{"title":"TCL APEX XS Zinc White Central Heat Pump | Installation in Greater Montreal","description":null,"products":[{"product_id":"thermopompe-centrale-tcl-apex-xs-blanc-2-tonnes-24000-btu","title":"TCL APEX XS Central Heat Pump (White) | 2 Tons - 24000 BTU","description":"\u003ch2\u003eReplace an Aging Central System Without Renovating the House\u003c\/h2\u003e\n\u003cp\u003eMost of the central systems we replace in \u003cstrong\u003eMontreal\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e do not fail all at once. They gradually wear down: bills rise, the upper floor no longer keeps up, the compressor becomes noisy, and eventually a technician says that the repair costs more than the unit is worth. That is when the question truly arises—and when the \u003cstrong\u003e2-ton TCL APEX XS central heat pump\u003c\/strong\u003e, in Zinc White finish, becomes a serious answer.\u003c\/p\u003e\n\u003cp\u003eWhat sets it apart is not a spectacular innovation, but a very practical feature: it retains \u003cstrong\u003e100% of its rated capacity down to -15°C\u003c\/strong\u003e, and it integrates with an existing duct network without requiring it to be rebuilt.\u003c\/p\u003e\n\n\u003ch3\u003eWhat “retrofit” Means Technically\u003c\/h3\u003e\n\u003cp\u003eA central system consists of an outdoor unit and an air handler connected to the ductwork. In a conventional replacement, both are changed. The \u003cstrong\u003eAPEX XS\u003c\/strong\u003e offers three configurations, and that is where the savings come in:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eWith its own air handler\u003c\/strong\u003e — the complete configuration, when the existing unit is also nearing the end of its service life.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAs a retrofit on an existing furnace\u003c\/strong\u003e — electric, gas, or dual-fuel. The furnace retains its backup role during very cold weather, while the heat pump provides the primary heating for the rest of the year.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWith a coil in a cabinet\u003c\/strong\u003e — when only the heat-pump section needs to be replaced.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eIn the postwar bungalows of \u003cstrong\u003eSaint-Laurent\u003c\/strong\u003e, \u003cstrong\u003eAhuntsic\u003c\/strong\u003e, and \u003cstrong\u003eBrossard\u003c\/strong\u003e, where the furnace was often replaced more recently than the heat pump, the second option avoids several thousand dollars in work and shortens the project by a full day.\u003c\/p\u003e\n\n\u003ch3\u003eCertified Figures, Without Interpretation\u003c\/h3\u003e\n\u003cp\u003eValues from the NEEP cold-climate heat-pump directory, based on AHRI-certified testing:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e24,000 BTU\/h at 8.3°C\u003c\/strong\u003e — COP 3.80\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24,000 BTU\/h at -8°C\u003c\/strong\u003e — COP 2.50\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24,000 BTU\/h at -15°C\u003c\/strong\u003e — COP 1.85\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e13,300 BTU\/h at -30°C\u003c\/strong\u003e at maximum capacity — COP 1.20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe same figure appears three times in the first three lines. That is unusual, and it changes the conversation about sizing: a central system that loses nothing between 8°C and -15°C can be sized according to the building’s actual load rather than oversized “for winter.” The backup heat then starts only below -15°C, which represents a limited fraction of the heating hours in a season in \u003cstrong\u003eGreater Montreal\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eSeasonal efficiency follows suit: \u003cstrong\u003e19.0 SEER2\u003c\/strong\u003e, \u003cstrong\u003e12.0 EER2\u003c\/strong\u003e, and \u003cstrong\u003e10.0 HSPF2\u003c\/strong\u003e. This HSPF2 rating of 10.0 is the highest among the four capacities in the series.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir handler\u003c\/strong\u003e: H24APH20UDE — \u003cstrong\u003eOutdoor unit\u003c\/strong\u003e: H24SDH20XQC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI certificate\u003c\/strong\u003e: 218453815 — \u003cstrong\u003eENERGY STAR number\u003c\/strong\u003e: 4622454\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e: \u003cstrong\u003eR-32\u003c\/strong\u003e, 68.1 oz charge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated airflow\u003c\/strong\u003e: 835 CFM — \u003cstrong\u003eexternal static pressure\u003c\/strong\u003e: 0.58 in. nominal, 0.8 in. maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor power supply\u003c\/strong\u003e: 220 V — \u003cstrong\u003eMCA 19 A\u003c\/strong\u003e, \u003cstrong\u003eMOP 30 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePiping\u003c\/strong\u003e: 3\/8 in. liquid, 3\/4 in. gas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSound level\u003c\/strong\u003e: 45 dB(A) indoors, 53 dB(A) outdoors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir-handler dimensions\u003c\/strong\u003e: 21.00 x 21.00 x 46.44 in. (C cabinet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor-unit dimensions\u003c\/strong\u003e: 38.50 x 16.56 x 31.63 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating range\u003c\/strong\u003e: down to -30°C — \u003cstrong\u003ecooling\u003c\/strong\u003e: up to 55°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR cold-climate certification\u003c\/strong\u003e: yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe air handler supports three installation positions—\u003cstrong\u003eupflow vertical, left horizontal, and right horizontal\u003c\/strong\u003e—which addresses most low-basement or space-constrained mechanical-room situations. Switching to right-horizontal installation simply requires repositioning the condensate pan, an operation provided for by the manufacturer.