{"title":"Hydronic Heating | Installation in Montreal, Laval, Longueuil, South Shore and North Shore","description":null,"products":[{"product_id":"chauffe-eau-indirect-thermo-2000-turbomax30-3-30-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"THERMO 2000 TURBOMAX30-3 Indirect Water Heater (30 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eA compact 30 US gallon indirect water heater for small homes and condos heated by an electric boiler\u003c\/h2\u003e\n\u003cp\u003eIn a condo, a bungalow or a townhouse heated by an \u003cstrong\u003eelectric boiler\u003c\/strong\u003e and radiant floors, the mechanical space often comes down to a closet. The \u003cstrong\u003eThermo 2000 TurboMax 30-3 indirect water heater\u003c\/strong\u003e was designed for this kind of place: a \u003cstrong\u003e30 US gallon\u003c\/strong\u003e tank only 18 in in diameter, with a \u003cstrong\u003ehigh-exchange-capacity copper coil system\u003c\/strong\u003e that heats domestic water instantly, according to the manufacturer. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThis model lets the electric boiler that already heats the home take over hot water production, and frees the space taken by a separate electric water heater.\u003c\/p\u003e\n\n\u003ch3\u003eA format designed for small spaces\u003c\/h3\u003e\n\u003cp\u003eAt 59 3\/4 in high, 18 in in diameter and 170 lb, the TurboMax 30-3 fits where a wider tank will not: a service closet, a corner of the laundry room, a condo’s mechanical room. It is installed beside the boiler, which keeps the piping short and simple. We still check the clearances needed for the fittings, the relief valve and the drain valve, as well as access to a drain or a drain pan.\u003c\/p\u003e\n\n\u003ch3\u003eHow the TurboMax produces hot water\u003c\/h3\u003e\n\u003cp\u003eThe TurboMax is an indirect water heater: it is connected to the electric boiler, whose heating water supplies its energy. According to Thermo 2000, its high-exchange-capacity copper coil system heats water instantly: domestic water is heated as it passes through the exchanger. The difference between first-hour output and continuous output, in the table below, corresponds to the energy already stored in the tank at the start of use.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 30 US gallons\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e copper coils, exchange surface of 19.6 sq. ft.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDomestic hot water at 110 °F:\u003c\/strong\u003e maximum exchange capacity of 380,000 BTU\/h (111 kW); 683 US GPH first hour; 653 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDomestic hot water at 140 °F:\u003c\/strong\u003e maximum exchange capacity of 270,000 BTU\/h (79 kW); 338 US GPH first hour; 326 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDomestic hot water at 160 °F:\u003c\/strong\u003e maximum exchange capacity of 180,000 BTU\/h (53 kW); 186 US GPH first hour; 181 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConditions:\u003c\/strong\u003e domestic cold water at 40 °F and boiler water at 180 °F\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum domestic hot water flow:\u003c\/strong\u003e 9 gpm\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum pressure:\u003c\/strong\u003e 150 psi\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e potable water 1 1\/4 in male sweat; boiler 1 1\/4 in NPT male\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e height 59 3\/4 in, diameter 18 in\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 170 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eMaximum exchange capacity and your boiler’s real output\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer’s figures are impressive for a 30 US gallon tank, and they need to be read correctly. They show what the exchanger can transfer at most, when the boiler supplies it with up to 380,000 BTU\/h (111 kW) for water at 110 °F. A residential electric boiler supplies much less. With it, the TurboMax 30-3 heats water the same way, but its continuous output is limited by the boiler’s capacity, not by the exchanger.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 also specifies that these values must be reduced for high-temperature and continuous-flow applications. During the assessment, we start from your boiler’s capacity and your habits to tell you what you will really get at the tap, rather than quoting the best line of the table.\u003c\/p\u003e\n\n\u003ch3\u003eWho the TurboMax 30-3 is for\u003c\/h3\u003e\n\u003cp\u003eThis model suits a couple or a small family in a condo or a compact home heated by an electric boiler. It is also relevant in a renovation project where baseboards are replaced by radiant floors and where heating and hot water are to be grouped in a single room. For a home with several bathrooms or a large tub, a larger TurboMax is more appropriate; we compare the options with you.\u003c\/p\u003e\n\n\u003ch3\u003eFlow, temperature and comfort\u003c\/h3\u003e\n\u003cp\u003eThe maximum domestic hot water flow of the TurboMax 30-3 is 9 gpm. It is the value that guides the piping diameter and the number of fixtures that can be supplied at the same time; we take it into account in the design. We generally recommend adding a \u003cstrong\u003ethermostatic mixing valve\u003c\/strong\u003e at the outlet, especially if water is produced at 140 °F or more: it delivers a safe, steady temperature at the taps. The control is connected to the electric boiler with \u003cstrong\u003ehot water priority\u003c\/strong\u003e, so the boiler devotes a few minutes to it before returning to heating.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s warranty\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 offers a \u003cstrong\u003e15-year residential warranty\u003c\/strong\u003e and a \u003cstrong\u003e10-year commercial warranty\u003c\/strong\u003e, as well as a \u003cstrong\u003e2-year warranty on mechanical components\u003c\/strong\u003e. The terms that apply to your installation are confirmed in writing with the quote.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation of the Thermo 2000 TurboMax 30-3 by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work, which allows us to handle the piping as well as the electrical controls. Our work includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eassessment of the electric boiler, its capacity and the available space;\u003c\/li\u003e\n\u003cli\u003eremoval and disposal of the old water heater;\u003c\/li\u003e\n\u003cli\u003econnecting the potable water in 1 1\/4 in, with thermostatic mixing valve and shut-off valves;\u003c\/li\u003e\n\u003cli\u003econnecting to the boiler in 1 1\/4 in, with circulator or zone valve, check valve and air vent;\u003c\/li\u003e\n\u003cli\u003ethe relief valve and its discharge pipe to a drain;\u003c\/li\u003e\n\u003cli\u003ewiring the control and setting hot water priority;\u003c\/li\u003e\n\u003cli\u003ecommissioning and maintenance advice, including periodic draining through the tank drain valve.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, Verdun, Saint-Lambert, Brossard, Boisbriand, Mascouche and the entire \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. Free on-site estimate, written quote and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free quote for the Thermo 2000 TurboMax 30-3.\u003c\/strong\u003e A photo of your boiler, its rating plate and the planned closet is all we need to confirm feasibility.\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801417285924,"sku":"TURBOMAX30-3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_THERMO_2000_TURBOMAX30_3_30_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082278"},{"product_id":"chauffe-eau-indirect-bradford-white-ss-40-l-38-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"BRADFORD WHITE SS-40-L Indirect Water Heater (38 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eA compact stainless steel indirect tank that draws your hot water from the electric boiler\u003c\/h2\u003e\n\u003cp\u003eIf your home is heated by an \u003cstrong\u003eelectric boiler\u003c\/strong\u003e that feeds radiators or a radiant floor, that same boiler can also produce your domestic hot water. The \u003cstrong\u003eBradford White SS-40-L indirect water heater\u003c\/strong\u003e is designed for exactly that: its \u003cstrong\u003e38 US gallon (31 imperial gallon, 142 L)\u003c\/strong\u003e tank contains a stainless steel coil through which the boiler water flows. The potable water warms up in contact with the coil, without ever mixing with the heating water. AirGreen installs and connects this tank in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is the most compact of the Bradford White SS indirect tanks we offer. At 38 1\/4 in. tall and 91 lb empty, it easily finds a place next to a wall-hung boiler, in a small mechanical room or in the utility closet of a townhouse.\u003c\/p\u003e\n\u003ch3\u003eHow an indirect water heater works\u003c\/h3\u003e\n\u003cp\u003eAn indirect water heater has no electric element and no heat source of its own. When the tank sensor calls for heat, the boiler sends its hot water through the internal coil; the heat passes through the stainless steel wall and warms the domestic water around it. Once the set point is reached, the boiler goes back to its heating zones. In most installations, domestic hot water gets priority over space heating during these short periods, which allows a quick recovery after heavy use.\u003c\/p\u003e\n\u003cp\u003eThis operation gives the SS-40-L a particular trait: its first-hour rating far exceeds its volume, because the boiler recharges the reserve while you are drawing water. A small indirect tank can therefore keep up with a demand that an electric tank of similar size would struggle to sustain, provided the boiler has the required output.\u003c\/p\u003e\n\u003ch3\u003eWhich homes this size is designed for\u003c\/h3\u003e\n\u003cp\u003eThe SS-40-L suits a couple or a small family living in a house, a semi-detached home or a townhouse already equipped with an electric boiler. It is also useful when space is tight: a finished basement where the mechanical room has been kept to a minimum, or a townhouse-style condo with just a utility closet. For a larger family or several bathrooms used at the same time, we compare it with the larger SS sizes before making a recommendation.\u003c\/p\u003e\n\u003ch3\u003eManufacturer data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 38 US gallons, 31 imperial gallons, 142 L.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFirst-hour rating (AHRI):\u003c\/strong\u003e 237 gal\/h (897 L\/h), with boiler water at 180 °F (82 °C).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eContinuous draw:\u003c\/strong\u003e 209 gal\/h at 135 °F (791 L\/h at 57 °C).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eStandby heat loss:\u003c\/strong\u003e 0.6 °F\/h (0.33 °C\/h).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMinimum heat source input for these ratings:\u003c\/strong\u003e 135,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMinimum heat source flow:\u003c\/strong\u003e 14.0 gal\/min (53.0 L\/min).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum boiler supply temperature:\u003c\/strong\u003e 240 °F (116 °C).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e single-wall stainless steel coil, 1 in. (25 mm) outside diameter.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e potable water in 3\/4 in. NPT; boiler through 1 in. (25 mm) female NPT fittings at the front, supply and return.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions and weight:\u003c\/strong\u003e height of 38 1\/4 in. (972 mm), diameter of 24 in. (610 mm), 91 lb (41 kg).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eReading these ratings with an electric boiler\u003c\/h3\u003e\n\u003cp\u003eBradford White specifies that these ratings were obtained with the stated heat source input and flow, and with boiler water at 180 °F (82 °C). The manufacturer adds that different conditions produce different results. This is an important point in an electrically heated home: many residential electric boilers have an output below 135,000 BTU\/h. The tank then works very well, but the actual first-hour rating and continuous draw are lower than the published values. During the assessment, we look at your boiler's output, its set point and its winter heating load to give you a realistic expectation rather than a catalogue figure.\u003c\/p\u003e\n\u003ch3\u003e444 stainless steel: no lining to protect\u003c\/h3\u003e\n\u003cp\u003eThe tank and heat exchanger of the SS-40-L are made of \u003cstrong\u003e444 ferritic stainless steel\u003c\/strong\u003e, a chromium, molybdenum and titanium alloy. There is therefore no glass lining inside: the steel itself resists corrosion. The \u003cstrong\u003elow-restriction brass drain valve\u003c\/strong\u003e, with a tamper-resistant design, makes maintenance flushing easier. The model's performance ratings are AHRI certified.\u003c\/p\u003e\n\u003ch3\u003eIntegration with the heating system\u003c\/h3\u003e\n\u003cp\u003eThe 1 in. NPT boiler connections are located at the front of the tank, which simplifies the piping when the unit sits next to the boiler. The manufacturer allows boiler water up to 240 °F (116 °C), a limit well above the usual working temperatures of a residential electric boiler. Because the coil is single-wall, the fluid circulating in the heating loop must meet the applicable plumbing requirements; if your system contains antifreeze, we check its compatibility before connecting the tank. The SS-40-L is connected to a dedicated zone, with its own circulator or zone valve depending on how your system is set up.\u003c\/p\u003e\n\u003ch3\u003eA reserve that holds its heat\u003c\/h3\u003e\n\u003cp\u003eThe published standby heat loss of the SS-40-L is 0.6 °F per hour (0.33 °C\/h). When nobody is using hot water, the reserve temperature therefore drops slowly, and the boiler does not need to restart often to maintain it. In a cool basement, we also insulate the accessible hot water piping to limit losses on the way to the taps.\u003c\/p\u003e\n\u003ch3\u003eManufacturer's warranty\u003c\/h3\u003e\n\u003cp\u003eBradford White sets different warranty terms depending on whether the unit is installed in a residence or in a commercial application. We tell you in writing, with the quote, which coverage applies to your installation.\u003c\/p\u003e\n\u003ch2\u003eInstallation of the SS-40-L with your electric boiler, by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company established in Montreal, active for more than fifteen years and holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). After a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, we give you a \u003cstrong\u003ewritten quote\u003c\/strong\u003e. Installation includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eassessing the existing boiler: output, set point, zones and circulators;\u003c\/li\u003e\n\u003cli\u003echoosing the location near the boiler and checking the service clearance;\u003c\/li\u003e\n\u003cli\u003edraining and removing the old water heater, where applicable;\u003c\/li\u003e\n\u003cli\u003econnecting the coil to the boiler, supply and return in 1 in. NPT, with the required zone components;\u003c\/li\u003e\n\u003cli\u003econnecting the domestic cold and hot water in 3\/4 in. NPT and installing the relief valve with its discharge line;\u003c\/li\u003e\n\u003cli\u003ewiring the zone control and setting hot water priority;\u003c\/li\u003e\n\u003cli\u003ecommissioning, purging air from the loop and setting the temperature;\u003c\/li\u003e\n\u003cli\u003emaintenance advice for the tank and the boiler.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSimple maintenance\u003c\/h3\u003e\n\u003cp\u003eA stainless steel indirect tank needs little maintenance. A partial flush once a year, through the brass drain valve, removes the sediment that settles at the bottom. We also check the operation of the relief valve, the tightness of the fittings and the set temperature. Since the tank depends on the boiler, the boiler's annual maintenance is done during the same appointment.\u003c\/p\u003e\n\u003ch3\u003eService area\u003c\/h3\u003e\n\u003cp\u003eWe work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, Brossard, Châteauguay, Sainte-Julie, Boisbriand, Saint-Eustache and everywhere on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. The project can be paid in instalments through our \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the Bradford White SS-40-L.\u003c\/strong\u003e A photo of your boiler, its nameplate and the available space helps us prepare the visit.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":67801417318692,"sku":"SS-40-L","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_BRADFORD_WHITE_POWERSTOR_SS_40_L_38_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082267"},{"product_id":"chauffe-eau-indirect-bradford-white-ss-50-l-50-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"BRADFORD WHITE SS-50-L Indirect Water Heater (50 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eOne electric boiler for the whole family's heating and hot water\u003c\/h2\u003e\n\u003cp\u003eIn a home heated by an \u003cstrong\u003eelectric boiler\u003c\/strong\u003e and a radiant floor or hot water radiators, it makes sense to give that boiler the domestic hot water as well. The \u003cstrong\u003eBradford White SS-50-L indirect water heater\u003c\/strong\u003e acts as the buffer tank between the boiler and your taps: it holds \u003cstrong\u003e50 US gallons (42 imperial gallons, 189 L)\u003c\/strong\u003e of potable water, heated by a stainless steel coil connected to the heating loop. It is a size well suited to a family home with two bathrooms. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhy connect hot water to the boiler\u003c\/h3\u003e\n\u003cp\u003eA conventional electric tank has its own elements and its own circuit. An indirect tank, on the other hand, has no element at all: it uses the output of the boiler already installed for heating. The result shows mostly in the amount of hot water available. Since the boiler recharges the tank while you draw water, the first-hour rating of the SS-50-L is well above its volume, which helps a family run showers, a bath and the dishwasher back to back in the morning and evening.\u003c\/p\u003e\n\u003cp\u003eThe stainless steel tank and coil add another benefit: the vessel has no internal lining that could crack over time. It is a durable choice for a home you plan to keep for a long time.\u003c\/p\u003e\n\u003ch3\u003eSS-50-L specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 50 US gallons, 42 imperial gallons, 189 L.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAHRI first-hour rating:\u003c\/strong\u003e 269 gal\/h (1,018 L\/h), boiler at 180 °F (82 °C).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eContinuous draw:\u003c\/strong\u003e 229 gal\/h at 135 °F, or 867 L\/h at 57 °C.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eStandby loss:\u003c\/strong\u003e 0.5 °F\/h (0.27 °C\/h).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat source required for these ratings:\u003c\/strong\u003e at least 145,000 BTU\/h and 14.0 gal\/min (53.0 L\/min).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBoiler water:\u003c\/strong\u003e maximum supply temperature of 240 °F (116 °C).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e single-wall stainless steel coil, 1 in. (25 mm) outside diameter.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaterial:\u003c\/strong\u003e tank and heat exchanger in 444 ferritic stainless steel.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e potable water in 3\/4 in. NPT; boiler in 1 in. (25 mm) female NPT, at the front.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeight:\u003c\/strong\u003e 48 in. (1,219 mm); \u003cstrong\u003ediameter:\u003c\/strong\u003e 24 in. (610 mm); \u003cstrong\u003eweight:\u003c\/strong\u003e 103 lb (47 kg).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWith a radiant floor or radiators\u003c\/h3\u003e\n\u003cp\u003eA radiant floor runs on lukewarm water, whereas the coil of an indirect tank needs much hotter water to transfer its heat well. Most systems handle this difference with a mixing valve or a control that temporarily raises the boiler temperature when the tank calls for heat. With hot water radiators, the boiler already works at a higher temperature and the integration is more direct. In both cases, we examine the existing configuration before proposing the connection, so that space heating and hot water do not interfere with each other.\u003c\/p\u003e\n\u003ch3\u003eWhat a continuous draw of 229 gal\/h means\u003c\/h3\u003e\n\u003cp\u003eThe continuous draw indicates the amount of water at 135 °F (57 °C) the tank can supply on an ongoing basis when the boiler sends it the output and flow specified by the manufacturer. This figure explains why a mid-sized indirect tank keeps up very well with back-to-back showers. Bradford White points out, however, that its certifications are obtained under specific conditions, with boiler water at 180 °F, and that different conditions give different results.\u003c\/p\u003e\n\u003ch3\u003eSizing the boiler and the tank together\u003c\/h3\u003e\n\u003cp\u003eTo reach the published ratings, the heat source must supply at least 145,000 BTU\/h and a flow of 14.0 gal\/min. Many residential electric boilers have a lower output; the SS-50-L then works normally, but with slower recovery than the values in the table. That is why we never choose the tank on its own: we look at the boiler's output, the home's heating load in extreme cold and your usage habits, then explain what you can really expect.\u003c\/p\u003e\n\u003ch3\u003eConstruction and accessories\u003c\/h3\u003e\n\u003cp\u003eThe 444 stainless steel alloy, with chromium, molybdenum and titanium, forms both the tank and the coil. The boiler connections are at the front, a practical layout when the tank is installed next to the boiler. The \u003cstrong\u003elow-restriction brass drain valve\u003c\/strong\u003e, with a tamper-resistant design, makes flushing faster. With a standby loss of 0.5 °F\/h, the stored water holds its heat well between uses. The model's ratings are AHRI certified.\u003c\/p\u003e\n\u003ch3\u003eManufacturer's warranty\u003c\/h3\u003e\n\u003cp\u003eBradford White's warranty terms vary depending on whether the tank is used in a residence or in a commercial application. The coverage that applies to your project is stated in your written quote.\u003c\/p\u003e\n\u003ch2\u003eInstallation of the Bradford White SS-50-L by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company established in Montreal and active for more than fifteen years. Our electrical work is done under RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). Everything starts with a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e and a \u003cstrong\u003ewritten quote\u003c\/strong\u003e. For the SS-50-L, installation includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eanalysing the electric boiler, its zones and its control;\u003c\/li\u003e\n\u003cli\u003edraining, disconnecting and removing the old electric tank;\u003c\/li\u003e\n\u003cli\u003esetting the SS-50-L near the boiler, with the required service clearance;\u003c\/li\u003e\n\u003cli\u003econnecting the coil in 1 in. NPT to the boiler supply and return, with a circulator or zone valve;\u003c\/li\u003e\n\u003cli\u003econnecting the cold and hot water in 3\/4 in. NPT;\u003c\/li\u003e\n\u003cli\u003einstalling the relief valve and its discharge line;\u003c\/li\u003e\n\u003cli\u003ewiring the tank sensor or thermostat and setting hot water priority;\u003c\/li\u003e\n\u003cli\u003ecommissioning, air purging and maintenance advice.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHow installation day goes\u003c\/h3\u003e\n\u003cp\u003eOn installation day, hot water and heating are interrupted for a few hours, long enough to drain the old tank, modify the piping and fill the new loop. We then purge the air from the coil, check every fitting for leaks and run a complete heating cycle before leaving. We show you where the drain valve and the relief valve are, and we recommend one maintenance visit per year for the boiler and tank together.\u003c\/p\u003e\n\u003ch3\u003eWhere we work\u003c\/h3\u003e\n\u003cp\u003eWe serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, Saint-Hubert, La Prairie, Candiac, Rosemère, Sainte-Thérèse and the whole \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. Our \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e solution lets you spread out the cost of the project.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the Bradford White SS-50-L.\u003c\/strong\u003e Send us a photo of the boiler, its nameplate and your current tank, and we will prepare the visit.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":67801418662180,"sku":"SS-50-L","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_BRADFORD_WHITE_POWERSTOR_SS_50_L_50_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082266"},{"product_id":"chauffe-eau-indirect-thermo-2000-turbomax50-3-50-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"THERMO 2000 TURBOMAX50-3 Indirect Water Heater (50 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eA 50 US gallon indirect water heater that hands your family’s hot water to your electric boiler\u003c\/h2\u003e\n\u003cp\u003eIf your home is heated by an \u003cstrong\u003eelectric boiler\u003c\/strong\u003e, the unit that already produces hot water for the floors or radiators can also heat the water for the showers. The \u003cstrong\u003eThermo 2000 TurboMax 50-3 indirect water heater\u003c\/strong\u003e makes that link: a \u003cstrong\u003e50 US gallon\u003c\/strong\u003e tank fitted with a \u003cstrong\u003ehigh-exchange-capacity copper coil system\u003c\/strong\u003e that, according to the manufacturer, heats water instantly. AirGreen installs it in homes in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is a family format: enough reserve for the morning and evening peaks, a reasonable footprint in the basement and an installation that ties into the existing boiler.\u003c\/p\u003e\n\n\u003ch3\u003eWhy an indirect tank in a home heated with hot water\u003c\/h3\u003e\n\u003cp\u003eA home heated by an electric boiler often also has a separate electric water heater, with its own circuit and its own elements to replace one day. The TurboMax 50-3 groups both functions around a single heating unit. The boiler, already sized for the house, supplies the energy; the indirect tank turns it into domestic hot water, without the heating water and the potable water ever mixing. The day the old water heater reaches the end of its life is often the best time to make this change.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 50 US gallons\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e copper coils, exchange surface of 19.6 sq. ft.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAt 110 °F:\u003c\/strong\u003e maximum exchange capacity of 380,000 BTU\/h (111 kW); 703 US GPH first hour; 653 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAt 140 °F:\u003c\/strong\u003e maximum exchange capacity of 270,000 BTU\/h (79 kW); 346 US GPH first hour; 326 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAt 160 °F:\u003c\/strong\u003e maximum exchange capacity of 180,000 BTU\/h (53 kW); 190 US GPH first hour; 181 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTest conditions:\u003c\/strong\u003e domestic cold water at 40 °F, boiler water at 180 °F\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum domestic hot water flow:\u003c\/strong\u003e 9 gpm\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum pressure:\u003c\/strong\u003e 150 psi\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e potable water 1 1\/2 in male sweat; boiler 1 1\/4 in NPT male\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e height 60 3\/4 in, diameter 22 in\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 212 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat the 50 US gallon reserve brings\u003c\/h3\u003e\n\u003cp\u003eIn the manufacturer’s table, first-hour output exceeds continuous output: 703 US GPH versus 653 US GPH for water at 110 °F. This gap comes from the energy already stored in the tank when the demand begins. In practice, this reserve covers the start of the peak: the first morning shower, the children’s bath, a laundry load started at the same time. After that, output depends on what the boiler supplies continuously.\u003c\/p\u003e\n\n\u003ch3\u003eReading the 110 °F, 140 °F and 160 °F temperatures\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 gives its values for three domestic hot water temperatures. The 110 °F column corresponds to the mixed water of a shower. The 140 °F column corresponds to hotter produced water, brought back to a safe temperature with a \u003cstrong\u003ethermostatic mixing valve\u003c\/strong\u003e. The 160 °F column concerns particular uses. The hotter the water required, the lower the hourly output: at 140 °F, the TurboMax 50-3 delivers 346 US GPH in the first hour, and 190 US GPH at 160 °F. We set the temperature according to your use, keeping comfort and safety in mind.\u003c\/p\u003e\n\n\u003ch3\u003eThe boiler’s capacity sets the real output\u003c\/h3\u003e\n\u003cp\u003eThe published flows assume that the boiler supplies the exchanger’s maximum exchange capacity, that is 380,000 BTU\/h (111 kW) at 110 °F. A residential electric boiler supplies much less. The tank then works the same way, but continuous output follows the boiler’s capacity. The manufacturer adds that these values must be reduced for high-temperature and continuous-flow applications. We therefore do the calculation from your boiler, and we usually program \u003cstrong\u003ehot water priority\u003c\/strong\u003e so that the boiler devotes itself to the tank for a few minutes before returning to heating.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation in the basement\u003c\/h3\u003e\n\u003cp\u003eAt 60 3\/4 in high and 22 in in diameter, the TurboMax 50-3 is installed beside the boiler in most basements. It weighs 212 lb empty; once filled, it must sit on a solid, level floor, near a drain. Potable water connects in 1 1\/2 in male sweat and the boiler in 1 1\/4 in NPT male. The tank drain valve, supplied as standard, is used during periodic maintenance. The 9 gpm maximum domestic hot water flow guides the choice of distribution piping.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s warranty\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 provides a \u003cstrong\u003e15-year residential warranty\u003c\/strong\u003e, a \u003cstrong\u003e10-year commercial warranty\u003c\/strong\u003e and a \u003cstrong\u003e2-year warranty on mechanical components\u003c\/strong\u003e. The terms applicable to your home are confirmed in writing with the quote.