{"title":"Thermopompe Monobloc YORK Sun Pro WP et XP | Montréal, Laval, Longueuil, Rive Sud \u0026 Nord","description":null,"products":[{"product_id":"thermopompe-monobloc-york-xp-de-7-5-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XP 7.5 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eA mid-size business deserves cooling that follows its traffic\u003c\/h2\u003e\n\u003cp\u003eA store that fills up on Saturday, a dining room that goes from a quiet afternoon to the rush of dinner service, offices that empty out at the end of the day: the thermal load of a business changes from hour to hour. This packaged heat pump from the YORK Sun Pro series answers that reality with \u003cstrong\u003etwo scroll compressors\u003c\/strong\u003e and two stages of cooling, on the \u003cstrong\u003e208\/230 V three-phase\u003c\/strong\u003e supply found in a good number of commercial spaces. At AirGreen, we supply it, install it and maintain it for merchants, owners and building managers in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eThe whole system in a single cabinet, on the roof\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e brings the compressors, the coils, the fans and the controls together in a single outdoor cabinet. Set on a roof curb, on a pad or on a structure, it connects directly to the building's supply and return ducts. For a business, the gain is concrete: no indoor unit takes up sales or storage space, and our technicians work on the roof without disturbing your customers. The same machine cools in summer and heats by heat pump the rest of the year, with the option of adding electric backup heat.\u003c\/p\u003e\n\u003cp\u003eEvery Sun Pro unit leaves the factory charged with refrigerant, wired, piped and tested. It runs on \u003cstrong\u003eR-410A\u003c\/strong\u003e, the previous-generation refrigerant: a proven technology that refrigeration technicians know well.\u003c\/p\u003e\n\n\u003ch3\u003eTwo compressors, two stages, efficiency measured at part load\u003c\/h3\u003e\n\u003cp\u003eThe two scroll compressors feed two independent refrigeration circuits, with steps at 50% and 100% of capacity. On a mild day, one compressor can be enough; the second comes in when the sun hits the storefront or the space fills up. This staging limits on-off cycling and helps hold a steady temperature for your customers and your staff. A compressor swap function (lead-lag), selectable on the control board, can also even out their running hours.\u003c\/p\u003e\n\u003cp\u003eThe efficiency ratings reflect that behaviour. The \u003cstrong\u003e11.2 EER\u003c\/strong\u003e measures full-load performance, while the \u003cstrong\u003e14.6 IEER\u003c\/strong\u003e, obtained with the IntelliSpeed drive, takes part-load operation into account and gives a better picture of a real season of use. Like every unit of 6 tons and up, this model is rated in EER and IEER, not in SEER.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications of the model\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated capacity: 7.5 tons (90,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 92,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 87,000 BTU\/h, COP of 3.5\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 51,000 BTU\/h, COP of 2.25\u003c\/li\u003e\n\u003cli\u003eEfficiency: 11.2 EER and 14.6 IEER\u003c\/li\u003e\n\u003cli\u003eRated airflow: 3,000 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V, three-phase, 60 Hz\u003c\/li\u003e\n\u003cli\u003eCompressors: 2 scroll, steps at 50% and 100%\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-410A, thermostatic expansion valves (TXV)\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 59 x 89 x 50.75 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 1,090 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270): 83 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe factory configuration of this model\u003c\/h3\u003e\n\u003cp\u003eThe number XP090C00R2B1BAA1A2 reads option by option in the YORK nomenclature. Here is what it includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e with high static pressure drive package (3 HP motor): the supply fan speed varies with the number of compressors or heating stages running, and the minimum economizer position is set according to the drive frequency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEconomizer\u003c\/strong\u003e with barometric relief damper, to take advantage of cool outdoor air in the shoulder seasons.\u003c\/li\u003e\n\u003cli\u003ePhase monitor, which protects the unit against phase loss and reverse rotation.\u003c\/li\u003e\n\u003cli\u003eStand-alone Smart Equipment control, compatible with a thermostat or a zone sensor.\u003c\/li\u003e\n\u003cli\u003eStandard coils, without E-Coat coating.\u003c\/li\u003e\n\u003cli\u003eNo factory service option: no disconnect switch and no convenience outlet, the disconnect is planned for in the field.\u003c\/li\u003e\n\u003cli\u003eDisposable 2 in. filters, standard cabinet and no factory-installed electric heat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe Sun Pro strengths that simplify day-to-day management\u003c\/h3\u003e\n\u003ch4\u003eFast, tool-free maintenance\u003c\/h4\u003e\n\u003cp\u003eTool-free hinged panels give access to the control box, the compressors, the filters, the motor and the indoor blower. The non-corrosive condensate pan slides out the back of the unit for cleaning, and service windows cut into both condenser walls make coil inspection easier. The motor-and-blower assembly slides out, and a second nameplate, placed inside the control door, stays legible despite the weather.\u003c\/p\u003e\n\u003ch4\u003eA control that reports clearly\u003c\/h4\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e board has an LCD screen and a navigation joystick: unit status, supply, return and outdoor temperatures, fault codes. Its USB port lets you review the fault history, run software updates and pull the self-test and start-up reports. The air sensors are factory-installed, the supply voltage is monitored for brownouts, and an anti-short-cycle delay protects the compressors. If a safety device trips three times in two hours, only the associated compressor is locked out, and a message is displayed.\u003c\/p\u003e\n\u003ch4\u003eA build designed for the roof\u003c\/h4\u003e\n\u003cp\u003eFreeze thermostats on the suction line, solid-core filter driers, high and low pressure switches and crankcase heaters are standard equipment. The galvanized steel cabinet gets a powder paint proven by a 750-hour salt spray test. The built-in low-ambient control allows cooling down to 0 °F (-17.8 °C) outdoors with no additional component, useful for spaces that give off heat even in winter.\u003c\/p\u003e\n\n\u003ch3\u003eGetting the 208\/230 V three-phase installation right\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower supply:\u003c\/strong\u003e the YORK guide calls for an applied voltage of 187 to 252 V. We check the three-phase service and the panel capacity, especially if backup heat is planned.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric heat:\u003c\/strong\u003e for this size, YORK offers 9, 18, 24 or 36 kW kits, designed for a single-point power connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof curb:\u003c\/strong\u003e available in 8 in. or 14 in., with an insulated deck. The roof curb is common to the whole Sun Pro series from 6.5 to 12.5 tons, and a 10 in. transition curb makes it possible to reuse the footprint of an older Sunline unit from 7.5 to 12.5 tons.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifting:\u003c\/strong\u003e the full-perimeter base rails have lifting holes for the crane and fork slots on three sides.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 72 in. above, 36 in. at the front, at the back and on the left, 12 in. on the right.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDucts:\u003c\/strong\u003e bottom or side connection; the conversion is done by moving the factory covers, with no panel cutting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eAirGreen supports your Sun Pro project, from the estimate to the maintenance\u003c\/h2\u003e\n\u003cp\u003eIt all starts with a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e. We take down the floor area, the occupancy, the condition of the ducts, the electrical service and the roof access, then we confirm that 7.5 tons really is the right match for your space rather than a neighbouring size in the series. Our teams coordinate the lift, install the unit, connect the ducts and carry out the start-up: economizer setting, IntelliSpeed parameters and Smart Equipment control configuration. We then offer planned maintenance: filters, coils, belt, condensate pan and a reading of the fault history.