{"title":"ELIOS Extra-Slim Fan Coil Unit (Pancake) Heat Pump | Montreal, Laval, Longueuil, South Shore, North Shore","description":"","products":[{"product_id":"ventilo-convecteur-extra-plat-de-thermopompe-elios-18-000-btu","title":"ELIOS Extra-Slim (Pancake) Heat Pump Fan Coil Unit | 18,000 BTU","description":"\u003ch2 data-start=\"94\" data-end=\"182\"\u003e An HVAC approach designed for real buildings, not for theoretical catalogs.\u003c\/h2\u003e\n\n\u003cp data-start=\"184\" data-end=\"743\"\u003e At AirGreen, we never choose HVAC equipment based solely on marketing figures. Every product we offer must meet very real constraints encountered daily in the field in \u003cstrong data-start=\"417\" data-end=\"429\"\u003eMontreal\u003c\/strong\u003e , \u003cstrong data-start=\"431\" data-end=\"440\"\u003eLaval\u003c\/strong\u003e , \u003cstrong data-start=\"442\" data-end=\"455\"\u003eLongueuil\u003c\/strong\u003e , and on the \u003cstrong data-start=\"464\" data-end=\"477\"\u003eNorth\u003c\/strong\u003e and \u003cstrong data-start=\"484\" data-end=\"496\"\u003eSouth Shores\u003c\/strong\u003e . The \u003cstrong data-start=\"501\" data-end=\"576\"\u003eELIOS 18,000 BTU ultra-slim (pancake) fan coil unit for heat pumps\u003c\/strong\u003e fits perfectly into this philosophy: a solution designed for modern buildings, complex renovations, and projects where every available inch counts.\u003c\/p\u003e\n\n \u003cp data-start=\"745\" data-end=\"1182\"\u003eThis type of fan coil unit is designed for property owners and managers facing low ceilings, limited technical spaces, strict architectural constraints, or high aesthetic requirements. Unlike a standard fan coil unit, the pancake format allows for discreet integration without sacrificing energy efficiency, stable heating in winter, or cooling comfort.\u003c\/p\u003e\n\n\u003cp data-start=\"1184\" data-end=\"1421\"\u003e In many recent projects, including concrete-framed condos or renovated multiplexes, this format has become not only an advantage, but often the only viable option for a \u003cstrong data-start=\"1379\" data-end=\"1420\"\u003ecompliant and sustainable HVAC installation\u003c\/strong\u003e .\u003c\/p\u003e\n\n\u003ch2 data-start=\"1423\" data-end=\"1478\"\u003e Thermal performance adapted to the Quebec climate\u003c\/h2\u003e\n\n \u003cp data-start=\"1480\" data-end=\"1817\"\u003eThe ELIOS 18,000 BTU model is not only compact, but also designed to operate efficiently in demanding climates. In heating mode, the associated heat pump maintains operational capacity down to \u003cstrong data-start=\"1715\" data-end=\"1725\"\u003e-25°C\u003c\/strong\u003e , a crucial feature for the harsh winters we regularly experience in Quebec.\u003c\/p\u003e\n\n\u003cp data-start=\"1819\" data-end=\"1857\"\u003e In real-world conditions, this means: \u003c\/p\u003e\n\n\u003cul data-start=\"1858\" data-end=\"2162\"\u003e\n\n\u003cli data-start=\"1858\" data-end=\"1932\"\u003e\n\n\u003cp data-start=\"1860\" data-end=\"1932\"\u003e A \u003cstrong data-start=\"1864\" data-end=\"1899\"\u003enominal capacity of 18,000 BTU\u003c\/strong\u003e in air conditioning and heating \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1933\" data-end=\"2009\"\u003e\n\n\u003cp data-start=\"1935\" data-end=\"2009\"\u003e Stable performance down to \u003cstrong data-start=\"1960\" data-end=\"1969\"\u003e-8°C\u003c\/strong\u003e with approximately \u003cstrong data-start=\"1983\" data-end=\"2009\"\u003e11,800 BTUs available\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2010\" data-end=\"2082\"\u003e\n\n\u003cp data-start=\"2012\" data-end=\"2082\"\u003e A capacity still usable at \u003cstrong data-start=\"2046\" data-end=\"2056\"\u003e-15°C\u003c\/strong\u003e , around \u003cstrong data-start=\"2068\" data-end=\"2082\"\u003e11,400 BTU\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2083\" data-end=\"2162\"\u003e\n\n\u003cp data-start=\"2085\" data-end=\"2162\"\u003e Consistent energy efficiency, limiting the need for backup systems\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"2164\" data-end=\"2375\"\u003eFor homeowners, this stability translates into a constant indoor temperature, fewer start-up cycles, and better controlled energy consumption, especially in well-insulated homes.\u003c\/p\u003e\n\n\u003cp data-start=\"2377\" data-end=\"2670\"\u003e In air conditioning, a \u003cstrong data-start=\"2410\" data-end=\"2450\"\u003edehumidification capacity of approximately 1.46 L\/h\u003c\/strong\u003e plays a key role in summer comfort. In Montreal and Laval, where summer humidity is often more uncomfortable than the heat itself, this parameter makes a real difference in the perceived temperature.\u003c\/p\u003e\n\n\u003ch2 data-start=\"2672\" data-end=\"2727\"\u003e An ultra-slim design that changes the way you install\u003c\/h2\u003e\n\n\u003cp data-start=\"2729\" data-end=\"2955\"\u003e The main advantage of the ELIOS pancake fan coil unit lies in its \u003cstrong data-start=\"2800\" data-end=\"2848\"\u003eextremely compact internal dimensions\u003c\/strong\u003e , while still maintaining an airflow rate suitable for the areas it serves. This format allows for integration into: \u003c\/p\u003e\n\n\u003cul data-start=\"2956\" data-end=\"3114\"\u003e\n\n\u003cli data-start=\"2956\" data-end=\"2993\"\u003e\n\n\u003cp data-start=\"2958\" data-end=\"2993\"\u003e Very shallow false ceilings \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2994\" data-end=\"3028\"\u003e\n\n\u003cp data-start=\"2996\" data-end=\"3028\"\u003e Narrow technical corridors \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3029\" data-end=\"3057\"\u003e\n\n\u003cp data-start=\"3031\" data-end=\"3057\"\u003e Mechanical wardrobes\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3058\" data-end=\"3114\"\u003e\n\n \u003cp data-start=\"3060\" data-end=\"3114\"\u003eSpaces above bathrooms or kitchens\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"3116\" data-end=\"3559\"\u003e In the field, we installed this model in downtown Montreal condos where the available ceiling height was less than 12 inches. Without this type of unit, the client would have had to accept a major modification to the ceiling structure, with significant additional costs. In Longueuil, in a renovated triplex, the pancake format allowed for a complete modernization of the HVAC system without altering the existing finishes.\u003c\/p\u003e\n\n\u003cp data-start=\"3561\" data-end=\"3806\"\u003e This type of configuration also offers an acoustic advantage: the discreet positioning and internal design help to limit the propagation of noise, which is particularly appreciated in bedrooms and home offices.\u003c\/p\u003e\n\n\u003ch2 data-start=\"3808\" data-end=\"3860\"\u003e Airflow, room balance, and real comfort\u003c\/h2\u003e\n\n \u003cp data-start=\"3862\" data-end=\"4151\"\u003eEven a compact fan coil unit must ensure consistent air distribution. The ELIOS 18,000 BTU model offers several fan speeds, allowing for precise adjustments to suit your home's layout. At AirGreen, we pay particular attention to: \u003c\/p\u003e\n\n\u003cul data-start=\"4152\" data-end=\"4271\"\u003e\n\n\u003cli data-start=\"4152\" data-end=\"4180\"\u003e\n\n\u003cp data-start=\"4154\" data-end=\"4180\"\u003e Balancing the conduits \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4181\" data-end=\"4215\"\u003e\n\n\u003cp data-start=\"4183\" data-end=\"4215\"\u003e The homogeneous distribution of air \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4216\" data-end=\"4271\"\u003e\n\n\u003cp data-start=\"4218\" data-end=\"4271\"\u003e Avoiding overheated or undercooled areas\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"4273\" data-end=\"4483\"\u003e In open areas, very common on the South Shore and in recent constructions in Laval, this control of airflow is essential to maintain uniform comfort without unpleasant drafts.\u003c\/p\u003e\n\n\u003ch2 data-start=\"4485\" data-end=\"4549\"\u003e HVAC Installation: What Field Experience Has Taught Us\u003c\/h2\u003e\n\n\u003cp data-start=\"4551\" data-end=\"4779\"\u003e Installing an ultra-slim fan coil unit isn't simply a matter of fitting it into a tight space. A successful HVAC installation relies on a series of technical checks that our teams systematically perform: \u003c\/p\u003e\n\n\u003cul data-start=\"4780\" data-end=\"5168\"\u003e\n\n\u003cli data-start=\"4780\" data-end=\"4861\"\u003e\n\n \u003cp data-start=\"4782\" data-end=\"4861\"\u003eValidation of the \u003cstrong data-start=\"4799\" data-end=\"4831\"\u003eavailable static pressure\u003c\/strong\u003e to ensure optimal flow rate \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4862\" data-end=\"4932\"\u003e\n\n\u003cp data-start=\"4864\" data-end=\"4932\"\u003e Precise sizing of conduits to avoid pressure losses \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4933\" data-end=\"5025\"\u003e\n\n\u003cp data-start=\"4935\" data-end=\"5025\"\u003e Rigorous management of condensation drainage to prevent any accumulation of moisture \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5026\" data-end=\"5168\"\u003e\n\n\u003cp data-start=\"5028\" data-end=\"5168\"\u003e Strategic positioning of the outdoor unit, with \u003cstrong data-start=\"5083\" data-end=\"5108\"\u003eadequate elevation\u003c\/strong\u003e to prevent problems related to snow and defrosting.