\u003c\/p\u003e\n\n\u003ch2\u003eStatic Pressure: The Data That Determines a Central System’s Success\u003c\/h2\u003e\n\u003cp\u003eThis is the point we explain most often because it determines real comfort far more than the stated capacity.\u003c\/p\u003e\n\u003cp\u003eAn air handler must overcome the resistance of the \u003cstrong\u003eductwork\u003c\/strong\u003e. The APEX XS is rated for \u003cstrong\u003e0.58 in. of water column\u003c\/strong\u003e under nominal conditions, with a margin up to \u003cstrong\u003e0.8 in.\u003c\/strong\u003e In a properly sized network, with sufficient return-air capacity and clean filters, this margin is comfortable. In an undersized, overly restrictive, or obstructed network, the reality is different: airflow drops, the heat exchanger cannot transfer heat properly, and the measured efficiency bears little resemblance to the technical specifications.\u003c\/p\u003e\n\u003cp\u003eBefore recommending a central system, we therefore measure the static pressure of the existing network. This measurement sometimes leads to an unpleasant conclusion—we may need to add a return-air duct, correct a reduction, or replace a section of ductwork—but it avoids the scenario in which a client pays for a high-performance unit and gets mediocre results. A clean \u003cstrong\u003e18 x 20 filter\u003c\/strong\u003e is also part of the equation; an overly restrictive filter alone can add significant resistance.\u003c\/p\u003e\n\n\u003ch3\u003eA $2,880 Incentive\u003c\/h3\u003e\n\u003cp\u003eThis model appears on the list of eligible equipment for Hydro-Québec’s \u003cstrong\u003eLogisVert\u003c\/strong\u003e program. For an owner-occupied existing home, the incentive reaches \u003cstrong\u003e$2,880\u003c\/strong\u003e. In new construction, it increases to $3,360.\u003c\/p\u003e\n\u003cp\u003eThe application must be submitted within \u003cstrong\u003enine months\u003c\/strong\u003e of installation, and it applies to a specific combination of indoor and outdoor units identified by its AHRI certificate. We verify eligibility before the work and prepare the required documents. Because the lists and amounts are reviewed periodically, we always confirm the exact figure at the time of quoting.\u003c\/p\u003e\n\n\u003ch3\u003eWhat R-32 Means on the Job Site\u003c\/h3\u003e\n\u003cp\u003eThe APEX XS operates with \u003cstrong\u003eR-32\u003c\/strong\u003e, an A2L-classified refrigerant with a significantly lower global-warming potential than R-410A. The unit also includes a built-in \u003cstrong\u003eR-32 leak detector\u003c\/strong\u003e, as well as a drain-pan heater and compressor heater.\u003c\/p\u003e\n\u003cp\u003eFor the installer, this means dedicated tools, a thorough vacuum process, and strict adherence to the additional-charge requirements based on piping length. Our teams are trained to work with these refrigerants. This is not merely a compliance detail: an incorrectly adjusted charge in an R-32 central system results in a loss of capacity that will appear precisely when the first severe cold snap arrives.\u003c\/p\u003e\n\n\u003ch3\u003eCompatibility and Controls\u003c\/h3\u003e\n\u003cp\u003eThe system is compatible with \u003cstrong\u003estandard 24 VAC thermostats\u003c\/strong\u003e, with RS485 communication. In practical terms, a client can keep an existing thermostat that works well or choose a more advanced control. \u003cstrong\u003eWi-Fi connectivity\u003c\/strong\u003e is available as an option with the XK-120D4 module; it is not installed as standard. We prefer to state this clearly rather than have the client discover it after installation.\u003c\/p\u003e\n\n\u003ch3\u003eWhy AirGreen\u003c\/h3\u003e\n\u003cp\u003eA central heat pump is not a product that is simply installed; it is a system integrated into an existing building, with its \u003cstrong\u003eductwork\u003c\/strong\u003e, electrical panel, furnace, and space constraints. At \u003cstrong\u003eAirGreen\u003c\/strong\u003e, we measure static pressure, verify electrical capacity, examine return-air paths, and assess the condition of the network before recommending a capacity.