\u003c\/p\u003e\n\u003cp\u003eAs an HVAC contractor, we serve businesses in Montreal, Laval, Longueuil, the North Shore and the South Shore with fast and efficient service calls. To schedule your visit, call us at 514 316-2973 or fill out the form on airgreen.ca: we will get back to you quickly with a clear quote.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367217377572,"sku":"XP090C00R2B1BAA1A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_PRO_00_PRINCIPALE_dc6a782e-8cf1-42c3-b40e-23a8c65172f8.png?v=1790086722"},{"product_id":"thermopompe-monobloc-york-xp-de-7-5-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XP 7.5 Ton 575V | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eThe 7.5 ton Sun Pro capacity, connected to the 575 V network of your industrial building\u003c\/h2\u003e\n\u003cp\u003eIn a factory, a warehouse or a shop supplied at 575 V, cooling the offices, the break room or a light production area should not call for a step-down transformer. This YORK Sun Pro packaged heat pump delivers exactly the same capacity as the 208\/230 V version, but it is built for \u003cstrong\u003e575 V three-phase\u003c\/strong\u003e. Our teams take care of the lift, the \u003cstrong\u003ecommissioning\u003c\/strong\u003e and the maintenance, so your maintenance staff does not have to get to know a new unit on their own. We work in industrial buildings in Montreal, Laval, Longueuil, on the North Shore and on the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the 575 V version changes\u003c\/h3\u003e\n\u003cp\u003eThe YORK guide allows an applied voltage from 540 to 630 V for this version. The connection is made directly on the building's 575 V distribution, and the electrical accessories follow the same voltage: the electric heat kits of 9, 18, 24 and 36 kW and the powered exhaust fan are available in 575 V. Performance, for its part, stays identical to that of the 208\/230 V model: same net cooling, same EER and IEER ratings, same airflow.\u003c\/p\u003e\n\u003cp\u003eOne point deserves your attention: this unit is meant for human comfort. For a process application, such as a server room or an electrical room, YORK recommends consulting its applications department. We take that step for you when your project comes close to it.\u003c\/p\u003e\n\n\u003ch3\u003eA single cabinet on the roof, the plant floor stays clear\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e brings together in one outdoor cabinet everything a split system spreads between the indoor and the outdoor side: compressors, coils, fans and control. Installed on a roof curb, a pad or a steel structure, it feeds the ducts that serve your offices or your work area, and it provides both cooling and heat pump heating. No equipment clutters the production floor, and all the work is done outside.\u003c\/p\u003e\n\u003cp\u003eThe unit arrives charged with \u003cstrong\u003eR-410A\u003c\/strong\u003e, wired, piped and factory tested. This previous-generation refrigerant is a proven technology, well known to refrigeration technicians.\u003c\/p\u003e\n\n\u003ch3\u003eThe performance data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal capacity\u003c\/td\u003e\n\u003ctd\u003e7.5 tons (90,000 BTU\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e92,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e87,000 BTU\/h, COP of 3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e51,000 BTU\/h, COP of 2.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER \/ IEER\u003c\/td\u003e\n\u003ctd\u003e11.2 \/ 14.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e3,000 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e575 V, three-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressors\u003c\/td\u003e\n\u003ctd\u003e2 scroll, two stages (50% \/ 100%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (width x length x height)\u003c\/td\u003e\n\u003ctd\u003e59 x 89 x 50.75 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e1,090 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor sound level (AHRI 270)\u003c\/td\u003e\n\u003ctd\u003e83 dBA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eThe configuration as delivered\u003c\/h3\u003e\n\u003cp\u003eThe XP090C00R5B1BAA1A2 model includes an \u003cstrong\u003eIntelliSpeed variable-speed drive\u003c\/strong\u003e with a high static pressure drive, an economizer with a barometric relief damper, a phase monitor, the stand-alone Smart Equipment control and standard coils. It has no factory service option (no disconnect switch and no convenience receptacle) and no factory-installed electric heat: the disconnect switch and, if needed, the heat kit are added in the field. It ships with 2 in. disposable filters.\u003c\/p\u003e\n\n\u003ch3\u003eA build made for an industrial roof\u003c\/h3\u003e\n\u003cp\u003eBefore leaving the factory, every Sun Pro unit goes through computer-automated tests: refrigerant charge and pressure, electrical current and full operation. The galvanized steel cabinet receives a powder paint that has passed a 750 hour salt spray test, and the full perimeter base rails protect the unit during transport and lifting, with forklift slots on three sides. Aluminum-faced and elastomeric rubber insulation, used throughout the cabinet, supports indoor air quality. Finally, the built-in low-ambient control keeps cooling down to 0 °F (-17.8 °C) outdoors, an advantage when equipment gives off heat in your offices or your control room in the middle of winter.\u003c\/p\u003e\n\n\u003ch3\u003eOur commissioning, step by step\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eCheck of the supply voltage within the 540 to 630 V range and of the phase order, watched by the phase monitor.\u003c\/li\u003e\n\u003cli\u003eCheck of the clearances required by YORK: 72 in. clear above the unit, 36 in. on the front, back and left sides, and 12 in. on the right side.\u003c\/li\u003e\n\u003cli\u003eAdjustment of the belt drive and of the IntelliSpeed speeds to the actual static pressure of your ducts, to deliver the intended airflow.\u003c\/li\u003e\n\u003cli\u003eSetup of the economizer: changeover setpoint for free cooling mode and minimum fresh air position.\u003c\/li\u003e\n\u003cli\u003eProgramming of the Smart Equipment control: thermostat or zone sensor, fan delays, compressor lockout on low outdoor temperature if needed.\u003c\/li\u003e\n\u003cli\u003eExtraction of the start-up report through the USB port and a walkthrough for your maintenance manager.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003ePlanned maintenance suited to an industrial setting\u003c\/h3\u003e\n\u003ch4\u003eFilters and air quality\u003c\/h4\u003e\n\u003cp\u003eThe unit uses four 24 x 20 x 2 in. filters. In a dusty environment, 2 in. MERV 8 or 4 in. MERV 13 pleated filters can replace the disposable filters, and a dirty filter switch is available to signal an abnormal pressure drop.\u003c\/p\u003e\n\u003ch4\u003eCoils, fan and condensate\u003c\/h4\u003e\n\u003cp\u003eService windows in the condenser walls allow the coils to be cleaned without heavy disassembly. The motor and fan assembly slides out of the cabinet, and the non-corrosive condensate pan is pulled out from the back. The hinged panels open without tools, then are screwed shut again after each visit to block access by unauthorized people.\u003c\/p\u003e\n\u003ch4\u003eDiagnostics\u003c\/h4\u003e\n\u003cp\u003eAt every visit, we review the fault history recorded by the Smart Equipment board. Thanks to the two independent refrigerant circuits, a fault on one circuit locks out only the compressor tied to it, after three trips in two hours.\u003c\/p\u003e\n\n\u003ch3\u003eAccessories that earn their place in an industrial setting\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCoil guard and hail guard kit.\u003c\/li\u003e\n\u003cli\u003eSmoke detectors for the supply or return air.\u003c\/li\u003e\n\u003cli\u003eCO2 sensor, which drives the economizer open when the level goes above the preset limit.\u003c\/li\u003e\n\u003cli\u003eBurglar bars for the duct openings of the roof curb.\u003c\/li\u003e\n\u003cli\u003eRoof curb of 8 in. or 14 in., or transition curb for an older Sunline unit of 7.5 to 12.5 tons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eYour industrial project in the hands of our teams\u003c\/h2\u003e\n\u003cp\u003eWe start with a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, which surveys the loads, the condition of the ducts, the 575 V distribution and the access to the roof or to the pad. We confirm the sizing, plan the crane lift using the base rails with their lifting holes, install the unit with our own teams and carry out the commissioning described above. A planned maintenance contract then helps keep the unit reliable, season after season.