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation of the Thermo 2000 TurboMax 50-3 by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. For this indirect water heater, our service includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eassessment of the electric boiler, its capacity and the planned location;\u003c\/li\u003e\n\u003cli\u003edraining, disconnecting and removing the old electric water heater;\u003c\/li\u003e\n\u003cli\u003econnecting the potable water in 1 1\/2 in, with thermostatic mixing valve and shut-off valves;\u003c\/li\u003e\n\u003cli\u003econnecting to the boiler in 1 1\/4 in, with circulator or zone valve, check valve and air vent;\u003c\/li\u003e\n\u003cli\u003ethe relief valve and its discharge pipe to the drain;\u003c\/li\u003e\n\u003cli\u003ewiring the control and setting hot water priority;\u003c\/li\u003e\n\u003cli\u003ecommissioning, balancing and maintenance advice.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, Ahuntsic, Pierrefonds, Greenfield Park, Saint-Constant, Lorraine and the entire \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. The on-site estimate is free, the quote is written and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free quote for the Thermo 2000 TurboMax 50-3.\u003c\/strong\u003e Send us your boiler’s rating plate and a photo of your current water heater: we will explain what the TurboMax will deliver in your home.\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801418694948,"sku":"TURBOMAX50-3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_THERMO_2000_TURBOMAX50_3_50_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082278"},{"product_id":"chauffe-eau-indirect-thermo-2000-turbomax50-5-50-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"THERMO 2000 TURBOMAX50-5 Indirect Water Heater (50 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eA 50 US gallon indirect water heater with a large copper exchanger for simultaneous use\u003c\/h2\u003e\n\u003cp\u003eSome homes are short not so much on volume as on flow. Two bathrooms used at the same time, a multi-jet shower, a tub filling while the washing machine runs: it is instantaneous flow that makes the difference. The \u003cstrong\u003eThermo 2000 TurboMax 50-5 indirect water heater\u003c\/strong\u003e pairs a \u003cstrong\u003e50 US gallon\u003c\/strong\u003e tank with a \u003cstrong\u003e32.7 sq. ft. copper coil system\u003c\/strong\u003e and a maximum domestic hot water flow of \u003cstrong\u003e15 gpm\u003c\/strong\u003e. It is fed by an \u003cstrong\u003eelectric boiler\u003c\/strong\u003e. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eA compact tank, a generous exchanger\u003c\/h3\u003e\n\u003cp\u003eThe TurboMax 50-5 keeps the footprint of a 50 US gallon tank, at 60 3\/4 in high and 22 in in diameter, but it houses an exchange surface of 32.7 sq. ft. Thermo 2000 describes this high-exchange-capacity copper coil system as a way to heat water instantly: domestic water is heated as it passes through the exchanger. The larger the surface, the more heat the exchanger can transfer at once, provided the boiler supplies it.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 50 US gallons\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e copper coils, exchange surface of 32.7 sq. ft.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWater at 110 °F:\u003c\/strong\u003e maximum exchange capacity of 645,000 BTU\/h (189 kW); 1,159 US GPH first hour; 1,109 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWater at 140 °F:\u003c\/strong\u003e maximum exchange capacity of 455,000 BTU\/h (133 kW); 569 US GPH first hour; 549 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWater at 160 °F:\u003c\/strong\u003e maximum exchange capacity of 300,000 BTU\/h (88 kW); 313 US GPH first hour; 302 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConditions:\u003c\/strong\u003e domestic cold water inlet at 40 °F, boiler supply at 180 °F\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum domestic hot water flow:\u003c\/strong\u003e 15 gpm\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum pressure:\u003c\/strong\u003e 150 psi\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e potable water 1 1\/2 in male sweat; boiler 1 1\/4 in NPT male\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e height 60 3\/4 in, diameter 22 in\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 230 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eA 15 gpm flow when several taps open\u003c\/h3\u003e\n\u003cp\u003eThe maximum domestic hot water flow shows how much hot water can leave the tank at a given moment. With 15 gpm, the TurboMax 50-5 is designed to supply several fixtures at the same time, which makes it a good candidate for a home with several bathrooms or a multi-jet shower. Thermo 2000 specifies that these values must be reduced for high-temperature and continuous-flow applications; we take this into account when sizing the piping and setting the thermostatic mixing valve.\u003c\/p\u003e\n\n\u003ch3\u003eWhere the TurboMax 50-5 is the right choice\u003c\/h3\u003e\n\u003cp\u003eThis model suits a large home heated by an electric boiler, where several people get ready at the same time in the morning. It also suits small businesses heated the same way: a hair salon rinsing continuously, a physiotherapy clinic with a few showers, a yoga studio. In these cases, it is not the reserve that is lacking, but the ability to deliver a lot of hot water at the same time.\u003c\/p\u003e\n\u003cp\u003eFor a home where hot water is mostly used one appliance at a time, a smaller exchanger is generally enough. We compare the options with you based on your real habits.\u003c\/p\u003e\n\n\u003ch3\u003eAn electric boiler that matches the exchanger\u003c\/h3\u003e\n\u003cp\u003eThe published exchange capacities, up to 645,000 BTU\/h (189 kW) for water at 110 °F, describe what the exchanger can transfer at most. A residential electric boiler supplies much less, and it is the boiler that sets the real continuous output. In a home, the TurboMax 50-5 exchanger therefore rarely works at full capacity; its advantage shows mainly in its 15 gpm maximum flow. In a business equipped with a larger electric boiler, the exchanger can make more of it. In both cases, we check the electrical service and the available capacity before proposing a configuration.\u003c\/p\u003e\n\n\u003ch3\u003eConnections and location\u003c\/h3\u003e\n\u003cp\u003ePotable water connects in 1 1\/2 in male sweat and the boiler in 1 1\/4 in NPT male. The tank weighs 230 lb empty and, once filled, must sit on a solid, level floor, near a drain. Its 22 in diameter lets it take its place beside the boiler in most mechanical rooms. The tank drain valve, supplied as standard, simplifies maintenance. The control is connected to the boiler with \u003cstrong\u003ehot water priority\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eSimple yearly maintenance\u003c\/h3\u003e\n\u003cp\u003eOne visit per year keeps the system reliable: a test of the relief valve, a check of the circulator and the control, an inspection of the fittings and a partial draining through the tank drain valve when the water carries sediment. In a business where hot water is used all day, we schedule this visit outside opening hours, so service to your customers is never interrupted.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s warranty\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 offers a \u003cstrong\u003e15-year residential warranty\u003c\/strong\u003e, a \u003cstrong\u003e10-year commercial warranty\u003c\/strong\u003e and a \u003cstrong\u003e2-year warranty on mechanical components\u003c\/strong\u003e. The warranty that applies to your installation is confirmed in writing with the quote.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation of the Thermo 2000 TurboMax 50-5 by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work. Our work includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eanalysis of your simultaneous uses and of the electric boiler’s capacity;\u003c\/li\u003e\n\u003cli\u003eassessment of the location, the floor and access to the drain;\u003c\/li\u003e\n\u003cli\u003eremoval of the old water heater;\u003c\/li\u003e\n\u003cli\u003econnecting the potable water in 1 1\/2 in, with thermostatic mixing valve and shut-off valves;\u003c\/li\u003e\n\u003cli\u003econnecting to the boiler in 1 1\/4 in, with a properly sized circulator, check valve and air vent;\u003c\/li\u003e\n\u003cli\u003ethe relief valve, its discharge pipe and, if needed, an expansion tank;\u003c\/li\u003e\n\u003cli\u003ewiring the control, commissioning and maintenance advice.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe serve homes and businesses in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, Outremont, Mount Royal, Boucherville, Blainville, L’Assomption and across the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. Free on-site estimate, written quote and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free quote for the Thermo 2000 TurboMax 50-5.\u003c\/strong\u003e Describe the appliances that run at the same time in your home: we will tell you whether this model is the right one.\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801421775140,"sku":"TURBOMAX50-5","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_THERMO_2000_TURBOMAX50_5_50_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082278"},{"product_id":"chauffe-eau-indirect-thermo-2000-doublemax-50-4-50-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"THERMO 2000 DOUBLEMAX 50-4 Indirect Water Heater (50 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eA 50 US gallon double-wall indirect water heater for homes heated by an electric boiler\u003c\/h2\u003e\n\u003cp\u003eYou heat your home with an \u003cstrong\u003eelectric boiler\u003c\/strong\u003e and radiant floors or radiators, and your old electric water heater takes up a corner of the basement. The \u003cstrong\u003eThermo 2000 DoubleMax 50-4 indirect water heater\u003c\/strong\u003e brings the two functions together: the boiler heats the house and produces hot water through a \u003cstrong\u003edouble-wall copper heat exchanger\u003c\/strong\u003e housed in a \u003cstrong\u003e50 US gallon\u003c\/strong\u003e tank. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIt is the format that best suits a typical single-family home: enough reserve for a family, a 22 in diameter that slips in beside the boiler and an output that depends directly on the boiler’s capacity.\u003c\/p\u003e\n\n\u003ch3\u003eHow an indirect water heater works\u003c\/h3\u003e\n\u003cp\u003eThe DoubleMax heats water from the boiler: hot water from the boiler circulates through copper piping wound in \u003cstrong\u003eparallel helicoidal lines\u003c\/strong\u003e inside the tank, then returns to the boiler. It transfers its heat to the potable water without ever mixing with it. When the water in the tank cools, the control calls for heat from the boiler, which feeds the exchanger until the set point is reached. AirGreen installs this tank with an \u003cstrong\u003eelectric boiler\u003c\/strong\u003e, on a zone dedicated to domestic hot water.\u003c\/p\u003e\n\n\u003ch3\u003eWhy a double-wall heat exchanger\u003c\/h3\u003e\n\u003cp\u003eIn an ordinary coil, a single thickness of metal separates the heating water from the water you drink. The DoubleMax uses two: the exchanger’s copper piping is \u003cstrong\u003edouble-wall\u003c\/strong\u003e. This extra barrier is sought after when the heating water contains an additive, such as antifreeze, or when an engineer or inspector requires double separation. Thermo 2000 also states that the copper components meet the low lead requirements for potable plumbing products and the \u003cstrong\u003eNSF 61\u003c\/strong\u003e standard.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 50 US gallons\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e double-wall copper, exchange surface of 24.7 sq. ft.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum domestic hot water flow:\u003c\/strong\u003e 12 gpm (value to be reduced for high-temperature and continuous-flow applications)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum pressure:\u003c\/strong\u003e 150 psi\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBoiler connection:\u003c\/strong\u003e 1 1\/4 in NPT male\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDrain valve:\u003c\/strong\u003e ¾ in brass ball valve, maximum working pressure of 150 psi\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e height 59 1\/4 in, diameter 22 in\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 260 lb (330 lb shipping)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eReading the output table by boiler capacity\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 publishes the output of the DoubleMax 50-4 according to boiler capacity, for cold water at 40 °F and boiler water at 180 °F. Each value reads in two parts, as first hour \/ continuous, in US gallons per hour. The first two lines of the table are those closest to a residential electric boiler:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e50,000 BTU\/h (15 kW) boiler:\u003c\/strong\u003e 136 \/ 86 US gallons for water at 110 °F; 80 \/ 60 at 140 °F; 69 \/ 60 at 160 °F.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e100,000 BTU\/h (29 kW) boiler:\u003c\/strong\u003e 222 \/ 172 US gallons at 110 °F; 140 \/ 120 at 140 °F; 129 \/ 120 at 160 °F.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 110 °F column corresponds to the mixed water coming out of a shower; the 140 °F column to hotter stored water, then brought back to a safe temperature by a mixing valve. The effect of the boiler is clear right away: doubling its capacity clearly increases continuous output, while the tank volume stays the same.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing the electric boiler capacity\u003c\/h3\u003e\n\u003cp\u003eAn electric boiler is sized first for heating the house. If it must also produce hot water, we check that its capacity gives enough output at peak times and we usually program \u003cstrong\u003ehot water priority\u003c\/strong\u003e: for a few minutes, the boiler devotes itself to the tank, then returns to the rooms. Thanks to the thermal mass of the radiant floor or radiators, this short detour is rarely felt in the house. The electrical service, the panel capacity and the circuit gauge are part of this check.\u003c\/p\u003e\n\n\u003ch3\u003eWho the DoubleMax 50-4 is for\u003c\/h3\u003e\n\u003cp\u003eThis model suits a family of three or four with one or two bathrooms, in a home already equipped with an electric boiler. It also suits new construction where radiant floors are planned from the start, or the replacement of an old indirect tank. For a home with a large tub or several simultaneous showers, a larger DoubleMax offers more reserve; we compare the formats during the assessment.\u003c\/p\u003e\n\n\u003ch3\u003eLocation and connections\u003c\/h3\u003e\n\u003cp\u003eAt 59 1\/4 in high and 22 in in diameter, the tank fits beside the boiler in most basements. The boiler connection is 1 1\/4 in NPT male; the size of the potable water connections is confirmed with the manufacturer’s sheet at the quote stage. The brass ball drain valve makes yearly maintenance easier. The 260 lb weight, plus that of the water, requires a solid, level floor, ideally near a drain.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s warranty\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 distinguishes residential and commercial use. In \u003cstrong\u003eresidential use\u003c\/strong\u003e, the tank and copper coils are covered by a \u003cstrong\u003e15-year warranty\u003c\/strong\u003e. In \u003cstrong\u003ecommercial use\u003c\/strong\u003e, the warranty on the tank and coils is \u003cstrong\u003e10 years\u003c\/strong\u003e. Mechanical parts are warranted for \u003cstrong\u003e2 years\u003c\/strong\u003e. The terms applicable to your installation are confirmed in writing with the quote.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation of the Thermo 2000 DoubleMax 50-4 by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work. For this indirect water heater, our work includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eassessment of the electric boiler, its capacity and the tank location;\u003c\/li\u003e\n\u003cli\u003edraining and removing the old water heater;\u003c\/li\u003e\n\u003cli\u003econnecting the cold and hot water, with thermostatic mixing valve and shut-off valves;\u003c\/li\u003e\n\u003cli\u003econnecting the exchanger to the boiler, with circulator or zone valve, check valve and air vent;\u003c\/li\u003e\n\u003cli\u003ethe relief valve and its discharge pipe to the drain;\u003c\/li\u003e\n\u003cli\u003ewiring the hot water control and setting priority at the boiler;\u003c\/li\u003e\n\u003cli\u003ecommissioning, purging the loop and maintenance advice.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, Brossard, La Prairie, Candiac, Sainte-Thérèse, Repentigny and the entire \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. Free on-site estimate, written quote and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free quote for the Thermo 2000 DoubleMax 50-4.\u003c\/strong\u003e Tell us the capacity of your electric boiler: we will tell you what hot water output you can really expect.\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801421807908,"sku":"DOUBLEMAX 50-4","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_THERMO_2000_DOUBLEMAX_50_4_50_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082266"},{"product_id":"chauffe-eau-indirect-bradford-white-ss-75-l-73-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"BRADFORD WHITE SS-75-L Indirect Water Heater (73 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003ePlenty of hot water for large homes heated by an electric boiler\u003c\/h2\u003e\n\u003cp\u003eA large freestanding tub, a multi-jet shower in the primary suite, a basement bathroom for guests: when a home adds up the fixtures, the hot water reserve becomes the weak link. The \u003cstrong\u003eBradford White SS-75-L indirect water heater\u003c\/strong\u003e meets this need with \u003cstrong\u003e73 US gallons (60 imperial gallons, 274 L)\u003c\/strong\u003e of potable water heated by the home's \u003cstrong\u003eelectric boiler\u003c\/strong\u003e, through a stainless steel coil. AirGreen installs and connects it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eThe big tub and back-to-back showers\u003c\/h3\u003e\n\u003cp\u003eFilling a large tub empties a good part of an ordinary tank in a few minutes. With an indirect tank, the boiler recharges the reserve while the water runs, which explains the first-hour rating of \u003cstrong\u003e367 gal\/h (1,389 L\/h)\u003c\/strong\u003e published for the SS-75-L according to AHRI. For a large family or a home that often has guests, it is the difference between a lukewarm shower at the end of the evening and hot water that lasts until the last person. These figures assume a boiler able to supply the output specified by the manufacturer, a point we explain below.\u003c\/p\u003e\n\u003ch3\u003eA tall, slim format\u003c\/h3\u003e\n\u003cp\u003eDespite its large capacity, the SS-75-L keeps a diameter of 24 in. (610 mm). It gains its volume in height, at 65 5\/8 in. (1,667 mm), which lets it take up little floor space in a mechanical room already crowded with the boiler, the electrical panel and the air exchanger. Empty, it weighs 142 lb (64 kg); once full, the weight increases considerably, so we check that the floor is sound at the intended location.\u003c\/p\u003e\n\u003ch3\u003eManufacturer specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 73 US gallons, 60 imperial gallons, 274 L.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFirst-hour rating (AHRI):\u003c\/strong\u003e 367 gal\/h or 1,389 L\/h, boiler at 180 °F (82 °C).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eContinuous draw:\u003c\/strong\u003e 307 gal\/h at 135 °F (1,162 L\/h at 57 °C).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eStandby heat loss:\u003c\/strong\u003e 0.4 °F\/h (0.22 °C\/h).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMinimum heat source input:\u003c\/strong\u003e 193,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMinimum heat source flow:\u003c\/strong\u003e 14.0 gal\/min (53.0 L\/min).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBoiler supply:\u003c\/strong\u003e 240 °F (116 °C) maximum.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e single-wall stainless steel coil, 1 in. (25 mm) outside diameter.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e 3\/4 in. NPT for potable water; 1 in. (25 mm) female NPT at the front for the boiler.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 65 5\/8 in. tall by 24 in. in diameter; 142 lb.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHow the coil does the work\u003c\/h3\u003e\n\u003cp\u003eThe SS-75-L contains no electric element. At the centre of the tank, a long stainless steel coil receives hot water from the boiler, which gives up its heat to the potable water and then returns to the boiler through the return connection. The two circuits remain separate at all times. When the tank sensor is satisfied, the boiler goes back to space heating. A priority control usually gives precedence to hot water during these cycles, which remain short.\u003c\/p\u003e\n\u003ch3\u003eThe boiler has to keep pace\u003c\/h3\u003e\n\u003cp\u003eAccording to Bradford White, the SS-75-L ratings are obtained with a heat source of at least 193,000 BTU\/h, a flow of 14.0 gal\/min and boiler water at 180 °F (82 °C). The manufacturer specifies that other conditions produce other results. In an electrically heated home, the boiler often has a more modest output: the tank then delivers its full 73 US gallon reserve, but it recharges more slowly than the table indicates. During the assessment, we compare your boiler's output, its heating load in extreme cold and your actual usage. If the boiler is already at its limit in January, we tell you before proposing anything.\u003c\/p\u003e\n\u003ch3\u003e444 stainless steel and low standby loss\u003c\/h3\u003e\n\u003cp\u003eThe tank and coil are made of \u003cstrong\u003e444 ferritic stainless steel\u003c\/strong\u003e, a chromium, molybdenum and titanium alloy, with no internal lining. With a standby loss of 0.4 °F\/h, the reserve holds its heat during quiet hours, which spares the boiler frequent restarts. The \u003cstrong\u003elow-restriction brass drain valve\u003c\/strong\u003e, with a tamper-resistant design, makes maintenance easier, and the model's ratings are AHRI certified.\u003c\/p\u003e\n\u003ch3\u003eSafe hot water at the tap\u003c\/h3\u003e\n\u003cp\u003eLarge tanks are sometimes set to a high temperature to stretch the reserve. In that case, we recommend a thermostatic mixing valve at the outlet, which brings the water back to a safe temperature at the taps while still taking advantage of the hotter reserve. It is a particularly useful precaution in a home with young children or older adults.\u003c\/p\u003e\n\u003ch3\u003eManufacturer's warranty\u003c\/h3\u003e\n\u003cp\u003eBradford White applies separate warranty terms for residential and commercial use. Your written quote specifies the coverage that matches your installation.\u003c\/p\u003e\n\u003ch2\u003eThe SS-75-L installed and connected by AirGreen\u003c\/h2\u003e\n\u003cp\u003eA family-owned heating and cooling company established in Montreal, AirGreen has been active for more than fifteen years and holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. We begin with a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, then give you a detailed \u003cstrong\u003ewritten quote\u003c\/strong\u003e. Installation includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eassessing the electric boiler, its output and its heating load;\u003c\/li\u003e\n\u003cli\u003echecking the location, the available height and the floor;\u003c\/li\u003e\n\u003cli\u003edraining and removing the old water heater;\u003c\/li\u003e\n\u003cli\u003econnecting the coil to the boiler in 1 in. NPT, with a circulator or zone valve;\u003c\/li\u003e\n\u003cli\u003econnecting the cold and hot water in 3\/4 in. NPT, with a thermostatic mixing valve if needed;\u003c\/li\u003e\n\u003cli\u003einstalling the relief valve and its discharge line;\u003c\/li\u003e\n\u003cli\u003ewiring the control and setting hot water priority;\u003c\/li\u003e\n\u003cli\u003ecommissioning, air purging and our maintenance advice, including one partial flush per year.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eService area and quote\u003c\/h3\u003e\n\u003cp\u003eWe install the SS-75-L in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, as well as in Boucherville, Chambly, Saint-Bruno-de-Montarville, Terrebonne, Blainville and throughout the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. For a project of this scope, our \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e option lets you spread out the payments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBook your free estimate for the Bradford White SS-75-L.\u003c\/strong\u003e A photo of your boiler's nameplate and of the mechanical room lets us arrive prepared.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":67801422299428,"sku":"SS-75-L","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_BRADFORD_WHITE_POWERSTOR_SS_75_L_73_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082267"},{"product_id":"chauffe-eau-indirect-thermo-2000-turbomax80-5-80-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"THERMO 2000 TURBOMAX80-5 Indirect Water Heater (80 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eAn 80 US gallon indirect water heater for plexes and large homes heated by an electric boiler\u003c\/h2\u003e\n\u003cp\u003eIn a duplex, a triplex or a large home heated by an \u003cstrong\u003eelectric boiler\u003c\/strong\u003e, hot water is shared between several households or several floors, and the peaks overlap. The \u003cstrong\u003eThermo 2000 TurboMax 80-5 indirect water heater\u003c\/strong\u003e answers this situation with an \u003cstrong\u003e80 US gallon\u003c\/strong\u003e tank, a \u003cstrong\u003e32.7 sq. ft. copper coil system\u003c\/strong\u003e and a maximum domestic hot water flow of \u003cstrong\u003e15 gpm\u003c\/strong\u003e. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhen the reserve matters more than the capacity\u003c\/h3\u003e\n\u003cp\u003eAn electric boiler is sized to heat the building, and its capacity is limited by the electrical service. That is why tank volume matters so much in a plex: it stores energy during off-peak hours and releases it when everyone opens the tap. The manufacturer’s table shows this clearly. For water at 110 °F, first-hour output reaches 1,189 US GPH, versus 1,109 US GPH continuous; the gap comes from the energy already stored in the tank. With a modest boiler, this reserve becomes the first line of defence against a lukewarm shower.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 80 US gallons\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e high-exchange-capacity copper coils, surface of 32.7 sq. ft.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDomestic hot water at 110 °F:\u003c\/strong\u003e maximum exchange capacity of 645,000 BTU\/h (189 kW); 1,189 US GPH first hour; 1,109 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDomestic hot water at 140 °F:\u003c\/strong\u003e maximum exchange capacity of 455,000 BTU\/h (133 kW); 581 US GPH first hour; 549 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDomestic hot water at 160 °F:\u003c\/strong\u003e maximum exchange capacity of 300,000 BTU\/h (88 kW); 316 US GPH first hour; 302 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConditions:\u003c\/strong\u003e domestic cold water at 40 °F, boiler water at 180 °F\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum domestic hot water flow:\u003c\/strong\u003e 15 gpm\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum pressure:\u003c\/strong\u003e 150 psi\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e potable water 1 1\/2 in male sweat; boiler 1 1\/2 in NPT male\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e height 74 3\/4 in, diameter 24 in\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 308 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePlexes and multigenerational homes\u003c\/h3\u003e\n\u003cp\u003eIn a duplex or triplex whose electric boiler serves all the units, a single indirect tank can replace several electric water heaters spread across the basements. The owner then has only one hot water unit to maintain, and the freed space can be used for something else. In a multigenerational home, the principle is the same: one tank, one heat source, and a reserve large enough that the two households do not have to organize themselves around hot water. We check with you the requirements that apply to distribution between units before proposing this configuration.\u003c\/p\u003e\n\n\u003ch3\u003eReading the maximum exchange capacity\u003c\/h3\u003e\n\u003cp\u003eThe first-hour and continuous output values assume that the boiler supplies the exchanger’s maximum exchange capacity: 645,000 BTU\/h (189 kW) for water at 110 °F. A plex electric boiler generally supplies much less. With it, the TurboMax 80-5 works the same way, but continuous output follows the boiler’s real capacity. Thermo 2000 also specifies that the values must be reduced for high-temperature and continuous-flow applications. Our quote states the output you can expect with your boiler, not the best line of the table.\u003c\/p\u003e\n\n\u003ch3\u003eA tank 74 3\/4 in tall\u003c\/h3\u003e\n\u003cp\u003eThe TurboMax 80-5 is 74 3\/4 in high and 24 in in diameter. In plex basements, where the height under the beams is often limited by piping and ducts, this measurement must be checked before ordering, adding the space needed for the top fittings. The tank weighs 308 lb empty: we plan the route down the stairs and a solid, level floor near a drain.\u003c\/p\u003e\n\n\u003ch3\u003eConnections and distribution\u003c\/h3\u003e\n\u003cp\u003ePotable water and the boiler both connect in 1 1\/2 in, male sweat on the potable water side and NPT male on the boiler side. When hot water must travel several floors, we add a recirculation loop when needed so it reaches distant taps quickly, and a \u003cstrong\u003ethermostatic mixing valve\u003c\/strong\u003e to deliver a safe temperature. The control is connected to the electric boiler with \u003cstrong\u003ehot water priority\u003c\/strong\u003e. The tank drain valve, supplied as standard, is used for yearly maintenance.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing the production temperature\u003c\/h3\u003e\n\u003cp\u003eThe temperature at which water is produced changes the quantity available. At 140 °F, the TurboMax 80-5 gives 581 US GPH in the first hour and 549 US GPH continuous; at 160 °F, 316 US GPH and 302 US GPH. In a plex, we choose the production temperature according to real uses, knowing that every increase reduces hourly output, then the thermostatic mixing valve ensures a safe temperature before the water reaches the units. This setting is discussed with you according to the occupants’ ages and the length of the piping.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s warranty\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 offers a \u003cstrong\u003e15-year residential warranty\u003c\/strong\u003e, a \u003cstrong\u003e10-year commercial warranty\u003c\/strong\u003e and a \u003cstrong\u003e2-year warranty on mechanical components\u003c\/strong\u003e. The category applicable to your building is confirmed in writing with the quote.