{"title":"YORK Central Air Conditioner | Montreal, Laval, Longueuil, South Shore and North Shore","description":null,"products":[{"product_id":"climatiseur-central-york-yc3-lx-1-5-tonnes-18000-btu-r454b","title":"YORK YC3 LX Central Air Conditioner | 1.5 Tons - 18000 BTU - R454B","description":"\u003ch2\u003eA small York size to add central air without overloading the panel\u003c\/h2\u003e\n\u003cp\u003eThe YC318E2S11 is the 1.5-ton (18,000 BTU\/h) condensing unit of the York YC3 (LX) series, the smallest of the 7 sizes we offer in this series. It runs on R-454B, with a single-stage rotary compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC3 is the basic model of York's R-454B LX range. Single-stage compressor, rotary at 1.5 and 2 tons and scroll in the other sizes, G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 (at least 500 h), up to 80 ft of piping: a simple, durable build. With the approved low-ambient kits it can cool down to 20°F (-7°C), useful when a room overheats in spring.\u003c\/p\u003e\n\u003ch3\u003eWhich homes does it suit?\u003c\/h3\u003e\n\u003cp\u003eThis size is aimed at condos, townhouses and modest bungalows that already have ductwork. A bigger unit would short-cycle there. In a small home, cycle length is what matters: the longer the cycles, the drier the air and the more real the comfort. On the electrical side, a 15 A maximum breaker is enough, which often avoids major panel work.\u003c\/p\u003e\n\u003ch3\u003eWhat the manufacturer's spec sheet says\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 13.4 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 73 dBA. It needs a 208\/230 V single-phase circuit with a 9.1 A minimum circuit ampacity and a 15 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 2.38 lb (1.08 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 24 x 24 in at the base and 26 3\/4 in high, with an operating weight of 120 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eR-454B replaces R-410A in new air conditioners sold in Canada. It is an A2L-class refrigerant: we install it with an indoor section approved for it, following the manufacturer's requirements.\u003c\/p\u003e\n\u003cp\u003eThis condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.\u003c\/p\u003e\n\u003cp\u003eSame size, other series: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc6-lx-1-5-tonnes-18000-btu-r454b\"\u003eYork YC6 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-1-5-tonnes-18000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-1-5-tonnes-18000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 3\/4 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YC318E2S11: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395028939044,"sku":"YC318E2S11","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC3_YC318E2S11_00_1_5_TONNES_18000_BTU_R454B_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692127"},{"product_id":"climatiseur-central-york-ycg-lx-2-tonnes-24000-btu-r410a","title":"YORK YCG LX Central Air Conditioner | 2 Tons - 24000 BTU - R410A","description":"\u003ch2\u003eA small York size to add central air without overloading the panel\u003c\/h2\u003e\n\u003cp\u003eAt 24,000 BTU\/h, the YCG24B21S is the 2-ton size of the York YCG (LX) series, the smallest of the 6 sizes we offer in this series. It is the outdoor unit of an R-410A central air conditioner, fitted with a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YCG is a York LX R-410A condensing unit, offered from 2 to 5 tons on clearance. Its paint is tested for at least 750 hours of salt spray, more than the other LX models. The limited warranty is 10 years on the compressor, with 10 years on parts if the unit is registered.\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eThis size is aimed at condos, townhouses and modest bungalows that already have ductwork. A bigger unit would short-cycle there. A well-chosen size dehumidifies better: an oversized unit cools quickly, shuts off right away and leaves the house cool but clammy. On the electrical side, a 25 A maximum breaker is enough, which often avoids major panel work.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eThe spec sheet lists a sound power of 72 dBA. Electrical: 208\/230 V single-phase circuit, 16.4 A minimum ampacity, 25 A maximum time-delay fuse or breaker. The unit ships with a factory charge of 3.62 lb (1.64 kg) of R-410A, which our technicians adjust to the actual piping length.\u003c\/p\u003e\n\u003cp\u003eThe cabinet measures 29 1\/4 x 29 1\/4 in at the base and 30 in high, with an operating weight of 150 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eThis model runs on R-410A, a refrigerant that manufacturers are gradually replacing with R-454B and R-32 in their new series. It is offered while our suppliers' stock lasts, and it suits replacing an R-410A condensing unit on a compatible coil.\u003c\/p\u003e\n\u003cp\u003eThis condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.\u003c\/p\u003e\n\u003cp\u003eOther York series offered at 2 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-2-tonnes-24000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxt-affinity-2-tonnes-24000-btu-r410a\"\u003eYork YXT Affinity\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxv-affinity-2-tonnes-24000-btu-r410a\"\u003eYork YXV Affinity\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 3\/4 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm whether 2 tons is the right size, check the panel and the ducts, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395054137636,"sku":"YCG24B21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YCG_YCG24B21S_00_2_TONNES_24000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692131"},{"product_id":"climatiseur-central-york-yc4-lx-2-tonnes-24000-btu-r454b","title":"YORK YC4 LX Central Air Conditioner | 2 Tons - 24000 BTU - R454B","description":"\u003ch2\u003eA small York size to add central air without overloading the panel\u003c\/h2\u003e\n\u003cp\u003eThe YC424E2S11 is the 2-ton (24,000 BTU\/h) condensing unit of the York YC4 (LX) series, the smallest of the 6 sizes we offer in this series. It runs on R-454B, with a single-stage scroll compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC4 moves York's R-454B LX range one step up in efficiency, up to 16 SEER2 depending on size and match. It comes from 2 to 5 tons, with a single-stage scroll compressor and the range's G90-equivalent steel cabinet. The limited warranty is 10 years on the compressor.\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eIt is often chosen to add air conditioning to a small house heated by an electric furnace: a coil is added on the furnace, and the condensing unit does the rest outside. In a small home, cycle length is what matters: the longer the cycles, the drier the air and the more real the comfort. On the electrical side, a 20 A maximum breaker is enough, which often avoids major panel work.\u003c\/p\u003e\n\u003ch3\u003eTechnical data worth knowing\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 14.3 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 71 dBA. It needs a 208\/230 V single-phase circuit with a 13.4 A minimum circuit ampacity and a 20 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 2.62 lb (1.19 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 29 1\/4 x 29 1\/4 in at the base and 30 in high, with an operating weight of 150 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eRunning on R-454B, this condensing unit meets the Canadian rules now in force for new air conditioners. R-454B is mildly flammable (A2L class): the indoor section must be approved for it, and the installation follows the manufacturer's instructions.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eTo compare, still at 2 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc3-lx-2-tonnes-24000-btu-r454b\"\u003eYork YC3 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc6-lx-2-tonnes-24000-btu-r454b\"\u003eYork YC6 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-2-tonnes-24000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 3\/4 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm whether 2 tons is the right size, check the panel and the ducts, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395054432548,"sku":"YC424E2S11","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC4_YC424E2S11_00_2_TONNES_24000_BTU_R454B_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yc3-lx-2-tonnes-24000-btu-r454b","title":"YORK YC3 LX Central Air Conditioner | 2 Tons - 24000 BTU - R454B","description":"\u003ch2\u003eA small York size to add central air without overloading the panel\u003c\/h2\u003e\n\u003cp\u003eAt 24,000 BTU\/h, the YC324E2S11 is the 2-ton size of the York YC3 (LX) series, between the 1.5-ton and 2.5-ton sizes of the same series. It is the outdoor unit of an R-454B central air conditioner, fitted with a single-stage rotary compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC3 is the basic model of York's R-454B LX range. Single-stage compressor, rotary at 1.5 and 2 tons and scroll in the other sizes, G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 (at least 500 h), up to 80 ft of piping: a simple, durable build. With the approved low-ambient kits it can cool down to 20°F (-7°C), useful when a room overheats in spring.\u003c\/p\u003e\n\u003ch3\u003eThe right size for your home\u003c\/h3\u003e\n\u003cp\u003eThis size is aimed at condos, townhouses and modest bungalows that already have ductwork. A bigger unit would short-cycle there. A well-chosen size dehumidifies better: an oversized unit cools quickly, shuts off right away and leaves the house cool but clammy. On the electrical side, a 20 A maximum breaker is enough, which often avoids major panel work.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 13.4 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 74 dBA. Electrical: 208\/230 V single-phase circuit, 12.7 A minimum ampacity, 20 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 2.75 lb (1.25 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 24 x 24 in at the base and 33 1\/4 in high, with an operating weight of 135 lb, 15 lb more than the 1.5-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eRunning on R-454B, this condensing unit meets the Canadian rules now in force for new air conditioners. R-454B is mildly flammable (A2L class): the indoor section must be approved for it, and the installation follows the manufacturer's instructions.\u003c\/p\u003e\n\u003cp\u003eThis condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.\u003c\/p\u003e\n\u003cp\u003eTo compare, still at 2 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc6-lx-2-tonnes-24000-btu-r454b\"\u003eYork YC6 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc4-lx-2-tonnes-24000-btu-r454b\"\u003eYork YC4 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-2-tonnes-24000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eA Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 3\/4 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTorn between two sizes or two series? Ask for a free estimate: we compare the options for your home and give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395054465316,"sku":"YC324E2S11","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC3_YC324E2S11_00_2_TONNES_24000_BTU_R454B_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692127"},{"product_id":"climatiseur-central-york-yc6-lx-1-5-tonnes-18000-btu-r454b","title":"YORK YC6 LX Central Air Conditioner | 1.5 Tons - 18000 BTU - R454B","description":"\u003ch2\u003e1.5 tons of central air for a condo, a townhouse or a small bungalow\u003c\/h2\u003e\n\u003cp\u003eAt 18,000 BTU\/h, the YC618E2S11 is the 1.5-ton size of the York YC6 (LX) series, the smallest of the 5 sizes we offer in this series. It is the outdoor unit of an R-454B central air conditioner, fitted with a single-stage rotary compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC6 is the two-stage series of York's R-454B LX range, up to 18 SEER2 depending on size and match. From 2 to 5 tons, its two-stage scroll compressor spends most of its time at reduced capacity, for drier air and quieter operation, and only goes to full capacity when needed. The 1.5-ton size uses a single-stage rotary compressor instead.\u003c\/p\u003e\n\u003ch3\u003eWhich homes does it suit?\u003c\/h3\u003e\n\u003cp\u003eIt is the typical size for a condo or a townhouse where the electrical panel is already well filled and outdoor space is tight. In a small home, cycle length is what matters: the longer the cycles, the drier the air and the more real the comfort. On the electrical side, a 15 A maximum breaker is enough, which often avoids major panel work.\u003c\/p\u003e\n\u003ch3\u003eWhat the manufacturer's spec sheet says\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 16 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. At 71 dBA of sound power, it is the quietest size in the series. It needs a 208\/230 V single-phase circuit with a 9.3 A minimum circuit ampacity and a 15 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 3.62 lb (1.64 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 29 1\/4 x 29 1\/4 in at the base and 36 1\/4 in high, with an operating weight of 165 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eR-454B has a much lower global warming potential than the R-410A it replaces. Like any A2L refrigerant, it requires a compatible indoor section and an installation that follows the manufacturer's instructions.\u003c\/p\u003e\n\u003cp\u003eNote: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.\u003c\/p\u003e\n\u003cp\u003eSame size, other series: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc3-lx-1-5-tonnes-18000-btu-r454b\"\u003eYork YC3 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-1-5-tonnes-18000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-1-5-tonnes-18000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eA Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 3\/4 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eWe work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTorn between two sizes or two series? Ask for a free estimate: we compare the options for your home and give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395054530852,"sku":"YC618E2S11","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC6_YC618E2S11_00_1_5_TONNES_18000_BTU_R454B_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yc2d-lx-1-5-tonnes-18000-btu-r410a","title":"YORK YC2D LX Central Air Conditioner | 1.5 Tons - 18000 BTU - R410A","description":"\u003ch2\u003e1.5 tons of central air for a condo, a townhouse or a small bungalow\u003c\/h2\u003e\n\u003cp\u003eThe YC2D18SB21S is the 1.5-ton (18,000 BTU\/h) condensing unit of the York YC2D (LX) series, the smallest of the 7 sizes we offer in this series. It runs on R-410A, with a single-stage rotary compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC2D belongs to York's LX range, here in R-410A and on clearance. It is the range's basic model, rated 13.4 SEER2 by York, with a single-stage compressor (rotary at 1.5 and 2 tons, scroll in the other sizes), G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 (at least 500 h). The limited warranty is 10 years on the compressor, and the parts warranty goes from 5 to 10 years with registration.\u003c\/p\u003e\n\u003ch3\u003eWhich homes does it suit?\u003c\/h3\u003e\n\u003cp\u003eThis size is aimed at condos, townhouses and modest bungalows that already have ductwork. A bigger unit would short-cycle there. In a small home, cycle length is what matters: the longer the cycles, the drier the air and the more real the comfort. On the electrical side, a 15 A maximum breaker is enough, which often avoids major panel work.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eYork publishes a range of 13.4 to 15 SEER2 for this size, depending on the matched indoor section; the condensing unit alone has no certified rating. The spec sheet lists a sound power of 73 dBA. Electrical: 208\/230 V single-phase circuit, 8.9 A minimum ampacity, 15 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 3.19 lb (1.45 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 24 x 24 in at the base and 30 in high, with an operating weight of 120 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eRunning on R-410A, this condensing unit is part of the stock still available: manufacturers are gradually moving to R-454B and R-32 in their new series. It is a good option to replace an R-410A unit while keeping a coil in good condition.\u003c\/p\u003e\n\u003cp\u003eNote: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.\u003c\/p\u003e\n\u003cp\u003eTo compare, still at 1.5 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-1-5-tonnes-18000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc6-lx-1-5-tonnes-18000-btu-r454b\"\u003eYork YC6 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc3-lx-1-5-tonnes-18000-btu-r454b\"\u003eYork YC3 LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 3\/4 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTorn between two sizes or two series? Ask for a free estimate: we compare the options for your home and give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395054792996,"sku":"YC2D18SB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC2D_YC2D18SB21S_00_1_5_TONNES_18000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692128"},{"product_id":"climatiseur-central-york-yc2e-lx-1-5-tonnes-18000-btu-r410a","title":"YORK YC2E LX Central Air Conditioner | 1.5 Tons - 18000 BTU - R410A","description":"\u003ch2\u003eThe 1.5-ton YC2E: cooling a small home that already has ductwork\u003c\/h2\u003e\n\u003cp\u003eA 1.5-ton size, or 18,000 BTU\/h: the YC2E18SB21S belongs to the York YC2E (LX) series, the smallest of the 7 sizes we offer in this series. This R-410A condensing unit uses a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC2E is the 14.3 SEER2 version of York's R-410A LX range, offered on clearance while stock lasts. Same single-stage scroll compressor and same cabinet of G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 as the YC2D, with better efficiency. With the approved low-ambient kits it can cool down to 20°F (-7°C).