\u003c\/p\u003e\n\u003cp\u003eWe also say when the duct network needs to be corrected, even if that increases the quote. It is the only way to achieve in the field the performance listed in the specifications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact AirGreen for a complete assessment of your central system and a detailed quote for the 2-ton TCL APEX XS\u003c\/strong\u003e in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"TCL","offers":[{"title":"Default Title","offer_id":56286077288740,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_CENTRALE_TCL_APEX_XS_R32_ZINC_WHITE_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_c7f6fed8-bcbc-4e33-98da-ffb37d81873e.png?v=1790972907"},{"product_id":"thermopompe-centrale-tcl-apex-xs-blanc-3-tonnes-36000-btu","title":"TCL APEX XS Central Heat Pump (White) | 3 Tons - 36000 BTU","description":"\u003ch2\u003eThree tons for the 1980s home, with the duct system it already has\u003c\/h2\u003e\n\u003cp\u003eThere is a type of building we encounter every week in Quebec: the single-family home built between 1975 and 1995, heated with electricity or gas, equipped with a \u003cstrong\u003educt system\u003c\/strong\u003e designed at a time when central air conditioning was a secondary addition. The homeowner now wants an efficient central heat pump. The duct system, however, has not changed.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3-ton TCL APEX XS central heat pump\u003c\/strong\u003e, in Zinc White finish, is a unit we seriously consider in this context—provided the air-distribution system is treated as a subject in its own right rather than as an installation detail.\u003c\/p\u003e\n\u003ch3\u003eThe 1,200 CFM and what it requires from the duct system\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003e3-ton\u003c\/strong\u003e central system moves \u003cstrong\u003e1,200 CFM\u003c\/strong\u003e of air. That is a considerable amount, and it must circulate through the existing ducts without creating whistling, unbalancing distant rooms, or overworking the fan.\u003c\/p\u003e\n\u003cp\u003eThe usual design rule places airflow at around 400 CFM per ton. A system originally sized for 2-ton air conditioning with modest airflow will not deliver this volume without modification. The symptoms are always the same: an upstairs bedroom that remains lukewarm, air noise at a floor grille, and a filter that clogs abnormally quickly.\u003c\/p\u003e\n\u003cp\u003eThe factor that governs all of this is \u003cstrong\u003eexternal static pressure\u003c\/strong\u003e: \u003cstrong\u003e0.58 in. of water column\u003c\/strong\u003e under rated conditions, with a reserve up to \u003cstrong\u003e0.8 in.\u003c\/strong\u003e We measure this pressure in the existing system before submitting a quote. When the measurement exceeds the unit's allowance, three corrective measures are possible, from least to most expensive:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eadd a return-air duct\u003c\/strong\u003e, often the most cost-effective measure;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ecorrect a poorly executed transition or elbow\u003c\/strong\u003e at the plenum outlet;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ereplace an undersized main duct section\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003e18 x 20 filter\u003c\/strong\u003e is also factored into the calculation. A poorly selected high-efficiency filter adds enough resistance to cancel out part of the available margin.\u003c\/p\u003e\n\u003ch3\u003eCertified performance\u003c\/h3\u003e\n\u003cp\u003eData from the NEEP cold-climate heat pump directory, based on AHRI-certified testing:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e36,000 BTU\/h at 8.3 °C\u003c\/strong\u003e — COP 3.60\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e36,000 BTU\/h at -8 °C\u003c\/strong\u003e — COP 2.30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e36,000 BTU\/h at -15 °C\u003c\/strong\u003e — COP 1.85\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e18,800 BTU\/h at -30 °C\u003c\/strong\u003e at maximum capacity — COP 1.20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFull capacity down to \u003cstrong\u003e-15 °C\u003c\/strong\u003e. For a properly insulated 1,500- to 2,000-square-foot home in the \u003cstrong\u003eLaval\u003c\/strong\u003e or \u003cstrong\u003eNorth Shore\u003c\/strong\u003e area, this means the heat pump handles heating on its own for the vast majority of the season, with supplemental heat needed only during the coldest periods.\u003c\/p\u003e\n\u003cp\u003eSeasonal performance is rated at \u003cstrong\u003e18.0 SEER2\u003c\/strong\u003e, \u003cstrong\u003e11.0 EER2\u003c\/strong\u003e, and \u003cstrong\u003e9.5 HSPF2\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir handler\u003c\/strong\u003e : H36APH20UDE — \u003cstrong\u003eOutdoor unit\u003c\/strong\u003e : H36SDH20XQC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI certificate\u003c\/strong\u003e : 218453817 — \u003cstrong\u003eENERGY STAR number\u003c\/strong\u003e : 4622453\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e: \u003cstrong\u003eR-32\u003c\/strong\u003e, 105.8 oz charge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow\u003c\/strong\u003e: 1,200 CFM — \u003cstrong\u003estatic pressure\u003c\/strong\u003e: 0.58 \/ 0.8 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor power supply\u003c\/strong\u003e: 220 V — \u003cstrong\u003eMCA 30 A\u003c\/strong\u003e, \u003cstrong\u003eMOP 50 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePiping\u003c\/strong\u003e: 3\/8 in. liquid, 3\/4 in. gas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSound level\u003c\/strong\u003e: 52 dB(A) indoors, 54 dB(A) outdoors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir handler dimensions\u003c\/strong\u003e: 21.00 x 21.00 x 46.44 