{"title":"ADP Evaporator Coil | Montreal, Laval, Longueuil, South Shore and North Shore","description":null,"products":[{"product_id":"serpentin-devaporateur-adp-he31130c175b1622ap-a-2-5-tonnes","title":"ADP HE31130C175B1622AP Evaporator A-Coil | 2.5 Tons","description":"\u003ch2\u003eA 2.5-ton coil that installs upright or lying down\u003c\/h2\u003e\n\u003ch3\u003eA coil that ships in its cabinet\u003c\/h3\u003e\n\u003cp\u003eADP’s HE31130C175B1622AP is an evaporator A-coil already mounted in an embossed cabinet 16.5 in high, 17.5 in wide and 20.5 in deep. There is no cabinet to build on site: the coil connects directly to the outlet of the electric furnace or air handler, then to the ductwork. Its nominal size is 2.5 tons, or 30,000 BTU\/h, and it forms the indoor part of a central air conditioner or central heat pump, two uses ADP states its HE coils are compatible with.\u003c\/p\u003e\n\u003ch3\u003eUpright or horizontal\u003c\/h3\u003e\n\u003cp\u003eWhat sets this model apart is its multi-position design. ADP designs it for upflow, or for horizontal installation to the left or right. It ships in a left-hand configuration (code 22) and converts on site.\u003c\/p\u003e\n\u003cp\u003eThis helps in several common situations around \u003cstrong\u003eMontreal\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ean air handler lying in a basement ceiling, to keep the room clear;\u003c\/li\u003e\n\u003cli\u003ea unit installed in a crawl space, where the height does not allow a vertical installation;\u003c\/li\u003e\n\u003cli\u003ea townhouse or condo with a narrow mechanical room.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor a downflow unit, ADP’s documentation does not clearly confirm this model: we then validate the configuration with the manufacturer before ordering.\u003c\/p\u003e\n\u003ch3\u003eThe technical details that matter\u003c\/h3\u003e\n\u003cp\u003eMetering is by piston, on R-410A. Because the piston must match the outdoor unit, we check it before commissioning. The E31 slab is copper, the connections are brazed and the suction is 3\/4 in ODF. The drain pan is moulded from UV-resistant, 450°F polymer with Microban antimicrobial additive, and the coil undergoes a helium leak test and a 500 psi air pressure test at the factory. It weighs 38 lb.\u003c\/p\u003e\n\u003cp\u003eA coil sold alone has no efficiency rating of its own; it is not eligible for the LogisVert grant. ADP warrants it for 5 years on parts, with a possible extension to 10 years under the conditions of its extended warranty; labour is not covered by the manufacturer.\u003c\/p\u003e\n\u003ch3\u003eLeave it to AirGreen\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). We assess your installation on site free of charge, choose the coil position, prepare a written quote, then set the coil, braze the connections, connect the drain and commission the system. We serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTell us about your unit and where it sits: the estimate is free, the quote is in writing and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":67801489604900,"sku":"HE31130C175B1622AP","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HE_BOITIER_HE31130C175B1622AP_00_2_5_T_BOITIER_17_5_PO_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082502"},{"product_id":"serpentin-devaporateur-adp-he31130c210b1622ap-a-2-5-tonnes","title":"ADP HE31130C210B1622AP Evaporator A-Coil | 2.5 Tons","description":"\u003ch2\u003eA 21 in ADP coil that lines up with your unit\u003c\/h2\u003e\n\u003ch3\u003eWhy cabinet width matters\u003c\/h3\u003e\n\u003cp\u003eA cased coil sits directly on the air outlet of the electric furnace or air handler. When both are the same width, the connection is simple, clean and easy to seal. When they differ, a transition has to be built. ADP’s HE31130C210B1622AP is therefore aimed first at 21 in wide units: its embossed cabinet is 21.0 in wide, 16.5 in high and 20.5 in deep.\u003c\/p\u003e\n\u003cp\u003eFor the same capacity, the HE series also offers a narrower cabinet. During the visit, we measure your unit and choose the width that fits, rather than adapting the job to the coil.\u003c\/p\u003e\n\u003ch3\u003eThe HE31130C210B1622AP sheet\u003c\/h3\u003e\n\u003cp\u003eIts nominal size is 2.5 tons, or 30,000 BTU\/h. It uses an E31 copper slab and piston metering on R-410A. The copper connections are brazed, with a 3\/4 in ODF suction. The drain pan is UV-resistant, 450°F polymer treated with Microban antimicrobial additive. At the factory, ADP checks for leaks with helium and pressurizes the coil to 500 psi with air. It weighs 38 lb.\u003c\/p\u003e\n\u003cp\u003eADP describes it as multi-position: upflow, or horizontal to the left or right, converted on site from the original left-hand configuration (code 22). Downflow is not clearly confirmed for this model; in that case, we validate with the manufacturer before ordering.\u003c\/p\u003e\n\u003ch3\u003eIn your home\u003c\/h3\u003e\n\u003cp\u003eThe typical case: a split-level or cottage heated by a 21 in electric furnace, whose owners want air conditioning or a 2.5-ton central heat pump. ADP states that HE coils are compatible with both uses. With piston metering, we make sure the orifice suits the chosen outdoor unit. If the unit lies in the basement ceiling, the same coil installs horizontally, on the side required.\u003c\/p\u003e\n\u003cp\u003eSold alone, the coil has no efficiency rating of its own and is not eligible for the LogisVert grant. Its ADP warranty covers parts for 5 years from installation, with a possible extension to 10 years under the manufacturer’s conditions; labour is not included.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen does\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eA free on-site estimate: measuring the unit, choosing the coil and its position.\u003c\/li\u003e\n\u003cli\u003eA clear written quote before work begins.\u003c\/li\u003e\n\u003cli\u003eSetting the coil, brazing the connections, connecting the drain and commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). We serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSend us your unit’s width or book a free visit. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":67801492095268,"sku":"HE31130C210B1622AP","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HE_BOITIER_HE31130C210B1622AP_00_2_5_T_BOITIER_21_PO_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082502"},{"product_id":"serpentin-devaporateur-adp-he32136c175b1622ap-a-3-tonnes","title":"ADP HE32136C175B1622AP Evaporator A-Coil | 3 Tons","description":"\u003ch2\u003eThree tons of cooling in a compact ADP cabinet\u003c\/h2\u003e\n\u003ch3\u003eA coil for narrow mechanical rooms\u003c\/h3\u003e\n\u003cp\u003eIn a townhouse or semi-detached home, the electric furnace often sits in a narrow corner of the basement, between the water heater and a wall. Adding a 3-ton coil in that space calls for a cabinet that stays compact. ADP’s HE32136C175B1622AP fits a coil with a 3-ton (36,000 BTU\/h) nominal size into an embossed cabinet 17.5 in wide, 16.5 in high and 20.5 in deep.