\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eIt is often chosen to add air conditioning to a small house heated by an electric furnace: a coil is added on the furnace, and the condensing unit does the rest outside. A well-chosen size dehumidifies better: an oversized unit cools quickly, shuts off right away and leaves the house cool but clammy. On the electrical side, a 20 A maximum breaker is enough, which often avoids major panel work.\u003c\/p\u003e\n\u003ch3\u003eWhat the manufacturer's spec sheet says\u003c\/h3\u003e\n\u003cp\u003eYork publishes a range of 14.3 to 16.5 SEER2 for this size, depending on the matched indoor section; the condensing unit alone has no certified rating. The spec sheet lists a sound power of 73 dBA. It needs a 208\/230 V single-phase circuit with a 11.8 A minimum circuit ampacity and a 20 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 3.44 lb (1.56 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 29 1\/4 x 29 1\/4 in at the base and 30 in high, with an operating weight of 150 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eRunning on R-410A, this condensing unit is part of the stock still available: manufacturers are gradually moving to R-454B and R-32 in their new series. It is a good option to replace an R-410A unit while keeping a coil in good condition.\u003c\/p\u003e\n\u003cp\u003eThis condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.\u003c\/p\u003e\n\u003cp\u003eOther York series offered at 1.5 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-1-5-tonnes-18000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc6-lx-1-5-tonnes-18000-btu-r454b\"\u003eYork YC6 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc3-lx-1-5-tonnes-18000-btu-r454b\"\u003eYork YC3 LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eA Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 3\/4 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YC2E18SB21S: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395056759076,"sku":"YC2E18SB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC2E_YC2E18SB21S_00_1_5_TONNES_18000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692129"},{"product_id":"climatiseur-central-york-ycg-lx-2-5-tonnes-30000-btu-r410a","title":"YORK YCG LX Central Air Conditioner | 2.5 Tons - 30000 BTU - R410A","description":"\u003ch2\u003eThe 2.5-ton YCG for a bungalow or cottage with ductwork\u003c\/h2\u003e\n\u003cp\u003eAt 30,000 BTU\/h, the YCG30B21S is the 2.5-ton size of the York YCG (LX) series, between the 2-ton and 3-ton sizes of the same series. It is the outdoor unit of an R-410A central air conditioner, fitted with a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YCG is a York LX R-410A condensing unit, offered from 2 to 5 tons on clearance. Its paint is tested for at least 750 hours of salt spray, more than the other LX models. The limited warranty is 10 years on the compressor, with 10 years on parts if the unit is registered.\u003c\/p\u003e\n\u003ch3\u003eThe right size for your home\u003c\/h3\u003e\n\u003cp\u003eFor a mid-size single-family house with an electric furnace or a fan coil in the basement, it is often the balance point between comfort and consumption. Before confirming the size, we look at the insulation, the orientation of the windows and the capacity of the ducts.\u003c\/p\u003e\n\u003ch3\u003eWhat the manufacturer's spec sheet says\u003c\/h3\u003e\n\u003cp\u003eThe spec sheet lists a sound power of 72 dBA. Electrical: 208\/230 V single-phase circuit, 18.8 A minimum ampacity, 30 A maximum time-delay fuse or breaker. The unit ships with a factory charge of 4.69 lb (2.13 kg) of R-410A, which our technicians adjust to the actual piping length.\u003c\/p\u003e\n\u003cp\u003eThe cabinet measures 35 1\/4 x 31 3\/4 in at the base and 36 1\/4 in high, with an operating weight of 165 lb, 15 lb more than the 2-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eRunning on R-410A, this condensing unit is part of the stock still available: manufacturers are gradually moving to R-454B and R-32 in their new series. It is a good option to replace an R-410A unit while keeping a coil in good condition.\u003c\/p\u003e\n\u003cp\u003eThis condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.\u003c\/p\u003e\n\u003cp\u003eTo compare, still at 2.5 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-2-5-tonnes-30000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2f-lx-2-5-tonnes-30000-btu-r410a\"\u003eYork YC2F LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-2-5-tonnes-30000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 3\/4 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YCG30B21S: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395070980388,"sku":"YCG30B21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YCG_YCG30B21S_00_2_5_TONNES_30000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yc3-lx-2-5-tonnes-30000-btu-r454b","title":"YORK YC3 LX Central Air Conditioner | 2.5 Tons - 30000 BTU - R454B","description":"\u003ch2\u003eThe 2.5-ton YC3 for a bungalow or cottage with ductwork\u003c\/h2\u003e\n\u003cp\u003eThe YC330E2S11 is the 2.5-ton (30,000 BTU\/h) condensing unit of the York YC3 (LX) series, between the 2-ton and 3-ton sizes of the same series. It runs on R-454B, with a single-stage scroll compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC3 is the basic model of York's R-454B LX range. Single-stage compressor, rotary at 1.5 and 2 tons and scroll in the other sizes, G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 (at least 500 h), up to 80 ft of piping: a simple, durable build. With the approved low-ambient kits it can cool down to 20°F (-7°C), useful when a room overheats in spring.\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eFor a mid-size single-family house with an electric furnace or a fan coil in the basement, it is often the balance point between comfort and consumption. Before confirming the size, we look at the insulation, the orientation of the windows and the capacity of the ducts.\u003c\/p\u003e\n\u003ch3\u003eTechnical data worth knowing\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 13.4 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 73 dBA. It needs a 208\/230 V single-phase circuit with a 16.3 A minimum circuit ampacity and a 25 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 2.81 lb (1.28 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 24 x 24 in at the base and 36 1\/4 in high, with an operating weight of 140 lb, 5 lb more than the 2-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eR-454B replaces R-410A in new air conditioners sold in Canada. It is an A2L-class refrigerant: we install it with an indoor section approved for it, following the manufacturer's requirements.\u003c\/p\u003e\n\u003cp\u003eNote: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.\u003c\/p\u003e\n\u003cp\u003eSame size, other series: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc4-lx-2-5-tonnes-30000-btu-r454b\"\u003eYork YC4 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2f-lx-2-5-tonnes-30000-btu-r410a\"\u003eYork YC2F LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-2-5-tonnes-30000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 3\/4 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YC330E2S11: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395071275300,"sku":"YC330E2S11","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC3_YC330E2S11_00_2_5_TONNES_30000_BTU_R454B_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692127"},{"product_id":"climatiseur-central-york-yc4-lx-2-5-tonnes-30000-btu-r454b","title":"YORK YC4 LX Central Air Conditioner | 2.5 Tons - 30000 BTU - R454B","description":"\u003ch2\u003eThe 2.5-ton YC4 for a bungalow or cottage with ductwork\u003c\/h2\u003e\n\u003cp\u003eThe YC430E2S11 is the 2.5-ton (30,000 BTU\/h) condensing unit of the York YC4 (LX) series, between the 2-ton and 3-ton sizes of the same series. It runs on R-454B, with a single-stage scroll compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC4 moves York's R-454B LX range one step up in efficiency, up to 16 SEER2 depending on size and match. It comes from 2 to 5 tons, with a single-stage scroll compressor and the range's G90-equivalent steel cabinet. The limited warranty is 10 years on the compressor.\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eThis size matches most Greater Montreal bungalows and cottages that already have ductwork, and it is also the one replaced most often. An undersized unit runs non-stop during heat waves; an oversized one cools fast but dehumidifies poorly. We run the numbers before proposing anything.\u003c\/p\u003e\n\u003ch3\u003eTechnical data worth knowing\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 14.3 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 71 dBA. It needs a 208\/230 V single-phase circuit with a 16.2 A minimum circuit ampacity and a 25 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 3 lb (1.36 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 29 1\/4 x 29 1\/4 in at the base and 39 1\/2 in high, with an operating weight of 165 lb, 15 lb more than the 2-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eR-454B has a much lower global warming potential than the R-410A it replaces. Like any A2L refrigerant, it requires a compatible indoor section and an installation that follows the manufacturer's instructions.\u003c\/p\u003e\n\u003cp\u003eNote: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.\u003c\/p\u003e\n\u003cp\u003eOther York series offered at 2.5 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc3-lx-2-5-tonnes-30000-btu-r454b\"\u003eYork YC3 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2f-lx-2-5-tonnes-30000-btu-r410a\"\u003eYork YC2F LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-ycg-lx-2-5-tonnes-30000-btu-r410a\"\u003eYork YCG LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 3\/4 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eThe next step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YC430E2S11: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395071340836,"sku":"YC430E2S11","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC4_YC430E2S11_00_2_5_TONNES_30000_BTU_R454B_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yc6-lx-2-tonnes-24000-btu-r454b","title":"YORK YC6 LX Central Air Conditioner | 2 Tons - 24000 BTU - R454B","description":"\u003ch2\u003eThe 2-ton YC6: cooling a small home that already has ductwork\u003c\/h2\u003e\n\u003cp\u003eThe YC624E2S11 is the 2-ton (24,000 BTU\/h) condensing unit of the York YC6 (LX) series, between the 1.5-ton and 3-ton sizes of the same series. It runs on R-454B, with a two-stage scroll compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC6 is the two-stage series of York's R-454B LX range, up to 18 SEER2 depending on size and match. From 2 to 5 tons, its two-stage scroll compressor spends most of its time at reduced capacity, for drier air and quieter operation, and only goes to full capacity when needed. The 1.5-ton size uses a single-stage rotary compressor instead.\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eIt is the typical size for a condo or a townhouse where the electrical panel is already well filled and outdoor space is tight. A well-chosen size dehumidifies better: an oversized unit cools quickly, shuts off right away and leaves the house cool but clammy. On the electrical side, a 20 A maximum breaker is enough, which often avoids major panel work.\u003c\/p\u003e\n\u003ch3\u003eTechnical data worth knowing\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 16 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 72 dBA. Electrical: 208\/230 V single-phase circuit, 13.7 A minimum ampacity, 20 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 3 lb (1.36 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 29 1\/4 x 29 1\/4 in at the base and 30 in high, with an operating weight of 150 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eR-454B replaces R-410A in new air conditioners sold in Canada. It is an A2L-class refrigerant: we install it with an indoor section approved for it, following the manufacturer's requirements.\u003c\/p\u003e\n\u003cp\u003eNote: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.\u003c\/p\u003e\n\u003cp\u003eOther York series offered at 2 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc4-lx-2-tonnes-24000-btu-r454b\"\u003eYork YC4 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc3-lx-2-tonnes-24000-btu-r454b\"\u003eYork YC3 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxt-affinity-2-tonnes-24000-btu-r410a\"\u003eYork YXT Affinity\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 3\/4 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eWe install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTorn between two sizes or two series? Ask for a free estimate: we compare the options for your home and give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395072028964,"sku":"YC624E2S11","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC6_YC624E2S11_00_2_TONNES_24000_BTU_R454B_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yc2d-lx-2-tonnes-24000-btu-r410a","title":"YORK YC2D LX Central Air Conditioner | 2 Tons - 24000 BTU - R410A","description":"\u003ch2\u003eA small York size to add central air without overloading the panel\u003c\/h2\u003e\n\u003cp\u003eThe YC2D24SB21S is the 2-ton (24,000 BTU\/h) condensing unit of the York YC2D (LX) series, between the 1.5-ton and 2.5-ton sizes of the same series. It runs on R-410A, with a single-stage rotary compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC2D belongs to York's LX range, here in R-410A and on clearance. It is the range's basic model, rated 13.4 SEER2 by York, with a single-stage compressor (rotary at 1.5 and 2 tons, scroll in the other sizes), G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 (at least 500 h). The limited warranty is 10 years on the compressor, and the parts warranty goes from 5 to 10 years with registration.\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eIt is often chosen to add air conditioning to a small house heated by an electric furnace: a coil is added on the furnace, and the condensing unit does the rest outside. A well-chosen size dehumidifies better: an oversized unit cools quickly, shuts off right away and leaves the house cool but clammy. On the electrical side, a 15 A maximum breaker is enough, which often avoids major panel work.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eYork publishes a range of 13.4 to 15 SEER2 for this size, depending on the matched indoor section; the condensing unit alone has no certified rating. The spec sheet lists a sound power of 74 dBA. It needs a 208\/230 V single-phase circuit with a 11.3 A minimum circuit ampacity and a 15 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 3.25 lb (1.47 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 24 x 24 in at the base and 33 1\/4 in high, with an operating weight of 135 lb, 15 lb more than the 1.5-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eThis model runs on R-410A, a refrigerant that manufacturers are gradually replacing with R-454B and R-32 in their new series. It is offered while our suppliers' stock lasts, and it suits replacing an R-410A condensing unit on a compatible coil.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eSame size, other series: \u003ca href=\"\/en\/products\/climatiseur-central-york-yxv-affinity-2-tonnes-24000-btu-r410a\"\u003eYork YXV Affinity\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2f-lx-2-tonnes-24000-btu-r410a\"\u003eYork YC2F LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxt-affinity-2-tonnes-24000-btu-r410a\"\u003eYork YXT Affinity\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 3\/4 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTorn between two sizes or two series? Ask for a free estimate: we compare the options for your home and give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395073601828,"sku":"YC2D24SB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC2D_YC2D24SB21S_00_2_TONNES_24000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692129"},{"product_id":"climatiseur-central-york-yc2e-lx-2-tonnes-24000-btu-r410a","title":"YORK YC2E LX Central Air Conditioner | 2 Tons - 24000 BTU - R410A","description":"\u003ch2\u003e2 tons of central air for a condo, a townhouse or a small bungalow\u003c\/h2\u003e\n\u003cp\u003eAt 24,000 BTU\/h, the YC2E24SB21S is the 2-ton size of the York YC2E (LX) series, between the 1.5-ton and 2.5-ton sizes of the same series. It is the outdoor unit of an R-410A central air conditioner, fitted with a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC2E is the 14.3 SEER2 version of York's R-410A LX range, offered on clearance while stock lasts. Same single-stage scroll compressor and same cabinet of G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 as the YC2D, with better efficiency. With the approved low-ambient kits it can cool down to 20°F (-7°C).