCR 30-600-3 PH connects directly to the available voltage. It delivers 30 kW, or 102,360 BTU\/h according to the manufacturer, and draws only 28.9 A at full output.\u003c\/p\u003e\n\u003cp\u003eIt is an electric hot-water boiler designed for commercial, institutional and multi-unit buildings. It feeds a loop of radiators, baseboards or radiant floor, with no GHG emissions on site. It suits a \u003cstrong\u003eLaval\u003c\/strong\u003e warehouse heated by a radiant floor, a school or clinic in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, or a large \u003cstrong\u003eMontreal\u003c\/strong\u003e building heated by a central loop.\u003c\/p\u003e\n\u003ch3\u003eWhat the VoltMax does day to day\u003c\/h3\u003e\n\u003cp\u003eThe VoltMax combines relay stages, which its controller alternates, with a solid-state relay (SCR) that modulates output from 0 to 100%. According to Thermo 2000, this modulation limits peak power demand. Its Incoloy immersion elements are replaceable, and the manufacturer presents it as a clean, quiet, low-maintenance boiler.\u003c\/p\u003e\n\u003cp\u003eThe Schneider Electric controller, with a 3 in backlit display, sets the setpoint from 50 °F to 200 °F, applies outdoor reset with the included sensor and runs schedules. It communicates over BACnet IP or MS-TP, accepts an external 0-10 Vdc control and sends its alarms by email through its Ethernet port. A 2nd setpoint can also feed an indirect water heater.\u003c\/p\u003e\n\u003ch3\u003eInstallation: the steps\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate: voltage and capacity of the electrical service, existing loop, mechanical room.\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the circulator and expansion tank, which are not among the supplied parts, and the low-water cut-off if the project requires it (optional at this size).\u003c\/li\u003e\n\u003cli\u003ePlacing the 310 lb (141 kg) boiler with Thermo 2000’s clearances: 3 in at the sides and rear, 24 in at the front, 32 in above.\u003c\/li\u003e\n\u003cli\u003eConnection to the loop through the four 1 1\/2 in male NPT side connections, and piping of the factory-installed relief valve discharge.\u003c\/li\u003e\n\u003cli\u003e600 V electrical connection, with protection and conductors sized from the nameplate, under AirGreen’s RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical).\u003c\/li\u003e\n\u003cli\u003eOutdoor sensor installation, filling, purging and setting of the setpoint, schedules and alarms.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, also installing on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. Thermo 2000 warrants the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eContact us\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate for your building: the quote is in writing, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available to spread out your payments.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801688277284,"sku":"VOLTSCR60030P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR60030P3_30_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082219"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-bth-ultra-xl-bthultxl60072-72-kw-600v","title":"THERMO 2000 BTH Ultra XL BTHULTXL60072 Commercial Electric Boiler | 72 kW - 600V","description":"\u003ch2\u003eA 72 kW electric boiler that connects directly to 600 V three-phase\u003c\/h2\u003e\n\u003ch3\u003eWho the BTHULTXL60072 is for\u003c\/h3\u003e\n\u003cp\u003eIn Quebec, many commercial buildings and apartment buildings run on 600 V three-phase. Thermo 2000’s BTH Ultra XL, in its BTHULTXL60072 version, connects to that voltage without a step-down transformer. Its twelve 6 kW elements run on 347 V and deliver 72 kW, or 245,664 BTU\/h, drawing 69.3 A at full output according to the manufacturer.\u003c\/p\u003e\n\u003cp\u003eIt is a hot-water boiler: it heats a closed loop that feeds radiant floors, radiators or hydronic fan coils. It suits a manager replacing an electric boiler at the end of its life, as well as an owner adding an air-to-water heat pump or a geothermal system who wants reliable electric backup. Thermo 2000 presents it precisely as a backup boiler for a heat pump, geothermal or solar system.\u003c\/p\u003e\n\u003ch3\u003eHow it fits your building\u003c\/h3\u003e\n\u003cp\u003eThe T2 UltraSmart controller is the heart of the unit. The supplied outdoor sensor lets it adjust water temperature to the weather: the colder it is outside, the hotter the water, and heating stops in mild weather below a threshold adjustable from 0 to 105 °F. Output is modulated to demand over four stages, so the full 72 kW is not called when a fraction will do. A Boost mode, a pump purge and a backlit display round it out.\u003c\/p\u003e\n\u003cp\u003eAs for space, the steel cabinet is 23 3\/8 in wide, 12 3\/4 in deep and 23 1\/4 in high and weighs 180 lb. It mounts on the wall or sits on an optional floor stand. Water connections are 1 1\/2 in male NPT; maximum working pressure is 30 psi (207 kPa) and the water is set between 50 °F and 190 °F.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate, in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e or the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. We assess the heating load, the 600 V electrical service, the existing loop and the location. The written quote specifies the supply sizing, the loop components and the commissioning steps.\u003c\/p\u003e\n\u003cp\u003eOn installation, the unit is set in place and connected to the hot-water loop. The items supplied by Thermo 2000 are installed: 30 psi relief valve (ASME), drain valve, temperature and pressure gauge and outdoor sensor. The 600 V electrical connection is made by qualified personnel, to the codes in force. We fill the loop, purge it, test the low-water cut-off and program the controller for your building.\u003c\/p\u003e\n\u003cp\u003eA family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). The manufacturer warranty covers the tank for 10 years (limited warranty, closed-loop heating) and electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eLet’s move on your project\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us your building’s details or ask for a visit: free estimate, written quote and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available for your new BTH Ultra XL boiler.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801691455780,"sku":"BTHULTXL60072","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_BTH_ULTRA_XL_BTHULTXL60072_72_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082221"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-bth-ultra-xl-bthultxl60060-60-kw-600v","title":"THERMO 2000 BTH Ultra XL BTHULTXL60060 Commercial Electric Boiler | 60 kW - 600V","description":"\u003ch2\u003eA 60 kW commercial electric boiler for buildings on 600 V\u003c\/h2\u003e\n\u003ch3\u003eThe 60 kW size on 600 V\u003c\/h3\u003e\n\u003cp\u003eIn its BTH ULTRA XL commercial line, which the specification document names the BTH ULTRA XL 2.0, Thermo 2000 offers 48, 60 and 72 kW models on 600 V three-phase. The 60 kW model brings together twelve 5 kW, 347 V elements, controlled in four stages, and produces 204,720 BTU\/h according to the manufacturer. On 600 V, it draws 57.7 A.\u003c\/p\u003e\n\u003cp\u003eIt suits schools, community centres, municipal buildings and office buildings heated by a hot-water loop, in new construction as well as replacements. Thermo 2000 also presents it as backup for a heat pump, a geothermal or a solar system.\u003c\/p\u003e\n\u003ch3\u003eReplacing the boiler of a Laval school\u003c\/h3\u003e\n\u003cp\u003eTake a school in \u003cstrong\u003eLaval\u003c\/strong\u003e whose old floor-standing electric boiler has been feeding radiators for decades. The 60 kW BTH ULTRA XL can take its place: it sits on the floor on an optional stand or mounts on the wall, which frees up space in the mechanical room. The cabinet measures 23 3\/8 x 12 3\/4 x 23 1\/4 in (W x D x H), weighs 180 lb and holds 8 US gal (30 L) of water.\u003c\/p\u003e\n\u003cp\u003eThe connection is made in 1 1\/2 in male NPT, for a maximum working pressure of 30 psi (207 kPa); existing piping is adapted as needed. On the electrical side, Thermo 2000 gives a supply wire of up to 2\/0, and circuit protection is set according to the electrical code. The work is scheduled outside class hours or during a break.\u003c\/p\u003e\n\u003ch3\u003eControls and safety\u003c\/h3\u003e\n\u003cp\u003eThe T2 UltraSmart controller modulates output based on demand and water temperature based on the supplied outdoor sensor. It stops heating in mild weather, within a 0 to 105 °F range, and offers a Boost mode and a pump purge. Thermo 2000 includes a low water cut-off with test button and indicator lights, a 30 psi (ASME) relief valve, two limit controls and fuses; its specification document also mentions 2 in fibreglass insulation.\u003c\/p\u003e\n\u003ch3\u003eThe installation steps\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate: 600 V panel, loop, emitters and the old boiler’s nameplate.\u003c\/li\u003e\n\u003cli\u003eWritten quote: boiler, floor stand where applicable, circulator and expansion tank, which are not among the supplied items.\u003c\/li\u003e\n\u003cli\u003eRemoval of the old unit, installation of the new boiler, connection of the piping and the electrical circuit.\u003c\/li\u003e\n\u003cli\u003eFilling, purging, connecting the outdoor sensor and setting up the controller with the building manager.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years (parts and accessories). AirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 for ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eAsk for your quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. The estimate is free, the quote is in writing and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801694339364,"sku":"BTHULTXL60060","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_BTH_ULTRA_XL_BTHULTXL60060_60_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082220"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-bth-ultra-xl-bthultxl60048-48-kw-600v","title":"THERMO 2000 BTH Ultra XL BTHULTXL60048 Commercial Electric Boiler | 48 kW - 600V","description":"\u003ch2\u003e48 kW for buildings supplied at 600 V three-phase\u003c\/h2\u003e\n\u003ch3\u003eThe 48 kW BTH ULTRA XL on 600 V\u003c\/h3\u003e\n\u003cp\u003eThe BTH ULTRA XL, called the BTH ULTRA XL 2.0 in Thermo 2000’s specification document, is the manufacturer’s commercial line of electric boilers. On 600 V three-phase, it comes in 48, 60 and 72 kW. This first size produces 163,776 BTU\/h according to Thermo 2000, with 347 V elements controlled in four stages, and draws only 46.2 A.\u003c\/p\u003e\n\u003cp\u003eIt is meant for managers of apartment buildings, residences, institutional buildings and businesses supplied at 600 V that heat with a hot-water loop. Thermo 2000 also presents it as backup for a heat pump, a geothermal or a solar system.\u003c\/p\u003e\n\u003ch3\u003eA seniors’ residence in Longueuil, for example\u003c\/h3\u003e\n\u003cp\u003eIn a seniors’ residence in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, heating cannot fail. The building is supplied at 600 V, like many buildings of that size in Quebec, and each room has its own hot-water radiators. The 48 kW BTH ULTRA XL connects to a circuit whose protection is set according to the electrical code, with a supply wire of up to 2\/0 per Thermo 2000.\u003c\/p\u003e\n\u003cp\u003eFor this kind of occupant, steady heat matters. The T2 UltraSmart controller modulates output based on demand and sets the water temperature using the supplied outdoor sensor; warm weather shutdown is set within a 0 to 105 °F range. Boost mode and pump purge round out its functions. For safety, Thermo 2000 includes a low water cut-off with test button and indicator lights, a 30 psi (ASME) relief valve, two limit controls and fuses.\u003c\/p\u003e\n\u003ch3\u003eSize and connections\u003c\/h3\u003e\n\u003cp\u003eThe boiler measures 23 3\/8 x 12 3\/4 x 23 1\/4 in (W x D x H), weighs 180 lb and holds 8 US gal (30 L) of water. It mounts on the wall or sits on the floor on an optional stand. Its water connections are 1 1\/2 in male NPT; the relief valve and drain connect in 1 1\/2 in MPT reduced to 3\/4 in FPT. Maximum working pressure is 30 psi (207 kPa).\u003c\/p\u003e\n\u003ch3\u003eOur installation\u003c\/h3\u003e\n\u003cp\u003eThe on-site estimate is free: 600 V panel, loop, emitters and existing boiler. The written quote specifies the boiler, the floor stand where applicable, the circulator and the expansion tank, which are not on the list of supplied items. Our technicians schedule the work to limit the heating interruption, install the boiler, connect the piping and the circuit, fill and purge the loop, then set up the controller. Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years (parts and accessories).\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 for ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eLet’s talk about your building\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn Montreal, Laval, Longueuil, on the North Shore and on the South Shore, the estimate is free and the quote is in writing. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801695650084,"sku":"BTHULTXL60048","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_BTH_ULTRA_XL_BTHULTXL60048_48_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082220"},{"product_id":"chaudiere-electrique-thermo-2000-bth-ultra-600-36-36-kw-600v","title":"THERMO 2000 BTH Ultra 600 36 Electric Boiler | 36 kW - 600V","description":"\u003ch2\u003e36 kW on a wall: the largest BTH ULTRA size on 600 V\u003c\/h2\u003e\n\u003ch3\u003eThe top of the commercial BTH ULTRA range\u003c\/h3\u003e\n\u003cp\u003eIn the commercial version of the BTH ULTRA, powered by 600 V three-phase, the 36 kW model is the largest size. Thermo 2000 rates it at 122,832 BTU\/h, produced by six 6 kW, 347 V elements controlled in two stages. Despite that output, the boiler stays wall-mounted: 75 lb, 3 US gal of water.\u003c\/p\u003e\n\u003cp\u003eIt is aimed at buildings with a larger hot-water loop: a workshop or garage heated through the slab, a shop fitted with radiators, a small office building with hydronic baseboards. It serves new construction as well as replacements.\u003c\/p\u003e\n\u003ch3\u003eIn a Quebec workshop, garage or shop\u003c\/h3\u003e\n\u003cp\u003eTake a mechanic’s workshop in a \u003cstrong\u003eLaval\u003c\/strong\u003e industrial park, on 600 V three-phase power, with a heated slab under several bays. The BTH ULTRA 36 connects to a 50 A breaker; Thermo 2000 lists a current of 34.6 A and a suggested wire gauge of Cu 8 or Al 6. Because it hangs on the wall, it takes no floor space where vehicles and carts move around.