\u003c\/p\u003e\n\u003cp\u003eAs an HVAC contractor, AirGreen serves the industrial parks and commercial buildings of Montreal, Laval, Longueuil, the North Shore and the South Shore, with fast and efficient service calls. Call us at 514 316-2973 or write to us through the form on airgreen.ca to schedule your visit.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367217410340,"sku":"XP090C00R5B1BAA1A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_PRO_00_PRINCIPALE_e5f8132a-afbd-4131-a438-869be02b7882.png?v=1790086770"},{"product_id":"thermopompe-monobloc-york-xp-de-10-tonnes-575v-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XP 10 Ton 575V | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eTen tons and 3,300 CFM for large commercial and industrial volumes\u003c\/h2\u003e\n\u003cp\u003eA showroom with a high ceiling, an open-plan retail store, a manufacturing shop or a shipping area have one thing in common: a lot of air to move and a load that varies with the hour, the season and the activity. This 10 ton YORK Sun Pro packaged heat pump, supplied at \u003cstrong\u003e575 V three-phase\u003c\/strong\u003e, delivers a nominal airflow of 3,300 CFM and splits its capacity over \u003cstrong\u003etwo stages of cooling\u003c\/strong\u003e. AirGreen sizes it, installs it and maintains it for the buildings of Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eFigures that match large spaces\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal capacity: 10 tons (120,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 111,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 102,000 BTU\/h, COP of 3.5\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 59,000 BTU\/h, COP of 2.25\u003c\/li\u003e\n\u003cli\u003eEER of 11.0 and IEER of 14.5\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 3,300 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 575 V, three-phase, 60 Hz (applied voltage from 540 to 630 V)\u003c\/li\u003e\n\u003cli\u003eTwo scroll compressors on independent circuits, steps of 50% and 100%\u003c\/li\u003e\n\u003cli\u003eR-410A refrigerant\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 59 x 89 x 50.75 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 1,135 lb\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270): 83 dBA\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTwo stages for a large volume that does not fill up all at once\u003c\/h3\u003e\n\u003cp\u003eA large space does not always reach its full load as soon as it opens. In the morning, the first compressor, which on its own provides half the capacity, can be enough; the second starts when foot traffic, lighting and solar gains add up. With the \u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e on this model, the supply fan slows down when only the first stage is running, then speeds up on the second. It is this part-load operation that the IEER of 14.5 measures, while the EER of 11.0 describes the efficiency at full load. Like every unit of 6 tons and more, this model has no SEER rating.\u003c\/p\u003e\n\u003cp\u003eThe two refrigerant circuits are independent and monitored separately by the control board, which follows the state of the high and low pressure switches of each one. A lead-lag option spreads the run hours between the two compressors.\u003c\/p\u003e\n\n\u003ch3\u003eA packaged unit that thinks big without taking up more room\u003c\/h3\u003e\n\u003cp\u003eThe principle remains that of any \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e, with compressors, coils, fans and control brought together in a single outdoor cabinet, connected to the building's ducts. The 10 ton version keeps the same 59 x 89 x 50.75 in. cabinet as the Sun Pro models from 6.5 to 8.5 tons, and the roof curb is common to the whole series. The outdoor coil, with its circuits on separate faces, offers 29 ft² of surface; the indoor coil, with four rows, offers 13.2. Two 24 in. direct-drive condenser fans push the heat upward.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eR-410A\u003c\/strong\u003e, the previous-generation refrigerant, is a proven technology. The unit is delivered charged, wired, piped and factory tested, which shortens the work in the field.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the XP120C00R5B1BAA1A2 model includes\u003c\/h3\u003e\n\u003cp\u003eDecoded from the YORK nomenclature, this number corresponds to the following configuration:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIntelliSpeed variable-speed drive with a high static pressure belt drive (3 HP motor).\u003c\/li\u003e\n\u003cli\u003eEconomizer with a barometric relief damper, able to bring in up to 100% outdoor air.\u003c\/li\u003e\n\u003cli\u003ePhase monitor and stand-alone Smart Equipment control.\u003c\/li\u003e\n\u003cli\u003eStandard coils and 2 in. disposable filters.\u003c\/li\u003e\n\u003cli\u003eNo factory service option and no factory-installed electric heat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eDelivering 3,300 CFM: our design advice\u003c\/h3\u003e\n\u003cp\u003eA high airflow only gives good comfort if the duct system keeps up. The high static pressure drive suits long duct systems or ones loaded with accessories, and the belt is adjusted precisely to the needs of the job. The unit connects from the bottom or from the side; the factory covers simply move over, with no cutting. In a large occupied volume, the economizer with its low-leakage dampers (AMCA 511, class 1A) brings in fresh air and free cooling in the shoulder seasons, and a 575 V powered exhaust fan can be added when the fresh air brought in has to be exhausted. A CO2 sensor can also drive the economizer open when occupancy pushes the level up.\u003c\/p\u003e\n\n\u003ch3\u003eHeating: heat pump first, electric backup heat when needed\u003c\/h3\u003e\n\u003cp\u003eIn heating mode, the heat pump delivers 102,000 BTU\/h at 47 °F and 59,000 BTU\/h at 17 °F. For the colder periods, YORK offers for this model electric heat kits of 18, 24, 36 or 54 kW in 575 V, with nickel-chrome elements, an automatic-reset temperature limit and single point power supply. The heat section slides out of the unit for maintenance. We choose the kit from the actual heat loss of the building and the capacity of your electrical distribution.\u003c\/p\u003e\n\n\u003ch3\u003eControls and protections worthy of the investment\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e board monitors the outdoor, supply and return air temperatures through factory-installed sensors, as well as the supply voltage, in order to protect the unit during a voltage drop. Its LCD screen shows the operating status and the fault codes, and its USB port keeps the fault history, allows software updates and produces the start-up reports. A low limit function keeps the supply air from dropping below a programmable setpoint when cooling is needed in cold weather. On the refrigerant side, freeze thermostats on the suction line, solid core filter driers, pressure switches and crankcase heaters protect the installation. For remote monitoring, a MAP (Mobile Access Portal) gateway is available as an accessory for this control.\u003c\/p\u003e\n\n\u003ch3\u003eLifting and connection\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFull perimeter base rails with lifting holes for the crane and forklift slots on three sides.\u003c\/li\u003e\n\u003cli\u003eRoof curb of 8 in. or 14 in. with an insulated deck, or a 10 in. transition curb to take over the spot of a Sunline unit of 7.5 to 12.5 tons.\u003c\/li\u003e\n\u003cli\u003eMinimum clearances: 12 in. on the right, 36 in. on the left, at the front and at the back, and 72 in. above so that nothing blocks the condenser air discharge.\u003c\/li\u003e\n\u003cli\u003eDisconnect switch to be planned in the field, since this model has no factory service option.\u003c\/li\u003e\n\u003cli\u003eElectrical entry from the side or from underneath, with separate openings for the control wiring.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTrust your 10 ton project to AirGreen\u003c\/h2\u003e\n\u003cp\u003eA unit of this size is chosen with a serious load calculation. During the \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, we measure the volume, note the occupancy, examine the existing ducts and the 575 V distribution, then we check the access for the crane. Our teams install the unit, balance the airflow, set up the economizer, the IntelliSpeed drive and the Smart Equipment control, then take care of the planned maintenance: filters, coils, belt and a read of the fault history.