{"title":"Kinghome POLARIS R32 Wall-Mounted Heat Pump | Montreal, Laval, South Shore \u0026 North Shore","description":null,"products":[{"product_id":"thermopompe-murale-kinghome-polaris-r32-9000-btu","title":"KINGHOME Polaris R32 Wall-Mounted Heat Pump | 9000 BTU","description":"\u003ch2\u003eThe Right Unit for the Room That Has Never Been Comfortable\u003c\/h2\u003e\n\u003cp\u003eAlmost every home has one: the bedroom above the garage that stays icy in February, the basement office that becomes unbearable in July, the corner room with two exterior walls and a large window. The \u003cstrong\u003eKINGHOME Polaris R32 | 9,000 BTU Wall-Mounted Heat Pump\u003c\/strong\u003e exists precisely for this kind of situation. At AirGreen, we install this size in primary bedrooms, home offices, finished basements, studios, and additions where the rest of the system simply cannot keep up.\u003c\/p\u003e\n\u003cp\u003eIt is the smallest model in the POLARIS series, and it is also the most efficient: \u003cstrong\u003e26.5 SEER2\u003c\/strong\u003e, \u003cstrong\u003e10.6 HSPF2\u003c\/strong\u003e, and an \u003cstrong\u003eEER2 of 16\u003c\/strong\u003e. These three figures make it one of the highest-rated wall-mounted units we offer, across all brands.\u003c\/p\u003e\n\u003ch3\u003eWhat a 9,000 BTU capacity really solves\u003c\/h3\u003e\n\u003cp\u003eThe rated cooling capacity is \u003cstrong\u003e9,100 BTU\/h\u003c\/strong\u003e, with a modulation range from \u003cstrong\u003e2,730 to 12,965 BTU\/h\u003c\/strong\u003e. This range is more important than the rated figure. A \u003cstrong\u003etriple rotary inverter-driven compressor\u003c\/strong\u003e does not operate simply on or off: it drops to approximately 2,700 BTU\/h when the room requires little, and rises to nearly 13,000 BTU\/h during a heat wave. This produces a stable temperature rather than alternating between too cold and too hot.\u003c\/p\u003e\n\u003cp\u003eIn practice, this size is suitable for an enclosed or semi-open room of approximately 250 to 400 square feet, depending on insulation, orientation, ceiling height, and window area. A well-insulated north-facing bedroom does not have the same needs as a south-facing living room with a large picture window.\u003c\/p\u003e\n\u003ch3\u003eThe oversizing trap\u003c\/h3\u003e\n\u003cp\u003eThe most common mistake we encounter in \u003cstrong\u003ewall-mounted heat pump\u003c\/strong\u003e projects is not choosing one that is too small. It is choosing one that is too large. An oversized unit reaches the requested temperature very quickly, then reduces its output or shuts off. The problem is that \u003cstrong\u003edehumidification\u003c\/strong\u003e takes place while the coil is running. A unit that operates too little removes little moisture, and the room becomes cold and clammy rather than cool and dry.\u003c\/p\u003e\n\u003cp\u003eThe 9,000 BTU POLARIS removes up to \u003cstrong\u003e0.8 litres of moisture per hour\u003c\/strong\u003e. In a bedroom, that is more than sufficient, and above all, the unit runs long enough to do it properly. A 12,000 BTU unit installed in the same location would often provide a less comfortable result at a higher price.\u003c\/p\u003e\n\u003ch3\u003eThe number to watch for winter: 15,000 BTU at -8 °C\u003c\/h3\u003e\n\u003cp\u003eMany customers compare units based on rated capacity. In Quebec, that is not the right criterion. What matters is the heating capacity when it is truly cold outside.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAt \u003cstrong\u003e8 °C\u003c\/strong\u003e: 10,500 BTU\/h\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-8 °C\u003c\/strong\u003e: \u003cstrong\u003e15,000 BTU\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-15 °C\u003c\/strong\u003e: 13,000 BTU\/h, with a COP of 1.9\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe figures may seem surprising: the unit produces more heat at -8 °C than at 8 °C. This is normal for an inverter system. In mild conditions, the compressor modulates downward because the room does not need more. When demand increases, it speeds up. The published capacity at -8 °C corresponds to this higher operating level, and it is exactly the data Hydro-Québec uses in its own lists.\u003c\/p\u003e\n\u003cp\u003eIn practical terms, a bedroom requiring 8,000 BTU\/h at -20 °C remains served by this unit. The heating operating range extends down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e, and the unit carries the \u003cstrong\u003eENERGY STAR cold-climate designation\u003c\/strong\u003e, which is not a marketing claim but a separate certification.\u003c\/p\u003e\n\u003ch3\u003e20 dB(A): silence treated as a specification\u003c\/h3\u003e\n\u003cp\u003eThe indoor sound level ranges from \u003cstrong\u003e20 to 42 dB(A)\u003c\/strong\u003e. The lower value deserves some context: a quiet bedroom at night is around 30 dB(A). At minimum speed, this unit is therefore quieter than the room itself.\u003c\/p\u003e\n\u003cp\u003eFor a bedroom, this is often the deciding factor. We have seen customers replace a perfectly functional unit simply because they could no longer stand hearing it start at night. Airflow ranges from \u003cstrong\u003e194 to 353 CFM\u003c\/strong\u003e, allowing air to circulate without creating a direct draft over the bed or desk. The outdoor unit, meanwhile, is rated at \u003cstrong\u003e55 dB(A)\u003c\/strong\u003e: something to consider if it must be installed near a neighbour's window, a common situation in \u003cstrong\u003eMontreal\u003c\/strong\u003e plexes.