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"5170\" data-end=\"5461\"\u003e We have often been called upon to correct existing installations where these elements had been neglected. The result: excessive noise, reduced efficiency, and premature breakdowns. It is precisely this type of situation that we avoid thanks to our methodical approach and local experience.\u003c\/p\u003e\n\n\u003ch2 data-start=\"5463\" data-end=\"5520\"\u003e Primary heating, supplementary heating or energy transition\u003c\/h2\u003e\n\n\u003cp data-start=\"5522\" data-end=\"5617\"\u003e The ELIOS 18,000 BTU pancake fan coil unit can fulfill several roles depending on the building: \u003c\/p\u003e\n\n\u003cul data-start=\"5618\" data-end=\"5869\"\u003e\n\n\u003cli data-start=\"5618\" data-end=\"5685\"\u003e\n\n \u003cp data-start=\"5620\" data-end=\"5685\"\u003e\u003cstrong data-start=\"5620\" data-end=\"5654\"\u003ePrimary source of heating\u003c\/strong\u003e in well-insulated homes \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5686\" data-end=\"5756\"\u003e\n\n\u003cp data-start=\"5688\" data-end=\"5756\"\u003e \u003cstrong data-start=\"5688\" data-end=\"5708\"\u003eHybrid solution\u003c\/strong\u003e , combined with existing electric baseboard heaters \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5757\" data-end=\"5869\"\u003e\n\n\u003cp data-start=\"5759\" data-end=\"5869\"\u003e \u003cstrong data-start=\"5759\" data-end=\"5794\"\u003eA step in the energy transition\u003c\/strong\u003e , to gradually reduce reliance on direct electric heating\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"5871\" data-end=\"6102\"\u003e In some projects, particularly older buildings on the North Shore, the addition of this type of HVAC system already allows for a significant reduction in energy bills, even without completely eliminating existing systems.\u003c\/p\u003e\n\n\u003cp data-start=\"6104\" data-end=\"6390\"\u003e Integrated electric heating options can be considered depending on specific needs, but only after a detailed analysis of the heat load. At AirGreen, we systematically avoid oversizing, a frequent source of excessive energy consumption and discomfort.\u003c\/p\u003e\n\n\u003ch2 data-start=\"6392\" data-end=\"6437\"\u003e LogisVert subsidy and financial logic\u003c\/h2\u003e\n\n \u003cp data-start=\"6439\" data-end=\"6715\"\u003eThis model is eligible for the \u003cstrong data-start=\"6469\" data-end=\"6505\"\u003eLogisVert provincial grant\u003c\/strong\u003e , with an indicative amount of \u003cstrong data-start=\"6536\" data-end=\"6545\"\u003e$590\u003c\/strong\u003e , subject to applicable criteria. For many clients in Montreal, Laval, and Longueuil, this assistance significantly reduces the initial project cost.\u003c\/p\u003e\n\n\u003cp data-start=\"6717\" data-end=\"6814\"\u003e Combined with optimized installation and proper use, this heat pump often allows: \u003c\/p\u003e\n\n\u003cul data-start=\"6815\" data-end=\"6994\"\u003e\n\n\u003cli data-start=\"6815\" data-end=\"6866\"\u003e\n\n\u003cp data-start=\"6817\" data-end=\"6866\"\u003e A gradual decrease in heating costs \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6867\" data-end=\"6922\"\u003e\n\n\u003cp data-start=\"6869\" data-end=\"6922\"\u003e Improved predictability of energy expenditures \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6923\" data-end=\"6994\"\u003e\n\n\u003cp data-start=\"6925\" data-end=\"6994\"\u003e An increase in the building's value, particularly in the rental market.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch2 data-start=\"6996\" data-end=\"7046\"\u003e Reliability, maintenance and long-term durability\u003c\/h2\u003e\n\n\u003cp data-start=\"7048\" data-end=\"7321\"\u003e The reliability of an HVAC system depends not only on the product itself, but also on the quality of the installation and maintenance. The ELIOS fan coil unit comes with a basic warranty covering the compressor and parts, with optional extensions available.\u003c\/p\u003e\n\n \u003cp data-start=\"7323\" data-end=\"7404\"\u003eAt AirGreen, we emphasize the importance of \u003cstrong data-start=\"7375\" data-end=\"7402\"\u003eregular HVAC maintenance\u003c\/strong\u003e : \u003c\/p\u003e\n\n\u003cul data-start=\"7405\" data-end=\"7550\"\u003e\n\n\u003cli data-start=\"7405\" data-end=\"7444\"\u003e\n\n\u003cp data-start=\"7407\" data-end=\"7444\"\u003e Cleaning and replacing the filters \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7445\" data-end=\"7497\"\u003e\n\n\u003cp data-start=\"7447\" data-end=\"7497\"\u003e Annual verification of speeds and connections \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7498\" data-end=\"7550\"\u003e\n\n\u003cp data-start=\"7500\" data-end=\"7550\"\u003e Preventive inspection before the heating season\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"7552\" data-end=\"7763\"\u003e We observe in the field that properly maintained systems retain stable performance over many years, even in harsh climatic conditions like those of the North Shore.\u003c\/p\u003e\n\n\u003ch2 data-start=\"7765\" data-end=\"7808\"\u003e Why entrust your project to AirGreen\u003c\/h2\u003e\n\n\u003cp data-start=\"7810\" data-end=\"7893\"\u003e Choosing AirGreen is not simply buying equipment. It's benefiting from: \u003c\/p\u003e\n\n\u003cul data-start=\"7894\" data-end=\"8203\"\u003e\n\n\u003cli data-start=\"7894\" data-end=\"7972\"\u003e\n\n\u003cp data-start=\"7896\" data-end=\"7972\"\u003e With \u003cstrong data-start=\"7902\" data-end=\"7932\"\u003eproven field expertise\u003c\/strong\u003e in hundreds of HVAC installations \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7973\" data-end=\"8045\"\u003e\n\n\u003cp data-start=\"7975\" data-end=\"8045\"\u003e \u003cstrong data-start=\"7978\" data-end=\"8009\"\u003eClear and transparent pricing\u003c\/strong\u003e , confirmed before work begins \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"8046\" data-end=\"8098\"\u003e\n\n\u003cp data-start=\"8048\" data-end=\"8098\"\u003e \u003cstrong data-start=\"8054\" data-end=\"8098\"\u003e$5 million in liability insurance\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"8099\" data-end=\"8203\"\u003e\n\n \u003cp data-start=\"8101\" data-end=\"8203\"\u003eTechnical support tailored to the realities of Montreal, Laval, Longueuil, the North Shore and the South Shore\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"8205\" data-end=\"8349\"\u003e We analyze each project as a unique case, with recommendations based on real situations, not on generic assumptions.\u003c\/p\u003e\n\n\u003ch2 data-start=\"8351\" data-end=\"8384\"\u003e Conclusion\u003c\/h2\u003e\n\n\u003cp data-start=\"8386\" data-end=\"8768\"\u003e The \u003cstrong data-start=\"8389\" data-end=\"8464\"\u003eELIOS 18,000 BTU ultra-slim (pancake) fan coil unit\u003c\/strong\u003e is a well-considered HVAC solution for projects where space, comfort, and energy efficiency must coexist without compromise. When properly installed, it offers reliable performance, quiet operation, and clean architectural integration, perfectly suited to Quebec buildings.\u003c\/p\u003e\n\n \u003cp data-start=\"8770\" data-end=\"9040\"\u003eTo obtain a \u003cstrong data-start=\"8787\" data-end=\"8811\"\u003edetailed quote\u003c\/strong\u003e , check your eligibility for the \u003cstrong data-start=\"8843\" data-end=\"8867\"\u003eLogisVert grant\u003c\/strong\u003e , or discuss your \u003cstrong data-start=\"8898\" data-end=\"8919\"\u003eHVAC installation\u003c\/strong\u003e project, contact AirGreen directly. Our team will guide you through every step with diligence, transparency, and expertise.\u003c\/p\u003e","brand":"ELIOS","offers":[{"title":"Default Title","offer_id":51954112200996,"sku":"GPHLA18R4AS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/Extra-flatfancoilconvector_Pancake_-ELIOS.png?v=1769969064"},{"product_id":"ventilo-convecteur-extra-plat-de-thermopompe-elios-24-000-btu","title":"ELIOS Extra-Slim (Pancake) Heat Pump Fan Coil Unit | 24,000 BTU","description":"\u003ch2 data-start=\"94\" data-end=\"183\"\u003e An ultra-slim HVAC solution designed for the most demanding projects in Quebec\u003c\/h2\u003e\n\n\u003cp data-start=\"185\" data-end=\"691\"\u003e At \u003cstrong data-start=\"190\" data-end=\"242\"\u003eAirGreen Heat Pumps, Air Conditioning \u0026amp; Heating\u003c\/strong\u003e , we work daily on projects where available space, architectural constraints, and performance requirements leave no room for error. The \u003cstrong data-start=\"428\" data-end=\"488\"\u003eELIOS 24,000 BTU ultra-slim (pancake) fan coil unit\u003c\/strong\u003e falls precisely into this category of HVAC solutions designed to meet the realities encountered in \u003cstrong data-start=\"611\" data-end=\"623\"\u003eMontreal\u003c\/strong\u003e , \u003cstrong data-start=\"625\" data-end=\"634\"\u003eLaval\u003c\/strong\u003e , \u003cstrong data-start=\"636\" data-end=\"649\"\u003eLongueuil\u003c\/strong\u003e , and on the \u003cstrong data-start=\"658\" data-end=\"671\"\u003eNorth\u003c\/strong\u003e and \u003cstrong data-start=\"678\" data-end=\"690\"\u003eSouth Shores\u003c\/strong\u003e .