{"title":"ZEPHYR Wall-Mounted Heat Pump","description":"","products":[{"product_id":"thermopompe-murale-zephyr-18-de-24-000-btu-montreal","title":"Wall Mounted Heat Pump Zephyr 18 of 24 000 BTU Montreal","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInstallation and distribution of the Zephyr 18 24,000 BTU wall-mounted heat pump, throughout Greater Montreal.\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eOur Zephyr heat pump is an inverter heat pump designed according to our specifications and fully compliant with Quebec standards.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eA high energy-efficiency inverter wall-mounted heat pump, featuring a \u003cstrong data-mce-fragment=\"1\"\u003eTOSHIBA compressor\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Zephyr heat pump’s condenser absorbs more heat during heating thanks to 2 rows of absorption surfaces compared to 1.5 in other brands.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith ultra-wide frequency control technology, the heat pump intelligently regulates the operating frequency based on temperature variations. The control is more precise and prevents fluctuations in ambient temperature, allowing you to stay comfortable.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Zephyr heat pump’s heating mode produces heat even at very low winter temperatures. Heat generation at -20°C is achieved thanks to preheating technology and electric chassis heating.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eNote that the Zephyr 17 was upgraded in 2021 to become the Zephyr 18.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":44553278882084,"sku":"ZE-24CA17","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/products\/THERMOPOMPEMURALEZEPHYR18SEERMINISPLITMONTREAL_0be1f286-7349-4221-bceb-6d24b2de7aec.png?v=1697733986"},{"product_id":"thermopompe-murale-zephyr-18-de-18-000-btu-montreal","title":"Wall Mounted Heat Pump Zephyr 18 of 18 000 BTU Montreal","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInstallation and distribution of the Zephyr 18 wall-mounted heat pump 18,000 BTU, throughout Greater Montreal.\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eOur Zephyr heat pump is an inverter heat pump designed according to our specifications and fully compliant with Quebec standards.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eA high energy-efficiency inverter wall-mounted heat pump, with a \u003cstrong data-mce-fragment=\"1\"\u003eTOSHIBA compressor\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe condenser of the Zephyr heat pump absorbs more heat during heating thanks to 2 rows of absorption surfaces compared to 1.5 in other brands.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith ultra-wide frequency control technology, the heat pump intelligently regulates the operating frequency based on temperature variations. The control is more precise and prevents fluctuations in ambient temperature, allowing you to stay comfortable.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe heating mode of the Zephyr heat pump produces heat at very low winter temperatures. Heat generation at a temperature of -20°C is achieved thanks to preheating technology and electric chassis heating.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eNote that the Zephyr 17 was upgraded in 2021 to become the Zephyr 18.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":44553279013156,"sku":"ZE-18CA17","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/products\/THERMOPOMPEMURALEZEPHYR18SEERMINISPLITMONTREAL_27316eea-feb0-4921-9069-3fb4d9d43ee6.png?v=1697733990"},{"product_id":"thermopompe-murale-zephyr-18-de-12-000-btu-montreal","title":"Wall Mounted Heat Pump Zephyr 18 of 12 000 BTU Montreal","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInstallation and distribution of the Zephyr 18 12,000 BTU wall-mounted heat pump, throughout Greater Montreal.\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eOur Zephyr heat pump is an inverter heat pump designed according to our specifications and fully compliant with Quebec standards.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eA high energy-efficiency inverter wall-mounted heat pump, with a \u003cstrong data-mce-fragment=\"1\"\u003eTOSHIBA compressor\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe condenser of the Zephyr heat pump absorbs more heat during heating thanks to 2 rows of absorption surfaces compared to 1.5 in other brands.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith ultra-wide frequency control technology, the heat pump intelligently regulates the operating frequency based on temperature variations. The control is more precise and prevents fluctuations in ambient temperature, allowing you to stay comfortable.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe heating mode of the Zephyr heat pump produces heat even at very low winter temperatures. Heat generation at -20°C is achieved thanks to preheating technology and electric chassis heating.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eNote that the Zephyr 17 was upgraded in 2021 to become the Zephyr 18.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":44553279144228,"sku":"ZE-12CA17","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/products\/THERMOPOMPEMURALEZEPHYR18SEERMINISPLITMONTREAL.png?v=1697733987"},{"product_id":"thermopompe-murale-zephyr-18-de-9-000-btu-montreal","title":"Wall Mounted Heat Pump Zephyr 18 of 9 000 BTU Montreal","description":"\u003ch2\u003eInstallation and distribution of the\u0026nbsp;\u003cmeta charset=\"utf-8\"\u003e9 000 BTU Zephyr 18 wall-mounted heat pump, throughout Greater Montreal.\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/h2\u003e\n\u003cp\u003eOur Zephyr heat pump is an inverter\u0026nbsp;mini split created according to our requirements and fully respecting Quebec standards.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eA high energy efficiency inverter wall-mounted heat pump, with a TOSHIBA compressor.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe Zephyr heat pump condenser absorbs more heat in heating thanks to the 2 rows of absorption surfaces compared to 1.5 of other brands.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eWith ultra-wide frequency control technology, the heat pump intelligently regulates the operating frequency according to temperature variations. Control is more precise and prevents fluctuations in room temperature, keeping you comfortable.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe heating mode of the Zephyr heat pump produces heat at very low winter temperatures. The generation of heat at a temperature of -20°C is obtained thanks to the preheating technology and the electric heating of the chassis.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eNote that the Zephyr 17 was improved in 2021 to become the Zephyr 18.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":44553279439140,"sku":"ZE-09DA17","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/products\/THERMOPOMPEMURALEZEPHYR18SEERMINISPLITMONTREAL_e580a719-d7f9-4948-b106-eea3555d197d.png?v=1697733988"},{"product_id":"thermopompe-murale-zephyr-23-de-12-000-btu-montreal","title":"Wall Mounted Heat Pump Zephyr 23 of 12 000 BTU Montreal","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003eInstallation and distribution of the\u0026nbsp;\u003cmeta charset=\"utf-8\"\u003e12 000 BTU Zephyr 23 wall-mounted heat pump, throughout Greater Montreal.\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eOur Zephyr 23 heat pump is an Inverter-type wall-mounted mini split. This machine was created according to our requirements, in full compliance with Quebec standards.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eUp to 22 SEER \/ 11 HSPF\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCools down to -18°C\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eHeats up to -25°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eA high energy efficiency inverter wall-mounted heat pump, with a \u003cstrong data-mce-fragment=\"1\"\u003eTOSHIBA compressor\u003c\/strong\u003e.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe Zephyr heat pump condenser absorbs more heat in heating thanks to the 2 rows of absorption surfaces compared to the 1.5 of other brands.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eWith ultra-wide frequency control technology, the heat pump intelligently regulates the operating frequency according to temperature variations. Control is more precise and prevents fluctuations in room temperature, keeping you comfortable.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe heating mode of the Zephyr heat pump produces heat at very low winter temperatures, down to -25°C!\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eNote that in 2021, the Zephyr 22 was improved to become the Zephyr 23.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":44553607512356,"sku":"ZE-12CA22","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/products\/THERMOPOMPEMURALEZEPHYR23SEERMINISPLITMONTREAL.png?v=1697733990"},{"product_id":"thermopompe-murale-zephyr-23-de-18-000-btu-montreal","title":"Wall Mounted Heat Pump Zephyr 23 of 18 000 BTU Montreal","description":"\u003ch2\u003eInstallation and distribution of the\u0026nbsp;\u003cmeta charset=\"utf-8\"\u003e18 000 BTU Zephyr 23 wall-mounted heat pump, throughout Greater Montreal.\u003c\/h2\u003e\n\u003cp\u003e\u003cbr data-mce-fragment=\"1\"\u003eOur Zephyr 23 heat pump is an Inverter-type wall-mounted mini split. This machine was created according to our requirements, in full compliance with Quebec standards.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 22 SEER \/ 11 HSPF\u003c\/li\u003e\n\u003cli\u003eCools down to -18°C\u003c\/li\u003e\n\u003cli\u003eHeats up to -25°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA high energy efficiency inverter wall-mounted heat pump, with a \u003cstrong\u003eTOSHIBA compressor\u003c\/strong\u003e.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe Zephyr heat pump condenser absorbs more heat in heating thanks to the 2 rows of absorption surfaces compared to the 1.5 of other brands.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eWith ultra-wide frequency control technology, the heat pump intelligently regulates the operating frequency according to temperature variations. Control is more precise and prevents fluctuations in room temperature, keeping you comfortable.\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eThe heating mode of the Zephyr heat pump produces heat at very low winter temperatures, down to -25°C!\u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003eNote that in 2021, the Zephyr 22 was improved to become the Zephyr 23.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":44553607545124,"sku":"ZE-18CA22","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/products\/THERMOPOMPEMURALEZEPHYR23SEERMINISPLITMONTREAL_8cfddb7f-3895-4b28-803e-a4c13ff7b9be.png?v=1697733992"},{"product_id":"thermopompe-murale-zephyr-serie-23-9-000-btu-115v-r-32-montreal-laval-longueuil-rive-sud-rive-nord","title":"Zephyr Series 23 Wall Mounted Heat Pump | 9,000 BTU 115V R-32 | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":49795706880292,"sku":"ZE-09DB22O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEMURALEZEPHYRR329000BTUMONTREAL_LAVAL_LONGUEUIL_RIVESUD_RIVENORD_136f2dc6-9fb8-4b96-864f-38443a33296e.png?v=1762180241"},{"product_id":"thermopompe-murale-zephyr-serie-23-12-000-btu-115v-r-32-montreal-laval-longueuil-rive-sud-rive-nord","title":"Zephyr Series 23 Wall Mounted Heat Pump | 12,000 BTU 115V R-32 | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":49795706978596,"sku":"ZE-12DB22O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEMURALEZEPHYRR3212000BTUMONTREAL_LAVAL_LONGUEUIL_RIVESUD_RIVENORD_9af5f5c6-57da-467f-9e64-77706b784aec.png?v=1762180234"},{"product_id":"thermopompe-murale-zephyr-serie-23-9-000-btu-r-32-montreal-laval-longueuil-rive-sud-rive-nord","title":"Zephyr Series 23 Wall Mounted Heat Pump | 9,000 BTU R-32 | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":49795707076900,"sku":"ZE-09CB22O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEMURALEZEPHYRR329000BTUMONTREAL_LAVAL_LONGUEUIL_RIVESUD_RIVENORD.png?v=1762180228"},{"product_id":"thermopompe-murale-zephyr-serie-23-12-000-btu-r-32-montreal-laval-longueuil-rive-sud-rive-nord","title":"Zephyr Series 23 Wall Mounted Heat Pump | 12,000 BTU R-32 | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":49795707142436,"sku":"ZE-12CB22O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEMURALEZEPHYRR3212000BTUMONTREAL_LAVAL_LONGUEUIL_RIVESUD_RIVENORD.png?v=1762180222"},{"product_id":"thermopompe-murale-zephyr-serie-23-18-000-btu-r-32-montreal-laval-longueuil-rive-sud-rive-nord","title":"Zephyr Series 23 Wall Mounted Heat Pump | 18,000 BTU R-32 | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":49795707339044,"sku":"ZE-18CB22O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEMURALEZEPHYRR3218000BTUMONTREAL_LAVAL_LONGUEUIL_RIVESUD_RIVENORD.png?v=1762180215"},{"product_id":"thermopompe-murale-zephyr-serie-23-24-000-btu-r-32-montreal-laval-longueuil-rive-sud-rive-nord","title":"Zephyr Series 23 Wall Mounted Heat Pump | 24,000 BTU R-32 | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":49795707371812,"sku":"ZE-24CB22O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEMURALEZEPHYRR3224000BTUMONTREAL_LAVAL_LONGUEUIL_RIVESUD_RIVENORD.png?v=1762180208"},{"product_id":"thermopompe-murale-zephyr-serie-25-9-000-btu-115v-r-454b-montreal-laval-longueuil-rive-sud-rive-nord","title":"Zephyr 25 Series Wall Mounted Heat Pump | 9,000 BTU 115V R-454B | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":49795707437348,"sku":"ZE-09DB25O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEMURALEZEPHYRR454BMONTREAL_LAVAL_LONGUEUIL_RIVESUD_RIVENORD_ba06a8cc-0857-41dc-9005-815fe7f47c2e.png?v=1762180200"},{"product_id":"thermopompe-murale-zephyr-serie-25-12-000-btu-115v-r-454b-montreal-laval-longueuil-rive-sud-rive-nord","title":"Zephyr Series 25 Wall Mounted Heat Pump | 12,000 BTU 115V R-454B | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":49795707502884,"sku":"ZE-12DB25O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEMURALEZEPHYRR454BMONTREAL_LAVAL_LONGUEUIL_RIVESUD_RIVENORD.png?v=1762180193"},{"product_id":"thermopompe-murale-zephyr-serie-25-9-000-btu-r-454b-montreal-laval-longueuil-rive-sud-rive-nord","title":"Zephyr Series 25 Wall Mounted Heat Pump | 9,000 BTU R-454B | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA High-Performance Heating and Cooling Solution for Montreal, Laval, and Surrounding Areas\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWhen Quebec’s winter brings its biting cold or summer turns your home into an oven, having a \u003cstrong data-mce-fragment=\"1\"\u003ereliable heating and cooling solution\u003c\/strong\u003e is essential. The \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25 | 9,000 BTU R-454B wall-mounted heat pump\u003c\/strong\u003e is the ideal choice, designed to provide \u003cstrong data-mce-fragment=\"1\"\u003eoptimal energy efficiency\u003c\/strong\u003e, \u003cstrong data-mce-fragment=\"1\"\u003eexceptional performance even at -30°C\u003c\/strong\u003e, and unmatched comfort. Whether you’re in \u003cstrong data-mce-fragment=\"1\"\u003eMontreal, Laval, Longueuil, the South Shore, or the North Shore\u003c\/strong\u003e, this heat pump is the perfect answer to your \u003cstrong data-mce-fragment=\"1\"\u003eheating and cooling needs\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWhy Choose the Zephyr Series 25 Wall-Mounted Heat Pump?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25\u003c\/strong\u003e is not just another wall-mounted heat pump. It represents a \u003cstrong data-mce-fragment=\"1\"\u003etechnological evolution\u003c\/strong\u003e that offers superior performance, reduced energy consumption, and enhanced durability. Here are the \u003cstrong data-mce-fragment=\"1\"\u003ekey advantages\u003c\/strong\u003e that make this unit an undeniable choice:\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e1. Outstanding Performance Down to -30°C in Heating Mode\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eOne of the biggest strengths of this heat pump is its \u003cstrong data-mce-fragment=\"1\"\u003eability to function efficiently in heating mode even in extreme temperatures\u003c\/strong\u003e. Thanks to its \u003cstrong data-mce-fragment=\"1\"\u003eintelligent compressor and preheating system\u003c\/strong\u003e, it guarantees a \u003cstrong data-mce-fragment=\"1\"\u003econstant heat supply\u003c\/strong\u003e, even when the thermometer plunges to \u003cstrong data-mce-fragment=\"1\"\u003e-30°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e2. Remarkable Energy Efficiency\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith a \u003cstrong data-mce-fragment=\"1\"\u003eSEER2 of 25.0\u003c\/strong\u003e, an \u003cstrong data-mce-fragment=\"1\"\u003eHSPF2 of 11.0\u003c\/strong\u003e, and an \u003cstrong data-mce-fragment=\"1\"\u003eEER2 of 13.65\u003c\/strong\u003e, this heat pump ranks among the most efficient models on the market. This means \u003cstrong data-mce-fragment=\"1\"\u003elower energy consumption\u003c\/strong\u003e while maintaining \u003cstrong data-mce-fragment=\"1\"\u003eoptimal heating and cooling power\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e3. An Eco-Friendly Refrigerant: R-454B\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eUnlike older heat pump models that use R-410A, the \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25 operates with R-454B\u003c\/strong\u003e, a refrigerant that is much more environmentally friendly and has a \u003cstrong data-mce-fragment=\"1\"\u003elower impact on global warming\u003c\/strong\u003e. This choice helps \u003cstrong data-mce-fragment=\"1\"\u003ereduce your carbon footprint\u003c\/strong\u003e while ensuring maximum performance.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e4. Enhanced Comfort with Even Air Distribution\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe integrated \u003cstrong data-mce-fragment=\"1\"\u003e4D automatic oscillation technology\u003c\/strong\u003e allows for \u003cstrong data-mce-fragment=\"1\"\u003eoptimal air distribution throughout the room\u003c\/strong\u003e, eliminating cold spots and ensuring a \u003cstrong data-mce-fragment=\"1\"\u003econsistent temperature\u003c\/strong\u003e all year long.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e5. Easy Installation and Maintenance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDesigned for \u003cstrong data-mce-fragment=\"1\"\u003equick access to internal components\u003c\/strong\u003e, maintaining the \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25\u003c\/strong\u003e is simple and hassle-free. Its \u003cstrong data-mce-fragment=\"1\"\u003etwo-way drainage system\u003c\/strong\u003e also makes installation more flexible for various residential setups.\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDetailed Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eHere are the \u003cstrong data-mce-fragment=\"1\"\u003etechnical specifications\u003c\/strong\u003e that make the \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25 | 9,000 BTU R-454B heat pump\u003c\/strong\u003e an essential choice:\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMain Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCooling Capacity:\u003c\/strong\u003e 9,000 BTU\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eHeating Capacity:\u003c\/strong\u003e Up to \u003cstrong data-mce-fragment=\"1\"\u003e-30°C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eRefrigerant Gas:\u003c\/strong\u003e R-454B\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSEER2:\u003c\/strong\u003e 25.0\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eHSPF2:\u003c\/strong\u003e 11.0\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eEER2:\u003c\/strong\u003e 13.65\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eVoltage:\u003c\/strong\u003e 220V\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIndoor Sound Level:\u003c\/strong\u003e 32 \/ 42 dB(A)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eOutdoor Sound Level:\u003c\/strong\u003e 53 dB(A)\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCertifications:\u003c\/strong\u003e \u003cstrong data-mce-fragment=\"1\"\u003eENERGY STAR®\u003c\/strong\u003e, \u003cstrong data-mce-fragment=\"1\"\u003eAHRI\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAdvanced Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e✅ \u003cstrong data-mce-fragment=\"1\"\u003eSleep Mode\u003c\/strong\u003e for noise reduction and temperature regulation for better sleep\u003cbr data-mce-fragment=\"1\"\u003e✅ \u003cstrong data-mce-fragment=\"1\"\u003eSilent Mode\u003c\/strong\u003e for ultra-quiet operation\u003cbr data-mce-fragment=\"1\"\u003e✅ \u003cstrong data-mce-fragment=\"1\"\u003eFast Cool\/Heat\u003c\/strong\u003e for instant temperature adjustments\u003cbr data-mce-fragment=\"1\"\u003e✅ \u003cstrong data-mce-fragment=\"1\"\u003eFire-Proof Electrical Box\u003c\/strong\u003e for enhanced safety\u003cbr data-mce-fragment=\"1\"\u003e✅ \u003cstrong data-mce-fragment=\"1\"\u003eChassis and Compressor Heating\u003c\/strong\u003e to prevent freezing in winter\u003cbr data-mce-fragment=\"1\"\u003e✅ \u003cstrong data-mce-fragment=\"1\"\u003eAuto-Cleaning System\u003c\/strong\u003e for easier maintenance and extended lifespan\u003cbr data-mce-fragment=\"1\"\u003e✅ \u003cstrong data-mce-fragment=\"1\"\u003eI-Feel Mode\u003c\/strong\u003e: Adjusts temperature based on remote control location\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWhy Is This Heat Pump Perfect for Your Home?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25 | 9,000 BTU R-454B\u003c\/strong\u003e is specially designed to meet the \u003cstrong data-mce-fragment=\"1\"\u003eneeds of homeowners in Montreal, Laval, Longueuil, the South Shore, and the North Shore\u003c\/strong\u003e. It is a \u003cstrong data-mce-fragment=\"1\"\u003eperfect solution for condos, apartments, and single-family homes\u003c\/strong\u003e looking for \u003cstrong data-mce-fragment=\"1\"\u003eultra-efficient heating and cooling\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e🌡️ Reliable Performance Year-Round\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWhether you need \u003cstrong data-mce-fragment=\"1\"\u003ecooling in the summer\u003c\/strong\u003e or \u003cstrong data-mce-fragment=\"1\"\u003eheating in the depths of winter\u003c\/strong\u003e, this heat pump delivers with \u003cstrong data-mce-fragment=\"1\"\u003econsistent temperature control\u003c\/strong\u003e and low energy consumption.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e💰 Significant Energy Savings\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThanks to its \u003cstrong data-mce-fragment=\"1\"\u003eexceptional energy efficiency\u003c\/strong\u003e, this heat pump helps \u003cstrong data-mce-fragment=\"1\"\u003ereduce your electricity bill\u003c\/strong\u003e, especially when replacing traditional electric heating systems.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e🔧 A Long-Term Investment\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith a \u003cstrong data-mce-fragment=\"1\"\u003e10-year warranty on the compressor and parts\u003c\/strong\u003e, this heat pump is a \u003cstrong data-mce-fragment=\"1\"\u003esafe and durable investment\u003c\/strong\u003e for your home.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e📡 Available Subsidies\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eGreat news! The \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25\u003c\/strong\u003e is eligible for the \u003cstrong data-mce-fragment=\"1\"\u003eHydro-Québec LogisVert subsidy\u003c\/strong\u003e, allowing you to save \u003cstrong data-mce-fragment=\"1\"\u003e$450\u003c\/strong\u003e on your purchase.\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInstallation and Maintenance: AirGreen, Your Wall-Mounted Heat Pump Experts\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAt \u003cstrong data-mce-fragment=\"1\"\u003eAirGreen\u003c\/strong\u003e, we specialize in \u003cstrong data-mce-fragment=\"1\"\u003einstalling wall-mounted heat pumps\u003c\/strong\u003e in \u003cstrong data-mce-fragment=\"1\"\u003eMontreal, Laval, Longueuil, the South Shore, and the North Shore\u003c\/strong\u003e. Our team of certified technicians guarantees a \u003cstrong data-mce-fragment=\"1\"\u003efast, efficient, and code-compliant installation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eHow Does the Installation Process Work?\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003e1️⃣ \u003cstrong data-mce-fragment=\"1\"\u003eAssessment of your needs and selection of the optimal installation location\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e2️⃣ \u003cstrong data-mce-fragment=\"1\"\u003eInstallation of the indoor and outdoor units\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e3️⃣ \u003cstrong data-mce-fragment=\"1\"\u003eConnection and activation\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e4️⃣ \u003cstrong data-mce-fragment=\"1\"\u003eExplanation of features and usage tips\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch4 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eRegular Maintenance for Optimal Performance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-mce-fragment=\"1\"\u003eTo ensure \u003cstrong data-mce-fragment=\"1\"\u003eefficient and long-lasting operation\u003c\/strong\u003e, we recommend \u003cstrong data-mce-fragment=\"1\"\u003eregular maintenance\u003c\/strong\u003e of your heat pump:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eClean the \u003cstrong data-mce-fragment=\"1\"\u003eair filters\u003c\/strong\u003e every month\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCheck the \u003cstrong data-mce-fragment=\"1\"\u003edrainage system\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInspect \u003cstrong data-mce-fragment=\"1\"\u003erefrigerant levels\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eClean the \u003cstrong data-mce-fragment=\"1\"\u003eheat exchangers\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eOur technicians are available for an \u003cstrong data-mce-fragment=\"1\"\u003eannual maintenance service\u003c\/strong\u003e to keep your heat pump running at peak performance.