\u003c\/p\u003e\n\u003ch3\u003eThe right size for your home\u003c\/h3\u003e\n\u003cp\u003eThis size is aimed at condos, townhouses and modest bungalows that already have ductwork. A bigger unit would short-cycle there. In a small home, cycle length is what matters: the longer the cycles, the drier the air and the more real the comfort. On the electrical side, a 25 A maximum breaker is enough, which often avoids major panel work.\u003c\/p\u003e\n\u003ch3\u003eTechnical data worth knowing\u003c\/h3\u003e\n\u003cp\u003eYork publishes a range of 14.3 to 16.5 SEER2 for this size, depending on the matched indoor section; the condensing unit alone has no certified rating. The spec sheet lists a sound power of 73 dBA. Electrical: 208\/230 V single-phase circuit, 15.1 A minimum ampacity, 25 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 3.19 lb (1.45 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 29 1\/4 x 29 1\/4 in at the base and 30 in high, with an operating weight of 150 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eManufacturers are gradually replacing R-410A with R-454B and R-32 in their new series, so this model is offered until stock runs out. It is most attractive if your current R-410A coil is recent and compatible.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eOther York series offered at 2 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-2-tonnes-24000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2f-lx-2-tonnes-24000-btu-r410a\"\u003eYork YC2F LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxt-affinity-2-tonnes-24000-btu-r410a\"\u003eYork YXT Affinity\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eA Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 3\/4 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm whether 2 tons is the right size, check the panel and the ducts, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395075600676,"sku":"YC2E24SB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC2E_YC2E24SB21S_00_2_TONNES_24000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692128"},{"product_id":"climatiseur-central-york-ycg-lx-3-tonnes-36000-btu-r410a","title":"YORK YCG LX Central Air Conditioner | 3 Tons - 36000 BTU - R410A","description":"\u003ch2\u003eThe 3-ton YCG for a bungalow or cottage with ductwork\u003c\/h2\u003e\n\u003cp\u003eThe YCG36B21S is the 3-ton (36,000 BTU\/h) condensing unit of the York YCG (LX) series, between the 2.5-ton and 3.5-ton sizes of the same series. It runs on R-410A, with a single-stage scroll compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YCG is a York LX R-410A condensing unit, offered from 2 to 5 tons on clearance. Its paint is tested for at least 750 hours of salt spray, more than the other LX models. The limited warranty is 10 years on the compressor, with 10 years on parts if the unit is registered.\u003c\/p\u003e\n\u003ch3\u003eThe right size for your home\u003c\/h3\u003e\n\u003cp\u003eFor a mid-size single-family house with an electric furnace or a fan coil in the basement, it is often the balance point between comfort and consumption. Before confirming the size, we look at the insulation, the orientation of the windows and the capacity of the ducts.\u003c\/p\u003e\n\u003ch3\u003eTechnical data worth knowing\u003c\/h3\u003e\n\u003cp\u003eThe spec sheet lists a sound power of 72 dBA. It needs a 208\/230 V single-phase circuit with a 22.0 A minimum circuit ampacity and a 35 A maximum time-delay fuse or breaker. The unit ships with a factory charge of 4.56 lb (2.07 kg) of R-410A, which our technicians adjust to the actual piping length.\u003c\/p\u003e\n\u003cp\u003eThe cabinet measures 35 1\/4 x 31 3\/4 in at the base and 36 1\/4 in high, with an operating weight of 175 lb, 10 lb more than the 2.5-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eManufacturers are gradually replacing R-410A with R-454B and R-32 in their new series, so this model is offered until stock runs out. It is most attractive if your current R-410A coil is recent and compatible.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eSame size, other series: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2f-lx-3-tonnes-36000-btu-r410a\"\u003eYork YC2F LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-3-tonnes-36000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-3-tonnes-36000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 3\/4 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YCG36B21S: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395086971172,"sku":"YCG36B21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YCG_YCG36B21S_00_3_TONNES_36000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yc3-lx-3-tonnes-36000-btu-r454b","title":"YORK YC3 LX Central Air Conditioner | 3 Tons - 36000 BTU - R454B","description":"\u003ch2\u003e3 tons, the size that suits many Greater Montreal homes\u003c\/h2\u003e\n\u003cp\u003eThe YC336E2S11 is the 3-ton (36,000 BTU\/h) condensing unit of the York YC3 (LX) series, between the 2.5-ton and 3.5-ton sizes of the same series. It runs on R-454B, with a single-stage scroll compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC3 is the basic model of York's R-454B LX range. Single-stage compressor, rotary at 1.5 and 2 tons and scroll in the other sizes, G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 (at least 500 h), up to 80 ft of piping: a simple, durable build. With the approved low-ambient kits it can cool down to 20°F (-7°C), useful when a room overheats in spring.\u003c\/p\u003e\n\u003ch3\u003eWhich homes does it suit?\u003c\/h3\u003e\n\u003cp\u003eThis size matches most Greater Montreal bungalows and cottages that already have ductwork, and it is also the one replaced most often. An undersized unit runs non-stop during heat waves; an oversized one cools fast but dehumidifies poorly. We run the numbers before proposing anything.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 13.4 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 74 dBA. It needs a 208\/230 V single-phase circuit with a 18.2 A minimum circuit ampacity and a 30 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 2.88 lb (1.30 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 24 x 24 in at the base and 36 1\/4 in high, with an operating weight of 140 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eRunning on R-454B, this condensing unit meets the Canadian rules now in force for new air conditioners. R-454B is mildly flammable (A2L class): the indoor section must be approved for it, and the installation follows the manufacturer's instructions.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eTo compare, still at 3 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc4-lx-3-tonnes-36000-btu-r454b\"\u003eYork YC4 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc6-lx-3-tonnes-36000-btu-r454b\"\u003eYork YC6 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-3-tonnes-36000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eA Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 3\/4 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm whether 3 tons is the right size, check the panel and the ducts, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395087102244,"sku":"YC336E2S11","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC3_YC336E2S11_00_3_TONNES_36000_BTU_R454B_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692127"},{"product_id":"climatiseur-central-york-yc4-lx-3-tonnes-36000-btu-r454b","title":"YORK YC4 LX Central Air Conditioner | 3 Tons - 36000 BTU - R454B","description":"\u003ch2\u003eCooling a whole mid-size house with a 3-ton York\u003c\/h2\u003e\n\u003cp\u003eA 3-ton size, or 36,000 BTU\/h: the YC436E2S11 belongs to the York YC4 (LX) series, between the 2.5-ton and 3.5-ton sizes of the same series. This R-454B condensing unit uses a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC4 moves York's R-454B LX range one step up in efficiency, up to 16 SEER2 depending on size and match. It comes from 2 to 5 tons, with a single-stage scroll compressor and the range's G90-equivalent steel cabinet. The limited warranty is 10 years on the compressor.\u003c\/p\u003e\n\u003ch3\u003eWhich homes does it suit?\u003c\/h3\u003e\n\u003cp\u003eYou find it in many cottages built from the 1980s to the 2000s, where an old condensing unit of the same size is reaching the end of its life. Before confirming the size, we look at the insulation, the orientation of the windows and the capacity of the ducts.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 14.3 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 72 dBA. It needs a 208\/230 V single-phase circuit with a 19.0 A minimum circuit ampacity and a 30 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 3.12 lb (1.42 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 35 1\/4 x 31 3\/4 in at the base and 33 1\/4 in high, with an operating weight of 185 lb, 20 lb more than the 2.5-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eR-454B replaces R-410A in new air conditioners sold in Canada. It is an A2L-class refrigerant: we install it with an indoor section approved for it, following the manufacturer's requirements.\u003c\/p\u003e\n\u003cp\u003eThis condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.\u003c\/p\u003e\n\u003cp\u003eTo compare, still at 3 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc6-lx-3-tonnes-36000-btu-r454b\"\u003eYork YC6 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc3-lx-3-tonnes-36000-btu-r454b\"\u003eYork YC3 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-3-tonnes-36000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eA Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 3\/4 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eThe next step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTorn between two sizes or two series? Ask for a free estimate: we compare the options for your home and give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395087135012,"sku":"YC436E2S11","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC4_YC436E2S11_00_3_TONNES_36000_BTU_R454B_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yc6-lx-3-tonnes-36000-btu-r454b","title":"YORK YC6 LX Central Air Conditioner | 3 Tons - 36000 BTU - R454B","description":"\u003ch2\u003e3 tons, the size that suits many Greater Montreal homes\u003c\/h2\u003e\n\u003cp\u003eA 3-ton size, or 36,000 BTU\/h: the YC636E2S11 belongs to the York YC6 (LX) series, between the 2-ton and 4-ton sizes of the same series. This R-454B condensing unit uses a two-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC6 is the two-stage series of York's R-454B LX range, up to 18 SEER2 depending on size and match. From 2 to 5 tons, its two-stage scroll compressor spends most of its time at reduced capacity, for drier air and quieter operation, and only goes to full capacity when needed. The 1.5-ton size uses a single-stage rotary compressor instead.\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eYou find it in many cottages built from the 1980s to the 2000s, where an old condensing unit of the same size is reaching the end of its life. Before confirming the size, we look at the insulation, the orientation of the windows and the capacity of the ducts.\u003c\/p\u003e\n\u003ch3\u003eTechnical data worth knowing\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 16 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 72 dBA. Electrical: 208\/230 V single-phase circuit, 19.2 A minimum ampacity, 30 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 3.5 lb (1.59 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 38 x 34 1\/4 in at the base and 36 1\/4 in high, with an operating weight of 235 lb, 85 lb more than the 2-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eRunning on R-454B, this condensing unit meets the Canadian rules now in force for new air conditioners. R-454B is mildly flammable (A2L class): the indoor section must be approved for it, and the installation follows the manufacturer's instructions.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eSame size, other series: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc4-lx-3-tonnes-36000-btu-r454b\"\u003eYork YC4 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc3-lx-3-tonnes-36000-btu-r454b\"\u003eYork YC3 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2f-lx-3-tonnes-36000-btu-r410a\"\u003eYork YC2F LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 3\/4 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eWe install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eThe next step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTorn between two sizes or two series? Ask for a free estimate: we compare the options for your home and give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395088445732,"sku":"YC636E2S11","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC6_YC636E2S11_00_3_TONNES_36000_BTU_R454B_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yc2d-lx-2-5-tonnes-30000-btu-r410a","title":"YORK YC2D LX Central Air Conditioner | 2.5 Tons - 30000 BTU - R410A","description":"\u003ch2\u003eCooling a whole mid-size house with a 2.5-ton York\u003c\/h2\u003e\n\u003cp\u003eA 2.5-ton size, or 30,000 BTU\/h: the YC2D30SB21S belongs to the York YC2D (LX) series, between the 2-ton and 3-ton sizes of the same series. This R-410A condensing unit uses a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC2D belongs to York's LX range, here in R-410A and on clearance. It is the range's basic model, rated 13.4 SEER2 by York, with a single-stage compressor (rotary at 1.5 and 2 tons, scroll in the other sizes), G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 (at least 500 h). The limited warranty is 10 years on the compressor, and the parts warranty goes from 5 to 10 years with registration.\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eThis size matches most Greater Montreal bungalows and cottages that already have ductwork, and it is also the one replaced most often. An undersized unit runs non-stop during heat waves; an oversized one cools fast but dehumidifies poorly. We run the numbers before proposing anything.\u003c\/p\u003e\n\u003ch3\u003eWhat the manufacturer's spec sheet says\u003c\/h3\u003e\n\u003cp\u003eYork publishes a range of 13.4 to 14.75 SEER2 for this size, depending on the matched indoor section; the condensing unit alone has no certified rating. The spec sheet lists a sound power of 73 dBA. Electrical: 208\/230 V single-phase circuit, 15.3 A minimum ampacity, 25 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 3.25 lb (1.47 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 24 x 24 in at the base and 33 1\/4 in high, with an operating weight of 130 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eThis model runs on R-410A, a refrigerant that manufacturers are gradually replacing with R-454B and R-32 in their new series. It is offered while our suppliers' stock lasts, and it suits replacing an R-410A condensing unit on a compatible coil.\u003c\/p\u003e\n\u003cp\u003eThis condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.\u003c\/p\u003e\n\u003cp\u003eTo compare, still at 2.5 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-ycg-lx-2-5-tonnes-30000-btu-r410a\"\u003eYork YCG LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2f-lx-2-5-tonnes-30000-btu-r410a\"\u003eYork YC2F LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-2-5-tonnes-30000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 3\/4 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YC2D30SB21S: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395091263780,"sku":"YC2D30SB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC2D_YC2D30SB21S_00_2_5_TONNES_30000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692129"},{"product_id":"climatiseur-central-york-yc2e-lx-2-5-tonnes-30000-btu-r410a","title":"YORK YC2E LX Central Air Conditioner | 2.5 Tons - 30000 BTU - R410A","description":"\u003ch2\u003eThe 2.5-ton YC2E for a bungalow or cottage with ductwork\u003c\/h2\u003e\n\u003cp\u003eThe YC2E30SB21S is the 2.5-ton (30,000 BTU\/h) condensing unit of the York YC2E (LX) series, between the 2-ton and 3-ton sizes of the same series. It runs on R-410A, with a single-stage scroll compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC2E is the 14.3 SEER2 version of York's R-410A LX range, offered on clearance while stock lasts. Same single-stage scroll compressor and same cabinet of G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 as the YC2D, with better efficiency. With the approved low-ambient kits it can cool down to 20°F (-7°C).\u003c\/p\u003e\n\u003ch3\u003eThe right size for your home\u003c\/h3\u003e\n\u003cp\u003eThis size matches most Greater Montreal bungalows and cottages that already have ductwork, and it is also the one replaced most often. An undersized unit runs non-stop during heat waves; an oversized one cools fast but dehumidifies poorly. We run the numbers before proposing anything.\u003c\/p\u003e\n\u003ch3\u003eWhat the manufacturer's spec sheet says\u003c\/h3\u003e\n\u003cp\u003eYork publishes a range of 14.3 to 16 SEER2 for this size, depending on the matched indoor section; the condensing unit alone has no certified rating. The spec sheet lists a sound power of 73 dBA. Electrical: 208\/230 V single-phase circuit, 15.3 A minimum ampacity, 25 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 3.81 lb (1.73 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 29 1\/4 x 29 1\/4 in at the base and 36 1\/4 in high, with an operating weight of 165 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eManufacturers are gradually replacing R-410A with R-454B and R-32 in their new series, so this model is offered until stock runs out. It is most attractive if your current R-410A coil is recent and compatible.\u003c\/p\u003e\n\u003cp\u003eThis condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.