{"title":"NOVAIR Wall-Mounted Heat Pump","description":null,"products":[{"product_id":"thermopompe-climatiseur-mural-novair-ultra-heat-25-c-9-000-btu","title":"NOVAIR Ultra Heat Wall-Mounted Heat Pump\/Air Conditioner (-25°C) | 9,000 BTU","description":"\u003ch2\u003eUltra Heat 9,000 BTU: for a bedroom or an office, a COP of 2.80 at −8 °C\u003c\/h2\u003e\u003cp\u003eThe 9,000 is the smallest of the four Ultra Heat sizes we carry, and the only one of the four with ENERGY STAR cold-climate certification. Its NEEP listing shows a COP of 2.80 at −8 °C, the best of the four. It is meant for one room: a bedroom, a home office, a small room where the door usually stays shut.\u003c\/p\u003e\u003ch3\u003eAt night, in the bedroom\u003c\/h3\u003e\u003cp\u003eNOVAIR’s brochure rates the indoor unit at 40 dB(A) on high, 34 dB(A) on medium and 23.5 dB(A) on low, the lowest of our four Ultra Heat sizes. It does not say how these were measured.\u003c\/p\u003e\u003cp\u003eThe outdoor unit is rated at 53 dB(A). The brochure does not say at what distance or under what conditions this figure is measured; what you hear depends on where the unit goes, and we choose the wall with you during the on-site assessment.\u003c\/p\u003e\u003cp\u003eAs a reference point for the head, Québec.ca’s page on noise measurement describes 40 dB(A) as a place perceived as peaceful and 50 dB(A) as the point where disturbance begins. On high, the indoor unit sits right at that first mark; on low for the night, it stays well below it.\u003c\/p\u003e\u003ch3\u003eIn deep cold\u003c\/h3\u003e\u003cp\u003eListed on NEEP for AHRI 211709677 (record dated November 20, 2026), as a share of the 9,000 BTU\/h nominal capacity:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003e8 °C (47 °F):\u003c\/strong\u003e 10,000 BTU\/h, 111% of nominal, COP 3.96.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003e−8 °C (17 °F):\u003c\/strong\u003e 8,500 BTU\/h, 94%, COP 2.80.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003e−15 °C (5 °F):\u003c\/strong\u003e 7,500 BTU\/h, 83%, COP 2.18.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eA COP of 2.80 means that at −8 °C, every kWh the unit draws comes back as 2.8 kWh of heat; a baseboard heater gives back exactly what it draws. Over a full season, its HSPF2 is 12.3 in region IV and 9.2 in region V.\u003c\/p\u003e\u003cp\u003eIn mild weather, at 8 °C, the unit throttles down to 3,565 BTU\/h, which helps it start and stop less often in a small room, and its listed maximum is 13,241 BTU\/h, 47% above nominal, enough to warm up a room that has gone cold.\u003c\/p\u003e\u003cp\u003eNEEP lists nothing below −15 °C. According to NOVAIR’s brochure, the Ultra Heat series heats down to −25 °C: that is an operating limit, not a capacity. Output already dips below nominal at −8 °C, and the coldest nights are when the room loses the most heat. For a room over a garage or with two outside walls, also look at the \u003ca href=\"\/en\/collections\/novair-climatisation-ventilation-chauffage-montreal-laval-longueuil-rive-sud-et-rive-nord\"\u003eHyper Heat 9,000\u003c\/a\u003e, which delivers more heat at −15 °C.\u003c\/p\u003e\u003ch3\u003eSummer, door closed\u003c\/h3\u003e\u003cp\u003eFor cooling, NEEP lists a SEER2 of 25.5 and an EER2 of 15. SEER2 is the average efficiency over a cooling season; EER2 is the efficiency at 35 °C (95 °F). At that temperature the nominal capacity is 9,000 BTU\/h and the listed maximum is 12,402 BTU\/h, enough to quickly cool an overheated bedroom.\u003c\/p\u003e\u003ch3\u003eFrom the bedroom to the outside wall\u003c\/h3\u003e\u003cp\u003eThese figures come from the \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/NOVAIR_ULTRA_HEAT_THERMOPOMPE_-_BROCHURE_EN.pdf\"\u003eNOVAIR Ultra Heat brochure\u003c\/a\u003e. The two units are joined by a 1\/4 in and 3\/8 in line set and a 14 AWG × 4 communication wire. The line can run at most 82 ft (25 m), with a maximum height difference of 33 ft (10 m) between the units: enough for an upstairs bedroom with the outdoor unit on the ground.\u003c\/p\u003e\u003cp\u003ePower is 208\/230 V, single-phase, 60 Hz. The brochure gives two current ratings: “Minimum Ampacity” at 13 A, then a second row, also labelled “MCA”, at 15 A.\u003c\/p\u003e\u003cp\u003eThe indoor unit measures 31.57 × 7.87 × 11.61 in. The outdoor unit measures 30.12 × 11.93 × 21.85 in and weighs 63.71 lb net, which is what its wall bracket or base has to carry. AirGreen confirms where both units go, the line route and the electrical circuit during the free on-site assessment of heating needs.\u003c\/p\u003e\u003ch3\u003eLogisVert: not eligible\u003c\/h3\u003e\u003cp\u003eThis model is not eligible for Hydro-Québec’s LogisVert program, whose guide requires an outdoor unit rated at least 12,000 BTU\/h in nominal cooling; this one is 9,000. Keep the AHRI number above and ENERGY STAR ID 2448756 on file anyway.\u003c\/p\u003e\u003cp\u003eThe 12,000 BTU and larger Ultra Heat sizes each show an indicative LogisVert amount on their own page. Only Hydro-Québec confirms the assistance granted. Going bigger just to qualify makes sense only if the room needs the heat, and the on-site assessment is where we find out. The program is explained on our \u003ca href=\"\/en\/pages\/subventions-3-0\"\u003egrants page\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eWi-Fi and warranty\u003c\/h3\u003e\u003cp\u003eThe NOVAIR brochures say “Wifi Ready”: the unit is ready for Wi-Fi. Your quote spells out what is included for your installation.\u003c\/p\u003e\u003cp\u003eAccording to the NOVAIR brochures, the 10-year warranty requires the unit to be registered; AirGreen takes care of the registration. The compressor, parts and labour breakdown is in the spec table on this page.\u003c\/p\u003e\u003ch3\u003eWith AirGreen\u003c\/h3\u003e\u003cp\u003eWe start with a free on-site assessment, then give you a firm written quote before any work begins. The installation is done by our refrigeration mechanics under AirGreen’s RBQ licence 5645-9605-01 (15.8 ventilation, 15.10 refrigeration, 16 electrical), in Montreal, Laval, Longueuil, the South Shore and the North Shore.