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation of the Thermo 2000 TurboMax 80-5 by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal, active in heating, ventilation and air conditioning for more than fifteen years and holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. For this indirect water heater, our work includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eanalysis of each unit’s needs and of the electric boiler’s capacity;\u003c\/li\u003e\n\u003cli\u003echeck of the free height, the delivery route and the floor;\u003c\/li\u003e\n\u003cli\u003eremoval of the old electric water heaters;\u003c\/li\u003e\n\u003cli\u003econnecting the potable water in 1 1\/2 in, with thermostatic mixing valve and, if needed, a recirculation loop;\u003c\/li\u003e\n\u003cli\u003econnecting to the boiler in 1 1\/2 in, with circulator, check valve and air vent;\u003c\/li\u003e\n\u003cli\u003ethe relief valve, its discharge pipe and the expansion tank;\u003c\/li\u003e\n\u003cli\u003ewiring the control, commissioning and a maintenance plan.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, Rosemont, Villeray, Saint-Hubert, Lachine, Sainte-Rose and the entire \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. The on-site estimate is free, the quote is written and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free quote for the Thermo 2000 TurboMax 80-5.\u003c\/strong\u003e Tell us how many units share the boiler and send a photo of its rating plate: we will propose a clear configuration.\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801426526500,"sku":"TURBOMAX80-5","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_THERMO_2000_TURBOMAX80_5_80_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082278"},{"product_id":"chauffe-eau-indirect-bradford-white-ss-120-l-111-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"BRADFORD WHITE SS-120-L Indirect Water Heater (111 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eA large stainless steel indirect reserve for electrically heated buildings and businesses\u003c\/h2\u003e\n\u003cp\u003eWhen several apartments, a daycare, a hair salon or a locker room with showers depend on the same hot water source, a residential tank is no longer enough. The \u003cstrong\u003eBradford White SS-120-L indirect water heater\u003c\/strong\u003e stores \u003cstrong\u003e111 US gallons (92 imperial gallons, 420 L)\u003c\/strong\u003e of potable water, heated by a stainless steel coil connected to an \u003cstrong\u003eelectric boiler\u003c\/strong\u003e. It is the largest tank in the SS series that we offer, and the only one in the series with 1 in. potable water connections. AirGreen installs it in buildings in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhich buildings this tank is designed for\u003c\/h3\u003e\n\u003cp\u003eThe SS-120-L is aimed first at small multi-unit buildings whose central heating runs on an electric boiler, at businesses that use a lot of hot water in a short time, and at very large homes. In a converted plex where each apartment had its own tank, a central indirect tank can also simplify maintenance, provided the boiler and the distribution allow it. Every case calls for an analysis: number of plumbing fixtures, simultaneous use, peak hours and boiler capacity. We do this calculation before proposing the model.\u003c\/p\u003e\n\u003ch3\u003eManufacturer specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 111 US gallons, 92 imperial gallons, 420 L.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFirst-hour rating (AHRI):\u003c\/strong\u003e 409 gal\/h (1,548 L\/h), with boiler water at 180 °F (82 °C).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eContinuous draw:\u003c\/strong\u003e 319 gal\/h at 135 °F (1,208 L\/h at 57 °C).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eStandby heat loss:\u003c\/strong\u003e 0.3 °F\/h (0.16 °C\/h).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMinimum heat source input:\u003c\/strong\u003e 199,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMinimum heat source flow:\u003c\/strong\u003e 9.0 gal\/min (34.0 L\/min).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum boiler supply temperature:\u003c\/strong\u003e 240 °F (116 °C).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e single-wall stainless steel coil, 1 in. (25 mm) outside diameter.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e potable water in 1 in. NPT; boiler in 1 in. (25 mm) female NPT at the front, supply and return.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e height of 63 3\/8 in. (1,610 mm), diameter of 30 1\/4 in. (768 mm).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 217 lb (98 kg) empty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe indirect principle applied to a large volume\u003c\/h3\u003e\n\u003cp\u003eThe tank has no heating element. Boiler water flows through the coil, gives up its heat to the potable water and returns to the boiler, without ever coming into contact with the domestic water. On a 420 L volume, this heating method has a clear advantage: the boiler recharges the reserve while the water is being used, which gives a first-hour rating of 409 gal\/h and a continuous draw of 319 gal\/h at 135 °F. For a building where morning showers are concentrated in a short period, this recharging capacity matters as much as the stored volume.\u003c\/p\u003e\n\u003ch3\u003ePairing the SS-120-L with a high-output electric boiler\u003c\/h3\u003e\n\u003cp\u003eBradford White states that these ratings are obtained with a heat source of at least 199,000 BTU\/h, a flow of at least 9.0 gal\/min and boiler water at 180 °F (82 °C). The manufacturer also specifies that different conditions give different results. A smaller electric boiler will heat the reserve properly, but more slowly; in a building, this can mean less hot water at the end of the peak. We therefore size the whole system: boiler output, the share reserved for heating in extreme cold, circulator flow and priority control. If the existing boiler cannot keep up, we present the options before starting the work.\u003c\/p\u003e\n\u003ch3\u003e1 in. potable water connections\u003c\/h3\u003e\n\u003cp\u003eUnlike the smaller models in the series, which use 3\/4 in. connections, the SS-120-L takes in cold water and delivers hot water through 1 in. NPT fittings. This larger diameter limits pressure loss when several apartments or several fixtures draw at the same time. The boiler connections, also 1 in. NPT, are at the front of the tank to make piping easier in a mechanical room.\u003c\/p\u003e\n\u003ch3\u003e444 stainless steel and low standby loss\u003c\/h3\u003e\n\u003cp\u003eThe tank and heat exchanger are made of \u003cstrong\u003e444 ferritic stainless steel\u003c\/strong\u003e, a chromium, molybdenum and titanium alloy. There is no internal lining to monitor. With a standby loss of 0.3 °F\/h, the lowest of the SS tanks we offer, the large reserve holds its temperature well overnight and during quiet hours. The model's ratings are AHRI certified.\u003c\/p\u003e\n\u003ch3\u003eHandling and location\u003c\/h3\u003e\n\u003cp\u003eWith a diameter of 30 1\/4 in. and an empty weight of 217 lb, the SS-120-L requires preparation. We measure the doors, hallways and stairs leading to the mechanical room, and we check that the slab or floor can support the tank once filled with 420 L of water. Service space around the front connections and the relief valve is planned from the first visit.\u003c\/p\u003e\n\u003ch3\u003eResidential or commercial warranty\u003c\/h3\u003e\n\u003cp\u003eBradford White applies different warranty terms depending on the use, residential or commercial. For a tank of this size, the category depends on your building: we state it clearly in the written quote.\u003c\/p\u003e\n\u003ch2\u003eInstallation of the SS-120-L by AirGreen in Greater Montreal buildings\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company established in Montreal and active for more than fifteen years. We hold RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Every project starts with a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e and continues with a \u003cstrong\u003ewritten quote\u003c\/strong\u003e. Installation includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eanalysing the building's hot water demand and the output of the electric boiler;\u003c\/li\u003e\n\u003cli\u003eassessing the location, access and floor capacity;\u003c\/li\u003e\n\u003cli\u003edraining and removing the old tanks, where applicable;\u003c\/li\u003e\n\u003cli\u003econnecting the coil to the boiler in 1 in. NPT, with a circulator and priority control;\u003c\/li\u003e\n\u003cli\u003econnecting the cold and hot water in 1 in. NPT, with a thermostatic mixing valve if the use calls for it;\u003c\/li\u003e\n\u003cli\u003einstalling the relief valve and its discharge line;\u003c\/li\u003e\n\u003cli\u003ecommissioning, purging air from the loop and setting the temperatures;\u003c\/li\u003e\n\u003cli\u003ea maintenance plan suited to heavy use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaintaining a heavily used tank\u003c\/h3\u003e\n\u003cp\u003eIn a building or a business, the tank works harder than in a house. We recommend at least one visit per year: a partial flush to remove sediment, a test of the relief valve, and a check of the fittings, the circulator and the boiler control. For building owners, this regular follow-up avoids learning about a breakdown from a tenant's call.\u003c\/p\u003e\n\u003ch3\u003eService area\u003c\/h3\u003e\n\u003cp\u003eWe work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, Brossard, Saint-Laurent, Anjou, LaSalle, Terrebonne and everywhere on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. Owners can spread out the investment through our \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the Bradford White SS-120-L.\u003c\/strong\u003e Send us the number of apartments or fixtures, and a photo of the boiler and its nameplate: we will prepare a visit and a written quote.\u003c\/p\u003e","brand":"Bradford White","offers":[{"title":"Default Title","offer_id":67801427050788,"sku":"SS-120-L","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_BRADFORD_WHITE_POWERSTOR_SS_120_L_111_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082267"},{"product_id":"chauffe-eau-indirect-thermo-2000-turbomax80-5a-80-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"THERMO 2000 TURBOMAX80-5A Indirect Water Heater (80 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eAn 80 US gallon indirect water heater with 2 in potable water connections for small businesses and new construction\u003c\/h2\u003e\n\u003cp\u003eIn a café, a daycare, a clinic or a small new building heated by an \u003cstrong\u003eelectric boiler\u003c\/strong\u003e, hot water must circulate through a longer and busier network than in a home. The \u003cstrong\u003eThermo 2000 TurboMax 80-5A indirect water heater\u003c\/strong\u003e combines an \u003cstrong\u003e80 US gallon\u003c\/strong\u003e tank, a \u003cstrong\u003e32.7 sq. ft. copper coil system\u003c\/strong\u003e and \u003cstrong\u003e2 in male sweat potable water connections\u003c\/strong\u003e, suited to larger-diameter distribution. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhat 2 in connections change\u003c\/h3\u003e\n\u003cp\u003eThe diameter of the potable water connections determines that of the piping leaving the tank. With 2 in connections, the TurboMax 80-5A connects directly to a commercial distribution of good diameter, without a reduction at the outlet. In a building where several sinks, a dishwasher and hand basins are supplied at the same time, properly sized piping limits pressure losses and temperature swings at the tap. The model’s maximum domestic hot water flow is 15 gpm; we design the network around that value and the fixtures to be served.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 80 US gallons\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e high-exchange-capacity copper coils, surface of 32.7 sq. ft.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAt 110 °F:\u003c\/strong\u003e maximum exchange capacity of 645,000 BTU\/h (189 kW); 1,189 US GPH first hour; 1,109 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAt 140 °F:\u003c\/strong\u003e maximum exchange capacity of 455,000 BTU\/h (133 kW); 581 US GPH first hour; 549 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAt 160 °F:\u003c\/strong\u003e maximum exchange capacity of 300,000 BTU\/h (88 kW); 316 US GPH first hour; 302 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConditions:\u003c\/strong\u003e domestic cold water at 40 °F, boiler water at 180 °F\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum domestic hot water flow:\u003c\/strong\u003e 15 gpm\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum pressure:\u003c\/strong\u003e 150 psi\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e potable water 2 in male sweat; boiler 1 1\/2 in NPT male\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e height 74 3\/4 in, diameter 24 in\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 317 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eRestaurants, cafés and daycares\u003c\/h3\u003e\n\u003cp\u003eThe consumption profile of a small business has nothing in common with that of a home. In a café, the pot sink and dishwasher run continuously at busy times. In a daycare, handwashing, dishes and cleaning are spread over the whole day, with peaks at lunch. In a clinic, the hand basins run from morning to night. The TurboMax 80-5A meets these profiles with an 80 US gallon reserve that absorbs the peaks and an exchanger that keeps production going as long as the electric boiler supplies the necessary heat.\u003c\/p\u003e\n\n\u003ch3\u003eHigher temperatures and user safety\u003c\/h3\u003e\n\u003cp\u003eSeveral commercial uses require hotter water than a shower. Thermo 2000’s table shows, for water at 140 °F, 581 US GPH in the first hour and 549 US GPH continuous; at 160 °F, 316 US GPH and 302 US GPH. The manufacturer specifies that these values must be reduced for high-temperature and continuous-flow applications. When water is produced at a high temperature, a \u003cstrong\u003ethermostatic mixing valve\u003c\/strong\u003e brings the water delivered to hand basins and washrooms back to a safe temperature, which matters especially in a daycare.\u003c\/p\u003e\n\n\u003ch3\u003eReal output with an electric boiler\u003c\/h3\u003e\n\u003cp\u003eThe published flows assume that the boiler supplies the exchanger’s maximum exchange capacity, up to 645,000 BTU\/h (189 kW) for water at 110 °F. With an electric boiler, the available capacity depends on the building’s electrical service, and it is that capacity that sets the real continuous output. We establish this capacity from the start, then tell you the expected output. If a gap remains with your needs, we discuss it before ordering rather than after commissioning.\u003c\/p\u003e\n\n\u003ch3\u003eNew construction: planning the mechanical room\u003c\/h3\u003e\n\u003cp\u003eIn a new project, the best time to plan hot water is at the drawing stage. The TurboMax 80-5A is 74 3\/4 in high and 24 in in diameter and weighs 317 lb empty. You need enough free height, taking the top fittings into account, a floor able to carry the filled tank, a nearby drain and clear access for service. The boiler connection is 1 1\/2 in NPT male. The tank drain valve, supplied as standard, makes yearly maintenance easier.\u003c\/p\u003e\n\n\u003ch3\u003ePlanned maintenance in a commercial setting\u003c\/h3\u003e\n\u003cp\u003eIn a business, a hot water outage is costly: a kitchen cannot open, a daycare has to make other arrangements. We recommend a yearly visit scheduled outside opening hours. It includes a test of the relief valve, a check of the circulator, the control and the mixing valve, an inspection of the fittings and a partial draining through the tank drain valve when the water carries sediment.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s warranty\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 provides a \u003cstrong\u003e10-year commercial warranty\u003c\/strong\u003e, a \u003cstrong\u003e15-year residential warranty\u003c\/strong\u003e and a \u003cstrong\u003e2-year warranty on mechanical components\u003c\/strong\u003e. The warranty applicable to your building is confirmed in writing with the quote.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation of the Thermo 2000 TurboMax 80-5A by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. For this indirect water heater, our service includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eanalysis of the consumption profile and of the electric boiler’s capacity;\u003c\/li\u003e\n\u003cli\u003ecoordination with the project drawings or assessment of the existing mechanical room;\u003c\/li\u003e\n\u003cli\u003eremoval of old units, where applicable;\u003c\/li\u003e\n\u003cli\u003econnecting the potable water in 2 in, with thermostatic mixing valve and isolation valves;\u003c\/li\u003e\n\u003cli\u003econnecting to the boiler in 1 1\/2 in, with circulator, check valve and air vent;\u003c\/li\u003e\n\u003cli\u003ethe relief valve, its discharge pipe and the expansion tank;\u003c\/li\u003e\n\u003cli\u003ewiring the control, commissioning and a yearly maintenance plan.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe work with business owners, developers and property managers in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, Brossard, Boucherville, Saint-Bruno, Mirabel, Terrebonne and the entire \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. Free on-site estimate, written quote and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free quote for the Thermo 2000 TurboMax 80-5A.\u003c\/strong\u003e Send us your drawings or a few photos of your mechanical room: we will propose a clear, compliant installation.\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801427083556,"sku":"TURBOMAX80-5A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_THERMO_2000_TURBOMAX80_5A_80_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082278"},{"product_id":"chauffe-eau-indirect-thermo-2000-turbomax120-9-119-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"THERMO 2000 TURBOMAX120-9 Indirect Water Heater (119 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eA 119 US gallon indirect water heater to centralize hot water in an apartment building\u003c\/h2\u003e\n\u003cp\u003eIn many buildings in the region, each apartment still has its own electric water heater, often hidden in a closet. When the building is heated by a central \u003cstrong\u003eelectric boiler\u003c\/strong\u003e, it becomes possible to produce all the hot water in one place. The \u003cstrong\u003eThermo 2000 TurboMax 120-9 indirect water heater\u003c\/strong\u003e is designed for this role: a \u003cstrong\u003e119 US gallon\u003c\/strong\u003e tank, a \u003cstrong\u003e58.9 sq. ft. copper coil system\u003c\/strong\u003e and a maximum domestic hot water flow of \u003cstrong\u003e27 gpm\u003c\/strong\u003e. AirGreen installs it in buildings in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eCentralize rather than multiply water heaters\u003c\/h3\u003e\n\u003cp\u003eA dozen individual water heaters means as many units to replace one day, as many leak risks inside the apartments and as many visits to tenants. Centralized production groups everything in the mechanical room: a single tank to maintain, accessible without disturbing anyone, and an electric boiler serving both heating and hot water. For the owner, management becomes simpler; for tenants, repairs no longer take place in their unit. Before proposing this change, we review with you the cost allocation and the requirements that apply to distribution between units.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 119 US gallons\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e high-exchange-capacity copper coils, surface of 58.9 sq. ft.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDomestic hot water at 110 °F:\u003c\/strong\u003e maximum exchange capacity of 1,165,000 BTU\/h (341 kW); 2,122 US GPH first hour; 2,002 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDomestic hot water at 140 °F:\u003c\/strong\u003e maximum exchange capacity of 820,000 BTU\/h (240 kW); 1,038 US GPH first hour; 990 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDomestic hot water at 160 °F:\u003c\/strong\u003e maximum exchange capacity of 545,000 BTU\/h (160 kW); 569 US GPH first hour; 549 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConditions:\u003c\/strong\u003e domestic cold water at 40 °F, boiler water at 180 °F\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum domestic hot water flow:\u003c\/strong\u003e 27 gpm\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum pressure:\u003c\/strong\u003e 150 psi\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e potable water 2 in male sweat; boiler 2 in NPT male\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e height 76 3\/4 in, diameter 28 in\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 430 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommercial-level exchange capacities\u003c\/h3\u003e\n\u003cp\u003eThe TurboMax copper coil system heats water instantly, according to Thermo 2000, and its exchanger can transfer up to 1,165,000 BTU\/h (341 kW) for water at 110 °F. These figures show the exchanger’s maximum capacity, not the guaranteed output of your installation. With an electric boiler, it is the boiler’s capacity, and therefore the building’s electrical service, that sets the real continuous output. With an electric boiler, the exchanger is rarely the limiting factor; the real question is how much electrical capacity the building can devote to hot water. We do this calculation with you based on the existing or planned boiler.\u003c\/p\u003e\n\n\u003ch3\u003eFlow and distribution in the building\u003c\/h3\u003e\n\u003cp\u003eThe 27 gpm maximum domestic hot water flow can supply many units at the same time. Thermo 2000 specifies that these values must be reduced for high-temperature and continuous-flow applications. In a building, hot water travels several floors: we usually plan a \u003cstrong\u003erecirculation loop\u003c\/strong\u003e so it reaches distant units quickly, and a \u003cstrong\u003ethermostatic mixing valve\u003c\/strong\u003e at the tank outlet to deliver a safe temperature. The 2 in connections, on both the potable water and boiler sides, fit commercial-diameter distribution piping.\u003c\/p\u003e\n\n\u003ch3\u003eProduction at 140 °F and 160 °F\u003c\/h3\u003e\n\u003cp\u003eThe choice of production temperature directly affects the quantity of water available. According to the manufacturer’s table, the exchanger can transfer up to 820,000 BTU\/h (240 kW) for water at 140 °F, with 1,038 US GPH in the first hour and 990 US GPH continuous, and up to 545,000 BTU\/h (160 kW) for water at 160 °F, with 569 US GPH and 549 US GPH. The hotter the water produced, the lower the hourly output. In a residential building, we therefore choose the temperature according to real uses, and a mixing valve ensures a safe temperature for the units; in a mixed-use building with a business on the ground floor, hotter production meets more demanding uses.\u003c\/p\u003e\n\n\u003ch3\u003eDelivering and placing a 430 lb tank\u003c\/h3\u003e\n\u003cp\u003eThe TurboMax 120-9 weighs 430 lb empty and is 76 3\/4 in high and 28 in in diameter. In an existing building, the mechanical room is often in the basement, at the end of a narrow staircase. We plan the route, door widths, free height under the pipes and the floor capacity once the tank is filled. A nearby drain and service space around the fittings and drain valve are planned from the design stage.\u003c\/p\u003e\n\n\u003ch3\u003eContinuity of service\u003c\/h3\u003e\n\u003cp\u003eWhen all of a building’s hot water depends on a single tank, maintenance must be planned. Well-placed isolation valves allow work on the boiler, circulator or mixing valve while limiting the length of the outage. We recommend a yearly visit, announced to tenants in advance, which includes a test of the relief valve, a check of the controls and a partial draining through the tank drain valve.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s warranty\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 offers a \u003cstrong\u003e10-year commercial warranty\u003c\/strong\u003e and a \u003cstrong\u003e15-year residential warranty\u003c\/strong\u003e, as well as a \u003cstrong\u003e2-year warranty on mechanical components\u003c\/strong\u003e. The category that applies to your building is confirmed in writing with the quote.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation of the Thermo 2000 TurboMax 120-9 by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work. For centralizing a building’s hot water, our work includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea survey of the units, appliances and electric boiler capacity;\u003c\/li\u003e\n\u003cli\u003eassessment of the mechanical room, floor, drain and delivery route;\u003c\/li\u003e\n\u003cli\u003eremoval and disposal of the old individual water heaters, where applicable;\u003c\/li\u003e\n\u003cli\u003econnecting the potable water in 2 in, with thermostatic mixing valve and recirculation loop;\u003c\/li\u003e\n\u003cli\u003econnecting to the boiler in 2 in, with circulator, isolation valves and air vents;\u003c\/li\u003e\n\u003cli\u003ethe relief valve, its discharge pipe and the expansion tank;\u003c\/li\u003e\n\u003cli\u003ewiring the controls, commissioning and a yearly maintenance plan.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe work with building owners and property managers in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, Côte-des-Neiges, Notre-Dame-de-Grâce, Saint-Léonard, Brossard, Chomedey and across the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. The on-site estimate is free, the quote is written and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free quote for the Thermo 2000 TurboMax 120-9.\u003c\/strong\u003e Tell us the number of units and the boiler in place: we will present a clear, step-by-step centralization project.\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801428853028,"sku":"TURBOMAX120-9","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_THERMO_2000_TURBOMAX120_9_119_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082279"},{"product_id":"chauffe-eau-indirect-thermo-2000-turbomax120-9a-125-120-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"THERMO 2000 TURBOMAX120-9A 125 Indirect Water Heater (120 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eA 120 US gallon indirect water heater with 2 1\/2 in connections for commercial kitchens, laundries and hotels\u003c\/h2\u003e\n\u003cp\u003eIn a restaurant kitchen, a commercial laundry or a hotel, hot water is used in large volumes and at high flow. When the building is heated by an \u003cstrong\u003eelectric boiler\u003c\/strong\u003e, the \u003cstrong\u003eThermo 2000 TurboMax 120-9A 125 indirect water heater\u003c\/strong\u003e can handle production: a \u003cstrong\u003e120 US gallon\u003c\/strong\u003e tank, a \u003cstrong\u003e58.9 sq. ft. copper coil system\u003c\/strong\u003e, a maximum domestic hot water flow of \u003cstrong\u003e27 gpm\u003c\/strong\u003e and \u003cstrong\u003e2 1\/2 in male sweat potable water connections\u003c\/strong\u003e. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003e2 1\/2 in connections for high flows\u003c\/h3\u003e\n\u003cp\u003eThe diameter of the potable water connections is the first visible difference of this model. At 2 1\/2 in, the tank connects to a large-diameter commercial distribution, without a reduction at the outlet, which limits pressure losses when several appliances draw hot water at the same time. The boiler connection is 2 in NPT male. According to Thermo 2000, the high-exchange-capacity copper coil system heats water instantly, as it passes through the exchanger.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 120 US gallons\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e copper coils, exchange surface of 58.9 sq. ft.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAt 110 °F:\u003c\/strong\u003e maximum exchange capacity of 1,165,000 BTU\/h (341 kW); 2,122 US GPH first hour; 2,002 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAt 140 °F:\u003c\/strong\u003e maximum exchange capacity of 820,000 BTU\/h (240 kW); 1,038 US GPH first hour; 990 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAt 160 °F:\u003c\/strong\u003e maximum exchange capacity of 545,000 BTU\/h (160 kW); 569 US GPH first hour; 549 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConditions:\u003c\/strong\u003e domestic cold water at 40 °F, boiler water at 180 °F\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum domestic hot water flow:\u003c\/strong\u003e 27 gpm\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum pressure:\u003c\/strong\u003e 125 psi\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e potable water 2 1\/2 in male sweat; boiler 2 in NPT male\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e height 76 3\/4 in, diameter 28 in\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 450 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHotels, laundries and kitchens: three peak profiles\u003c\/h3\u003e\n\u003cp\u003eA hotel has a very sharp peak in the morning, when guests shower before checking out, then another in the evening. A commercial laundry fills several washers at once, several times an hour. A restaurant kitchen draws hot water almost continuously during service, for the pot sink and cleaning. These three profiles have one thing in common: high flow over an extended period. That is where the 27 gpm maximum flow and the 2 1\/2 in connections make sense. Thermo 2000 specifies that the values must be reduced for high-temperature and continuous-flow applications, which is precisely the case for a laundry or a kitchen; we take this into account in the sizing.\u003c\/p\u003e\n\n\u003ch3\u003eA 125 psi maximum pressure to respect\u003c\/h3\u003e\n\u003cp\u003eThe maximum pressure of this model is 125 psi. In a commercial building, supply pressure can be high, especially when a booster pump feeds the upper floors. We measure the pressure at the water entrance and install a \u003cstrong\u003epressure-reducing valve\u003c\/strong\u003e upstream of the tank when needed. The relief valve is chosen according to this maximum pressure, and an expansion tank absorbs the expansion of the heated water. If the measured pressure does not allow this limit to be respected reliably, we tell you before ordering and review the configuration with you.\u003c\/p\u003e\n\n\u003ch3\u003eThe electric boiler sets the real output\u003c\/h3\u003e\n\u003cp\u003eThe published exchange capacities, up to 1,165,000 BTU\/h (341 kW) for water at 110 °F, describe what the exchanger can transfer at most. With an electric boiler, the real continuous output depends on the capacity that the building’s electrical service can devote to hot water. Commercial uses often require hotter water: at 140 °F, the table shows 1,038 US GPH in the first hour and 990 US GPH continuous; at 160 °F, 569 US GPH and 549 US GPH, always at full exchange capacity. We establish with you the available capacity and the expected output before any order.