\u003c\/p\u003e\n\u003cp\u003eIt connects to an electric furnace or air handler of the same width and becomes the indoor part of a central air conditioner or central heat pump; ADP states its HE coils are compatible with both uses. Its multi-position design also allows horizontal installation, to the left or right, when the unit lies in the ceiling.\u003c\/p\u003e\n\u003ch3\u003eHow we install it\u003c\/h3\u003e\n\u003cp\u003eEverything starts with a free visit. We measure the unit and the mechanical room, check access (the coil weighs 46 lb) and confirm the match with the 3-ton outdoor unit. Because metering is by piston, we check that the orifice suits that unit. If the unit’s width does not match the 17.5 in cabinet, we plan a transition or offer another HE coil. You then receive a written quote.\u003c\/p\u003e\n\u003cp\u003eOn installation day, our technicians set the coil in the chosen position, braze the copper connections, including the 3\/4 in ODF suction, connect the drain pan and commission the system. Before leaving, they check operation in cooling and, with a heat pump, in heating. The coil ships in a left-hand configuration (code 22) and converts on site; for a downflow unit, a configuration not clearly confirmed for this model, we validate with ADP first.\u003c\/p\u003e\n\u003ch3\u003eThe specifications ADP publishes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eE32 copper slab, piston metering on R-410A.\u003c\/li\u003e\n\u003cli\u003eUV-resistant, 450°F polymer drain pan with Microban antimicrobial additive.\u003c\/li\u003e\n\u003cli\u003eHelium leak test and 500 psi air pressure test at the factory.\u003c\/li\u003e\n\u003cli\u003e5-year limited parts warranty, extendable to 10 years under ADP’s conditions; labour is not covered by the manufacturer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA coil sold alone has no efficiency rating of its own and is not eligible for the LogisVert grant: performance depends on the outdoor unit and indoor unit it is matched with.\u003c\/p\u003e\n\u003ch3\u003eAirGreen, close to home\u003c\/h3\u003e\n\u003cp\u003eA family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Our teams work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate: we measure, confirm the match and give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":67801495798052,"sku":"HE32136C175B1622AP","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HE_BOITIER_HE32136C175B1622AP_00_3_T_BOITIER_17_5_PO_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082502"},{"product_id":"serpentin-devaporateur-adp-he33136c210b2022ap-a-3-tonnes","title":"ADP HE33136C210B2022AP Evaporator A-Coil | 3 Tons","description":"\u003ch2\u003eA 3-ton ADP coil built for 21 in units\u003c\/h2\u003e\n\u003ch3\u003eThe typical scenario\u003c\/h3\u003e\n\u003cp\u003eA two-storey cottage, a 21 in wide electric furnace in the basement, ductwork serving every room, and owners who want air conditioning in summer or a 3-ton central heat pump. That is exactly the kind of project ADP’s HE33136C210B2022AP is aimed at. This evaporator A-coil, with a 3-ton (36,000 BTU\/h) nominal size, ships in a 21.0 in wide embossed cabinet that lines up with the unit, without a transition. ADP states its HE coils are compatible with air conditioning and heat pumps.\u003c\/p\u003e\n\u003cp\u003eIn winter, with a heat pump, this same coil transfers heat to the air in the house; the electric furnace stays in place as backup heat. And if the air handler lies in the basement ceiling, the coil installs horizontally, provided the clearance allows it.\u003c\/p\u003e\n\u003ch3\u003eWhat you get\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAn E33 copper slab in a 20.5 x 21.0 x 20.5 in (H x W x D) cabinet, weighing 50 lb.\u003c\/li\u003e\n\u003cli\u003eA multi-position design: upflow, or horizontal to the left or right, field convertible from the original left-hand configuration (code 22).\u003c\/li\u003e\n\u003cli\u003ePiston metering on R-410A and copper connections for brazing, including the 3\/4 in ODF suction.\u003c\/li\u003e\n\u003cli\u003eA UV-resistant, 450°F polymer drain pan with Microban antimicrobial additive.\u003c\/li\u003e\n\u003cli\u003eA coil factory tested with helium and at 500 psi air pressure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePoints to check before installation\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eHeight: with a 20.5 in cabinet, the space under the main duct must be sufficient.\u003c\/li\u003e\n\u003cli\u003eThe unit’s width, which must match the cabinet’s 21.0 in, otherwise a transition is needed.\u003c\/li\u003e\n\u003cli\u003eThe piston, which must suit the chosen 3-ton outdoor unit.\u003c\/li\u003e\n\u003cli\u003eAirflow direction: for a downflow unit, a configuration not clearly confirmed for this model, we validate with ADP before ordering.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eA coil sold alone has no efficiency rating of its own and is not eligible for the LogisVert grant. On warranty, ADP covers parts for 5 years from installation; the extension to 10 years follows the manufacturer’s conditions, and in Quebec not registering does not reduce coverage. Labour is not covered by the manufacturer.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). We carry out these checks during a free on-site estimate, then give you a written quote. Our technicians then set the coil, braze the connections, connect the drain and commission the system, in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIf your project looks like this scenario, ask for your free estimate; \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":67801501106468,"sku":"HE33136C210B2022AP","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HE_BOITIER_HE33136C210B2022AP_00_3_T_BOITIER_21_PO_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082502"},{"product_id":"serpentin-devaporateur-adp-he36160c210b2522ap-a-5-tonnes","title":"ADP HE36160C210B2522AP Evaporator A-Coil | 5 Tons","description":"\u003ch2\u003eA 5-ton ADP coil for large central systems\u003c\/h2\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eADP’s HE36160C210B2522AP is an evaporator A-coil with a 5-ton nominal size, or 60,000 BTU\/h. It is aimed at large single-family homes, enlarged residences and small commercial spaces whose ductwork serves a large area. It connects to a 21 in wide electric furnace or air handler and forms the indoor part of a central air conditioner or central heat pump; ADP states its HE coils are compatible with both uses.\u003c\/p\u003e\n\u003cp\u003eChoosing a 5-ton coil always goes together with the outdoor unit: the two must form a coherent set, and ADP does not name a specific model. We therefore confirm the match before any order.\u003c\/p\u003e\n\u003ch3\u003eWhat the size changes at installation\u003c\/h3\u003e\n\u003cp\u003eA coil of this capacity calls for a few precautions that we build into the quote from the start.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eThe suction line.\u003c\/strong\u003e The connection is 7\/8 in ODF. If the existing refrigerant lines are a different size, we plan for adapting or replacing them.