\u003c\/p\u003e\n\u003cp\u003eA slab needs cooler water than radiators: the 50 °F to 190 °F (10 °C to 90 °C) range leaves that room, and the T2 UltraSmart controller adjusts the water temperature with the supplied outdoor sensor, using three curves (MIN, STD and MAX). It also modulates output based on demand, stops heating in mild weather and offers a Boost mode. Finally, Thermo 2000 presents the BTH ULTRA as backup for a solar or geothermal installation.\u003c\/p\u003e\n\u003ch3\u003eHow we install a commercial boiler\u003c\/h3\u003e\n\u003cp\u003eFirst, a free on-site estimate. We look at the 600 V panel, the piping, the emitters and, where applicable, the boiler being replaced. You then receive a written quote that specifies the boiler and the parts to plan for: circulator, expansion tank and accessories that are not among the items Thermo 2000 supplies.\u003c\/p\u003e\n\u003cp\u003eDuring installation, we mount the boiler, connect the inlet\/return and outlet\/supply in 1 1\/4 in NPT, install the supplied 30 psi relief valve, drain valve and temperature and pressure gauge, then make the electrical connection. Next come filling, purging, connecting the outdoor sensor and setting up the controller. Thermo 2000 covers the tank for 15 years and the electrical and mechanical components for 2 years (parts).\u003c\/p\u003e\n\u003cp\u003eA family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 for ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eNext step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFor a building in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for a free estimate and receive a written quote; \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801696665892,"sku":"BTH ULTCA 600 36","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_BTH_ULTRA_600V_36_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-thermo-2000-bth-ultra-600-30-30-kw-600v","title":"THERMO 2000 BTH Ultra 600 30 Electric Boiler | 30 kW - 600V","description":"\u003ch2\u003eA 30 kW boiler that sets the water temperature to the weather, for 600 V buildings\u003c\/h2\u003e\n\u003ch3\u003eThe BTH ULTRA 30 and the buildings it serves\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 builds the BTH ULTRA in a residential and a commercial version. This 30 kW model belongs to the latter: it runs on 600 V three-phase, with six 5 kW, 347 V elements, and delivers 102,360 BTU\/h according to the manufacturer.\u003c\/p\u003e\n\u003cp\u003eIt is found in community halls, daycares, offices and small institutional buildings heated by a hot-water loop: radiant floor, radiators or baseboards. A daycare on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e that heats its rooms through the floor, or a parish hall in \u003cstrong\u003eMontreal\u003c\/strong\u003e fitted with old radiators, are two examples of projects where it fits.\u003c\/p\u003e\n\u003ch3\u003eA controller that follows the weather\u003c\/h3\u003e\n\u003cp\u003eThe T2 UltraSmart controller is the heart of the unit. With the supplied outdoor sensor, it modulates the water temperature along three curves (MIN, STD and MAX): the colder it is outside, the hotter the water, and the other way around. When the weather turns mild, warm weather shutdown pauses the heating. The controller also modulates output based on demand and offers a Boost mode and a pump purge.\u003c\/p\u003e\n\u003cp\u003eFor a building manager, the backlit display and the presets by distribution system make seasonal adjustments simpler. Safety relies on two temperature limits: an automatic one at 208 °F (98 °C) and a manual reset one at 227 °F (108 °C).\u003c\/p\u003e\n\u003ch3\u003eIts place in a Quebec building\u003c\/h3\u003e\n\u003cp\u003e600 V three-phase power is common in Quebec’s commercial and institutional buildings. There, the BTH ULTRA 30 draws 28.9 A and calls for a 40 A breaker and a suggested wire gauge of Cu 8 or Al 6. The boiler mounts on the wall; it weighs 75 lb and holds 3 US gal of water. Its water connections are 1 1\/4 in female NPT and its maximum working pressure is 30 psi (207 kPa). Thermo 2000 also presents it as backup for a heat pump or a geothermal system.\u003c\/p\u003e\n\u003ch3\u003eAirGreen’s installation, from estimate to commissioning\u003c\/h3\u003e\n\u003cp\u003eWe start with a free estimate visit: a look at the electrical panel, the loop, the emitters and the existing boiler, if there is one. The written quote that follows specifies the boiler, the circulator, the expansion tank and the other parts to plan for.\u003c\/p\u003e\n\u003cp\u003eOn installation day, our technicians mount the boiler on the wall, install the supplied relief valve, drain valve and temperature and pressure gauge, connect the piping and the electrical circuit, then fill and purge the loop. They connect the outdoor sensor, choose the curve with you and show the building staff how to read the display. Thermo 2000 covers the tank for 15 years and the electrical and mechanical components for 2 years (parts).\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical).\u003c\/p\u003e\n\u003ch3\u003eAsk for your quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Ask for a free estimate to receive your written quote; \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801698173220,"sku":"BTH ULTCA 600 30","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_BTH_ULTRA_600V_30_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082243"},{"product_id":"chaudiere-electrique-thermo-2000-bth-ultra-600-27-27-kw-600v","title":"THERMO 2000 BTH Ultra 600 27 Electric Boiler | 27 kW - 600V","description":"\u003ch2\u003e27 kW of hot-water heating for a commercial space on 600 V power\u003c\/h2\u003e\n\u003ch3\u003eA compact commercial boiler and who it is meant for\u003c\/h3\u003e\n\u003cp\u003eThe BTH ULTRA 27 is the 27 kW commercial version of Thermo 2000’s wall-mounted electric boiler. It runs on 600 V three-phase and spreads its output over six 4.5 kW elements, controlled in two stages. Thermo 2000 rates it at 92,124 BTU\/h.\u003c\/p\u003e\n\u003cp\u003eIt is meant for owners and managers of commercial spaces, offices, clinics or workshops heated with hot water, or about to be: radiant floor, radiators or hot-water baseboards. It works for new construction as well as for replacing a boiler at the end of its life.\u003c\/p\u003e\n\u003ch3\u003eHow it fits a Quebec building\u003c\/h3\u003e\n\u003cp\u003eIn Quebec, 600 V three-phase power serves a large share of commercial and institutional buildings. On that kind of electrical service, the BTH ULTRA 27 draws 26.0 A and calls for a 40 A breaker and a suggested wire gauge of Cu 8 or Al 6. For a shop in \u003cstrong\u003eLaval\u003c\/strong\u003e or an office in \u003cstrong\u003eLongueuil\u003c\/strong\u003e whose mechanical room is already crowded, its wall-mounted format and 75 lb weight keep it off the floor.\u003c\/p\u003e\n\u003cp\u003eOn the hydronic side, it holds 3 US gal of water, connects with 1 1\/4 in female NPT fittings and works up to 30 psi (207 kPa). Its temperature range runs from 50 °F to 190 °F (10 °C to 90 °C), wide enough for a radiant floor as well as radiators, two uses Thermo 2000 lists for this series. The manufacturer also presents it as backup for a heat pump, a geothermal or a solar system.\u003c\/p\u003e\n\u003cp\u003eThe T2 UltraSmart controller handles the rest. It modulates output based on demand, adjusts the water temperature using the supplied outdoor sensor, stops heating in mild weather and offers a Boost mode. Its backlit display and presets by distribution system make commissioning simpler for the technician and the building manager alike.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eIt all starts with a free on-site estimate. We check the capacity of the 600 V panel, the condition of the loop and the existing emitters, then give you a written quote that names the boiler and the components to plan for, including the circulator and the expansion tank, which are not on Thermo 2000’s list of supplied items.\u003c\/p\u003e\n\u003cp\u003eOur crews then mount the boiler on the wall, install the supplied 30 psi relief valve and temperature and pressure gauge, connect the piping and the electrical circuit, fill and purge the loop, then set the controller and the outdoor sensor curve. As for warranty, Thermo 2000 covers the tank for 15 years and the electrical and mechanical components for 2 years (parts).\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years. We hold RBQ licence 5645-9605-01 for ventilation, refrigeration and electrical work, which lets us handle the boiler’s electrical connection.\u003c\/p\u003e\n\u003ch3\u003eLet’s talk about your building\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhether your space is in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for your free estimate: you will receive a written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801702269220,"sku":"BTH ULTCA 600 27","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_BTH_ULTRA_600V_27_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082243"},{"product_id":"chaudiere-electrique-thermo-2000-bth-ultra-600-22-22-kw-600v","title":"THERMO 2000 BTH Ultra 600 22 Electric Boiler | 22 kW - 600V","description":"\u003ch2\u003e22 kW at 600 V to back up the geothermal system or heat pump of a commercial building\u003c\/h2\u003e\n\u003ch3\u003eA boiler that serves as backup or main source\u003c\/h3\u003e\n\u003cp\u003eWhen a commercial or institutional building heats its hot water loop with a geothermal system or a heat pump, it needs reliable backup for periods of extreme cold or maintenance. Thermo 2000’s BTH ULTRA 22 plays that role, and it can also heat a business, offices or an institutional space with baseboards, radiators or radiant floors on its own.\u003c\/p\u003e\n\u003cp\u003eThis wall-mounted boiler delivers 22 kW, or 75,064 BTU\/h, on a 600 V three-phase supply. Its six 347 V elements are grouped in two stages. It belongs to the commercial BTH ULTRA line, offered at 480 V and 600 V, which Thermo 2000 designs for new installations as well as replacements.\u003c\/p\u003e\n\u003ch3\u003eControls that work with your main source\u003c\/h3\u003e\n\u003cp\u003eThe T2 UltraSmart controller modulates output over two stages based on the loop’s demand. With the supplied outdoor sensor, it sets the water temperature on one of three curves (MIN, STD, MAX); warm weather shutdown keeps the boiler at rest during periods when the main source is enough. When the cold sets in, Boost mode is available. The controller also provides a 24 V supply for the thermostat and accessories, pump purge and presets by distribution system.\u003c\/p\u003e\n\u003cp\u003eThe operating range is 50 °F to 190 °F (10 °C to 90 °C). An automatic limit at 208 °F and a manual limit at 227 °F protect the unit, and the supplied 30 psi relief valve protects the loop.\u003c\/p\u003e\n\u003ch3\u003eElectrical and connections\u003c\/h3\u003e\n\u003cp\u003eAt 600 V, the BTH ULTRA 22 draws 21.2 A. Thermo 2000 lists a 30 A breaker and copper or aluminum wire gauge 10. The boiler weighs 75 lb, holds 3 US gallons of water and connects with 1 1\/4 in female NPT fittings; two reducers are supplied.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate. We look at the main source, the loop, the electrical supply and the wall location, then give you a written quote. Our technicians install the boiler, make the 600 V electrical connection and the loop connection, fill and purge the system, then set the controller to supplement your main source. Thermo 2000 covers the tank for 15 years and electrical and mechanical components for 2 years, according to its commercial manual.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eLet’s get your project started\u003c\/h3\u003e\n\u003cp\u003eWe work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate and a written quote for your BTH ULTRA 22; \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801703285028,"sku":"BTH ULTCA 600 22","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_BTH_ULTRA_600V_22_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082243"},{"product_id":"chaudiere-electrique-thermo-2000-bth-ultra-600-18-18-kw-600v","title":"THERMO 2000 BTH Ultra 600 18 Electric Boiler | 18 kW - 600V","description":"\u003ch2\u003e18 kW in two stages to heat a 600 V building with hot water\u003c\/h2\u003e\n\u003ch3\u003eWhat the commercial BTH ULTRA 18 is\u003c\/h3\u003e\n\u003cp\u003eThermo 2000’s BTH ULTRA 18 is an 18 kW wall-mounted electric boiler, or 61,416 BTU\/h, designed for a 600 V three-phase supply. Its six 3 kW elements, rated for 347 V, are grouped in two stages. It belongs to the commercial BTH ULTRA line, offered at 480 V and 600 V, which Thermo 2000 designs for commercial and institutional buildings, in new construction as well as replacement.\u003c\/p\u003e\n\u003cp\u003eThis size is aimed at buildings whose hot water loop calls for mid-range output: the common areas of a building supplied at 600 V, a business or offices heated by radiant floors, an institutional building with radiators. It can also back up a geothermal system or a heat pump.\u003c\/p\u003e\n\u003ch3\u003eTwo stages to follow demand\u003c\/h3\u003e\n\u003cp\u003eA commercial building does not need the same heat on a January Monday morning as on an April afternoon. With two stages, the boiler does not have to run at full output when demand drops: the T2 UltraSmart controller modulates output based on the loop’s needs. The supplied outdoor sensor also lets it set the water temperature on one of three curves (MIN, STD, MAX), and warm weather shutdown rests the unit in the shoulder seasons.\u003c\/p\u003e\n\u003cp\u003eThe controller also offers a backlit display, presets by distribution system, Boost mode, pump purge and a 24 V supply for the thermostat and accessories. Two high limits, automatic at 208 °F (98 °C) and manual at 227 °F (108 °C), protect the boiler.\u003c\/p\u003e\n\u003ch3\u003eA three-phase supply that is simple to plan\u003c\/h3\u003e\n\u003cp\u003eAt 600 V, the BTH ULTRA 18 draws 17.3 A. Thermo 2000 lists a 30 A breaker and copper or aluminum wire gauge 10. Wall-mounted, it weighs 75 lb, holds 3 US gallons of water and connects with 1 1\/4 in female NPT fittings, with two reducers supplied.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate: building voltage, room in the panel, condition of the loop and wall location. You receive a written quote you can submit to the building manager or condo board. Our technicians then install the boiler, make the electrical and hydronic connections, fill and purge the loop, then set the curve and preset. Thermo 2000 covers the tank for 15 years and electrical and mechanical components for 2 years, according to its commercial manual.