\u003c\/p\u003e\n\u003ch3\u003eR-32 refrigerant and G-AI 2.0 smart control\u003c\/h3\u003e\n\u003cp\u003eThe POLARIS uses \u003cstrong\u003eR-32\u003c\/strong\u003e, whose global warming potential is significantly lower than that of the R-410A it replaces. This refrigerant also transfers heat more effectively, allowing for a lower charge for equivalent capacity: \u003cstrong\u003e38.1 ounces\u003c\/strong\u003e for this model.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eG-AI 2.0\u003c\/strong\u003e control continuously adjusts the compressor and fan speed according to the difference between the setpoint and the actual temperature. Kinghome claims energy savings of up to 15% compared with the previous generation. Other features include \u003cstrong\u003ebuilt-in Wi-Fi\u003c\/strong\u003e with app control, \u003cstrong\u003e3D airflow\u003c\/strong\u003e, humidity control, Turbo mode, and automatic coil cleaning.\u003c\/p\u003e\n\u003ch2\u003eWhat we check before confirming an installation\u003c\/h2\u003e\n\u003cp\u003eA specification sheet does not say whether a unit is suitable for a particular building. Here is what we look at during an assessment in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, or the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eElectrical supply\u003c\/h3\u003e\n\u003cp\u003eThis model requires a \u003cstrong\u003e208-230 V single-phase\u003c\/strong\u003e supply, a \u003cstrong\u003eminimum circuit ampacity (MCA) of 13 A\u003c\/strong\u003e, and a \u003cstrong\u003emaximum protection of 15 A\u003c\/strong\u003e. These are modest requirements, and that is a real advantage of the 9,000 BTU model: in many older homes in the Plateau, Verdun, or Rosemont, there is still room in the panel for a 15 A circuit, whereas a 30 A circuit would require upgrading the electrical service. We always check the panel before confirming a quote.\u003c\/p\u003e\n\u003ch3\u003eOutdoor unit location\u003c\/h3\u003e\n\u003cp\u003eThe outdoor unit measures \u003cstrong\u003e34.4 x 14.8 x 21.8 inches\u003c\/strong\u003e and weighs \u003cstrong\u003e81.6 pounds\u003c\/strong\u003e. Its compact size makes installation on a wall bracket easier, a solution we favour in Quebec: it keeps the unit above accumulated snow and allows defrost water to drain properly. A unit installed too low eventually becomes blocked after two storms, defrosts more often, consumes more energy, and makes more noise.\u003c\/p\u003e\n\u003ch3\u003ePiping\u003c\/h3\u003e\n\u003cp\u003eThe connection uses \u003cstrong\u003e1\/4 and 1\/2 inch\u003c\/strong\u003e lines, with a factory charge for \u003cstrong\u003e25 feet\u003c\/strong\u003e of piping and an allowable length of 10 to 131 feet. Beyond the factory-charged length, refrigerant must be added at a rate of 0.2 ounces per foot. This flexibility matters in triplexes where the indoor unit is at the front of the dwelling and the only available wall for the outdoor unit faces the backyard.\u003c\/p\u003e\n\u003ch3\u003eThe mistakes we correct most often\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eA unit installed facing an obstacle.\u003c\/strong\u003e A tall cabinet, beam, or hallway return diverts the air stream and cancels the benefit of 3D airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA condensate drain without sufficient slope.\u003c\/strong\u003e This is the leading cause of water damage we see on installations done too quickly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAn abbreviated vacuum procedure.\u003c\/strong\u003e Moisture left in the circuit reduces efficiency and shortens the compressor's life. It is not visible at startup, but it will cost you three years later.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFilters that are never cleaned.\u003c\/strong\u003e A clogged filter reduces airflow, and therefore capacity. Maintenance is simple and takes just a few minutes.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eCertification and program eligibility\u003c\/h3\u003e\n\u003cp\u003eThis model is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified, carries the \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e, and is among the units recognized as \u003cstrong\u003eENERGY STAR Most Efficient\u003c\/strong\u003e. Its reference numbers are \u003cstrong\u003eAHRI 218451121\u003c\/strong\u003e and \u003cstrong\u003eENERGY STAR ID 4617798\u003c\/strong\u003e. Keep them: financial assistance programs request them.\u003c\/p\u003e\n\u003cp\u003eFor \u003cstrong\u003eLogisVert\u003c\/strong\u003e eligibility, Hydro-Québec lists are updated regularly, and eligibility is verified model by model as of the installation date. We systematically validate this point when preparing the quote rather than leaving a customer to discover it after the work is complete.\u003c\/p\u003e\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eKinghome offers \u003cstrong\u003e12 years on the compressor and parts\u003c\/strong\u003e for residential applications on registered models, and 5 or 7 years for commercial applications. Registration is a step we handle: an unregistered warranty can become an unpleasant surprise at the first service call.\u003c\/p\u003e\n\u003ch3\u003eWhy choose AirGreen\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAn assessment based on the building, not just the floor area.\u003c\/li\u003e\n\u003cli\u003eEmployed refrigeration technicians, with no improvised subcontracting.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e$5,000,000\u003c\/strong\u003e in commercial general liability insurance.\u003c\/li\u003e\n\u003cli\u003eConnection, vacuuming, startup, and warranty registration completed properly.\u003c\/li\u003e\n\u003cli\u003eAccessible after-sales service in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, \u003cstrong\u003eMontérégie\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the KINGHOME Polaris R32 | 9,000 BTU Wall-Mounted Heat Pump. We will assess the room, check your electrical panel, and provide you with a clear, no-surprises quote.