\u003c\/p\u003e\u003cp\u003eTo book an assessment, call \u003ca href=\"tel:+15143162973\"\u003e514 316-2973\u003c\/a\u003e or write to \u003ca href=\"mailto:sales@airgreen.ca\"\u003esales@airgreen.ca\u003c\/a\u003e. The other Ultra Heat sizes and the Hyper Heat series are on our \u003ca href=\"\/en\/collections\/novair-climatisation-ventilation-chauffage-montreal-laval-longueuil-rive-sud-et-rive-nord\"\u003eNOVAIR page\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eSold and installed by AirGreen\u003c\/p\u003e","brand":"Novair","offers":[{"title":"Default Title","offer_id":51391824199972,"sku":"LEA09SZ25SK-O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/thermopompe-climatiseur-mural-novair-ultra-heat-9000-btu-airgreen.png?v=1768432211"},{"product_id":"thermopompe-climatiseur-mural-novair-ultra-heat-25-c-12-000-btu","title":"NOVAIR Ultra Heat Wall-Mounted Heat Pump\/Air Conditioner (-25°C) | 12,000 BTU","description":"\u003ch2\u003eNOVAIR Ultra Heat 12,000: 2.39 kWh of heat per kWh at −15 °C\u003c\/h2\u003e\u003cp\u003eThat 2.39 is the COP NEEP lists for this Ultra Heat at −15 °C, the highest of the eight NOVAIR wall units we offer; our other three Ultra Heat sizes sit between 1.80 and 2.18. It suits the living room of a condo or the main room of a duplex or triplex unit, where efficiency counts for more than peak output.\u003c\/p\u003e\u003ch3\u003eWhat NEEP lists for winter\u003c\/h3\u003e\u003cp\u003eThese figures are listed on NEEP under AHRI number 211709678 (record dated November 20, 2026). At 8 °C (47 °F), the unit delivers 12,000 BTU\/h, 100% of its nominal capacity, at a COP of 3.70. At −8 °C (17 °F), it delivers 9,000 BTU\/h, or 75%, at a COP of 2.69. At −15 °C (5 °F), it still puts out 8,000 BTU\/h, or 67%, at a COP of 2.39.\u003c\/p\u003e\u003cp\u003eCOP is the heat you get back for each kilowatt-hour of electricity: 3.70 at 8 °C, still 2.39 at −15 °C. The NEEP record stops at −15 °C. According to the NOVAIR brochure, the Ultra Heat series heats down to −25 °C. That is its operating limit, not a capacity figure.\u003c\/p\u003e\u003ch3\u003eIt slows down before it shuts off\u003c\/h3\u003e\u003cp\u003eThe compressor varies its output. At −15 °C, NEEP lists a minimum of 2,305 BTU\/h, so when the living room needs little heat, the unit can run slowly, and it starts and stops less often.\u003c\/p\u003e\u003cp\u003eAt the top end, the limit is just as clear: at −15 °C, the listed maximum is also 8,000 BTU\/h. If you need the full 12,000 BTU\/h at −15 °C, the Hyper Heat 12,000 is listed on NEEP at that figure, with a lower COP of 1.80. You can compare the two on our \u003ca href=\"\/en\/collections\/novair-climatisation-ventilation-chauffage-montreal-laval-longueuil-rive-sud-et-rive-nord\"\u003eNOVAIR page\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eLogisVert and the cold-climate designation\u003c\/h3\u003e\u003cp\u003eThis model is ENERGY STAR certified, but not for cold climates. For LogisVert, Hydro-Québec’s program, that shows in the rate applied to capacity at −8 °C: $120 per 1,000 BTU\/h with the cold-climate designation, $50 without it. Indicative LogisVert amount: $450, from 9,000 BTU\/h at −8 °C × $50 per 1,000 BTU\/h. Only Hydro-Québec confirms the assistance granted. For your application, keep the AHRI number above and ENERGY STAR ID 2448759. The program is summarized on our \u003ca href=\"\/en\/pages\/subventions-3-0\"\u003egrants page\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eCooling: SEER2 24.6, EER2 13.7\u003c\/h3\u003e\u003cp\u003eNEEP lists a SEER2 of 24.6 and an EER2 of 13.7, with 12,000 BTU\/h at 35 °C (95 °F). SEER2 sums up efficiency over the season; EER2 measures it at the 35 °C test point, a heat-wave day.\u003c\/p\u003e\u003ch3\u003eWhat the head and the outdoor unit sound like\u003c\/h3\u003e\u003cp\u003eAccording to the NOVAIR brochure, the wall head is rated at 42, 36 and 25 dB(A) on high, medium and low; the brochure does not state the test conditions.\u003c\/p\u003e\u003cp\u003eThe outdoor unit is rated at 53.5 dB(A). The brochure does not say at what distance or under what conditions this figure is measured; what you hear depends on where the unit goes, and we choose the wall with you during the on-site assessment.\u003c\/p\u003e\u003cp\u003eFor the head, Québec.ca’s “Mesure du bruit” page associates 40 dB(A) with a place perceived as peaceful and 50 dB(A) with the onset of disturbance. On low, the head stays well under the first mark; on high, it goes slightly over.\u003c\/p\u003e\u003ch3\u003eInstalling it in a condo or a plex\u003c\/h3\u003e\u003cp\u003eAccording to the \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/NOVAIR_ULTRA_HEAT_THERMOPOMPE_-_BROCHURE_EN.pdf\"\u003eUltra Heat brochure\u003c\/a\u003e, this size uses a 1\/4 in and 1\/2 in line set, no more than 82 ft (25 m) of line and 33 ft (10 m) of height difference between the two units, and a 14 AWG × 4 communication wire. It runs on 208\/230 V, single-phase, 60 Hz. The brochure lists “Minimum Ampacity” at 13 A, then a second row, also labelled “MCA”, at 15 A.\u003c\/p\u003e\u003cp\u003eThe indoor unit measures 31.57 × 7.87 × 11.61 in. The outdoor unit measures 30.12 × 11.93 × 21.85 in and weighs 63.71 lb net, which is the load on the wall bracket or ground base. We confirm where both units go, the line route and the circuit during the on-site assessment of heating needs.\u003c\/p\u003e\u003ch3\u003eWi-Fi and warranty\u003c\/h3\u003e\u003cp\u003eThe NOVAIR brochures say “Wifi Ready”: the unit is ready for Wi-Fi. Your quote spells out what is included for your installation.\u003c\/p\u003e\u003cp\u003eAccording to the NOVAIR brochures, the 10-year warranty requires the unit to be registered; AirGreen takes care of the registration. The compressor, parts and labour breakdown is in the spec table on this page.\u003c\/p\u003e\u003ch3\u003eWith AirGreen\u003c\/h3\u003e\u003cp\u003eThe on-site assessment is free, and you get a firm written quote before any work begins. The installation is done by our refrigeration mechanics, under AirGreen’s RBQ licence 5645-9605-01 (subclasses 15.8 ventilation, 15.10 refrigeration and 16 electrical), in Montreal, Laval, Longueuil, the South Shore and the North Shore.\u003c\/p\u003e\u003cp\u003eTo book the visit, call \u003ca href=\"tel:+15143162973\"\u003e514 316-2973\u003c\/a\u003e, write to \u003ca href=\"mailto:sales@airgreen.ca\"\u003esales@airgreen.ca\u003c\/a\u003e or use our \u003ca href=\"\/en\/pages\/contactez-nous\"\u003econtact page\u003c\/a\u003e. You will find the other Ultra Heat sizes, and the Hyper Heat series, on our \u003ca href=\"\/en\/collections\/novair-climatisation-ventilation-chauffage-montreal-laval-longueuil-rive-sud-et-rive-nord\"\u003eNOVAIR page\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eSold and installed by AirGreen\u003c\/p\u003e","brand":"Novair","offers":[{"title":"Default Title","offer_id":51391824232740,"sku":"LEA12SZ25SK-O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/thermopompe-climatiseur-mural-novair-ultra-heat-12000btu-airgreen.png?v=1768432196"},{"product_id":"thermopompe-climatiseur-mural-novair-ultra-heat-25-c-18-000-btu","title":"NOVAIR Ultra Heat Wall-Mounted Heat Pump\/Air Conditioner (-25°C) | 18,000 BTU","description":"\u003ch2\u003eNOVAIR Ultra Heat 18,000: 24.5 dB(A) on low speed, for an open-concept main floor\u003c\/h2\u003e\u003cp\u003eNOVAIR’s Ultra Heat brochure lists 24.5 dB(A) on low speed for this head, which is 42.6 inches wide. That is one decibel more than the Ultra Heat 9,000, whose head is 31.57 inches wide. This 18,000 BTU unit is meant for an open-concept main floor, where the kitchen, dining room and living room are one space and a single head has to fade into the background in the evening.