{"title":"Packaged Heat Pump System York | Montreal, Laval, Longueuil, South Shore, North Shore","description":"","products":[{"product_id":"thermopompe-monobloc-york-phe4-de-3-tonnes-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York PHE4 of 3 Ton | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eThe Ultimate Guide to the York PHE4 Packaged Heat Pump System of 3 Tons\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAt \u003cstrong data-mce-fragment=\"1\"\u003eAirGreen\u003c\/strong\u003e, we pride ourselves on offering top-tier HVAC services to the communities of Montreal, Laval, Longueuil, North Shore, and South Shore. Our commitment to quality and innovation is evident in our selection of HVAC systems, particularly the packaged heat pump systems. Today, we delve deep into one of our flagship products, the \u003cstrong data-mce-fragment=\"1\"\u003eYork PHE4 Packaged Heat Pump unit\u003c\/strong\u003e. This comprehensive guide will provide you with everything you need to know about this state-of-the-art system.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIntroducing the York PHE4B3634\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe York PHE4, with its model number PHE4B3634, is a SINGLE PACKAGE HEAT PUMP\/ELECTRIC HEAT system. Designed for efficiency and reliability, this unit boasts a 14 SEER rating, ensuring optimal energy consumption. Here are some key specifications:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSEER\u003c\/strong\u003e: 14\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eHSPF\u003c\/strong\u003e: 8\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTonnage\u003c\/strong\u003e: 3 Tons\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSound Level\u003c\/strong\u003e: 73.7 dB\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIndoor Airflow\u003c\/strong\u003e: 1150 CFM\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eRefrigerant\u003c\/strong\u003e: R-410A\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDimensions\u003c\/strong\u003e: 45.75 x 51.25 x 47 inches\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWarranty\u003c\/strong\u003e: 10 years on the compressor, 10 years on parts and 6 years on labor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFeatures That Set the PHE4 Apart\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eOn-Site Flexibility\u003c\/strong\u003e: Its compact design cabinet comes in two footprints, allowing for versatile placement on curbs or pads.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConvertible Airflow Design\u003c\/strong\u003e: This design offers maximum field flexibility with easy transitions from side supply\/return to down supply\/return without additional inventory.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eEfficient Utility Connections\u003c\/strong\u003e: Electric utility access is available through the bottom or side of the unit, ensuring quick connections with minimal field labor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eLower Installation Cost\u003c\/strong\u003e: The unit's design reduces installation time and costs. It's pre-wired, pre-charged with R-410A refrigerant, and tested before shipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eQuality Assurance\u003c\/strong\u003e: The unit undergoes rigorous testing using state-of-the-art computerized systems to ensure top-notch product quality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAdditional Features for Enhanced Performance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCondensate Pan\u003c\/strong\u003e: This corrosion-resistant pan collects and drains all condensate, preventing stagnant water buildup.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDurable Finish\u003c\/strong\u003e: The cabinet is crafted from G90 galvanized steel with a powder paint coating, ensuring durability and resistance against corrosion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFull Perimeter Base Rails\u003c\/strong\u003e: These removable rails provide a solid foundation, ensuring stability during shipment and installation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eProtected Compressor\u003c\/strong\u003e: The compressor has internal protections against high pressure and temperature, ensuring longevity and optimal performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInstallation and Maintenance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe York PHE4 is designed for ease of installation and maintenance. With utility connections made easy, on-site flexibility, and a design that reduces installation costs, it's a hassle-free solution for HVAC needs. Moreover, its design ensures low maintenance, with long-life, permanently lubricated motor bearings that require no annual upkeep.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFrom the Official Brochure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe York PHE4 is not just about specifications; it's about a commitment to quality and performance. The unit is designed for outdoor installation, requiring only utility and duct connections at the installation point. With an operating efficiency rated at 14.0 SEER and 8.0 HSPF, it promises efficient cooling and heating operations. The unit's low operating sound level ensures that your peace is never disturbed, while features like the upward airflow design ensure that the unit's noise is carried away from your living area.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConclusion\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe \u003cstrong data-mce-fragment=\"1\"\u003eYork PHE4 Packaged Heat Pump unit\u003c\/strong\u003e is a testament to AirGreen's commitment to quality and innovation. Designed for efficiency, flexibility, and ease of use, it's the perfect HVAC solution for those in Montreal, Laval, Longueuil, North Shore, and South Shore. Trust in AirGreen to keep your spaces comfortable all year round.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":47474523865380,"sku":"PHE4B3634","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/INSTALLATIONMONTREAL_LAVAL_LONGUEUILSINGLEPACKAGEHEATPUMPELECTRICHEAT14SEER-R-410A-3PHASEPHE4B3634.png?v=1699178907"},{"product_id":"thermopompe-monobloc-york-phe4-de-4-tonnes-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York PHE4 of 4 Ton | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eThe York PHE4 Packaged Heat Pump System of 4 Tons\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAt \u003cstrong data-mce-fragment=\"1\"\u003eAirGreen\u003c\/strong\u003e, we pride ourselves on being the leading HVAC service provider in Montreal, Laval, Longueuil, North Shore, and South Shore. Our commitment to quality and innovation is evident in the products we offer and the services we render. One such product that has garnered attention is the \u003cstrong data-mce-fragment=\"1\"\u003eYork PHE4 Packaged Heat Pump System\u003c\/strong\u003e. This article delves deep into the features, specifications, and benefits of the PHE4, ensuring you make an informed decision for your heating and cooling needs.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eUnveiling the York PHE4\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe York PHE4 is a state-of-the-art \u003cstrong data-mce-fragment=\"1\"\u003eSINGLE PACKAGE HEAT PUMP\/ELECTRIC HEAT\u003c\/strong\u003e system designed for optimal performance and efficiency. With a SEER rating of 14 and an HSPF of 8, this unit promises reliable operation while ensuring energy savings.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eKey Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eBrand:\u003c\/strong\u003e York\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eModel Name:\u003c\/strong\u003e PHE4\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eModel Number:\u003c\/strong\u003e PHE4B4834\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTonnage:\u003c\/strong\u003e 4 Tons\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSEER:\u003c\/strong\u003e 14\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eHSPF:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSound Level:\u003c\/strong\u003e 73.8 dB\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIndoor Airflow:\u003c\/strong\u003e 1500 CFM\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eRefrigerant:\u003c\/strong\u003e R-410A\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDimensions:\u003c\/strong\u003e 45.75 x 51.25 x 53 inches\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWarranty:\u003c\/strong\u003e 10 years (Compressor-Coil-Parts)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDistinguishing Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eUtility Connections Made Simple:\u003c\/strong\u003e The PHE4 offers electric utility access from either the bottom or side of the unit. This design ensures quick connections with minimal field labor. Additionally, a field-supplied and installed electrical disconnect switch is essential.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eOn-Site Flexibility:\u003c\/strong\u003e The compact design cabinet, available in two footprints, provides installers with flexibility in placing the unit on curbs or pads, ensuring optimal space utilization.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConvertible Airflow Design:\u003c\/strong\u003e This feature allows for maximum field adaptability. The bottom duct openings are factory-covered, ready for side supply\/return application. If a bottom supply\/return setup is needed, the panels can be easily switched without any cutting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCondensate Management:\u003c\/strong\u003e The unit comes with a corrosion-resistant condensate pan and a rigidly mounted 3\/4-inch NPT female connection for efficient condensate drainage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDurable Finish:\u003c\/strong\u003e The PHE4 boasts a G90 galvanized steel cabinet with a powder paint coating, ensuring longevity and resistance against corrosion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eEfficient Coil Design:\u003c\/strong\u003e The outdoor coils feature grooved copper tubes and enhanced aluminum fins for improved heat transfer and durability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eLow Maintenance:\u003c\/strong\u003e With long-life, permanently lubricated fan motor bearings and an easily removable blower assembly, the PHE4 promises hassle-free maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAdditional Insights from the Official Brochure\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe PHE4 series is designed for outdoor installation, requiring only utility and duct connections at the installation point. It boasts an operating efficiency with all models rated at 14.0 SEER and 8.0 HSPF. The unit's design ensures reduced installation time and costs, with all units being completely wired, charged with R-410A refrigerant, and tested before shipment.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eFurthermore, the PHE4 series emphasizes easy service access. Individual access panels provide entry to all major components, ensuring effortless maintenance and troubleshooting. The unit's controls are also designed for simplicity, with a printed circuit board containing a status\/diagnostic indicator light and color-coded internal wiring for easy identification.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConclusion\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe \u003cstrong data-mce-fragment=\"1\"\u003eYork PHE4 Packaged Heat Pump System\u003c\/strong\u003e is a testament to AirGreen's commitment to offering top-notch HVAC solutions. Whether you reside in Montreal, Laval, Longueuil, North Shore, or South Shore, our team is ready to assist you in experiencing the unparalleled benefits of the PHE4. With its advanced features, robust build, and efficient performance, it's an investment that promises comfort for years to come.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":47474581635364,"sku":"PHE4B4834","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/INSTALLATIONMONTREAL_LAVAL_LONGUEUILSINGLEPACKAGEHEATPUMPELECTRICHEAT14SEER-R-410A-3PHASEPHE4B4834.png?v=1699178907"},{"product_id":"thermopompe-monobloc-york-phe4-de-5-tonnes-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York PHE4 of 5 Ton | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eThe Ultimate Guide to York's PHE4 Packaged Heat Pump of 5 Tons\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAt \u003cstrong data-mce-fragment=\"1\"\u003eAirGreen\u003c\/strong\u003e, we pride ourselves on being the leading HVAC experts in Montreal, Laval, Longueuil, North Shore, and South Shore. Our commitment to excellence is evident in the quality of services we offer and the products we recommend. One such product that has been making waves in the HVAC industry is the \u003cstrong data-mce-fragment=\"1\"\u003eYork PHE4 Packaged Heat Pump\u003c\/strong\u003e. Let's dive deep into what makes this unit a top choice for homeowners and businesses alike.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIntroducing the York PHE4 Packaged Heat Pump\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe York PHE4 is a state-of-the-art \u003cstrong data-mce-fragment=\"1\"\u003eSINGLE PACKAGE HEAT PUMP\/ELECTRIC HEAT\u003c\/strong\u003e system. Designed for outdoor installation, it ensures only utility and duct connections are required at the point of installation, making the process seamless and efficient.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eKey Specifications:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eBrand:\u003c\/strong\u003e York\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eModel Name:\u003c\/strong\u003e PHE4\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eModel Number:\u003c\/strong\u003e PHE4B6034\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTonnage:\u003c\/strong\u003e 5 Tons\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSEER:\u003c\/strong\u003e 14\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eHSPF:\u003c\/strong\u003e 8\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSound Level:\u003c\/strong\u003e 74.1 dB\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIndoor Airflow:\u003c\/strong\u003e 1850 CFM\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eRefrigerant:\u003c\/strong\u003e R-410A\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDimensions:\u003c\/strong\u003e 45.75 x 51.25 x 55 inches\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDistinctive Features:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003col data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eEfficiency at Its Best:\u003c\/strong\u003e The PHE4 heat pump models boast an impressive 14.0 SEER and 8.0 HSPF, ensuring optimal cooling and heating operations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eOn-Site Flexibility:\u003c\/strong\u003e The compact design cabinet is available in two footprints, providing installers with flexibility in placing the unit on curbs or pads. Moreover, the field convertible duct connections from side shot to down shot offer greater adaptability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCost-Effective Installation:\u003c\/strong\u003e The design reduces installation time and costs. With easy power and control wiring connections and a compact base dimension, it requires minimal space on the ground or roof. Plus, each unit is pre-wired, charged with R-410A refrigerant, and tested before shipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eQuality Assurance:\u003c\/strong\u003e The unit undergoes rigorous testing using a state-of-the-art computerized process system to ensure unparalleled product quality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eUtility Connections Simplified:\u003c\/strong\u003e Electric utility access is provided through the bottom or side of the unit, facilitating quick connections with minimal field labor.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConvertible Airflow Design:\u003c\/strong\u003e This design allows for maximum field flexibility and minimum inventory, ensuring the unit caters to diverse installation requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDurable Finish:\u003c\/strong\u003e The unit's cabinet is crafted from G90 galvanized steel with a powder paint coating, ensuring longevity and resistance against corrosion.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAdditional Features:\u003c\/strong\u003e The PHE4 series comes with a corrosion-resistant condensate pan, a rigidly mounted condensate drain, and an exclusive coil design that enhances heat transfer efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAdditional Insights from the Official Brochure:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe PHE4 series is designed with the user in mind. It offers \u003cstrong data-mce-fragment=\"1\"\u003eeasy service access\u003c\/strong\u003e, with individual panels that provide access to all major components. This ensures that servicing is hassle-free and efficient. Moreover, the unit is compatible with standard, 24-V electronic non-power stealing and electromechanical thermostats, offering flexibility in operation.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWhy Choose the York PHE4 Packaged Heat Pump?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe York PHE4 is not just another packaged heat pump; it's a testament to York's commitment to quality, efficiency, and user-centric design. Whether you're a homeowner looking for a reliable heating solution or a business owner aiming to provide a comfortable environment for your employees, the PHE4 is the answer.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAt \u003cstrong data-mce-fragment=\"1\"\u003eAirGreen\u003c\/strong\u003e, we understand the importance of a dependable HVAC system. That's why we recommend the York PHE4 to our esteemed clients in Montreal, Laval, Longueuil, and beyond. With its impressive features, durable design, and the backing of a trusted brand like York, you can't go wrong with the PHE4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":47474615386404,"sku":"PHE4B6034","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/INSTALLATIONMONTREAL_LAVAL_LONGUEUILSINGLEPACKAGEHEATPUMPELECTRICHEAT14SEER-R-410A-3PHASEPHE4B6034.png?v=1699178907"},{"product_id":"thermopompe-monobloc-york-ph3-de-2-tonnes-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York PH3 2 Ton | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eSmall spaces: a 2 ton packaged heat pump sized as closely as possible\u003c\/h2\u003e\n\u003cp\u003eA condo with a rooftop terrace, a small townhouse or a recent addition does not need an oversized unit. It needs a \u003cstrong\u003eproperly sized\u003c\/strong\u003e unit, one that cools without chilling the room all at once and then shutting off, and that heats efficiently through the shoulder seasons. The 2 ton YORK PH3 heat pump meets that need with a rated capacity of 24,000 BTU\/h and the narrowest cabinet in the whole PH3 series: 35.75 in. wide. At AirGreen, we install it on the roof as well as at ground level, in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\u003ch3\u003eThe whole system in a single outdoor cabinet\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e brings together in one outdoor cabinet the compressor, the outdoor coil, the indoor coil and the blower that pushes the air into your ducts. Indoors, all that is left is the thermostat and the duct system: no furnace and no fan coil to fit into a closet. In a condo where every square foot counts, that is often the deciding argument. The unit sits on a roof curb or on a pad, and only the electrical connections and the supply and return ducts are done on site. YORK ships every unit fully wired, charged with R-454B refrigerant and factory tested before shipping.\u003c\/p\u003e\n\u003ch3\u003eWhy a 2 ton rather than a bigger unit\u003c\/h3\u003e\n\u003cp\u003eThe instinct to \"go bigger, just in case\" works against comfort. The PH3 uses a \u003cstrong\u003escroll compressor\u003c\/strong\u003e with a single stage: when it starts, it runs at full capacity. If that capacity clearly exceeds what the home needs, the thermostat setpoint is reached within a few minutes, the unit shuts off, then starts again shortly after. These short cycles multiply compressor starts and, above all, leave the moisture in the air.\u003c\/p\u003e\n\u003cp\u003eIn summer, \u003cstrong\u003edehumidification\u003c\/strong\u003e takes place on the indoor coil: the warm, humid air cools there, the water vapour condenses and the water drains into the condensate pan, a watertight, corrosion-resistant pan that meets ASHRAE 62 for indoor air quality. That work takes continuous run time. A unit matched to the real load runs longer on each cycle, pulls out more moisture and delivers the cool, dry air you appreciate during a heat wave. The performance tables in the YORK guide in fact separate total capacity from sensible capacity: the gap between the two is the moisture removed from the air.\u003c\/p\u003e\n\u003cp\u003eThat is why we never pick a capacity by eye. The YORK technical guide follows the same logic: you first determine the building's load, then you install the unit of the right capacity in the smallest possible footprint. We run that calculation during the estimate, taking into account the windows, the insulation, the orientation and how the rooms are occupied. The indoor blower speeds, set at the factory for cooling and for heating, can also be adjusted on site to fine-tune the balance between airflow and comfort.\u003c\/p\u003e\n\u003ch3\u003eSpec sheet for the 2 ton PH3\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel number: PH3E24N00S21 (YORK LX series)\u003c\/li\u003e\n\u003cli\u003eRated capacity: 24,000 BTU\/h (2 ton)\u003c\/li\u003e\n\u003cli\u003eNet cooling (AHRI): 23,800 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 22,200 BTU\/h, with a COP of 3.8\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 13,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eEfficiency: 13.4 SEER2, 6.7 HSPF2 and 11.1 EER2\u003c\/li\u003e\n\u003cli\u003eRated airflow: 880 CFM (cubic feet per minute)\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V single-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B, an A2L refrigerant with a low global warming potential\u003c\/li\u003e\n\u003cli\u003eDimensions (width x depth x height): 35.75 x 51.25 x 44 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 340 lb\u003c\/li\u003e\n\u003cli\u003eSound level (AHRI 270): 70.3 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eA narrow cabinet for roof terraces and tight yards\u003c\/h3\u003e\n\u003cp\u003eAt 35.75 in. wide, the 2 ton model uses the smaller of the two footprints in the series, while the 3 to 5 ton models move up to 45.75 in. Its height of 44 in. and its 340 lb operating weight make it the easiest unit to place on a roof terrace or along a narrow back yard. The \u003cstrong\u003ebase rails\u003c\/strong\u003e that run around the whole unit have lifting holes for a crane and let forklift forks in from all four sides. Where height is limited, they come off by removing two screws at each corner.\u003c\/p\u003e\n\u003cp\u003eOn a wood terrace or a roof covered with a class A, B or C covering, the YORK guide allows installation directly on those combustible materials, provided the factory base rails are left in place. We always check the structure before setting the unit down on it.\u003c\/p\u003e\n\u003ch4\u003eClearances to allow around the unit\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e36 in. above, for the vertical discharge of the outdoor fan;\u003c\/li\u003e\n\u003cli\u003e36 in. on the right side and on the side opposite the ducts;\u003c\/li\u003e\n\u003cli\u003e24 in. on the left side and 6 in. on the duct panel side.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003evertical discharge\u003c\/strong\u003e works in your favour on a terrace: the outdoor fan blows the air upward, so the warm air and the running noise move away from the living space and the neighbours, and the potted plants around the unit do not dry out.\u003c\/p\u003e\n\u003ch3\u003eRugged components in a smaller format\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor coil with rifled copper tubes and enhanced aluminum fins, protected by a louvred stamped metal grille;\u003c\/li\u003e\n\u003cli\u003eall-aluminum indoor coil, three rows deep, fed by factory-mounted thermostatic expansion valves (TXV);\u003c\/li\u003e\n\u003cli\u003edirect-drive indoor blower with a 1\/2 HP ECM motor, mounted on a slide-out assembly that pulls out easily for cleaning;\u003c\/li\u003e\n\u003cli\u003eG90 galvanized steel cabinet finished with a powder paint tested for 1,000 hours in salt spray;\u003c\/li\u003e\n\u003cli\u003efactory-installed refrigerant detection system (RDS) and a demand defrost board with preloaded defrost curves;\u003c\/li\u003e\n\u003cli\u003ehigh-pressure switch, loss-of-charge switch and a compressor internally protected against high pressure and high temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBackup heat matched to the home\u003c\/h3\u003e\n\u003cp\u003eFor the coldest days, the PH3 accepts a 6HK \u003cstrong\u003eelectric heat kit\u003c\/strong\u003e installed on site. For the 2 ton model, the YORK guide lists kits of 5, 8 and 10 kW, which deliver 4.4 kW, 7.1 kW and 8.8 kW respectively at 230 V. A single-point wiring kit lets one circuit feed both the unit and the kit. Here too, we choose the kit from the heat loss calculation, without oversizing.\u003c\/p\u003e\n\u003ch2\u003eYour condo or your addition in AirGreen's hands\u003c\/h2\u003e\n\u003cp\u003eAirGreen inc. is a Montreal HVAC contractor that sells and installs. A single contact handles your project, from the first visit through to commissioning, with the speed and efficiency an occupied site demands.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree on-site estimate:\u003c\/strong\u003e we measure the available space, check access to the roof or the yard and assess your ducts;\u003c\/li\u003e\n\u003cli\u003ea load calculation to confirm that 2 tons really matches your needs, or to point you to another size;\u003c\/li\u003e\n\u003cli\u003einstallation by our crews: roof curb or pad, lifting, connection to the ducts and to the electrical supply, thermostat setup;\u003c\/li\u003e\n\u003cli\u003eperiodic maintenance to keep the filters, the coils and the condensate drain in good shape.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOur territory covers Montreal, Laval, Longueuil, the North Shore and the South Shore. Call us at 514 316-2973 or write to us through the form on airgreen.ca: we will set a time with you for the free on-site estimate, then give you a detailed quote for a packaged heat pump cut to the measure of your small space.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367079850276,"sku":"PH3E24N00S21","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_PH3_00_PRINCIPALE_b8f5ea20-df9f-43fd-991f-19730daa06db.png?v=1790963873"},{"product_id":"thermopompe-monobloc-york-ph3-de-3-tonnes-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York PH3 3 Ton | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eReplacing an old packaged unit without redoing your ducts\u003c\/h2\u003e\n\u003cp\u003eIn many bungalows and single-storey houses, cooling and heating have relied for years on a packaged unit sitting on a pad along the wall or installed on the roof. When that unit reaches the end of its life, the simplest solution is often to replace it with a unit of the same type. The 3 ton YORK PH3 heat pump, with a nominal capacity of 36,000 BTU\/h, lends itself very well to a \u003cstrong\u003ereplacement\u003c\/strong\u003e of this kind: it works on the all-in-one principle you already know, connects to your existing ducts and adapts to the configuration in place. Our crews carry out these replacements throughout the region, from Montreal to Laval and Longueuil, out to the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eThe same all-in-one principle, with up-to-date components\u003c\/h3\u003e\n\u003cp\u003eIf you already have a packaged unit, you know the principle: the compressor, the two coils and the blower are housed in a single outdoor cabinet, and the house receives only conditioned air, through the supply and return ducts. Nothing changes on that side. What changes is what sits inside the cabinet: a new-generation R-454B refrigerant, a high-efficiency ECM motor for the \u003cstrong\u003eindoor blower\u003c\/strong\u003e, a factory-mounted refrigerant detection system (RDS) and a demand defrost board whose defrost curves are preloaded according to the unit's capacities. The PH3 is a \u003cstrong\u003eheat pump\u003c\/strong\u003e, which means the same circuit provides cooling in summer and heating through the cold season, thanks to its reversing valve.\u003c\/p\u003e\n\u003ch3\u003eThe data for the 3 ton single-phase PH3\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePH3E36N00S21, YORK LX series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h (3 tons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet cooling (AHRI)\u003c\/td\u003e\n\u003ctd\u003e35,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating capacity at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e34,000 BTU\/h, COP of 3.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating capacity at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e21,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency ratings\u003c\/td\u003e\n\u003ctd\u003e13.4 SEER2, 6.7 HSPF2, 11.1 EER2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e1,200 CFM (cubic feet per minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e208\/230 V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (width x depth x height)\u003c\/td\u003e\n\u003ctd\u003e45.75 x 51.25 x 47 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e423 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e72.9 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L, low global warming potential)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSide or bottom connection, with no cutting\u003c\/h3\u003e\n\u003cp\u003eThe trickiest point in a replacement is where the ducts come in. In some houses, the ducts come in from the side, through the foundation wall; in others, from underneath, through a roof curb. The PH3 takes both, thanks to its \u003cstrong\u003econvertible airflow\u003c\/strong\u003e design. It leaves the factory with the bottom openings closed off, ready for side supply and return. To move to a bottom configuration, the two bottom panels are removed and put back in the side openings. No panel to cut, no extra part to order.\u003c\/p\u003e\n\u003cp\u003eOn the side, the supply and return connections are the same size, which makes it possible to reach the ducts of a low crawl space without transition pieces. If your existing ducts are round, YORK offers preformed rectangular-to-round adapters: 12 or 14 in. for horizontal connections, 16 or 18 in. for vertical connections in the roof curb.\u003c\/p\u003e\n\u003ch3\u003eReusing the existing pad or roof curb\u003c\/h3\u003e\n\u003cp\u003eOn the ground, the unit rests on its perimeter \u003cstrong\u003ebase rails\u003c\/strong\u003e, which keep it above the pad to limit corrosion. A closure kit for the rail openings keeps small animals from nesting in them, and an anchoring kit certified for wind load holds the unit firmly to its pad. At 45.75 in. wide and 51.25 in. deep, its footprint is compact; we check on site whether the existing pad can be reused.\u003c\/p\u003e\n\u003cp\u003eOn the roof, you have two options. YORK offers NRCA-approved roof curbs 8 or 14 in. high, hinged at each corner and shipped with a sealing strip. If a curb is already there, transition kits make it possible to keep it by adapting the unit's footprint to YORK Affinity curbs or to Carrier, Trane and Goodman curbs. The vertical supply and return openings are designed to fit between standard joists spaced 24 in. o.c., without altering the structure.\u003c\/p\u003e\n\u003ch3\u003eA cabinet built to stay outside for a long time\u003c\/h3\u003e\n\u003cp\u003eOld packaged units often end up rusted at the corners and at the bottom of the panels. The PH3 is built from pretreated G90 galvanized steel, coated with a \u003cstrong\u003epowder paint\u003c\/strong\u003e tested 1,000 hours in salt spray, which bonds better to the steel and resists the spread of rust. The one-piece top cover, with seamless corners and drip edges, seals better against water, while the outdoor coil grille, in slotted stamped metal, protects the fins from small objects.\u003c\/p\u003e\n\u003ch3\u003eWhat we check before removing the old unit\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe electrical supply.\u003c\/strong\u003e Without backup heat, the 3 ton PH3 calls for a minimum circuit ampacity (MCA) of 27.3 A and a maximum overcurrent protection (MOP) of 40 A, through an HACR-type breaker or a time-delay fuse. A field-supplied electrical disconnect must also be installed, and the supply voltage must sit between 187 and 252 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe ducts.\u003c\/strong\u003e We inspect the system and assess its resistance: YORK does not recommend applications above 0.8 in. of water column of external static pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe support.\u003c\/strong\u003e A cracked or settled pad, a roof curb in poor condition: we report every defect and correct it before the unit goes in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrainage.\u003c\/strong\u003e The 3\/4 in. female NPT condensate connection, rigidly fixed, must reach a proper drain point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe thermostat.\u003c\/strong\u003e The PH3 works with a conventional 24 V thermostat, electronic or electromechanical.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eElectric backup heat\u003c\/h3\u003e\n\u003cp\u003eIf your old unit had electric heat strips, the PH3 takes a field-installed 6HK kit. Four sizes are available for the 3 ton: 5, 8, 10 and 15 kW. The largest runs in two stages and delivers 13.2 kW at 230 V. With the single-point wiring kit offered as an accessory, the unit and its heat strips share a single supply.\u003c\/p\u003e\n\u003ch2\u003eA turnkey replacement with AirGreen\u003c\/h2\u003e\n\u003cp\u003eA successful replacement is won in the preparation. During the \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, we take down the dimensions of the old unit, the position of the connections, the condition of the pad or the roof curb and the capacity of your electrical service. We then confirm by calculation that 3 tons suits your house. On installation day, our crews remove the old unit, convert the PH3 openings if needed, connect it to the ducts and to the power, then carry out the full start-up. We then stay available for seasonal maintenance.\u003c\/p\u003e\n\u003cp\u003eYou live in Montreal, Laval, Longueuil, on the North Shore or on the South Shore and your packaged unit is showing its age: call 514 316-2973 or use the form on airgreen.ca to book the visit. We work quickly and efficiently to limit the time your house goes without cooling or heating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367080112420,"sku":"PH3E36N00S21","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_PH3_00_PRINCIPALE_6c446f06-8a7e-42fd-bfa0-2ef519b16ee2.png?v=1790963855"},{"product_id":"thermopompe-monobloc-york-ph3-de-3-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York PH3 3 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eA business supplied in three-phase, a cabinet of residential size\u003c\/h2\u003e\n\u003cp\u003eNeighbourhood shop, professional practice, salon or service space: many small businesses occupy buildings supplied with \u003cstrong\u003e208\/230 V three-phase\u003c\/strong\u003e power. For these spaces, the 3 ton YORK PH3 heat pump comes in a three-phase version. You get the cooling and the heating of a 36,000 BTU\/h unit, housed in the same compact cabinet as the residential single-phase version and connected directly to the electrical supply of your building. AirGreen designs and installs these systems for the business owners and the building owners of Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eA complete unit, installed outside your sales floor\u003c\/h3\u003e\n\u003cp\u003eIn a business, indoor space earns its keep: it is there to display, to welcome customers or to work in. The \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e frees up that space, since all the refrigeration components and the distribution blower sit in a single outdoor cabinet, usually on the roof. The cooled or heated air comes down into the space through the supply ducts and returns to the unit through the return. No mechanical equipment takes up the back room, and the technicians do the maintenance outdoors, without disturbing your business.\u003c\/p\u003e\n\u003ch3\u003eWhat three-phase power changes\u003c\/h3\u003e\n\u003cp\u003eThree-phase spreads the load over three conductors. The YORK electrical data show it clearly: with no heat kit, the three-phase model calls for a circuit with a minimum circuit ampacity (MCA) of 21.8 A, with a maximum overcurrent protection (MOP) of 30 A. The single-phase version of the same 3 ton unit requires 27.3 A and 40 A. The protection has to be provided by an HACR type breaker or a time-delay fuse, and a field-supplied disconnect is mandatory. The applied voltage has to stay between 187 and 252 V.\u003c\/p\u003e\n\u003cp\u003eThe backup heat follows the same logic. In three-phase, the \u003cstrong\u003e6HK\u003c\/strong\u003e kits offered for this model are 10 and 15 kW, that is 8.8 and 13.2 kW actual at 230 V, or 7.2 and 10.8 kW at 208 V. Single-point wiring kits (S1-2SPWK031 for 10 kW, S1-2SPWK033 for 15 kW) bring together the terminal block, the fuse holders and the wiring to feed the unit and its heating elements from a single source.\u003c\/p\u003e\n\u003ch3\u003eSizing for a commercial space\u003c\/h3\u003e\n\u003cp\u003eA business is not calculated like a house. Display lighting, computers, work equipment, a storefront window in full sun and customers coming and going all add heat throughout the day. Our \u003cstrong\u003eload calculation\u003c\/strong\u003e takes these gains into account to confirm that 3 tons is enough. If the result points to a larger need, the three-phase 4 and 5 ton versions of the PH3 take up the same floor footprint of 45.75 x 51.25 in.; only the height of the unit increases.\u003c\/p\u003e\n\u003ch3\u003eSpecifications of the three-phase 3 ton PH3\u003c\/h3\u003e\n\u003ch4\u003ePerformance rated to the AHRI methods\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNet cooling: 35,400 BTU\/h (3 ton nominal model)\u003c\/li\u003e\n\u003cli\u003eIn heating at 47 °F (8.3 °C): 34,000 BTU\/h and a COP of 3.6\u003c\/li\u003e\n\u003cli\u003eIn heating at 17 °F (-8.3 °C): 21,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eRatings: 13.4 SEER2 in cooling, 6.7 HSPF2 in heating, 11.1 EER2\u003c\/li\u003e\n\u003cli\u003eIndoor blower airflow: 1,200 CFM nominal (ft³\/min)\u003c\/li\u003e\n\u003cli\u003eSound level to the AHRI 270 standard: 72.0 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInstallation data\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eModel: PH3E36N00S31 (YORK LX series)\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B, a class A2L refrigerant whose global warming potential is low, with a factory-mounted refrigerant detection system (RDS)\u003c\/li\u003e\n\u003cli\u003eOverall size: 45.75 in. wide, 51.25 in. deep and 47 in. high\u003c\/li\u003e\n\u003cli\u003eWeight once in service: 423 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe coefficient of performance (COP) measures efficiency in heating: at 47 °F, the 3 ton PH3 delivers 3.6 units of heat for every unit of electricity it consumes. The YORK performance tables show that this efficiency is better in mild weather, which makes the heat pump a sound choice for the fall and the spring.\u003c\/p\u003e\n\u003ch3\u003eA discreet installation on the roof\u003c\/h3\u003e\n\u003cp\u003eAt 47 in. high, with its rounded corners and its one-piece top cover, the PH3 has a low profile and a clean look that fit easily on a commercial roof. Its outdoor fan discharges vertically: the exhaust air and the operating noise go up rather than toward the terrace next door or the windows on the floor above. The compressor is mounted on isolators, the rigid top panel dampens the noise and the formed base of the cabinet also contributes to the sound insulation.\u003c\/p\u003e\n\u003cp\u003eOn the roofing side, two heights of NRCA-approved YORK \u003cstrong\u003eroof curbs\u003c\/strong\u003e are offered, 8 in. and 14 in., with a gasket, along with a roof anchor kit certified for wind load. The bottom openings fit between standard joists at 24 in. o.c.: neither the framing nor the ducts have to be modified. The base rails include lifting holes for the crane, and the guide allows installation on a class A, B or C combustible roof covering when these factory rails stay in place.\u003c\/p\u003e\n\u003ch3\u003eFresh air for customers and staff\u003c\/h3\u003e\n\u003cp\u003eA space that welcomes the public needs fresh air. The PH3 can take a manual outdoor air damper, adjustable from 0 to 50%, or a motorized damper with the same range that closes in the event of a power failure; both include a hood and a screen. For more demanding needs, modulating integrated economizers are offered for vertical or horizontal configurations.\u003c\/p\u003e\n\u003ch4\u003eFilters supplied with the unit\u003c\/h4\u003e\n\u003cp\u003eAll the three-phase PH3 models ship with a filter rack kit and 1 in. filters, stored inside the unit when it leaves the factory. We install them at commissioning; they then stay accessible through a removable, sealed door, which makes replacing them during maintenance simple.\u003c\/p\u003e\n\u003ch3\u003eA simple thermostat for the whole team\u003c\/h3\u003e\n\u003cp\u003eOn the control side, a simple 24 V wall thermostat is enough, electronic or electromechanical. The unit accepts a single-stage model in heating and in cooling, with or without an economizer: your employees have only one setpoint to adjust. YORK also offers compatible thermostats in its accessory line. Inside the cabinet, an indicator light on the control board shows the status of the unit and helps the technician find the cause of a shutdown quickly, which shortens service calls.\u003c\/p\u003e\n\u003ch2\u003eAirGreen, your HVAC partner for commercial spaces\u003c\/h2\u003e\n\u003cp\u003eA commercial project takes coordination: roof access, opening hours, the requirements of the building owner. The first step is a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, during which we assess the thermal load of the space, the condition of the ducts, the three-phase supply available and the location on the roof. Our crews then take care of the complete installation, from the lift to the electrical hookup, and then the commissioning. We plan the work so as to limit the impact on your business hours, and we can take over the maintenance of the unit afterwards.\u003c\/p\u003e\n\u003cp\u003eWhether your business is in Montreal, Laval or Longueuil, or on the North Shore or the South Shore, call AirGreen at 514 316-2973 or request your free on-site estimate through the form on airgreen.ca. An advisor will call you back promptly to set up the visit to your space.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367080145188,"sku":"PH3E36N00S31","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_PH3_00_PRINCIPALE_51e118de-7656-47f3-9150-a0ed98e8fd55.png?v=1790963838"},{"product_id":"thermopompe-monobloc-york-ph3-de-4-tonnes-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York PH3 4 Ton | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eFrom the ground floor to the upstairs: airflow that reaches everywhere\u003c\/h2\u003e\n\u003cp\u003eIn a two-storey house or a cottage, comfort is not measured at the thermostat alone. It is measured in the upstairs bedroom in July, in the living room in January and in every room in between. The 4 ton YORK PH3 heat pump, with a nominal capacity of 48,000 BTU\/h, suits this type of home well: its indoor blower, rated at 1,710 CFM, distributes the air through the existing duct system so that cooling and heating reach every level. AirGreen installs it on a pad or on a roof curb in the residential neighbourhoods of Montreal, Laval and Longueuil, as well as on the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eThe challenge of a two-storey home\u003c\/h3\u003e\n\u003cp\u003eWarm air rises, cool air falls. In summer, the upper floor warms up faster than the ground floor; in winter, it is often the basement or the lower rooms that stay cool. With a \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e, a single outdoor unit conditions the air and pushes it through the whole system: the compressor, the coils and the supply blower share the same cabinet, connected to the house by a supply duct and a return duct. The result on each floor therefore comes down to two things: enough \u003cstrong\u003eairflow\u003c\/strong\u003e and a well-balanced duct system.\u003c\/p\u003e\n\u003ch3\u003e1,710 CFM and an ECM blower that can be adjusted\u003c\/h3\u003e\n\u003cp\u003eThe indoor blower of the 4 ton PH3 is a double-inlet centrifugal wheel with forward-curved blades, driven directly by a high-efficiency 3\/4 HP \u003cstrong\u003eECM\u003c\/strong\u003e motor. The wheel is dynamically balanced to run smoothly over its entire operating range, and its sealed bearings are lubricated for life. Cooling and heating speeds are set at the factory, but we can adjust them on site to obtain the airflow that suits your ducts.\u003c\/p\u003e\n\u003cp\u003eAn existing duct system has its limits. YORK advises against any application where external static pressure exceeds 0.8 in. w.c. (water column). Before the installation, we therefore measure the resistance of your ducts and check for return air openings upstairs. Where needed, we add balancing dampers on the main branches to send a larger share of the air to the rooms that are short of it.\u003c\/p\u003e\n\u003ch4\u003eFilters sized for the airflow\u003c\/h4\u003e\n\u003cp\u003eA filter that is too small slows the air down before it even reaches the upper floor. On single-phase models, filters are supplied and installed on site: either in the return, in which case YORK requires them to be sized so the air velocity through a disposable filter does not exceed 300 ft\/min, or in the unit, with the filter rack kit offered as an accessory, which accepts 1 or 2 in. filters. We choose the solution that best protects your airflow.