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eThe weight.\u003c\/strong\u003e The coil weighs 64 lb. Lying horizontally, in a basement ceiling for example, it must be firmly supported.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eThe height.\u003c\/strong\u003e The embossed cabinet is 25.5 in high, 21.0 in wide and 20.5 in deep: the space under the main duct must allow for it.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eThe piston.\u003c\/strong\u003e Metering is by piston on R-410A; we check that it suits the chosen 5-ton outdoor unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe model is multi-position: upflow, or horizontal to the left or right, field convertible from the original left-hand configuration (code 22). For a downflow unit, a configuration ADP’s documentation does not clearly confirm for this model, we validate with the manufacturer before ordering.\u003c\/p\u003e\n\u003ch3\u003eConstruction\u003c\/h3\u003e\n\u003cp\u003eADP uses an E36 copper slab with brazed connections, a UV-resistant, 450°F polymer drain pan treated with Microban antimicrobial additive, and puts the coil through a helium leak test and a 500 psi air pressure test. The manufacturer’s limited warranty covers parts for 5 years from installation, extendable to 10 years under its conditions; labour is not part of it.\u003c\/p\u003e\n\u003cp\u003eSold alone, the coil has no efficiency rating of its own and is not eligible for the LogisVert grant.\u003c\/p\u003e\n\u003ch3\u003eA project this size, with AirGreen\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). We assess the installation on site free of charge, give you a written quote, then set and support the coil, braze the connections, connect the drain and commission the system. We serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate for a 5-ton system; \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":67801510281508,"sku":"HE36160C210B2522AP","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HE_BOITIER_HE36160C210B2522AP_00_5_T_BOITIER_21_PO_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082502"},{"product_id":"serpentin-devaporateur-adp-he50160c245b2722ap-a-5-tonnes","title":"ADP HE50160C245B2722AP Evaporator A-Coil | 5 Tons","description":"\u003ch2\u003eThe 5-ton ADP coil for 24.5 in units\u003c\/h2\u003e\n\u003ch3\u003eA wide cabinet that lines up with the unit\u003c\/h3\u003e\n\u003cp\u003eSome high-capacity air handlers and electric furnaces are 24.5 in wide. Pairing them with a narrower coil means building a transition, with the connections and sealing that involves. ADP’s HE50160C245B2722AP avoids that step: its embossed cabinet is 24.5 in wide, 27.5 in high and 20.5 in deep, and lines up with the unit.\u003c\/p\u003e\n\u003cp\u003eWith a 5-ton (60,000 BTU\/h) nominal size, it forms the indoor part of a central air conditioner or central heat pump, two uses ADP states its HE coils are compatible with. It suits large homes as well as small commercial spaces whose ductwork serves a large area.\u003c\/p\u003e\n\u003cp\u003eAt 27.5 in high, the cabinet also needs generous vertical clearance above the unit. In a basement where the main duct runs low, it can be simpler to install the assembly horizontally: we compare both options during the visit and present them in the quote.\u003c\/p\u003e\n\u003ch3\u003eA \"Non-Core\" option: plan for the lead time\u003c\/h3\u003e\n\u003cp\u003eThis model uses the E50 slab, which ADP classifies among its \"Non-Core\" options. According to the manufacturer, core options offer better availability. In practice, we confirm the supply lead time before setting the date of the work, so that your installation is not scheduled around a part that has not yet arrived.\u003c\/p\u003e\n\u003ch3\u003eThe sheet at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eE50 copper slab, piston metering on R-410A.\u003c\/li\u003e\n\u003cli\u003e7\/8 in ODF suction connection, copper, for brazing.\u003c\/li\u003e\n\u003cli\u003eMulti-position design: upflow, or horizontal to the left or right, field convertible from the original left-hand configuration (code 22).\u003c\/li\u003e\n\u003cli\u003eUV-resistant, 450°F polymer drain pan with Microban antimicrobial additive.\u003c\/li\u003e\n\u003cli\u003eHelium leak test and 500 psi air pressure test at the factory.\u003c\/li\u003e\n\u003cli\u003eWeight: 72 lb.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor a downflow unit, ADP’s documentation does not clearly confirm this model: we then validate with the manufacturer. Sold alone, the coil has no efficiency rating of its own and is not eligible for the LogisVert grant. ADP warrants it for 5 years on parts from installation, with a possible extension to 10 years under its conditions; labour is not covered by the manufacturer.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). After a free on-site estimate and a written quote, our technicians set and support the coil, braze the connections, check the piston, connect the drain and commission the system. We serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLet’s measure your unit and confirm the lead time together: the estimate is free and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":67801527091492,"sku":"HE50160C245B2722AP","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HE_BOITIER_HE50160C245B2722AP_00_5_T_BOITIER_24_5_PO_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082502"},{"product_id":"serpentin-devaporateur-adp-he30924a140a0000ap-a-1-5-2-tonnes","title":"ADP HE30924A140A0000AP Evaporator A-Coil | 1.5-2 Tons","description":"\u003ch2\u003eA low-profile coil that adds air conditioning to your central system\u003c\/h2\u003e\n\u003ch3\u003eAn A-coil for 1.5 to 2-ton systems\u003c\/h3\u003e\n\u003cp\u003eADP’s HE30924A140A0000AP is an evaporator A-coil shipped without a cabinet. It sits in the plenum of your electric furnace or air handler and becomes the indoor part of a central air conditioner or central heat pump. Its capacity code 24 corresponds to 24,000 BTU, and ADP’s selection table lists its E30 slab in the 18 and 24 MBTUH rows: it is meant for homes with a 1.5 to 2-ton outdoor unit.\u003c\/p\u003e\n\u003cp\u003eIts 11 in coil height is its main advantage. In a basement with a low ceiling, or above a unit that is already tall, every inch counts, and a taller coil would often mean rebuilding part of the ductwork. It suits bungalows, condos with a central system and small townhouses.\u003c\/p\u003e\n\u003ch3\u003eWhat the manufacturer built in\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ea non-bleed thermostatic expansion valve (TXV), designed for air conditioning and heat pumps on R-410A;\u003c\/li\u003e\n\u003cli\u003ea copper coil with brazed connections, including a 3\/4 in ODF suction connection;\u003c\/li\u003e\n\u003cli\u003ea drain pan moulded from UV-resistant, 450°F polymer, treated with Microban antimicrobial additive;\u003c\/li\u003e\n\u003cli\u003efactory testing: helium leak test and 500 psi air pressure test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eADP publishes a reference airflow of 800 CFM at 24 MBTUH. Like any coil sold alone, it has no efficiency rating of its own: system performance depends on the outdoor unit and indoor unit it works with. For the same reason, it is not eligible for the LogisVert grant when sold alone.