{"title":"Thermopompe Monobloc YORK Sun Core WQE, WYE, XQE, XYE et XXE | Montréal, Laval, Rive Sud \u0026 Nord","description":null,"products":[{"product_id":"thermopompe-monobloc-york-wqe-de-3-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WQE 3 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eReplacing a 3 ton rooftop unit by making the most of the existing roof curb\u003c\/h2\u003e\n\u003cp\u003eWhen the 3 ton rooftop unit of a store, an office or a service space reaches the end of its service life, the most direct plan is to remove the old unit, check the roof curb and the ducts already in place, then set a new unit down in the same spot. The \u003cstrong\u003eYORK Sun Core\u003c\/strong\u003e cabinet was designed with the replacement market in mind: its full-perimeter base rail fits many existing roof curbs. At AirGreen, we plan this kind of replacement for businesses in Montreal, Laval, Longueuil, the North Shore and the South Shore, from the first site visit through to commissioning.\u003c\/p\u003e\n\u003cp\u003eThe WQE04A2C1AB5A111A1 model is a 208\/230 V three-phase 3 ton (36,000 BTU\/h nominal) \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e from the WQE series, the standard-efficiency version of the Sun Core line. It runs on R-454B refrigerant and takes, according to your needs, a field-installed electric heat kit.\u003c\/p\u003e\n\u003ch3\u003eA complete unit, set down on the roof curb\u003c\/h3\u003e\n\u003cp\u003eA packaged heat pump gathers the whole system in a single outdoor cabinet: compressor, outdoor coil, indoor coil, supply fan, filters and control. It is installed on the roof or at ground level and connects directly to the building's supply and return \u003cstrong\u003educts\u003c\/strong\u003e. On a replacement, nothing is added indoors: the work stays on the roof, then moves to the thermostat or zone sensor connection. In summer, the unit cools; in winter, the heat pump heats the space and the electric kit supplies backup heat when needed.\u003c\/p\u003e\n\u003ch3\u003eA full-perimeter base rail built for replacement\u003c\/h3\u003e\n\u003cp\u003eThe base rail runs around the entire perimeter of the cabinet. YORK builds it in a heavier gauge, with a shape worked out to avoid damage during transport and lifting; it has holes for the lifting shackles and for moving the unit with a forklift. Since no two roof curbs are ever exactly alike, we always measure yours before confirming compatibility.\u003c\/p\u003e\n\u003cp\u003eIf the existing curb does not work out, YORK offers two rigid roof curbs for its small cabinet size: the 14 in. 1RC0456 and the 24 in. 1RC0458, with an insulated deck and shipped unassembled. These same curbs serve the 3, 4 and 5 ton models (WQE04, WQE05, WQE06 and their WYE equivalents). That leaves you the option of moving up to a larger capacity later without rebuilding the curb.\u003c\/p\u003e\n\u003ch3\u003eModel specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal capacity: 3 tons (36,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 35,600 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 34,500 BTU\/h, COP of 3.5\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 19,500 BTU\/h, COP of 2.1\u003c\/li\u003e\n\u003cli\u003eEfficiency: 14.0 SEER2, 6.7 HSPF2 and 12.2 EER2\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 1,240 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V three-phase, 60 Hz (allowable applied voltage from 187 V to 252 V)\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 48.9 x 74.1 x 32.5 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 529 lb (542 lb shipping)\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level per AHRI 270: 78.4 dBA\u003c\/li\u003e\n\u003cli\u003eR-454B refrigerant, one scroll compressor on a single refrigeration circuit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eA short cabinet and a high static pressure blower\u003c\/h3\u003e\n\u003cp\u003eAt 32.5 in. tall, the 3 ton model uses the short cabinet of the small Sun Core size, while the 4 and 5 ton models reach 40.6 in. According to the YORK nomenclature, the letter C in the model number designates the high static pressure option: a belt-driven centrifugal blower, a 2.4 HP motor and an adjustable-pitch drive pulley. It is a sound choice when the existing duct system is long or includes several elbows, since the YORK tables cover up to 2.0 in. w.c. of available external static pressure. Before start-up, we measure the actual static pressure of your ducts and adjust the pulley to reach the target airflow.\u003c\/p\u003e\n\u003ch3\u003eWhat you gain over the old unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eR-454B refrigerant:\u003c\/strong\u003e an A2L refrigerant with a low global warming potential. According to the YORK nomenclature, this model includes the refrigerant detection system (RDS), which starts a dilution sequence and an alarm when it detects a leak equal to 25% of the lower flammability limit.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Equipment control:\u003c\/strong\u003e built-in LCD display, USB port, factory-installed temperature sensors, voltage monitoring and compressor lockout after three trips of the same safety within two hours.\u003c\/li\u003e\n\u003cli\u003eCommunication with a building management system: the model code provides for the BACnet MS\/TP, Modbus and N2 communication card.\u003c\/li\u003e\n\u003cli\u003eScroll compressor with internal protection, liquid line filter drier and high and low pressure switches.\u003c\/li\u003e\n\u003cli\u003eCoils with copper tubes and aluminum fins, embossed top for rigidity and powder paint rated 750 hours of salt spray.\u003c\/li\u003e\n\u003cli\u003e2 in. filters (two 16 x 25 x 2 in. filters, MERV 4 from the factory), reachable without tools through a dedicated panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical and backup heat: to confirm before the quote\u003c\/h3\u003e\n\u003cp\u003eThe existing circuit can be reused if its rating is adequate. Without backup heat, the YORK guide gives for this configuration a minimum circuit ampacity (MCA) of 22.5 A at 208 V and 22.8 A at 230 V, with a fuse or a breaker of 30 A maximum. Adding an electric heat kit changes these values. In 208\/230 V three-phase, the small size kits come in 6.5, 10.5 and 16 kW at 230 V, which gives 4.9, 7.9 and 12 kW when the actual supply is 208 V. We therefore measure the voltage at your electrical service before choosing the kit and the circuit rating; the unit's nameplate always has the last word.\u003c\/p\u003e\n\u003ch3\u003eHow a typical replacement unfolds\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVisit to your space: survey of the roof curb, the duct openings and the electrical service.\u003c\/li\u003e\n\u003cli\u003eLoad calculation to confirm that 3 tons still suit the current use of the space.\u003c\/li\u003e\n\u003cli\u003eOrder of the unit and, if needed, of a new roof curb, a heat kit, an economizer or a hail guard (kit 1HG0419, specific to the short cabinet).\u003c\/li\u003e\n\u003cli\u003eCrane lift: the unit weighs 542 lb as shipped and its rails are meant for lifting with shackles.\u003c\/li\u003e\n\u003cli\u003eRespect of the YORK clearances: 72 in. above, 36 in. at the front, 18 in. at the back (36 in. with an economizer or a powered exhaust), 18 in. on the right and 12 in. on the left.\u003c\/li\u003e\n\u003cli\u003eConnections, airflow adjustment, commissioning and a start-up report pulled from the control's USB port.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eEvery unit leaves the factory configured and run-tested, which simplifies commissioning on the roof. The control also allows cooling down to 40 °F (4 °C) outdoors with no additional component.\u003c\/p\u003e\n\u003ch2\u003eTrust AirGreen with your 3 ton replacement\u003c\/h2\u003e\n\u003cp\u003eWe sell and install YORK Sun Core packaged heat pumps, and our crews take charge of the whole project: free on-site estimate, sizing, lift coordination, duct and electrical connections, commissioning and maintenance. As an \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor based in Montreal, we also handle coordination with your building manager or your general contractor.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA single crew in charge, from the site visit to the first start-up\u003c\/li\u003e\n\u003cli\u003eWork planned around your business hours and carried out quickly\u003c\/li\u003e\n\u003cli\u003eRegular maintenance: filter changes, coil cleaning and belt inspection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhether your business is in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, we hand you a clear quote after our visit. To book your free on-site estimate, call us at 514 316-2973 or fill out the form on airgreen.ca: we get back to you quickly to set the date of the visit.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367201354020,"sku":"WQE04A2C1AB5A111A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_5a3515be-5bc4-4bfd-ab0f-17ece8154ebb.png?v=1790086673"},{"product_id":"thermopompe-monobloc-york-wqe-de-4-tonnes-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WQE 4 Ton | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eFour tons of comfort for your business, without three-phase service\u003c\/h2\u003e\n\u003cp\u003eA hair salon, a small grocery, a professional office or a ground-floor space in a mixed-use building: plenty of businesses have only a single-phase electrical service. Having three-phase service brought in for a single rooftop unit can call for major electrical work. The WQE05A1B1AB5A111A1 model avoids that detour: this 4 ton YORK Sun Core \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e (48,000 BTU\/h nominal) runs on 208\/230 V single-phase, 60 Hz. AirGreen sells, installs and maintains it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\u003cp\u003eIn the Sun Core lineup, single-phase power is reserved for the 3 to 5 ton models. The WQE series is the standard-efficiency version, with R-454B refrigerant, without factory-installed heat: an electric kit is added in the field according to your needs.\u003c\/p\u003e\n\u003ch3\u003eThe packaged unit, seen from the electrical side\u003c\/h3\u003e\n\u003cp\u003eA packaged heat pump brings the entire system together in a single outdoor cabinet, set on the roof or at ground level and connected to the supply and return ducts of the space. Compressor, coils, indoor blower, filters, control and, where applicable, heating elements share the same cabinet. For your electrician, that means a single main feed to plan for, plus the low-voltage thermostat wiring. There is no separate indoor unit to power and no refrigerant piping to run through the building.\u003c\/p\u003e\n\u003ch3\u003eModel specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePower supply: 208\/230 V single-phase, 60 Hz; allowable applied voltage from 187 V to 252 V\u003c\/li\u003e\n\u003cli\u003eCapacity: 4 tons, that is 48,000 BTU\/h nominal\u003c\/li\u003e\n\u003cli\u003eNet cooling per AHRI: 48,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 45,600 BTU\/h with a COP of 3.5\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 24,600 BTU\/h with a COP of 2.15\u003c\/li\u003e\n\u003cli\u003eEfficiency ratings: 14.0 SEER2, 6.7 HSPF2 and 12.2 EER2\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 1,550 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003eFootprint: 48.9 in. wide, 74.1 in. long and 40.6 in. high (48.9 x 74.1 x 40.6 in.)\u003c\/li\u003e\n\u003cli\u003eOperating weight: 628 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound rating per AHRI 270: 78.4 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese ratings are identical to those of the 4 ton three-phase version: going single-phase costs you neither capacity nor efficiency.\u003c\/p\u003e\n\u003ch3\u003eReference electrical data\u003c\/h3\u003e\n\u003cp\u003eThe YORK technical guide publishes the following values for this configuration (medium static pressure blower, without a powered convenience outlet or a powered exhaust). The scroll compressor has a rated load amperage (RLA) of 19.4 A and a locked rotor amperage (LRA) of 102 A.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eConfiguration\u003c\/th\u003e\n\u003cth\u003e208 V single-phase\u003c\/th\u003e\n\u003cth\u003e230 V single-phase\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithout backup heat: minimum circuit ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e33.9 A\u003c\/td\u003e\n\u003ctd\u003e33.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithout backup heat: maximum fuse or breaker size\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003ctd\u003e50 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit 2EK04511125: heat delivered\u003c\/td\u003e\n\u003ctd\u003e7.9 kW\u003c\/td\u003e\n\u003ctd\u003e10.5 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit 2EK04511125: minimum circuit ampacity (MCA)\u003c\/td\u003e\n\u003ctd\u003e81.4 A\u003c\/td\u003e\n\u003ctd\u003e88.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit 2EK04511125: maximum fuse or breaker size\u003c\/td\u003e\n\u003ctd\u003e90 A\u003c\/td\u003e\n\u003ctd\u003e90 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThese figures are used for planning; the nameplate of the unit delivered remains the reference for the final circuit sizing.\u003c\/p\u003e\n\u003ch3\u003eBackup heat: 208 V or 230 V, the difference counts\u003c\/h3\u003e\n\u003cp\u003eThe YORK 2EK04511125 kit is offered for the small cabinet in 208\/230 V, single-phase or three-phase. It is rated 10.5 kW at 230 V, but delivers only 7.9 kW when the actual voltage is 208 V. We therefore measure the available voltage before confirming your backup heat requirement. The factory non-fused disconnect comes in 60 A and in 100 A; YORK points out that it may be insufficient with certain heat kits. Above 100 A, it has to be removed and an external disconnect of the appropriate size installed.\u003c\/p\u003e\n\u003ch3\u003eA blower and a control designed for this power supply\u003c\/h3\u003e\n\u003cp\u003eThe model number carries a B in the eighth position, which corresponds, in YORK's nomenclature, to the medium static pressure blower. On this single-phase version, the belt-driven centrifugal blower gets a 1.5 HP motor fitted with an adjustable-pitch drive sheave. The high static pressure option is reserved for three-phase models; for demanding ducts, we therefore check the static pressure before confirming this choice.