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eLet’s talk about your building\u003c\/h3\u003e\n\u003cp\u003eWe serve buildings in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate and receive a written quote; \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801705546020,"sku":"BTH ULTCA 600 18","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_BTH_ULTRA_600V_18_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082243"},{"product_id":"chaudiere-electrique-thermo-2000-bth-ultra-600-13-13-kw-600v","title":"THERMO 2000 BTH Ultra 600 13 Electric Boiler | 13 kW - 600V","description":"\u003ch2\u003eReplace your commercial boiler with a 13 kW, 600 V BTH ULTRA\u003c\/h2\u003e\n\u003ch3\u003eA replacement boiler for commercial and institutional buildings\u003c\/h3\u003e\n\u003cp\u003eIn many office buildings, community halls and institutional spaces, hot water heating relies on an electric boiler installed long ago. When it reaches the end of its life, Thermo 2000’s BTH ULTRA 13 offers a simple replacement: a 13 kW wall-mounted boiler, or 44,356 BTU\/h, that connects to the building’s 600 V three-phase supply.\u003c\/p\u003e\n\u003cp\u003eIt belongs to the commercial BTH ULTRA line, offered at 480 V and 600 V three phase. Thermo 2000 designs it for commercial and institutional applications, in new construction as well as replacement, to supply radiant floors, radiators or hot water baseboards. It can also back up a heat pump or a geothermal system.\u003c\/p\u003e\n\u003ch3\u003eWhat to know before replacing\u003c\/h3\u003e\n\u003cp\u003eThe first check is the voltage. This version is designed for 600 V three phase, with 347 V elements. It draws 12.5 A, and Thermo 2000 lists a 20 A breaker and copper wire gauge 12 or aluminum gauge 10. If your building is supplied at 480 V, the line includes a version for that voltage.\u003c\/p\u003e\n\u003cp\u003eThe second check is the piping. The boiler connects with 1 1\/4 in female NPT fittings, and the two supplied reducers help adapt it to the existing loop. Wall-mounted, it weighs 75 lb and holds 3 US gallons of water. Its three elements run on a single stage.\u003c\/p\u003e\n\u003ch3\u003eModern controls for an older system\u003c\/h3\u003e\n\u003cp\u003eReplacement is a chance to modernize the controls. The T2 UltraSmart controller sets the water temperature from the supplied outdoor sensor, on one of three curves (MIN, STD, MAX), and rests the boiler in warm weather. Presets by distribution system, the backlit display, Boost mode, pump purge and the 24 V supply for the thermostat make day-to-day management simpler. Two high limits, automatic at 208 °F and manual at 227 °F, protect the unit.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eAfter a free on-site estimate, you receive a written quote that describes removing the old boiler, installing the new one and the 600 V electrical connection. Our technicians then carry out the work, fill and purge the loop, and set the controller for the building. Thermo 2000 covers the tank for 15 years and electrical and mechanical components for 2 years, according to its commercial manual.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eLet’s plan the replacement\u003c\/h3\u003e\n\u003cp\u003eWe work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate and a written quote for your building; \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801725075748,"sku":"BTH ULTCA 600 13","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_BTH_ULTRA_600V_13_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-thermo-2000-bth-ultra-600-9-9-kw-600v","title":"THERMO 2000 BTH Ultra 600 9 Electric Boiler | 9 kW - 600V","description":"\u003ch2\u003eA 9 kW electric boiler that connects directly to your building’s 600 V supply\u003c\/h2\u003e\n\u003ch3\u003eWhat the commercial BTH ULTRA 9 is\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 offers its BTH ULTRA in two families: a residential line at 240 V single phase and a commercial line at 480 V and 600 V three phase. The BTH ULTRA 9 belongs to the second. It delivers 9 kW, or 30,708 BTU\/h, with three 3 kW elements designed for 347 V, and connects to the 600 V three-phase supply found in many commercial and institutional buildings.\u003c\/p\u003e\n\u003cp\u003eIt is the smallest size of the 600 V version. It is aimed at spaces where heating demand is limited: an office or showroom heated by radiant floors, a shop, a small zone of an institutional building served by its own loop, or the replacement of a low-output commercial electric boiler. It can also back up a heat pump, geothermal or solar.\u003c\/p\u003e\n\u003ch3\u003eSimple to power, easy to set\u003c\/h3\u003e\n\u003cp\u003eAt 600 V, the BTH ULTRA 9 draws only 8.7 A. Thermo 2000 lists a 15 A breaker and copper wire gauge 14 or aluminum gauge 12, which makes it easier to add to an existing commercial panel. The boiler runs on a single stage: its three elements heat together.\u003c\/p\u003e\n\u003cp\u003eThe T2 UltraSmart controller brings the convenience of modern controls. With the supplied outdoor sensor, it sets the water temperature on one of three curves (MIN, STD, MAX); warm weather shutdown rests the boiler when heat is not needed. The backlit display, presets by distribution system, Boost mode, pump purge and 24 V supply for the thermostat round out the package.\u003c\/p\u003e\n\u003cp\u003eWall-mounted, it weighs 75 lb, holds 3 US gallons of water and connects with 1 1\/4 in female NPT fittings, with two reducers supplied. Its operating range is 50 °F to 190 °F (10 °C to 90 °C).\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate: building supply, panel, heating loop and wall location. You then receive a written quote that sets out the boiler and the planned work, which makes approval by the building manager or owner easier. Our technicians install the boiler, make the 600 V electrical connection and the loop connection, fill and purge the system, then set the controller.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 covers the tank for 15 years and electrical and mechanical components for 2 years, according to its commercial manual. AirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eLet’s talk about your building\u003c\/h3\u003e\n\u003cp\u003eWe work in commercial and institutional buildings in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate and receive a written quote; \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801741263140,"sku":"BTH ULTCA 600 9","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_BTH_ULTRA_600V_9_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr480180p3-180-kw-480v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR480180P3 Commercial Electric Boiler | 180 kW - 480V 3 Phase","description":"\u003ch2\u003e180 kW on 480 V, the largest size in configuration B\u003c\/h2\u003e\n\u003ch3\u003eFor large buildings heated with hot water\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 groups its 99 to 180 kW VoltMax SCR boilers in a single configuration B. The VoltMax SCR 180 sits at the top: 180 kW, or 614,160 BTU\/h, here in its 480 V three-phase version. It is a vertical commercial hot-water electric boiler whose output modulates from 0 to 100% through solid-state relays (SCR), alongside relay stages that the controller rotates.\u003c\/p\u003e\n\u003cp\u003eIt is meant for owners of heated warehouses, workshops and large commercial buildings, as well as the engineers and contractors who design or replace their heating. Its loop can serve radiators, hot-water baseboards, a radiant floor or hydro-air coils, and an indirect water heater through its second setpoint.\u003c\/p\u003e\n\u003ch3\u003ePlanning an electrical load of this size\u003c\/h3\u003e\n\u003cp\u003eOn 480 V three-phase, the VoltMax SCR 180 draws 216.5 A. A load of this scale is prepared with the engineer or the master electrician, who size the overcurrent protection and the conductors. This is where SCR modulation makes the most sense: rather than switching its output on in blocks, the boiler follows demand, which, according to Thermo 2000, limits peak power demand. If your building’s service is 600 V, the same boiler comes in that voltage.\u003c\/p\u003e\n\u003cp\u003eTake a heated warehouse in \u003cstrong\u003eLongueuil\u003c\/strong\u003e or on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. The boiler takes up little room there: 3 in of clearance on the sides and back, 24 in in front and 32 in above. On the hydronic side, it holds 30 US gal of water and connects through four 2 1\/2 in NPT side connections; its setpoint runs from 50 °F to 200 °F. Its Schneider Electric controller communicates over BACnet IP and MS-TP, accepts a 0-10 Vdc signal and sends its alarms by email; its Incoloy immersion elements are replaceable.\u003c\/p\u003e\n\u003ch3\u003eWhat we take care of\u003c\/h3\u003e\n\u003cp\u003eThe on-site estimate is free. We examine the electrical service, the loop and the access to the mechanical room, since the boiler weighs 550 lb (250 kg). The written quote then details the boiler, the circulating pump and the expansion tank, the last two being absent from Thermo 2000’s list of supplied items.\u003c\/p\u003e\n\u003cp\u003eOur crews install the boiler, connect the piping and the 480 V circuit, fill and purge the loop, then set up the controller, the supplied outdoor sensor and, if needed, the link with the building management system. Thermo 2000’s warranty runs 10 years on the tank (limited warranty, closed-loop heating) and 2 years on the electrical and mechanical components. AirGreen, a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holds RBQ licence 5645-9605-01, which covers ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eLet’s discuss your building\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs your building in Longueuil, on the South Shore, in Montreal, Laval or on the North Shore? Ask for a free estimate and a written quote; \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801764495652,"sku":"VOLTSCR480180P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR480180P3_180_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082241"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr480165p3-165-kw-480v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR480165P3 Commercial Electric Boiler | 165 kW - 480V 3 Phase","description":"\u003ch2\u003e165 kW on 480 V, with the documentation a commercial project calls for\u003c\/h2\u003e\n\u003ch3\u003eThe VoltMax SCR 165 at a glance\u003c\/h3\u003e\n\u003cp\u003eThe VoltMax SCR 165 is Thermo 2000’s 165 kW commercial electric boiler, here in its 480 V three-phase version. The manufacturer rates it at 562,980 BTU\/h. It heats the water in a closed loop that feeds radiators, hot-water baseboards, a radiant floor or hydro-air coils, and it can serve an indirect water heater through a second setpoint.\u003c\/p\u003e\n\u003cp\u003eIt is aimed mainly at engineer-designed projects: a new industrial building, a commercial expansion, the replacement of a commercial boiler in an existing building. In those files, the boiler first has to pass the drawing review.\u003c\/p\u003e\n\u003ch3\u003eWhat the engineer and the inspector will find\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 publishes an engineering specification, an installation manual and a brochure for the VoltMax, gathered in the Documents section. The specification lists CSA C22.2 No. 165-92 and UL 834, a CSA B-51-14 tank, CRN registration and the ASME Section IV \"H\" stamp. For safety, the boiler comes with two limit controls with automatic and manual reset, a factory-installed relief valve and, since it exceeds 60 kW, a standard low-water cutoff.\u003c\/p\u003e\n\u003cp\u003eFor the control sequence, the Schneider Electric controller combines SCR modulation from 0 to 100% with rotation of the relay stages. It accepts a 0-10 Vdc signal for setpoint and output, communicates over BACnet IP and MS-TP, and adjusts the water temperature with the supplied outdoor sensor.\u003c\/p\u003e\n\u003ch3\u003eOn site, in Quebec\u003c\/h3\u003e\n\u003cp\u003eOn 480 V three-phase, the VoltMax SCR 165 draws 198.5 A; sizing the circuit is up to the engineer or the master electrician. In an industrial building in \u003cstrong\u003eLaval\u003c\/strong\u003e, for example, the vertical boiler fits with 3 in of clearance on the sides and back, 24 in in front and 32 in above. Its four 2 1\/2 in male NPT side connections, its 30 US gal of water and its 50 °F to 200 °F setpoint go straight onto the drawings. For handling, count on 550 lb (250 kg).\u003c\/p\u003e\n\u003ch3\u003eOur role on site\u003c\/h3\u003e\n\u003cp\u003eAirGreen installs the boiler to the engineer’s drawings and specification. After a free on-site estimate, we provide a written quote that specifies the circulating pump and the expansion tank, which are not on Thermo 2000’s list of supplied items. On site, our crews set the boiler in place, connect the piping and the 480 V circuit, fill and purge the loop, then commission the controller and the outdoor sensor.\u003c\/p\u003e\n\u003cp\u003eA family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, we hold RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Thermo 2000, for its part, warrants the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eLet’s prepare your project\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eEngineer, contractor or owner in Laval, Montreal, Longueuil, on the North Shore or the South Shore: ask for a free estimate and a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801778159908,"sku":"VOLTSCR480165P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR480165P3_165_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082241"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr480150p3-150-kw-480v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR480150P3 Commercial Electric Boiler | 150 kW - 480V 3 Phase","description":"\u003ch2\u003e150 kW in a vertical format, for mechanical rooms short on space\u003c\/h2\u003e\n\u003ch3\u003eWhat the VoltMax SCR 150 is and who it is for\u003c\/h3\u003e\n\u003cp\u003eIn many commercial buildings, the boiler to be replaced sits in a narrow mechanical room surrounded by piping and electrical panels. Thermo 2000’s VoltMax SCR 150 lends itself well to that setting: the manufacturer describes it as a compact, vertical boiler that needs little clearance. This 150 kW version, or 511,800 BTU\/h, runs on 480 V three-phase.\u003c\/p\u003e\n\u003cp\u003eIt is aimed at owners and managers of commercial or industrial buildings, as well as contractors preparing a replacement. Its loop can supply radiators, hot-water baseboards, a radiant floor or hydro-air coils, and its second setpoint can serve an indirect water heater.