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation in the mechanical room\u003c\/h3\u003e\n\u003cp\u003eThe TurboMax 120-9A 125 weighs 450 lb empty and is 76 3\/4 in high and 28 in in diameter. We plan the delivery route, free height, floor capacity and proximity to a drain. A \u003cstrong\u003ethermostatic mixing valve\u003c\/strong\u003e at the outlet delivers the right temperature to hand basins and showers, while appliances that require hotter water are supplied accordingly. The tank drain valve, supplied as standard, is used during yearly maintenance scheduled outside opening hours.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s warranty\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 offers a \u003cstrong\u003e10-year commercial warranty\u003c\/strong\u003e, a \u003cstrong\u003e15-year residential warranty\u003c\/strong\u003e and a \u003cstrong\u003e2-year warranty on mechanical components\u003c\/strong\u003e. The category applicable to your establishment is confirmed in writing with the quote.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation of the Thermo 2000 TurboMax 120-9A 125 by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. For this commercial indirect water heater, our service includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eanalysis of consumption peaks, supply pressure and the electric boiler’s capacity;\u003c\/li\u003e\n\u003cli\u003eassessment of the mechanical room, floor, drain and delivery route;\u003c\/li\u003e\n\u003cli\u003eremoval of the old equipment;\u003c\/li\u003e\n\u003cli\u003econnecting the potable water in 2 1\/2 in, with pressure-reducing valve, thermostatic mixing valve and isolation valves;\u003c\/li\u003e\n\u003cli\u003econnecting to the boiler in 2 in, with circulator, check valve and air vents;\u003c\/li\u003e\n\u003cli\u003ethe relief valve, its discharge pipe and the expansion tank;\u003c\/li\u003e\n\u003cli\u003ewiring the controls, commissioning and a yearly maintenance plan.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe work with restaurant owners, hoteliers and property managers in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, Old Montreal, Dorval, Brossard, Saint-Hyacinthe, Blainville and across the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. The on-site estimate is free, the quote is written and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free quote for the Thermo 2000 TurboMax 120-9A 125.\u003c\/strong\u003e Describe your establishment, your appliances and your boiler: we will propose a clear configuration suited to your peaks.\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801428885796,"sku":"TURBOMAX120-9A 125","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_THERMO_2000_TURBOMAX120_9A_125_120_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082278"},{"product_id":"chauffe-eau-indirect-thermo-2000-doublemax-80-5-80-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"THERMO 2000 DOUBLEMAX 80-5 Indirect Water Heater (80 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eAn 80 US gallon indirect water heater for large homes heated by an electric boiler\u003c\/h2\u003e\n\u003cp\u003eA large home heated with hot water often has hot water needs to match its size: three bathrooms, a deep tub, sometimes a multigenerational unit on the ground floor. The \u003cstrong\u003eThermo 2000 DoubleMax 80-5 indirect water heater\u003c\/strong\u003e relies on the home’s \u003cstrong\u003eelectric boiler\u003c\/strong\u003e to heat an \u003cstrong\u003e80 US gallon\u003c\/strong\u003e tank through a 30.9 sq. ft. \u003cstrong\u003edouble-wall copper heat exchanger\u003c\/strong\u003e. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eFor large families and multigenerational homes\u003c\/h3\u003e\n\u003cp\u003eThe DoubleMax 80-5 comes into its own when several people use hot water at the same hour. In a home where two generations live under one roof, morning showers, the dishwasher and the washing machine add up. A family of five with a large freestanding tub is another typical example. For a more modest home, a smaller tank from the same series is often enough; we make the comparison with you during the visit.\u003c\/p\u003e\n\u003cp\u003eThis tank works with an electric boiler already in place or installed at the same time, as part of a radiant floor project or the replacement of an old heating system.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 80 US gallons\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e double-wall copper piping in parallel helicoidal lines, exchange surface of 30.9 sq. ft.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum domestic hot water flow:\u003c\/strong\u003e 15 gpm, to be reduced for high-temperature and continuous-flow applications\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum pressure:\u003c\/strong\u003e 150 psi\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBoiler connection:\u003c\/strong\u003e 1 1\/2 in NPT male\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDrain valve:\u003c\/strong\u003e ¾ in brass ball valve, 150 psi maximum\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e height 73 3\/4 in, diameter 24 in\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 355 lb (440 lb shipping)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCompliance:\u003c\/strong\u003e copper components meet the low lead requirements and the NSF 61 standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe reserve fills the tub, the boiler handles the rest\u003c\/h3\u003e\n\u003cp\u003eThermo 2000’s values read as \u003cstrong\u003efirst hour \/ continuous\u003c\/strong\u003e, in US gallons per hour, with cold water at 40 °F and boiler water at 180 °F. The gap between the two figures shows the role of the tank. With a 50,000 BTU\/h (15 kW) boiler, the DoubleMax 80-5 delivers 166 \/ 86 US gallons at 110 °F: the first hour is much more generous than the continuous rate, because the 80 US gallons already hot add to what the boiler produces during that time.\u003c\/p\u003e\n\u003cp\u003eThat is exactly what a large tub needs. It fills from the stored water, in a few minutes, without waiting for the boiler. Once the reserve is drawn down, continuous production takes over, then the tank rebuilds while the household sleeps or is at work.\u003c\/p\u003e\n\n\u003ch3\u003eWhat boiler capacity changes\u003c\/h3\u003e\n\u003cp\u003eThe same tank produces much more with a stronger boiler. Here are three lines from the manufacturer’s table, at 110 °F, 140 °F and 160 °F (first hour \/ continuous):\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e50,000 BTU\/h (15 kW):\u003c\/strong\u003e 166 \/ 86 at 110 °F; 92 \/ 60 at 140 °F; 74 \/ 60 at 160 °F\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e100,000 BTU\/h (29 kW):\u003c\/strong\u003e 252 \/ 172 at 110 °F; 152 \/ 120 at 140 °F; 134 \/ 120 at 160 °F\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e150,000 BTU\/h (44 kW):\u003c\/strong\u003e 338 \/ 258 at 110 °F; 213 \/ 181 at 140 °F; 194 \/ 181 at 160 °F\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAn electric boiler is first sized to heat the house. We start from that capacity to tell you what the DoubleMax 80-5 will really deliver, rather than quoting the most flattering line of the table. If a gap remains between your needs and the expected output, we discuss it before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eA double-wall copper heat exchanger\u003c\/h3\u003e\n\u003cp\u003eThe DoubleMax exchanger is made of \u003cstrong\u003edouble-wall\u003c\/strong\u003e copper pipes, wound in parallel helicoidal lines. Two thicknesses of metal separate the boiler water from the potable water. This design is valued when the heating water contains an additive such as antifreeze, or when the inspection requires double separation. The copper components meet the NSF 61 standard and the low lead requirements for potable water.\u003c\/p\u003e\n\n\u003ch3\u003eA tall tank: check the free height\u003c\/h3\u003e\n\u003cp\u003eThe DoubleMax 80-5 is 73 3\/4 in high and 24 in in diameter. It is a slender format that takes little floor space but requires enough free height under the joists, ducts and piping, not forgetting the space needed above for the fittings. We measure the mechanical room or basement before confirming the model. The tank weighs 355 lb, plus the weight of the water: it must sit on a solid, level floor, near a drain.\u003c\/p\u003e\n\n\u003ch3\u003eControls, priority and temperature\u003c\/h3\u003e\n\u003cp\u003eThe tank control is connected to the electric boiler, usually with \u003cstrong\u003ehot water priority\u003c\/strong\u003e. The boiler connection is 1 1\/2 in NPT male; the size of the potable water connections is confirmed with the manufacturer’s sheet at the quote stage. If you choose to store water at 140 °F or more, a \u003cstrong\u003ethermostatic mixing valve\u003c\/strong\u003e brings the water delivered to the taps back to a safe temperature. According to Thermo 2000, the 15 gpm maximum flow must be reduced for high-temperature and continuous-flow applications; we take this into account when choosing the piping.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s warranty\u003c\/h3\u003e\n\u003cp\u003eIn \u003cstrong\u003eresidential use\u003c\/strong\u003e, Thermo 2000 provides a \u003cstrong\u003e15-year warranty\u003c\/strong\u003e on the tank and copper coils. In \u003cstrong\u003ecommercial use\u003c\/strong\u003e, this warranty is \u003cstrong\u003e10 years\u003c\/strong\u003e. Mechanical parts are warranted for \u003cstrong\u003e2 years\u003c\/strong\u003e. The applicable terms are confirmed in writing with the quote.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation of the Thermo 2000 DoubleMax 80-5 by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal, active in heating, ventilation and air conditioning for more than fifteen years and holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Our work includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eassessment of your hot water needs, the electric boiler’s capacity and the free height;\u003c\/li\u003e\n\u003cli\u003eremoval and disposal of the old water heater;\u003c\/li\u003e\n\u003cli\u003ecold and hot water connections, with thermostatic mixing valve and shut-off valves;\u003c\/li\u003e\n\u003cli\u003econnecting the exchanger to the boiler in 1 1\/2 in, with circulator or zone valve, check valve and air vent;\u003c\/li\u003e\n\u003cli\u003ethe relief valve, its discharge pipe and, if needed, an expansion tank;\u003c\/li\u003e\n\u003cli\u003ewiring the control and setting hot water priority;\u003c\/li\u003e\n\u003cli\u003ecommissioning and a clear explanation of yearly maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, Boucherville, Saint-Bruno, Vaudreuil-Dorion, Mirabel, Terrebonne and the entire \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. The on-site estimate is free, the quote is written and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free quote for the Thermo 2000 DoubleMax 80-5.\u003c\/strong\u003e Send us a photo of your electric boiler and the height of your basement: we will confirm the right format before ordering.\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801429213476,"sku":"DOUBLEMAX 80-5","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_THERMO_2000_DOUBLEMAX_80_5_80_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082266"},{"product_id":"chauffe-eau-indirect-thermo-2000-turbomax120-9a-200-120-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"THERMO 2000 TURBOMAX120-9A 200 Indirect Water Heater (120 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eA 120 US gallon indirect water heater designed for a 200 psi maximum pressure\u003c\/h2\u003e\n\u003cp\u003eIn a residential tower, an institutional building or an industrial site, water often circulates at a higher pressure than in a house, pushed by a booster pump to reach the upper floors or supply demanding equipment. The \u003cstrong\u003eThermo 2000 TurboMax 120-9A 200 indirect water heater\u003c\/strong\u003e is made for these networks: its maximum pressure reaches \u003cstrong\u003e200 psi\u003c\/strong\u003e. It combines a \u003cstrong\u003e120 US gallon\u003c\/strong\u003e tank, a \u003cstrong\u003e58.9 sq. ft. copper coil system\u003c\/strong\u003e and 2 1\/2 in potable water connections, with an \u003cstrong\u003eelectric boiler\u003c\/strong\u003e as the heat source. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhy maximum pressure matters in large buildings\u003c\/h3\u003e\n\u003cp\u003eEvery unit connected to a building’s water network must withstand the pressure in it, including during peaks and water hammer. In a tall building, pressure is higher on the lower floors, where the mechanical room is usually located. A tank with a 200 psi maximum pressure offers a comfortable margin under these conditions. It also allows hot water production to be installed on the high-pressure side of the network when the design requires it, rather than multiplying pressure-reducing valves.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 120 US gallons\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum pressure:\u003c\/strong\u003e 200 psi\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e high-exchange-capacity copper coils, surface of 58.9 sq. ft.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWater at 110 °F:\u003c\/strong\u003e maximum exchange capacity of 1,165,000 BTU\/h (341 kW); 2,122 US GPH first hour; 2,002 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWater at 140 °F:\u003c\/strong\u003e maximum exchange capacity of 820,000 BTU\/h (240 kW); 1,038 US GPH first hour; 990 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWater at 160 °F:\u003c\/strong\u003e maximum exchange capacity of 545,000 BTU\/h (160 kW); 569 US GPH first hour; 549 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConditions:\u003c\/strong\u003e domestic cold water at 40 °F, boiler water at 180 °F\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum domestic hot water flow:\u003c\/strong\u003e 27 gpm\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e potable water 2 1\/2 in male sweat; boiler 2 in NPT male\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e height 76 3\/4 in, diameter 28 in\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 540 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eResidential towers, institutions and industrial buildings\u003c\/h3\u003e\n\u003cp\u003eThis model is aimed at buildings where both pressure and demand are high. A residential tower whose mechanical room is in the basement, a healthcare or education facility whose network is kept under pressure by a booster pump, an industrial building where hot water supplies washing stations. In each of these cases, the 120 US gallon reserve absorbs the peaks and the exchanger keeps production going as long as the electric boiler supplies the necessary heat. The 27 gpm maximum flow and the 2 1\/2 in connections suit large-diameter distribution.\u003c\/p\u003e\n\n\u003ch3\u003eA pressure margin does not replace safety devices\u003c\/h3\u003e\n\u003cp\u003eA high maximum pressure does not remove the need for safety devices. The relief valve is chosen according to the tank’s maximum pressure and capacity, an expansion tank absorbs the expansion of the heated water, and a pressure-reducing valve remains useful when supply pressure exceeds what the other components of the installation accept. We measure the real pressure, including while the booster pump is running, before finalizing the design.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the 58.9 sq. ft. exchanger can deliver\u003c\/h3\u003e\n\u003cp\u003eAccording to Thermo 2000, the high-exchange-capacity copper coil system heats water instantly. Its exchanger can transfer up to 1,165,000 BTU\/h (341 kW) for water at 110 °F, which gives 2,122 US GPH in the first hour and 2,002 US GPH continuous at full capacity. These values assume the boiler supplies that output, which is not the case for every electric boiler; the real continuous output follows the boiler’s capacity and therefore the building’s electrical service. The manufacturer adds that the values must be reduced for high-temperature and continuous-flow applications. Our quote states the expected output with your boiler.\u003c\/p\u003e\n\n\u003ch3\u003eA 540 lb tank to plan for\u003c\/h3\u003e\n\u003cp\u003eThe TurboMax 120-9A 200 weighs 540 lb empty and is 76 3\/4 in high and 28 in in diameter. In a tower, delivery sometimes goes through a freight elevator or a service entrance; in an industrial building, through a garage door. We plan the route, the handling equipment, the floor capacity once the tank is filled, access to a drain and the service space around the fittings and drain valve.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s warranty\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 offers a \u003cstrong\u003e10-year commercial warranty\u003c\/strong\u003e, a \u003cstrong\u003e15-year residential warranty\u003c\/strong\u003e and a \u003cstrong\u003e2-year warranty on mechanical components\u003c\/strong\u003e. The category applicable to your building is confirmed in writing with the quote.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation of the Thermo 2000 TurboMax 120-9A 200 by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work. For this high-pressure indirect water heater, our work includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the supply pressure, including while the booster pump is running;\u003c\/li\u003e\n\u003cli\u003eanalysis of hot water needs and of the electric boiler’s capacity;\u003c\/li\u003e\n\u003cli\u003eplanning of delivery, handling and positioning;\u003c\/li\u003e\n\u003cli\u003econnecting the potable water in 2 1\/2 in, with thermostatic mixing valve and isolation valves;\u003c\/li\u003e\n\u003cli\u003econnecting to the boiler in 2 in, with circulator, check valve and air vents;\u003c\/li\u003e\n\u003cli\u003ethe relief valve, its discharge pipe, the expansion tank and, if needed, the pressure-reducing valve;\u003c\/li\u003e\n\u003cli\u003ewiring the controls, commissioning and a yearly maintenance plan.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe work with property managers, institutions and companies in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, downtown, Nuns’ Island, Saint-Laurent, Boucherville, Terrebonne and across the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. The on-site estimate is free, the quote is written and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free quote for the Thermo 2000 TurboMax 120-9A 200.\u003c\/strong\u003e Send us your network pressure and your boiler’s specifications: we will propose a safe, complete configuration.\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801431408932,"sku":"TURBOMAX120-9A 200","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_THERMO_2000_TURBOMAX120_9A_200_120_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082278"},{"product_id":"chauffe-eau-indirect-thermo-2000-doublemax-120-9-119-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"THERMO 2000 DOUBLEMAX 120-9 Indirect Water Heater (119 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eA 119 US gallon indirect water heater for buildings and businesses heated by an electric boiler\u003c\/h2\u003e\n\u003cp\u003eIn an apartment building, a daycare or a business heated by an \u003cstrong\u003eelectric boiler\u003c\/strong\u003e, domestic hot water can come from the same source as the heating. The \u003cstrong\u003eThermo 2000 DoubleMax 120-9 indirect water heater\u003c\/strong\u003e is designed for these shared needs: a \u003cstrong\u003e119 US gallon\u003c\/strong\u003e tank, a 55.6 sq. ft. \u003cstrong\u003edouble-wall copper heat exchanger\u003c\/strong\u003e and an output that climbs with the boiler’s capacity. AirGreen installs it in buildings in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eA tank designed for shared needs\u003c\/h3\u003e\n\u003cp\u003eThe DoubleMax 120-9 is not a single-family home unit. It is aimed at buildings where several households or several stations use hot water at the same time: a building of a few units with centralized hot water, a daycare washing dishes and hands all day long, a clinic, a hair salon, a fitness centre with a few showers. In these buildings, the electric boiler that heats the premises can also produce hot water, which avoids multiplying separate electric water heaters and the circuits that feed them.\u003c\/p\u003e\n\u003cp\u003eThe tank is always selected from the real demand. We count the units, the appliances and the consumption peaks before proposing this model or another configuration.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 119 US gallons\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e double-wall copper piping in parallel helicoidal lines\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eExchange surface:\u003c\/strong\u003e 55.6 sq. ft.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum domestic hot water flow:\u003c\/strong\u003e 27 gpm, to be reduced for high-temperature and continuous-flow applications\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum pressure:\u003c\/strong\u003e 150 psi\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBoiler connection:\u003c\/strong\u003e 2 in NPT male\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDrain valve:\u003c\/strong\u003e ¾ in brass ball valve, 150 psi maximum\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e height 76 1\/4 in, diameter 28 in\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 530 lb (610 lb shipping)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePotable water:\u003c\/strong\u003e copper components meet the low lead requirements and the NSF 61 standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOutput that follows the boiler’s capacity\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 publishes an output table ranging from a 50,000 BTU\/h (15 kW) boiler up to 900,000 BTU\/h (264 kW), for cold water at 40 °F and boiler water at 180 °F. The values read as \u003cstrong\u003efirst hour \/ continuous\u003c\/strong\u003e, in US gallons per hour. A few reference points for water delivered at 110 °F:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e100,000 BTU\/h (29 kW):\u003c\/strong\u003e 291 \/ 172\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e200,000 BTU\/h (59 kW):\u003c\/strong\u003e 463 \/ 344\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e300,000 BTU\/h (88 kW):\u003c\/strong\u003e 635 \/ 516\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e900,000 BTU\/h (264 kW):\u003c\/strong\u003e 1,668 \/ 1,549\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe message is clear: the tank and its exchanger can keep up with a high-capacity commercial electric boiler, and it is the boiler that sets the real output. In an existing building, the available capacity depends on the electrical service; we start from that figure to establish a realistic output.\u003c\/p\u003e\n\n\u003ch3\u003eThe higher temperatures of commercial uses\u003c\/h3\u003e\n\u003cp\u003eSome uses require hotter water than a shower: dishwashing, sanitary cleaning, laundry. The table also covers water delivered at 140 °F and 160 °F. With 200,000 BTU\/h (59 kW), the DoubleMax 120-9 gives 289 \/ 241 at 140 °F and 261 \/ 241 at 160 °F. Above 400,000 BTU\/h (117 kW), the manufacturer no longer publishes a value at 160 °F, and above 650,000 BTU\/h (191 kW), no value at 140 °F: these combinations are not covered, and we size the installation within the published values. Thermo 2000 also points out that the 27 gpm maximum flow must be reduced for high-temperature and continuous-flow applications.\u003c\/p\u003e\n\n\u003ch3\u003eDouble wall: extra protection for potable water\u003c\/h3\u003e\n\u003cp\u003eThe exchanger is made of \u003cstrong\u003edouble-wall\u003c\/strong\u003e copper pipes. In a building where the heating loop water may contain an additive, or when the engineer, inspector or insurer requires double separation, this design meets the requirement without adding an external exchanger. The copper components comply with the NSF 61 standard for potable water plumbing products.\u003c\/p\u003e\n\n\u003ch3\u003eDistribution and delivered temperature\u003c\/h3\u003e\n\u003cp\u003eIn a building, hot water travels long distances. We design the distribution with a \u003cstrong\u003ethermostatic mixing valve\u003c\/strong\u003e at the tank outlet, so the water can be stored hotter while a safe temperature is delivered to the units, and we add a recirculation loop when needed so hot water reaches the farthest points quickly. The size of the potable water connections is confirmed with the manufacturer’s sheet at the quote stage, since it guides the piping diameter.\u003c\/p\u003e\n\n\u003ch3\u003eHandling and mechanical room\u003c\/h3\u003e\n\u003cp\u003eThe tank weighs 530 lb empty, plus the weight of the water. At 76 1\/4 in high and 28 in in diameter, the delivery route, the free height and the floor capacity must be planned. The boiler connection is 2 in NPT male: we plan the circulator, isolation valves and air vents accordingly. The brass ball drain valve makes yearly maintenance easier.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s warranty\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 offers a \u003cstrong\u003e10-year commercial warranty\u003c\/strong\u003e on the tank and copper coils and a \u003cstrong\u003e15-year residential warranty\u003c\/strong\u003e on these same components. Mechanical parts are warranted for \u003cstrong\u003e2 years\u003c\/strong\u003e. The category applicable to your building is confirmed in writing with the quote.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation of the Thermo 2000 DoubleMax 120-9 by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work. For a commercial indirect water heater, our work includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eanalysis of the hot water demand and of the electric boiler’s capacity;\u003c\/li\u003e\n\u003cli\u003eassessment of the mechanical room, floor, drain and delivery route;\u003c\/li\u003e\n\u003cli\u003eremoval of the old water heaters or tanks;\u003c\/li\u003e\n\u003cli\u003econnecting the exchanger to the boiler in 2 in, with circulator, isolation valves and air vents;\u003c\/li\u003e\n\u003cli\u003epotable water connections, the thermostatic mixing valve and, if needed, the recirculation loop;\u003c\/li\u003e\n\u003cli\u003ethe relief valve, its discharge pipe and the expansion tank;\u003c\/li\u003e\n\u003cli\u003ewiring the controls, commissioning and a yearly maintenance plan.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe work with owners, property managers and business owners in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, Brossard, Saint-Laurent, Pointe-Claire, Terrebonne, Saint-Jérôme and the entire \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. Free on-site estimate, written quote and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free quote for the Thermo 2000 DoubleMax 120-9.\u003c\/strong\u003e Send us your boiler’s capacity and the number of units or stations to serve: we will propose a priced, realistic configuration.\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801431867684,"sku":"DOUBLEMAX 120-9","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_THERMO_2000_DOUBLEMAX_120_9_119_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082266"},{"product_id":"chauffe-eau-indirect-thermo-2000-doublemax-120-9a-120-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"THERMO 2000 DOUBLEMAX 120-9A Indirect Water Heater (120 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eA 120 US gallon indirect water heater in ASME version for institutional and commercial buildings\u003c\/h2\u003e\n\u003cp\u003eIn a seniors’ residence, an early childhood centre, a hotel or a commercial kitchen, hot water is an essential service and the tank that produces it is often subject to specific requirements from the engineer or the insurer. The \u003cstrong\u003eThermo 2000 DoubleMax 120-9A indirect water heater\u003c\/strong\u003e fits this context: a \u003cstrong\u003e120 US gallon\u003c\/strong\u003e tank, a 55.6 sq. ft. \u003cstrong\u003edouble-wall copper heat exchanger\u003c\/strong\u003e and a maximum pressure of 125 psi stated for the \u003cstrong\u003eASME version\u003c\/strong\u003e. It is fed by an \u003cstrong\u003eelectric boiler\u003c\/strong\u003e. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhy choose the 120-9A version\u003c\/h3\u003e\n\u003cp\u003eOn the DoubleMax 120-9A specification sheet, the maximum pressure is stated as \u003cstrong\u003e125 psi (ASME)\u003c\/strong\u003e. The American Society of Mechanical Engineers code governs the design of pressure vessels; in many commercial and institutional projects, the engineer’s drawings or the insurer’s conditions require a tank of this type. Choosing the right version from the start avoids reordering and a site delay. We check this requirement with you before quoting.\u003c\/p\u003e\n\n\u003ch3\u003eManaging a 125 psi maximum pressure\u003c\/h3\u003e\n\u003cp\u003eThe maximum working pressure of this model is 125 psi. In some areas, the municipal supply pressure or that of a booster pump can come close to it, especially on the lower floors of a building. We measure the pressure at the water entrance and install a \u003cstrong\u003epressure-reducing valve\u003c\/strong\u003e when needed. The relief valve is chosen according to this maximum pressure and the tank volume, and an expansion tank absorbs the expansion of the heated water. These three components work as a whole: they protect the tank, the piping and the users.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 120 US gallons\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e double-wall copper in parallel helicoidal lines, exchange surface of 55.6 sq. ft.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum pressure:\u003c\/strong\u003e 125 psi (ASME)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum domestic hot water flow:\u003c\/strong\u003e 27 gpm, value to be reduced for high-temperature and continuous-flow applications\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eBoiler connection:\u003c\/strong\u003e 2 in NPT male\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDrain valve:\u003c\/strong\u003e ¾ in brass ball valve, maximum working pressure of 150 psi\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDiameter:\u003c\/strong\u003e 28 in\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 530 lb (610 lb shipping)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePotable water:\u003c\/strong\u003e copper components meet the NSF 61 standard and the low lead requirements\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eOutput at commercial temperatures\u003c\/h3\u003e\n\u003cp\u003eThermo 2000’s table gives output in US gallons per hour, as \u003cstrong\u003efirst hour \/ continuous\u003c\/strong\u003e, according to boiler capacity, with cold water at 40 °F and boiler water at 180 °F. In an institutional building or a kitchen, the 140 °F and 160 °F columns are often the most useful:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e150,000 BTU\/h (44 kW):\u003c\/strong\u003e 228 \/ 181 at 140 °F; 201 \/ 181 at 160 °F; 377 \/ 258 at 110 °F\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e250,000 BTU\/h (73 kW):\u003c\/strong\u003e 349 \/ 301 at 140 °F; 321 \/ 301 at 160 °F; 549 \/ 430 at 110 °F\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e400,000 BTU\/h (117 kW):\u003c\/strong\u003e 530 \/ 482 at 140 °F; 502 \/ 482 at 160 °F; 807 \/ 688 at 110 °F\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eReal output therefore depends on the electric boiler and on the building’s electrical service. We establish these two figures first, then read the table at the line that truly matches your installation.