\u003c\/p\u003e\n\u003ch3\u003eThe numbers of the 4 ton PH3\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel PH3E48N00S21, YORK LX series, R-454B refrigerant\u003c\/li\u003e\n\u003cli\u003eNominal capacity of 48,000 BTU\/h and AHRI net cooling of 48,500 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating of 47,000 BTU\/h at 47 °F (8.3 °C), with a COP of 3.7\u003c\/li\u003e\n\u003cli\u003eHeating of 28,500 BTU\/h at 17 °F (-8.3 °C)\u003c\/li\u003e\n\u003cli\u003eSeasonal efficiency of 13.4 SEER2 in cooling and 6.7 HSPF2 in heating, EER2 of 11.1\u003c\/li\u003e\n\u003cli\u003eNominal blower airflow: 1,710 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003e208\/230 V single-phase power supply, 60 Hz\u003c\/li\u003e\n\u003cli\u003eCabinet of 45.75 x 51.25 x 50 in. (width x depth x height)\u003c\/li\u003e\n\u003cli\u003eOperating weight of 482 lb and AHRI 270 sound level of 71.6 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTo exchange that much heat, the 4 ton model has a four-row all-aluminum indoor coil and a two-row outdoor coil made of rifled copper tubes and enhanced aluminum fins. Factory-installed thermostatic expansion valves meter the refrigerant, and a 26 in. outdoor fan with vertical discharge moves the air across the outdoor coil.\u003c\/p\u003e\n\u003ch3\u003eGround pad or roof curb: how to choose\u003c\/h3\u003e\n\u003cp\u003eThe PH3 connects from the side or from the bottom. It leaves the factory ready for side connections; for a bottom configuration, you simply move the two bottom panels over to the side openings, with no cutting. According to the YORK guide, the airflow difference between the two configurations is negligible: the choice is therefore made according to your house.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCriterion\u003c\/th\u003e\n\u003cth\u003eOn a ground pad\u003c\/th\u003e\n\u003cth\u003eOn a roof curb\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eFrom the side, through the foundation wall, to a duct system in the basement or in the crawl space\u003c\/td\u003e\n\u003ctd\u003eFrom the bottom, through a flat roof section, to a duct system upstairs or in the attic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting in place\u003c\/td\u003e\n\u003ctd\u003eHandling at ground level; the base rails are reachable by forklift from every side\u003c\/td\u003e\n\u003ctd\u003eCrane lift thanks to the holes provided in the base rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUseful accessories\u003c\/td\u003e\n\u003ctd\u003eAnchoring kit certified for wind resistance, kit that closes off the rail openings against small animals\u003c\/td\u003e\n\u003ctd\u003eNRCA-approved roof curb of 8 or 14 in., with sealing strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd\u003e36 in. on top, on the right and on the side opposite the ducts; 24 in. on the left\u003c\/td\u003e\n\u003ctd\u003eSame clearances, and openings designed to fit between standard joists spaced 24 in. on centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAt ground level, we place the unit away from bedroom windows and clear of the water dripping off the roof. The \u003cstrong\u003evertical discharge\u003c\/strong\u003e sends the warm air upward, away from your flower beds and shrubs, provided that no overhanging structure or branch blocks the air outlet.\u003c\/p\u003e\n\u003ch3\u003eBackup heat up to 20 kW\u003c\/h3\u003e\n\u003cp\u003eIn a two-storey house, electric backup heat deserves a precise calculation. For the 4 ton unit, the YORK guide lists 6HK kits of 5, 8, 10, 15 and 20 kW. The 20 kW kit runs in two stages and delivers 17.6 kW at 230 V, or 14.4 kW at 208 V. It requires 1 in. of clearance around the supply duct over the first three feet. Without a kit, the unit calls for a minimum circuit ampacity of 36.5 A and maximum overcurrent protection of 50 A; power for the unit and its kit can then be brought together at a single point with the S1-2SPWK004 wiring kit.\u003c\/p\u003e\n\u003ch2\u003eTrust our teams with the comfort of the whole family\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a Montreal HVAC contractor that sells and installs its own systems. For a two-storey house, our \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e visit covers the ducts as much as the unit: we examine the air path, the returns, the dampers and the possible location on a pad or on the roof. We calculate the load of each level, confirm that 4 tons meet your needs, then our teams carry out the installation, the balancing of the duct system and the start-up. Periodic maintenance follows, to keep filters, coils and the condensate drain in good condition.\u003c\/p\u003e\n\u003cp\u003eFrom Montreal to Laval, from Longueuil to the South Shore and out to the municipalities of the North Shore, we travel quickly to assess your home. Reach us at 514 316-2973 or through the form on airgreen.ca to book your free on-site estimate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367080538404,"sku":"PH3E48N00S21","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_PH3_00_PRINCIPALE_194b9180-dece-4886-ab52-6faaa06e8258.png?v=1790963820"},{"product_id":"thermopompe-monobloc-york-ph3-de-4-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York PH3 4 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eCommon areas and small offices: a reliable heat pump, simple to maintain\u003c\/h2\u003e\n\u003cp\u003eEntrance hall, corridors, community room, ground floor offices in a mixed-use building: the common areas of a plex or a small building have to stay comfortable without becoming a headache for the owner or the manager. The 4 ton YORK PH3 heat pump in the \u003cstrong\u003e208\/230 V three-phase\u003c\/strong\u003e version suits this kind of assignment particularly well: 48,000 BTU\/h of nominal capacity, proven construction, easy service access and straightforward control. We install it for owners, condo boards and building managers across the greater region: Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eWhy a packaged unit in a building\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e concentrates the whole refrigeration system and the supply fan in a single cabinet, set on the roof or at ground level. The ducts carry the conditioned air into the common areas, then bring it back to the unit. No mechanical room to build, no indoor unit to fit into a corridor closet, and above all no need to enter the apartments for maintenance: the technician works outside, at the time that suits the building.\u003c\/p\u003e\n\u003ch3\u003eReliability starts at the factory\u003c\/h3\u003e\n\u003cp\u003eThe PH3 units are assembled in a plant whose quality management system is ISO 9001:2015 certified. Every unit is fully wired, charged with R-454B refrigerant and tested before shipping on computerized test stations. The refrigerant charge and the component numbers are verified by barcode scanning during assembly, and the run test data, such as the system pressures and the motor currents, is recorded. On request, this data can be retrieved from the serial number, an advantage for anyone who keeps a maintenance log. The unit is CSA certified to the UL 60335-2-40 and CAN\/CSA-C22.2 No 60335-2-40:22 standards.\u003c\/p\u003e\n\u003ch4\u003eThe standard protections\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHermetic scroll compressor whose internal protection combines a high pressure relief valve and a temperature sensor, which shut it down if operating conditions become inadequate;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ehigh pressure switch\u003c\/strong\u003e that locks the unit out under abnormal conditions, until it is reset;\u003c\/li\u003e\n\u003cli\u003eloss of refrigerant pressure switch, supplied with the unit, for a safe compressor shutdown;\u003c\/li\u003e\n\u003cli\u003etotally enclosed outdoor fan motor, internally protected against overloads;\u003c\/li\u003e\n\u003cli\u003efilter drier or strainer to catch the impurities in the refrigeration circuit, and refrigerant detection (RDS) built in at the factory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eService access designed for technicians\u003c\/h3\u003e\n\u003cp\u003eEvery major component has its own \u003cstrong\u003eaccess panel:\u003c\/strong\u003e compressor, indoor coil, fan, controls, electric heat kit and filters. The electrical box is not housed in the compressor compartment, and the controls are mounted so that their panel can be removed for diagnostics without disturbing the normal system pressures. The fan assembly and the indoor coil assembly slide out of the cabinet for cleaning. According to YORK, no special training is required to replace a component, and the number of unique parts has been reduced, which makes sourcing easier.\u003c\/p\u003e\n\u003ch3\u003eThe data for the 4 ton three-phase PH3\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eData\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003cth\u003eWhat it means\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePH3E48N00S31\u003c\/td\u003e\n\u003ctd\u003eYORK LX series, three-phase version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet cooling (AHRI)\u003c\/td\u003e\n\u003ctd\u003e48,500 BTU\/h\u003c\/td\u003e\n\u003ctd\u003eNet cooling capacity, fan heat deducted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e47,000 BTU\/h, COP of 3.7\u003c\/td\u003e\n\u003ctd\u003eHeating performance in mild weather\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e28,600 BTU\/h\u003c\/td\u003e\n\u003ctd\u003eCapacity kept in cold weather, before the electric backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eSEER2 of 13.4, HSPF2 of 6.7 and EER2 of 11.1\u003c\/td\u003e\n\u003ctd\u003eRatings established under the requirements of the United States Department of Energy (DOE) and the AHRI methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e1,700 CFM (ft³\/min)\u003c\/td\u003e\n\u003ctd\u003eVolume of air delivered to the areas served\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e208\/230 V three-phase, 60 Hz\u003c\/td\u003e\n\u003ctd\u003eDirect connection to the building's three-phase service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e45.75 in. x 51.25 in. x 50 in.\u003c\/td\u003e\n\u003ctd\u003eWidth, depth and height of the cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e482 lb\u003c\/td\u003e\n\u003ctd\u003eUseful figure for checking the roof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e72.0 dBA\u003c\/td\u003e\n\u003ctd\u003eStandardized sound rating of the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eStraightforward control\u003c\/h3\u003e\n\u003cp\u003eNo complex programming to pass on to the caretaker: the PH3 is driven by a 24 V \u003cstrong\u003estandard thermostat\u003c\/strong\u003e, either an electronic model that does not draw its power from the control circuit, or an electromechanical model, single stage in heating as in cooling. The thermostat wires land on the screw terminals of the refrigerant detection system. Inside, the cooling controls rely on a contactor and relays, the connectors are the MATE-N-LOK type, and all the internal wiring is colour coded and numbered. A status and diagnostic indicator light on the board, along with a demand defrost control with preloaded curves, round out the package.\u003c\/p\u003e\n\u003ch3\u003ePower supply and backup heat in three-phase\u003c\/h3\u003e\n\u003cp\u003eWithout a heat kit, the 4 ton three-phase PH3 calls for a circuit with a minimum circuit ampacity of 24.5 A, protected at 35 A maximum by an HACR breaker or a time-delay fuse, plus a field-supplied disconnect switch. Three three-phase 6HK kits are planned for this model, of 10, 15 and 20 kW. The last one heats in two stages, delivers 17.6 kW at 230 V and includes its own breakers. Single point wiring kits (S1-2SPWK032, S1-2SPWK034 or S1-2SPWK035, depending on the kit chosen) allow a single power supply.\u003c\/p\u003e\n\u003ch3\u003eWhat we check at every maintenance visit\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eReplacement of the 1 in. filters, housed in the filter rack supplied with the three-phase models;\u003c\/li\u003e\n\u003cli\u003einspection and cleaning of the indoor coil and the blower wheel, pulled out of their housing if needed;\u003c\/li\u003e\n\u003cli\u003ecleaning of the outdoor coil and check of its protective grille;\u003c\/li\u003e\n\u003cli\u003echeck of the condensate pan and drain, whose 3\/4 in. NPT connection is rigidly fixed;\u003c\/li\u003e\n\u003cli\u003echeck of the electrical connections, the pressures and the operation in heating as in cooling.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe bearings on the indoor fan motor and the outdoor fan motor are lubricated for life: they call for no annual lubrication, which shortens the task list by that much.\u003c\/p\u003e\n\u003ch2\u003eA single point of contact for the installation and the maintenance of your buildings\u003c\/h2\u003e\n\u003cp\u003eAn HVAC contractor based in Montreal, AirGreen inc. sells, installs and maintains. For an owner or a manager, that means a single team from start to finish. It all begins with a \u003cstrong\u003efree on-site estimate:\u003c\/strong\u003e a review of the areas to be served, of the duct system, of the three-phase electrical service and of the location on the roof or at ground level. We calculate the load, prepare a clear quote, coordinate the lift and the access with you, then our crews install and commission the unit. After that, we can schedule the periodic maintenance of your equipment.\u003c\/p\u003e\n\u003cp\u003eOur crews travel quickly and efficiently everywhere on the island of Montreal, in Laval, in Longueuil as well as on the North Shore and the South Shore. For a plex, a small building or your offices, dial 514 316-2973 or use the online form at airgreen.ca.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367080571172,"sku":"PH3E48N00S31","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_PH3_00_PRINCIPALE_f92c6635-7b69-44a4-928c-b0827811f3de.png?v=1790963803"},{"product_id":"thermopompe-monobloc-york-ph3-de-5-tonnes-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York PH3 5 Ton | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eA large open-concept home: planning the capacity, the electrical service and the backup heat\u003c\/h2\u003e\n\u003cp\u003eKitchen, dining room and living room in one continuous space, open ceilings, large windows: an open-concept layout has plenty of charm, but it also means a large volume of air to cool and to heat. The YORK PH3 5 ton heat pump, with a rated capacity of 60,000 BTU\/h, is the largest single-phase model in the series. Choosing this unit well means planning three things at the same time: the home's \u003cstrong\u003eelectrical capacity\u003c\/strong\u003e, the \u003cstrong\u003ebackup heat\u003c\/strong\u003e and the distribution of 1,920 CFM of air. AirGreen guides the owners of large homes through each of these steps, in the Montreal, Laval and Longueuil area as well as on the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eA single outdoor unit for the whole living space\u003c\/h3\u003e\n\u003cp\u003eIn a \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e, the compressor, the coils and the blower that feeds the ducts are all in the same cabinet, outdoors, on a pad or on a roof curb. There is no furnace and no air handler to fit in the basement, which frees up space in a home where every room has a purpose. The cabinet, which measures 45.75 x 51.25 x 55 in. (width x depth x height), takes up the same floor area as the 3 and 4 ton models; only its height increases. It weighs 499 lb in operation and carries an AHRI 270 sound rating of 70.7 dBA.\u003c\/p\u003e\n\u003ch3\u003eThe performance of the 5 ton PH3\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eData\u003c\/th\u003e\n\u003cth\u003eIn cooling\u003c\/th\u003e\n\u003cth\u003eIn heating\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e57,500 BTU\/h (AHRI net cooling)\u003c\/td\u003e\n\u003ctd\u003e56,000 BTU\/h at 47 °F (8.3 °C); 33,700 BTU\/h at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e13.4 SEER2 and 11.1 EER2\u003c\/td\u003e\n\u003ctd\u003e6.7 HSPF2 and a COP of 3.4 at 47 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe model carries the number PH3E60N00S21 and its rated airflow is 1,920 CFM (ft³\/min). It runs on 208\/230 V single-phase, 60 Hz, and uses R-454B refrigerant, an A2L fluid with a low GWP (global warming potential), monitored by a factory-mounted refrigerant detection system.\u003c\/p\u003e\n\u003ch3\u003ePlanning the electrical capacity on single-phase\u003c\/h3\u003e\n\u003cp\u003eA home heated with electricity often already carries a heavy demand: range, water heater, baseboards, sometimes a charging station. Before adding a 5 ton heat pump and its backup heat, you have to know the numbers. According to the YORK guide, the 5 ton PH3 requires, without a heat kit, a circuit with a minimum circuit ampacity (MCA) of 43.5 A at 208 V or 39.3 A at 230 V, with a maximum overcurrent protection (MOP) of 70 A or 60 A. That protection takes the form of an HACR breaker or a time-delay fuse, completed by a field-installed disconnect.\u003c\/p\u003e\n\u003cp\u003eThe heat kit changes these values considerably. At 230 V, on a single power supply with a 20 kW kit, the minimum circuit ampacity climbs to 135.1 A and the maximum protection to 150 A. That is why we examine your panel and your electrical service before recommending a kit size, not after.\u003c\/p\u003e\n\u003ch3\u003eSizing the backup heat: the 6HK kits from 5 to 25 kW\u003c\/h3\u003e\n\u003cp\u003eThe heating capacity of a heat pump drops as the outdoor temperature falls: the 5 ton PH3 goes from 56,000 BTU\/h at 47 °F to 33,700 BTU\/h at 17 °F. The 6HK electric kit, installed inside the unit, fills the gap between that capacity and the heat loss of the home in cold weather. Here is what each kit actually delivers, depending on the supply voltage:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eKit\u003c\/th\u003e\n\u003cth\u003eStages\u003c\/th\u003e\n\u003cth\u003eAt 208 V\u003c\/th\u003e\n\u003cth\u003eAt 230 V\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 kW\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e3.6 kW (12,300 BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e4.4 kW (15,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8 kW\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e5.8 kW (19,700 BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e7.1 kW (24,100 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 kW\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e7.2 kW (24,600 BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e8.8 kW (30,100 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 kW\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e10.8 kW (36,900 BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e13.2 kW (45,100 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20 kW\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e14.4 kW (49,200 BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e17.6 kW (60,200 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25 kW\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e18 kW (61,500 BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e22 kW (75,200 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThree points guide our choice. First, the actual voltage of your service: at 208 V, a kit gives noticeably less heat than at 230 V. Second, the wiring method: up to 20 kW, a single-point wiring kit (S1-2SPWK005 at 230 V) can group the power supply, while the 25 kW kit requires multiple circuits. Third, the installation: with the 20 and 25 kW kits, the supply duct has to keep a 1 in. clearance over its first three feet, and the blower has to respect the minimum speed YORK prescribes for each kit. The two-stage kits bring the backup heat on in steps rather than all at once.\u003c\/p\u003e\n\u003ch4\u003eThrough the winter, on the heat pump side\u003c\/h4\u003e\n\u003cp\u003eIn heating mode, the outdoor coil builds up frost. The PH3 handles it with a \u003cstrong\u003edemand defrost\u003c\/strong\u003e board in which YORK has preloaded defrost curves matched to the capacities of the unit, so that it defrosts when needed rather than at fixed intervals. As for the backup heat kits, the guide requires them to be certified to the UL 60335-2-40 standard; the 6HK models are offered with a built-in service disconnect, depending on the version chosen.\u003c\/p\u003e\n\u003ch3\u003eDistributing 1,920 CFM through an open-concept space\u003c\/h3\u003e\n\u003cp\u003eIn a large space without partitions, the air has to travel long distances before it reaches the reading corner or the picture window. The indoor blower of the 5 ton PH3 is driven directly by a 1 HP ECM motor, and its cooling and heating speeds, set at the factory, are adjusted on site. We place the supply grilles where the heat gains and losses are greatest, near the glazed surfaces, and we plan a return grille large enough not to restrict the airflow. YORK also advises against connecting the unit to a duct system whose resistance, measured as external static pressure, exceeds 0.8 in. w.c.\u003c\/p\u003e\n\u003cp\u003eOn the heat exchange side, the air passes through a four-row indoor coil made entirely of aluminum. The outdoor coil, the largest in the series with 26.4 ft² of face area, has two rows of internally grooved copper tubes with enhanced-surface aluminum fins.\u003c\/p\u003e\n\u003ch2\u003eFrom the electrical service to commissioning: the AirGreen approach\u003c\/h2\u003e\n\u003cp\u003eFor a large home, we take the project in order. During the \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, we measure the open space, note the windows and the insulation, inspect the electrical panel and assess the ducts already in place or still to be built. We then calculate the heat gains and losses to confirm that 5 tons is the right size, and we choose the 6HK kit that completes the heat pump without overloading your electrical service. Our crews carry out the installation, the hookup and the commissioning, then we handle the maintenance of the unit season after season.\u003c\/p\u003e\n\u003cp\u003eOur team covers the island of Montreal, Laval, Longueuil as well as the North Shore and the South Shore. To book your free on-site estimate, call 514 316-2973 or send your request through the form on airgreen.ca: a member of our team will get back to you quickly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367082799396,"sku":"PH3E60N00S21","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_PH3_00_PRINCIPALE_e80d9dbe-aa54-49e4-85ea-1dbbecc23fc5.png?v=1790963785"},{"product_id":"thermopompe-monobloc-york-ph3-de-5-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York PH3 5 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eRestaurants, clinics and showrooms: 5 tons of capacity in a compact cabinet\u003c\/h2\u003e\n\u003cp\u003eA dining room full on a Friday night, a clinic whose waiting room never empties, a showroom lit by spotlights behind a large storefront window: these light commercial spaces give off a lot of heat and must still stay comfortable from morning until closing. The 5 ton YORK PH3 heat pump in the \u003cstrong\u003e208\/230 V three-phase\u003c\/strong\u003e version delivers 60,000 BTU\/h of rated capacity in a cabinet whose footprint is no larger than 45.75 x 51.25 in. Installed on the roof, it leaves all of the indoor floor space to your customers, and its vertical discharge fan throws the air upward, away from your terrace. AirGreen carries out this type of installation for businesses located in Montreal, in Laval and in Longueuil, as well as on the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eA high heat load, calculated precisely\u003c\/h3\u003e\n\u003cp\u003eIn a restaurant or a clinic, the heat does not come from the sun alone. Every person present, every light fixture, every piece of equipment running adds its share, and the occupants also bring moisture. The \u003cstrong\u003eheat load\u003c\/strong\u003e of such a space is therefore high and variable. The performance tables in the YORK guide break down the total capacity and the sensible capacity of the PH3 according to indoor and outdoor temperatures: we use them to confirm that the unit will remove both the heat and the moisture from your space. If the calculation confirms it, 5 tons in a single unit simplifies the installation; if not, we propose another configuration.\u003c\/p\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e brings the compressor, the coils and the supply fan together in a single outdoor cabinet. The supply and return ducts connect it to the space, from below through the roof curb or from the side. In winter, the same machine heats by reversing its cycle, and an electric kit can supplement its capacity.\u003c\/p\u003e\n\u003ch4\u003eA lot of moisture, so a lot of condensate\u003c\/h4\u003e\n\u003cp\u003eThe more moisture the unit removes, the more water it produces. Under the indoor coil, a corrosion-resistant, fully sealed pan collects and drains all the condensate, leaving no standing water; its design meets ASHRAE 62 (ventilation and indoor air quality). The 3\/4 in. female NPT drain connection is rigidly mounted for a leak-free hookup; we then route the drain to a suitable discharge point on the roof.\u003c\/p\u003e\n\u003ch3\u003eThe 5 ton three-phase PH3 in numbers\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel number\u003c\/td\u003e\n\u003ctd\u003ePH3E60N00S31 (YORK LX series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling capacity\u003c\/td\u003e\n\u003ctd\u003e57,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e56,000 BTU\/h, for a COP of 3.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e34,200 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy efficiency\u003c\/td\u003e\n\u003ctd\u003eEER2 of 11.1, SEER2 of 13.4 and HSPF2 of 6.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit airflow (rated)\u003c\/td\u003e\n\u003ctd\u003e1,825 CFM (ft³\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, three-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFootprint (width, depth, height)\u003c\/td\u003e\n\u003ctd\u003e45.75 in., 51.25 in. and 55 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e499 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound rating (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e72.0 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-454B, classified A2L, with a factory-installed detection system (RDS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe direct-drive indoor fan uses a 1 HP ECM motor. The indoor coil has four rows, and the outdoor coil, with 26.4 ft² of face area, is the largest in the PH3 line.\u003c\/p\u003e\n\u003ch3\u003eThe rooftop installation, step by step\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe support.\u003c\/strong\u003e We validate the roof and choose the curb: a YORK roof curb, NRCA approved, 8 or 14 in. high, or a transition kit if an existing curb from another generation or another manufacturer has to be kept.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe lift.\u003c\/strong\u003e The unit weighs 504 lb as shipped. Its perimeter base rails are drilled with lifting holes meant for the crane and protect the cabinet during transport.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe anchoring.\u003c\/strong\u003e The unit is secured to its structure with the YORK roof mounting kit, certified to resist wind loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe connections.\u003c\/strong\u003e The vertical openings fit between standard joists 24 in. on centre. On the electrical side, without a heat kit, the circuit must provide a minimum circuit ampacity of 29.5 A, protected at no more than 45 A by an HACR breaker or a time-delay fuse, with a field-installed disconnect.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe commissioning.\u003c\/strong\u003e We check the clearances, including 36 in. above the vertical discharge fan, then set the indoor fan speeds to suit your duct system.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFresh air, economizer and CO2 control\u003c\/h3\u003e\n\u003cp\u003eA densely occupied space needs outdoor air. For the PH3, YORK offers \u003cstrong\u003emodulating integrated economizers\u003c\/strong\u003e, in a vertical or a horizontal version, which can run at the same time as mechanical cooling. Their independent-blade dampers show a leakage rate below 1%, and the assembly includes a hood with a bird screen and a temperature sensor. Single or dual enthalpy sensors improve outdoor air management, and CO2 detection kits, mounted in the duct, on the unit or on the wall, command the economizer when CO2 goes past the preset limits. For simpler needs, a manual or motorized damper provides 0 to 50% outdoor air. One technical detail we check: according to YORK, if the return duct resistance is below 0.25 in. w.c., the unit delivers less air when the economizer runs entirely on outdoor air.\u003c\/p\u003e\n\u003ch4\u003eCooling even in cool weather\u003c\/h4\u003e\n\u003cp\u003eA packed room can call for cooling in spring or in fall. In its standard configuration, the PH3 cools down to an outdoor temperature of 55 °F (12.8 °C). The low ambient kit offered by YORK extends cooling operation down to 0 °F (-17.8 °C).\u003c\/p\u003e\n\u003ch3\u003eThree-phase backup heat\u003c\/h3\u003e\n\u003cp\u003eFor this model, the three-phase 6HK kits run from 10 to 25 kW. The 25 kW kit heats in two stages and delivers 22 kW at 230 V, which is 75,200 BTU\/h, or 18 kW at 208 V. The 20 and 25 kW kits include their own breakers, and the S1-2SPWK035 single point wiring kit makes it possible to bring only one power feed to the unit. With the 25 kW kit on a single feed, the minimum circuit ampacity rises to 92.0 A at 208 V or 98.7 A at 230 V, for a maximum overcurrent protection of 110 A: your electrician needs to know this before preparing the service.\u003c\/p\u003e\n\u003ch2\u003eYour commercial project, managed by AirGreen\u003c\/h2\u003e\n\u003cp\u003eIn a business, every day of work counts. So we prepare everything ahead of time. The \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e lets us assess your space, its occupancy, its equipment, the duct system, the roof and the three-phase electrical service. We calculate the load, recommend the options worth having, such as the economizer or the backup kit, and plan the lift with you. Our crews install, connect and commission the unit quickly and efficiently, and then we can look after the regular maintenance of your equipment.\u003c\/p\u003e\n\u003cp\u003eRestaurant owners, clinics and retailers, whether you are in Montreal, in Laval, in Longueuil or on one of the two shores, North Shore or South Shore: call us at 514\u0026nbsp;316-2973 or send your request on airgreen.ca to get your free on-site estimate and a detailed proposal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years on the compressor, 10 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367082832164,"sku":"PH3E60N00S31","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_PH3_00_PRINCIPALE_50b7975a-8505-47d4-9596-29e76890db5b.png?v=1790963764"},{"product_id":"thermopompe-monobloc-york-wn-de-3-tonnes-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WN 3 Ton | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eA 3 ton commercial rooftop unit, without moving to three-phase\u003c\/h2\u003e\n\u003cp\u003eIn many small commercial buildings in Montreal, Laval, Longueuil, the North Shore and the South Shore, the electrical service is single-phase. That is often the case for a neighbourhood convenience store, a professional's office, a service salon or a small unit on a commercial street. This YORK WN series \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e lets you install a 3 ton commercial rooftop unit directly on that supply, in \u003cstrong\u003e208\/230 V single-phase\u003c\/strong\u003e, without taking on work to bring in three-phase. At AirGreen, we assess it, install it, start it up and maintain it.\u003c\/p\u003e\n\u003ch3\u003eSingle-phase, a common reality in small commercial spaces\u003c\/h3\u003e\n\u003cp\u003eBringing three-phase into a small commercial space is a project in itself, with its own costs and delays. In the KE\/WN series, YORK offers exactly the 208\/230-1-60 voltage for the 3, 4 and 5 ton sizes. The 3 ton model shown here suits modest-sized spaces that need a rugged commercial-grade unit, with a galvanized steel cabinet, base rails and full electronic control.\u003c\/p\u003e\n\u003ch3\u003eThe whole system in one cabinet, connected to your ducts\u003c\/h3\u003e\n\u003cp\u003eA packaged heat pump brings together in one outdoor cabinet the scroll compressor, the outdoor coil, the indoor coil, the outdoor fan and the supply fan. The unit sits on the roof, on a roof curb, or on a pad at ground level, and connects directly to the supply and return \u003cstrong\u003educts\u003c\/strong\u003e of the space. Nothing goes inside: no furnace in the back room, no coil in the ceiling, no refrigerant piping to run through the walls. For a business where every square foot is selling space, that is an immediate space saving. Each unit is also fully charged, wired, piped and tested at the factory, which simplifies installation on site.\u003c\/p\u003e\n\u003ch3\u003eSpecifications of the WN036C00B1AAAAA1A1 model\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal capacity: 3 tons (36,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 38,000 BTU\/h, EER2 of 11.4\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 36,000 BTU\/h, COP of 3.3\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 21,000 BTU\/h, COP of 2.1\u003c\/li\u003e\n\u003cli\u003eSeasonal efficiency: 13.4 SEER2 and 6.7 HSPF2 (14.0 SEER and 8.0 HSPF under the former rating method, as published by YORK)\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 1,250 CFM\u003c\/li\u003e\n\u003cli\u003eSupply: 208\/230 V single-phase, 60 Hz (applied voltage from 187 to 252 V)\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 44.88 x 82.25 x 32.63 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 610 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270 standard): 83 dB(A)\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B, an A2L refrigerant with low global warming potential\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat your electrical panel has to allow for\u003c\/h3\u003e\n\u003cp\u003eAccording to the electrical tables in the YORK technical guide, this unit (standard belt-drive indoor fan, no powered convenience outlet) calls for a minimum circuit ampacity (MCA) of 26.3 A, with a fuse or breaker of no more than 35 A, when no electric heat kit is added.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectric backup heat\u003c\/strong\u003e changes the calculation. The kits compatible with this model in single-phase run from E05 to E20, that is from 5 to 20 kW. With the largest one, the MCA reaches 121.8 A at 208 V and 136.7 A at 230 V. YORK also states that the elements are rated at their nominal voltage: wired at 208 V, they deliver about 75% of their rated capacity. Before choosing the kit, we therefore check the capacity of your electrical service, the space available in the panel and the voltage actually measured at the building. The disconnect, supplied on site, is installed at the location the manufacturer clearly identifies on the cabinet.\u003c\/p\u003e\n\u003ch3\u003eA standalone control, simple to use day to day\u003c\/h3\u003e\n\u003cp\u003eThe version offered here uses the \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control in standalone mode. It works with a conventional thermostat wired to a screw terminal block or with a zone sensor, without a building management system. Factory-installed sensors measure the supply air, the return air and the outdoor air. The built-in LCD display, with its navigation joystick, shows the unit's status, the current mode, those temperatures and the fault codes.\u003c\/p\u003e\n\u003cp\u003eThe USB port allows data logging, reading of current and past faults, software updates as well as self-test and start-up reports. The board keeps the last five alarms, even after a power failure. It also applies the \"three times, then shutdown\" logic: the high and low pressure switches and the freeze protections have to trip three times in two hours before the compressor is locked out, which avoids a service call for an isolated trip. An anti-short-cycle delay and programmable minimum run times protect the compressor when the store door opens and closes all day long.\u003c\/p\u003e\n\u003cp\u003eAnother advantage for a convenience store, where the refrigerated cases give off heat even in spring: the built-in low ambient control lets the compressor cool down to 0 °F (-17.8 °C) outdoor, with no additional accessory.\u003c\/p\u003e\n\u003ch3\u003eThe configuration supplied and the other factory option\u003c\/h3\u003e\n\u003cp\u003eThe WN036C00B1AAAAA1A1 model is supplied with a belt-drive indoor fan (standard static pressure), the RDS refrigerant detector, the standalone Smart Equipment control, standard coils and 1 in. disposable filters, with no economizer and no optional sensor. The RDS monitors for R-454B inside the cabinet: in case of a leak, it raises an alarm and automatically starts a dilution sequence.\u003c\/p\u003e\n\u003cp\u003eYORK also builds, still in single-phase, the WN036C00B1CAACA1A1. That configuration adds an economizer (without a barometric relief damper) and the BACnet MS\/TP, Modbus or N2 communication card. The economizer can bring in up to 100% outdoor air to cool the space without the compressor when the weather allows. We confirm the right configuration during the estimate, based on your ventilation needs and the use of your space.\u003c\/p\u003e\n\u003ch3\u003eInstallation notes for a small commercial roof\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof curb:\u003c\/strong\u003e the YORK 8 in. or 14 in. curbs, meeting NRCA requirements, nest inside the base rails and include a nailing strip and duct supports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDucts:\u003c\/strong\u003e the connection is made from underneath, through the roof curb, or horizontally at the back, by simply removing the panels provided for that purpose.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e allow 72 in. clear above the unit for the condenser air discharge, with no overhang or obstruction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate:\u003c\/strong\u003e to limit drain freezing in winter, YORK offers as an option a bottom drain connection, which runs inside the roof curb.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilters:\u003c\/strong\u003e three filters to replace (two 15 x 20 in., one 14 x 25 in.); since the rack also accepts a 2 in. thickness, thicker pleated filters can be installed later with no modification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating:\u003c\/strong\u003e like any air-to-air heat pump, capacity drops as it gets colder, from 36,000 BTU\/h at 47 °F to 21,000 BTU\/h at 17 °F. The electric kit takes over; we size it according to the actual heat loss of your space.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eYour small business in good hands with AirGreen\u003c\/h2\u003e\n\u003cp\u003eEverything starts with a free on-site estimate. We record the condition of the roof and the ducts, check the single-phase electrical service, calculate the heating and cooling loads, then propose the backup heat kit and the factory configuration that suit. Our crews then handle delivery, hoisting, connections and start-up, then seasonal maintenance: filters, coils, belt and reading the alarms recorded by the control.\u003c\/p\u003e\n\u003cp\u003eAirGreen inc. is a Montreal HVAC contractor that sells and installs the equipment it recommends. Whether your business is in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, call 514 316-2973 or use the form on airgreen.ca to book your free on-site estimate. You will quickly receive a clear, detailed quote.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367113863460,"sku":"WN036C00B1AAAAA1A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUNLINE_WN_XN_00_PRINCIPALE_94983250-1a6b-475a-9bcf-c2950a56a6cf.png?v=1790963746"},{"product_id":"thermopompe-monobloc-york-wn-de-3-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WN 3 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eA rooftop unit that speaks the language of your building management system\u003c\/h2\u003e\n\u003cp\u003eAn office suite on the second floor of a commercial building, a storefront on a busy street, a professional practice in a small shopping centre: these spaces are often supplied in \u003cstrong\u003e208\/230 V three-phase\u003c\/strong\u003e and, in many cases, tied into a building management system. This 3 ton YORK WN packaged heat pump comes from the factory with the \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control and its BACnet MS\/TP, Modbus or N2 communication card. The manager sees it and drives it like the rest of the equipment. AirGreen installs it and commissions it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\u003ch3\u003eOne card, three communication protocols\u003c\/h3\u003e\n\u003cp\u003eOn this model, the communication card is installed at the factory. To all the functions of the Smart Equipment control it adds a BACnet MS\/TP gateway, which can be programmed in Modbus or in N2. In practice, the unit fits into the network already in place in the building rather than running on its own. For an owner who manages several tenants, it means being able to follow the rooftop units from the management station and to line up their schedules with those of the building.\u003c\/p\u003e\n\u003cp\u003eOccupied mode is commanded from the thermostat or from the management system. Smart Equipment boards leave the factory with a jumper between the R and OCC terminals; as long as it is in place, the unit stays in occupied mode permanently. Our technicians remove it at commissioning so that your occupancy schedules are actually respected. The terminal block also includes an OCC terminal, which receives the occupancy signal from the thermostat, and an X terminal, which passes fault states to compatible thermostats for display.\u003c\/p\u003e\n\u003ch3\u003eWhat the manager sees and what the manager can set\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSupply air, return air and outdoor air sensors installed at the factory, with no additional field wiring.\u003c\/li\u003e\n\u003cli\u003eA built-in LCD screen, with a joystick and buttons, that shows the status of the unit, the current mode, the temperatures and the fault codes.\u003c\/li\u003e\n\u003cli\u003eA USB port for data logging, the fault history, software updates and the self-test and start-up reports.\u003c\/li\u003e\n\u003cli\u003eEnergy consumption tracking functions that make it possible to adjust operation according to the hours and the occupancy rate.\u003c\/li\u003e\n\u003cli\u003eFully programmable fan delays on start-up and on shutdown, set separately for heating and for cooling.\u003c\/li\u003e\n\u003cli\u003eAn option to lock out the compressors when the outdoor temperature is low, and mechanical cooling possible down to 0 °F (-17.8 °C) thanks to the built-in low ambient control.\u003c\/li\u003e\n\u003cli\u003eMemory of the last five alarms, kept even through a power failure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe packaged principle, seen from an office suite\u003c\/h3\u003e\n\u003cp\u003eA packaged heat pump groups the scroll compressor, the two coils and the two fans in a single cabinet installed outdoors, usually on the roof. It connects to the supply and return \u003cstrong\u003educts\u003c\/strong\u003e that serve the workstations, the meeting room or the sales floor. For your occupants, that means a ceiling free of any mechanical equipment and maintenance done on the roof, without disturbing employees or customers. Fan performance measurement ports, located outside the cabinet, even make it possible to check the airflow without removing a panel.\u003c\/p\u003e\n\u003ch3\u003eTechnical data for the WN036C00B2AAACA1A1 model\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated capacity\u003c\/td\u003e\n\u003ctd\u003e3 tons (36,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e38,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h, COP of 3.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e21,000 BTU\/h, COP of 2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e13.4 SEER2, 6.7 HSPF2 and 11.4 EER2 (14.0 SEER and 8.0 HSPF, as published)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated airflow\u003c\/td\u003e\n\u003ctd\u003e1,250 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e208\/230 V three-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (width x length x height)\u003c\/td\u003e\n\u003ctd\u003e44.88 x 82.25 x 32.63 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e610 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor sound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e83 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L, low global warming potential)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eThree-phase supply: the numbers for your electrician\u003c\/h3\u003e\n\u003cp\u003eAccording to the YORK electrical tables, this model with the standard belt-drive blower, without a powered convenience outlet, calls for an MCA (minimum circuit ampacity) of 20.8 A and a fuse or breaker of no more than 30 A without electric heat. The compatible backup heat kits run from E05 to E20; with the E20 kit, the MCA rises to 75.9 A at 208 V and 84.6 A at 230 V. At 208\/230 V, the kits of 16 kW and up work in two stages, and all of them are wired for a single-point power supply. The allowable applied voltage runs from 187 to 252 V.\u003c\/p\u003e\n\u003cp\u003eYORK also offers from the factory a phase monitor that shuts the unit down on a phase fault to keep it from being damaged, a dirty filter switch and smoke detectors. These sensors are not part of the configuration presented here; we tell you which ones are relevant for your building.\u003c\/p\u003e\n\u003ch3\u003eThree factory configurations in three-phase\u003c\/h3\u003e\n\u003cp\u003eOffered on this page, the WN036C00B2AAACA1A1 is built around communication: BACnet \/ Modbus \/ N2 card and RDS refrigerant detector installed at the factory, belt-drive supply blower (standard static pressure), standard coils and 1 in. disposable filters, but no economizer. YORK builds two three-phase variants:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWN036C00B2CAACA1A1:\u003c\/strong\u003e adds an economizer (without a barometric relief damper), with AMCA class 1A low-leak dampers and up to 100% outdoor air.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWN036C00B2CBACA1A1:\u003c\/strong\u003e adds the same economizer as well as a factory-installed disconnect, on top of the RDS.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn both of these versions, the economizer is fully integrated with the Smart Equipment control, which manages the changeover between mechanical cooling and outdoor air. We confirm the right configuration during the estimate, after reviewing your fresh air needs and your control architecture.\u003c\/p\u003e\n\u003ch3\u003eGetting the installation right in an occupied building\u003c\/h3\u003e\n\u003cp\u003eWe plan the crane lift using the lifting holes in the full-length base rails, and we coordinate the network connection with your controls integrator. The duct connections are made from below or horizontally, even with an economizer. The power wiring and the control wiring enter through separate openings, on the side or from below, which limits the number of roof penetrations.