\u003c\/p\u003e\n\n \u003cp data-start=\"693\" data-end=\"1037\"\u003eThis type of unit is not suitable for all projects. It is aimed at owners, property managers and professionals who are looking for discreet integration, reliable thermal performance in cold climates and greater installation flexibility than traditional wall systems or complete ductwork systems.\u003c\/p\u003e\n\n\u003chr data-start=\"1039\" data-end=\"1042\"\u003e\n\n\u003ch2 data-start=\"1044\" data-end=\"1117\"\u003e The \"Pancake\" concept: a clever response to space limitations\u003c\/h2\u003e\n\n\u003ch3 data-start=\"1119\" data-end=\"1179\"\u003e An ultra-slim profile that opens up new possibilities\u003c\/h3\u003e\n\n\u003cp data-start=\"1180\" data-end=\"1396\"\u003e With a height of less than 11 inches, the \u003cstrong data-start=\"1240\" data-end=\"1256\"\u003eGPHLA24R4AS1\u003c\/strong\u003e indoor unit allows for installation configurations often impossible with conventional fan coil units. In practice, this means: \u003c\/p\u003e\n\n\u003cul data-start=\"1397\" data-end=\"1704\"\u003e\n\n\u003cli data-start=\"1397\" data-end=\"1463\"\u003e\n\n\u003cp data-start=\"1399\" data-end=\"1463\"\u003e Direct integration into \u003cstrong data-start=\"1432\" data-end=\"1462\"\u003enarrow suspended ceilings\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1464\" data-end=\"1567\"\u003e\n\n\u003cp data-start=\"1466\" data-end=\"1567\"\u003e An installation above corridors, kitchens or bathrooms without lowering the ceilings,\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1568\" data-end=\"1704\"\u003e\n\n \u003cp data-start=\"1570\" data-end=\"1704\"\u003eAn ideal fit for \u003cstrong data-start=\"1596\" data-end=\"1615\"\u003emodern condos\u003c\/strong\u003e , \u003cstrong data-start=\"1621\" data-end=\"1637\"\u003erenovated plexes\u003c\/strong\u003e and \u003cstrong data-start=\"1645\" data-end=\"1670\"\u003ecommercial buildings\u003c\/strong\u003e where mechanical space is limited.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"1706\" data-end=\"1901\"\u003e We have notably used this format in buildings in downtown \u003cstrong data-start=\"1777\" data-end=\"1789\"\u003eMontreal\u003c\/strong\u003e , where preserving clear heights was a non-negotiable requirement imposed by the existing architecture.\u003c\/p\u003e\n\n\u003ch3 data-start=\"1903\" data-end=\"1965\"\u003e A solution designed for both aesthetics and functionality\u003c\/h3\u003e\n\n \u003cp data-start=\"1966\" data-end=\"2311\"\u003eUnlike some compact systems that compromise airflow, the ELIOS Pancake maintains an effective balance between \u003cstrong data-start=\"2104\" data-end=\"2127\"\u003ea small footprint\u003c\/strong\u003e and \u003cstrong data-start=\"2131\" data-end=\"2157\"\u003econtrolled distribution\u003c\/strong\u003e . The grilles can be strategically positioned, reducing cold or overheated areas and improving overall occupant comfort.\u003c\/p\u003e\n\n\u003chr data-start=\"2313\" data-end=\"2316\"\u003e\n\n\u003ch2 data-start=\"2318\" data-end=\"2370\"\u003e Controlled air distribution and indoor comfort\u003c\/h2\u003e\n\n\u003ch3 data-start=\"2372\" data-end=\"2416\"\u003e Airflow adapted to complex spaces\u003c\/h3\u003e\n\n\u003cp data-start=\"2417\" data-end=\"2620\"\u003e With an airflow of up to \u003cstrong data-start=\"2449\" data-end=\"2460\"\u003e824 CFM\u003c\/strong\u003e , the system provides sufficient air circulation to serve multiple zones from a single unit. This capacity is particularly useful in: \u003c\/p\u003e\n\n\u003cul data-start=\"2621\" data-end=\"2774\"\u003e\n\n\u003cli data-start=\"2621\" data-end=\"2655\"\u003e\n\n\u003cp data-start=\"2623\" data-end=\"2655\"\u003e Open-plan apartments, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2656\" data-end=\"2685\"\u003e\n\n\u003cp data-start=\"2658\" data-end=\"2685\"\u003e Professional offices, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2686\" data-end=\"2774\"\u003e\n\n\u003cp data-start=\"2688\" data-end=\"2774\"\u003e Light commercial premises requiring a stable temperature across the entire surface.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"2776\" data-end=\"2941\"\u003eThe available static pressure facilitates the use of short, well-sized conduits, which reduces losses and improves the overall efficiency of the system.\u003c\/p\u003e\n\n\u003ch3 data-start=\"2943\" data-end=\"2989\"\u003e Reduced humidity and summer comfort\u003c\/h3\u003e\n\n\u003cp data-start=\"2990\" data-end=\"3175\"\u003e The \u003cstrong data-start=\"3005\" data-end=\"3051\"\u003edehumidification capacity of 4.04 pints per hour\u003c\/strong\u003e plays a key role during the humid summers typical of \u003cstrong data-start=\"3105\" data-end=\"3117\"\u003eMontreal\u003c\/strong\u003e and the \u003cstrong data-start=\"3127\" data-end=\"3139\"\u003eSouth Shore\u003c\/strong\u003e . In practice, this translates to: \u003c\/p\u003e\n\n\u003cul data-start=\"3176\" data-end=\"3326\"\u003e\n\n\u003cli data-start=\"3176\" data-end=\"3217\"\u003e\n\n\u003cp data-start=\"3178\" data-end=\"3217\"\u003e A faster feeling of freshness \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3218\" data-end=\"3247\"\u003e\n\n\u003cp data-start=\"3220\" data-end=\"3247\"\u003e Healthier indoor air, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3248\" data-end=\"3326\"\u003e\n\n\u003cp data-start=\"3250\" data-end=\"3326\"\u003e A reduction in condensation problems in poorly ventilated dwellings. \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003chr data-start=\"3328\" data-end=\"3331\"\u003e\n\n\u003ch2 data-start=\"3333\" data-end=\"3390\"\u003e Heating performance designed for Quebec winters\u003c\/h2\u003e\n\n\u003ch3 data-start=\"3392\" data-end=\"3432\"\u003e Stable operation down to -25°C\u003c\/h3\u003e\n\n \u003cp data-start=\"3433\" data-end=\"3658\"\u003eThe \u003cstrong data-start=\"3452\" data-end=\"3468\"\u003eESHEA24R2AN1\u003c\/strong\u003e outdoor unit is designed to maintain reliable performance in harsh winter conditions. Measured performance demonstrates a genuine heating capacity even when temperatures drop: \u003c\/p\u003e\n\n\u003cul data-start=\"3659\" data-end=\"3738\"\u003e\n\n\u003cli data-start=\"3659\" data-end=\"3684\"\u003e\n\n\u003cp data-start=\"3661\" data-end=\"3684\"\u003e \u003cstrong data-start=\"3661\" data-end=\"3683\"\u003e19,800 BTU at -8°C\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3685\" data-end=\"3711\"\u003e\n\n\u003cp data-start=\"3687\" data-end=\"3711\"\u003e \u003cstrong data-start=\"3687\" data-end=\"3710\"\u003e19,000 BTU at -15°C\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3712\" data-end=\"3738\"\u003e\n\n\u003cp data-start=\"3714\" data-end=\"3738\"\u003e \u003cstrong data-start=\"3714\" data-end=\"3737\"\u003e15,000 BTU at -25°C\u003c\/strong\u003e .\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"3740\" data-end=\"3924\"\u003e In our projects carried out on the \u003cstrong data-start=\"3773\" data-end=\"3786\"\u003eNorth Shore\u003c\/strong\u003e , this stability has made it possible to limit the use of supplementary electricity, while maintaining constant comfort in the living spaces.\u003c\/p\u003e\n\n\u003ch3 data-start=\"3926\" data-end=\"3974\"\u003e Consistent and predictable energy performance\u003c\/h3\u003e\n\n\u003cp data-start=\"3975\" data-end=\"4047\"\u003e The seasonal efficiency values ​​indicate a balanced system: \u003c\/p\u003e\n\n\u003cul data-start=\"4048\" data-end=\"4212\"\u003e\n\n\u003cli data-start=\"4048\" data-end=\"4087\"\u003e\n\n\u003cp data-start=\"4050\" data-end=\"4087\"\u003e \u003cstrong data-start=\"4050\" data-end=\"4064\"\u003eSEER2: 16\u003c\/strong\u003e for air conditioning,\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4088\" data-end=\"4123\"\u003e\n\n \u003cp data-start=\"4090\" data-end=\"4123\"\u003e\u003cstrong data-start=\"4090\" data-end=\"4109\"\u003eHSPF2 up to 9\u003c\/strong\u003e in heating mode, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4124\" data-end=\"4167\"\u003e\n\n\u003cp data-start=\"4126\" data-end=\"4167\"\u003e \u003cstrong data-start=\"4126\" data-end=\"4139\"\u003eEER2: 10\u003c\/strong\u003e in instantaneous performance, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4168\" data-end=\"4212\"\u003e\n\n\u003cp data-start=\"4170\" data-end=\"4212\"\u003e \u003cstrong data-start=\"4170\" data-end=\"4211\"\u003eStable COP even in cold conditions\u003c\/strong\u003e .\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"4214\" data-end=\"4408\"\u003e For our customers, this translates into controlled electricity consumption and better predictability of operating costs, a point often underestimated when choosing an HVAC system.\u003c\/p\u003e\n\n\u003chr data-start=\"4410\" data-end=\"4413\"\u003e\n\n\u003ch2 data-start=\"4415\" data-end=\"4468\"\u003e R-454B refrigerant: a future-proof choice\u003c\/h2\u003e\n\n\u003cp data-start=\"4470\" data-end=\"4604\"\u003e \u003cstrong data-start=\"4473\" data-end=\"4483\"\u003eR-454B\u003c\/strong\u003e represents a significant improvement over older refrigerants. Its use in the ELIOS Pancake allows for: \u003c\/p\u003e\n\n\u003cul data-start=\"4605\" data-end=\"4796\"\u003e\n\n\u003cli data-start=\"4605\" data-end=\"4649\"\u003e\n\n\u003cp data-start=\"4607\" data-end=\"4649\"\u003e A reduction in environmental impact, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4650\" data-end=\"4704\"\u003e\n\n\u003cp data-start=\"4652\" data-end=\"4704\"\u003e Compliance with current and future standards \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4705\" data-end=\"4796\"\u003e\n\n\u003cp data-start=\"4707\" data-end=\"4796\"\u003e Greater peace of mind for owners and managers in the long term.