\u003c\/p\u003e\n\u003ch3\u003eIn a Quebec home\u003c\/h3\u003e\n\u003cp\u003eThe most common case among our customers: a house heated by an electric furnace that wants to add air conditioning, or install a central heat pump on the existing ductwork. The coil goes above the unit, in the plenum. Because its pan is 14.0 in wide and 19.5 in deep, we first check the plenum and unit dimensions so that everything fits cleanly.\u003c\/p\u003e\n\u003cp\u003eThe model is designed for upflow or downflow installation. If your unit lies horizontally, for example in a crawl space, we will recommend a cased multi-position HE coil instead.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). Our technicians:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eassess your system on site, free of charge, and confirm the match with the outdoor unit;\u003c\/li\u003e\n\u003cli\u003eadapt the plenum and set the coil;\u003c\/li\u003e\n\u003cli\u003ebraze the copper connections and connect the drain pan;\u003c\/li\u003e\n\u003cli\u003ecommission the system and check that it runs properly before leaving.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eYou receive a written quote before work begins. We serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet’s talk about your project\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBook your free in-home estimate: we confirm the match, measure the plenum and give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available on our installation projects.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":67801540362532,"sku":"HE30924A140A0000AP","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HE_SANS_BOITIER_HE30924A140A0000AP_00_1_5_2_T_24_000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082502"},{"product_id":"serpentin-devaporateur-adp-he31930a140a0000ap-a","title":"ADP HE31930A140A0000AP Evaporator A-Coil","description":"\u003ch2\u003eThe ADP TXV coil for moving to a central heat pump\u003c\/h2\u003e\n\u003ch3\u003eA central heat pump without changing the indoor unit\u003c\/h3\u003e\n\u003cp\u003eIn many homes in the region, an electric furnace already moves air through ductwork. Adding a central heat pump does not mean replacing everything: it takes an evaporator coil above the furnace and a matched outdoor unit. The furnace stays in place, blows the air and provides backup heat.\u003c\/p\u003e\n\u003cp\u003eADP’s HE31930A140A0000AP plays that coil role. It is an A-coil shipped without a cabinet, in a right-hand configuration, that sits in the plenum of the electric furnace or an air handler. It suits split-levels, cottages and semi-detached homes that want air conditioning in summer and a heat pump in winter, on the existing ductwork.\u003c\/p\u003e\n\u003ch3\u003eWhat the ADP sheet says\u003c\/h3\u003e\n\u003cp\u003eThe model number reads with the manufacturer’s nomenclature. Under that nomenclature, capacity code 30 stands for 30,000 BTU\/h nominal, and ADP publishes a reference airflow of 1,000 CFM at 30 MBTUH. Its selection table lists the E31 slab in the 18, 24 and 30 MBTUH rows: this is why we always confirm the exact match with the outdoor unit before ordering.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eExpansion valve: non-bleed TXV, designed for heat pump and air conditioning use on R-410A.\u003c\/li\u003e\n\u003cli\u003eCoil: E31 copper slab, 13 in high, with a 3\/4 in ODF suction connection for brazing.\u003c\/li\u003e\n\u003cli\u003eDrain pan: 14.0 in wide, 19.5 in deep, UV-resistant, 450°F polymer with Microban antimicrobial additive.\u003c\/li\u003e\n\u003cli\u003eQuality control: helium leak test and 500 psi air pressure test at the factory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSold alone, a coil has no efficiency rating of its own and is not eligible for the LogisVert grant. Final performance depends on the outdoor unit and indoor unit it is matched with.\u003c\/p\u003e\n\u003ch3\u003eInstallation, done by AirGreen\u003c\/h3\u003e\n\u003cp\u003eA family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. For a heat pump project on an electric furnace, we:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003evisit the house free of charge, measure the plenum and note where the lines and drain run;\u003c\/li\u003e\n\u003cli\u003econfirm the match between the coil and the proposed outdoor unit;\u003c\/li\u003e\n\u003cli\u003eset the coil, braze the copper connections and connect the drain;\u003c\/li\u003e\n\u003cli\u003ecommission the system, in cooling as well as heating.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThis model has a right-hand configuration; if your installation needs the other side, the left-hand HE31930A140A0004AP is available in the same series. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eGet your quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eA free on-site estimate, a detailed written quote and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available: tell us about your central heat pump project.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":67801557369124,"sku":"HE31930A140A0000AP","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HE_SANS_BOITIER_HE31930A140A0000AP_00_CODE_30_CONFIG_DROITE_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082502"},{"product_id":"serpentin-devaporateur-adp-he31930a140a0004ap-a","title":"ADP HE31930A140A0004AP Evaporator A-Coil","description":"\u003ch2\u003eThe right side the first time: a left-hand ADP coil\u003c\/h2\u003e\n\u003ch3\u003eWhy the configuration matters\u003c\/h3\u003e\n\u003cp\u003eAn uncased evaporator coil has to fit the plenum and the installation around it. ADP therefore builds the same A-coil in two configurations: right-hand (code 00) and left-hand (code 04). The HE31930A140A0004AP is the left-hand version. Otherwise, its sheet is that of the right-hand HE31930A140A0000AP: same slab, same expansion valve, same drain pan.\u003c\/p\u003e\n\u003cp\u003eDuring the visit, we look at the plenum, the existing unit and the routing of the lines and drain before choosing the configuration. Ordering the right side from the start avoids returned parts and improvised adjustments on installation day.\u003c\/p\u003e\n\u003ch3\u003eThe HE31930A140A0004AP sheet\u003c\/h3\u003e\n\u003cp\u003eCapacity code 30 stands for 30,000 BTU\/h nominal per ADP nomenclature, and the manufacturer publishes a reference airflow of 1,000 CFM at 30 MBTUH. Its selection table lists the E31 slab in the 18, 24 and 30 MBTUH rows, which makes checking the match with the outdoor unit essential. The copper coil is 13 in high, sits on a pan 14.0 in wide and 19.5 in deep, and weighs 24 lb. It installs upflow or downflow.\u003c\/p\u003e\n\u003cp\u003eIts metering device is a non-bleed TXV that ADP intends for heat pump and air conditioning use on R-410A. It therefore suits adding a central air conditioner as well as a central heat pump set on an electric furnace or air handler.