\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConclusion: A Smart Choice for Year-Round Comfort\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25 | 9,000 BTU R-454B wall-mounted heat pump\u003c\/strong\u003e stands out as \u003cstrong data-mce-fragment=\"1\"\u003ea high-end solution\u003c\/strong\u003e for home heating and cooling. Its \u003cstrong data-mce-fragment=\"1\"\u003eenergy efficiency\u003c\/strong\u003e, \u003cstrong data-mce-fragment=\"1\"\u003eability to function even at -30°C\u003c\/strong\u003e, \u003cstrong data-mce-fragment=\"1\"\u003ecompact design\u003c\/strong\u003e, and \u003cstrong data-mce-fragment=\"1\"\u003eadvanced technology\u003c\/strong\u003e make it an ideal choice for homeowners looking for \u003cstrong data-mce-fragment=\"1\"\u003ecomfort and energy savings\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAt \u003cstrong data-mce-fragment=\"1\"\u003eAirGreen\u003c\/strong\u003e, we are here to \u003cstrong data-mce-fragment=\"1\"\u003eguide and assist\u003c\/strong\u003e you in purchasing, installing, and maintaining your heat pump. \u003cstrong data-mce-fragment=\"1\"\u003eContact us today\u003c\/strong\u003e for a free quote and find out how you can upgrade your home comfort right away!\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":49795707568420,"sku":"ZE-09CB25O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEMURALEZEPHYRR454B9000BTUMONTREAL_LAVAL_LONGUEUIL_RIVESUD_RIVENORD.png?v=1762180179"},{"product_id":"thermopompe-murale-zephyr-serie-25-12-000-btu-r-454b-montreal-laval-longueuil-rive-sud-rive-nord","title":"Zephyr Series 25 Wall Mounted Heat Pump | 12,000 BTU R-454B | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA high-performance wall-mounted heat pump designed for Quebec's climate\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWhen it comes to \u003cstrong data-mce-fragment=\"1\"\u003eheating and cooling\u003c\/strong\u003e in \u003cstrong data-mce-fragment=\"1\"\u003eMontreal, Laval, Longueuil, the South Shore, and the North Shore\u003c\/strong\u003e, choosing a \u003cstrong data-mce-fragment=\"1\"\u003ereliable, efficient\u003c\/strong\u003e system built to withstand harsh winters and hot summers is crucial. The \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25 Wall-Mounted Heat Pump\u003c\/strong\u003e with \u003cstrong data-mce-fragment=\"1\"\u003e12,000 BTU\u003c\/strong\u003e and \u003cstrong data-mce-fragment=\"1\"\u003eR-454B refrigerant\u003c\/strong\u003e stands out with its \u003cstrong data-mce-fragment=\"1\"\u003eenergy efficiency, advanced technology, and exceptional comfort\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eTop-tier energy efficiency for lower electricity consumption\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eImpressive performance certified by ENERGY STAR®\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25\u003c\/strong\u003e boasts \u003cstrong data-mce-fragment=\"1\"\u003esuperior energy efficiency\u003c\/strong\u003e, with a \u003cstrong data-mce-fragment=\"1\"\u003eSEER2 rating of 23.0\u003c\/strong\u003e, an \u003cstrong data-mce-fragment=\"1\"\u003eHSPF2 of 10.0\u003c\/strong\u003e, and an \u003cstrong data-mce-fragment=\"1\"\u003eEER2 of 12.25\u003c\/strong\u003e. These ratings translate into \u003cstrong data-mce-fragment=\"1\"\u003ereduced energy consumption\u003c\/strong\u003e for both heating and cooling, leading to \u003cstrong data-mce-fragment=\"1\"\u003esignificant savings on your electricity bills\u003c\/strong\u003e. Certified \u003cstrong data-mce-fragment=\"1\"\u003eENERGY STAR®\u003c\/strong\u003e, this heat pump qualifies for the \u003cstrong data-mce-fragment=\"1\"\u003eHydro-Québec LogisVert rebate\u003c\/strong\u003e of \u003cstrong data-mce-fragment=\"1\"\u003e$1,296\u003c\/strong\u003e, significantly lowering the cost of acquisition.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA more eco-friendly refrigerant: R-454B\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe \u003cstrong data-mce-fragment=\"1\"\u003eR-454B refrigerant\u003c\/strong\u003e used in the \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25\u003c\/strong\u003e is a \u003cstrong data-mce-fragment=\"1\"\u003emore environmentally friendly alternative\u003c\/strong\u003e to older refrigerants like \u003cstrong data-mce-fragment=\"1\"\u003eR-410A\u003c\/strong\u003e. With a \u003cstrong data-mce-fragment=\"1\"\u003elower global warming potential (GWP)\u003c\/strong\u003e, it \u003cstrong data-mce-fragment=\"1\"\u003ereduces environmental impact\u003c\/strong\u003e without compromising thermal performance.\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eReliable heating down to -30°C: your best ally for Quebec winters\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAdvanced technology for maximum performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eUnlike many heat pumps that struggle in extreme cold, the \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25\u003c\/strong\u003e is engineered to \u003cstrong data-mce-fragment=\"1\"\u003eheat efficiently even at -30°C\u003c\/strong\u003e. Its \u003cstrong data-mce-fragment=\"1\"\u003epreheating compressor technology\u003c\/strong\u003e and \u003cstrong data-mce-fragment=\"1\"\u003eintegrated chassis heating belt\u003c\/strong\u003e optimize performance and \u003cstrong data-mce-fragment=\"1\"\u003eprevent breakdowns in freezing temperatures\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAn optimized condenser for better heat absorption\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eOne of the key advantages of the Zephyr’s \u003cstrong data-mce-fragment=\"1\"\u003eheating performance\u003c\/strong\u003e is its \u003cstrong data-mce-fragment=\"1\"\u003ehigh-performance condenser\u003c\/strong\u003e, which \u003cstrong data-mce-fragment=\"1\"\u003eabsorbs more heat than most competing models\u003c\/strong\u003e. While standard heat pumps have \u003cstrong data-mce-fragment=\"1\"\u003e1.5 rows of heat absorption surfaces\u003c\/strong\u003e, the \u003cstrong data-mce-fragment=\"1\"\u003eZephyr features 2 rows\u003c\/strong\u003e, providing \u003cstrong data-mce-fragment=\"1\"\u003ebetter heating capacity, even in extreme cold\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePowerful cooling down to -15°C: perfect for all seasons\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25\u003c\/strong\u003e isn’t just impressive in heating mode; it also \u003cstrong data-mce-fragment=\"1\"\u003eexcels in cooling\u003c\/strong\u003e. With a \u003cstrong data-mce-fragment=\"1\"\u003ecooling capacity down to -15°C\u003c\/strong\u003e, it is ideal for \u003cstrong data-mce-fragment=\"1\"\u003especial installations\u003c\/strong\u003e, such as \u003cstrong data-mce-fragment=\"1\"\u003ecooling data center equipment\u003c\/strong\u003e or maintaining \u003cstrong data-mce-fragment=\"1\"\u003estable indoor temperatures in commercial or residential settings\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAbsolute comfort with intelligent features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e4D oscillation: better air distribution in the room\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eUnlike basic models that \u003cstrong data-mce-fragment=\"1\"\u003edirect airflow in just one direction\u003c\/strong\u003e, the \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25\u003c\/strong\u003e features a \u003cstrong data-mce-fragment=\"1\"\u003e4D auto-swing mode\u003c\/strong\u003e, distributing air in \u003cstrong data-mce-fragment=\"1\"\u003efour directions\u003c\/strong\u003e. This helps \u003cstrong data-mce-fragment=\"1\"\u003eeliminate cold or hot spots\u003c\/strong\u003e and ensures \u003cstrong data-mce-fragment=\"1\"\u003econsistent, even temperatures throughout the space\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSleep mode and quiet mode for optimal comfort\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith a \u003cstrong data-mce-fragment=\"1\"\u003enoise level of just 32 dB(A) in silent mode\u003c\/strong\u003e, this heat pump is \u003cstrong data-mce-fragment=\"1\"\u003eperfect for bedrooms or offices\u003c\/strong\u003e. Its \u003cstrong data-mce-fragment=\"1\"\u003esleep mode\u003c\/strong\u003e automatically adjusts \u003cstrong data-mce-fragment=\"1\"\u003etemperature and fan speed\u003c\/strong\u003e to provide \u003cstrong data-mce-fragment=\"1\"\u003ea comfortable atmosphere without abrupt changes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIFEEL technology for precise temperature adjustments\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThanks to its \u003cstrong data-mce-fragment=\"1\"\u003esmart remote control with IFEEL mode\u003c\/strong\u003e, the Zephyr adjusts the temperature \u003cstrong data-mce-fragment=\"1\"\u003ebased on the actual position of the user\u003c\/strong\u003e. Simply place the remote near you, and the heat pump \u003cstrong data-mce-fragment=\"1\"\u003eautomatically adapts its performance for maximum comfort\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eReliability and durability: a robust and secure design\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFire-proof electric box for enhanced safety\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eOne of the standout features of the \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25\u003c\/strong\u003e is its \u003cstrong data-mce-fragment=\"1\"\u003efire-proof electric box\u003c\/strong\u003e, which provides \u003cstrong data-mce-fragment=\"1\"\u003eextra protection against overheating risks\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eImproved drainage system\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith its \u003cstrong data-mce-fragment=\"1\"\u003etwo-way drainage system\u003c\/strong\u003e, this heat pump \u003cstrong data-mce-fragment=\"1\"\u003eallows for more flexible installation options\u003c\/strong\u003e and prevents \u003cstrong data-mce-fragment=\"1\"\u003ewater accumulation issues\u003c\/strong\u003e that are common with other models.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAuto-restart and intelligent defrosting system\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIn the event of a \u003cstrong data-mce-fragment=\"1\"\u003epower outage\u003c\/strong\u003e, the Zephyr \u003cstrong data-mce-fragment=\"1\"\u003eautomatically restarts with the same settings\u003c\/strong\u003e as before. Additionally, its \u003cstrong data-mce-fragment=\"1\"\u003eintelligent defrosting system\u003c\/strong\u003e prevents ice buildup on the \u003cstrong data-mce-fragment=\"1\"\u003eoutdoor unit\u003c\/strong\u003e, ensuring \u003cstrong data-mce-fragment=\"1\"\u003econsistent performance even in winter\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInstallation and maintenance: simple and hassle-free\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eQuick and efficient installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith its \u003cstrong data-mce-fragment=\"1\"\u003ecompact dimensions\u003c\/strong\u003e (32.88 x 11 x 8.69 in for the indoor unit and 31.88 x 11 x 23 in for the outdoor unit), the Zephyr can be easily installed in \u003cstrong data-mce-fragment=\"1\"\u003evarious types of homes\u003c\/strong\u003e, including houses, condos, and apartments. Running on \u003cstrong data-mce-fragment=\"1\"\u003e220V\u003c\/strong\u003e, it is \u003cstrong data-mce-fragment=\"1\"\u003efully compatible with residential electrical systems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eMinimal maintenance for a longer lifespan\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe Zephyr is equipped with an \u003cstrong data-mce-fragment=\"1\"\u003eauto-cleaning system\u003c\/strong\u003e, which reduces \u003cstrong data-mce-fragment=\"1\"\u003edust and bacteria buildup\u003c\/strong\u003e on the \u003cstrong data-mce-fragment=\"1\"\u003eevaporator coil\u003c\/strong\u003e. Its \u003cstrong data-mce-fragment=\"1\"\u003eintelligent preheated compressor\u003c\/strong\u003e and \u003cstrong data-mce-fragment=\"1\"\u003ehigh-quality components\u003c\/strong\u003e ensure \u003cstrong data-mce-fragment=\"1\"\u003ea longer lifespan and minimal maintenance requirements\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWhy choose the Zephyr Series 25 Wall-Mounted Heat Pump?