\u003c\/p\u003e\n\n\u003ch3\u003eWhere the DoubleMax 120-9A fits\u003c\/h3\u003e\n\u003cp\u003eA seniors’ residence concentrates baths and care in the morning. An early childhood centre washes dishes and hands all day long. A small hotel sees its guests shower at the same hour. A commercial kitchen needs hotter water for the pot sink. In each of these cases, the 120 US gallon reserve covers the peak while the electric boiler maintains production. A thermostatic mixing valve then delivers the right temperature for each use.\u003c\/p\u003e\n\n\u003ch3\u003eA double-wall exchanger for potable water\u003c\/h3\u003e\n\u003cp\u003eThe exchanger’s copper pipes are \u003cstrong\u003edouble-wall\u003c\/strong\u003e: two thicknesses of metal separate the boiler water from the potable water. This design is often requested in public buildings, or when the heating loop contains an additive. It comes on top of the copper components’ compliance with the NSF 61 standard.\u003c\/p\u003e\n\n\u003ch3\u003eDelivery and location\u003c\/h3\u003e\n\u003cp\u003eThe tank weighs 530 lb empty and measures 28 in in diameter. Its exact height is confirmed with the manufacturer’s order sheet; we compare it with the free height of your mechanical room before ordering. The delivery route, the floor capacity once the tank is filled and access to a drain are checked during the visit. The boiler connection is 2 in NPT male; the size of the potable water connections is confirmed with the same sheet.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s warranty\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 provides a \u003cstrong\u003e10-year commercial warranty\u003c\/strong\u003e and a \u003cstrong\u003e15-year residential warranty\u003c\/strong\u003e on the tank and copper coils, as well as a \u003cstrong\u003e2-year warranty\u003c\/strong\u003e on mechanical parts. The category that applies to your building is specified in writing with the quote.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation of the Thermo 2000 DoubleMax 120-9A by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. For this tank, our service includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003econfirmation of the ASME requirement, the supply pressure and the electric boiler’s capacity;\u003c\/li\u003e\n\u003cli\u003eassessment of the mechanical room, free height, floor and delivery route;\u003c\/li\u003e\n\u003cli\u003eremoval of the old equipment;\u003c\/li\u003e\n\u003cli\u003econnecting the exchanger to the boiler in 2 in, with circulator, isolation valves and air vents;\u003c\/li\u003e\n\u003cli\u003epotable water connections, the pressure-reducing valve, the thermostatic mixing valve and the expansion tank;\u003c\/li\u003e\n\u003cli\u003ethe relief valve and its discharge pipe to the drain;\u003c\/li\u003e\n\u003cli\u003ewiring the controls, commissioning and a yearly maintenance plan.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe work with institutions, property managers and businesses in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, Brossard, Châteauguay, Saint-Jean-sur-Richelieu, Sainte-Thérèse, Repentigny and across the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. The on-site estimate is free, the quote is written and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free quote for the Thermo 2000 DoubleMax 120-9A.\u003c\/strong\u003e Attach your engineer’s or insurer’s requirements: we will reply with a complete, compliant configuration.\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801431900452,"sku":"DOUBLEMAX 120-9A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_THERMO_2000_DOUBLEMAX_120_9A_120_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082266"},{"product_id":"chaudiere-electrique-thermo-2000-mini-bth-3-3-kw-240v","title":"THERMO 2000 Mini BTH 3 Electric Boiler | 3 kW - 240V","description":"\u003ch2\u003e3 kW of gentle hot water heat, in a boiler that fits on a wall\u003c\/h2\u003e\n\u003ch3\u003eThe smallest Mini BTH, for small zones\u003c\/h3\u003e\n\u003cp\u003eNot every heating zone needs a big boiler. A radiant floor in the basement bathroom, a room added at the back of the house, a small condo heated by hydronic baseboards: for these modest loads, Thermo 2000’s Mini BTH 3 does the job with a single 3 kW element, or 10,236 BTU\/h at 240 V.\u003c\/p\u003e\n\u003cp\u003eIts body holds only 1 US gal of water. Thermo 2000 describes it as very compact, multi-position and quiet, designed for condos, houses, basements and garages. It mounts on the wall and connects through four 3\/4 in female NPT connections. The manufacturer also presents it as backup for a heat pump, a geothermal or a solar system, with no GHG emissions.\u003c\/p\u003e\n\u003ch3\u003eA simple electrical connection\u003c\/h3\u003e\n\u003cp\u003eAt 240 V, the Mini BTH 3 draws 12.5 A. Thermo 2000 specifies a 20 A breaker and Cu 12 or Al 10 wire. In a \u003cstrong\u003eMontreal\u003c\/strong\u003e condo or a \u003cstrong\u003eLaval\u003c\/strong\u003e home where the panel is already well filled, this small load fits in more easily than a larger boiler. If the building is supplied at 208 V, output becomes 2.2 kW (10.9 A): we take that into account from the estimate.\u003c\/p\u003e\n\u003cp\u003eThe control is deliberately simple: an aquastat sets the water temperature, an indicator light shows when the element is heating, a switch turns the appliance on or off, and a 24 V supply serves the thermostat and accessories. There is no outdoor sensor. Two high temperature limits protect the appliance: automatic at 208 °F (98 °C) and manual at 227 °F (108 °C).\u003c\/p\u003e\n\u003ch3\u003eWhat to plan around the boiler\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 supplies the 30 psi relief valve, the drain valve and the temperature and pressure gauge. The circulator and expansion tank are not included: they are chosen for the circuit to be heated, and we list them in the quote. The maximum working pressure is 30 psi (207 kPa).\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eWe first come for a free on-site estimate: area to heat, type of distribution, electrical panel, wall location. You then receive a written quote. On installation day, our technicians mount the boiler, install the circulator and expansion tank, connect the water circuit, make the electrical and thermostat connections, then fill, purge and check operation with you.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Thermo 2000 warrants the tank for 15 years and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eHeat your small zone\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe install the Mini BTH in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Ask for your free estimate: the quote is in writing, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801441534244,"sku":"MINI BTH 3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_MINI_BTH_3_KW_240V_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082264"},{"product_id":"chaudiere-electrique-thermo-2000-mini-bth-ultra-3-3-kw-240v","title":"THERMO 2000 Mini BTH Ultra 3 Electric Boiler | 3 kW - 240V","description":"\u003ch2\u003e3 kW of hot-water heat that fits on a wall and on a 20 A circuit\u003c\/h2\u003e\n\u003ch3\u003eThe smallest Mini ULTRA, for a single loop\u003c\/h3\u003e\n\u003cp\u003eThe Mini ULTRA 3 is the entry size of Thermo 2000’s Mini ULTRA series. This wall-mounted electric boiler heats the water of a hydronic circuit: radiant floor, radiators or hot-water baseboards. It runs on a single 3 kW element, in one stage, and produces 10,236 BTU\/h at 240 V according to the manufacturer.\u003c\/p\u003e\n\u003cp\u003eThis size is meant for projects where the heating load stays small. Think of a finished basement whose slab carries a radiant floor, a garage you want to keep at a steady temperature, a small condo heated by hydronic baseboards, or an added room with its own loop. Thermo 2000 also presents it as a possible back-up for an air-to-water heat pump or a geothermal system.\u003c\/p\u003e\n\u003cp\u003eAll the heat is electric: the unit produces no GHG emissions on site. It holds only 1 US gal of water and weighs 47 lb when shipped. It hangs on a wall, in the basement or in a mechanical closet, and leaves the floor free.\u003c\/p\u003e\n\u003ch3\u003eAn electrical load that is easy to fit in\u003c\/h3\u003e\n\u003cp\u003eIn many homes in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e or \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the electrical panel has little room left. The Mini ULTRA 3 draws 12.5 A at full output, and Thermo 2000 specifies a 20 A breaker with Cu 12 or Al 10 wire at 240 V. If the building is supplied at 208 V, as some apartment buildings are, the output drops to 2.2 kW (10.9 A). We factor that in from the load calculation on.\u003c\/p\u003e\n\u003cp\u003eThe T2 UltraSmart controller handles day-to-day comfort. It offers presets by distribution system, then adjusts the water temperature to the outdoor temperature with the supplied sensor, using three curves (MIN, STD and MAX). In mild weather it shuts the heat off; when a room needs to warm up faster, Boost mode takes over. The water temperature can be set from 50 °F to 190 °F.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eEverything starts with a free on-site estimate. We look at the hot-water loop, the electrical panel and the wall the boiler will hang on, then give you a written quote. It lists the circulator and expansion tank to plan for, since they are not among the parts Thermo 2000 supplies.\u003c\/p\u003e\n\u003cp\u003eOn installation day, our technicians mount the unit and connect it to the loop through its 3\/4 in NPT connections. They install the supplied 30 psi relief valve, temperature and pressure gauge and drain valve, mount the outdoor sensor, then make the electrical connection. AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. We fill and purge the loop, set the controller curve and show you how to read the display.\u003c\/p\u003e\n\u003cp\u003eWe are a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years. Our crews work across Greater \u003cstrong\u003eMontreal\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e as well as the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet’s talk about your project\u003c\/h3\u003e\n\u003cp\u003eA basement floor to warm up, a garage to keep above freezing or a small loop to replace: tell us about your situation and we will tell you whether the Mini ULTRA 3 is the right size.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate: we confirm the size, you receive a written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available to spread out your payments.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801442615588,"sku":"MINI BTH ULTRA 3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_MINI_ULTRA_3_KW_240V_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082264"},{"product_id":"chaudiere-electrique-thermo-2000-mini-bth-4-5-4-5-kw-240v","title":"THERMO 2000 Mini BTH 4.5 Electric Boiler | 4.5 kW - 240V","description":"\u003ch2\u003eA 4.5 kW wall-mounted electric backup for your heat pump or geothermal system\u003c\/h2\u003e\n\u003ch3\u003eWhen the main source needs support\u003c\/h3\u003e\n\u003cp\u003eA heat pump, a geothermal system or solar collectors heating a water loop do most of the work, but there are times when they are no longer enough. You then need a simple, reliable electric source that takes over on the same loop. Thermo 2000 designed the Mini BTH for that role, and the 4.5 kW size suits homes where the backup load stays modest.\u003c\/p\u003e\n\u003cp\u003eThe Mini BTH 4.5 heats water with a single 4.5 kW element, or 15,354 BTU\/h at 240 V. Its body holds only 1 US gal of water and mounts on the wall, in several positions. On its own, it also suits a condo heated by hydronic baseboards or the radiant floor of a finished basement. Thermo 2000 points out that it runs quietly and with no GHG emissions.\u003c\/p\u003e\n\u003ch3\u003eA boiler that is simple to integrate\u003c\/h3\u003e\n\u003cp\u003eOn the electrical side, the manufacturer specifies a 240 V circuit with a 30 A breaker and Cu 10 or Al 10 wire. In buildings supplied at 208 V, common in \u003cstrong\u003eMontreal\u003c\/strong\u003e, it gives 3.4 kW (16.3 A): we check the voltage before settling on the size.\u003c\/p\u003e\n\u003cp\u003eOn the water side, it accepts 3.0 US gpm at a 10 °F temperature difference, or 1.5 US gpm at 20 °F, with negligible pressure drop according to Thermo 2000. Its four 3\/4 in female NPT connections, for inlet and outlet, simplify the tie-in to the existing loop, a point Thermo 2000 highlights for wall mounting. Water can be set from 50 °F to 190 °F (10 °C to 90 °C), at a maximum working pressure of 30 psi.\u003c\/p\u003e\n\u003cp\u003eControl is by aquastat, with an element indicator light, a switch and a 24 V supply for the thermostat and accessories. The Mini BTH has no outdoor sensor. For safety, an automatic high limit cuts out at 208 °F (98 °C) and a manual limit at 227 °F (108 °C).\u003c\/p\u003e\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eIt all starts with a free on-site estimate, where we look at the main source, the water loop, the electrical panel and the wall that will hold the boiler. You then receive a written quote that specifies the circulator and the expansion tank to add, since Thermo 2000 does not supply them.\u003c\/p\u003e\n\u003cp\u003eOur technicians mount the boiler, connect it to the loop, install the supplied 30 psi relief valve and temperature and pressure gauge, make the electrical and control connections, then fill, purge and test the backup with you. AirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Thermo 2000 warrants the tank for 15 years and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eAdd backup to your system\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe install the Mini BTH in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. The estimate is free, the quote is in writing and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801443565860,"sku":"MINI BTH 4,5","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_MINI_BTH_4_5_KW_240V_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082264"},{"product_id":"chaudiere-electrique-thermo-2000-mini-bth-ultra-4-5-4-5-kw-240v","title":"THERMO 2000 Mini BTH Ultra 4.5 Electric Boiler | 4.5 kW - 240V","description":"\u003ch2\u003e4.5 kW of hot water for a radiant floor, right from the wall\u003c\/h2\u003e\n\u003ch3\u003eWho the Mini ULTRA 4.5 is for\u003c\/h3\u003e\n\u003cp\u003eA basement with a cold floor, a workshop you would like to use in January, a plex dwelling heated by a few hot-water baseboards: these are the situations where Thermo 2000’s Mini ULTRA 4.5 belongs. This wall-mounted electric boiler runs on a single 4.5 kW element and produces 15,354 BTU\/h at 240 V, according to the manufacturer.\u003c\/p\u003e\n\u003cp\u003eIt heats the water of a hydronic circuit, whether a radiant floor, radiators or baseboards. Thermo 2000 also presents it as a back-up for a geothermal or solar system. Like the whole Mini ULTRA series, it emits no GHG on site and needs little maintenance.\u003c\/p\u003e\n\u003ch3\u003eA cold basement, a floor that stays warm\u003c\/h3\u003e\n\u003cp\u003eIn Quebec, many basements sit on a concrete slab that stays cool all winter. A radiant floor fed by a small electric boiler deals with that comfort issue at the source, without forced air and without blower noise. Thermo 2000 highlights the Mini ULTRA’s quiet operation, designed for condos, houses, basements and garages.\u003c\/p\u003e\n\u003cp\u003eThe T2 UltraSmart controller reads the supplied outdoor sensor and adjusts the water temperature to the weather, using a MIN, STD or MAX curve. A slab does not need water as hot as a cast-iron radiator does, and that is what the presets by distribution system are for. The controller also shuts the heat off in mild weather and runs a pump purge.\u003c\/p\u003e\n\u003cp\u003eOn the electrical side, plan for a dedicated 240 V circuit with a 30 A breaker and Cu 10 \/ Al 10 wire. At 208 V, the output becomes 3.4 kW (16.3 A). Whether the house is in \u003cstrong\u003eLaval\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e or in a \u003cstrong\u003eMontreal\u003c\/strong\u003e plex, we check the voltage and the panel capacity before recommending this size.\u003c\/p\u003e\n\u003ch3\u003eYour installation, step by step\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate: the water loop, the area to heat, the panel and the mounting wall.\u003c\/li\u003e\n\u003cli\u003eWritten quote, including the circulator and expansion tank, which are not among the supplied parts.\u003c\/li\u003e\n\u003cli\u003eWall mounting of the boiler, connection to the loop through the 3\/4 in female NPT connections, and installation of the 30 psi relief valve, temperature and pressure gauge and drain valve.\u003c\/li\u003e\n\u003cli\u003eElectrical connection and outdoor sensor installation. AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/li\u003e\n\u003cli\u003eFilling, purging and setting the controller for your distribution system.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe loop must respect the unit’s 30 psi maximum working pressure and provide the flow Thermo 2000 specifies: 3.0 US gpm at a 10 °F ΔT, or 1.5 US gpm at a 20 °F ΔT. We size the circulator accordingly.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years. We also install in \u003cstrong\u003eLongueuil\u003c\/strong\u003e and throughout the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGetting your quote\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer warrants the tank for 15 years and the electrical and mechanical components for 2 years. What remains is to confirm that 4.5 kW matches your space, and that is what our visit is for.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBook your free estimate, receive a written quote and, if you wish, use \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e to spread out your payments.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801445040420,"sku":"MINI BTH ULTRA 4,5","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_MINI_ULTRA_4_5_KW_240V_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082264"},{"product_id":"chaudiere-electrique-a-masse-thermique-thermo-2000-altsource-50-4-5-kw-240v","title":"THERMO 2000 AltSource 50 Thermal Mass Electric Boiler | 4.5 kW - 240V","description":"\u003ch2\u003eA 4.5 kW electric backup with 48 US gal of stored water for your renewable-energy system\u003c\/h2\u003e\n\u003ch3\u003eWhat the AltSource 50-4.5 is and who it suits\u003c\/h3\u003e\n\u003cp\u003eThermo 2000’s AltSource is not an ordinary electric boiler. Its tank holds 48 US gal of water, and the manufacturer presents it as the only high water volume electric boiler on the market. It serves as the backup source of a renewable-energy heating system: an air-to-water heat pump, a geothermal system or solar collectors do most of the work, and the AltSource adds electric heat as needed.\u003c\/p\u003e\n\u003cp\u003eThe 4.5 kW size is the smallest in the series. It runs on a single heating element, in a single stage, and produces 15,354 BTU\/h at 240 V according to Thermo 2000. It suits homes where the main source already covers most of the needs: a bungalow with radiant floor heating, a small well-insulated house, an addition tied into an existing hot-water loop.\u003c\/p\u003e\n\u003ch3\u003eA modest current draw for your electrical panel\u003c\/h3\u003e\n\u003cp\u003eIn many homes in \u003cstrong\u003eMontreal\u003c\/strong\u003e and \u003cstrong\u003eLaval\u003c\/strong\u003e, the electrical panel is already busy: range, water heater, dryer, charging station. The AltSource 50-4.5 needs only a 30 A breaker and 10-gauge copper wire, according to the manufacturer’s data. If the building has a 208 V supply, output drops to 3.4 kW (16.3 A); we take this into account from the estimate onward.\u003c\/p\u003e\n\u003cp\u003eThe T2 UltraSmart controller is included. With the supplied outdoor sensor, it adjusts output and water temperature to the weather, shuts heating off in warm weather and offers a Boost mode. Two operating modes are available: standalone electric, the default setting, or automatic transfer controlled by an external contact.\u003c\/p\u003e\n\u003cp\u003eThe unit is 56 7\/16 in high and 22 in in diameter, and 25 1\/2 in deep with the door. It weighs 280 lb, plus the water in the tank once filled: we choose a location with you in the basement or mechanical room, on a floor that can carry that weight.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eEverything starts with a free on-site estimate. We look at the main source, the hot-water loop (radiant floor, baseboards or radiators), the electrical panel and the available space. You then receive a written quote. It lists the circulator and expansion tank to plan for, since they are not among the parts Thermo 2000 supplies. The manufacturer recommends a #30 tank for a radiant floor or baseboards, and a #60 for cast-iron radiators.\u003c\/p\u003e\n\u003cp\u003eOn installation day, our technicians set the unit in place and connect it to the loop through its 1 in NPT fittings. They install the supplied 30 psi relief valve, automatic air vent and outdoor sensor, then make the electrical connection. We fill and purge the system, set the controller and check operation with you.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. For its part, Thermo 2000 covers the tank for 15 years in residential use and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003ePlan your electric backup\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe install the AltSource in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Ask for your free estimate: you receive a clear written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available so you can go ahead without waiting.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801449595172,"sku":"ALTSOURCE50-4,5","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_ALTSOURCE_50_4_5_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-a-masse-thermique-thermo-2000-altsource-70-4-5-kw-240v","title":"THERMO 2000 AltSource 70 Thermal Mass Electric Boiler | 4.5 kW - 240V","description":"\u003ch2\u003e71 US gal of thermal mass and 4.5 kW of backup for homes that rely on renewable energy\u003c\/h2\u003e\n\u003ch3\u003eA large water reserve, a single element\u003c\/h3\u003e\n\u003cp\u003eThermo 2000’s AltSource 70-4.5 is a thermal mass electric boiler: its tank holds 71 US gal of water. The manufacturer presents it as the only high water volume electric boiler on the market and designs it for a specific role, as the backup source of a renewable-energy heating system. Geothermal, an air-to-water heat pump or solar collectors handle most of the heating; the AltSource tops it up.\u003c\/p\u003e\n\u003cp\u003eIn this size, the electric side is deliberately small. A single 4.5 kW element, in a single stage, delivers 15,354 BTU\/h at 240 V. It is the leanest combination of the AltSource 70: this model’s full water reserve for the lowest current draw.\u003c\/p\u003e\n\u003ch3\u003eThe homes where this size makes sense\u003c\/h3\u003e\n\u003cp\u003eThis size suits owners who have invested in a well-sized renewable source and want a discreet electric backup. A well-insulated house in \u003cstrong\u003eLongueuil\u003c\/strong\u003e with a radiant floor tied to geothermal, a \u003cstrong\u003eSouth Shore\u003c\/strong\u003e property with solar thermal collectors, a new house with an air-to-water heat pump: in each case, the main source does most of the work and the AltSource keeps the home comfortable when it falls short.\u003c\/p\u003e\n\u003cp\u003eOn the electrical side, Thermo 2000 lists a 30 A breaker and Cu 10 \/ Al 10 wire gauge at 240 V. At 208 V, output drops to 3.4 kW (16.3 A). The T2 UltraSmart controller, supplied with its outdoor sensor, modulates output and water temperature to the weather, shuts heating off in warm weather and offers a Boost mode.\u003c\/p\u003e\n\u003ch3\u003ePreparing the location\u003c\/h3\u003e\n\u003cp\u003eA 71 US gal reserve takes up space and weight. The unit measures 24 in in diameter and 28 in deep with the door, and weighs 380 lb before the water is added. We check the access path to the mechanical room and the strength of the floor. The loop connects through 1 1\/4 in male NPT fittings and operates at a maximum pressure of 30 psi. For the expansion tank, Thermo 2000 recommends a #60 with baseboards or a radiant floor, and a #90 with cast-iron radiators.\u003c\/p\u003e\n\u003cp\u003eIf you also want to preheat domestic water, Thermo 2000 offers an optional 26.2 sq ft parallel copper coil heat exchanger. We discuss it from the first visit.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eThe on-site estimate is free and the written quote details the unit, the circulator, the expansion tank and the electrical work. Our technicians then install the boiler, connect it to the loop, mount the outdoor sensor, make the electrical connection, fill and purge the system, then set the controller. Thermo 2000 covers the tank for 15 years in residential use and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01.\u003c\/p\u003e\n\u003ch3\u003eAsk for your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe serve Montreal, Laval, Longueuil, the North Shore and the South Shore. Tell us about your renewable source: we send you a written quote for the AltSource 70, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801450447140,"sku":"ALTSOURCE70-4,5","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_ALTSOURCE_70_4_5_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-avec-eau-chaude-integree-thermo-2000-combomax-ultra-50-4-5-kw-240v","title":"THERMO 2000 ComboMax Ultra 50 Electric Boiler with Integrated Hot Water | 4.5 kW - 240V","description":"\u003ch2\u003eHot-water heating and the home’s hot water, in the space of a single water heater\u003c\/h2\u003e\n\u003ch3\u003eOne appliance, two jobs\u003c\/h3\u003e\n\u003cp\u003eThermo 2000’s ComboMax Ultra combines an electric boiler and an instantaneous water heater. The tank holds the heating water, 48 US gal in the 50 model. Parallel copper coils sit in that water: drinking water flows through them and heats up on the way, with no domestic hot water stored. According to the manufacturer, hot water arrives in under 7 seconds, and the absence of storage reduces the risk of Legionella.\u003c\/p\u003e\n\u003cp\u003eThe COMBOU50-4,5 is the smallest size in the series: a single 4.5 kW element on one stage, delivering 15,354 BTU\/h at 240 V. It suits a condo, a small bungalow or a well-insulated dwelling heated by radiant floors or radiators, where heating needs are modest. Thermo 2000 publishes an output of 50 US gal of hot water in 10 minutes and 72 US gal in one hour, for water delivered at 110 °F, cold water at 40 °F and boiler water at 180 °F.\u003c\/p\u003e\n\u003ch3\u003eWhy this size slips easily into a local home\u003c\/h3\u003e\n\u003cp\u003eIn many homes in \u003cstrong\u003eMontreal\u003c\/strong\u003e and \u003cstrong\u003eLaval\u003c\/strong\u003e, the mechanical room is just a corner of the basement shared by the water heater, the electrical panel and the washer. The ComboMax Ultra 50 takes the space of a conventional water heater: 60 in high and 22 in in diameter. Replacing a boiler and a water heater with a single appliance frees up room and simplifies maintenance.\u003c\/p\u003e\n\u003cp\u003eOn the electrical side, this size asks little: a 30 A breaker and Cu 10 or Al 10 wire at 240 V, according to the manufacturer. If the building is supplied at 208 V, Thermo 2000 states that output is multiplied by 0.75; we take that into account when choosing the size.\u003c\/p\u003e\n\u003cp\u003eThe T2 UltraSmart controller manages both functions. It gives priority to domestic hot water, sets its temperature and runs the heating pump when the thermostat calls for heat. The thermostatic mixing valve, pre-mounted at the factory, tempers the water sent to the taps.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eWe start with a free in-home estimate, in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e or elsewhere in Greater Montreal. We check the heating load, the existing system, the electrical panel and the location. You receive a written quote detailing the unit, the loop components and the work.\u003c\/p\u003e\n\u003cp\u003eOn installation day, the ComboMax Ultra is set in place, then connected by qualified personnel to the heating loop (1 in male NPT connections) and to domestic water (3\/4 in female NPT connections). Most accessories arrive already mounted: pressure regulator with check valve, mixing valve, automatic air vent, temperature and pressure gauge and hot water relief valve. After the electrical connection, the loop is filled and purged, the controller set and hot water output checked.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical).\u003c\/p\u003e\n\u003ch3\u003eThe warranty published by Thermo 2000\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer covers the tank and coils for 15 years in residential use, 10 years in commercial use, and electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLet’s talk about your project: free estimate, written quote and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available for your 4.5 kW ComboMax Ultra 50.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801451299108,"sku":"COMBOU50-4,5","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_COMBOMAX_ULTRA_50_4_5_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082265"},{"product_id":"chaudiere-electrique-avec-eau-chaude-integree-thermo-2000-combomax-ultra-70-4-5-kw-240v","title":"THERMO 2000 ComboMax Ultra 70 Electric Boiler with Integrated Hot Water | 4.5 kW - 240V","description":"\u003ch2\u003eLight heating and plenty of hot water: the 4.5 kW ComboMax Ultra 70\u003c\/h2\u003e\n\u003ch3\u003eDesigned for homes that use a lot of hot water\u003c\/h3\u003e\n\u003cp\u003eIn the morning, in a family, showers follow one another while the dishwasher finishes its cycle. That is the kind of home where Thermo 2000’s COMBOU70-4,5 stands out. It pairs a single 4.5 kW heating element with the large tank of the ComboMax Ultra series, which holds 71 US gal of heating water. According to the manufacturer, it delivers 73 US gal of hot water in 10 minutes and 95 US gal in one hour, for water delivered at 110 °F, cold water at 40 °F and boiler water at 180 °F.