{"title":"Thermopompe Monobloc YORK PH3 | Montréal, Laval, Longueuil, Rive Sud \u0026 Nord","description":null,"products":[{"product_id":"thermopompe-monobloc-york-ph3-de-2-tonnes-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York PH3 2 Ton | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eSmall spaces: a 2 ton packaged heat pump sized as closely as possible\u003c\/h2\u003e\n\u003cp\u003eA condo with a rooftop terrace, a small townhouse or a recent addition does not need an oversized unit. It needs a \u003cstrong\u003eproperly sized\u003c\/strong\u003e unit, one that cools without chilling the room all at once and then shutting off, and that heats efficiently through the shoulder seasons. The 2 ton YORK PH3 heat pump meets that need with a rated capacity of 24,000 BTU\/h and the narrowest cabinet in the whole PH3 series: 35.75 in. wide. At AirGreen, we install it on the roof as well as at ground level, in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\u003ch3\u003eThe whole system in a single outdoor cabinet\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e brings together in one outdoor cabinet the compressor, the outdoor coil, the indoor coil and the blower that pushes the air into your ducts. Indoors, all that is left is the thermostat and the duct system: no furnace and no fan coil to fit into a closet. In a condo where every square foot counts, that is often the deciding argument. The unit sits on a roof curb or on a pad, and only the electrical connections and the supply and return ducts are done on site. YORK ships every unit fully wired, charged with R-454B refrigerant and factory tested before shipping.\u003c\/p\u003e\n\u003ch3\u003eWhy a 2 ton rather than a bigger unit\u003c\/h3\u003e\n\u003cp\u003eThe instinct to \"go bigger, just in case\" works against comfort. The PH3 uses a \u003cstrong\u003escroll compressor\u003c\/strong\u003e with a single stage: when it starts, it runs at full capacity. If that capacity clearly exceeds what the home needs, the thermostat setpoint is reached within a few minutes, the unit shuts off, then starts again shortly after. These short cycles multiply compressor starts and, above all, leave the moisture in the air.\u003c\/p\u003e\n\u003cp\u003eIn summer, \u003cstrong\u003edehumidification\u003c\/strong\u003e takes place on the indoor coil: the warm, humid air cools there, the water vapour condenses and the water drains into the condensate pan, a watertight, corrosion-resistant pan that meets ASHRAE 62 for indoor air quality. That work takes continuous run time. A unit matched to the real load runs longer on each cycle, pulls out more moisture and delivers the cool, dry air you appreciate during a heat wave. The performance tables in the YORK guide in fact separate total capacity from sensible capacity: the gap between the two is the moisture removed from the air.\u003c\/p\u003e\n\u003cp\u003eThat is why we never pick a capacity by eye. The YORK technical guide follows the same logic: you first determine the building's load, then you install the unit of the right capacity in the smallest possible footprint. We run that calculation during the estimate, taking into account the windows, the insulation, the orientation and how the rooms are occupied. The indoor blower speeds, set at the factory for cooling and for heating, can also be adjusted on site to fine-tune the balance between airflow and comfort.\u003c\/p\u003e\n\u003ch3\u003eSpec sheet for the 2 ton PH3\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel number: PH3E24N00S21 (YORK LX series)\u003c\/li\u003e\n\u003cli\u003eRated capacity: 24,000 BTU\/h (2 ton)\u003c\/li\u003e\n\u003cli\u003eNet cooling (AHRI): 23,800 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 22,200 BTU\/h, with a COP of 3.8\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 13,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eEfficiency: 13.4 SEER2, 6.7 HSPF2 and 11.1 EER2\u003c\/li\u003e\n\u003cli\u003eRated airflow: 880 CFM (cubic feet per minute)\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V single-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B, an A2L refrigerant with a low global warming potential\u003c\/li\u003e\n\u003cli\u003eDimensions (width x depth x height): 35.75 x 51.25 x 44 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 340 lb\u003c\/li\u003e\n\u003cli\u003eSound level (AHRI 270): 70.3 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eA narrow cabinet for roof terraces and tight yards\u003c\/h3\u003e\n\u003cp\u003eAt 35.75 in. wide, the 2 ton model uses the smaller of the two footprints in the series, while the 3 to 5 ton models move up to 45.75 in. Its height of 44 in. and its 340 lb operating weight make it the easiest unit to place on a roof terrace or along a narrow back yard. The \u003cstrong\u003ebase rails\u003c\/strong\u003e that run around the whole unit have lifting holes for a crane and let forklift forks in from all four sides. Where height is limited, they come off by removing two screws at each corner.\u003c\/p\u003e\n\u003cp\u003eOn a wood terrace or a roof covered with a class A, B or C covering, the YORK guide allows installation directly on those combustible materials, provided the factory base rails are left in place. We always check the structure before setting the unit down on it.\u003c\/p\u003e\n\u003ch4\u003eClearances to allow around the unit\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e36 in. above, for the vertical discharge of the outdoor fan;\u003c\/li\u003e\n\u003cli\u003e36 in. on the right side and on the side opposite the ducts;\u003c\/li\u003e\n\u003cli\u003e24 in. on the left side and 6 in. on the duct panel side.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe \u003cstrong\u003evertical discharge\u003c\/strong\u003e works in your favour on a terrace: the outdoor fan blows the air upward, so the warm air and the running noise move away from the living space and the neighbours, and the potted plants around the unit do not dry out.\u003c\/p\u003e\n\u003ch3\u003eRugged components in a smaller format\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOutdoor coil with rifled copper tubes and enhanced aluminum fins, protected by a louvred stamped metal grille;\u003c\/li\u003e\n\u003cli\u003eall-aluminum indoor coil, three rows deep, fed by factory-mounted thermostatic expansion valves (TXV);\u003c\/li\u003e\n\u003cli\u003edirect-drive indoor blower with a 1\/2 HP ECM motor, mounted on a slide-out assembly that pulls out easily for cleaning;\u003c\/li\u003e\n\u003cli\u003eG90 galvanized steel cabinet finished with a powder paint tested for 1,000 hours in salt spray;\u003c\/li\u003e\n\u003cli\u003efactory-installed refrigerant detection system (RDS) and a demand defrost board with preloaded defrost curves;\u003c\/li\u003e\n\u003cli\u003ehigh-pressure switch, loss-of-charge switch and a compressor internally protected against high pressure and high temperature.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBackup heat matched to the home\u003c\/h3\u003e\n\u003cp\u003eFor the coldest days, the PH3 accepts a 6HK \u003cstrong\u003eelectric heat kit\u003c\/strong\u003e installed on site. For the 2 ton model, the YORK guide lists kits of 5, 8 and 10 kW, which deliver 4.4 kW, 7.1 kW and 8.8 kW respectively at 230 V. A single-point wiring kit lets one circuit feed both the unit and the kit. Here too, we choose the kit from the heat loss calculation, without oversizing.