\u003c\/p\u003e\n\u003cp\u003eThe belt-drive blower has an adjustable-pitch drive pulley: at commissioning, we set the airflow to the actual static pressure of your ducts. In winter, the heat pump heats the suite first, with 36,000 BTU\/h at 47 °F (8.3 °C) and 21,000 BTU\/h at 17 °F (-8.3 °C). When the demand goes beyond what it can deliver, the electric kit tops up the heat. We size it from the real heat loss, taking into account the glazing of a storefront and the schedules programmed in the management system.\u003c\/p\u003e\n\u003ch2\u003eAirGreen, your HVAC team for offices and businesses\u003c\/h2\u003e\n\u003cp\u003eOur free on-site estimate includes the roof survey, the check of the three-phase supply, the load calculation and a review of your building management system with your integrator. Our crews install, connect and commission the unit, then handle its scheduled maintenance.\u003c\/p\u003e\n\u003cp\u003eFor an office suite or a storefront in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, reach us at 514 316-2973 or write to us through the form on airgreen.ca. A member of our team will call you back quickly to set up the visit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367114191140,"sku":"WN036C00B2AAACA1A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUNLINE_WN_XN_00_PRINCIPALE_d5cf4873-5419-441f-a25f-2dfed8f9a538.png?v=1790963728"},{"product_id":"thermopompe-monobloc-york-wn-de-3-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WN 3 Ton 575V | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eConnected directly to the 575 V of your plant, with no transformer\u003c\/h2\u003e\n\u003cp\u003eIn Quebec's industrial parks, \u003cstrong\u003e575 V three-phase\u003c\/strong\u003e power is very common. Yet the administrative offices, the employee lounge or the cafeteria of a plant need the same comfort as an office building. Without a unit designed for that voltage, you have to add a step-down transformer, which takes up space and adds weight to the project. This 3 ton YORK WN \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e connects directly to the building's 575 V service. AirGreen offers it and installs it in industrial buildings in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eWhat 575 V changes for your electrical installation\u003c\/h3\u003e\n\u003cp\u003eAccording to the YORK electrical tables, this model (standard belt-drive fan, without a powered convenience outlet) calls for a minimum circuit ampacity (MCA) of only 8 A, with a fuse of 15 A at most, when no electric heat is added. For comparison, the same unit in 208\/230 V three-phase calls for 20.8 A. The allowable applied voltage runs from 540 to 630 V.\u003c\/p\u003e\n\u003cp\u003eFor backup heat, three electric kits are offered in 575 V: E10, E15 and E20. With the largest one, the MCA reaches 33.5 A and the maximum fuse 35 A. In 575 V, kits of 20 kW and up work in two stages, which avoids calling on the full capacity at once when demand is moderate. The nickel-chrome elements have an automatic reset limit, and the heat section slides out of the unit for maintenance.\u003c\/p\u003e\n\u003ch3\u003eComfortable offices and employee lounge, in the heart of the plant\u003c\/h3\u003e\n\u003cp\u003eA packaged heat pump brings together in a single outdoor cabinet the scroll compressor, the outdoor coil, the indoor coil and the two fans. Set on the roof of the administrative block or on a pad along the wall, it feeds a network of \u003cstrong\u003educts\u003c\/strong\u003e separate from the one in the production area. In summer, it cools the offices; in winter, it reverses its cycle to heat, and the electric kit tops up the heat in deep cold. Everything runs on electricity, with no combustion and no vent to maintain.\u003c\/p\u003e\n\u003cp\u003eThe 3 ton capacity suits a group of offices or a medium-size employee lounge well. The load calculation remains the decisive step: the occupancy, the heat given off by nearby equipment and the glazing can tip the choice toward 4 or 5 tons. Since the 3 to 5 ton models share the same cabinet and the same roof curb, that choice can even be made after the curb is installed.\u003c\/p\u003e\n\u003ch3\u003eTechnical specifications of the WN036C00B5CAACA1A1 model\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated capacity: 3 tons (36,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 38,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 36,000 BTU\/h, COP of 3.3\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 21,000 BTU\/h, COP of 2.1\u003c\/li\u003e\n\u003cli\u003eEfficiencies: 11.4 EER2, 13.4 SEER2 and 6.7 HSPF2 (14.0 SEER and 8.0 HSPF as published)\u003c\/li\u003e\n\u003cli\u003eRated airflow: 1,250 CFM\u003c\/li\u003e\n\u003cli\u003ePower supply: 575 V three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 44.88 x 82.25 x 32.63 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 610 lb (base unit)\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270 standard): 83 dB(A)\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B (A2L class, low global warming potential), monitored by the built-in RDS detector\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAn economizer already installed at the factory\u003c\/h3\u003e\n\u003cp\u003eThis is the factory configuration we offer in 575 V for the 3 ton WN, and it is complete: belt-drive indoor fan (standard static pressure), economizer without barometric relief damper, RDS refrigerant detector, Smart Equipment control with BACnet MS\/TP, Modbus or N2 communication card, standard coils and 1 in. disposable filters. During the estimate, we confirm with you that it meets the needs of your space.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eeconomizer\u003c\/strong\u003e can bring in up to 100% outdoor air. When the outdoor air is cool enough, it cools the offices without running the compressor, a welcome advantage when the offices stay warm in spring and in fall. Its low-leakage AMCA 511 Class 1A dampers hold leakage to 3 CFM per ft² at 1 in. of static pressure, and every economizer goes through a 60,000 cycle test. The spring-return modulating damper motors close the dampers completely during a power failure. A barometric relief damper, with rain hood and bird screen, can be added to relieve the pressure build-up in the space.\u003c\/p\u003e\n\u003ch3\u003eA control that integrates with the building automation\u003c\/h3\u003e\n\u003cp\u003eThe factory-installed communication card adds to the \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control a BACnet MS\/TP gateway that can also be programmed to N2 or to Modbus, the latter being well known in industrial settings. On site, the LCD screen displays the supply air, return air and outdoor air temperatures as well as the fault codes, and the USB port is used to retrieve the fault history and a start-up report, and to update the software. The board monitors each pressure switch and each freeze protection independently, applies an anti-short-cycle delay and keeps the last five alarms, even after a power outage.\u003c\/p\u003e\n\u003ch3\u003eProcess cooling: a check to make before buying\u003c\/h3\u003e\n\u003cp\u003eThe Smart Equipment control allows cooling down to 0 °F (-17.8 °C) outdoors when the unit serves people's comfort. For an electrical room or a computer room, YORK asks that its applications department be consulted, and accessories may be required for stable operation below 30 °F (-1.1 °C). If your offices sit next to a room of that type, we make that check with the manufacturer before proposing the unit to you.\u003c\/p\u003e\n\u003ch3\u003eOptions for demanding industrial environments\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor or indoor coils with an epoxy coating (E-Coat) against corrosion, offered as a factory option by YORK.\u003c\/li\u003e\n\u003cli\u003eCoil guard and hail guard, installed in the field.\u003c\/li\u003e\n\u003cli\u003eStainless steel condensate pan for corrosive environments.\u003c\/li\u003e\n\u003cli\u003eGalvanized steel cabinet, powder paint finish proven by a 750-hour salt spray test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLifting and installation on an industrial roof\u003c\/h3\u003e\n\u003cp\u003eOn a plant roof, access is often by crane: the unit rests on permanently fixed base rails, drilled for lifting and reachable by forklift from three sides, which also protect it during transport. The duct connections are made from below or horizontally, and the power supply enters from the side or from below. Plan for 72 in. of clear space above the unit for the condenser air discharge.\u003c\/p\u003e\n\u003ch2\u003eAirGreen, a single point of contact for the comfort of your industrial offices\u003c\/h2\u003e\n\u003cp\u003eThe free on-site estimate is the first step: a survey of the roof or of the location at grade, a check of the 575 V distribution, the load calculation for the offices and the choice of heat kit. Our teams then coordinate the delivery, the lift, the connections and the start-up, then the planned maintenance of the filters, the belts and the economizer.\u003c\/p\u003e\n\u003cp\u003eAn HVAC contractor based in Montreal, AirGreen inc. works in the industrial parks of Montreal, Laval, Longueuil, the North Shore and the South Shore. Call us at 514 316-2973 or fill out the form on airgreen.ca; we will get back to you quickly with a precise quote.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367121301796,"sku":"WN036C00B5CAACA1A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUNLINE_WN_XN_00_PRINCIPALE_82fdda26-d75c-4b3b-bf94-bbf52f6a9535.png?v=1790963708"},{"product_id":"thermopompe-monobloc-york-wn-de-4-tonnes-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WN 4 Ton | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eComfort in a hall that fills up and empties out as the week goes by\u003c\/h2\u003e\n\u003cp\u003eA community hall, a place of worship or the premises of a non-profit lives at the pace of its activities: almost empty on a Tuesday afternoon, packed for a fundraising dinner, a celebration or a general meeting. Many of these buildings, in Montreal, Laval, Longueuil, on the North Shore as well as the South Shore, have only a single-phase electrical service. This 4 ton YORK WN \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e runs on \u003cstrong\u003e208\/230 V single-phase\u003c\/strong\u003e and its Smart Equipment control includes protections that spare the compressor despite these variations. AirGreen installs it, programs it to your schedule and maintains it.\u003c\/p\u003e\n\u003ch3\u003eVariable occupancy, settings that follow along\u003c\/h3\u003e\n\u003cp\u003eWhen a hall fills up, the temperature climbs quickly; when it empties out, demand drops. Without protection, the compressor would risk starting and stopping over and over. The control includes an \u003cstrong\u003eanti-short-cycle delay\u003c\/strong\u003e and programmable minimum run times that protect the compressor against these overly brief cycles. For testing, our technicians can temporarily bypass this delay at the press of a button.\u003c\/p\u003e\n\u003cp\u003eThe fan delays on start-up and on shutdown are fully programmable, and the heating ones are independent of the cooling ones. Every unit leaves the factory with default values suited to its configuration; we then adjust them to the volume of your hall and to the location of the supply grilles. Occupied mode, for its part, is driven by the thermostat: its OCC output tells the unit when the hall is occupied according to the programmed schedule.\u003c\/p\u003e\n\u003ch4\u003eWhat we program at start-up\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003eRemoval of the factory-installed jumper between terminals R and OCC, so that the thermostat's occupancy schedule is actually taken into account.\u003c\/li\u003e\n\u003cli\u003eThe fan delays in heating and in cooling, according to the height of the hall and the location of the grilles.\u003c\/li\u003e\n\u003cli\u003eThe minimum run times of the compressor.\u003c\/li\u003e\n\u003cli\u003eThe economizer setpoint and, where needed, the compressor lockout when outdoor air is enough to cool.\u003c\/li\u003e\n\u003cli\u003eVerification of the airflow and of the operation of the electric heat kit.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFresh air for large gatherings\u003c\/h3\u003e\n\u003cp\u003eThe WN048C00B1CAACA1A1 configuration shown here includes a factory-installed \u003cstrong\u003eeconomizer\u003c\/strong\u003e, without a barometric relief damper. It can bring in up to 100% outdoor air: when the hall is full and the air outside is cool, it cools without running the compressor. Its AMCA 511 class 1A low-leakage dampers and its spring-return modulating motors are fully managed by the Smart Equipment control. For a heavily used hall, a field-installed CO2 sensor can automatically take priority over the economizer command when the CO2 level goes above the set limits. A barometric relief damper can also be added to avoid over-pressurization.\u003c\/p\u003e\n\u003cp\u003eFor the rest, the unit comes from the factory with the RDS refrigerant detector and the BACnet MS\/TP, Modbus or N2 communication card; its supply blower is belt-driven (standard static pressure), its coils are of standard build and its disposable filters are 1 in. thick. In single-phase, this is the only configuration we offer in the 4 ton size, and at the estimate we confirm with you that it meets the needs of your building.\u003c\/p\u003e\n\u003ch3\u003eA refrigerant monitored at all times\u003c\/h3\u003e\n\u003cp\u003eR-454B is an A2L refrigerant, that is, mildly flammable, with a low global warming potential. In a building that welcomes the public, the RDS refrigerant detector supplied with the unit provides continuous monitoring. Its sensors, wired to the control, set off an alarm as soon as they detect in the cabinet a concentration corresponding to 25% of the lower flammability limit, then automatically start a dilution sequence. This protection comes on top of the high and low pressure switches, the freeze protections and the internal protection of the compressor.\u003c\/p\u003e\n\u003ch3\u003eA single cabinet, on the roof or at ground level\u003c\/h3\u003e\n\u003cp\u003eA packaged heat pump houses the scroll compressor, the coils and the fans in the same outdoor cabinet, connected to the supply and return ducts of the hall. No mechanical equipment takes up space in the basement or the sacristy. If the roof is sloped, as is often the case with a church, the unit can rest on a ground pad or on steel beams; the duct connections are then made horizontally, from the back.\u003c\/p\u003e\n\u003ch3\u003eModel specifications\u003c\/h3\u003e\n\u003ch4\u003ePerformance\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNominal capacity: 4 tons (48,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 47,000 BTU\/h, EER2 of 11.2\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 44,000 BTU\/h, COP of 3.0\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 26,000 BTU\/h, COP of 2.05\u003c\/li\u003e\n\u003cli\u003e13.4 SEER2 and 6.7 HSPF2; 14.0 SEER and 8.0 HSPF, as published by YORK\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 1,450 CFM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInstallation\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003ePower supply: 208\/230 V single-phase, 60 Hz (applied voltage from 187 to 252 V)\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 44.88 x 82.25 x 32.63 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 616 lb\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B, an A2L refrigerant with a low global warming potential\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSingle-phase and backup heat: the calculations to run\u003c\/h3\u003e\n\u003cp\u003eAccording to the YORK electrical tables, this model calls for a minimum circuit ampacity (MCA) of 37.5 A and a fuse or a breaker of no more than 50 A without electric heat. In single-phase, YORK offers the E05 to E20 kits for this size; with the E20, the MCA reaches 133 A at 208 V and 147.9 A at 230 V. YORK also requires a minimum airflow of 1,200 CFM with electric heat. Since the capacity of the heat pump goes from 44,000 BTU\/h at 47 °F to 26,000 BTU\/h at 17 °F, the choice of kit follows from a heat loss calculation, weighed against the capacity of your electrical service.\u003c\/p\u003e\n\u003ch3\u003eDiscretion and the neighbours\u003c\/h3\u003e\n\u003cp\u003eYORK does not publish an AHRI 270 sound rating for the 4 ton size. The compressor does, however, have internal spring isolation and sound insulation that reduce vibration and noise, and it rests on its own isolated mount. The outdoor fan blows vertically. We choose the location with the windows of the hall and the neighbouring houses in mind.\u003c\/p\u003e\n\u003ch3\u003eSimple maintenance for a building run by volunteers\u003c\/h3\u003e\n\u003cp\u003eThe LCD screen shows the status of the unit and the fault codes, and the board keeps the last five alarms, even after a power failure. The “three times, then lockout” logic keeps an isolated trip of a pressure switch from locking out the compressor. On our visits, we replace the filters (two 15 x 20 in. and one 14 x 25 in.), clean the coils, check the belt and the economizer, then review the fault history through the USB port.\u003c\/p\u003e\n\u003ch2\u003eTrust AirGreen with the comfort of your hall\u003c\/h2\u003e\n\u003cp\u003eThe first visit is a free on-site estimate: we examine the roof or the location at ground level, the single-phase service and the ducts, then we calculate the loads according to the actual occupancy of the hall. Our teams install, program and commission the unit, then look after its maintenance.\u003c\/p\u003e\n\u003cp\u003eCommittees, parish councils and community organizations in Montreal, Laval, Longueuil, on the North Shore and on the South Shore can reach us at 514 316-2973 or through the form on airgreen.ca. We answer quickly and provide a clear quote, easy to present to your board of directors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367121334564,"sku":"WN048C00B1CAACA1A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUNLINE_WN_XN_00_PRINCIPALE_6d49b0e1-afeb-4f81-9432-15e658c6ebf9.png?v=1790963690"},{"product_id":"thermopompe-monobloc-york-wn-de-4-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WN 4 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eFresh, well-filtered air for daycare rooms and classrooms\u003c\/h2\u003e\n\u003cp\u003eIn a daycare, a CPE, an elementary school or a school annex, air quality counts as much as temperature. Children spend the day in densely occupied rooms, where the outdoor air supply, the filtration and the regularity of the maintenance are decisive. This 4 ton YORK WN packaged heat pump, powered in \u003cstrong\u003e208\/230 V three-phase\u003c\/strong\u003e, heats and cools these spaces from a single unit installed on the roof. AirGreen offers it to institutions in Montreal, Laval, Longueuil, the North Shore and the South Shore, with a maintenance plan matched to the institution's calendar.\u003c\/p\u003e\n\u003ch3\u003eA packaged heat pump serving a school annex\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e brings together the scroll compressor, the coils and the fans in a single outdoor cabinet, tied to the supply and return duct system. For an annex or a pavilion, it is a sensible solution: no mechanical room to build, no noisy equipment in the rooms and all the maintenance is done outside, without disturbing the groups. In summer, the unit cools; in winter, it heats, with a field-installed electric backup kit for the coldest days.\u003c\/p\u003e\n\u003ch3\u003eOutdoor air up to 100%: choosing the right configuration\u003c\/h3\u003e\n\u003cp\u003eOne point to note: the WN048C00B2AAACA1A1 shown on this page has no economizer. It ships with the BACnet MS\/TP, Modbus or N2 communication card, the RDS refrigerant detector, a belt-driven supply blower (standard static pressure), standard coils and 1 in. disposable filters. For a daycare room or a classroom, where the fresh air supply is central, YORK builds two other three-phase versions at the factory:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWN048C00B2CAACA1A1:\u003c\/strong\u003e adds a factory-installed economizer (without a barometric relief damper).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWN048C00B2CBACA1A1:\u003c\/strong\u003e adds the same economizer and a factory-installed disconnect switch, on top of the RDS.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003eeconomizer\u003c\/strong\u003e admits up to 100% outdoor air. Its spring-return modulating motors open the outdoor air dampers as the return dampers close, and the changeover between mechanical cooling and outdoor air is set by the outdoor dry-bulb temperature. The AMCA 511 class 1A low-leakage dampers, tested over 60,000 cycles, are designed to exceed the requirements of ASHRAE 90.1 and of the IECC. An economizer can also be added in the field on the model shown here. We confirm the right configuration during the estimate, according to the ventilation needs of your rooms.\u003c\/p\u003e\n\u003ch3\u003eFiltration: the 2 in. filter option\u003c\/h3\u003e\n\u003cp\u003eThe unit takes two 15 x 20 in. filters and one 14 x 25 in. filter, reachable through a removable door. The rack accepts 1 in. or 2 in. filters. Standard units ship with 1 in. disposable filters, and YORK offers 2 in. MERV 8 pleated filters as a factory option. At a maintenance visit, we can therefore switch to 2 in. pleated filters. Since the blower performance tables are established with 1 in. filters, we then check the static pressure and adjust the adjustable-pitch drive pulley to keep the right airflow.\u003c\/p\u003e\n\u003cp\u003eThe condensate pan is internally sloped and meets the ASHRAE 62-89 self-draining standard, which prevents standing water. A dirty filter switch, offered as a factory option or as an accessory, lights the thermostat's fault indicator when the pressure drop across the filters becomes abnormally high.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eWN048C00B2AAACA1A1\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e4 tons (48,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e47,000 BTU\/h, EER2 of 11.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e44,000 BTU\/h, COP of 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e26,000 BTU\/h, COP of 2.05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeasonal efficiency\u003c\/td\u003e\n\u003ctd\u003e13.4 SEER2 and 6.7 HSPF2 (14.0 SEER and 8.0 HSPF, as published)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e1,450 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e208\/230 V three-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (width x length x height)\u003c\/td\u003e\n\u003ctd\u003e44.88 x 82.25 x 32.63 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e616 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-454B, an A2L with a low global warming potential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eA control your buildings department can follow\u003c\/h3\u003e\n\u003cp\u003eThe factory-installed communication card links the \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control to the building management system over BACnet MS\/TP, or over Modbus or N2 after programming. The buildings department of a school service centre or the manager of a CPE can then fit the unit into its schedules: occupied mode is commanded by the thermostat or by the management system, once the factory-installed R-OCC jumper is removed. Supply, return and outdoor air sensors are supplied as standard, and the LCD display shows the temperatures, the current mode and the fault codes. The anti-short-cycle delay and the programmable fan delays round out these settings.\u003c\/p\u003e\n\u003ch3\u003eMaintenance planned around the institution's calendar\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eBefore the heating season:\u003c\/strong\u003e filter replacement, check of the electric kit, of the limit controls and of the operation in heat pump mode.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIn spring:\u003c\/strong\u003e coil cleaning, check of the condensate drain, of the belt and, where applicable, of the economizer dampers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAt every visit:\u003c\/strong\u003e reading the fault codes on the LCD display and pulling the history through the USB port; the board keeps the last five alarms, even after a power failure.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eProtections designed for places used by children\u003c\/h3\u003e\n\u003cp\u003eThe RDS refrigerant detector monitors the cabinet continuously; if it detects R-454B, it triggers an alarm and automatically starts a dilution sequence. YORK also offers optional smoke detectors in the supply air or the return air, which cut the power to the control in the presence of smoke, as well as security bars to install in the supply and return openings to prevent access to the ducts.\u003c\/p\u003e\n\u003ch3\u003eThree-phase power supply and backup heat\u003c\/h3\u003e\n\u003cp\u003eAccording to the YORK electrical tables, this model calls for a minimum circuit ampacity (MCA) of 23.1 A and a fuse or a breaker of at most 30 A with no electric heat. With the E20 kit, the largest offered for this size, the MCA rises to 78.2 A at 208 V and 86.9 A at 230 V. A minimum airflow of 1,200 CFM is required with electric heat. On the heating side, the heat pump delivers 44,000 BTU\/h at 47 °F and 26,000 BTU\/h at 17 °F; the electric kit, chosen between E05 and E20, tops up the heat supply according to the losses calculated for your rooms.\u003c\/p\u003e\n\u003ch2\u003eWork planned with your management\u003c\/h2\u003e\n\u003cp\u003eThe process begins with a free on-site estimate: roof survey, check of the power supply, load calculation based on the occupancy of the rooms and choice of the configuration with or without an economizer. We then plan the work with your management, outside of activity hours when possible, and we handle the commissioning and the maintenance.\u003c\/p\u003e\n\u003cp\u003eDaycares, CPEs, schools and school service centres in Montreal, Laval, Longueuil, the North Shore and the South Shore can call us at 514 316-2973 or fill out the form on airgreen.ca. We answer quickly to set up the visit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367121858852,"sku":"WN048C00B2AAACA1A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUNLINE_WN_XN_00_PRINCIPALE_4381d82a-9ae2-476c-b443-40f3a9ab37e2.png?v=1790963670"},{"product_id":"thermopompe-monobloc-york-wn-de-4-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WN 4 Ton 575V | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eMezzanine offices cooled and heated from the warehouse roof\u003c\/h2\u003e\n\u003cp\u003eIn many warehouses and plants, the offices sit on a mezzanine above shipping or the shop floor. These enclosed rooms need their own system: warehouse air, often hot in summer and cold in winter, is not suited to office work. This 4-ton YORK WN \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e, fed directly at \u003cstrong\u003e575 V three-phase\u003c\/strong\u003e, is installed on the roof above the mezzanine or at grade, and serves these offices through a dedicated duct system. AirGreen plans the lift, the connections and the commissioning in industrial buildings in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eWhy a packaged unit suits mezzanine offices\u003c\/h3\u003e\n\u003cp\u003eA packaged heat pump holds the entire system in a single outdoor cabinet: scroll compressor, outdoor coil, indoor coil, condenser fan and supply blower. Nothing is installed in the mezzanine itself, which preserves the clear height and the work space. The unit connects to the supply and return ducts of the offices; it cools in summer, heats in winter with the heat pump, and a field-installed electric heat kit tops up the heat output in deep cold. Everything runs on electricity, at the voltage already distributed in the building.\u003c\/p\u003e\n\u003ch3\u003eFull-length base rails: a predictable lift\u003c\/h3\u003e\n\u003cp\u003eThe unit is assembled on permanently fastened full-length \u003cstrong\u003ebase rails\u003c\/strong\u003e, which form a rigid footing and protect it during transport. At grade, a forklift can pick it up from three sides; to raise it onto the roof, the lifting holes at the four corners allow a crane lift. The unit can sit on a roof curb, on steel beams above a finished roof or on a pad at grade.\u003c\/p\u003e\n\u003cp\u003eThe operating weight of the base unit is 616 lb (621 lb shipping). YORK lists 50 lb more in operation for the economizer and up to 28 lb for an electric heat kit. For the engineer checking the structure, the technical guide also publishes the load distribution:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSupport point (YORK diagram)\u003c\/th\u003e\n\u003cth\u003eA\u003c\/th\u003e\n\u003cth\u003eB\u003c\/th\u003e\n\u003cth\u003eC\u003c\/th\u003e\n\u003cth\u003eD\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad on 4-point support (lb)\u003c\/td\u003e\n\u003ctd\u003e135\u003c\/td\u003e\n\u003ctd\u003e117\u003c\/td\u003e\n\u003ctd\u003e169\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe centre of gravity sits at 38.2 in. (X) and 18.4 in. (Y) against the marks on the YORK diagram, a useful figure for setting the slings before the lift.\u003c\/p\u003e\n\u003ch3\u003eFrom below or from the back: the connections\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDucts:\u003c\/strong\u003e every model, including those with an economizer, connects from below (by removing the base panels) or horizontally, at the back. The bottom connection passes through the roof curb; the horizontal connection suits a unit set at grade, beside the wall.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e the supply wiring enters through a 2 in. knockout, on the side or from below, at a single factory-provided location, which limits roof penetrations. The control wiring has its own separate 7\/8 in. openings.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir relief:\u003c\/strong\u003e with bottom ducts, the barometric relief damper offered as an accessory mounts on the return panel opening; with horizontal ducts, it mounts on the return duct. Powered exhaust, for its part, is only possible with a bottom connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCondensate:\u003c\/strong\u003e the drain fitting is a 3\/4 in. female PVC fitting; an optional bottom drain connection routes it inside the roof curb to reduce the risk of freezing in winter.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 72 in. clear above the unit for the condenser air discharge, 24 in. on the outdoor coil side, plus the filter and economizer access clearances given by YORK.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications of the WN048C00B5CAACA1A1 model\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated capacity: 4 tons (48,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eNet AHRI cooling: 47,000 BTU\/h, EER2 of 11.2\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 44,000 BTU\/h, COP of 3.0\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 26,000 BTU\/h, COP of 2.05\u003c\/li\u003e\n\u003cli\u003eSeasonal ratings: 13.4 SEER2 and 6.7 HSPF2 (or 14.0 SEER and 8.0 HSPF under the former rating system)\u003c\/li\u003e\n\u003cli\u003eRated airflow: 1,450 CFM\u003c\/li\u003e\n\u003cli\u003ePower supply: 575 V three-phase, 60 Hz (applied voltage from 540 to 630 V)\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 44.88 x 82.25 x 32.63 in.\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B, an A2L with a low global warming potential\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e575 V: what your electrician plans for\u003c\/h3\u003e\n\u003cp\u003eAccording to the YORK electrical tables, this model calls for a minimum circuit ampacity (MCA) of 10.3 A and a fuse of no more than 15 A without electric heat. At 575 V, the backup heat kits offered for this size are the E10, E15 and E20; with the E20 kit, which works in two stages, the MCA reaches 35.8 A and the maximum fuse 40 A. The disconnect, supplied on site, mounts at the location provided on the cabinet.\u003c\/p\u003e\n\u003ch3\u003eA complete factory configuration\u003c\/h3\u003e\n\u003cp\u003eAt 575 V, we offer this size in a single factory configuration, the WN048C00B5CAACA1A1, already well equipped: \u003cstrong\u003eeconomizer\u003c\/strong\u003e without a barometric relief damper, Smart Equipment control with a BACnet MS\/TP, Modbus or N2 communication card, RDS refrigerant detector, belt-drive supply blower (standard static pressure), standard coils and 1 in. disposable filters. When the outdoor air is cool enough, the economizer can bring in up to 100% outdoor air and cool the offices without the compressor. During the estimate, we confirm with you that this package meets your needs.\u003c\/p\u003e\n\u003cp\u003eOn site, the LCD screen of the Smart Equipment control shows the supply, return and outdoor air temperatures as well as the fault codes, and our technicians pull the alarm history through the USB port. The built-in low-ambient control also allows cooling down to 0 °F (-17.8 °C) outdoors, handy for offices next to equipment that gives off heat.\u003c\/p\u003e\n\u003ch3\u003eThe steps of a crane-lift project\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSite visit, survey of the location and verification of the structure with your engineer if needed.\u003c\/li\u003e\n\u003cli\u003ePreparation of the 8 in. or 14 in. YORK roof curb, with its gasket and nailing strip, or of the steel beams.\u003c\/li\u003e\n\u003cli\u003eCrane lift using the lifting holes in the rails, then setting the unit on the curb.\u003c\/li\u003e\n\u003cli\u003eConnection of the ducts, the 575 V supply, the control wiring and the condensate drain.\u003c\/li\u003e\n\u003cli\u003eCommissioning: setting the airflow with the adjustable-pitch pulley, setting the economizer and the fan delays, and testing the electric heat kit.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eAirGreen coordinates the lift, the connections and the commissioning\u003c\/h2\u003e\n\u003cp\u003eFirst step: a free on-site estimate, during which we assess crane access, the structure, the 575 V electrical distribution and the loads of your offices. Our teams then carry out the complete installation and handle the maintenance of the unit season after season.\u003c\/p\u003e\n\u003cp\u003eFor mezzanine offices in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, AirGreen inc. is with you from the survey through to maintenance. Call 514 316-2973 or use the form on airgreen.ca: a detailed quote follows quickly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367121891620,"sku":"WN048C00B5CAACA1A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUNLINE_WN_XN_00_PRINCIPALE_04b4520d-b044-4c3a-9dba-11ba2f408bf1.png?v=1790963652"},{"product_id":"thermopompe-monobloc-york-wn-de-5-tonnes-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WN 5 Ton | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eFive tons for the ground-floor business, with no three-phase service\u003c\/h2\u003e\n\u003cp\u003eThe mixed-use building is part of the landscape in our neighbourhoods: a grocery store, a shop, a café or a clinic on the ground floor, apartments upstairs. The commercial space is often large, well glazed and busy, while the building has only a single-phase supply. This 5 ton YORK WN \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e answers exactly that case: full commercial capacity on \u003cstrong\u003e208\/230 V single-phase\u003c\/strong\u003e, with no request for three-phase service. AirGreen offers it to building owners and business owners in Montreal, Laval, Longueuil, the North Shore and the South Shore, from the estimate through to maintenance.\u003c\/p\u003e\n\u003ch3\u003eThe particular challenge of a mixed-use building\u003c\/h3\u003e\n\u003cp\u003eA large commercial space calls for a commercial-grade unit, while the electrical service of the building was designed for apartments. The KE\/WN series is offered in 208\/230-1-60 for the 3 to 5 ton sizes, which makes it possible to go up to 5 tons without redoing the electrical service in three-phase. What remains is to choose the location of the unit carefully, to check the capacity of the panel and to size the backup heat: that is where our assessment makes the difference.\u003c\/p\u003e\n\u003ch3\u003eWhere to install the unit when there are apartments above\u003c\/h3\u003e\n\u003cp\u003eSetting the unit on the main roof would mean running the ducts down through the apartments. In a mixed-use building, other locations are often simpler:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn the roof of an annex\u003c\/strong\u003e or of a single-storey addition at the back, with ducts that drop straight into the commercial space.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAt ground level, on a pad\u003c\/strong\u003e, in the yard or along the lane, with horizontal ducts that go through the back wall. Every model connects from below or horizontally.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn steel beams\u003c\/strong\u003e above a finished roof, when the structure and the access call for it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHaving apartments right next door also means taking noise into account. For this size, YORK publishes an outdoor sound rating of 88 dB(A) in cooling and 86 dB(A) in heating, to the AHRI 270 standard. The outdoor fan, two-speed on the 5 ton model, discharges vertically. We place the unit away from bedroom windows and balconies, keeping 72 in. clear above it for the condenser air discharge.\u003c\/p\u003e\n\u003ch3\u003eA complete unit in a single cabinet\u003c\/h3\u003e\n\u003cp\u003eThe packaged heat pump brings together the scroll compressor, the indoor and outdoor coils, the supply blower and the condenser fan in a galvanized steel cabinet, protected by a powder paint proven in a 750-hour salt spray test. No equipment takes up the stockroom or the ceiling of the business: the unit simply connects to the supply and return ducts. It arrives charged with refrigerant, wired, piped and tested at the factory.\u003c\/p\u003e\n\u003ch3\u003eTechnical specifications of the WN060C00B1AAACA1A1\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eMode\u003c\/th\u003e\n\u003cth\u003eCapacity\u003c\/th\u003e\n\u003cth\u003ePerformance\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e56,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003eEER2 of 10.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e52,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003eCOP of 3.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e31,800 BTU\/h\u003c\/td\u003e\n\u003ctd\u003eCOP of 2.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\n\u003cli\u003eRated capacity: 5 tons (60,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eSeasonal efficiency: 13.4 SEER2 and 6.7 HSPF2 (14.0 SEER and 8.0 HSPF, as published by YORK)\u003c\/li\u003e\n\u003cli\u003eRated airflow: 1,900 CFM\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V single-phase, 60 Hz (applied voltage from 187 to 252 V)\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 44.88 x 82.25 x 32.63 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 620 lb\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B, an A2L with a low global warming potential, with a refrigerant detection system (RDS)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe electrical picture on single-phase\u003c\/h3\u003e\n\u003cp\u003eAccording to the YORK electrical tables, this model (standard belt-drive blower, without a powered convenience outlet) calls for a minimum circuit ampacity (MCA) of 50.8 A and a fuse or breaker of no more than 70 A, without electric heat. On single-phase, the backup heat kits run from E05 to E30. The E30 kit, which works in two stages, delivers 22.2 kW at 208 V and 29.6 kW at 230 V; with it, the MCA reaches 184.2 A at 208 V and 204.9 A at 230 V. Those currents weigh heavily on a single-phase service: before choosing a kit, we go through the load calculation of the space with your master electrician. With electric heat, a minimum airflow of 1,500 CFM is required.\u003c\/p\u003e\n\u003cp\u003eThe heating capacity of the heat pump drops with the outdoor temperature, from 52,000 BTU\/h at 47 °F to 31,800 BTU\/h at 17 °F. The right kit is therefore the one that covers the real heat loss of the space in deep cold, without overloading the electrical service.\u003c\/p\u003e\n\u003ch3\u003eThe configuration we supply\u003c\/h3\u003e\n\u003cp\u003eOn single-phase, we offer this 5 ton unit in a single factory configuration, the WN060C00B1AAACA1A1. It includes the BACnet MS\/TP, Modbus or N2 communication card and the RDS refrigerant detector, with a belt-drive supply blower (standard static pressure), standard coils and 1 in. disposable filters; it has no economizer. Control works with a conventional thermostat wired to the screw terminal block; the communication card stays available if the building ever gets a management system. An economizer can also be added in the field. We confirm the right configuration during the estimate.\u003c\/p\u003e\n\u003ch3\u003eA roof curb that follows the changes in your tenants\u003c\/h3\u003e\n\u003cp\u003eIn a mixed-use building, the ground-floor business sometimes changes purpose: a shop can give way to an office, a café to a clinic. All the WN models from 3 to 5 tons share the same cabinet, the same footprint and therefore the same roof curb. If a future tenant has different needs, another size in the series installs in the same spot, on the same curb and with the same duct openings.\u003c\/p\u003e\n\u003ch3\u003eLiving on good terms with the tenants\u003c\/h3\u003e\n\u003cp\u003eAll maintenance is done at the unit, outdoors, without going into the apartments. Supply air, return air and outdoor air sensors are installed at the factory; the LCD screen shows these temperatures and the fault codes, and the board keeps the last five alarms, which our technicians also pull through the USB port. Low ambient control makes it possible to cool down to 0 °F (-17.8 °C) outdoor, useful for a business that builds up heat even out of season. The anti-short-cycle delay, the high and low pressure switches and the freeze protections protect the compressor. YORK also offers optional smoke detectors that shut the unit down if smoke is detected in the air compartment, an option we go over with you for an occupied building.\u003c\/p\u003e\n\u003ch2\u003eAirGreen takes care of your mixed-use building, from the estimate to maintenance\u003c\/h2\u003e\n\u003cp\u003eDuring the free on-site estimate, we choose the location of the unit with you, check the single-phase electrical service, calculate the loads of the space and plan the duct routing. Our crews carry out the installation, the commissioning and the seasonal maintenance.\u003c\/p\u003e\n\u003cp\u003eBuilding owners and business owners in Montreal, Laval, Longueuil, the North Shore and the South Shore: book your free on-site estimate at 514 316-2973 or through the form on airgreen.ca. Our team will get back to you quickly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367199682852,"sku":"WN060C00B1AAACA1A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUNLINE_WN_XN_00_PRINCIPALE_40067f7e-2f04-4894-9a96-ac274b2b2239.png?v=1790963457"},{"product_id":"thermopompe-monobloc-york-wn-de-5-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WN 5 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eA full dining room, a busy kitchen: 5 tons and 1,900 CFM to keep up\u003c\/h2\u003e\n\u003cp\u003eA restaurant at lunchtime, a shop on a Saturday sale day, a showroom where customers come one after the other: in these businesses, occupancy drives the temperature and the humidity up quickly. This 5 ton YORK WN packaged heat pump, powered in \u003cstrong\u003e208\/230 V three-phase\u003c\/strong\u003e, moves 1,900 CFM and delivers 56,000 BTU\/h of net cooling. With the versions fitted with an \u003cstrong\u003eeconomizer\u003c\/strong\u003e, it also takes advantage of the cool spring and fall air to cool without the compressor. AirGreen installs it in the restaurants and the businesses of Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eAll the equipment on the roof, nothing in the dining room\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e gathers the scroll compressor, the coils, the condenser fan and the supply fan into a single outdoor cabinet. Installed on the roof of the business, it connects to the supply and return ducts of the dining room, from below or horizontally. No furnace and no coil takes up the stockroom, the kitchen or the dropped ceiling, and our technicians do the maintenance on the roof, without interrupting service. In winter, the same unit heats in heat pump mode, with an electric backup kit installed in the field.\u003c\/p\u003e\n\u003ch3\u003eSensible heat and latent heat: why a packed room is demanding\u003c\/h3\u003e\n\u003cp\u003eEvery customer gives off heat, but also moisture. In a restaurant, the cooking, the dishwasher and the doors opening non-stop add even more water vapour. This moisture makes up the \u003cstrong\u003elatent load:\u003c\/strong\u003e if the unit does not remove it, the room stays clammy even when the thermostat reads the right temperature. The indoor coil on this model has four rows, with a face area of 5.06 ft², 13 fins per inch and a thermostatic expansion valve: a coil built to cool and dehumidify the air that passes through it.\u003c\/p\u003e\n\u003cp\u003eYORK publishes detailed tables of total capacity and sensible capacity according to airflow and indoor conditions. We use them to set the belt-driven fan, thanks to its adjustable-pitch motor sheave, to the airflow that suits your room: a well-chosen airflow balances the cooling of the air and the removal of moisture. This is a setting we make at commissioning, with readings to back it up, using the fan performance measurement ports located on the outside of the cabinet.\u003c\/p\u003e\n\u003ch3\u003eThe economizer, for free cooling in mid-season\u003c\/h3\u003e\n\u003cp\u003eEven in April or October, a full room and a kitchen in operation often call for cooling. The economizer then opens the outdoor air dampers, up to 100%, while the return dampers close, and lets the cool air do the compressor's work. Running the economizer and the compressor at the same time is also possible when outdoor air alone is not enough. The switch from one mode to the other is set by the outdoor dry bulb temperature; single or dual enthalpy kits, installed in the field, make it possible to account for the humidity of the outdoor air, an advantage for a room where the latent load is high.