\u003c\/p\u003e\n\u003cp\u003eDrinking water, for its part, is never stored hot. It flows through parallel copper coils immersed in the heating water and heats up on the way. Thermo 2000 states that it arrives hot in under 7 seconds and that this design reduces the risk of Legionella.\u003c\/p\u003e\n\u003ch3\u003eOn the heating side: 4.5 kW for a home that needs little\u003c\/h3\u003e\n\u003cp\u003eThe unit delivers 15,354 BTU\/h at 240 V, on a single stage. It is a size for a recent or renovated, well-insulated home, or for a specific zone such as a basement heated by radiant floors. The T2 UltraSmart controller runs the heating pump when the thermostat calls and gives priority to domestic hot water when it is being drawn.\u003c\/p\u003e\n\u003cp\u003eThe electrical panel is lightly loaded: Thermo 2000 specifies a 30 A breaker and Cu 10 or Al 10 wire at 240 V. At 208 V, output is multiplied by 0.75 according to the manufacturer, which we check before recommending this size.\u003c\/p\u003e\n\u003ch3\u003eTaller than the 50: measure before choosing\u003c\/h3\u003e\n\u003cp\u003eThe large tank needs more room: 70 1\/2 in high, 24 in in diameter and 430 lb empty. In a basement in \u003cstrong\u003eMontreal\u003c\/strong\u003e or \u003cstrong\u003eLaval\u003c\/strong\u003e crossed by beams and ducts, the clearance matters, and we measure it during the visit. Heating connections are 1 1\/4 in male NPT, domestic water connections 3\/4 in female NPT.\u003c\/p\u003e\n\u003ch3\u003eAirGreen’s installation, from estimate to start-up\u003c\/h3\u003e\n\u003cp\u003eThe free estimate is done on site, in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and throughout Greater Montreal. We assess your hot water needs, the heating load, the panel and the location, then give you a written quote. On installation, the unit is set in place and connected by qualified personnel to the heating loop and to domestic water. The pressure regulator with check valve, the thermostatic mixing valve, the air vent and the temperature and pressure gauge are already factory-mounted, which shortens the work on site. We finish with filling, purging, setting the controller and a hot water test at a tap.\u003c\/p\u003e\n\u003cp\u003eA family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). Thermo 2000 covers the tank and coils for 15 years in residential use (10 years in commercial use) and electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate: written quote and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available for your ComboMax Ultra 70.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801453199652,"sku":"COMBOU70-4,5","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_COMBOMAX_ULTRA_70_4_5_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082265"},{"product_id":"chaudiere-electrique-thermo-2000-mini-bth-6-6-kw-240v","title":"THERMO 2000 Mini BTH 6 Electric Boiler | 6 kW - 240V","description":"\u003ch2\u003e6 kW of hot water heat for a garage, a basement or a small unit\u003c\/h2\u003e\n\u003ch3\u003eOne element, one zone, one wall\u003c\/h3\u003e\n\u003cp\u003eThermo 2000’s Mini BTH 6 rests on a simple idea: a single 6 kW element, controlled by an aquastat, in a cabinet that mounts on the wall. It delivers 20,472 BTU\/h at 240 V and holds only 1 US gal of water. The manufacturer describes it as very compact, multi-position and quiet, and intends it for condos and houses as well as basements and garages.\u003c\/p\u003e\n\u003ch3\u003ePractical uses around Montreal\u003c\/h3\u003e\n\u003cp\u003eA detached garage in \u003cstrong\u003eLaval\u003c\/strong\u003e whose concrete slab already contains radiant heating tubing. A unit fitted out in the basement of a \u003cstrong\u003eLongueuil\u003c\/strong\u003e home, with its own heated floor. A small house on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e heated by hydronic baseboards. In each case, the Mini BTH 6 heats an independent water loop without taking up floor space.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 also designs it as backup for a heat pump, a geothermal or a solar system. It runs with no GHG emissions and is easy to maintain, according to the manufacturer.\u003c\/p\u003e\n\u003ch3\u003eElectrical connection and control\u003c\/h3\u003e\n\u003cp\u003eAt 240 V, the appliance draws 25.0 A. Thermo 2000 specifies a 40 A breaker and Cu 8 or Al 6 wire. If the building is supplied at 208 V, output drops to 4.5 kW (21.8 A), which we take into account when choosing the size.\u003c\/p\u003e\n\u003cp\u003eThe aquastat sets the water temperature between 50 °F and 190 °F (10 °C and 90 °C). An indicator light shows when the element is heating, a switch turns the appliance off and a 24 V supply serves the thermostat and accessories. The Mini BTH has no outdoor sensor. On the water side, it accepts 4.1 US gpm at a 10 °F difference, or 2.0 US gpm at 20 °F, with negligible pressure drop according to the manufacturer. Two high temperature limits, automatic at 208 °F (98 °C) and manual at 227 °F (108 °C), protect the appliance.\u003c\/p\u003e\n\u003ch3\u003eOur installation\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate: heating needs of the space, condition of the circuit, electrical panel. The written quote then specifies the circulator and the expansion tank, which are not included with the boiler. On installation day, our technicians mount the appliance on the wall, connect its four 3\/4 in NPT connections to the circuit, install the supplied 30 psi relief valve and temperature and pressure gauge, make the electrical and thermostat connections, then fill, purge and check the heating with you.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Thermo 2000 warrants the tank for 15 years and the electrical and mechanical components for 2 years, in Canada and the United States.\u003c\/p\u003e\n\u003ch3\u003eGet your project started\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe install the Mini BTH in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Ask for your free estimate and your written quote; \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801453986084,"sku":"MINI BTH 6","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_MINI_BTH_6_KW_240V_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082264"},{"product_id":"chaudiere-electrique-conforto-at-at0623-6-kw-240v","title":"CONFORTO AT AT0623 Electric Boiler | 6 kW - 240V","description":"\u003ch2\u003eA compact, zero-emission 6 kW electric boiler for small hot-water loops\u003c\/h2\u003e\n\u003ch3\u003eWhat the AT0623 is and who it suits\u003c\/h3\u003e\n\u003cp\u003eThe Conforto AT0623 opens the AT series: it is a 6 kW, 240 V wall-mounted electric boiler, or 20,500 BTU\/h according to the manufacturer. It heats the water of a hydronic system with two 3,000 W elements that come on in two stages. When demand is low, a single element works; when the cold sets in, the second one joins it.\u003c\/p\u003e\n\u003cp\u003eThis size is meant for projects where the heating load stays modest. Think of a radiant floor in a finished basement, a room added at the back of the house, a workshop with a heated slab or a condo with hot-water radiators. Conforto presents the unit as a zero-emission solution, which makes it a consistent choice for a household that wants to heat its water with electricity.\u003c\/p\u003e\n\u003ch3\u003eHow it fits a Quebec home\u003c\/h3\u003e\n\u003cp\u003eThe AT0623 mounts on the wall, which keeps the mechanical room floor clear. It weighs about 70 lb (32 kg) as shipped and connects to the loop through 1 1\/4 in NPT fittings. Conforto designs it for low-temperature radiant heating as well as high-temperature hot-water baseboards and radiators.\u003c\/p\u003e\n\u003cp\u003eOn the electrical side, it needs a 240 V single-phase supply, with a minimum circuit ampacity of 38.8 A and maximum protection of 40 A. That is the lowest electrical demand in the AT series, an advantage when you add hot-water heating to only part of the house and the panel has little room left.\u003c\/p\u003e\n\u003cp\u003eThe controller brings two practical advantages. An immersion sensor at the heat exchanger outlet prevents short cycling, and a separate setpoint lets you make domestic hot water with an indirect water heater, with priority over space heating. A load-management input also lets the electricity provider control the unit.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eEverything starts with a free on-site estimate. We look at the existing loop or the radiant-floor project, your electrical panel’s capacity and the wall space available. You then receive a written quote that states the size chosen and the loop components to plan for, such as the circulator and the expansion tank.\u003c\/p\u003e\n\u003cp\u003eOn installation day, our technicians mount the boiler, connect it to the piping and the electrical circuit, fill and purge the system, then set the heating and domestic hot-water setpoints. We also explain the yearly maintenance, a condition of Conforto’s limited lifetime warranty.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01.\u003c\/p\u003e\n\u003ch3\u003ePlan your project\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe serve Montreal, Laval, Longueuil, the North Shore and the South Shore. Ask for your free estimate: you receive a clear written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available so you can go ahead without waiting.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Conforto","offers":[{"title":"Default Title","offer_id":67801455755556,"sku":"AT0623","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_CONFORTO_AT_AT0623_6_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-thermo-2000-mini-bth-ultra-6-6-kw-240v","title":"THERMO 2000 Mini BTH Ultra 6 Electric Boiler | 6 kW - 240V","description":"\u003ch2\u003eTwo 3 kW elements, two stages: a 6 kW boiler that measures out its heat\u003c\/h2\u003e\n\u003ch3\u003eWhat the Mini ULTRA 6 adds\u003c\/h3\u003e\n\u003cp\u003eIn Thermo 2000’s Mini ULTRA series, the 6 kW size marks a change. The smaller models have a single element; this one has two, 3 kW each, wired on two stages. The boiler therefore delivers its heat in two steps instead of one single 6 kW block. At full output, it produces 20,472 BTU\/h at 240 V, according to the manufacturer.\u003c\/p\u003e\n\u003cp\u003eThe rest of the unit keeps what defines the Mini ULTRA: a compact wall-mounted cabinet weighing 47 lb when shipped, 1 US gal of water, 3\/4 in NPT connections and the T2 UltraSmart controller with its outdoor sensor. The controller adjusts the water temperature to the weather with three curves (MIN, STD, MAX), shuts the heat off in mild weather and offers a Boost mode.\u003c\/p\u003e\n\u003ch3\u003eIn a condo, a bungalow or a plex\u003c\/h3\u003e\n\u003cp\u003eThis size suits small dwellings heated as a whole. A few typical cases:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea \u003cstrong\u003eMontreal\u003c\/strong\u003e condo heated by hydronic baseboards;\u003c\/li\u003e\n\u003cli\u003ea bungalow in \u003cstrong\u003eLaval\u003c\/strong\u003e or on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e with hot-water radiators;\u003c\/li\u003e\n\u003cli\u003ean old electric boiler to replace in the basement, on an existing loop;\u003c\/li\u003e\n\u003cli\u003ean air-to-water heat pump that needs electric back-up.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eEach situation calls for its own checks. The circuit must be a dedicated 240 V line, with a 40 A breaker and Cu 8 \/ Al 6 wire according to Thermo 2000; the boiler draws 25.0 A at full output. In a building supplied at 208 V, it delivers 4.5 kW at 21.8 A, which can change the size to choose. On the water side, the loop must provide 4.1 US gpm at a 10 °F ΔT or 2.0 US gpm at a 20 °F ΔT, and respect a maximum working pressure of 30 psi.\u003c\/p\u003e\n\u003ch3\u003eOur installation\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate, followed by a detailed written quote. Since Thermo 2000 does not supply the circulator and expansion tank, we include them in the quote, sized for your loop.\u003c\/p\u003e\n\u003cp\u003eOur technicians mount the boiler on the wall, connect it to the loop and install the supplied parts: 30 psi relief valve, drain valve and temperature and pressure gauge. They mount the outdoor sensor, make the electrical connection under AirGreen’s RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical), then fill and purge the system. Before leaving, we choose with you the preset that matches your radiators, baseboards or radiant floor.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years. We also install in \u003cstrong\u003eLongueuil\u003c\/strong\u003e and across the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 warrants the tank for 15 years and the electrical and mechanical components for 2 years (parts).\u003c\/p\u003e\n\u003ch3\u003eNext step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a description of your current system or ask for a free estimate: you will receive a written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available if you prefer to spread out your payments.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801456279844,"sku":"MINI BTH ULTRA 6","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_MINI_ULTRA_6_KW_240V_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082264"},{"product_id":"chaudiere-electrique-thermo-2000-mini-bth-7-5-7-5-kw-240v","title":"THERMO 2000 Mini BTH 7.5 Electric Boiler | 7.5 kW - 240V","description":"\u003ch2\u003eTwo elements, two stages: a 7.5 kW wall-mounted boiler that follows the home’s needs\u003c\/h2\u003e\n\u003ch3\u003eWhat sets the Mini BTH 7.5 apart\u003c\/h3\u003e\n\u003cp\u003eIn Thermo 2000’s Mini BTH series, the 7.5 kW size is the first to run on two stages. It combines two elements of different outputs, one of 3 kW and the other of 4.5 kW. The aquastats bring them on in stages according to demand, and an indicator light per element shows what is heating. In total, the boiler delivers 25,590 BTU\/h at 240 V, in a wall-mounted cabinet that holds only 1 US gal of water.\u003c\/p\u003e\n\u003cp\u003eLike every Mini BTH, it heats the water of radiant floors, radiators and hydronic baseboards, and Thermo 2000 also designs it as backup for a heat pump, a geothermal or a solar system. It runs quietly and with no GHG emissions, according to the manufacturer.\u003c\/p\u003e\n\u003ch3\u003eA typical South Shore bungalow\u003c\/h3\u003e\n\u003cp\u003eTake a bungalow on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e or in \u003cstrong\u003eLongueuil\u003c\/strong\u003e with a finished basement: radiant floor downstairs, hydronic baseboards upstairs, and an old electric boiler taking up space near the panel. The Mini BTH 7.5 mounts on the wall, frees the floor and needs only a 40 A breaker with Cu 8 or Al 6 wire, according to Thermo 2000. In mild weather, demand stays low and one stage may be enough; in deep cold, the second one comes on.\u003c\/p\u003e\n\u003ch3\u003eWhat to know before installing\u003c\/h3\u003e\n\u003cp\u003eIf your building is supplied at 208 V, output drops to 5.6 kW (27.2 A), which may tip the choice toward a larger size. The Mini BTH has no outdoor sensor: the water temperature is set on the aquastats, from 50 °F to 190 °F (10 °C to 90 °C). The circulator and expansion tank are not supplied. The manufacturer publishes a flow of 5.1 US gpm at a 10 °F difference, or 2.5 US gpm at 20 °F, with negligible pressure drop, which guides the choice of circulator. The maximum working pressure is 30 psi (207 kPa), and two high temperature limits protect the appliance, at 208 °F (98 °C) automatic and 227 °F (108 °C) manual.\u003c\/p\u003e\n\u003ch3\u003eAirGreen handles the installation\u003c\/h3\u003e\n\u003cp\u003eAfter a free on-site estimate, you receive a written quote that specifies the chosen size, the circulator and the expansion tank. Our technicians remove the old electric boiler, mount the Mini BTH on the wall, connect it to the circuit through its 3\/4 in NPT connections, install the supplied 30 psi relief valve and temperature and pressure gauge, make the electrical and thermostat connections, then fill, purge and check each zone with you.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Thermo 2000 warrants the tank for 15 years and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eAsk for your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe install the Mini BTH in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. The on-site estimate is free, the quote is in writing, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801457033508,"sku":"MINI BTH 7,5","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_MINI_BTH_7_5_KW_240V_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082264"},{"product_id":"chaudiere-electrique-thermo-2000-mini-bth-ultra-7-5-7-5-kw-240v","title":"THERMO 2000 Mini BTH Ultra 7.5 Electric Boiler | 7.5 kW - 240V","description":"\u003ch2\u003e7.5 kW on a 40 A circuit, to heat a whole dwelling with hot water\u003c\/h2\u003e\n\u003ch3\u003eA plex dwelling, a small house\u003c\/h3\u003e\n\u003cp\u003ePicture a duplex dwelling in \u003cstrong\u003eMontreal\u003c\/strong\u003e heated by hot-water radiators, or a small house in \u003cstrong\u003eLongueuil\u003c\/strong\u003e whose ground floor sits on a radiant floor. The original boiler is at the end of its life, the mechanical room is narrow, and you want to stay electric. Thermo 2000’s Mini ULTRA 7.5 fits this kind of project: a wall-mounted unit weighing 47 lb when shipped, holding 1 US gal of water and producing 25,590 BTU\/h at 240 V.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 designs it for radiant floors, radiators and hydronic baseboards, and also presents it as a back-up for an air-to-water heat pump or a geothermal system.\u003c\/p\u003e\n\u003ch3\u003eHow the Mini ULTRA 7.5 splits its output\u003c\/h3\u003e\n\u003cp\u003eThis size is the only one in the series that combines two elements of different output: one 3 kW and one 4.5 kW, wired on two stages. The T2 UltraSmart controller responds to thermostat demand and adjusts the water temperature to the supplied outdoor sensor, with a MIN, STD or MAX curve depending on your distribution system. In mild weather it stops heating; a Boost mode is provided for recovery.\u003c\/p\u003e\n\u003cp\u003eOn the electrical side, Thermo 2000 specifies a 40 A breaker and Cu 8 \/ Al 6 wire at 240 V. If your building is on 208 V, the output drops to 5.6 kW at 27.2 A, and we redo the calculation accordingly. The water temperature range is 50 °F to 190 °F, with two high limits: automatic at 208 °F and manual at 227 °F.\u003c\/p\u003e\n\u003ch3\u003eAirGreen’s installation, from the visit to start-up\u003c\/h3\u003e\n\u003cp\u003eWe first come to see your system for a free estimate. We note the radiators or floor area, the condition of the loop and the panel capacity, then give you a written quote. It includes the circulator and expansion tank, which are not supplied with the boiler.\u003c\/p\u003e\n\u003cp\u003eThe circulator is chosen to give the loop the flow Thermo 2000 requires: 5.1 US gpm at a 10 °F ΔT, or 2.5 US gpm at a 20 °F ΔT. The loop must also respect the 30 psi maximum working pressure. Our technicians mount the boiler, connect it through its 3\/4 in NPT connections, install the supplied relief valve, temperature and pressure gauge and drain valve, then mount the outdoor sensor. The electrical connection is made under our RBQ licence 5645-9605-01, which covers ventilation, refrigeration and electrical work. We finish with filling, purging and setting the controller.\u003c\/p\u003e\n\u003cp\u003eA family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, AirGreen also installs in \u003cstrong\u003eLaval\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. Thermo 2000 warrants the tank for 15 years and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eAsk for your quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTell us about your dwelling: the on-site estimate is free, the quote is in writing, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available to spread out your payments.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801462931748,"sku":"MINI BTH ULTRA 7,5","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_MINI_ULTRA_7_5_KW_240V_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082264"},{"product_id":"chaudiere-electrique-a-masse-thermique-thermo-2000-altsource-50-7-5-kw-240v","title":"THERMO 2000 AltSource 50 Thermal Mass Electric Boiler | 7.5 kW - 240V","description":"\u003ch2\u003eTwo stages, 7.5 kW and 48 US gal of water: a graduated electric backup for geothermal and air-to-water heat pumps\u003c\/h2\u003e\n\u003ch3\u003eA backup designed for renewable systems\u003c\/h3\u003e\n\u003cp\u003eA geothermal system or an air-to-water heat pump can carry most of a home’s heating. It still needs a backup, and that is the role Thermo 2000 gives the AltSource: a thermal mass electric boiler that serves as the backup source of a renewable-energy heating system. The manufacturer presents it as the only high water volume electric boiler on the market.\u003c\/p\u003e\n\u003cp\u003eThe AltSource 50-7.5 combines a 48 US gal tank with 7.5 kW of output at 240 V, or 25,590 BTU\/h according to Thermo 2000. The output is split between two elements, one of 3 kW and one of 4.5 kW, which come on in two stages. It is a mid-range size, designed for a mid-size house whose main source does most of the work.\u003c\/p\u003e\n\u003ch3\u003eThe controller does the fine work\u003c\/h3\u003e\n\u003cp\u003eThe T2 UltraSmart controller and its outdoor sensor are supplied. They set output and water temperature according to the outdoor temperature, shut heating off in warm weather and offer a Boost mode. The controller runs in standalone electric mode, the default setting, or in automatic transfer controlled by an external contact: we choose the mode based on how your main source is connected.\u003c\/p\u003e\n\u003ch3\u003eHow it fits a home in Laval or on the North Shore\u003c\/h3\u003e\n\u003cp\u003eTake a split-level house in \u003cstrong\u003eLaval\u003c\/strong\u003e or on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, heated by a radiant floor on two levels and an air-to-water heat pump. The AltSource 50-7.5 goes in the mechanical room: 22 in in diameter, 25 1\/2 in deep with the door, 56 7\/16 in high and 280 lb before filling. It connects to the loop through 1 in male NPT fittings and operates at a maximum pressure of 30 psi.\u003c\/p\u003e\n\u003cp\u003eThe electrical circuit calls for a 40 A breaker and Cu 8 \/ Al 6 wire gauge at 240 V, according to Thermo 2000. In a building with a 208 V supply, output becomes 5.6 kW (27.2 A). For the expansion tank, the manufacturer recommends a #30 with baseboards or a radiant floor, and a #60 with cast-iron radiators.\u003c\/p\u003e\n\u003ch3\u003eOur installation, step by step\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate: main source, hot-water loop, electrical panel and space.\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the unit, circulator, expansion tank and electrical work.\u003c\/li\u003e\n\u003cli\u003eSetting the unit in place, connecting it to the loop and mounting the outdoor sensor and supplied accessories.\u003c\/li\u003e\n\u003cli\u003eElectrical connection, filling, purging and controller setup, then a check with you.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Thermo 2000 covers the tank for 15 years in residential use and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eTake the next step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFrom Montreal to Longueuil, from Laval to the North Shore and the South Shore, ask for your free estimate. You receive a clear written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801467486500,"sku":"ALTSOURCE50-7,5","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_ALTSOURCE_50_7_5_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-a-masse-thermique-thermo-2000-altsource-70-7-5-kw-240v","title":"THERMO 2000 AltSource 70 Thermal Mass Electric Boiler | 7.5 kW - 240V","description":"\u003ch2\u003eA 7.5 kW electric backup that can also preheat your domestic water\u003c\/h2\u003e\n\u003ch3\u003eWhat the AltSource 70-7.5 does\u003c\/h3\u003e\n\u003cp\u003eThermo 2000’s AltSource is a thermal mass electric boiler designed to serve as the backup source of a renewable-energy heating system: air-to-water heat pump, geothermal or solar. The manufacturer describes it as the only high water volume electric boiler on the market. This model combines a 71 US gal tank with 7.5 kW at 240 V, or 25,590 BTU\/h, split between a 3 kW and a 4.5 kW element in two stages.\u003c\/p\u003e\n\u003cp\u003eIts T2 UltraSmart controller comes with an outdoor sensor. It modulates output and water temperature to the weather, shuts heating off in warm weather and offers a Boost mode. It runs in standalone electric mode by default or in automatic transfer controlled by an external contact.\u003c\/p\u003e\n\u003ch3\u003eAn option for domestic water\u003c\/h3\u003e\n\u003cp\u003eWhat sets the AltSource apart from a simple backup is the option Thermo 2000 provides for domestic water: a 26.2 sq ft parallel copper coil heat exchanger. It heats or preheats tap and shower water from the boiler. The manufacturer lists a maximum flow of 12 gpm, a maximum pressure of 125 psi and 3\/4 in male sweat domestic water connections (NSF 61).\u003c\/p\u003e\n\u003cp\u003eFor a family that uses a lot of hot water, the combination is attractive: a large reserve of heating water, two stages of output and a heat exchanger covered, like the tank, by Thermo 2000’s 15-year warranty in residential use. Electrical and mechanical components are covered for 2 years.\u003c\/p\u003e\n\u003ch3\u003eIn a Montreal duplex or a family home in Laval\u003c\/h3\u003e\n\u003cp\u003eIn a \u003cstrong\u003eMontreal\u003c\/strong\u003e duplex heated by radiators or a family home in \u003cstrong\u003eLaval\u003c\/strong\u003e with a radiant floor, the AltSource 70-7.5 goes in the mechanical room. It measures 24 in in diameter and 28 in deep with the door, and weighs 380 lb before filling. The heating loop connects in 1 1\/4 in NPT and operates at 30 psi maximum; Thermo 2000 recommends a #60 expansion tank with baseboards or a radiant floor, and a #90 with cast-iron radiators.\u003c\/p\u003e\n\u003cp\u003eThe electrical circuit calls for a 40 A breaker and Cu 8 \/ Al 6 wire gauge at 240 V. If the building has a 208 V supply, output becomes 5.6 kW (27.2 A).\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate, where we look at your main source, the heating loop, your hot-water needs and the electrical panel. The written quote specifies the unit, the domestic water option if you choose it, the circulator, the expansion tank and the electrical work. On the day, our technicians install and connect the boiler, mount the outdoor sensor, fill and purge the system, then set the controller with you.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01.\u003c\/p\u003e\n\u003ch3\u003eLet’s talk about your project\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe serve Montreal, Laval, Longueuil, the North Shore and the South Shore. Ask for your free estimate and receive a written quote; \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801469190436,"sku":"ALTSOURCE70-7,5","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_ALTSOURCE_70_7_5_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-avec-eau-chaude-integree-thermo-2000-combomax-ultra-50-7-5-kw-240v","title":"THERMO 2000 ComboMax Ultra 50 Electric Boiler with Integrated Hot Water | 7.5 kW - 240V","description":"\u003ch2\u003eTwo heating stages and all the home’s hot water, in a 48 US gal tank\u003c\/h2\u003e\n\u003ch3\u003eA boiler that does not always run flat out\u003c\/h3\u003e\n\u003cp\u003eIn October, a house does not need the same heat as in January. Thermo 2000’s 7.5 kW ComboMax Ultra 50 meets that reality with two elements of different ratings, 3 kW and 4.5 kW, on two stages. Heat is added step by step, up to 25,590 BTU\/h at 240 V, instead of switching on full output at once.\u003c\/p\u003e\n\u003cp\u003eThe same appliance makes domestic hot water. Parallel copper coils sit in the 48 US gal of heating water in the tank; drinking water flows through them and heats up on the way, without being stored. Thermo 2000 publishes 53 US gal of hot water in 10 minutes and 90 US gal in one hour, for water delivered at 110 °F, cold water at 40 °F and boiler water at 180 °F.\u003c\/p\u003e\n\u003ch3\u003eThe homes it suits\u003c\/h3\u003e\n\u003cp\u003eThis size is aimed at bungalows and small two-storey houses heated by hot-water baseboards, radiators or radiant floors, in \u003cstrong\u003eLaval\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and in \u003cstrong\u003eMontreal\u003c\/strong\u003e. It is above all for owners who want a single appliance to maintain for heating and hot water. The tank takes the space of a conventional water heater, 60 in high and 22 in in diameter, and the unit weighs 325 lb empty.\u003c\/p\u003e\n\u003cp\u003eThe T2 UltraSmart controller, with its backlit display, manages domestic hot water temperature, gives it priority and runs the heating pump when the thermostat calls. The thermostatic mixing valve, already mounted, tempers the water sent to the taps. Thermo 2000 announces an expected service life of more than 30 years and minimal maintenance.\u003c\/p\u003e\n\u003cp\u003eElectrically, plan a 240 V single-phase circuit with a 40 A breaker and Cu 8 or Al 6 wire. In a building supplied at 208 V, the manufacturer states that output is multiplied by 0.75.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eA free in-home estimate, in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and throughout Greater Montreal: heating load, hot water needs, electrical panel and location.\u003c\/li\u003e\n\u003cli\u003eA written quote specifying the unit, the loop components and each step of the work.\u003c\/li\u003e\n\u003cli\u003eSetting the unit in place and connecting it, by qualified personnel, to the heating loop (1 in male NPT) and to domestic water (3\/4 in female NPT).\u003c\/li\u003e\n\u003cli\u003eThe electrical connection, filling and purging the loop, setting the controller and a full test of heating and hot water.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). Thermo 2000’s warranty covers the tank and coils for 15 years in residential use (10 years in commercial use) and electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eNext step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBook your free estimate: we give you a written quote for the 7.5 kW ComboMax Ultra 50, with \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e options.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801473450276,"sku":"COMBOU50-7,5","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_COMBOMAX_ULTRA_50_7_5_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082265"},{"product_id":"chaudiere-electrique-avec-eau-chaude-integree-thermo-2000-combomax-ultra-70-7-5-kw-240v","title":"THERMO 2000 ComboMax Ultra 70 Electric Boiler with Integrated Hot Water | 7.5 kW - 240V","description":"\u003ch2\u003e113 US gal of hot water in one hour and 7.5 kW of heating, in a single appliance\u003c\/h2\u003e\n\u003ch3\u003eTwo bathrooms, one heat source\u003c\/h3\u003e\n\u003cp\u003eWhen a home has two bathrooms, hot water goes fast: a shower upstairs, a bath on the ground floor, the washer at the same time. Thermo 2000’s 7.5 kW ComboMax Ultra 70 was designed for that pace. According to the manufacturer, it delivers 76 US gal of hot water in 10 minutes and 113 US gal in one hour, for water at 110 °F, cold water at 40 °F and boiler water at 180 °F. It also heats the whole house through the hot-water loop: radiators, hydronic baseboards or radiant floors.