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control continuously monitors the voltage supplied to the unit and protects it in the event of a voltage drop or any other electrical deviation. It adds an anti-short-cycle delay, programmable minimum run times and independent fan delays in heating and in cooling. The built-in LCD screen shows the unit status, the supply, return and outdoor air temperatures as well as the fault codes. With a simple USB key, the built-in port makes it possible to retrieve current and previous faults and to update the software. The model code also provides for the BACnet MS\/TP, Modbus and N2 communication card as well as the refrigerant detection system (RDS), which monitors leaks of R-454B, an A2L refrigerant with a low global warming potential.\u003c\/p\u003e\n\u003ch3\u003eConstruction and compatible accessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle scroll compressor, a single circuit, thermostatic expansion valve (TXV), filter-drier and high and low pressure switches\u003c\/li\u003e\n\u003cli\u003eCoils with copper tubes and aluminum fins; direct-drive outdoor fan, dynamically balanced\u003c\/li\u003e\n\u003cli\u003eFour 16 x 16 x 2 in. filters, MERV 4 as supplied, replaceable with MERV 8 or MERV 13 filters thanks to the tool-less access panel\u003c\/li\u003e\n\u003cli\u003eVertical or horizontal flow economizers offered for all voltages, and powered exhausts in a 208\/230 V single-phase version\u003c\/li\u003e\n\u003cli\u003eLouvered hail guard (kit 1HG0420 for the tall cabinet)\u003c\/li\u003e\n\u003cli\u003e120 V convenience outlet with ground fault circuit interrupter, as a factory option\u003c\/li\u003e\n\u003cli\u003eFull perimeter base compatible with many existing roof curbs, or YORK curbs of 14 in. and 24 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat we check before the installation\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eThe capacity of the electrical panel and of the existing single-phase service, with or without backup heat.\u003c\/li\u003e\n\u003cli\u003eThe actual voltage (208 V or 230 V), which determines the heat delivered by the electric kit.\u003c\/li\u003e\n\u003cli\u003eThe condition and the dimensions of the roof curb, as well as the duct openings from underneath or from the side.\u003c\/li\u003e\n\u003cli\u003eThe lift, the service clearances around the cabinet and the condensate drainage.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eFrom the electrical service to the start-up, AirGreen takes care of everything\u003c\/h2\u003e\n\u003cp\u003eA single-phase packaged heat pump project calls for close coordination between the capacity of the unit, the electrical circuit and the roof. Our teams carry out the free on-site estimate, the load calculation for your space, the selection of the heat kit, the complete installation and the start-up. We then stay available for the regular maintenance of your unit: filters, belt, coils and a reading of the fault log. As a Montreal \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor, we work quickly and efficiently, scheduling the work around your business hours.\u003c\/p\u003e\n\u003cp\u003eIf your business is located in Montreal, Laval, Longueuil, on the North Shore or on the South Shore and is fed in single-phase only, call us at 514 316-2973 or fill out the form on airgreen.ca to book your free on-site estimate. We will propose a 4 ton solution suited to your electrical service.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367203942692,"sku":"WQE05A1B1AB5A111A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_609494b3-fbb6-4b68-8d92-440a9902a952.png?v=1790086673"},{"product_id":"thermopompe-monobloc-york-wqe-de-4-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WQE 4 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eClear data to manage a 4 ton rooftop unit\u003c\/h2\u003e\n\u003cp\u003eWhen a tenant reports that it is too warm, a building manager wants to know quickly what is happening on the roof: whether the unit is running normally, whether a safety has tripped or whether the airflow is adequate. For that kind of follow-up, the built-in control counts as much as the capacity. That is the strength of this WQE05A2B1AB5A111A1 model: a 4 ton YORK Sun Core \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e (48,000 BTU\/h nominal), in 208\/230 V three-phase, that records and displays what it is doing. AirGreen installs and maintains it in the commercial and rental buildings of Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003cp\u003eThe WQE series is the standard-efficiency version of the Sun Core line. It runs on R-454B, an A2L refrigerant with a low global warming potential, and receives its electric backup heat in the field.\u003c\/p\u003e\n\u003ch3\u003eWhat the LCD display shows right on the unit\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control has a readable LCD display, a navigation joystick and buttons. The technician goes through the menus quickly, right on the unit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe status of the unit and the function in progress (cooling, heating, ventilation);\u003c\/li\u003e\n\u003cli\u003ethe options configured at the factory;\u003c\/li\u003e\n\u003cli\u003ethe supply air, return air and outdoor air temperatures, measured by factory-installed sensors;\u003c\/li\u003e\n\u003cli\u003ethe fault codes and other operating information.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe USB port: history, reports and updates\u003c\/h3\u003e\n\u003cp\u003eAn ordinary USB key is all it takes to make use of the port built into the control board. It gives access to the data logging, to the current and previous faults, as well as to the self-test and start-up reports. The same port is used to update the control software. YORK adds energy consumption tracking functions, which allow operation to be adjusted to the time periods and the occupancy level of the building. For you, that means better documented service visits and decisions based on facts rather than on impressions.\u003c\/p\u003e\n\u003ch3\u003eProtections that leave a trace\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage monitoring:\u003c\/strong\u003e the control checks the supplied voltage and protects the unit in case of a voltage drop or another electrical anomaly.\u003c\/li\u003e\n\u003cli\u003eHigh and low pressure switches and temperatures monitored continuously, as are the high temperature limits when an electric heat kit is installed.\u003c\/li\u003e\n\u003cli\u003eThree-trip rule: the same safety has to trip three times within two hours before the compressor is locked out, which avoids service calls for an isolated trip.\u003c\/li\u003e\n\u003cli\u003eAnti-short-cycle delay and programmable minimum run times to spare the compressor, with a temporary bypass button during testing.\u003c\/li\u003e\n\u003cli\u003eProgrammable fan delays, independent in heating and in cooling.\u003c\/li\u003e\n\u003cli\u003eCooling possible down to 40 °F (4 °C) outdoors with no additional component, with the option of locking out the compressor in cold weather or when free cooling is available.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLinking the unit to your building management system\u003c\/h3\u003e\n\u003cp\u003eThe control works with a conventional thermostat wired to screw terminals, with a zone sensor, or in communication with a building management system. The YORK nomenclature confirms that this model is fitted with the BACnet MS\/TP, Modbus and N2 communication card. Your operating data can then travel up to the management station already in place, rather than staying on the roof. The code also provides for the refrigerant detection system (RDS), tied to the control, which starts a dilution sequence and an alarm in case of a leak.\u003c\/p\u003e\n\u003ch3\u003eOne cabinet, one place to watch\u003c\/h3\u003e\n\u003cp\u003eA packaged heat pump houses the whole system in an outdoor cabinet installed on the roof or at ground level: compressor, coils, fan, filters, control and backup heating elements. The building's duct system connects to it directly, on the supply as on the return. For a manager, this layout simplifies the follow-up: no indoor unit in a ceiling or a service room, and a single piece of equipment to inspect in order to understand how the system behaves.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eData\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e4 tons (48,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e48,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e45,600 BTU\/h, COP of 3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e24,600 BTU\/h, COP of 2.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2, HSPF2 and EER2\u003c\/td\u003e\n\u003ctd\u003e14.0, 6.7 and 12.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e1,550 CFM (ft³\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor blower\u003c\/td\u003e\n\u003ctd\u003eBelt drive, medium static pressure, 2.4 HP three-phase motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e208\/230 V three-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth x length x height\u003c\/td\u003e\n\u003ctd\u003e48.9 x 74.1 x 40.6 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e628 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor sound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e78.4 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField-installed backup heat\u003c\/td\u003e\n\u003ctd\u003eKits of 6.5, 10.5 or 16 kW at 230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eFor this configuration with no backup heat, YORK publishes a minimum circuit ampacity (MCA) of 22.2 A at 208 V and 22.5 A at 230 V; the fuse or the breaker must not exceed 30 A. A heat kit drives these values up, and the nameplate remains the reference.\u003c\/p\u003e\n\u003ch3\u003eA cabinet built to last on the roof\u003c\/h3\u003e\n\u003cp\u003eThe embossed top reinforces the structure and the rigidity of the cabinet, and the powder paint is rated 750 hours of salt spray. YORK tests and rates its units to cool up to 125 °F (52 °C) outdoor temperature. Its perimeter base rail fits many existing roof curbs, which makes replacing a unit at the end of its life easier.\u003c\/p\u003e\n\u003ch3\u003eA design that makes maintenance easier\u003c\/h3\u003e\n\u003cp\u003eThe 2 in. filters (four 16 x 16 x 2 in. filters, MERV 4 from the factory) are replaced through an access panel without tools, and MERV 8 or MERV 13 filters can be installed if needed. The large access panels clear the blower and its components, while the direct-drive outdoor fan, fastened to the grille, makes quick maintenance easier. A port provided in the top panel makes it possible to read the circuit pressures without removing the compressor access panel. As a factory option, hinged doors avoid having to remove panels on the roof, and a 120 V service outlet with a ground fault circuit interrupter stays within the technician's reach. The scroll compressor, the filter drier, the thermostatic expansion valve and the copper and aluminum coils round out a proven package. YORK configures every unit and puts it through a run test at the factory.\u003c\/p\u003e\n\u003ch3\u003eOur follow-up after the installation\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eCommissioning and keeping the start-up report produced by the control.\u003c\/li\u003e\n\u003cli\u003eSetting the fan delays and the parameters to your building's schedule.\u003c\/li\u003e\n\u003cli\u003eTesting the communication with your building management system, where applicable.\u003c\/li\u003e\n\u003cli\u003eScheduled maintenance visits, with filter replacement, belt check and review of the fault history.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eInstallation, commissioning and follow-up by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen sells and installs the YORK Sun Core line. Our crews take care of the free on-site estimate, the sizing, the complete installation, the commissioning and the maintenance. An \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor from Montreal, we work with building managers and general contractors so that every job is quick, efficient and well documented.\u003c\/p\u003e\n\u003cp\u003eBuilding managers in Montreal, Laval, Longueuil, the North Shore and the South Shore: for a rooftop unit that is easy to follow, call us at 514 316-2973 or fill out the form on airgreen.ca. We will quickly set the date of your free on-site estimate.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367203975460,"sku":"WQE05A2B1AB5A111A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_a43febbe-e4b8-401a-b335-16c8f45fe547.png?v=1790086674"},{"product_id":"thermopompe-monobloc-york-wqe-de-5-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WQE 5 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eBetter filtered and better renewed air for your business or your clinic\u003c\/h2\u003e\n\u003cp\u003eIn a clinic waiting room, a boutique with fitting rooms or a busy retail store, comfort is not limited to temperature. You also have to filter the air, bring in fresh air and protect the occupants. Model WQE06A2B1AB5A111A1, a 5 ton YORK Sun Core \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e (60,000 BTU\/h nominal) on 208\/230 V three-phase, lends itself well to these uses thanks to its upgradable filtration and to the economizers and safety options offered by YORK. Our crews install it in Montreal, in Laval and in Longueuil, as well as on the North Shore and the South Shore, in businesses as much as in clinics.\u003c\/p\u003e\n\u003cp\u003ePart of the WQE series, the standard efficiency version of the Sun Core line, this unit uses R-454B, an A2L refrigerant whose global warming potential is low. Its electric backup heat is added in the field.\u003c\/p\u003e\n\u003ch3\u003eFiltration: from MERV 4 to MERV 13 in the same filter rack\u003c\/h3\u003e\n\u003cp\u003eThe unit takes four 16 x 16 x 2 in. filters. It ships with MERV 4 disposable filters, and YORK provides for adding \u003cstrong\u003eMERV 8\u003c\/strong\u003e or \u003cstrong\u003eMERV 13\u003c\/strong\u003e filters through the filter access panel, which opens without tools, in particular to meet LEED requirements. A filter with a higher MERV rating holds back more fine particles, but it adds resistance to the passage of the air: we take that into account when we set the fan. According to the YORK nomenclature, this model is equipped with the medium static pressure option, that is a belt-driven centrifugal fan with a 2.4 HP three-phase motor and an adjustable motor sheave.