\u003c\/p\u003e\n\u003ch3\u003eIn a Quebec mechanical room\u003c\/h3\u003e\n\u003cp\u003eTake a commercial building on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e with a 480 V service. There, the VoltMax SCR 150 draws 180.4 A. Thermo 2000 requires 3 in of clearance on the sides and back, 24 in in front for service and 32 in above; no clearance is required underneath. It holds 30 US gal of water (113.5 L) and connects through four 2 1\/2 in male NPT side connections, while the relief valve and drain are 3\/4 in female NPT.\u003c\/p\u003e\n\u003cp\u003eThe compact format does not make it light, though: 550 lb (250 kg). Access therefore matters as much as space, and we check it before setting the delivery date. Once in place, the boiler modulates its output from 0 to 100% with solid-state relays, accepts a setpoint from 50 °F to 200 °F and adjusts the water temperature with the supplied outdoor sensor. Its Incoloy immersion elements are replaceable, an advantage when service work happens in a confined space.\u003c\/p\u003e\n\u003ch3\u003eThe job with AirGreen\u003c\/h3\u003e\n\u003cp\u003eThe on-site estimate is free: we measure the mechanical room and the access path, check the electrical service and examine the loop and the emitters. The written quote that follows details the boiler, the circulating pump and the expansion tank, the last two not being among the items supplied by Thermo 2000.\u003c\/p\u003e\n\u003cp\u003eOn the day, our crews set the boiler in place, connect the piping and the 480 V circuit, fill and purge the loop, then set up the Schneider Electric controller: setpoint, outdoor reset curve and, if needed, a BACnet link with the building management system. On warranty, Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eRequest an estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eOn the South Shore, in Longueuil, Montreal, Laval or on the North Shore, we come and measure your mechanical room for free. The quote is in writing and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801788612900,"sku":"VOLTSCR480150P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR480150P3_150_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082241"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr480144p3-144-kw-480v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR480144P3 Commercial Electric Boiler | 144 kW - 480V 3 Phase","description":"\u003ch2\u003eA 144 kW boiler that fits into your building’s management system\u003c\/h2\u003e\n\u003ch3\u003eWho the 480 V VoltMax SCR 144 is for\u003c\/h3\u003e\n\u003cp\u003eIn a commercial or industrial building heated with hot water, the boiler is no longer a stand-alone appliance: it has to answer to the building management system, report its alarms and follow a sequence. Thermo 2000’s VoltMax SCR 144 meets those expectations. This 144 kW version, or 491,328 BTU\/h, runs on 480 V three-phase and modulates its output from 0 to 100% with solid-state relays.\u003c\/p\u003e\n\u003cp\u003eIt is aimed at owners, building managers and mechanical contractors who are replacing a commercial electric boiler or installing a new one to the engineer’s drawings. Workshops, heated warehouses, offices, schools: any building whose loop feeds radiators, hot-water baseboards, a radiant floor or hydro-air coils.\u003c\/p\u003e\n\u003ch3\u003eA controller designed for managed buildings\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric controller, with its 3 in backlit display, communicates over BACnet IP and MS-TP. Its Ethernet port opens a web page and sends email alarms, so the manager can follow the boiler without going down to the mechanical room. An external 0-10 Vdc signal can set the setpoint and the output, and the supplied outdoor sensor provides weather compensation. The controller also rotates the stages and can serve an indirect water heater through a second setpoint.\u003c\/p\u003e\n\u003cp\u003eOn compliance, Thermo 2000’s specification lists CSA C22.2 No. 165-92 and UL 834, a CSA B-51-14 tank, CRN registration and the ASME Section IV \"H\" stamp. These references appear in the spec sheet, and your engineer can carry them into the project specification.\u003c\/p\u003e\n\u003ch3\u003e480 V and the mechanical room\u003c\/h3\u003e\n\u003cp\u003eOn 480 V three-phase, the VoltMax SCR 144 draws 173.2 A. The first check is therefore the service voltage: if your building in \u003cstrong\u003eLaval\u003c\/strong\u003e or on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e is on 600 V, the same boiler comes in that voltage. In the mechanical room, it stays compact: 3 in of clearance on the sides and back, 24 in in front, 32 in above. It holds 30 US gal of water, accepts a setpoint from 50 °F to 200 °F and weighs 550 lb (250 kg).\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eThe on-site estimate is free. We check the electrical service, the loop and the emitters, then give you a written quote that specifies the circulating pump and the expansion tank, which are not on Thermo 2000’s list of supplied items. Our crews install the boiler, connect the piping and the 480 V circuit, commission it and set up the controller; the BACnet link is coordinated with your building’s integrator.\u003c\/p\u003e\n\u003cp\u003eA family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. For its part, Thermo 2000 warrants the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eYour 480 V building\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFor a building in Montreal, Laval, Longueuil, on the North Shore or the South Shore, ask for a free estimate. You will receive a written quote, with \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801801457956,"sku":"VOLTSCR480144P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR480144P3_144_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr480132p3-132-kw-480v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR480132P3 Commercial Electric Boiler | 132 kW - 480V 3 Phase","description":"\u003ch2\u003e132 kW on 480 V for large buildings, called on only as needed\u003c\/h2\u003e\n\u003ch3\u003eAn electric boiler for heavy heating loads\u003c\/h3\u003e\n\u003cp\u003eThe VoltMax SCR 132 (manufacturer designation: VOLTMAX SCR 132-480-3 PH) is a commercial electric boiler from Thermo 2000: 132 kW, or 450,384 BTU\/h, on 480 V three-phase. It belongs to the series’ configuration B and heats the water in a closed loop, whether it serves unit heaters, a radiant floor, radiators, the coils of air handling units or an indirect water heater.\u003c\/p\u003e\n\u003cp\u003eIt is aimed at large buildings: a vehicle service garage with a radiant floor in \u003cstrong\u003eLaval\u003c\/strong\u003e, a neighbourhood shopping centre on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, an industrial building on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. In the 480 V VoltMax SCR range we offer, from 30 to 180 kW, it is a mid-range size: the right choice always comes from a heat-loss calculation.\u003c\/p\u003e\n\u003ch3\u003eOutput is a matter of metering\u003c\/h3\u003e\n\u003cp\u003eAt this size, the way the boiler draws its power matters as much as its capacity. Thermo 2000 lists 158.8 A on 480 V three-phase. Rather than switching its elements on in blocks, the VoltMax SCR modulates its output from 0 to 100% through solid-state relays (SCR), on top of its relay stages, and rotates those stages. The manufacturer points out that this modulation limits peak power.\u003c\/p\u003e\n\u003cp\u003eThe boiler can also let the building decide. A 0-10 Vdc signal imposes the setpoint or output, and BACnet IP or MS-TP communication lets the management system read its status. Without a central system, its Schneider Electric controller relies on the included outdoor sensor, schedules and a setpoint from 50 °F to 200 °F.\u003c\/p\u003e\n\u003cp\u003eOn the hydronic side, the 550 lb vertical cabinet holds 30 US gal of water, connects through four 2 1\/2 in male NPT side connections and carries a maximum working pressure of 125 psi (862 kPa) as standard. The Incoloy immersion elements are replaceable.\u003c\/p\u003e\n\u003ch3\u003eA job run by AirGreen\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate: electrical service and distribution, mechanical room, loop, emitters, access. The written quote that follows specifies the boiler and what goes with it, including the circulator and expansion tank, which Thermo 2000 does not supply.\u003c\/p\u003e\n\u003cp\u003eOur crews deliver and set the boiler in place within its clearances (24 in in front, 32 in above, 3 in on the sides and back), connect the loop and the 480 V supply, mount the outdoor sensor, fill and purge the circuit, then set up the controller, with the building’s integrator when there is one.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. AirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eLet’s talk about your project\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for your free estimate: the quote is in writing, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801815286052,"sku":"VOLTSCR480132P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR480132P3_132_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082241"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr480120p3-120-kw-480v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR480120P3 Commercial Electric Boiler | 120 kW - 480V 3 Phase","description":"\u003ch2\u003e120 kW on 480 V to supply hot-water coils and an indirect water heater\u003c\/h2\u003e\n\u003ch3\u003eA boiler for buildings with more than one need\u003c\/h3\u003e\n\u003cp\u003eThe VoltMax SCR 120 (manufacturer designation: VOLTMAX SCR 120-480-3 PH) is a commercial electric boiler from Thermo 2000: 120 kW, or 409,440 BTU\/h, on 480 V three-phase. It heats the water in a closed loop and belongs to the series’ configuration B, with 30 US gal of water in a 550 lb vertical cabinet.\u003c\/p\u003e\n\u003cp\u003eIt suits buildings that need more than space heating. A sports centre in \u003cstrong\u003eLaval\u003c\/strong\u003e with its change rooms, a community building on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, a commercial building whose air is heated by the hot-water coils of air handling units: in these cases, the same boiler can also supply an indirect water heater.\u003c\/p\u003e\n\u003ch3\u003eAir heating and domestic water, set separately\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric controller manages two setpoints. The first sets the heating loop, with outdoor reset from the included sensor, over a range of 50 °F to 200 °F. The second setpoint is reserved for the indirect water heater, and a pump contact lets domestic hot water be served with or without priority over heating.\u003c\/p\u003e\n\u003cp\u003eTo meet both, the boiler modulates its output from 0 to 100% through solid-state relays (SCR), on top of its relay stages, which it rotates. Thermo 2000 states that this modulation limits peak power. On 480 V three-phase, it draws 144.3 A.\u003c\/p\u003e\n\u003cp\u003eIn a building with a management system, it communicates over BACnet IP or MS-TP, or follows a 0-10 Vdc signal for setpoint and output. Its Ethernet port also gives access to a web page and sends alarms by email. Its maximum working pressure is 125 psi (862 kPa) as standard.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate: 480 V service, mechanical room, air handling units, hot water needs. You then receive a written quote covering the boiler and what goes around it: indirect water heater, circulators and expansion tank, which Thermo 2000 does not supply.\u003c\/p\u003e\n\u003cp\u003eOur crews deliver the boiler, set it in place with 24 in clear in front, 32 in above and 3 in on the sides and back, connect the loops to the 2 1\/2 in NPT connections, wire the 480 V supply and the outdoor sensor, then fill and purge the circuit. At commissioning, we set both setpoints and the priority to suit how the building is used.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. AirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eYour building, our estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for a free estimate: the quote is in writing and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801826558244,"sku":"VOLTSCR480120P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR480120P3_120_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr480108p3-108-kw-480v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR480108P3 Commercial Electric Boiler | 108 kW - 480V 3 Phase","description":"\u003ch2\u003e108 kW on 480 V, spread across stages that take turns\u003c\/h2\u003e\n\u003ch3\u003eA high-capacity boiler for commercial and industrial buildings\u003c\/h3\u003e\n\u003cp\u003eThe VoltMax SCR 108 (manufacturer designation: VOLTMAX SCR 108-480-3 PH) is a commercial electric boiler from Thermo 2000: 108 kW, or 368,496 BTU\/h, on 480 V three-phase. It belongs to the series’ configuration B, with a 550 lb vertical cabinet holding 30 US gal of water.\u003c\/p\u003e\n\u003cp\u003eWe suggest it for buildings where hot-water heating runs long hours: a warehouse on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e heated by unit heaters, a garage with a radiant floor in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, a commercial building whose air handling units have hot-water coils.\u003c\/p\u003e\n\u003ch3\u003eSparing the elements, day after day\u003c\/h3\u003e\n\u003cp\u003eIn a building this size, the boiler runs for much of the winter. Two mechanisms share the work. Solid-state relays (SCR) modulate output from 0 to 100% with demand, which, according to Thermo 2000, limits peak power. And the Schneider Electric controller rotates its stages, so the same elements are not always called on first.\u003c\/p\u003e\n\u003cp\u003eThese immersion elements are made of Incoloy and can be replaced. The day one of them needs changing, the job is on the element, not the boiler. Alarm codes on the screen, the web page and the Ethernet port’s email alarms help pinpoint what is going on quickly.\u003c\/p\u003e\n\u003cp\u003eThe rest of the data matters for design: 129.9 A on 480 V three-phase, four 2 1\/2 in male NPT side connections, a maximum working pressure of 125 psi (862 kPa) as standard and a setpoint adjustable from 50 °F to 200 °F. The outdoor sensor is included, and the boiler communicates over BACnet IP or MS-TP if the building has a management system.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen does\u003c\/h3\u003e\n\u003cp\u003eWe first assess the building, free of charge and on site: 480 V service, mechanical room, loop, emitters, delivery route. The written quote we then give you includes the parts missing from Thermo 2000’s list, including the circulator and expansion tank.\u003c\/p\u003e\n\u003cp\u003eOur crews deliver the boiler, set it in place within the published clearances (24 in in front, 32 in above, 3 in on the sides and back), connect the loop and the three-phase supply, mount the outdoor sensor, fill and purge the circuit. We then set up the controller with your maintenance lead.