\u003c\/p\u003e\n\u003ch2\u003eYour condo or your addition in AirGreen's hands\u003c\/h2\u003e\n\u003cp\u003eAirGreen inc. is a Montreal HVAC contractor that sells and installs. A single contact handles your project, from the first visit through to commissioning, with the speed and efficiency an occupied site demands.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eFree on-site estimate:\u003c\/strong\u003e we measure the available space, check access to the roof or the yard and assess your ducts;\u003c\/li\u003e\n\u003cli\u003ea load calculation to confirm that 2 tons really matches your needs, or to point you to another size;\u003c\/li\u003e\n\u003cli\u003einstallation by our crews: roof curb or pad, lifting, connection to the ducts and to the electrical supply, thermostat setup;\u003c\/li\u003e\n\u003cli\u003eperiodic maintenance to keep the filters, the coils and the condensate drain in good shape.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOur territory covers Montreal, Laval, Longueuil, the North Shore and the South Shore. Call us at 514 316-2973 or write to us through the form on airgreen.ca: we will set a time with you for the free on-site estimate, then give you a detailed quote for a packaged heat pump cut to the measure of your small space.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367079850276,"sku":"PH3E24N00S21","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_PH3_00_PRINCIPALE_b8f5ea20-df9f-43fd-991f-19730daa06db.png?v=1790086524"},{"product_id":"thermopompe-monobloc-york-ph3-de-3-tonnes-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York PH3 3 Ton | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eReplacing an old packaged unit without redoing your ducts\u003c\/h2\u003e\n\u003cp\u003eIn many bungalows and single-storey houses, cooling and heating have relied for years on a packaged unit sitting on a pad along the wall or installed on the roof. When that unit reaches the end of its life, the simplest solution is often to replace it with a unit of the same type. The 3 ton YORK PH3 heat pump, with a nominal capacity of 36,000 BTU\/h, lends itself very well to a \u003cstrong\u003ereplacement\u003c\/strong\u003e of this kind: it works on the all-in-one principle you already know, connects to your existing ducts and adapts to the configuration in place. Our crews carry out these replacements throughout the region, from Montreal to Laval and Longueuil, out to the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eThe same all-in-one principle, with up-to-date components\u003c\/h3\u003e\n\u003cp\u003eIf you already have a packaged unit, you know the principle: the compressor, the two coils and the blower are housed in a single outdoor cabinet, and the house receives only conditioned air, through the supply and return ducts. Nothing changes on that side. What changes is what sits inside the cabinet: a new-generation R-454B refrigerant, a high-efficiency ECM motor for the \u003cstrong\u003eindoor blower\u003c\/strong\u003e, a factory-mounted refrigerant detection system (RDS) and a demand defrost board whose defrost curves are preloaded according to the unit's capacities. The PH3 is a \u003cstrong\u003eheat pump\u003c\/strong\u003e, which means the same circuit provides cooling in summer and heating through the cold season, thanks to its reversing valve.\u003c\/p\u003e\n\u003ch3\u003eThe data for the 3 ton single-phase PH3\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePH3E36N00S21, YORK LX series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e36,000 BTU\/h (3 tons)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet cooling (AHRI)\u003c\/td\u003e\n\u003ctd\u003e35,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating capacity at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e34,000 BTU\/h, COP of 3.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating capacity at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e21,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency ratings\u003c\/td\u003e\n\u003ctd\u003e13.4 SEER2, 6.7 HSPF2, 11.1 EER2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e1,200 CFM (cubic feet per minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply voltage\u003c\/td\u003e\n\u003ctd\u003e208\/230 V single-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (width x depth x height)\u003c\/td\u003e\n\u003ctd\u003e45.75 x 51.25 x 47 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e423 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e72.9 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-454B (A2L, low global warming potential)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eSide or bottom connection, with no cutting\u003c\/h3\u003e\n\u003cp\u003eThe trickiest point in a replacement is where the ducts come in. In some houses, the ducts come in from the side, through the foundation wall; in others, from underneath, through a roof curb. The PH3 takes both, thanks to its \u003cstrong\u003econvertible airflow\u003c\/strong\u003e design. It leaves the factory with the bottom openings closed off, ready for side supply and return. To move to a bottom configuration, the two bottom panels are removed and put back in the side openings. No panel to cut, no extra part to order.\u003c\/p\u003e\n\u003cp\u003eOn the side, the supply and return connections are the same size, which makes it possible to reach the ducts of a low crawl space without transition pieces. If your existing ducts are round, YORK offers preformed rectangular-to-round adapters: 12 or 14 in. for horizontal connections, 16 or 18 in. for vertical connections in the roof curb.\u003c\/p\u003e\n\u003ch3\u003eReusing the existing pad or roof curb\u003c\/h3\u003e\n\u003cp\u003eOn the ground, the unit rests on its perimeter \u003cstrong\u003ebase rails\u003c\/strong\u003e, which keep it above the pad to limit corrosion. A closure kit for the rail openings keeps small animals from nesting in them, and an anchoring kit certified for wind load holds the unit firmly to its pad. At 45.75 in. wide and 51.25 in. deep, its footprint is compact; we check on site whether the existing pad can be reused.\u003c\/p\u003e\n\u003cp\u003eOn the roof, you have two options. YORK offers NRCA-approved roof curbs 8 or 14 in. high, hinged at each corner and shipped with a sealing strip. If a curb is already there, transition kits make it possible to keep it by adapting the unit's footprint to YORK Affinity curbs or to Carrier, Trane and Goodman curbs. The vertical supply and return openings are designed to fit between standard joists spaced 24 in. o.c., without altering the structure.\u003c\/p\u003e\n\u003ch3\u003eA cabinet built to stay outside for a long time\u003c\/h3\u003e\n\u003cp\u003eOld packaged units often end up rusted at the corners and at the bottom of the panels. The PH3 is built from pretreated G90 galvanized steel, coated with a \u003cstrong\u003epowder paint\u003c\/strong\u003e tested 1,000 hours in salt spray, which bonds better to the steel and resists the spread of rust. The one-piece top cover, with seamless corners and drip edges, seals better against water, while the outdoor coil grille, in slotted stamped metal, protects the fins from small objects.\u003c\/p\u003e\n\u003ch3\u003eWhat we check before removing the old unit\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe electrical supply.\u003c\/strong\u003e Without backup heat, the 3 ton PH3 calls for a minimum circuit ampacity (MCA) of 27.3 A and a maximum overcurrent protection (MOP) of 40 A, through an HACR-type breaker or a time-delay fuse. A field-supplied electrical disconnect must also be installed, and the supply voltage must sit between 187 and 252 V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe ducts.