\u003c\/p\u003e\n\u003ch3\u003eThe economizer: outdoor air up to 100%\u003c\/h3\u003e\n\u003cp\u003eAn economizer brings in outdoor air to ventilate the space and, when conditions allow, to cool it without putting the compressor to work. For this model, the economizer is installed in the field, in vertical flow (kit 2EE04711424) or horizontal flow (kit 2EE04707124 for the tall cabinet). Here is what the YORK guide says about it:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003elow-leakage AMCA 511 class 1A dampers, that is 3 CFM per square foot at 1 in. of static pressure;\u003c\/li\u003e\n\u003cli\u003e60,000 cycle endurance test for every economizer;\u003c\/li\u003e\n\u003cli\u003edry bulb temperature control as standard, with single (2EC0401) or dual (2EC0402) enthalpy kits;\u003c\/li\u003e\n\u003cli\u003efully modulating, spring-return actuators, able to bring in up to 100% outdoor air;\u003c\/li\u003e\n\u003cli\u003efull integration with the Smart Equipment control and a power exhaust offered to go with it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor simpler ventilation, YORK also offers manual outdoor air dampers from 0 to 35% or from 0 to 100%, as well as a motorized damper from 0 to 100%. One point worth knowing at the design stage: the pressure drop across the economizer is greater at 100% outdoor air than at 100% return air, and if the return duct resistance is below 0.25 in. of water column, the unit will deliver less airflow in full economizer mode.\u003c\/p\u003e\n\u003ch3\u003eDemand ventilation and integrated control\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control includes the economizer controller. According to YORK's specifications, it accepts a CO₂ sensor in the occupied space and it is ready for demand ventilation, which allows the fresh air supply to be matched to the actual traffic in the space. It can also lock out the compressor when free cooling is available. Supply, return and outdoor air temperature sensors are installed at the factory, and the LCD screen shows these readings as well as the fault codes. According to its nomenclature, this model includes the BACnet MS\/TP, Modbus and N2 communication card; a factory configuration without this card carries the number WQE06A2B1AA5A111A1.\u003c\/p\u003e\n\u003ch3\u003eOccupant safety and protection of the unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmoke detectors:\u003c\/strong\u003e offered for the supply air, the return air or both, they cut power to the unit and send a fault message to the control when they detect smoke.\u003c\/li\u003e\n\u003cli\u003eRefrigerant detection system (RDS) included according to the nomenclature: in the event of a leak, it triggers a dilution sequence and an alarm.\u003c\/li\u003e\n\u003cli\u003eNon-fused disconnect of 60 A or 100 A as a factory option; the model shown does not include one, and we then plan for an external disconnect of the appropriate rating.\u003c\/li\u003e\n\u003cli\u003eLouvered hail guard (kit 1HG0420) to protect the outdoor coil fins.\u003c\/li\u003e\n\u003cli\u003eInternally sloped condensate pan, made of a non-corrosive material and compliant with ASHRAE 62.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe packaged unit, a single air path to manage\u003c\/h3\u003e\n\u003cp\u003eThe principle is simple: the entire unit fits in an outdoor cabinet, installed on the roof or at ground level and connected to the building's ducts. The return air is filtered, cooled or heated there, then sent back by the fan to the supply ducts. The economizer mounts on the same cabinet, as does the power exhaust in the vertical configuration. The whole air path is therefore managed in one place, which simplifies filter maintenance and the ventilation settings.\u003c\/p\u003e\n\u003cp\u003eThe refrigeration side includes a single scroll compressor with protection against liquid-induced damage, a thermostatic expansion valve, a filter-drier and high and low pressure switches. The coils combine copper tubes and aluminum fins, and the cabinet's powder-coat finish is rated 750 hours in the salt spray test. A retail store sometimes has to be cooled as early as spring: the control allows cooling down to 40 °F (4 °C) outdoors with no additional component, and the economizer takes over with outdoor air when conditions allow.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated airflow: 1,550 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003eNet cooling (AHRI): 57,000 BTU\/h, for a rated capacity of 5 tons (60,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eHeating: 53,000 BTU\/h at 47 °F (8.3 °C), COP of 3.5; 29,000 BTU\/h at 17 °F (-8.3 °C), COP of 2.15\u003c\/li\u003e\n\u003cli\u003eEfficiency: 14.0 SEER2, 6.7 HSPF2 and 11.8 EER2\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eEnvelope (width x length x height): 48.9 x 74.1 x 40.6 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 627 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270): 77.8 dBA\u003c\/li\u003e\n\u003cli\u003eBackup heat: 6.5, 10.5 or 16 kW kits at 230 V, with reduced capacity at 208 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePlanning the installation in a space open to the public\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSite visit, load calculation and assessment of the fresh air needs based on occupancy.\u003c\/li\u003e\n\u003cli\u003eChoice of the filtration level, the economizer and the smoke detectors.\u003c\/li\u003e\n\u003cli\u003eCheck of the return ducts and adjustment of the fan for the target airflow.\u003c\/li\u003e\n\u003cli\u003eRespect of the 36 in. rear clearance required with an economizer or a power exhaust.\u003c\/li\u003e\n\u003cli\u003eLifting and installation scheduled outside busy hours, then commissioning.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eYour 5 ton project, from the estimate to the maintenance\u003c\/h2\u003e\n\u003cp\u003eAt AirGreen, the same team follows your file from start to finish: free on-site estimate, sizing, selection of the air quality options, installation, commissioning and maintenance. During maintenance, we replace the filters, check the economizer and review the control's history. As an \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor from Montreal, we favour fast, efficient work, scheduled to disturb your customers and your patients as little as possible.\u003c\/p\u003e\n\u003cp\u003eCall 514\u0026nbsp;316-2973 or write to us using the form on airgreen.ca: we will quickly schedule the free on-site estimate for your business or your clinic, in Montreal, in Laval, in Longueuil, on the North Shore as on the South Shore.\u003c\/p\u003e\n","brand":"York","offers":[{"title":"Default Title","offer_id":56367208005924,"sku":"WQE06A2B1AB5A111A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_f77934f2-c3d7-479e-8398-db3f3e1882da.png?v=1790086674"},{"product_id":"thermopompe-monobloc-york-wye-de-5-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WYE 5 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eWhen the electricity bill matters: the 5 ton high-efficiency version\u003c\/h2\u003e\n\u003cp\u003eIf you are the one paying the electricity for your business or your building, the purchase price of a rooftop unit is only part of the calculation. The unit will run for many years, in cooling as well as in heating, and a gain in efficiency carries over to every hour it operates. Model WYE06A2B1AB5A111A1 is the \u003cstrong\u003ehigh-efficiency\u003c\/strong\u003e version of the 5 ton YORK Sun Core packaged heat pump (60,000 BTU\/h nominal), in 208\/230 V three-phase and on R-454B refrigerant. AirGreen helps you compare it with the standard WQE06 version before you decide, for buildings in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eWYE06 and WQE06 side by side\u003c\/h3\u003e\n\u003cp\u003eBoth models share the same cabinet and the same design. Here are their main figures, taken from the YORK technical guide:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eWYE06 (high efficiency)\u003c\/th\u003e\n\u003cth\u003eWQE06 (standard efficiency)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e59,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e57,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e56,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP at 47 °F\u003c\/td\u003e\n\u003ctd\u003e3.6\u003c\/td\u003e\n\u003ctd\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e30,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e29,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOP at 17 °F\u003c\/td\u003e\n\u003ctd\u003e2.2\u003c\/td\u003e\n\u003ctd\u003e2.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e14.3\u003c\/td\u003e\n\u003ctd\u003e14.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2\u003c\/td\u003e\n\u003ctd\u003e6.9\u003c\/td\u003e\n\u003ctd\u003e6.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e12.0\u003c\/td\u003e\n\u003ctd\u003e11.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input in cooling (AHRI rating)\u003c\/td\u003e\n\u003ctd\u003e4.9 kW\u003c\/td\u003e\n\u003ctd\u003e4.8 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input in heating at 47 °F\u003c\/td\u003e\n\u003ctd\u003e4.5 kW\u003c\/td\u003e\n\u003ctd\u003e4.4 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower input in heating at 17 °F\u003c\/td\u003e\n\u003ctd\u003e4.1 kW\u003c\/td\u003e\n\u003ctd\u003e3.9 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e1,650 CFM\u003c\/td\u003e\n\u003ctd\u003e1,550 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum circuit ampacity (MCA) at 208 V, without backup heat\u003c\/td\u003e\n\u003ctd\u003e29 A\u003c\/td\u003e\n\u003ctd\u003e25.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor sound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e80.0 dBA\u003c\/td\u003e\n\u003ctd\u003e77.8 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e653 lb\u003c\/td\u003e\n\u003ctd\u003e627 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe MCA values correspond to the medium static pressure configuration of both models, without a powered convenience outlet.\u003c\/p\u003e\n\u003ch3\u003eHow to read these ratings\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2:\u003c\/strong\u003e seasonal cooling efficiency, that is the heat removed per unit of electricity consumed over a typical season.\u003c\/li\u003e\n\u003cli\u003eEER2: cooling efficiency at full load, measured at a high, fixed outdoor temperature; useful for judging performance in hot weather.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2:\u003c\/strong\u003e seasonal heating efficiency, calculated over a typical heating season.\u003c\/li\u003e\n\u003cli\u003eCOP: the instantaneous ratio between the heat delivered and the electricity consumed at a given outdoor temperature. At 47 °F (8.3 °C), a COP of 3.6 means 3.6 units of heat for every unit of electricity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat the comparison shows\u003c\/h3\u003e\n\u003cp\u003eThe WYE06 draws a little more at full load, but it also delivers more capacity in cooling and in heating. Efficiency is measured by the ratio between those two values, and the high-efficiency version earns a better rating on every count: SEER2, EER2, HSPF2 and COP. The advantage holds in cold weather: at 17 °F (-8.3 °C), it delivers 30,000 BTU\/h with a COP of 2.2. When the backup heat is called on, every extra BTU delivered by the heat pump cuts back its contribution by that much, and those electric elements only turn electricity into heat.\u003c\/p\u003e\n\u003cp\u003eThe comparison also shows three points to plan for: a slightly larger electrical circuit, 26 lb more on the roof and a higher sound rating. We take them into account, especially when the unit sits close to windows or to neighbouring dwellings. The real difference on your bill depends on your operating hours, your rate and the load of your building; we therefore assess it from your own situation rather than with a generic percentage.\u003c\/p\u003e\n\u003ch3\u003eWhen the high-efficiency version is worth it\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe space is occupied long hours, every day, in cooling as well as in heating.\u003c\/li\u003e\n\u003cli\u003eThe owner pays for the electricity directly and is keeping the building for the long term.\u003c\/li\u003e\n\u003cli\u003eThe heat pump carries a large share of the heating, which brings its COP of 3.6 and 2.2 into play.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor a space occupied few hours, or when the purchase budget comes first, the WQE06 can be enough. We compare both options with you, figures in hand.\u003c\/p\u003e\n\u003ch3\u003eThe settings that count as much as the rating\u003c\/h3\u003e\n\u003cp\u003eAn oversized unit starts and stops more often, which wastes part of its efficiency. We therefore begin with a load calculation. According to the YORK nomenclature, this model carries the medium static pressure option: a belt-driven fan, a 2.4 HP three-phase motor and an adjustable drive pulley, which we set to the target airflow after measuring the static pressure of your ducts.\u003c\/p\u003e\n\u003cp\u003eThanks to the energy consumption tracking built into the \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control, operation can be matched to the real schedule and occupancy of the building. The control can also lock out the compressor when free cooling is available with an economizer, and its fan delays are programmed separately in heating and in cooling. The LCD display, the USB port and, depending on the model code, the BACnet MS\/TP, Modbus and N2 communication card make monitoring easier. Finally, regular maintenance of the filters and the coils helps the unit keep its original performance.\u003c\/p\u003e\n\u003ch3\u003eA packaged unit assembled and tested at the factory\u003c\/h3\u003e\n\u003cp\u003eIn a packaged heat pump, compressor, coils, fan and control share a single outdoor cabinet, installed on the roof or on the ground and connected to the supply and return ducts. The refrigerant circuit is not joined in the field between two units: it is assembled at the factory, and every unit is configured and run-tested before delivery. The single scroll compressor, designed with fewer moving parts, contributes to a quiet, reliable, easy-to-service and efficient system.\u003c\/p\u003e\n\u003ch3\u003eEvery figure for the WYE06 model\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEfficiency ratings: 14.3 SEER2, 6.9 HSPF2 and 12.0 EER2\u003c\/li\u003e\n\u003cli\u003eCOP: 3.6 at 47 °F (8.3 °C) and 2.2 at 17 °F (-8.3 °C)\u003c\/li\u003e\n\u003cli\u003eNominal capacity: 5 tons (60,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 59,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating: 56,000 BTU\/h at 47 °F (8.3 °C) and 30,000 BTU\/h at 17 °F (-8.3 °C)\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 1,650 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eOverall dimensions (width x length x height): 48.9 x 74.1 x 40.6 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 653 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound rating (AHRI 270): 80.0 dBA\u003c\/li\u003e\n\u003cli\u003eField-installed backup heat: 6.5, 10.5 or 16 kW kits at 230 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSame dimensions, same roof curb\u003c\/h3\u003e\n\u003cp\u003eChoosing high efficiency does not complicate the installation. The WYE06 has the same dimensions as the WQE06 and uses the same 14 in. or 24 in. YORK roof curbs, the same hail guard and the same economizers. It also sits on a good number of existing roof curbs thanks to its full perimeter base rail. You find the construction shared across the line: thermostatic expansion valve, filter drier, high and low pressure switches, copper and aluminum coils, embossed top and powder paint rated for 750 hours of salt spray, all rated to cool up to 125 °F (52 °C).