\u003c\/p\u003e\n\u003cp\u003eTo compare, still at 2.5 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-ycg-lx-2-5-tonnes-30000-btu-r410a\"\u003eYork YCG LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-2-5-tonnes-30000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2f-lx-2-5-tonnes-30000-btu-r410a\"\u003eYork YC2F LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 3\/4 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTorn between two sizes or two series? Ask for a free estimate: we compare the options for your home and give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395092803876,"sku":"YC2E30SB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC2E_YC2E30SB21S_00_2_5_TONNES_30000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692128"},{"product_id":"climatiseur-central-york-ycg-lx-3-5-tonnes-42000-btu-r410a","title":"YORK YCG LX Central Air Conditioner | 3.5 Tons - 42000 BTU - R410A","description":"\u003ch2\u003eA 3.5-ton York for a large house on a single duct system\u003c\/h2\u003e\n\u003cp\u003eAt 42,000 BTU\/h, the YCG42B21S is the 3.5-ton size of the York YCG (LX) series, between the 3-ton and 4-ton sizes of the same series. It is the outdoor unit of an R-410A central air conditioner, fitted with a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YCG is a York LX R-410A condensing unit, offered from 2 to 5 tons on clearance. Its paint is tested for at least 750 hours of salt spray, more than the other LX models. The limited warranty is 10 years on the compressor, with 10 years on parts if the unit is registered.\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eIt is chosen for recent open-plan houses, extensions and homes whose windows get a lot of afternoon sun. At this size, duct capacity matters as much as the unit's: undersized ducts make the air noisy at the grilles and reduce efficiency.\u003c\/p\u003e\n\u003ch3\u003eTechnical data worth knowing\u003c\/h3\u003e\n\u003cp\u003eThe spec sheet lists a sound power of 73 dBA. Electrical: 208\/230 V single-phase circuit, 23.6 A minimum ampacity, 40 A maximum time-delay fuse or breaker. The unit ships with a factory charge of 6.38 lb (2.89 kg) of R-410A, which our technicians adjust to the actual piping length.\u003c\/p\u003e\n\u003cp\u003eThe cabinet measures 38 x 34 1\/4 in at the base and 39 1\/2 in high, with an operating weight of 220 lb, 45 lb more than the 3-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eThis model runs on R-410A, a refrigerant that manufacturers are gradually replacing with R-454B and R-32 in their new series. It is offered while our suppliers' stock lasts, and it suits replacing an R-410A condensing unit on a compatible coil.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eOther York series offered at 3.5 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-3-5-tonnes-42000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-3-5-tonnes-42000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc3-lx-3-5-tonnes-42000-btu-r454b\"\u003eYork YC3 LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 7\/8 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eThe next step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm whether 3.5 tons is the right size, check the panel and the ducts, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395097784612,"sku":"YCG42B21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YCG_YCG42B21S_00_3_5_TONNES_42000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yc4-lx-3-5-tonnes-42000-btu-r454b","title":"YORK YC4 LX Central Air Conditioner | 3.5 Tons - 42000 BTU - R454B","description":"\u003ch2\u003eThe 3.5-ton YC4, when the upper floor needs more cooling\u003c\/h2\u003e\n\u003cp\u003eAt 42,000 BTU\/h, the YC442E2S11 is the 3.5-ton size of the York YC4 (LX) series, between the 3-ton and 4-ton sizes of the same series. It is the outdoor unit of an R-454B central air conditioner, fitted with a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC4 moves York's R-454B LX range one step up in efficiency, up to 16 SEER2 depending on size and match. It comes from 2 to 5 tons, with a single-stage scroll compressor and the range's G90-equivalent steel cabinet. The limited warranty is 10 years on the compressor.\u003c\/p\u003e\n\u003ch3\u003eThe right size for your home\u003c\/h3\u003e\n\u003cp\u003eThis size targets large multi-storey houses, open-plan layouts and heavily glazed homes, where a smaller unit struggles to keep the top floor comfortable. We always check the furnace airflow and the size of the return ducts before recommending this size.\u003c\/p\u003e\n\u003ch3\u003eTechnical data worth knowing\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 14.3 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 73 dBA. Electrical: 208\/230 V single-phase circuit, 18.9 A minimum ampacity, 30 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 3.38 lb (1.53 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 38 x 34 1\/4 in at the base and 36 1\/4 in high, with an operating weight of 230 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eR-454B has a much lower global warming potential than the R-410A it replaces. Like any A2L refrigerant, it requires a compatible indoor section and an installation that follows the manufacturer's instructions.\u003c\/p\u003e\n\u003cp\u003eThis condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.\u003c\/p\u003e\n\u003cp\u003eSame size, other series: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc3-lx-3-5-tonnes-42000-btu-r454b\"\u003eYork YC3 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-ycg-lx-3-5-tonnes-42000-btu-r410a\"\u003eYork YCG LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-3-5-tonnes-42000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eA Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 7\/8 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YC442E2S11: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395099488548,"sku":"YC442E2S11","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC4_YC442E2S11_00_3_5_TONNES_42000_BTU_R454B_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692127"},{"product_id":"climatiseur-central-york-yc3-lx-3-5-tonnes-42000-btu-r454b","title":"YORK YC3 LX Central Air Conditioner | 3.5 Tons - 42000 BTU - R454B","description":"\u003ch2\u003eA 3.5-ton York for a large house on a single duct system\u003c\/h2\u003e\n\u003cp\u003eAt 42,000 BTU\/h, the YC342E2S11 is the 3.5-ton size of the York YC3 (LX) series, between the 3-ton and 4-ton sizes of the same series. It is the outdoor unit of an R-454B central air conditioner, fitted with a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC3 is the basic model of York's R-454B LX range. Single-stage compressor, rotary at 1.5 and 2 tons and scroll in the other sizes, G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 (at least 500 h), up to 80 ft of piping: a simple, durable build. With the approved low-ambient kits it can cool down to 20°F (-7°C), useful when a room overheats in spring.\u003c\/p\u003e\n\u003ch3\u003eThe right size for your home\u003c\/h3\u003e\n\u003cp\u003eA large house with a single furnace and a single duct system often needs this size, especially when the bedrooms are upstairs and face south or west. At this size, duct capacity matters as much as the unit's: undersized ducts make the air noisy at the grilles and reduce efficiency.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 13.4 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 76 dBA. Electrical: 208\/230 V single-phase circuit, 19.2 A minimum ampacity, 30 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 2.94 lb (1.33 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 29 1\/4 x 29 1\/4 in at the base and 36 1\/4 in high, with an operating weight of 195 lb, 55 lb more than the 3-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eR-454B replaces R-410A in new air conditioners sold in Canada. It is an A2L-class refrigerant: we install it with an indoor section approved for it, following the manufacturer's requirements.\u003c\/p\u003e\n\u003cp\u003eNote: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.\u003c\/p\u003e\n\u003cp\u003eTo compare, still at 3.5 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc4-lx-3-5-tonnes-42000-btu-r454b\"\u003eYork YC4 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-ycg-lx-3-5-tonnes-42000-btu-r410a\"\u003eYork YCG LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-3-5-tonnes-42000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 7\/8 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm whether 3.5 tons is the right size, check the panel and the ducts, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395099554084,"sku":"YC342E2S11","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC3_YC342E2S11_00_3_5_TONNES_42000_BTU_R454B_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692127"},{"product_id":"climatiseur-central-york-yc6-lx-4-tonnes-48000-btu-r454b","title":"YORK YC6 LX Central Air Conditioner | 4 Tons - 48000 BTU - R454B","description":"\u003ch2\u003eA 4-ton York for a large house on a single duct system\u003c\/h2\u003e\n\u003cp\u003eAt 48,000 BTU\/h, the YC648E2S11 is the 4-ton size of the York YC6 (LX) series, between the 3-ton and 5-ton sizes of the same series. It is the outdoor unit of an R-454B central air conditioner, fitted with a two-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC6 is the two-stage series of York's R-454B LX range, up to 18 SEER2 depending on size and match. From 2 to 5 tons, its two-stage scroll compressor spends most of its time at reduced capacity, for drier air and quieter operation, and only goes to full capacity when needed. The 1.5-ton size uses a single-stage rotary compressor instead.\u003c\/p\u003e\n\u003ch3\u003eWhich homes does it suit?\u003c\/h3\u003e\n\u003cp\u003eThis size targets large multi-storey houses, open-plan layouts and heavily glazed homes, where a smaller unit struggles to keep the top floor comfortable. At this size, duct capacity matters as much as the unit's: undersized ducts make the air noisy at the grilles and reduce efficiency.\u003c\/p\u003e\n\u003ch3\u003eTechnical data worth knowing\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 16 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 74 dBA. It needs a 208\/230 V single-phase circuit with a 27.3 A minimum circuit ampacity and a 45 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 4.69 lb (2.13 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 38 x 34 1\/4 in at the base and 39 1\/2 in high, with an operating weight of 250 lb, 15 lb more than the 3-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eRunning on R-454B, this condensing unit meets the Canadian rules now in force for new air conditioners. R-454B is mildly flammable (A2L class): the indoor section must be approved for it, and the installation follows the manufacturer's instructions.\u003c\/p\u003e\n\u003cp\u003eThis condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.\u003c\/p\u003e\n\u003cp\u003eTo compare, still at 4 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc4-lx-4-tonnes-48000-btu-r454b\"\u003eYork YC4 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc3-lx-4-tonnes-48000-btu-r454b\"\u003eYork YC3 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxt-affinity-4-tonnes-48000-btu-r410a\"\u003eYork YXT Affinity\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 7\/8 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eWe install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eThe next step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm whether 4 tons is the right size, check the panel and the ducts, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395099717924,"sku":"YC648E2S11","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC6_YC648E2S11_00_4_TONNES_48000_BTU_R454B_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yc2d-lx-3-tonnes-36000-btu-r410a","title":"YORK YC2D LX Central Air Conditioner | 3 Tons - 36000 BTU - R410A","description":"\u003ch2\u003e3 tons, the size that suits many Greater Montreal homes\u003c\/h2\u003e\n\u003cp\u003eAt 36,000 BTU\/h, the YC2D36SB21S is the 3-ton size of the York YC2D (LX) series, between the 2.5-ton and 3.5-ton sizes of the same series. It is the outdoor unit of an R-410A central air conditioner, fitted with a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC2D belongs to York's LX range, here in R-410A and on clearance. It is the range's basic model, rated 13.4 SEER2 by York, with a single-stage compressor (rotary at 1.5 and 2 tons, scroll in the other sizes), G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 (at least 500 h). The limited warranty is 10 years on the compressor, and the parts warranty goes from 5 to 10 years with registration.\u003c\/p\u003e\n\u003ch3\u003eWhich homes does it suit?\u003c\/h3\u003e\n\u003cp\u003eYou find it in many cottages built from the 1980s to the 2000s, where an old condensing unit of the same size is reaching the end of its life. Before confirming the size, we look at the insulation, the orientation of the windows and the capacity of the ducts.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eYork publishes a range of 13.4 to 14.75 SEER2 for this size, depending on the matched indoor section; the condensing unit alone has no certified rating. The spec sheet lists a sound power of 74 dBA. Electrical: 208\/230 V single-phase circuit, 19.6 A minimum ampacity, 30 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 4.19 lb (1.90 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 29 1\/4 x 29 1\/4 in at the base and 30 in high, with an operating weight of 150 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eRunning on R-410A, this condensing unit is part of the stock still available: manufacturers are gradually moving to R-454B and R-32 in their new series. It is a good option to replace an R-410A unit while keeping a coil in good condition.\u003c\/p\u003e\n\u003cp\u003eThis condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.\u003c\/p\u003e\n\u003cp\u003eOther York series offered at 3 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-3-tonnes-36000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxv-affinity-3-tonnes-36000-btu-r410a\"\u003eYork YXV Affinity\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2f-lx-3-tonnes-36000-btu-r410a\"\u003eYork YC2F LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eA Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 3\/4 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YC2D36SB21S: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395101159716,"sku":"YC2D36SB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC2D_YC2D36SB21S_00_3_TONNES_36000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692128"},{"product_id":"climatiseur-central-york-yc2e-lx-3-tonnes-36000-btu-r410a","title":"YORK YC2E LX Central Air Conditioner | 3 Tons - 36000 BTU - R410A","description":"\u003ch2\u003eThe 3-ton YC2E for a bungalow or cottage with ductwork\u003c\/h2\u003e\n\u003cp\u003eA 3-ton size, or 36,000 BTU\/h: the YC2E36SB21S belongs to the York YC2E (LX) series, between the 2.5-ton and 3.5-ton sizes of the same series. This R-410A condensing unit uses a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC2E is the 14.3 SEER2 version of York's R-410A LX range, offered on clearance while stock lasts. Same single-stage scroll compressor and same cabinet of G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 as the YC2D, with better efficiency. With the approved low-ambient kits it can cool down to 20°F (-7°C).\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eFor a mid-size single-family house with an electric furnace or a fan coil in the basement, it is often the balance point between comfort and consumption. Before confirming the size, we look at the insulation, the orientation of the windows and the capacity of the ducts.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eYork publishes a range of 14.3 to 15.5 SEER2 for this size, depending on the matched indoor section; the condensing unit alone has no certified rating. The spec sheet lists a sound power of 73 dBA. It needs a 208\/230 V single-phase circuit with a 17.6 A minimum circuit ampacity and a 30 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 4.31 lb (1.96 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 35 1\/4 x 31 3\/4 in at the base and 33 1\/4 in high, with an operating weight of 185 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eThis model runs on R-410A, a refrigerant that manufacturers are gradually replacing with R-454B and R-32 in their new series. It is offered while our suppliers' stock lasts, and it suits replacing an R-410A condensing unit on a compatible coil.\u003c\/p\u003e\n\u003cp\u003eNote: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.\u003c\/p\u003e\n\u003cp\u003eTo compare, still at 3 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-ycg-lx-3-tonnes-36000-btu-r410a\"\u003eYork YCG LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-3-tonnes-36000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxv-affinity-3-tonnes-36000-btu-r410a\"\u003eYork YXV Affinity\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 3\/4 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTorn between two sizes or two series? Ask for a free estimate: we compare the options for your home and give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395103944996,"sku":"YC2E36SB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC2E_YC2E36SB21S_00_3_TONNES_36000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692129"},{"product_id":"climatiseur-central-york-ycg-lx-4-tonnes-48000-btu-r410a","title":"YORK YCG LX Central Air Conditioner | 4 Tons - 48000 BTU - R410A","description":"\u003ch2\u003eThe 4-ton YCG, when the upper floor needs more cooling\u003c\/h2\u003e\n\u003cp\u003eA 4-ton size, or 48,000 BTU\/h: the YCG48B21S belongs to the York YCG (LX) series, between the 3.5-ton and 5-ton sizes of the same series. This R-410A condensing unit uses a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YCG is a York LX R-410A condensing unit, offered from 2 to 5 tons on clearance. Its paint is tested for at least 750 hours of salt spray, more than the other LX models. The limited warranty is 10 years on the compressor, with 10 years on parts if the unit is registered.