\u003c\/strong\u003e We inspect the system and assess its resistance: YORK does not recommend applications above 0.8 in. of water column of external static pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe support.\u003c\/strong\u003e A cracked or settled pad, a roof curb in poor condition: we report every defect and correct it before the unit goes in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDrainage.\u003c\/strong\u003e The 3\/4 in. female NPT condensate connection, rigidly fixed, must reach a proper drain point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe thermostat.\u003c\/strong\u003e The PH3 works with a conventional 24 V thermostat, electronic or electromechanical.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eElectric backup heat\u003c\/h3\u003e\n\u003cp\u003eIf your old unit had electric heat strips, the PH3 takes a field-installed 6HK kit. Four sizes are available for the 3 ton: 5, 8, 10 and 15 kW. The largest runs in two stages and delivers 13.2 kW at 230 V. With the single-point wiring kit offered as an accessory, the unit and its heat strips share a single supply.\u003c\/p\u003e\n\u003ch2\u003eA turnkey replacement with AirGreen\u003c\/h2\u003e\n\u003cp\u003eA successful replacement is won in the preparation. During the \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, we take down the dimensions of the old unit, the position of the connections, the condition of the pad or the roof curb and the capacity of your electrical service. We then confirm by calculation that 3 tons suits your house. On installation day, our crews remove the old unit, convert the PH3 openings if needed, connect it to the ducts and to the power, then carry out the full start-up. We then stay available for seasonal maintenance.\u003c\/p\u003e\n\u003cp\u003eYou live in Montreal, Laval, Longueuil, on the North Shore or on the South Shore and your packaged unit is showing its age: call 514 316-2973 or use the form on airgreen.ca to book the visit. We work quickly and efficiently to limit the time your house goes without cooling or heating.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367080112420,"sku":"PH3E36N00S21","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_PH3_00_PRINCIPALE_6c446f06-8a7e-42fd-bfa0-2ef519b16ee2.png?v=1790086524"},{"product_id":"thermopompe-monobloc-york-ph3-de-3-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York PH3 3 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eA business supplied in three-phase, a cabinet of residential size\u003c\/h2\u003e\n\u003cp\u003eNeighbourhood shop, professional practice, salon or service space: many small businesses occupy buildings supplied with \u003cstrong\u003e208\/230 V three-phase\u003c\/strong\u003e power. For these spaces, the 3 ton YORK PH3 heat pump comes in a three-phase version. You get the cooling and the heating of a 36,000 BTU\/h unit, housed in the same compact cabinet as the residential single-phase version and connected directly to the electrical supply of your building. AirGreen designs and installs these systems for the business owners and the building owners of Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eA complete unit, installed outside your sales floor\u003c\/h3\u003e\n\u003cp\u003eIn a business, indoor space earns its keep: it is there to display, to welcome customers or to work in. The \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e frees up that space, since all the refrigeration components and the distribution blower sit in a single outdoor cabinet, usually on the roof. The cooled or heated air comes down into the space through the supply ducts and returns to the unit through the return. No mechanical equipment takes up the back room, and the technicians do the maintenance outdoors, without disturbing your business.\u003c\/p\u003e\n\u003ch3\u003eWhat three-phase power changes\u003c\/h3\u003e\n\u003cp\u003eThree-phase spreads the load over three conductors. The YORK electrical data show it clearly: with no heat kit, the three-phase model calls for a circuit with a minimum circuit ampacity (MCA) of 21.8 A, with a maximum overcurrent protection (MOP) of 30 A. The single-phase version of the same 3 ton unit requires 27.3 A and 40 A. The protection has to be provided by an HACR type breaker or a time-delay fuse, and a field-supplied disconnect is mandatory. The applied voltage has to stay between 187 and 252 V.\u003c\/p\u003e\n\u003cp\u003eThe backup heat follows the same logic. In three-phase, the \u003cstrong\u003e6HK\u003c\/strong\u003e kits offered for this model are 10 and 15 kW, that is 8.8 and 13.2 kW actual at 230 V, or 7.2 and 10.8 kW at 208 V. Single-point wiring kits (S1-2SPWK031 for 10 kW, S1-2SPWK033 for 15 kW) bring together the terminal block, the fuse holders and the wiring to feed the unit and its heating elements from a single source.\u003c\/p\u003e\n\u003ch3\u003eSizing for a commercial space\u003c\/h3\u003e\n\u003cp\u003eA business is not calculated like a house. Display lighting, computers, work equipment, a storefront window in full sun and customers coming and going all add heat throughout the day. Our \u003cstrong\u003eload calculation\u003c\/strong\u003e takes these gains into account to confirm that 3 tons is enough. If the result points to a larger need, the three-phase 4 and 5 ton versions of the PH3 take up the same floor footprint of 45.75 x 51.25 in.; only the height of the unit increases.\u003c\/p\u003e\n\u003ch3\u003eSpecifications of the three-phase 3 ton PH3\u003c\/h3\u003e\n\u003ch4\u003ePerformance rated to the AHRI methods\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eNet cooling: 35,400 BTU\/h (3 ton nominal model)\u003c\/li\u003e\n\u003cli\u003eIn heating at 47 °F (8.3 °C): 34,000 BTU\/h and a COP of 3.6\u003c\/li\u003e\n\u003cli\u003eIn heating at 17 °F (-8.3 °C): 21,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eRatings: 13.4 SEER2 in cooling, 6.7 HSPF2 in heating, 11.1 EER2\u003c\/li\u003e\n\u003cli\u003eIndoor blower airflow: 1,200 CFM nominal (ft³\/min)\u003c\/li\u003e\n\u003cli\u003eSound level to the AHRI 270 standard: 72.0 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eInstallation data\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eModel: PH3E36N00S31 (YORK LX series)\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B, a class A2L refrigerant whose global warming potential is low, with a factory-mounted refrigerant detection system (RDS)\u003c\/li\u003e\n\u003cli\u003eOverall size: 45.75 in. wide, 51.25 in. deep and 47 in. high\u003c\/li\u003e\n\u003cli\u003eWeight once in service: 423 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe coefficient of performance (COP) measures efficiency in heating: at 47 °F, the 3 ton PH3 delivers 3.6 units of heat for every unit of electricity it consumes. The YORK performance tables show that this efficiency is better in mild weather, which makes the heat pump a sound choice for the fall and the spring.\u003c\/p\u003e\n\u003ch3\u003eA discreet installation on the roof\u003c\/h3\u003e\n\u003cp\u003eAt 47 in. high, with its rounded corners and its one-piece top cover, the PH3 has a low profile and a clean look that fit easily on a commercial roof. Its outdoor fan discharges vertically: the exhaust air and the operating noise go up rather than toward the terrace next door or the windows on the floor above. The compressor is mounted on isolators, the rigid top panel dampens the noise and the formed base of the cabinet also contributes to the sound insulation.