\u003c\/p\u003e\n\u003cp\u003eThe model shown on this page does not have one. YORK builds two other three-phase versions of this size at the factory:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eEconomizer\u003c\/th\u003e\n\u003cth\u003eFactory disconnect\u003c\/th\u003e\n\u003cth\u003eBACnet \/ Modbus \/ N2 card\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWN060C00B2AAACA1A1 (shown here)\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWN060C00B2CAACA1A1\u003c\/td\u003e\n\u003ctd\u003eYes, without barometric relief damper\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWN060C00B2CBACA1A1\u003c\/td\u003e\n\u003ctd\u003eYes, without barometric relief damper\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAll three include a belt-driven fan (standard static pressure), the RDS refrigerant detector, standard coils and 1 in. disposable filters. The final choice is made with you: AirGreen confirms the best-suited configuration during the estimate. If you choose the economizer, we also plan for the relief of the excess air: barometric relief damper or power exhaust, the latter requiring the ducts to be connected from below. YORK points out that with 100% outdoor air, the pressure drop across the economizer increases, and that if the return duct resistance is below 0.25 in. of water column, the unit delivers less airflow in full economizer mode; we take this into account when we size the ducts.\u003c\/p\u003e\n\u003ch3\u003eThe key numbers for the WN060C00B2AAACA1A1\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated capacity: 5 tons (60,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 56,000 BTU\/h, EER2 of 10.2\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 52,000 BTU\/h, COP of 3.35\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 31,800 BTU\/h, COP of 2.2\u003c\/li\u003e\n\u003cli\u003eSeasonal efficiency: 13.4 SEER2 and 6.7 HSPF2, which is 14.0 SEER and 8.0 HSPF under the published rating\u003c\/li\u003e\n\u003cli\u003eRated airflow: 1,900 CFM\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 44.88 x 82.25 x 32.63 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 620 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270): 88 dB(A) in cooling\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B, A2L with a low global warming potential\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThree-phase supply and heat on winter mornings\u003c\/h3\u003e\n\u003cp\u003eAccording to the YORK electrical tables, this model calls for a minimum circuit ampacity (MCA) of 29.1 A and a fuse or a breaker of no more than 40 A without electric heat. The backup kits run from E05 to E30; with the E30 kit, the MCA reaches 106.1 A at 208 V and 118.1 A at 230 V. In the morning, before opening, the heat pump delivers 52,000 BTU\/h at 47 °F and 31,800 BTU\/h at 17 °F, and the electric kit tops up the heat in deep cold. The electric heat requires a minimum airflow of 1,500 CFM.\u003c\/p\u003e\n\u003ch3\u003eInstallation tips for a busy business\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof curb:\u003c\/strong\u003e YORK offers curbs 8 in. and 14 in. high, shipped knocked down; the unit's rails frame the curb, which makes a watertight joint with the finished roof.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifting:\u003c\/strong\u003e the full-length base rails have lifting holes for the crane and accept a forklift on three sides.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilters:\u003c\/strong\u003e two 15 x 20 in. filters and one 14 x 25 in. filter, 1 in. or 2 in. thick; a dirty filter switch, offered as an option, reports an abnormal pressure drop to the thermostat.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof:\u003c\/strong\u003e the electrical supply enters at a single point, from the side or from below, which limits the penetrations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eA control that takes the rush in stride\u003c\/h3\u003e\n\u003cp\u003eThe Smart Equipment control applies a short-cycle delay and minimum run times, watches every pressure switch and every freeze protection, and keeps the last five alarms. The communication card installed at the factory makes it possible to link the unit to a management system on BACnet MS\/TP, Modbus or N2, handy for a chain that follows several locations.\u003c\/p\u003e\n\u003ch2\u003eYour restaurant or your business, in AirGreen's hands\u003c\/h2\u003e\n\u003cp\u003eOur free on-site estimate includes the roof survey, the calculation of the sensible and latent loads according to your traffic, the check of the three-phase supply and the choice between the three factory configurations. We schedule the installation outside your opening hours when that is possible, then we take care of the commissioning and the maintenance.\u003c\/p\u003e\n\u003cp\u003eRestaurant owners and retailers of Montreal, Laval, Longueuil, the North Shore and the South Shore: call AirGreen at 514\u0026nbsp;316-2973 or fill out the form on airgreen.ca. We will get back to you quickly to set the visit at the time that disturbs your service the least.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367199715620,"sku":"WN060C00B2AAACA1A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUNLINE_WN_XN_00_PRINCIPALE_8992f8a8-2b2c-4aa4-bfb7-9168ad55910a.png?v=1790963438"},{"product_id":"thermopompe-monobloc-york-wn-de-5-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WN 5 Ton 575V | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eReplacing an end-of-life rooftop unit on a building fed at 575 V\u003c\/h2\u003e\n\u003cp\u003eOn many commercial and industrial buildings, the original rooftop unit reaches the end of its service life: repeat repairs, parts that are hard to find, uneven comfort. If your building is fed at \u003cstrong\u003e575 V three-phase\u003c\/strong\u003e, this 5-ton YORK WN \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e connects directly to that voltage, with no transformer, and arrives with an economizer already installed at the factory. AirGreen takes on the whole replacement, from the roof survey through to commissioning, in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\u003ch3\u003eBefore the replacement: the survey we carry out\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe dimensions and the condition of the existing roof curb, as well as the position of the supply and return openings.\u003c\/li\u003e\n\u003cli\u003eThe 575 V supply, the disconnect and the run of the wiring to the unit.\u003c\/li\u003e\n\u003cli\u003eThe structure and the crane access, including the room to manoeuvre at grade.\u003c\/li\u003e\n\u003cli\u003eThe clear space around the location, including the 72 in. required above the unit to discharge the condenser air.\u003c\/li\u003e\n\u003cli\u003eThe heating and cooling loads of the rooms served, to confirm that 5 tons is the right size.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOne common roof curb from 3 to 5 tons\u003c\/h3\u003e\n\u003cp\u003eIn the KE\/WN series, every model and every configuration shares the same cabinet, the same footprint and therefore the same \u003cstrong\u003eroof curb\u003c\/strong\u003e. YORK points out the benefit: you can install a curb, then choose the capacity and the heating mode once the indoor loads are settled. For your building, that means a future change to the rooms will be made on the same curb, with a 3, 4 or 5 ton model.\u003c\/p\u003e\n\u003cp\u003eA curb designed for another manufacturer or another generation of unit does not necessarily have the same dimensions. During the survey, we compare the existing curb against the YORK template. If needed, we install an 8 in. or 14 in. YORK curb: built to NRCA requirements, these curbs ship knocked down, nest inside the unit's base rails and include a nailing strip and duct supports; a gasket goes on the curb frame and on every duct bearing surface.\u003c\/p\u003e\n\u003ch3\u003eA complete heat pump in the same footprint\u003c\/h3\u003e\n\u003cp\u003eLike the old unit, the WN is a packaged unit: scroll compressor, indoor and outdoor coils, supply blower and condenser fan all sit in a single cabinet set on the roof and tied into the existing ducts. What sets it apart: it works as a heat pump, cools in summer and heats in winter by reversing its cycle, and a field-installed electric heat kit tops up the heat output during deep cold. The connections are made from below, through the roof curb, or horizontally, which makes it easier to adapt to the duct system already in place.\u003c\/p\u003e\n\u003ch3\u003eTechnical data for the WN060C00B5CAACA1A1\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated capacity: 5 tons (60,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eNet AHRI cooling: 56,000 BTU\/h, EER2 of 10.2\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 52,000 BTU\/h, COP of 3.35\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 31,800 BTU\/h, COP of 2.2\u003c\/li\u003e\n\u003cli\u003ePublished seasonal efficiency: 13.4 SEER2 \/ 6.7 HSPF2, that is 14.0 SEER \/ 8.0 HSPF\u003c\/li\u003e\n\u003cli\u003eRated airflow: 1,900 CFM\u003c\/li\u003e\n\u003cli\u003ePower supply: 575 V three-phase, 60 Hz (applied voltage from 540 to 630 V)\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 44.88 x 82.25 x 32.63 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 620 lb (625 lb shipping), without the economizer, which adds 50 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270): 88 dB(A) in cooling, 86 dB(A) in heating\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B, an A2L with a low global warming potential\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe model offered, the WN060C00B5CAACA1A1, is the only 575 V configuration we carry in this size. It arrives from the factory with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ean economizer without a barometric relief damper, ready to bring in up to 100% outdoor air;\u003c\/li\u003e\n\u003cli\u003ethe BACnet MS\/TP communication card, programmable for Modbus or N2;\u003c\/li\u003e\n\u003cli\u003ethe RDS refrigerant detector;\u003c\/li\u003e\n\u003cli\u003ea belt-drive supply blower, at standard static pressure;\u003c\/li\u003e\n\u003cli\u003euncoated coils and 1 in. disposable filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAt the estimate, we confirm with you that this equipment matches your building.\u003c\/p\u003e\n\u003ch3\u003eThe lift, step by step\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnection and removal of the old unit, then inspection of the curb and of the weather seal.\u003c\/li\u003e\n\u003cli\u003ePreparation of the curb: new gasket or new YORK curb depending on the survey.\u003c\/li\u003e\n\u003cli\u003eCrane lift of the new unit, using the lifting holes at the four corners of the full-length base rails.\u003c\/li\u003e\n\u003cli\u003e575 V electrical connection (entry on the side or from below), control wiring, ducts and condensate drain.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eThe 575 V connection\u003c\/h3\u003e\n\u003cp\u003eAccording to the YORK electrical tables, this model calls for a minimum circuit ampacity (MCA) of 11.9 A and a fuse of no more than 15 A without electric heat. At 575 V, the backup kits offered are the E10, E15, E20 and E30; those of 20 kW and up work in two stages. With the E30 kit, the MCA reaches 48.5 A and the maximum fuse 50 A. A minimum airflow of 1,500 CFM is required with electric heat.\u003c\/p\u003e\n\u003ch3\u003eCommissioning by our technicians\u003c\/h3\u003e\n\u003cp\u003eEvery unit is configured and tested at the factory, but it is the on-site commissioning that adapts it to your building. Here is what our technicians check and set:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eThe measured voltage, within the 540 to 630 V range allowed by YORK.\u003c\/li\u003e\n\u003cli\u003eThe removal of the factory-installed R-OCC jumper, so that the thermostat or the management system commands occupied mode.\u003c\/li\u003e\n\u003cli\u003eThe airflow, measured at the ports on the outside of the cabinet and adjusted with the adjustable-pitch drive pulley.\u003c\/li\u003e\n\u003cli\u003eThe economizer set point, the fan delays and the minimum run times of the compressor.\u003c\/li\u003e\n\u003cli\u003eThe operation of the electric heat kit, of its stages and of its limit switch.\u003c\/li\u003e\n\u003cli\u003eThe start-up report, pulled through the USB port of the Smart Equipment control, which we keep in your file.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eDiagnostics that simplify maintenance in the years ahead\u003c\/h3\u003e\n\u003cp\u003eAfter years of repairs on the old unit, the \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control changes the way maintenance is done. Every alarm flashes a code on the LCD screen and lights the fault indicator on the thermostat, if it has one. The board keeps the last five alarms in memory, even after a power failure, and the USB port gives access to the data logging and the fault history. The \"three times, then stop\" logic keeps a one-off trip of a pressure switch or of a freeze protection from locking out the compressor, which cuts down on needless service calls.\u003c\/p\u003e\n\u003ch2\u003eA turnkey replacement, entrusted to AirGreen\u003c\/h2\u003e\n\u003cp\u003eOur free on-site estimate covers the survey of the existing curb, of the 575 V supply and of the crane access, along with the load calculations. Our teams then coordinate the removal of the old unit, the lift, the connections, the commissioning and the maintenance in the years that follow.\u003c\/p\u003e\n\u003cp\u003eManagers and owners of 575 V buildings in Montreal, Laval, Longueuil, on the North Shore and on the South Shore: contact AirGreen inc. at 514 316-2973 or through the form on airgreen.ca to plan the replacement. We get back to you quickly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367201288484,"sku":"WN060C00B5CAACA1A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUNLINE_WN_XN_00_PRINCIPALE_adb59bd4-e6a0-49d8-9f57-63c1c399f74f.png?v=1790963415"},{"product_id":"thermopompe-monobloc-york-wqe-de-3-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WQE 3 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eReplacing a 3 ton rooftop unit by making the most of the existing roof curb\u003c\/h2\u003e\n\u003cp\u003eWhen the 3 ton rooftop unit of a store, an office or a service space reaches the end of its service life, the most direct plan is to remove the old unit, check the roof curb and the ducts already in place, then set a new unit down in the same spot. The \u003cstrong\u003eYORK Sun Core\u003c\/strong\u003e cabinet was designed with the replacement market in mind: its full-perimeter base rail fits many existing roof curbs. At AirGreen, we plan this kind of replacement for businesses in Montreal, Laval, Longueuil, the North Shore and the South Shore, from the first site visit through to commissioning.\u003c\/p\u003e\n\u003cp\u003eThe WQE04A2C1AB5A111A1 model is a 208\/230 V three-phase 3 ton (36,000 BTU\/h nominal) \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e from the WQE series, the standard-efficiency version of the Sun Core line. It runs on R-454B refrigerant and takes, according to your needs, a field-installed electric heat kit.\u003c\/p\u003e\n\u003ch3\u003eA complete unit, set down on the roof curb\u003c\/h3\u003e\n\u003cp\u003eA packaged heat pump gathers the whole system in a single outdoor cabinet: compressor, outdoor coil, indoor coil, supply fan, filters and control. It is installed on the roof or at ground level and connects directly to the building's supply and return \u003cstrong\u003educts\u003c\/strong\u003e. On a replacement, nothing is added indoors: the work stays on the roof, then moves to the thermostat or zone sensor connection. In summer, the unit cools; in winter, the heat pump heats the space and the electric kit supplies backup heat when needed.\u003c\/p\u003e\n\u003ch3\u003eA full-perimeter base rail built for replacement\u003c\/h3\u003e\n\u003cp\u003eThe base rail runs around the entire perimeter of the cabinet. YORK builds it in a heavier gauge, with a shape worked out to avoid damage during transport and lifting; it has holes for the lifting shackles and for moving the unit with a forklift. Since no two roof curbs are ever exactly alike, we always measure yours before confirming compatibility.\u003c\/p\u003e\n\u003cp\u003eIf the existing curb does not work out, YORK offers two rigid roof curbs for its small cabinet size: the 14 in. 1RC0456 and the 24 in. 1RC0458, with an insulated deck and shipped unassembled. These same curbs serve the 3, 4 and 5 ton models (WQE04, WQE05, WQE06 and their WYE equivalents). That leaves you the option of moving up to a larger capacity later without rebuilding the curb.\u003c\/p\u003e\n\u003ch3\u003eModel specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal capacity: 3 tons (36,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 35,600 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 34,500 BTU\/h, COP of 3.5\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 19,500 BTU\/h, COP of 2.1\u003c\/li\u003e\n\u003cli\u003eEfficiency: 14.0 SEER2, 6.7 HSPF2 and 12.2 EER2\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 1,240 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V three-phase, 60 Hz (allowable applied voltage from 187 V to 252 V)\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 48.9 x 74.1 x 32.5 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 529 lb (542 lb shipping)\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level per AHRI 270: 78.4 dBA\u003c\/li\u003e\n\u003cli\u003eR-454B refrigerant, one scroll compressor on a single refrigeration circuit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eA short cabinet and a high static pressure blower\u003c\/h3\u003e\n\u003cp\u003eAt 32.5 in. tall, the 3 ton model uses the short cabinet of the small Sun Core size, while the 4 and 5 ton models reach 40.6 in. According to the YORK nomenclature, the letter C in the model number designates the high static pressure option: a belt-driven centrifugal blower, a 2.4 HP motor and an adjustable-pitch drive pulley. It is a sound choice when the existing duct system is long or includes several elbows, since the YORK tables cover up to 2.0 in. w.c. of available external static pressure. Before start-up, we measure the actual static pressure of your ducts and adjust the pulley to reach the target airflow.\u003c\/p\u003e\n\u003ch3\u003eWhat you gain over the old unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-454B refrigerant:\u003c\/strong\u003e an A2L refrigerant with a low global warming potential. According to the YORK nomenclature, this model includes the refrigerant detection system (RDS), which starts a dilution sequence and an alarm when it detects a leak equal to 25% of the lower flammability limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Equipment control:\u003c\/strong\u003e built-in LCD display, USB port, factory-installed temperature sensors, voltage monitoring and compressor lockout after three trips of the same safety within two hours.\u003c\/li\u003e\n\u003cli\u003eCommunication with a building management system: the model code provides for the BACnet MS\/TP, Modbus and N2 communication card.\u003c\/li\u003e\n\u003cli\u003eScroll compressor with internal protection, liquid line filter drier and high and low pressure switches.\u003c\/li\u003e\n\u003cli\u003eCoils with copper tubes and aluminum fins, embossed top for rigidity and powder paint rated 750 hours of salt spray.\u003c\/li\u003e\n\u003cli\u003e2 in. filters (two 16 x 25 x 2 in. filters, MERV 4 from the factory), reachable without tools through a dedicated panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical and backup heat: to confirm before the quote\u003c\/h3\u003e\n\u003cp\u003eThe existing circuit can be reused if its rating is adequate. Without backup heat, the YORK guide gives for this configuration a minimum circuit ampacity (MCA) of 22.5 A at 208 V and 22.8 A at 230 V, with a fuse or a breaker of 30 A maximum. Adding an electric heat kit changes these values. In 208\/230 V three-phase, the small size kits come in 6.5, 10.5 and 16 kW at 230 V, which gives 4.9, 7.9 and 12 kW when the actual supply is 208 V. We therefore measure the voltage at your electrical service before choosing the kit and the circuit rating; the unit's nameplate always has the last word.\u003c\/p\u003e\n\u003ch3\u003eHow a typical replacement unfolds\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVisit to your space: survey of the roof curb, the duct openings and the electrical service.\u003c\/li\u003e\n\u003cli\u003eLoad calculation to confirm that 3 tons still suit the current use of the space.\u003c\/li\u003e\n\u003cli\u003eOrder of the unit and, if needed, of a new roof curb, a heat kit, an economizer or a hail guard (kit 1HG0419, specific to the short cabinet).\u003c\/li\u003e\n\u003cli\u003eCrane lift: the unit weighs 542 lb as shipped and its rails are meant for lifting with shackles.\u003c\/li\u003e\n\u003cli\u003eRespect of the YORK clearances: 72 in. above, 36 in. at the front, 18 in. at the back (36 in. with an economizer or a powered exhaust), 18 in. on the right and 12 in. on the left.\u003c\/li\u003e\n\u003cli\u003eConnections, airflow adjustment, commissioning and a start-up report pulled from the control's USB port.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eEvery unit leaves the factory configured and run-tested, which simplifies commissioning on the roof. The control also allows cooling down to 40 °F (4 °C) outdoors with no additional component.\u003c\/p\u003e\n\u003ch2\u003eTrust AirGreen with your 3 ton replacement\u003c\/h2\u003e\n\u003cp\u003eWe sell and install YORK Sun Core packaged heat pumps, and our crews take charge of the whole project: free on-site estimate, sizing, lift coordination, duct and electrical connections, commissioning and maintenance. As an \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor based in Montreal, we also handle coordination with your building manager or your general contractor.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA single crew in charge, from the site visit to the first start-up\u003c\/li\u003e\n\u003cli\u003eWork planned around your business hours and carried out quickly\u003c\/li\u003e\n\u003cli\u003eRegular maintenance: filter changes, coil cleaning and belt inspection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhether your business is in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, we hand you a clear quote after our visit. To book your free on-site estimate, call us at 514 316-2973 or fill out the form on airgreen.ca: we get back to you quickly to set the date of the visit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367201354020,"sku":"WQE04A2C1AB5A111A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_5a3515be-5bc4-4bfd-ab0f-17ece8154ebb.png?v=1790963397"},{"product_id":"thermopompe-monobloc-york-wqe-de-4-tonnes-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WQE 4 Ton | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eFour tons of comfort for your business, without three-phase service\u003c\/h2\u003e\n\u003cp\u003eA hair salon, a small grocery, a professional office or a ground-floor space in a mixed-use building: plenty of businesses have only a single-phase electrical service. Having three-phase service brought in for a single rooftop unit can call for major electrical work. The WQE05A1B1AB5A111A1 model avoids that detour: this 4 ton YORK Sun Core \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e (48,000 BTU\/h nominal) runs on 208\/230 V single-phase, 60 Hz. AirGreen sells, installs and maintains it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\u003cp\u003eIn the Sun Core lineup, single-phase power is reserved for the 3 to 5 ton models. The WQE series is the standard-efficiency version, with R-454B refrigerant, without factory-installed heat: an electric kit is added in the field according to your needs.\u003c\/p\u003e\n\u003ch3\u003eThe packaged unit, seen from the electrical side\u003c\/h3\u003e\n\u003cp\u003eA packaged heat pump brings the entire system together in a single outdoor cabinet, set on the roof or at ground level and connected to the supply and return ducts of the space. Compressor, coils, indoor blower, filters, control and, where applicable, heating elements share the same cabinet. For your electrician, that means a single main feed to plan for, plus the low-voltage thermostat wiring. There is no separate indoor unit to power and no refrigerant piping to run through the building.\u003c\/p\u003e\n\u003ch3\u003eModel specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower supply: 208\/230 V single-phase, 60 Hz; allowable applied voltage from 187 V to 252 V\u003c\/li\u003e\n\u003cli\u003eCapacity: 4 tons, that is 48,000 BTU\/h nominal\u003c\/li\u003e\n\u003cli\u003eNet cooling per AHRI: 48,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 45,600 BTU\/h with a COP of 3.5\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 24,600 BTU\/h with a COP of 2.15\u003c\/li\u003e\n\u003cli\u003eEfficiency ratings: 14.0 SEER2, 6.7 HSPF2 and 12.2 EER2\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 1,550 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003eFootprint: 48.9 in. wide, 74.1 in. long and 40.6 in. high (48.9 x 74.1 x 40.6 in.)\u003c\/li\u003e\n\u003cli\u003eOperating weight: 628 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound rating per AHRI 270: 78.4 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese ratings are identical to those of the 4 ton three-phase version: going single-phase costs you neither capacity nor efficiency.\u003c\/p\u003e\n\u003ch3\u003eReference electrical data\u003c\/h3\u003e\n\u003cp\u003eThe YORK technical guide publishes the following values for this configuration (medium static pressure blower, without a powered convenience outlet or a powered exhaust). The scroll compressor has a rated load amperage (RLA) of 19.4 A and a locked rotor amperage (LRA) of 102 A.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003e208 V single-phase\u003c\/th\u003e\n\u003cth\u003e230 V single-phase\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithout backup heat: minimum circuit ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e33.9 A\u003c\/td\u003e\n\u003ctd\u003e33.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithout backup heat: maximum fuse or breaker size\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit 2EK04511125: heat delivered\u003c\/td\u003e\n\u003ctd\u003e7.9 kW\u003c\/td\u003e\n\u003ctd\u003e10.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit 2EK04511125: minimum circuit ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e81.4 A\u003c\/td\u003e\n\u003ctd\u003e88.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit 2EK04511125: maximum fuse or breaker size\u003c\/td\u003e\n\u003ctd\u003e90 A\u003c\/td\u003e\n\u003ctd\u003e90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese figures are used for planning; the nameplate of the unit delivered remains the reference for the final circuit sizing.\u003c\/p\u003e\n\u003ch3\u003eBackup heat: 208 V or 230 V, the difference counts\u003c\/h3\u003e\n\u003cp\u003eThe YORK 2EK04511125 kit is offered for the small cabinet in 208\/230 V, single-phase or three-phase. It is rated 10.5 kW at 230 V, but delivers only 7.9 kW when the actual voltage is 208 V. We therefore measure the available voltage before confirming your backup heat requirement. The factory non-fused disconnect comes in 60 A and in 100 A; YORK points out that it may be insufficient with certain heat kits. Above 100 A, it has to be removed and an external disconnect of the appropriate size installed.\u003c\/p\u003e\n\u003ch3\u003eA blower and a control designed for this power supply\u003c\/h3\u003e\n\u003cp\u003eThe model number carries a B in the eighth position, which corresponds, in YORK's nomenclature, to the medium static pressure blower. On this single-phase version, the belt-driven centrifugal blower gets a 1.5 HP motor fitted with an adjustable-pitch drive sheave. The high static pressure option is reserved for three-phase models; for demanding ducts, we therefore check the static pressure before confirming this choice.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control continuously monitors the voltage supplied to the unit and protects it in the event of a voltage drop or any other electrical deviation. It adds an anti-short-cycle delay, programmable minimum run times and independent fan delays in heating and in cooling. The built-in LCD screen shows the unit status, the supply, return and outdoor air temperatures as well as the fault codes. With a simple USB key, the built-in port makes it possible to retrieve current and previous faults and to update the software. The model code also provides for the BACnet MS\/TP, Modbus and N2 communication card as well as the refrigerant detection system (RDS), which monitors leaks of R-454B, an A2L refrigerant with a low global warming potential.\u003c\/p\u003e\n\u003ch3\u003eConstruction and compatible accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle scroll compressor, a single circuit, thermostatic expansion valve (TXV), filter-drier and high and low pressure switches\u003c\/li\u003e\n\u003cli\u003eCoils with copper tubes and aluminum fins; direct-drive outdoor fan, dynamically balanced\u003c\/li\u003e\n\u003cli\u003eFour 16 x 16 x 2 in. filters, MERV 4 as supplied, replaceable with MERV 8 or MERV 13 filters thanks to the tool-less access panel\u003c\/li\u003e\n\u003cli\u003eVertical or horizontal flow economizers offered for all voltages, and powered exhausts in a 208\/230 V single-phase version\u003c\/li\u003e\n\u003cli\u003eLouvered hail guard (kit 1HG0420 for the tall cabinet)\u003c\/li\u003e\n\u003cli\u003e120 V convenience outlet with ground fault circuit interrupter, as a factory option\u003c\/li\u003e\n\u003cli\u003eFull perimeter base compatible with many existing roof curbs, or YORK curbs of 14 in. and 24 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat we check before the installation\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eThe capacity of the electrical panel and of the existing single-phase service, with or without backup heat.\u003c\/li\u003e\n\u003cli\u003eThe actual voltage (208 V or 230 V), which determines the heat delivered by the electric kit.\u003c\/li\u003e\n\u003cli\u003eThe condition and the dimensions of the roof curb, as well as the duct openings from underneath or from the side.\u003c\/li\u003e\n\u003cli\u003eThe lift, the service clearances around the cabinet and the condensate drainage.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eFrom the electrical service to the start-up, AirGreen takes care of everything\u003c\/h2\u003e\n\u003cp\u003eA single-phase packaged heat pump project calls for close coordination between the capacity of the unit, the electrical circuit and the roof. Our teams carry out the free on-site estimate, the load calculation for your space, the selection of the heat kit, the complete installation and the start-up. We then stay available for the regular maintenance of your unit: filters, belt, coils and a reading of the fault log. As a Montreal \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor, we work quickly and efficiently, scheduling the work around your business hours.\u003c\/p\u003e\n\u003cp\u003eIf your business is located in Montreal, Laval, Longueuil, on the North Shore or on the South Shore and is fed in single-phase only, call us at 514 316-2973 or fill out the form on airgreen.ca to book your free on-site estimate. We will propose a 4 ton solution suited to your electrical service.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367203942692,"sku":"WQE05A1B1AB5A111A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_609494b3-fbb6-4b68-8d92-440a9902a952.png?v=1790963379"},{"product_id":"thermopompe-monobloc-york-wqe-de-4-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WQE 4 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eClear data to manage a 4 ton rooftop unit\u003c\/h2\u003e\n\u003cp\u003eWhen a tenant reports that it is too warm, a building manager wants to know quickly what is happening on the roof: whether the unit is running normally, whether a safety has tripped or whether the airflow is adequate. For that kind of follow-up, the built-in control counts as much as the capacity. That is the strength of this WQE05A2B1AB5A111A1 model: a 4 ton YORK Sun Core \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e (48,000 BTU\/h nominal), in 208\/230 V three-phase, that records and displays what it is doing. AirGreen installs and maintains it in the commercial and rental buildings of Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003cp\u003eThe WQE series is the standard-efficiency version of the Sun Core line. It runs on R-454B, an A2L refrigerant with a low global warming potential, and receives its electric backup heat in the field.\u003c\/p\u003e\n\u003ch3\u003eWhat the LCD display shows right on the unit\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control has a readable LCD display, a navigation joystick and buttons. The technician goes through the menus quickly, right on the unit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe status of the unit and the function in progress (cooling, heating, ventilation);\u003c\/li\u003e\n\u003cli\u003ethe options configured at the factory;\u003c\/li\u003e\n\u003cli\u003ethe supply air, return air and outdoor air temperatures, measured by factory-installed sensors;\u003c\/li\u003e\n\u003cli\u003ethe fault codes and other operating information.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe USB port: history, reports and updates\u003c\/h3\u003e\n\u003cp\u003eAn ordinary USB key is all it takes to make use of the port built into the control board. It gives access to the data logging, to the current and previous faults, as well as to the self-test and start-up reports. The same port is used to update the control software. YORK adds energy consumption tracking functions, which allow operation to be adjusted to the time periods and the occupancy level of the building. For you, that means better documented service visits and decisions based on facts rather than on impressions.\u003c\/p\u003e\n\u003ch3\u003eProtections that leave a trace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage monitoring:\u003c\/strong\u003e the control checks the supplied voltage and protects the unit in case of a voltage drop or another electrical anomaly.\u003c\/li\u003e\n\u003cli\u003eHigh and low pressure switches and temperatures monitored continuously, as are the high temperature limits when an electric heat kit is installed.\u003c\/li\u003e\n\u003cli\u003eThree-trip rule: the same safety has to trip three times within two hours before the compressor is locked out, which avoids service calls for an isolated trip.\u003c\/li\u003e\n\u003cli\u003eAnti-short-cycle delay and programmable minimum run times to spare the compressor, with a temporary bypass button during testing.\u003c\/li\u003e\n\u003cli\u003eProgrammable fan delays, independent in heating and in cooling.\u003c\/li\u003e\n\u003cli\u003eCooling possible down to 40 °F (4 °C) outdoors with no additional component, with the option of locking out the compressor in cold weather or when free cooling is available.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLinking the unit to your building management system\u003c\/h3\u003e\n\u003cp\u003eThe control works with a conventional thermostat wired to screw terminals, with a zone sensor, or in communication with a building management system. The YORK nomenclature confirms that this model is fitted with the BACnet MS\/TP, Modbus and N2 communication card. Your operating data can then travel up to the management station already in place, rather than staying on the roof. The code also provides for the refrigerant detection system (RDS), tied to the control, which starts a dilution sequence and an alarm in case of a leak.\u003c\/p\u003e\n\u003ch3\u003eOne cabinet, one place to watch\u003c\/h3\u003e\n\u003cp\u003eA packaged heat pump houses the whole system in an outdoor cabinet installed on the roof or at ground level: compressor, coils, fan, filters, control and backup heating elements. The building's duct system connects to it directly, on the supply as on the return. For a manager, this layout simplifies the follow-up: no indoor unit in a ceiling or a service room, and a single piece of equipment to inspect in order to understand how the system behaves.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eData\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e4 tons (48,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e45,600 BTU\/h, COP of 3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e24,600 BTU\/h, COP of 2.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2, HSPF2 and EER2\u003c\/td\u003e\n\u003ctd\u003e14.0, 6.7 and 12.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e1,550 CFM (ft³\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor blower\u003c\/td\u003e\n\u003ctd\u003eBelt drive, medium static pressure, 2.4 HP three-phase motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e208\/230 V three-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth x length x height\u003c\/td\u003e\n\u003ctd\u003e48.9 x 74.1 x 40.6 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e628 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor sound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e78.4 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField-installed backup heat\u003c\/td\u003e\n\u003ctd\u003eKits of 6.5, 10.5 or 16 kW at 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor this configuration with no backup heat, YORK publishes a minimum circuit ampacity (MCA) of 22.2 A at 208 V and 22.5 A at 230 V; the fuse or the breaker must not exceed 30 A. A heat kit drives these values up, and the nameplate remains the reference.\u003c\/p\u003e\n\u003ch3\u003eA cabinet built to last on the roof\u003c\/h3\u003e\n\u003cp\u003eThe embossed top reinforces the structure and the rigidity of the cabinet, and the powder paint is rated 750 hours of salt spray. YORK tests and rates its units to cool up to 125 °F (52 °C) outdoor temperature. Its perimeter base rail fits many existing roof curbs, which makes replacing a unit at the end of its life easier.\u003c\/p\u003e\n\u003ch3\u003eA design that makes maintenance easier\u003c\/h3\u003e\n\u003cp\u003eThe 2 in. filters (four 16 x 16 x 2 in. filters, MERV 4 from the factory) are replaced through an access panel without tools, and MERV 8 or MERV 13 filters can be installed if needed. The large access panels clear the blower and its components, while the direct-drive outdoor fan, fastened to the grille, makes quick maintenance easier. A port provided in the top panel makes it possible to read the circuit pressures without removing the compressor access panel. As a factory option, hinged doors avoid having to remove panels on the roof, and a 120 V service outlet with a ground fault circuit interrupter stays within the technician's reach. The scroll compressor, the filter drier, the thermostatic expansion valve and the copper and aluminum coils round out a proven package. YORK configures every unit and puts it through a run test at the factory.\u003c\/p\u003e\n\u003ch3\u003eOur follow-up after the installation\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eCommissioning and keeping the start-up report produced by the control.\u003c\/li\u003e\n\u003cli\u003eSetting the fan delays and the parameters to your building's schedule.\u003c\/li\u003e\n\u003cli\u003eTesting the communication with your building management system, where applicable.\u003c\/li\u003e\n\u003cli\u003eScheduled maintenance visits, with filter replacement, belt check and review of the fault history.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eInstallation, commissioning and follow-up by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen sells and installs the YORK Sun Core line. Our crews take care of the free on-site estimate, the sizing, the complete installation, the commissioning and the maintenance. An \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor from Montreal, we work with building managers and general contractors so that every job is quick, efficient and well documented.\u003c\/p\u003e\n\u003cp\u003eBuilding managers in Montreal, Laval, Longueuil, the North Shore and the South Shore: for a rooftop unit that is easy to follow, call us at 514 316-2973 or fill out the form on airgreen.ca. We will quickly set the date of your free on-site estimate.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367203975460,"sku":"WQE05A2B1AB5A111A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_a43febbe-e4b8-401a-b335-16c8f45fe547.png?v=1790963362"},{"product_id":"thermopompe-monobloc-york-wqe-de-5-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WQE 5 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eBetter filtered and better renewed air for your business or your clinic\u003c\/h2\u003e\n\u003cp\u003eIn a clinic waiting room, a boutique with fitting rooms or a busy retail store, comfort is not limited to temperature. You also have to filter the air, bring in fresh air and protect the occupants. Model WQE06A2B1AB5A111A1, a 5 ton YORK Sun Core \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e (60,000 BTU\/h nominal) on 208\/230 V three-phase, lends itself well to these uses thanks to its upgradable filtration and to the economizers and safety options offered by YORK. Our crews install it in Montreal, in Laval and in Longueuil, as well as on the North Shore and the South Shore, in businesses as much as in clinics.\u003c\/p\u003e\n\u003cp\u003ePart of the WQE series, the standard efficiency version of the Sun Core line, this unit uses R-454B, an A2L refrigerant whose global warming potential is low. Its electric backup heat is added in the field.\u003c\/p\u003e\n\u003ch3\u003eFiltration: from MERV 4 to MERV 13 in the same filter rack\u003c\/h3\u003e\n\u003cp\u003eThe unit takes four 16 x 16 x 2 in. filters. It ships with MERV 4 disposable filters, and YORK provides for adding \u003cstrong\u003eMERV 8\u003c\/strong\u003e or \u003cstrong\u003eMERV 13\u003c\/strong\u003e filters through the filter access panel, which opens without tools, in particular to meet LEED requirements. A filter with a higher MERV rating holds back more fine particles, but it adds resistance to the passage of the air: we take that into account when we set the fan. According to the YORK nomenclature, this model is equipped with the medium static pressure option, that is a belt-driven centrifugal fan with a 2.4 HP three-phase motor and an adjustable motor sheave.\u003c\/p\u003e\n\u003ch3\u003eThe economizer: outdoor air up to 100%\u003c\/h3\u003e\n\u003cp\u003eAn economizer brings in outdoor air to ventilate the space and, when conditions allow, to cool it without putting the compressor to work. For this model, the economizer is installed in the field, in vertical flow (kit 2EE04711424) or horizontal flow (kit 2EE04707124 for the tall cabinet). Here is what the YORK guide says about it:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003elow-leakage AMCA 511 class 1A dampers, that is 3 CFM per square foot at 1 in. of static pressure;\u003c\/li\u003e\n\u003cli\u003e60,000 cycle endurance test for every economizer;\u003c\/li\u003e\n\u003cli\u003edry bulb temperature control as standard, with single (2EC0401) or dual (2EC0402) enthalpy kits;\u003c\/li\u003e\n\u003cli\u003efully modulating, spring-return actuators, able to bring in up to 100% outdoor air;\u003c\/li\u003e\n\u003cli\u003efull integration with the Smart Equipment control and a power exhaust offered to go with it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor simpler ventilation, YORK also offers manual outdoor air dampers from 0 to 35% or from 0 to 100%, as well as a motorized damper from 0 to 100%. One point worth knowing at the design stage: the pressure drop across the economizer is greater at 100% outdoor air than at 100% return air, and if the return duct resistance is below 0.25 in. of water column, the unit will deliver less airflow in full economizer mode.\u003c\/p\u003e\n\u003ch3\u003eDemand ventilation and integrated control\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control includes the economizer controller. According to YORK's specifications, it accepts a CO₂ sensor in the occupied space and it is ready for demand ventilation, which allows the fresh air supply to be matched to the actual traffic in the space. It can also lock out the compressor when free cooling is available. Supply, return and outdoor air temperature sensors are installed at the factory, and the LCD screen shows these readings as well as the fault codes. According to its nomenclature, this model includes the BACnet MS\/TP, Modbus and N2 communication card; a factory configuration without this card carries the number WQE06A2B1AA5A111A1.\u003c\/p\u003e\n\u003ch3\u003eOccupant safety and protection of the unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmoke detectors:\u003c\/strong\u003e offered for the supply air, the return air or both, they cut power to the unit and send a fault message to the control when they detect smoke.\u003c\/li\u003e\n\u003cli\u003eRefrigerant detection system (RDS) included according to the nomenclature: in the event of a leak, it triggers a dilution sequence and an alarm.\u003c\/li\u003e\n\u003cli\u003eNon-fused disconnect of 60 A or 100 A as a factory option; the model shown does not include one, and we then plan for an external disconnect of the appropriate rating.\u003c\/li\u003e\n\u003cli\u003eLouvered hail guard (kit 1HG0420) to protect the outdoor coil fins.\u003c\/li\u003e\n\u003cli\u003eInternally sloped condensate pan, made of a non-corrosive material and compliant with ASHRAE 62.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe packaged unit, a single air path to manage\u003c\/h3\u003e\n\u003cp\u003eThe principle is simple: the entire unit fits in an outdoor cabinet, installed on the roof or at ground level and connected to the building's ducts. The return air is filtered, cooled or heated there, then sent back by the fan to the supply ducts. The economizer mounts on the same cabinet, as does the power exhaust in the vertical configuration. The whole air path is therefore managed in one place, which simplifies filter maintenance and the ventilation settings.\u003c\/p\u003e\n\u003cp\u003eThe refrigeration side includes a single scroll compressor with protection against liquid-induced damage, a thermostatic expansion valve, a filter-drier and high and low pressure switches. The coils combine copper tubes and aluminum fins, and the cabinet's powder-coat finish is rated 750 hours in the salt spray test. A retail store sometimes has to be cooled as early as spring: the control allows cooling down to 40 °F (4 °C) outdoors with no additional component, and the economizer takes over with outdoor air when conditions allow.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated airflow: 1,550 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003eNet cooling (AHRI): 57,000 BTU\/h, for a rated capacity of 5 tons (60,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eHeating: 53,000 BTU\/h at 47 °F (8.3 °C), COP of 3.5; 29,000 BTU\/h at 17 °F (-8.3 °C), COP of 2.15\u003c\/li\u003e\n\u003cli\u003eEfficiency: 14.0 SEER2, 6.7 HSPF2 and 11.8 EER2\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eEnvelope (width x length x height): 48.9 x 74.1 x 40.6 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 627 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270): 77.8 dBA\u003c\/li\u003e\n\u003cli\u003eBackup heat: 6.5, 10.5 or 16 kW kits at 230 V, with reduced capacity at 208 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlanning the installation in a space open to the public\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSite visit, load calculation and assessment of the fresh air needs based on occupancy.