\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003e✔ \u003cstrong data-mce-fragment=\"1\"\u003eReliable heating down to -30°C\u003c\/strong\u003e, perfect for Quebec’s climate\u003cbr data-mce-fragment=\"1\"\u003e✔ \u003cstrong data-mce-fragment=\"1\"\u003eExceptional energy efficiency (SEER2 of 23.0, HSPF2 of 10.0, EER2 of 12.25)\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e✔ \u003cstrong data-mce-fragment=\"1\"\u003eEffective cooling even at -15°C\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e✔ \u003cstrong data-mce-fragment=\"1\"\u003e4D oscillation mode for better airflow distribution\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e✔ \u003cstrong data-mce-fragment=\"1\"\u003eUltra-quiet operation with sleep mode for maximum comfort\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e✔ \u003cstrong data-mce-fragment=\"1\"\u003eIFEEL technology for precise temperature adjustments\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e✔ \u003cstrong data-mce-fragment=\"1\"\u003eEnhanced safety features, including a fire-proof electric box\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e✔ \u003cstrong data-mce-fragment=\"1\"\u003eEasy installation and low maintenance\u003c\/strong\u003e\u003cbr data-mce-fragment=\"1\"\u003e✔ \u003cstrong data-mce-fragment=\"1\"\u003eEligible for the Hydro-Québec LogisVert rebate of $1,296\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eBy choosing the \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25\u003c\/strong\u003e, you are investing in a \u003cstrong data-mce-fragment=\"1\"\u003ehigh-performance, reliable, and Quebec-ready wall-mounted heat pump\u003c\/strong\u003e. Whether you live in \u003cstrong data-mce-fragment=\"1\"\u003eMontreal, Laval, Longueuil, the South Shore, or the North Shore\u003c\/strong\u003e, this heat pump is a \u003cstrong data-mce-fragment=\"1\"\u003esmart choice for both comfort and savings\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":49795707633956,"sku":"ZE-12CB25O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEMURALEZEPHYRR454B12000BTUMONTREAL_LAVAL_LONGUEUIL_RIVESUD_RIVENORD.png?v=1762180167"},{"product_id":"thermopompe-murale-zephyr-serie-25-18-000-btu-r-454b-montreal-laval-longueuil-rive-sud-rive-nord","title":"Zephyr 25 Series Wall Mounted Heat Pump | 18,000 BTU R-454B | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch1 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25 Wall-Mounted Heat Pump | 18,000 BTU R-454B\u003c\/strong\u003e\u003c\/h1\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eUnmatched Performance and Energy Efficiency for Your Comfort in Montreal, Laval, Longueuil, South Shore, and North Shore\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWhen choosing a \u003cstrong data-mce-fragment=\"1\"\u003ewall-mounted heat pump\u003c\/strong\u003e that can withstand the harshness of our Quebec winters while delivering \u003cstrong data-mce-fragment=\"1\"\u003eexceptional cooling performance in the summer\u003c\/strong\u003e, the \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25 18,000 BTU R-454B\u003c\/strong\u003e stands out with its advanced features and outstanding energy efficiency.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWhy Choose the Zephyr Series 25 Wall-Mounted Heat Pump?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith its \u003cstrong data-mce-fragment=\"1\"\u003eimpressive performance\u003c\/strong\u003e and numerous features, this heat pump is designed to provide \u003cstrong data-mce-fragment=\"1\"\u003eabsolute comfort year-round\u003c\/strong\u003e. It is an ideal solution for homeowners in \u003cstrong data-mce-fragment=\"1\"\u003eMontreal, Laval, Longueuil, the South Shore, and the North Shore\u003c\/strong\u003e who are looking for reliable performance, simplified installation, and optimized energy consumption.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eDesigned for the Harshest Winters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eOne of the biggest challenges for heat pumps is their ability to \u003cstrong data-mce-fragment=\"1\"\u003eheat efficiently in extremely cold temperatures\u003c\/strong\u003e. The Zephyr Series 25 excels in this area with its ability to operate down to \u003cstrong data-mce-fragment=\"1\"\u003e-30°C (-22°F) in heating mode\u003c\/strong\u003e. This means that even in the depths of Quebec winter, you will enjoy a \u003cstrong data-mce-fragment=\"1\"\u003estable and comfortable indoor temperature\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCompressor Preheating Technology\u003c\/strong\u003e: Ensures optimal startup even in freezing weather.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eChassis Heating\u003c\/strong\u003e: Protects components from frost and extends the unit’s lifespan.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSmart Frequency Regulation\u003c\/strong\u003e: Adjusts power output based on outdoor temperatures for \u003cstrong data-mce-fragment=\"1\"\u003eoptimal efficiency and reduced energy consumption\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eHigh-Performance Cooling Even in Extreme Heat\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eSummers in Montreal and surrounding areas can bring intense heat waves. Fortunately, the \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25 provides powerful cooling\u003c\/strong\u003e even in temperatures as low as \u003cstrong data-mce-fragment=\"1\"\u003e-15°C (5°F) in cooling mode\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFast Cooling Mode\u003c\/strong\u003e: Quickly lowers indoor temperatures for immediate relief.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e4D Auto-Swing Mode\u003c\/strong\u003e: Evenly distributes cool air throughout the room, eliminating hot spots.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eUltra-Wide Frequency Control Technology\u003c\/strong\u003e: Stabilizes temperature and prevents uncomfortable fluctuations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA Next-Generation Refrigerant: R-454B\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eOne of the innovative aspects of this heat pump is its use of \u003cstrong data-mce-fragment=\"1\"\u003eR-454B refrigerant\u003c\/strong\u003e, an eco-friendly alternative to older refrigerants like R-410A.\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eReduced Environmental Impact\u003c\/strong\u003e: Lower global warming potential compared to R-410A.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eIncreased Energy Efficiency\u003c\/strong\u003e: Reduces electricity consumption while maintaining high performance.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCompliance with New Regulations\u003c\/strong\u003e: Anticipates future refrigerant regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eOptimized Installation Tailored to Quebec Homeowners\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThanks to its \u003cstrong data-mce-fragment=\"1\"\u003ecompact dimensions and intelligent design\u003c\/strong\u003e, the Zephyr Series 25 integrates seamlessly into any home.\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eStandardized Piping (1\/4 - 1\/2)\u003c\/strong\u003e: Compatible with most existing installations.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e220V Power Supply\u003c\/strong\u003e: Ensures stable and efficient operation.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eVersatile Mounting Options\u003c\/strong\u003e: Perfect for houses, condos, and multi-family dwellings.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSilent and Comfortable: A Discreet Operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eNo one wants a noisy heat pump disrupting their sleep or daily life. With an indoor noise level of \u003cstrong data-mce-fragment=\"1\"\u003e36 to 48 dB(A)\u003c\/strong\u003e, the \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25 is incredibly quiet\u003c\/strong\u003e, comparable to the rustling of leaves.\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eQuiet Mode\u003c\/strong\u003e: Further reduces operational noise.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eSleep Mode\u003c\/strong\u003e: Automatically adjusts temperature for a restful sleep.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e7-Speed Fan\u003c\/strong\u003e: Adjusts airflow to match your preferences.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA Strong Warranty for Total Peace of Mind\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWe understand that purchasing a heat pump is a \u003cstrong data-mce-fragment=\"1\"\u003esignificant investment\u003c\/strong\u003e. That’s why the Zephyr Series 25 comes with a \u003cstrong data-mce-fragment=\"1\"\u003e10-year warranty on both the compressor and parts\u003c\/strong\u003e. You also have the option to add an extended labor warranty, ensuring full coverage in case of any issues.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eHydro-Québec LogisVert Grant: A Financial Incentive You Shouldn’t Miss\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eBy choosing the Zephyr Series 25, you may be \u003cstrong data-mce-fragment=\"1\"\u003eeligible for a $2,160 grant through Hydro-Québec’s LogisVert program\u003c\/strong\u003e. This financial assistance is designed to encourage the installation of energy-efficient equipment to \u003cstrong data-mce-fragment=\"1\"\u003ereduce electricity consumption and the carbon footprint\u003c\/strong\u003e of Quebec households.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eComparison with Other Brands: Why Zephyr Stands Out\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25 wall-mounted heat pump offers superior heat absorption\u003c\/strong\u003e thanks to its \u003cstrong data-mce-fragment=\"1\"\u003etwo rows of heat absorption surfaces\u003c\/strong\u003e, whereas most other brands only have \u003cstrong data-mce-fragment=\"1\"\u003e1.5 rows\u003c\/strong\u003e. This results in \u003cstrong data-mce-fragment=\"1\"\u003ebetter heating efficiency\u003c\/strong\u003e, even when temperatures drop dramatically.\u003c\/p\u003e\n\u003ctable data-mce-fragment=\"1\"\u003e\n\u003cthead data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003cth data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eCriteria\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eOther Brands\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-mce-fragment=\"1\"\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eMax Heating Temp.\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e-30°C (-22°F)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e-25°C to -20°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eSEER2\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e21.0\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e18.0 to 20.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eIndoor Noise Level\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e36-48 dB(A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e42-55 dB(A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eRefrigerant Type\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eR-454B\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eR-410A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-mce-fragment=\"1\"\u003e\n\u003ctd data-mce-fragment=\"1\"\u003eCompressor Warranty\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e10 years\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-mce-fragment=\"1\"\u003e5 to 7 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWhy Choose AirGreen for Your Zephyr Heat Pump Installation?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAt \u003cstrong data-mce-fragment=\"1\"\u003eAirGreen\u003c\/strong\u003e, we have \u003cstrong data-mce-fragment=\"1\"\u003eproven expertise\u003c\/strong\u003e in installing \u003cstrong data-mce-fragment=\"1\"\u003ewall-mounted heat pumps in Montreal, Laval, Longueuil, the South Shore, and the North Shore\u003c\/strong\u003e. By choosing our team, you benefit from:\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e✅ \u003cstrong data-mce-fragment=\"1\"\u003eA turnkey service\u003c\/strong\u003e: From needs assessment to final installation.\u003cbr data-mce-fragment=\"1\"\u003e✅ \u003cstrong data-mce-fragment=\"1\"\u003eHighly trained technicians\u003c\/strong\u003e: Skilled in the latest HVAC technologies.\u003cbr data-mce-fragment=\"1\"\u003e✅ \u003cstrong data-mce-fragment=\"1\"\u003eResponsive after-sales service\u003c\/strong\u003e: Ongoing support and maintenance.\u003cbr data-mce-fragment=\"1\"\u003e✅ \u003cstrong data-mce-fragment=\"1\"\u003eOptimized installation\u003c\/strong\u003e: Guaranteed maximum performance and extended durability.\u003c\/p\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConclusion: The Ideal Heat Pump for Year-Round Comfort\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25 18,000 BTU R-454B\u003c\/strong\u003e is an \u003cstrong data-mce-fragment=\"1\"\u003eexcellent choice\u003c\/strong\u003e for those seeking a \u003cstrong data-mce-fragment=\"1\"\u003ehigh-performance, energy-efficient, and reliable wall-mounted heat pump\u003c\/strong\u003e. With its \u003cstrong data-mce-fragment=\"1\"\u003eexceptional heating capacity down to -30°C (-22°F), ultra-quiet operation, and eligibility for the LogisVert grant\u003c\/strong\u003e, it is the perfect solution for Quebec homes.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eTrust \u003cstrong data-mce-fragment=\"1\"\u003eAirGreen\u003c\/strong\u003e for a professional and optimized installation! Contact us today for a personalized quote.