\u003c\/p\u003e\n\u003cp\u003eAs an HVAC contractor, AirGreen responds quickly in Montreal, Laval, Longueuil, on the North Shore and on the South Shore. Reach us at 514 316-2973 or through the form on airgreen.ca to schedule your visit.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367217836324,"sku":"XP120C00R5B1BAA1A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_PRO_00_PRINCIPALE_66fabb75-e3ab-4cab-ae6e-23d492963d33.png?v=1790086770"},{"product_id":"thermopompe-monobloc-york-wp-de-7-5-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WP 7.5 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eThe 7.5 ton Sun Pro WP: the R-454B generation for commercial projects meant to last\u003c\/h2\u003e\n\u003cp\u003eWhether it is a new building or a rooftop unit that has reached the end of its service life, the owner of a mid-size business today has two generations of refrigerant to choose from. This 7.5 ton YORK Sun Pro WP \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e represents the \u003cstrong\u003eR-454B\u003c\/strong\u003e generation of the Sun Pro line: a rooftop unit fed in \u003cstrong\u003e208\/230 V three-phase\u003c\/strong\u003e, with two scroll compressors, an EER of 12.2, an IEER of 16.0 and a factory-installed refrigerant detector. AirGreen offers it, installs it and maintains it for businesses, offices and buildings in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eA commercial-grade packaged heat pump\u003c\/h3\u003e\n\u003cp\u003eA packaged heat pump gathers the compressors, the coils, the fans and the control in a single outdoor cabinet. Set on a roof curb, on a pad or on a steel structure, it connects directly to the supply and return ducts of the building. In summer it cools; the rest of the year it heats by reversing its cycle, and an electric heat kit can top up its capacity in deep cold. No equipment takes up the sales floor, the stockroom or the drop ceiling, and our technicians carry out the maintenance on the roof, without disturbing your occupants. Every Sun Pro unit leaves the factory charged with refrigerant, wired, piped and tested, which simplifies the work in the field.\u003c\/p\u003e\n\u003ch3\u003eWP090 or XP090: what the R-454B generation changes\u003c\/h3\u003e\n\u003cp\u003eAirGreen also offers the R-410A version in the same size, the Sun Pro XP090. Both units share a cabinet of the same dimensions and an identical weight, but their cooling ratings differ. Here is the comparison, taken from the YORK technical guides for each series:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eWP090 (R-454B)\u003c\/th\u003e\n\u003cth\u003eXP090 (R-410A)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e96,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e92,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER\u003c\/td\u003e\n\u003ctd\u003e12.2\u003c\/td\u003e\n\u003ctd\u003e11.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIEER with IntelliSpeed\u003c\/td\u003e\n\u003ctd\u003e16.0\u003c\/td\u003e\n\u003ctd\u003e14.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e87,000 BTU\/h, COP of 3.5\u003c\/td\u003e\n\u003ctd\u003e87,000 BTU\/h, COP of 3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e51,000 BTU\/h, COP of 2.25\u003c\/td\u003e\n\u003ctd\u003e51,000 BTU\/h, COP of 2.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal airflow\u003c\/td\u003e\n\u003ctd\u003e3,000 CFM\u003c\/td\u003e\n\u003ctd\u003e3,000 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (width x length x height)\u003c\/td\u003e\n\u003ctd\u003e59 x 89 x 50.75 in.\u003c\/td\u003e\n\u003ctd\u003e59 x 89 x 50.75 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating weight\u003c\/td\u003e\n\u003ctd\u003e1,090 lb\u003c\/td\u003e\n\u003ctd\u003e1,090 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eIn heating, both units post the same ratings. In cooling, the WP delivers 4,000 BTU\/h more in net cooling, with an EER one point higher and an IEER 1.4 point higher. Since the footprint and the weight are the same, the choice comes down to the refrigerant and to the cooling performance, and not to the space available on the roof.\u003c\/p\u003e\n\u003ch3\u003eR-454B and the refrigerant detection system\u003c\/h3\u003e\n\u003cp\u003eR-454B is a class A2L refrigerant with a low global warming potential. Each of the two refrigerant circuits of the WP090 holds 12 lb 0 oz of it. According to its nomenclature, this model ships with the \u003cstrong\u003erefrigerant detection system\u003c\/strong\u003e (RDS): built-in sensors, tied to the unit control, automatically start a dilution sequence and set off an alarm when they detect refrigerant in the cabinet, at a concentration matching 25% of the lower flammability limit.\u003c\/p\u003e\n\u003ch3\u003eTechnical data for the WP090C00R2BABAA1A1\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNominal capacity: 7.5 tons (90,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 96,000 BTU\/h (99,000 BTU\/h gross capacity)\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 87,000 BTU\/h, COP of 3.5\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 51,000 BTU\/h, COP of 2.25\u003c\/li\u003e\n\u003cli\u003eEfficiency: EER of 12.2 and IEER of 16.0\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 3,000 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V, three-phase, 60 Hz (applied voltage from 187 to 252 V)\u003c\/li\u003e\n\u003cli\u003eCompressors: 2 scroll on independent circuits, stages of 50% and 100%\u003c\/li\u003e\n\u003cli\u003eOutdoor coil: 29.0 ft², two rows, split-face circuiting; indoor coil: 13.2 ft², four rows; thermostatic expansion valves (TXV)\u003c\/li\u003e\n\u003cli\u003eDimensions (width x length x height): 59 x 89 x 50.75 in.\u003c\/li\u003e\n\u003cli\u003eWeight: 1,090 lb operating, 1,095 lb shipping\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level (AHRI 270): 83 dB(A)\u003c\/li\u003e\n\u003cli\u003eFilters: four 24 x 20 x 2 in. disposable filters\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe factory configuration, option by option\u003c\/h3\u003e\n\u003cp\u003eRead against the nomenclature of the YORK technical guide, model number WP090C00R2BABAA1A1 describes the following equipment:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e with a high static pressure belt drive (3 HP motor): the supply fan speed varies according to the number of compressors or heating stages that are running.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEconomizer\u003c\/strong\u003e with a barometric relief damper, able to admit up to 100% outdoor air.\u003c\/li\u003e\n\u003cli\u003eRefrigerant detection system (RDS) and phase monitor, which stops the unit in the event of a lost phase or a reversed rotation.\u003c\/li\u003e\n\u003cli\u003eStand-alone Smart Equipment control, compatible with a thermostat or a zone sensor.\u003c\/li\u003e\n\u003cli\u003eStandard coils, without E-Coat coating, 2 in. disposable filters and standard cabinet.\u003c\/li\u003e\n\u003cli\u003eNo factory-installed electric heat, no disconnect switch and no convenience outlet: these are added in the field according to your needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTwo stages and a variable-speed fan\u003c\/h3\u003e\n\u003cp\u003eThe two compressors feed two independent refrigerant circuits, each with its own filter drier and its high and low pressure switches. On a mild day, a single compressor delivers half the capacity; the second starts when occupancy, lighting and sun add up. With the IntelliSpeed drive, the supply fan slows down on the first stage, then speeds up on the second, and the minimum position of the economizer can follow the drive frequency. It is this part-load operation that the IEER of 16.0 reflects, while the EER of 12.2 describes performance at full load. A compressor lead-lag function, selectable on the control board, also evens out their run hours.\u003c\/p\u003e\n\u003cp\u003eThe economizer on this model comes with AMCA 511 class 1A low-leakage dampers, which hold leakage to 3 CFM per square foot at 1 in. of static pressure, and every economizer goes through a 60,000 cycle test. Its modulating spring-return actuators open the outdoor air as the return closes, to cool without the compressor in the shoulder seasons.