\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eA large house with a single furnace and a single duct system often needs this size, especially when the bedrooms are upstairs and face south or west. We always check the furnace airflow and the size of the return ducts before recommending this size.\u003c\/p\u003e\n\u003ch3\u003eWhat the manufacturer's spec sheet says\u003c\/h3\u003e\n\u003cp\u003eThe spec sheet lists a sound power of 74 dBA. Electrical: 208\/230 V single-phase circuit, 25.9 A minimum ampacity, 40 A maximum time-delay fuse or breaker. The unit ships with a factory charge of 6.69 lb (3.03 kg) of R-410A, which our technicians adjust to the actual piping length.\u003c\/p\u003e\n\u003cp\u003eThe cabinet measures 38 x 34 1\/4 in at the base and 39 1\/2 in high, with an operating weight of 220 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eRunning on R-410A, this condensing unit is part of the stock still available: manufacturers are gradually moving to R-454B and R-32 in their new series. It is a good option to replace an R-410A unit while keeping a coil in good condition.\u003c\/p\u003e\n\u003cp\u003eNote: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.\u003c\/p\u003e\n\u003cp\u003eTo compare, still at 4 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yxv-affinity-4-tonnes-48000-btu-r410a\"\u003eYork YXV Affinity\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yce-lx-4-tonnes-48000-btu-r410a\"\u003eYork YCE LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-4-tonnes-48000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 7\/8 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eThe next step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YCG48B21S: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395108237604,"sku":"YCG48B21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YCG_YCG48B21S_00_4_TONNES_48000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yc4-lx-4-tonnes-48000-btu-r454b","title":"YORK YC4 LX Central Air Conditioner | 4 Tons - 48000 BTU - R454B","description":"\u003ch2\u003eThe 4-ton YC4, when the upper floor needs more cooling\u003c\/h2\u003e\n\u003cp\u003eAt 48,000 BTU\/h, the YC448E2S11 is the 4-ton size of the York YC4 (LX) series, between the 3.5-ton and 5-ton sizes of the same series. It is the outdoor unit of an R-454B central air conditioner, fitted with a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC4 moves York's R-454B LX range one step up in efficiency, up to 16 SEER2 depending on size and match. It comes from 2 to 5 tons, with a single-stage scroll compressor and the range's G90-equivalent steel cabinet. The limited warranty is 10 years on the compressor.\u003c\/p\u003e\n\u003ch3\u003eWhich homes does it suit?\u003c\/h3\u003e\n\u003cp\u003eThis size targets large multi-storey houses, open-plan layouts and heavily glazed homes, where a smaller unit struggles to keep the top floor comfortable. We always check the furnace airflow and the size of the return ducts before recommending this size.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 14.3 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 75 dBA. It needs a 208\/230 V single-phase circuit with a 29.1 A minimum circuit ampacity and a 50 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 3.69 lb (1.67 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 35 1\/4 x 31 3\/4 in at the base and 36 1\/4 in high, with an operating weight of 215 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eR-454B has a much lower global warming potential than the R-410A it replaces. Like any A2L refrigerant, it requires a compatible indoor section and an installation that follows the manufacturer's instructions.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eTo compare, still at 4 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc6-lx-4-tonnes-48000-btu-r454b\"\u003eYork YC6 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc3-lx-4-tonnes-48000-btu-r454b\"\u003eYork YC3 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxv-affinity-4-tonnes-48000-btu-r410a\"\u003eYork YXV Affinity\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 7\/8 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm whether 4 tons is the right size, check the panel and the ducts, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395109974308,"sku":"YC448E2S11","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC4_YC448E2S11_00_4_TONNES_48000_BTU_R454B_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692127"},{"product_id":"climatiseur-central-york-yc3-lx-4-tonnes-48000-btu-r454b","title":"YORK YC3 LX Central Air Conditioner | 4 Tons - 48000 BTU - R454B","description":"\u003ch2\u003eA 4-ton York for a large house on a single duct system\u003c\/h2\u003e\n\u003cp\u003eA 4-ton size, or 48,000 BTU\/h: the YC348E2S11 belongs to the York YC3 (LX) series, between the 3.5-ton and 5-ton sizes of the same series. This R-454B condensing unit uses a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC3 is the basic model of York's R-454B LX range. Single-stage compressor, rotary at 1.5 and 2 tons and scroll in the other sizes, G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 (at least 500 h), up to 80 ft of piping: a simple, durable build. With the approved low-ambient kits it can cool down to 20°F (-7°C), useful when a room overheats in spring.\u003c\/p\u003e\n\u003ch3\u003eThe right size for your home\u003c\/h3\u003e\n\u003cp\u003eA large house with a single furnace and a single duct system often needs this size, especially when the bedrooms are upstairs and face south or west. We always check the furnace airflow and the size of the return ducts before recommending this size.\u003c\/p\u003e\n\u003ch3\u003eWhat the manufacturer's spec sheet says\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 13.4 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 76 dBA. It needs a 208\/230 V single-phase circuit with a 29.3 A minimum circuit ampacity and a 50 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 3.25 lb (1.47 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 35 1\/4 x 31 3\/4 in at the base and 33 1\/4 in high, with an operating weight of 210 lb, 15 lb more than the 3.5-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eRunning on R-454B, this condensing unit meets the Canadian rules now in force for new air conditioners. R-454B is mildly flammable (A2L class): the indoor section must be approved for it, and the installation follows the manufacturer's instructions.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eOther York series offered at 4 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc6-lx-4-tonnes-48000-btu-r454b\"\u003eYork YC6 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc4-lx-4-tonnes-48000-btu-r454b\"\u003eYork YC4 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-ycg-lx-4-tonnes-48000-btu-r410a\"\u003eYork YCG LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 7\/8 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eThe next step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YC348E2S11: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395110170916,"sku":"YC348E2S11","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC3_YC348E2S11_00_4_TONNES_48000_BTU_R454B_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692127"},{"product_id":"climatiseur-central-york-yc6-lx-5-tonnes-60000-btu-r454b","title":"YORK YC6 LX Central Air Conditioner | 5 Tons - 60000 BTU - R454B","description":"\u003ch2\u003eA 5-ton York, when the house truly calls for it\u003c\/h2\u003e\n\u003cp\u003eThe YC660E2S11 is the 5-ton (60,000 BTU\/h) condensing unit of the York YC6 (LX) series, the largest of the 5 sizes we offer in this series. It runs on R-454B, with a two-stage scroll compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC6 is the two-stage series of York's R-454B LX range, up to 18 SEER2 depending on size and match. From 2 to 5 tons, its two-stage scroll compressor spends most of its time at reduced capacity, for drier air and quieter operation, and only goes to full capacity when needed. The 1.5-ton size uses a single-stage rotary compressor instead.\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eIt is aimed at very large houses cooled through a single duct system: multi-storey properties and heavily glazed or extended homes. Before talking about 5 tons, we check that it is the right choice: in some very large homes, two smaller systems, one per floor, give better comfort.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 16 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 75 dBA. Electrical: 208\/230 V single-phase circuit, 31.6 A minimum ampacity, 50 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 5.5 lb (2.49 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 38 x 34 1\/4 in at the base and 42 3\/4 in high, with an operating weight of 255 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eR-454B replaces R-410A in new air conditioners sold in Canada. It is an A2L-class refrigerant: we install it with an indoor section approved for it, following the manufacturer's requirements.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eSame size, other series: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc4-lx-5-tonnes-60000-btu-r454b\"\u003eYork YC4 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc3-lx-5-tonnes-60000-btu-r454b\"\u003eYork YC3 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-5-tonnes-60000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eA Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 7\/8 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eWe work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eThe next step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YC660E2S11: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395111776548,"sku":"YC660E2S11","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC6_YC660E2S11_00_5_TONNES_60000_BTU_R454B_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yc2d-lx-3-5-tonnes-42000-btu-r410a","title":"YORK YC2D LX Central Air Conditioner | 3.5 Tons - 42000 BTU - R410A","description":"\u003ch2\u003eA 3.5-ton York for a large house on a single duct system\u003c\/h2\u003e\n\u003cp\u003eThe YC2D42SB21S is the 3.5-ton (42,000 BTU\/h) condensing unit of the York YC2D (LX) series, between the 3-ton and 4-ton sizes of the same series. It runs on R-410A, with a single-stage scroll compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC2D belongs to York's LX range, here in R-410A and on clearance. It is the range's basic model, rated 13.4 SEER2 by York, with a single-stage compressor (rotary at 1.5 and 2 tons, scroll in the other sizes), G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 (at least 500 h). The limited warranty is 10 years on the compressor, and the parts warranty goes from 5 to 10 years with registration.\u003c\/p\u003e\n\u003ch3\u003eThe right size for your home\u003c\/h3\u003e\n\u003cp\u003eA large house with a single furnace and a single duct system often needs this size, especially when the bedrooms are upstairs and face south or west. At this size, duct capacity matters as much as the unit's: undersized ducts make the air noisy at the grilles and reduce efficiency.\u003c\/p\u003e\n\u003ch3\u003eTechnical data worth knowing\u003c\/h3\u003e\n\u003cp\u003eYork publishes a range of 13.4 to 14.75 SEER2 for this size, depending on the matched indoor section; the condensing unit alone has no certified rating. The spec sheet lists a sound power of 76 dBA. Electrical: 208\/230 V single-phase circuit, 21.1 A minimum ampacity, 35 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 4.94 lb (2.24 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 29 1\/4 x 29 1\/4 in at the base and 36 1\/4 in high, with an operating weight of 195 lb, 45 lb more than the 3-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eManufacturers are gradually replacing R-410A with R-454B and R-32 in their new series, so this model is offered until stock runs out. It is most attractive if your current R-410A coil is recent and compatible.\u003c\/p\u003e\n\u003cp\u003eThis condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.\u003c\/p\u003e\n\u003cp\u003eOther York series offered at 3.5 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-ycg-lx-3-5-tonnes-42000-btu-r410a\"\u003eYork YCG LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-3-5-tonnes-42000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc3-lx-3-5-tonnes-42000-btu-r454b\"\u003eYork YC3 LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eA Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 7\/8 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm whether 3.5 tons is the right size, check the panel and the ducts, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395112235300,"sku":"YC2D42SB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC2D_YC2D42SB21S_00_3_5_TONNES_42000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692129"},{"product_id":"climatiseur-central-york-yc2e-lx-3-5-tonnes-42000-btu-r410a","title":"YORK YC2E LX Central Air Conditioner | 3.5 Tons - 42000 BTU - R410A","description":"\u003ch2\u003e3.5 tons for multi-storey houses and large open-plan spaces\u003c\/h2\u003e\n\u003cp\u003eAt 42,000 BTU\/h, the YC2E42SB21S is the 3.5-ton size of the York YC2E (LX) series, between the 3-ton and 4-ton sizes of the same series. It is the outdoor unit of an R-410A central air conditioner, fitted with a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC2E is the 14.3 SEER2 version of York's R-410A LX range, offered on clearance while stock lasts. Same single-stage scroll compressor and same cabinet of G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 as the YC2D, with better efficiency. With the approved low-ambient kits it can cool down to 20°F (-7°C).\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eIt is chosen for recent open-plan houses, extensions and homes whose windows get a lot of afternoon sun. At this size, duct capacity matters as much as the unit's: undersized ducts make the air noisy at the grilles and reduce efficiency.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eYork publishes a range of 14.3 to 15.75 SEER2 for this size, depending on the matched indoor section; the condensing unit alone has no certified rating. The spec sheet lists a sound power of 73 dBA. Electrical: 208\/230 V single-phase circuit, 23.4 A minimum ampacity, 40 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 5.06 lb (2.30 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 35 1\/4 x 31 3\/4 in at the base and 36 1\/4 in high, with an operating weight of 215 lb, 30 lb more than the 3-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eRunning on R-410A, this condensing unit is part of the stock still available: manufacturers are gradually moving to R-454B and R-32 in their new series. It is a good option to replace an R-410A unit while keeping a coil in good condition.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eSame size, other series: \u003ca href=\"\/en\/products\/climatiseur-central-york-ycg-lx-3-5-tonnes-42000-btu-r410a\"\u003eYork YCG LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-3-5-tonnes-42000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc3-lx-3-5-tonnes-42000-btu-r454b\"\u003eYork YC3 LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 7\/8 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm whether 3.5 tons is the right size, check the panel and the ducts, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395115282724,"sku":"YC2E42SB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC2E_YC2E42SB21S_00_3_5_TONNES_42000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692129"},{"product_id":"climatiseur-central-york-ycg-lx-5-tonnes-60000-btu-r410a","title":"YORK YCG LX Central Air Conditioner | 5 Tons - 60000 BTU - R410A","description":"\u003ch2\u003e5 tons of central air for very large houses\u003c\/h2\u003e\n\u003cp\u003eA 5-ton size, or 60,000 BTU\/h: the YCG60B21S belongs to the York YCG (LX) series, the largest of the 6 sizes we offer in this series. This R-410A condensing unit uses a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YCG is a York LX R-410A condensing unit, offered from 2 to 5 tons on clearance. Its paint is tested for at least 750 hours of salt spray, more than the other LX models. The limited warranty is 10 years on the compressor, with 10 years on parts if the unit is registered.\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eIt is aimed at very large houses cooled through a single duct system: multi-storey properties and heavily glazed or extended homes. At this size, the ducts, the furnace and the electrical panel all have to keep up; we check each of them during the estimate.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eThe spec sheet lists a sound power of 74 dBA. It needs a 208\/230 V single-phase circuit with a 32.4 A minimum circuit ampacity and a 50 A maximum time-delay fuse or breaker. The unit ships with a factory charge of 7.88 lb (3.57 kg) of R-410A, which our technicians adjust to the actual piping length.