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Kinghome","offers":[{"title":"Default Title","offer_id":56293988565284,"sku":"KWP09R32C3O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_THERMOPOMPE_MURALE_KINGHOME_POLARIS_R32_9000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_57d3a9a6-aedd-4afc-8549-90404fb6a89c.png?v=1789509651"},{"product_id":"thermopompe-murale-kinghome-polaris-r32-12000-btu","title":"KINGHOME Polaris R32 Wall-Mounted Heat Pump | 12000 BTU","description":"\u003ch2\u003eThe format that replaces the most electric baseboard heaters in Quebec\u003c\/h2\u003e\n\u003cp\u003eOf all the \u003cstrong\u003eductless heat pump\u003c\/strong\u003e formats we install, the 12,000 BTU model is the one we install most often. It matches a very Quebec reality: a main living area, with an open-concept living room and kitchen heated by electric baseboard heaters, where the homeowner wants both summer cooling and a real reduction in their winter bill. The \u003cstrong\u003eKINGHOME Polaris R32 | 12,000 BTU Ductless Heat Pump\u003c\/strong\u003e is designed for this scenario.\u003c\/p\u003e\n\u003cp\u003eIts published ratings are \u003cstrong\u003e25.5 SEER2\u003c\/strong\u003e for cooling and \u003cstrong\u003e10 HSPF2\u003c\/strong\u003e for heating, with an \u003cstrong\u003eEER2 of 14.5\u003c\/strong\u003e. It is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified with the \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e, and it appears on Hydro-Québec's list with a \u003cstrong\u003e$1,800 LogisVert rebate\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhy 12,000 BTU instead of 9,000 or 18,000\u003c\/h3\u003e\n\u003cp\u003eThe difference between these three sizes is not based solely on floor area. It also depends on air volume, the number of openings between rooms, and the amount of glazing.\u003c\/p\u003e\n\u003cp\u003eA 12,000 BTU unit typically serves an open area of 400 to 650 square feet, or a large room with an opening toward a hallway. Its modulation range is \u003cstrong\u003e2,730 to 17,060 BTU\/h\u003c\/strong\u003e: it covers both the shoulder season, when the unit runs at minimum output, and a 32 °C heatwave day with full late-afternoon sun.\u003c\/p\u003e\n\u003cp\u003eThe typical case where we recommend the 18,000 BTU model instead is a completely open ground floor with a central staircase. The unit would then have to supply two partially connected levels, which exceeds what a 12,000 BTU unit can handle properly.\u003c\/p\u003e\n\u003ch3\u003eHow modulation changes a winter heating bill\u003c\/h3\u003e\n\u003cp\u003eAn electric baseboard heater converts one kilowatt-hour of electricity into one kilowatt-hour of heat. Its efficiency is always 1, regardless of the outdoor temperature. A heat pump moves heat instead of producing it, allowing it to exceed that ratio.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eCOP\u003c\/strong\u003e measures this ratio. On this model, it is \u003cstrong\u003e1.8 at -15 °C\u003c\/strong\u003e: even in the middle of a bitter cold spell, the unit supplies nearly twice as much heat as a baseboard heater using the same amount of electricity. In milder conditions, between 0 and 8 °C - that is, during the majority of heating hours in a year in \u003cstrong\u003eMontreal\u003c\/strong\u003e - the difference is even greater.\u003c\/p\u003e\n\u003cp\u003eThis is why we rarely recommend removing the baseboard heaters. The right strategy is to let the heat pump provide comfort in the main living area for most of the season, while keeping the baseboard heaters as backup in closed bedrooms and during periods of extreme cold.\u003c\/p\u003e\n\u003ch3\u003eKey heating figures\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCapacity at \u003cstrong\u003e8 °C\u003c\/strong\u003e: 12,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eCapacity at \u003cstrong\u003e-8 °C\u003c\/strong\u003e: \u003cstrong\u003e15,000 BTU\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCapacity at \u003cstrong\u003e-15 °C\u003c\/strong\u003e: 13,700 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating operating range: down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eCooling range: up to \u003cstrong\u003e50 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe capacity at -8 °C exceeds the rated capacity. This is not a typo: it is the normal behaviour of an inverter compressor, which modulates down when the weather is mild and increases its output as demand rises. Hydro-Québec also publishes this same value of 15,000 BTU\/h at -8 °C in its search tool.\u003c\/p\u003e\n\u003ch3\u003eThe $1,800 LogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThis model appears on the list of equipment eligible for Hydro-Québec's \u003cstrong\u003eLogisVert\u003c\/strong\u003e program, with assistance of \u003cstrong\u003e$1,800\u003c\/strong\u003e for homeowners in existing homes. A separate financing bonus is available for multi-unit residential buildings.\u003c\/p\u003e\n\u003cp\u003eThree practical points. The amount depends on the installation date and the list in effect at that time. The number identifying the unit in the program is \u003cstrong\u003eENERGY STAR ID 4617797\u003c\/strong\u003e, supported by \u003cstrong\u003eAHRI 218451122\u003c\/strong\u003e. The application also requires complete documentation: a detailed invoice, indoor and outdoor model numbers, and proof of payment. We provide these items as soon as the work is completed.