\u003c\/p\u003e\n\u003ch3\u003e208\/230 V supply and backup heat\u003c\/h3\u003e\n\u003cp\u003eAccording to the YORK electrical tables, this configuration with a high static pressure motor, without a powered convenience outlet, calls for a minimum circuit ampacity (MCA) of 43.8 A and a protection of no more than 50 A without electric heat. Four heat kits are planned for this size: E09, E18, E24 and E36. They deliver 6.8, 13.5, 18 and 25.5 kW at 208 V respectively, or 9, 18, 24 and 34 kW at 230 V; from the E18 up, they work in two stages, and all are designed for a single point of supply. With the E36 kit, the MCA reaches 132.3 A at 208 V and 146.1 A at 230 V. Since the heat pump delivers 87,000 BTU\/h at 47 °F and 51,000 BTU\/h at 17 °F, we choose the kit from the actual heat loss of the building and the capacity of your electrical entrance.\u003c\/p\u003e\n\u003ch3\u003eDesigned for maintenance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTool-free hinged panels for the control box, the compressors, the filters, the motor and the supply fan, screwed shut at the factory to block access by unauthorized people.\u003c\/li\u003e\n\u003cli\u003eService windows in both condenser walls to clean and inspect the coils.\u003c\/li\u003e\n\u003cli\u003eNon-corrosive condensate pan that slides out of the unit from the back, with a rigidly mounted 3\/4 in. female drain connection.\u003c\/li\u003e\n\u003cli\u003eFan performance measurement taps outside the cabinet, and a sliding motor and fan assembly.\u003c\/li\u003e\n\u003cli\u003eA second nameplate inside the control door, sheltered from the weather.\u003c\/li\u003e\n\u003cli\u003eSmart Equipment control with an LCD display, a USB port, a fault history and lockout of only the compressor concerned after three trips in two hours.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGetting the rooftop installation right\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof curb:\u003c\/strong\u003e YORK curbs of 8 in. (1RC0470) or 14 in. (1RC0471), with an insulated deck, shipped knocked down; a 10 in. transition curb (1RC0472) picks up the footprint of an older Sunline unit of 7.5 to 12.5 tons.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifting:\u003c\/strong\u003e full perimeter base rails with lifting holes for the crane and lift truck access on three sides.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 72 in. above, 36 in. at the front, at the back and on the left, 12 in. on the right; the unit can sit on a combustible floor or on a class A, B or C roof covering.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDucts:\u003c\/strong\u003e conversion between a side connection and a bottom connection by moving the factory covers, with no panel cutting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating range:\u003c\/strong\u003e cooling down to 0 °F (-17.8 °C) outdoors for the comfort of the occupants thanks to the built-in low ambient control, and operation up to 125 °F (52 °C).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAirGreen, from the estimate to the maintenance of your Sun Pro WP\u003c\/h2\u003e\n\u003cp\u003eIt all starts with a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e. We survey the area and the occupancy of your space, the condition of the ducts, the capacity of your three-phase entrance and the roof access for the crane, then we lay out clearly the two 7.5 ton options, R-454B and R-410A. Our crews then install the unit, set the IntelliSpeed drive, the economizer and the Smart Equipment control at commissioning, and handle the scheduled maintenance: filters, coils, belt, condensate pan and a read of the fault history.\u003c\/p\u003e\n\u003cp\u003eAn HVAC contractor based in Montreal, AirGreen serves Laval, Longueuil, the North Shore and the South Shore with quick, efficient service. Call 514 316-2973 or fill out the form on airgreen.ca to plan your visit: we answer quickly with a detailed quote.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367306539300,"sku":"WP090C00R2BABAA1A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_PRO_00_PRINCIPALE_4e9d37e7-5bd4-4da2-a786-821979c2c495.png?v=1790086821"},{"product_id":"thermopompe-monobloc-york-xp-de-12-5-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XP 12.5 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eAt the top of the Sun Pro range: 12.5 tons for the largest commercial floor areas\u003c\/h2\u003e\n\u003cp\u003eA supermarket with doors opening non-stop, a reception hall that goes from empty to full in one evening, a gym where classes follow one after the other, a big-box store with endless aisles: these buildings call for a lot of capacity and a lot of air. The YORK Sun Pro XP150 \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e, fed by \u003cstrong\u003e208\/230 V three-phase\u003c\/strong\u003e, is the largest model in a series that runs from 6.5 to 12.5 tons, with a longer cabinet, four condenser fans and a rated airflow of 4,600 CFM. AirGreen takes care of the sizing, the installation and the maintenance in Montreal, Laval and Longueuil, as well as on the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eA single cabinet on the roof, a clear sales floor\u003c\/h3\u003e\n\u003cp\u003eA packaged heat pump houses the controls, the compressors, the coils and the fans in a single outdoor cabinet. The unit sits on a roof curb, a pad or a frame, then connects to the duct system, on the supply side and the return side; it cools in summer and heats the rest of the year. No mechanical room to plan for, nothing in the sales floor or in the drop ceiling, and maintenance carried out on the roof, without closing an aisle or moving a banquet. Every XP150 leaves the factory wired, tested and charged with \u003cstrong\u003eR-410A\u003c\/strong\u003e, the proven refrigerant of the previous generation.\u003c\/p\u003e\n\n\u003ch3\u003eKey characteristics of the XP150C00R2B1BAA1A3\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eRated capacity: 12.5 tons (150,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eAHRI net cooling: 141,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 138,000 BTU\/h, COP of 3.3\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 82,000 BTU\/h, COP of 2.15\u003c\/li\u003e\n\u003cli\u003eEfficiency: 10.6 EER, 14.5 IEER with IntelliSpeed\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V, three-phase, 60 Hz (187 to 252 V applied)\u003c\/li\u003e\n\u003cli\u003eCompressors: 2 scroll on independent circuits (stages of 50% and 100%)\u003c\/li\u003e\n\u003cli\u003eRated airflow: 4,600 CFM (ft³\/min), 5 HP motor\u003c\/li\u003e\n\u003cli\u003eCondenser: 4 fans of 24 in., 14,000 CFM in total\u003c\/li\u003e\n\u003cli\u003eDimensions (length x width x height): 119-7\/16 x 59 x 50-3\/4 in.\u003c\/li\u003e\n\u003cli\u003eOperating weight: 1,403 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEER, IEER and two stages: reading the efficiency of a 12.5 ton unit\u003c\/h3\u003e\n\u003cp\u003eYou will find neither SEER nor HSPF on the data sheet of this model: from 6 tons up, a unit is compared in EER and in IEER. The \u003cstrong\u003e10.6 EER\u003c\/strong\u003e measures full-load performance; the \u003cstrong\u003e14.5 IEER\u003c\/strong\u003e, obtained with the IntelliSpeed drive, weighs performance at part load. That is where the two scroll compressors come in, delivering 50% and then 100% of the capacity: in a supermarket, the first one can be enough on a Tuesday morning, and the second starts on Saturday afternoon, when the lines at the checkouts get longer. The drive then sets the blower speed according to the number of active compressors.\u003c\/p\u003e\n\n\u003ch3\u003eA longer cabinet, four fans and a 5 HP motor\u003c\/h3\u003e\n\u003cp\u003eWhere the 6.5 to 10 ton models measure 89 in., the XP150 stretches to 119-7\/16 in. That length holds a condenser coil of 47.5 ft² (29.0 ft² on the other sizes) and \u003cstrong\u003efour 24 in. fans\u003c\/strong\u003e with direct drive instead of two, moving 14,000 CFM. Inside the cabinet, a 5 HP motor (184T frame), fitted with an adjustable-pitch sheave, belt-drives a 15 x 15 in. double-inlet centrifugal wheel; motor and wheel form a slide-out assembly. The tables in the guide cover external static pressures from 0.2 to 2.0 in. of water column, useful for long duct systems.\u003c\/p\u003e\n\n\u003ch3\u003eDecoding the model number\u003c\/h3\u003e\n\u003cp\u003eAccording to the YORK nomenclature, this number designates a 208\/230 V three-phase unit whose high static pressure drive is controlled by the \u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e, with an \u003cstrong\u003eeconomizer with barometric relief damper\u003c\/strong\u003e, a phase monitor, a Smart Equipment control in stand-alone mode, 2 in. disposable filters, standard coils and cabinet. Fitted with low-leakage AMCA 511 Class 1A dampers, the economizer admits up to 100% outdoor air and takes over from the compressors as soon as the outdoor air allows it. The unit is delivered with no service option (disconnect, convenience outlet) and with no electric heat.