\u003c\/p\u003e\n\u003ch3\u003eThe drain pan and factory testing\u003c\/h3\u003e\n\u003cp\u003eIn a basement mechanical room, the drain pan works all summer. ADP moulds it from UV-resistant, high-temperature (450°F) polymer and adds Microban antimicrobial additive. At the factory, the coil undergoes a helium leak test and a 500 psi air pressure test; the copper connections, including the 3\/4 in ODF suction, are brazed on site.\u003c\/p\u003e\n\u003cp\u003eSold alone, the coil has no efficiency rating of its own and is not eligible for the LogisVert grant: performance depends on the outdoor unit and indoor unit it is matched with.\u003c\/p\u003e\n\u003ch3\u003eInstallation and warranty\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). Our technicians set the coil, adapt the plenum, braze the connections, connect the drain and commission the system, in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eADP covers the coil’s parts for 5 years from installation, and extends that coverage to 10 years under the conditions of its extended warranty. Labour and refrigerant are not part of the manufacturer’s warranty.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free on-site estimate: we confirm the configuration and the match, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":67801574900004,"sku":"HE31930A140A0004AP","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HE_SANS_BOITIER_HE31930A140A0004AP_00_CODE_30_CONFIG_GAUCHE_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082502"},{"product_id":"serpentin-devaporateur-adp-he32936a155a0000ap-a","title":"ADP HE32936A155A0000AP Evaporator A-Coil","description":"\u003ch2\u003eA wide-pan ADP coil for a code 36 central system\u003c\/h2\u003e\n\u003ch3\u003eThree measurements before ordering\u003c\/h3\u003e\n\u003cp\u003eAn uncased evaporator coil has to sit cleanly on the unit that moves the air, whether it is an electric furnace or an air handler. For ADP’s HE32936A155A0000AP, we check three dimensions published by the manufacturer:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003ethe drain pan width, 15.5 in, compared with that of the unit and the plenum;\u003c\/li\u003e\n\u003cli\u003ethe coil height, 15 in, which sets the space needed in the plenum;\u003c\/li\u003e\n\u003cli\u003ethe pan depth, 19.5 in.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eIf the widths differ, we plan a transition in the quote rather than cutting one on installation day. These checks are done during the visit and avoid ordering a part that does not fit. The model installs upflow or downflow, in a right-hand configuration (code 00).\u003c\/p\u003e\n\u003ch3\u003eWhat the HE32936A155A0000AP is\u003c\/h3\u003e\n\u003cp\u003eIt is an A-coil with an E32 copper slab, shipped uncased, weighing 28 lb. Its capacity code 36 stands for 36,000 BTU\/h nominal per ADP nomenclature, and the manufacturer publishes a reference airflow of 1,200 CFM at 36 MBTUH. ADP’s selection table lists this slab in the 24, 30 and 36 MBTUH rows: the exact match is therefore confirmed against the outdoor unit’s documentation, a step we always take.\u003c\/p\u003e\n\u003cp\u003eIts metering device is a non-bleed TXV designed for heat pump and air conditioning use on R-410A. The coil thus suits two-storey and semi-detached homes that want air conditioning, or a central heat pump on their electric furnace. The pan is moulded from UV-resistant, 450°F polymer with Microban antimicrobial additive, and the coil is factory tested with helium and at 500 psi air pressure.\u003c\/p\u003e\n\u003cp\u003eNote: a coil sold alone has no efficiency rating of its own and is not eligible for the LogisVert grant.\u003c\/p\u003e\n\u003ch3\u003eAirGreen’s work\u003c\/h3\u003e\n\u003cp\u003eA family business established in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). After a free on-site estimate and a written quote, our technicians set the coil, build the transition if needed, braze the 3\/4 in ODF suction connection and the other copper connections, connect the drain and commission the system. We also check that the unit’s blower delivers the required airflow.\u003c\/p\u003e\n\u003cp\u003eWe work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. On warranty, ADP covers parts for 5 years from installation, extendable to 10 years under the conditions of its extended warranty; labour is not part of it.\u003c\/p\u003e\n\u003ch3\u003eLet’s move on your project\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBook your free estimate: we take the measurements, confirm the match and give you a written quote, with \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":67801591808292,"sku":"HE32936A155A0000AP","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HE_SANS_BOITIER_HE32936A155A0000AP_00_CODE_36_SERPENTIN_15_PO_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082502"},{"product_id":"serpentin-devaporateur-adp-he34936a155a0000ap-a","title":"ADP HE34936A155A0000AP Evaporator A-Coil","description":"\u003ch2\u003eA 19 in ADP coil for more demanding central systems\u003c\/h2\u003e\n\u003ch3\u003eWho the HE34936A155A0000AP is for\u003c\/h3\u003e\n\u003cp\u003eThis ADP evaporator A-coil, shipped uncased, uses the E34 copper slab. In the manufacturer’s selection table, this slab appears in the 36 and 42 MBTUH rows, and the model’s capacity code is 36, which is 36,000 BTU\/h nominal per ADP nomenclature. It is therefore aimed at central systems in that capacity range, found in large single-family homes, two-storey cottages or enlarged semi-detached homes.\u003c\/p\u003e\n\u003cp\u003eIt sits in the plenum of an electric furnace or air handler and becomes the indoor part of a central air conditioner or central heat pump. ADP states that its HE coils are compatible with air conditioning and heat pumps, and this model has a non-bleed TXV designed for both modes on R-410A. Paired with a heat pump, the same coil heats the house in winter, while the electric furnace stays in place for backup.\u003c\/p\u003e\n\u003ch3\u003eHeight, the first thing to check\u003c\/h3\u003e\n\u003cp\u003eWith a 19 in coil height, the vertical space above the unit becomes the deciding factor. In a finished basement, a beam or a low main duct can limit that space. That is why we measure the plenum at the visit and state in the quote any duct changes needed. The drain pan is 15.5 in wide and 19.5 in deep, and the coil weighs 35 lb.\u003c\/p\u003e\n\u003cp\u003eADP publishes a reference airflow of 1,200 CFM at 36 MBTUH. We check that your unit’s blower can deliver it before confirming the match.\u003c\/p\u003e\n\u003ch3\u003eConstruction and manufacturer warranty\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCopper connections for brazing, including the 3\/4 in ODF suction.\u003c\/li\u003e\n\u003cli\u003eUV-resistant, 450°F polymer drain pan treated with Microban antimicrobial additive.\u003c\/li\u003e\n\u003cli\u003eHelium leak test and 500 psi air pressure test at the factory.