\u003c\/p\u003e\n\u003ch2\u003eInstalling a ductless unit in a condo or plex: the real constraints\u003c\/h2\u003e\n\u003cp\u003eThe 12,000 BTU model is the size we install most often in condominiums. It is also the one where building constraints have the greatest impact.\u003c\/p\u003e\n\u003ch3\u003eThe wall, facade, and condo association\u003c\/h3\u003e\n\u003cp\u003eBefore discussing the unit, you need to know where the outdoor unit can be placed. Many condo associations prohibit installations visible from the street, and some boroughs of \u003cstrong\u003eMontreal\u003c\/strong\u003e regulate facade-mounted equipment. A backyard, side wall, or balcony may work, provided clearances are respected and hot air is not directed toward a neighbouring window.\u003c\/p\u003e\n\u003cp\u003eThe outdoor unit for this model measures \u003cstrong\u003e34.4 x 14.8 x 21.8 inches\u003c\/strong\u003e and weighs \u003cstrong\u003e81.6 pounds\u003c\/strong\u003e, providing some flexibility. It is rated at \u003cstrong\u003e55 dB(A)\u003c\/strong\u003e: this should be checked when the closest neighbour is three metres away.\u003c\/p\u003e\n\u003ch3\u003eLine-set length\u003c\/h3\u003e\n\u003cp\u003eThe refrigerant line is \u003cstrong\u003e1\/4 and 1\/2 inch\u003c\/strong\u003e, precharged for \u003cstrong\u003e25 feet\u003c\/strong\u003e and permitted up to \u003cstrong\u003e131 feet\u003c\/strong\u003e, with an additional 0.2 ounces of refrigerant per extra foot. This allowance makes it possible to route around an entire building when the only acceptable location for the outdoor unit is opposite the living room. The lines must be protected, insulated along their entire length, and secured to withstand freeze-thaw cycles.\u003c\/p\u003e\n\u003ch3\u003eElectrical supply\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e208-230 V single-phase\u003c\/strong\u003e power supply, \u003cstrong\u003e13 A MCA\u003c\/strong\u003e, \u003cstrong\u003e15 A maximum protection\u003c\/strong\u003e. A dedicated 15 A circuit is sufficient, which often avoids panel work. In older buildings where the electrical service is already heavily loaded, this modest requirement can sometimes make the difference between a feasible project and one requiring a complete upgrade.\u003c\/p\u003e\n\u003ch3\u003eEveryday comfort\u003c\/h3\u003e\n\u003cp\u003eThe indoor unit measures \u003cstrong\u003e35.6 x 8.2 x 10.9 inches\u003c\/strong\u003e and operates between \u003cstrong\u003e27 and 47 dB(A)\u003c\/strong\u003e, with an airflow of \u003cstrong\u003e182 to 424 CFM\u003c\/strong\u003e. It removes up to \u003cstrong\u003e1.4 litres of moisture per hour\u003c\/strong\u003e, a figure that matters in basements and ground-floor homes where summer humidity is the real problem, even before temperature becomes an issue.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWi-Fi is built in\u003c\/strong\u003e, with no additional module required: the unit is controlled through an app. The \u003cstrong\u003e3D airflow\u003c\/strong\u003e sweeps both vertically and horizontally, Turbo mode quickly corrects a temperature difference, and the automatic cleaning function dries the coil after a cooling cycle to help limit odours.\u003c\/p\u003e\n\u003ch3\u003eMaintenance in three steps\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eClean the filters every month\u003c\/strong\u003e during periods of intensive use. A clogged filter reduces airflow, and therefore capacity and efficiency.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeep the outdoor unit clear\u003c\/strong\u003e: snow, ice, leaves, and patio furniture. Air must circulate freely at both the front and back.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the condensate drainage\u003c\/strong\u003e before every summer. A clogged drain always reveals itself at the worst possible time.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eAnnual \u003cstrong\u003eHVAC maintenance\u003c\/strong\u003e by a refrigeration technician completes these tasks: pressure measurements, charge verification, coil cleaning, and inspection of electrical connections.\u003c\/p\u003e\n\u003ch3\u003eWho this size is for - and who it is not for\u003c\/h3\u003e\n\u003cp\u003eThe 12,000 BTU model is the right choice for a medium-sized open area, a condo, a plex unit, a partially divided ground floor, or a large primary bedroom with a home office area. It is less suitable for a small enclosed room, where the 9,000 BTU model dehumidifies better, and for a completely open ground floor spanning two levels, where the 18,000 BTU model is the appropriate choice.\u003c\/p\u003e\n\u003ch3\u003eWarranty and support\u003c\/h3\u003e\n\u003cp\u003eKinghome covers the \u003cstrong\u003ecompressor and parts for 12 years\u003c\/strong\u003e in residential applications on registered models, and for 5 or 7 years in commercial applications. We handle the registration because an unregistered warranty is worthless when you need it.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, our assessment considers the building: insulation, orientation, glazing, ceiling height, airflow, electrical capacity, and outdoor-unit location. Our refrigeration technicians are employees, we carry \u003cstrong\u003e$5,000,000\u003c\/strong\u003e in liability insurance, and we serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eMontérégie\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the KINGHOME Polaris R32 | 12,000 BTU Ductless Heat Pump. We will confirm your eligibility for LogisVert, assess your installation constraints, and provide you with a detailed quote.