\u003c\/li\u003e\n\u003cli\u003eChoice of the filtration level, the economizer and the smoke detectors.\u003c\/li\u003e\n\u003cli\u003eCheck of the return ducts and adjustment of the fan for the target airflow.\u003c\/li\u003e\n\u003cli\u003eRespect of the 36 in. rear clearance required with an economizer or a power exhaust.\u003c\/li\u003e\n\u003cli\u003eLifting and installation scheduled outside busy hours, then commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eYour 5 ton project, from the estimate to the maintenance\u003c\/h2\u003e\n\u003cp\u003eAt AirGreen, the same team follows your file from start to finish: free on-site estimate, sizing, selection of the air quality options, installation, commissioning and maintenance. During maintenance, we replace the filters, check the economizer and review the control's history. As an \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor from Montreal, we favour fast, efficient work, scheduled to disturb your customers and your patients as little as possible.\u003c\/p\u003e\n\u003cp\u003eCall 514\u0026nbsp;316-2973 or write to us using the form on airgreen.ca: we will quickly schedule the free on-site estimate for your business or your clinic, in Montreal, in Laval, in Longueuil, on the North Shore as on the South Shore.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367208005924,"sku":"WQE06A2B1AB5A111A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_f77934f2-c3d7-479e-8398-db3f3e1882da.png?v=1790963345"},{"product_id":"thermopompe-monobloc-york-wye-de-5-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WYE 5 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eWhen the electricity bill matters: the 5 ton high-efficiency version\u003c\/h2\u003e\n\u003cp\u003eIf you are the one paying the electricity for your business or your building, the purchase price of a rooftop unit is only part of the calculation. The unit will run for many years, in cooling as well as in heating, and a gain in efficiency carries over to every hour it operates. Model WYE06A2B1AB5A111A1 is the \u003cstrong\u003ehigh-efficiency\u003c\/strong\u003e version of the 5 ton YORK Sun Core packaged heat pump (60,000 BTU\/h nominal), in 208\/230 V three-phase and on R-454B refrigerant. AirGreen helps you compare it with the standard WQE06 version before you decide, for buildings in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eWYE06 and WQE06 side by side\u003c\/h3\u003e\n\u003cp\u003eBoth models share the same cabinet and the same design. Here are their main figures, taken from the YORK technical guide:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eWYE06 (high efficiency)\u003c\/th\u003e\n\u003cth\u003eWQE06 (standard efficiency)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e59,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e57,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e56,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP at 47 °F\u003c\/td\u003e\n\u003ctd\u003e3.6\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e29,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP at 17 °F\u003c\/td\u003e\n\u003ctd\u003e2.2\u003c\/td\u003e\n\u003ctd\u003e2.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e14.3\u003c\/td\u003e\n\u003ctd\u003e14.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e6.9\u003c\/td\u003e\n\u003ctd\u003e6.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e12.0\u003c\/td\u003e\n\u003ctd\u003e11.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input in cooling (AHRI rating)\u003c\/td\u003e\n\u003ctd\u003e4.9 kW\u003c\/td\u003e\n\u003ctd\u003e4.8 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input in heating at 47 °F\u003c\/td\u003e\n\u003ctd\u003e4.5 kW\u003c\/td\u003e\n\u003ctd\u003e4.4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input in heating at 17 °F\u003c\/td\u003e\n\u003ctd\u003e4.1 kW\u003c\/td\u003e\n\u003ctd\u003e3.9 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e1,650 CFM\u003c\/td\u003e\n\u003ctd\u003e1,550 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum circuit ampacity (MCA) at 208 V, without backup heat\u003c\/td\u003e\n\u003ctd\u003e29 A\u003c\/td\u003e\n\u003ctd\u003e25.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor sound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e80.0 dBA\u003c\/td\u003e\n\u003ctd\u003e77.8 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e653 lb\u003c\/td\u003e\n\u003ctd\u003e627 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe MCA values correspond to the medium static pressure configuration of both models, without a powered convenience outlet.\u003c\/p\u003e\n\u003ch3\u003eHow to read these ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2:\u003c\/strong\u003e seasonal cooling efficiency, that is the heat removed per unit of electricity consumed over a typical season.\u003c\/li\u003e\n\u003cli\u003eEER2: cooling efficiency at full load, measured at a high, fixed outdoor temperature; useful for judging performance in hot weather.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2:\u003c\/strong\u003e seasonal heating efficiency, calculated over a typical heating season.\u003c\/li\u003e\n\u003cli\u003eCOP: the instantaneous ratio between the heat delivered and the electricity consumed at a given outdoor temperature. At 47 °F (8.3 °C), a COP of 3.6 means 3.6 units of heat for every unit of electricity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the comparison shows\u003c\/h3\u003e\n\u003cp\u003eThe WYE06 draws a little more at full load, but it also delivers more capacity in cooling and in heating. Efficiency is measured by the ratio between those two values, and the high-efficiency version earns a better rating on every count: SEER2, EER2, HSPF2 and COP. The advantage holds in cold weather: at 17 °F (-8.3 °C), it delivers 30,000 BTU\/h with a COP of 2.2. When the backup heat is called on, every extra BTU delivered by the heat pump cuts back its contribution by that much, and those electric elements only turn electricity into heat.\u003c\/p\u003e\n\u003cp\u003eThe comparison also shows three points to plan for: a slightly larger electrical circuit, 26 lb more on the roof and a higher sound rating. We take them into account, especially when the unit sits close to windows or to neighbouring dwellings. The real difference on your bill depends on your operating hours, your rate and the load of your building; we therefore assess it from your own situation rather than with a generic percentage.\u003c\/p\u003e\n\u003ch3\u003eWhen the high-efficiency version is worth it\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe space is occupied long hours, every day, in cooling as well as in heating.\u003c\/li\u003e\n\u003cli\u003eThe owner pays for the electricity directly and is keeping the building for the long term.\u003c\/li\u003e\n\u003cli\u003eThe heat pump carries a large share of the heating, which brings its COP of 3.6 and 2.2 into play.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor a space occupied few hours, or when the purchase budget comes first, the WQE06 can be enough. We compare both options with you, figures in hand.\u003c\/p\u003e\n\u003ch3\u003eThe settings that count as much as the rating\u003c\/h3\u003e\n\u003cp\u003eAn oversized unit starts and stops more often, which wastes part of its efficiency. We therefore begin with a load calculation. According to the YORK nomenclature, this model carries the medium static pressure option: a belt-driven fan, a 2.4 HP three-phase motor and an adjustable drive pulley, which we set to the target airflow after measuring the static pressure of your ducts.\u003c\/p\u003e\n\u003cp\u003eThanks to the energy consumption tracking built into the \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control, operation can be matched to the real schedule and occupancy of the building. The control can also lock out the compressor when free cooling is available with an economizer, and its fan delays are programmed separately in heating and in cooling. The LCD display, the USB port and, depending on the model code, the BACnet MS\/TP, Modbus and N2 communication card make monitoring easier. Finally, regular maintenance of the filters and the coils helps the unit keep its original performance.\u003c\/p\u003e\n\u003ch3\u003eA packaged unit assembled and tested at the factory\u003c\/h3\u003e\n\u003cp\u003eIn a packaged heat pump, compressor, coils, fan and control share a single outdoor cabinet, installed on the roof or on the ground and connected to the supply and return ducts. The refrigerant circuit is not joined in the field between two units: it is assembled at the factory, and every unit is configured and run-tested before delivery. The single scroll compressor, designed with fewer moving parts, contributes to a quiet, reliable, easy-to-service and efficient system.\u003c\/p\u003e\n\u003ch3\u003eEvery figure for the WYE06 model\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEfficiency ratings: 14.3 SEER2, 6.9 HSPF2 and 12.0 EER2\u003c\/li\u003e\n\u003cli\u003eCOP: 3.6 at 47 °F (8.3 °C) and 2.2 at 17 °F (-8.3 °C)\u003c\/li\u003e\n\u003cli\u003eNominal capacity: 5 tons (60,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 59,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating: 56,000 BTU\/h at 47 °F (8.3 °C) and 30,000 BTU\/h at 17 °F (-8.3 °C)\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 1,650 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eOverall dimensions (width x length x height): 48.9 x 74.1 x 40.6 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 653 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound rating (AHRI 270): 80.0 dBA\u003c\/li\u003e\n\u003cli\u003eField-installed backup heat: 6.5, 10.5 or 16 kW kits at 230 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSame dimensions, same roof curb\u003c\/h3\u003e\n\u003cp\u003eChoosing high efficiency does not complicate the installation. The WYE06 has the same dimensions as the WQE06 and uses the same 14 in. or 24 in. YORK roof curbs, the same hail guard and the same economizers. It also sits on a good number of existing roof curbs thanks to its full perimeter base rail. You find the construction shared across the line: thermostatic expansion valve, filter drier, high and low pressure switches, copper and aluminum coils, embossed top and powder paint rated for 750 hours of salt spray, all rated to cool up to 125 °F (52 °C).\u003c\/p\u003e\n\u003ch2\u003eChoosing the right efficiency level with AirGreen\u003c\/h2\u003e\n\u003cp\u003eBetween the standard version and the high-efficiency version, the right choice depends on your building, your occupancy hours and your electrical service. During the free on-site estimate, we run the load calculation, check the roof curb, the ducts and the electrical entrance, then we lay out both options transparently. Once your choice is made, we install the unit, commission it and maintain it. As a Montreal \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor, we work quickly and efficiently.\u003c\/p\u003e\n\u003cp\u003eOur on-site estimates are free everywhere in Montreal, Laval, Longueuil, the North Shore and the South Shore. Reach us at 514 316-2973 or through the form on airgreen.ca to compare both versions in your own building.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367208038692,"sku":"WYE06A2B1AB5A111A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_ef287294-da26-4414-be0f-81aa1f9d9ae4.png?v=1790963326"},{"product_id":"thermopompe-monobloc-york-xn-de-4-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XN 4 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eReplacing an R-410A rooftop unit without changing your bearings\u003c\/h2\u003e\n\u003cp\u003eYour rooftop unit is reaching the end of its life and the rest of your equipment fleet runs on \u003cstrong\u003eR-410A\u003c\/strong\u003e. You can replace it with a heat pump from the same refrigerant family: the 4 ton YORK Sunline XN (48,000 BTU\/h nominal), powered at 208\/230 V three-phase. At AirGreen, an \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor based in Montreal, we replace rooftop units on businesses and buildings in Laval, in Longueuil, on the North Shore and on the South Shore. Here is what you need to know to carry out a like-for-like replacement.\u003c\/p\u003e\n\u003ch3\u003eThe packaged concept, seen from a replacement standpoint\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e brings the whole system together in a single outdoor cabinet: scroll compressor, outdoor coil, indoor coil, supply fan, filters and control. Inside the building, all that is left are the ducts that distribute the air. YORK ships every XN unit charged with refrigerant, wired, piped and tested at the factory, which keeps site work to a minimum.\u003c\/p\u003e\n\u003cp\u003eDuring a replacement, the old unit comes off its roof curb and the new one takes its place, connected to the same duct openings. The YORK guide also provides for installation on a ground-level pad or on steel beams.\u003c\/p\u003e\n\u003ch3\u003eR-410A: proven technology, familiar maintenance\u003c\/h3\u003e\n\u003cp\u003eR-410A is the previous-generation refrigerant, used for many years in commercial rooftop units. The technicians who already service your equipment know its service procedures: the same habits and the same diagnostic approach from one unit to the next.\u003c\/p\u003e\n\u003cp\u003eThe XN048 comes with a factory charge of 13 lb 10 oz of R-410A. Its circuit includes a filter-drier, high and low pressure switches and a freeze protection thermostat on the suction line. Service ports on the suction and liquid lines make it possible to read pressures without losing refrigerant.\u003c\/p\u003e\n\u003ch3\u003eKey specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated capacity:\u003c\/strong\u003e 4 tons (48,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 47,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 44,000 BTU\/h, COP of 3.2\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 24,900 BTU\/h, COP of 2.1\u003c\/li\u003e\n\u003cli\u003eEfficiency under the previous standard (no SEER2 rating published for the XN series): SEER 14.0, HSPF 8.0 and EER 11.8\u003c\/li\u003e\n\u003cli\u003eRated airflow: 1,450 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V, three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 44.88 x 82.25 x 32.63 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 616 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270 rating): 80 dB(A)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFactory configuration of this model\u003c\/h3\u003e\n\u003cp\u003eModel number XN048C00B2C1AAA1A2 describes the equipment as it leaves the factory:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003estandard static pressure indoor fan, belt driven\u003c\/li\u003e\n\u003cli\u003efactory-installed economizer, without barometric relief damper\u003c\/li\u003e\n\u003cli\u003eno service option, so no built-in disconnect and no convenience outlet\u003c\/li\u003e\n\u003cli\u003eno optional sensor\u003c\/li\u003e\n\u003cli\u003estand-alone Smart Equipment control\u003c\/li\u003e\n\u003cli\u003estandard coils, without E-Coat coating\u003c\/li\u003e\n\u003cli\u003eheat pump without factory-installed electric heat (code C00)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003eeconomizer\u003c\/strong\u003e can bring in up to 100% outdoor air when that air is cool enough, which allows cooling in mid-season with the compressor off. The dampers, of the low-leakage type (AMCA 511, class 1A), close completely in the event of a power failure. If excess air has to be relieved while it runs, a barometric relief damper is added as an accessory.\u003c\/p\u003e\n\u003ch3\u003eWhat makes the replacement simpler on the roof\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommon roof curb:\u003c\/strong\u003e all ZE\/XN models from 3 to 6 tons share the same cabinet and the same curb. If your current unit belongs to this YORK family, the new one sits on the curb already in place, once its condition has been checked.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConvertible connections:\u003c\/strong\u003e through the bottom or horizontally through the back, even with the economizer. You only have to remove the corresponding sheet metal panels.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eService entries:\u003c\/strong\u003e knockouts under the unit and on the side, plus a marked location for mounting a field-supplied disconnect.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdjustable airflow:\u003c\/strong\u003e the belt drive includes an adjustable-pitch motor sheave to match the fan speed to your existing ducts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReadings without disassembly:\u003c\/strong\u003e ports on the cabinet make it possible to measure indoor fan performance without removing a panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eChecking the existing electrical circuit\u003c\/h3\u003e\n\u003cp\u003eFor this configuration, without electric heat, the YORK guide lists a minimum circuit ampacity (MCA) of 24.2 A and a maximum overcurrent protection of 30 A, with a time-delay fuse or an HACR type breaker. The allowable voltage runs from 187 to 252 V. We compare these values with the old unit's circuit before confirming the replacement.\u003c\/p\u003e\n\u003ch3\u003eHeating: the heat pump first, electric backup next\u003c\/h3\u003e\n\u003cp\u003eIn heating mode, the XN048 delivers 44,000 BTU\/h at 47 °F (8.3 °C) with a COP of 3.2, then 24,900 BTU\/h at 17 °F (-8.3 °C) with a COP of 2.1. As with any heat pump, capacity drops as the outdoor temperature falls. For the Quebec winter, we therefore plan for \u003cstrong\u003eelectric backup heat\u003c\/strong\u003e sized to your building's heat loss.\u003c\/p\u003e\n\u003cp\u003eFor this model, the YORK guide lists the E05, E07, E10, E15 and E20 kits. Their capacity depends on the actual voltage: the E10 kit delivers 8 kW at 208 V and 10.6 kW at 230 V. The nickel-chrome elements, protected by thermal limit switches, connect to a single power supply, and the heater section slides out of the unit for maintenance.\u003c\/p\u003e\n\u003ch3\u003eSmart Equipment: clearer diagnostics than before\u003c\/h3\u003e\n\u003cp\u003eOn XN heat pumps, the \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control comes standard. Its LCD screen shows unit status, supply air, return air and outdoor air temperatures as well as fault codes. The USB port is used for data logging, fault review, software updates and start-up reports.\u003c\/p\u003e\n\u003cp\u003eThe control accepts a conventional thermostat, a zone sensor or a building management system. It includes a short-cycle delay and locks out the compressor only after three trips of a safety within two hours. The last five alarms stay in memory, even after a power outage. Thanks to the built-in low ambient control, the unit cools down to 0 °F (-17.8 °C) outdoors, without any accessory.\u003c\/p\u003e\n\u003ch3\u003eInstallation tips for a successful replacement\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSurvey of the existing unit: capacity, power supply, curb dimensions and position of the duct openings.\u003c\/li\u003e\n\u003cli\u003eLifting: the perimeter base rails have lifting holes at the four corners for the crane and forklift openings on three sides.\u003c\/li\u003e\n\u003cli\u003eClearances with the economizer: 24 in. at the front, 36 in. at the rear, 36 in. on the left side for filter access, 24 in. on the right side and 72 in. above the unit.\u003c\/li\u003e\n\u003cli\u003eCondensate: 3\/4 in. female PVC connection, to be protected from freezing depending on the drain routing.\u003c\/li\u003e\n\u003cli\u003eFilters: three 1 in. disposable filters on delivery, in a rack that also accepts 2 in. filters.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eWhy entrust this replacement to AirGreen\u003c\/h2\u003e\n\u003cp\u003eA rooftop unit replacement comes down to the details: curb, power supply, lifting, ducts and airflow adjustment. Our crews handle all of it from start to finish.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree on-site estimate:\u003c\/strong\u003e we go up on the roof, we survey the existing unit and we check the curb, the ducts and the electrical circuit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSizing:\u003c\/strong\u003e we confirm that 4 tons suits your cooling and heating loads, then we select the appropriate electric backup kit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation by our own crews:\u003c\/strong\u003e removal of the old unit, lifting, connections, commissioning and programming of the Smart Equipment control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e filters, coils, belt and a check of the safeties, on a schedule suited to your building.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe serve Montreal, Laval, Longueuil, the North Shore and the South Shore. To replace your R-410A rooftop unit with a 4 ton YORK XN packaged heat pump, call 514\u0026nbsp;316-2973 or use the form on airgreen.ca. We will book your free on-site estimate quickly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367209578788,"sku":"XN048C00B2C1AAA1A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUNLINE_WN_XN_00_PRINCIPALE_8f21b4ff-3045-423d-95c9-867e5122c143.png?v=1790963309"},{"product_id":"thermopompe-monobloc-york-xn-de-5-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XN 5 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eFive tons of comfort for a large space in 208\/230 V three-phase\u003c\/h2\u003e\n\u003cp\u003eA showroom, a retail store or an open-plan office needs a lot of air, well distributed, in summer as in winter. The 5 ton YORK Sunline XN \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e (60,000 BTU\/h nominal) meets that need with a nominal airflow of 1,850 CFM and a 208\/230 V three-phase supply, common in commercial buildings. AirGreen, an HVAC contractor in Montreal, installs it on roofs in Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eThe capacities at a glance\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e5 tons (60,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e55,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e51,500 BTU\/h, COP of 3.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h, COP of 2.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency (former standard)\u003c\/td\u003e\n\u003ctd\u003eSEER 14.0, HSPF 8.0, EER 11.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e1,850 CFM (ft³\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, three-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (width x length x height)\u003c\/td\u003e\n\u003ctd\u003e44.88 x 82.25 x 32.63 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e620 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor sound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e80 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe XN series is rated under the former SEER and HSPF standard. The YORK technical guide does not publish SEER2 or HSPF2 ratings for these models.\u003c\/p\u003e\n\u003ch3\u003eA large volume of air, at two speeds\u003c\/h3\u003e\n\u003cp\u003eIn a large space, airflow counts as much as tonnage. For the XN060, the YORK guide publishes separate capacity tables for a low speed and a high speed, with a nominal airflow of 1,275 CFM at low speed and 1,850 CFM at high speed. The double-inlet centrifugal indoor blower is dynamically balanced and mounted on sealed bearings, lubricated for life. Its belt drive includes an adjustable-pitch drive pulley, which lets us match the speed to the duct system.\u003c\/p\u003e\n\u003ch3\u003eA two-speed outdoor fan\u003c\/h3\u003e\n\u003cp\u003eThe 5 ton model is the only one in the XN series whose \u003cstrong\u003eoutdoor fan\u003c\/strong\u003e has two speeds: 850 and 1,100 rpm, for an airflow of 2,800 or 3,800 CFM through the outdoor coil. This 24 in. direct-drive propeller fan discharges the air vertically. Its aluminum blades are riveted to a corrosion-resistant steel support and dynamically balanced, and its enclosed motor is protected against overloads.\u003c\/p\u003e\n\u003ch3\u003eSide or bottom connection\u003c\/h3\u003e\n\u003cp\u003eEvery XN model, including those fitted with an economizer, connects from the bottom or horizontally. For a bottom connection, we remove the sheet metal panels that close the supply and return openings in the base of the unit. For a side connection, which YORK calls horizontal, we remove the supply and return panels at the back of the unit. The bottom connection suits ducts that pass through the roof inside the base. The horizontal connection is used when the ducts come in through a wall, for example when the unit sits on a pad on the ground.\u003c\/p\u003e\n\u003cp\u003eThe power wiring enters at a single point, from the side or from underneath, through a 2 in. knockout. The control wiring has its own 7\/8 in. openings, also on the side and under the unit. Fewer penetrations in the roof means less risk of a leak.\u003c\/p\u003e\n\u003ch3\u003eTwo factory configurations offered\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eXN060C00B2C1AAA1A2:\u003c\/strong\u003e standard static pressure belt-driven blower, economizer without a barometric relief damper, no service option, no optional sensor, stand-alone Smart Equipment control and standard coils.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eXN060C00D2A1AAA1A2:\u003c\/strong\u003e high static pressure blower, no economizer, with the same choices for the service options, the sensors, the control and the coils.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBoth versions ship without factory-installed electric heat (code C00). The high static pressure version suits long or restrictive duct systems. The version with an economizer brings in up to 100% outdoor air when it is cool enough to cool without the compressor. We recommend one or the other after measuring the static pressure of your ducts.\u003c\/p\u003e\n\u003ch3\u003eThe packaged principle applied to large floor areas\u003c\/h3\u003e\n\u003cp\u003eIn a packaged unit, the scroll compressor, both coils, the fans, the filters and the control share a single outdoor cabinet. Installed on the roof or on the ground, it connects to the building's ducts. No indoor mechanical room is required, which leaves the whole floor area for your operations. In winter, the heat pump reverses its cycle to heat. Every XN unit goes through automated factory tests of the refrigerant charge, the pressures, the current draw and all of its functions.\u003c\/p\u003e\n\u003ch3\u003eBackup heat and electrical supply\u003c\/h3\u003e\n\u003cp\u003eThe XN060 delivers 51,500 BTU\/h of heating at 47 °F (8.3 °C) and 30,000 BTU\/h at 17 °F (-8.3 °C). In deep cold, \u003cstrong\u003eelectric backup heat\u003c\/strong\u003e supplements the heat pump. For this model in 208\/230 V, the YORK guide lists the E05 through E30 kits. The largest delivers 22.2 kW at 208 V and 29.6 kW at 230 V: the building's actual voltage therefore counts in the choice of kit.\u003c\/p\u003e\n\u003cp\u003eWithout electric heat, the standard static pressure configuration calls for a circuit of at least 27.7 A (MCA) protected at 35 A maximum. The voltage range the unit accepts runs from 187 to 252 V. We confirm these values according to the kit selected, before ordering.\u003c\/p\u003e\n\u003ch3\u003eControl, protections and maintenance\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control, standard on XN heat pumps, works with a conventional thermostat or a zone sensor. Its fan delays are programmable, with separate settings for heating and cooling. Freeze thermostats on the suction line protect against loss of charge and coil frosting when the economizer runs in cool weather while the compressor is turning. The compressor has internal protection, and the high and low pressure switches are monitored individually.\u003c\/p\u003e\n\u003cp\u003eFor maintenance, the large cabinet panels come off easily. The condensate pan, sloped inward, is designed to drain on its own in line with the ASHRAE 62 standard. Finally, the galvanized steel cabinet carries a powder paint finish that passed the 750-hour salt spray test.\u003c\/p\u003e\n\u003ch3\u003eInstallation advice for a large space\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eLoad calculation: glazing, occupancy and internal gains decide whether 5 tons is enough.\u003c\/li\u003e\n\u003cli\u003eMeasurement of the duct static pressure, to choose between the standard version and the high static pressure version.\u003c\/li\u003e\n\u003cli\u003eRoof curb: YORK offers 8 in. and 14 in. curbs that meet NRCA requirements, shipped knocked down, with a wood nailer strip and duct supports.\u003c\/li\u003e\n\u003cli\u003eClearances: 24 in. at the front, 24 in. on the right side and 72 in. above. At the back, 36 in. with an economizer or 12 in. without an economizer. On the left side, 36 in. with an economizer or 24 in. without.\u003c\/li\u003e\n\u003cli\u003eCrane lifting thanks to the lifting holes at the four corners of the base rails.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eTrusting your 5 ton project to AirGreen\u003c\/h2\u003e\n\u003cp\u003eWe support owners, building managers and general contractors in Montreal, Laval, Longueuil, the North Shore and the South Shore at every step:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, with a survey of the space, the roof and the electrical entrance\u003c\/li\u003e\n\u003cli\u003esizing of the unit and of the backup heat according to your actual loads\u003c\/li\u003e\n\u003cli\u003einstallation, lifting, connections and commissioning by our own crews\u003c\/li\u003e\n\u003cli\u003escheduled maintenance of the filters, the belt and the coils to preserve the airflow\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTo receive your estimate, call 514 316-2973 or write to us through the form on airgreen.ca. We answer quickly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367209611556,"sku":"XN060C00B2C1AAA1A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUNLINE_WN_XN_00_PRINCIPALE_cb4094a3-668d-496e-ba60-eb1ffb0dad3e.png?v=1790963291"},{"product_id":"thermopompe-monobloc-york-xn-de-5-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XN 5 Ton 575V | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eA 5-ton R-410A unit designed for industrial 575 V\u003c\/h2\u003e\n\u003cp\u003eAround Montreal, whether in Laval, in Longueuil, on the North Shore or on the South Shore, many industrial buildings are fed at \u003cstrong\u003e575 V three-phase\u003c\/strong\u003e and keep a fleet of equipment on R-410A. The 5-ton YORK Sunline XN (60,000 BTU\/h nominal) in its 575 V version fits that logic: a rooftop \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e that connects to your electrical distribution and uses the refrigerant your teams already know. At AirGreen, we install it to cool and heat offices, mezzanines and staff rooms.\u003c\/p\u003e\n\u003ch3\u003eConnected directly to your 575 V distribution\u003c\/h3\u003e\n\u003cp\u003eThe unit is built for 575 V three-phase at 60 Hz. No step-down transformer is needed to feed it, and the YORK guide allows an operating voltage from 540 to 630 V. For the configuration delivered, without electric heat, the guide's table gives an MCA (minimum circuit ampacity) of 9.9 A and a protective device of no more than 15 A, a time-delay fuse or an HACR breaker.\u003c\/p\u003e\n\u003cp\u003eFor backup heat, in 575 V the guide lists the E10, E15, E20 and E30 kits, that is 10.6, 15.9, 21.2 and 30.4 kW. The nickel-chrome elements, wired to a single supply, are protected by auto-reset thermal limit switches.\u003c\/p\u003e\n\u003ch3\u003eBase rails: from the forklift to the crane\u003c\/h3\u003e\n\u003cp\u003eThe perimeter \u003cstrong\u003ebase rails\u003c\/strong\u003e, permanently fastened, form a rigid footing and protect the unit during transport. They give forklift access on three sides, which makes handling in the yard or on the dock easier. Lifting holes at the four corners then allow the unit to be hoisted onto the roof with a crane.\u003c\/p\u003e\n\u003cp\u003eThe XN060 weighs 625 lb shipping and 620 lb in operation. The YORK guide gives the centre of gravity and the load at each support point: on four-point support, 132, 117, 174 and 197 lb. These figures help the engineer validate the roof structure. If the roof is not well suited to it, the XN series can also rest on a pad at grade or on steel beams above the finished roof.\u003c\/p\u003e\n\u003ch3\u003eThe low-ambient control, for cooling out of season\u003c\/h3\u003e\n\u003cp\u003eAn industrial building often gives off heat all year long. The built-in \u003cstrong\u003elow-ambient control\u003c\/strong\u003e lets the XN060 cool down to 0 °F (-17.8 °C) outdoors with no additional accessory, in a comfort application for the occupants. This model also includes an economizer, which cools with outdoor air when it is cool enough. Proven over 60,000 cycles, it carries low-leakage dampers certified to AMCA 511 Class 1A, which close on their own during a power failure. The control can be programmed to lock out the compressor in cold weather or when this free cooling is available.\u003c\/p\u003e\n\u003cp\u003eTo cool an electrical room or a server room, the YORK guide recommends instead contacting its applications department, since additional accessories may be needed for stable operation. We make that check with you right at the estimate.\u003c\/p\u003e\n\u003ch3\u003eA control the maintenance team reads at a glance\u003c\/h3\u003e\n\u003cp\u003eFitted as standard on every XN heat pump, the \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control comes with factory-installed supply, return and outdoor air temperature sensors. Its LCD screen and its control knob give access to the unit's status, the function under way and the fault codes. Through the USB port, your technician pulls the data log, the current and previous faults as well as the self-diagnostic and start-up reports.\u003c\/p\u003e\n\u003cp\u003eTo avoid needless calls, the compressor is locked out only after three trips of the pressure switches or of the freeze thermostats within two hours, and the last five alarms stay in memory even after a power failure. In dusty settings, we adjust how often the 1 in. disposable filters are changed, and a dirty filter switch can be added as an accessory.\u003c\/p\u003e\n\u003ch3\u003eTechnical data for the 575 V XN060\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet AHRI cooling:\u003c\/strong\u003e 55,400 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating:\u003c\/strong\u003e 51,500 BTU\/h at 47 °F (8.3 °C), COP of 3.35, and 30,000 BTU\/h at 17 °F (-8.3 °C), COP of 2.14\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e SEER 14.0, HSPF 8.0 and EER 11.0 (the former rating standard, the only one published for the XN series)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow:\u003c\/strong\u003e 1,850 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 575 V, three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 44.88 x 82.25 x 32.63 in. (width x length x height)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating weight:\u003c\/strong\u003e 620 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor sound level:\u003c\/strong\u003e 80 dB(A), AHRI 270 rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R-410A, a previous-generation refrigerant, proven technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConfiguration delivered: XN060C00B5C1AAA1A2\u003c\/h3\u003e\n\u003cp\u003eThis model number corresponds to a unit with a standard static pressure indoor fan, belt-driven, with an economizer without a barometric relief damper. It has no service option and no optional sensor, and it comes with the stand-alone Smart Equipment control and standard coils. It is delivered with no factory-installed electric heat (code C00). Since it has no built-in disconnect, the disconnect is supplied on site and fastened at the location YORK provides on the cabinet.\u003c\/p\u003e\n\u003ch3\u003eA build that holds up in an industrial setting\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eGalvanized steel cabinet, powder paint finish certified to the 750-hour salt spray test (ASTM B117)\u003c\/li\u003e\n\u003cli\u003eScroll compressor with internal spring isolation and sound attenuation, externally isolated on an independent mount\u003c\/li\u003e\n\u003cli\u003eStart-up and operation possible up to 125 °F (52 °C) outdoors\u003c\/li\u003e\n\u003cli\u003eInternal compressor protection, high and low pressure switches and freeze thermostats\u003c\/li\u003e\n\u003cli\u003eAccessories offered: coil guard, hail hood and burglar bars for the supply and return openings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe packaged principle in a plant or a warehouse\u003c\/h3\u003e\n\u003cp\u003eA packaged unit groups the compressor, the coils, the fans, the filters and the control in a single outdoor cabinet. The refrigerant circuit stays entirely inside the unit: no refrigerant line runs through the plant. Only the supply and return ducts drop down to the offices or the mezzanine served, from the bottom of the unit or horizontally depending on the route. Every unit is charged, wired and tested at the factory, which shortens the work on site.\u003c\/p\u003e\n\u003ch3\u003eInstallation pointers\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePlan the 575 V circuit and the disconnect, then confirm the rating according to the heat kit chosen.\u003c\/li\u003e\n\u003cli\u003eHave the roof load validated: a 620 lb unit, an 8 or 14 in. roof curb and the load distribution from the YORK guide.\u003c\/li\u003e\n\u003cli\u003ePlan the crane access and the forklift handling before the day of the lift.\u003c\/li\u003e\n\u003cli\u003eLeave 24 in. clear in front of the unit, 36 in. behind and on the left side (economizer and filters), 24 in. on the right side and 72 in. above.\u003c\/li\u003e\n\u003cli\u003eBring the supply in on the side or from below the unit, at a single point, to limit the penetrations.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eOur teams at the service of your industrial building\u003c\/h2\u003e\n\u003cp\u003eA Montreal HVAC contractor, AirGreen sells and installs its equipment. For a 575 V project, everything starts with a \u003cstrong\u003efree on-site estimate:\u003c\/strong\u003e we survey the rooms to be served, the electrical service and the roof. We then size the unit and the backup heat, we coordinate the lift and our teams handle the installation, the commissioning and the maintenance.\u003c\/p\u003e\n\u003cp\u003eWe work in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. To arrange the visit, call 514 316-2973 or go through the contact form on airgreen.ca.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367211512100,"sku":"XN060C00B5C1AAA1A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUNLINE_WN_XN_00_PRINCIPALE_c9da7f7d-d499-4278-b07c-cc703726f966.png?v=1790963267"},{"product_id":"thermopompe-monobloc-york-xp-de-7-5-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XP 7.5 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eA mid-size business deserves cooling that follows its traffic\u003c\/h2\u003e\n\u003cp\u003eA store that fills up on Saturday, a dining room that goes from a quiet afternoon to the rush of dinner service, offices that empty out at the end of the day: the thermal load of a business changes from hour to hour. This packaged heat pump from the YORK Sun Pro series answers that reality with \u003cstrong\u003etwo scroll compressors\u003c\/strong\u003e and two stages of cooling, on the \u003cstrong\u003e208\/230 V three-phase\u003c\/strong\u003e supply found in a good number of commercial spaces. At AirGreen, we supply it, install it and maintain it for merchants, owners and building managers in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eThe whole system in a single cabinet, on the roof\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e brings the compressors, the coils, the fans and the controls together in a single outdoor cabinet. Set on a roof curb, on a pad or on a structure, it connects directly to the building's supply and return ducts. For a business, the gain is concrete: no indoor unit takes up sales or storage space, and our technicians work on the roof without disturbing your customers. The same machine cools in summer and heats by heat pump the rest of the year, with the option of adding electric backup heat.\u003c\/p\u003e\n\u003cp\u003eEvery Sun Pro unit leaves the factory charged with refrigerant, wired, piped and tested. It runs on \u003cstrong\u003eR-410A\u003c\/strong\u003e, the previous-generation refrigerant: a proven technology that refrigeration technicians know well.\u003c\/p\u003e\n\n\u003ch3\u003eTwo compressors, two stages, efficiency measured at part load\u003c\/h3\u003e\n\u003cp\u003eThe two scroll compressors feed two independent refrigeration circuits, with steps at 50% and 100% of capacity. On a mild day, one compressor can be enough; the second comes in when the sun hits the storefront or the space fills up. This staging limits on-off cycling and helps hold a steady temperature for your customers and your staff. A compressor swap function (lead-lag), selectable on the control board, can also even out their running hours.\u003c\/p\u003e\n\u003cp\u003eThe efficiency ratings reflect that behaviour. The \u003cstrong\u003e11.2 EER\u003c\/strong\u003e measures full-load performance, while the \u003cstrong\u003e14.6 IEER\u003c\/strong\u003e, obtained with the IntelliSpeed drive, takes part-load operation into account and gives a better picture of a real season of use. Like every unit of 6 tons and up, this model is rated in EER and IEER, not in SEER.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications of the model\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated capacity: 7.5 tons (90,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 92,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 87,000 BTU\/h, COP of 3.5\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 51,000 BTU\/h, COP of 2.25\u003c\/li\u003e\n\u003cli\u003eEfficiency: 11.2 EER and 14.6 IEER\u003c\/li\u003e\n\u003cli\u003eRated airflow: 3,000 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V, three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eCompressors: 2 scroll, steps at 50% and 100%\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-410A, thermostatic expansion valves (TXV)\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 59 x 89 x 50.75 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 1,090 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270): 83 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe factory configuration of this model\u003c\/h3\u003e\n\u003cp\u003eThe number XP090C00R2B1BAA1A2 reads option by option in the YORK nomenclature. Here is what it includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e with high static pressure drive package (3 HP motor): the supply fan speed varies with the number of compressors or heating stages running, and the minimum economizer position is set according to the drive frequency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEconomizer\u003c\/strong\u003e with barometric relief damper, to take advantage of cool outdoor air in the shoulder seasons.\u003c\/li\u003e\n\u003cli\u003ePhase monitor, which protects the unit against phase loss and reverse rotation.\u003c\/li\u003e\n\u003cli\u003eStand-alone Smart Equipment control, compatible with a thermostat or a zone sensor.\u003c\/li\u003e\n\u003cli\u003eStandard coils, without E-Coat coating.\u003c\/li\u003e\n\u003cli\u003eNo factory service option: no disconnect switch and no convenience outlet, the disconnect is planned for in the field.\u003c\/li\u003e\n\u003cli\u003eDisposable 2 in. filters, standard cabinet and no factory-installed electric heat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe Sun Pro strengths that simplify day-to-day management\u003c\/h3\u003e\n\u003ch4\u003eFast, tool-free maintenance\u003c\/h4\u003e\n\u003cp\u003eTool-free hinged panels give access to the control box, the compressors, the filters, the motor and the indoor blower. The non-corrosive condensate pan slides out the back of the unit for cleaning, and service windows cut into both condenser walls make coil inspection easier. The motor-and-blower assembly slides out, and a second nameplate, placed inside the control door, stays legible despite the weather.\u003c\/p\u003e\n\u003ch4\u003eA control that reports clearly\u003c\/h4\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e board has an LCD screen and a navigation joystick: unit status, supply, return and outdoor temperatures, fault codes. Its USB port lets you review the fault history, run software updates and pull the self-test and start-up reports. The air sensors are factory-installed, the supply voltage is monitored for brownouts, and an anti-short-cycle delay protects the compressors. If a safety device trips three times in two hours, only the associated compressor is locked out, and a message is displayed.\u003c\/p\u003e\n\u003ch4\u003eA build designed for the roof\u003c\/h4\u003e\n\u003cp\u003eFreeze thermostats on the suction line, solid-core filter driers, high and low pressure switches and crankcase heaters are standard equipment. The galvanized steel cabinet gets a powder paint proven by a 750-hour salt spray test. The built-in low-ambient control allows cooling down to 0 °F (-17.8 °C) outdoors with no additional component, useful for spaces that give off heat even in winter.\u003c\/p\u003e\n\n\u003ch3\u003eGetting the 208\/230 V three-phase installation right\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e the YORK guide calls for an applied voltage of 187 to 252 V. We check the three-phase service and the panel capacity, especially if backup heat is planned.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric heat:\u003c\/strong\u003e for this size, YORK offers 9, 18, 24 or 36 kW kits, designed for a single-point power connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof curb:\u003c\/strong\u003e available in 8 in. or 14 in., with an insulated deck. The roof curb is common to the whole Sun Pro series from 6.5 to 12.5 tons, and a 10 in. transition curb makes it possible to reuse the footprint of an older Sunline unit from 7.5 to 12.5 tons.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifting:\u003c\/strong\u003e the full-perimeter base rails have lifting holes for the crane and fork slots on three sides.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 72 in. above, 36 in. at the front, at the back and on the left, 12 in. on the right.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDucts:\u003c\/strong\u003e bottom or side connection; the conversion is done by moving the factory covers, with no panel cutting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eAirGreen supports your Sun Pro project, from the estimate to the maintenance\u003c\/h2\u003e\n\u003cp\u003eIt all starts with a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e. We take down the floor area, the occupancy, the condition of the ducts, the electrical service and the roof access, then we confirm that 7.5 tons really is the right match for your space rather than a neighbouring size in the series. Our teams coordinate the lift, install the unit, connect the ducts and carry out the start-up: economizer setting, IntelliSpeed parameters and Smart Equipment control configuration. We then offer planned maintenance: filters, coils, belt, condensate pan and a reading of the fault history.