\u003c\/p\u003e\u003ch3\u003eThe head, speed by speed\u003c\/h3\u003e\u003cp\u003eAccording to the \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/NOVAIR_ULTRA_HEAT_THERMOPOMPE_-_BROCHURE_EN.pdf\"\u003eNOVAIR Ultra Heat brochure\u003c\/a\u003e, the indoor head is rated at 45.5, 41 and 24.5 dB(A) on high, medium and low. The brochure does not give the test conditions, so use these figures to compare units, not to predict what you will hear in your living room.\u003c\/p\u003e\u003cp\u003eThe outdoor unit is rated at 58 dB(A). The brochure does not say at what distance or under what conditions this figure is measured; what you hear depends on where the unit goes, and we choose the wall with you during the on-site assessment.\u003c\/p\u003e\u003cp\u003eAs a reference for the head, Québec.ca’s “Mesure du bruit” page associates 40 dB(A) with a place perceived as peaceful and 50 dB(A) with the onset of disturbance. On low, the head stays well below the first mark; on high, it sits between the two.\u003c\/p\u003e\u003ch3\u003e98 ft of line set, 66 ft of height difference\u003c\/h3\u003e\u003cp\u003eThe brochure allows a maximum of 98 ft (29.9 m) of line set and 66 ft (20.1 m) of height difference between the two units, against 82 ft and 33 ft for the 9,000 and 12,000 in the series. That lets the head go on the best wall of the open floor, even when the outdoor unit stays at the back or side of the house.\u003c\/p\u003e\u003cp\u003eWhat the brochure calls for:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e1\/4 in and 1\/2 in refrigerant lines, plus 14 AWG × 4 communication wire between the two units;\u003c\/li\u003e\u003cli\u003e208\/230 V, single-phase, 60 Hz power. The brochure lists “Minimum Ampacity” at 17 A, then a second row, also labelled “MCA”, at 25 A;\u003c\/li\u003e\u003cli\u003ean indoor head measuring 42.6 × 9.21 × 13.27 in;\u003c\/li\u003e\u003cli\u003ean outdoor unit measuring 34.04 × 13.46 × 26.50 in and weighing 95.02 lb net, a load carried by the wall bracket or the ground base.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eDuring the free assessment of heating needs, we confirm the dimensions on site, along with both unit locations, the line route and the circuit.\u003c\/p\u003e\u003ch3\u003eIn deep cold: 63% of its nominal capacity at −15 °C\u003c\/h3\u003e\u003cp\u003eThe heating figures are listed on NEEP under AHRI certificate 211709679 (record dated November 20, 2026). At 8 °C (47 °F), the unit delivers 19,000 BTU\/h, 106% of its 18,000 BTU\/h nominal capacity, at a COP of 3.35. At −8 °C (17 °F), it delivers 14,900 BTU\/h (83%) at a COP of 2.48. At −15 °C (5 °F), 11,300 BTU\/h remain (63%), at a COP of 2.02.\u003c\/p\u003e\u003cp\u003eCOP compares the heat delivered with the electricity used: at −15 °C, every kWh you pay for comes back as 2.02 kWh of heat. Over a full heating season, its HSPF2 is 10.8 in Region IV and 7.8 in Region V. NEEP publishes no data point below −15 °C. According to the NOVAIR brochure, the Ultra Heat series heats down to −25 °C; that is an operating limit, not a capacity.\u003c\/p\u003e\u003cp\u003eThat 63% defines its role. It belongs in a house that keeps its baseboards or another heat source for the coldest nights. If the open floor has to run on the heat pump alone in deep cold, the Hyper Heat 18,000 lists 18,000 BTU\/h at the same point; both series are on our \u003ca href=\"\/en\/collections\/novair-climatisation-ventilation-chauffage-montreal-laval-longueuil-rive-sud-et-rive-nord\"\u003eNOVAIR page\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eSummer, at 35 °C outside\u003c\/h3\u003e\u003cp\u003eAt 35 °C (95 °F), NEEP lists a rated cooling capacity of 18,000 BTU\/h. SEER2, which measures cooling efficiency over a season, is 23.5; EER2, measured at 35 °C, is 12.5. On high speed, the head moves 530 cfm according to the brochure, which matters when cool air has to reach the far end of a large room.\u003c\/p\u003e\u003ch3\u003eLogisVert: indicative amount of $745\u003c\/h3\u003e\u003cp\u003eThe Ultra Heat 18,000 is ENERGY STAR certified, but not in the cold-climate category, so Hydro-Québec’s LogisVert program applies its lower rate. Indicative LogisVert amount: $745, which is $50 per 1,000 BTU\/h on its −8 °C capacity of 14,900 BTU\/h. Only Hydro-Québec confirms the assistance granted.\u003c\/p\u003e\u003cp\u003eTwo numbers to keep for your file: the AHRI number above and ENERGY STAR ID 2448760. Program details are on our \u003ca href=\"\/en\/pages\/subventions-3-0\"\u003egrants page\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eWi-Fi and warranty\u003c\/h3\u003e\u003cp\u003eThe NOVAIR brochures say “Wifi Ready”: the unit is ready for Wi-Fi. Your quote spells out what is included for your installation.\u003c\/p\u003e\u003cp\u003eAccording to the NOVAIR brochures, the 10-year warranty requires the unit to be registered; AirGreen takes care of the registration. The compressor, parts and labour breakdown is in the spec table on this page.\u003c\/p\u003e\u003ch3\u003eWorking with AirGreen\u003c\/h3\u003e\u003cp\u003eThe on-site assessment of heating needs is free, and you get a firm written quote before any work starts. Our refrigeration mechanics do the installation under AirGreen’s RBQ licence 5645-9605-01 (15.8 ventilation, 15.10 refrigeration, 16 electrical) in Montreal, Laval, Longueuil, the South Shore and the North Shore.