\u003c\/p\u003e\n\n\u003ch3\u003eElectric heat kits and ampacity: sizing the three-phase service\u003c\/h3\u003e\n\u003cp\u003eIn heat pump mode, the XP150 delivers 138,000 BTU\/h at 47 °F and 82,000 BTU\/h at 17 °F. When the cold gets sharper, YORK offers for this size \u003cstrong\u003eelectric heat\u003c\/strong\u003e kits in four sizes, namely 18, 24, 36 and 54 kW, two-stage and with single-point power. Without electric heat, the YORK tables drawn up for the high static pressure motor, in the version without a powered convenience outlet, give an \u003cstrong\u003eMCA (minimum circuit ampacity) of 78.4 A\u003c\/strong\u003e and a protection of 100 A at most. With the 54 kW kit, the MCA reaches 166.9 A at 208 V and 180.7 A at 230 V. The voltage counts too: this kit delivers 54 kW at 230 V, but 40.6 kW at 208 V.\u003c\/p\u003e\n\n\u003ch3\u003eSmart Equipment and phase monitor: a hard-working unit, closely watched\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e board receives its temperature sensors at the factory (supply air, return air, outdoor air). Its LCD screen displays the fault codes, whose history the USB port keeps. The board also protects the unit during a voltage drop, while the \u003cstrong\u003ephase monitor\u003c\/strong\u003e shuts it down if it detects a missing phase or a reversed rotation, two risks specific to three-phase power. Three safety trips in less than two hours lock out only the associated compressor. Finally, the built-in low-ambient control allows cooling down to 0 °F (-17.8 °C) outdoors, in a comfort application and with no additional component: useful when a hall full of guests warms the air well before spring.\u003c\/p\u003e\n\n\u003ch3\u003eCrane, roof curb and connections: preparing the job site\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStructure:\u003c\/strong\u003e 1,403 lb in operation for the base unit, plus 85 lb for the economizer according to the accessories table. The guide also gives the load per support point and the centre of gravity, useful to the structural engineer.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLifting:\u003c\/strong\u003e the rails that run around the base are drilled with lifting holes for the crane slings and accept the forks of a forklift on three sides; the lift is preferably planned outside business hours.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoof curb:\u003c\/strong\u003e YORK offers curbs with insulated deck, 8 or 14 in. high and shipped knocked down, as well as a 10 in. transition adapter intended for Sunline curbs from 7.5 to 12.5 tons only. Since the XP150 cabinet is longer, we confirm the exact curb with the distributor before ordering; it has to rise at least 8 in. above the finished roof.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearances:\u003c\/strong\u003e 72 in. clear above the four fans, 12 in. on the right side, 36 in. for the front, the back and the left side.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnections:\u003c\/strong\u003e a single electrical entry, on the side or from below, and a disconnect to plan for in the field; the ducts connect underneath or on the side, with no panel cutting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFrom the visit to the start-up: AirGreen takes charge of your 12.5 ton unit\u003c\/h2\u003e\n\u003cp\u003eOur \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e covers the floor area and the height of the space, the occupancy peaks, the ducts, the three-phase service, the roof structure and the crane access; it makes it possible to confirm the size. We then organize the crane, install the unit and commission it: balancing the 4,600 CFM, setting the IntelliSpeed drive, the economizer and the Smart Equipment control. \u003cstrong\u003ePlanned maintenance\u003c\/strong\u003e then takes over: four 24 x 20 x 2 in. filters, belt, coils cleaned through the service windows, slide-out condensate pan and fault history.\u003c\/p\u003e\n\u003cp\u003eOur territory covers Montreal, Laval, Longueuil, the North Shore and the South Shore, with short response times and careful work. To book your visit, call 514 316-2973 or send your request through the form on airgreen.ca; a detailed quote follows quickly.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367635398948,"sku":"XP150C00R2B1BAA1A3","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_PRO_00_PRINCIPALE_9af310f9-ad90-4802-94be-0fb76bba0f71.png?v=1790086978"},{"product_id":"thermopompe-monobloc-york-xp-de-10-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York XP 10 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003eYour ventilation supplies the fresh air, this 10 ton rooftop unit supplies the comfort\u003c\/h2\u003e\n\u003cp\u003eIf your building already gets its fresh air from an \u003cstrong\u003eair exchanger\u003c\/strong\u003e or from a separate ventilation system, the rooftop unit does not have to take care of it: its job comes down to cooling and heating the return air. That is the mandate of the 10 ton YORK Sun Pro XP model, a \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e fed by \u003cstrong\u003e208\/230 V three-phase\u003c\/strong\u003e and delivered in its base configuration: no economizer, an IntelliSpeed drive, a high static pressure fan and two stages of cooling. An economizer or an outdoor air damper can be added later, as an accessory. AirGreen takes care of the supply, the installation and the maintenance in the greater Montreal area, including Laval and Longueuil as well as the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eTwo units, two clearly separate roles\u003c\/h3\u003e\n\u003cp\u003eIn a packaged unit, no mechanical component is installed inside the building: the two compressors, the two coils, the supply fan and the control board sit in a single outdoor cabinet, installed on the roof on a curb, at grade on a pad or on a frame, then connected to the ducts. In summer, the unit cools; in cold weather, it heats by reversing its cycle, with electric backup heat offered as an accessory. Where the ventilation is independent, the split is simple: the air exchanger renews the air, the packaged unit cools it or heats it. With no economizer, there is no outdoor air damper or actuator to inspect on the roof.\u003c\/p\u003e\n\u003ch3\u003eThe number XP120C00R2A1AAA1A2 in plain language\u003c\/h3\u003e\n\u003cp\u003eRead according to the YORK nomenclature:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSegment\u003c\/th\u003e\n\u003cth\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eXP120\u003c\/td\u003e\n\u003ctd\u003eSun Pro XP, packaged heat pump on R-410A, 10 tons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eC00\u003c\/td\u003e\n\u003ctd\u003eNo factory electric heat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eR\u003c\/td\u003e\n\u003ctd\u003eIntelliSpeed (variable frequency drive) and high static pressure fan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e208\/230 V, three-phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eNo economizer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eNo service option: the disconnect is installed in the field\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eNo optional sensor (no phase monitor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eSmart Equipment board in stand-alone mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eStandard coils, without E-Coat coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eFour disposable 2 in. filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eAirGreen also offers the same capacity in 575 V, with identical ratings, with an economizer and a phase monitor.