{"title":"Heat Pump Electrical Supplies","description":"\u003cp\u003eA heat pump runs well when its circuit is built for it. This collection gathers the electrical material our technicians install between the panel and the unit.\u003c\/p\u003e\u003ch2\u003eFrom the panel to the outdoor unit\u003c\/h2\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eOutdoor disconnect\u003c\/strong\u003e: cuts power on site during maintenance; sold individually or in a pack of 10.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003e14\/4 communication cable\u003c\/strong\u003e: 4 conductors of 14 gauge linking the outdoor unit to the indoor unit of a wall-mounted heat pump or a multi-zone head.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eCopper electrical wire\u003c\/strong\u003e: 8, 10, 12 and 14 gauge for the supply circuits of heating and cooling equipment.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eSiemens breakers\u003c\/strong\u003e: single-pole 15 A, single-pole 20 A and twin, for residential panels.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eSurge protection\u003c\/strong\u003e: a 20 kA surge protector and the RectorSeal RSH-50, alone or with a disconnect, for single-phase 120\/240 V AC equipment.\u003c\/li\u003e\u003c\/ul\u003e\u003ch2\u003eStart with the nameplate\u003c\/h2\u003e\u003cp\u003eThe size of the disconnect, the breaker and the wire is set from the ratings on the unit’s nameplate, under the Quebec Construction Code, Chapter V – Electricity. Most heat pumps run on 240 V and need a double-pole breaker; the single-pole models in this collection serve 120 V loads such as a condensate pump or an air exchanger. The breaker must also be a type your panel accepts: a photo of its label is enough for us to confirm it.\u003c\/p\u003e\u003ch2\u003eWired by AirGreen\u003c\/h2\u003e\u003cp\u003eElectrical connections are reserved for a licensed electrical contractor. AirGreen holds RBQ licence 5645-9605-01, subclass 16 (electricity), and is a member of the CMEQ. We make them in Montréal, Laval, Longueuil, on the South Shore and on the North Shore. To check availability or get a quote, call us at \u003ca href=\"tel:+15143162973\"\u003e514 316-2973\u003c\/a\u003e or email \u003ca href=\"mailto:sales@airgreen.ca\"\u003esales@airgreen.ca\u003c\/a\u003e with the item, the gauge or model, and the quantity.\u003c\/p\u003e","products":[{"product_id":"sectionneur-exterieur-pour-thermopompe-disconnect","title":"Outdoor Disconnect Switch for Heat Pump","description":"\u003cp\u003eThe \u003cstrong\u003eoutdoor disconnect switch\u003c\/strong\u003e, often just called a \u003cem\u003edisconnect\u003c\/em\u003e, is the switch installed near the \u003cstrong\u003eoutdoor unit\u003c\/strong\u003e of a heat pump or air conditioner. It lets you cut power to the unit on the spot, during maintenance or a repair, without going to the electrical panel. It is offered individually or in a pack of 10.\u003c\/p\u003e\n\u003ch2\u003eWhy a disconnect near the outdoor unit\u003c\/h2\u003e\n\u003cp\u003eWhen a technician opens the outdoor unit, they have to be certain nobody will turn the power back on while they work. The electrical panel is often in the basement, far from the unit. The disconnect, installed within sight of the unit, settles the matter: you shut it off, you check, you work. A means of disconnection near the unit is part of a compliant electrical installation; your electrician checks its location according to the \u003cstrong\u003eQuébec Construction Code, Chapter V – Electricity\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eChoosing and placing the disconnect\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe rating is determined from the outdoor unit’s \u003cstrong\u003enameplate\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eInstall it near the unit, in a spot that is accessible at all times, out of the way of snow sliding off the roof.