\u003c\/p\u003e\n\u003cp\u003eOn the roofing side, two heights of NRCA-approved YORK \u003cstrong\u003eroof curbs\u003c\/strong\u003e are offered, 8 in. and 14 in., with a gasket, along with a roof anchor kit certified for wind load. The bottom openings fit between standard joists at 24 in. o.c.: neither the framing nor the ducts have to be modified. The base rails include lifting holes for the crane, and the guide allows installation on a class A, B or C combustible roof covering when these factory rails stay in place.\u003c\/p\u003e\n\u003ch3\u003eFresh air for customers and staff\u003c\/h3\u003e\n\u003cp\u003eA space that welcomes the public needs fresh air. The PH3 can take a manual outdoor air damper, adjustable from 0 to 50%, or a motorized damper with the same range that closes in the event of a power failure; both include a hood and a screen. For more demanding needs, modulating integrated economizers are offered for vertical or horizontal configurations.\u003c\/p\u003e\n\u003ch4\u003eFilters supplied with the unit\u003c\/h4\u003e\n\u003cp\u003eAll the three-phase PH3 models ship with a filter rack kit and 1 in. filters, stored inside the unit when it leaves the factory. We install them at commissioning; they then stay accessible through a removable, sealed door, which makes replacing them during maintenance simple.\u003c\/p\u003e\n\u003ch3\u003eA simple thermostat for the whole team\u003c\/h3\u003e\n\u003cp\u003eOn the control side, a simple 24 V wall thermostat is enough, electronic or electromechanical. The unit accepts a single-stage model in heating and in cooling, with or without an economizer: your employees have only one setpoint to adjust. YORK also offers compatible thermostats in its accessory line. Inside the cabinet, an indicator light on the control board shows the status of the unit and helps the technician find the cause of a shutdown quickly, which shortens service calls.\u003c\/p\u003e\n\u003ch2\u003eAirGreen, your HVAC partner for commercial spaces\u003c\/h2\u003e\n\u003cp\u003eA commercial project takes coordination: roof access, opening hours, the requirements of the building owner. The first step is a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, during which we assess the thermal load of the space, the condition of the ducts, the three-phase supply available and the location on the roof. Our crews then take care of the complete installation, from the lift to the electrical hookup, and then the commissioning. We plan the work so as to limit the impact on your business hours, and we can take over the maintenance of the unit afterwards.\u003c\/p\u003e\n\u003cp\u003eWhether your business is in Montreal, Laval or Longueuil, or on the North Shore or the South Shore, call AirGreen at 514 316-2973 or request your free on-site estimate through the form on airgreen.ca. An advisor will call you back promptly to set up the visit to your space.\u003c\/p\u003e\n","brand":"York","offers":[{"title":"Default Title","offer_id":56367080145188,"sku":"PH3E36N00S31","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_PH3_00_PRINCIPALE_51e118de-7656-47f3-9150-a0ed98e8fd55.png?v=1790086524"},{"product_id":"thermopompe-monobloc-york-ph3-de-4-tonnes-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York PH3 4 Ton | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eFrom the ground floor to the upstairs: airflow that reaches everywhere\u003c\/h2\u003e\n\u003cp\u003eIn a two-storey house or a cottage, comfort is not measured at the thermostat alone. It is measured in the upstairs bedroom in July, in the living room in January and in every room in between. The 4 ton YORK PH3 heat pump, with a nominal capacity of 48,000 BTU\/h, suits this type of home well: its indoor blower, rated at 1,710 CFM, distributes the air through the existing duct system so that cooling and heating reach every level. AirGreen installs it on a pad or on a roof curb in the residential neighbourhoods of Montreal, Laval and Longueuil, as well as on the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eThe challenge of a two-storey home\u003c\/h3\u003e\n\u003cp\u003eWarm air rises, cool air falls. In summer, the upper floor warms up faster than the ground floor; in winter, it is often the basement or the lower rooms that stay cool. With a \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e, a single outdoor unit conditions the air and pushes it through the whole system: the compressor, the coils and the supply blower share the same cabinet, connected to the house by a supply duct and a return duct. The result on each floor therefore comes down to two things: enough \u003cstrong\u003eairflow\u003c\/strong\u003e and a well-balanced duct system.\u003c\/p\u003e\n\u003ch3\u003e1,710 CFM and an ECM blower that can be adjusted\u003c\/h3\u003e\n\u003cp\u003eThe indoor blower of the 4 ton PH3 is a double-inlet centrifugal wheel with forward-curved blades, driven directly by a high-efficiency 3\/4 HP \u003cstrong\u003eECM\u003c\/strong\u003e motor. The wheel is dynamically balanced to run smoothly over its entire operating range, and its sealed bearings are lubricated for life. Cooling and heating speeds are set at the factory, but we can adjust them on site to obtain the airflow that suits your ducts.\u003c\/p\u003e\n\u003cp\u003eAn existing duct system has its limits. YORK advises against any application where external static pressure exceeds 0.8 in. w.c. (water column). Before the installation, we therefore measure the resistance of your ducts and check for return air openings upstairs. Where needed, we add balancing dampers on the main branches to send a larger share of the air to the rooms that are short of it.\u003c\/p\u003e\n\u003ch4\u003eFilters sized for the airflow\u003c\/h4\u003e\n\u003cp\u003eA filter that is too small slows the air down before it even reaches the upper floor. On single-phase models, filters are supplied and installed on site: either in the return, in which case YORK requires them to be sized so the air velocity through a disposable filter does not exceed 300 ft\/min, or in the unit, with the filter rack kit offered as an accessory, which accepts 1 or 2 in. filters. We choose the solution that best protects your airflow.\u003c\/p\u003e\n\u003ch3\u003eThe numbers of the 4 ton PH3\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel PH3E48N00S21, YORK LX series, R-454B refrigerant\u003c\/li\u003e\n\u003cli\u003eNominal capacity of 48,000 BTU\/h and AHRI net cooling of 48,500 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating of 47,000 BTU\/h at 47 °F (8.3 °C), with a COP of 3.7\u003c\/li\u003e\n\u003cli\u003eHeating of 28,500 BTU\/h at 17 °F (-8.3 °C)\u003c\/li\u003e\n\u003cli\u003eSeasonal efficiency of 13.4 SEER2 in cooling and 6.7 HSPF2 in heating, EER2 of 11.1\u003c\/li\u003e\n\u003cli\u003eNominal blower airflow: 1,710 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003e208\/230 V single-phase power supply, 60 Hz\u003c\/li\u003e\n\u003cli\u003eCabinet of 45.75 x 51.25 x 50 in. (width x depth x height)\u003c\/li\u003e\n\u003cli\u003eOperating weight of 482 lb and AHRI 270 sound level of 71.6 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eTo exchange that much heat, the 4 ton model has a four-row all-aluminum indoor coil and a two-row outdoor coil made of rifled copper tubes and enhanced aluminum fins. Factory-installed thermostatic expansion valves meter the refrigerant, and a 26 in. outdoor fan with vertical discharge moves the air across the outdoor coil.