\u003c\/p\u003e\u003cp\u003eTo book the assessment, call \u003ca href=\"tel:+15143162973\"\u003e514 316-2973\u003c\/a\u003e or write to \u003ca href=\"mailto:sales@airgreen.ca\"\u003esales@airgreen.ca\u003c\/a\u003e. The other Ultra Heat sizes and the Hyper Heat series are on our \u003ca href=\"\/en\/collections\/novair-climatisation-ventilation-chauffage-montreal-laval-longueuil-rive-sud-et-rive-nord\"\u003eNOVAIR page\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eSold and installed by AirGreen\u003c\/p\u003e","brand":"Novair","offers":[{"title":"Default Title","offer_id":51391824298276,"sku":"LEA18SZ25SK-O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/thermopompe-climatiseur-mural-novair-ultra-heat-18000-btu-montreal.png?v=1768432168"},{"product_id":"thermopompe-climatiseur-mural-novair-ultra-heat-25-c-24-000-btu","title":"NOVAIR Ultra Heat Wall-Mounted Heat Pump\/Air Conditioner (-25°C) | 24,000 BTU","description":"\u003ch2\u003eNOVAIR Ultra Heat 24,000 BTU: a 164-foot line set, the longest of our Ultra Heat units\u003c\/h2\u003e\u003cp\u003eThis is the largest of the four Ultra Heat sizes we carry, and the only one of the four whose refrigerant line can run 164 ft, with 82 ft of height difference between the head and the outdoor unit. It suits a large open area, especially when the outdoor unit has to sit far away: at the back of the yard, on the roof, on the other side of the building. According to the NOVAIR brochure, it is also the only one of the four with a dual rotary compressor.\u003c\/p\u003e\u003ch3\u003ePlanning a long line set\u003c\/h3\u003e\u003cp\u003eFrom the 24,000 row of the \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/NOVAIR_ULTRA_HEAT_THERMOPOMPE_-_BROCHURE_EN.pdf\"\u003eNOVAIR Ultra Heat brochure\u003c\/a\u003e:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003eLine set:\u003c\/strong\u003e 3\/8 in and 5\/8 in, the largest diameters of our four Ultra Heat sizes.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eLength and height:\u003c\/strong\u003e 164 ft (50 m) of line and 82 ft (25 m) of height difference at most.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eCommunication wire:\u003c\/strong\u003e 14 AWG × 4.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003ePower:\u003c\/strong\u003e 208\/230 V, single-phase, 60 Hz. The brochure lists “Minimum Ampacity”, 22 A, then a second row, also labelled “MCA”, 30 A.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e 42.64 × 9.61 × 13.27 in for the head, 37.24 × 16.14 × 31.89 in for the outdoor unit.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 124.78 lb net for the outdoor unit, the load the wall bracket or ground base has to carry.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eAirGreen confirms where both units go, the line route and the circuit during the free on-site assessment of heating needs.\u003c\/p\u003e\u003ch3\u003eFrom mild days to deep cold: the NEEP figures\u003c\/h3\u003e\u003cp\u003eThe heating figures are listed on NEEP under AHRI certificate 211709680 (record dated November 20, 2026). At 8 °C (47 °F), the heat pump delivers 25,000 BTU\/h, 104% of its nominal capacity, at a COP of 3.76. At −8 °C (17 °F), it drops to 16,200 BTU\/h (67.5%) at a COP of 2.40. At −15 °C (5 °F), it delivers 15,500 BTU\/h (65%) at a COP of 1.80, with a listed maximum of 17,500 BTU\/h.\u003c\/p\u003e\u003cp\u003eOn mild days, it will not go below 7,885 BTU\/h at 8 °C. In a closed room it would start and stop more often, so this size belongs in a large open space.\u003c\/p\u003e\u003cp\u003eA COP of 1.80 means every kilowatt-hour you pay for turns into 1.8 kWh of heat, while an electric baseboard gives back exactly what it draws. That said, it is the lowest COP at −15 °C of our four Ultra Heat sizes; the other three are listed between 2.02 and 2.39.\u003c\/p\u003e\u003cp\u003eNEEP publishes no point below −15 °C. The −25 °C that the NOVAIR brochure gives for the Ultra Heat series is the lowest outdoor temperature at which the unit keeps running, not a published capacity. If the heat pump has to heat on its own on the coldest nights, look at the Hyper Heat 24,000 on the \u003ca href=\"\/en\/collections\/novair-climatisation-ventilation-chauffage-montreal-laval-longueuil-rive-sud-et-rive-nord\"\u003eNOVAIR page\u003c\/a\u003e instead: NEEP lists it at 25,000 BTU\/h at −15 °C.\u003c\/p\u003e\u003ch3\u003eIn summer\u003c\/h3\u003e\u003cp\u003eFor cooling, NEEP lists 24,000 BTU\/h at 35 °C (95 °F), a SEER2 of 22 and an EER2 of 14. SEER2 is the average efficiency over a whole season; EER2 is the efficiency at 35 °C outdoors. On both, it does a little better than the Hyper Heat 24,000 (SEER2 21.5, EER2 13), which matters if you are buying mainly for summer.\u003c\/p\u003e\u003ch3\u003eThe sound of a large unit\u003c\/h3\u003e\u003cp\u003eAccording to the NOVAIR brochure, the head is rated at 48, 40 and 28 dB(A) on high, medium and low. Test conditions are not given.\u003c\/p\u003e\u003cp\u003eThe outdoor unit is rated at 60 dB(A). The brochure does not say at what distance or under what conditions this figure is measured; what you hear depends on where the unit goes, and we choose the wall with you during the on-site assessment. The 164 ft of line gives that choice some room.\u003c\/p\u003e\u003cp\u003eFor the head, Québec.ca’s noise scale (“Mesure du bruit”) links 40 dB(A) to a place perceived as peaceful and 50 dB(A) to the onset of disturbance. Low speed stays well under the first mark and high speed under the second.\u003c\/p\u003e\u003ch3\u003eLogisVert: the amount for this size\u003c\/h3\u003e\u003cp\u003eHydro-Québec’s LogisVert program starts from heating capacity at −8 °C. This heat pump is ENERGY STAR certified, but not for cold climates, so it falls under the $50 per 1,000 BTU\/h rate. Indicative LogisVert amount: $810 (16,200 BTU\/h × $50 \/ 1,000). Only Hydro-Québec confirms the assistance granted.\u003c\/p\u003e\u003cp\u003eFor your application, keep the AHRI number above and ENERGY STAR ID 2448761. For comparison, the Hyper Heat 24,000, certified for cold climates, has an indicative amount of $2,544. The program’s conditions are on our \u003ca href=\"\/en\/pages\/subventions-3-0\"\u003egrants page\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eWi-Fi and warranty\u003c\/h3\u003e\u003cp\u003eThe NOVAIR brochures say “Wifi Ready”: the unit is ready for Wi-Fi. Your quote spells out what is included for your installation.\u003c\/p\u003e\u003cp\u003eAccording to the NOVAIR brochures, the 10-year warranty requires the unit to be registered; AirGreen takes care of the registration. The compressor, parts and labour breakdown is in the spec table on this page.\u003c\/p\u003e\u003ch3\u003eWith AirGreen\u003c\/h3\u003e\u003cp\u003eThe on-site assessment is free, and you get a firm written quote before any work starts. Our refrigeration mechanics install under AirGreen’s RBQ licence 5645-9605-01 (15.8 ventilation, 15.10 refrigeration, 16 electrical) in Montreal, Laval, Longueuil, the South Shore and the North Shore.