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":49795707765028,"sku":"ZE-18CB25O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEMURALEZEPHYRR454B18000BTUMONTREAL_LAVAL_LONGUEUIL_RIVESUD_RIVENORD.png?v=1762180155"},{"product_id":"thermopompe-murale-zephyr-serie-25-24-000-btu-r-454b-montreal-laval-longueuil-rive-sud-rive-nord","title":"Zephyr 25 Series Wall Mounted Heat Pump | 24,000 BTU R-454B | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003ch2 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA high-performance heating and cooling solution for Quebec’s climate\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWhen winter hits hard and summer brings crushing heat waves, having a \u003cstrong data-mce-fragment=\"1\"\u003ereliable and efficient heating and cooling system\u003c\/strong\u003e is essential. The \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25 Wall-Mounted Heat Pump | 24,000 BTU R-454B\u003c\/strong\u003e is the perfect solution for \u003cstrong data-mce-fragment=\"1\"\u003eoptimal year-round comfort\u003c\/strong\u003e, whether you live in \u003cstrong data-mce-fragment=\"1\"\u003eMontreal, Laval, Longueuil, the South Shore, or the North Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWhy choose the Zephyr Series 25 Heat Pump?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eBuying a heat pump is a \u003cstrong data-mce-fragment=\"1\"\u003estrategic investment\u003c\/strong\u003e that requires careful consideration. With the \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25\u003c\/strong\u003e, you get:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eExceptional energy efficiency\u003c\/strong\u003e: With a \u003cstrong data-mce-fragment=\"1\"\u003eSEER2 of 22.5\u003c\/strong\u003e, an \u003cstrong data-mce-fragment=\"1\"\u003eHSPF2 of 9.5\u003c\/strong\u003e, and an \u003cstrong data-mce-fragment=\"1\"\u003eEER2 of 12.25\u003c\/strong\u003e, this heat pump is designed to \u003cstrong data-mce-fragment=\"1\"\u003eminimize energy consumption\u003c\/strong\u003e while maximizing comfort.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePerformance adapted to Quebec’s climate\u003c\/strong\u003e: It maintains a \u003cstrong data-mce-fragment=\"1\"\u003eheating capacity down to -30°C\u003c\/strong\u003e, making it a perfect solution for the province’s harsh winters.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eNext-generation refrigerant: R-454B\u003c\/strong\u003e: More environmentally friendly than older refrigerants, reducing carbon footprint while ensuring optimal performance.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA simple and adaptable installation\u003c\/strong\u003e: Thanks to its \u003cstrong data-mce-fragment=\"1\"\u003ecompact design and dual-direction drainage system\u003c\/strong\u003e, this heat pump can be seamlessly integrated into different home layouts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eUnmatched heating performance, even at -30°C\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eQuebec’s harsh winters require a \u003cstrong data-mce-fragment=\"1\"\u003epowerful and stable heating system\u003c\/strong\u003e that remains effective even when temperatures drop well below zero. Unlike many heat pumps that struggle \u003cstrong data-mce-fragment=\"1\"\u003ebelow -20°C\u003c\/strong\u003e, the \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25\u003c\/strong\u003e is built to maintain \u003cstrong data-mce-fragment=\"1\"\u003econsistent heating capacity down to -30°C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eIts \u003cstrong data-mce-fragment=\"1\"\u003eintelligent preheating system\u003c\/strong\u003e and \u003cstrong data-mce-fragment=\"1\"\u003eheated chassis\u003c\/strong\u003e ensure \u003cstrong data-mce-fragment=\"1\"\u003equick startup and even heat distribution\u003c\/strong\u003e, without excessive energy consumption.\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003ePowerful cooling: say goodbye to sweltering summers!\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith a \u003cstrong data-mce-fragment=\"1\"\u003e24,000 BTU cooling capacity\u003c\/strong\u003e, this heat pump guarantees \u003cstrong data-mce-fragment=\"1\"\u003emaximum comfort in summer\u003c\/strong\u003e, even during extreme heat waves. Its \u003cstrong data-mce-fragment=\"1\"\u003e4D automatic oscillation system\u003c\/strong\u003e ensures \u003cstrong data-mce-fragment=\"1\"\u003euniform airflow distribution\u003c\/strong\u003e, eliminating unpleasant warm spots.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAdditionally, the \u003cstrong data-mce-fragment=\"1\"\u003e“Fast Cool” mode\u003c\/strong\u003e quickly reaches the desired temperature—ideal after a long day under the blazing sun.\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA device designed for comfort and peace of mind\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eTrue comfort also means having a \u003cstrong data-mce-fragment=\"1\"\u003equiet\u003c\/strong\u003e system. The \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25\u003c\/strong\u003e is engineered to minimize noise, featuring:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e39 dB(A) in silent mode\u003c\/strong\u003e: Nearly inaudible operation for an uninterrupted night’s sleep.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e50 dB(A) at full power\u003c\/strong\u003e: Minimal noise for optimal performance.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e61 dB(A) for the outdoor unit\u003c\/strong\u003e: Designed to blend seamlessly into its surroundings without disturbing neighbors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith its \u003cstrong data-mce-fragment=\"1\"\u003e“Silence” mode\u003c\/strong\u003e and \u003cstrong data-mce-fragment=\"1\"\u003e“Sleep” mode\u003c\/strong\u003e, the unit \u003cstrong data-mce-fragment=\"1\"\u003eautomatically adjusts its operation\u003c\/strong\u003e to maximize comfort—even at night.\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAdvanced technology for intelligent control\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25\u003c\/strong\u003e isn’t just powerful—it also comes equipped with smart features that make operation easy:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e“I Feel” mode\u003c\/strong\u003e: A sensor in the remote control automatically adjusts the temperature based on your location in the room.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003e24-hour timer\u003c\/strong\u003e: Program the heat pump to turn on or off according to your daily routine.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAuto Restart\u003c\/strong\u003e: In case of a power outage, the unit restarts automatically with the same settings.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAuto Cleaning\u003c\/strong\u003e: A self-cleaning system prevents dust and mold buildup, extending the lifespan of the unit.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eAutomatic defrosting\u003c\/strong\u003e: The heat pump detects and eliminates frost buildup to maintain optimal performance in winter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eA durable and secure system\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eBeyond performance and comfort, the \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25\u003c\/strong\u003e is designed for \u003cstrong data-mce-fragment=\"1\"\u003elongevity and maximum safety\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eFire-proof electrical box\u003c\/strong\u003e: Protects against overheating and fire risks.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eVoltage stabilization technology\u003c\/strong\u003e: Ensures stable operation even with voltage fluctuations between \u003cstrong data-mce-fragment=\"1\"\u003e150V and 264V\u003c\/strong\u003e, protecting internal components.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eReinforced chassis\u003c\/strong\u003e: Built to withstand Quebec’s extreme weather conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eInstallation and warranty: a worry-free choice\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAt \u003cstrong data-mce-fragment=\"1\"\u003eAirGreen\u003c\/strong\u003e, we ensure that your installation is carried out \u003cstrong data-mce-fragment=\"1\"\u003eto the highest standards\u003c\/strong\u003e, guaranteeing the best performance from your heat pump.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eThe unit comes with a \u003cstrong data-mce-fragment=\"1\"\u003e10-year warranty on the compressor and parts\u003c\/strong\u003e, offering complete peace of mind for years to come.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eAdditionally, thanks to \u003cstrong data-mce-fragment=\"1\"\u003eHydro-Québec’s LogisVert program\u003c\/strong\u003e, you may be eligible for a \u003cstrong data-mce-fragment=\"1\"\u003e$2,640 rebate\u003c\/strong\u003e, making this investment even more attractive.\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eWhy choose AirGreen for your Zephyr Series 25 heat pump installation?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003ePurchasing a \u003cstrong data-mce-fragment=\"1\"\u003ehigh-performance heat pump\u003c\/strong\u003e isn’t enough—it must also be \u003cstrong data-mce-fragment=\"1\"\u003eprofessionally installed\u003c\/strong\u003e to maximize efficiency. \u003cstrong data-mce-fragment=\"1\"\u003eAirGreen\u003c\/strong\u003e, a \u003cstrong data-mce-fragment=\"1\"\u003eheating and cooling specialist in Montreal, Laval, Longueuil, the South Shore, and the North Shore\u003c\/strong\u003e, guarantees:\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e✅ \u003cstrong data-mce-fragment=\"1\"\u003eProfessional installation\u003c\/strong\u003e that meets the highest industry standards.\u003cbr data-mce-fragment=\"1\"\u003e✅ \u003cstrong data-mce-fragment=\"1\"\u003eA responsive after-sales service\u003c\/strong\u003e to ensure your system runs smoothly.\u003cbr data-mce-fragment=\"1\"\u003e✅ \u003cstrong data-mce-fragment=\"1\"\u003ePersonalized advice\u003c\/strong\u003e to optimize your comfort and energy savings.\u003cbr data-mce-fragment=\"1\"\u003e✅ \u003cstrong data-mce-fragment=\"1\"\u003eSupport for rebate applications\u003c\/strong\u003e and financing options.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWith \u003cstrong data-mce-fragment=\"1\"\u003eAirGreen\u003c\/strong\u003e, you’re choosing a \u003cstrong data-mce-fragment=\"1\"\u003etrusted company\u003c\/strong\u003e that prioritizes quality, efficiency, and customer satisfaction.\u003c\/p\u003e\n\u003chr data-mce-fragment=\"1\"\u003e\n\u003ch3 data-mce-fragment=\"1\"\u003e\u003cstrong data-mce-fragment=\"1\"\u003eConclusion: An essential heat pump for total comfort\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-mce-fragment=\"1\"\u003eBy combining \u003cstrong data-mce-fragment=\"1\"\u003ehigh performance, durability, and energy savings\u003c\/strong\u003e, the \u003cstrong data-mce-fragment=\"1\"\u003eZephyr Series 25 Wall-Mounted Heat Pump | 24,000 BTU R-454B\u003c\/strong\u003e is an \u003cstrong data-mce-fragment=\"1\"\u003eideal choice for Quebec homes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eWhether you need \u003cstrong data-mce-fragment=\"1\"\u003eefficient heating for winter\u003c\/strong\u003e or \u003cstrong data-mce-fragment=\"1\"\u003epowerful cooling for hot summers\u003c\/strong\u003e, this system delivers \u003cstrong data-mce-fragment=\"1\"\u003etop-tier performance\u003c\/strong\u003e while remaining \u003cstrong data-mce-fragment=\"1\"\u003eaffordable and eco-friendly\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eDon’t let \u003cstrong data-mce-fragment=\"1\"\u003eunpredictable weather\u003c\/strong\u003e affect your comfort. \u003cstrong data-mce-fragment=\"1\"\u003eContact AirGreen today\u003c\/strong\u003e for a quote and discover how this heat pump can transform your daily life!\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":49795707830564,"sku":"ZE-24CB25O","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEMURALEZEPHYRR454B24000BTUMONTREAL_LAVAL_LONGUEUIL_RIVESUD_RIVENORD.png?v=1762180139"},{"product_id":"thermopompe-murale-zephyr-cb22-r32-9000-btu-115v","title":"ZEPHYR CB22 R32 Wall Heat Pump | 9000 BTU 115V","description":"\u003ch1 data-start=\"0\" data-end=\"62\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2\" data-end=\"62\"\u003eZephyr ZE-09DB22 R32 Wall-Mounted Heat Pump – 9,000 BTU 115V\u003c\/strong\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"64\" data-end=\"732\"\u003eThe \u003cstrong data-start=\"67\" data-end=\"120\"\u003eZephyr ZE-09DB22 R32 9,000 BTU wall-mounted heat pump\u003c\/strong\u003e is a compact, practical, and efficient HVAC solution for owners who want to cool and heat a specific room, a bedroom, an office, a small condo, a closed family room, or a residential space where a high-capacity unit would simply be too powerful. At \u003cstrong data-start=\"422\" data-end=\"434\"\u003eAirGreen\u003c\/strong\u003e, we recommend this type of device when the need is clear: to achieve \u003cstrong data-start=\"514\" data-end=\"532\"\u003estable comfort\u003c\/strong\u003e, good heating performance, easier installation thanks to the \u003cstrong data-start=\"622\" data-end=\"630\"\u003e115V\u003c\/strong\u003e power supply, and a wall-mounted solution suited to the realities of houses, condos, and small spaces in Greater Montreal.