\u003c\/p\u003e\n\u003ch3\u003eGround pad or roof curb: how to choose\u003c\/h3\u003e\n\u003cp\u003eThe PH3 connects from the side or from the bottom. It leaves the factory ready for side connections; for a bottom configuration, you simply move the two bottom panels over to the side openings, with no cutting. According to the YORK guide, the airflow difference between the two configurations is negligible: the choice is therefore made according to your house.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCriterion\u003c\/th\u003e\n\u003cth\u003eOn a ground pad\u003c\/th\u003e\n\u003cth\u003eOn a roof curb\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003eFrom the side, through the foundation wall, to a duct system in the basement or in the crawl space\u003c\/td\u003e\n\u003ctd\u003eFrom the bottom, through a flat roof section, to a duct system upstairs or in the attic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetting in place\u003c\/td\u003e\n\u003ctd\u003eHandling at ground level; the base rails are reachable by forklift from every side\u003c\/td\u003e\n\u003ctd\u003eCrane lift thanks to the holes provided in the base rails\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUseful accessories\u003c\/td\u003e\n\u003ctd\u003eAnchoring kit certified for wind resistance, kit that closes off the rail openings against small animals\u003c\/td\u003e\n\u003ctd\u003eNRCA-approved roof curb of 8 or 14 in., with sealing strip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClearances\u003c\/td\u003e\n\u003ctd\u003e36 in. on top, on the right and on the side opposite the ducts; 24 in. on the left\u003c\/td\u003e\n\u003ctd\u003eSame clearances, and openings designed to fit between standard joists spaced 24 in. on centre\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAt ground level, we place the unit away from bedroom windows and clear of the water dripping off the roof. The \u003cstrong\u003evertical discharge\u003c\/strong\u003e sends the warm air upward, away from your flower beds and shrubs, provided that no overhanging structure or branch blocks the air outlet.\u003c\/p\u003e\n\u003ch3\u003eBackup heat up to 20 kW\u003c\/h3\u003e\n\u003cp\u003eIn a two-storey house, electric backup heat deserves a precise calculation. For the 4 ton unit, the YORK guide lists 6HK kits of 5, 8, 10, 15 and 20 kW. The 20 kW kit runs in two stages and delivers 17.6 kW at 230 V, or 14.4 kW at 208 V. It requires 1 in. of clearance around the supply duct over the first three feet. Without a kit, the unit calls for a minimum circuit ampacity of 36.5 A and maximum overcurrent protection of 50 A; power for the unit and its kit can then be brought together at a single point with the S1-2SPWK004 wiring kit.\u003c\/p\u003e\n\u003ch2\u003eTrust our teams with the comfort of the whole family\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a Montreal HVAC contractor that sells and installs its own systems. For a two-storey house, our \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e visit covers the ducts as much as the unit: we examine the air path, the returns, the dampers and the possible location on a pad or on the roof. We calculate the load of each level, confirm that 4 tons meet your needs, then our teams carry out the installation, the balancing of the duct system and the start-up. Periodic maintenance follows, to keep filters, coils and the condensate drain in good condition.\u003c\/p\u003e\n\u003cp\u003eFrom Montreal to Laval, from Longueuil to the South Shore and out to the municipalities of the North Shore, we travel quickly to assess your home. Reach us at 514 316-2973 or through the form on airgreen.ca to book your free on-site estimate.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367080538404,"sku":"PH3E48N00S21","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_PH3_00_PRINCIPALE_194b9180-dece-4886-ab52-6faaa06e8258.png?v=1790086524"},{"product_id":"thermopompe-monobloc-york-ph3-de-4-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York PH3 4 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eCommon areas and small offices: a reliable heat pump, simple to maintain\u003c\/h2\u003e\n\u003cp\u003eEntrance hall, corridors, community room, ground floor offices in a mixed-use building: the common areas of a plex or a small building have to stay comfortable without becoming a headache for the owner or the manager. The 4 ton YORK PH3 heat pump in the \u003cstrong\u003e208\/230 V three-phase\u003c\/strong\u003e version suits this kind of assignment particularly well: 48,000 BTU\/h of nominal capacity, proven construction, easy service access and straightforward control. We install it for owners, condo boards and building managers across the greater region: Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eWhy a packaged unit in a building\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e concentrates the whole refrigeration system and the supply fan in a single cabinet, set on the roof or at ground level. The ducts carry the conditioned air into the common areas, then bring it back to the unit. No mechanical room to build, no indoor unit to fit into a corridor closet, and above all no need to enter the apartments for maintenance: the technician works outside, at the time that suits the building.\u003c\/p\u003e\n\u003ch3\u003eReliability starts at the factory\u003c\/h3\u003e\n\u003cp\u003eThe PH3 units are assembled in a plant whose quality management system is ISO 9001:2015 certified. Every unit is fully wired, charged with R-454B refrigerant and tested before shipping on computerized test stations. The refrigerant charge and the component numbers are verified by barcode scanning during assembly, and the run test data, such as the system pressures and the motor currents, is recorded. On request, this data can be retrieved from the serial number, an advantage for anyone who keeps a maintenance log. The unit is CSA certified to the UL 60335-2-40 and CAN\/CSA-C22.2 No 60335-2-40:22 standards.\u003c\/p\u003e\n\u003ch4\u003eThe standard protections\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHermetic scroll compressor whose internal protection combines a high pressure relief valve and a temperature sensor, which shut it down if operating conditions become inadequate;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ehigh pressure switch\u003c\/strong\u003e that locks the unit out under abnormal conditions, until it is reset;\u003c\/li\u003e\n\u003cli\u003eloss of refrigerant pressure switch, supplied with the unit, for a safe compressor shutdown;\u003c\/li\u003e\n\u003cli\u003etotally enclosed outdoor fan motor, internally protected against overloads;\u003c\/li\u003e\n\u003cli\u003efilter drier or strainer to catch the impurities in the refrigeration circuit, and refrigerant detection (RDS) built in at the factory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eService access designed for technicians\u003c\/h3\u003e\n\u003cp\u003eEvery major component has its own \u003cstrong\u003eaccess panel:\u003c\/strong\u003e compressor, indoor coil, fan, controls, electric heat kit and filters. The electrical box is not housed in the compressor compartment, and the controls are mounted so that their panel can be removed for diagnostics without disturbing the normal system pressures. The fan assembly and the indoor coil assembly slide out of the cabinet for cleaning. According to YORK, no special training is required to replace a component, and the number of unique parts has been reduced, which makes sourcing easier.