\u003c\/li\u003e\n\u003cli\u003eADP 5-year limited parts warranty, extendable to 10 years under the conditions of its extended warranty; labour is not covered by the manufacturer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eLike any coil sold alone, it has no efficiency rating of its own and is not eligible for the LogisVert grant.\u003c\/p\u003e\n\u003ch3\u003eA complete installation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eEstablished in \u003cstrong\u003eMontreal\u003c\/strong\u003e for more than fifteen years, AirGreen is a family business holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. We assess your project on site free of charge, give you a written quote, then our technicians set the coil, braze the connections, connect the drain and commission the system. Before leaving, they check operation in cooling and, where applicable, in heat pump mode. We serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHave us measure your plenum: the estimate is free, the quote is in writing and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":67801611796772,"sku":"HE34936A155A0000AP","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HE_SANS_BOITIER_HE34936A155A0000AP_00_CODE_36_SERPENTIN_19_PO_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082502"},{"product_id":"serpentin-devaporateur-adp-hh57118a185a2102ap-horizontal-1-5-tonnes","title":"ADP HH57118A185A2102AP Horizontal Evaporator Coil | 1.5 Tons","description":"\u003ch2\u003eAdd air conditioning to a horizontal furnace without redoing everything\u003c\/h2\u003e\n\u003cp\u003eIn many condos, plexes and small houses, the electric furnace or air handler does not stand upright in a corner of the basement: it lies on its side, hangs from the ceiling or sits in a crawl space. The \u003cstrong\u003eADP HH57118A185A2102AP horizontal evaporator coil\u003c\/strong\u003e is designed for that position. It is a dedicated horizontal slab, delivered in its cabinet, rated 1.5 tons (18,000 BTU\/h nominal), using R-410A, with a factory-installed piston metering device.\u003c\/p\u003e\n\u003ch3\u003eWhat it is, and who it suits\u003c\/h3\u003e\n\u003cp\u003eThe evaporator coil is the indoor part of a central air conditioner or central heat pump. Placed at the outlet of the air handler, it cools and dries the air flowing through the ductwork; with a heat pump, it also works in heating mode. ADP presents the HH series as compatible with an air conditioner or a heat pump, and as a good choice for replacing the coil of an existing installation. The 1.5-ton size is aimed at small dwellings, plex units and modest bungalows. We always validate the sizing before recommending it.\u003c\/p\u003e\n\u003ch3\u003eA format designed for tight spaces\u003c\/h3\u003e\n\u003cp\u003eThe cabinet measures 22-3\/4 in high, 23 in wide and 10 in deep, and weighs 36 lb. This is the only depth offered in the HH series, an advantage when the unit sits above a suspended ceiling or in a crawl space. The slab accepts air in both directions: the unit can blow through the coil from the left or from the right, which gives more latitude for connecting the existing ductwork. The drain pan is molded from a high-temperature polymer (450°F), UV resistant and treated with Microban.\u003c\/p\u003e\n\u003ch3\u003eIn a Québec house or plex\u003c\/h3\u003e\n\u003cp\u003eHere, most central systems rely on an electric furnace or an air handler. The coil is added to that system: in summer, it removes heat and humidity from the air; in winter, with a heat pump, it distributes the heat captured outdoors, and the furnace takes over during deep cold. One point must be clear, however. Sold alone, the coil does not qualify for the LogisVert grant and has no efficiency rating of its own: performance depends on the outdoor unit and the equipment it is matched with. ADP does not publish a matching list for this model, so we check your equipment before ordering.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation covers\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). After a free on-site estimate and a written quote, our technicians:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003echeck the capacity and refrigerant of the outdoor unit, as well as the piston size;\u003c\/li\u003e\n\u003cli\u003erecover the refrigerant and remove the old coil, if applicable;\u003c\/li\u003e\n\u003cli\u003esecure the cabinet and adapt the transition to the 18-5\/8 x 21-1\/4 in opening;\u003c\/li\u003e\n\u003cli\u003ebraze the 3\/8 and 7\/8 in connections, pressure-test with nitrogen, then pull a vacuum;\u003c\/li\u003e\n\u003cli\u003econnect the condensate drain and commission the system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe install this coil in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate: we confirm compatibility with your furnace and outdoor unit, then you receive a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":67801628901668,"sku":"HH57118A185A2102AP","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HH_HH57118A185A2102AP_00_1_5_T_18_000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082503"},{"product_id":"serpentin-devaporateur-adp-hh58124a225a2102ap-horizontal-2-tonnes","title":"ADP HH58124A225A2102AP Horizontal Evaporator Coil | 2 Tons","description":"\u003ch2\u003eReplace a worn horizontal coil and keep your ductwork\u003c\/h2\u003e\n\u003cp\u003eAn evaporator coil that leaks or has lost its efficiency does not always condemn the whole system. When the R-410A outdoor unit is still in good condition, replacing only the coil can restore normal summer comfort without touching the ductwork. The \u003cstrong\u003eADP HH58124A225A2102AP horizontal coil\u003c\/strong\u003e was designed for this kind of job: ADP presents it as a good choice for replacing existing installations.\u003c\/p\u003e\n\u003ch3\u003eA 2-ton coil for a unit lying on its side\u003c\/h3\u003e\n\u003cp\u003eIt is a dedicated horizontal evaporator slab, delivered in its cabinet, with a nominal capacity of 2 tons (24,000 BTU\/h). It runs on R-410A and the metering device is a factory-installed piston, sized to that nominal capacity. ADP states that the HH series suits a central air conditioner as well as a central heat pump. This size is often found in townhouses, semi-detached homes and bungalows where the electric furnace lies along the basement ceiling or in a mechanical space.\u003c\/p\u003e\n\u003ch3\u003eWhen replacing the coil alone is the right decision\u003c\/h3\u003e\n\u003cp\u003eWe recommend a coil-only replacement when three conditions are met: the outdoor unit works well, it uses R-410A, and its capacity matches the 2-ton size. If the outdoor unit is also reaching the end of its life, it is often better to look at a complete system; in that case, we present both scenarios in the quote. Note also that a coil sold alone does not qualify for the LogisVert grant and has no efficiency rating of its own: performance depends on the combination with the outdoor unit and the air handler.