in. (C cabinet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor unit dimensions\u003c\/strong\u003e: 43.13 x 19.44 x 33.75 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupplemental heating kits\u003c\/strong\u003e: 5, 10, or 15 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation positions\u003c\/strong\u003e: upflow vertical, left horizontal, right horizontal\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eThe 30 A electrical jump, to be addressed before everything else\u003c\/h2\u003e\n\u003cp\u003eMoving from 2 to 3 tons increases the \u003cstrong\u003eMCA from 19 to 30 A\u003c\/strong\u003e, with a maximum protection of \u003cstrong\u003e50 A\u003c\/strong\u003e. This is significant in a 1980s home with a 100- or 125-A panel that already powers baseboard heaters, a water heater, and a range.\u003c\/p\u003e\n\u003cp\u003eIf a \u003cstrong\u003esupplemental heating kit\u003c\/strong\u003e is added to the air handler, the requirement increases further. A 10 kW element at 230 V adds approximately 40 A of minimum ampacity and requires its own protection. The total may require an electrical panel or service upgrade—a several-thousand-dollar item that, if discovered during construction, turns a well-managed project into an unpleasant surprise.\u003c\/p\u003e\n\u003cp\u003eWe therefore calculate the electrical load at the time of quoting, not when it is time to connect the unit. When an upgrade is required, it is included in the quoted price.\u003c\/p\u003e\n\u003ch3\u003eThe 3-ton outdoor unit: placement\u003c\/h3\u003e\n\u003cp\u003eAt \u003cstrong\u003e43.13 x 19.44 x 33.75 in\u003c\/strong\u003e and 75 kg, the outdoor unit requires a stable base and proper clearances—the manufacturer requires at least 12 in. in front of the air intake and 40 in. on the air outlet side. Against a garage wall, between two closely spaced houses, or in a narrow backyard, these clearances must be verified on-site.\u003c\/p\u003e\n\u003cp\u003eRaising the unit above the snow is essential in Quebec. A unit installed directly on a slab at ground level accumulates defrost ice beneath the heat exchanger, eventually blocking the fan and triggering faults in the middle of winter.\u003c\/p\u003e\n\u003ch3\u003e$4,320 in financial assistance\u003c\/h3\u003e\n\u003cp\u003eThis model is eligible for Hydro-Québec's \u003cstrong\u003eLogisVert\u003c\/strong\u003e program, with assistance of \u003cstrong\u003e$4,320\u003c\/strong\u003e for an existing-home owner and $5,040 for new construction. This amount can genuinely change the cost-effectiveness of replacing a central system.\u003c\/p\u003e\n\u003cp\u003eThe application must be submitted within \u003cstrong\u003enine months\u003c\/strong\u003e of installation and is based on the certified indoor-outdoor combination. We verify eligibility before the work, prepare the application, and guide the customer through final submission. The amounts are revised periodically; we confirm the amount in effect when the quote is prepared.\u003c\/p\u003e\n\u003ch3\u003eMistakes to avoid when replacing a central system\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eReuse the old unit's capacity without recalculating.\u003c\/strong\u003e A system installed twenty-five years ago was often oversized, and the house has probably been insulated or had its windows replaced since then. Reusing the same capacity perpetuates the error.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIgnore the return-air paths.\u003c\/strong\u003e This is the most common cause of imbalance between floors and the least expensive issue to correct during the work.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChoose the outdoor location based on ease of connection.\u003c\/strong\u003e The shortest route is not always the one that meets clearance requirements or minimizes disruption to neighbors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSet the airflow only once, in cooling mode.\u003c\/strong\u003e Heating and cooling requirements differ; balancing must be checked in both modes.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eWhy AirGreen\u003c\/h3\u003e\n\u003cp\u003eWe have been working on central \u003cstrong\u003eHVAC\u003c\/strong\u003e systems in existing buildings for years, and most of our value is delivered before installation: static pressure measurement, inspection of \u003cstrong\u003eductwork\u003c\/strong\u003e and return-air paths, heating-load calculation, complete electrical verification including auxiliary heat, validation of outdoor clearances, and review of available assistance programs.