\u003c\/p\u003e\n\u003cp\u003eThe cabinet measures 38 x 34 1\/4 in at the base and 42 3\/4 in high, with an operating weight of 235 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eRunning on R-410A, this condensing unit is part of the stock still available: manufacturers are gradually moving to R-454B and R-32 in their new series. It is a good option to replace an R-410A unit while keeping a coil in good condition.\u003c\/p\u003e\n\u003cp\u003eNote: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.\u003c\/p\u003e\n\u003cp\u003eTo compare, still at 5 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-5-tonnes-60000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-5-tonnes-60000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yce-lx-5-tonnes-60000-btu-r410a\"\u003eYork YCE LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eA Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 7\/8 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTorn between two sizes or two series? Ask for a free estimate: we compare the options for your home and give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395116691748,"sku":"YCG60B21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YCG_YCG60B21S_00_5_TONNES_60000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yc4-lx-5-tonnes-60000-btu-r454b","title":"YORK YC4 LX Central Air Conditioner | 5 Tons - 60000 BTU - R454B","description":"\u003ch2\u003eA 5-ton York, when the house truly calls for it\u003c\/h2\u003e\n\u003cp\u003eA 5-ton size, or 60,000 BTU\/h: the YC460E2S11 belongs to the York YC4 (LX) series, the largest of the 6 sizes we offer in this series. This R-454B condensing unit uses a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC4 moves York's R-454B LX range one step up in efficiency, up to 16 SEER2 depending on size and match. It comes from 2 to 5 tons, with a single-stage scroll compressor and the range's G90-equivalent steel cabinet. The limited warranty is 10 years on the compressor.\u003c\/p\u003e\n\u003ch3\u003eThe right size for your home\u003c\/h3\u003e\n\u003cp\u003eIt is aimed at very large houses cooled through a single duct system: multi-storey properties and heavily glazed or extended homes. At this size, the ducts, the furnace and the electrical panel all have to keep up; we check each of them during the estimate.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 14.3 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 75 dBA. Electrical: 208\/230 V single-phase circuit, 30.7 A minimum ampacity, 50 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 5.19 lb (2.35 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 38 x 34 1\/4 in at the base and 42 3\/4 in high, with an operating weight of 235 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eRunning on R-454B, this condensing unit meets the Canadian rules now in force for new air conditioners. R-454B is mildly flammable (A2L class): the indoor section must be approved for it, and the installation follows the manufacturer's instructions.\u003c\/p\u003e\n\u003cp\u003eNote: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.\u003c\/p\u003e\n\u003cp\u003eTo compare, still at 5 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc6-lx-5-tonnes-60000-btu-r454b\"\u003eYork YC6 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc3-lx-5-tonnes-60000-btu-r454b\"\u003eYork YC3 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxv-affinity-5-tonnes-60000-btu-r410a\"\u003eYork YXV Affinity\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 7\/8 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YC460E2S11: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395117379876,"sku":"YC460E2S11","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC4_YC460E2S11_00_5_TONNES_60000_BTU_R454B_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692127"},{"product_id":"climatiseur-central-york-yc3-lx-5-tonnes-60000-btu-r454b","title":"YORK YC3 LX Central Air Conditioner | 5 Tons - 60000 BTU - R454B","description":"\u003ch2\u003eA 5-ton York, when the house truly calls for it\u003c\/h2\u003e\n\u003cp\u003eAt 60,000 BTU\/h, the YC360E2S11 is the 5-ton size of the York YC3 (LX) series, the largest of the 7 sizes we offer in this series. It is the outdoor unit of an R-454B central air conditioner, fitted with a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC3 is the basic model of York's R-454B LX range. Single-stage compressor, rotary at 1.5 and 2 tons and scroll in the other sizes, G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 (at least 500 h), up to 80 ft of piping: a simple, durable build. With the approved low-ambient kits it can cool down to 20°F (-7°C), useful when a room overheats in spring.\u003c\/p\u003e\n\u003ch3\u003eThe right size for your home\u003c\/h3\u003e\n\u003cp\u003eIt is kept for houses where 4 tons is no longer enough, for example a large multi-storey house with a lot of glazing or a major extension. At this size, the ducts, the furnace and the electrical panel all have to keep up; we check each of them during the estimate.\u003c\/p\u003e\n\u003ch3\u003eTechnical data worth knowing\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 13.4 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 77 dBA. Electrical: 208\/230 V single-phase circuit, 30.9 A minimum ampacity, 50 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 3.62 lb (1.64 kg) of R-454B, which our technicians adjust to the actual piping length. The cabinet measures 38 x 34 1\/4 in at the base and 36 1\/4 in high, with an operating weight of 230 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eR-454B has a much lower global warming potential than the R-410A it replaces. Like any A2L refrigerant, it requires a compatible indoor section and an installation that follows the manufacturer's instructions.\u003c\/p\u003e\n\u003cp\u003eNote: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.\u003c\/p\u003e\n\u003cp\u003eTo compare, still at 5 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc4-lx-5-tonnes-60000-btu-r454b\"\u003eYork YC4 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc6-lx-5-tonnes-60000-btu-r454b\"\u003eYork YC6 LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yce-lx-5-tonnes-60000-btu-r410a\"\u003eYork YCE LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 7\/8 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YC360E2S11: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395117543716,"sku":"YC360E2S11","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC3_YC360E2S11_00_5_TONNES_60000_BTU_R454B_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692128"},{"product_id":"climatiseur-central-york-yc2f-lx-2-tonnes-24000-btu-r410a","title":"YORK YC2F LX Central Air Conditioner | 2 Tons - 24000 BTU - R410A","description":"\u003ch2\u003eA small York size to add central air without overloading the panel\u003c\/h2\u003e\n\u003cp\u003eA 2-ton size, or 24,000 BTU\/h: the YC2F24SB21S belongs to the York YC2F (LX) series, the smallest of the 3 sizes we offer in this series. This R-410A condensing unit uses a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC2F is the most efficient single-stage R-410A York LX, rated 15.2 SEER2 by York. We have it in 2, 2.5 and 3 tons only, on clearance. It keeps the range's scroll compressor, G90-equivalent steel cabinet and 80 ft of allowable piping.\u003c\/p\u003e\n\u003ch3\u003eThe right size for your home\u003c\/h3\u003e\n\u003cp\u003eThis size is aimed at condos, townhouses and modest bungalows that already have ductwork. A bigger unit would short-cycle there. In a small home, cycle length is what matters: the longer the cycles, the drier the air and the more real the comfort. On the electrical side, a 25 A maximum breaker is enough, which often avoids major panel work.\u003c\/p\u003e\n\u003ch3\u003eWhat the manufacturer's spec sheet says\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 15.2 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 72 dBA. Electrical: 208\/230 V single-phase circuit, 16.5 A minimum ampacity, 25 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 3.31 lb (1.50 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 29 1\/4 x 29 1\/4 in at the base and 26 3\/4 in high, with an operating weight of 140 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eRunning on R-410A, this condensing unit is part of the stock still available: manufacturers are gradually moving to R-454B and R-32 in their new series. It is a good option to replace an R-410A unit while keeping a coil in good condition.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eSame size, other series: \u003ca href=\"\/en\/products\/climatiseur-central-york-yxv-affinity-2-tonnes-24000-btu-r410a\"\u003eYork YXV Affinity\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxt-affinity-2-tonnes-24000-btu-r410a\"\u003eYork YXT Affinity\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-2-tonnes-24000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eA Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 3\/4 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eThe next step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTorn between two sizes or two series? Ask for a free estimate: we compare the options for your home and give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395120820516,"sku":"YC2F24SB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC2F_YC2F24SB21S_00_2_TONNES_24000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692128"},{"product_id":"climatiseur-central-york-yc2d-lx-4-tonnes-48000-btu-r410a","title":"YORK YC2D LX Central Air Conditioner | 4 Tons - 48000 BTU - R410A","description":"\u003ch2\u003e4 tons for multi-storey houses and large open-plan spaces\u003c\/h2\u003e\n\u003cp\u003eA 4-ton size, or 48,000 BTU\/h: the YC2D48SB21S belongs to the York YC2D (LX) series, between the 3.5-ton and 5-ton sizes of the same series. This R-410A condensing unit uses a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC2D belongs to York's LX range, here in R-410A and on clearance. It is the range's basic model, rated 13.4 SEER2 by York, with a single-stage compressor (rotary at 1.5 and 2 tons, scroll in the other sizes), G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 (at least 500 h). The limited warranty is 10 years on the compressor, and the parts warranty goes from 5 to 10 years with registration.\u003c\/p\u003e\n\u003ch3\u003eThe right size for your home\u003c\/h3\u003e\n\u003cp\u003eThis size targets large multi-storey houses, open-plan layouts and heavily glazed homes, where a smaller unit struggles to keep the top floor comfortable. We always check the furnace airflow and the size of the return ducts before recommending this size.\u003c\/p\u003e\n\u003ch3\u003eWhat the manufacturer's spec sheet says\u003c\/h3\u003e\n\u003cp\u003eYork publishes a range of 13.4 to 14.5 SEER2 for this size, depending on the matched indoor section; the condensing unit alone has no certified rating. The spec sheet lists a sound power of 76 dBA. It needs a 208\/230 V single-phase circuit with a 25.7 A minimum circuit ampacity and a 45 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 4.69 lb (2.13 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 35 1\/4 x 31 3\/4 in at the base and 33 1\/4 in high, with an operating weight of 200 lb, 5 lb more than the 3.5-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eManufacturers are gradually replacing R-410A with R-454B and R-32 in their new series, so this model is offered until stock runs out. It is most attractive if your current R-410A coil is recent and compatible.\u003c\/p\u003e\n\u003cp\u003eNote: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.\u003c\/p\u003e\n\u003cp\u003eOther York series offered at 4 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yce-lx-4-tonnes-48000-btu-r410a\"\u003eYork YCE LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-ycg-lx-4-tonnes-48000-btu-r410a\"\u003eYork YCG LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-4-tonnes-48000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 7\/8 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YC2D48SB21S: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395124031780,"sku":"YC2D48SB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC2D_YC2D48SB21S_00_4_TONNES_48000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692129"},{"product_id":"climatiseur-central-york-yxv-affinity-2-tonnes-24000-btu-r410a","title":"YORK YXV Affinity Central Air Conditioner | 2 Tons - 24000 BTU - R410A","description":"\u003ch2\u003eA small York size to add central air without overloading the panel\u003c\/h2\u003e\n\u003cp\u003eA 2-ton size, or 24,000 BTU\/h: the YXV24B21S belongs to the York YXV (Affinity) series, the smallest of the 4 sizes we offer in this series. This R-410A condensing unit uses a variable-speed compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YXV is the variable-speed model of York's Affinity range, in R-410A and on clearance. Its scroll compressor modulates its output to keep a very steady temperature. The cabinet paint is tested for at least 1,000 hours of salt spray, and the coverage includes a limited lifetime compressor warranty if the unit is registered.\u003c\/p\u003e\n\u003ch3\u003eWhich homes does it suit?\u003c\/h3\u003e\n\u003cp\u003eIt is often chosen to add air conditioning to a small house heated by an electric furnace: a coil is added on the furnace, and the condensing unit does the rest outside. A well-chosen size dehumidifies better: an oversized unit cools quickly, shuts off right away and leaves the house cool but clammy. On the electrical side, a 30 A maximum breaker is enough, which often avoids major panel work.\u003c\/p\u003e\n\u003ch3\u003eTechnical data worth knowing\u003c\/h3\u003e\n\u003cp\u003eAt 69 dBA of sound power, it is the quietest size in the series. Electrical: 208\/230 V single-phase circuit, 17.4 A minimum ampacity, 30 A maximum time-delay fuse or breaker. The unit ships with a factory charge of 7.5 lb (3.40 kg) of R-410A, which our technicians adjust to the actual piping length.\u003c\/p\u003e\n\u003cp\u003eThe cabinet measures 35 1\/2 x 32 in at the base and 40 1\/4 in high, with an operating weight of 194 lb. The manufacturer approves cooling down to 35°F (2°C) outdoors, without modification.\u003c\/p\u003e\n\u003cp\u003eRunning on R-410A, this condensing unit is part of the stock still available: manufacturers are gradually moving to R-454B and R-32 in their new series. It is a good option to replace an R-410A unit while keeping a coil in good condition.\u003c\/p\u003e\n\u003cp\u003eThis condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.\u003c\/p\u003e\n\u003cp\u003eSame size, other series: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2f-lx-2-tonnes-24000-btu-r410a\"\u003eYork YC2F LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-ycg-lx-2-tonnes-24000-btu-r410a\"\u003eYork YCG LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxt-affinity-2-tonnes-24000-btu-r410a\"\u003eYork YXT Affinity\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 3\/4 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm whether 2 tons is the right size, check the panel and the ducts, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395125539108,"sku":"YXV24B21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YXV_YXV24B21S_00_2_TONNES_24000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yc2e-lx-4-tonnes-48000-btu-r410a","title":"YORK YC2E LX Central Air Conditioner | 4 Tons - 48000 BTU - R410A","description":"\u003ch2\u003eA 4-ton York for a large house on a single duct system\u003c\/h2\u003e\n\u003cp\u003eThe YC2E48SB21S is the 4-ton (48,000 BTU\/h) condensing unit of the York YC2E (LX) series, between the 3.5-ton and 5-ton sizes of the same series. It runs on R-410A, with a single-stage scroll compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC2E is the 14.3 SEER2 version of York's R-410A LX range, offered on clearance while stock lasts. Same single-stage scroll compressor and same cabinet of G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 as the YC2D, with better efficiency. With the approved low-ambient kits it can cool down to 20°F (-7°C).\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eA large house with a single furnace and a single duct system often needs this size, especially when the bedrooms are upstairs and face south or west. At this size, duct capacity matters as much as the unit's: undersized ducts make the air noisy at the grilles and reduce efficiency.\u003c\/p\u003e\n\u003ch3\u003eWhat the manufacturer's spec sheet says\u003c\/h3\u003e\n\u003cp\u003eYork publishes a range of 13.8 to 15.25 SEER2 for this size, depending on the matched indoor section; the condensing unit alone has no certified rating. The spec sheet lists a sound power of 76 dBA. It needs a 208\/230 V single-phase circuit with a 24.0 A minimum circuit ampacity and a 40 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 4.81 lb (2.18 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 35 1\/4 x 31 3\/4 in at the base and 33 1\/4 in high, with an operating weight of 210 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eThis model runs on R-410A, a refrigerant that manufacturers are gradually replacing with R-454B and R-32 in their new series. It is offered while our suppliers' stock lasts, and it suits replacing an R-410A condensing unit on a compatible coil.\u003c\/p\u003e\n\u003cp\u003eThis condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.