\u003c\/p\u003e\n\u003ch3\u003eThe details that matter on site\u003c\/h3\u003e\n\u003cp\u003eThe cabinet measures 22-3\/4 x 27 x 10 in (H x W x D) and weighs 41 lb. Its 22-5\/8 x 21-1\/4 in opening lets us prepare the transition to the existing unit before installation day. The slab accepts air in either direction, which simplifies the hookup when the old coil was not oriented on the same side. The drain pan, made of high-temperature polymer (450°F), UV resistant and treated with Microban, collects condensate during the cooling season.\u003c\/p\u003e\n\u003ch3\u003eHow we work\u003c\/h3\u003e\n\u003cp\u003eA family business established in Montreal for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. The estimate visit is free and the quote is written. On the day of the work, we recover the refrigerant, remove the old coil, set the new slab, braze the 3\/8 and 7\/8 in connections, pressure-test and pull a vacuum, reconnect the drain, then check operation with the outdoor unit. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSend us a photo of your furnace and of the outdoor unit’s nameplate: we confirm compatibility and schedule the free estimate. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":67801642500388,"sku":"HH58124A225A2102AP","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HH_HH58124A225A2102AP_00_2_T_24_000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082503"},{"product_id":"serpentin-devaporateur-adp-hh59130a265a2102ap-horizontal-2-5-tonnes","title":"ADP HH59130A265A2102AP Horizontal Evaporator Coil | 2.5 Tons","description":"\u003ch2\u003eA 2.5-ton horizontal slab, ready for a central heat pump\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eADP HH59130A265A2102AP evaporator coil\u003c\/strong\u003e is the indoor part that turns a horizontal electric furnace into an air conditioning system, or into a central heat pump if the outdoor unit allows it. It is a dedicated horizontal slab, delivered in its cabinet, rated 2.5 tons (30,000 BTU\/h nominal), using R-410A. ADP declares it compatible with an air conditioner as well as a heat pump.\u003c\/p\u003e\n\u003ch3\u003eThe coil’s role in a central heat pump\u003c\/h3\u003e\n\u003cp\u003eIn summer, the refrigerant flowing through the slab absorbs heat from the air blown by the furnace; moisture condenses on the fins and drains into the pan, molded from a high-temperature polymer (450°F), UV resistant, with Microban. In winter, with a heat pump, the cycle reverses: the slab returns the heat captured outdoors to the ductwork, and the electric furnace tops up as needed. This 2.5-ton size is aimed at mid-size multi-storey houses, once the load has been calculated.\u003c\/p\u003e\n\u003ch3\u003eThe factory-sized piston, explained simply\u003c\/h3\u003e\n\u003cp\u003eThe metering device doses the refrigerant entering the slab. Here, it is a factory-installed piston sized for the nominal 30,000 BTU\/h capacity. According to ADP, the H59 slab covers 2.5 to 4 tons: the piston is therefore what sets this model’s size. Before start-up, we check the requirements of the matched outdoor unit and adjust if needed. ADP does not publish a matching list for this coil, and a coil sold alone has no efficiency rating of its own; it does not qualify for the LogisVert grant either.\u003c\/p\u003e\n\u003ch3\u003eFor mechanical rooms and finished basements\u003c\/h3\u003e\n\u003cp\u003eIn many Québec homes, the furnace was laid along the ceiling of the mechanical room to free up floor space when the basement was finished. The 22-3\/4 x 31 x 10 in (H x W x D), 44 lb cabinet fits this type of installation, provided it is well supported. Air can pass through the slab in either direction, which leaves more latitude to place the coil on the most practical side. It cannot, however, be mounted vertically.\u003c\/p\u003e\n\u003ch3\u003eAirGreen’s installation, step by step\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate, inspection of the furnace, the outdoor unit and the refrigerant line route.\u003c\/li\u003e\n\u003cli\u003eWritten quote, with matching options where applicable.\u003c\/li\u003e\n\u003cli\u003eCoil installation, transition to the 26-5\/8 x 21-1\/4 in opening, brazing of the 3\/8 and 7\/8 in connections.\u003c\/li\u003e\n\u003cli\u003ePressure test, vacuum, drain connection and commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years (RBQ licence 5645-9605-01: ventilation, refrigeration and electrical). We serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLet’s talk about your heat pump or air conditioning project: the estimate is free, the quote is written and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":67801653281060,"sku":"HH59130A265A2102AP","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HH_HH59130A265A2102AP_00_2_5_T_30_000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082503"},{"product_id":"serpentin-devaporateur-adp-hh59136a265a2102ap-horizontal-3-tonnes","title":"ADP HH59136A265A2102AP Horizontal Evaporator Coil | 3 Tons","description":"\u003ch2\u003eThree tons of cooling on a horizontal furnace, with a well-planned drain\u003c\/h2\u003e\n\u003cp\u003eWhen the electric furnace lies along the ceiling of a finished basement or in a mechanical space, the coil on top of it works above living areas. The \u003cstrong\u003eADP HH59136A265A2102AP horizontal coil\u003c\/strong\u003e addresses this situation with a 10 in deep cabinet, a molded drain pan and bi-directional airflow. It is a 3-ton (36,000 BTU\/h nominal) R-410A slab for a central air conditioner or a central heat pump.\u003c\/p\u003e\n\u003ch3\u003eWhat you are installing\u003c\/h3\u003e\n\u003cp\u003eThis evaporator coil is delivered in its cabinet, ready to attach to the outlet of a horizontal electric furnace or air handler. Its metering device is a factory-installed piston. According to ADP, the H59 slab covers 2.5 to 4 tons, and it is the piston size, intended for 36,000 BTU\/h, that makes this model a 3-ton coil. This size suits single-family houses and plexes whose ductwork serves several rooms on more than one level.\u003c\/p\u003e\n\u003ch3\u003eCondensate, a detail that matters\u003c\/h3\u003e\n\u003cp\u003eOn a humid July day in \u003cstrong\u003eMontreal\u003c\/strong\u003e, a coil removes a lot of water from the air. The HH59136A265A2102AP’s condensate falls into a molded pan made of high-temperature polymer (450°F), UV resistant and treated with Microban, then flows to the drain. We install a trap on the drain and, when the unit sits above a finished room, we recommend an auxiliary pan under the assembly. It is a simple precaution that protects ceilings.\u003c\/p\u003e\n\u003ch3\u003eAir conditioner or heat pump\u003c\/h3\u003e\n\u003cp\u003eADP declares the HH series compatible with both. With a central heat pump, the same coil distributes heat in winter, and the electric furnace tops up during deep cold. One clarification is needed: sold alone, the coil has no efficiency rating of its own and does not qualify for the LogisVert grant. Performance depends on the matched outdoor unit and air handler, and ADP does not publish a matching list for this model. We therefore check your equipment before any order.