\u003c\/li\u003e\n\u003cli\u003eThe pack of 10 is for installers who put in several units.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eA job for an electrician\u003c\/h3\u003e\n\u003cp\u003eElectrical connection is reserved for an electrical contractor. AirGreen holds RBQ licence 5645-9605-01, subcategory 16 (electricity), and is a member of the CMEQ. Our technicians install and connect the disconnect as part of installing your heat pump.\u003c\/p\u003e\n\u003ch2\u003eInstalled by AirGreen across Greater Montréal\u003c\/h2\u003e\n\u003cp\u003eWe install and connect the disconnect on every heat pump installation in \u003cstrong\u003eMontréal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. For availability or a quote, call us at \u003ca href=\"tel:+15143162973\"\u003e514 316-2973\u003c\/a\u003e or email \u003ca href=\"mailto:sales@airgreen.ca\"\u003esales@airgreen.ca\u003c\/a\u003e with the format and quantity.\u003c\/p\u003e","brand":"AirGreen","offers":[{"title":"Each","offer_id":67638664560932,"sku":"AG-EL-00101","price":0.0,"currency_code":"CAD","in_stock":true},{"title":"Pack of 10","offer_id":67638664593700,"sku":"AG-EL-00102","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/AG-EL-001_00_principale.png?v=1791985667"},{"product_id":"cable-de-communication-14-4-pour-thermopompe","title":"14\/4 Communication Cable for Heat Pumps","description":"\u003cp\u003eThe \u003cstrong\u003e14\/4 communication cable\u003c\/strong\u003e has \u003cstrong\u003e4 conductors of 14 gauge\u003c\/strong\u003e. On a \u003cstrong\u003ewall-mounted heat pump\u003c\/strong\u003e or a \u003cstrong\u003emulti-zone\u003c\/strong\u003e system head, it connects the \u003cstrong\u003eoutdoor unit\u003c\/strong\u003e to the \u003cstrong\u003eindoor unit\u003c\/strong\u003e: it powers the indoor unit and carries communication between the two, according to the manufacturer’s wiring diagram.\u003c\/p\u003e\n\u003ch2\u003eA single cable between the two units\u003c\/h2\u003e\n\u003cp\u003eOn most wall-mounted heat pumps, the main power supply comes in at the outdoor unit. An interconnecting cable then runs to the indoor unit, along with the refrigerant lines and the drain, through the wall opening. That cable is how the two units talk to each other: set point, mode, defrost, error codes. The wrong cable, or a poorly connected one, causes communication errors that are hard to diagnose.\u003c\/p\u003e\n\u003ch3\u003eFollow the unit’s manual\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe heat pump’s \u003cstrong\u003einstallation manual\u003c\/strong\u003e specifies the required number of conductors and gauge.\u003c\/li\u003e\n\u003cli\u003eThe conductors connect to the \u003cstrong\u003enumbered terminal blocks\u003c\/strong\u003e on each unit, in the same order.\u003c\/li\u003e\n\u003cli\u003ePart of the cable runs outdoors: it must be rated for that use.\u003c\/li\u003e\n\u003cli\u003eWhen replacing equipment, the old cable can only be reused if it is in good condition and suitable for the new unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eA job for an electrician\u003c\/h3\u003e\n\u003cp\u003eElectrical connections are reserved for an electrical contractor. AirGreen holds RBQ licence 5645-9605-01, subcategory 16 (electrical), and is a member of the CMEQ. Our technicians run and connect the cable as part of your heat pump installation.\u003c\/p\u003e\n\u003ch2\u003eInstalled by AirGreen in Greater Montréal\u003c\/h2\u003e\n\u003cp\u003eWe run the interconnecting cable on every heat pump installation in \u003cstrong\u003eMontréal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. For availability or a quote, call us at \u003ca href=\"tel:+15143162973\"\u003e514 316-2973\u003c\/a\u003e or email \u003ca href=\"mailto:sales@airgreen.ca\"\u003esales@airgreen.ca\u003c\/a\u003e with the length and quantity.