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"4798\" data-end=\"4997\"\u003eIn several commercial projects in \u003cstrong data-start=\"4835\" data-end=\"4844\"\u003eLaval\u003c\/strong\u003e and \u003cstrong data-start=\"4848\" data-end=\"4861\"\u003eLongueuil\u003c\/strong\u003e , this factor weighed heavily in the final decision, particularly for buildings subject to internal environmental policies.\u003c\/p\u003e\n\n\u003chr data-start=\"4999\" data-end=\"5002\"\u003e\n\n\u003ch2 data-start=\"5004\" data-end=\"5073\"\u003e Noise levels suitable for residential and professional environments\u003c\/h2\u003e\n\n\u003cp data-start=\"5075\" data-end=\"5229\"\u003e The internal noise level, between \u003cstrong data-start=\"5117\" data-end=\"5139\"\u003e51.5 and 56.5 dB(A)\u003c\/strong\u003e depending on the operating mode, allows installation in sensitive areas such as: \u003c\/p\u003e\n\n\u003cul data-start=\"5230\" data-end=\"5329\"\u003e\n\n\u003cli data-start=\"5230\" data-end=\"5255\"\u003e\n\n\u003cp data-start=\"5232\" data-end=\"5255\"\u003e The bedrooms, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5256\" data-end=\"5281\"\u003e\n\n\u003cp data-start=\"5258\" data-end=\"5281\"\u003e Workspaces, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5282\" data-end=\"5329\"\u003e\n\n\u003cp data-start=\"5284\" data-end=\"5329\"\u003e The consultation rooms or closed offices.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"5331\" data-end=\"5524\"\u003e During installation, our team pays particular attention to suspension, vibration isolation and balancing of ducts to avoid any long-term noise nuisance.\u003c\/p\u003e\n\n\u003chr data-start=\"5526\" data-end=\"5529\"\u003e\n\n\u003ch2 data-start=\"5531\" data-end=\"5579\"\u003e Installation details that make all the difference\u003c\/h2\u003e\n\n\u003ch3 data-start=\"5581\" data-end=\"5621\"\u003e Electrical and technical parameters\u003c\/h3\u003e\n\n \u003cp data-start=\"5622\" data-end=\"5686\"\u003eThe system operates on a \u003cstrong data-start=\"5665\" data-end=\"5678\"\u003e220–230 V\u003c\/strong\u003e power supply, with: \u003c\/p\u003e\n\n\u003cul data-start=\"5687\" data-end=\"5879\"\u003e\n\n\u003cli data-start=\"5687\" data-end=\"5704\"\u003e\n\n\u003cp data-start=\"5689\" data-end=\"5704\"\u003e \u003cstrong data-start=\"5689\" data-end=\"5703\"\u003eMCA: 19 A\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5705\" data-end=\"5722\"\u003e\n\n\u003cp data-start=\"5707\" data-end=\"5722\"\u003e \u003cstrong data-start=\"5707\" data-end=\"5721\"\u003eMOP: 20 A\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5723\" data-end=\"5788\"\u003e\n\n\u003cp data-start=\"5725\" data-end=\"5788\"\u003e Compatibility with long pipe runs, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5789\" data-end=\"5879\"\u003e\n\n\u003cp data-start=\"5791\" data-end=\"5879\"\u003e Flexible installation in existing buildings without major modifications.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"5881\" data-end=\"6015\"\u003e These features are particularly appreciated in renovation projects where the electrical infrastructure is already in place.\u003c\/p\u003e\n\n\u003ch3 data-start=\"6017\" data-end=\"6062\"\u003e Outdoor installation adapted to the climate\u003c\/h3\u003e\n\n\u003cp data-start=\"6063\" data-end=\"6409\"\u003e For heating, the outdoor unit must be properly elevated to manage snow accumulation and defrost drainage. At \u003cstrong data-start=\"6199\" data-end=\"6211\"\u003eAirGreen\u003c\/strong\u003e , we consistently apply these principles to preserve winter performance and system durability, especially in areas exposed to strong winds and heavy rainfall.\u003c\/p\u003e\n\n\u003chr data-start=\"6411\" data-end=\"6414\"\u003e\n\n \u003ch2 data-start=\"6416\" data-end=\"6471\"\u003eLogisVert subsidy: a concrete financial advantage\u003c\/h2\u003e\n\n\u003cp data-start=\"6473\" data-end=\"6691\"\u003e The \u003cstrong data-start=\"6476\" data-end=\"6523\"\u003eELIOS 24,000 BTU Pancake fan coil unit\u003c\/strong\u003e is eligible for the \u003cstrong data-start=\"6544\" data-end=\"6580\"\u003eLogisVert provincial subsidy\u003c\/strong\u003e , which can reach up to \u003cstrong data-start=\"6600\" data-end=\"6611\"\u003e$2,376\u003c\/strong\u003e depending on the applicable conditions. We support our customers every step of the way: \u003c\/p\u003e\n\n\u003cul data-start=\"6692\" data-end=\"6779\"\u003e\n\n\u003cli data-start=\"6692\" data-end=\"6715\"\u003e\n\n\u003cp data-start=\"6694\" data-end=\"6715\"\u003e Technical validation, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6716\" data-end=\"6744\"\u003e\n\n\u003cp data-start=\"6718\" data-end=\"6744\"\u003e Administrative compliance, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6745\" data-end=\"6779\"\u003e\n\n\u003cp data-start=\"6747\" data-end=\"6779\"\u003e Preparation and monitoring of the file.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"6781\" data-end=\"6885\"\u003e This approach reduces delays and avoids often costly errors in grant applications.\u003c\/p\u003e\n\n\u003chr data-start=\"6887\" data-end=\"6890\"\u003e\n\n\u003ch2 data-start=\"6892\" data-end=\"6937\"\u003e Concrete examples of AirGreen installations\u003c\/h2\u003e\n\n\u003cp data-start=\"6939\" data-end=\"7101\"\u003e In \u003cstrong data-start=\"6941\" data-end=\"6957\"\u003eBoucherville\u003c\/strong\u003e , we installed this system in a multi-unit residential building where mechanical space was extremely limited. After a full season: \u003c\/p\u003e\n\n\u003cul data-start=\"7102\" data-end=\"7265\"\u003e\n\n\u003cli data-start=\"7102\" data-end=\"7165\"\u003e\n\n\u003cp data-start=\"7104\" data-end=\"7165\"\u003e The occupants noted an improvement in thermal comfort. \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7166\" data-end=\"7203\"\u003e\n\n\u003cp data-start=\"7168\" data-end=\"7203\"\u003e Energy costs have decreased,\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7204\" data-end=\"7265\"\u003e\n\n \u003cp data-start=\"7206\" data-end=\"7265\"\u003eNo noise or condensation problems were reported.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"7267\" data-end=\"7475\"\u003e In \u003cstrong data-start=\"7269\" data-end=\"7286\"\u003eMontreal North\u003c\/strong\u003e , the ELIOS Pancake made it possible to efficiently air-condition a commercial space without altering the existing structure, while respecting the aesthetic constraints imposed by the owner.\u003c\/p\u003e\n\n\u003chr data-start=\"7477\" data-end=\"7480\"\u003e\n\n\u003ch2 data-start=\"7482\" data-end=\"7525\"\u003e Why entrust your project to AirGreen\u003c\/h2\u003e\n\n\u003cp data-start=\"7527\" data-end=\"7566\"\u003e Choosing \u003cstrong data-start=\"7535\" data-end=\"7547\"\u003eAirGreen\u003c\/strong\u003e means ensuring: \u003c\/p\u003e\n\n\u003cul data-start=\"7567\" data-end=\"7796\"\u003e\n\n\u003cli data-start=\"7567\" data-end=\"7614\"\u003e\n\n\u003cp data-start=\"7569\" data-end=\"7614\"\u003e From a \u003cstrong data-start=\"7575\" data-end=\"7613\"\u003eteam of experienced refrigeration technicians\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7615\" data-end=\"7674\"\u003e\n\n\u003cp data-start=\"7617\" data-end=\"7674\"\u003e With \u003cstrong data-start=\"7623\" data-end=\"7673\"\u003e$5,000,000 in liability insurance\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7675\" data-end=\"7733\"\u003e\n\n\u003cp data-start=\"7677\" data-end=\"7733\"\u003e \u003cstrong data-start=\"7680\" data-end=\"7701\"\u003eTransparent pricing\u003c\/strong\u003e , communicated before the work begins, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7734\" data-end=\"7796\"\u003e\n\n\u003cp data-start=\"7736\" data-end=\"7796\"\u003e From technical support from the quote to commissioning.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"7798\" data-end=\"7969\"\u003e We don't just install a unit. We design an HVAC solution tailored to your building, your actual usage, and Quebec's climatic conditions.\u003c\/p\u003e\n\n\u003chr data-start=\"7971\" data-end=\"7974\"\u003e\n\n\u003ch2 data-start=\"7976\" data-end=\"8009\"\u003e Conclusion\u003c\/h2\u003e\n\n \u003cp data-start=\"8011\" data-end=\"8415\"\u003eThe \u003cstrong data-start=\"8014\" data-end=\"8089\"\u003eELIOS 24,000 BTU ultra-slim (pancake) heat pump fan coil unit\u003c\/strong\u003e is a suitable solution for projects where discretion, winter performance, and installation flexibility are essential. When properly sized and installed, it perfectly meets the requirements of buildings in \u003cstrong data-start=\"8333\" data-end=\"8345\"\u003eMontreal\u003c\/strong\u003e , \u003cstrong data-start=\"8347\" data-end=\"8356\"\u003eLaval\u003c\/strong\u003e , \u003cstrong data-start=\"8358\" data-end=\"8371\"\u003eLongueuil\u003c\/strong\u003e , the \u003cstrong data-start=\"8379\" data-end=\"8392\"\u003eNorth Shore\u003c\/strong\u003e , and the \u003cstrong data-start=\"8402\" data-end=\"8414\"\u003eSouth Shore\u003c\/strong\u003e .