\u003c\/p\u003e\n\u003cp\u003eAs an HVAC contractor, we serve businesses in Montreal, Laval, Longueuil, the North Shore and the South Shore with fast and efficient service calls. To schedule your visit, call us at 514 316-2973 or fill out the form on airgreen.ca: we will get back to you quickly with a clear quote.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367217377572,"sku":"XP090C00R2B1BAA1A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_PRO_00_PRINCIPALE_dc6a782e-8cf1-42c3-b40e-23a8c65172f8.png?v=1790963249"},{"product_id":"thermopompe-monobloc-york-xp-de-7-5-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XP 7.5 Ton 575V | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eThe 7.5 ton Sun Pro capacity, connected to the 575 V network of your industrial building\u003c\/h2\u003e\n\u003cp\u003eIn a factory, a warehouse or a shop supplied at 575 V, cooling the offices, the break room or a light production area should not call for a step-down transformer. This YORK Sun Pro packaged heat pump delivers exactly the same capacity as the 208\/230 V version, but it is built for \u003cstrong\u003e575 V three-phase\u003c\/strong\u003e. Our teams take care of the lift, the \u003cstrong\u003ecommissioning\u003c\/strong\u003e and the maintenance, so your maintenance staff does not have to get to know a new unit on their own. We work in industrial buildings in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the 575 V version changes\u003c\/h3\u003e\n\u003cp\u003eThe YORK guide allows an applied voltage from 540 to 630 V for this version. The connection is made directly on the building's 575 V distribution, and the electrical accessories follow the same voltage: the electric heat kits of 9, 18, 24 and 36 kW and the powered exhaust fan are available in 575 V. Performance, for its part, stays identical to that of the 208\/230 V model: same net cooling, same EER and IEER ratings, same airflow.\u003c\/p\u003e\n\u003cp\u003eOne point deserves your attention: this unit is meant for human comfort. For a process application, such as a server room or an electrical room, YORK recommends consulting its applications department. We take that step for you when your project comes close to it.\u003c\/p\u003e\n\n\u003ch3\u003eA single cabinet on the roof, the plant floor stays clear\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e brings together in one outdoor cabinet everything a split system spreads between the indoor and the outdoor side: compressors, coils, fans and control. Installed on a roof curb, a pad or a steel structure, it feeds the ducts that serve your offices or your work area, and it provides both cooling and heat pump heating. No equipment clutters the production floor, and all the work is done outside.\u003c\/p\u003e\n\u003cp\u003eThe unit arrives charged with \u003cstrong\u003eR-410A\u003c\/strong\u003e, wired, piped and factory tested. This previous-generation refrigerant is a proven technology, well known to refrigeration technicians.\u003c\/p\u003e\n\n\u003ch3\u003eThe performance data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e7.5 tons (90,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e92,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e87,000 BTU\/h, COP of 3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e51,000 BTU\/h, COP of 2.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER \/ IEER\u003c\/td\u003e\n\u003ctd\u003e11.2 \/ 14.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e3,000 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e575 V, three-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressors\u003c\/td\u003e\n\u003ctd\u003e2 scroll, two stages (50% \/ 100%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (width x length x height)\u003c\/td\u003e\n\u003ctd\u003e59 x 89 x 50.75 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e1,090 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor sound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e83 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eThe configuration as delivered\u003c\/h3\u003e\n\u003cp\u003eThe XP090C00R5B1BAA1A2 model includes an \u003cstrong\u003eIntelliSpeed variable-speed drive\u003c\/strong\u003e with a high static pressure drive, an economizer with a barometric relief damper, a phase monitor, the stand-alone Smart Equipment control and standard coils. It has no factory service option (no disconnect switch and no convenience receptacle) and no factory-installed electric heat: the disconnect switch and, if needed, the heat kit are added in the field. It ships with 2 in. disposable filters.\u003c\/p\u003e\n\n\u003ch3\u003eA build made for an industrial roof\u003c\/h3\u003e\n\u003cp\u003eBefore leaving the factory, every Sun Pro unit goes through computer-automated tests: refrigerant charge and pressure, electrical current and full operation. The galvanized steel cabinet receives a powder paint that has passed a 750 hour salt spray test, and the full perimeter base rails protect the unit during transport and lifting, with forklift slots on three sides. Aluminum-faced and elastomeric rubber insulation, used throughout the cabinet, supports indoor air quality. Finally, the built-in low-ambient control keeps cooling down to 0 °F (-17.8 °C) outdoors, an advantage when equipment gives off heat in your offices or your control room in the middle of winter.\u003c\/p\u003e\n\n\u003ch3\u003eOur commissioning, step by step\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eCheck of the supply voltage within the 540 to 630 V range and of the phase order, watched by the phase monitor.\u003c\/li\u003e\n\u003cli\u003eCheck of the clearances required by YORK: 72 in. clear above the unit, 36 in. on the front, back and left sides, and 12 in. on the right side.\u003c\/li\u003e\n\u003cli\u003eAdjustment of the belt drive and of the IntelliSpeed speeds to the actual static pressure of your ducts, to deliver the intended airflow.\u003c\/li\u003e\n\u003cli\u003eSetup of the economizer: changeover setpoint for free cooling mode and minimum fresh air position.\u003c\/li\u003e\n\u003cli\u003eProgramming of the Smart Equipment control: thermostat or zone sensor, fan delays, compressor lockout on low outdoor temperature if needed.\u003c\/li\u003e\n\u003cli\u003eExtraction of the start-up report through the USB port and a walkthrough for your maintenance manager.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003ePlanned maintenance suited to an industrial setting\u003c\/h3\u003e\n\u003ch4\u003eFilters and air quality\u003c\/h4\u003e\n\u003cp\u003eThe unit uses four 24 x 20 x 2 in. filters. In a dusty environment, 2 in. MERV 8 or 4 in. MERV 13 pleated filters can replace the disposable filters, and a dirty filter switch is available to signal an abnormal pressure drop.\u003c\/p\u003e\n\u003ch4\u003eCoils, fan and condensate\u003c\/h4\u003e\n\u003cp\u003eService windows in the condenser walls allow the coils to be cleaned without heavy disassembly. The motor and fan assembly slides out of the cabinet, and the non-corrosive condensate pan is pulled out from the back. The hinged panels open without tools, then are screwed shut again after each visit to block access by unauthorized people.\u003c\/p\u003e\n\u003ch4\u003eDiagnostics\u003c\/h4\u003e\n\u003cp\u003eAt every visit, we review the fault history recorded by the Smart Equipment board. Thanks to the two independent refrigerant circuits, a fault on one circuit locks out only the compressor tied to it, after three trips in two hours.\u003c\/p\u003e\n\n\u003ch3\u003eAccessories that earn their place in an industrial setting\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCoil guard and hail guard kit.\u003c\/li\u003e\n\u003cli\u003eSmoke detectors for the supply or return air.\u003c\/li\u003e\n\u003cli\u003eCO2 sensor, which drives the economizer open when the level goes above the preset limit.\u003c\/li\u003e\n\u003cli\u003eBurglar bars for the duct openings of the roof curb.\u003c\/li\u003e\n\u003cli\u003eRoof curb of 8 in. or 14 in., or transition curb for an older Sunline unit of 7.5 to 12.5 tons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eYour industrial project in the hands of our teams\u003c\/h2\u003e\n\u003cp\u003eWe start with a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, which surveys the loads, the condition of the ducts, the 575 V distribution and the access to the roof or to the pad. We confirm the sizing, plan the crane lift using the base rails with their lifting holes, install the unit with our own teams and carry out the commissioning described above. A planned maintenance contract then helps keep the unit reliable, season after season.\u003c\/p\u003e\n\u003cp\u003eAs an HVAC contractor, AirGreen serves the industrial parks and commercial buildings of Montreal, Laval, Longueuil, the North Shore and the South Shore, with fast and efficient service calls. Call us at 514 316-2973 or write to us through the form on airgreen.ca to schedule your visit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367217410340,"sku":"XP090C00R5B1BAA1A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_PRO_00_PRINCIPALE_e5f8132a-afbd-4131-a438-869be02b7882.png?v=1790963232"},{"product_id":"thermopompe-monobloc-york-xp-de-10-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XP 10 Ton 575V | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eTen tons and 3,300 CFM for large commercial and industrial volumes\u003c\/h2\u003e\n\u003cp\u003eA showroom with a high ceiling, an open-plan retail store, a manufacturing shop or a shipping area have one thing in common: a lot of air to move and a load that varies with the hour, the season and the activity. This 10 ton YORK Sun Pro packaged heat pump, supplied at \u003cstrong\u003e575 V three-phase\u003c\/strong\u003e, delivers a nominal airflow of 3,300 CFM and splits its capacity over \u003cstrong\u003etwo stages of cooling\u003c\/strong\u003e. AirGreen sizes it, installs it and maintains it for the buildings of Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eFigures that match large spaces\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal capacity: 10 tons (120,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 111,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 102,000 BTU\/h, COP of 3.5\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 59,000 BTU\/h, COP of 2.25\u003c\/li\u003e\n\u003cli\u003eEER of 11.0 and IEER of 14.5\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 3,300 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 575 V, three-phase, 60 Hz (applied voltage from 540 to 630 V)\u003c\/li\u003e\n\u003cli\u003eTwo scroll compressors on independent circuits, steps of 50% and 100%\u003c\/li\u003e\n\u003cli\u003eR-410A refrigerant\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 59 x 89 x 50.75 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 1,135 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270): 83 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTwo stages for a large volume that does not fill up all at once\u003c\/h3\u003e\n\u003cp\u003eA large space does not always reach its full load as soon as it opens. In the morning, the first compressor, which on its own provides half the capacity, can be enough; the second starts when foot traffic, lighting and solar gains add up. With the \u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e on this model, the supply fan slows down when only the first stage is running, then speeds up on the second. It is this part-load operation that the IEER of 14.5 measures, while the EER of 11.0 describes the efficiency at full load. Like every unit of 6 tons and more, this model has no SEER rating.\u003c\/p\u003e\n\u003cp\u003eThe two refrigerant circuits are independent and monitored separately by the control board, which follows the state of the high and low pressure switches of each one. A lead-lag option spreads the run hours between the two compressors.\u003c\/p\u003e\n\n\u003ch3\u003eA packaged unit that thinks big without taking up more room\u003c\/h3\u003e\n\u003cp\u003eThe principle remains that of any \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e, with compressors, coils, fans and control brought together in a single outdoor cabinet, connected to the building's ducts. The 10 ton version keeps the same 59 x 89 x 50.75 in. cabinet as the Sun Pro models from 6.5 to 8.5 tons, and the roof curb is common to the whole series. The outdoor coil, with its circuits on separate faces, offers 29 ft² of surface; the indoor coil, with four rows, offers 13.2. Two 24 in. direct-drive condenser fans push the heat upward.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-410A\u003c\/strong\u003e, the previous-generation refrigerant, is a proven technology. The unit is delivered charged, wired, piped and factory tested, which shortens the work in the field.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the XP120C00R5B1BAA1A2 model includes\u003c\/h3\u003e\n\u003cp\u003eDecoded from the YORK nomenclature, this number corresponds to the following configuration:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntelliSpeed variable-speed drive with a high static pressure belt drive (3 HP motor).\u003c\/li\u003e\n\u003cli\u003eEconomizer with a barometric relief damper, able to bring in up to 100% outdoor air.\u003c\/li\u003e\n\u003cli\u003ePhase monitor and stand-alone Smart Equipment control.\u003c\/li\u003e\n\u003cli\u003eStandard coils and 2 in. disposable filters.\u003c\/li\u003e\n\u003cli\u003eNo factory service option and no factory-installed electric heat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivering 3,300 CFM: our design advice\u003c\/h3\u003e\n\u003cp\u003eA high airflow only gives good comfort if the duct system keeps up. The high static pressure drive suits long duct systems or ones loaded with accessories, and the belt is adjusted precisely to the needs of the job. The unit connects from the bottom or from the side; the factory covers simply move over, with no cutting. In a large occupied volume, the economizer with its low-leakage dampers (AMCA 511, class 1A) brings in fresh air and free cooling in the shoulder seasons, and a 575 V powered exhaust fan can be added when the fresh air brought in has to be exhausted. A CO2 sensor can also drive the economizer open when occupancy pushes the level up.\u003c\/p\u003e\n\n\u003ch3\u003eHeating: heat pump first, electric backup heat when needed\u003c\/h3\u003e\n\u003cp\u003eIn heating mode, the heat pump delivers 102,000 BTU\/h at 47 °F and 59,000 BTU\/h at 17 °F. For the colder periods, YORK offers for this model electric heat kits of 18, 24, 36 or 54 kW in 575 V, with nickel-chrome elements, an automatic-reset temperature limit and single point power supply. The heat section slides out of the unit for maintenance. We choose the kit from the actual heat loss of the building and the capacity of your electrical distribution.\u003c\/p\u003e\n\n\u003ch3\u003eControls and protections worthy of the investment\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e board monitors the outdoor, supply and return air temperatures through factory-installed sensors, as well as the supply voltage, in order to protect the unit during a voltage drop. Its LCD screen shows the operating status and the fault codes, and its USB port keeps the fault history, allows software updates and produces the start-up reports. A low limit function keeps the supply air from dropping below a programmable setpoint when cooling is needed in cold weather. On the refrigerant side, freeze thermostats on the suction line, solid core filter driers, pressure switches and crankcase heaters protect the installation. For remote monitoring, a MAP (Mobile Access Portal) gateway is available as an accessory for this control.\u003c\/p\u003e\n\n\u003ch3\u003eLifting and connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFull perimeter base rails with lifting holes for the crane and forklift slots on three sides.\u003c\/li\u003e\n\u003cli\u003eRoof curb of 8 in. or 14 in. with an insulated deck, or a 10 in. transition curb to take over the spot of a Sunline unit of 7.5 to 12.5 tons.\u003c\/li\u003e\n\u003cli\u003eMinimum clearances: 12 in. on the right, 36 in. on the left, at the front and at the back, and 72 in. above so that nothing blocks the condenser air discharge.\u003c\/li\u003e\n\u003cli\u003eDisconnect switch to be planned in the field, since this model has no factory service option.\u003c\/li\u003e\n\u003cli\u003eElectrical entry from the side or from underneath, with separate openings for the control wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTrust your 10 ton project to AirGreen\u003c\/h2\u003e\n\u003cp\u003eA unit of this size is chosen with a serious load calculation. During the \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, we measure the volume, note the occupancy, examine the existing ducts and the 575 V distribution, then we check the access for the crane. Our teams install the unit, balance the airflow, set up the economizer, the IntelliSpeed drive and the Smart Equipment control, then take care of the planned maintenance: filters, coils, belt and a read of the fault history.\u003c\/p\u003e\n\u003cp\u003eAs an HVAC contractor, AirGreen responds quickly in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Reach us at 514 316-2973 or through the form on airgreen.ca to schedule your visit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367217836324,"sku":"XP120C00R5B1BAA1A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_PRO_00_PRINCIPALE_66fabb75-e3ab-4cab-ae6e-23d492963d33.png?v=1790963215"},{"product_id":"thermopompe-monobloc-york-xqe-de-4-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XQE 4 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eA 4 ton Sun Core unit that fits the roof curb already in place\u003c\/h2\u003e\n\u003cp\u003eYour business is fed with 208\/230 V three-phase power and you are looking for a reliable rooftop unit to cool in summer and heat in winter. The 4 ton YORK Sun Core XQE (48,000 BTU\/h nominal) is a \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e on R-410A, rated 13.4 SEER2, driven by the Smart Equipment control and built on a full-length base that fits many existing roof curbs. AirGreen, an HVAC contractor from Montreal, supplies and installs it for businesses in Laval, in Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\u003ch3\u003eDesigned for the replacement market\u003c\/h3\u003e\n\u003cp\u003eYORK designed the Sun Core line with the replacement market in mind: its \u003cstrong\u003eperimeter base rail\u003c\/strong\u003e fits many roof curbs already in place. The rails, made of heavier steel, are shaped to stand up to transport and lifting. They surround the unit on four sides, with holes for lifting shackles and openings for the forklift.\u003c\/p\u003e\n\u003cp\u003eSince compatibility depends on the existing curb, we always measure it during the estimate. If a new curb is preferable, YORK offers 14 or 24 in. curbs, shipped knocked down, with insulated decking and a wood nailer strip around the full perimeter. They carry the entire weight of the unit, and the ducts can be attached to them before the unit is set in place.\u003c\/p\u003e\n\u003ch3\u003eWhat \"packaged\" means for a business\u003c\/h3\u003e\n\u003cp\u003eIn a packaged unit, the whole system sits in a single outdoor cabinet: scroll compressor, copper and aluminum coils, fans, filters and control. Nothing takes up your sales floor or your stockroom. The unit connects to the supply and return ducts and, thanks to the heat pump mode, it heats in winter and cools in summer.\u003c\/p\u003e\n\u003cp\u003eConfigured at the factory for bottom supply and return, it converts in the field to horizontal connections. A mixed arrangement is also possible: bottom supply and horizontal return, or the other way around. This flexibility helps reuse the existing ducts.\u003c\/p\u003e\n\u003ch3\u003ePerformance rated under the SEER2 standard\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated capacity:\u003c\/strong\u003e 4 tons (48,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI net cooling:\u003c\/strong\u003e 48,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating at 47 °F (8.3 °C):\u003c\/strong\u003e 46,700 BTU\/h, COP of 3.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating at 17 °F (-8.3 °C):\u003c\/strong\u003e 26,400 BTU\/h, COP of 2.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2 ratings:\u003c\/strong\u003e SEER2 13.4, HSPF2 6.7 and EER2 12.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings under the previous standard:\u003c\/strong\u003e SEER 14.5 and HSPF 8.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated airflow:\u003c\/strong\u003e 1,550 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 208\/230 V, three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (width x length x height):\u003c\/strong\u003e 48.9 x 74.1 x 40.6 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating weight:\u003c\/strong\u003e 628 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor sound level (AHRI 270):\u003c\/strong\u003e 78.4 dB(A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R-410A, the previous-generation refrigerant with proven technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSmart Equipment: the control at the heart of the unit\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control comes standard on the XQE. It works with a conventional 24 V thermostat, a zone sensor or, with the communication card offered as a factory option, a building management system on BACnet MS\/TP, Modbus or N2. Three temperature sensors, installed at the factory, read supply air, return air and outdoor air.\u003c\/p\u003e\n\u003cp\u003eThe LCD display, with its navigation joystick, shows unit status, measured temperatures and alarms. The USB port allows data logging, review of current and previous faults, software updates and energy consumption tracking. The control also monitors the supply voltage and protects the unit in the event of a voltage drop. Finally, it applies a short-cycle delay and programmable fan delays, separate for heating and cooling.\u003c\/p\u003e\n\u003cp\u003eOffered as a factory option or as an accessory, the fault detection and diagnostics (FDD) module continuously monitors the pressures and temperatures of the refrigerant circuit. It raises an alarm when the unit is not running at its best, and its data can be reached remotely through the Mobile Access Portal gateway.\u003c\/p\u003e\n\u003ch3\u003eSimple, rugged mechanics\u003c\/h3\u003e\n\u003cp\u003eOn the 3 to 5 ton models, YORK uses a single refrigeration circuit and a single \u003cstrong\u003escroll compressor\u003c\/strong\u003e. The scroll has a simple internal design, with fewer moving parts, which makes it quiet, reliable and easy to service. The compressor is internally protected, in particular against liquid-induced damage. Each circuit includes a filter-drier and high and low pressure switches, while sensors on the suction line guard against liquid floodback, loss of charge and coil frosting.\u003c\/p\u003e\n\u003cp\u003eThe outdoor fan, dynamically balanced, contributes to the quieter operation of the unit. The embossed top adds rigidity to the cabinet, and the powder-coat finish withstands 750 hours of salt spray exposure. YORK tests and rates these units in cooling up to 125 °F (52 °C) outdoors. At the other end, the built-in low ambient control allows cooling down to 40 °F (4 °C) with no additional component.\u003c\/p\u003e\n\u003ch3\u003eVentilation and air quality\u003c\/h3\u003e\n\u003cp\u003eThe XQE comes with four 2 in. disposable filters (16 x 16 x 2 in.) rated MERV 4. MERV 8 or MERV 13 filters install easily through the filter access panel, which opens without tools. For fresh air, YORK offers economizers installed at the factory or in the field, able to bring in up to 100% outdoor air, along with manual adjustable dampers from 0 to 35% or from 0 to 100% and a motorized damper. The control accepts a CO2 sensor for ventilation based on occupancy.\u003c\/p\u003e\n\u003ch3\u003eElectric backup heat\u003c\/h3\u003e\n\u003cp\u003eThe heat pump delivers 46,700 BTU\/h at 47 °F (8.3 °C) and 26,400 BTU\/h at 17 °F (-8.3 °C). For colder days, the electric heat for the XQE is installed in the field. On 208\/230 V three-phase, the YORK guide offers 6.5, 10.5 and 16 kW kits at 230 V, which give 4.9, 7.9 and 12 kW respectively at 208 V. The required hardware and connectors are supplied with each kit. If you go with the non-fused disconnect offered from the factory (60 or 100 A), we check that it suits the kit you choose.\u003c\/p\u003e\n\u003ch3\u003ePoints to settle before ordering\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMeasure the existing roof curb and the position of the supply and return openings.\u003c\/li\u003e\n\u003cli\u003eCheck the three-phase supply, which must stay between 187 and 252 V according to the YORK guide.\u003c\/li\u003e\n\u003cli\u003eMinimum clearances: 12 in. on the left and 18 in. on the right, 36 in. at the front, 72 in. clear above for air discharge, and 18 in. at the rear, raised to 36 in. with an economizer or a power exhaust.\u003c\/li\u003e\n\u003cli\u003eConsider the through-the-base electrical connection kit, which brings the power in without any additional roof penetration.\u003c\/li\u003e\n\u003cli\u003ePlan the crane lift using the holes provided in the base rails.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eAirGreen, your contractor for commercial roofs\u003c\/h2\u003e\n\u003cp\u003eChoosing the right rooftop unit starts with measuring properly. During our \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, we check the curb, the ducts, the electrical service and the heating needs of your business. We size the unit and the backup kit, then our crews take care of the lifting, the installation, the commissioning and the periodic maintenance.\u003c\/p\u003e\n\u003cp\u003eAirGreen serves Montreal, Laval, Longueuil, the North Shore and the South Shore. For your 4 ton YORK Sun Core XQE packaged heat pump, reach our team at 514\u0026nbsp;316-2973 or request your estimate online at airgreen.ca. We will call you back quickly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367217869092,"sku":"XQE05A2C1AA1B111A3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_ff7e6a46-f4ee-46b6-b771-403d11977b52.png?v=1790963197"},{"product_id":"thermopompe-monobloc-york-xqe-de-5-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XQE 5 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eA roof that is hard to reach: 5 tons built for quick maintenance\u003c\/h2\u003e\n\u003cp\u003eOn many buildings, the roof is reached by a ladder and a hatch, and every service call has to be short and well prepared. The 5 ton YORK Sun Core XQE (60,000 BTU\/h nominal) answers that reality: a \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e on R-410A, fed in 208\/230 V three-phase, in a compact cabinet with wide service access and filters that change without a tool. AirGreen, an HVAC contractor in Montreal, installs and maintains it in Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\u003ch3\u003eWhen every trip to the roof counts\u003c\/h3\u003e\n\u003cp\u003eLimited access does not change what a rooftop unit needs in maintenance: filters, coils, belt, reading the pressures and checking the protections. It does change what each visit costs in time. Hence the value of a unit where everything sits in the same place and where the routine steps go quickly, without taking apart more than necessary.\u003c\/p\u003e\n\u003ch3\u003eA compact, small-footprint cabinet\u003c\/h3\u003e\n\u003cp\u003eThe 5 ton XQE uses what the Sun Core line calls the \u003cstrong\u003esmall footprint\u003c\/strong\u003e cabinet: 48.9 in. wide, 74.1 in. long and 40.6 in. high, for an operating weight of 627 lb. The one-piece top panel is embossed to stiffen the cabinet. The base rails run around all four sides of the unit and are drilled to take lifting shackles and the forks of a lift truck. A single crane lift is enough to set it in place.\u003c\/p\u003e\n\u003ch3\u003eService access that is wide and well thought out\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge access panels:\u003c\/strong\u003e the indoor blower, rigidly mounted and dynamically balanced, is reached through wide panels that come off easily.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in handles:\u003c\/strong\u003e the panels of the control box, of the indoor blower, of its motor and of the compressor have handles in UV-treated composite, permanently fixed and recessed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaceable collars:\u003c\/strong\u003e the panel screws thread into heat-resistant composite collars that are easy to replace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure readings:\u003c\/strong\u003e a port closed by a removable plug lets us connect the gauges and read the head pressure without removing the compressor panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor fan:\u003c\/strong\u003e direct drive, mounted to the grille, it is quick to service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHinged doors:\u003c\/strong\u003e offered as a factory option, they save removing the panels, and therefore misplacing them or damaging the roof covering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFilters that change without a tool\u003c\/h3\u003e\n\u003cp\u003eThe filter access panel, installed at the factory, opens without a tool. The four 2 in. disposable filters are all the same size, 16 x 16 x 2 in.: a single dimension to carry up to the roof. Supplied in MERV 4, they can give way to MERV 8 or MERV 13 filters, slid in through the same panel. If the unit receives a horizontal-flow economizer, YORK offers a hinged filter access panel designed for that configuration.\u003c\/p\u003e\n\u003ch3\u003eDiagnosing quickly, on site or remotely\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control, standard, shows on its LCD display the operating status, the air temperatures (supply, return, outdoor) and the alarm codes. The last five codes are held in non-volatile memory, which a power failure does not erase. Through the USB port, the technician downloads the data log and the start-up reports. Before locking out the compressor, the control waits for three trips of the same protection within two hours, which cuts down on needless calls.\u003c\/p\u003e\n\u003cp\u003eTo limit the trips, two factory options deserve your attention: the BACnet MS\/TP, Modbus or N2 communication card to link the unit to your building management system, and the FDD module, which monitors the refrigerant circuit and whose data can be consulted remotely through the Mobile Access Portal gateway.\u003c\/p\u003e\n\u003ch3\u003eFewer unplanned visits\u003c\/h3\u003e\n\u003cp\u003eOn a roof that is hard to reach, the best visit is the one you do not have to make. The \u003cstrong\u003escroll compressor\u003c\/strong\u003e of the XQE has a simple internal design and internal protection that shields it from liquid slugging. The control monitors the supply voltage and protects the unit during a voltage drop. Every unit goes through an automated run test on the assembly line, and YORK keeps the data from that test at the factory. The galvanized steel cabinet, finished with a powder paint proven through 750 hours of salt spray, is built to the UL 1995 standard, which includes a rain resistance test.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eXQE 5 ton, 208\/230 V three-phase\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e5 tons (60,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e57,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e30,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 ratings\u003c\/td\u003e\n\u003ctd\u003eSEER2 13.4, HSPF2 6.7, EER2 11.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRatings under the former standard\u003c\/td\u003e\n\u003ctd\u003eSEER 14.5, HSPF 8.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e1,640 CFM (ft³\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, three-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (width x length x height)\u003c\/td\u003e\n\u003ctd\u003e48.9 x 74.1 x 40.6 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e627 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor sound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e77.8 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-410A (previous generation, proven technology)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eThe packaged unit: a single machine to maintain\u003c\/h3\u003e\n\u003cp\u003eA packaged unit brings together in a single outdoor cabinet the scroll compressor, the indoor coil, the outdoor coil, the fans, the filters and the control, all connected to the building's ducts. For a roof that is hard to reach, that is a clear advantage: one visit covers the whole system, and no indoor unit is hidden in a ceiling. In the field, what is left is to connect the ducts, the power, the control wiring and the condensate drain (3\/4 in. NPT fitting, from underneath or from the side of the pan).\u003c\/p\u003e\n\u003ch3\u003eHeating and electric backup\u003c\/h3\u003e\n\u003cp\u003eThe heat pump delivers 54,500 BTU\/h at 47 °F (8.3 °C) and 30,600 BTU\/h at 17 °F (-8.3 °C). To top up the heat in very cold weather, YORK offers field-installed \u003cstrong\u003eelectric heat\u003c\/strong\u003e kits: 6.5, 10.5 or 16 kW at 230 V, that is 4.9, 7.9 or 12 kW at 208 V. We choose the kit according to the heat loss of the building.\u003c\/p\u003e\n\u003ch3\u003ePlanning the lift and the clearances\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eBook the crane and check the lift path over the building.\u003c\/li\u003e\n\u003cli\u003eLeave 36 in. at the front and 72 in. above the unit.\u003c\/li\u003e\n\u003cli\u003eAllow 18 in. on the right, 12 in. on the left and 18 in. at the back, or 36 in. with an economizer or a powered exhaust.\u003c\/li\u003e\n\u003cli\u003eBring the power in through the base with the watertight connection kit, without an additional penetration in the roof.\u003c\/li\u003e\n\u003cli\u003eConsider the louvred hail guard, which protects the fins of the outdoor coil.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eOne point of contact for your rooftop unit\u003c\/h2\u003e\n\u003cp\u003eWe know that a roof that is hard to reach calls for preparation. Our \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e includes a survey of the roof access, the curb, the ducts and the electrical entrance. We then size the unit and the electric backup, and our crews coordinate the lift, carry out the installation and the commissioning, and handle the scheduled maintenance.\u003c\/p\u003e\n\u003cp\u003eOur crews travel to Montreal, Laval, Longueuil, the North Shore and the South Shore. Call 514 316-2973 or write to us from the form on airgreen.ca: we will schedule your visit quickly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367218360612,"sku":"XQE06A2B1AA1A111A3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_14a5638c-ce50-4772-a8b0-f350b3f29b67.png?v=1790963173"},{"product_id":"thermopompe-monobloc-york-xqe-de-5-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XQE 5 Ton 575V | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eComfort for factory offices, on a 575 V supply\u003c\/h2\u003e\n\u003cp\u003eIn a factory or a warehouse, the production floor has its own systems, but the offices, the cafeteria and the control room need steady comfort, summer and winter. The 5 ton YORK Sun Core XQE (60,000 BTU\/h nominal) in its 575 V three-phase version is an R-410A \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e that connects directly to the electrical distribution of your industrial building. AirGreen, an HVAC contractor in Montreal, installs it in the industrial sectors of Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eThree spaces, three ways to use the same unit\u003c\/h3\u003e\n\u003ch4\u003eThe offices\u003c\/h4\u003e\n\u003cp\u003eOccupied on a fixed schedule, offices benefit from a programmable thermostat with an occupancy schedule. The Smart Equipment control accepts a conventional 24 V thermostat or a zone sensor, and the fan delays are adjusted independently for heating and for cooling.\u003c\/p\u003e\n\u003ch4\u003eThe cafeteria\u003c\/h4\u003e\n\u003cp\u003eAt mealtime, occupancy climbs all at once. An \u003cstrong\u003eeconomizer\u003c\/strong\u003e can bring in up to 100% outdoor air, and a CO2 sensor wired to the control allows ventilation based on demand. YORK also offers powered exhaust fans in 575 V, which push out the excess air when the economizer is open.\u003c\/p\u003e\n\u003ch4\u003eThe control room\u003c\/h4\u003e\n\u003cp\u003eThe equipment in it gives off heat in every season. Thanks to the built-in low-ambient control, the XQE cools down to 40 °F (4 °C) outdoors, with no added component. To go lower, YORK offers a head pressure control kit, installed in the field, that varies the airflow through the outdoor coil. If the room houses critical equipment, we confirm the application with you before choosing the unit.\u003c\/p\u003e\n\u003ch3\u003eA direct 575 V supply\u003c\/h3\u003e\n\u003cp\u003eBuilt at the factory for 575 V three-phase (60 Hz), the unit accepts, according to the YORK guide, an applied voltage between 540 and 630 V. For backup heat, two electric kits of 13.8 kW and 23 kW are offered in 575 V for this model. They are installed in the field, with the hardware and connectors supplied.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNon-fused disconnect switch of 60 or 100 A offered as a factory option, with its rating checked against the heat kit selected\u003c\/li\u003e\n\u003cli\u003eThrough-the-base electrical entry kit, which avoids drilling the roof one more time\u003c\/li\u003e\n\u003cli\u003e120 V receptacle protected by a ground-fault circuit interrupter, offered as a factory option, powered by the unit or wired in the field\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHeating the spaces in winter\u003c\/h3\u003e\n\u003cp\u003eIn heat pump mode, the XQE delivers 54,500 BTU\/h when it is 47 °F (8.3 °C) outdoors, and still 30,600 BTU\/h at 17 °F (-8.3 °C). The capacity of a heat pump drops as it gets colder: the 13.8 kW or 23 kW kit then covers the difference. We choose it from the heat loss of the offices and the cafeteria, taking into account the dock doors or the partitions that separate them from the warehouse.\u003c\/p\u003e\n\u003ch3\u003eFiltration in a dusty environment\u003c\/h3\u003e\n\u003cp\u003eAs standard, the unit takes four 16 x 16 x 2 in. MERV 4 disposable filters. Where production dust travels, we can move up to a MERV 8 or MERV 13 rating, installed through the tool-less filter access panel. We then match the replacement interval to the reality of your building.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal capacity: 5 tons (60,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 57,400 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 54,500 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 30,600 BTU\/h\u003c\/li\u003e\n\u003cli\u003eEfficiency: SEER2 13.4, HSPF2 6.7 and EER2 11.9 (SEER 14.5 and HSPF 8.25 under the previous standard)\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 1,640 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 575 V, three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 48.9 x 74.1 x 40.6 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 627 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270): 77.8 dB(A)\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-410A (previous-generation refrigerant, proven technology)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBuilt to last in an industrial environment\u003c\/h3\u003e\n\u003cp\u003eOn the galvanized steel of the cabinet, YORK applies a powder paint that has passed the 750 hour salt spray test of the ASTM B117 standard. As an option, an epoxy polymer \u003cstrong\u003eE-Coat\u003c\/strong\u003e coating protects the indoor and outdoor coils against corrosion and limits galvanic action between aluminum and copper. The standard coils are leak checked at 150 psig and pressure tested, at 450 psig for the indoor coil and at 650 psig for the outdoor coil.\u003c\/p\u003e\n\u003cp\u003eAssembled in Norman, Oklahoma, in an ISO 9001 registered plant, every unit goes through a fully automated run test at the end of the line. YORK also puts it through a vibration test to the ASTM D4169 standard to make shipping more reliable, and it is certified to the CSA C22.2 No. 236 (UL 1995) standard. Supply air or return air smoke detectors, which stop the unit when smoke is present, and burglar bars for the duct openings round out the offering.\u003c\/p\u003e\n\u003ch3\u003eWhy a packaged heat pump in an industrial building\u003c\/h3\u003e\n\u003cp\u003eThe packaged heat pump holds the whole system in a single cabinet set on the roof: scroll compressor, coils, fans, filters and control. The ducts run down to the offices, the cafeteria or the control room, with no refrigerant line inside the plant and no unit hanging above the workstations. The same unit cools in summer and heats in winter.\u003c\/p\u003e\n\u003ch3\u003eSmart Equipment and building integration\u003c\/h3\u003e\n\u003cp\u003eAs standard, the \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control provides an LCD screen, a USB port for data logging and updates, as well as three factory-installed sensors (supply air, return air and outdoor air). If your plant has a building management system, a communication card (BACnet MS\/TP, Modbus or N2), offered as a factory option, lets you follow the unit from that system. The FDD module, offered as an option, watches the refrigerant circuit and reports any abnormal operation. Another protection that is useful on an industrial electrical network: the control detects voltage drops and puts the unit out of harm's way.\u003c\/p\u003e\n\u003ch3\u003eSteps of a 575 V project\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVisit of the spaces to be served and load calculation for each space.\u003c\/li\u003e\n\u003cli\u003eVerification of the 575 V circuit, the disconnect switch and the backup heat kit.\u003c\/li\u003e\n\u003cli\u003eChoice of the roof curb: YORK curbs of 14 or 24 in., with insulated decks, shipped knocked down.\u003c\/li\u003e\n\u003cli\u003eCrane lift of the 627 lb unit, by the lifting points on the base rails.\u003c\/li\u003e\n\u003cli\u003eClearances: 36 in. at the front, 12 in. on the left, 18 in. on the right, 72 in. above and, at the back, 18 in. or 36 in. if the unit takes an economizer or a powered exhaust fan.\u003c\/li\u003e\n\u003cli\u003eStart-up and schedule programming with your team.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eAirGreen supports industrial buildings\u003c\/h2\u003e\n\u003cp\u003eWe sell and install rooftop units for the factories, warehouses and businesses of the greater Montreal area: Laval, Longueuil, the North Shore and the South Shore. The starting point: a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, during which we visit the offices, the cafeteria and the control room, then check the 575 V service and the roof. We then set the size of the unit and of the electric backup heat, and our teams take care of the installation, the start-up and the maintenance.\u003c\/p\u003e\n\u003cp\u003eTo start your project, call 514 316-2973 or fill out our form on airgreen.ca: a member of our team will get back to you quickly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367218393380,"sku":"XQE06A5C1AA1B111A3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_934f7da3-1441-492b-b530-5a1ffd30939c.png?v=1790963156"},{"product_id":"thermopompe-monobloc-york-xye-de-6-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XYE 6 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eMoving up to 6 tons without giving up comfort on quiet days\u003c\/h2\u003e\n\u003cp\u003eWhen a commercial space goes beyond what a 5 ton unit can cover, it is tempting to go bigger and accept a unit that starts and stops constantly on mild days. This 6 ton YORK Sun Core XYE packaged heat pump avoids that compromise: its \u003cstrong\u003etwo-stage scroll compressor\u003c\/strong\u003e works at 67% or at 100% of its capacity depending on demand, and its \u003cstrong\u003eIEER of 16.5\u003c\/strong\u003e shows its performance at part load. For a large store, open-plan offices, a clinic or a training studio fed in 208\/230 V three-phase, AirGreen offers and installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eTwo stages in a single compressor: 67% or 100%, depending on demand\u003c\/h3\u003e\n\u003cp\u003eIn the XYE line, the 3 to 5 ton models have only one cooling stage. The 6 ton is the first to offer two, through a single two-stage scroll compressor. When the load is moderate, it runs at 67% of its capacity rather than swinging between a full stop and full output; at peak hours, it steps up to 100%. The unit also has two 22 in. two-speed outdoor fans.\u003c\/p\u003e\n\u003cp\u003eThis behaviour explains the gap between the two efficiency ratings. The \u003cstrong\u003eEER of 12.0\u003c\/strong\u003e measures performance at full load; the IEER of 16.5, obtained with the IntelliSpeed drive, takes part-load operation into account. Like every unit of 6 tons and up, the XYEA7 is rated in EER and IEER, and not in SEER or HSPF.\u003c\/p\u003e\n\n\u003ch3\u003eA packaged heat pump in the large Sun Core cabinet\u003c\/h3\u003e\n\u003cp\u003eThe principle does not change: a \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e brings compressor, coils, fans and control together in a single outdoor cabinet, set on the roof or on the ground and connected to the building's ducts. It cools in summer and heats by heat pump the rest of the year. What changes at 6 tons is the size: the XYEA7 moves up to the large Sun Core cabinet of 61.7 x 87.2 in., in its low 40.6 in. version, and it shares the roof curb of the 7.5 to 10 ton models.\u003c\/p\u003e\n\u003cp\u003eThe XYE series is the high-efficiency version of the Sun Core line. It uses \u003cstrong\u003eR-410A\u003c\/strong\u003e, the previous generation refrigerant: a proven technology that technicians know well.\u003c\/p\u003e\n\n\u003ch3\u003eThe XYEA7 figures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal capacity: 6 tons (72,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 70,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 67,000 BTU\/h, COP of 3.4\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 38,000 BTU\/h, COP of 2.4\u003c\/li\u003e\n\u003cli\u003eEER of 12.0 and IEER of 16.5\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 2,440 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V, three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eCompressor: 1 two-stage scroll (67% \/ 100%)\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 61.7 x 87.2 x 40.6 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 898 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270): 83 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat the XYEA7A2B3AA1C111A2 configuration includes\u003c\/h3\u003e\n\u003cp\u003eRead against the nomenclature of the Sun Core technical guide, this model number describes the following equipment:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBelt-driven indoor blower, medium static pressure option.