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. AirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years and holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eLet’s talk about your building\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for a free estimate: you will receive a written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801841074468,"sku":"VOLTSCR480108P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR480108P3_108_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082241"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr48099p3-99-kw-480v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR48099P3 Commercial Electric Boiler | 99 kW - 480V 3 Phase","description":"\u003ch2\u003e99 kW on 480 V: the first VoltMax SCR in format B\u003c\/h2\u003e\n\u003ch3\u003eA boiler for larger buildings\u003c\/h3\u003e\n\u003cp\u003eThe VoltMax SCR 99 (manufacturer designation: VOLTMAX SCR 99-480-3 PH) is a commercial electric boiler from Thermo 2000: 99 kW, or 337,788 BTU\/h, on 480 V three-phase. With it, the series moves to configuration B, which covers the 99 to 180 kW models. It is aimed at owners and managers of office buildings, institutional buildings and commercial buildings whose heating load goes beyond what the smaller formats cover.\u003c\/p\u003e\n\u003cp\u003eIt heats the water in a closed loop that serves radiators, a radiant floor, the hot-water coils of air handling units or an indirect water heater.\u003c\/p\u003e\n\u003ch3\u003eWhat configuration B brings\u003c\/h3\u003e\n\u003cp\u003eThe configuration B cabinet holds 30 US gal of water (113.5 L) and connects through four 2 1\/2 in male NPT side connections. Thermo 2000 lists a maximum working pressure of 125 psi (862 kPa) as standard. In a multi-storey building in \u003cstrong\u003eMontreal\u003c\/strong\u003e or \u003cstrong\u003eLaval\u003c\/strong\u003e, the height of the loop matters: we check its pressure before confirming the choice.\u003c\/p\u003e\n\u003cp\u003eThe format remains vertical and needs little room around it: 3 in on the sides and back, 24 in in front, 32 in above. It does weigh 550 lb, though, which takes planning: delivery route, doors, stairs or freight elevator.\u003c\/p\u003e\n\u003cp\u003eThe Schneider Electric controller carries the series’ functions. It modulates output from 0 to 100% through solid-state relays, on top of the relay stages (a modulation that, according to Thermo 2000, limits peak power), adjusts water temperature from the included outdoor sensor, communicates over BACnet IP or MS-TP and sends its alarms by email. On 480 V three-phase, the boiler draws 119.1 A.\u003c\/p\u003e\n\u003ch3\u003eOur work, from estimate to commissioning\u003c\/h3\u003e\n\u003cp\u003eThe estimate is free and done on site: 480 V service, panel, loop, emitters and delivery route. You then receive a written quote that includes what Thermo 2000 does not supply, such as the circulator and expansion tank.\u003c\/p\u003e\n\u003cp\u003eOur crews deliver and set the boiler in place, connect the loop in 2 1\/2 in, wire the three-phase supply and the outdoor sensor, then fill and purge the circuit. We finish by setting up the controller: setpoint, outdoor reset curve, schedules and, if needed, communication with the building system.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. AirGreen, a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eAsk for an estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFor a building in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for a free estimate: the quote is in writing and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801855525156,"sku":"VOLTSCR48099P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR48099P3_99_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082219"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr48090p3-90-kw-480v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR48090P3 Commercial Electric Boiler | 90 kW - 480V 3 Phase","description":"\u003ch2\u003e90 kW in the compact configuration A format\u003c\/h2\u003e\n\u003ch3\u003eThe VoltMax SCR 90, the largest in the compact cabinet\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 groups its VoltMax SCR boilers by configuration. Configuration A covers the 22.5 to 90 kW models, and the VoltMax SCR 90 on 480 V three-phase (manufacturer designation: VOLTMAX SCR 90-480-3 PH) is the largest of them. It delivers 90 kW, or 307,080 BTU\/h, in a 310 lb vertical cabinet that holds 11 US gal of water.\u003c\/p\u003e\n\u003cp\u003eIt is aimed at managers and owners of commercial, institutional and light industrial buildings on 480 V three-phase who need this output without having a large mechanical room. It heats a closed loop: radiators, a radiant floor, the coils of an air handling unit or an indirect water heater.\u003c\/p\u003e\n\u003ch3\u003eWhen the mechanical room is already crowded\u003c\/h3\u003e\n\u003cp\u003eThat is often what we find when replacing a boiler in an office building in \u003cstrong\u003eLongueuil\u003c\/strong\u003e or a store in \u003cstrong\u003eMontreal\u003c\/strong\u003e: the mechanical room was designed around another appliance, and pipes and ducts run everywhere. Thermo 2000 highlights the VoltMax SCR’s compact vertical design and the small clearances it needs: 3 in on the sides and back, 24 in in front, 32 in above, none at the floor.\u003c\/p\u003e\n\u003cp\u003eIts four 1 1\/2 in male NPT side connections leave a choice in how the piping is routed. The factory-installed relief valve and the drain valve connect in 3\/4 in female NPT.\u003c\/p\u003e\n\u003cp\u003eThe Schneider Electric controller modulates output from 0 to 100% through solid-state relays, on top of its stages, and Thermo 2000 states that this modulation limits peak power. On 480 V three-phase, the boiler draws 108.3 A. It adjusts water temperature from the included outdoor sensor, connects to a management system over BACnet IP or MS-TP and sends its alarms by email through its Ethernet port.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eWe first measure your mechanical room and check the 480 V service during a free on-site estimate. The written quote that follows describes the boiler, the delivery route and the parts to add, including the circulator and expansion tank, which are not on Thermo 2000’s list.\u003c\/p\u003e\n\u003cp\u003eOn installation day, our crews remove the old unit if needed, set the VoltMax SCR 90 in place, connect the loop and the three-phase supply, mount the outdoor sensor, then fill and purge the circuit before setting up the controller with you.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. AirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years; our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eHave your mechanical room measured\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for your free estimate: you will receive a written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801871614244,"sku":"VOLTSCR48090P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR48090P3_90_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082218"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr48075p3-75-kw-480v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR48075P3 Commercial Electric Boiler | 75 kW - 480V 3 Phase","description":"\u003ch2\u003e75 kW on 480 V to heat workshops, garages and radiant floors\u003c\/h2\u003e\n\u003ch3\u003eWho the 480 V VoltMax SCR 75 is for\u003c\/h3\u003e\n\u003cp\u003eThe VoltMax SCR 75 is a commercial electric boiler from Thermo 2000: 75 kW, or 255,900 BTU\/h, on 480 V three-phase (manufacturer designation: VOLTMAX SCR 75-480-3 PH). It heats the water in a closed loop and is aimed at owners of commercial or light industrial buildings that already have a 480 V service.\u003c\/p\u003e\n\u003cp\u003eWe often suggest it with a radiant floor in mind. A mechanic’s garage in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, a woodworking shop in \u003cstrong\u003eLaval\u003c\/strong\u003e, a showroom on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e: these large spaces with high ceilings heat well through the floor, and the boiler can just as easily supply radiators, the coils of an air handling unit or an indirect water heater.\u003c\/p\u003e\n\u003ch3\u003eA commercial radiant floor, set to the weather\u003c\/h3\u003e\n\u003cp\u003eA radiant floor does not like sudden swings. The outdoor sensor, supplied with the boiler, lets the Schneider Electric controller adjust water temperature to the weather, over a setpoint range of 50 °F to 200 °F. In mild weather, the water stays lukewarm; in deep cold, it rises.\u003c\/p\u003e\n\u003cp\u003eOutput follows the same principle. Solid-state relays (SCR) modulate it from 0 to 100%, on top of the relay stages, and the controller rotates its stages. Thermo 2000 points out that this modulation limits peak power, something many commercial building managers keep an eye on. On 480 V three-phase, the manufacturer lists 90.2 A.\u003c\/p\u003e\n\u003cp\u003eThe rest is designed to run without much attention: replaceable Incoloy immersion elements, a backlit screen with alarm codes, an Ethernet port with web page and email alarms, and BACnet IP \/ MS-TP if the building has a management system.\u003c\/p\u003e\n\u003ch3\u003eHow we install it\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate. We look at the 480 V service, the panel, the mechanical room and, for a radiant floor, the loop and its zones. You then receive a written quote specifying the boiler and what goes with it, including the circulator and expansion tank, which are not on the list Thermo 2000 supplies.\u003c\/p\u003e\n\u003cp\u003eOn site, our crews set the 310 lb boiler in place within its clearances (3 in on the sides and back, 24 in in front, 32 in above), connect the piping to the 1 1\/2 in NPT connections, and wire the 480 V supply and the outdoor sensor. We fill and purge the loop, then set the temperature curve with you.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. AirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, with RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eYour workshop, our quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for your free estimate. You will receive a written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801874071844,"sku":"VOLTSCR48075P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR48075P3_75_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082218"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr48072p3-72-kw-480v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR48072P3 Commercial Electric Boiler | 72 kW - 480V 3 Phase","description":"\u003ch2\u003eA 72 kW, 480 V boiler that talks to your building’s system\u003c\/h2\u003e\n\u003ch3\u003eThe 480 V VoltMax SCR 72, and the buildings it is meant for\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 designs the VoltMax SCR for commercial and institutional buildings. This 72 kW version runs on 480 V three-phase (manufacturer designation: VOLTMAX SCR 72-480-3 PH) and produces 245,664 BTU\/h. It heats a closed loop, whether the water serves a radiant floor, hot-water unit heaters, the coils of an air handling unit or an indirect water heater.\u003c\/p\u003e\n\u003cp\u003e480 V is found mostly in industrial parks and some commercial buildings. That is where this version fits: a warehouse with offices in \u003cstrong\u003eLaval\u003c\/strong\u003e, a manufacturing shop on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, a service building whose mechanical room is already wired for 480 V.\u003c\/p\u003e\n\u003ch3\u003eDesigned for building management\u003c\/h3\u003e\n\u003cp\u003eMany of these buildings have a central management system. The VoltMax SCR’s Schneider Electric controller communicates over BACnet IP or MS-TP, so the system can read its status, alarms and settings. It also accepts an external 0-10 Vdc signal to impose the temperature setpoint or the output when the building’s sequence is in charge.\u003c\/p\u003e\n\u003cp\u003eWithout a central system, the boiler manages on its own. Its included outdoor sensor adjusts water temperature to the weather; its schedules match heating to occupied hours; and its Ethernet port gives access to a web page and sends alarms by email, which helps in a building where nobody is on site at night.\u003c\/p\u003e\n\u003cp\u003eOn the electrical side, Thermo 2000 lists 86.6 A on 480 V. SCR modulation varies output from 0 to 100% through solid-state relays, which, according to the manufacturer, limits peak power; the controller also rotates its stages.\u003c\/p\u003e\n\u003ch3\u003eThe job with AirGreen\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate: 480 V service, panel, condition of the loop, access to deliver a 310 lb boiler. The written quote that follows specifies what is added to the unit, including the circulator and expansion tank, which Thermo 2000 does not supply.\u003c\/p\u003e\n\u003cp\u003eOur crews then install the boiler within the published clearances (24 in in front, 32 in above, 3 in on the sides and back), connect the 1 1\/2 in NPT piping, wire the 480 V supply, mount the outdoor sensor, then fill and purge the loop. At commissioning, we set the setpoint, the outdoor reset curve and the schedules, and we coordinate the BACnet connection with the firm that manages your system.\u003c\/p\u003e\n\u003cp\u003eThe warranty is Thermo 2000’s: 10 years on the tank (limited warranty, closed-loop heating) and 2 years on electrical and mechanical components. AirGreen, a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eYour 480 V project\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for a free estimate of your project: we give you a written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801875251492,"sku":"VOLTSCR48072P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR48072P3_72_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082219"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr48060p3-60-kw-480v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR48060P3 Commercial Electric Boiler | 60 kW - 480V 3 Phase","description":"\u003ch2\u003eA 60 kW, 480 V electric boiler, documented and certified for your commercial projects\u003c\/h2\u003e\n\u003ch3\u003eFor contractors and designers\u003c\/h3\u003e\n\u003cp\u003eWhen a new commercial building or an addition has a 480 V three-phase supply, the boiler is often chosen on paper, well before anything reaches the site. Thermo 2000’s VoltMax 60 lends itself to that. The manufacturer publishes an engineering specification, a manual and a brochure for the series, and this model delivers 60 kW, or 204,720 BTU\/h, for a current of 72.2 A.