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Kinghome","offers":[{"title":"Default Title","offer_id":56293988663588,"sku":"KWP12R32C3O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_THERMOPOMPE_MURALE_KINGHOME_POLARIS_R32_12000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_1da5b2b1-2b1e-4a16-a607-07d7176793d4.png?v=1789509651"},{"product_id":"thermopompe-murale-kinghome-polaris-r32-18000-btu","title":"KINGHOME Polaris R32 Wall-Mounted Heat Pump | 18000 BTU","description":"\u003ch2\u003eWhen One Head Has to Handle an Entire Main Floor\u003c\/h2\u003e\n\u003cp\u003eThe move from 12,000 to 18,000 BTU marks a change in scope, not just size. At this capacity, the unit no longer serves a single room: it serves an entire living space, often open-plan and sometimes spread across partial levels. The \u003cstrong\u003eKINGHOME Polaris R32 | 18,000 BTU Wall-Mounted Heat Pump\u003c\/strong\u003e is designed precisely for this type of project, and its success depends as much on the chosen location as on the unit's specifications.\u003c\/p\u003e\n\u003cp\u003eIt offers \u003cstrong\u003e24.5 SEER2\u003c\/strong\u003e, \u003cstrong\u003e9.5 HSPF2\u003c\/strong\u003e, and an \u003cstrong\u003eEER2 of 13.65\u003c\/strong\u003e. It is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified with the \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e and qualifies for a \u003cstrong\u003e$2,448 LogisVert rebate\u003c\/strong\u003e according to Hydro-Québec's list.\u003c\/p\u003e\n\u003ch3\u003eWhat 18,000 BTU Can and Cannot Do\u003c\/h3\u003e\n\u003cp\u003eThe nominal cooling capacity is \u003cstrong\u003e18,000 BTU\/h\u003c\/strong\u003e, modulating from \u003cstrong\u003e5,118 to 22,178 BTU\/h\u003c\/strong\u003e. One point deserves attention: this model's minimum output, approximately 5,100 BTU\/h, is considerably higher than that of the 9,000 BTU model, which drops below 2,800 BTU\/h.\u003c\/p\u003e\n\u003cp\u003eThis difference explains why an 18,000 BTU unit installed in an overly small space is often disappointing. Even at its lowest setting, it delivers more capacity than a closed room requires. The result is a unit that reaches the setpoint too quickly, removes little humidity, and alternates between short operating cycles. Capacity is not a free reserve: it must match an actual demand.\u003c\/p\u003e\n\u003cp\u003eThe configurations where this size performs at its best include the open main floor of a bungalow, a 700- to 1,000-square-foot living room-kitchen-dining area, a large loft, a light commercial space such as a hair salon or small office, or a fully finished basement.\u003c\/p\u003e\n\u003ch3\u003eAir Distribution Determines the Result\u003c\/h3\u003e\n\u003cp\u003eIn a large room, the problem is almost never capacity. It is the path of the air. A properly sized unit that is poorly positioned creates a very comfortable zone within the first six feet while leaving the other end of the room unchanged.\u003c\/p\u003e\n\u003cp\u003eAirflow ranges from \u003cstrong\u003e282 to 618 CFM\u003c\/strong\u003e, providing enough output to cross a large space, provided nothing blocks the air stream. Before choosing the installation location, we look at the direction of the corridor, the position of the staircase, the height of the kitchen cabinets, the openings to adjoining rooms, and the areas where occupants actually spend their time. A kitchen island, exposed beam, or mezzanine can completely change the calculation.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e3D airflow\u003c\/strong\u003e sweeps horizontally and vertically, which is highly useful in an open-plan area. However, it cannot compensate for a poorly chosen wall.\u003c\/p\u003e\n\u003ch3\u003e20,400 BTU at -8 °C: The Number That Matters in January\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeating capacity at \u003cstrong\u003e8 °C\u003c\/strong\u003e: 18,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating capacity at \u003cstrong\u003e-8 °C\u003c\/strong\u003e: \u003cstrong\u003e20,400 BTU\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHeating capacity at \u003cstrong\u003e-15 °C\u003c\/strong\u003e: 16,500 BTU\/h, COP of 1.8\u003c\/li\u003e\n\u003cli\u003eHeating operation down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese figures show that at -8 °C, a common January temperature in \u003cstrong\u003eLaval\u003c\/strong\u003e or on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, the unit still delivers more than its nominal capacity. At -15 °C, it maintains 16,500 BTU\/h. For a well-insulated main floor, this covers a large portion of the heating load, with the existing system taking over during the coldest peaks.\u003c\/p\u003e\n\u003cp\u003eWe recommend keeping a backup heat source. Even a cold-climate wall-mounted heat pump heats the space where it is located: closed bedrooms upstairs or at the end of a corridor still have their own heating needs.\u003c\/p\u003e\n\u003ch3\u003eNoise Levels Increase with Capacity\u003c\/h3\u003e\n\u003cp\u003eThe indoor unit operates between \u003cstrong\u003e34 and 53 dB(A)\u003c\/strong\u003e. That is more than the 9,000 BTU model, which drops to 20 dB(A), and it makes sense: a fan moving 618 CFM cannot be as quiet as one moving 353.\u003c\/p\u003e\n\u003cp\u003eThis figure should be considered when choosing the location. In an open space adjoining a home office or a bedroom without a door, it is worth positioning the unit away from the work or sleeping area. At low speed, the unit remains discreet; in Turbo mode, it can be heard.\u003c\/p\u003e\n\u003ch2\u003eElectrical Requirements, Clearances, and Snow: The Three Factors That Determine the Project\u003c\/h2\u003e\n\u003cp\u003eStarting at 18,000 BTU, the technical requirements become fundamental to the project. They must be checked before signing, not afterward.