\u003c\/p\u003e\n\u003ch2\u003eChoosing the right efficiency level with AirGreen\u003c\/h2\u003e\n\u003cp\u003eBetween the standard version and the high-efficiency version, the right choice depends on your building, your occupancy hours and your electrical service. During the free on-site estimate, we run the load calculation, check the roof curb, the ducts and the electrical entrance, then we lay out both options transparently. Once your choice is made, we install the unit, commission it and maintain it. As a Montreal \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor, we work quickly and efficiently.\u003c\/p\u003e\n\u003cp\u003eOur on-site estimates are free everywhere in Montreal, Laval, Longueuil, the North Shore and the South Shore. Reach us at 514 316-2973 or through the form on airgreen.ca to compare both versions in your own building.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367208038692,"sku":"WYE06A2B1AB5A111A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_ef287294-da26-4414-be0f-81aa1f9d9ae4.png?v=1790086721"},{"product_id":"thermopompe-monobloc-york-xqe-de-4-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XQE 4 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eA 4 ton Sun Core unit that fits the roof curb already in place\u003c\/h2\u003e\n\u003cp\u003eYour business is fed with 208\/230 V three-phase power and you are looking for a reliable rooftop unit to cool in summer and heat in winter. The 4 ton YORK Sun Core XQE (48,000 BTU\/h nominal) is a \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e on R-410A, rated 13.4 SEER2, driven by the Smart Equipment control and built on a full-length base that fits many existing roof curbs. AirGreen, an HVAC contractor from Montreal, supplies and installs it for businesses in Laval, in Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\u003ch3\u003eDesigned for the replacement market\u003c\/h3\u003e\n\u003cp\u003eYORK designed the Sun Core line with the replacement market in mind: its \u003cstrong\u003eperimeter base rail\u003c\/strong\u003e fits many roof curbs already in place. The rails, made of heavier steel, are shaped to stand up to transport and lifting. They surround the unit on four sides, with holes for lifting shackles and openings for the forklift.\u003c\/p\u003e\n\u003cp\u003eSince compatibility depends on the existing curb, we always measure it during the estimate. If a new curb is preferable, YORK offers 14 or 24 in. curbs, shipped knocked down, with insulated decking and a wood nailer strip around the full perimeter. They carry the entire weight of the unit, and the ducts can be attached to them before the unit is set in place.\u003c\/p\u003e\n\u003ch3\u003eWhat \"packaged\" means for a business\u003c\/h3\u003e\n\u003cp\u003eIn a packaged unit, the whole system sits in a single outdoor cabinet: scroll compressor, copper and aluminum coils, fans, filters and control. Nothing takes up your sales floor or your stockroom. The unit connects to the supply and return ducts and, thanks to the heat pump mode, it heats in winter and cools in summer.\u003c\/p\u003e\n\u003cp\u003eConfigured at the factory for bottom supply and return, it converts in the field to horizontal connections. A mixed arrangement is also possible: bottom supply and horizontal return, or the other way around. This flexibility helps reuse the existing ducts.\u003c\/p\u003e\n\u003ch3\u003ePerformance rated under the SEER2 standard\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated capacity:\u003c\/strong\u003e 4 tons (48,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI net cooling:\u003c\/strong\u003e 48,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating at 47 °F (8.3 °C):\u003c\/strong\u003e 46,700 BTU\/h, COP of 3.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating at 17 °F (-8.3 °C):\u003c\/strong\u003e 26,400 BTU\/h, COP of 2.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2 ratings:\u003c\/strong\u003e SEER2 13.4, HSPF2 6.7 and EER2 12.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatings under the previous standard:\u003c\/strong\u003e SEER 14.5 and HSPF 8.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated airflow:\u003c\/strong\u003e 1,550 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 208\/230 V, three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (width x length x height):\u003c\/strong\u003e 48.9 x 74.1 x 40.6 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating weight:\u003c\/strong\u003e 628 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor sound level (AHRI 270):\u003c\/strong\u003e 78.4 dB(A)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R-410A, the previous-generation refrigerant with proven technology\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSmart Equipment: the control at the heart of the unit\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control comes standard on the XQE. It works with a conventional 24 V thermostat, a zone sensor or, with the communication card offered as a factory option, a building management system on BACnet MS\/TP, Modbus or N2. Three temperature sensors, installed at the factory, read supply air, return air and outdoor air.\u003c\/p\u003e\n\u003cp\u003eThe LCD display, with its navigation joystick, shows unit status, measured temperatures and alarms. The USB port allows data logging, review of current and previous faults, software updates and energy consumption tracking. The control also monitors the supply voltage and protects the unit in the event of a voltage drop. Finally, it applies a short-cycle delay and programmable fan delays, separate for heating and cooling.\u003c\/p\u003e\n\u003cp\u003eOffered as a factory option or as an accessory, the fault detection and diagnostics (FDD) module continuously monitors the pressures and temperatures of the refrigerant circuit. It raises an alarm when the unit is not running at its best, and its data can be reached remotely through the Mobile Access Portal gateway.\u003c\/p\u003e\n\u003ch3\u003eSimple, rugged mechanics\u003c\/h3\u003e\n\u003cp\u003eOn the 3 to 5 ton models, YORK uses a single refrigeration circuit and a single \u003cstrong\u003escroll compressor\u003c\/strong\u003e. The scroll has a simple internal design, with fewer moving parts, which makes it quiet, reliable and easy to service. The compressor is internally protected, in particular against liquid-induced damage. Each circuit includes a filter-drier and high and low pressure switches, while sensors on the suction line guard against liquid floodback, loss of charge and coil frosting.\u003c\/p\u003e\n\u003cp\u003eThe outdoor fan, dynamically balanced, contributes to the quieter operation of the unit. The embossed top adds rigidity to the cabinet, and the powder-coat finish withstands 750 hours of salt spray exposure. YORK tests and rates these units in cooling up to 125 °F (52 °C) outdoors. At the other end, the built-in low ambient control allows cooling down to 40 °F (4 °C) with no additional component.\u003c\/p\u003e\n\u003ch3\u003eVentilation and air quality\u003c\/h3\u003e\n\u003cp\u003eThe XQE comes with four 2 in. disposable filters (16 x 16 x 2 in.) rated MERV 4. MERV 8 or MERV 13 filters install easily through the filter access panel, which opens without tools. For fresh air, YORK offers economizers installed at the factory or in the field, able to bring in up to 100% outdoor air, along with manual adjustable dampers from 0 to 35% or from 0 to 100% and a motorized damper. The control accepts a CO2 sensor for ventilation based on occupancy.\u003c\/p\u003e\n\u003ch3\u003eElectric backup heat\u003c\/h3\u003e\n\u003cp\u003eThe heat pump delivers 46,700 BTU\/h at 47 °F (8.3 °C) and 26,400 BTU\/h at 17 °F (-8.3 °C). For colder days, the electric heat for the XQE is installed in the field. On 208\/230 V three-phase, the YORK guide offers 6.5, 10.5 and 16 kW kits at 230 V, which give 4.9, 7.9 and 12 kW respectively at 208 V. The required hardware and connectors are supplied with each kit. If you go with the non-fused disconnect offered from the factory (60 or 100 A), we check that it suits the kit you choose.\u003c\/p\u003e\n\u003ch3\u003ePoints to settle before ordering\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMeasure the existing roof curb and the position of the supply and return openings.\u003c\/li\u003e\n\u003cli\u003eCheck the three-phase supply, which must stay between 187 and 252 V according to the YORK guide.\u003c\/li\u003e\n\u003cli\u003eMinimum clearances: 12 in. on the left and 18 in. on the right, 36 in. at the front, 72 in. clear above for air discharge, and 18 in. at the rear, raised to 36 in. with an economizer or a power exhaust.\u003c\/li\u003e\n\u003cli\u003eConsider the through-the-base electrical connection kit, which brings the power in without any additional roof penetration.\u003c\/li\u003e\n\u003cli\u003ePlan the crane lift using the holes provided in the base rails.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eAirGreen, your contractor for commercial roofs\u003c\/h2\u003e\n\u003cp\u003eChoosing the right rooftop unit starts with measuring properly. During our \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, we check the curb, the ducts, the electrical service and the heating needs of your business. We size the unit and the backup kit, then our crews take care of the lifting, the installation, the commissioning and the periodic maintenance.\u003c\/p\u003e\n\u003cp\u003eAirGreen serves Montreal, Laval, Longueuil, the North Shore and the South Shore. For your 4 ton YORK Sun Core XQE packaged heat pump, reach our team at 514\u0026nbsp;316-2973 or request your estimate online at airgreen.ca. We will call you back quickly.\u003c\/p\u003e\n","brand":"York","offers":[{"title":"Default Title","offer_id":56367217869092,"sku":"XQE05A2C1AA1B111A3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_ff7e6a46-f4ee-46b6-b771-403d11977b52.png?v=1790086770"},{"product_id":"thermopompe-monobloc-york-xqe-de-5-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XQE 5 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eA roof that is hard to reach: 5 tons built for quick maintenance\u003c\/h2\u003e\n\u003cp\u003eOn many buildings, the roof is reached by a ladder and a hatch, and every service call has to be short and well prepared. The 5 ton YORK Sun Core XQE (60,000 BTU\/h nominal) answers that reality: a \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e on R-410A, fed in 208\/230 V three-phase, in a compact cabinet with wide service access and filters that change without a tool. AirGreen, an HVAC contractor in Montreal, installs and maintains it in Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\u003ch3\u003eWhen every trip to the roof counts\u003c\/h3\u003e\n\u003cp\u003eLimited access does not change what a rooftop unit needs in maintenance: filters, coils, belt, reading the pressures and checking the protections. It does change what each visit costs in time. Hence the value of a unit where everything sits in the same place and where the routine steps go quickly, without taking apart more than necessary.\u003c\/p\u003e\n\u003ch3\u003eA compact, small-footprint cabinet\u003c\/h3\u003e\n\u003cp\u003eThe 5 ton XQE uses what the Sun Core line calls the \u003cstrong\u003esmall footprint\u003c\/strong\u003e cabinet: 48.9 in. wide, 74.1 in. long and 40.6 in. high, for an operating weight of 627 lb. The one-piece top panel is embossed to stiffen the cabinet. The base rails run around all four sides of the unit and are drilled to take lifting shackles and the forks of a lift truck. A single crane lift is enough to set it in place.\u003c\/p\u003e\n\u003ch3\u003eService access that is wide and well thought out\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge access panels:\u003c\/strong\u003e the indoor blower, rigidly mounted and dynamically balanced, is reached through wide panels that come off easily.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in handles:\u003c\/strong\u003e the panels of the control box, of the indoor blower, of its motor and of the compressor have handles in UV-treated composite, permanently fixed and recessed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaceable collars:\u003c\/strong\u003e the panel screws thread into heat-resistant composite collars that are easy to replace.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePressure readings:\u003c\/strong\u003e a port closed by a removable plug lets us connect the gauges and read the head pressure without removing the compressor panel.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor fan:\u003c\/strong\u003e direct drive, mounted to the grille, it is quick to service.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHinged doors:\u003c\/strong\u003e offered as a factory option, they save removing the panels, and therefore misplacing them or damaging the roof covering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFilters that change without a tool\u003c\/h3\u003e\n\u003cp\u003eThe filter access panel, installed at the factory, opens without a tool. The four 2 in. disposable filters are all the same size, 16 x 16 x 2 in.: a single dimension to carry up to the roof. Supplied in MERV 4, they can give way to MERV 8 or MERV 13 filters, slid in through the same panel. If the unit receives a horizontal-flow economizer, YORK offers a hinged filter access panel designed for that configuration.\u003c\/p\u003e\n\u003ch3\u003eDiagnosing quickly, on site or remotely\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control, standard, shows on its LCD display the operating status, the air temperatures (supply, return, outdoor) and the alarm codes. The last five codes are held in non-volatile memory, which a power failure does not erase. Through the USB port, the technician downloads the data log and the start-up reports. Before locking out the compressor, the control waits for three trips of the same protection within two hours, which cuts down on needless calls.\u003c\/p\u003e\n\u003cp\u003eTo limit the trips, two factory options deserve your attention: the BACnet MS\/TP, Modbus or N2 communication card to link the unit to your building management system, and the FDD module, which monitors the refrigerant circuit and whose data can be consulted remotely through the Mobile Access Portal gateway.