{"title":"Packaged Heat Pump System Kinghome | Montreal, Laval, Longueuil, South Shore, North Shore","description":null,"products":[{"product_id":"thermopompe-monobloc-kinghome-rooftop-r32-de-3-tonnes-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System Kinghome Rooftop R32 3 Ton | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eA packaged heat pump that adapts to your controls and your ducts\u003c\/h2\u003e\n\u003cp\u003eReplacing the rooftop unit of a commercial space, an office or a multiplex already served by a duct system always raises the same practical questions: how the new equipment will be controlled, how it connects to the ducts in place, and what protection the manufacturer offers. This Kinghome \u003cstrong\u003eRooftop R32 packaged heat pump\u003c\/strong\u003e, from a brand that presents itself as a member of the Gree group (\"a member of GREE group\"), answers those three questions with a programmable controller supplied, several control modes, a fan adjustable to your ducts and side or bottom air supply.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e is all electric: the compressor, the coils and the fan sit in a single outdoor cabinet, usually installed on the roof, which connects to the building's \u003cstrong\u003educt\u003c\/strong\u003e system to deliver heating and cooling. With a nominal capacity of 3 tons (36,000 BTU) and a certified cooling capacity of 34,000 BTU\/h, the KH03TCNHA model suits buildings that want a single unit, with no gas line and no separate indoor unit. Its 208-230 V single-phase supply lets it serve buildings that have no three-phase service.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, an \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor holding RBQ licence 5645-9605-01, we install this model in \u003cstrong\u003eMontreal\u003c\/strong\u003e, in \u003cstrong\u003eLaval\u003c\/strong\u003e, in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. The sections below explain what matters when fitting it into an existing building: the controls, air balancing, the duct connection, then the warranty Kinghome offers.\u003c\/p\u003e\n\u003ch3\u003eThree ways to control the unit\u003c\/h3\u003e\n\u003cp\u003eCompatibility with the controls already in place often decides how far a replacement has to go. Kinghome provides three options, which lets the installation be adapted to the building rather than the other way around. The choice is made during the site visit, based on the equipment already present in the building and on the way the occupants set the temperature day to day.\u003c\/p\u003e\n\u003ch4\u003eThe programmable wired controller supplied\u003c\/h4\u003e\n\u003cp\u003eEvery unit ships with the XE7C-23\/H \u003cstrong\u003eprogrammable wired controller\u003c\/strong\u003e. You have nothing more to buy to set the setpoints and schedule the heating and cooling periods. For a store with fixed opening hours or an office closed on weekends, scheduling brings the unit's operation in line with the hours the space is really occupied. We install the controller where the temperature is representative of the space it serves, away from entrance doors, sunlit storefront windows and heat sources.\u003c\/p\u003e\n\u003ch4\u003eA 24 VAC thermostat\u003c\/h4\u003e\n\u003cp\u003eIf your tenants or your employees are used to a wall thermostat, the unit also accepts \u003cstrong\u003e24 VAC thermostat control\u003c\/strong\u003e. It is a handy option when replacing an old rooftop unit already wired to a thermostat of this type. Before keeping the wall unit in place, we check the condition of the existing wiring, the number of wires available and the thermostat's compatibility with the heating and cooling functions of the new heat pump.\u003c\/p\u003e\n\u003ch4\u003eModbus control for building management\u003c\/h4\u003e\n\u003cp\u003eIn a building whose equipment is tied into a building management system, the \u003cstrong\u003eModbus control\u003c\/strong\u003e offered as an accessory by Kinghome lets the heat pump be integrated into that network. Modbus is a communication protocol widely used in building management. We work out the details with your integrator or your building manager to confirm, before installation, that the accessory meets their needs.\u003c\/p\u003e\n\u003ch3\u003eSix static pressure settings for ducts that are already there\u003c\/h3\u003e\n\u003cp\u003eA duct system never offers the same resistance from one building to the next: length of the runs, number of elbows, type of filter, size of the grilles and diffusers. A fan poorly matched to that resistance gives either too little airflow at the far registers or noise and drafts at the close ones.\u003c\/p\u003e\n\u003cp\u003eThe fan motor on this heat pump is variable-speed and offers \u003cstrong\u003esix static pressure settings\u003c\/strong\u003e. At start-up, we pick the setting that matches the real duct system rather than a theoretical value, then we check air distribution in the different zones of the space. That is especially useful in a retrofit, when the ducts were designed for an older unit and redoing them is out of the question.