\u003c\/p\u003e\u003cp\u003eTo book the assessment: \u003ca href=\"tel:+15143162973\"\u003e514 316-2973\u003c\/a\u003e or \u003ca href=\"mailto:sales@airgreen.ca\"\u003esales@airgreen.ca\u003c\/a\u003e. You will find the other Ultra Heat sizes, and the Hyper Heat series, on the \u003ca href=\"\/en\/collections\/novair-climatisation-ventilation-chauffage-montreal-laval-longueuil-rive-sud-et-rive-nord\"\u003eNOVAIR page\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eSold and installed by AirGreen\u003c\/p\u003e","brand":"Novair","offers":[{"title":"Default Title","offer_id":51391824363812,"sku":"LEA24SZ25SK-O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/novair-ultra-heat-24000-btu-wall-mounted-thermopump-air-conditioner.png?v=1768432082"},{"product_id":"thermopompe-air-climatise-mural-novair-hyper-heat-35-c-9-000-btu","title":"NOVAIR Hyper Heat Wall-Mounted Air Conditioning Heat Pump (-35°C) | 9,000 BTU","description":"\u003ch2\u003eHyper Heat 9,000 BTU: at −15 °C, more heat than its nominal rating\u003c\/h2\u003e\u003cp\u003eAt −15 °C, NEEP lists this Hyper Heat at 10,600 BTU\/h, 118% of its 9,000 BTU nominal capacity. In summer, its SEER2 of 28.1 is the highest of the eight NOVAIR wall units we carry. It is built for the room that never stays comfortable: the room over the garage, the addition, the finished attic that freezes in January and bakes in July.\u003c\/p\u003e\u003ch3\u003eFrom 8 to −15 °C, according to NEEP\u003c\/h3\u003e\u003cp\u003eThese heating figures are listed on NEEP for AHRI 211709682 (record dated November 20, 2026). At 8 °C (47 °F) the unit delivers 12,000 BTU\/h, 133% of nominal, at a COP of 3.78. At −8 °C (17 °F) the listing shows 9,500 BTU\/h (106%) and a COP of 2.53; at −15 °C (5 °F), 10,600 BTU\/h (118%) and a COP of 2.00.\u003c\/p\u003e\u003cp\u003eSo the capacity listed at −8 °C is lower than at −15 °C. That is how NEEP lists it, and we show it as is. The one safe takeaway: at both temperatures, the listed output is above nominal.\u003c\/p\u003e\u003cp\u003eA COP of 2.00 at −15 °C means each kWh the unit draws becomes 2 kWh of heat; a baseboard heater only gives back what it draws. Below −15 °C, NEEP lists nothing. NOVAIR’s brochure says the Hyper Heat series heats down to −35 °C: that is an operating limit, not a capacity.\u003c\/p\u003e\u003ch3\u003eThe highest SEER2 of the eight\u003c\/h3\u003e\u003cp\u003eFor cooling, NEEP lists this 9,000 at a SEER2 of 28.1 and an EER2 of 16.2, also the highest of the eight. SEER2 covers a whole cooling season; EER2 is a single point, a 35 °C (95 °F) heat-wave day. At that temperature the nominal capacity is 9,000 BTU\/h and the listed maximum is 14,398 BTU\/h, 60% above nominal.\u003c\/p\u003e\u003ch3\u003eHyper Heat or Ultra Heat, same size\u003c\/h3\u003e\u003cp\u003eNOVAIR also makes an \u003ca href=\"\/en\/collections\/novair-climatisation-ventilation-chauffage-montreal-laval-longueuil-rive-sud-et-rive-nord\"\u003eUltra Heat 9,000\u003c\/a\u003e. In deep cold its NEEP listing shows a better COP than this Hyper Heat’s, but less heat at −15 °C. In mild weather, too, the Ultra Heat has the edge: at 8 °C the Hyper Heat does not throttle below 5,070 BTU\/h, so in a well-insulated room it is likely to start and stop more often. Pick the Hyper Heat for a room that loses a lot of heat; for an ordinary room, the Ultra Heat holds its own.\u003c\/p\u003e\u003ch3\u003eBefore we drill through the wall\u003c\/h3\u003e\u003cp\u003eAccording to the \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/NOVAIR_HYPER_HEAT_THERMOPOMPE_-_BROCHURE_EN.pdf\"\u003eNOVAIR Hyper Heat brochure\u003c\/a\u003e, the two units are connected by a 1\/4 in and 3\/8 in line set and a 14 AWG × 4 communication wire. The line can run at most 82 ft (25 m), and the height difference between the units is limited to 33 ft (10 m).\u003c\/p\u003e\u003cp\u003eThe unit runs on 208\/230 V, single-phase, 60 Hz. The brochure lists “Minimum Ampacity” at 15 A, then a second row, also labelled “MCA”, at 15 A as well. The compressor is a dual rotary.\u003c\/p\u003e\u003cp\u003eThe indoor unit measures 33.40 × 9.18 × 11.76 in. The outdoor unit measures 31.69 × 12.99 × 21.81 in and weighs 74.07 lb net, a load to plan for on the wall bracket or base. We confirm where both units go, the line route and the circuit during the free on-site assessment of heating needs.\u003c\/p\u003e\u003ch3\u003eSound, inside and out\u003c\/h3\u003e\u003cp\u003eNOVAIR’s brochure puts the indoor unit at 40 dB(A) on high, 35 dB(A) on medium and 23.5 dB(A) on low. Test conditions are not given.\u003c\/p\u003e\u003cp\u003eThe outdoor unit is rated at 54.5 dB(A). The brochure does not say at what distance or under what conditions this figure is measured; what you hear depends on where the unit goes, and we choose the wall with you during the on-site assessment.\u003c\/p\u003e\u003cp\u003eAs a yardstick for the head, Québec.ca’s page on noise measurement ties 40 dB(A) to a place perceived as peaceful and 50 dB(A) to the onset of disturbance. Inside, even high speed stays at the peaceful level.\u003c\/p\u003e\u003ch3\u003eWhy LogisVert does not apply\u003c\/h3\u003e\u003cp\u003eThis Hyper Heat 9,000 is not eligible for Hydro-Québec’s LogisVert program. The program guide requires an outdoor unit of at least 12,000 BTU\/h nominal cooling capacity; this one is 9,000. Its 10,600 BTU\/h at −15 °C does not change that, because the rule looks at nominal cooling. Still, keep the AHRI number above and ENERGY STAR ID 2450095 with your house papers. Our \u003ca href=\"\/en\/pages\/subventions-3-0\"\u003egrants page\u003c\/a\u003e sums up how the program works.\u003c\/p\u003e\u003ch3\u003eWarranty and Wi-Fi\u003c\/h3\u003e\u003cp\u003eAccording to the NOVAIR brochures, the 10-year warranty requires the unit to be registered; AirGreen takes care of the registration. The compressor, parts and labour breakdown is in the spec table on this page.\u003c\/p\u003e\u003cp\u003eThe NOVAIR brochures say “Wifi Ready”: the unit is ready for Wi-Fi. Your quote spells out what is included for your installation.\u003c\/p\u003e\u003ch3\u003eWho does the work\u003c\/h3\u003e\u003cp\u003eOur refrigeration mechanics work under AirGreen’s RBQ licence 5645-9605-01 (15.8 ventilation, 15.10 refrigeration, 16 electrical), in Montreal, Laval, Longueuil, the South Shore and the North Shore. Before any work there is a free on-site assessment of heating needs, then a firm written quote.