\u003c\/p\u003e\n\u003ch3\u003eThe data for the 4 ton three-phase PH3\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eData\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003cth\u003eWhat it means\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePH3E48N00S31\u003c\/td\u003e\n\u003ctd\u003eYORK LX series, three-phase version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet cooling (AHRI)\u003c\/td\u003e\n\u003ctd\u003e48,500 BTU\/h\u003c\/td\u003e\n\u003ctd\u003eNet cooling capacity, fan heat deducted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e47,000 BTU\/h, COP of 3.7\u003c\/td\u003e\n\u003ctd\u003eHeating performance in mild weather\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e28,600 BTU\/h\u003c\/td\u003e\n\u003ctd\u003eCapacity kept in cold weather, before the electric backup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eSEER2 of 13.4, HSPF2 of 6.7 and EER2 of 11.1\u003c\/td\u003e\n\u003ctd\u003eRatings established under the requirements of the United States Department of Energy (DOE) and the AHRI methods\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e1,700 CFM (ft³\/min)\u003c\/td\u003e\n\u003ctd\u003eVolume of air delivered to the areas served\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e208\/230 V three-phase, 60 Hz\u003c\/td\u003e\n\u003ctd\u003eDirect connection to the building's three-phase service\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e45.75 in. x 51.25 in. x 50 in.\u003c\/td\u003e\n\u003ctd\u003eWidth, depth and height of the cabinet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e482 lb\u003c\/td\u003e\n\u003ctd\u003eUseful figure for checking the roof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e72.0 dBA\u003c\/td\u003e\n\u003ctd\u003eStandardized sound rating of the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eStraightforward control\u003c\/h3\u003e\n\u003cp\u003eNo complex programming to pass on to the caretaker: the PH3 is driven by a 24 V \u003cstrong\u003estandard thermostat\u003c\/strong\u003e, either an electronic model that does not draw its power from the control circuit, or an electromechanical model, single stage in heating as in cooling. The thermostat wires land on the screw terminals of the refrigerant detection system. Inside, the cooling controls rely on a contactor and relays, the connectors are the MATE-N-LOK type, and all the internal wiring is colour coded and numbered. A status and diagnostic indicator light on the board, along with a demand defrost control with preloaded curves, round out the package.\u003c\/p\u003e\n\u003ch3\u003ePower supply and backup heat in three-phase\u003c\/h3\u003e\n\u003cp\u003eWithout a heat kit, the 4 ton three-phase PH3 calls for a circuit with a minimum circuit ampacity of 24.5 A, protected at 35 A maximum by an HACR breaker or a time-delay fuse, plus a field-supplied disconnect switch. Three three-phase 6HK kits are planned for this model, of 10, 15 and 20 kW. The last one heats in two stages, delivers 17.6 kW at 230 V and includes its own breakers. Single point wiring kits (S1-2SPWK032, S1-2SPWK034 or S1-2SPWK035, depending on the kit chosen) allow a single power supply.\u003c\/p\u003e\n\u003ch3\u003eWhat we check at every maintenance visit\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eReplacement of the 1 in. filters, housed in the filter rack supplied with the three-phase models;\u003c\/li\u003e\n\u003cli\u003einspection and cleaning of the indoor coil and the blower wheel, pulled out of their housing if needed;\u003c\/li\u003e\n\u003cli\u003ecleaning of the outdoor coil and check of its protective grille;\u003c\/li\u003e\n\u003cli\u003echeck of the condensate pan and drain, whose 3\/4 in. NPT connection is rigidly fixed;\u003c\/li\u003e\n\u003cli\u003echeck of the electrical connections, the pressures and the operation in heating as in cooling.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe bearings on the indoor fan motor and the outdoor fan motor are lubricated for life: they call for no annual lubrication, which shortens the task list by that much.\u003c\/p\u003e\n\u003ch2\u003eA single point of contact for the installation and the maintenance of your buildings\u003c\/h2\u003e\n\u003cp\u003eAn HVAC contractor based in Montreal, AirGreen inc. sells, installs and maintains. For an owner or a manager, that means a single team from start to finish. It all begins with a \u003cstrong\u003efree on-site estimate:\u003c\/strong\u003e a review of the areas to be served, of the duct system, of the three-phase electrical service and of the location on the roof or at ground level. We calculate the load, prepare a clear quote, coordinate the lift and the access with you, then our crews install and commission the unit. After that, we can schedule the periodic maintenance of your equipment.\u003c\/p\u003e\n\u003cp\u003eOur crews travel quickly and efficiently everywhere on the island of Montreal, in Laval, in Longueuil as well as on the North Shore and the South Shore. For a plex, a small building or your offices, dial 514 316-2973 or use the online form at airgreen.ca.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367080571172,"sku":"PH3E48N00S31","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_PH3_00_PRINCIPALE_f92c6635-7b69-44a4-928c-b0827811f3de.png?v=1790086524"},{"product_id":"thermopompe-monobloc-york-ph3-de-5-tonnes-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York PH3 5 Ton | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eA large open-concept home: planning the capacity, the electrical service and the backup heat\u003c\/h2\u003e\n\u003cp\u003eKitchen, dining room and living room in one continuous space, open ceilings, large windows: an open-concept layout has plenty of charm, but it also means a large volume of air to cool and to heat. The YORK PH3 5 ton heat pump, with a rated capacity of 60,000 BTU\/h, is the largest single-phase model in the series. Choosing this unit well means planning three things at the same time: the home's \u003cstrong\u003eelectrical capacity\u003c\/strong\u003e, the \u003cstrong\u003ebackup heat\u003c\/strong\u003e and the distribution of 1,920 CFM of air. AirGreen guides the owners of large homes through each of these steps, in the Montreal, Laval and Longueuil area as well as on the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eA single outdoor unit for the whole living space\u003c\/h3\u003e\n\u003cp\u003eIn a \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e, the compressor, the coils and the blower that feeds the ducts are all in the same cabinet, outdoors, on a pad or on a roof curb. There is no furnace and no air handler to fit in the basement, which frees up space in a home where every room has a purpose. The cabinet, which measures 45.75 x 51.25 x 55 in. (width x depth x height), takes up the same floor area as the 3 and 4 ton models; only its height increases. It weighs 499 lb in operation and carries an AHRI 270 sound rating of 70.7 dBA.\u003c\/p\u003e\n\u003ch3\u003eThe performance of the 5 ton PH3\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eData\u003c\/th\u003e\n\u003cth\u003eIn cooling\u003c\/th\u003e\n\u003cth\u003eIn heating\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e57,500 BTU\/h (AHRI net cooling)\u003c\/td\u003e\n\u003ctd\u003e56,000 BTU\/h at 47 °F (8.3 °C); 33,700 BTU\/h at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e13.4 SEER2 and 11.1 EER2\u003c\/td\u003e\n\u003ctd\u003e6.7 HSPF2 and a COP of 3.4 at 47 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe model carries the number PH3E60N00S21 and its rated airflow is 1,920 CFM (ft³\/min). It runs on 208\/230 V single-phase, 60 Hz, and uses R-454B refrigerant, an A2L fluid with a low GWP (global warming potential), monitored by a factory-mounted refrigerant detection system.