\u003c\/p\u003e","brand":"AirGreen","offers":[{"title":"Default Title","offer_id":67638664626468,"sku":"AG-EL-002","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/AG-EL-002_00_principale.png?v=1791985731"},{"product_id":"fil-electrique-en-cuivre","title":"Copper Electrical Wire","description":"\u003cp\u003e\u003cstrong\u003eCopper electrical wire\u003c\/strong\u003e is offered in \u003cstrong\u003e8, 10, 12 and 14 gauge\u003c\/strong\u003e. It is used for the supply circuits of heating and cooling equipment: \u003cstrong\u003eheat pumps\u003c\/strong\u003e, electric furnaces, heating elements and air exchangers.\u003c\/p\u003e\n\u003ch2\u003eA circuit sized for the unit\u003c\/h2\u003e\n\u003cp\u003eEvery unit shows its electrical ratings on its \u003cstrong\u003enameplate\u003c\/strong\u003e. Based on those ratings, the circuit protection and the length of the run, the electrician determines the wire gauge according to the \u003cstrong\u003eQuébec Construction Code, Chapter V – Electricity\u003c\/strong\u003e. A wire that is too small heats up; an undersized circuit trips the breaker or does not meet the Code.\u003c\/p\u003e\n\u003ch3\u003eFour gauges\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e8 gauge\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e10 gauge\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e12 gauge\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e14 gauge\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe gauge number works in reverse: the smaller it is, the larger the conductor. An 8 gauge wire is therefore larger than a 14 gauge wire.\u003c\/p\u003e\n\u003ch3\u003eReplacing a unit means reviewing the circuit\u003c\/h3\u003e\n\u003cp\u003eSwitching from an air conditioner to a heat pump, or adding a heating element, often changes the electrical requirements. Existing wiring can only be reused if it suits the new unit. Electrical connection is reserved for an electrical contractor. AirGreen holds RBQ licence 5645-9605-01, subcategory 16 (electricity), and is a member of the CMEQ.\u003c\/p\u003e\n\u003ch2\u003eConnected by AirGreen across Greater Montréal\u003c\/h2\u003e\n\u003cp\u003eOur technicians make the electrical connection as part of installing your heat pump or heating equipment in \u003cstrong\u003eMontréal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. For availability or a quote, call us at \u003ca href=\"tel:+15143162973\"\u003e514 316-2973\u003c\/a\u003e or email \u003ca href=\"mailto:sales@airgreen.ca\"\u003esales@airgreen.ca\u003c\/a\u003e with the gauge and length.\u003c\/p\u003e","brand":"AirGreen","offers":[{"title":"8 gauge","offer_id":67638664659236,"sku":"AG-EL-00301","price":0.0,"currency_code":"CAD","in_stock":true},{"title":"10 gauge","offer_id":67638664692004,"sku":"AG-EL-00302","price":0.0,"currency_code":"CAD","in_stock":true},{"title":"12 gauge","offer_id":67638664724772,"sku":"AG-EL-00303","price":0.0,"currency_code":"CAD","in_stock":true},{"title":"14 gauge","offer_id":67638664757540,"sku":"AG-EL-00304","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/AG-EL-003_00_principale.png?v=1791985731"},{"product_id":"disjoncteur-siemens","title":"Breaker for Residential Electrical Panel","description":"\u003cp\u003eThis \u003cstrong\u003ebreaker for a residential electrical panel\u003c\/strong\u003e comes in three models: \u003cstrong\u003esingle-pole 15 A\u003c\/strong\u003e, \u003cstrong\u003esingle-pole 20 A\u003c\/strong\u003e and \u003cstrong\u003etwin\u003c\/strong\u003e. It protects an appliance’s circuit against overcurrent and is installed in the home’s electrical panel.