\u003c\/p\u003e\u003cp\u003eReach us at \u003ca href=\"tel:+15143162973\"\u003e514 316-2973\u003c\/a\u003e, at \u003ca href=\"mailto:sales@airgreen.ca\"\u003esales@airgreen.ca\u003c\/a\u003e or through our \u003ca href=\"\/en\/pages\/contactez-nous\"\u003econtact form\u003c\/a\u003e. The other Hyper Heat sizes and the Ultra Heat series are on our \u003ca href=\"\/en\/collections\/novair-climatisation-ventilation-chauffage-montreal-laval-longueuil-rive-sud-et-rive-nord\"\u003eNOVAIR page\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eSold and installed by AirGreen\u003c\/p\u003e","brand":"Novair","offers":[{"title":"Default Title","offer_id":51391824396580,"sku":"LEA09SZ35SK-O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/novair_thermopompe_air_climatise_mural_hyper_heat_9000_btu_confort_quatre_saisons_energy_star.png?v=1768431998"},{"product_id":"thermopompe-air-climatise-mural-novair-hyper-heat-35-c-12-000-btu","title":"NOVAIR Hyper Heat Wall-Mounted Air Conditioning Heat Pump (-35°C) | 12,000 BTU","description":"\u003ch2\u003eNOVAIR Hyper Heat 12,000: 12,000 BTU\/h at 8 °C and at −15 °C\u003c\/h2\u003e\u003cp\u003eOn its NEEP record, this Hyper Heat delivers 12,000 BTU\/h at 8 °C, on a fall day, and the same at −15 °C, on a January night: 100% of its nominal capacity both times. It is the 12,000 to choose for one large room, a family room for instance, that needs 12,000 BTU\/h even at −15 °C.\u003c\/p\u003e\u003ch3\u003eNEEP’s figures for this 12,000\u003c\/h3\u003e\u003cp\u003eFigures listed on NEEP under AHRI number 211709683 (record dated November 20, 2026). At 8 °C (47 °F): 12,000 BTU\/h, 100% of nominal, at a COP of 3.86. At −15 °C (5 °F): still 12,000 BTU\/h and 100%, at a COP of 1.80. In between, at −8 °C (17 °F), the record shows 10,000 BTU\/h, or 83%, at a COP of 2.40; more on that below.\u003c\/p\u003e\u003cp\u003eWhat drops with the cold is efficiency. A COP of 1.80 means that at −15 °C, each kilowatt-hour you pay Hydro-Québec for turns into 1.80 kWh of heat in the room; at 8 °C, the same kilowatt-hour gave 3.86. NEEP lists no point below −15 °C; according to the NOVAIR brochure, the Hyper Heat series keeps heating down to −35 °C, which is an operating limit rather than a capacity.\u003c\/p\u003e\u003ch3\u003eThe −8 °C figure, as NEEP shows it\u003c\/h3\u003e\u003cp\u003eThe record shows less heat at −8 °C (10,000 BTU\/h) than at −15 °C (12,000). That is how NEEP lists it, and we report it as is. The same record gives a maximum of 13,112 BTU\/h at −8 °C, so the 10,000 is the rated value at that test point, not a ceiling. Yet it is the one the LogisVert calculation uses.\u003c\/p\u003e\u003ch3\u003eWhich wall for the outdoor unit\u003c\/h3\u003e\u003cp\u003eAccording to the NOVAIR brochure, the outdoor unit is rated at 56 dB(A), the highest of the four 9,000 and 12,000 BTU NOVAIR wall units we carry. The brochure does not say at what distance or under what conditions this figure is measured; what you hear depends on where the unit goes, and we choose the wall with you during the on-site assessment. A kitchen or garage wall beats a bedroom wall, and that includes the neighbours’ bedrooms. Whichever wall you pick has to stay within the 82 ft (25 m) line limit.\u003c\/p\u003e\u003cp\u003eInside, the same brochure lists 41.5 dB(A) on high, 36 dB(A) on medium and 24 dB(A) on low, again without test conditions. On low and medium, the wall head stays under the 40 dB(A) that Québec.ca associates with a place perceived as peaceful.\u003c\/p\u003e\u003ch3\u003eThe brochure’s installation figures\u003c\/h3\u003e\u003cp\u003eThe \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/NOVAIR_HYPER_HEAT_THERMOPOMPE_-_BROCHURE_EN.pdf\"\u003eHyper Heat brochure\u003c\/a\u003e lists, for this size, a 1\/4 in and 1\/2 in line set, a maximum line length of 82 ft (25 m) and a maximum height difference of 33 ft (10 m) between the units, plus a 14 AWG × 4 communication wire. It needs a 208\/230 V single-phase, 60 Hz supply. The brochure lists 15 A under “Minimum Ampacity” and 15 A again on a second row, also labelled “MCA”.\u003c\/p\u003e\u003cp\u003eDimensions: 33.40 × 9.18 × 11.76 in for the indoor unit, 31.69 × 12.99 × 21.81 in for the outdoor unit. The outdoor unit weighs 73.63 lb net, which is what the wall bracket or ground base will carry. During the on-site assessment of heating needs, we confirm with you where both units go, the line route and the circuit.\u003c\/p\u003e\u003ch3\u003eLogisVert is worked out from 10,000 BTU\/h\u003c\/h3\u003e\u003cp\u003eThis Hyper Heat is ENERGY STAR certified for cold climates. Indicative LogisVert amount: $1,200, worked out from its rated capacity at −8 °C rather than at −15 °C: 10,000 BTU\/h × $120 per 1,000 BTU\/h, the rate Hydro-Québec’s program applies to ENERGY STAR cold-climate units. Only Hydro-Québec confirms the assistance granted. Keep the AHRI number above and ENERGY STAR ID 2448785 for your application. The program conditions are summarized on our \u003ca href=\"\/en\/pages\/subventions-3-0\"\u003egrants page\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eCooling: 12,000 BTU\/h at 35 °C\u003c\/h3\u003e\u003cp\u003eNEEP lists a SEER2 of 25.5 and an EER2 of 14, with 12,000 BTU\/h at 35 °C (95 °F). The first number covers the whole summer, the second a single 35 °C day.\u003c\/p\u003e\u003ch3\u003eWi-Fi and warranty\u003c\/h3\u003e\u003cp\u003eThe NOVAIR brochures say “Wifi Ready”: the unit is ready for Wi-Fi. Your quote spells out what is included for your installation.\u003c\/p\u003e\u003cp\u003eAccording to the NOVAIR brochures, the 10-year warranty requires the unit to be registered; AirGreen takes care of the registration. The compressor, parts and labour breakdown is in the spec table on this page.\u003c\/p\u003e\u003ch3\u003eWith AirGreen\u003c\/h3\u003e\u003cp\u003eWe start by coming to your home for the on-site assessment, at no charge; a firm written quote follows before any work. The installation is handled by our refrigeration mechanics, under AirGreen’s RBQ licence 5645-9605-01 (subclasses 15.8 ventilation, 15.10 refrigeration and 16 electrical). We install in Montreal, Laval, Longueuil, the South Shore and the North Shore.