\u003c\/p\u003e\n\u003ch3\u003eFewer unplanned visits\u003c\/h3\u003e\n\u003cp\u003eOn a roof that is hard to reach, the best visit is the one you do not have to make. The \u003cstrong\u003escroll compressor\u003c\/strong\u003e of the XQE has a simple internal design and internal protection that shields it from liquid slugging. The control monitors the supply voltage and protects the unit during a voltage drop. Every unit goes through an automated run test on the assembly line, and YORK keeps the data from that test at the factory. The galvanized steel cabinet, finished with a powder paint proven through 750 hours of salt spray, is built to the UL 1995 standard, which includes a rain resistance test.\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eXQE 5 ton, 208\/230 V three-phase\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e5 tons (60,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e57,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e30,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 ratings\u003c\/td\u003e\n\u003ctd\u003eSEER2 13.4, HSPF2 6.7, EER2 11.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRatings under the former standard\u003c\/td\u003e\n\u003ctd\u003eSEER 14.5, HSPF 8.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e1,640 CFM (ft³\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, three-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (width x length x height)\u003c\/td\u003e\n\u003ctd\u003e48.9 x 74.1 x 40.6 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e627 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor sound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e77.8 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003eR-410A (previous generation, proven technology)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eThe packaged unit: a single machine to maintain\u003c\/h3\u003e\n\u003cp\u003eA packaged unit brings together in a single outdoor cabinet the scroll compressor, the indoor coil, the outdoor coil, the fans, the filters and the control, all connected to the building's ducts. For a roof that is hard to reach, that is a clear advantage: one visit covers the whole system, and no indoor unit is hidden in a ceiling. In the field, what is left is to connect the ducts, the power, the control wiring and the condensate drain (3\/4 in. NPT fitting, from underneath or from the side of the pan).\u003c\/p\u003e\n\u003ch3\u003eHeating and electric backup\u003c\/h3\u003e\n\u003cp\u003eThe heat pump delivers 54,500 BTU\/h at 47 °F (8.3 °C) and 30,600 BTU\/h at 17 °F (-8.3 °C). To top up the heat in very cold weather, YORK offers field-installed \u003cstrong\u003eelectric heat\u003c\/strong\u003e kits: 6.5, 10.5 or 16 kW at 230 V, that is 4.9, 7.9 or 12 kW at 208 V. We choose the kit according to the heat loss of the building.\u003c\/p\u003e\n\u003ch3\u003ePlanning the lift and the clearances\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eBook the crane and check the lift path over the building.\u003c\/li\u003e\n\u003cli\u003eLeave 36 in. at the front and 72 in. above the unit.\u003c\/li\u003e\n\u003cli\u003eAllow 18 in. on the right, 12 in. on the left and 18 in. at the back, or 36 in. with an economizer or a powered exhaust.\u003c\/li\u003e\n\u003cli\u003eBring the power in through the base with the watertight connection kit, without an additional penetration in the roof.\u003c\/li\u003e\n\u003cli\u003eConsider the louvred hail guard, which protects the fins of the outdoor coil.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eOne point of contact for your rooftop unit\u003c\/h2\u003e\n\u003cp\u003eWe know that a roof that is hard to reach calls for preparation. Our \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e includes a survey of the roof access, the curb, the ducts and the electrical entrance. We then size the unit and the electric backup, and our crews coordinate the lift, carry out the installation and the commissioning, and handle the scheduled maintenance.\u003c\/p\u003e\n\u003cp\u003eOur crews travel to Montreal, Laval, Longueuil, the North Shore and the South Shore. Call 514 316-2973 or write to us from the form on airgreen.ca: we will schedule your visit quickly.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367218360612,"sku":"XQE06A2B1AA1A111A3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_14a5638c-ce50-4772-a8b0-f350b3f29b67.png?v=1790086771"},{"product_id":"thermopompe-monobloc-york-xqe-de-5-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XQE 5 Ton 575V | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eComfort for factory offices, on a 575 V supply\u003c\/h2\u003e\n\u003cp\u003eIn a factory or a warehouse, the production floor has its own systems, but the offices, the cafeteria and the control room need steady comfort, summer and winter. The 5 ton YORK Sun Core XQE (60,000 BTU\/h nominal) in its 575 V three-phase version is an R-410A \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e that connects directly to the electrical distribution of your industrial building. AirGreen, an HVAC contractor in Montreal, installs it in the industrial sectors of Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eThree spaces, three ways to use the same unit\u003c\/h3\u003e\n\u003ch4\u003eThe offices\u003c\/h4\u003e\n\u003cp\u003eOccupied on a fixed schedule, offices benefit from a programmable thermostat with an occupancy schedule. The Smart Equipment control accepts a conventional 24 V thermostat or a zone sensor, and the fan delays are adjusted independently for heating and for cooling.\u003c\/p\u003e\n\u003ch4\u003eThe cafeteria\u003c\/h4\u003e\n\u003cp\u003eAt mealtime, occupancy climbs all at once. An \u003cstrong\u003eeconomizer\u003c\/strong\u003e can bring in up to 100% outdoor air, and a CO2 sensor wired to the control allows ventilation based on demand. YORK also offers powered exhaust fans in 575 V, which push out the excess air when the economizer is open.\u003c\/p\u003e\n\u003ch4\u003eThe control room\u003c\/h4\u003e\n\u003cp\u003eThe equipment in it gives off heat in every season. Thanks to the built-in low-ambient control, the XQE cools down to 40 °F (4 °C) outdoors, with no added component. To go lower, YORK offers a head pressure control kit, installed in the field, that varies the airflow through the outdoor coil. If the room houses critical equipment, we confirm the application with you before choosing the unit.\u003c\/p\u003e\n\u003ch3\u003eA direct 575 V supply\u003c\/h3\u003e\n\u003cp\u003eBuilt at the factory for 575 V three-phase (60 Hz), the unit accepts, according to the YORK guide, an applied voltage between 540 and 630 V. For backup heat, two electric kits of 13.8 kW and 23 kW are offered in 575 V for this model. They are installed in the field, with the hardware and connectors supplied.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eNon-fused disconnect switch of 60 or 100 A offered as a factory option, with its rating checked against the heat kit selected\u003c\/li\u003e\n\u003cli\u003eThrough-the-base electrical entry kit, which avoids drilling the roof one more time\u003c\/li\u003e\n\u003cli\u003e120 V receptacle protected by a ground-fault circuit interrupter, offered as a factory option, powered by the unit or wired in the field\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHeating the spaces in winter\u003c\/h3\u003e\n\u003cp\u003eIn heat pump mode, the XQE delivers 54,500 BTU\/h when it is 47 °F (8.3 °C) outdoors, and still 30,600 BTU\/h at 17 °F (-8.3 °C). The capacity of a heat pump drops as it gets colder: the 13.8 kW or 23 kW kit then covers the difference. We choose it from the heat loss of the offices and the cafeteria, taking into account the dock doors or the partitions that separate them from the warehouse.\u003c\/p\u003e\n\u003ch3\u003eFiltration in a dusty environment\u003c\/h3\u003e\n\u003cp\u003eAs standard, the unit takes four 16 x 16 x 2 in. MERV 4 disposable filters. Where production dust travels, we can move up to a MERV 8 or MERV 13 rating, installed through the tool-less filter access panel. We then match the replacement interval to the reality of your building.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal capacity: 5 tons (60,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 57,400 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 54,500 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 30,600 BTU\/h\u003c\/li\u003e\n\u003cli\u003eEfficiency: SEER2 13.4, HSPF2 6.7 and EER2 11.9 (SEER 14.5 and HSPF 8.25 under the previous standard)\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 1,640 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 575 V, three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 48.9 x 74.1 x 40.6 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 627 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270): 77.8 dB(A)\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-410A (previous-generation refrigerant, proven technology)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBuilt to last in an industrial environment\u003c\/h3\u003e\n\u003cp\u003eOn the galvanized steel of the cabinet, YORK applies a powder paint that has passed the 750 hour salt spray test of the ASTM B117 standard. As an option, an epoxy polymer \u003cstrong\u003eE-Coat\u003c\/strong\u003e coating protects the indoor and outdoor coils against corrosion and limits galvanic action between aluminum and copper. The standard coils are leak checked at 150 psig and pressure tested, at 450 psig for the indoor coil and at 650 psig for the outdoor coil.\u003c\/p\u003e\n\u003cp\u003eAssembled in Norman, Oklahoma, in an ISO 9001 registered plant, every unit goes through a fully automated run test at the end of the line. YORK also puts it through a vibration test to the ASTM D4169 standard to make shipping more reliable, and it is certified to the CSA C22.2 No. 236 (UL 1995) standard. Supply air or return air smoke detectors, which stop the unit when smoke is present, and burglar bars for the duct openings round out the offering.\u003c\/p\u003e\n\u003ch3\u003eWhy a packaged heat pump in an industrial building\u003c\/h3\u003e\n\u003cp\u003eThe packaged heat pump holds the whole system in a single cabinet set on the roof: scroll compressor, coils, fans, filters and control. The ducts run down to the offices, the cafeteria or the control room, with no refrigerant line inside the plant and no unit hanging above the workstations. The same unit cools in summer and heats in winter.\u003c\/p\u003e\n\u003ch3\u003eSmart Equipment and building integration\u003c\/h3\u003e\n\u003cp\u003eAs standard, the \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control provides an LCD screen, a USB port for data logging and updates, as well as three factory-installed sensors (supply air, return air and outdoor air). If your plant has a building management system, a communication card (BACnet MS\/TP, Modbus or N2), offered as a factory option, lets you follow the unit from that system. The FDD module, offered as an option, watches the refrigerant circuit and reports any abnormal operation. Another protection that is useful on an industrial electrical network: the control detects voltage drops and puts the unit out of harm's way.\u003c\/p\u003e\n\u003ch3\u003eSteps of a 575 V project\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVisit of the spaces to be served and load calculation for each space.\u003c\/li\u003e\n\u003cli\u003eVerification of the 575 V circuit, the disconnect switch and the backup heat kit.\u003c\/li\u003e\n\u003cli\u003eChoice of the roof curb: YORK curbs of 14 or 24 in., with insulated decks, shipped knocked down.\u003c\/li\u003e\n\u003cli\u003eCrane lift of the 627 lb unit, by the lifting points on the base rails.\u003c\/li\u003e\n\u003cli\u003eClearances: 36 in. at the front, 12 in. on the left, 18 in. on the right, 72 in. above and, at the back, 18 in. or 36 in. if the unit takes an economizer or a powered exhaust fan.\u003c\/li\u003e\n\u003cli\u003eStart-up and schedule programming with your team.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eAirGreen supports industrial buildings\u003c\/h2\u003e\n\u003cp\u003eWe sell and install rooftop units for the factories, warehouses and businesses of the greater Montreal area: Laval, Longueuil, the North Shore and the South Shore. The starting point: a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, during which we visit the offices, the cafeteria and the control room, then check the 575 V service and the roof. We then set the size of the unit and of the electric backup heat, and our teams take care of the installation, the start-up and the maintenance.\u003c\/p\u003e\n\u003cp\u003eTo start your project, call 514 316-2973 or fill out our form on airgreen.ca: a member of our team will get back to you quickly.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367218393380,"sku":"XQE06A5C1AA1B111A3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_934f7da3-1441-492b-b530-5a1ffd30939c.png?v=1790086771"},{"product_id":"thermopompe-monobloc-york-xye-de-6-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XYE 6 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eMoving up to 6 tons without giving up comfort on quiet days\u003c\/h2\u003e\n\u003cp\u003eWhen a commercial space goes beyond what a 5 ton unit can cover, it is tempting to go bigger and accept a unit that starts and stops constantly on mild days. This 6 ton YORK Sun Core XYE packaged heat pump avoids that compromise: its \u003cstrong\u003etwo-stage scroll compressor\u003c\/strong\u003e works at 67% or at 100% of its capacity depending on demand, and its \u003cstrong\u003eIEER of 16.5\u003c\/strong\u003e shows its performance at part load. For a large store, open-plan offices, a clinic or a training studio fed in 208\/230 V three-phase, AirGreen offers and installs it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eTwo stages in a single compressor: 67% or 100%, depending on demand\u003c\/h3\u003e\n\u003cp\u003eIn the XYE line, the 3 to 5 ton models have only one cooling stage. The 6 ton is the first to offer two, through a single two-stage scroll compressor. When the load is moderate, it runs at 67% of its capacity rather than swinging between a full stop and full output; at peak hours, it steps up to 100%. The unit also has two 22 in. two-speed outdoor fans.\u003c\/p\u003e\n\u003cp\u003eThis behaviour explains the gap between the two efficiency ratings. The \u003cstrong\u003eEER of 12.0\u003c\/strong\u003e measures performance at full load; the IEER of 16.5, obtained with the IntelliSpeed drive, takes part-load operation into account. Like every unit of 6 tons and up, the XYEA7 is rated in EER and IEER, and not in SEER or HSPF.\u003c\/p\u003e\n\n\u003ch3\u003eA packaged heat pump in the large Sun Core cabinet\u003c\/h3\u003e\n\u003cp\u003eThe principle does not change: a \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e brings compressor, coils, fans and control together in a single outdoor cabinet, set on the roof or on the ground and connected to the building's ducts. It cools in summer and heats by heat pump the rest of the year. What changes at 6 tons is the size: the XYEA7 moves up to the large Sun Core cabinet of 61.7 x 87.2 in., in its low 40.6 in. version, and it shares the roof curb of the 7.5 to 10 ton models.