\u003c\/p\u003e\n\n \u003cp data-start=\"8417\" data-end=\"8727\"\u003eFor a \u003cstrong data-start=\"8434\" data-end=\"8458\"\u003edetailed quote\u003c\/strong\u003e , a \u003cstrong data-start=\"8464\" data-end=\"8489\"\u003epersonalized analysis\u003c\/strong\u003e , or \u003cstrong data-start=\"8497\" data-end=\"8546\"\u003etechnical advice tailored to your situation\u003c\/strong\u003e , contact \u003cstrong data-start=\"8577\" data-end=\"8629\"\u003eAirGreen Heat Pumps, Air Conditioning \u0026amp; Heating\u003c\/strong\u003e directly. Our team will support you rigorously and transparently at every stage of your HVAC project.\u003c\/p\u003e","brand":"ELIOS","offers":[{"title":"Default Title","offer_id":51954112233764,"sku":"GPHLA24R4AS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/Extra-flatfancoilconvector_Pancake_-ELIOS_61452caf-ef38-4221-866a-d44bc329ef03.png?v=1769969055"},{"product_id":"ventilo-convecteur-extra-plat-de-thermopompe-elios-30-000-btu","title":"ELIOS Extra-Slim (Pancake) Heat Pump Fan Coil Unit | 30,000 BTU","description":"\u003ch2 data-start=\"94\" data-end=\"175\"\u003e An ultra-slim HVAC solution designed for the structural realities of Quebec\u003c\/h2\u003e\n\n\u003cp data-start=\"177\" data-end=\"643\"\u003e At \u003cstrong data-start=\"182\" data-end=\"194\"\u003eAirGreen\u003c\/strong\u003e , we work daily with buildings that were never designed to accommodate modern HVAC systems: century-old Montreal duplexes, converted commercial buildings, condos with exposed concrete ceilings, and condominiums where every inch counts. In these contexts, the \u003cstrong data-start=\"487\" data-end=\"550\"\u003eELIOS 30,000 BTU ultra-slim (pancake) fan coil unit\u003c\/strong\u003e stands out as a technically sound and truly applicable solution.\u003c\/p\u003e\n\n \u003cp data-start=\"645\" data-end=\"1097\"\u003eThis type of equipment isn't designed to impress on paper, but to \u003cstrong data-start=\"713\" data-end=\"756\"\u003esolve very real constraints\u003c\/strong\u003e : integration into confined spaces, maintaining good air distribution, stable heating performance even in extreme cold, and compatibility with current energy and environmental standards. We're talking about an HVAC unit designed for intelligent integration, without compromising on comfort or reliability.\u003c\/p\u003e\n\n\u003chr data-start=\"1099\" data-end=\"1102\"\u003e\n\n\u003ch2 data-start=\"1104\" data-end=\"1171\"\u003e A pancake format that's actually usable, not just theoretical.\u003c\/h2\u003e\n\n \u003cp data-start=\"1173\" data-end=\"1547\"\u003eThe term \u003cem data-start=\"1182\" data-end=\"1194\"\u003e\"extra-flat\"\u003c\/em\u003e is often overused in the HVAC industry. In the case of the \u003cstrong data-start=\"1274\" data-end=\"1296\"\u003eELIOS GPHLA30R4AS1\u003c\/strong\u003e , it's a truly usable pancake-like form factor: \u003cstrong data-start=\"1352\" data-end=\"1444\"\u003e55.24 inches wide, 23.33 inches deep, and only 10.93 inches high\u003c\/strong\u003e . This slim profile is a game-changer in projects where headroom is limited.\u003c\/p\u003e\n\n \u003cp data-start=\"1549\" data-end=\"1949\"\u003eWe installed this model in corridor ceilings in \u003cstrong data-start=\"1612\" data-end=\"1624\"\u003eMontreal\u003c\/strong\u003e , in commercial spaces in \u003cstrong data-start=\"1647\" data-end=\"1656\"\u003eLaval\u003c\/strong\u003e , and in multi-unit residential buildings on the \u003cstrong data-start=\"1710\" data-end=\"1722\"\u003eSouth Shore\u003c\/strong\u003e , where even the slightest ceiling drop was rejected by the client or architect. In several cases, this fan coil unit made it possible to avoid costly structural work, while maintaining a clean and discreet aesthetic.\u003c\/p\u003e\n\n\u003cp data-start=\"1951\" data-end=\"2266\"\u003e The positioning of the air inlets and outlets, the dedicated suspension brackets, and the overall design facilitate a precise installation, without improvisation. For us, this is essential: a well-designed system must be installed cleanly, without temporary solutions becoming permanent.\u003c\/p\u003e\n\n\u003chr data-start=\"2268\" data-end=\"2271\"\u003e\n\n\u003ch2 data-start=\"2273\" data-end=\"2347\"\u003e 30,000 BTU: a capacity suitable for large areas, without unnecessary excess\u003c\/h2\u003e\n\n \u003cp data-start=\"2349\" data-end=\"2722\"\u003eWith a \u003cstrong data-start=\"2358\" data-end=\"2410\"\u003erated cooling capacity of 30,000 BTU\u003c\/strong\u003e , this fan coil unit is designed for large areas: large condos, office floors, entire retail spaces, or open areas in multi-residential buildings. It's not a unit for a small room, but rather for an area requiring stable and even air distribution.\u003c\/p\u003e\n\n\u003cp data-start=\"2724\" data-end=\"2882\"\u003e Thanks to \u003cstrong data-start=\"2747\" data-end=\"2759\"\u003einverter\u003c\/strong\u003e technology, power is not delivered abruptly. The system continuously modulates according to actual demand, which allows: \u003c\/p\u003e\n\n\u003cul data-start=\"2883\" data-end=\"3056\"\u003e\n\n\u003cli data-start=\"2883\" data-end=\"2913\"\u003e\n\n\u003cp data-start=\"2885\" data-end=\"2913\"\u003e a more stable temperature \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2914\" data-end=\"2965\"\u003e\n\n\u003cp data-start=\"2916\" data-end=\"2965\"\u003e fewer variations felt by the occupants, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2966\" data-end=\"3018\"\u003e\n\n\u003cp data-start=\"2968\" data-end=\"3018\"\u003e improved energy efficiency over time, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3019\" data-end=\"3056\"\u003e\n\n\u003cp data-start=\"3021\" data-end=\"3056\"\u003e a reduction in mechanical wear.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"3058\" data-end=\"3149\"\u003e In terms of heating, the performance is particularly relevant to Quebec's climate: \u003c\/p\u003e\n\n\u003cul data-start=\"3150\" data-end=\"3246\"\u003e\n\n\u003cli data-start=\"3150\" data-end=\"3175\"\u003e\n\n\u003cp data-start=\"3152\" data-end=\"3175\"\u003e \u003cstrong data-start=\"3152\" data-end=\"3174\"\u003e19,000 BTU at -8°C\u003c\/strong\u003e ,\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3176\" data-end=\"3202\"\u003e\n\n \u003cp data-start=\"3178\" data-end=\"3202\"\u003e\u003cstrong data-start=\"3178\" data-end=\"3201\"\u003e19,000 BTU at -15°C\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3203\" data-end=\"3246\"\u003e\n\n\u003cp data-start=\"3205\" data-end=\"3246\"\u003e guaranteed operation down to \u003cstrong data-start=\"3235\" data-end=\"3245\"\u003e-25 °C\u003c\/strong\u003e .\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"3248\" data-end=\"3478\"\u003e In several projects carried out on the \u003cstrong data-start=\"3287\" data-end=\"3300\"\u003eNorth Shore\u003c\/strong\u003e , this level of performance has made it possible to considerably reduce the use of auxiliary heating, even in buildings exposed to wind or with large glazed areas.\u003c\/p\u003e\n\n\u003chr data-start=\"3480\" data-end=\"3483\"\u003e\n\n\u003ch2 data-start=\"3485\" data-end=\"3548\"\u003e Energy efficiency and long-term operating logic\u003c\/h2\u003e\n\n\u003cp data-start=\"3550\" data-end=\"3665\"\u003e The system's efficiency values ​​demonstrate a balanced design, geared towards realistic operation: \u003c\/p\u003e\n\n\u003cul data-start=\"3666\" data-end=\"3752\"\u003e\n\n\u003cli data-start=\"3666\" data-end=\"3684\"\u003e\n\n\u003cp data-start=\"3668\" data-end=\"3684\"\u003e \u003cstrong data-start=\"3668\" data-end=\"3684\"\u003eSEER2: 16.6\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3685\" data-end=\"3702\"\u003e\n\n\u003cp data-start=\"3687\" data-end=\"3702\"\u003e \u003cstrong data-start=\"3687\" data-end=\"3702\"\u003eEER2: 10.5\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3703\" data-end=\"3727\"\u003e\n\n\u003cp data-start=\"3705\" data-end=\"3727\"\u003e \u003cstrong data-start=\"3705\" data-end=\"3727\"\u003eCOP at -8 °C: 2.48\u003c\/strong\u003e \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3728\" data-end=\"3752\"\u003e\n\n\u003cp data-start=\"3730\" data-end=\"3752\"\u003e \u003cstrong data-start=\"3730\" data-end=\"3752\"\u003eCOP at -15 °C: 1.9\u003c\/strong\u003e\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"3754\" data-end=\"4135\"\u003eIn practical terms, this means controlled energy consumption, which is particularly valuable in multi-unit residential buildings and commercial properties where energy costs directly impact profitability. Even though this model does not currently benefit from any provincial subsidies, it remains a relevant option when mechanical constraints make other systems unsuitable.\u003c\/p\u003e\n\n\u003cp data-start=\"4137\" data-end=\"4368\"\u003e At AirGreen, we prefer to be transparent from the outset: this type of device is chosen for its \u003cstrong data-start=\"4239\" data-end=\"4285\"\u003estructural compatibility and reliability\u003c\/strong\u003e , not to maximize a subsidy at the expense of the proper functioning of the building.