\u003c\/p\u003e\n\u003cp\u003eIt heats the water loop of a commercial or institutional building: radiant floors, radiators, hydro-air coils. A second setpoint can supply an indirect water heater, with or without domestic hot water priority.\u003c\/p\u003e\n\u003ch3\u003eWhat the boiler brings to the project\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePublished certifications: CSA C22.2 No. 165-92 and UL 834 (CSA mark for Canada and the U.S.), CSA B-51-14 tank, CRN registration, ASME Section IV “H”.\u003c\/li\u003e\n\u003cli\u003eFactory-supplied protection: control and power fuses and breakers, two limit controls (automatic and manual), installed relief valve.\u003c\/li\u003e\n\u003cli\u003eControls ready for integration: BACnet IP or MS-TP, 0-10 Vdc signal for setpoint or output, Ethernet port with web page and email alarms.\u003c\/li\u003e\n\u003cli\u003eSCR modulation from 0 to 100% which, according to Thermo 2000, limits peak power demand.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFitting the boiler into the building\u003c\/h3\u003e\n\u003cp\u003eIn a new mechanical room, space is tight. The VoltMax is vertical and compact: Thermo 2000 requires 3 in of clearance on the sides and back, 24 in at the front and 32 in above, and it can sit on the floor. It weighs 310 lb (141 kg) and holds 11 US gal of water. Its four 1 1\/2 in male NPT side connections tie it into the loop. The outdoor sensor is included and sets water temperature by the weather, between 50 °F and 200 °F (10 °C to 93 °C).\u003c\/p\u003e\n\u003cp\u003eTwo items remain to be included in the specification: the circulator and the expansion tank, which are not shipped with the boiler. The low water cut-off, for its part, is an option at 60 kW.\u003c\/p\u003e\n\u003ch3\u003eOur role on site\u003c\/h3\u003e\n\u003cp\u003eWe start with a free estimate, on site or from the plans, followed by a written quote. On site, our technicians install the boiler, connect it to the loop, extend the relief valve discharge, make the electrical connection and mount the outdoor sensor. We fill and purge the system, set up the controller and leave it ready for the management system integrator, where applicable.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eSend us your plans\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe carry out projects in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Ask for your free estimate and written quote; \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801876758820,"sku":"VOLTSCR48060P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR48060P3_60_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082219"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr48054p3-54-kw-480v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR48054P3 Commercial Electric Boiler | 54 kW - 480V 3 Phase","description":"\u003ch2\u003e54 kW of hot-water heating for only 65 A, thanks to 480 V three phase\u003c\/h2\u003e\n\u003ch3\u003eWhat the voltage changes\u003c\/h3\u003e\n\u003cp\u003eThermo 2000’s VoltMax SCR comes in several voltages. In a building with a 480 V three-phase supply, the 54 kW size draws a current of 65 A, according to the manufacturer. Conductors and protective devices are sized from that value, much lower than on 208 V or 240 V for the same output. The 480 V sizes we offer in this series range from 30 kW to 180 kW; this one produces 184,248 BTU\/h.\u003c\/p\u003e\n\u003ch3\u003eA boiler for institutional buildings\u003c\/h3\u003e\n\u003cp\u003eA school, a community centre, a place of worship: these buildings often heat with hot water, through radiators or radiant floors, and they are maintained by a small team with other duties. The VoltMax 54 is designed for them, as well as for commercial buildings of the same size.\u003c\/p\u003e\n\u003cp\u003eThe Schneider Electric controller shows alarm codes, in French or English, on a 3 in backlit display. Through its Ethernet port, it gives access to a web page and sends alarms by email. It also communicates over BACnet IP or MS-TP if the building has a management system, and accepts a 0-10 Vdc signal for setpoint or output.\u003c\/p\u003e\n\u003cp\u003eOn the heating side, the solid-state relay (SCR) varies output from 0 to 100%, complemented by relay stages that the controller rotates. The included outdoor sensor adjusts water temperature to the weather, within a setpoint of 50 °F to 200 °F (10 °C to 93 °C). A second setpoint supplies an indirect water heater, for hot water in kitchens or locker rooms.\u003c\/p\u003e\n\u003ch3\u003eBefore installation\u003c\/h3\u003e\n\u003cp\u003eThe boiler is vertical and compact. It weighs 310 lb (141 kg), holds 11 US gal of water and can be set directly on the floor. Thermo 2000 requires 3 in of clearance on the sides and back, 24 in at the front for service and 32 in above. The list of supplied parts includes the controller, outdoor sensor, fuses and breakers, two limit controls, the relief valve and the drain valve, but not the circulator or the expansion tank. Finally, the low water cut-off is an option at 54 kW.\u003c\/p\u003e\n\u003ch3\u003eAirGreen takes care of it\u003c\/h3\u003e\n\u003cp\u003eOur on-site estimate is free. We look at the water loop, the mechanical room and the 480 V electrical service, then give you a complete written quote, circulator and expansion tank included. Our technicians install the boiler, connect it to the loop through its 1 1\/2 in NPT fittings, make the electrical connection, mount the outdoor sensor, fill and purge the system and set up email alarms for your team.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eLet’s plan the work\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe install the VoltMax SCR in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Ask for your free estimate and written quote; \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801879576868,"sku":"VOLTSCR48054P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR48054P3_54_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082218"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr48045p3-45-kw-480v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR48045P3 Commercial Electric Boiler | 45 kW - 480V 3 Phase","description":"\u003ch2\u003eA 45 kW electric boiler on 480 V, delivered with its controls and safety devices\u003c\/h2\u003e\n\u003ch3\u003eThe VoltMax 45 on 480 V three phase\u003c\/h3\u003e\n\u003cp\u003eThermo 2000’s VoltMax is a hot water electric boiler intended for commercial and institutional buildings. This 45 kW model runs on 480 V three phase: it produces 153,540 BTU\/h and draws 54.1 A. It is part of the series’ configuration A, from 22.5 to 90 kW, in a range that goes up to 180 kW.\u003c\/p\u003e\n\u003cp\u003eIt suits commercial and industrial buildings supplied at 480 V that heat through a hot water loop: radiant floors, radiators or hot water coils.\u003c\/p\u003e\n\u003ch3\u003eWhat comes with the boiler\u003c\/h3\u003e\n\u003cp\u003eTo plan a job, you need to know what the manufacturer supplies. Thermo 2000 ships the VoltMax with its Schneider Electric controller, the outdoor temperature sensor, a control ON\/OFF switch, the control and power fuses and breakers, the SCR relays, two limit controls, one automatic and one manual, the factory-installed relief valve and the drain valve.\u003c\/p\u003e\n\u003cp\u003eThe controller varies the output from 0 to 100% through the SCR solid-state relays, in addition to relay stages that it rotates. Thermo 2000 points out that this modulation limits peak power demand. It also adjusts the water temperature to the weather, within a 50 °F to 200 °F setpoint range, communicates over BACnet IP or MS-TP and offers a web page and email alarms through its Ethernet port.\u003c\/p\u003e\n\u003ch3\u003eWhat is left to plan\u003c\/h3\u003e\n\u003cp\u003eThe circulator and expansion tank are not on the list of supplied parts: they are chosen for the loop. On this 45 kW size, the low water cut-off is available as an option; it is only standard above 60 kW. You also need to plan the relief valve discharge, at 3\/4 in female NPT, and a dedicated 480 V circuit.\u003c\/p\u003e\n\u003cp\u003eAs for space, the boiler connects to the loop through four 1 1\/2 in male NPT side connections. Thermo 2000 requires 24 in in front, 32 in above, 3 in on the sides and at the back, and no clearance at the floor. The unit weighs 310 lb (141 kg).\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eThe on-site estimate is free in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. We list what is supplied and what is left to plan, then give you a written quote that covers the circulator, the expansion tank and, if your project requires it, the low water cut-off.\u003c\/p\u003e\n\u003cp\u003eOur technicians then install the boiler, connect it to the loop, mount the outdoor sensor and make the electrical connection under our RBQ licence 5645-9605-01, which covers ventilation, refrigeration and electrical work. We fill, purge and program the controller before commissioning. AirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years. Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eAsk for your quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTo install a 45 kW VoltMax in your 480 V building, ask for a free estimate. The quote is written and detailed, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801880953124,"sku":"VOLTSCR48045P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR48045P3_45_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082219"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr48036p3-36-kw-480v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR48036P3 Commercial Electric Boiler | 36 kW - 480V 3 Phase","description":"\u003ch2\u003e36 kW on 480 V three phase, in a vertical boiler that fits into an already crowded mechanical room\u003c\/h2\u003e\n\u003ch3\u003eWhat the 480 V VoltMax 36 is\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 designs the VoltMax for commercial and institutional buildings heated with water. The series covers 22.5 to 180 kW, on 208 or 240 V single or three phase, and on 480 or 600 V three phase. This 36 kW model, on 480 V three phase, produces 122,832 BTU\/h and draws 43.3 A. It is part of configuration A, from 22.5 to 90 kW.\u003c\/p\u003e\n\u003cp\u003eIt is intended for workshops, warehouses and commercial spaces supplied at 480 V, where a hot water loop heats a slab, radiators or the coils of ventilation units.\u003c\/p\u003e\n\u003ch3\u003eA boiler that takes little room\u003c\/h3\u003e\n\u003cp\u003eIn many industrial buildings, the mechanical room is already taken up by panels, compressors or ventilation units. The VoltMax’s vertical design takes this into account: Thermo 2000 requires only 3 in of clearance on the sides and at the back, and none at the floor. You only need to keep 24 in clear in front and 32 in above. The unit weighs 310 lb (141 kg) and holds 11 US gal of water.\u003c\/p\u003e\n\u003cp\u003eInside, replaceable Incoloy immersion elements heat the water. SCR solid-state relays vary the output from 0 to 100%, in addition to relay stages, and Thermo 2000 points out that this modulation limits peak power demand. The manufacturer describes the boiler as quiet, clean and low maintenance.\u003c\/p\u003e\n\u003cp\u003eThe Schneider Electric controller has a 3 in backlit screen, alarm codes and an Ethernet port with a web page and email alarms. It communicates over BACnet IP or MS-TP and accepts a 0-10 Vdc signal for setpoint and output. The outdoor sensor is included, to set the water to the weather.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e or on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. We locate the boiler position, the available 480 V circuit and the loop to be served. The written quote includes the circulator and expansion tank selected, which are not among the parts supplied by Thermo 2000.\u003c\/p\u003e\n\u003cp\u003eOn installation day, we position the unit, connect it through its 1 1\/2 in male NPT connections, pipe the 3\/4 in relief valve discharge and mount the outdoor sensor. The electrical connection is made under our RBQ licence 5645-9605-01, which covers ventilation, refrigeration and electrical work. We fill the loop, purge it, program the controller and check the modulation under load.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years. Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eYour 480 V project\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTo heat your workshop or building with a 36 kW VoltMax on 480 V, ask for a free estimate. The quote is in writing, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801888719140,"sku":"VOLTSCR48036P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR48036P3_36_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082219"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr48030p3-30-kw-480v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR48030P3 Commercial Electric Boiler | 30 kW - 480V 3 Phase","description":"\u003ch2\u003e30 kW on 480 V three phase, with the certifications an engineer or inspector asks for\u003c\/h2\u003e\n\u003ch3\u003eFor buildings supplied at 480 V\u003c\/h3\u003e\n\u003cp\u003eThermo 2000’s VoltMax SCR 30-480-3 PH is a commercial electric hot-water boiler that connects directly to a 480 V three-phase supply. It delivers 30 kW, or 102,360 BTU\/h according to the manufacturer, and draws only 36.1 A at full output. It heats a loop of radiators, baseboards or radiant floor in a commercial, institutional or multi-unit building, with no GHG emissions on site.\u003c\/p\u003e\n\u003cp\u003eThe VoltMax SCR series also comes in 208 V, 240 V and 600 V. Before recommending the 480 V version, we therefore confirm your building’s actual voltage, whether it is in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e or on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eCertifications and documents\u003c\/h3\u003e\n\u003cp\u003eIn an engineered project, certifications and documentation matter as much as output. The VoltMax carries the CSA mark for Canada and the United States, to CSA C22.2 No. 165-92 and UL 834. Its tank complies with CSA B-51-14, is CRN registered and carries the ASME Section IV H stamp. Thermo 2000 publishes an engineering specification, a manual and a brochure, which you will find in the Documents section of this page.\u003c\/p\u003e\n\u003ch3\u003eOperation and controls\u003c\/h3\u003e\n\u003cp\u003eOutput is measured out by a solid-state relay (SCR) that modulates from 0 to 100%, alongside the relay stages that the controller alternates. According to Thermo 2000, this modulation limits peak power demand. The Incoloy immersion elements are replaceable.\u003c\/p\u003e\n\u003cp\u003eThe Schneider Electric controller, with a 3 in backlit display, sets the setpoint from 50 °F to 200 °F and applies outdoor reset with the included sensor. It communicates over BACnet IP or MS-TP, accepts an external 0-10 Vdc control for setpoint and output, and sends its alarms by email through its Ethernet port. A 2nd setpoint and a pump contact with or without priority allow an indirect water heater to be added.