\u003c\/p\u003e\n\u003cp\u003eThe XYE series is the high-efficiency version of the Sun Core line. It uses \u003cstrong\u003eR-410A\u003c\/strong\u003e, the previous generation refrigerant: a proven technology that technicians know well.\u003c\/p\u003e\n\n\u003ch3\u003eThe XYEA7 figures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal capacity: 6 tons (72,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 70,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 67,000 BTU\/h, COP of 3.4\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 38,000 BTU\/h, COP of 2.4\u003c\/li\u003e\n\u003cli\u003eEER of 12.0 and IEER of 16.5\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 2,440 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V, three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eCompressor: 1 two-stage scroll (67% \/ 100%)\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 61.7 x 87.2 x 40.6 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 898 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270): 83 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat the XYEA7A2B3AA1C111A2 configuration includes\u003c\/h3\u003e\n\u003cp\u003eRead against the nomenclature of the Sun Core technical guide, this model number describes the following equipment:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBelt-driven indoor blower, medium static pressure option.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e, which adjusts the supply fan speed according to the compressor or heating stage that is running.\u003c\/li\u003e\n\u003cli\u003eFactory-installed enthalpy economizer.\u003c\/li\u003e\n\u003cli\u003eSmart Equipment control, with factory-installed supply, return and outdoor air sensors.\u003c\/li\u003e\n\u003cli\u003eStandard indoor and outdoor coils, without E-Coat coating.\u003c\/li\u003e\n\u003cli\u003eNo disconnect switch, no convenience outlet and no factory electric heat: these are added in the field as needed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEnthalpy economizer and IntelliSpeed: fresh air at the right moment\u003c\/h3\u003e\n\u003cp\u003eThe economizer on this model does not simply measure the outdoor temperature: its enthalpy sensor allows free cooling when the enthalpy of the outdoor air, which accounts for its humidity, is below the setpoint. Its low-leakage dampers (AMCA 511, class 1A) admit up to 100% outdoor air, and a dual enthalpy kit, installed in the field, can add a reading on the return air. Meanwhile, the IntelliSpeed drive modulates the airflow, and the minimum position of the economizer remains configurable.\u003c\/p\u003e\n\n\u003ch3\u003eThe Sun Core details that make maintenance easier\u003c\/h3\u003e\n\u003ch4\u003eFilters reached without a tool\u003c\/h4\u003e\n\u003cp\u003eThe XYEA7 takes four 16 x 20 x 2 in. filters, supplied as disposable MERV 4. MERV 8 or MERV 13 filters slide in easily through the tool-free access panel, a sound choice for a clinic or busy offices.\u003c\/p\u003e\n\u003ch4\u003eCoils and refrigerant circuit\u003c\/h4\u003e\n\u003cp\u003eThe coils, in copper tube with aluminum fins, are fed by a thermostatic expansion valve (TXV). The outdoor coil, with three rows, offers 21 ft² of surface, and the indoor coil, with four rows, 8.9 ft². A drier on the liquid line, high and low pressure switches and sensors on the suction line, which protect against liquid return, loss of refrigerant and coil frosting, complete the package.\u003c\/p\u003e\n\u003ch4\u003eA control you can read\u003c\/h4\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e board shows on its LCD display the status of the unit, the temperatures and the fault codes. Its USB port serves the fault history, the updates and the start-up reports, and a short-cycle protection with a minimum run time spares the compressor.\u003c\/p\u003e\n\u003ch4\u003eA rugged build\u003c\/h4\u003e\n\u003cp\u003eAssembled in Norman, Oklahoma, the unit has an embossed top for rigidity and a powder paint rated for 750 hours of salt spray. Every unit is commissioned, configured and tested at the factory.\u003c\/p\u003e\n\n\u003ch3\u003ePlanning the installation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof curb:\u003c\/strong\u003e the YORK curbs for the large cabinet are the 1RC0457 (14 in.) and the 1RC0459 (24 in.). If the unit being replaced sat on a small-size curb, we check the fit on site and plan a new curb if needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e applied voltage from 187 to 252 V; the disconnect switch is planned for the field.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackup heat:\u003c\/strong\u003e three field-installed kits are available for this model in 208\/230 V, from 6.5 to 24.8 kW at 230 V (4.9 to 18.6 kW at 208 V).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 72 in. above, 48 in. at the front, 36 in. at the back with an economizer, 18 in. on the right and 12 in. on the left.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e air openings convertible from vertical to horizontal, and a through-the-base electrical connection kit (1TB0404) offered to avoid another penetration in the roof.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eAirGreen guides you through the move to 6 tons\u003c\/h2\u003e\n\u003cp\u003eThe right choice between 5, 6 and 7.5 tons is made on site. During the \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, we calculate the load of your space, look at the ducts, the electrical service and the existing roof curb, then we give you a clear recommendation. Our crews install the unit, set up the economizer, the IntelliSpeed drive and the Smart Equipment control, and then provide scheduled maintenance.\u003c\/p\u003e\n\u003cp\u003eWhether your business is in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, our HVAC team works quickly and efficiently. Call 514 316-2973 or fill out the form on airgreen.ca to get your quote.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367218819364,"sku":"XYEA7A2B3AA1C111A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_6_A_10_TONNES_00_PRINCIPALE_b7ccc18b-fe25-43a2-87c8-db92b56ac6b8.png?v=1790086820"},{"product_id":"thermopompe-monobloc-york-xxe-de-7-5-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XXE 7.5 Ton 575V | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eWarehouse, workshop or reception hall: 7.5 tons in 575 V for large spaces\u003c\/h2\u003e\n\u003cp\u003eLarge spaces each have their own rhythm. A warehouse holds a fairly steady load, a workshop builds up the heat of its machines, and a reception hall goes in a few minutes from an empty room to a crowd of guests. The 7.5 ton YORK Sun Core XXE packaged heat pump answers these three situations with \u003cstrong\u003etwo scroll compressors\u003c\/strong\u003e, two stages of cooling and an \u003cstrong\u003eIEER of 15.1\u003c\/strong\u003e, on a \u003cstrong\u003e575 V three-phase\u003c\/strong\u003e supply. AirGreen installs it in the commercial and industrial buildings of Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eThree large spaces, three ways to benefit from two stages\u003c\/h3\u003e\n\u003ch4\u003eThe warehouse\u003c\/h4\u003e\n\u003cp\u003eWith low occupancy and moderate heat gains, the first compressor, that is half the capacity, can be enough. In the shoulder seasons, the economizer takes over with cool outdoor air when conditions allow it.\u003c\/p\u003e\n\u003ch4\u003eThe workshop\u003c\/h4\u003e\n\u003cp\u003eThe equipment, the lighting and the door openings make the load vary through the shift. The second compressor starts when the temperature climbs, then stops when demand comes back down.\u003c\/p\u003e\n\u003ch4\u003eThe reception hall\u003c\/h4\u003e\n\u003cp\u003eHere, the load changes all at once when the guests arrive. The two stages make it possible to cool the hall at partial capacity before the event, then to move to full capacity as it fills up.\u003c\/p\u003e\n\u003cp\u003eIn all three cases, the \u003cstrong\u003eEER of 11.5\u003c\/strong\u003e measures the efficiency at full load, while the IEER of 15.1, obtained with the IntelliSpeed drive, takes part-load operation into account. This 7.5 ton model is rated in EER and IEER, not in SEER.\u003c\/p\u003e\n\n\u003ch3\u003eA packaged unit on the roof, tied to the 575 V network\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e holds the whole system in a single outdoor cabinet: the two compressors, the coils, the fans and the control board. On the roof or on a pad, it connects to the supply and return ducts, cools in summer and heats by heat pump the rest of the year. In a building supplied at 575 V, it connects to the existing distribution, within an applied voltage range of 540 to 630 V according to the YORK guide. It runs on \u003cstrong\u003eR-410A\u003c\/strong\u003e, a previous-generation refrigerant and a proven technology, and each compressor feeds its own independent refrigerant circuit.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal capacity:\u003c\/strong\u003e 7.5 tons (90,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI net cooling:\u003c\/strong\u003e 90,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating at 47 °F (8.3 °C):\u003c\/strong\u003e 84,000 BTU\/h, COP of 3.5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating at 17 °F (-8.3 °C):\u003c\/strong\u003e 49,000 BTU\/h, COP of 2.25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e EER of 11.5, IEER of 15.1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal airflow:\u003c\/strong\u003e 3,300 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 575 V, three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompressors:\u003c\/strong\u003e 2 scroll, steps of 50% and 100%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions (width x length x height):\u003c\/strong\u003e 61.7 x 87.2 x 48.6 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating weight:\u003c\/strong\u003e 976 lb\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor sound level (AHRI 270):\u003c\/strong\u003e 83.2 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe XXE08A5B3AA1B111A2 configuration\u003c\/h3\u003e\n\u003cp\u003eAccording to the Sun Core nomenclature, this model is delivered with a medium static pressure belt-drive indoor fan, an \u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e, a dry bulb economizer, the Smart Equipment control and standard coils. It includes no convenience receptacle, no disconnect switch and no factory electric heat: those items are planned in the field, according to the needs of your building. The supply, return and outdoor air temperature sensors are installed at the factory.\u003c\/p\u003e\n\n\u003ch3\u003eEconomizer and variable-speed drive: fresh air managed precisely\u003c\/h3\u003e\n\u003cp\u003eThe dry bulb economizer turns on free cooling when the outdoor temperature drops below its setpoint. Its low-leakage dampers, certified AMCA 511 class 1A, can bring in up to 100% outdoor air, and single or dual enthalpy kits, installed in the field, can refine the changeover based on humidity. For a full reception hall or a workshop, a powered exhaust fan in 575 V, designed for the large cabinet, can be added. The IntelliSpeed drive, for its part, varies the speed of the supply fan according to the number of compressors or heating stages running.\u003c\/p\u003e\n\n\u003ch3\u003eHeating a large space in 575 V\u003c\/h3\u003e\n\u003cp\u003eThe heat pump delivers 84,000 BTU\/h at 47 °F and 49,000 BTU\/h at 17 °F. To make up the difference, the YORK electrical tables list two electric heat kits in 575 V for this model, of 17 kW and 34 kW, installed in the field. We choose the kit from the heat loss of your building and size the disconnect switch accordingly.\u003c\/p\u003e\n\n\u003ch3\u003eWhat to plan for at installation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof curb:\u003c\/strong\u003e rigid large cabinet curbs of 14 in. (1RC0457) or 24 in. (1RC0459), with an insulated deck. The full perimeter base rail was designed to fit many existing curbs, which we verify on site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifting:\u003c\/strong\u003e 976 lb in operation; the rails have holes for the lifting shackles and for the forks of a forklift.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e plan 48 in. in front of the unit, 36 in. behind (with an economizer), 18 in. on the right, 12 in. on the left and 72 in. clear above.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDucts:\u003c\/strong\u003e supply and return convertible from vertical to horizontal, including in a mixed configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e through-the-base connection kit (1TB0404) to bring in the power without another hole in the roof.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eSimple maintenance, designed for technicians\u003c\/h3\u003e\n\u003cp\u003eThe four 20 x 20 x 2 in. filters are replaced through a tool-less access panel; they ship as MERV 4, and MERV 8 or MERV 13 filters can replace them. The two 22 in. direct-drive condenser fans are fastened to the grille, which speeds up their maintenance. The \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e board watches each circuit, shows the fault codes on its LCD screen and keeps the history, which can be read through its USB port. To go further, a fault detection and diagnostics (FDD) module on the refrigerant side is available as an accessory installed in the field.\u003c\/p\u003e\n\u003cp\u003eOn the reliability side, the board applies the three-trip rule: a pressure switch, the freeze protection or a low voltage must trip three times in two hours before the associated compressor is locked out, which avoids shutdowns for passing alarms. An anti-short-cycle timer, programmable minimum run times and independent fan delays for heating and cooling round out the protection. The cabinet, with its embossed top, receives a powder paint rated at 750 hours of salt spray.\u003c\/p\u003e\n\n\u003ch2\u003eAirGreen, from the estimate to the maintenance of your 7.5 ton unit\u003c\/h2\u003e\n\u003cp\u003eWe start with a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, which covers the space and how it is used, the condition of the ducts, the 575 V distribution and the roof access. We confirm the sizing, organize the lift, install the unit with our own teams and carry out the full commissioning, then we propose planned maintenance suited to your building.\u003c\/p\u003e\n\u003cp\u003eWhether your warehouse, your workshop or your reception hall is in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, our HVAC technicians respond quickly and efficiently. Call us at 514 316-2973 or use the form on airgreen.ca to schedule your visit.