\u003c\/p\u003e\u003cp\u003eReach us at \u003ca href=\"tel:+15143162973\"\u003e514 316-2973\u003c\/a\u003e or \u003ca href=\"mailto:sales@airgreen.ca\"\u003esales@airgreen.ca\u003c\/a\u003e, or through our \u003ca href=\"\/en\/pages\/contactez-nous\"\u003econtact page\u003c\/a\u003e. To compare with the other sizes in both series, see the \u003ca href=\"\/en\/collections\/novair-climatisation-ventilation-chauffage-montreal-laval-longueuil-rive-sud-et-rive-nord\"\u003eNOVAIR page\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eSold and installed by AirGreen\u003c\/p\u003e","brand":"Novair","offers":[{"title":"Default Title","offer_id":51391824429348,"sku":"LEA12SZ35SK-O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/novair_thermopompe_air_climatise_mural_hyper_heat_12000_btu_energy_star_montral.png?v=1768431977"},{"product_id":"thermopompe-air-climatise-mural-novair-hyper-heat-35-c-18-000-btu","title":"NOVAIR Hyper Heat Wall-Mounted Air Conditioning Heat Pump (-35°C) | 18,000 BTU","description":"\u003ch2\u003eNOVAIR Hyper Heat 18,000: still a full 18,000 BTU\/h at −15 °C\u003c\/h2\u003e\u003cp\u003eFor a floor the heat pump has to carry almost on its own in January: at −15 °C, NEEP still lists 18,000 BTU\/h, its full nominal capacity.\u003c\/p\u003e\u003ch3\u003eThree NEEP points, from mild weather to deep cold\u003c\/h3\u003e\u003cp\u003eListed on NEEP under AHRI certificate 211709684, record dated November 20, 2026:\u003c\/p\u003e\u003cul\u003e\u003cli\u003e8 °C (47 °F): 18,000 BTU\/h, 100% of nominal, COP 3.10;\u003c\/li\u003e\u003cli\u003e−8 °C (17 °F): 15,000 BTU\/h, 83%, COP 2.35;\u003c\/li\u003e\u003cli\u003e−15 °C (5 °F): 18,000 BTU\/h, 100%, COP 1.80.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eThe −8 °C figure is lower than the −15 °C one, and that is how NEEP lists it, next to a maximum capacity of 19,200 BTU\/h at −8 °C. NEEP publishes nothing below −15 °C. According to the NOVAIR brochure, the Hyper Heat series heats down to −35 °C, which is an operating limit, not a capacity.\u003c\/p\u003e\u003ch3\u003eMore heat at −15 °C, at a COP of 1.80\u003c\/h3\u003e\u003cp\u003eA COP of 1.80 means each kWh of electricity becomes 1.80 kWh of heat, whereas a baseboard heater gives back exactly what it draws. At the same −15 °C, the Ultra Heat 18,000 has a better COP, 2.02, but delivers only 11,300 BTU\/h. The Hyper Heat gives you more heat for slightly less efficiency per kWh: that is the trade-off between the two 18,000 models. Over the whole season, the order flips: its HSPF2 is 11.3 in Region IV and 7.9 in Region V, against 10.8 and 7.8 for the Ultra Heat 18,000.\u003c\/p\u003e\u003cp\u003eWhether it can heat your floor on its own, without baseboards, depends on the house: insulation, windows, room volume. We check that on site, before you get a quote.\u003c\/p\u003e\u003ch3\u003eLogisVert: indicative amount of $1,800, based on 15,000 BTU\/h\u003c\/h3\u003e\u003cp\u003eIndicative LogisVert amount: $1,800. Because the Hyper Heat 18,000 is ENERGY STAR certified for cold climates, Hydro-Québec’s LogisVert program applies its higher rate, $120 per 1,000 BTU\/h, to the −8 °C capacity: 15,000 BTU\/h, not the 18,000 BTU\/h listed at −15 °C. Only Hydro-Québec confirms the assistance granted.\u003c\/p\u003e\u003cp\u003eFor your file, keep the AHRI number above and ENERGY STAR ID 2448755. The program rules are on our \u003ca href=\"\/en\/pages\/subventions-3-0\"\u003egrants page\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003e59 dB(A) outside: placement matters\u003c\/h3\u003e\u003cp\u003eAccording to the \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/NOVAIR_HYPER_HEAT_THERMOPOMPE_-_BROCHURE_EN.pdf\"\u003eNOVAIR Hyper Heat brochure\u003c\/a\u003e, the outdoor unit is rated at 59 dB(A). The brochure does not say at what distance or under what conditions this figure is measured; what you hear depends on where the unit goes, and we choose the wall with you during the on-site assessment.\u003c\/p\u003e\u003cp\u003eThe indoor head is rated at 46 dB(A) on high, 40 dB(A) on medium and 25 dB(A) on low; here too, the brochure does not state the test conditions. For the head, Québec.ca’s “Mesure du bruit” page associates 40 dB(A) with a place perceived as peaceful and 50 dB(A) with the onset of disturbance. Indoors, medium speed sits right at the first mark and low speed well under it.\u003c\/p\u003e\u003ch3\u003eWhat your home needs for the installation\u003c\/h3\u003e\u003cp\u003ePer the brochure, the two units are connected by 1\/4 in and 1\/2 in refrigerant lines and 14 AWG × 4 communication wire, over a maximum of 98 ft (29.9 m) and with no more than 66 ft (20.1 m) of height difference. Power is 208\/230 V, single-phase, 60 Hz. The brochure lists “Minimum Ampacity” at 16 A, then a second row, also labelled “MCA”, at 25 A.\u003c\/p\u003e\u003cp\u003eThe outdoor unit measures 35.04 × 13.46 × 26.50 in and weighs 100.97 lb net: that is the load on the wall bracket or ground base. The Hyper Heat brochure gives the head as 40.06 × 9.72 × 12.60 in. We confirm the dimensions on site, along with the unit locations, the line route and the electrical circuit, during the free assessment of heating needs.\u003c\/p\u003e\u003ch3\u003eSummer: SEER2 of 21.5\u003c\/h3\u003e\u003cp\u003eAt 35 °C (95 °F), NEEP lists 18,000 BTU\/h of rated cooling, with a SEER2 of 21.5 and an EER2 of 12.5. Over the cooling season, the Ultra Heat 18,000 does a little better (SEER2 23.5). You pick the Hyper Heat for winter.\u003c\/p\u003e\u003ch3\u003eWi-Fi and warranty\u003c\/h3\u003e\u003cp\u003eThe NOVAIR brochures say “Wifi Ready”: the unit is ready for Wi-Fi. Your quote spells out what is included for your installation.\u003c\/p\u003e\u003cp\u003eAccording to the NOVAIR brochures, the 10-year warranty requires the unit to be registered; AirGreen takes care of the registration. The compressor, parts and labour breakdown is in the spec table on this page.\u003c\/p\u003e\u003ch3\u003eWith AirGreen\u003c\/h3\u003e\u003cp\u003eThe first step is a free on-site assessment of heating needs. Before any work begins, you have a firm written quote in hand. Our refrigeration mechanics install under AirGreen’s RBQ licence 5645-9605-01 (15.8 ventilation, 15.10 refrigeration, 16 electrical) across Montreal, Laval, Longueuil, the South Shore and the North Shore. Reach us at \u003ca href=\"tel:+15143162973\"\u003e514 316-2973\u003c\/a\u003e or \u003ca href=\"mailto:sales@airgreen.ca\"\u003esales@airgreen.ca\u003c\/a\u003e. The other Hyper Heat sizes and the Ultra Heat series are together on our \u003ca href=\"\/en\/collections\/novair-climatisation-ventilation-chauffage-montreal-laval-longueuil-rive-sud-et-rive-nord\"\u003eNOVAIR page\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003eSold and installed by AirGreen\u003c\/p\u003e","brand":"Novair","offers":[{"title":"Default Title","offer_id":51391825051940,"sku":"LEA18SZ35SK-O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/novair_hyper_heat_thermopompe_air_climatise_mural_18000btu_quebec_hiver_-35c.png?v=1768431957"},{"product_id":"thermopompe-air-climatise-mural-novair-hyper-heat-35-c-24-000-btu","title":"NOVAIR Hyper Heat Wall-Mounted Air Conditioning Heat Pump (-35°C) | 24,000 BTU","description":"\u003ch2\u003eNOVAIR Hyper Heat 24,000 BTU: COP 2.21 at −15 °C, the best of our Hyper Heat units\u003c\/h2\u003e\u003cp\u003eIts COP of 2.21 at −15 °C is the best of the four Hyper Heat sizes we carry, and NEEP still lists 25,000 BTU\/h at that temperature, 104% of its nominal capacity. It suits a large duplex or triplex apartment, or a cottage you live in all winter, that has to stay warm once the cold sets in for good.