\u003c\/p\u003e\n\u003cp data-start=\"734\" data-end=\"1390\"\u003eThis model is part of the \u003cstrong data-start=\"768\" data-end=\"783\"\u003eZephyr CB22\u003c\/strong\u003e series, operating with \u003cstrong data-start=\"801\" data-end=\"820\"\u003eR32 refrigerant\u003c\/strong\u003e. It stands out for its cooling capacity of \u003cstrong data-start=\"876\" data-end=\"891\"\u003e9,000 BTU\/h\u003c\/strong\u003e, heating capacity of \u003cstrong data-start=\"921\" data-end=\"946\"\u003e12,000 BTU\/h at 8.3 °C\u003c\/strong\u003e, heating operation down to \u003cstrong data-start=\"988\" data-end=\"998\"\u003e-25 °C\u003c\/strong\u003e, cooling possible down to \u003cstrong data-start=\"1034\" data-end=\"1054\"\u003e-15 °C outdoor\u003c\/strong\u003e, as well as many comfort features such as \u003cstrong data-start=\"1111\" data-end=\"1124\"\u003enight mode\u003c\/strong\u003e, \u003cstrong data-start=\"1129\" data-end=\"1145\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"1150\" data-end=\"1164\"\u003eiFeel mode\u003c\/strong\u003e, \u003cstrong data-start=\"1169\" data-end=\"1189\"\u003equick start\u003c\/strong\u003e, \u003cstrong data-start=\"1194\" data-end=\"1208\"\u003eTurbo mode\u003c\/strong\u003e, \u003cstrong data-start=\"1213\" data-end=\"1238\"\u003eautomatic defrost\u003c\/strong\u003e, and \u003cstrong data-start=\"1245\" data-end=\"1270\"\u003eautomatic cleaning\u003c\/strong\u003e. These features are listed in the Zephyr CB22 brochure used for this model.\u003c\/p\u003e\n\u003cp data-start=\"1392\" data-end=\"1836\"\u003eThe Zephyr ZE-09DB22 is not a heat pump designed for a large open area or a whole floor heavily exposed to the sun. It is rather designed to provide \u003cstrong data-start=\"1555\" data-end=\"1572\"\u003etargeted comfort\u003c\/strong\u003e in a well-defined zone. This is precisely what makes it interesting: when a customer is looking for a discreet, relatively compact machine capable of heating and cooling a room without oversizing the system, this model can become an excellent choice.\u003c\/p\u003e\n\u003cp data-start=\"1838\" data-end=\"2367\"\u003eAt AirGreen, we know that a \u003cstrong data-start=\"1894\" data-end=\"1907\"\u003e9,000 BTU\u003c\/strong\u003e wall-mounted heat pump must be selected precisely. A unit that is too small will run constantly and struggle to maintain comfort. A unit that is too large risks cooling too quickly without properly dehumidifying the air. For this reason, we always assess the area, insulation, ceiling height, windows, solar orientation, air circulation, building type, and customer expectations before confirming the installation.\u003c\/p\u003e\n\u003ch2 data-start=\"2369\" data-end=\"2431\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2372\" data-end=\"2431\"\u003eThe important technical specifications to know\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2433\" data-end=\"2534\"\u003eFor the model \u003cstrong data-start=\"2448\" data-end=\"2468\"\u003eZephyr ZE-09DB22\u003c\/strong\u003e, the main brochure information is as follows:\u003c\/p\u003e\n\u003cp data-start=\"2536\" data-end=\"3822\"\u003e• \u003cstrong data-start=\"2538\" data-end=\"2557\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"2557\" data-end=\"2560\"\u003e• \u003cstrong data-start=\"2562\" data-end=\"2578\"\u003eSeries: CB22\u003c\/strong\u003e\u003cbr data-start=\"2578\" data-end=\"2581\"\u003e• \u003cstrong data-start=\"2583\" data-end=\"2605\"\u003eModel: ZE-09DB22\u003c\/strong\u003e\u003cbr data-start=\"2605\" data-end=\"2608\"\u003e• \u003cstrong data-start=\"2610\" data-end=\"2639\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"2639\" data-end=\"2642\"\u003e• \u003cstrong data-start=\"2644\" data-end=\"2697\"\u003eCooling capacity at 35 °C: 9,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2697\" data-end=\"2700\"\u003e• \u003cstrong data-start=\"2702\" data-end=\"2751\"\u003eHeating capacity at 8.3 °C: 12,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2751\" data-end=\"2754\"\u003e• \u003cstrong data-start=\"2756\" data-end=\"2777\"\u003eRefrigerant: R32\u003c\/strong\u003e\u003cbr data-start=\"2777\" data-end=\"2780\"\u003e• \u003cstrong data-start=\"2782\" data-end=\"2798\"\u003eSEER2: 20.0\u003c\/strong\u003e\u003cbr data-start=\"2798\" data-end=\"2801\"\u003e• \u003cstrong data-start=\"2803\" data-end=\"2821\"\u003eHSPF2 IV: 8.0\u003c\/strong\u003e\u003cbr data-start=\"2821\" data-end=\"2824\"\u003e• \u003cstrong data-start=\"2826\" data-end=\"2847\"\u003eEER2: 10.4 Btu\/W\u003c\/strong\u003e\u003cbr data-start=\"2847\" data-end=\"2850\"\u003e• \u003cstrong data-start=\"2852\" data-end=\"2884\"\u003eHeating COP at 8.3 °C: 3.4\u003c\/strong\u003e\u003cbr data-start=\"2884\" data-end=\"2887\"\u003e• \u003cstrong data-start=\"2889\" data-end=\"2911\"\u003eCOP at -15 °C: 1.9\u003c\/strong\u003e\u003cbr data-start=\"2911\" data-end=\"2914\"\u003e• \u003cstrong data-start=\"2916\" data-end=\"2942\"\u003eEnergy Star V6.1: No\u003c\/strong\u003e\u003cbr data-start=\"2942\" data-end=\"2945\"\u003e• \u003cstrong data-start=\"2947\" data-end=\"2988\"\u003eIndoor airflow: 253 to 400 CFM\u003c\/strong\u003e\u003cbr data-start=\"2988\" data-end=\"2991\"\u003e• \u003cstrong data-start=\"2993\" data-end=\"3060\"\u003eIndoor sound pressure: 46 \/ 40 \/ 32.5 \/ 30 \/ 28 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"3060\" data-end=\"3063\"\u003e• \u003cstrong data-start=\"3065\" data-end=\"3110\"\u003eOutdoor sound pressure: 52 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"3110\" data-end=\"3113\"\u003e• \u003cstrong data-start=\"3115\" data-end=\"3149\"\u003eVoltage: 115V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"3149\" data-end=\"3152\"\u003e• \u003cstrong data-start=\"3154\" data-end=\"3199\"\u003eNominal cooling current: 10.5 A\u003c\/strong\u003e\u003cbr data-start=\"3199\" data-end=\"3202\"\u003e• \u003cstrong data-start=\"3204\" data-end=\"3244\"\u003eNominal heating current: 9.4 A\u003c\/strong\u003e\u003cbr data-start=\"3244\" data-end=\"3247\"\u003e• \u003cstrong data-start=\"3249\" data-end=\"3265\"\u003eMCA: 15.6 A\u003c\/strong\u003e\u003cbr data-start=\"3265\" data-end=\"3268\"\u003e• \u003cstrong data-start=\"3270\" data-end=\"3284\"\u003eMOP: 20 A\u003c\/strong\u003e\u003cbr data-start=\"3284\" data-end=\"3287\"\u003e• \u003cstrong data-start=\"3289\" data-end=\"3352\"\u003eRequired communication wire: 4\/14 copper multi-strand 600V\u003c\/strong\u003e\u003cbr data-start=\"3352\" data-end=\"3355\"\u003e• \u003cstrong data-start=\"3357\" data-end=\"3387\"\u003eCompressor: GMCC rotary\u003c\/strong\u003e\u003cbr data-start=\"3387\" data-end=\"3390\"\u003e• \u003cstrong data-start=\"3392\" data-end=\"3435\"\u003eExpansion device: capillary tube\u003c\/strong\u003e\u003cbr data-start=\"3435\" data-end=\"3438\"\u003e• \u003cstrong data-start=\"3440\" data-end=\"3469\"\u003eIndoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"3469\" data-end=\"3472\"\u003e• \u003cstrong data-start=\"3474\" data-end=\"3503\"\u003eOutdoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"3503\" data-end=\"3506\"\u003e• \u003cstrong data-start=\"3508\" data-end=\"3539\"\u003eLiquid piping: 1\/4 in\u003c\/strong\u003e\u003cbr data-start=\"3539\" data-end=\"3542\"\u003e• \u003cstrong data-start=\"3544\" data-end=\"3571\"\u003eGas piping: 3\/8 in\u003c\/strong\u003e\u003cbr data-start=\"3571\" data-end=\"3574\"\u003e• \u003cstrong data-start=\"3576\" data-end=\"3626\"\u003eMinimum-maximum piping length: 10 to 65 feet\u003c\/strong\u003e\u003cbr data-start=\"3626\" data-end=\"3629\"\u003e• \u003cstrong data-start=\"3631\" data-end=\"3668\"\u003eMaximum elevation difference: 50 feet\u003c\/strong\u003e\u003cbr data-start=\"3668\" data-end=\"3671\"\u003e• \u003cstrong data-start=\"3673\" data-end=\"3709\"\u003ePrecharge length: 25 feet\u003c\/strong\u003e\u003cbr data-start=\"3709\" data-end=\"3712\"\u003e• \u003cstrong data-start=\"3714\" data-end=\"3757\"\u003eZephyr basic warranty: 10 years parts\u003c\/strong\u003e\u003cbr data-start=\"3757\" data-end=\"3760\"\u003e• \u003cstrong data-start=\"3762\" data-end=\"3822\"\u003eLabor warranty: available according to the distributor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3824\" data-end=\"3979\"\u003eThe brochure presents the dimensions in \u003cstrong data-start=\"3870\" data-end=\"3883\"\u003eW × H × D\u003c\/strong\u003e format. For easier reading during installation, here are the dimensions in \u003cstrong data-start=\"3964\" data-end=\"3977\"\u003eW × D × H\u003c\/strong\u003e format:\u003c\/p\u003e\n\u003cp data-start=\"3981\" data-end=\"4080\"\u003e• \u003cstrong data-start=\"3983\" data-end=\"4029\"\u003eIndoor unit: 33.44 × 8.06 × 11.56 in\u003c\/strong\u003e\u003cbr data-start=\"4029\" data-end=\"4032\"\u003e• \u003cstrong data-start=\"4034\" data-end=\"4080\"\u003eOutdoor unit: 28.13 × 9.50 × 21.25 in\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4082\" data-end=\"4572\"\u003eThese dimensions are important, especially in condos, bedrooms, offices, or rooms where wall space is limited. An indoor unit of \u003cstrong data-start=\"4234\" data-end=\"4257\"\u003e33.44 inches wide\u003c\/strong\u003e requires a sufficiently clear wall, with enough space around it to ensure good air distribution. The outdoor unit, more compact than those of higher capacity models, sometimes facilitates installation on a wall bracket, balcony, side yard, or outdoor base, depending on the building constraints.\u003c\/p\u003e\n\u003ch2 data-start=\"4574\" data-end=\"4647\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4577\" data-end=\"4647\"\u003eA 9,000 BTU heat pump designed for small and medium spaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4649\" data-end=\"5006\"\u003eThe \u003cstrong data-start=\"4652\" data-end=\"4682\"\u003eZephyr ZE-09DB22 9,000 BTU\u003c\/strong\u003e is generally suitable for closed or semi-open rooms where the heat load remains reasonable. It can be relevant for a master bedroom, a home office, a compact living room, a basement room, a small condo, or a space where the customer wants to control the temperature independently.\u003c\/p\u003e\n\u003cp data-start=\"5008\" data-end=\"5425\"\u003eIn a house in \u003cstrong data-start=\"5026\" data-end=\"5038\"\u003eMontreal\u003c\/strong\u003e, this type of device can be very useful in an upstairs bedroom that gets too hot in the summer. In \u003cstrong data-start=\"5140\" data-end=\"5149\"\u003eLaval\u003c\/strong\u003e, it can meet the needs of a home office exposed to the sun. On the \u003cstrong data-start=\"5226\" data-end=\"5238\"\u003eSouth Shore\u003c\/strong\u003e, it can suit a smaller living space or an annex. On the \u003cstrong data-start=\"5311\" data-end=\"5324\"\u003eNorth Shore\u003c\/strong\u003e, it can be used in a closed room where electric heating is expensive or uncomfortable.\u003c\/p\u003e\n\u003cp data-start=\"5427\" data-end=\"5813\"\u003eHowever, we always avoid recommending capacity based solely on area. A room of the same size may require different capacity depending on its insulation, orientation, number of windows, wind exposure, or daily use. \u003cstrong data-start=\"5694\" data-end=\"5734\"\u003eProper sizing is essential\u003c\/strong\u003e to achieve stable comfort and avoid cycles that are too short or too long.\u003c\/p\u003e\n\u003cp data-start=\"5815\" data-end=\"6162\"\u003eA \u003cstrong data-start=\"5834\" data-end=\"5847\"\u003e9,000 BTU\u003c\/strong\u003e heat pump is often interesting when a targeted solution is desired, but it is not intended to replace a central system for an entire house. At AirGreen, we take the time to explain this nuance because it helps avoid unrealistic expectations and offers a solution truly adapted to the building.\u003c\/p\u003e\n\u003ch2 data-start=\"6164\" data-end=\"6246\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6167\" data-end=\"6246\"\u003eR32 refrigerant: a modern choice for new HVAC installations\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"6248\" data-end=\"6501\"\u003eThe Zephyr ZE-09DB22 operates with \u003cstrong data-start=\"6282\" data-end=\"6301\"\u003eR32 refrigerant\u003c\/strong\u003e. This refrigerant is increasingly used in modern wall-mounted heat pumps. It allows manufacturers to design newer equipment adapted to the new HVAC market requirements.\u003c\/p\u003e\n\u003cp data-start=\"6503\" data-end=\"6858\"\u003eFor the client, the type of refrigerant may seem technical, but it directly influences installation methods. A heat pump with \u003cstrong data-start=\"6644\" data-end=\"6651\"\u003eR32\u003c\/strong\u003e must be installed with rigor: flares must be clean, fittings must be tight, lines must be properly tested, and vacuum pulling must be done thoroughly.\u003c\/p\u003e\n\u003cp data-start=\"6860\" data-end=\"7214\"\u003eAt AirGreen, we place great importance on these steps. A modern heat pump can perform well on paper, but if the installation is sloppy, the result can be disappointing: loss of performance, noise, leaks, poor drainage, or reduced lifespan. \u003cstrong data-start=\"7137\" data-end=\"7214\"\u003eThe quality of the installation is as important as the choice of model.