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367218852132,"sku":"XXE08A5B3AA1B111A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_6_A_10_TONNES_00_PRINCIPALE_881316c7-31e8-4bd6-9b3a-14d9b3cd9fb2.png?v=1790086820"},{"product_id":"thermopompe-monobloc-york-xxe-de-10-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XXE 10 Ton 575V | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eGym, big-box store or multipurpose hall: 10 tons for very large volumes\u003c\/h2\u003e\n\u003cp\u003eA gym packed on a tournament night, a big-box store with endless aisles, a multipurpose hall that hosts in turn a banquet, an assembly and a sports activity: these spaces call for a lot of air, well distributed, and a reliable installation from the first to the last day of the season. The 10 ton YORK Sun Core XXE packaged heat pump, supplied at \u003cstrong\u003e575 V three-phase\u003c\/strong\u003e, moves a nominal airflow of \u003cstrong\u003e3,600 CFM\u003c\/strong\u003e and splits its capacity between \u003cstrong\u003etwo independent refrigerant circuits\u003c\/strong\u003e. AirGreen sizes it, installs it and maintains it for owners and property managers in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eTwo independent circuits, a safeguard for large volumes\u003c\/h3\u003e\n\u003cp\u003eEach of the two scroll compressors feeds its own refrigerant circuit, with its filter drier on the liquid line and its high and low pressure switches. The control board watches each safety device separately. If one of them trips three times in less than two hours, only the associated compressor is locked out and a fault message appears. For a gym or a hall where an event is planned, this architecture limits the effect of an isolated fault on the installation as a whole.\u003c\/p\u003e\n\u003cp\u003eThe two compressors also form two stages of cooling, at 50% and at 100% of the capacity. The \u003cstrong\u003eEER of 11.0\u003c\/strong\u003e describes the efficiency at full load, while the IEER of 14.6, obtained with the IntelliSpeed drive, takes part-load operation into account. Like the other units of 6 tons and more, this model is not rated in SEER.\u003c\/p\u003e\n\n\u003ch3\u003e3,600 CFM to distribute: high static pressure and IntelliSpeed\u003c\/h3\u003e\n\u003cp\u003eIn a very large volume, the ducts are often long and the grilles many. This model is fitted with the \u003cstrong\u003ehigh static pressure\u003c\/strong\u003e belt-drive indoor fan option, reserved for the three-phase models, with a motor of 5.25 BHP at most according to the guide. The IntelliSpeed drive varies the speed of the supply fan according to the number of compressors or heating stages running. The dry bulb economizer, with its AMCA 511 class 1A low-leakage dampers, can bring in up to 100% outdoor air, and the Smart Equipment control accepts a CO2 sensor in the space for ventilation based on occupancy, an advantage when the attendance of a hall swings widely.\u003c\/p\u003e\n\n\u003ch3\u003eThe packaged principle, at the scale of large volumes\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e brings together in a single outdoor cabinet the compressors, the coils, the fans and the control. Installed on the roof or on a pad, it connects to the supply and return ducts, cools in summer and heats by heat pump the rest of the year. In a room with a high ceiling, it leaves the indoor space completely free. The unit uses \u003cstrong\u003eR-410A\u003c\/strong\u003e, the previous-generation refrigerant: a proven technology, with two separate charges, one per circuit.\u003c\/p\u003e\n\u003cp\u003eOn the construction side, the unit is assembled in Norman, Oklahoma, goes through a fully automated run test on the assembly line and arrives configured and commissioned at the factory. Its embossed top stiffens the cabinet, its powder paint is rated at 750 hours of salt spray, and YORK tests and rates it for cooling up to an outdoor temperature of 125 °F (52 °C).\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eData\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e10 tons (120,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e115,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e114,000 BTU\/h, COP of 3.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e62,000 BTU\/h, COP of 2.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003eEER of 11.0, IEER of 14.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e3,600 CFM (ft³\/min)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e575 V, three-phase, 60 Hz (540 to 630 V applied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressors\u003c\/td\u003e\n\u003ctd\u003e2 scroll, independent circuits, 50% \/ 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (width x length x height)\u003c\/td\u003e\n\u003ctd\u003e61.7 x 87.2 x 48.6 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e1,060 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor sound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e86 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eThe XXE12A5C3AA1B111A3 configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBelt-drive indoor fan, high static pressure option.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e on the supply fan.\u003c\/li\u003e\n\u003cli\u003eFactory-installed dry bulb economizer.\u003c\/li\u003e\n\u003cli\u003eSmart Equipment control and factory-installed supply, return and outdoor air sensors.\u003c\/li\u003e\n\u003cli\u003eStandard coils: three-row condenser of 25.6 ft², four-row evaporator of 11.1 ft², thermostatic expansion valves (TXV).\u003c\/li\u003e\n\u003cli\u003eNo disconnect switch, no convenience receptacle and no factory electric heat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHeating a very large volume\u003c\/h3\u003e\n\u003cp\u003eIn heating mode, the heat pump delivers 114,000 BTU\/h at 47 °F and 62,000 BTU\/h at 17 °F. For the colder days, the YORK electrical tables list two electric heat kits in 575 V for this model, of 17 kW and 34 kW, installed in the field. We select the kit from the actual heat loss of the building and plan the matching disconnect switch.\u003c\/p\u003e\n\n\u003ch3\u003ePlanning the installation of a 1,060 lb unit\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifting:\u003c\/strong\u003e base rails around the full perimeter, with holes for the lifting shackles and for the forks of a forklift.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof curb:\u003c\/strong\u003e rigid large cabinet curbs of 14 in. (1RC0457) or 24 in. (1RC0459); the base rail also fits many existing curbs, which we confirm on site.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 72 in. above, 48 in. at the front, 36 in. at the back since the economizer is installed, 18 in. on the right side and 12 in. on the left side.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSound:\u003c\/strong\u003e with a rating of 86 dBA, we position the unit with the neighbouring windows and buildings in mind.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical:\u003c\/strong\u003e disconnect switch in the field and through-the-base connection kit (1TB0404) to avoid another hole in the roof.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSecurity:\u003c\/strong\u003e burglar bars (1BD0410) and smoke detectors for the supply or return air available as accessories.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eQuick maintenance in spite of the size\u003c\/h3\u003e\n\u003cp\u003eThe condenser is cooled by a single 30 in. direct-drive fan, fastened to the grille for quick maintenance. The four 20 x 20 x 2 in. filters, shipped as MERV 4, are replaced without tools by MERV 8 or MERV 13 if needed. The LCD screen of the Smart Equipment board and its USB port give access to the fault codes, the history and the start-up reports, and a fault detection and diagnostics (FDD) module on the refrigerant side is available as an accessory.\u003c\/p\u003e\n\n\u003ch2\u003eTrust your very large volumes to AirGreen\u003c\/h2\u003e\n\u003cp\u003eA 10 ton unit is chosen from measurements, not from a remote estimate. During the \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, we survey the volume, the maximum occupancy, the duct system, the 575 V distribution and the access for the crane. Our teams install the unit, balance the 3,600 CFM, set up the economizer, the drive and the control, then take care of the planned maintenance.\u003c\/p\u003e\n\u003cp\u003eGyms, big-box stores and multipurpose halls in Montreal, Laval, Longueuil, on the North Shore and on the South Shore: our HVAC teams respond quickly and efficiently. Call us at 514 316-2973 or fill out the form on airgreen.ca to schedule your visit.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367219212580,"sku":"XXE12A5C3AA1B111A3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_6_A_10_TONNES_00_PRINCIPALE_de7a9651-05ee-4f07-b1f1-7ad635e94100.png?v=1790086821"},{"product_id":"thermopompe-monobloc-york-wqe-de-5-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WQE 5 Ton 575V | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eFor 575 V buildings moving to R-454B\u003c\/h2\u003e\n\u003cp\u003eWarehouse, shop, distribution centre or commercial building: when the electrical service is 575 V three-phase, the rooftop unit has to be built for that voltage. This 5-ton YORK Sun Core \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e (60,000 BTU\/h nominal), model WQE06A5C1AA5G111A1, answers that with R-454B and three factory-mounted options: a dry-bulb economizer, a belt-driven high static pressure blower and a refrigerant detection system (RDS). AirGreen sells and installs it in the commercial and industrial buildings of Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003cp\u003eIn the Sun Core line, the WQE is the standard-efficiency unit, below the high-efficiency WYE. Its \u003cstrong\u003eR-454B\u003c\/strong\u003e is an A2L refrigerant with a low global warming potential; the electric backup heat is installed on site.\u003c\/p\u003e\n\u003ch3\u003eWhat the model number tells you\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ecode 5 (voltage): 575 V, three-phase, 60 Hz;\u003c\/li\u003e\n\u003cli\u003ecode C (airflow): high static pressure, belt drive, an option reserved for three-phase models;\u003c\/li\u003e\n\u003cli\u003ecode 5 (sensors): factory-installed RDS;\u003c\/li\u003e\n\u003cli\u003ecode G (economizer): dry bulb, the \"enhanced static\" version;\u003c\/li\u003e\n\u003cli\u003ecode A (control): Smart Equipment, with a thermostat or a zone sensor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe BACnet MS\/TP, Modbus and N2 card (code B) is not included: if your building has a central management system, we confirm this point before ordering.\u003c\/p\u003e\n\u003ch3\u003eThe dry-bulb economizer, mounted and wired at the factory\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eeconomizer\u003c\/strong\u003e uses outdoor air to cool the rooms as soon as the outdoor temperature is below the set point of its module: that is the principle of dry-bulb control, useful when the lighting, the machines and the occupants warm the space in cool weather.\u003c\/p\u003e\n\u003cp\u003eThis downflow module, with barometric relief, arrives installed and wired; all that is left is to assemble the outdoor air hood supplied and fasten it to the unit. Its opposed galvanized steel blades, gear-driven, and its spring-return modulating actuators let it take in up to 100% outdoor air, even while the compressor is running. Its Class 1A low-leakage dampers, licensed to AMCA 511, reach a leakage rate of 3 CFM per square foot at 1 in. of static pressure.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e control integrates it, accepts a CO₂ sensor and is ready for demand-controlled ventilation. A 575 V powered exhaust (kit 2PE04704258) can be added to it; it starts when the dampers pass an adjustable opening threshold.\u003c\/p\u003e\n\u003ch3\u003eA belt-drive blower for demanding duct systems\u003c\/h3\u003e\n\u003cp\u003eLong \u003cstrong\u003educts\u003c\/strong\u003e, filters with a higher MERV rating, an economizer: each element adds resistance to the air path. The high static pressure option on the WQE06 answers that with a 2.9 HP three-phase motor, an adjustable 1VL44 drive pulley and an 11 x 10 in. centrifugal blower.\u003c\/p\u003e\n\u003cp\u003eIts speed range runs from 1,167 to 1,593 rpm, against 792 to 1,208 rpm for the medium static pressure option. With a bottom connection, the YORK tables give 1,253 rpm for 1,500 CFM at an available external static pressure of 1.6 in. of water column, a speed out of reach for the medium option. YORK asks that the resistance of the economizer and, where applicable, of the heat kit be subtracted from it: so we measure the real pressure of your ducts before setting the pulley.\u003c\/p\u003e\n\u003ch3\u003eA single outdoor cabinet, watched over by the RDS\u003c\/h3\u003e\n\u003cp\u003eA packaged heat pump brings together the scroll compressor, copper and aluminum coils, blower, filters, control and economizer in one outdoor cabinet, set on the roof or at grade and tied into the ducts. Assembled at the factory, where every unit is configured and run-tested, the R-454B circuit stays outside the occupied rooms, inside that cabinet.\u003c\/p\u003e\n\u003cp\u003eR-454B belongs to Class A2L, that of the refrigerants with low toxicity and low flammability. The built-in sensors of the \u003cstrong\u003erefrigerant detection system\u003c\/strong\u003e are placed to detect a leak in the cabinet accurately and quickly. Tied to the control, the RDS automatically starts a refrigerant dilution sequence and raises an alarm as soon as the concentration reaches 25% of the lower flammability limit. No detection kit has to be added.\u003c\/p\u003e\n\u003ch3\u003eSpecifications of this configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated capacity: 5 tons (60,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eNet AHRI cooling: 57,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 53,000 BTU\/h, COP of 3.5\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 29,000 BTU\/h, COP of 2.15\u003c\/li\u003e\n\u003cli\u003eEfficiency: 14.0 SEER2, 6.7 HSPF2 and 11.8 EER2\u003c\/li\u003e\n\u003cli\u003eRated airflow: 1,550 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 575 V three-phase, 60 Hz (applied voltage from 540 to 630 V)\u003c\/li\u003e\n\u003cli\u003eDimensions (width, length, height): 48.9 x 74.1 x 40.6 in.\u003c\/li\u003e\n\u003cli\u003eWeight: 627 lb in operation, 640 lb shipping\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270): 77.8 dBA\u003c\/li\u003e\n\u003cli\u003eFilters: four of 16 x 16 x 2 in., MERV 4 as supplied\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eR-454B or R-410A: the comparison with the 575 V XQE06\u003c\/h3\u003e\n\u003cp\u003eWe also offer the XQE06 on R-410A in 575 V: the same 48.9 x 74.1 x 40.6 in. cabinet, the same 627 lb weight and the same 77.8 dBA sound rating.