\u003c\/p\u003e\n\u003ch3\u003eA 20 A Circuit\u003c\/h3\u003e\n\u003cp\u003eThe outdoor unit requires a \u003cstrong\u003e208-230 V single-phase\u003c\/strong\u003e power supply, with a \u003cstrong\u003eminimum circuit ampacity of 16 A\u003c\/strong\u003e and a \u003cstrong\u003emaximum protection of 20 A\u003c\/strong\u003e. Moving from 15 to 20 A has practical consequences: a larger cable gauge, a dedicated breaker, and, above all, available space in the electrical panel.\u003c\/p\u003e\n\u003cp\u003eIn duplexes and triplexes in central \u003cstrong\u003eMontreal\u003c\/strong\u003e neighbourhoods, already crowded 100 A panels are common. We check the remaining capacity before confirming the price, because an electrical upgrade discovered on the morning of installation can turn a simple project into a construction job.\u003c\/p\u003e\n\u003ch3\u003eSnow, Defrosting, and Support Height\u003c\/h3\u003e\n\u003cp\u003eThe outdoor unit measures \u003cstrong\u003e37.7 x 15.8 x 26.0 inches\u003c\/strong\u003e and weighs \u003cstrong\u003e94.8 pounds\u003c\/strong\u003e. Taller and heavier than smaller models, it requires a support sized accordingly.\u003c\/p\u003e\n\u003cp\u003eIn heating mode, the unit produces defrost water. This water must drain away from the base. A unit installed too close to the ground accumulates ice underneath it, winter after winter, until the fan is blocked. We favour a sturdy wall bracket or an elevated ground stand, selected according to local snow accumulation rather than a standard height.\u003c\/p\u003e\n\u003cp\u003eThe roof's snow-shedding path must also be considered. A unit installed below a roof slope without a snow guard will eventually be damaged: it is one of the most common repairs we see on installations completed by others.\u003c\/p\u003e\n\u003ch3\u003eRefrigerant Charge and Piping\u003c\/h3\u003e\n\u003cp\u003eThis model contains \u003cstrong\u003e54.7 ounces of R-32\u003c\/strong\u003e, considerably more than the 38.1 ounces in the 9,000 and 12,000 BTU models. The piping remains \u003cstrong\u003e1\/4 and 1\/2 inch\u003c\/strong\u003e, precharged for \u003cstrong\u003e25 feet\u003c\/strong\u003e and permitted up to \u003cstrong\u003e131 feet\u003c\/strong\u003e, with an additional 0.2 ounces per foot beyond that length.\u003c\/p\u003e\n\u003cp\u003eA larger refrigerant charge makes connection quality even more important. Properly made flares, a vacuum process completed fully rather than cut short, a leak test, and complete insulation of both lines: these are the invisible steps that determine whether the unit will deliver on its promises five years from now.\u003c\/p\u003e\n\u003ch3\u003e$2,448 LogisVert Rebate\u003c\/h3\u003e\n\u003cp\u003eThis model is listed under the \u003cstrong\u003eLogisVert\u003c\/strong\u003e program with assistance of \u003cstrong\u003e$2,448\u003c\/strong\u003e for an owner of an existing home, under \u003cstrong\u003eENERGY STAR ID 4663287\u003c\/strong\u003e and \u003cstrong\u003eAHRI 218640147\u003c\/strong\u003e. A separate financing bonus applies to multi-unit residential buildings.\u003c\/p\u003e\n\u003cp\u003eThe amount depends on the list in effect on the installation date. We verify eligibility when preparing the quote and provide the complete documentation at the end of the work.\u003c\/p\u003e\n\u003ch3\u003eFive Mistakes to Avoid at This Capacity\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eChoosing 18,000 BTU for a closed room.\u003c\/strong\u003e The excessively high minimum output compromises dehumidification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalling it facing an obstacle.\u003c\/strong\u003e Tall cabinets, beams, or a mezzanine: the air stream needs a clear path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUnderestimating the electrical panel.\u003c\/strong\u003e A 20 A circuit requires space and suitable cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstalling the outdoor unit too low.\u003c\/strong\u003e Defrost ice accumulates and blocks the fan.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNeglecting the condensate drain.\u003c\/strong\u003e With up to 1.8 litres of moisture removed per hour, an improperly sloped drain will cause problems quickly.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eWarranty and Service\u003c\/h3\u003e\n\u003cp\u003eKinghome covers the \u003cstrong\u003ecompressor and parts for 12 years\u003c\/strong\u003e in residential applications on registered models, and for 5 or 7 years in commercial applications. We complete the registration as part of the installation.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, evaluating a project of this size includes checking the electrical panel, analysing air distribution, selecting the outdoor support based on snow and wind exposure, routing the lines, and managing condensate. Our refrigeration technicians are employees, our liability insurance is \u003cstrong\u003e$5,000,000\u003c\/strong\u003e, and we serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, \u003cstrong\u003eMontérégie\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the KINGHOME Polaris R32 | 18,000 BTU Wall-Mounted Heat Pump. We will assess your space, check your electrical capacity, and recommend the location that will provide the best comfort.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Kinghome","offers":[{"title":"Default Title","offer_id":56293988761892,"sku":"KWP18R32C3O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_THERMOPOMPE_MURALE_KINGHOME_POLARIS_R32_18000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_ac00ff87-5e63-4a4a-9dbe-7395c76fefe5.png?v=1789509699"},{"product_id":"thermopompe-murale-kinghome-polaris-r32-24000-btu","title":"KINGHOME Polaris R32 Wall-Mounted Heat Pump | 24000 BTU","description":"\u003ch2\u003eThe largest size in the series, and the only one reaching 26,000 BTU in heating\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eKINGHOME Polaris R32 | 24,000 BTU Wall-Mounted Heat Pump\u003c\/strong\u003e is designed for spaces where a wall-mounted unit must do the work of a complete system: a large open-plan ground floor, a loft, a light commercial space, a living area with a cathedral ceiling, or a space that two smaller units would have covered less effectively. It is also the model in the series offering the highest cold-weather heating capacity, with a \u003cstrong\u003eCOP of 1.95 at -15 °C\u003c\/strong\u003e, higher than that of the other three sizes.