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e, which adjusts the supply fan speed according to the compressor or heating stage that is running.\u003c\/li\u003e\n\u003cli\u003eFactory-installed enthalpy economizer.\u003c\/li\u003e\n\u003cli\u003eSmart Equipment control, with factory-installed supply, return and outdoor air sensors.\u003c\/li\u003e\n\u003cli\u003eStandard indoor and outdoor coils, without E-Coat coating.\u003c\/li\u003e\n\u003cli\u003eNo disconnect switch, no convenience outlet and no factory electric heat: these are added in the field as needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEnthalpy economizer and IntelliSpeed: fresh air at the right moment\u003c\/h3\u003e\n\u003cp\u003eThe economizer on this model does not simply measure the outdoor temperature: its enthalpy sensor allows free cooling when the enthalpy of the outdoor air, which accounts for its humidity, is below the setpoint. Its low-leakage dampers (AMCA 511, class 1A) admit up to 100% outdoor air, and a dual enthalpy kit, installed in the field, can add a reading on the return air. Meanwhile, the IntelliSpeed drive modulates the airflow, and the minimum position of the economizer remains configurable.\u003c\/p\u003e\n\n\u003ch3\u003eThe Sun Core details that make maintenance easier\u003c\/h3\u003e\n\u003ch4\u003eFilters reached without a tool\u003c\/h4\u003e\n\u003cp\u003eThe XYEA7 takes four 16 x 20 x 2 in. filters, supplied as disposable MERV 4. MERV 8 or MERV 13 filters slide in easily through the tool-free access panel, a sound choice for a clinic or busy offices.\u003c\/p\u003e\n\u003ch4\u003eCoils and refrigerant circuit\u003c\/h4\u003e\n\u003cp\u003eThe coils, in copper tube with aluminum fins, are fed by a thermostatic expansion valve (TXV). The outdoor coil, with three rows, offers 21 ft² of surface, and the indoor coil, with four rows, 8.9 ft². A drier on the liquid line, high and low pressure switches and sensors on the suction line, which protect against liquid return, loss of refrigerant and coil frosting, complete the package.\u003c\/p\u003e\n\u003ch4\u003eA control you can read\u003c\/h4\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e board shows on its LCD display the status of the unit, the temperatures and the fault codes. Its USB port serves the fault history, the updates and the start-up reports, and a short-cycle protection with a minimum run time spares the compressor.\u003c\/p\u003e\n\u003ch4\u003eA rugged build\u003c\/h4\u003e\n\u003cp\u003eAssembled in Norman, Oklahoma, the unit has an embossed top for rigidity and a powder paint rated for 750 hours of salt spray. Every unit is commissioned, configured and tested at the factory.\u003c\/p\u003e\n\n\u003ch3\u003ePlanning the installation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof curb:\u003c\/strong\u003e the YORK curbs for the large cabinet are the 1RC0457 (14 in.) and the 1RC0459 (24 in.). If the unit being replaced sat on a small-size curb, we check the fit on site and plan a new curb if needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e applied voltage from 187 to 252 V; the disconnect switch is planned for the field.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup heat:\u003c\/strong\u003e three field-installed kits are available for this model in 208\/230 V, from 6.5 to 24.8 kW at 230 V (4.9 to 18.6 kW at 208 V).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 72 in. above, 48 in. at the front, 36 in. at the back with an economizer, 18 in. on the right and 12 in. on the left.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e air openings convertible from vertical to horizontal, and a through-the-base electrical connection kit (1TB0404) offered to avoid another penetration in the roof.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eAirGreen guides you through the move to 6 tons\u003c\/h2\u003e\n\u003cp\u003eThe right choice between 5, 6 and 7.5 tons is made on site. During the \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, we calculate the load of your space, look at the ducts, the electrical service and the existing roof curb, then we give you a clear recommendation. Our crews install the unit, set up the economizer, the IntelliSpeed drive and the Smart Equipment control, and then provide scheduled maintenance.\u003c\/p\u003e\n\u003cp\u003eWhether your business is in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, our HVAC team works quickly and efficiently. Call 514 316-2973 or fill out the form on airgreen.ca to get your quote.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367218819364,"sku":"XYEA7A2B3AA1C111A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_6_A_10_TONNES_00_PRINCIPALE_b7ccc18b-fe25-43a2-87c8-db92b56ac6b8.png?v=1790963139"},{"product_id":"thermopompe-monobloc-york-xxe-de-7-5-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XXE 7.5 Ton 575V | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eWarehouse, workshop or reception hall: 7.5 tons in 575 V for large spaces\u003c\/h2\u003e\n\u003cp\u003eLarge spaces each have their own rhythm. A warehouse holds a fairly steady load, a workshop builds up the heat of its machines, and a reception hall goes in a few minutes from an empty room to a crowd of guests. The 7.5 ton YORK Sun Core XXE packaged heat pump answers these three situations with \u003cstrong\u003etwo scroll compressors\u003c\/strong\u003e, two stages of cooling and an \u003cstrong\u003eIEER of 15.1\u003c\/strong\u003e, on a \u003cstrong\u003e575 V three-phase\u003c\/strong\u003e supply. AirGreen installs it in the commercial and industrial buildings of Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eThree large spaces, three ways to benefit from two stages\u003c\/h3\u003e\n\u003ch4\u003eThe warehouse\u003c\/h4\u003e\n\u003cp\u003eWith low occupancy and moderate heat gains, the first compressor, that is half the capacity, can be enough. In the shoulder seasons, the economizer takes over with cool outdoor air when conditions allow it.\u003c\/p\u003e\n\u003ch4\u003eThe workshop\u003c\/h4\u003e\n\u003cp\u003eThe equipment, the lighting and the door openings make the load vary through the shift. The second compressor starts when the temperature climbs, then stops when demand comes back down.\u003c\/p\u003e\n\u003ch4\u003eThe reception hall\u003c\/h4\u003e\n\u003cp\u003eHere, the load changes all at once when the guests arrive. The two stages make it possible to cool the hall at partial capacity before the event, then to move to full capacity as it fills up.\u003c\/p\u003e\n\u003cp\u003eIn all three cases, the \u003cstrong\u003eEER of 11.5\u003c\/strong\u003e measures the efficiency at full load, while the IEER of 15.1, obtained with the IntelliSpeed drive, takes part-load operation into account. This 7.5 ton model is rated in EER and IEER, not in SEER.\u003c\/p\u003e\n\n\u003ch3\u003eA packaged unit on the roof, tied to the 575 V network\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e holds the whole system in a single outdoor cabinet: the two compressors, the coils, the fans and the control board. On the roof or on a pad, it connects to the supply and return ducts, cools in summer and heats by heat pump the rest of the year. In a building supplied at 575 V, it connects to the existing distribution, within an applied voltage range of 540 to 630 V according to the YORK guide. It runs on \u003cstrong\u003eR-410A\u003c\/strong\u003e, a previous-generation refrigerant and a proven technology, and each compressor feeds its own independent refrigerant circuit.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal capacity:\u003c\/strong\u003e 7.5 tons (90,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI net cooling:\u003c\/strong\u003e 90,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating at 47 °F (8.3 °C):\u003c\/strong\u003e 84,000 BTU\/h, COP of 3.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating at 17 °F (-8.3 °C):\u003c\/strong\u003e 49,000 BTU\/h, COP of 2.25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e EER of 11.5, IEER of 15.1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal airflow:\u003c\/strong\u003e 3,300 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 575 V, three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressors:\u003c\/strong\u003e 2 scroll, steps of 50% and 100%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (width x length x height):\u003c\/strong\u003e 61.7 x 87.2 x 48.6 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating weight:\u003c\/strong\u003e 976 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor sound level (AHRI 270):\u003c\/strong\u003e 83.2 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe XXE08A5B3AA1B111A2 configuration\u003c\/h3\u003e\n\u003cp\u003eAccording to the Sun Core nomenclature, this model is delivered with a medium static pressure belt-drive indoor fan, an \u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e, a dry bulb economizer, the Smart Equipment control and standard coils. It includes no convenience receptacle, no disconnect switch and no factory electric heat: those items are planned in the field, according to the needs of your building. The supply, return and outdoor air temperature sensors are installed at the factory.\u003c\/p\u003e\n\n\u003ch3\u003eEconomizer and variable-speed drive: fresh air managed precisely\u003c\/h3\u003e\n\u003cp\u003eThe dry bulb economizer turns on free cooling when the outdoor temperature drops below its setpoint. Its low-leakage dampers, certified AMCA 511 class 1A, can bring in up to 100% outdoor air, and single or dual enthalpy kits, installed in the field, can refine the changeover based on humidity. For a full reception hall or a workshop, a powered exhaust fan in 575 V, designed for the large cabinet, can be added. The IntelliSpeed drive, for its part, varies the speed of the supply fan according to the number of compressors or heating stages running.\u003c\/p\u003e\n\n\u003ch3\u003eHeating a large space in 575 V\u003c\/h3\u003e\n\u003cp\u003eThe heat pump delivers 84,000 BTU\/h at 47 °F and 49,000 BTU\/h at 17 °F. To make up the difference, the YORK electrical tables list two electric heat kits in 575 V for this model, of 17 kW and 34 kW, installed in the field. We choose the kit from the heat loss of your building and size the disconnect switch accordingly.\u003c\/p\u003e\n\n\u003ch3\u003eWhat to plan for at installation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof curb:\u003c\/strong\u003e rigid large cabinet curbs of 14 in. (1RC0457) or 24 in. (1RC0459), with an insulated deck. The full perimeter base rail was designed to fit many existing curbs, which we verify on site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifting:\u003c\/strong\u003e 976 lb in operation; the rails have holes for the lifting shackles and for the forks of a forklift.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e plan 48 in. in front of the unit, 36 in. behind (with an economizer), 18 in. on the right, 12 in. on the left and 72 in. clear above.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDucts:\u003c\/strong\u003e supply and return convertible from vertical to horizontal, including in a mixed configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e through-the-base connection kit (1TB0404) to bring in the power without another hole in the roof.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSimple maintenance, designed for technicians\u003c\/h3\u003e\n\u003cp\u003eThe four 20 x 20 x 2 in. filters are replaced through a tool-less access panel; they ship as MERV 4, and MERV 8 or MERV 13 filters can replace them. The two 22 in. direct-drive condenser fans are fastened to the grille, which speeds up their maintenance. The \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e board watches each circuit, shows the fault codes on its LCD screen and keeps the history, which can be read through its USB port. To go further, a fault detection and diagnostics (FDD) module on the refrigerant side is available as an accessory installed in the field.\u003c\/p\u003e\n\u003cp\u003eOn the reliability side, the board applies the three-trip rule: a pressure switch, the freeze protection or a low voltage must trip three times in two hours before the associated compressor is locked out, which avoids shutdowns for passing alarms. An anti-short-cycle timer, programmable minimum run times and independent fan delays for heating and cooling round out the protection. The cabinet, with its embossed top, receives a powder paint rated at 750 hours of salt spray.\u003c\/p\u003e\n\n\u003ch2\u003eAirGreen, from the estimate to the maintenance of your 7.5 ton unit\u003c\/h2\u003e\n\u003cp\u003eWe start with a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, which covers the space and how it is used, the condition of the ducts, the 575 V distribution and the roof access. We confirm the sizing, organize the lift, install the unit with our own teams and carry out the full commissioning, then we propose planned maintenance suited to your building.\u003c\/p\u003e\n\u003cp\u003eWhether your warehouse, your workshop or your reception hall is in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, our HVAC technicians respond quickly and efficiently. Call us at 514 316-2973 or use the form on airgreen.ca to schedule your visit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367218852132,"sku":"XXE08A5B3AA1B111A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_6_A_10_TONNES_00_PRINCIPALE_881316c7-31e8-4bd6-9b3a-14d9b3cd9fb2.png?v=1790963119"},{"product_id":"thermopompe-monobloc-york-xxe-de-10-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XXE 10 Ton 575V | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eGym, big-box store or multipurpose hall: 10 tons for very large volumes\u003c\/h2\u003e\n\u003cp\u003eA gym packed on a tournament night, a big-box store with endless aisles, a multipurpose hall that hosts in turn a banquet, an assembly and a sports activity: these spaces call for a lot of air, well distributed, and a reliable installation from the first to the last day of the season. The 10 ton YORK Sun Core XXE packaged heat pump, supplied at \u003cstrong\u003e575 V three-phase\u003c\/strong\u003e, moves a nominal airflow of \u003cstrong\u003e3,600 CFM\u003c\/strong\u003e and splits its capacity between \u003cstrong\u003etwo independent refrigerant circuits\u003c\/strong\u003e. AirGreen sizes it, installs it and maintains it for owners and property managers in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eTwo independent circuits, a safeguard for large volumes\u003c\/h3\u003e\n\u003cp\u003eEach of the two scroll compressors feeds its own refrigerant circuit, with its filter drier on the liquid line and its high and low pressure switches. The control board watches each safety device separately. If one of them trips three times in less than two hours, only the associated compressor is locked out and a fault message appears. For a gym or a hall where an event is planned, this architecture limits the effect of an isolated fault on the installation as a whole.\u003c\/p\u003e\n\u003cp\u003eThe two compressors also form two stages of cooling, at 50% and at 100% of the capacity. The \u003cstrong\u003eEER of 11.0\u003c\/strong\u003e describes the efficiency at full load, while the IEER of 14.6, obtained with the IntelliSpeed drive, takes part-load operation into account. Like the other units of 6 tons and more, this model is not rated in SEER.\u003c\/p\u003e\n\n\u003ch3\u003e3,600 CFM to distribute: high static pressure and IntelliSpeed\u003c\/h3\u003e\n\u003cp\u003eIn a very large volume, the ducts are often long and the grilles many. This model is fitted with the \u003cstrong\u003ehigh static pressure\u003c\/strong\u003e belt-drive indoor fan option, reserved for the three-phase models, with a motor of 5.25 BHP at most according to the guide. The IntelliSpeed drive varies the speed of the supply fan according to the number of compressors or heating stages running. The dry bulb economizer, with its AMCA 511 class 1A low-leakage dampers, can bring in up to 100% outdoor air, and the Smart Equipment control accepts a CO2 sensor in the space for ventilation based on occupancy, an advantage when the attendance of a hall swings widely.\u003c\/p\u003e\n\n\u003ch3\u003eThe packaged principle, at the scale of large volumes\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e brings together in a single outdoor cabinet the compressors, the coils, the fans and the control. Installed on the roof or on a pad, it connects to the supply and return ducts, cools in summer and heats by heat pump the rest of the year. In a room with a high ceiling, it leaves the indoor space completely free. The unit uses \u003cstrong\u003eR-410A\u003c\/strong\u003e, the previous-generation refrigerant: a proven technology, with two separate charges, one per circuit.\u003c\/p\u003e\n\u003cp\u003eOn the construction side, the unit is assembled in Norman, Oklahoma, goes through a fully automated run test on the assembly line and arrives configured and commissioned at the factory. Its embossed top stiffens the cabinet, its powder paint is rated at 750 hours of salt spray, and YORK tests and rates it for cooling up to an outdoor temperature of 125 °F (52 °C).\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eData\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e10 tons (120,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e115,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e114,000 BTU\/h, COP of 3.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e62,000 BTU\/h, COP of 2.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eEER of 11.0, IEER of 14.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e3,600 CFM (ft³\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e575 V, three-phase, 60 Hz (540 to 630 V applied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressors\u003c\/td\u003e\n\u003ctd\u003e2 scroll, independent circuits, 50% \/ 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (width x length x height)\u003c\/td\u003e\n\u003ctd\u003e61.7 x 87.2 x 48.6 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e1,060 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor sound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e86 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eThe XXE12A5C3AA1B111A3 configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBelt-drive indoor fan, high static pressure option.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e on the supply fan.\u003c\/li\u003e\n\u003cli\u003eFactory-installed dry bulb economizer.\u003c\/li\u003e\n\u003cli\u003eSmart Equipment control and factory-installed supply, return and outdoor air sensors.\u003c\/li\u003e\n\u003cli\u003eStandard coils: three-row condenser of 25.6 ft², four-row evaporator of 11.1 ft², thermostatic expansion valves (TXV).\u003c\/li\u003e\n\u003cli\u003eNo disconnect switch, no convenience receptacle and no factory electric heat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHeating a very large volume\u003c\/h3\u003e\n\u003cp\u003eIn heating mode, the heat pump delivers 114,000 BTU\/h at 47 °F and 62,000 BTU\/h at 17 °F. For the colder days, the YORK electrical tables list two electric heat kits in 575 V for this model, of 17 kW and 34 kW, installed in the field. We select the kit from the actual heat loss of the building and plan the matching disconnect switch.\u003c\/p\u003e\n\n\u003ch3\u003ePlanning the installation of a 1,060 lb unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifting:\u003c\/strong\u003e base rails around the full perimeter, with holes for the lifting shackles and for the forks of a forklift.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof curb:\u003c\/strong\u003e rigid large cabinet curbs of 14 in. (1RC0457) or 24 in. (1RC0459); the base rail also fits many existing curbs, which we confirm on site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 72 in. above, 48 in. at the front, 36 in. at the back since the economizer is installed, 18 in. on the right side and 12 in. on the left side.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSound:\u003c\/strong\u003e with a rating of 86 dBA, we position the unit with the neighbouring windows and buildings in mind.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e disconnect switch in the field and through-the-base connection kit (1TB0404) to avoid another hole in the roof.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity:\u003c\/strong\u003e burglar bars (1BD0410) and smoke detectors for the supply or return air available as accessories.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eQuick maintenance in spite of the size\u003c\/h3\u003e\n\u003cp\u003eThe condenser is cooled by a single 30 in. direct-drive fan, fastened to the grille for quick maintenance. The four 20 x 20 x 2 in. filters, shipped as MERV 4, are replaced without tools by MERV 8 or MERV 13 if needed. The LCD screen of the Smart Equipment board and its USB port give access to the fault codes, the history and the start-up reports, and a fault detection and diagnostics (FDD) module on the refrigerant side is available as an accessory.\u003c\/p\u003e\n\n\u003ch2\u003eTrust your very large volumes to AirGreen\u003c\/h2\u003e\n\u003cp\u003eA 10 ton unit is chosen from measurements, not from a remote estimate. During the \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, we survey the volume, the maximum occupancy, the duct system, the 575 V distribution and the access for the crane. Our teams install the unit, balance the 3,600 CFM, set up the economizer, the drive and the control, then take care of the planned maintenance.\u003c\/p\u003e\n\u003cp\u003eGyms, big-box stores and multipurpose halls in Montreal, Laval, Longueuil, on the North Shore and on the South Shore: our HVAC teams respond quickly and efficiently. Call us at 514 316-2973 or fill out the form on airgreen.ca to schedule your visit.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367219212580,"sku":"XXE12A5C3AA1B111A3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_6_A_10_TONNES_00_PRINCIPALE_de7a9651-05ee-4f07-b1f1-7ad635e94100.png?v=1790963102"},{"product_id":"thermopompe-monobloc-york-wp-de-7-5-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WP 7.5 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eThe 7.5 ton Sun Pro WP: the R-454B generation for commercial projects meant to last\u003c\/h2\u003e\n\u003cp\u003eWhether it is a new building or a rooftop unit that has reached the end of its service life, the owner of a mid-size business today has two generations of refrigerant to choose from. This 7.5 ton YORK Sun Pro WP \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e represents the \u003cstrong\u003eR-454B\u003c\/strong\u003e generation of the Sun Pro line: a rooftop unit fed in \u003cstrong\u003e208\/230 V three-phase\u003c\/strong\u003e, with two scroll compressors, an EER of 12.2, an IEER of 16.0 and a factory-installed refrigerant detector. AirGreen offers it, installs it and maintains it for businesses, offices and buildings in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eA commercial-grade packaged heat pump\u003c\/h3\u003e\n\u003cp\u003eA packaged heat pump gathers the compressors, the coils, the fans and the control in a single outdoor cabinet. Set on a roof curb, on a pad or on a steel structure, it connects directly to the supply and return ducts of the building. In summer it cools; the rest of the year it heats by reversing its cycle, and an electric heat kit can top up its capacity in deep cold. No equipment takes up the sales floor, the stockroom or the drop ceiling, and our technicians carry out the maintenance on the roof, without disturbing your occupants. Every Sun Pro unit leaves the factory charged with refrigerant, wired, piped and tested, which simplifies the work in the field.\u003c\/p\u003e\n\u003ch3\u003eWP090 or XP090: what the R-454B generation changes\u003c\/h3\u003e\n\u003cp\u003eAirGreen also offers the R-410A version in the same size, the Sun Pro XP090. Both units share a cabinet of the same dimensions and an identical weight, but their cooling ratings differ. Here is the comparison, taken from the YORK technical guides for each series:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eWP090 (R-454B)\u003c\/th\u003e\n\u003cth\u003eXP090 (R-410A)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e96,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e92,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER\u003c\/td\u003e\n\u003ctd\u003e12.2\u003c\/td\u003e\n\u003ctd\u003e11.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEER with IntelliSpeed\u003c\/td\u003e\n\u003ctd\u003e16.0\u003c\/td\u003e\n\u003ctd\u003e14.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e87,000 BTU\/h, COP of 3.5\u003c\/td\u003e\n\u003ctd\u003e87,000 BTU\/h, COP of 3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e51,000 BTU\/h, COP of 2.25\u003c\/td\u003e\n\u003ctd\u003e51,000 BTU\/h, COP of 2.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e3,000 CFM\u003c\/td\u003e\n\u003ctd\u003e3,000 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (width x length x height)\u003c\/td\u003e\n\u003ctd\u003e59 x 89 x 50.75 in.\u003c\/td\u003e\n\u003ctd\u003e59 x 89 x 50.75 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e1,090 lb\u003c\/td\u003e\n\u003ctd\u003e1,090 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIn heating, both units post the same ratings. In cooling, the WP delivers 4,000 BTU\/h more in net cooling, with an EER one point higher and an IEER 1.4 point higher. Since the footprint and the weight are the same, the choice comes down to the refrigerant and to the cooling performance, and not to the space available on the roof.\u003c\/p\u003e\n\u003ch3\u003eR-454B and the refrigerant detection system\u003c\/h3\u003e\n\u003cp\u003eR-454B is a class A2L refrigerant with a low global warming potential. Each of the two refrigerant circuits of the WP090 holds 12 lb 0 oz of it. According to its nomenclature, this model ships with the \u003cstrong\u003erefrigerant detection system\u003c\/strong\u003e (RDS): built-in sensors, tied to the unit control, automatically start a dilution sequence and set off an alarm when they detect refrigerant in the cabinet, at a concentration matching 25% of the lower flammability limit.\u003c\/p\u003e\n\u003ch3\u003eTechnical data for the WP090C00R2BABAA1A1\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal capacity: 7.5 tons (90,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 96,000 BTU\/h (99,000 BTU\/h gross capacity)\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 87,000 BTU\/h, COP of 3.5\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 51,000 BTU\/h, COP of 2.25\u003c\/li\u003e\n\u003cli\u003eEfficiency: EER of 12.2 and IEER of 16.0\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 3,000 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V, three-phase, 60 Hz (applied voltage from 187 to 252 V)\u003c\/li\u003e\n\u003cli\u003eCompressors: 2 scroll on independent circuits, stages of 50% and 100%\u003c\/li\u003e\n\u003cli\u003eOutdoor coil: 29.0 ft², two rows, split-face circuiting; indoor coil: 13.2 ft², four rows; thermostatic expansion valves (TXV)\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 59 x 89 x 50.75 in.\u003c\/li\u003e\n\u003cli\u003eWeight: 1,090 lb operating, 1,095 lb shipping\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270): 83 dB(A)\u003c\/li\u003e\n\u003cli\u003eFilters: four 24 x 20 x 2 in. disposable filters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe factory configuration, option by option\u003c\/h3\u003e\n\u003cp\u003eRead against the nomenclature of the YORK technical guide, model number WP090C00R2BABAA1A1 describes the following equipment:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e with a high static pressure belt drive (3 HP motor): the supply fan speed varies according to the number of compressors or heating stages that are running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEconomizer\u003c\/strong\u003e with a barometric relief damper, able to admit up to 100% outdoor air.\u003c\/li\u003e\n\u003cli\u003eRefrigerant detection system (RDS) and phase monitor, which stops the unit in the event of a lost phase or a reversed rotation.\u003c\/li\u003e\n\u003cli\u003eStand-alone Smart Equipment control, compatible with a thermostat or a zone sensor.\u003c\/li\u003e\n\u003cli\u003eStandard coils, without E-Coat coating, 2 in. disposable filters and standard cabinet.\u003c\/li\u003e\n\u003cli\u003eNo factory-installed electric heat, no disconnect switch and no convenience outlet: these are added in the field according to your needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTwo stages and a variable-speed fan\u003c\/h3\u003e\n\u003cp\u003eThe two compressors feed two independent refrigerant circuits, each with its own filter drier and its high and low pressure switches. On a mild day, a single compressor delivers half the capacity; the second starts when occupancy, lighting and sun add up. With the IntelliSpeed drive, the supply fan slows down on the first stage, then speeds up on the second, and the minimum position of the economizer can follow the drive frequency. It is this part-load operation that the IEER of 16.0 reflects, while the EER of 12.2 describes performance at full load. A compressor lead-lag function, selectable on the control board, also evens out their run hours.\u003c\/p\u003e\n\u003cp\u003eThe economizer on this model comes with AMCA 511 class 1A low-leakage dampers, which hold leakage to 3 CFM per square foot at 1 in. of static pressure, and every economizer goes through a 60,000 cycle test. Its modulating spring-return actuators open the outdoor air as the return closes, to cool without the compressor in the shoulder seasons.\u003c\/p\u003e\n\u003ch3\u003e208\/230 V supply and backup heat\u003c\/h3\u003e\n\u003cp\u003eAccording to the YORK electrical tables, this configuration with a high static pressure motor, without a powered convenience outlet, calls for a minimum circuit ampacity (MCA) of 43.8 A and a protection of no more than 50 A without electric heat. Four heat kits are planned for this size: E09, E18, E24 and E36. They deliver 6.8, 13.5, 18 and 25.5 kW at 208 V respectively, or 9, 18, 24 and 34 kW at 230 V; from the E18 up, they work in two stages, and all are designed for a single point of supply. With the E36 kit, the MCA reaches 132.3 A at 208 V and 146.1 A at 230 V. Since the heat pump delivers 87,000 BTU\/h at 47 °F and 51,000 BTU\/h at 17 °F, we choose the kit from the actual heat loss of the building and the capacity of your electrical entrance.\u003c\/p\u003e\n\u003ch3\u003eDesigned for maintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTool-free hinged panels for the control box, the compressors, the filters, the motor and the supply fan, screwed shut at the factory to block access by unauthorized people.\u003c\/li\u003e\n\u003cli\u003eService windows in both condenser walls to clean and inspect the coils.\u003c\/li\u003e\n\u003cli\u003eNon-corrosive condensate pan that slides out of the unit from the back, with a rigidly mounted 3\/4 in. female drain connection.\u003c\/li\u003e\n\u003cli\u003eFan performance measurement taps outside the cabinet, and a sliding motor and fan assembly.\u003c\/li\u003e\n\u003cli\u003eA second nameplate inside the control door, sheltered from the weather.\u003c\/li\u003e\n\u003cli\u003eSmart Equipment control with an LCD display, a USB port, a fault history and lockout of only the compressor concerned after three trips in two hours.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGetting the rooftop installation right\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof curb:\u003c\/strong\u003e YORK curbs of 8 in. (1RC0470) or 14 in. (1RC0471), with an insulated deck, shipped knocked down; a 10 in. transition curb (1RC0472) picks up the footprint of an older Sunline unit of 7.5 to 12.5 tons.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifting:\u003c\/strong\u003e full perimeter base rails with lifting holes for the crane and lift truck access on three sides.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 72 in. above, 36 in. at the front, at the back and on the left, 12 in. on the right; the unit can sit on a combustible floor or on a class A, B or C roof covering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDucts:\u003c\/strong\u003e conversion between a side connection and a bottom connection by moving the factory covers, with no panel cutting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating range:\u003c\/strong\u003e cooling down to 0 °F (-17.8 °C) outdoors for the comfort of the occupants thanks to the built-in low ambient control, and operation up to 125 °F (52 °C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAirGreen, from the estimate to the maintenance of your Sun Pro WP\u003c\/h2\u003e\n\u003cp\u003eIt all starts with a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e. We survey the area and the occupancy of your space, the condition of the ducts, the capacity of your three-phase entrance and the roof access for the crane, then we lay out clearly the two 7.5 ton options, R-454B and R-410A. Our crews then install the unit, set the IntelliSpeed drive, the economizer and the Smart Equipment control at commissioning, and handle the scheduled maintenance: filters, coils, belt, condensate pan and a read of the fault history.\u003c\/p\u003e\n\u003cp\u003eAn HVAC contractor based in Montreal, AirGreen serves Laval, Longueuil, the North Shore and the South Shore with quick, efficient service. Call 514 316-2973 or fill out the form on airgreen.ca to plan your visit: we answer quickly with a detailed quote.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367306539300,"sku":"WP090C00R2BABAA1A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_PRO_00_PRINCIPALE_4e9d37e7-5bd4-4da2-a786-821979c2c495.png?v=1790963083"},{"product_id":"thermopompe-monobloc-york-wqe-de-5-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WQE 5 Ton 575V | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eFor 575 V buildings moving to R-454B\u003c\/h2\u003e\n\u003cp\u003eWarehouse, shop, distribution centre or commercial building: when the electrical service is 575 V three-phase, the rooftop unit has to be built for that voltage. This 5-ton YORK Sun Core \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e (60,000 BTU\/h nominal), model WQE06A5C1AA5G111A1, answers that with R-454B and three factory-mounted options: a dry-bulb economizer, a belt-driven high static pressure blower and a refrigerant detection system (RDS). AirGreen sells and installs it in the commercial and industrial buildings of Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003cp\u003eIn the Sun Core line, the WQE is the standard-efficiency unit, below the high-efficiency WYE. Its \u003cstrong\u003eR-454B\u003c\/strong\u003e is an A2L refrigerant with a low global warming potential; the electric backup heat is installed on site.\u003c\/p\u003e\n\u003ch3\u003eWhat the model number tells you\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ecode 5 (voltage): 575 V, three-phase, 60 Hz;\u003c\/li\u003e\n\u003cli\u003ecode C (airflow): high static pressure, belt drive, an option reserved for three-phase models;\u003c\/li\u003e\n\u003cli\u003ecode 5 (sensors): factory-installed RDS;\u003c\/li\u003e\n\u003cli\u003ecode G (economizer): dry bulb, the \"enhanced static\" version;\u003c\/li\u003e\n\u003cli\u003ecode A (control): Smart Equipment, with a thermostat or a zone sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe BACnet MS\/TP, Modbus and N2 card (code B) is not included: if your building has a central management system, we confirm this point before ordering.\u003c\/p\u003e\n\u003ch3\u003eThe dry-bulb economizer, mounted and wired at the factory\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eeconomizer\u003c\/strong\u003e uses outdoor air to cool the rooms as soon as the outdoor temperature is below the set point of its module: that is the principle of dry-bulb control, useful when the lighting, the machines and the occupants warm the space in cool weather.\u003c\/p\u003e\n\u003cp\u003eThis downflow module, with barometric relief, arrives installed and wired; all that is left is to assemble the outdoor air hood supplied and fasten it to the unit. Its opposed galvanized steel blades, gear-driven, and its spring-return modulating actuators let it take in up to 100% outdoor air, even while the compressor is running. Its Class 1A low-leakage dampers, licensed to AMCA 511, reach a leakage rate of 3 CFM per square foot at 1 in. of static pressure.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control integrates it, accepts a CO₂ sensor and is ready for demand-controlled ventilation. A 575 V powered exhaust (kit 2PE04704258) can be added to it; it starts when the dampers pass an adjustable opening threshold.\u003c\/p\u003e\n\u003ch3\u003eA belt-drive blower for demanding duct systems\u003c\/h3\u003e\n\u003cp\u003eLong \u003cstrong\u003educts\u003c\/strong\u003e, filters with a higher MERV rating, an economizer: each element adds resistance to the air path. The high static pressure option on the WQE06 answers that with a 2.9 HP three-phase motor, an adjustable 1VL44 drive pulley and an 11 x 10 in. centrifugal blower.\u003c\/p\u003e\n\u003cp\u003eIts speed range runs from 1,167 to 1,593 rpm, against 792 to 1,208 rpm for the medium static pressure option. With a bottom connection, the YORK tables give 1,253 rpm for 1,500 CFM at an available external static pressure of 1.6 in. of water column, a speed out of reach for the medium option. YORK asks that the resistance of the economizer and, where applicable, of the heat kit be subtracted from it: so we measure the real pressure of your ducts before setting the pulley.\u003c\/p\u003e\n\u003ch3\u003eA single outdoor cabinet, watched over by the RDS\u003c\/h3\u003e\n\u003cp\u003eA packaged heat pump brings together the scroll compressor, copper and aluminum coils, blower, filters, control and economizer in one outdoor cabinet, set on the roof or at grade and tied into the ducts. Assembled at the factory, where every unit is configured and run-tested, the R-454B circuit stays outside the occupied rooms, inside that cabinet.\u003c\/p\u003e\n\u003cp\u003eR-454B belongs to Class A2L, that of the refrigerants with low toxicity and low flammability. The built-in sensors of the \u003cstrong\u003erefrigerant detection system\u003c\/strong\u003e are placed to detect a leak in the cabinet accurately and quickly. Tied to the control, the RDS automatically starts a refrigerant dilution sequence and raises an alarm as soon as the concentration reaches 25% of the lower flammability limit. No detection kit has to be added.\u003c\/p\u003e\n\u003ch3\u003eSpecifications of this configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated capacity: 5 tons (60,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eNet AHRI cooling: 57,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 53,000 BTU\/h, COP of 3.5\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 29,000 BTU\/h, COP of 2.15\u003c\/li\u003e\n\u003cli\u003eEfficiency: 14.0 SEER2, 6.7 HSPF2 and 11.8 EER2\u003c\/li\u003e\n\u003cli\u003eRated airflow: 1,550 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 575 V three-phase, 60 Hz (applied voltage from 540 to 630 V)\u003c\/li\u003e\n\u003cli\u003eDimensions (width, length, height): 48.9 x 74.1 x 40.6 in.\u003c\/li\u003e\n\u003cli\u003eWeight: 627 lb in operation, 640 lb shipping\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270): 77.8 dBA\u003c\/li\u003e\n\u003cli\u003eFilters: four of 16 x 16 x 2 in., MERV 4 as supplied\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eR-454B or R-410A: the comparison with the 575 V XQE06\u003c\/h3\u003e\n\u003cp\u003eWe also offer the XQE06 on R-410A in 575 V: the same 48.9 x 74.1 x 40.6 in. cabinet, the same 627 lb weight and the same 77.8 dBA sound rating.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFigure\u003c\/th\u003e\n\u003cth\u003eWQE06 (R-454B)\u003c\/th\u003e\n\u003cth\u003eXQE06 (R-410A)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet cooling\u003c\/td\u003e\n\u003ctd\u003e57,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e57,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e29,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e30,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2, HSPF2 and EER2\u003c\/td\u003e\n\u003ctd\u003e14.0, 6.7 and 11.8\u003c\/td\u003e\n\u003ctd\u003e13.4, 6.7 and 11.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe XQE06 delivers a little more capacity; the WQE06 gets the better SEER2, with an equal HSPF2 and an almost equal EER2. R-410A is a previous-generation refrigerant with proven technology; on the WQE06, the R-454B is watched by a factory-installed RDS. We compare the two with you.\u003c\/p\u003e\n\u003ch3\u003e575 V electrical work and backup heat\u003c\/h3\u003e\n\u003cp\u003eTwo \u003cstrong\u003eelectric heat\u003c\/strong\u003e kits are installed on site in 575 V: 13.8 kW (2EK04511458) and 23 kW (2EK04512358), hardware and connectors included. Here are the YORK values for this high static pressure blower configuration, with no powered convenience outlet (MCA: minimum circuit ampacity).\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eBackup heat\u003c\/th\u003e\n\u003cth\u003eMCA\u003c\/th\u003e\n\u003cth\u003eMaximum fuse or breaker\u003c\/th\u003e\n\u003cth\u003eMCA with powered exhaust\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e10.2 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003ctd\u003e10.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13.8 kW kit\u003c\/td\u003e\n\u003ctd\u003e26.8 A\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e27.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e23 kW kit\u003c\/td\u003e\n\u003ctd\u003e37.8 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003ctd\u003e38.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe maximum rating (dual-element time-delay fuse or HACR-type breaker) stays the same with the exhaust. With no factory disconnect, we install an external disconnect sized from the nameplate. The through-the-base electrical entry kit (1TB0403) avoids a new roof penetration.\u003c\/p\u003e\n\u003ch3\u003ePreparing the roof and the site\u003c\/h3\u003e\n\u003cp\u003eSince the factory economizer is downflow, the return air connects from below, ideally on a 14 or 24 in. YORK roof curb (1RC0456 or 1RC0458), with insulated decks, where the ducts are fastened before the unit is set in place.\u003c\/p\u003e\n\u003cp\u003eWith an economizer, YORK requires 36 in. of clearance at the back and prohibits any discharge of combustion products within 10 ft. of that back: so we locate chimneys and vents before settling the location, then plan the crane around the unit's 640 lb shipping weight.\u003c\/p\u003e\n\u003ch2\u003eAirGreen, from the 575 V check to commissioning\u003c\/h2\u003e\n\u003cp\u003eA 575 V project calls for coordinating the electrical work, the roofing and the ducts. Our teams handle it end to end: free on-site estimate, load calculation and sizing, installation, setting of the pulley and of the economizer, commissioning, then maintenance of the belt, the filters, the dampers and the RDS. As a Montreal \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor, we count on fast, efficient visits, planned to limit the interruption of your operations.\u003c\/p\u003e\n\u003cp\u003eFor a building in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, call 514 316-2973 or fill out the form on airgreen.ca: we will schedule your free on-site estimate quickly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367627829540,"sku":"WQE06A5C1AA5G111A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_08482e30-381e-44a9-b68a-1f5b4d32fd9a.png?v=1790963061"},{"product_id":"thermopompe-monobloc-york-xn-de-4-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XN 4 Ton 575V | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eFrom the plant's 575 V to office comfort, with no transformer and no new refrigerant\u003c\/h2\u003e\n\u003cp\u003eIf your industrial building is fed at \u003cstrong\u003e575 V three-phase\u003c\/strong\u003e and its rooftop units run on R-410A, the unit meant for the cafeteria, the offices or the control room should respect both of those choices rather than call for a transformer or a second refrigerant. The YORK Sunline XN048 \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e (4 tons, 48,000 BTU\/h nominal) is built for 575 V, delivered with a factory economizer and charged with R-410A. AirGreen, a Montreal HVAC contractor, installs it on industrial roofs in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eThe mechanical side stays outside, the occupied rooms stay clear\u003c\/h3\u003e\n\u003cp\u003eA packaged heat pump houses its scroll compressor, its coils, its fans, its filters and its control in a single outdoor cabinet, set on the roof or on a pad at grade; only the ducts enter the rooms it serves. For a control room or a cafeteria, maintenance happens up there, without disturbing the operators or the employees on break. Every unit leaves the factory charged, wired and tested.\u003c\/p\u003e\n\u003ch3\u003eNo transformer between the 575 V panel and the unit\u003c\/h3\u003e\n\u003cp\u003eThe XN048C00B5C1AAA1A2 unit leaves the factory ready for a 575 V, three-phase, 60 Hz supply: no step-down transformer is required. According to the YORK guide, the applied voltage can range from 540 to 630 V. Here are the circuit figures:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eBackup heat\u003c\/th\u003e\n\u003cth\u003eMCA\u003c\/th\u003e\n\u003cth\u003eMaximum protection\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNone, as delivered\u003c\/td\u003e\n\u003ctd\u003e9 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE10 kit (10.6 kW)\u003c\/td\u003e\n\u003ctd\u003e21.8 A\u003c\/td\u003e\n\u003ctd\u003e25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE15 kit (15.9 kW)\u003c\/td\u003e\n\u003ctd\u003e28.1 A\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE20 kit (21.2 kW)\u003c\/td\u003e\n\u003ctd\u003e34.5 A\u003c\/td\u003e\n\u003ctd\u003e35 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eMCA stands for the minimum circuit ampacity, protected by a dual-element time-delay fuse or by an HACR-type breaker. At 575 V, the indoor fan is always belt-driven, direct drive being reserved for the 208\/230 V models; its adjustable-pitch pulley allows the airflow to be matched to the duct system.\u003c\/p\u003e\n\u003ch3\u003eStaying with R-410A, with no break for the maintenance team\u003c\/h3\u003e\n\u003cp\u003eThe unit uses \u003cstrong\u003eR-410A\u003c\/strong\u003e, a previous-generation refrigerant whose technology is proven. If your other units run on it as well, your technicians keep a single refrigerant and their usual procedures. Placed on the suction line, a freeze-protection thermostat guards the unit against a loss of refrigerant and keeps the coil from icing up when the economizer sends in cool air while the compressor is running.