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"7216\" data-end=\"7298\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"7219\" data-end=\"7298\"\u003eEnergy performance: understanding the numbers without isolating them from the project\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"7300\" data-end=\"7545\"\u003eThe technical sheet indicates a \u003cstrong data-start=\"7330\" data-end=\"7347\"\u003eSEER2 of 20.0\u003c\/strong\u003e, an \u003cstrong data-start=\"7352\" data-end=\"7371\"\u003eHSPF2 IV of 8.0\u003c\/strong\u003e, an \u003cstrong data-start=\"7376\" data-end=\"7398\"\u003eEER2 of 10.4 Btu\/W\u003c\/strong\u003e, and a \u003cstrong data-start=\"7405\" data-end=\"7441\"\u003eheating COP at 8.3 °C of 3.4\u003c\/strong\u003e. These values provide an indication of the heat pump’s efficiency in air conditioning and heating.\u003c\/p\u003e\n\u003cp data-start=\"7547\" data-end=\"7849\"\u003eThe \u003cstrong data-start=\"7550\" data-end=\"7559\"\u003eSEER2\u003c\/strong\u003e represents the seasonal efficiency in air conditioning. The \u003cstrong data-start=\"7617\" data-end=\"7626\"\u003eHSPF2\u003c\/strong\u003e gives an idea of heating efficiency over a season. The \u003cstrong data-start=\"7690\" data-end=\"7698\"\u003eEER2\u003c\/strong\u003e measures efficiency in air conditioning under specific conditions. The \u003cstrong data-start=\"7769\" data-end=\"7776\"\u003eCOP\u003c\/strong\u003e indicates the ratio between heat produced and electricity consumed.\u003c\/p\u003e\n\u003cp data-start=\"7851\" data-end=\"8222\"\u003eFor an owner, the important thing is to understand that these figures must be read in the context of the building. A heat pump installed in a well-insulated room, with good air circulation and an appropriate location, will generally offer better comfort than a device installed in a poorly chosen spot, even if the technical figures seem good.\u003c\/p\u003e\n\u003cp data-start=\"8224\" data-end=\"8657\"\u003eIt should also be noted that the sheet indicates \u003cstrong data-start=\"8265\" data-end=\"8291\"\u003eEnergy Star V6.1: No\u003c\/strong\u003e for the \u003cstrong data-start=\"8307\" data-end=\"8320\"\u003eZE-09DB22\u003c\/strong\u003e model. This does not mean the device is not interesting, but it should be considered if the customer is specifically looking for a heat pump eligible for certain energy efficiency programs. Before discussing subsidies, we always recommend checking the current program criteria and the exact model installed.\u003c\/p\u003e\n\u003ch2 data-start=\"8659\" data-end=\"8733\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"8662\" data-end=\"8733\"\u003eHeating down to -25 °C: what it means in Quebec’s climate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"8735\" data-end=\"8979\"\u003eThe Zephyr CB22 brochure states that the heat pump can operate in heating mode down to an outdoor temperature of \u003cstrong data-start=\"8854\" data-end=\"8864\"\u003e-25 °C\u003c\/strong\u003e. This is an important point for Quebec winters. However, it is necessary to clearly explain what this means.\u003c\/p\u003e\n\u003cp data-start=\"8981\" data-end=\"9188\"\u003eA heat pump can continue to operate at low temperatures, but its heating capacity generally decreases as the cold intensifies. For the \u003cstrong data-start=\"9145\" data-end=\"9158\"\u003eZE-09DB22\u003c\/strong\u003e, the technical sheet indicates:\u003c\/p\u003e\n\u003cp data-start=\"9190\" data-end=\"9362\"\u003e• \u003cstrong data-start=\"9192\" data-end=\"9237\"\u003eNominal capacity at -8.3 °C: 7,200 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"9237\" data-end=\"9240\"\u003e• \u003cstrong data-start=\"9242\" data-end=\"9286\"\u003eMaximum capacity at -15 °C: 6,100 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"9286\" data-end=\"9289\"\u003e• \u003cstrong data-start=\"9291\" data-end=\"9335\"\u003eMaximum capacity at -20 °C: 5,800 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"9335\" data-end=\"9338\"\u003e• \u003cstrong data-start=\"9340\" data-end=\"9362\"\u003eCOP at -15 °C: 1.9\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"9364\" data-end=\"9720\"\u003eThis data is very useful to know what to expect in winter. In a well-insulated room, the heat pump can provide a good portion of the necessary heating for much of the season. In a more exposed room, poorly insulated or with large windows, supplementary heating may still be needed on the coldest days.\u003c\/p\u003e\n\u003cp data-start=\"9722\" data-end=\"9989\"\u003eAt AirGreen, we always prefer to explain this point before installation. \u003cstrong data-start=\"9802\" data-end=\"9880\"\u003eA wall-mounted heat pump can reduce the use of electric baseboards\u003c\/strong\u003e, improve comfort, and stabilize temperature, but it must be intelligently integrated into the building.\u003c\/p\u003e\n\u003ch2 data-start=\"9991\" data-end=\"10068\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"9994\" data-end=\"10068\"\u003eAir conditioning down to -15 °C outside: useful in certain contexts\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"10070\" data-end=\"10638\"\u003eThe brochure also states that the air conditioning mode can cool down to an outdoor temperature of \u003cstrong data-start=\"10180\" data-end=\"10190\"\u003e-15 °C\u003c\/strong\u003e. For standard residential use, this information is not always a priority, as air conditioning is mainly used during hot periods. However, it can be interesting in certain contexts: technical rooms, small businesses, spaces with many electronic devices, rooms very exposed to the sun, or buildings where internal heat remains high even when the outdoor temperature is cooler.\u003c\/p\u003e\n\u003cp data-start=\"10640\" data-end=\"10953\"\u003eThe cooling operating range is indicated as \u003cstrong data-start=\"10702\" data-end=\"10720\"\u003e-15 °C to 48 °C\u003c\/strong\u003e, providing good usage flexibility. In summer, a capacity of \u003cstrong data-start=\"10809\" data-end=\"10824\"\u003e9,000 BTU\/h\u003c\/strong\u003e can be perfectly suited to stabilize a closed room, reduce perceived humidity, and improve daily comfort.\u003c\/p\u003e\n\u003ch2 data-start=\"10955\" data-end=\"11011\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10958\" data-end=\"11011\"\u003eInstallation: the details that make the difference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"11013\" data-end=\"11203\"\u003eA good wall-mounted heat pump installation always starts with good planning. For the \u003cstrong data-start=\"11113\" data-end=\"11133\"\u003eZephyr ZE-09DB22\u003c\/strong\u003e, several technical details must be verified before work begins.\u003c\/p\u003e\n\u003ch2 data-start=\"11205\" data-end=\"11245\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11208\" data-end=\"11245\"\u003eIndoor unit location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"11247\" data-end=\"11506\"\u003eThe indoor unit should be placed to distribute air well without blowing directly on occupants for long periods. The airflow of this model ranges between \u003cstrong data-start=\"11431\" data-end=\"11449\"\u003e253 and 400 CFM\u003c\/strong\u003e, which is suitable for a reasonably sized room.\u003c\/p\u003e\n\u003cp data-start=\"11508\" data-end=\"11885\"\u003eWe analyze the shape of the room, the position of the bed, desk, sofa, windows, doors, stairs, and exterior walls. In many condos in Montreal or Longueuil, wall space can be limited by closets, windows, curtains, or concrete walls. Good planning results in a more aesthetic and efficient outcome.\u003c\/p\u003e\n\u003ch2 data-start=\"11887\" data-end=\"11927\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11890\" data-end=\"11927\"\u003eOutdoor unit location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"11929\" data-end=\"12220\"\u003eThe outdoor unit must be installed in a stable, accessible, and well-ventilated location. The indicated outdoor sound pressure level is \u003cstrong data-start=\"12070\" data-end=\"12082\"\u003e52 dB(A)\u003c\/strong\u003e, which remains reasonable, but the location should still be chosen carefully to respect neighbors and avoid vibrations.\u003c\/p\u003e\n\u003cp data-start=\"12222\" data-end=\"12534\"\u003eOn a balcony, backyard, side wall, or ground base, we check clearances, water drainage, snow, ice, vibrations, and future access for maintenance. An outdoor unit that is too low or poorly protected can be exposed to snow accumulation during the Quebec winter.\u003c\/p\u003e\n\u003ch2 data-start=\"12536\" data-end=\"12566\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"12539\" data-end=\"12566\"\u003e1\/4 - 3\/8 inch piping\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"12568\" data-end=\"12760\"\u003eThe ZE-09DB22 uses \u003cstrong data-start=\"12604\" data-end=\"12622\"\u003e1\/4 inch liquid\u003c\/strong\u003e and \u003cstrong data-start=\"12626\" data-end=\"12640\"\u003e3\/8 inch gas\u003c\/strong\u003e piping. This configuration is very common for small wall-mounted heat pumps, but it must still be respected.\u003c\/p\u003e\n\u003cp data-start=\"12762\" data-end=\"13133\"\u003eWhen replacing an old machine, never assume existing lines are compatible. We check the diameter, line condition, type of old refrigerant, total length, and the possibility to reuse or replace the piping. \u003cstrong data-start=\"13032\" data-end=\"13133\"\u003eA poor line match can affect the device’s performance and reliability.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"13135\" data-end=\"13404\"\u003eThe brochure indicates a total piping length of \u003cstrong data-start=\"13192\" data-end=\"13209\"\u003e10 to 65 feet\u003c\/strong\u003e, a maximum elevation of \u003cstrong data-start=\"13241\" data-end=\"13253\"\u003e50 feet\u003c\/strong\u003e, and a precharge length of \u003cstrong data-start=\"13293\" data-end=\"13305\"\u003e25 feet\u003c\/strong\u003e. This information is important to confirm project feasibility before installation.\u003c\/p\u003e\n\u003ch2 data-start=\"13406\" data-end=\"13441\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"13409\" data-end=\"13441\"\u003e115V power supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"13443\" data-end=\"13715\"\u003eOne interesting point of this model is its power supply of \u003cstrong data-start=\"13507\" data-end=\"13531\"\u003e115V, 60 Hz, 1 phase\u003c\/strong\u003e. For some projects, this can simplify planning compared to 208V \/ 230V models. However, this does not mean the device can be connected just any way.\u003c\/p\u003e\n\u003cp data-start=\"13717\" data-end=\"14020\"\u003eThe datasheet indicates a \u003cstrong data-start=\"13737\" data-end=\"13754\"\u003eMCA of 15.6 A\u003c\/strong\u003e and a \u003cstrong data-start=\"13761\" data-end=\"13776\"\u003eMOP of 20 A\u003c\/strong\u003e. Therefore, appropriate electrical protection must be planned and the available circuit verified. At AirGreen, we always validate the electrical panel, wire gauge, circuit breaker, electrical routing, and installation compliance.\u003c\/p\u003e\n\u003cp data-start=\"14022\" data-end=\"14241\"\u003eIn older homes in Montreal, Laval, or Longueuil, this check is especially important. A serious installation price must always take into account the actual condition of the electrical installation.\u003c\/p\u003e\n\u003ch2 data-start=\"14243\" data-end=\"14280\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"14246\" data-end=\"14280\"\u003eBuilt-in comfort functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"14282\" data-end=\"14414\"\u003eThe Zephyr ZE-09DB22 offers several practical features to enhance daily comfort. The brochure highlights in particular:\u003c\/p\u003e\n\u003cp data-start=\"14416\" data-end=\"15083\"\u003e• \u003cstrong data-start=\"14418\" data-end=\"14431\"\u003eNight mode\u003c\/strong\u003e\u003cbr data-start=\"14431\" data-end=\"14434\"\u003e• \u003cstrong data-start=\"14436\" data-end=\"14452\"\u003eSilent mode\u003c\/strong\u003e\u003cbr data-start=\"14452\" data-end=\"14455\"\u003e• \u003cstrong data-start=\"14457\" data-end=\"14471\"\u003eiFeel mode\u003c\/strong\u003e\u003cbr data-start=\"14471\" data-end=\"14474\"\u003e• \u003cstrong data-start=\"14476\" data-end=\"14496\"\u003eQuick start\u003c\/strong\u003e\u003cbr data-start=\"14496\" data-end=\"14499\"\u003e• \u003cstrong data-start=\"14501\" data-end=\"14518\"\u003e24-hour timer\u003c\/strong\u003e\u003cbr data-start=\"14518\" data-end=\"14521\"\u003e• \u003cstrong data-start=\"14523\" data-end=\"14545\"\u003eTwo-sided drain\u003c\/strong\u003e\u003cbr data-start=\"14545\" data-end=\"14548\"\u003e• \u003cstrong data-start=\"14550\" data-end=\"14574\"\u003eBase heating\u003c\/strong\u003e\u003cbr data-start=\"14574\" data-end=\"14577\"\u003e• \u003cstrong data-start=\"14579\" data-end=\"14607\"\u003eCompressor heating\u003c\/strong\u003e\u003cbr data-start=\"14607\" data-end=\"14610\"\u003e• \u003cstrong data-start=\"14612\" data-end=\"14654\"\u003eSelf-adaptive voltage technology\u003c\/strong\u003e\u003cbr data-start=\"14654\" data-end=\"14657\"\u003e• \u003cstrong data-start=\"14659\" data-end=\"14688\"\u003eFireproof electrical box\u003c\/strong\u003e\u003cbr data-start=\"14688\" data-end=\"14691\"\u003e• \u003cstrong data-start=\"14693\" data-end=\"14720\"\u003eAutomatic oscillation\u003c\/strong\u003e\u003cbr data-start=\"14720\" data-end=\"14723\"\u003e• \u003cstrong data-start=\"14725\" data-end=\"14736\"\u003e4D mode\u003c\/strong\u003e\u003cbr data-start=\"14736\" data-end=\"14739\"\u003e• \u003cstrong