\u003c\/p\u003e\n\u003cp\u003eIts ratings are \u003cstrong\u003e25 SEER2\u003c\/strong\u003e, \u003cstrong\u003e9.5 HSPF2\u003c\/strong\u003e, and \u003cstrong\u003e14.2 EER2\u003c\/strong\u003e. It is \u003cstrong\u003eENERGY STAR\u003c\/strong\u003e certified with the \u003cstrong\u003ecold-climate designation\u003c\/strong\u003e, and qualifies for a \u003cstrong\u003e$3,120 LogisVert rebate\u003c\/strong\u003e, the highest in the POLARIS range.\u003c\/p\u003e\n\u003ch3\u003e22,000 or 24,000 BTU? The two figures explained\u003c\/h3\u003e\n\u003cp\u003eThis model is sold as a 24,000 BTU unit, and its technical data sheet indicates a cooling capacity of \u003cstrong\u003e22,000 BTU\/h\u003c\/strong\u003e under standardized test conditions. Both figures are accurate, and it is worth understanding why before comparing quotes.\u003c\/p\u003e\n\u003cp\u003eThe 24,000 refers to the commercial designation for the size, which places the unit within a product range. The 22,000 is the capacity measured at 95 °F according to the test method. This is the second figure Hydro-Québec displays in its search tool under the heading nominal capacity.\u003c\/p\u003e\n\u003cp\u003eIn heating mode, the capacity reaches \u003cstrong\u003e24,000 BTU\/h at 8 °C\u003c\/strong\u003e. A buyer who compares only the cooling figure may therefore assume the unit is weaker than it really is. We prefer to explain this distinction in advance rather than have a customer discover it on a technical data sheet after signing.\u003c\/p\u003e\n\u003ch3\u003eThe widest modulation range in the series\u003c\/h3\u003e\n\u003cp\u003eIn cooling mode, the unit modulates from \u003cstrong\u003e3,410 to 28,660 BTU\/h\u003c\/strong\u003e. This range is remarkable for a wall-mounted unit of this size: the minimum output drops lower than that of the 18,000 BTU model, while the maximum output is significantly higher.\u003c\/p\u003e\n\u003cp\u003eFor the occupant, this means a unit that maintains a stable temperature during the shoulder seasons without constantly shutting off, while retaining enough capacity for a heatwave in a room with extensive glazing. The airflow follows the same principle, ranging from \u003cstrong\u003e383 to 736 CFM\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e26,000 BTU at -8 °C\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeating capacity at \u003cstrong\u003e8 °C\u003c\/strong\u003e: 24,000 BTU\/h\u003c\/li\u003e\n\u003cli\u003eHeating capacity at \u003cstrong\u003e-8 °C\u003c\/strong\u003e: \u003cstrong\u003e26,000 BTU\/h\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHeating capacity at \u003cstrong\u003e-15 °C\u003c\/strong\u003e: 20,400 BTU\/h, COP of \u003cstrong\u003e1.95\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eHeating operation down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis is the highest heating capacity we offer on a single-zone wall-mounted unit in the KINGHOME catalogue. At -8 °C, the unit delivers 26,000 BTU\/h: enough to cover the full load of a well-insulated ground floor measuring several hundred square feet, without supplemental heat, during most of the winter.\u003c\/p\u003e\n\u003cp\u003eA COP of 1.95 at -15 °C means that even in this cold, each kilowatt-hour consumed produces nearly two kilowatt-hours of heat. Compared with an electric baseboard heater, whose ratio remains fixed at 1, the difference is directly reflected on the bill.\u003c\/p\u003e\n\u003ch3\u003eA 5\/8-inch gas line and an additional charge of 0.4 ounces per foot\u003c\/h3\u003e\n\u003cp\u003eThis size differs from the other three in its piping: \u003cstrong\u003e1\/4 inch for the liquid line and 5\/8 inch for the gas line\u003c\/strong\u003e, compared with 1\/2 inch on the smaller sizes. The higher refrigerant flow requires a larger diameter.\u003c\/p\u003e\n\u003cp\u003eThere are two practical consequences. First, the equipment is not interchangeable with that of an 18,000 BTU model: an existing 1\/2-inch line left in place during a replacement is not suitable. Second, the additional charge is \u003cstrong\u003e0.4 ounces per foot\u003c\/strong\u003e beyond the \u003cstrong\u003e25 precharged feet\u003c\/strong\u003e, twice that of the other models. On a 60-foot run, this represents an amount of refrigerant that must be weighed, not estimated. The factory charge is \u003cstrong\u003e52.9 ounces of R-32\u003c\/strong\u003e, and the allowable line length is up to \u003cstrong\u003e131 feet\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eA 24,000 BTU project must be prepared before purchase\u003c\/h2\u003e\n\u003cp\u003eAt this size, three checks determine whether the project is simple or complex. They are carried out on-site before the quote.\u003c\/p\u003e\n\u003ch3\u003eA 30 A circuit\u003c\/h3\u003e\n\u003cp\u003eThe power supply is \u003cstrong\u003e208-230 V single-phase\u003c\/strong\u003e, with a \u003cstrong\u003eminimum circuit ampacity of 22 A\u003c\/strong\u003e and a \u003cstrong\u003emaximum protection of 30 A\u003c\/strong\u003e. This is the highest requirement in the POLARIS series, and it often changes the nature of the project.