\u003c\/p\u003e\n\u003cp\u003eA customer who receives a quote from AirGreen knows what they are buying, including the corrections required to their ductwork. It is less sales-oriented than a round-number price, and considerably more reliable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact AirGreen for an assessment of your ductwork and a complete quote for the 3-ton TCL APEX XS\u003c\/strong\u003e in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"TCL","offers":[{"title":"Default Title","offer_id":56286077321508,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_CENTRALE_TCL_APEX_XS_R32_ZINC_WHITE_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_641da474-5b45-4c5e-aa88-147bf3ad6e3f.png?v=1790972884"},{"product_id":"thermopompe-centrale-tcl-apex-xs-blanc-4-tonnes-48000-btu","title":"TCL APEX XS Central Heat Pump (White) | 4 Tons - 48000 BTU","description":"\u003ch2\u003eFour tons: the format for large homes and multigenerational households\u003c\/h2\u003e\n\u003cp\u003eAt \u003cstrong\u003e4 tons\u003c\/strong\u003e, a central heat pump no longer serves just a dwelling: it covers an entire building, often spread across several levels, sometimes occupied by two households with different habits. The \u003cstrong\u003e4-ton TCL APEX XS central heat pump\u003c\/strong\u003e, in Zinc White finish, is intended for these situations — homes of 2,500 square feet or more, multigenerational homes, cottages with fully finished basements, and small two-unit buildings on a single system.\u003c\/p\u003e\n\u003cp\u003eSwitching to this format brings a visible hardware change: the outdoor unit adopts a two-fan vertical configuration, and its installation requirements are entirely different from those of the smaller capacities.\u003c\/p\u003e\n\u003ch3\u003eThe vertical outdoor unit: an inverted space constraint\u003c\/h3\u003e\n\u003cp\u003eAt \u003cstrong\u003e40.69 x 16.13 x 52.69 in.\u003c\/strong\u003e and approximately 100 kg, the 4-ton outdoor unit is tall and relatively slim. That is good news in tight spaces: it occupies a ground footprint comparable to that of a 3-ton unit while delivering 50% more capacity.\u003c\/p\u003e\n\u003cp\u003eBut height creates its own requirements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eA perfectly level base.\u003c\/strong\u003e A tall unit installed on a slab that shifts with freeze-thaw cycles transmits vibrations and stresses the connections. We favor a stable base isolated from the building.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProper air-discharge clearance.\u003c\/strong\u003e The manufacturer requires at least 40 in. on the discharge side. A unit blowing toward a wall two feet away recirculates its own air and loses capacity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWind must be taken into account.\u003c\/strong\u003e A large vertical surface exposed at the corner of a building on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e is subject to real wind loads. Secure mounting matters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAccess for servicing.\u003c\/strong\u003e Service panels must remain accessible with the unit in place.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertified performance\u003c\/h3\u003e\n\u003cp\u003eNEEP cold-climate heat pump directory values, based on AHRI-certified tests:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e48,000 BTU\/h at 8.3 °C\u003c\/strong\u003e — COP 3.60\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e48,000 BTU\/h at -8 °C\u003c\/strong\u003e — COP 2.30\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e48,000 BTU\/h at -15 °C\u003c\/strong\u003e — COP 1.85\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e24,000 BTU\/h at -30 °C\u003c\/strong\u003e at maximum capacity — COP 1.20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe residual capacity at \u003cstrong\u003e-30 °C\u003c\/strong\u003e deserves attention: \u003cstrong\u003e24,000 BTU\/h\u003c\/strong\u003e, equivalent to a complete 2-ton system operating at its rated capacity. Even in the harshest cold experienced in \u003cstrong\u003eGreater Montreal\u003c\/strong\u003e, the heat pump still handles half the heating load of a large home. The backup supplements rather than replaces it, and the savings show on the bill.\u003c\/p\u003e\n\u003cp\u003eSeasonal performance: \u003cstrong\u003e18.0 SEER2\u003c\/strong\u003e, \u003cstrong\u003e11.0 EER2\u003c\/strong\u003e, \u003cstrong\u003e9.5 HSPF2\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical data sheet\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir handler\u003c\/strong\u003e : H48APH20UDE — \u003cstrong\u003eOutdoor unit\u003c\/strong\u003e : H48SDH20XQC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI certificate\u003c\/strong\u003e : 218453819 — \u003cstrong\u003eENERGY STAR number\u003c\/strong\u003e : 4622452\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e: \u003cstrong\u003eR-32\u003c\/strong\u003e, 123.5 oz charge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow\u003c\/strong\u003e: 1,530 CFM — \u003cstrong\u003estatic pressure\u003c\/strong\u003e: 0.58 \/ 0.8 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor power supply\u003c\/strong\u003e: 220 V — \u003cstrong\u003eMCA 36 A\u003c\/strong\u003e, \u003cstrong\u003eMOP 60 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePiping\u003c\/strong\u003e: 3\/8 in. liquid, 7\/8 in. gas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSound level\u003c\/strong\u003e: 52 dB(A) indoors, 53 dB(A) outdoors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir handler dimensions\u003c\/strong\u003e: 24.50 x 21.00 x 56.00 in. (D cabinet)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilter\u003c\/strong\u003e: 22 x 20 — \u003cstrong\u003eSupplemental heat kits\u003c\/strong\u003e: 5, 10, 15, or 20 kW\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eENERGY STAR Cold Climate certification\u003c\/strong\u003e: yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTwo elements change compared with the 2- and 3-ton models. Air handling moves to the \u003cstrong\u003eD cabinet\u003c\/strong\u003e, which is wider and taller: in a basement with a low ceiling or a cramped mechanical room, the \u003cstrong\u003e56 in.