\u003c\/p\u003e\u003ch3\u003eThree temperatures, three NEEP figures\u003c\/h3\u003e\u003cp\u003eFigures listed on NEEP under AHRI certificate 211709685 (record dated November 20, 2026):\u003c\/p\u003e\u003cul\u003e\u003cli\u003e\u003cstrong\u003e8 °C (47 °F):\u003c\/strong\u003e 29,000 BTU\/h, 121% of nominal, COP 3.40. NEEP lists a maximum of 30,995 BTU\/h.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003e−8 °C (17 °F):\u003c\/strong\u003e 21,200 BTU\/h, 88%, COP 2.88.\u003c\/li\u003e\u003cli\u003e\u003cstrong\u003e−15 °C (5 °F):\u003c\/strong\u003e 25,000 BTU\/h, 104%, COP 2.21.\u003c\/li\u003e\u003c\/ul\u003e\u003cp\u003eSo the published capacity at −8 °C is lower than at −15 °C. That is not a typo on our end: it is how the NEEP record lists it, and that −8 °C figure is the one LogisVert uses.\u003c\/p\u003e\u003cp\u003eCOP is the heat you get for the electricity you use. At 2.21, every kilowatt-hour drawn from your electrical panel gives 2.21 kWh of heat, even at −15 °C. Our other three Hyper Heat sizes are listed between 1.80 and 2.00 at that temperature.\u003c\/p\u003e\u003cp\u003eNEEP has no figure for anything colder than −15 °C. The Hyper Heat series heats down to −35 °C according to the NOVAIR brochure; take that number for what it is, the point where the unit still runs, not a measured output.\u003c\/p\u003e\u003ch3\u003eLogisVert: the math starts at −8 °C\u003c\/h3\u003e\u003cp\u003eHydro-Québec’s LogisVert program multiplies the capacity at −8 °C by a set rate per 1,000 BTU\/h. Because this model is ENERGY STAR certified for cold climates, it gets the $120 rate. Indicative LogisVert amount: $2,544 (21,200 BTU\/h × $120 \/ 1,000). Only Hydro-Québec confirms the assistance granted.\u003c\/p\u003e\u003cp\u003eThe numbers to put on your application are the AHRI certificate mentioned above and ENERGY STAR ID 2449918. How the program works is explained on our \u003ca href=\"\/en\/pages\/subventions-3-0\"\u003egrants page\u003c\/a\u003e.\u003c\/p\u003e\u003ch3\u003eBefore installation: weight, line set and circuit\u003c\/h3\u003e\u003cp\u003eAccording to the \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/NOVAIR_HYPER_HEAT_THERMOPOMPE_-_BROCHURE_EN.pdf\"\u003eNOVAIR Hyper Heat brochure\u003c\/a\u003e (PDF), the outdoor unit weighs 134.48 lb net, more than four times the head (29.98 lb). It is the heaviest outdoor unit in our NOVAIR wall lineup. All that weight sits on the wall bracket or the ground base.\u003c\/p\u003e\u003cp\u003eThe outdoor unit measures 37.24 × 16.14 × 31.89 in, and the head 46.85 × 11.2 × 14.59 in. Between them run a 3\/8 in and 5\/8 in line set, limited to 164 ft (50 m) in length and 82 ft (25 m) in height difference, and a 14 AWG × 4 communication wire.\u003c\/p\u003e\u003cp\u003ePower is 208\/230 V, single-phase, 60 Hz (the brochure prints “280\/230V” for this size, an obvious misprint). The brochure also gives two ampacity rows: “Minimum Ampacity”, 25 A, then a second row also labelled “MCA”, 35 A. AirGreen confirms where both units go, the line route and the circuit during the free on-site assessment of heating needs.\u003c\/p\u003e\u003ch3\u003eSound: what you should know\u003c\/h3\u003e\u003cp\u003eAccording to the NOVAIR brochure, the head runs at 46.5 dB(A) on high, 44 dB(A) on medium and 35 dB(A) on low. No test conditions are printed with these values. On low, 35 dB(A) is more than our other three Hyper Heat heads, which are listed between 23.5 and 25 dB(A).\u003c\/p\u003e\u003cp\u003eThe outdoor unit is rated at 62 dB(A). The brochure does not say at what distance or under what conditions this figure is measured; what you hear depends on where the unit goes, and we choose the wall with you during the on-site assessment.\u003c\/p\u003e\u003cp\u003eFor the head, Québec.ca’s noise scale (“Mesure du bruit”) associates 40 dB(A) with a place perceived as peaceful and 50 dB(A) with the onset of disturbance. Low speed stays under the first mark, while medium and high fall between the two: this is a head for a living area rather than a bedroom.\u003c\/p\u003e\u003ch3\u003eFor cooling\u003c\/h3\u003e\u003cp\u003eIn summer, NEEP lists a SEER2 of 21.5 and an EER2 of 13. SEER2 sums up a whole season; EER2 is the efficiency measured at 35 °C outdoors. You choose this model for winter first; for summer, NEEP lists its rated 24,000 BTU\/h at 35 °C (95 °F).\u003c\/p\u003e\u003ch3\u003eWi-Fi and the 10-year warranty\u003c\/h3\u003e\u003cp\u003eThe NOVAIR brochures say “Wifi Ready”: the unit is ready for Wi-Fi. Your quote spells out what is included for your installation.\u003c\/p\u003e\u003cp\u003eAccording to the NOVAIR brochures, the 10-year warranty requires the unit to be registered; AirGreen takes care of the registration. The compressor, parts and labour breakdown is in the spec table on this page.\u003c\/p\u003e\u003ch3\u003eYour project with AirGreen\u003c\/h3\u003e\u003cp\u003eAirGreen comes to you for the on-site assessment, free of charge, and gives you a firm written quote before any work begins. Our refrigeration mechanics do the installation under AirGreen’s RBQ licence 5645-9605-01 (15.8 ventilation, 15.10 refrigeration, 16 electrical) in Montreal, Laval, Longueuil, the South Shore and the North Shore.\u003c\/p\u003e\u003cp\u003eCall \u003ca href=\"tel:+15143162973\"\u003e514 316-2973\u003c\/a\u003e or email \u003ca href=\"mailto:sales@airgreen.ca\"\u003esales@airgreen.ca\u003c\/a\u003e. The \u003ca href=\"\/en\/collections\/novair-climatisation-ventilation-chauffage-montreal-laval-longueuil-rive-sud-et-rive-nord\"\u003eNOVAIR page\u003c\/a\u003e shows the other Hyper Heat sizes and the Ultra Heat series.\u003c\/p\u003e\u003cp\u003eSold and installed by AirGreen\u003c\/p\u003e","brand":"Novair","offers":[{"title":"Default Title","offer_id":51391827935524,"sku":"LEA24SZ35SK-O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/novair-thermopompe-mural-24000btu-hyper-heat-energy-efficient.png?v=1768431921"}],"url":"https:\/\/airgreen.ca\/en\/collections\/thermopompe-murale-novair.oembed","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}