\u003c\/p\u003e\n\u003cp\u003eA dedicated 30 A breaker requires appropriately sized wiring and available space in the electrical panel. In a 1960s home still equipped with a 100 A service, with an electric water heater, stove, and dryer, the remaining capacity must be calculated. We perform this check before confirming a price, because discovering the issue on installation day delays the entire project.\u003c\/p\u003e\n\u003ch3\u003eA 44-inch indoor unit\u003c\/h3\u003e\n\u003cp\u003eThe indoor unit measures \u003cstrong\u003e43.9 x 9.8 x 13.1 inches\u003c\/strong\u003e. It is significantly longer than those of the other sizes, and the chosen wall must accommodate it without making the room feel visually cramped or blocking the airflow.\u003c\/p\u003e\n\u003cp\u003eThere must be clearance on both sides, open space above, and nothing obstructing the air outlet below. A nearby door frame, a tall bookcase, or a wall corner that is too narrow are real constraints for this size. The outdoor unit measures \u003cstrong\u003e37.7 x 15.8 x 26.0 inches\u003c\/strong\u003e, weighs \u003cstrong\u003e92.6 pounds\u003c\/strong\u003e, and requires an elevated support designed according to the area's snow accumulation.\u003c\/p\u003e\n\u003ch3\u003eTwo litres of moisture per hour\u003c\/h3\u003e\n\u003cp\u003eDehumidification reaches \u003cstrong\u003e2 litres per hour\u003c\/strong\u003e, the highest in the series. This is a real advantage in large ground-floor or basement spaces where summer discomfort comes as much from humidity as from temperature.\u003c\/p\u003e\n\u003cp\u003eIn return, this requires a properly designed condensate drain. Two litres per hour at peak is a volume that leaves no room for an insufficient slope or a pinched pipe behind a wall. We check drainage at startup and recommend inspecting the drain before each cooling season.\u003c\/p\u003e\n\u003ch3\u003e$3,120 LogisVert rebate\u003c\/h3\u003e\n\u003cp\u003eThis model is listed in the \u003cstrong\u003eLogisVert\u003c\/strong\u003e program with assistance of \u003cstrong\u003e$3,120\u003c\/strong\u003e for an existing-home owner, under \u003cstrong\u003eENERGY STAR ID 4663298\u003c\/strong\u003e and \u003cstrong\u003eAHRI 218640282\u003c\/strong\u003e. A separate financing bonus applies to multi-unit buildings, making this size interesting for plex owners equipping several units.\u003c\/p\u003e\n\u003cp\u003eThe amount corresponds to the list in effect on the installation date. We verify eligibility when preparing the quote and provide the complete documentation at the end of the work: detailed invoice, indoor and outdoor model numbers, and certification references.\u003c\/p\u003e\n\u003ch3\u003eLight commercial use\u003c\/h3\u003e\n\u003cp\u003eThis size is often chosen for commercial spaces: retail stores, offices, waiting rooms, and heated workshops. The manufacturer's warranty distinguishes between the two applications. In residential use, it covers \u003cstrong\u003ethe compressor and parts for 12 years\u003c\/strong\u003e on registered models. In commercial applications, it is \u003cstrong\u003e5 or 7 years\u003c\/strong\u003e depending on the conditions. A property owner equipping a rental commercial space should understand this distinction before purchasing.\u003c\/p\u003e\n\u003ch3\u003eThe most costly mistakes with this size\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eReusing an existing 1\/2-inch refrigerant line.\u003c\/strong\u003e This model requires a 5\/8-inch gas line.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEstimating the additional charge instead of weighing it.\u003c\/strong\u003e At 0.4 ounces per foot, errors accumulate quickly and affect performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfirming the project without checking the electrical panel.\u003c\/strong\u003e A 30 A circuit is not always available.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChoosing a wall that is too narrow.\u003c\/strong\u003e The indoor unit is nearly 44 inches long and must remain unobstructed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTreating the drain as an afterthought.\u003c\/strong\u003e At 2 litres per hour, it is the main source of preventable water damage.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eWhy entrust this project to AirGreen\u003c\/h3\u003e\n\u003cp\u003eA unit of this capacity exposes every installation shortcut within a few months. Our refrigeration technicians are employees, flaring, vacuum evacuation, and charge weighing are performed according to industry standards, and warranty registration is included. We carry \u003cstrong\u003e$5,000,000\u003c\/strong\u003e in liability insurance and serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, \u003cstrong\u003eMontérégie\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free estimate for the KINGHOME Polaris R32 | 24,000 BTU Wall-Mounted Heat Pump. We will measure your space, check your electrical capacity, confirm the applicable rebate, and provide you with a complete quote.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Kinghome","offers":[{"title":"Default Title","offer_id":56293988827428,"sku":"KWP24R32C3O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_THERMOPOMPE_MURALE_KINGHOME_POLARIS_R32_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_da9e0a73-29b2-46fa-8537-5ce2a7424477.png?v=1789509699"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/collections\/00_THERMOPOMPE_MURALE_KINGHOME_POLARIS_R32_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_da9e0a73-29b2-46fa-8537-5ce2a7424477.png?v=1790264200","url":"https:\/\/airgreen.ca\/en\/collections\/thermopompe-murale-kinghome-polaris-r32-montreal-laval-rive-sud-nord.oembed","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}