\u003c\/p\u003e\n\u003ch3\u003eWhat happens inside the tank\u003c\/h3\u003e\n\u003cp\u003eThe tank holds 71 US gal of heating water. Two elements, 3 kW and 4.5 kW, heat it on two stages, up to 25,590 BTU\/h at 240 V. Parallel copper coils sit in that body of water: drinking water flows through them and heats up on the way. So no domestic hot water is stored. Thermo 2000 states that it arrives hot in under 7 seconds and that this design reduces the risk of Legionella.\u003c\/p\u003e\n\u003cp\u003eThe T2 UltraSmart controller arbitrates between the two uses. It gives priority to domestic hot water, manages its temperature and runs the heating pump when the thermostat calls. At the outlet, the pre-mounted thermostatic mixing valve delivers a steady temperature to the taps.\u003c\/p\u003e\n\u003ch3\u003eBefore choosing: height, weight and panel\u003c\/h3\u003e\n\u003cp\u003eThe 70 model is 70 1\/2 in high and 24 in in diameter, and weighs 430 lb empty. In a semi-detached house in \u003cstrong\u003eLaval\u003c\/strong\u003e or a two-storey home on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, the basement stairs and the clearance under the beams often decide the location; we check them on site. Electrically, a 240 V single-phase circuit with a 40 A breaker and Cu 8 or Al 6 wire is needed. At 208 V, output is multiplied by 0.75 according to the manufacturer. Connections are 1 1\/4 in male NPT for heating and 3\/4 in female NPT for domestic water.\u003c\/p\u003e\n\u003ch3\u003eHow we install\u003c\/h3\u003e\n\u003cp\u003eWe start with a free estimate at your home, in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e or elsewhere in Greater Montreal. We talk about your hot water habits, measure the space, check the panel and the heating system. The written quote that follows specifies the unit, the loop components and the work.\u003c\/p\u003e\n\u003cp\u003eOn installation, the unit is set in place, then connected by qualified personnel to the heating loop and to domestic water. The accessories supplied by Thermo 2000 (pressure regulator with check valve, automatic air vent, temperature and pressure gauge, 30 psi and 125 psi relief valves) are largely already mounted. After the electrical connection, we fill and purge the loop, set the controller and test hot water at several taps.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). Thermo 2000 covers the tank and coils for 15 years in residential use (10 years in commercial use) and electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate and written quote: \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available for the 7.5 kW ComboMax Ultra 70.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801477447972,"sku":"COMBOU70-7,5","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_COMBOMAX_ULTRA_70_7_5_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082265"},{"product_id":"ventilo-convecteur-hydronique-thermo-2000-ventum-40","title":"THERMO 2000 VenTum 40 Hydronic Fan Coil","description":"\u003ch2\u003eHot water in the loop, warm air in the ducts\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eThermo 2000 VenTum 40 hydronic fan coil\u003c\/strong\u003e links a hot-water heating system to a duct network. It takes hot water from a closed loop, circulates it through a 4-row copper coil and blows the heated air into the house, up to 1,100 CFM. The 1\/2 HP ECM fan, the built-in 3-speed circulator and the digital controller are housed in the same cabinet.\u003c\/p\u003e\n\u003ch3\u003eWho the VenTum 40 is for\u003c\/h3\u003e\n\u003cp\u003eIt suits homes that already have ductwork and that heat, or want to heat, with an electric boiler or an air-to-water heat pump. You keep forced-air distribution, but the heat comes from water. The front controller displays the unit’s status, temperatures and alarm codes. It manages 2 zones, offers separate airflow settings for heating, cooling, ventilation and dehumidification, a BOOST mode and an anti-freeze function that takes over if the house thermostat fails.\u003c\/p\u003e\n\u003ch3\u003eReading the capacity table for your source\u003c\/h3\u003e\n\u003cp\u003eThe heat delivered depends mainly on the water temperature. Thermo 2000 publishes a full table, with return air at 70 °F (21 °C). At 3 GPM and between 700 and 1,100 CFM, the VenTum 40 delivers 13,400 to 17,500 BTU\/h with 100 °F water, 24,400 to 31,900 BTU\/h at 120 °F and 47,400 to 63,200 BTU\/h at 160 °F. An air-to-water heat pump often works at the low end of this table, while an electric boiler can aim higher. That is why we size the unit with your source’s actual water temperature, not with the highest figure on the sheet.\u003c\/p\u003e\n\u003cp\u003eFor summer, an air conditioner or heat pump coil can be added as an option, with an outdoor unit. The manufacturer associates 2 tons of cooling with 700 and 800 CFM, and 3 tons with 900, 1,000 and 1,100 CFM.\u003c\/p\u003e\n\u003ch3\u003eIts place in a Quebec home\u003c\/h3\u003e\n\u003cp\u003eThe VenTum is multi-position: vertical in a basement in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, horizontal when height is limited in a townhouse in \u003cstrong\u003eMontreal\u003c\/strong\u003e. The return opening is pre-cut on the right, left or bottom, which simplifies the connection to existing ductwork. It weighs 99 lb, connects to the water through soldered 3\/4 in copper fittings and runs on 120 V single phase. The ductwork must stay within a maximum external static pressure of 0.75 in. w.c. The 16 x 20 x 1 in filter slides into the supplied rack.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation includes\u003c\/h3\u003e\n\u003cp\u003eWe install the VenTum with electric boilers and air-to-water heat pumps, in \u003cstrong\u003eLaval\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and throughout Greater Montreal: free on-site estimate, written quote, setting the unit, connecting it to the water loop and the ductwork, placing the supplied air temperature sensors, adjusting the airflow and commissioning. The thermostat is not included; we choose it with you. Sold alone, the unit does not qualify for the LogisVert grant.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than 15 years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). Thermo 2000 warrants all VenTum parts and components for 2 years, under its terms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTell us which source supplies your loop and at what temperature: we check whether the VenTum 40 is enough for the house. Free estimate and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801478594852,"sku":"VENTUM40","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/VENTILO_CONVECTEUR_HYDRONIQUE_THERMO_2000_VENTUM_40_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082279"},{"product_id":"chaudiere-electrique-conforto-at-at0824-8-kw-240v","title":"CONFORTO AT AT0824 Electric Boiler | 8 kW - 240V","description":"\u003ch2\u003eAn 8 kW wall-mounted electric boiler to heat a dwelling with hot water\u003c\/h2\u003e\n\u003ch3\u003eWho it suits: dwellings and small houses heated with hot water\u003c\/h3\u003e\n\u003cp\u003eHot-water radiators are still part of many homes in \u003cstrong\u003eMontreal\u003c\/strong\u003e and \u003cstrong\u003eLongueuil\u003c\/strong\u003e. When the old electric boiler reaches the end of its life, the Conforto AT0824 offers a straightforward replacement: 8 kW at 240 V, or 27,300 BTU\/h according to the manufacturer, in a cabinet that mounts on the wall.\u003c\/p\u003e\n\u003cp\u003eIt also suits smaller new projects: a bungalow getting a radiant floor in the basement, a condo with radiators, an addition tied into an existing loop. Conforto designs it for low-temperature radiant heating as well as high-temperature hot-water baseboards.\u003c\/p\u003e\n\u003ch3\u003eWhat it changes day to day\u003c\/h3\u003e\n\u003cp\u003eThe AT0824 heats with two 4,000 W elements, in two stages. In mild weather, a single element is often enough; the boiler adds the second when the loop calls for more. It also alternates which element starts first, so the two take turns.\u003c\/p\u003e\n\u003cp\u003eAn immersion sensor at the heat exchanger outlet controls the stages and prevents short cycling. If you add an indirect water heater, the controller manages a separate domestic hot-water setpoint and gives it priority: the shower comes before room heating while the tank gets back to temperature. A load-management input also lets the electricity provider control the unit.\u003c\/p\u003e\n\u003ch3\u003eHow it fits your home\u003c\/h3\u003e\n\u003cp\u003eElectrically, the AT0824 needs a dedicated 240 V single-phase circuit, with a minimum ampacity of 49.2 A and maximum protection of 50 A. On the water side, it connects with 1 1\/4 in NPT fittings and requires a minimum flow of 2.7 gpm (for a 20 °F ΔT). It weighs about 70 lb (32 kg) as shipped. The 30 psi relief valve and the temperature and pressure gauge are included.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate: condition of the loop, existing electrical circuit, wall location, and whether there is an indirect water heater. The written quote that follows states the boiler chosen and the loop components to add or replace.\u003c\/p\u003e\n\u003cp\u003eFor a replacement, our technicians drain the system, remove the old boiler, mount the AT0824, connect it to the piping and the panel, then fill, purge and commission it. We set the setpoints with you and remind you of the yearly maintenance required by Conforto’s limited lifetime warranty. AirGreen is a \u003cstrong\u003eMontreal\u003c\/strong\u003e family business in operation for more than fifteen years, holding RBQ licence 5645-9605-01.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAre you in Montreal, Laval, Longueuil, on the North Shore or the South Shore? Ask for your free estimate and your written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Conforto","offers":[{"title":"Default Title","offer_id":67801483804964,"sku":"AT0824","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_CONFORTO_AT_AT0824_8_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"aerotherme-a-eau-chaude-sterling-hsb01811-montreal-laval-longueuil-rive-sud-rive-nord","title":"STERLING HSB01811 Hot-Water Unit Heater | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eA compact heat boost, hung from the ceiling and fed by your hot-water loop\u003c\/h2\u003e\n\u003ch3\u003eThe smallest unit heater in Sterling’s HS series\u003c\/h3\u003e\n\u003cp\u003eThe Sterling HSB01811 is a horizontal hot-water unit heater: a coil carrying the water from your heating system, and a propeller fan that pushes air through that coil and into the room. It is the smallest size in the HS series. With 200°F entering water and 60°F entering air, the manufacturer publishes 13,050 BTU\/h at an airflow of 395 CFM.\u003c\/p\u003e\n\u003cp\u003eIt is aimed mainly at building owners and store managers who already have a hot-water loop and want to heat a small, demanding space: an entrance vestibule where the door opens all day, a technical room, a small attached shed. Because it hangs from the ceiling, it takes no floor space and stays out of the way of boxes, carts and wet boots.\u003c\/p\u003e\n\u003ch3\u003eHow it fits a water-heated building in Quebec\u003c\/h3\u003e\n\u003cp\u003eAt AirGreen, we install these unit heaters on electric boilers and air-to-water heat pumps. One point matters more than anything else: water temperature. The 13,050 BTU\/h are measured at 200°F. If your equipment supplies cooler water, output drops according to the factors Sterling publishes: 0.857 at 180°F, 0.571 at 140°F, 0.429 at 120°F. So we always start from the actual supply temperature of your boiler or heat pump, not from the model number, to choose the size.\u003c\/p\u003e\n\u003cp\u003eOn the water side, the HSB01811 needs 1.3 GPM with a 20°F drop, for a pressure drop of only 0.005 ft H2O. These values let us check whether the existing circulator is enough. If the loop contains propylene glycol, for example to protect a room that could freeze, Sterling also publishes correction factors, which we apply to the calculation.\u003c\/p\u003e\n\u003cp\u003eThe 16 W motor runs on 115 V, single phase, 60 Hz. According to the manufacturer, it is totally enclosed with thermal overload protection.\u003c\/p\u003e\n\u003ch3\u003eWhat our installation covers\u003c\/h3\u003e\n\u003cp\u003eIt all starts with a site visit: we measure the space, note the available water temperature and locate the structure that will carry the unit. Then our technicians:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ehang the unit heater by rods from the connections provided, level, as the manufacturer requires;\u003c\/li\u003e\n\u003cli\u003econnect it to your hot-water loop, with isolation valves and air purging;\u003c\/li\u003e\n\u003cli\u003emake the 115 V electrical connection and wire the control chosen with you;\u003c\/li\u003e\n\u003cli\u003estart up the unit and check the water flow and temperature drop.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). We serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet’s talk about your space\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFor a vestibule, a technical room or a small shed, ask us for a free on-site estimate. You receive a written quote stating the size selected and the water temperature used for the calculation, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Sterling","offers":[{"title":"Default Title","offer_id":67801486491940,"sku":"HSB01811","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/AEROTHERME_A_EAU_CHAUDE_STERLING_HSB_01811_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082220"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr600180p3-180-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR600180P3 Commercial Electric Boiler | 180 kW - 600V 3 Phase","description":"\u003ch2\u003e614,160 BTU\/h on 600 V to heat a large building with hot water\u003c\/h2\u003e\n\u003ch3\u003eA commercial boiler that adapts to the emitters\u003c\/h3\u003e\n\u003cp\u003eThe VoltMax SCR 180 is Thermo 2000’s 180 kW commercial electric boiler, here in its 600 V three-phase version. It delivers 614,160 BTU\/h according to the manufacturer and modulates its output from 0 to 100% through solid-state relays (SCR), alongside relay stages. Its setpoint adjusts from 50 °F to 200 °F (10 °C to 93 °C): high enough for a radiator system, low enough for a radiant floor.\u003c\/p\u003e\n\u003cp\u003eIt is meant for owners and managers of large residential, commercial or mixed-use buildings, engineers preparing a replacement and contractors modernizing a mechanical room. Hydro-air coils and an indirect water heater, served by a second setpoint, are also among its possible uses.\u003c\/p\u003e\n\u003ch3\u003eIn Quebec’s large buildings\u003c\/h3\u003e\n\u003cp\u003eTake a mixed-use building in \u003cstrong\u003eMontreal\u003c\/strong\u003e, with shops on the ground floor and offices upstairs, heated by an old radiator system. On 600 V three-phase, the VoltMax SCR 180 draws 173.2 A there. The supplied outdoor sensor lets the controller lower the water temperature in mild weather and raise it when it is cold, and schedules turn heating down when the premises are closed.\u003c\/p\u003e\n\u003cp\u003eIn a newer building in \u003cstrong\u003eLaval\u003c\/strong\u003e with a radiant floor, the same boiler runs at low temperature, still guided by the outdoor sensor. In both cases it stays compact: vertical, with 3 in of clearance on the sides and back, 24 in in front and 32 in above. It holds 30 US gal of water and weighs 550 lb (250 kg). The Schneider Electric controller displays in French or English, communicates over BACnet IP and MS-TP and sends its alarms by email.\u003c\/p\u003e\n\u003ch3\u003eOur work, from estimate to commissioning\u003c\/h3\u003e\n\u003cp\u003eThe on-site estimate is free. We check the 600 V service, the condition of the system and the emitters, and the access to the mechanical room. The written quote that follows specifies the boiler, the circulating pump and the expansion tank, which Thermo 2000 does not count among the supplied items.\u003c\/p\u003e\n\u003cp\u003eOur crews set the boiler in place, connect the system and the electrical circuit, fill and purge the loop, then set the setpoint, the outdoor reset curve and the schedules. The manufacturer, for its part, warrants the tank for 10 years, as a limited warranty for closed-loop heating, and the electrical and mechanical components for 2 years. A family business from \u003cstrong\u003eMontreal\u003c\/strong\u003e established for more than fifteen years, AirGreen works under RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical).\u003c\/p\u003e\n\u003ch3\u003eYour building, our quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn Montreal, Laval, Longueuil, on the North Shore or the South Shore, have your building assessed for free. You will receive a written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801486852388,"sku":"VOLTSCR600180P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR600180P3_180_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-thermo-2000-mini-bth-9-9-kw-240v","title":"THERMO 2000 Mini BTH 9 Electric Boiler | 9 kW - 240V","description":"\u003ch2\u003e9 kW on the wall to heat an entire unit with hot water\u003c\/h2\u003e\n\u003ch3\u003eMontreal plexes and condos\u003c\/h3\u003e\n\u003cp\u003eIn many \u003cstrong\u003eMontreal\u003c\/strong\u003e plexes and \u003cstrong\u003eLaval\u003c\/strong\u003e condos, each unit has its own hot water heating: radiators, hydronic baseboards, sometimes a radiant floor. When the old floor-standing electric boiler reaches the end of its life, replacing it with a wall-mounted appliance frees up space in a storage room or laundry room that is already tight. Thermo 2000’s Mini BTH 9 was designed for this kind of unit.\u003c\/p\u003e\n\u003ch3\u003eThe size for whole units\u003c\/h3\u003e\n\u003cp\u003eWith 9 kW, or 30,708 BTU\/h at 240 V, the Mini BTH 9 goes beyond a simple backup zone and can heat an entire unit, depending on its heat loss. It runs on two identical 4.5 kW elements spread over two stages: the aquastats bring them on according to demand and an indicator light per element shows what is heating. Its cabinet holds only 1 US gal of water and mounts on the wall, in several positions.\u003c\/p\u003e\n\u003cp\u003eWater can be set from 50 °F to 190 °F (10 °C to 90 °C). That range covers radiators, which need hot water, as well as radiant floors, which work at a lower temperature. On flow, Thermo 2000 publishes 6.1 US gpm at a 10 °F difference, or 3.0 US gpm at 20 °F, with negligible pressure drop. The manufacturer also presents it as backup for a heat pump, a geothermal or a solar system.\u003c\/p\u003e\n\u003ch3\u003eElectrical, control and safety\u003c\/h3\u003e\n\u003cp\u003eAt 240 V, the appliance draws 37.5 A; Thermo 2000 specifies a 50 A breaker and Cu 8 or Al 6 wire. Many apartment buildings are supplied at 208 V: in that case, the boiler gives 6.7 kW (32.6 A), and we take that into account when choosing the size. The Mini BTH has no outdoor sensor. A switch turns the appliance off, a 24 V supply serves the thermostat, and two high temperature limits, automatic at 208 °F (98 °C) and manual at 227 °F (108 °C), protect the boiler. The maximum working pressure is 30 psi (207 kPa).\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate, then you receive a written quote that includes the circulator and the expansion tank, which are not included with the boiler. Our technicians remove the old electric boiler, mount the Mini BTH, connect its four 3\/4 in NPT connections to the existing system, install the supplied 30 psi relief valve and temperature and pressure gauge, then make the electrical and thermostat connections. They fill, bleed the air from the radiators or baseboards and check the heating with you.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Thermo 2000 warrants the tank for 15 years and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003ch3\u003eReplace your boiler\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe install the Mini BTH in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Ask for your free estimate: the quote is in writing and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801489539364,"sku":"MINI BTH 9","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_MINI_BTH_9_KW_240V_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082264"},{"product_id":"ventilo-convecteur-hydronique-thermo-2000-ventum-60","title":"THERMO 2000 VenTum 60 Hydronic Fan Coil","description":"\u003ch2\u003eUp to 2,000 CFM of water-heated air, with optional cooling\u003c\/h2\u003e\n\u003cp\u003eIn a large house that already has ductwork, switching to hot-water heating does not mean giving up forced air. The \u003cstrong\u003eThermo 2000 VenTum 60 hydronic fan coil\u003c\/strong\u003e takes hot water from an electric boiler or an air-to-water heat pump and turns it into warm air, up to 2,000 CFM. It is the large size in the VenTum series: 3\/4 HP ECM fan, 10 x 10 in wheel, 4-row copper coil measuring 15 x 22 x 3.5 in and built-in 3-speed circulator.\u003c\/p\u003e\n\u003ch3\u003eThe large size in the VenTum series\u003c\/h3\u003e\n\u003cp\u003eThe VenTum 60 is meant for good-sized houses, multi-storey homes in \u003cstrong\u003eLaval\u003c\/strong\u003e or on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, and offices or small shops that already have ductwork. Its front digital controller manages 2 zones, displays status, temperatures and alarm codes, and allows a separate airflow for each mode: heating, cooling, ventilation, dehumidification. Airflow is set in 10 CFM steps, and a BOOST mode is available. An anti-freeze function takes over if the house thermostat fails.\u003c\/p\u003e\n\u003cp\u003eIn summer, an air conditioner or heat pump coil can be added as an option, with an outdoor unit. Thermo 2000 associates 3 tons of cooling with 1,200 CFM, 4 tons with 1,400 and 1,600 CFM, and 5 tons with 1,800 and 2,000 CFM.\u003c\/p\u003e\n\u003ch3\u003eChoosing the right operating point\u003c\/h3\u003e\n\u003cp\u003eThe heat delivered depends on the water temperature and its flow. The manufacturer publishes its capacities with return air at 70 °F (21 °C). With 120 °F water, the VenTum 60 delivers 35,900 to 47,400 BTU\/h at 3 GPM, and 40,000 to 56,000 BTU\/h at 5 GPM, between 1,200 and 2,000 CFM. With 140 °F water at 5 GPM, the range rises to 59,100 to 87,500 BTU\/h. The published pressure drop is 5 psi at 5 GPM. We therefore start from your source’s actual temperature to choose the water flow and the airflow, then check that the ductwork stays within the maximum external static pressure of 0.75 in. w.c.\u003c\/p\u003e\n\u003cp\u003eThe loop can hold water or a propylene glycol mix up to 50%, with water from 50 to 200 °F. The water connections are 3\/4 in copper, soldered.\u003c\/p\u003e\n\u003ch3\u003eInstallation and next steps\u003c\/h3\u003e\n\u003cp\u003eAirGreen installs the VenTum in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and throughout Greater Montreal, with electric boilers and air-to-water heat pumps. Our work includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe free on-site estimate and a written quote;\u003c\/li\u003e\n\u003cli\u003esetting the unit, vertical or horizontal depending on the space, with the pre-cut return on the side that works;\u003c\/li\u003e\n\u003cli\u003econnecting it to the water loop and the ductwork, and placing the supplied air temperature sensors;\u003c\/li\u003e\n\u003cli\u003esetting the airflow for each mode and commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe unit weighs 120 lb and runs on 120 V single phase. The thermostat is not included. Sold alone, the VenTum 60 does not qualify for the LogisVert grant. AirGreen is a family business established in Montreal for more than 15 years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). Thermo 2000 warrants all VenTum parts and components for 2 years, under its terms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSend us the area to serve, your heat source and your cooling plans: we confirm whether the VenTum 60 is the right size. Free estimate and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801489670436,"sku":"VENTUM60","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/VENTILO_CONVECTEUR_HYDRONIQUE_THERMO_2000_VENTUM_60_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082278"},{"product_id":"aerotherme-a-eau-chaude-sterling-hsb02411-montreal-laval-longueuil-rive-sud-rive-nord","title":"STERLING HSB02411 Hot-Water Unit Heater | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eWarm air above the car, without losing an inch of floor\u003c\/h2\u003e\n\u003ch3\u003eA hot-water unit heater for the attached garage\u003c\/h3\u003e\n\u003cp\u003eIn many houses heated by an electric boiler, the attached garage is the poor relation: a baseboard added in a hurry, or nothing at all. The Sterling HSB02411 offers another approach. This horizontal unit heater connects to the same hot-water loop as the house and hangs from the ceiling, above the parking space. The coil releases the water’s heat, and the propeller fan spreads it through the room.\u003c\/p\u003e\n\u003cp\u003eSterling rates it at 17,400 BTU\/h with 200°F entering water and 60°F entering air, for an airflow of 450 CFM and an outlet velocity of 450 FPM. It also suits a hobby workshop, an insulated shed or a small business’s storage room, as long as a hot-water loop runs nearby.\u003c\/p\u003e\n\u003ch3\u003eWhat to know for a Quebec house\u003c\/h3\u003e\n\u003cp\u003eBefore the BTU count, we look at the water temperature. Your electric boiler or air-to-water heat pump may run below the 200°F of the manufacturer’s rating, and the unit heater then delivers less heat. Sterling publishes the factors to apply: 0.715 at 160°F, 0.571 at 140°F, 0.429 at 120°F. The size is therefore chosen with the actual supply temperature, and with a heat-loss calculation for the garage.\u003c\/p\u003e\n\u003cp\u003eA garage also raises the question of freezing. If the heat can be shut off there, the loop can contain propylene glycol; the manufacturer publishes correction factors for that mix, and we take them into account. On the circulation side, the unit needs 1.8 GPM with a 20°F drop, for a pressure drop of 0.014 ft H2O.\u003c\/p\u003e\n\u003cp\u003eThe electrical connection stays simple: 115 V, single phase, 60 Hz. The 16 W motor is single speed, totally enclosed with thermal overload protection, according to Sterling.\u003c\/p\u003e\n\u003ch3\u003eOur installation, step by step\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eGarage visit, heat-loss calculation and reading of the available water temperature.\u003c\/li\u003e\n\u003cli\u003eChoice of a clear location, taking the garage door and the free height into account.\u003c\/li\u003e\n\u003cli\u003eHanging by rods from the connections provided on the unit, level.\u003c\/li\u003e\n\u003cli\u003eConnection to the house’s hot-water loop, with isolation valves and air purging.\u003c\/li\u003e\n\u003cli\u003e115 V electrical connection and installation of the control chosen with you.\u003c\/li\u003e\n\u003cli\u003eStart-up and check of the water flow.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eA family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). Our crews travel to \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eYour garage, heated from the house\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free on-site estimate: we check your boiler, your loop and your garage, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Sterling","offers":[{"title":"Default Title","offer_id":67801492422948,"sku":"HSB02411","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/AEROTHERME_A_EAU_CHAUDE_STERLING_HSB_02411_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082219"},{"product_id":"chaudiere-electrique-thermo-2000-mini-bth-ultra-9-9-kw-240v","title":"THERMO 2000 Mini BTH Ultra 9 Electric Boiler | 9 kW - 240V","description":"\u003ch2\u003e9 kW on the wall: a small house heated with hot water, without losing floor space\u003c\/h2\u003e\n\u003ch3\u003eA 9 kW boiler in a 47 lb unit\u003c\/h3\u003e\n\u003cp\u003eThermo 2000’s Mini ULTRA 9 keeps the series’ compact format, with 1 US gal of water and 47 lb when shipped, but fits two 4.5 kW elements wired on two stages. The result: 9 kW, or 30,708 BTU\/h at 240 V according to the manufacturer, enough to feed the radiators, hydronic baseboards or radiant floor of a small house.\u003c\/p\u003e\n\u003cp\u003eIt is meant for homeowners who want all-electric hot-water heating, with no GHG emissions on site, in a mechanical room where space is tight. The flexible connections and multi-position mounting Thermo 2000 provides make wall installation easier, next to the water heater or the electrical panel. The manufacturer also presents it as a back-up for a geothermal or solar system.\u003c\/p\u003e\n\u003ch3\u003eWhat to check in a Quebec house\u003c\/h3\u003e\n\u003cp\u003eA 9 kW boiler needs a serious circuit. Thermo 2000 specifies a 50 A breaker and Cu 8 \/ Al 6 wire at 240 V; the unit draws 37.5 A at full output. In a house that already has an electric range, dryer and water heater, the panel must be able to take this load. If the supply is 208 V, the output becomes 6.7 kW (32.6 A): a detail that sometimes changes the size to choose.\u003c\/p\u003e\n\u003cp\u003eThe water loop matters just as much. It must provide 6.1 US gpm at a 10 °F ΔT, or 3.0 US gpm at a 20 °F ΔT, and stay within the 30 psi maximum working pressure. The T2 UltraSmart controller handles the rest: it reads the supplied outdoor sensor, sets the water temperature along a MIN, STD or MAX curve, and shuts the heat off in mild weather. Whether you live in \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e or on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, these checks are part of our visit.\u003c\/p\u003e\n\u003ch3\u003eWhat we do on installation day\u003c\/h3\u003e\n\u003cp\u003eBefore the work, you receive a written quote, prepared after a free on-site estimate. It includes the circulator and expansion tank, which are not supplied with the boiler. On the day, our technicians:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emount the boiler on the wall and connect it to the loop through its 3\/4 in female NPT connections;\u003c\/li\u003e\n\u003cli\u003einstall the supplied 30 psi relief valve, temperature and pressure gauge and drain valve;\u003c\/li\u003e\n\u003cli\u003emount the outdoor sensor and make the electrical connection, under AirGreen’s RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical);\u003c\/li\u003e\n\u003cli\u003efill, purge and set the controller for your distribution system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, and we also serve the whole \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. Thermo 2000 warrants the tank for 15 years and the electrical and mechanical components for 2 years (parts).