\u003c\/p\u003e\n\u003ch3\u003ePlanning the electrical capacity on single-phase\u003c\/h3\u003e\n\u003cp\u003eA home heated with electricity often already carries a heavy demand: range, water heater, baseboards, sometimes a charging station. Before adding a 5 ton heat pump and its backup heat, you have to know the numbers. According to the YORK guide, the 5 ton PH3 requires, without a heat kit, a circuit with a minimum circuit ampacity (MCA) of 43.5 A at 208 V or 39.3 A at 230 V, with a maximum overcurrent protection (MOP) of 70 A or 60 A. That protection takes the form of an HACR breaker or a time-delay fuse, completed by a field-installed disconnect.\u003c\/p\u003e\n\u003cp\u003eThe heat kit changes these values considerably. At 230 V, on a single power supply with a 20 kW kit, the minimum circuit ampacity climbs to 135.1 A and the maximum protection to 150 A. That is why we examine your panel and your electrical service before recommending a kit size, not after.\u003c\/p\u003e\n\u003ch3\u003eSizing the backup heat: the 6HK kits from 5 to 25 kW\u003c\/h3\u003e\n\u003cp\u003eThe heating capacity of a heat pump drops as the outdoor temperature falls: the 5 ton PH3 goes from 56,000 BTU\/h at 47 °F to 33,700 BTU\/h at 17 °F. The 6HK electric kit, installed inside the unit, fills the gap between that capacity and the heat loss of the home in cold weather. Here is what each kit actually delivers, depending on the supply voltage:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eKit\u003c\/th\u003e\n\u003cth\u003eStages\u003c\/th\u003e\n\u003cth\u003eAt 208 V\u003c\/th\u003e\n\u003cth\u003eAt 230 V\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 kW\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e3.6 kW (12,300 BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e4.4 kW (15,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8 kW\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e5.8 kW (19,700 BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e7.1 kW (24,100 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 kW\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e7.2 kW (24,600 BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e8.8 kW (30,100 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e15 kW\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e10.8 kW (36,900 BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e13.2 kW (45,100 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20 kW\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e14.4 kW (49,200 BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e17.6 kW (60,200 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25 kW\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e18 kW (61,500 BTU\/h)\u003c\/td\u003e\n\u003ctd\u003e22 kW (75,200 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThree points guide our choice. First, the actual voltage of your service: at 208 V, a kit gives noticeably less heat than at 230 V. Second, the wiring method: up to 20 kW, a single-point wiring kit (S1-2SPWK005 at 230 V) can group the power supply, while the 25 kW kit requires multiple circuits. Third, the installation: with the 20 and 25 kW kits, the supply duct has to keep a 1 in. clearance over its first three feet, and the blower has to respect the minimum speed YORK prescribes for each kit. The two-stage kits bring the backup heat on in steps rather than all at once.\u003c\/p\u003e\n\u003ch4\u003eThrough the winter, on the heat pump side\u003c\/h4\u003e\n\u003cp\u003eIn heating mode, the outdoor coil builds up frost. The PH3 handles it with a \u003cstrong\u003edemand defrost\u003c\/strong\u003e board in which YORK has preloaded defrost curves matched to the capacities of the unit, so that it defrosts when needed rather than at fixed intervals. As for the backup heat kits, the guide requires them to be certified to the UL 60335-2-40 standard; the 6HK models are offered with a built-in service disconnect, depending on the version chosen.\u003c\/p\u003e\n\u003ch3\u003eDistributing 1,920 CFM through an open-concept space\u003c\/h3\u003e\n\u003cp\u003eIn a large space without partitions, the air has to travel long distances before it reaches the reading corner or the picture window. The indoor blower of the 5 ton PH3 is driven directly by a 1 HP ECM motor, and its cooling and heating speeds, set at the factory, are adjusted on site. We place the supply grilles where the heat gains and losses are greatest, near the glazed surfaces, and we plan a return grille large enough not to restrict the airflow. YORK also advises against connecting the unit to a duct system whose resistance, measured as external static pressure, exceeds 0.8 in. w.c.\u003c\/p\u003e\n\u003cp\u003eOn the heat exchange side, the air passes through a four-row indoor coil made entirely of aluminum. The outdoor coil, the largest in the series with 26.4 ft² of face area, has two rows of internally grooved copper tubes with enhanced-surface aluminum fins.\u003c\/p\u003e\n\u003ch2\u003eFrom the electrical service to commissioning: the AirGreen approach\u003c\/h2\u003e\n\u003cp\u003eFor a large home, we take the project in order. During the \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, we measure the open space, note the windows and the insulation, inspect the electrical panel and assess the ducts already in place or still to be built. We then calculate the heat gains and losses to confirm that 5 tons is the right size, and we choose the 6HK kit that completes the heat pump without overloading your electrical service. Our crews carry out the installation, the hookup and the commissioning, then we handle the maintenance of the unit season after season.\u003c\/p\u003e\n\u003cp\u003eOur team covers the island of Montreal, Laval, Longueuil as well as the North Shore and the South Shore. To book your free on-site estimate, call 514 316-2973 or send your request through the form on airgreen.ca: a member of our team will get back to you quickly.\u003c\/p\u003e\n","brand":"York","offers":[{"title":"Default Title","offer_id":56367082799396,"sku":"PH3E60N00S21","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_PH3_00_PRINCIPALE_e80d9dbe-aa54-49e4-85ea-1dbbecc23fc5.png?v=1790086577"},{"product_id":"thermopompe-monobloc-york-ph3-de-5-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York PH3 5 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eRestaurants, clinics and showrooms: 5 tons of capacity in a compact cabinet\u003c\/h2\u003e\n\u003cp\u003eA dining room full on a Friday night, a clinic whose waiting room never empties, a showroom lit by spotlights behind a large storefront window: these light commercial spaces give off a lot of heat and must still stay comfortable from morning until closing. The 5 ton YORK PH3 heat pump in the \u003cstrong\u003e208\/230 V three-phase\u003c\/strong\u003e version delivers 60,000 BTU\/h of rated capacity in a cabinet whose footprint is no larger than 45.75 x 51.25 in. Installed on the roof, it leaves all of the indoor floor space to your customers, and its vertical discharge fan throws the air upward, away from your terrace. AirGreen carries out this type of installation for businesses located in Montreal, in Laval and in Longueuil, as well as on the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eA high heat load, calculated precisely\u003c\/h3\u003e\n\u003cp\u003eIn a restaurant or a clinic, the heat does not come from the sun alone. Every person present, every light fixture, every piece of equipment running adds its share, and the occupants also bring moisture. The \u003cstrong\u003eheat load\u003c\/strong\u003e of such a space is therefore high and variable. The performance tables in the YORK guide break down the total capacity and the sensible capacity of the PH3 according to indoor and outdoor temperatures: we use them to confirm that the unit will remove both the heat and the moisture from your space. If the calculation confirms it, 5 tons in a single unit simplifies the installation; if not, we propose another configuration.