\u003c\/p\u003e\n\u003cp\u003eIn operation, the unit automatically adjusts its capacity to the setpoint and to indoor and outdoor conditions. It has an Inverter rotary compressor and an electronic expansion valve: rather than running only on or off, it modulates its output, which helps keep the temperature steady in the space.\u003c\/p\u003e\n\u003ch3\u003eSide or bottom connection, without redoing the ducts\u003c\/h3\u003e\n\u003cp\u003eThe duct layout often dictates the choice of a replacement unit. On this heat pump, supply and return air can be connected on the side or through the bottom; you simply reposition the side panel to go from one configuration to the other. Here are three situations we run into regularly.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement on a flat roof:\u003c\/strong\u003e in a commercial space in Montreal or Longueuil, the ducts often drop straight down through the roof. A bottom connection lets those openings be reused, once the roof curb dimensions published by Kinghome have been compared with those of the curb in place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnit on an outdoor stand:\u003c\/strong\u003e for a multiplex in Laval or a South Shore building whose ducts come in through a wall, a side connection avoids adding elbows or new openings. The stand meets the minimum height of 18 in. required by Kinghome.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOffices tied into a management system:\u003c\/strong\u003e in a North Shore building, we keep the existing ducts and link the new heat pump to the management network through the Modbus accessory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn every case the goal is the same: keep the existing duct system when it is in good condition, limit the openings in the roof or in the walls and reduce the scale of the work in occupied spaces.\u003c\/p\u003e\n\u003ch2\u003eCertified data, Kinghome warranty and installation by AirGreen\u003c\/h2\u003e\n\u003ch3\u003ePerformance verified by ENERGY STAR and AHRI\u003c\/h3\u003e\n\u003cp\u003eThe values below come from this model's ENERGY STAR and AHRI certificates. The unit is \u003cstrong\u003eENERGY STAR Cold Climate certified\u003c\/strong\u003e, a designation that takes its cold-weather heating performance into account.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNominal capacity: 3 tons (36,000 BTU)\u003c\/li\u003e\n\u003cli\u003eCertified cooling at 35 °C: 34,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCertified heating at 8.3 °C: 34,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCertified nominal heating at -8.3 °C (17 °F): 21,800 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at -15 °C (5 °F), at maximum compressor speed: 29,000 BTU\/h, with a COP of 1.90\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2 18.0\u003c\/strong\u003e, EER2 11.2 and HSPF2 8.5 (region IV)\u003c\/li\u003e\n\u003cli\u003eAHRI number 218625041 and ENERGY STAR number 4657813\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOne point about the cold-weather figures: the capacity at -8.3 °C is the certified nominal capacity, while the one at -15 °C is measured at maximum compressor speed, under the ENERGY STAR Cold Climate criterion. That is why the value at -15 °C is higher than the one at -8.3 °C: the two measurements are not taken at the same compressor speed. The unit \u003cstrong\u003eheats down to -30 °C\u003c\/strong\u003e (range of -30 °C to 24 °C outdoor) and cools from -5 °C to 52 °C.\u003c\/p\u003e\n\u003ch3\u003eWhat Kinghome builds into the unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInverter rotary compressor, electronic expansion valve and compressor crankcase heater\u003c\/li\u003e\n\u003cli\u003eIntelligent defrost\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eR-32\u003c\/strong\u003e refrigerant, with a charge of 149.9 oz\u003c\/li\u003e\n\u003cli\u003eSalt spray tested equipment\u003c\/li\u003e\n\u003cli\u003eEmergency shut-off switch included\u003c\/li\u003e\n\u003cli\u003eSound pressure of 63 dB(A)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe figures to plan for before installation\u003c\/h3\u003e\n\u003cp\u003eFitting the unit in is not only a matter of controls. Here is the information we check during the site visit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e 208-230 V \/ 1 phase \/ 60 Hz supply, MCA of 35 A and MOP of 40 A. We confirm the capacity available at the panel and the wiring route.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 44 × 35-7\/16 × 49-1\/4 in. (1,120 × 900 × 1,250 mm), in width, depth and height.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 523 lb net and 545 lb gross, to be measured against the load-bearing capacity of the roof or the stand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Kinghome requires the unit to be installed at least 18 in. (45 cm) above any surface, for snow and for defrost water drainage.