\u003c\/p\u003e\n\n\u003chr data-start=\"4370\" data-end=\"4373\"\u003e\n\n\u003ch2 data-start=\"4375\" data-end=\"4426\"\u003e Acoustic comfort and indoor air quality\u003c\/h2\u003e\n\n \u003cp data-start=\"4428\" data-end=\"4614\"\u003eComfort is not limited to temperature. \u003cstrong data-start=\"4477\" data-end=\"4492\"\u003eAirflow\u003c\/strong\u003e , \u003cstrong data-start=\"4497\" data-end=\"4514\"\u003enoise level\u003c\/strong\u003e , and \u003cstrong data-start=\"4521\" data-end=\"4542\"\u003edehumidification\u003c\/strong\u003e play a crucial role in the daily experience of occupants.\u003c\/p\u003e\n\n\u003cp data-start=\"4616\" data-end=\"4924\"\u003e The ELIOS fan coil unit offers an airflow of up to \u003cstrong data-start=\"4677\" data-end=\"4688\"\u003e989 CFM\u003c\/strong\u003e , while maintaining a noise level as low as \u003cstrong data-start=\"4740\" data-end=\"4752\"\u003e50 dB(A)\u003c\/strong\u003e at low speed. In offices in \u003cstrong data-start=\"4790\" data-end=\"4803\"\u003eLongueuil\u003c\/strong\u003e , this criterion proved decisive: the system operates continuously without disrupting meetings or focused work.\u003c\/p\u003e\n\n \u003cp data-start=\"4926\" data-end=\"5231\"\u003eThe \u003cstrong data-start=\"4941\" data-end=\"4975\"\u003edehumidification capacity of 5.62 pt\/h\u003c\/strong\u003e is also a significant advantage during the humid summers of \u003cstrong data-start=\"5039\" data-end=\"5051\"\u003eMontreal\u003c\/strong\u003e , the \u003cstrong data-start=\"5059\" data-end=\"5071\"\u003eSouth Shore\u003c\/strong\u003e , and the \u003cstrong data-start=\"5081\" data-end=\"5094\"\u003eNorth Shore\u003c\/strong\u003e . Better humidity control improves comfort, reduces the feeling of heat, and protects interior materials in the long term.\u003c\/p\u003e\n\n\u003chr data-start=\"5233\" data-end=\"5236\"\u003e\n\n\u003ch2 data-start=\"5238\" data-end=\"5287\"\u003e R-454B refrigerant and regulatory compliance\u003c\/h2\u003e\n\n\u003cp data-start=\"5289\" data-end=\"5534\"\u003e The choice of \u003cstrong data-start=\"5301\" data-end=\"5311\"\u003eR-454B\u003c\/strong\u003e is in line with the current regulatory evolution of the HVAC sector. This refrigerant, with its lower global warming potential, represents a realistic transition towards more environmentally friendly solutions.\u003c\/p\u003e\n\n \u003cp data-start=\"5536\" data-end=\"5871\"\u003eIn our daily practice, we observe that buildings equipped with systems compatible with the new standards avoid future constraints: parts availability, regulatory compliance, and ease of maintenance. This is an aspect often overlooked during the purchase phase, but crucial over a 10- to 15-year timeframe.\u003c\/p\u003e\n\n\u003chr data-start=\"5873\" data-end=\"5876\"\u003e\n\n\u003ch2 data-start=\"5878\" data-end=\"5934\"\u003e Installation: the importance of upstream design\u003c\/h2\u003e\n\n\u003cp data-start=\"5936\" data-end=\"6130\"\u003e Installing a \u003cstrong data-start=\"5979\" data-end=\"5993\"\u003e30,000 BTU\u003c\/strong\u003e pancake fan coil unit isn't as simple as hanging it from a ceiling. The most common mistakes we correct during rework include: \u003c\/p\u003e\n\n\u003cul data-start=\"6131\" data-end=\"6347\"\u003e\n\n\u003cli data-start=\"6131\" data-end=\"6170\"\u003e\n\n\u003cp data-start=\"6133\" data-end=\"6170\"\u003e poorly sized conduit networks, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6171\" data-end=\"6204\"\u003e\n\n\u003cp data-start=\"6173\" data-end=\"6204\"\u003e Insufficient static pressure \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6205\" data-end=\"6241\"\u003e\n\n\u003cp data-start=\"6207\" data-end=\"6241\"\u003e No access for maintenance. \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6242\" data-end=\"6288\"\u003e\n\n\u003cp data-start=\"6244\" data-end=\"6288\"\u003e improvised drainage in closed ceilings, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6289\" data-end=\"6347\"\u003e\n\n\u003cp data-start=\"6291\" data-end=\"6347\"\u003e absence of a control strategy adapted to actual use.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"6349\" data-end=\"6639\"\u003eThe \u003cstrong data-start=\"6352\" data-end=\"6361\"\u003eELIOS\u003c\/strong\u003e offers an \u003cstrong data-start=\"6372\" data-end=\"6428\"\u003einternal static pressure of up to 0.8 inWG\u003c\/strong\u003e , allowing for more complex ductwork without sacrificing airflow. This is a major advantage in renovations, where existing configurations often necessitate compromises.\u003c\/p\u003e\n\n\u003cp data-start=\"6641\" data-end=\"6883\"\u003e At AirGreen, every installation begins with a comprehensive analysis: thermal load, air circulation, architectural constraints, and the client's actual expectations. This approach guarantees a high-performing system over the long term.\u003c\/p\u003e\n\n\u003chr data-start=\"6885\" data-end=\"6888\"\u003e\n\n\u003ch2 data-start=\"6890\" data-end=\"6939\"\u003e Options and accessories according to actual needs\u003c\/h2\u003e\n\n\u003cp data-start=\"6941\" data-end=\"7018\"\u003e The ELIOS fan coil unit can be configured with various accessories: \u003c\/p\u003e\n\n\u003cul data-start=\"7019\" data-end=\"7175\"\u003e\n\n\u003cli data-start=\"7019\" data-end=\"7044\"\u003e\n\n\u003cp data-start=\"7021\" data-end=\"7044\"\u003e smart thermostat \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7045\" data-end=\"7066\"\u003e\n\n\u003cp data-start=\"7047\" data-end=\"7066\"\u003e wired controller \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7067\" data-end=\"7128\"\u003e\n\n\u003cp data-start=\"7069\" data-end=\"7128\"\u003e electric heating elements of \u003cstrong data-start=\"7104\" data-end=\"7127\"\u003e5 kW, 8 kW or 10 kW\u003c\/strong\u003e , \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7129\" data-end=\"7175\"\u003e\n\n\u003cp data-start=\"7131\" data-end=\"7175\"\u003e integrated refrigerant detection sensor.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"7177\" data-end=\"7449\"\u003eWe never recommend these options automatically. Each addition is evaluated based on the building type, occupancy, energy strategy, and client objectives. A good HVAC system is a cohesive system, not an accumulation of unnecessary components.\u003c\/p\u003e\n\n\u003chr data-start=\"7451\" data-end=\"7454\"\u003e\n\n\u003ch2 data-start=\"7456\" data-end=\"7504\"\u003e Why entrust this type of project to AirGreen?\u003c\/h2\u003e\n\n\u003cp data-start=\"7506\" data-end=\"7579\"\u003e HVAC installations in confined spaces require real expertise: \u003c\/p\u003e\n\n\u003cul data-start=\"7580\" data-end=\"7809\"\u003e\n\n\u003cli data-start=\"7580\" data-end=\"7633\"\u003e\n\n\u003cp data-start=\"7582\" data-end=\"7633\"\u003e understanding of mechanical and electrical standards, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7634\" data-end=\"7706\"\u003e\n\n\u003cp data-start=\"7636\" data-end=\"7706\"\u003e coordination with architects, electricians and general contractors, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7707\" data-end=\"7752\"\u003e\n\n\u003cp data-start=\"7709\" data-end=\"7752\"\u003e anticipating future maintenance needs, \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7753\" data-end=\"7809\"\u003e\n\n\u003cp data-start=\"7755\" data-end=\"7809\"\u003e Clear documentation and clearly defined technical decisions.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"7811\" data-end=\"8050\"\u003eThis is the rigor we apply to our projects in \u003cstrong data-start=\"7870\" data-end=\"7882\"\u003eMontreal\u003c\/strong\u003e , \u003cstrong data-start=\"7884\" data-end=\"7893\"\u003eLaval\u003c\/strong\u003e , \u003cstrong data-start=\"7895\" data-end=\"7908\"\u003eLongueuil\u003c\/strong\u003e , on the \u003cstrong data-start=\"7917\" data-end=\"7930\"\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong data-start=\"7937\" data-end=\"7949\"\u003eSouth Shore\u003c\/strong\u003e . We don't sell equipment: we design systems adapted to the realities of the building.\u003c\/p\u003e\n\n\u003chr data-start=\"8052\" data-end=\"8055\"\u003e\n\n\u003ch2 data-start=\"8057\" data-end=\"8107\"\u003e A strategic choice for demanding projects\u003c\/h2\u003e\n\n\u003cp data-start=\"8109\" data-end=\"8467\"\u003e The \u003cstrong data-start=\"8112\" data-end=\"8162\"\u003eELIOS 30,000 BTU ultra-slim fan coil unit\u003c\/strong\u003e is not a one-size-fits-all solution. It is designed for projects where space is limited, where consistent performance is essential, and where architectural integration is a priority. When properly sized and installed, it becomes a central component of a reliable, discreet, and long-lasting HVAC system.\u003c\/p\u003e","brand":"ELIOS","offers":[{"title":"Default Title","offer_id":51954112266532,"sku":"GPHLA30R4AS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/Extra-flatfancoilconvector_Pancake_-ELIOS_d0ba5534-37ff-4b81-a230-bb526ac8da7e.png?v=1769969047"},{"product_id":"ventilo-convecteur-extra-plat-de-thermopompe-elios-36-000-btu","title":"ELIOS Extra-Slim (Pancake) Heat Pump Fan Coil Unit | 36,000 BTU","description":"\u003ch2 data-start=\"94\" data-end=\"174\"\u003e An HVAC solution designed for projects where every inch truly counts\u003c\/h2\u003e\n\n\u003cp data-start=\"175\" data-end=\"606\"\u003e In our daily work with \u003cstrong data-start=\"210\" data-end=\"218\"\u003eHVAC professionals\u003c\/strong\u003e in \u003cstrong data-start=\"221\" data-end=\"233\"\u003eMontreal\u003c\/strong\u003e , \u003cstrong data-start=\"235\" data-end=\"244\"\u003eLaval\u003c\/strong\u003e , \u003cstrong data-start=\"246\" data-end=\"259\"\u003eLongueuil\u003c\/strong\u003e , and on the \u003cstrong data-start=\"268\" data-end=\"281\"\u003eNorth\u003c\/strong\u003e and \u003cstrong data-start=\"288\" data-end=\"300\"\u003eSouth\u003c\/strong\u003e Shores, we observe that most constraints stem not from power requirements, but rather from the physical limitations of the building. Low ceilings, exposed beams, concrete structures, renovations with limited flexibility, and conversions of older buildings have become the norm rather than the exception.