\u003c\/p\u003e\n\u003ch3\u003eAirGreen’s installation\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate, followed by a written quote. It includes the circulator and expansion tank, which are not among the supplied parts, and the low-water cut-off if the project requires it: at this size, it is optional. The boiler weighs 310 lb (141 kg), holds 11 US gal of water and needs clearances of 3 in at the sides and rear, 24 in at the front and 32 in above.\u003c\/p\u003e\n\u003cp\u003eOur technicians connect it to the loop through its four 1 1\/2 in male NPT side connections, pipe the discharge of the factory-installed relief valve and mount the outdoor sensor. The electrical connection, with protection and conductors sized from the nameplate, is made under AirGreen’s RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical).\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, also installing in \u003cstrong\u003eLongueuil\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. Thermo 2000 warrants the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eNext step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us your project’s drawings or specification, or ask for a free estimate: the quote is in writing, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available to spread out your payments.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801906020644,"sku":"VOLTSCR48030P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR48030P3_30_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082218"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-bth-ultra-xl-bthultxl48072-72-kw-480v","title":"THERMO 2000 BTH Ultra XL BTHULTXL48072 Commercial Electric Boiler | 72 kW - 480V","description":"\u003ch2\u003e72 kW of hot-water heating on 480 V three-phase, in a cabinet 23 3\/8 in wide\u003c\/h2\u003e\n\u003ch3\u003eA commercial electric boiler for buildings with a 480 V service\u003c\/h3\u003e\n\u003cp\u003eThermo 2000’s BTH Ultra XL is a hot-water electric boiler designed for commercial heating. The BTHULTXL48072 is its 72 kW size, powered by 480 V three-phase, 60 Hz. It delivers 245,664 BTU\/h from twelve 6 kW elements split into four stages, and draws 86.6 A at full output according to the manufacturer. Its elements run on 277 V.\u003c\/p\u003e\n\u003cp\u003eThis size is for owners and managers of apartment buildings and commercial spaces with a 480 V electrical service and hot-water loop heating: radiant floors, radiators or hydronic fan coils. Thermo 2000 also presents it as a backup boiler for a heat pump, geothermal or solar system.\u003c\/p\u003e\n\u003ch3\u003eA lot of output in very little space\u003c\/h3\u003e\n\u003cp\u003eFor 72 kW, the unit stays compact: 23 3\/8 in wide, 12 3\/4 in deep and 23 1\/4 in high, for 180 lb and 8 US gal of water. Thermo 2000 designs it for wall or floor mounting, on an optional stand. In many buildings in \u003cstrong\u003eMontreal\u003c\/strong\u003e and \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the mechanical room is already taken up by panels, tanks and pumps; a wall-mounted boiler of this size keeps the floor clear for service.\u003c\/p\u003e\n\u003cp\u003eThe T2 UltraSmart controller manages output according to demand instead of running all-or-nothing. With the supplied outdoor sensor, it adjusts water temperature to the weather and shuts heating off in mild weather, at a threshold adjustable from 0 to 105 °F. It offers a Boost mode and a pump purge, and its backlit display shows the unit’s status. A low-water cut-off with test button and indicator lights is built in.\u003c\/p\u003e\n\u003cp\u003eThe water temperature range runs from 50 °F to 190 °F, and the maximum working pressure is 30 psi (207 kPa). The system must be designed accordingly, which we check before proposing the unit.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eIt all starts with a free on-site estimate. We look at the building’s heating load, the condition of the hot-water loop, the capacity of the 480 V electrical service and the space available. You then receive a written quote detailing the work and the loop components to plan for.\u003c\/p\u003e\n\u003cp\u003eOn installation day, the unit is wall-mounted or set on its stand, then connected to the loop through its 1 1\/2 in male NPT connections. The supplied 30 psi relief valve, drain valve and temperature and pressure gauge are put in place, and the outdoor sensor is mounted on an outside wall. The three-phase electrical connection is made to the codes in force. We fill and purge the system, set the controller and check that each stage comes on.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). We also serve \u003cstrong\u003eLaval\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eA clear manufacturer warranty\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 covers the tank for 10 years (limited warranty, for closed-loop heating) and electrical and mechanical components for 2 years. If your building runs on 600 V instead, the same size exists in that voltage: we confirm the right version during the visit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate for the 72 kW BTH Ultra XL: we give you a written quote and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e options suited to your project.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801921028388,"sku":"BTHULTXL48072","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_BTH_ULTRA_XL_BTHULTXL48072_72_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082220"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-bth-ultra-xl-bthultxl48060-60-kw-480v","title":"THERMO 2000 BTH Ultra XL BTHULTXL48060 Commercial Electric Boiler | 60 kW - 480V","description":"\u003ch2\u003e60 kW on 480 V, as main heating or as backup for a renewable source\u003c\/h2\u003e\n\u003ch3\u003eTwo roles for one commercial boiler\u003c\/h3\u003e\n\u003cp\u003eThe BTH ULTRA XL is Thermo 2000’s commercial line of electric boilers, named the BTH ULTRA XL 2.0 in its specification document. The manufacturer presents it both as a commercial heating boiler and as backup for a heat pump, a geothermal or a solar system. The 60 kW, 480 V three-phase model brings together twelve 5 kW, 277 V elements, controlled in four stages, for 204,720 BTU\/h according to Thermo 2000.\u003c\/p\u003e\n\u003cp\u003eIt is meant for office buildings, institutional buildings, warehouses and workshops whose electrical distribution is 480 V and that heat with hot water, whether through radiators, baseboards or a radiant slab.\u003c\/p\u003e\n\u003ch3\u003eBacking up a geothermal system on the North Shore\u003c\/h3\u003e\n\u003cp\u003eThink of an institutional building on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e heated by a geothermal system connected to a hot-water loop. In deep cold, or while the geothermal system is being serviced, an electric source takes over. The 60 kW BTH ULTRA XL can fill that role; the loop connection and the controls of both sources are designed with the whole system, and we study them before proposing the setup.\u003c\/p\u003e\n\u003cp\u003eOn the electrical side, Thermo 2000 lists 72.2 A on 480 V three-phase and a supply wire of up to 2\/0; circuit protection is set according to the electrical code. On the water side, the boiler holds 8 US gal (30 L), connects with 1 1\/2 in male NPT fittings and works up to 30 psi (207 kPa). It measures 23 3\/8 x 12 3\/4 x 23 1\/4 in (W x D x H), weighs 180 lb and mounts on the wall or on the floor on an optional stand.\u003c\/p\u003e\n\u003ch3\u003eControls and safety\u003c\/h3\u003e\n\u003cp\u003eThe T2 UltraSmart controller modulates output based on demand and water temperature based on the supplied outdoor sensor, with warm weather shutdown adjustable within a 0 to 105 °F range, a Boost mode and a pump purge. For safety, Thermo 2000 includes a low water cut-off with test button and indicator lights, a 30 psi (ASME) relief valve, two limit controls and fuses.\u003c\/p\u003e\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eThe on-site estimate is free: we look at the voltage, the panel, the loop and, where applicable, the other heat source. The written quote specifies the boiler and the parts outside the list of supplied items, such as the circulator and the expansion tank. Our technicians install the boiler, connect the piping and the 480 V circuit, fill and purge the loop, then set up the controller. Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years (parts and accessories).\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 for ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eYour quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe serve Montreal, Laval, Longueuil, the North Shore and the South Shore. Ask for a free estimate to receive a written quote; \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801941279012,"sku":"BTHULTXL48060","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_BTH_ULTRA_XL_BTHULTXL48060_60_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082221"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-bth-ultra-xl-bthultxl48048-48-kw-480v","title":"THERMO 2000 BTH Ultra XL BTHULTXL48048 Commercial Electric Boiler | 48 kW - 480V","description":"\u003ch2\u003eA 48 kW commercial boiler for 480 V systems\u003c\/h2\u003e\n\u003ch3\u003eThe BTH ULTRA XL in its 480 V version\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 offers its BTH ULTRA XL commercial line, called the BTH ULTRA XL 2.0 in its specification document, from 40 to 72 kW. On 480 V three-phase, the 48 kW model is the first size: it produces 163,776 BTU\/h according to the manufacturer, with 277 V elements controlled in four stages. On this kind of system, it draws only 57.7 A.\u003c\/p\u003e\n\u003cp\u003eThis version is meant for industrial and commercial buildings whose electrical distribution is 480 V. It heats the hot-water loop that serves offices, locker rooms or work areas, and Thermo 2000 also presents it as backup for a heat pump, a geothermal or a solar system.\u003c\/p\u003e\n\u003ch3\u003eIn a South Shore plant\u003c\/h3\u003e\n\u003cp\u003eTake a plant on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e supplied at 480 V, whose offices and cafeteria are heated by a hot-water loop. When the old boiler gives out, staying on the same voltage is simpler than reworking the electrical distribution. The 48 kW BTH ULTRA XL then connects to a circuit whose protection is set according to the electrical code, with a supply wire of up to 2\/0 per Thermo 2000.\u003c\/p\u003e\n\u003cp\u003eIts size also helps in a mechanical room already filled with other equipment. The cabinet measures 23 3\/8 x 12 3\/4 x 23 1\/4 in (W x D x H), weighs 180 lb and holds 8 US gal (30 L) of water. It mounts on the wall or sits on the floor on an optional stand. The water connections are 1 1\/2 in male NPT and the maximum working pressure is 30 psi (207 kPa).\u003c\/p\u003e\n\u003ch3\u003eWhat protects the unit and the building\u003c\/h3\u003e\n\u003cp\u003eIn a plant, a boiler has to run without constant supervision. The T2 UltraSmart spreads output over four stages based on demand and follows the outdoor temperature through the supplied sensor; warm weather shutdown is set between 0 and 105 °F, and Boost mode and pump purge are added to its functions. The low water cut-off, with test button and indicator lights, is included, as is the 30 psi (ASME) relief valve. The specification document also mentions two limit controls, fuses and 2 in fibreglass insulation.\u003c\/p\u003e\n\u003ch3\u003eAn installation planned around production\u003c\/h3\u003e\n\u003cp\u003eOur estimate visit, free of charge, is used to record the system’s actual voltage, the available space and the condition of the loop. The written quote then lists everything needed: the boiler, the floor stand if you choose it, and the circulator and expansion tank, which Thermo 2000 does not supply. On the day of the work, set with you so it does not disrupt production, we mount the unit, make the hydronic and electrical connections, fill and purge the loop and set the outdoor sensor curve. Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years (parts and accessories).\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 for ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eYour plant, our estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWhether your building is in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, we come out at no charge and give you a written quote; \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801955959076,"sku":"BTHULTXL48048","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_BTH_ULTRA_XL_BTHULTXL48048_48_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082220"},{"product_id":"chaudiere-electrique-thermo-2000-bth-ultra-480-36-36-kw-480v","title":"THERMO 2000 BTH Ultra 480 36 Electric Boiler | 36 kW - 480V","description":"\u003ch2\u003eReplace or install a 36 kW boiler on a 480 V system\u003c\/h2\u003e\n\u003ch3\u003eWhat the 480 V BTH ULTRA 36 offers\u003c\/h3\u003e\n\u003cp\u003eAmong the 480 V three-phase versions of the BTH ULTRA, the 36 kW model is the largest. Six 6 kW, 277 V elements, controlled in two stages, produce 122,832 BTU\/h according to Thermo 2000. It all fits in a 75 lb wall-mounted cabinet that holds 3 US gal of water.\u003c\/p\u003e\n\u003cp\u003eThe boiler heats a closed loop that feeds a radiant floor, radiators or hot-water baseboards. It suits warehouses, showrooms, workshops and industrial buildings on 480 V power, for new construction as well as replacements. Thermo 2000 also presents it as backup for a geothermal system.\u003c\/p\u003e\n\u003ch3\u003eA replacement without changing voltage\u003c\/h3\u003e\n\u003cp\u003eIn many industrial buildings, the original electric boiler runs on 480 V. Replacing it with a unit of the same voltage avoids reworking the electrical distribution. Take a showroom in \u003cstrong\u003eLongueuil\u003c\/strong\u003e that has been heated through the floor for years: if the old boiler is 480 V and of similar output, the BTH ULTRA 36 can take its place, provided the circuit handles 43.3 A and a 60 A breaker, the values Thermo 2000 publishes.\u003c\/p\u003e\n\u003cp\u003eThe gain shows mostly in the controls. The T2 UltraSmart controller modulates output based on demand, adjusts the water temperature through the supplied outdoor sensor (MIN, STD and MAX curves) and stops heating in mild weather. Its backlit display, presets by distribution system, Boost mode and pump purge make day-to-day operation easier. For safety, an automatic limit at 208 °F (98 °C) and a manual reset limit at 227 °F (108 °C) protect the unit.