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe Kinghome warranty and registration\u003c\/h3\u003e\n\u003cp\u003eKinghome publishes a standard warranty of 5 years on parts and the compressor. When the unit is registered with Kinghome, the published warranty goes to 5 years on parts and 7 years on the compressor, under the manufacturer's conditions. Registration therefore makes a real difference to compressor coverage. At the end of the installation, we hand you the information on the unit and walk you through that step so it is not forgotten.\u003c\/p\u003e\n\u003ch3\u003eHow we work in Montreal and the surrounding area\u003c\/h3\u003e\n\u003cp\u003eFrom Laval to Longueuil, from the North Shore to the South Shore, every project starts with a visit to the building. We look at the existing unit, the condition and layout of the ducts, the electrical panel, roof access and the controls already in place. We then give you a quote that spells out the connection method chosen, the type of control selected and the electrical work to plan for.\u003c\/p\u003e\n\u003cp\u003eOn installation day, our team takes care of removing the old unit, setting the new one in place, connecting it to the ducts and to the controls, then start-up: choosing the static pressure setting, programming the controller and checking operation in heating and in cooling. We take the time to show you the controller and its schedules before we leave. To compare this model with the other capacities and brands we install, see our \u003ca href=\"\/en\/collections\/thermopompe-monobloc-installation-partout-a-montreal-laval-longueuil-rive-sud-et-rive-nord\"\u003epackaged heat pumps\u003c\/a\u003e page.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e100% free on-site estimate anywhere in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/strong\u003e To plan the replacement of your rooftop unit or to confirm that this heat pump will work with your existing controls, call AirGreen at \u003cstrong\u003e514 316-2973\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eDocumentation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/Kinghome_Rooftop_R32_Thermopompe_Monobloc_Brochure_AirGreen_FR.pdf\" target=\"_blank\" rel=\"noopener\"\u003eKinghome Rooftop R32 brochure (French)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/Kinghome_Rooftop_R32_Thermopompe_Monobloc_Brochure_AirGreen_EN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eKinghome Rooftop R32 brochure (English)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Kinghome","offers":[{"title":"Default Title","offer_id":56367196078372,"sku":"KH03TCNHA","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_KINGHOME_ROOFTOP_R32_3_TONNES_00_PROFIL_MONTREAL.png?v=1790077147"},{"product_id":"thermopompe-monobloc-kinghome-rooftop-r32-de-5-tonnes-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System Kinghome Rooftop R32 5 Ton | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eAn installation designed for snow, freezing rain and deep cold\u003c\/h2\u003e\n\u003cp\u003eOn a flat roof in Laval or on the North Shore, a heating unit spends the winter under snow, wind and freeze-thaw cycles. In a building with a heavy heating load, the quality of the installation counts as much as the spec sheet. Built by Kinghome, which describes itself as \"a member of GREE group\", this \u003cstrong\u003eRooftop R32 packaged heat pump\u003c\/strong\u003e delivers a rated capacity of 5 tons (60,000 BTU). It brings the compressor, the coils and the fan together in a single outdoor cabinet, and it connects to the building's \u003cstrong\u003educt\u003c\/strong\u003e system for heating as well as cooling.\u003c\/p\u003e\n\u003cp\u003eAll-electric and powered at 208-230 V single-phase, it is \u003cstrong\u003eENERGY STAR Cold Climate certified\u003c\/strong\u003e and \u003cstrong\u003eheats down to -30 °C\u003c\/strong\u003e. AirGreen, an \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor based in Montreal, installs it in stores, workshops, offices and apartment buildings in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. Here, step by step, is how we prepare an installation that takes the Quebec winter into account.\u003c\/p\u003e\n\u003ch3\u003eAt least 18 in. above any surface\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer requires the unit to be installed at least \u003cstrong\u003e18 in. (45 cm) above any surface\u003c\/strong\u003e. That requirement covers two things. First, snow: on a roof as on the ground, it builds up and drifts with the wind, and a unit set too low risks having its outdoor coil blocked. Second, defrost water: in heating mode, the outdoor coil frosts over and the unit has to melt that frost at intervals. This water has to drain away freely instead of freezing under the unit.\u003c\/p\u003e\n\u003cp\u003eIn practice, we plan a pad or a stand that respects this height, taking into account the usual snow accumulation at the chosen spot, the areas where snow gets pushed during snow clearing and the path the meltwater will take. On the ground, that means avoiding the corners where snow piles up, downspout outlets and the spots where ice could get in the way of pedestrians. On a roof, we avoid the low areas where water sits in the spring.