\u003c\/p\u003e\n\u003cp\u003eOther York series offered at 4 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-4-tonnes-48000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxv-affinity-4-tonnes-48000-btu-r410a\"\u003eYork YXV Affinity\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yce-lx-4-tonnes-48000-btu-r410a\"\u003eYork YCE LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 7\/8 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eThe next step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YC2E48SB21S: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395127144740,"sku":"YC2E48SB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC2E_YC2E48SB21S_00_4_TONNES_48000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692128"},{"product_id":"climatiseur-central-york-yxt-affinity-2-tonnes-24000-btu-r410a","title":"YORK YXT Affinity Central Air Conditioner | 2 Tons - 24000 BTU - R410A","description":"\u003ch2\u003eThe 2-ton YXT: cooling a small home that already has ductwork\u003c\/h2\u003e\n\u003cp\u003eAt 24,000 BTU\/h, the YXT24B21S is the 2-ton size of the York YXT (Affinity) series, the smallest of the 4 sizes we offer in this series. It is the outdoor unit of an R-410A central air conditioner, fitted with a two-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YXT belongs to the Affinity range, York's premium line, here in R-410A and on clearance. Its two-stage scroll compressor and a cabinet whose paint is tested for at least 1,000 hours of salt spray make it a durable, quiet unit. It is rated 18 SEER2 by York.\u003c\/p\u003e\n\u003ch3\u003eWhich homes does it suit?\u003c\/h3\u003e\n\u003cp\u003eThis size is aimed at condos, townhouses and modest bungalows that already have ductwork. A bigger unit would short-cycle there. A well-chosen size dehumidifies better: an oversized unit cools quickly, shuts off right away and leaves the house cool but clammy. On the electrical side, a 25 A maximum breaker is enough, which often avoids major panel work.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 18 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. At 68 dBA of sound power, it is the quietest size in the series. It needs a 208\/230 V single-phase circuit with a 15.3 A minimum circuit ampacity and a 25 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 9.44 lb (4.28 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 38 1\/4 x 34 1\/2 in at the base and 40 1\/4 in high, with an operating weight of 195 lb. The manufacturer approves cooling down to 35°F (1.7°C) outdoors, without modification.\u003c\/p\u003e\n\u003cp\u003eManufacturers are gradually replacing R-410A with R-454B and R-32 in their new series, so this model is offered until stock runs out. It is most attractive if your current R-410A coil is recent and compatible.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eSame size, other series: \u003ca href=\"\/en\/products\/climatiseur-central-york-yxv-affinity-2-tonnes-24000-btu-r410a\"\u003eYork YXV Affinity\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-2-tonnes-24000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-2-tonnes-24000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eA Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 3\/4 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YXT24B21S: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395127701796,"sku":"YXT24B21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YXT_YXT24B21S_00_2_TONNES_24000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yce-lx-4-tonnes-48000-btu-r410a","title":"YORK YCE LX Central Air Conditioner | 4 Tons - 48000 BTU - R410A","description":"\u003ch2\u003eA 4-ton York for a large house on a single duct system\u003c\/h2\u003e\n\u003cp\u003eA 4-ton size, or 48,000 BTU\/h: the YCE48B21S belongs to the York YCE (LX) series, the smallest of the 2 sizes we offer in this series. This R-410A condensing unit uses a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YCE is a York LX R-410A condensing unit with a single-stage scroll compressor, which we offer in 4 and 5 tons only, on clearance. It suits replacing a large R-410A condensing unit on a compatible coil, with a G90-equivalent steel cabinet tested in salt spray.\u003c\/p\u003e\n\u003ch3\u003eThe right size for your home\u003c\/h3\u003e\n\u003cp\u003eThis size targets large multi-storey houses, open-plan layouts and heavily glazed homes, where a smaller unit struggles to keep the top floor comfortable. We always check the furnace airflow and the size of the return ducts before recommending this size.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eThe spec sheet lists a sound power of 75 dBA. Electrical: 208\/230 V single-phase circuit, 25.7 A minimum ampacity, 45 A maximum time-delay fuse or breaker. The unit ships with a factory charge of 4.94 lb (2.24 kg) of R-410A, which our technicians adjust to the actual piping length.\u003c\/p\u003e\n\u003cp\u003eThe cabinet measures 35 1\/4 x 31 3\/4 in at the base and 33 1\/4 in high, with an operating weight of 200 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eRunning on R-410A, this condensing unit is part of the stock still available: manufacturers are gradually moving to R-454B and R-32 in their new series. It is a good option to replace an R-410A unit while keeping a coil in good condition.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eSame size, other series: \u003ca href=\"\/en\/products\/climatiseur-central-york-yxv-affinity-4-tonnes-48000-btu-r410a\"\u003eYork YXV Affinity\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-4-tonnes-48000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-ycg-lx-4-tonnes-48000-btu-r410a\"\u003eYork YCG LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eA Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 7\/8 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm whether 4 tons is the right size, check the panel and the ducts, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395127800100,"sku":"YCE48B21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YCE_YCE48B21S_00_4_TONNES_48000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692129"},{"product_id":"climatiseur-central-york-yc2f-lx-2-5-tonnes-30000-btu-r410a","title":"YORK YC2F LX Central Air Conditioner | 2.5 Tons - 30000 BTU - R410A","description":"\u003ch2\u003eCooling a whole mid-size house with a 2.5-ton York\u003c\/h2\u003e\n\u003cp\u003eThe YC2F30SB21S is the 2.5-ton (30,000 BTU\/h) condensing unit of the York YC2F (LX) series, between the 2-ton and 3-ton sizes of the same series. It runs on R-410A, with a single-stage scroll compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC2F is the most efficient single-stage R-410A York LX, rated 15.2 SEER2 by York. We have it in 2, 2.5 and 3 tons only, on clearance. It keeps the range's scroll compressor, G90-equivalent steel cabinet and 80 ft of allowable piping.\u003c\/p\u003e\n\u003ch3\u003eWhich homes does it suit?\u003c\/h3\u003e\n\u003cp\u003eYou find it in many cottages built from the 1980s to the 2000s, where an old condensing unit of the same size is reaching the end of its life. Before confirming the size, we look at the insulation, the orientation of the windows and the capacity of the ducts.\u003c\/p\u003e\n\u003ch3\u003eWhat the manufacturer's spec sheet says\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 15.2 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 72 dBA. Electrical: 208\/230 V single-phase circuit, 16.0 A minimum ampacity, 25 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 3.56 lb (1.62 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 29 1\/4 x 29 1\/4 in at the base and 30 in high, with an operating weight of 160 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eThis model runs on R-410A, a refrigerant that manufacturers are gradually replacing with R-454B and R-32 in their new series. It is offered while our suppliers' stock lasts, and it suits replacing an R-410A condensing unit on a compatible coil.\u003c\/p\u003e\n\u003cp\u003eNote: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.\u003c\/p\u003e\n\u003cp\u003eOther York series offered at 2.5 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-2-5-tonnes-30000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-2-5-tonnes-30000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-ycg-lx-2-5-tonnes-30000-btu-r410a\"\u003eYork YCG LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 3\/4 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTorn between two sizes or two series? Ask for a free estimate: we compare the options for your home and give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395128258852,"sku":"YC2F30SB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC2F_YC2F30SB21S_00_2_5_TONNES_30000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692129"},{"product_id":"climatiseur-central-york-yc2d-lx-5-tonnes-60000-btu-r410a","title":"YORK YC2D LX Central Air Conditioner | 5 Tons - 60000 BTU - R410A","description":"\u003ch2\u003eThe 5-ton YC2D, the largest residential size\u003c\/h2\u003e\n\u003cp\u003eThe YC2D60SB21S is the 5-ton (60,000 BTU\/h) condensing unit of the York YC2D (LX) series, the largest of the 7 sizes we offer in this series. It runs on R-410A, with a single-stage scroll compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC2D belongs to York's LX range, here in R-410A and on clearance. It is the range's basic model, rated 13.4 SEER2 by York, with a single-stage compressor (rotary at 1.5 and 2 tons, scroll in the other sizes), G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 (at least 500 h). The limited warranty is 10 years on the compressor, and the parts warranty goes from 5 to 10 years with registration.\u003c\/p\u003e\n\u003ch3\u003eThe right size for your home\u003c\/h3\u003e\n\u003cp\u003eIt is aimed at very large houses cooled through a single duct system: multi-storey properties and heavily glazed or extended homes. Before talking about 5 tons, we check that it is the right choice: in some very large homes, two smaller systems, one per floor, give better comfort.\u003c\/p\u003e\n\u003ch3\u003eTechnical data worth knowing\u003c\/h3\u003e\n\u003cp\u003eYork publishes a range of 13.4 to 14 SEER2 for this size, depending on the matched indoor section; the condensing unit alone has no certified rating. The spec sheet lists a sound power of 77 dBA. Electrical: 208\/230 V single-phase circuit, 29.1 A minimum ampacity, 50 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 5.56 lb (2.52 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 38 x 34 1\/4 in at the base and 36 1\/4 in high, with an operating weight of 230 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eThis model runs on R-410A, a refrigerant that manufacturers are gradually replacing with R-454B and R-32 in their new series. It is offered while our suppliers' stock lasts, and it suits replacing an R-410A condensing unit on a compatible coil.\u003c\/p\u003e\n\u003cp\u003eNote: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.\u003c\/p\u003e\n\u003cp\u003eSame size, other series: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-5-tonnes-60000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yce-lx-5-tonnes-60000-btu-r410a\"\u003eYork YCE LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxv-affinity-5-tonnes-60000-btu-r410a\"\u003eYork YXV Affinity\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eA Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 7\/8 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eThe next step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YC2D60SB21S: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395130552612,"sku":"YC2D60SB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC2D_YC2D60SB21S_00_5_TONNES_60000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yxv-affinity-3-tonnes-36000-btu-r410a","title":"YORK YXV Affinity Central Air Conditioner | 3 Tons - 36000 BTU - R410A","description":"\u003ch2\u003e3 tons, the size that suits many Greater Montreal homes\u003c\/h2\u003e\n\u003cp\u003eThe YXV36B21S is the 3-ton (36,000 BTU\/h) condensing unit of the York YXV (Affinity) series, between the 2-ton and 4-ton sizes of the same series. It runs on R-410A, with a variable-speed compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YXV is the variable-speed model of York's Affinity range, in R-410A and on clearance. Its scroll compressor modulates its output to keep a very steady temperature. The cabinet paint is tested for at least 1,000 hours of salt spray, and the coverage includes a limited lifetime compressor warranty if the unit is registered.\u003c\/p\u003e\n\u003ch3\u003eThe right size for your home\u003c\/h3\u003e\n\u003cp\u003eYou find it in many cottages built from the 1980s to the 2000s, where an old condensing unit of the same size is reaching the end of its life. An undersized unit runs non-stop during heat waves; an oversized one cools fast but dehumidifies poorly. We run the numbers before proposing anything.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eThe spec sheet lists a sound power of 73 dBA. It needs a 208\/230 V single-phase circuit with a 25.7 A minimum circuit ampacity and a 40 A maximum time-delay fuse or breaker. The unit ships with a factory charge of 7.38 lb (3.35 kg) of R-410A, which our technicians adjust to the actual piping length.\u003c\/p\u003e\n\u003cp\u003eThe cabinet measures 35 1\/2 x 32 in at the base and 40 1\/4 in high, with an operating weight of 205 lb, 11 lb more than the 2-ton size. The manufacturer approves cooling down to 35°F (2°C) outdoors, without modification.\u003c\/p\u003e\n\u003cp\u003eThis model runs on R-410A, a refrigerant that manufacturers are gradually replacing with R-454B and R-32 in their new series. It is offered while our suppliers' stock lasts, and it suits replacing an R-410A condensing unit on a compatible coil.\u003c\/p\u003e\n\u003cp\u003eNote: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.\u003c\/p\u003e\n\u003cp\u003eSame size, other series: \u003ca href=\"\/en\/products\/climatiseur-central-york-yxt-affinity-3-tonnes-36000-btu-r410a\"\u003eYork YXT Affinity\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-3-tonnes-36000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-3-tonnes-36000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eA Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 3\/4 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm whether 3 tons is the right size, check the panel and the ducts, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395131109668,"sku":"YXV36B21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YXV_YXV36B21S_00_3_TONNES_36000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yxt-affinity-3-tonnes-36000-btu-r410a","title":"YORK YXT Affinity Central Air Conditioner | 3 Tons - 36000 BTU - R410A","description":"\u003ch2\u003e3 tons, the size that suits many Greater Montreal homes\u003c\/h2\u003e\n\u003cp\u003eA 3-ton size, or 36,000 BTU\/h: the YXT36B21S belongs to the York YXT (Affinity) series, between the 2-ton and 4-ton sizes of the same series. This R-410A condensing unit uses a two-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YXT belongs to the Affinity range, York's premium line, here in R-410A and on clearance. Its two-stage scroll compressor and a cabinet whose paint is tested for at least 1,000 hours of salt spray make it a durable, quiet unit. It is rated 18 SEER2 by York.\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eThis size matches most Greater Montreal bungalows and cottages that already have ductwork, and it is also the one replaced most often. An undersized unit runs non-stop during heat waves; an oversized one cools fast but dehumidifies poorly. We run the numbers before proposing anything.\u003c\/p\u003e\n\u003ch3\u003eWhat the manufacturer's spec sheet says\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 18 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 69 dBA. Electrical: 208\/230 V single-phase circuit, 21.4 A minimum ampacity, 35 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 14.12 lb (6.41 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 38 1\/4 x 34 1\/2 in at the base and 46 1\/2 in high, with an operating weight of 265 lb, 70 lb more than the 2-ton size. The manufacturer approves cooling down to 35°F (1.7°C) outdoors, without modification.\u003c\/p\u003e\n\u003cp\u003eRunning on R-410A, this condensing unit is part of the stock still available: manufacturers are gradually moving to R-454B and R-32 in their new series. It is a good option to replace an R-410A unit while keeping a coil in good condition.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eOther York series offered at 3 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-3-tonnes-36000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-3-tonnes-36000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-ycg-lx-3-tonnes-36000-btu-r410a\"\u003eYork YCG LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 3\/4 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm whether 3 tons is the right size, check the panel and the ducts, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395132191012,"sku":"YXT36B21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YXT_YXT36B21S_00_3_TONNES_36000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yc2e-lx-5-tonnes-60000-btu-r410a","title":"YORK YC2E LX Central Air Conditioner | 5 Tons - 60000 BTU - R410A","description":"\u003ch2\u003eA 5-ton York, when the house truly calls for it\u003c\/h2\u003e\n\u003cp\u003eThe YC2E60SB21S is the 5-ton (60,000 BTU\/h) condensing unit of the York YC2E (LX) series, the largest of the 7 sizes we offer in this series. It runs on R-410A, with a single-stage scroll compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC2E is the 14.3 SEER2 version of York's R-410A LX range, offered on clearance while stock lasts. Same single-stage scroll compressor and same cabinet of G90-equivalent steel and a powder coat tested in salt spray to ASTM B117 as the YC2D, with better efficiency. With the approved low-ambient kits it can cool down to 20°F (-7°C).