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen does, step by step\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eA free on-site estimate: voltage, panel, loop, emitters and the nameplate of the current boiler.\u003c\/li\u003e\n\u003cli\u003eA written quote that specifies the boiler and the parts outside the list of supplied items, such as the circulator and the expansion tank.\u003c\/li\u003e\n\u003cli\u003eWall mounting, connection of the piping in 1 1\/4 in NPT and of the 480 V circuit, with conductor size set according to the electrical code.\u003c\/li\u003e\n\u003cli\u003eInstallation of the supplied 30 psi relief valve, drain valve and temperature and pressure gauge, then filling and purging of the loop.\u003c\/li\u003e\n\u003cli\u003eConnection of the outdoor sensor, choice of the curve and controller setup with you.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThermo 2000 covers the tank for 15 years and the electrical and mechanical components for 2 years (parts). AirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 for ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eLet’s discuss your project\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe serve Montreal, Laval, Longueuil, the North Shore and the South Shore. Ask for a free estimate: you will receive a written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801969033508,"sku":"BTH ULTCA 480 36","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_BTH_ULTRA_480V_36_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-thermo-2000-bth-ultra-480-30-30-kw-480v","title":"THERMO 2000 BTH Ultra 480 30 Electric Boiler | 30 kW - 480V","description":"\u003ch2\u003eA 30 kW boiler for buildings on 480 V three-phase power\u003c\/h2\u003e\n\u003ch3\u003eA 480 V version for industrial buildings\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 offers its BTH ULTRA wall-mounted boiler in several voltages. This 30 kW model is the commercial 480 V three-phase version: six 5 kW, 277 V elements, two stages, 102,360 BTU\/h according to the manufacturer. It heats the water in a closed loop that feeds a radiant floor, radiators or hot-water baseboards.\u003c\/p\u003e\n\u003cp\u003eIt is mainly meant for operators of industrial and commercial buildings whose electrical distribution is 480 V. A plant on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e that wants to heat its offices and locker rooms through the floor, without adding a transformer, is a good example.\u003c\/p\u003e\n\u003ch3\u003e480 V in Quebec: what to check\u003c\/h3\u003e\n\u003cp\u003eIn Quebec, most commercial buildings are supplied at 600 V; 480 V is found mainly in some industrial buildings. The first check is therefore to read the voltage on the main panel’s nameplate. On a 480 V three-phase circuit, the BTH ULTRA 30 draws 36.1 A and calls for a 50 A breaker, per Thermo 2000. Conductor size is set when the circuit is designed, according to the electrical code.\u003c\/p\u003e\n\u003cp\u003eOn the water side, the boiler holds 3 US gal, connects with 1 1\/4 in female NPT fittings and accepts a maximum working pressure of 30 psi (207 kPa). It weighs 75 lb and mounts on the wall, which keeps the mechanical room floor clear.\u003c\/p\u003e\n\u003ch3\u003eThe T2 UltraSmart controller day to day\u003c\/h3\u003e\n\u003cp\u003eThe controller shows its settings on a backlit display and offers presets by distribution system. It modulates output based on demand and adjusts the water temperature through the supplied outdoor sensor, along three curves (MIN, STD and MAX). Warm weather shutdown, Boost mode and pump purge round it out. Two limits protect against overheating: automatic at 208 °F (98 °C), manual reset at 227 °F (108 °C).\u003c\/p\u003e\n\u003ch3\u003eAirGreen handles the installation\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate: a check of the voltage and the panel, a look at the loop and the emitters. The written quote then specifies the boiler and the parts that are not among the items Thermo 2000 supplies, such as the circulator and the expansion tank.\u003c\/p\u003e\n\u003cp\u003eOn the day, our technicians mount the boiler, connect the piping and the 480 V circuit, install the 30 psi relief valve and the temperature and pressure gauge, fill and purge the loop, then set up the controller. Thermo 2000 covers the tank for 15 years and the electrical and mechanical components for 2 years (parts). AirGreen, a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holds RBQ licence 5645-9605-01 for ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eGet your quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn Montreal, Laval, Longueuil, on the North Shore and on the South Shore, the estimate is free and the quote is in writing. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801987154212,"sku":"BTH ULTCA 480 30","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_BTH_ULTRA_480V_30_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082243"},{"product_id":"chaudiere-electrique-thermo-2000-bth-ultra-480-18-18-kw-480v","title":"THERMO 2000 BTH Ultra 480 18 Electric Boiler | 18 kW - 480V","description":"\u003ch2\u003e18 kW at 480 V to heat a radiant slab or a commercial hot water loop\u003c\/h2\u003e\n\u003ch3\u003eWhat the 480 V BTH ULTRA 18 is\u003c\/h3\u003e\n\u003cp\u003eThermo 2000’s BTH ULTRA 18 comes in several voltages; this one is the commercial version at 480 V three phase. It delivers 18 kW, or 61,416 BTU\/h, through three 6 kW elements designed for 277 V, which heat together on a single stage. Wall-mounted, it weighs 75 lb, holds 3 US gallons of water and connects with 1 1\/4 in female NPT fittings.\u003c\/p\u003e\n\u003cp\u003eThis model suits commercial and institutional buildings supplied at 480 V. Think of a workshop or commercial garage with a heated slab, a business or showroom heated through the floor, an institutional space with radiators. Thermo 2000 designs it for new construction as well as replacement, and as backup for a geothermal system or a heat pump.\u003c\/p\u003e\n\u003ch3\u003eBuilt to last\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 describes the BTH ULTRA as compact, robust and easy to maintain, with no on-site GHG emissions. In a workshop or garage, it is a unit you can forget about: mounted on the wall, it leaves the floor clear. Two high limits, automatic at 208 °F (98 °C) and manual at 227 °F (108 °C), protect the boiler, and the supplied 30 psi relief valve protects the loop.\u003c\/p\u003e\n\u003cp\u003eThe T2 UltraSmart controller sets the water temperature from the supplied outdoor sensor, on one of three curves (MIN, STD, MAX). Warm weather shutdown rests the boiler when heat is not needed, and Boost mode remains available. The backlit display, presets by distribution system, pump purge and 24 V supply for the thermostat round out the package.\u003c\/p\u003e\n\u003ch3\u003eThe supply to plan\u003c\/h3\u003e\n\u003cp\u003eAt 480 V, the boiler draws 21.6 A. Thermo 2000 lists a 30 A breaker and copper or aluminum wire gauge 10. If your building is supplied at 600 V, the commercial BTH ULTRA line offers a version for that voltage: we confirm the voltage on site before choosing.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eAfter a free on-site estimate, you receive a written quote that describes the boiler, the 480 V electrical connection and the work on the loop. Our technicians mount the boiler, connect it to the loop (two reducers supplied) and to the electrical circuit, fill and purge the system, then set the controller for your floor or radiators. Thermo 2000 covers the tank for 15 years and electrical and mechanical components for 2 years, according to its commercial manual.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eNext step\u003c\/h3\u003e\n\u003cp\u003eWe work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate and a written quote for your building; \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801996329252,"sku":"BTH ULTCA 480 18","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_BTH_ULTRA_480V_18_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082243"},{"product_id":"chaudiere-electrique-thermo-2000-bth-ultra-480-15-15-kw-480v","title":"THERMO 2000 BTH Ultra 480 15 Electric Boiler | 15 kW - 480V","description":"\u003ch2\u003eA 15 kW electric boiler for commercial buildings supplied at 480 V\u003c\/h2\u003e\n\u003ch3\u003eWhat the 480 V BTH ULTRA 15 is\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 offers its commercial BTH ULTRA line in two three-phase voltages, 480 V and 600 V. This 15 kW model, or 51,180 BTU\/h, is the 480 V version: its three 5 kW elements are designed for 277 V and heat together on a single stage. It is a 75 lb wall-mounted boiler that holds 3 US gallons of water and connects with 1 1\/4 in female NPT fittings.\u003c\/p\u003e\n\u003cp\u003eIt is aimed at commercial and institutional buildings supplied at 480 V: a business or offices heated by radiant floors, an institutional space with hot water baseboards or radiators, or the replacement of a commercial boiler of the same voltage. Thermo 2000 designs it for new installations as well as replacements, and as backup for a heat pump, geothermal or solar.\u003c\/p\u003e\n\u003ch3\u003eVoltage first\u003c\/h3\u003e\n\u003cp\u003eBefore talking about output, the voltage must be confirmed. A boiler designed for 480 V does not suit a 600 V building, and the reverse is also true. During the estimate, we check your building’s supply and, if needed, point you to the 600 V version of the line.\u003c\/p\u003e\n\u003cp\u003eOnce the voltage is confirmed, the supply is simple to plan. The BTH ULTRA 15 draws 18.0 A at 480 V; Thermo 2000 lists a 30 A breaker and copper or aluminum wire gauge 10.\u003c\/p\u003e\n\u003ch3\u003eControls that follow the weather\u003c\/h3\u003e\n\u003cp\u003eEven on a single stage, the boiler benefits from the T2 UltraSmart controller. With the supplied outdoor sensor, it sets the water temperature on one of three curves (MIN, STD, MAX), and warm weather shutdown rests the unit when heat is not needed. Presets by distribution system, a backlit display, Boost mode, pump purge and a 24 V supply for the thermostat round out the package. Two high limits, automatic at 208 °F and manual at 227 °F, protect the boiler.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eThe free on-site estimate covers the voltage, panel, loop and wall location. You then receive a written quote. Our technicians install the boiler, make the 480 V electrical connection and the loop connection (two reducers are supplied), fill and purge the system, then set the controller. Thermo 2000 covers the tank for 15 years and electrical and mechanical components for 2 years, according to its commercial manual.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eLet’s talk about your building\u003c\/h3\u003e\n\u003cp\u003eWe work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate: we confirm the voltage and output, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67802010190116,"sku":"BTH ULTCA 480 15","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_BTH_ULTRA_480V_15_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr24075p3-75-kw-240v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR24075P3 Commercial Electric Boiler | 75 kW - 240V 3 Phase","description":"\u003ch2\u003e75 kW on 240 V three-phase to heat the building and its hot water\u003c\/h2\u003e\n\u003ch3\u003eThe largest 240 V three-phase VoltMax SCR in our range\u003c\/h3\u003e\n\u003cp\u003eThe VoltMax SCR 75 (manufacturer designation: VOLTMAX SCR 75-240-3 PH) is a 75 kW commercial electric boiler, or 255,900 BTU\/h. Among the 240 V three-phase VoltMax SCR models we offer, it is the largest size. It is aimed at owners and managers of apartment buildings, small commercial buildings and institutional buildings that already have a 240 V three-phase service.\u003c\/p\u003e\n\u003cp\u003eLike every VoltMax SCR, it heats the water in a closed loop. That water can run through radiators, a radiant floor or the coils of an air handling unit. What makes it useful in a rental building is that it can also take care of an indirect water heater.\u003c\/p\u003e\n\u003ch3\u003eOne appliance for heating and the indirect water heater\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric controller offers a second setpoint, reserved for the indirect water heater, and a pump contact with or without domestic hot water priority. In practice, a building in \u003cstrong\u003eLaval\u003c\/strong\u003e or \u003cstrong\u003eLongueuil\u003c\/strong\u003e that heats its apartments with hot water can also produce domestic water from the same boiler, through an indirect tank ordered separately.\u003c\/p\u003e\n\u003cp\u003eFor heating, the included outdoor sensor adjusts water temperature to the weather, over a setpoint range of 50 °F to 200 °F. Output follows demand from 0 to 100% through solid-state relays (SCR), on top of the relay stages; according to Thermo 2000, this modulation limits peak power.\u003c\/p\u003e\n\u003cp\u003eIt does, however, need an electrical service to match: the manufacturer lists 180.4 A on 240 V three-phase. We compare that value with the building’s actual capacity before proposing this model.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eThe estimate is free and done on site. We note the electrical service, the panel, the loop, the radiators or floor, and the occupants’ hot water needs. You then receive a written quote naming the boiler, the indirect water heater if there is one, the circulator and the expansion tank, the latter two not being on Thermo 2000’s list of supplied components.\u003c\/p\u003e\n\u003cp\u003eOn the day, we set the 310 lb boiler in place within its clearances (3 in on the sides and back, 24 in in front, 32 in above), connect the loop to the 1 1\/2 in NPT side connections, wire the three-phase supply and the outdoor sensor, then set both setpoints and the priority. The loop is filled and purged before the system goes back into service.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer’s warranty covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. A family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eAsk for your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBuildings in Montreal, Laval, Longueuil, on the North Shore and on the South Shore: the estimate is free, the quote is in writing and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67802027819300,"sku":"VOLTSCR24075P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR24075P3_75_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082219"}],"url":"https:\/\/airgreen.ca\/en\/collections\/chaudieres-electriques-commerciales-installation-a-montreal-laval-longueuil-rive-sud-et-rive-nord.oembed","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}