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen does\u003c\/h3\u003e\n\u003cp\u003eA family business established in Montreal for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). After the free on-site estimate, you receive a written quote that spells out the work: refrigerant recovery and removal of the old coil if applicable, installation and support of the 44 lb cabinet, transition to the 26-5\/8 x 21-1\/4 in opening, brazing of the 3\/8 and 7\/8 in connections, pressure test, vacuum, drain, then commissioning. We work in \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and throughout \u003cstrong\u003eMontreal\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate: we check your furnace, your outdoor unit and the drain location, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":67801665470756,"sku":"HH59136A265A2102AP","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HH_HH59136A265A2102AP_00_3_T_36_000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082502"},{"product_id":"serpentin-devaporateur-adp-hh61148a365a2102ap-horizontal-4-tonnes","title":"ADP HH61148A365A2102AP Horizontal Evaporator Coil | 4 Tons","description":"\u003ch2\u003eA 4-ton horizontal coil for large houses and ceiling installations\u003c\/h2\u003e\n\u003cp\u003eThe larger the house, the more generous the evaporator coil must be, and the more carefully its location must be planned. The \u003cstrong\u003eADP HH61148A365A2102AP horizontal coil\u003c\/strong\u003e offers 4 tons (48,000 BTU\/h nominal) in a 10 in deep cabinet, designed to connect to an electric furnace or air handler installed lying down. It runs on R-410A and, according to ADP, suits an air conditioner as well as a heat pump.\u003c\/p\u003e\n\u003ch3\u003eA long, shallow format\u003c\/h3\u003e\n\u003cp\u003eThe cabinet measures 22-3\/4 in high, 41 in wide and 10 in deep, and weighs 57 lb. It houses an H61 slab, which covers 3.5 to 5 tons according to ADP; the factory-installed piston, sized for 48,000 BTU\/h, sets this model’s size. Air can pass through the slab in either direction, and the drain pan is molded from a high-temperature polymer (450°F), UV resistant, with Microban. The refrigerant connections are 3\/8 in for the liquid line and 7\/8 in for the suction line.\u003c\/p\u003e\n\u003ch3\u003eWhere it is used\u003c\/h3\u003e\n\u003cp\u003eThis size is installed in large houses whose horizontal furnace serves several floors, but also in offices and small shops where the unit is placed in the ceiling to free up usable space. In every case, the coil does only part of the job: its performance depends on the outdoor unit and air handler it is matched with. Sold alone, it has no efficiency rating of its own and does not qualify for the LogisVert grant. ADP does not publish a matching list for this model, so we validate compatibility before ordering.\u003c\/p\u003e\n\u003ch3\u003ePlanning access and support\u003c\/h3\u003e\n\u003cp\u003eA 41 in, 57 lb cabinet hung above a finished room requires planning. We provide solid supports, an access panel for service and a drain with a trap, and we recommend an auxiliary pan under the unit. These details are set out in the quote, before the work begins.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work. After a free on-site estimate and a written quote, we recover the refrigerant from the old system if applicable, install the coil and the transition to the 36-5\/8 x 21-1\/4 in opening, braze the connections, pressure-test and pull a vacuum, then commission the system with the outdoor unit. We serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor a house or business that calls for a 4-ton coil, ask for your free estimate: you will receive a written quote, and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":67801677889828,"sku":"HH61148A365A2102AP","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HH_HH61148A365A2102AP_00_4_T_48_000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082503"},{"product_id":"serpentin-devaporateur-adp-hh66160a425a2102ap-horizontal-5-tonnes","title":"ADP HH66160A425A2102AP Horizontal Evaporator Coil | 5 Tons","description":"\u003ch2\u003eFive tons of cooling on a horizontal furnace, in a 10 in cabinet\u003c\/h2\u003e\n\u003cp\u003eLarge houses whose electric furnace lies along the ceiling of a mechanical room need a coil that matches their ductwork without eating into the space. The \u003cstrong\u003eADP HH66160A425A2102AP horizontal coil\u003c\/strong\u003e houses a 5-ton (60,000 BTU\/h nominal) slab in a cabinet 22-3\/4 in high and 10 in deep. It runs on R-410A, and ADP declares it compatible with an air conditioner as well as a heat pump.\u003c\/p\u003e\n\u003ch3\u003eA cased coil, ready to connect\u003c\/h3\u003e\n\u003cp\u003eThe coil arrives in its own cabinet with an embossed finish, with a drain pan molded from a high-temperature polymer (450°F), UV resistant and treated with Microban. The H66 slab covers 3 to 5 tons according to ADP; the factory-installed piston, sized for 60,000 BTU\/h, sets this model’s size. Air passes through the slab in either direction, which simplifies the hookup to the existing unit. ADP presents it as a good choice for replacing coils on existing installations.\u003c\/p\u003e\n\u003ch3\u003eFive tons, when it is truly needed\u003c\/h3\u003e\n\u003cp\u003eBigger is not always better. A system too large for the house starts and stops often and removes humidity less effectively, which you feel during \u003cstrong\u003eMontreal\u003c\/strong\u003e’s humid summers. Before recommending this size, we calculate the house’s cooling and heating load. Remember too that the coil alone has no efficiency rating and does not qualify for the LogisVert grant: performance depends on the matched outdoor unit and air handler. ADP does not publish a matching list for this model, so we check your equipment before ordering.\u003c\/p\u003e\n\u003ch3\u003eHandling and placement\u003c\/h3\u003e\n\u003cp\u003eAt 47 in wide and 75 lb, the cabinet takes two people to handle and rests on solid supports. Its 42-5\/8 x 21-1\/4 in opening guides the fabrication of the transition to the unit. When the assembly sits above a finished room, we recommend an auxiliary pan and an access panel for service.\u003c\/p\u003e\n\u003ch3\u003eWith AirGreen, from load calculation to start-up\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). The on-site estimate is free and the quote is written. Our technicians remove the old coil after recovering the refrigerant, install the new one, braze the 3\/8 and 7\/8 in connections, pressure-test and pull a vacuum, connect the drain, then commission the system. Remember afterwards to register the warranty with ADP within 90 days. We serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for your free estimate and a load calculation for your house. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":67801678643492,"sku":"HH66160A425A2102AP","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HH_HH66160A425A2102AP_00_5_T_60_000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082503"}],"url":"https:\/\/airgreen.ca\/en\/collections\/serpentin-d-evaporateur-adp-installation-a-montreal-laval-longueuil-rive-sud-et-rive-nord.oembed","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}