\u003c\/p\u003e\n\u003ch3\u003eThe roof curb and the structure\u003c\/h3\u003e\n\u003cp\u003eFor a rooftop installation, Kinghome publishes the dimensions of this unit's \u003cstrong\u003eroof curb\u003c\/strong\u003e. We start from those dimensions to prepare the location: position of the supply and return openings, sealing with the membrane, final height of the unit. When an older unit is already on the roof, we compare the existing curb with the Kinghome one before proposing an approach, and we coordinate the membrane work with your roofer as needed.\u003c\/p\u003e\n\u003cp\u003eWeight is part of the planning too. The unit weighs 628 lb net and 650 lb gross, in a cabinet of 44 × 44 × 49-1\/4 in. (1,120 × 1,120 × 1,250 mm), W × D × H. Depending on the building, we have the capacity of the structure validated, then we plan the lift and the roof access accordingly.\u003c\/p\u003e\n\u003ch3\u003eDefrost and the protections designed for the cold\u003c\/h3\u003e\n\u003cp\u003eIn cold, damp weather, the frost that forms on the outdoor coil gets in the way of heat exchange, so every heat pump has to defrost regularly through the winter. Kinghome equips this model with \u003cstrong\u003eintelligent defrost\u003c\/strong\u003e. That is also why the location has to let the meltwater drain freely under the unit, as explained above.\u003c\/p\u003e\n\u003cp\u003eOther features provided by Kinghome are useful in a northern climate:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea \u003cstrong\u003ecompressor crankcase heater\u003c\/strong\u003e, which keeps the compressor warm while it is stopped;\u003c\/li\u003e\n\u003cli\u003ean Inverter rotary compressor and an electronic expansion valve;\u003c\/li\u003e\n\u003cli\u003eautomatic capacity adjustment based on the setpoint and on indoor and outdoor conditions, which lets the unit follow the temperature swings of a winter day;\u003c\/li\u003e\n\u003cli\u003eequipment tested in salt spray, useful to know in a region where de-icing salts end up everywhere, from parking lots to sidewalks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertified capacities for the coldest days\u003c\/h3\u003e\n\u003cp\u003eIn a building with a heavy heating load, it is the cold-weather capacities that guide the choice of a unit. Here are the certified heating values of the KH05TCNHA model:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eat 8.3 °C: 57,000 BTU\/h;\u003c\/li\u003e\n\u003cli\u003eat -8.3 °C (17 °F): 34,000 BTU\/h, the certified rated capacity;\u003c\/li\u003e\n\u003cli\u003eat -15 °C (5 °F): 51,000 BTU\/h at maximum compressor speed, with a \u003cstrong\u003eCOP of 2.00;\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eheating operating range from -30 °C to 24 °C outdoor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese two lines do not compare directly: the reading at -8.3 °C is the certified rated capacity, while the reading at -15 °C is taken at maximum compressor speed, in line with the ENERGY STAR Cold Climate criterion. That is why the 51,000 BTU\/h obtained at -15 °C exceeds the 34,000 BTU\/h of the rated capacity at -8.3 °C. As for the COP of 2.00, it means that at -15 °C the unit delivers two units of heating energy for every unit of electricity it consumes.\u003c\/p\u003e\n\u003cp\u003eThese values do not replace a load calculation. Choosing a 5 ton unit rests on a calculation of the building's heating load, which we carry out during the site visit, taking into account the insulation, the windows, how the space is used and the doors that open often in winter.\u003c\/p\u003e\n\u003ch3\u003eCooling performance\u003c\/h3\u003e\n\u003cp\u003eIn cooling, the certified capacity is 56,000 BTU\/h at 35 °C, with a \u003cstrong\u003eSEER2 of 18.0\u003c\/strong\u003e and an EER2 of 11.2. The unit cools at outdoor temperatures from -5 °C to 52 °C. Its HSPF2 (region IV) is 8.3. AHRI number 218679546, ENERGY STAR number 4670910.\u003c\/p\u003e\n\u003ch2\u003eElectrical circuit, ducts and commissioning\u003c\/h2\u003e\n\u003ch3\u003eA single-phase 40 A \/ 45 A circuit\u003c\/h3\u003e\n\u003cp\u003eThe heat pump runs on \u003cstrong\u003e208-230 V \/ 1 phase \/ 60 Hz\u003c\/strong\u003e. Single-phase suits buildings that have no three-phase service. The Kinghome spec sheet lists an MCA (minimum circuit ampacity) of \u003cstrong\u003e40 A\u003c\/strong\u003e and an MOP (maximum overcurrent protection) of \u003cstrong\u003e45 A\u003c\/strong\u003e. These two values are what determine the size of the wiring and of the breaker.\u003c\/p\u003e\n\u003cp\u003eBefore confirming the project, we check with you, and with your electrician as needed, the capacity available at the panel, the distance to the unit and the routing of the wiring on the roof. In winter, that route has to stay protected from snow and from snow clearing. An emergency stop switch is included with the unit.