\u003c\/p\u003e\n\u003ch2\u003eThe right breaker for the right circuit\u003c\/h2\u003e\n\u003cp\u003eWhen a heating or cooling appliance is installed, a circuit often has to be added to the panel. The \u003cstrong\u003esingle-pole\u003c\/strong\u003e models protect 120 V circuits: condensate pump, air exchanger, fan or other auxiliary appliance. Most \u003cstrong\u003eheat pumps\u003c\/strong\u003e, on the other hand, run on 240 V and need a \u003cstrong\u003edouble-pole\u003c\/strong\u003e breaker, whose rating is shown on the appliance’s \u003cstrong\u003enameplate\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eSingle-pole or twin\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSingle-pole 15 A or 20 A\u003c\/strong\u003e: one 120 V circuit; the rating matches the appliance and the wire.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eTwin\u003c\/strong\u003e: two single-pole circuits in the space of one breaker, useful when the panel is short on space and accepts this type.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible with your panel\u003c\/h3\u003e\n\u003cp\u003eA breaker must be of a type recognized for the panel it goes into. The panel label lists the accepted types and, for twin models, the permitted positions. Send us a photo of the label: we confirm compatibility before ordering. Electrical connection is reserved for an electrical contractor. AirGreen holds RBQ licence 5645-9605-01, subcategory 16 (electricity), and is a member of the CMEQ.\u003c\/p\u003e\n\u003ch2\u003eInstalled by AirGreen across Greater Montréal\u003c\/h2\u003e\n\u003cp\u003eOur technicians add or replace the breaker as part of installing your heat pump or heating appliance in \u003cstrong\u003eMontréal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. For availability or a quote, call us at \u003ca href=\"tel:+15143162973\"\u003e514 316-2973\u003c\/a\u003e or email \u003ca href=\"mailto:sales@airgreen.ca\"\u003esales@airgreen.ca\u003c\/a\u003e with the model, your panel’s brand and the quantity.\u003c\/p\u003e","brand":"AirGreen","offers":[{"title":"Single-pole 15 A","offer_id":67638664790308,"sku":"AG-EL-00401","price":0.0,"currency_code":"CAD","in_stock":true},{"title":"Single-pole 20 A","offer_id":67638664823076,"sku":"AG-EL-00402","price":0.0,"currency_code":"CAD","in_stock":true},{"title":"Twin","offer_id":67638664855844,"sku":"AG-EL-00403","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/AG-EL-004_00_principale.png?v=1791985730"},{"product_id":"parasurtenseur-pour-appareil-de-cvc-20-ka","title":"Surge Protector for HVAC Equipment – 20 kA","description":"\u003cp\u003eThis \u003cstrong\u003e20 kA\u003c\/strong\u003e \u003cstrong\u003esurge protector for HVAC equipment\u003c\/strong\u003e is installed on the electrical circuit of a \u003cstrong\u003eheat pump\u003c\/strong\u003e or air conditioner, most often at the outdoor disconnect, right next to the unit. It limits voltage spikes coming in through the power supply before they reach the unit's circuit board.\u003c\/p\u003e\n\u003ch2\u003eWhy protect a heat pump against surges\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eVariable-speed\u003c\/strong\u003e (inverter) heat pumps are run by circuit boards. A storm, a power outage or a switching operation on the grid can send a voltage spike that damages this board or the compressor module. Replacing a board puts the unit out of service, sometimes in the middle of winter. A surge protector installed at the unit reduces this risk, in addition to whole-house protection at the electrical panel.\u003c\/p\u003e\n\u003ch3\u003eWhere and how it is installed\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOn the unit's circuit, usually at the \u003cstrong\u003eoutdoor disconnect\u003c\/strong\u003e.\u003c\/li\u003e\n\u003cli\u003eConnected by qualified personnel, in accordance with the Québec Electrical Code.\u003c\/li\u003e\n\u003cli\u003eSurge protector voltage chosen to match the unit's voltage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat it does not do\u003c\/h3\u003e\n\u003cp\u003eA surge protector limits transient overvoltages; it does not protect against a direct lightning strike or against poor grounding. Before installation, we check the voltage, the circuit and the model of your unit.