\u003c\/p\u003e\n\n \u003cp data-start=\"608\" data-end=\"1117\"\u003eIt is precisely in this context that the \u003cstrong data-start=\"650\" data-end=\"725\"\u003eELIOS 36,000 BTU ultra-slim (pancake) fan coil unit for heat pumps\u003c\/strong\u003e truly comes into its own. At AirGreen, we haven't included this model in our product range for theoretical or marketing reasons, but because it directly addresses real-world situations encountered in the field. It delivers \u003cstrong data-start=\"966\" data-end=\"995\"\u003ehigh heating capacity\u003c\/strong\u003e while respecting space constraints that would make many traditional HVAC installations impossible.\u003c\/p\u003e\n\n\u003chr data-start=\"1119\" data-end=\"1122\"\u003e\n\n\u003ch2 data-start=\"1124\" data-end=\"1194\"\u003e A pancake format designed for integration, not compromise\u003c\/h2\u003e\n\n \u003cp data-start=\"1195\" data-end=\"1440\"\u003eThe main advantage of this fan coil unit lies in its \u003cstrong data-start=\"1258\" data-end=\"1279\"\u003eultra-slim profile\u003c\/strong\u003e , designed to fit into tight spaces without sacrificing performance. At approximately \u003cstrong data-start=\"1389\" data-end=\"1402\"\u003e11 inches\u003c\/strong\u003e high, it can be installed: \u003c\/p\u003e\n\n\u003cul data-start=\"1442\" data-end=\"1763\"\u003e\n\n\u003cli data-start=\"1442\" data-end=\"1516\"\u003e\n\n\u003cp data-start=\"1444\" data-end=\"1516\"\u003e in existing basement ceilings, without having to demolish everything; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1517\" data-end=\"1582\"\u003e\n\n\u003cp data-start=\"1519\" data-end=\"1582\"\u003e above narrow corridors in apartment buildings; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1583\" data-end=\"1663\"\u003e\n\n\u003cp data-start=\"1585\" data-end=\"1663\"\u003e in shops where the interior aesthetics do not allow for any visible unity; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"1664\" data-end=\"1763\"\u003e\n\n\u003cp data-start=\"1666\" data-end=\"1763\"\u003e in renovation projects where each structural intervention rapidly increases costs.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"1765\" data-end=\"2152\"\u003eAt AirGreen, we've installed this model in single-family homes in \u003cstrong data-start=\"1843\" data-end=\"1852\"\u003eLaval\u003c\/strong\u003e , duplexes in \u003cstrong data-start=\"1865\" data-end=\"1877\"\u003eMontreal\u003c\/strong\u003e , professional offices in \u003cstrong data-start=\"1908\" data-end=\"1921\"\u003eLongueuil\u003c\/strong\u003e , and even in commercial buildings on the \u003cstrong data-start=\"1968\" data-end=\"1981\"\u003eNorth Shore\u003c\/strong\u003e where technical space was almost nonexistent. In all these cases, the pancake format provided a \u003cstrong data-start=\"2080\" data-end=\"2120\"\u003eclean, discreet, and durable solution\u003c\/strong\u003e , without compromising on comfort.\u003c\/p\u003e\n\n\u003chr data-start=\"2154\" data-end=\"2157\"\u003e\n\n\u003ch2 data-start=\"2159\" data-end=\"2218\"\u003e Airflow and diffusion: an intelligent design\u003c\/h2\u003e\n\n \u003cp data-start=\"2219\" data-end=\"2510\"\u003eA slim unit is only valuable if it can distribute air effectively. The ELIOS 36,000 BTU was designed to maintain a \u003cstrong data-start=\"2348\" data-end=\"2369\"\u003ehigh airflow\u003c\/strong\u003e , capable of efficiently serving open areas, entire homes, or commercial spaces. In practice, this translates to: \u003c\/p\u003e\n\n\u003cul data-start=\"2512\" data-end=\"2715\"\u003e\n\n\u003cli data-start=\"2512\" data-end=\"2574\"\u003e\n\n\u003cp data-start=\"2514\" data-end=\"2574\"\u003e homogeneous diffusion, without cold or overheated areas; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2575\" data-end=\"2639\"\u003e\n\n\u003cp data-start=\"2577\" data-end=\"2639\"\u003e better temperature stability from one room to another; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"2640\" data-end=\"2715\"\u003e\n\n\u003cp data-start=\"2642\" data-end=\"2715\"\u003e a reduction in short cycles, which improves the longevity of the system.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"2717\" data-end=\"3013\"\u003e During our installations, we pay particular attention to duct design, air balancing, and grille placement. It is often this step, neglected elsewhere, that makes the difference between a system that performs well on paper and providing real-world comfort.\u003c\/p\u003e\n\n\u003chr data-start=\"3015\" data-end=\"3018\"\u003e\n\n\u003ch2 data-start=\"3020\" data-end=\"3087\"\u003e Heating performance: a non-negotiable criterion in Quebec\u003c\/h2\u003e\n\n \u003cp data-start=\"3088\" data-end=\"3326\"\u003eIn Quebec, a heating and cooling system must first and foremost be reliable. The \u003cstrong data-start=\"3160\" data-end=\"3188\"\u003eELIOS pancake 36,000 BTU\u003c\/strong\u003e is designed to operate efficiently down to \u003cstrong data-start=\"3237\" data-end=\"3247\"\u003e-25°C\u003c\/strong\u003e , which corresponds to the winter conditions in the greater metropolitan area.\u003c\/p\u003e\n\n\u003cp data-start=\"3328\" data-end=\"3532\"\u003e In practical terms, this means that the system retains a useful heating capacity even when temperatures drop sharply. In our residential and multi-unit projects, this translates to: \u003c\/p\u003e\n\n\u003cul data-start=\"3534\" data-end=\"3699\"\u003e\n\n\u003cli data-start=\"3534\" data-end=\"3577\"\u003e\n\n\u003cp data-start=\"3536\" data-end=\"3577\"\u003e less reliance on backup systems; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3578\" data-end=\"3620\"\u003e\n\n\u003cp data-start=\"3580\" data-end=\"3620\"\u003e a more stable indoor temperature; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"3621\" data-end=\"3699\"\u003e\n\n\u003cp data-start=\"3623\" data-end=\"3699\"\u003e peace of mind for the occupants, even during cold spells.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"3701\" data-end=\"3896\"\u003e For AirGreen, this point is fundamental. We refuse to install equipment that performs well only on paper, but becomes inadequate as soon as the winter becomes more severe.\u003c\/p\u003e\n\n\u003chr data-start=\"3898\" data-end=\"3901\"\u003e\n\n\u003ch2 data-start=\"3903\" data-end=\"3955\"\u003e Summer air conditioning and humidity management\u003c\/h2\u003e\n\n \u003cp data-start=\"3956\" data-end=\"4201\"\u003eDuring the summer months, comfort depends not only on temperature but also on humidity control. The ELIOS 36,000 BTU fan coil unit offers \u003cstrong data-start=\"4119\" data-end=\"4166\"\u003esignificant dehumidification capacity\u003c\/strong\u003e , particularly appreciated in: \u003c\/p\u003e\n\n\u003cul data-start=\"4203\" data-end=\"4337\"\u003e\n\n\u003cli data-start=\"4203\" data-end=\"4229\"\u003e\n\n\u003cp data-start=\"4205\" data-end=\"4229\"\u003e the converted basements; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4230\" data-end=\"4267\"\u003e\n\n\u003cp data-start=\"4232\" data-end=\"4267\"\u003e old apartment buildings; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4268\" data-end=\"4337\"\u003e\n\n\u003cp data-start=\"4270\" data-end=\"4337\"\u003e commercial spaces exposed to varying humidity levels.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"4339\" data-end=\"4652\"\u003e At AirGreen, we've observed that many customers attribute summer discomfort to insufficient power, when it's often actually a problem of poorly managed humidity. This model allows you to directly address this factor, improving comfort without unnecessarily oversizing the system.\u003c\/p\u003e\n\n\u003chr data-start=\"4654\" data-end=\"4657\"\u003e\n\n\u003ch2 data-start=\"4659\" data-end=\"4720\"\u003e Energy efficiency and controlled operating costs\u003c\/h2\u003e\n\n \u003cp data-start=\"4721\" data-end=\"4883\"\u003eThe ELIOS pancake 36,000 BTU also stands out for its \u003cstrong data-start=\"4780\" data-end=\"4809\"\u003eenergy efficiency\u003c\/strong\u003e , both in cooling and heating. This efficiency translates into: \u003c\/p\u003e\n\n\u003cul data-start=\"4885\" data-end=\"5031\"\u003e\n\n\u003cli data-start=\"4885\" data-end=\"4932\"\u003e\n\n\u003cp data-start=\"4887\" data-end=\"4932\"\u003e better controlled electricity consumption; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4933\" data-end=\"4966\"\u003e\n\n\u003cp data-start=\"4935\" data-end=\"4966\"\u003e more predictable bills; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"4967\" data-end=\"5031\"\u003e\n\n\u003cp data-start=\"4969\" data-end=\"5031\"\u003e improved compatibility with grant programs.