\u003c\/p\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e brings the compressor, the coils and the supply fan together in a single outdoor cabinet. The supply and return ducts connect it to the space, from below through the roof curb or from the side. In winter, the same machine heats by reversing its cycle, and an electric kit can supplement its capacity.\u003c\/p\u003e\n\u003ch4\u003eA lot of moisture, so a lot of condensate\u003c\/h4\u003e\n\u003cp\u003eThe more moisture the unit removes, the more water it produces. Under the indoor coil, a corrosion-resistant, fully sealed pan collects and drains all the condensate, leaving no standing water; its design meets ASHRAE 62 (ventilation and indoor air quality). The 3\/4 in. female NPT drain connection is rigidly mounted for a leak-free hookup; we then route the drain to a suitable discharge point on the roof.\u003c\/p\u003e\n\u003ch3\u003eThe 5 ton three-phase PH3 in numbers\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel number\u003c\/td\u003e\n\u003ctd\u003ePH3E60N00S31 (YORK LX series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling capacity\u003c\/td\u003e\n\u003ctd\u003e57,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e56,000 BTU\/h, for a COP of 3.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e34,200 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy efficiency\u003c\/td\u003e\n\u003ctd\u003eEER2 of 11.1, SEER2 of 13.4 and HSPF2 of 6.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnit airflow (rated)\u003c\/td\u003e\n\u003ctd\u003e1,825 CFM (ft³\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, three-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFootprint (width, depth, height)\u003c\/td\u003e\n\u003ctd\u003e45.75 in., 51.25 in. and 55 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e499 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSound rating (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e72.0 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-454B, classified A2L, with a factory-installed detection system (RDS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe direct-drive indoor fan uses a 1 HP ECM motor. The indoor coil has four rows, and the outdoor coil, with 26.4 ft² of face area, is the largest in the PH3 line.\u003c\/p\u003e\n\u003ch3\u003eThe rooftop installation, step by step\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe support.\u003c\/strong\u003e We validate the roof and choose the curb: a YORK roof curb, NRCA approved, 8 or 14 in. high, or a transition kit if an existing curb from another generation or another manufacturer has to be kept.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe lift.\u003c\/strong\u003e The unit weighs 504 lb as shipped. Its perimeter base rails are drilled with lifting holes meant for the crane and protect the cabinet during transport.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe anchoring.\u003c\/strong\u003e The unit is secured to its structure with the YORK roof mounting kit, certified to resist wind loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe connections.\u003c\/strong\u003e The vertical openings fit between standard joists 24 in. on centre. On the electrical side, without a heat kit, the circuit must provide a minimum circuit ampacity of 29.5 A, protected at no more than 45 A by an HACR breaker or a time-delay fuse, with a field-installed disconnect.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThe commissioning.\u003c\/strong\u003e We check the clearances, including 36 in. above the vertical discharge fan, then set the indoor fan speeds to suit your duct system.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eFresh air, economizer and CO2 control\u003c\/h3\u003e\n\u003cp\u003eA densely occupied space needs outdoor air. For the PH3, YORK offers \u003cstrong\u003emodulating integrated economizers\u003c\/strong\u003e, in a vertical or a horizontal version, which can run at the same time as mechanical cooling. Their independent-blade dampers show a leakage rate below 1%, and the assembly includes a hood with a bird screen and a temperature sensor. Single or dual enthalpy sensors improve outdoor air management, and CO2 detection kits, mounted in the duct, on the unit or on the wall, command the economizer when CO2 goes past the preset limits. For simpler needs, a manual or motorized damper provides 0 to 50% outdoor air. One technical detail we check: according to YORK, if the return duct resistance is below 0.25 in. w.c., the unit delivers less air when the economizer runs entirely on outdoor air.\u003c\/p\u003e\n\u003ch4\u003eCooling even in cool weather\u003c\/h4\u003e\n\u003cp\u003eA packed room can call for cooling in spring or in fall. In its standard configuration, the PH3 cools down to an outdoor temperature of 55 °F (12.8 °C). The low ambient kit offered by YORK extends cooling operation down to 0 °F (-17.8 °C).\u003c\/p\u003e\n\u003ch3\u003eThree-phase backup heat\u003c\/h3\u003e\n\u003cp\u003eFor this model, the three-phase 6HK kits run from 10 to 25 kW. The 25 kW kit heats in two stages and delivers 22 kW at 230 V, which is 75,200 BTU\/h, or 18 kW at 208 V. The 20 and 25 kW kits include their own breakers, and the S1-2SPWK035 single point wiring kit makes it possible to bring only one power feed to the unit. With the 25 kW kit on a single feed, the minimum circuit ampacity rises to 92.0 A at 208 V or 98.7 A at 230 V, for a maximum overcurrent protection of 110 A: your electrician needs to know this before preparing the service.\u003c\/p\u003e\n\u003ch2\u003eYour commercial project, managed by AirGreen\u003c\/h2\u003e\n\u003cp\u003eIn a business, every day of work counts. So we prepare everything ahead of time. The \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e lets us assess your space, its occupancy, its equipment, the duct system, the roof and the three-phase electrical service. We calculate the load, recommend the options worth having, such as the economizer or the backup kit, and plan the lift with you. Our crews install, connect and commission the unit quickly and efficiently, and then we can look after the regular maintenance of your equipment.\u003c\/p\u003e\n\u003cp\u003eRestaurant owners, clinics and retailers, whether you are in Montreal, in Laval, in Longueuil or on one of the two shores, North Shore or South Shore: call us at 514\u0026nbsp;316-2973 or send your request on airgreen.ca to get your free on-site estimate and a detailed proposal.\u003c\/p\u003e\n","brand":"York","offers":[{"title":"Default Title","offer_id":56367082832164,"sku":"PH3E60N00S31","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_PH3_00_PRINCIPALE_50b7975a-8505-47d4-9596-29e76890db5b.png?v=1790086577"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/collections\/THERMOPOMPE_MONOBLOC_YORK_PH3_00_PRINCIPALE_b8f5ea20-df9f-43fd-991f-19730daa06db.png?v=1790171262","url":"https:\/\/airgreen.ca\/en\/collections\/thermopompe-monobloc-york-ph3-montreal-laval-longueuil-rive-sud-nord.oembed","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}