\u003c\/p\u003e\n\u003ch2\u003eInstalled by AirGreen in Greater Montréal\u003c\/h2\u003e\n\u003cp\u003eWe can add it when installing your heat pump or during a service visit in \u003cstrong\u003eMontréal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. RBQ licence 5645-9605-01. For availability or a quote, call us at \u003ca href=\"tel:+15143162973\"\u003e514 316-2973\u003c\/a\u003e or email \u003ca href=\"mailto:sales@airgreen.ca\"\u003esales@airgreen.ca\u003c\/a\u003e with the brand and model of your unit.\u003c\/p\u003e","brand":"AirGreen","offers":[{"title":"Default Title","offer_id":67638665707812,"sku":"AG-EL-005","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/AG-EL-005_00_principale.png?v=1791985730"},{"product_id":"dispositif-de-suppression-de-surtension-rsh50","title":"RectorSeal RSH-50 Surge Protective Device","description":"\u003cp\u003eThe \u003cstrong\u003eRSH-50\u003c\/strong\u003e from \u003cstrong\u003eRectorSeal\u003c\/strong\u003e is a \u003cstrong\u003esurge protective device\u003c\/strong\u003e (surge protector) for single-phase \u003cstrong\u003e120\/240 V AC\u003c\/strong\u003e equipment. It protects air conditioners, \u003cstrong\u003eheat pumps\u003c\/strong\u003e and ductless wall-mounted heat pumps against transient surges, whether they come from a storm or from the grid.\u003c\/p\u003e\n\u003ch2\u003eCertified protection, mounted at the unit\u003c\/h2\u003e\n\u003cp\u003eThe RSH-50 mounts with a \u003cstrong\u003e1\/2 in nipple\u003c\/strong\u003e into a knockout on the disconnect or the unit, on the outdoor unit as well as on the indoor air handler. RectorSeal combines a gas discharge tube (GDT) and thermally fused varistors (TFMOV). A \u003cstrong\u003egreen light\u003c\/strong\u003e shows that protection is active.\u003c\/p\u003e\n\u003ch3\u003eManufacturer specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum discharge current: 50 kA\u003c\/li\u003e\n\u003cli\u003eShort-circuit current rating: 200 kA\u003c\/li\u003e\n\u003cli\u003eMaximum continuous operating voltage: 150 V AC line-to-ground, 300 V AC line-to-line\u003c\/li\u003e\n\u003cli\u003eUL 1449 Type 1 listing, NEMA 4X enclosure, 50\/60 Hz\u003c\/li\u003e\n\u003cli\u003eManufacturer's limited lifetime warranty on the product\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOn its own or with a disconnect\u003c\/h3\u003e\n\u003cp\u003eThe RSH-50 is available on its own, for a disconnect that is already in place, or in a version with a disconnect that combines shutoff and protection. It is designed for single-phase equipment; a three-phase unit needs a different model. The connection must be made by qualified personnel, in accordance with the Electrical Code.\u003c\/p\u003e\n\u003ch2\u003eInstalled by AirGreen in Greater Montréal\u003c\/h2\u003e\n\u003cp\u003eWe add it when installing your heat pump or during a service visit in \u003cstrong\u003eMontréal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. RBQ licence 5645-9605-01. For availability or a quote, call us at \u003ca href=\"tel:+15143162973\"\u003e514 316-2973\u003c\/a\u003e or email \u003ca href=\"mailto:sales@airgreen.ca\"\u003esales@airgreen.ca\u003c\/a\u003e with the version (on its own or with a disconnect) and the model of your unit.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Without disconnect","offer_id":67638665740580,"sku":"AG-EL-00601","price":0.0,"currency_code":"CAD","in_stock":true},{"title":"With disconnect","offer_id":67638665773348,"sku":"AG-EL-00602","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/AG-EL-006_00_principale.png?v=1791985730"}],"url":"https:\/\/airgreen.ca\/en\/collections\/electricite.oembed","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}