\u003c\/p\u003e\n\u003ch3\u003eWhich homes does it suit?\u003c\/h3\u003e\n\u003cp\u003eIt is aimed at very large houses cooled through a single duct system: multi-storey properties and heavily glazed or extended homes. At this size, the ducts, the furnace and the electrical panel all have to keep up; we check each of them during the estimate.\u003c\/p\u003e\n\u003ch3\u003eWhat the manufacturer's spec sheet says\u003c\/h3\u003e\n\u003cp\u003eYork publishes a range of 13.8 to 14.5 SEER2 for this size, depending on the matched indoor section; the condensing unit alone has no certified rating. The spec sheet lists a sound power of 76 dBA. It needs a 208\/230 V single-phase circuit with a 30.9 A minimum circuit ampacity and a 50 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 5.69 lb (2.58 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 38 x 34 1\/4 in at the base and 36 1\/4 in high, with an operating weight of 230 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eThis model runs on R-410A, a refrigerant that manufacturers are gradually replacing with R-454B and R-32 in their new series. It is offered while our suppliers' stock lasts, and it suits replacing an R-410A condensing unit on a compatible coil.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eSame size, other series: \u003ca href=\"\/en\/products\/climatiseur-central-york-yxt-affinity-5-tonnes-60000-btu-r410a\"\u003eYork YXT Affinity\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-ycg-lx-5-tonnes-60000-btu-r410a\"\u003eYork YCG LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxv-affinity-5-tonnes-60000-btu-r410a\"\u003eYork YXV Affinity\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eA Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 7\/8 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm whether 5 tons is the right size, check the panel and the ducts, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395132256548,"sku":"YC2E60SB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC2E_YC2E60SB21S_00_5_TONNES_60000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yce-lx-5-tonnes-60000-btu-r410a","title":"YORK YCE LX Central Air Conditioner | 5 Tons - 60000 BTU - R410A","description":"\u003ch2\u003eThe 5-ton YCE, the largest residential size\u003c\/h2\u003e\n\u003cp\u003eAt 60,000 BTU\/h, the YCE60B21S is the 5-ton size of the York YCE (LX) series, the largest of the 2 sizes we offer in this series. It is the outdoor unit of an R-410A central air conditioner, fitted with a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YCE is a York LX R-410A condensing unit with a single-stage scroll compressor, which we offer in 4 and 5 tons only, on clearance. It suits replacing a large R-410A condensing unit on a compatible coil, with a G90-equivalent steel cabinet tested in salt spray.\u003c\/p\u003e\n\u003ch3\u003eWhich homes does it suit?\u003c\/h3\u003e\n\u003cp\u003eIt is the largest residential size: it suits large properties whose furnace and ductwork were designed for that much airflow. At this size, the ducts, the furnace and the electrical panel all have to keep up; we check each of them during the estimate.\u003c\/p\u003e\n\u003ch3\u003eWhat the manufacturer's spec sheet says\u003c\/h3\u003e\n\u003cp\u003eThe spec sheet lists a sound power of 76 dBA. It needs a 208\/230 V single-phase circuit with a 31.7 A minimum circuit ampacity and a 50 A maximum time-delay fuse or breaker. The unit ships with a factory charge of 5.75 lb (2.61 kg) of R-410A, which our technicians adjust to the actual piping length.\u003c\/p\u003e\n\u003cp\u003eThe cabinet measures 38 x 34 1\/4 in at the base and 36 1\/4 in high, with an operating weight of 205 lb, 5 lb more than the 4-ton size. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eRunning on R-410A, this condensing unit is part of the stock still available: manufacturers are gradually moving to R-454B and R-32 in their new series. It is a good option to replace an R-410A unit while keeping a coil in good condition.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eSame size, other series: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-5-tonnes-60000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxt-affinity-5-tonnes-60000-btu-r410a\"\u003eYork YXT Affinity\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-5-tonnes-60000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 7\/8 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTorn between two sizes or two series? Ask for a free estimate: we compare the options for your home and give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395133141284,"sku":"YCE60B21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YCE_YCE60B21S_00_5_TONNES_60000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692129"},{"product_id":"climatiseur-central-york-yc2f-lx-3-tonnes-36000-btu-r410a","title":"YORK YC2F LX Central Air Conditioner | 3 Tons - 36000 BTU - R410A","description":"\u003ch2\u003eCooling a whole mid-size house with a 3-ton York\u003c\/h2\u003e\n\u003cp\u003eAt 36,000 BTU\/h, the YC2F36SB21S is the 3-ton size of the York YC2F (LX) series, the largest of the 3 sizes we offer in this series. It is the outdoor unit of an R-410A central air conditioner, fitted with a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YC2F is the most efficient single-stage R-410A York LX, rated 15.2 SEER2 by York. We have it in 2, 2.5 and 3 tons only, on clearance. It keeps the range's scroll compressor, G90-equivalent steel cabinet and 80 ft of allowable piping.\u003c\/p\u003e\n\u003ch3\u003eThe right size for your home\u003c\/h3\u003e\n\u003cp\u003eThis size matches most Greater Montreal bungalows and cottages that already have ductwork, and it is also the one replaced most often. Before confirming the size, we look at the insulation, the orientation of the windows and the capacity of the ducts.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 15.2 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 72 dBA. It needs a 208\/230 V single-phase circuit with a 17.7 A minimum circuit ampacity and a 30 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 4.81 lb (2.18 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 29 1\/4 x 31 3\/4 in at the base and 33 1\/4 in high, with an operating weight of 175 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eManufacturers are gradually replacing R-410A with R-454B and R-32 in their new series, so this model is offered until stock runs out. It is most attractive if your current R-410A coil is recent and compatible.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eOther York series offered at 3 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-3-tonnes-36000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxt-affinity-3-tonnes-36000-btu-r410a\"\u003eYork YXT Affinity\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-3-tonnes-36000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 3\/4 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We install throughout Greater Montreal: \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm whether 3 tons is the right size, check the panel and the ducts, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395136647460,"sku":"YC2F36SB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YC2F_YC2F36SB21S_00_3_TONNES_36000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692129"},{"product_id":"climatiseur-central-york-yxv-affinity-4-tonnes-48000-btu-r410a","title":"YORK YXV Affinity Central Air Conditioner | 4 Tons - 48000 BTU - R410A","description":"\u003ch2\u003e4 tons for multi-storey houses and large open-plan spaces\u003c\/h2\u003e\n\u003cp\u003eAt 48,000 BTU\/h, the YXV48B21S is the 4-ton size of the York YXV (Affinity) series, between the 3-ton and 5-ton sizes of the same series. It is the outdoor unit of an R-410A central air conditioner, fitted with a variable-speed compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YXV is the variable-speed model of York's Affinity range, in R-410A and on clearance. Its scroll compressor modulates its output to keep a very steady temperature. The cabinet paint is tested for at least 1,000 hours of salt spray, and the coverage includes a limited lifetime compressor warranty if the unit is registered.\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eA large house with a single furnace and a single duct system often needs this size, especially when the bedrooms are upstairs and face south or west. We always check the furnace airflow and the size of the return ducts before recommending this size.\u003c\/p\u003e\n\u003ch3\u003eTechnical data worth knowing\u003c\/h3\u003e\n\u003cp\u003eThe spec sheet lists a sound power of 73 dBA. Electrical: 208\/230 V single-phase circuit, 28.6 A minimum ampacity, 45 A maximum time-delay fuse or breaker. The unit ships with a factory charge of 14.56 lb (6.61 kg) of R-410A, which our technicians adjust to the actual piping length.\u003c\/p\u003e\n\u003cp\u003eThe cabinet measures 38 1\/4 x 34 1\/2 in at the base and 43 1\/4 in high, with an operating weight of 264 lb, 59 lb more than the 3-ton size. The manufacturer approves cooling down to 35°F (2°C) outdoors, without modification.\u003c\/p\u003e\n\u003cp\u003eRunning on R-410A, this condensing unit is part of the stock still available: manufacturers are gradually moving to R-454B and R-32 in their new series. It is a good option to replace an R-410A unit while keeping a coil in good condition.\u003c\/p\u003e\n\u003cp\u003eIt cools only: it does not heat and, sold alone, it is not eligible for the LogisVert grant. A central heat pump of the same size, which also heats, can be an option to compare.\u003c\/p\u003e\n\u003cp\u003eOther York series offered at 4 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yxt-affinity-4-tonnes-48000-btu-r410a\"\u003eYork YXT Affinity\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yce-lx-4-tonnes-48000-btu-r410a\"\u003eYork YCE LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-ycg-lx-4-tonnes-48000-btu-r410a\"\u003eYork YCG LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 7\/8 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm whether 4 tons is the right size, check the panel and the ducts, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395148247332,"sku":"YXV48B21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YXV_YXV48B21S_00_4_TONNES_48000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yxt-affinity-4-tonnes-48000-btu-r410a","title":"YORK YXT Affinity Central Air Conditioner | 4 Tons - 48000 BTU - R410A","description":"\u003ch2\u003eA 4-ton York for a large house on a single duct system\u003c\/h2\u003e\n\u003cp\u003eAt 48,000 BTU\/h, the YXT48B21S is the 4-ton size of the York YXT (Affinity) series, between the 3-ton and 5-ton sizes of the same series. It is the outdoor unit of an R-410A central air conditioner, fitted with a two-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YXT belongs to the Affinity range, York's premium line, here in R-410A and on clearance. Its two-stage scroll compressor and a cabinet whose paint is tested for at least 1,000 hours of salt spray make it a durable, quiet unit. It is rated 18 SEER2 by York.\u003c\/p\u003e\n\u003ch3\u003eWhich homes does it suit?\u003c\/h3\u003e\n\u003cp\u003eThis size targets large multi-storey houses, open-plan layouts and heavily glazed homes, where a smaller unit struggles to keep the top floor comfortable. At this size, duct capacity matters as much as the unit's: undersized ducts make the air noisy at the grilles and reduce efficiency.\u003c\/p\u003e\n\u003ch3\u003eTechnical data worth knowing\u003c\/h3\u003e\n\u003cp\u003eFor efficiency, the spec sheet gives 18 SEER2 (series rating per the manufacturer); the actual value depends on the matched indoor section. The spec sheet lists a sound power of 72 dBA. It needs a 208\/230 V single-phase circuit with a 28.2 A minimum circuit ampacity and a 45 A maximum time-delay fuse or breaker.\u003c\/p\u003e\n\u003cp\u003eThe unit ships with a factory charge of 13.94 lb (6.32 kg) of R-410A, which our technicians adjust to the actual piping length. The cabinet measures 38 1\/4 x 34 1\/2 in at the base and 46 1\/2 in high, with an operating weight of 295 lb. The manufacturer approves cooling down to 35°F (1.7°C) outdoors, without modification.\u003c\/p\u003e\n\u003cp\u003eThis model runs on R-410A, a refrigerant that manufacturers are gradually replacing with R-454B and R-32 in their new series. It is offered while our suppliers' stock lasts, and it suits replacing an R-410A condensing unit on a compatible coil.\u003c\/p\u003e\n\u003cp\u003eNote: this is a cooling-only unit, not eligible for LogisVert when sold alone. If heating interests you too, ask us for the price of an equivalent central heat pump.\u003c\/p\u003e\n\u003cp\u003eTo compare, still at 4 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-4-tonnes-48000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-4-tonnes-48000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-ycg-lx-4-tonnes-48000-btu-r410a\"\u003eYork YCG LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 7\/8 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eThe next step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eTorn between two sizes or two series? Ask for a free estimate: we compare the options for your home and give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395151294756,"sku":"YXT48B21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YXT_YXT48B21S_00_4_TONNES_48000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"},{"product_id":"climatiseur-central-york-yxv-affinity-5-tonnes-60000-btu-r410a","title":"YORK YXV Affinity Central Air Conditioner | 5 Tons - 60000 BTU - R410A","description":"\u003ch2\u003eA 5-ton York, when the house truly calls for it\u003c\/h2\u003e\n\u003cp\u003eThe YXV60B21S is the 5-ton (60,000 BTU\/h) condensing unit of the York YXV (Affinity) series, the largest of the 4 sizes we offer in this series. It runs on R-410A, with a variable-speed compressor, and it cools only. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YXV is the variable-speed model of York's Affinity range, in R-410A and on clearance. Its scroll compressor modulates its output to keep a very steady temperature. The cabinet paint is tested for at least 1,000 hours of salt spray, and the coverage includes a limited lifetime compressor warranty if the unit is registered.\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eIt is aimed at very large houses cooled through a single duct system: multi-storey properties and heavily glazed or extended homes. Before talking about 5 tons, we check that it is the right choice: in some very large homes, two smaller systems, one per floor, give better comfort.\u003c\/p\u003e\n\u003ch3\u003eTechnical data worth knowing\u003c\/h3\u003e\n\u003cp\u003eThe spec sheet lists a sound power of 74 dBA. Electrical: 208\/230 V single-phase circuit, 33.9 A minimum ampacity, 50 A maximum time-delay fuse or breaker. The unit ships with a factory charge of 15.06 lb (6.83 kg) of R-410A, which our technicians adjust to the actual piping length.\u003c\/p\u003e\n\u003cp\u003eThe cabinet measures 38 1\/4 x 34 1\/2 in at the base and 46 1\/2 in high, with an operating weight of 270 lb. The manufacturer approves cooling down to 35°F (2°C) outdoors, without modification.\u003c\/p\u003e\n\u003cp\u003eManufacturers are gradually replacing R-410A with R-454B and R-32 in their new series, so this model is offered until stock runs out. It is most attractive if your current R-410A coil is recent and compatible.\u003c\/p\u003e\n\u003cp\u003eThis condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.\u003c\/p\u003e\n\u003cp\u003eTo compare, still at 5 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yce-lx-5-tonnes-60000-btu-r410a\"\u003eYork YCE LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2d-lx-5-tonnes-60000-btu-r410a\"\u003eYork YC2D LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-5-tonnes-60000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eA Montreal family business for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work, so one contractor handles everything.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree visit: we measure and check the panel and the ducts;\u003c\/li\u003e\n\u003cli\u003eWritten quote, with the planned indoor section and electrical circuit;\u003c\/li\u003e\n\u003cli\u003eInstalling the condensing unit on a level base, and the indoor section;\u003c\/li\u003e\n\u003cli\u003eConnecting the piping with a 7\/8 in vapor valve, evacuation and charge adjusted to the actual length;\u003c\/li\u003e\n\u003cli\u003eElectrical hookup, full test run and a walk-through of how it works.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet a quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a free estimate request for the YXV60B21S: we validate the size on site and give you a written price, installation included. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395156701476,"sku":"YXV60B21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YXV_YXV60B21S_00_5_TONNES_60000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692130"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/collections\/CLIMATISEUR_CENTRAL_YORK_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.jpg?v=1795705800","url":"https:\/\/airgreen.ca\/en\/collections\/climatiseur-central-york-installation-a-montreal-laval-longueuil-rive-sud-et-rive-nord.oembed?page=2","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}