\u003c\/p\u003e\n\u003ch3\u003eA single footprint for the ZE and XN series from 3 to 6 tons\u003c\/h3\u003e\n\u003cp\u003eYORK uses one cabinet for every ZE and XN size and configuration from 3 to 6 tons: the same \u003cstrong\u003eroof curb\u003c\/strong\u003e, 8 or 14 in. high, takes them all. We can therefore set the curb during the roofing work and settle the size of the unit and its heat option later, once the internal loads are worked out: the control room screens, the cafeteria occupancy, the kitchen appliances. An XN of 3, 4 or 5 tons will take the same space.\u003c\/p\u003e\n\u003ch3\u003eThe factory economizer, an asset for staff rooms\u003c\/h3\u003e\n\u003cp\u003eInstalled and wired at the factory, the \u003cstrong\u003eeconomizer\u003c\/strong\u003e brings in up to 100% fresh air as soon as the outdoor dry-bulb temperature drops below its set point. A control room full of screens or a cafeteria packed at noon then gets free cooling in spring and in fall; the control can lock out the compressor.\u003c\/p\u003e\n\u003cp\u003eWith no factory barometric relief damper, the air brought in has to find a way out: YORK offers that damper as an accessory, or a 575-3-60 powered exhaust for bottom-connected ducts. For the cafeteria, a CO2 sensor offered as an accessory takes over the economizer when the concentration rises above the preset limits.\u003c\/p\u003e\n\u003ch3\u003eControl room: operator comfort or equipment cooling\u003c\/h3\u003e\n\u003cp\u003eThe Smart Equipment control includes a low-ambient function: with no accessory, the unit can cool at an outdoor temperature as low as 0 °F (-17.8 °C) when it serves human comfort. Cooling electrical gear or servers in the middle of winter is closer to process cooling. YORK then recommends calling on its applications department, because stable operation below 30 °F (-1.1 °C) may require additional accessories. We check this point before confirming the selection.\u003c\/p\u003e\n\u003ch3\u003eAHRI performance, dimensions and weight\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated capacity:\u003c\/strong\u003e 48,000 BTU\/h, or 4 tons\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNet AHRI cooling:\u003c\/strong\u003e 47,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeat pump heating:\u003c\/strong\u003e 44,000 BTU\/h at 47 °F (8.3 °C), COP of 3.2; 24,900 BTU\/h at 17 °F (-8.3 °C), COP of 2.1\u003c\/li\u003e\n\u003cli\u003eEfficiency ratings, former standard: EER 11.8, SEER 14.0 and HSPF 8.0 (the XN series has no published SEER2 rating)\u003c\/li\u003e\n\u003cli\u003eRated airflow: 1,450 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 575 V three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eOverall size: 44.88 in. wide, 82.25 in. long and 32.63 in. high\u003c\/li\u003e\n\u003cli\u003eOperating weight: 616 lb (base unit)\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level to the AHRI 270 standard: 80 dB(A)\u003c\/li\u003e\n\u003cli\u003eFactory R-410A charge: 13 lb 10 oz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the XN048C00B5C1AAA1A2 number tells you\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSegment\u003c\/th\u003e\n\u003cth\u003eFactory configuration\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eC00\u003c\/td\u003e\n\u003ctd\u003eHeat pump with no factory electric heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003eBelt drive, standard static pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e575-3-60 power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003eFactory economizer, without barometric relief damper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eNo disconnect, no built-in convenience outlet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eWithout optional sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eSmart Equipment in the stand-alone version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eCoils without the E-Coat coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eWinter heat: a backup kit chosen to suit your rooms\u003c\/h3\u003e\n\u003cp\u003eAt 17 °F (-8.3 °C), the heat pump still delivers 24,900 BTU\/h. For colder days, an E10, E15 or E20 \u003cstrong\u003eelectric heat kit\u003c\/strong\u003e is installed on site. Its nickel-chrome elements are protected by auto-reset limit switches; for maintenance, the whole heating section slides out of the unit. With a kit, the airflow has to reach at least 1,200 CFM. We choose it from the heat losses of each room.\u003c\/p\u003e\n\u003ch3\u003eSmart Equipment, set to your schedules\u003c\/h3\u003e\n\u003cp\u003eDelivered in the stand-alone version, the \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control is driven by a conventional thermostat or by a zone sensor; the BACnet MS\/TP communication card is a factory option this model does not carry. One point to remember for fixed schedules: a factory-installed jumper between the R and OCC terminals of the control board forces occupied mode, whatever the thermostat or the energy management system calls for. We remove it at commissioning when those devices are meant to manage occupancy.\u003c\/p\u003e\n\u003ch3\u003eOur checklist before the lift\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e575 V circuit: wiring and protection from the YORK tables; disconnect on the bracket provided; supply through the 2 in. knockout, on the side or underneath.\u003c\/li\u003e\n\u003cli\u003eStructure and lift: 616 lb in operation for the base unit, plus 50 lb for the economizer; the crane slings pass through the corner holes in the rails.\u003c\/li\u003e\n\u003cli\u003eClearances with the economizer: 36 in. at the back and on the left, 24 in. at the front and on the right, 72 in. above.\u003c\/li\u003e\n\u003cli\u003eDucts: from below or from the back, even with the economizer; a low-resistance return, under 0.25 in. of water column, drops the airflow in full economizer mode.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eFrom the 575 V service through to maintenance, AirGreen runs your project\u003c\/h2\u003e\n\u003cp\u003eElectrician, roofer, crane operator, sometimes an engineer: we coordinate the trades, and our own teams carry out the installation.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree on-site estimate:\u003c\/strong\u003e visit of the rooms, survey of the electrical service and inspection of the roof.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSizing:\u003c\/strong\u003e load calculations, choice of the size, of the backup kit and of the air relief.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation and commissioning:\u003c\/strong\u003e lift, connections, setting of the pulley, of the economizer and of the occupancy modes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e filters (two 15 x 20 in., one 14 x 25 in.), belt, coils and economizer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe serve Montreal, Laval, Longueuil, the North Shore and the South Shore. For your free on-site estimate, call 514 316-2973 or write to us through the form on airgreen.ca: we call you back quickly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367630418212,"sku":"XN048C00B5C1AAA1A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUNLINE_WN_XN_00_PRINCIPALE_9f37b963-c6cb-457d-8acf-1637ec830034.png?v=1790963037"},{"product_id":"thermopompe-monobloc-york-xqe-de-3-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XQE 3 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eStore or office on 208\/230 V three-phase: 3 tons on R-410A in a 32.5 in. cabinet\u003c\/h2\u003e\n\u003cp\u003eIf your store or your office needs about 3 tons of cooling, if the electrical service is 208\/230 V three-phase and you prefer to stay on R-410A, the 3 ton YORK Sun Core XQE answers that profile. This \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e of 36,000 BTU\/h nominal, rated 13.4 SEER2, sits in the short 32.5 in. cabinet and comes with a belt-driven medium static pressure blower. At AirGreen, an \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor, we sell and install it in Montreal as well as in Laval and Longueuil, on the North Shore as on the South Shore.\u003c\/p\u003e\n\u003cp\u003eThe factory configuration of the XQE04A2B1AA1A111A2 model stays simple: Smart Equipment control, standard coils, no economizer, no disconnect switch and no built-in heat. In the field we add only what your space requires.\u003c\/p\u003e\n\u003ch3\u003eThe whole system outdoors, nothing on the sales floor\u003c\/h3\u003e\n\u003cp\u003eCompressor, coils, fans, filters and control share a single outdoor cabinet, installed on the roof or at ground level, then tied into the \u003cstrong\u003educt\u003c\/strong\u003e system. In summer, the unit cools; in winter, it heats in heat pump mode, with backup heat from an electric kit added in the field. Nothing encroaches on the sales floor or on the drop ceiling, and maintenance is done outside, without disturbing your customers.\u003c\/p\u003e\n\u003ch3\u003eCapacities, ratings and size at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI net cooling:\u003c\/strong\u003e 35,600 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating at 47 °F (8.3 °C):\u003c\/strong\u003e 34,200 BTU\/h, COP of 3.25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating at 17 °F (-8.3 °C):\u003c\/strong\u003e 18,500 BTU\/h, COP of 2.12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2 standard:\u003c\/strong\u003e 13.4 SEER2, 6.7 HSPF2 and 12.0 EER2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevious standard:\u003c\/strong\u003e 14.0 SEER and 8.1 HSPF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal airflow:\u003c\/strong\u003e 1,238 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 208\/230 V, three-phase, 60 Hz (allowable voltage from 187 to 252 V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth x depth x height:\u003c\/strong\u003e 48.9 x 74.1 x 32.5 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 529 lb operating, 542 lb shipping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor sound level (AHRI 270):\u003c\/strong\u003e 78.4 dBA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilters:\u003c\/strong\u003e two 16 x 25 x 2 in. disposable filters (MERV 4 as delivered)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAccessories specific to the 32.5 in. cabinet\u003c\/h3\u003e\n\u003cp\u003eOn the same footprint, the 4 and 5 ton XQE reach 40.6 in. in height; the 3 ton version stops at 32.5 in., the lowest cabinet of this size. Behind a low parapet, it stays more discreet. This short cabinet has its own accessories:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHail guard 1HG0419:\u003c\/strong\u003e a louvred panel set in front of the outdoor coil to protect its fins from hail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontal flow economizer 2EE04707024:\u003c\/strong\u003e for ducts connected from the side, since the unit can be converted in the field to a horizontal connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHinged panel 1HD0401 for filter access:\u003c\/strong\u003e the companion to that economizer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBelt-driven blower: the margin it gives your ducts\u003c\/h3\u003e\n\u003cp\u003eOn the 3 to 5 ton XQE, the base option is a direct-drive blower. The B in the eighth position of the model number stands instead for the \u003cstrong\u003emedium static pressure\u003c\/strong\u003e option: a double-inlet centrifugal wheel, belted to a 2.4 HP three-phase motor. Set by its variable-pitch drive pulley (1VL34), the blower speed runs from 792 to 1,208 rpm.\u003c\/p\u003e\n\u003cp\u003eAccording to the YORK tables, moving 1,200 CFM against 1.0 in. w.c. of external static pressure, in bottom connection, takes 1,191 rpm, which this option delivers. At the same pressure, the base direct-drive blower tops out at 872 CFM. In an office with long, elbowed ducts, that reserve helps hold the intended airflow; at start-up, we measure the pressure and set the pulley accordingly.\u003c\/p\u003e\n\u003ch3\u003eSmart Equipment in stand-alone mode and proven mechanics\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSmart Equipment\u003c\/strong\u003e is supplied here without a communication card, which suits a space with no building management system. A 24 V thermostat or a zone sensor is enough to drive it, and its three air sensors are already fitted at the factory. A CO2 sensor can also be connected to it: combined with an economizer, it adjusts the fresh air intake to occupancy. Its low ambient function lets the unit cool even when it is only 40 °F (4.4 °C) outside, an advantage in spring, when computers and lighting warm up the offices.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003escroll compressor\u003c\/strong\u003e is mounted on rubber grommets and internally protected against overheating and overcurrent. The coils pair internally grooved copper tubes with aluminum fins, and the blower compartment is insulated with 1\/2 in. fibreglass.\u003c\/p\u003e\n\u003ch3\u003eSame cabinet, two refrigerants: R-410A or R-454B\u003c\/h3\u003e\n\u003cp\u003eHere are the two versions of this 3 ton format:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eData\u003c\/th\u003e\n\u003cth\u003eXQE04 (R-410A)\u003c\/th\u003e\n\u003cth\u003eWQE04 (R-454B)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e35,600 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e35,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e18,500 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e19,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ HSPF2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e13.4 \/ 6.7 \/ 12.0\u003c\/td\u003e\n\u003ctd\u003e14.0 \/ 6.7 \/ 12.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions and weight\u003c\/td\u003e\n\u003ctd\u003e48.9 x 74.1 x 32.5 in., 529 lb\u003c\/td\u003e\n\u003ctd\u003eIdentical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower on the version offered\u003c\/td\u003e\n\u003ctd\u003eMedium static pressure\u003c\/td\u003e\n\u003ctd\u003eHigh static pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe WQE04 posts a slightly higher SEER2 and EER2 and heats a little more at 17 °F; it uses R-454B, an A2L refrigerant with a low global warming potential, and the version offered includes a refrigerant detection system (RDS). The XQE04 stays on R-410A, a proven technology from the previous generation, and its rating under the previous standard makes the comparison with an older unit easier. If your other equipment runs on R-410A, the XQE04 is the obvious choice; if the climate impact of the refrigerant comes first, we will propose the WQE04.\u003c\/p\u003e\n\u003ch3\u003eThe three-phase electrical service and the heat kits\u003c\/h3\u003e\n\u003cp\u003eFor this configuration with no electric backup, the YORK guide gives an MCA (\u003cstrong\u003eminimum circuit ampacity\u003c\/strong\u003e) of 20.2 A at 208 V and 20.5 A at 230 V; the maximum protection is 30 A (time-delay fuse or HACR breaker). Three heat kits are installed in the field:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2EK04510625: 6.5 kW at 230 V (4.9 kW at 208 V)\u003c\/li\u003e\n\u003cli\u003e2EK04511125: 10.5 kW at 230 V (7.9 kW at 208 V)\u003c\/li\u003e\n\u003cli\u003e2EK04511625: 16 kW at 230 V (12 kW at 208 V)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 16 kW kit brings the MCA to 68.6 A at 230 V and the maximum protection to 70 A: we therefore check your panel first. The unit arrives without a factory disconnect switch; we install one, sized from the nameplate, and a bottom power entry kit brings the supply in without piercing the membrane anywhere else.\u003c\/p\u003e\n\u003ch3\u003eBefore installation on a commercial roof\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSurvey the existing curb or plan a new 14 or 24 in. YORK curb, to which the ducts can be connected before the unit arrives.\u003c\/li\u003e\n\u003cli\u003eCheck the roof structure: the guide gives 127 to 137 lb at each corner of the unit.\u003c\/li\u003e\n\u003cli\u003eClear the space around the unit: 36 in. in front, 18 in. behind (36 in. with an economizer or a powered exhaust), 12 in. on the left, 18 in. on the right and 72 in. above for the air discharge.\u003c\/li\u003e\n\u003cli\u003ePlan the crane lift: the lifting shackles hook directly to the unit's base rails.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eAirGreen takes care of your 3 ton unit, from the survey to the maintenance\u003c\/h2\u003e\n\u003cp\u003eDuring the \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, we measure what drives the sizing: the actual load of the space, the static pressure of the ducts, the electrical service and the roof curb. We then recommend the XQE04 or the WQE04, with the right heat kit. We arrange the crane, connect the unit, balance the airflow and carry out the commissioning; our technicians come back through the seasons for the maintenance: filters, coils, belt and pulley.\u003c\/p\u003e\n\u003cp\u003eWe work in Montreal, Laval and Longueuil, as well as on the North Shore and the South Shore. To set up your free on-site estimate, a call to 514 316-2973 or a request through the form on airgreen.ca is all it takes: we will offer you a visit date without delay.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367633858852,"sku":"XQE04A2B1AA1A111A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_1948b118-e48d-4895-bc47-1e9c763479a1.png?v=1790963014"},{"product_id":"thermopompe-monobloc-york-xp-de-12-5-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XP 12.5 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eAt the top of the Sun Pro range: 12.5 tons for the largest commercial floor areas\u003c\/h2\u003e\n\u003cp\u003eA supermarket with doors opening non-stop, a reception hall that goes from empty to full in one evening, a gym where classes follow one after the other, a big-box store with endless aisles: these buildings call for a lot of capacity and a lot of air. The YORK Sun Pro XP150 \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e, fed by \u003cstrong\u003e208\/230 V three-phase\u003c\/strong\u003e, is the largest model in a series that runs from 6.5 to 12.5 tons, with a longer cabinet, four condenser fans and a rated airflow of 4,600 CFM. AirGreen takes care of the sizing, the installation and the maintenance in Montreal, Laval and Longueuil, as well as on the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eA single cabinet on the roof, a clear sales floor\u003c\/h3\u003e\n\u003cp\u003eA packaged heat pump houses the controls, the compressors, the coils and the fans in a single outdoor cabinet. The unit sits on a roof curb, a pad or a frame, then connects to the duct system, on the supply side and the return side; it cools in summer and heats the rest of the year. No mechanical room to plan for, nothing in the sales floor or in the drop ceiling, and maintenance carried out on the roof, without closing an aisle or moving a banquet. Every XP150 leaves the factory wired, tested and charged with \u003cstrong\u003eR-410A\u003c\/strong\u003e, the proven refrigerant of the previous generation.\u003c\/p\u003e\n\n\u003ch3\u003eKey characteristics of the XP150C00R2B1BAA1A3\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated capacity: 12.5 tons (150,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 141,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 138,000 BTU\/h, COP of 3.3\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 82,000 BTU\/h, COP of 2.15\u003c\/li\u003e\n\u003cli\u003eEfficiency: 10.6 EER, 14.5 IEER with IntelliSpeed\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V, three-phase, 60 Hz (187 to 252 V applied)\u003c\/li\u003e\n\u003cli\u003eCompressors: 2 scroll on independent circuits (stages of 50% and 100%)\u003c\/li\u003e\n\u003cli\u003eRated airflow: 4,600 CFM (ft³\/min), 5 HP motor\u003c\/li\u003e\n\u003cli\u003eCondenser: 4 fans of 24 in., 14,000 CFM in total\u003c\/li\u003e\n\u003cli\u003eDimensions (length x width x height): 119-7\/16 x 59 x 50-3\/4 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 1,403 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEER, IEER and two stages: reading the efficiency of a 12.5 ton unit\u003c\/h3\u003e\n\u003cp\u003eYou will find neither SEER nor HSPF on the data sheet of this model: from 6 tons up, a unit is compared in EER and in IEER. The \u003cstrong\u003e10.6 EER\u003c\/strong\u003e measures full-load performance; the \u003cstrong\u003e14.5 IEER\u003c\/strong\u003e, obtained with the IntelliSpeed drive, weighs performance at part load. That is where the two scroll compressors come in, delivering 50% and then 100% of the capacity: in a supermarket, the first one can be enough on a Tuesday morning, and the second starts on Saturday afternoon, when the lines at the checkouts get longer. The drive then sets the blower speed according to the number of active compressors.\u003c\/p\u003e\n\n\u003ch3\u003eA longer cabinet, four fans and a 5 HP motor\u003c\/h3\u003e\n\u003cp\u003eWhere the 6.5 to 10 ton models measure 89 in., the XP150 stretches to 119-7\/16 in. That length holds a condenser coil of 47.5 ft² (29.0 ft² on the other sizes) and \u003cstrong\u003efour 24 in. fans\u003c\/strong\u003e with direct drive instead of two, moving 14,000 CFM. Inside the cabinet, a 5 HP motor (184T frame), fitted with an adjustable-pitch sheave, belt-drives a 15 x 15 in. double-inlet centrifugal wheel; motor and wheel form a slide-out assembly. The tables in the guide cover external static pressures from 0.2 to 2.0 in. of water column, useful for long duct systems.\u003c\/p\u003e\n\n\u003ch3\u003eDecoding the model number\u003c\/h3\u003e\n\u003cp\u003eAccording to the YORK nomenclature, this number designates a 208\/230 V three-phase unit whose high static pressure drive is controlled by the \u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e, with an \u003cstrong\u003eeconomizer with barometric relief damper\u003c\/strong\u003e, a phase monitor, a Smart Equipment control in stand-alone mode, 2 in. disposable filters, standard coils and cabinet. Fitted with low-leakage AMCA 511 Class 1A dampers, the economizer admits up to 100% outdoor air and takes over from the compressors as soon as the outdoor air allows it. The unit is delivered with no service option (disconnect, convenience outlet) and with no electric heat.\u003c\/p\u003e\n\n\u003ch3\u003eElectric heat kits and ampacity: sizing the three-phase service\u003c\/h3\u003e\n\u003cp\u003eIn heat pump mode, the XP150 delivers 138,000 BTU\/h at 47 °F and 82,000 BTU\/h at 17 °F. When the cold gets sharper, YORK offers for this size \u003cstrong\u003eelectric heat\u003c\/strong\u003e kits in four sizes, namely 18, 24, 36 and 54 kW, two-stage and with single-point power. Without electric heat, the YORK tables drawn up for the high static pressure motor, in the version without a powered convenience outlet, give an \u003cstrong\u003eMCA (minimum circuit ampacity) of 78.4 A\u003c\/strong\u003e and a protection of 100 A at most. With the 54 kW kit, the MCA reaches 166.9 A at 208 V and 180.7 A at 230 V. The voltage counts too: this kit delivers 54 kW at 230 V, but 40.6 kW at 208 V.\u003c\/p\u003e\n\n\u003ch3\u003eSmart Equipment and phase monitor: a hard-working unit, closely watched\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e board receives its temperature sensors at the factory (supply air, return air, outdoor air). Its LCD screen displays the fault codes, whose history the USB port keeps. The board also protects the unit during a voltage drop, while the \u003cstrong\u003ephase monitor\u003c\/strong\u003e shuts it down if it detects a missing phase or a reversed rotation, two risks specific to three-phase power. Three safety trips in less than two hours lock out only the associated compressor. Finally, the built-in low-ambient control allows cooling down to 0 °F (-17.8 °C) outdoors, in a comfort application and with no additional component: useful when a hall full of guests warms the air well before spring.\u003c\/p\u003e\n\n\u003ch3\u003eCrane, roof curb and connections: preparing the job site\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStructure:\u003c\/strong\u003e 1,403 lb in operation for the base unit, plus 85 lb for the economizer according to the accessories table. The guide also gives the load per support point and the centre of gravity, useful to the structural engineer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifting:\u003c\/strong\u003e the rails that run around the base are drilled with lifting holes for the crane slings and accept the forks of a forklift on three sides; the lift is preferably planned outside business hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof curb:\u003c\/strong\u003e YORK offers curbs with insulated deck, 8 or 14 in. high and shipped knocked down, as well as a 10 in. transition adapter intended for Sunline curbs from 7.5 to 12.5 tons only. Since the XP150 cabinet is longer, we confirm the exact curb with the distributor before ordering; it has to rise at least 8 in. above the finished roof.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 72 in. clear above the four fans, 12 in. on the right side, 36 in. for the front, the back and the left side.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e a single electrical entry, on the side or from below, and a disconnect to plan for in the field; the ducts connect underneath or on the side, with no panel cutting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrom the visit to the start-up: AirGreen takes charge of your 12.5 ton unit\u003c\/h2\u003e\n\u003cp\u003eOur \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e covers the floor area and the height of the space, the occupancy peaks, the ducts, the three-phase service, the roof structure and the crane access; it makes it possible to confirm the size. We then organize the crane, install the unit and commission it: balancing the 4,600 CFM, setting the IntelliSpeed drive, the economizer and the Smart Equipment control. \u003cstrong\u003ePlanned maintenance\u003c\/strong\u003e then takes over: four 24 x 20 x 2 in. filters, belt, coils cleaned through the service windows, slide-out condensate pan and fault history.\u003c\/p\u003e\n\u003cp\u003eOur territory covers Montreal, Laval, Longueuil, the North Shore and the South Shore, with short response times and careful work. To book your visit, call 514 316-2973 or send your request through the form on airgreen.ca; a detailed quote follows quickly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367635398948,"sku":"XP150C00R2B1BAA1A3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_PRO_00_PRINCIPALE_9af310f9-ad90-4802-94be-0fb76bba0f71.png?v=1790962997"},{"product_id":"thermopompe-monobloc-york-xp-de-10-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XP 10 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eYour ventilation supplies the fresh air, this 10 ton rooftop unit supplies the comfort\u003c\/h2\u003e\n\u003cp\u003eIf your building already gets its fresh air from an \u003cstrong\u003eair exchanger\u003c\/strong\u003e or from a separate ventilation system, the rooftop unit does not have to take care of it: its job comes down to cooling and heating the return air. That is the mandate of the 10 ton YORK Sun Pro XP model, a \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e fed by \u003cstrong\u003e208\/230 V three-phase\u003c\/strong\u003e and delivered in its base configuration: no economizer, an IntelliSpeed drive, a high static pressure fan and two stages of cooling. An economizer or an outdoor air damper can be added later, as an accessory. AirGreen takes care of the supply, the installation and the maintenance in the greater Montreal area, including Laval and Longueuil as well as the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eTwo units, two clearly separate roles\u003c\/h3\u003e\n\u003cp\u003eIn a packaged unit, no mechanical component is installed inside the building: the two compressors, the two coils, the supply fan and the control board sit in a single outdoor cabinet, installed on the roof on a curb, at grade on a pad or on a frame, then connected to the ducts. In summer, the unit cools; in cold weather, it heats by reversing its cycle, with electric backup heat offered as an accessory. Where the ventilation is independent, the split is simple: the air exchanger renews the air, the packaged unit cools it or heats it. With no economizer, there is no outdoor air damper or actuator to inspect on the roof.\u003c\/p\u003e\n\u003ch3\u003eThe number XP120C00R2A1AAA1A2 in plain language\u003c\/h3\u003e\n\u003cp\u003eRead according to the YORK nomenclature:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSegment\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eXP120\u003c\/td\u003e\n\u003ctd\u003eSun Pro XP, packaged heat pump on R-410A, 10 tons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC00\u003c\/td\u003e\n\u003ctd\u003eNo factory electric heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003ctd\u003eIntelliSpeed (variable frequency drive) and high static pressure fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, three-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eNo economizer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eNo service option: the disconnect is installed in the field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eNo optional sensor (no phase monitor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eSmart Equipment board in stand-alone mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eStandard coils, without E-Coat coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eFour disposable 2 in. filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAirGreen also offers the same capacity in 575 V, with identical ratings, with an economizer and a phase monitor.\u003c\/p\u003e\n\u003ch3\u003eCapacities, ratings and footprint\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCooling: 111,000 BTU\/h of AHRI net cooling for a nominal 10 tons (120,000 BTU\/h); 11.0 EER, 14.5 IEER with IntelliSpeed\u003c\/li\u003e\n\u003cli\u003eHeat pump heating: 102,000 BTU\/h at 47 °F (8.3 °C), COP of 3.5; 59,000 BTU\/h at 17 °F (-8.3 °C), COP of 2.25\u003c\/li\u003e\n\u003cli\u003eFrom 6 tons up, the published ratings are EER and IEER, with no SEER or HSPF\u003c\/li\u003e\n\u003cli\u003eRated airflow: 3,300 CFM\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 187 to 252 V\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level: 83 dBA per AHRI 270\u003c\/li\u003e\n\u003cli\u003eFootprint: 89 in. long, 59 in. wide and 50.75 in. high, for 1,135 lb in operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eA fan for demanding duct systems, two stages for a variable load\u003c\/h3\u003e\n\u003cp\u003eThe supply fan, a belt-driven 15 x 15 in. double-inlet centrifugal wheel, receives the \u003cstrong\u003ehigh static pressure\u003c\/strong\u003e drive: YORK pairs it with a 3 HP motor and a variable-pitch drive sheave that allows the speed to be set between 880 and 1,110 rpm. That choice suits duct systems that impose a higher static pressure, such as long duct runs or runs loaded with accessories. External measurement ports make it possible to check the fan performance without opening a panel.\u003c\/p\u003e\n\u003cp\u003eEach scroll compressor has its own refrigeration circuit: only one runs when demand is moderate, both when it rises. The \u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e then varies the fan speed with the compressors or the heating stages that are active. The 11.0 EER corresponds to full-load operation; the 14.5 IEER weighs performance at several load levels.\u003c\/p\u003e\n\u003ch3\u003eAdding outdoor air later: the accessories YORK provides for\u003c\/h3\u003e\n\u003cp\u003eThe YORK guide provides for these field-installed accessories:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEconomizer\u003c\/strong\u003e 2EE04717625 (50 in. cabinet), for bottom supply or horizontal end return: hoods and barometric relief included, low-leakage dampers meeting AMCA 511 Class 1A, up to 100% outdoor air.\u003c\/li\u003e\n\u003cli\u003eHorizontal economizer for side return (2EE04706924), with barometric relief ordered separately and mounted in the ducts.\u003c\/li\u003e\n\u003cli\u003eMotorized damper (2MD04703824 bottom, 2MD04703924 horizontal), which opens to its preset position, between 0 and 100%, as soon as the indoor fan starts.\u003c\/li\u003e\n\u003cli\u003eManual bottom damper, from 0 to 35% (1FA0413) or from 0 to 100% (1FA0414), with hood and filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe economizer adds 85 lb in operation, and its static resistance is subtracted from the pressure available at the fan: we take it into account as soon as we set the drive. Once the economizer is installed, its minimum position can follow the drive frequency. Until then, a zone that calls for cooling in winter is served by the compressors, which the low-ambient control lets run down to 0 °F (-17.8 °C) outdoors, for the comfort of the occupants.\u003c\/p\u003e\n\u003ch3\u003e208\/230 V connection: currents and backup heat kits\u003c\/h3\u003e\n\u003cp\u003eYour electrician will take two values from the guide, the same at 208 V and at 230 V: a minimum circuit ampacity (\u003cstrong\u003eMCA\u003c\/strong\u003e) of 47.6 A and a protection of 60 A at most, by means of a dual-element time-delay fuse or an HACR breaker. They apply to the unit as delivered: high static pressure motor, no powered convenience outlet, no electric heat. Adding a power exhaust with the economizer brings the MCA to 53.1 A, the protection staying at 60 A.\u003c\/p\u003e\n\u003cp\u003eFour two-stage backup heat kits, designed for a single-point power connection, suit this size, and their capacity varies with the voltage available:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eKit\u003c\/th\u003e\n\u003cth\u003eAt 208 V\u003c\/th\u003e\n\u003cth\u003eAt 230 V\u003c\/th\u003e\n\u003cth\u003eMinimum airflow\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eE18\u003c\/td\u003e\n\u003ctd\u003e13.5 kW\u003c\/td\u003e\n\u003ctd\u003e18 kW\u003c\/td\u003e\n\u003ctd\u003e3,000 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE24\u003c\/td\u003e\n\u003ctd\u003e18 kW\u003c\/td\u003e\n\u003ctd\u003e24 kW\u003c\/td\u003e\n\u003ctd\u003e3,000 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE36\u003c\/td\u003e\n\u003ctd\u003e25.5 kW\u003c\/td\u003e\n\u003ctd\u003e34 kW\u003c\/td\u003e\n\u003ctd\u003e3,000 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE54\u003c\/td\u003e\n\u003ctd\u003e40.6 kW\u003c\/td\u003e\n\u003ctd\u003e54 kW\u003c\/td\u003e\n\u003ctd\u003e3,500 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWith the E54, the fan has to go beyond the nominal 3,300 CFM, and the choice of kit follows the heat loss of the building.\u003c\/p\u003e\n\u003ch3\u003eWhat your technician finds when opening the unit\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e board accepts a 24 V thermostat with two stages of heating and cooling, with or without an economizer, or a zone sensor. Its USB port gives access to the fault history and the start-up reports. The board only locks out a compressor on the third trip of the same safety within two hours.\u003c\/p\u003e\n\u003cp\u003eThe access panels open without tools, the four disposable filters measure 24 x 20 x 2 in., and the composite condensate pan slides out the back of the unit.\u003c\/p\u003e\n\u003ch3\u003eOn the roof: loads, curb and clearances\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLoads of 209 to 369 lb at the four support points, to be passed on to the structural engineer.\u003c\/li\u003e\n\u003cli\u003eYORK roof curbs available in 8 and 14 in. heights, with insulated deck; 10 in. transition adapter for the curb of an older Sunline (7.5 to 12.5 ton models).\u003c\/li\u003e\n\u003cli\u003eClear space of 12 in. on the right, 36 in. on the three other sides and 72 in. above.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrom the on-site survey to the maintenance: AirGreen runs your 10 ton project\u003c\/h2\u003e\n\u003cp\u003eEvery project opens with a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, which covers the ventilation as much as the cooling: existing fresh air supply, future needs, ducts and static pressure, the actual voltage of your three-phase service and crane access. If an economizer or a damper has to be planned, the quote says so.\u003c\/p\u003e\n\u003cp\u003eOur teams install the unit, adjust the sheave, set the IntelliSpeed drive and the Smart Equipment board, then come back at planned intervals for the filters, the belt, the coils, the condensate pan and the fault history. Our technicians travel quickly throughout our territory, from the North Shore to the South Shore by way of Laval, Montreal and Longueuil. To book your estimate, call 514 316-2973 or request it through the form on airgreen.ca.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367652831524,"sku":"XP120C00R2A1AAA1A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_PRO_00_PRINCIPALE_a52d8f13-20d2-443e-8f39-1fa5f37b3125.png?v=1790962979"},{"product_id":"thermopompe-monobloc-york-wp-de-10-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WP 10 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003e10 tons of cooling and heating under the supervision of your BAS\u003c\/h2\u003e\n\u003cp\u003eIn a building supervised by a building automation system (BAS), every rooftop unit has to fit into the existing communication network. The YORK Sun Pro WP, a 10 ton packaged heat pump on R-454B fed by 208\/230 V three-phase, leaves the factory with its \u003cstrong\u003eBACnet MS\/TP communication card\u003c\/strong\u003e, its high static pressure IntelliSpeed drive and its refrigerant detection system. It has no \u003cstrong\u003eeconomizer\u003c\/strong\u003e — the fresh air comes from separate ventilation. AirGreen handles the supply, the installation and the follow-up in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eOne cabinet on the roof, one unit on the network\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e brings the refrigeration circuit and the ventilation together under one outdoor shell: two scroll compressors on separate circuits, the coils, the supply fan and the controls. On the roof or at grade, it connects to the building's duct system, cools in two stages (50% and 100%) and switches to heating by reversing the cycle. For your operations team, it is a single piece of equipment, factory-tested, to tie into the BAS and to maintain.\u003c\/p\u003e\n\u003ch3\u003eA factory BACnet MS\/TP gateway, programmable to Modbus or N2\u003c\/h3\u003e\n\u003cp\u003eThe C control code designates the Smart Equipment option with communication: the full Smart Equipment control, paired with a \u003cstrong\u003eBACnet MS\/TP\u003c\/strong\u003e gateway programmable to Modbus or N2. The supply air, return air and outdoor air temperature sensors are factory-installed, and the board monitors the pressure switches of each circuit as well as the supply voltage. The LCD screen displays the fault codes; the USB port is used to pull the history and the start-up reports, and to update the software. The board also manages the minimum supply air setpoint (LLC) and compressor swapping; the control wiring has its own entries.\u003c\/p\u003e\n\u003ch3\u003eAHRI ratings and physical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAHRI net cooling: 116,000 BTU\/h, 11.2 EER, 15.2 IEER\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 104,000 BTU\/h, COP of 3.5\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 60,000 BTU\/h, COP of 2.25\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V, three-phase, 60 Hz (187 to 252 V range)\u003c\/li\u003e\n\u003cli\u003eRated airflow: 3,300 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003eR-454B charge: 12 lb 0 oz and 11 lb 4 oz depending on the circuit\u003c\/li\u003e\n\u003cli\u003eDimensions and weight: 59 x 89 x 50.75 in., 1,135 lb operating\u003c\/li\u003e\n\u003cli\u003eFiltration: 4 disposable 24 x 20 x 2 in. filters\u003c\/li\u003e\n\u003cli\u003eOutdoor sound rating (AHRI 270): 83 dB(A)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHigh static pressure IntelliSpeed: reserve for your ducts\u003c\/h3\u003e\n\u003cp\u003eThe R code pairs the \u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e with the high static pressure drive package: a 3 HP motor instead of the standard 2 HP, good for 3.45 bhp continuous, and a speed adjustable from 880 to 1,110 rpm. The YORK tables for the WP120 go up to 2.0 in. of water column of external static pressure, a useful margin for long duct runs. The drive then modulates the speed with the number of compressors or heating stages running, which is what the 15.2 IEER reflects, since it weighs performance at part load.\u003c\/p\u003e\n\u003ch3\u003eR-454B and built-in leak detection\u003c\/h3\u003e\n\u003cp\u003eAn A2L class refrigerant, \u003cstrong\u003eR-454B\u003c\/strong\u003e has a low global warming potential. The \u003cstrong\u003erefrigerant detection system\u003c\/strong\u003e (RDS) of the WP120 is factory-installed: its sensors, wired to the board, are placed to spot a leak in the cabinet quickly. As soon as the concentration reaches the equivalent of 25% of the lower flammability limit, the system raises the alarm and automatically starts diluting the refrigerant.\u003c\/p\u003e\n\u003ch3\u003eNo economizer, as a complement to your ventilation\u003c\/h3\u003e\n\u003cp\u003eThe A code of the outdoor air option means \"no economizer\": the fresh air stays with your air exchanger or your ventilation unit. If interior spaces call for cooling in winter, the low-ambient control provides comfort cooling down to 0 °F (-17.8 °C) outdoors; for a server room, you first have to check with the YORK applications department.\u003c\/p\u003e\n\u003cp\u003eShould outdoor air be brought in by the unit, the guide provides for the \"BAS Ready\" economizer (ready for the BAS) for the 50 in. cabinet (2EE04709825), the 208\/230 V power exhaust (2PE04704706) and the single (2EC0401) or dual (2EC0402) enthalpy controls. The minimum economizer opening can then be slaved to the drive frequency.\u003c\/p\u003e\n\u003ch3\u003eCompared with the R-410A XP120\u003c\/h3\u003e\n\u003cp\u003eWe also offer the XP120, the proven R-410A counterpart from the previous generation. The cabinet (59 x 89 x 50.75 in.), the weight (1,135 lb) and the rated airflow (3,300 CFM) are identical; here are the differences according to the YORK guides:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCriterion\u003c\/th\u003e\n\u003cth\u003eWP120 (R-454B)\u003c\/th\u003e\n\u003cth\u003eXP120 (R-410A)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e116,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e111,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER and IEER\u003c\/td\u003e\n\u003ctd\u003e11.2 and 15.2\u003c\/td\u003e\n\u003ctd\u003e11.0 and 14.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e104,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e102,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e60,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e59,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA and maximum protection at 208\/230 V\u003c\/td\u003e\n\u003ctd\u003e52.5 A and 60 A\u003c\/td\u003e\n\u003ctd\u003e47.6 A and 60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl in the configuration offered\u003c\/td\u003e\n\u003ctd\u003eBACnet MS\/TP, Modbus and N2 card\u003c\/td\u003e\n\u003ctd\u003eStand-alone Smart Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant detection\u003c\/td\u003e\n\u003ctd\u003eFactory RDS\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWith identical COPs (3.5 and 2.25), the WP120 takes the lead on cooling and arrives ready for the BAS; the XP120 suits a building run by thermostat or a fleet already on R-410A.\u003c\/p\u003e\n\u003ch3\u003eElectrical connection and backup heat\u003c\/h3\u003e\n\u003cp\u003eAs delivered, the unit calls for a circuit with a \u003cstrong\u003eminimum circuit ampacity\u003c\/strong\u003e (MCA) of 52.5 A, protected by a dual-element time-delay fuse or an HACR breaker of 60 A maximum, at 208 V as at 230 V; adding a power exhaust brings those values to 58 A and 70 A. The power feed enters at a single point, on the side or underneath, and the disconnect, not supplied from the factory, is installed in the field.\u003c\/p\u003e\n\u003cp\u003eThe 10 ton size accepts four electric heat kits, all two-stage and connected to the same power point as the unit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eE18 (2TP04531825): 13.5 kW at 208 V, 18 kW at 230 V\u003c\/li\u003e\n\u003cli\u003eE24 (2TP04532425): 18 kW at 208 V, 24 kW at 230 V\u003c\/li\u003e\n\u003cli\u003eE36 (2TP04533625): 25.5 kW at 208 V, 34 kW at 230 V\u003c\/li\u003e\n\u003cli\u003eE54 (2TP04525425): 40.6 kW at 208 V, 54 kW at 230 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe minimum airflow is 3,000 CFM, or 3,500 CFM with the E54. At 208 V, the MCA reaches 99.4 A with the E18 and 141 A with the E36, for example. The choice of kit follows your heat load and the spare capacity of your electrical service.\u003c\/p\u003e\n\u003ch3\u003eWhat to plan before the lift\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eYORK roof curbs with insulated deck, shipped knocked down: 1RC0470 (8 in.) or 1RC0471 (14 in.); the 1RC0472 adapter (10 in.) sits on the existing curb of a Sunline from 7.5 to 12.5 tons.\u003c\/li\u003e\n\u003cli\u003ePerimeter base rails drilled for the crane; on four supports, the load ranges from 209 to 369 lb depending on the corner.\u003c\/li\u003e\n\u003cli\u003eClearances: 36 in. in front, behind and on the left, 12 in. on the right, 72 in. above.\u003c\/li\u003e\n\u003cli\u003eSide connection: the installer moves the two factory covers to the bottom openings, without cutting a panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAirGreen coordinates your project with the integrator and the electrician\u003c\/h2\u003e\n\u003cp\u003eAirGreen's \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e runs from the roof to the supervision station: ducts and static pressure, heat load, three-phase service, existing curb, crane access and the protocol of your BAS. The quote then compares the WP120 and the XP120.\u003c\/p\u003e\n\u003cp\u003eAt installation, we coordinate the crane, the electrician and your integrator, adjust the pulley and the drive to the measured airflow, then commission the board on the BAS network. Our technicians then take care of the planned maintenance and, from Montreal, get quickly to Laval, Longueuil, the North Shore and the South Shore. To book your estimate visit, reach us at 514 316-2973 or write to us from airgreen.ca.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 6 years on the compressor, 6 years on parts and 6 years on labor, straight from the distributor.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56368011116836,"sku":"WP120C00R2AAACA1A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_PRO_00_PRINCIPALE_f831ce39-d1fa-49c8-9e12-1c6d30b29199.png?v=1790962954"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/collections\/Thermopompe_Monobloc_York_Montreal_Laval_Longueuil_Rive_Sud_et_Rive_Nord.png?v=1768464756","url":"https:\/\/airgreen.ca\/en\/collections\/thermopompe-monobloc-york-montreal-laval-longueuil-rive-sud-et-rive-nord.oembed?page=2","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}