\u003c\/p\u003e\n\u003ch3\u003eDucts connected on the side or from below\u003c\/h3\u003e\n\u003cp\u003eKinghome allows the supply and return air to be connected on the side or underneath the unit, simply by moving the side panel. On a roof, connecting from below, through the roof curb, limits the length of duct exposed to the weather. On a ground-level stand, a side connection reaches a wall of the building directly. In both cases, we insulate and seal the outdoor duct sections carefully, since warm air runs through them all winter long.\u003c\/p\u003e\n\u003cp\u003eIts adjustable-speed fan offers six static pressure settings, which we match to the building's duct system. On the control side, a programmable wired controller (XE7C-23\/H) is included, the unit accepts a 24 VAC thermostat and Kinghome offers a Modbus control as an accessory.\u003c\/p\u003e\n\u003ch3\u003eSome examples of buildings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle-storey store in Longueuil:\u003c\/strong\u003e the front door opens all day long in winter and the space is served by a single duct system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWorkshop or small warehouse on the North Shore:\u003c\/strong\u003e a building with no three-phase service, where single-phase power avoids adding a three-phase service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOffices in Laval:\u003c\/strong\u003e a rooftop unit to be replaced, with an existing curb that we compare with the one published by Kinghome.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApartment building in Montreal:\u003c\/strong\u003e ducts already in place and a flat roof on which the unit respects the 18 in. height.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNoise and other useful data\u003c\/h3\u003e\n\u003cp\u003eThe published sound pressure is 68 dB(A). We take it into account to place the unit away from neighbours' windows and from terraces. The unit uses \u003cstrong\u003eR-32\u003c\/strong\u003e refrigerant, with a charge of 204.6 oz.\u003c\/p\u003e\n\u003ch3\u003eThe warranty published by Kinghome\u003c\/h3\u003e\n\u003cp\u003eOn the warranty side, Kinghome publishes standard coverage of 5 years on parts and on the compressor. If the unit is registered with the manufacturer, the published warranty becomes 5 years on parts and 7 years on the compressor, subject to Kinghome's conditions. Once the installation is finished, we show you how to complete that registration.\u003c\/p\u003e\n\u003ch3\u003eInstallation by AirGreen, from the site visit to commissioning\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSite visit and calculation:\u003c\/strong\u003e we assess the building's heating load, the condition of the ducts, the electrical panel, the structure and the roof access.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePreparation:\u003c\/strong\u003e roof curb or stand meeting the 18 in. height, 40 A \/ 45 A circuit, openings for the ducts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e lifting the unit into place, connecting the ducts on the side or from below, electrical hookup and control wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommissioning:\u003c\/strong\u003e matching the fan to the building's duct system, setting the schedules on the controller, tests in heating and in cooling, checking that the defrost water drains properly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf your building calls for a unit of another size, our \u003ca href=\"\/en\/collections\/thermopompe-monobloc-installation-partout-a-montreal-laval-longueuil-rive-sud-et-rive-nord\"\u003epackaged heat pumps\u003c\/a\u003e page brings together every capacity and brand we offer. AirGreen's RBQ licence number: 5645-9605-01.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e100% free on-site estimate anywhere in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/strong\u003e To plan the installation of this 5 ton heat pump on your roof or on a ground-level stand, call AirGreen at \u003cstrong\u003e514 316-2973\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eDocumentation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/Kinghome_Rooftop_R32_Thermopompe_Monobloc_Brochure_AirGreen_FR.pdf\" target=\"_blank\" rel=\"noopener\"\u003eKinghome Rooftop R32 brochure (French)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/Kinghome_Rooftop_R32_Thermopompe_Monobloc_Brochure_AirGreen_EN.pdf\" target=\"_blank\" rel=\"noopener\"\u003eKinghome Rooftop R32 brochure (English)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Kinghome","offers":[{"title":"Default Title","offer_id":56367196143908,"sku":"KH05TCNHA","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_KINGHOME_ROOFTOP_R32_5_TONNES_00_PROFIL_MONTREAL.png?v=1790077147"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/collections\/THERMOPOMPE_MONOBLOC_KINGHOME_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1790094244","url":"https:\/\/airgreen.ca\/en\/collections\/thermopompe-monobloc-kinghome-montreal-laval-longueuil-rive-sud-et-rive-nord.oembed","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}