\u003c\/p\u003e\n\u003ch3\u003eCapacities, ratings and footprint\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCooling: 111,000 BTU\/h of AHRI net cooling for a nominal 10 tons (120,000 BTU\/h); 11.0 EER, 14.5 IEER with IntelliSpeed\u003c\/li\u003e\n\u003cli\u003eHeat pump heating: 102,000 BTU\/h at 47 °F (8.3 °C), COP of 3.5; 59,000 BTU\/h at 17 °F (-8.3 °C), COP of 2.25\u003c\/li\u003e\n\u003cli\u003eFrom 6 tons up, the published ratings are EER and IEER, with no SEER or HSPF\u003c\/li\u003e\n\u003cli\u003eRated airflow: 3,300 CFM\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 187 to 252 V\u003c\/li\u003e\n\u003cli\u003eOutdoor sound level: 83 dBA per AHRI 270\u003c\/li\u003e\n\u003cli\u003eFootprint: 89 in. long, 59 in. wide and 50.75 in. high, for 1,135 lb in operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eA fan for demanding duct systems, two stages for a variable load\u003c\/h3\u003e\n\u003cp\u003eThe supply fan, a belt-driven 15 x 15 in. double-inlet centrifugal wheel, receives the \u003cstrong\u003ehigh static pressure\u003c\/strong\u003e drive: YORK pairs it with a 3 HP motor and a variable-pitch drive sheave that allows the speed to be set between 880 and 1,110 rpm. That choice suits duct systems that impose a higher static pressure, such as long duct runs or runs loaded with accessories. External measurement ports make it possible to check the fan performance without opening a panel.\u003c\/p\u003e\n\u003cp\u003eEach scroll compressor has its own refrigeration circuit: only one runs when demand is moderate, both when it rises. The \u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e then varies the fan speed with the compressors or the heating stages that are active. The 11.0 EER corresponds to full-load operation; the 14.5 IEER weighs performance at several load levels.\u003c\/p\u003e\n\u003ch3\u003eAdding outdoor air later: the accessories YORK provides for\u003c\/h3\u003e\n\u003cp\u003eThe YORK guide provides for these field-installed accessories:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEconomizer\u003c\/strong\u003e 2EE04717625 (50 in. cabinet), for bottom supply or horizontal end return: hoods and barometric relief included, low-leakage dampers meeting AMCA 511 Class 1A, up to 100% outdoor air.\u003c\/li\u003e\n\u003cli\u003eHorizontal economizer for side return (2EE04706924), with barometric relief ordered separately and mounted in the ducts.\u003c\/li\u003e\n\u003cli\u003eMotorized damper (2MD04703824 bottom, 2MD04703924 horizontal), which opens to its preset position, between 0 and 100%, as soon as the indoor fan starts.\u003c\/li\u003e\n\u003cli\u003eManual bottom damper, from 0 to 35% (1FA0413) or from 0 to 100% (1FA0414), with hood and filters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe economizer adds 85 lb in operation, and its static resistance is subtracted from the pressure available at the fan: we take it into account as soon as we set the drive. Once the economizer is installed, its minimum position can follow the drive frequency. Until then, a zone that calls for cooling in winter is served by the compressors, which the low-ambient control lets run down to 0 °F (-17.8 °C) outdoors, for the comfort of the occupants.\u003c\/p\u003e\n\u003ch3\u003e208\/230 V connection: currents and backup heat kits\u003c\/h3\u003e\n\u003cp\u003eYour electrician will take two values from the guide, the same at 208 V and at 230 V: a minimum circuit ampacity (\u003cstrong\u003eMCA\u003c\/strong\u003e) of 47.6 A and a protection of 60 A at most, by means of a dual-element time-delay fuse or an HACR breaker. They apply to the unit as delivered: high static pressure motor, no powered convenience outlet, no electric heat. Adding a power exhaust with the economizer brings the MCA to 53.1 A, the protection staying at 60 A.\u003c\/p\u003e\n\u003cp\u003eFour two-stage backup heat kits, designed for a single-point power connection, suit this size, and their capacity varies with the voltage available:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eKit\u003c\/th\u003e\n\u003cth\u003eAt 208 V\u003c\/th\u003e\n\u003cth\u003eAt 230 V\u003c\/th\u003e\n\u003cth\u003eMinimum airflow\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eE18\u003c\/td\u003e\n\u003ctd\u003e13.5 kW\u003c\/td\u003e\n\u003ctd\u003e18 kW\u003c\/td\u003e\n\u003ctd\u003e3,000 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE24\u003c\/td\u003e\n\u003ctd\u003e18 kW\u003c\/td\u003e\n\u003ctd\u003e24 kW\u003c\/td\u003e\n\u003ctd\u003e3,000 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE36\u003c\/td\u003e\n\u003ctd\u003e25.5 kW\u003c\/td\u003e\n\u003ctd\u003e34 kW\u003c\/td\u003e\n\u003ctd\u003e3,000 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eE54\u003c\/td\u003e\n\u003ctd\u003e40.6 kW\u003c\/td\u003e\n\u003ctd\u003e54 kW\u003c\/td\u003e\n\u003ctd\u003e3,500 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWith the E54, the fan has to go beyond the nominal 3,300 CFM, and the choice of kit follows the heat loss of the building.\u003c\/p\u003e\n\u003ch3\u003eWhat your technician finds when opening the unit\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSmart Equipment\u003c\/strong\u003e board accepts a 24 V thermostat with two stages of heating and cooling, with or without an economizer, or a zone sensor. Its USB port gives access to the fault history and the start-up reports. The board only locks out a compressor on the third trip of the same safety within two hours.\u003c\/p\u003e\n\u003cp\u003eThe access panels open without tools, the four disposable filters measure 24 x 20 x 2 in., and the composite condensate pan slides out the back of the unit.\u003c\/p\u003e\n\u003ch3\u003eOn the roof: loads, curb and clearances\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLoads of 209 to 369 lb at the four support points, to be passed on to the structural engineer.\u003c\/li\u003e\n\u003cli\u003eYORK roof curbs available in 8 and 14 in. heights, with insulated deck; 10 in. transition adapter for the curb of an older Sunline (7.5 to 12.5 ton models).\u003c\/li\u003e\n\u003cli\u003eClear space of 12 in. on the right, 36 in. on the three other sides and 72 in. above.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrom the on-site survey to the maintenance: AirGreen runs your 10 ton project\u003c\/h2\u003e\n\u003cp\u003eEvery project opens with a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e, which covers the ventilation as much as the cooling: existing fresh air supply, future needs, ducts and static pressure, the actual voltage of your three-phase service and crane access. If an economizer or a damper has to be planned, the quote says so.\u003c\/p\u003e\n\u003cp\u003eOur teams install the unit, adjust the sheave, set the IntelliSpeed drive and the Smart Equipment board, then come back at planned intervals for the filters, the belt, the coils, the condensate pan and the fault history. Our technicians travel quickly throughout our territory, from the North Shore to the South Shore by way of Laval, Montreal and Longueuil. To book your estimate, call 514 316-2973 or request it through the form on airgreen.ca.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56367652831524,"sku":"XP120C00R2A1AAA1A2","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_PRO_00_PRINCIPALE_a52d8f13-20d2-443e-8f39-1fa5f37b3125.png?v=1790086978"},{"product_id":"thermopompe-monobloc-york-wp-de-10-tonnes-triphase-montreal-laval-longueuil-rive-sud-et-rive-nord","title":"Packaged Heat Pump System York WP 10 Ton Three-Phase | Montreal, Laval, Longueuil, South Shore and North Shore","description":"\u003ch2\u003e10 tons of cooling and heating under the supervision of your BAS\u003c\/h2\u003e\n\u003cp\u003eIn a building supervised by a building automation system (BAS), every rooftop unit has to fit into the existing communication network. The YORK Sun Pro WP, a 10 ton packaged heat pump on R-454B fed by 208\/230 V three-phase, leaves the factory with its \u003cstrong\u003eBACnet MS\/TP communication card\u003c\/strong\u003e, its high static pressure IntelliSpeed drive and its refrigerant detection system. It has no \u003cstrong\u003eeconomizer\u003c\/strong\u003e — the fresh air comes from separate ventilation. AirGreen handles the supply, the installation and the follow-up in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\u003ch3\u003eOne cabinet on the roof, one unit on the network\u003c\/h3\u003e\n\u003cp\u003eA \u003cstrong\u003epackaged heat pump\u003c\/strong\u003e brings the refrigeration circuit and the ventilation together under one outdoor shell: two scroll compressors on separate circuits, the coils, the supply fan and the controls. On the roof or at grade, it connects to the building's duct system, cools in two stages (50% and 100%) and switches to heating by reversing the cycle. For your operations team, it is a single piece of equipment, factory-tested, to tie into the BAS and to maintain.