\u003c\/strong\u003e height must be checked with a tape measure before ordering, including plenums. And the \u003cstrong\u003egas piping increases to 7\/8 in.\u003c\/strong\u003e, a diameter that is difficult to bend and requires a planned route with generous bend radii.\u003c\/p\u003e\n\u003ch2\u003eDual-household: one central system, two different comfort preferences\u003c\/h2\u003e\n\u003cp\u003eA dual-household configuration is the one that creates the most disappointment when it is poorly addressed. One system, one thermostat, two households that cannot agree on the temperature: the unit's capacity changes nothing.\u003c\/p\u003e\n\u003cp\u003eThe options we consider in these cases:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eMotorized zoning\u003c\/strong\u003e on the \u003cstrong\u003eductwork\u003c\/strong\u003e, with separate dampers and thermostats. This is the most advanced solution, and the unit's \u003cstrong\u003e0.8 in.\u003c\/strong\u003e static-pressure capacity then becomes critical, since closing dampers increases system resistance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCareful balancing\u003c\/strong\u003e with manual dampers adjusted once and for all, when preference differences are moderate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA supplemental wall-mounted unit\u003c\/strong\u003e in the secondary dwelling, when the duct network does not allow proper balancing.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eWe address this issue before the sale. A properly installed 4-ton central system in an unzoned dual-household home produces mixed results, and it is not the machine's fault.\u003c\/p\u003e\n\u003ch3\u003e$5,760 in financial assistance\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec’s \u003cstrong\u003eLogisVert\u003c\/strong\u003e program provides \u003cstrong\u003e$5,760\u003c\/strong\u003e for this model to a homeowner in an existing residence, and $6,720 for new construction. At this level, the incentive covers a substantial portion of the equipment cost.\u003c\/p\u003e\n\u003cp\u003eThe application must be submitted within \u003cstrong\u003enine months\u003c\/strong\u003e of installation, based on the certified indoor-outdoor combination. We verify eligibility before the work, prepare the application, and support the client through submission. Since the amounts are reviewed periodically, we confirm the applicable amount when preparing the quote.\u003c\/p\u003e\n\u003ch3\u003eThe complete electrical calculation, including supplemental heat\u003c\/h3\u003e\n\u003cp\u003eThe outdoor unit requires \u003cstrong\u003e36 A\u003c\/strong\u003e of minimum ampacity with \u003cstrong\u003e60 A\u003c\/strong\u003e protection. Electric supplemental heat must also be considered if a kit is installed: a 20 kW element at 230 V requires a substantial dedicated power supply on its own.\u003c\/p\u003e\n\u003cp\u003eIn a large home or a multigenerational house, the question is therefore not simply “does the panel have available space?” but rather “can the building’s electrical service handle the total load?” We perform this verification when preparing the quote, using a load calculation in accordance with the Code, because the answer can significantly change the project budget.\u003c\/p\u003e\n\u003ch3\u003eMaintaining a system of this capacity\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e22 x 20 filter\u003c\/strong\u003e needs to be replaced or cleaned more often than most people think: a unit moving 1,530 CFM loads its filter quickly. We recommend a monthly check during the season and annual professional maintenance covering the indoor coil, pan and condensate drain, refrigerant charge, outdoor coil, and airflow balancing.\u003c\/p\u003e\n\u003cp\u003eThe condensate drain deserves particular attention on a unit of this size: the amount of water produced during cooling is significant, and a partially clogged drain in a finished basement can have costly consequences.\u003c\/p\u003e\n\u003ch3\u003eWhy AirGreen\u003c\/h3\u003e\n\u003cp\u003e4-ton projects are where constraints add up: electrical capacity, mechanical space, the \u003cstrong\u003eductwork\u003c\/strong\u003e network, outdoor placement, and zoning. At \u003cstrong\u003eAirGreen\u003c\/strong\u003e, we address each one before preparing the estimate and present the client with the necessary corrections rather than an optimistic price.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact AirGreen for a complete technical analysis of your building and a detailed quote for the 4-ton TCL APEX XS\u003c\/strong\u003e in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"TCL","offers":[{"title":"Default Title","offer_id":56286077354276,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_CENTRALE_TCL_APEX_XS_R32_ZINC_WHITE_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_182fef02-286c-478c-872b-541fd02fb6ba.png?v=1790972860"},{"product_id":"thermopompe-centrale-tcl-apex-xs-blanc-5-tonnes-60000-btu","title":"TCL APEX XS Central Heat Pump (White) | 5 Tons - 60000 BTU","description":"\u003ch2\u003eFive tons: what the specifications sheet states, and what the unit delivers\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e5-ton TCL APEX XS central heat pump\u003c\/strong\u003e, in Zinc White finish, is the largest format in the series. It is intended for high-demand buildings: large residences over 3,000 square feet, multifamily buildings served by a shared system, light commercial spaces, and buildings with significant open areas.