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"5033\" data-end=\"5271\"\u003e In a context where energy costs are playing an increasingly important role in purchasing decisions, this point becomes a decisive argument, both for owner-occupiers and for building managers.\u003c\/p\u003e\n\n\u003chr data-start=\"5273\" data-end=\"5276\"\u003e\n\n\u003ch2 data-start=\"5278\" data-end=\"5333\"\u003e R-454B refrigerant: a future-proof choice\u003c\/h2\u003e\n\n\u003cp data-start=\"5334\" data-end=\"5460\"\u003e The choice of \u003cstrong data-start=\"5346\" data-end=\"5356\"\u003eR-454B\u003c\/strong\u003e meets current and future environmental requirements. For AirGreen customers, this means: \u003c\/p\u003e\n\n\u003cul data-start=\"5462\" data-end=\"5600\"\u003e\n\n\u003cli data-start=\"5462\" data-end=\"5507\"\u003e\n\n\u003cp data-start=\"5464\" data-end=\"5507\"\u003e a system that complies with emerging standards; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5508\" data-end=\"5553\"\u003e\n\n\u003cp data-start=\"5510\" data-end=\"5553\"\u003e a reduction in environmental impact; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"5554\" data-end=\"5600\"\u003e\n\n\u003cp data-start=\"5556\" data-end=\"5600\"\u003e improved long-term viability of the investment.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n \u003cp data-start=\"5602\" data-end=\"5797\"\u003eIn several commercial and multi-residential projects, this criterion is now essential, particularly when it comes to regulatory compliance and the long-term value of the building.\u003c\/p\u003e\n\n\u003chr data-start=\"5799\" data-end=\"5802\"\u003e\n\n\u003ch2 data-start=\"5804\" data-end=\"5859\"\u003e Acoustic comfort: an often underestimated aspect\u003c\/h2\u003e\n\n\u003cp data-start=\"5860\" data-end=\"6064\"\u003e Noise level is a key factor in the acceptance of an HVAC system. The ELIOS pancake was designed to offer \u003cstrong data-start=\"5978\" data-end=\"6017\"\u003erelatively quiet operation\u003c\/strong\u003e , even at high airflow rates. This allows: \u003c\/p\u003e\n\n\u003cul data-start=\"6066\" data-end=\"6232\"\u003e\n\n\u003cli data-start=\"6066\" data-end=\"6124\"\u003e\n\n\u003cp data-start=\"6068\" data-end=\"6124\"\u003e an installation in offices without noise pollution; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6125\" data-end=\"6175\"\u003e\n\n\u003cp data-start=\"6127\" data-end=\"6175\"\u003e comfortable residential use, even at night; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6176\" data-end=\"6232\"\u003e\n\n\u003cp data-start=\"6178\" data-end=\"6232\"\u003e improved long-term occupant satisfaction.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"6234\" data-end=\"6423\"\u003e At AirGreen, we always include this aspect in our recommendations, because a system that is too noisy quickly becomes a source of dissatisfaction, regardless of its thermal performance.\u003c\/p\u003e\n\n\u003chr data-start=\"6425\" data-end=\"6428\"\u003e\n\n\u003ch2 data-start=\"6430\" data-end=\"6498\"\u003e Installation: AirGreen's expertise as a real added value\u003c\/h2\u003e\n\n \u003cp data-start=\"6499\" data-end=\"6753\"\u003eInstalling an ultra-slim fan coil unit requires more than just compliance with basic standards. The management of suspension, piping, drainage, power supply, and accessibility for maintenance must be considered from the outset.\u003c\/p\u003e\n\n\u003cp data-start=\"6755\" data-end=\"6796\"\u003e Our approach at AirGreen is based on: \u003c\/p\u003e\n\n\u003cul data-start=\"6797\" data-end=\"6971\"\u003e\n\n\u003cli data-start=\"6797\" data-end=\"6848\"\u003e\n\n\u003cp data-start=\"6799\" data-end=\"6848\"\u003e a detailed analysis of the existing structure; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6849\" data-end=\"6895\"\u003e\n\n\u003cp data-start=\"6851\" data-end=\"6895\"\u003e precise location planning; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"6896\" data-end=\"6971\"\u003e\n\n\u003cp data-start=\"6898\" data-end=\"6971\"\u003e a careful installation aimed at durability and ease of maintenance.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"6973\" data-end=\"7115\"\u003e This rigor helps to avoid common problems such as vibrations, unwanted noise, or poorly managed condensation flows.\u003c\/p\u003e\n\n\u003chr data-start=\"7117\" data-end=\"7120\"\u003e\n\n\u003ch2 data-start=\"7122\" data-end=\"7164\"\u003e Feedback from the field and concrete scenarios\u003c\/h2\u003e\n\n \u003cp data-start=\"7165\" data-end=\"7469\"\u003eIn a \u003cstrong data-start=\"7197\" data-end=\"7209\"\u003eMontreal\u003c\/strong\u003e residential building, the owner was hesitant to upgrade their HVAC system due to low ceilings and the impossibility of installing a standard unit. The choice of the \u003cstrong data-start=\"7361\" data-end=\"7408\"\u003eELIOS 36,000 BTU pancake fan coil unit\u003c\/strong\u003e , combined with a customized installation by AirGreen, made it possible to: \u003c\/p\u003e\n\n\u003cul data-start=\"7471\" data-end=\"7635\"\u003e\n\n\u003cli data-start=\"7471\" data-end=\"7534\"\u003e\n\n\u003cp data-start=\"7473\" data-end=\"7534\"\u003e a complete modernization without major structural work; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7535\" data-end=\"7590\"\u003e\n\n\u003cp data-start=\"7537\" data-end=\"7590\"\u003e a noticeable improvement in comfort in both winter and summer; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"7591\" data-end=\"7635\"\u003e\n\n\u003cp data-start=\"7593\" data-end=\"7635\"\u003e long-term building appreciation.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"7637\" data-end=\"7728\"\u003e This type of situation is far from isolated and perfectly illustrates the value of this model.\u003c\/p\u003e\n\n\u003chr data-start=\"7730\" data-end=\"7733\"\u003e\n\n\u003ch2 data-start=\"7735\" data-end=\"7768\"\u003e Warranty, maintenance and follow-up\u003c\/h2\u003e\n\n\u003cp data-start=\"7769\" data-end=\"8013\"\u003e The system comes with a warranty covering the compressor and parts, with additional options available depending on the project. At AirGreen, we also emphasize the importance of \u003cstrong data-start=\"7968\" data-end=\"7995\"\u003eregular HVAC maintenance\u003c\/strong\u003e , which is essential for: \u003c\/p\u003e\n\n\u003cul data-start=\"8015\" data-end=\"8134\"\u003e\n\n\u003cli data-start=\"8015\" data-end=\"8055\"\u003e\n\n \u003cp data-start=\"8017\" data-end=\"8055\"\u003emaintain energy performance; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"8056\" data-end=\"8101\"\u003e\n\n\u003cp data-start=\"8058\" data-end=\"8101\"\u003e extend the lifespan of the equipment; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"8102\" data-end=\"8134\"\u003e\n\n\u003cp data-start=\"8104\" data-end=\"8134\"\u003e prevent costly breakdowns.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp data-start=\"8136\" data-end=\"8243\"\u003e Our after-sales service is an integral part of our approach, going far beyond simple installation.\u003c\/p\u003e\n\n\u003chr data-start=\"8245\" data-end=\"8248\"\u003e\n\n\u003ch2 data-start=\"8250\" data-end=\"8317\"\u003e Why AirGreen is the right partner for this type of project\u003c\/h2\u003e\n\n\u003cp data-start=\"8318\" data-end=\"8503\"\u003e The \u003cstrong data-start=\"8321\" data-end=\"8371\"\u003eELIOS 36,000 BTU ultra-slim fan coil unit\u003c\/strong\u003e is an excellent piece of equipment, but its full potential is only realized with proper installation. AirGreen stands out because: \u003c\/p\u003e\n\n\u003cul data-start=\"8505\" data-end=\"8759\"\u003e\n\n\u003cli data-start=\"8505\" data-end=\"8559\"\u003e\n\n\u003cp data-start=\"8507\" data-end=\"8559\"\u003e concrete experience in complex projects; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"8560\" data-end=\"8673\"\u003e\n\n\u003cp data-start=\"8562\" data-end=\"8673\"\u003e an in-depth knowledge of the built environment of \u003cstrong data-start=\"8602\" data-end=\"8614\"\u003eMontreal\u003c\/strong\u003e , \u003cstrong data-start=\"8616\" data-end=\"8625\"\u003eLaval\u003c\/strong\u003e , \u003cstrong data-start=\"8627\" data-end=\"8640\"\u003eLongueuil\u003c\/strong\u003e , \u003cstrong data-start=\"8642\" data-end=\"8655\"\u003eNorth Shore\u003c\/strong\u003e and \u003cstrong data-start=\"8659\" data-end=\"8671\"\u003eSouth Shore\u003c\/strong\u003e ; \u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\u003cli data-start=\"8674\" data-end=\"8759\"\u003e\n\n\u003cp data-start=\"8676\" data-end=\"8759\"\u003e a transparent, professional and sustainable solutions-oriented approach.\u003c\/p\u003e\n\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e","brand":"ELIOS","offers":[{"title":"Default Title","offer_id":51954112299300,"sku":"GPHLA36R4AS1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/Extra-flatfancoilconvector_Pancake_-ELIOS_c2b60ca7-9056-4e4e-8b96-0c534a7bc529.png?v=1769969040"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/collections\/Extra-flat_fan_coil_convector_Pancake_-_ELIOS_d8068f4e-7526-4225-b47a-d4e5a5d81e84.png?v=1769967817","url":"https:\/\/airgreen.ca\/en\/collections\/elios-ventilo-convecteur-extra-plat-pancake-thermopompe-montreal-laval-longueuil-rive-sud-rive-nord.oembed","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}