\u003c\/p\u003e\n\u003ch3\u003eOn to your quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm that 9 kW suits your house, you receive a written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available to spread out your payments.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801495404836,"sku":"MINI BTH ULTRA 9","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_MINI_ULTRA_9_KW_240V_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082264"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr600165p3-165-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR600165P3 Commercial Electric Boiler | 165 kW - 600V 3 Phase","description":"\u003ch2\u003e165 kW on 600 V to heat the building and its domestic hot water\u003c\/h2\u003e\n\u003ch3\u003eWhat it does and which buildings it suits\u003c\/h3\u003e\n\u003cp\u003eThe VoltMax SCR 165 is a Thermo 2000 commercial electric boiler, here in its 165 kW, 600 V three-phase version. The manufacturer rates it at 562,980 BTU\/h. Like any hot-water boiler, it heats a closed loop that feeds baseboards, radiators, a radiant floor or hydro-air coils. Its controller goes further: it manages a second setpoint for an indirect water heater, so the same boiler can also produce domestic hot water.\u003c\/p\u003e\n\u003cp\u003eThis two-in-one role appeals to owners of residential buildings, residences and managers of commercial buildings who want space heating and hot water in the same mechanical room.\u003c\/p\u003e\n\u003ch3\u003eTwo setpoints, one boiler\u003c\/h3\u003e\n\u003cp\u003eThe Schneider Electric controller has a pump contact with or without domestic hot water priority. With priority, the indirect water heater is served first when it calls for heat; without priority, space heating and hot water share the output. The setpoint adjusts from 50 °F to 200 °F (10 °C to 93 °C), and the supplied outdoor sensor adjusts the heating water temperature to the weather.\u003c\/p\u003e\n\u003cp\u003eSCR modulation from 0 to 100%, through solid-state relays, matches output to actual demand, which limits peak power demand according to Thermo 2000. The controller shows its alarm codes in French or English and can send its alarms by email through its Ethernet port.\u003c\/p\u003e\n\u003ch3\u003eIn a Quebec building\u003c\/h3\u003e\n\u003cp\u003eOn a 600 V three-phase service, the VoltMax SCR 165 draws 158.8 A. For a residence in \u003cstrong\u003eMontreal\u003c\/strong\u003e or a building on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, the mechanical room has to hold the boiler, the indirect water heater and their pumps. The vertical boiler takes up little room there: 3 in of clearance on the sides and back, 24 in in front and 32 in above. It weighs 550 lb (250 kg) and holds 30 US gal of water.\u003c\/p\u003e\n\u003ch3\u003eThe installation, step by step\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate: electrical service, loop, emitters, hot water needs and available space. The written quote then specifies the boiler, the indirect water heater, the circulating pump and the expansion tank, the last three not being on Thermo 2000’s list of supplied items.\u003c\/p\u003e\n\u003cp\u003eOur crews install the boiler, connect the loop, the indirect water heater and the 600 V circuit, fill and purge the system, then set the two setpoints, the priority and the outdoor sensor. Thermo 2000 warrants the boiler’s tank for 10 years (limited warranty, closed-loop heating) and its electrical and mechanical components for 2 years. AirGreen, a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eGet your quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn Montreal, on the North Shore, in Laval, Longueuil or on the South Shore, the on-site estimate is free and the quote is in writing. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801495437604,"sku":"VOLTSCR600165P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR600165P3_165_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"aerotherme-a-eau-chaude-sterling-hsb03611-montreal-laval-longueuil-rive-sud-rive-nord","title":"STERLING HSB03611 Hot-Water Unit Heater | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eThe right unit heater is chosen with your water temperature\u003c\/h2\u003e\n\u003ch3\u003eWater temperature decides the output\u003c\/h3\u003e\n\u003cp\u003eThe Sterling HSB03611 is a horizontal hot-water unit heater, mid-sized in the HS series. The manufacturer publishes 26,100 BTU\/h under specific conditions: 200°F entering water, 60°F entering air and a 20°F drop between the water inlet and outlet. These conditions matter, because the heat a coil releases depends on the difference between the water temperature and the air temperature.\u003c\/p\u003e\n\u003cp\u003eAn electric boiler set high comes close to the rating. An air-to-water heat pump, on the other hand, generally works with cooler water. Sterling publishes the factors to apply: 0.857 at 180°F, 0.715 at 160°F, 0.571 at 140°F, 0.429 at 120°F and 0.286 at 100°F. We apply the one that matches your installation before recommending this model, or a neighbouring size such as the HSB02411 or the HSB04811.\u003c\/p\u003e\n\u003ch3\u003eWhich spaces it suits\u003c\/h3\u003e\n\u003cp\u003eA craftsperson’s workshop on the ground floor of a plex, the showroom of a small business, the maintenance garage of a rental building: the HSB03611 targets spaces that need a solid heat supply, delivered from the ceiling. It blows 550 CFM, or 480 CFM at reduced speed, where Sterling publishes 23,500 BTU\/h. The air outlet comes with horizontal louvers as standard.\u003c\/p\u003e\n\u003cp\u003eOn the loop side, it needs 2.7 GPM with a 20°F drop, for a pressure drop of 0.09 ft H2O. Its 25 W motor runs on 115 V, single phase, 60 Hz; it is single speed, totally enclosed with thermal overload protection. The coil is rated up to 150 PSI (1,034 kPa) or 320°F (160°C) on hot water, and also accepts a propylene glycol solution, for which Sterling publishes correction factors.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen does\u003c\/h3\u003e\n\u003cp\u003eWe start by reading the supply temperature of your electric boiler or air-to-water heat pump, then calculating the space’s heat loss. If the HSB03611 fits, our technicians hang it by rods from the connections provided, properly level. They connect it to the loop with isolation valves and air purging, make the 115 V electrical connection and install the control. Start-up includes checking the water flow and the temperature drop between inlet and outlet.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a calculation made for your building\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThe on-site estimate is free. You then receive a written quote stating the water temperature used and the resulting corrected output, with \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Sterling","offers":[{"title":"Default Title","offer_id":67801496518948,"sku":"HSB03611","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/AEROTHERME_A_EAU_CHAUDE_STERLING_HSB_03611_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082220"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr600150p3-150-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR600150P3 Commercial Electric Boiler | 150 kW - 600V 3 Phase","description":"\u003ch2\u003e150 kW on 600 V, low-maintenance and monitored remotely\u003c\/h2\u003e\n\u003ch3\u003eA commercial boiler for buildings heated with hot water\u003c\/h3\u003e\n\u003cp\u003eFor a condominium board or a property manager, the boiler is equipment you keep for a long time. Two questions come up often: how to keep maintenance simple, and how to hear about an alarm before the occupants complain. Thermo 2000’s VoltMax SCR 150 has answers on both counts. This 150 kW commercial electric boiler (511,800 BTU\/h) runs on 600 V three-phase and modulates its output from 0 to 100% with solid-state relays.\u003c\/p\u003e\n\u003cp\u003eIt suits condominiums, rental buildings and commercial buildings whose loop feeds hot-water baseboards, radiators, a radiant floor or hydro-air coils.\u003c\/p\u003e\n\u003ch3\u003eMaintenance and monitoring in a Quebec building\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 describes the VoltMax as quiet, clean and low-maintenance. Its Incoloy immersion elements are replaceable, and the Schneider Electric controller shows alarm codes on its backlit display, in French or English. With network access in the mechanical room, the Ethernet port opens a web page and sends alarms by email: the manager of a condominium in \u003cstrong\u003eLaval\u003c\/strong\u003e is alerted without waiting for an occupant’s call.\u003c\/p\u003e\n\u003cp\u003eOn a 600 V three-phase service, common in Quebec buildings, the boiler draws 144.3 A. The supplied outdoor sensor adjusts the water temperature to the weather, and the controller’s second setpoint can supply an indirect water heater for domestic hot water. The vertical format stays compact: 3 in of clearance on the sides and back, 24 in in front and 32 in above, for 550 lb (250 kg) and 30 US gal of water.\u003c\/p\u003e\n\u003ch3\u003eWhat we do, from survey to commissioning\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate, with the manager or a member of the board of directors. We check the electrical service, the loop and the emitters, then hand over a written quote. It includes the circulating pump and the expansion tank, which are not on Thermo 2000’s list of supplied items.\u003c\/p\u003e\n\u003cp\u003eOn installation day, our crews set the boiler in place, connect the piping and the 600 V circuit, fill and purge the loop, then set up the controller, the outdoor sensor and the email addresses that will receive the alarms. Thermo 2000 warrants the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years, parts and accessories.\u003c\/p\u003e\n\u003cp\u003eA family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eA project for your building\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIn Laval, Montreal, Longueuil, on the North Shore or the South Shore, ask for the free estimate: the quote is provided in writing, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801500320036,"sku":"VOLTSCR600150P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR600150P3_150_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-a-masse-thermique-thermo-2000-altsource-50-9-kw-240v","title":"THERMO 2000 AltSource 50 Thermal Mass Electric Boiler | 9 kW - 240V","description":"\u003ch2\u003eA 9 kW electric boiler that sets its output by the weather, backing up your renewable system\u003c\/h2\u003e\n\u003ch3\u003eThe essentials of the AltSource 50-9\u003c\/h3\u003e\n\u003cp\u003eThe AltSource 50-9 is a thermal mass electric boiler from Thermo 2000. Its tank holds 48 US gal of water, and its 9 kW output at 240 V, or 30,708 BTU\/h, is split into two 4.5 kW elements over two stages. Thermo 2000 designs it as the backup source of a renewable-energy heating system, such as an air-to-water heat pump, geothermal or solar, and presents it as the only high water volume electric boiler on the market.\u003c\/p\u003e\n\u003ch3\u003eA controller that follows the weather\u003c\/h3\u003e\n\u003cp\u003eAn October day does not call for the same heat as a January night. The T2 UltraSmart controller takes this into account: with the supplied outdoor sensor, it modulates output and water temperature according to the outdoor temperature. When it is mild enough, it shuts heating off. It also offers a Boost mode, a pump purge function and 24 V power for accessories.\u003c\/p\u003e\n\u003cp\u003eTwo operating modes are available: standalone electric, the default setting, or automatic transfer controlled by an external contact. We set the mode based on how your main source is connected to the loop.\u003c\/p\u003e\n\u003ch3\u003eWhich home it suits\u003c\/h3\u003e\n\u003cp\u003eThink of a house in \u003cstrong\u003eLongueuil\u003c\/strong\u003e or on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e heated by hot-water baseboards, where an air-to-water heat pump now does most of the work. The AltSource 50-9 takes over as needed and replaces an old electric boiler at the same time. It fits in a tight space: 22 in in diameter, 25 1\/2 in deep with the door and 56 7\/16 in high, for a weight of 280 lb before filling.\u003c\/p\u003e\n\u003cp\u003eOn the electrical side, Thermo 2000 lists a 50 A breaker and Cu 8 \/ Al 6 wire gauge at 240 V single phase. If the building has a 208 V supply, output becomes 6.8 kW (32.6 A). The loop connects in 1 in NPT and operates at a maximum pressure of 30 psi; the manufacturer recommends a #30 expansion tank with baseboards or a radiant floor, and a #60 with cast-iron radiators.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eThe on-site estimate is free. We examine the main source, the hot-water loop, the electrical panel and the planned location, then give you a written quote that specifies the boiler, circulator, expansion tank and electrical work. At installation, we set the unit in place, connect it, mount the outdoor sensor, fill and purge the system, then set the controller’s heating curve with you.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 covers the tank for 15 years in residential use and the electrical and mechanical components for 2 years. AirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003eGet your quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe install in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. The estimate is free, the quote is in writing and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801501139236,"sku":"ALTSOURCE50-9","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_ALTSOURCE_50_9_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"aerotherme-a-eau-chaude-sterling-hsb04811-montreal-laval-longueuil-rive-sud-rive-nord","title":"STERLING HSB04811 Hot-Water Unit Heater | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eHeat the warehouse with the boiler that already heats your offices\u003c\/h2\u003e\n\u003ch3\u003eWhat the Sterling HSB04811 is\u003c\/h3\u003e\n\u003cp\u003eMany commercial buildings have an electric boiler for the offices and a poorly heated warehouse or workshop at the back. The Sterling HSB04811 lets you extend the hot-water loop that far. It is a horizontal unit heater: water flows through a coil, a propeller fan blows air across it, and the heat comes down from the ceiling to the work area. Because it hangs, it leaves the floor free for shelving, carts and pallets.\u003c\/p\u003e\n\u003cp\u003eSterling publishes 34,800 BTU\/h with 200°F entering water, 60°F entering air and a 20°F drop. Airflow is 750 CFM, with an outlet velocity of 550 FPM. This size is the first in the series with the 1\/20 HP motor: a single-speed 115 V motor, totally enclosed with thermal overload protection.\u003c\/p\u003e\n\u003ch3\u003eThe technical points we check\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eWater temperature.\u003c\/strong\u003e The rating applies at 200°F. Sterling publishes the factors to apply below that: 0.857 at 180°F, 0.715 at 160°F, 0.571 at 140°F, 0.429 at 120°F.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFlow and circulator.\u003c\/strong\u003e The unit needs 3.5 GPM with a 20°F drop, for a pressure drop of 0.12 ft H2O. If you add several unit heaters, the circulator and the boiler must cover them all.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eLoop fluid.\u003c\/strong\u003e Hot water or a propylene glycol solution: Sterling publishes correction factors for glycol.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eStructure.\u003c\/strong\u003e The unit hangs by rods from the connections provided and must be level.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eElectrical.\u003c\/strong\u003e 115 V, single phase, 60 Hz.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe coil is rated up to 150 PSI (1,034 kPa) or 320°F (160°C) on hot water and factory tested at 200 psig (1,379 kPa) under water, which suits the closed loops of the commercial buildings we serve.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eAfter a visit and a heat-loss calculation for the warehouse, we propose the number of units and their location. Our technicians hang them, connect them to the loop with isolation valves and air purging, make the electrical connection and install the controls. Each unit can have its own control, so the warehouse can be kept at a different temperature from the offices. We finish with start-up and a check of the flows.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet’s plan your warehouse\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free on-site estimate. You will receive a written quote detailing the number of unit heaters, the water temperature used and the work on the loop. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Sterling","offers":[{"title":"Default Title","offer_id":67801507496228,"sku":"HSB04811","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/AEROTHERME_A_EAU_CHAUDE_STERLING_HSB_04811_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082220"},{"product_id":"chaudiere-electrique-commerciale-thermo-2000-voltmax-scr-voltscr600144p3-144-kw-600v-3-phases","title":"THERMO 2000 VoltMax SCR VOLTSCR600144P3 Commercial Electric Boiler | 144 kW - 600V 3 Phase","description":"\u003ch2\u003eA building heated on its own schedule, with 144 kW on 600 V\u003c\/h2\u003e\n\u003ch3\u003eA boiler for buildings that empty out in the evening\u003c\/h3\u003e\n\u003cp\u003eA school, a community centre or an office building does not have the same needs in the middle of a weekday as on a Sunday evening. Thermo 2000’s VoltMax SCR 144 is a 144 kW commercial electric boiler (491,328 BTU\/h), here in its 600 V three-phase version. Its Schneider Electric controller handles schedules, adjusts the water temperature with the supplied outdoor sensor and modulates output from 0 to 100% through solid-state relays (SCR) combined with relay stages.\u003c\/p\u003e\n\u003cp\u003eIt suits managers of institutional and commercial buildings, school service centres, municipalities and organizations that heat their premises with radiators, hot-water baseboards or radiant floors. It can also supply an indirect water heater through its second setpoint.\u003c\/p\u003e\n\u003ch3\u003eWhat it brings to a Quebec building\u003c\/h3\u003e\n\u003cp\u003e600 V three-phase power is common in Quebec’s institutional buildings; there, the VoltMax SCR 144 draws 138.6 A. In a community centre in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, for example, the outdoor sensor lowers the water temperature on mild autumn days, and the controller raises it during a cold snap, within the 50 °F to 200 °F setpoint range. In the evening and on weekends, the schedules take over.\u003c\/p\u003e\n\u003cp\u003eFor a manager in charge of several buildings, the Ethernet port changes daily life: a web page shows the boiler’s status and alarms arrive by email. The controller displays in French or English, in °C or °F, and also communicates over BACnet IP and MS-TP. For safety, Thermo 2000 supplies two limit controls, a factory-installed relief valve and, above 60 kW, a standard low-water cutoff.\u003c\/p\u003e\n\u003ch3\u003eHow we install it\u003c\/h3\u003e\n\u003cp\u003eIt all starts with a free on-site estimate, scheduled around the occupancy of your premises. We look at the 600 V service, the loop, the emitters and the access to the mechanical room: the boiler weighs 550 lb (250 kg) and needs 24 in in front, 32 in above and 3 in on the sides and back. You then receive a written quote that includes the circulating pump and the expansion tank, which are not on Thermo 2000’s list of supplied items.\u003c\/p\u003e\n\u003cp\u003eAt installation, our crews connect the piping and the electrical circuit, fill and purge the loop, then program the schedules, the outdoor reset curve and the email alarms with your building manager. Thermo 2000 warrants the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003ch3\u003ePlanning the replacement\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIs your building in Longueuil, Montreal, Laval, on the South Shore or the North Shore? Let’s schedule the free estimate: you will receive a written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801517064484,"sku":"VOLTSCR600144P3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_COMMERCIALE_THERMO_2000_VOLTMAX_SCR_VOLTSCR600144P3_144_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082242"},{"product_id":"chaudiere-electrique-a-masse-thermique-thermo-2000-altsource-70-9-kw-240v","title":"THERMO 2000 AltSource 70 Thermal Mass Electric Boiler | 9 kW - 240V","description":"\u003ch2\u003eCast-iron radiators, a renewable source and a 9 kW backup with 71 US gal of water\u003c\/h2\u003e\n\u003ch3\u003eThe case of plexes heated with hot water\u003c\/h3\u003e\n\u003cp\u003eMany \u003cstrong\u003eMontreal\u003c\/strong\u003e plexes have kept their cast-iron radiators. Owners who add an air-to-water heat pump, or another renewable-energy system, need a backup that can supply those radiators at high temperature. That is exactly the role of the AltSource 70-9: its water can be heated from 50 °F to 190 °F (10 °C to 88 °C), and Thermo 2000 gives specific recommendations for cast-iron radiators, baseboards and radiant floors.\u003c\/p\u003e\n\u003ch3\u003eWhat the AltSource 70-9 is\u003c\/h3\u003e\n\u003cp\u003eIt is a thermal mass electric boiler, which Thermo 2000 presents as the only high water volume electric boiler on the market. Its tank holds 71 US gal of water. Its 9 kW output at 240 V, or 30,708 BTU\/h, comes from two 4.5 kW elements that come on in two stages. The T2 UltraSmart controller, supplied with its outdoor sensor, modulates output and water temperature on the outdoor temperature and shuts heating off in warm weather.\u003c\/p\u003e\n\u003cp\u003eThe controller runs in standalone electric mode by default. In automatic transfer mode, an external contact controls the unit when a main source is connected.\u003c\/p\u003e\n\u003ch3\u003eWhat to plan for in the mechanical room\u003c\/h3\u003e\n\u003cp\u003eA 71 US gal reserve needs a solid location. The unit weighs 380 lb before it is filled and measures 24 in in diameter and 28 in deep with the door. In a plex basement, we check the stairs, door frames and floor before confirming the location.\u003c\/p\u003e\n\u003cp\u003eOn the loop, the AltSource connects in 1 1\/4 in male NPT and operates at a maximum pressure of 30 psi. With cast-iron radiators, Thermo 2000 recommends a #90 expansion tank; with baseboards or a radiant floor, a #60. The circulator and tank are not among the supplied parts and are listed in the quote.\u003c\/p\u003e\n\u003cp\u003eOn the electrical side, it needs a 240 V single-phase circuit with a 50 A breaker and Cu 8 \/ Al 6 wire gauge. In a building with a 208 V supply, output becomes 6.8 kW (32.6 A).\u003c\/p\u003e\n\u003ch3\u003eFrom estimate to commissioning\u003c\/h3\u003e\n\u003cp\u003eWe start with a free on-site estimate: condition of the radiator loop, main source, electrical panel, access. You then receive a written quote. On installation day, we install the boiler, connect it to the loop and the electrical circuit, mount the outdoor sensor and supplied accessories, fill and purge the system, then set the controller.\u003c\/p\u003e\n\u003cp\u003eThermo 2000 covers the tank for 15 years in residential use and 10 years in commercial use, and the electrical and mechanical components for 2 years. AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01.\u003c\/p\u003e\n\u003ch3\u003eAsk for your free estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWe serve Montreal, Laval, Longueuil, the North Shore and the South Shore. Receive a written quote for your AltSource 70, with \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801517556004,"sku":"ALTSOURCE70-9","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_ALTSOURCE_70_9_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082241"},{"product_id":"aerotherme-a-eau-chaude-sterling-hsb06011-montreal-laval-longueuil-rive-sud-rive-nord","title":"STERLING HSB06011 Hot-Water Unit Heater | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eKeep the shop warm, even when the garage door opens\u003c\/h2\u003e\n\u003ch3\u003eA unit heater designed for door zones\u003c\/h3\u003e\n\u003cp\u003eIn an auto repair shop, an equipment shed or the entrance to an underground parking garage, heat is lost mostly through the large door. The Sterling HSB06011 answers that need with an airflow of 900 CFM and an outlet velocity of 650 FPM. Hung from the ceiling, it takes the hot water from your loop, runs it through its coil and sends the warmed air down through horizontal louvers that come standard.\u003c\/p\u003e\n\u003cp\u003eWith 200°F entering water, 60°F entering air and a 20°F drop, Sterling publishes 43,600 BTU\/h. At reduced speed, the rating becomes 39,200 BTU\/h at 700 CFM. The 1\/20 HP motor runs on 115 V, single speed; it is totally enclosed with thermal overload protection.\u003c\/p\u003e\n\u003ch3\u003eIn Quebec: garage doors, long winters and glycol loops\u003c\/h3\u003e\n\u003cp\u003eA door zone is exposed to the cold. When part of the loop runs through a space that can freeze, such as a parking ramp, it is often filled with propylene glycol rather than plain water. Sterling publishes correction factors for that mix, and we apply them to the output calculation.\u003c\/p\u003e\n\u003cp\u003eWater temperature matters just as much. Your electric boiler or air-to-water heat pump does not necessarily supply 200°F. The factors Sterling publishes are 0.857 at 180°F, 0.715 at 160°F, 0.571 at 140°F and 0.429 at 120°F. The right choice is therefore made with the actual temperature, a heat-loss calculation, and allowing for door openings.\u003c\/p\u003e\n\u003cp\u003eOn the hydronic side, the unit needs 4.4 GPM with a 20°F drop, for a pressure drop of 0.17 ft H2O.\u003c\/p\u003e\n\u003ch3\u003eHow we install it\u003c\/h3\u003e\n\u003cp\u003eWe visit the site and look at the door, the free height and the ceiling structure. Mounting height and air throw are not in the data we verified: we set the location with Sterling’s installation manual. Then our technicians:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ehang the unit heater by rods, properly level;\u003c\/li\u003e\n\u003cli\u003econnect it to the loop, with isolation valves and air purging;\u003c\/li\u003e\n\u003cli\u003econnect the 115 V supply and the control;\u003c\/li\u003e\n\u003cli\u003estart it up and check the flow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). We serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eYour garage door, your calculation\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free on-site estimate. You receive a written quote that accounts for your door, your loop and its temperature, with \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Sterling","offers":[{"title":"Default Title","offer_id":67801522241828,"sku":"HSB06011","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/AEROTHERME_A_EAU_CHAUDE_STERLING_HSB_06011_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082220"},{"product_id":"chaudiere-electrique-avec-eau-chaude-integree-thermo-2000-combomax-ultra-50-9-kw-240v","title":"THERMO 2000 ComboMax Ultra 50 Electric Boiler with Integrated Hot Water | 9 kW - 240V","description":"\u003ch2\u003eTwo appliances replaced by one: 9 kW of heating and instantaneous hot water in 48 US gal\u003c\/h2\u003e\n\u003ch3\u003eThe typical case: a boiler and a water heater side by side\u003c\/h3\u003e\n\u003cp\u003eIn many basements in \u003cstrong\u003eMontreal\u003c\/strong\u003e and \u003cstrong\u003eLongueuil\u003c\/strong\u003e, it is the same scene: an electric boiler on the wall, a water heater beside it, pipes crossing between the two. Thermo 2000’s 9 kW ComboMax Ultra 50 does the work of both. It heats the home’s hot-water loop and makes domestic hot water, in a single 48 US gal tank that takes the space of a conventional water heater: 60 in high and 22 in in diameter.\u003c\/p\u003e\n\u003cp\u003eThe principle is simple. The tank holds the heating water. Parallel copper coils are immersed in it; drinking water flows through them and heats up on the way. No domestic hot water is stored, which, according to the manufacturer, reduces the risk of Legionella. Water arrives hot in under 7 seconds, again according to Thermo 2000.\u003c\/p\u003e\n\u003ch3\u003e9 kW on two identical elements\u003c\/h3\u003e\n\u003cp\u003eHeating relies on two 4.5 kW elements split over two stages, for 30,708 BTU\/h at 240 V. This size suits a medium-sized home heated by radiators, hot-water baseboards or radiant floors, once the heating load is confirmed. For hot water, Thermo 2000 publishes 55 US gal in 10 minutes and 99 US gal in one hour, at 110 °F, with cold water at 40 °F and boiler water at 180 °F.\u003c\/p\u003e\n\u003cp\u003eThe T2 UltraSmart controller gives priority to domestic hot water, sets its temperature and runs the heating pump when the thermostat calls. The required electrical circuit is 240 V single phase with a 50 A breaker and Cu 8 or Al 6 wire; at 208 V, output is multiplied by 0.75 according to the manufacturer.\u003c\/p\u003e\n\u003ch3\u003eAn installation planned from start to finish\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate, in \u003cstrong\u003eLaval\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e or in \u003cstrong\u003eMontreal\u003c\/strong\u003e: we note the heating load, your hot water needs, the panel’s capacity and the location.\u003c\/li\u003e\n\u003cli\u003eWritten quote: unit, loop components, removal of the old appliances if needed, steps of the work.\u003c\/li\u003e\n\u003cli\u003eInstallation: setting in place, connection by qualified personnel to the heating loop (1 in male NPT) and to domestic water (3\/4 in female NPT), then the electrical connection.\u003c\/li\u003e\n\u003cli\u003eStart-up: filling, purging, setting the controller and testing heating and hot water.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eSeveral accessories supplied by Thermo 2000 arrive already mounted, including the 12 psi pressure regulator with check valve, the thermostatic mixing valve and the automatic air vent. AirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical).\u003c\/p\u003e\n\u003ch3\u003eWarranty and next step\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 covers the tank and coils for 15 years in residential use (10 years in commercial use), and electrical and mechanical components for 2 years.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFree up your mechanical room: ask for a free estimate and a written quote for the 9 kW ComboMax Ultra 50, with \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801537806628,"sku":"COMBOU50-9","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUDIERE_ELECTRIQUE_THERMO_2000_COMBOMAX_ULTRA_50_9_KW_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082265"}],"url":"https:\/\/airgreen.ca\/en\/collections\/chauffage-hydronique-installation-a-montreal-laval-longueuil-rive-sud-et-rive-nord.oembed","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}