\u003c\/p\u003e\n\u003cp\u003eLet's begin with a clarification we prefer to provide up front. \u003cstrong\u003eThe manufacturer's specifications sheet calls this model “60,000 BTU\/h,” but the certified nominal capacity is 54,000 BTU\/h\u003c\/strong\u003e, with a peak that can reach 60,000 BTU\/h in cooling mode. The series' commercial designation uses the round number; the AHRI rating, which is used for sizing, is 54,000. Sizing based on 60,000 BTU\/h would result in a unit that is undersized for the intended load.\u003c\/p\u003e\n\u003ch3\u003eThe certified data\u003c\/h3\u003e\n\u003cp\u003eValues from the NEEP cold-climate heat pump directory, based on AHRI-certified tests:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e54,000 BTU\/h at 8.3 °C\u003c\/strong\u003e — COP 3.40\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e54,000 BTU\/h at -8 °C\u003c\/strong\u003e — COP 2.20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e50,000 BTU\/h at -15 °C\u003c\/strong\u003e — COP 1.85\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e25,000 BTU\/h at -30 °C\u003c\/strong\u003e at maximum capacity — COP 1.20\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is the only capacity in the series that shows a slight reduction at \u003cstrong\u003e-15 °C\u003c\/strong\u003e — 50,000 BTU\/h instead of 54,000, a loss of 7.4%. This is modest compared with what most central systems lose at this temperature, but it should be included in the calculation rather than ignored.\u003c\/p\u003e\n\u003cp\u003eSeasonal performance: \u003cstrong\u003e17.0 SEER2\u003c\/strong\u003e, \u003cstrong\u003e10.0 EER2\u003c\/strong\u003e, \u003cstrong\u003e9.5 HSPF2\u003c\/strong\u003e. These are the lowest values in the range, which is normal: with the same heat exchanger capacity, a higher-capacity machine operates closer to its limits. The unit remains certified as \u003cstrong\u003eENERGY STAR Cold Climate\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir handler\u003c\/strong\u003e : H60APH20UDE — \u003cstrong\u003eOutdoor unit\u003c\/strong\u003e : H60SDH20XQC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI certificate\u003c\/strong\u003e : 218453821 — \u003cstrong\u003eENERGY STAR number\u003c\/strong\u003e : 4622451\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant\u003c\/strong\u003e: \u003cstrong\u003eR-32\u003c\/strong\u003e, 134.0 oz charge\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow\u003c\/strong\u003e: 1,800 CFM — \u003cstrong\u003estatic pressure\u003c\/strong\u003e: 0.58 \/ 0.8 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor power supply\u003c\/strong\u003e: 220 V — \u003cstrong\u003eMCA 42 A\u003c\/strong\u003e, \u003cstrong\u003eMOP 60 A\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePiping\u003c\/strong\u003e: 3\/8 in liquid, 7\/8 in gas\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSound level\u003c\/strong\u003e: 53 dB(A) indoors, 54 dB(A) outdoors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir handler dimensions\u003c\/strong\u003e: 24.50 x 21.00 x 56.00 in (D cabinet) — \u003cstrong\u003efilter\u003c\/strong\u003e 22 x 20\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor unit dimensions\u003c\/strong\u003e: 40.69 x 16.13 x 52.69 in\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAuxiliary heat kits\u003c\/strong\u003e: 5, 10, 15, or 20 kW\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eElectricity: the real limiting factor in a 5-ton project\u003c\/h2\u003e\n\u003cp\u003eFor this size, the determining constraint is almost never space or the \u003cstrong\u003eductwork\u003c\/strong\u003e. It is the panel.\u003c\/p\u003e\n\u003cp\u003eThe outdoor unit alone requires \u003cstrong\u003e42 A\u003c\/strong\u003e of minimum ampacity, with \u003cstrong\u003e60 A\u003c\/strong\u003e overcurrent protection. The air handler has its own power supply. And if an auxiliary heat kit is installed—which is common at this capacity—the load increases further: a \u003cstrong\u003e20 kW\u003c\/strong\u003e element at 230 V alone represents a major electrical load, with its own protection.\u003c\/p\u003e\n\u003cp\u003eIn a light commercial building or a multifamily property, the total load may exceed what the existing electrical service can support. Three scenarios then arise:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe service is sufficient\u003c\/strong\u003e—the project proceeds as is, after a load calculation in accordance with the Code.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe panel must be replaced\u003c\/strong\u003e, while the service remains adequate. Moderate cost, short timeline.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe electrical service must be upgraded\u003c\/strong\u003e, which involves the utility, delays, and a significant budget.