\u003c\/p\u003e\n\u003ch3\u003eA factory BACnet MS\/TP gateway, programmable to Modbus or N2\u003c\/h3\u003e\n\u003cp\u003eThe C control code designates the Smart Equipment option with communication: the full Smart Equipment control, paired with a \u003cstrong\u003eBACnet MS\/TP\u003c\/strong\u003e gateway programmable to Modbus or N2. The supply air, return air and outdoor air temperature sensors are factory-installed, and the board monitors the pressure switches of each circuit as well as the supply voltage. The LCD screen displays the fault codes; the USB port is used to pull the history and the start-up reports, and to update the software. The board also manages the minimum supply air setpoint (LLC) and compressor swapping; the control wiring has its own entries.\u003c\/p\u003e\n\u003ch3\u003eAHRI ratings and physical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAHRI net cooling: 116,000 BTU\/h, 11.2 EER, 15.2 IEER\u003c\/li\u003e\n\u003cli\u003eHeating at 47 °F (8.3 °C): 104,000 BTU\/h, COP of 3.5\u003c\/li\u003e\n\u003cli\u003eHeating at 17 °F (-8.3 °C): 60,000 BTU\/h, COP of 2.25\u003c\/li\u003e\n\u003cli\u003ePower supply: 208\/230 V, three-phase, 60 Hz (187 to 252 V range)\u003c\/li\u003e\n\u003cli\u003eRated airflow: 3,300 CFM (ft³\/min)\u003c\/li\u003e\n\u003cli\u003eR-454B charge: 12 lb 0 oz and 11 lb 4 oz depending on the circuit\u003c\/li\u003e\n\u003cli\u003eDimensions and weight: 59 x 89 x 50.75 in., 1,135 lb operating\u003c\/li\u003e\n\u003cli\u003eFiltration: 4 disposable 24 x 20 x 2 in. filters\u003c\/li\u003e\n\u003cli\u003eOutdoor sound rating (AHRI 270): 83 dB(A)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHigh static pressure IntelliSpeed: reserve for your ducts\u003c\/h3\u003e\n\u003cp\u003eThe R code pairs the \u003cstrong\u003eIntelliSpeed drive\u003c\/strong\u003e with the high static pressure drive package: a 3 HP motor instead of the standard 2 HP, good for 3.45 bhp continuous, and a speed adjustable from 880 to 1,110 rpm. The YORK tables for the WP120 go up to 2.0 in. of water column of external static pressure, a useful margin for long duct runs. The drive then modulates the speed with the number of compressors or heating stages running, which is what the 15.2 IEER reflects, since it weighs performance at part load.\u003c\/p\u003e\n\u003ch3\u003eR-454B and built-in leak detection\u003c\/h3\u003e\n\u003cp\u003eAn A2L class refrigerant, \u003cstrong\u003eR-454B\u003c\/strong\u003e has a low global warming potential. The \u003cstrong\u003erefrigerant detection system\u003c\/strong\u003e (RDS) of the WP120 is factory-installed: its sensors, wired to the board, are placed to spot a leak in the cabinet quickly. As soon as the concentration reaches the equivalent of 25% of the lower flammability limit, the system raises the alarm and automatically starts diluting the refrigerant.\u003c\/p\u003e\n\u003ch3\u003eNo economizer, as a complement to your ventilation\u003c\/h3\u003e\n\u003cp\u003eThe A code of the outdoor air option means \"no economizer\": the fresh air stays with your air exchanger or your ventilation unit. If interior spaces call for cooling in winter, the low-ambient control provides comfort cooling down to 0 °F (-17.8 °C) outdoors; for a server room, you first have to check with the YORK applications department.\u003c\/p\u003e\n\u003cp\u003eShould outdoor air be brought in by the unit, the guide provides for the \"BAS Ready\" economizer (ready for the BAS) for the 50 in. cabinet (2EE04709825), the 208\/230 V power exhaust (2PE04704706) and the single (2EC0401) or dual (2EC0402) enthalpy controls. The minimum economizer opening can then be slaved to the drive frequency.\u003c\/p\u003e\n\u003ch3\u003eCompared with the R-410A XP120\u003c\/h3\u003e\n\u003cp\u003eWe also offer the XP120, the proven R-410A counterpart from the previous generation. The cabinet (59 x 89 x 50.75 in.), the weight (1,135 lb) and the rated airflow (3,300 CFM) are identical; here are the differences according to the YORK guides:\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eCriterion\u003c\/th\u003e\n\u003cth\u003eWP120 (R-454B)\u003c\/th\u003e\n\u003cth\u003eXP120 (R-410A)\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI net cooling\u003c\/td\u003e\n\u003ctd\u003e116,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e111,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER and IEER\u003c\/td\u003e\n\u003ctd\u003e11.2 and 15.2\u003c\/td\u003e\n\u003ctd\u003e11.0 and 14.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 47 °F (8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e104,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e102,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating at 17 °F (-8.3 °C)\u003c\/td\u003e\n\u003ctd\u003e60,000 BTU\/h\u003c\/td\u003e\n\u003ctd\u003e59,000 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA and maximum protection at 208\/230 V\u003c\/td\u003e\n\u003ctd\u003e52.5 A and 60 A\u003c\/td\u003e\n\u003ctd\u003e47.6 A and 60 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl in the configuration offered\u003c\/td\u003e\n\u003ctd\u003eBACnet MS\/TP, Modbus and N2 card\u003c\/td\u003e\n\u003ctd\u003eStand-alone Smart Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant detection\u003c\/td\u003e\n\u003ctd\u003eFactory RDS\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eWith identical COPs (3.5 and 2.25), the WP120 takes the lead on cooling and arrives ready for the BAS; the XP120 suits a building run by thermostat or a fleet already on R-410A.\u003c\/p\u003e\n\u003ch3\u003eElectrical connection and backup heat\u003c\/h3\u003e\n\u003cp\u003eAs delivered, the unit calls for a circuit with a \u003cstrong\u003eminimum circuit ampacity\u003c\/strong\u003e (MCA) of 52.5 A, protected by a dual-element time-delay fuse or an HACR breaker of 60 A maximum, at 208 V as at 230 V; adding a power exhaust brings those values to 58 A and 70 A. The power feed enters at a single point, on the side or underneath, and the disconnect, not supplied from the factory, is installed in the field.\u003c\/p\u003e\n\u003cp\u003eThe 10 ton size accepts four electric heat kits, all two-stage and connected to the same power point as the unit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eE18 (2TP04531825): 13.5 kW at 208 V, 18 kW at 230 V\u003c\/li\u003e\n\u003cli\u003eE24 (2TP04532425): 18 kW at 208 V, 24 kW at 230 V\u003c\/li\u003e\n\u003cli\u003eE36 (2TP04533625): 25.5 kW at 208 V, 34 kW at 230 V\u003c\/li\u003e\n\u003cli\u003eE54 (2TP04525425): 40.6 kW at 208 V, 54 kW at 230 V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe minimum airflow is 3,000 CFM, or 3,500 CFM with the E54. At 208 V, the MCA reaches 99.4 A with the E18 and 141 A with the E36, for example. The choice of kit follows your heat load and the spare capacity of your electrical service.\u003c\/p\u003e\n\u003ch3\u003eWhat to plan before the lift\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eYORK roof curbs with insulated deck, shipped knocked down: 1RC0470 (8 in.) or 1RC0471 (14 in.); the 1RC0472 adapter (10 in.) sits on the existing curb of a Sunline from 7.5 to 12.5 tons.\u003c\/li\u003e\n\u003cli\u003ePerimeter base rails drilled for the crane; on four supports, the load ranges from 209 to 369 lb depending on the corner.\u003c\/li\u003e\n\u003cli\u003eClearances: 36 in. in front, behind and on the left, 12 in. on the right, 72 in. above.\u003c\/li\u003e\n\u003cli\u003eSide connection: the installer moves the two factory covers to the bottom openings, without cutting a panel.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAirGreen coordinates your project with the integrator and the electrician\u003c\/h2\u003e\n\u003cp\u003eAirGreen's \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e runs from the roof to the supervision station: ducts and static pressure, heat load, three-phase service, existing curb, crane access and the protocol of your BAS. The quote then compares the WP120 and the XP120.\u003c\/p\u003e\n\u003cp\u003eAt installation, we coordinate the crane, the electrician and your integrator, adjust the pulley and the drive to the measured airflow, then commission the board on the BAS network. Our technicians then take care of the planned maintenance and, from Montreal, get quickly to Laval, Longueuil, the North Shore and the South Shore. To book your estimate visit, reach us at 514 316-2973 or write to us from airgreen.ca.\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56368011116836,"sku":"WP120C00R2AAACA1A1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MONOBLOC_YORK_SUN_PRO_00_PRINCIPALE_f831ce39-d1fa-49c8-9e12-1c6d30b29199.png?v=1790086979"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/collections\/THERMOPOMPE_MONOBLOC_YORK_SUN_PRO_00_PRINCIPALE_4e9d37e7-5bd4-4da2-a786-821979c2c495.png?v=1790171265","url":"https:\/\/airgreen.ca\/en\/collections\/thermopompe-monobloc-york-sun-pro-wp-xp-montreal-laval-longueuil-rive-sud-nord.oembed","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}