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFigure\u003c\/th\u003e\n\u003cth\u003eWQE06 (R-454B)\u003c\/th\u003e\n\u003cth\u003eXQE06 (R-410A)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet cooling\u003c\/td\u003e\n\u003ctd\u003e57,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e57,400 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e53,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e54,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e29,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e30,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2, HSPF2 and EER2\u003c\/td\u003e\n\u003ctd\u003e14.0, 6.7 and 11.8\u003c\/td\u003e\n\u003ctd\u003e13.4, 6.7 and 11.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe XQE06 delivers a little more capacity; the WQE06 gets the better SEER2, with an equal HSPF2 and an almost equal EER2. R-410A is a previous-generation refrigerant with proven technology; on the WQE06, the R-454B is watched by a factory-installed RDS. We compare the two with you.\u003c\/p\u003e\n\u003ch3\u003e575 V electrical work and backup heat\u003c\/h3\u003e\n\u003cp\u003eTwo \u003cstrong\u003eelectric heat\u003c\/strong\u003e kits are installed on site in 575 V: 13.8 kW (2EK04511458) and 23 kW (2EK04512358), hardware and connectors included. Here are the YORK values for this high static pressure blower configuration, with no powered convenience outlet (MCA: minimum circuit ampacity).\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eBackup heat\u003c\/th\u003e\n\u003cth\u003eMCA\u003c\/th\u003e\n\u003cth\u003eMaximum fuse or breaker\u003c\/th\u003e\n\u003cth\u003eMCA with powered exhaust\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003ctd\u003e10.2 A\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003ctd\u003e10.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e13.8 kW kit\u003c\/td\u003e\n\u003ctd\u003e26.8 A\u003c\/td\u003e\n\u003ctd\u003e30 A\u003c\/td\u003e\n\u003ctd\u003e27.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e23 kW kit\u003c\/td\u003e\n\u003ctd\u003e37.8 A\u003c\/td\u003e\n\u003ctd\u003e40 A\u003c\/td\u003e\n\u003ctd\u003e38.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe maximum rating (dual-element time-delay fuse or HACR-type breaker) stays the same with the exhaust. With no factory disconnect, we install an external disconnect sized from the nameplate. The through-the-base electrical entry kit (1TB0403) avoids a new roof penetration.\u003c\/p\u003e\n\u003ch3\u003ePreparing the roof and the site\u003c\/h3\u003e\n\u003cp\u003eSince the factory economizer is downflow, the return air connects from below, ideally on a 14 or 24 in. YORK roof curb (1RC0456 or 1RC0458), with insulated decks, where the ducts are fastened before the unit is set in place.\u003c\/p\u003e\n\u003cp\u003eWith an economizer, YORK requires 36 in. of clearance at the back and prohibits any discharge of combustion products within 10 ft. of that back: so we locate chimneys and vents before settling the location, then plan the crane around the unit's 640 lb shipping weight.\u003c\/p\u003e\n\u003ch2\u003eAirGreen, from the 575 V check to commissioning\u003c\/h2\u003e\n\u003cp\u003eA 575 V project calls for coordinating the electrical work, the roofing and the ducts. Our teams handle it end to end: free on-site estimate, load calculation and sizing, installation, setting of the pulley and of the economizer, commissioning, then maintenance of the belt, the filters, the dampers and the RDS. As a Montreal \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor, we count on fast, efficient visits, planned to limit the interruption of your operations.\u003c\/p\u003e\n\u003cp\u003eFor a building in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, call 514 316-2973 or fill out the form on airgreen.ca: we will schedule your free on-site estimate quickly.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367627829540,"sku":"WQE06A5C1AA5G111A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_08482e30-381e-44a9-b68a-1f5b4d32fd9a.png?v=1790086822"},{"product_id":"thermopompe-monobloc-york-xqe-de-3-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XQE 3 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eStore or office on 208\/230 V three-phase: 3 tons on R-410A in a 32.5 in. cabinet\u003c\/h2\u003e\n\u003cp\u003eIf your store or your office needs about 3 tons of cooling, if the electrical service is 208\/230 V three-phase and you prefer to stay on R-410A, the 3 ton YORK Sun Core XQE answers that profile. This \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e of 36,000 BTU\/h nominal, rated 13.4 SEER2, sits in the short 32.5 in. cabinet and comes with a belt-driven medium static pressure blower. At AirGreen, an \u003cstrong\u003eHVAC\u003c\/strong\u003e contractor, we sell and install it in Montreal as well as in Laval and Longueuil, on the North Shore as on the South Shore.\u003c\/p\u003e\n\u003cp\u003eThe factory configuration of the XQE04A2B1AA1A111A2 model stays simple: Smart Equipment control, standard coils, no economizer, no disconnect switch and no built-in heat. In the field we add only what your space requires.\u003c\/p\u003e\n\u003ch3\u003eThe whole system outdoors, nothing on the sales floor\u003c\/h3\u003e\n\u003cp\u003eCompressor, coils, fans, filters and control share a single outdoor cabinet, installed on the roof or at ground level, then tied into the \u003cstrong\u003educt\u003c\/strong\u003e system. In summer, the unit cools; in winter, it heats in heat pump mode, with backup heat from an electric kit added in the field. Nothing encroaches on the sales floor or on the drop ceiling, and maintenance is done outside, without disturbing your customers.\u003c\/p\u003e\n\u003ch3\u003eCapacities, ratings and size at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAHRI net cooling:\u003c\/strong\u003e 35,600 BTU\/h\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating at 47 °F (8.3 °C):\u003c\/strong\u003e 34,200 BTU\/h, COP of 3.25\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeating at 17 °F (-8.3 °C):\u003c\/strong\u003e 18,500 BTU\/h, COP of 2.12\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2 standard:\u003c\/strong\u003e 13.4 SEER2, 6.7 HSPF2 and 12.0 EER2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePrevious standard:\u003c\/strong\u003e 14.0 SEER and 8.1 HSPF\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal airflow:\u003c\/strong\u003e 1,238 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e 208\/230 V, three-phase, 60 Hz (allowable voltage from 187 to 252 V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth x depth x height:\u003c\/strong\u003e 48.9 x 74.1 x 32.5 in.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 529 lb operating, 542 lb shipping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutdoor sound level (AHRI 270):\u003c\/strong\u003e 78.4 dBA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilters:\u003c\/strong\u003e two 16 x 25 x 2 in. disposable filters (MERV 4 as delivered)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAccessories specific to the 32.5 in. cabinet\u003c\/h3\u003e\n\u003cp\u003eOn the same footprint, the 4 and 5 ton XQE reach 40.6 in. in height; the 3 ton version stops at 32.5 in., the lowest cabinet of this size. Behind a low parapet, it stays more discreet. This short cabinet has its own accessories:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHail guard 1HG0419:\u003c\/strong\u003e a louvred panel set in front of the outdoor coil to protect its fins from hail.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHorizontal flow economizer 2EE04707024:\u003c\/strong\u003e for ducts connected from the side, since the unit can be converted in the field to a horizontal connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHinged panel 1HD0401 for filter access:\u003c\/strong\u003e the companion to that economizer.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eBelt-driven blower: the margin it gives your ducts\u003c\/h3\u003e\n\u003cp\u003eOn the 3 to 5 ton XQE, the base option is a direct-drive blower. The B in the eighth position of the model number stands instead for the \u003cstrong\u003emedium static pressure\u003c\/strong\u003e option: a double-inlet centrifugal wheel, belted to a 2.4 HP three-phase motor. Set by its variable-pitch drive pulley (1VL34), the blower speed runs from 792 to 1,208 rpm.\u003c\/p\u003e\n\u003cp\u003eAccording to the YORK tables, moving 1,200 CFM against 1.0 in. w.c. of external static pressure, in bottom connection, takes 1,191 rpm, which this option delivers. At the same pressure, the base direct-drive blower tops out at 872 CFM. In an office with long, elbowed ducts, that reserve helps hold the intended airflow; at start-up, we measure the pressure and set the pulley accordingly.\u003c\/p\u003e\n\u003ch3\u003eSmart Equipment in stand-alone mode and proven mechanics\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSmart Equipment\u003c\/strong\u003e is supplied here without a communication card, which suits a space with no building management system. A 24 V thermostat or a zone sensor is enough to drive it, and its three air sensors are already fitted at the factory. A CO2 sensor can also be connected to it: combined with an economizer, it adjusts the fresh air intake to occupancy. Its low ambient function lets the unit cool even when it is only 40 °F (4.4 °C) outside, an advantage in spring, when computers and lighting warm up the offices.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003escroll compressor\u003c\/strong\u003e is mounted on rubber grommets and internally protected against overheating and overcurrent. The coils pair internally grooved copper tubes with aluminum fins, and the blower compartment is insulated with 1\/2 in. fibreglass.\u003c\/p\u003e\n\u003ch3\u003eSame cabinet, two refrigerants: R-410A or R-454B\u003c\/h3\u003e\n\u003cp\u003eHere are the two versions of this 3 ton format:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eData\u003c\/th\u003e\n\u003cth\u003eXQE04 (R-410A)\u003c\/th\u003e\n\u003cth\u003eWQE04 (R-454B)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e35,600 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e35,600 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e18,500 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e19,500 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2 \/ HSPF2 \/ EER2\u003c\/td\u003e\n\u003ctd\u003e13.4 \/ 6.7 \/ 12.0\u003c\/td\u003e\n\u003ctd\u003e14.0 \/ 6.7 \/ 12.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions and weight\u003c\/td\u003e\n\u003ctd\u003e48.9 x 74.1 x 32.5 in., 529 lb\u003c\/td\u003e\n\u003ctd\u003eIdentical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlower on the version offered\u003c\/td\u003e\n\u003ctd\u003eMedium static pressure\u003c\/td\u003e\n\u003ctd\u003eHigh static pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eThe WQE04 posts a slightly higher SEER2 and EER2 and heats a little more at 17 °F; it uses R-454B, an A2L refrigerant with a low global warming potential, and the version offered includes a refrigerant detection system (RDS). The XQE04 stays on R-410A, a proven technology from the previous generation, and its rating under the previous standard makes the comparison with an older unit easier. If your other equipment runs on R-410A, the XQE04 is the obvious choice; if the climate impact of the refrigerant comes first, we will propose the WQE04.\u003c\/p\u003e\n\u003ch3\u003eThe three-phase electrical service and the heat kits\u003c\/h3\u003e\n\u003cp\u003eFor this configuration with no electric backup, the YORK guide gives an MCA (\u003cstrong\u003eminimum circuit ampacity\u003c\/strong\u003e) of 20.2 A at 208 V and 20.5 A at 230 V; the maximum protection is 30 A (time-delay fuse or HACR breaker). Three heat kits are installed in the field:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e2EK04510625: 6.5 kW at 230 V (4.9 kW at 208 V)\u003c\/li\u003e\n\u003cli\u003e2EK04511125: 10.5 kW at 230 V (7.9 kW at 208 V)\u003c\/li\u003e\n\u003cli\u003e2EK04511625: 16 kW at 230 V (12 kW at 208 V)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 16 kW kit brings the MCA to 68.6 A at 230 V and the maximum protection to 70 A: we therefore check your panel first. The unit arrives without a factory disconnect switch; we install one, sized from the nameplate, and a bottom power entry kit brings the supply in without piercing the membrane anywhere else.\u003c\/p\u003e\n\u003ch3\u003eBefore installation on a commercial roof\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSurvey the existing curb or plan a new 14 or 24 in. YORK curb, to which the ducts can be connected before the unit arrives.\u003c\/li\u003e\n\u003cli\u003eCheck the roof structure: the guide gives 127 to 137 lb at each corner of the unit.\u003c\/li\u003e\n\u003cli\u003eClear the space around the unit: 36 in. in front, 18 in. behind (36 in. with an economizer or a powered exhaust), 12 in. on the left, 18 in. on the right and 72 in. above for the air discharge.\u003c\/li\u003e\n\u003cli\u003ePlan the crane lift: the lifting shackles hook directly to the unit's base rails.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eAirGreen takes care of your 3 ton unit, from the survey to the maintenance\u003c\/h2\u003e\n\u003cp\u003eDuring the \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, we measure what drives the sizing: the actual load of the space, the static pressure of the ducts, the electrical service and the roof curb. We then recommend the XQE04 or the WQE04, with the right heat kit. We arrange the crane, connect the unit, balance the airflow and carry out the commissioning; our technicians come back through the seasons for the maintenance: filters, coils, belt and pulley.\u003c\/p\u003e\n\u003cp\u003eWe work in Montreal, Laval and Longueuil, as well as on the North Shore and the South Shore. To set up your free on-site estimate, a call to 514 316-2973 or a request through the form on airgreen.ca is all it takes: we will offer you a visit date without delay.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367633858852,"sku":"XQE04A2B1AA1A111A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_1948b118-e48d-4895-bc47-1e9c763479a1.png?v=1790086978"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/collections\/THERMOPOMPE_MONOBLOC_YORK_SUN_CORE_3_A_5_TONNES_00_PRINCIPALE_5a3515be-5bc4-4bfd-ab0f-17ece8154ebb.png?v=1790171267","url":"https:\/\/airgreen.ca\/en\/collections\/thermopompe-monobloc-york-sun-core-montreal-laval-longueuil-rive-sud-nord.oembed","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}