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eWe determine which of these three situations applies to the building \u003cstrong\u003ebefore\u003c\/strong\u003e preparing the quote. This is the check that prevents a project from stalling halfway through.\u003c\/p\u003e\n\u003ch3\u003eThe 1,800 CFM airflow and the ductwork that must handle it\u003c\/h3\u003e\n\u003cp\u003eOne thousand eight hundred cubic feet per minute is a considerable volume of air. In a light commercial building with generous main ducts, it passes through without difficulty. In a residence whose ductwork was designed for 3 tons, it does not—and the equipment becomes choked, with static pressure well beyond the \u003cstrong\u003e0.8 in.\u003c\/strong\u003e margin.\u003c\/p\u003e\n\u003cp\u003eThe consequence is not merely a loss of efficiency. Insufficient airflow in heating mode raises the heat exchanger temperature and triggers safety controls; in cooling mode, it can cause the indoor heat exchanger to ice up. These are recurring faults caused by the ductwork, not the equipment, and they result in service visits until someone measures the static pressure.\u003c\/p\u003e\n\u003cp\u003eWe carry out this assessment upstream, systematically, for every 4- and 5-ton project.\u003c\/p\u003e\n\u003ch3\u003e$6,480 in financial assistance\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec's \u003cstrong\u003eLogisVert\u003c\/strong\u003e program provides \u003cstrong\u003e$6,480\u003c\/strong\u003e for this model in an existing home, and $7,560 in new construction. This is the highest amount for the entire TCL lineup.\u003c\/p\u003e\n\u003cp\u003eThe application must be submitted within \u003cstrong\u003enine months\u003c\/strong\u003e of installation. It applies to the certified combination H60APH20UDE \/ H60SDH20XQC identified by its AHRI certificate: substituting another indoor unit breaks the combination and jeopardizes eligibility. We validate all of this before ordering and assist with submitting the application. The amounts are reviewed periodically, and we confirm the amount in effect when the quote is prepared.\u003c\/p\u003e\n\u003ch3\u003eLight commercial applications\u003c\/h3\u003e\n\u003cp\u003eAt 5 tons, some installations serve commercial spaces: offices, clinics, retail stores, and training rooms. The considerations differ from residential applications:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOccupancy hours\u003c\/strong\u003e concentrate the load into specific periods, favoring an inverter-driven unit capable of a wide modulation range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal gains\u003c\/strong\u003e—lighting, equipment, and occupants—carry significant weight in the calculation and increase the cooling load relative to the heating load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFresh-air renewal\u003c\/strong\u003e is subject to regulatory requirements and must be treated as a separate load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService continuity\u003c\/strong\u003e matters more: a breakdown in a commercial setting has a direct cost, which often justifies more intensive preventive maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAccordingly, we adapt the load calculation using actual occupancy profiles rather than residential assumptions.\u003c\/p\u003e\n\u003ch3\u003eMaintenance\u003c\/h3\u003e\n\u003cp\u003eA unit of this capacity warrants professional annual maintenance, and semiannual maintenance in commercial use. The program covers cleaning the indoor coil, the \u003cstrong\u003e22 x 20 filter\u003c\/strong\u003e, the condensate pan and drain, checking the \u003cstrong\u003eR-32\u003c\/strong\u003e charge, inspecting the outdoor coil, checking clearances, and measuring airflow.\u003c\/p\u003e\n\u003cp\u003eThe volume of condensate produced during full cooling is significant: a properly sloped, clean drain equipped with an adequate trap is not a minor detail on a 5-ton system.\u003c\/p\u003e\n\u003ch3\u003eWhy AirGreen\u003c\/h3\u003e\n\u003cp\u003e5-ton installations have little tolerance for approximation. The electrical load, \u003cstrong\u003eductwork\u003c\/strong\u003e, outdoor unit placement, and occupancy profile must all be assessed before committing, because an error in any one of these areas results in recurring service costs for years.\u003c\/p\u003e\n\u003cp\u003eAt \u003cstrong\u003eAirGreen\u003c\/strong\u003e, we perform this analysis upfront and present the figures, including the inconvenient ones—such as the difference between the 60,000 BTU\/h stated in the title and the certified 54,000 BTU\/h.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact AirGreen for a complete load analysis, electrical verification, and detailed quote for the 5-ton TCL APEX XS\u003c\/strong\u003e in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"TCL","offers":[{"title":"Default Title","offer_id":56286077583652,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_CENTRALE_TCL_APEX_XS_R32_ZINC_WHITE_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_7792cc5d-4243-45af-8bdf-05a4108e4958.png?v=1790972835"}],"url":"https:\/\/airgreen.ca\/en\/collections\/thermopompe-centrale-tcl-apex-xs-blanc-zinc-installation-grand-montreal.oembed","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}