data-start=\"14741\" data-end=\"14781\"\u003e5 indoor fan speeds\u003c\/strong\u003e\u003cbr data-start=\"14781\" data-end=\"14784\"\u003e• \u003cstrong data-start=\"14786\" data-end=\"14815\"\u003eLED wireless remote control\u003c\/strong\u003e\u003cbr data-start=\"14815\" data-end=\"14818\"\u003e• \u003cstrong data-start=\"14820\" data-end=\"14839\"\u003eLED dimmer\u003c\/strong\u003e\u003cbr data-start=\"14839\" data-end=\"14842\"\u003e• \u003cstrong data-start=\"14844\" data-end=\"14876\"\u003eAutomatic 8 °C heating\u003c\/strong\u003e\u003cbr data-start=\"14876\" data-end=\"14879\"\u003e• \u003cstrong data-start=\"14881\" data-end=\"14909\"\u003eReversible drain pipe\u003c\/strong\u003e\u003cbr data-start=\"14909\" data-end=\"14912\"\u003e• \u003cstrong data-start=\"14914\" data-end=\"14932\"\u003eTurbo function\u003c\/strong\u003e\u003cbr data-start=\"14932\" data-end=\"14935\"\u003e• \u003cstrong data-start=\"14937\" data-end=\"14962\"\u003eAutomatic defrost\u003c\/strong\u003e\u003cbr data-start=\"14962\" data-end=\"14965\"\u003e• \u003cstrong data-start=\"14967\" data-end=\"14992\"\u003eAutomatic cleaning\u003c\/strong\u003e\u003cbr data-start=\"14992\" data-end=\"14995\"\u003e• \u003cstrong data-start=\"14997\" data-end=\"15033\"\u003eDiffuser position memory\u003c\/strong\u003e\u003cbr data-start=\"15033\" data-end=\"15036\"\u003e• \u003cstrong data-start=\"15038\" data-end=\"15083\"\u003eHeated chassis for the outdoor base\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"15085\" data-end=\"15462\"\u003eThe \u003cstrong data-start=\"15088\" data-end=\"15099\"\u003e4D mode\u003c\/strong\u003e and \u003cstrong data-start=\"15105\" data-end=\"15132\"\u003eautomatic oscillation\u003c\/strong\u003e are particularly useful for better air distribution in the room. Good air distribution helps avoid cold or overly warm spots. For a bedroom or office, the \u003cstrong data-start=\"15327\" data-end=\"15343\"\u003esilent mode\u003c\/strong\u003e and \u003cstrong data-start=\"15350\" data-end=\"15363\"\u003enight mode\u003c\/strong\u003e can also be very appreciated, especially when the unit runs for several hours.\u003c\/p\u003e\n\u003cp data-start=\"15464\" data-end=\"15758\"\u003eThe \u003cstrong data-start=\"15467\" data-end=\"15481\"\u003eiFeel mode\u003c\/strong\u003e is also interesting because it helps the unit better adjust comfort based on the temperature sensed near the remote control. In a small room, this function can improve comfort accuracy, especially if the indoor unit is installed higher on the wall.\u003c\/p\u003e\n\u003ch2 data-start=\"15760\" data-end=\"15827\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"15763\" data-end=\"15827\"\u003eInverter Comfort: Stability and Better Controlled Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"15829\" data-end=\"16150\"\u003eThe brochure explains that variable frequency technology allows the heat pump to adjust its power in real time. This is an important point for comfort. Unlike a traditional unit that starts and stops abruptly, an \u003cstrong data-start=\"16088\" data-end=\"16100\"\u003eInverter\u003c\/strong\u003e heat pump can modulate its operation according to demand.\u003c\/p\u003e\n\u003cp data-start=\"16152\" data-end=\"16404\"\u003eIn practice, this helps reduce temperature fluctuations, improve comfort, and limit unnecessary cycles. Once the desired temperature is reached, the unit can operate more gently to maintain the indoor environment.\u003c\/p\u003e\n\u003cp data-start=\"16406\" data-end=\"16717\"\u003eFor a customer, this often translates to a more stable comfort feeling, less start-up noise, better humidity control in cooling, and more controlled consumption. \u003cstrong data-start=\"16607\" data-end=\"16717\"\u003eHowever, actual performance always depends on the quality of the installation and proper sizing.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"16719\" data-end=\"16785\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"16722\" data-end=\"16785\"\u003eHVAC Maintenance: Maintaining Performance Year After Year\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"16787\" data-end=\"16986\"\u003eA wall-mounted heat pump must be maintained to preserve its efficiency. Even though the Zephyr ZE-09DB22 has an \u003cstrong data-start=\"16916\" data-end=\"16941\"\u003eautomatic cleaning\u003c\/strong\u003e function, this does not replace regular maintenance.\u003c\/p\u003e\n\u003cp data-start=\"16988\" data-end=\"17017\"\u003eWe especially recommend:\u003c\/p\u003e\n\u003cp data-start=\"17019\" data-end=\"17468\"\u003e• \u003cstrong data-start=\"17021\" data-end=\"17059\"\u003eclean the filters regularly\u003c\/strong\u003e;\u003cbr data-start=\"17060\" data-end=\"17063\"\u003e• \u003cstrong data-start=\"17065\" data-end=\"17134\"\u003eensure air flows freely around the indoor unit\u003c\/strong\u003e;\u003cbr data-start=\"17135\" data-end=\"17138\"\u003e• \u003cstrong data-start=\"17140\" data-end=\"17178\"\u003einspect the condensation drain\u003c\/strong\u003e;\u003cbr data-start=\"17179\" data-end=\"17182\"\u003e• \u003cstrong data-start=\"17184\" data-end=\"17241\"\u003eavoid obstructing the unit with furniture or curtains\u003c\/strong\u003e;\u003cbr data-start=\"17242\" data-end=\"17245\"\u003e• \u003cstrong data-start=\"17247\" data-end=\"17323\"\u003ekeep the outdoor unit clear of leaves, dust, snow, and ice\u003c\/strong\u003e;\u003cbr data-start=\"17324\" data-end=\"17327\"\u003e• \u003cstrong data-start=\"17329\" data-end=\"17390\"\u003ehave the device checked if an unusual noise appears\u003c\/strong\u003e;\u003cbr data-start=\"17391\" data-end=\"17394\"\u003e• \u003cstrong data-start=\"17396\" data-end=\"17467\"\u003eschedule professional cleaning when the exchanger becomes dirty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"17470\" data-end=\"17675\"\u003eA clean device heats better, cools better, consumes less, and lasts longer. At AirGreen, we always explain to customers the simple actions to take between professional maintenance.\u003c\/p\u003e\n\u003ch2 data-start=\"17677\" data-end=\"17742\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"17680\" data-end=\"17742\"\u003eMistakes to avoid before buying a 9,000 BTU heat pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"17744\" data-end=\"17887\"\u003eIn our experience, the most frequent mistakes do not always come from the chosen model, but rather from a poor project analysis.\u003c\/p\u003e\n\u003cp data-start=\"17889\" data-end=\"17917\"\u003eHere are the mistakes to avoid:\u003c\/p\u003e\n\u003cp data-start=\"17919\" data-end=\"18548\"\u003e• choosing a \u003cstrong data-start=\"17933\" data-end=\"17946\"\u003e9,000 BTU\u003c\/strong\u003e without checking the actual load;\u003cbr data-start=\"17978\" data-end=\"17981\"\u003e• installing the indoor unit in a corner where air circulation is poor;\u003cbr data-start=\"18046\" data-end=\"18049\"\u003e• neglecting outdoor noise in a dense area;\u003cbr data-start=\"18100\" data-end=\"18103\"\u003e• forgetting electrical verification despite the \u003cstrong data-start=\"18150\" data-end=\"18158\"\u003e115V\u003c\/strong\u003e;\u003cbr data-start=\"18159\" data-end=\"18162\"\u003e• assuming the old refrigerant lines are compatible;\u003cbr data-start=\"18229\" data-end=\"18232\"\u003e• installing the outdoor unit too close to the ground in snowy areas;\u003cbr data-start=\"18297\" data-end=\"18300\"\u003e• choosing the location just to hide the piping;\u003cbr data-start=\"18360\" data-end=\"18363\"\u003e• forgetting future access for maintenance;\u003cbr data-start=\"18404\" data-end=\"18407\"\u003e• comparing only the price without comparing installation quality;\u003cbr data-start=\"18476\" data-end=\"18479\"\u003e• ignoring the fact that this model is indicated as \u003cstrong data-start=\"18523\" data-end=\"18547\"\u003enon Energy Star V6.1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"18550\" data-end=\"18726\"\u003eAt AirGreen, we clarify these points from the start. This helps avoid unpleasant surprises, unrealistic expectations, and costly adjustments after installation.\u003c\/p\u003e\n\u003ch2 data-start=\"18728\" data-end=\"18795\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"18731\" data-end=\"18795\"\u003eWhy choose AirGreen to install the Zephyr ZE-09DB22\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"18797\" data-end=\"19070\"\u003eAirGreen is a company specialized in \u003cstrong data-start=\"18840\" data-end=\"18848\"\u003eHVAC\u003c\/strong\u003e that installs, maintains, and repairs wall-mounted, central, and multi-zone heat pumps in Greater Montreal. We regularly operate in \u003cstrong data-start=\"18991\" data-end=\"19069\"\u003eMontreal, Laval, Longueuil, on the South Shore, the North Shore, and in Montérégie\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"19072\" data-end=\"19122\"\u003eBy choosing AirGreen, customers benefit from:\u003c\/p\u003e\n\u003cp data-start=\"19124\" data-end=\"19665\"\u003e• \u003cstrong data-start=\"19126\" data-end=\"19171\"\u003ea clear assessment before the work\u003c\/strong\u003e;\u003cbr data-start=\"19172\" data-end=\"19175\"\u003e• \u003cstrong data-start=\"19177\" data-end=\"19229\"\u003ea unit selected according to the actual building\u003c\/strong\u003e;\u003cbr data-start=\"19230\" data-end=\"19233\"\u003e• \u003cstrong data-start=\"19235\" data-end=\"19291\"\u003einstallation compliant with technical requirements\u003c\/strong\u003e;\u003cbr data-start=\"19292\" data-end=\"19295\"\u003e• \u003cstrong data-start=\"19297\" data-end=\"19365\"\u003ea thorough check of electricity and piping\u003c\/strong\u003e;\u003cbr data-start=\"19366\" data-end=\"19369\"\u003e• \u003cstrong data-start=\"19371\" data-end=\"19428\"\u003ean honest explanation of winter performance\u003c\/strong\u003e;\u003cbr data-start=\"19429\" data-end=\"19432\"\u003e• \u003cstrong data-start=\"19434\" data-end=\"19472\"\u003estructured after-sales service\u003c\/strong\u003e;\u003cbr data-start=\"19473\" data-end=\"19476\"\u003e• \u003cstrong data-start=\"19478\" data-end=\"19566\"\u003ea team experienced with installations in condos, houses, plexes, and small businesses\u003c\/strong\u003e;\u003cbr data-start=\"19567\" data-end=\"19570\"\u003e• \u003cstrong data-start=\"19572\" data-end=\"19664\"\u003esupport to understand warranties, maintenance, and system limitations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"19667\" data-end=\"19977\"\u003eWe know that a heat pump is a significant investment, even when it is a compact model. Our goal is for the customer to fully understand what they are buying, why this model is recommended, how it will be installed, and how it should be used to deliver its best performance.\u003c\/p\u003e\n\u003ch2 data-start=\"19979\" data-end=\"20055\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"19982\" data-end=\"20055\"\u003eA compact, reliable HVAC solution well suited to targeted rooms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"20057\" data-end=\"20532\"\u003eThe \u003cstrong data-start=\"20060\" data-end=\"20118\"\u003eZephyr ZE-09DB22 R32 9,000 BTU 115V wall-mounted heat pump\u003c\/strong\u003e is an interesting solution for customers looking for a compact, practical device capable of heating down to \u003cstrong data-start=\"20243\" data-end=\"20253\"\u003e-25 °C\u003c\/strong\u003e. With its \u003cstrong data-start=\"20264\" data-end=\"20283\"\u003eR32 refrigerant\u003c\/strong\u003e, \u003cstrong data-start=\"20289\" data-end=\"20306\"\u003eSEER2 of 20.0\u003c\/strong\u003e, air flow of \u003cstrong data-start=\"20327\" data-end=\"20344\"\u003e253 to 400 CFM\u003c\/strong\u003e, indoor noise level as low as \u003cstrong data-start=\"20400\" data-end=\"20412\"\u003e28 dB(A)\u003c\/strong\u003e in silent mode, and built-in comfort features, it meets the needs of many residential rooms.\u003c\/p\u003e\n\u003cp data-start=\"20534\" data-end=\"20799\"\u003eHowever, it requires careful installation. The \u003cstrong data-start=\"20597\" data-end=\"20613\"\u003e1\/4 - 3\/8 inch\u003c\/strong\u003e piping, \u003cstrong data-start=\"20630\" data-end=\"20638\"\u003e115V\u003c\/strong\u003e power supply, \u003cstrong data-start=\"20643\" data-end=\"20660\"\u003e15.6 A MCA\u003c\/strong\u003e, \u003cstrong data-start=\"20665\" data-end=\"20680\"\u003e20 A MOP\u003c\/strong\u003e, outdoor clearances, drainage, and wall positioning must be verified before confirming the project.\u003c\/p\u003e\n\u003cp data-start=\"20801\" data-end=\"21189\"\u003eTo get a clear quote, check if this model suits your room, compare the Zephyr ZE-09DB22 with other wall-mounted heat pumps, or plan an installation in \u003cstrong data-start=\"20979\" data-end=\"21042\"\u003eMontreal, Laval, Longueuil, on the South Shore or the North Shore\u003c\/strong\u003e, contact \u003cstrong data-start=\"21054\" data-end=\"21066\"\u003eAirGreen\u003c\/strong\u003e. Our team will help you choose the right HVAC solution based on your building, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665925226788,"sku":"ZE-09DB22I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRCB22R32GRANDMONTREAL.png?v=1783695962"},{"product_id":"thermopompe-murale-zephyr-cb22-r32-12000-btu-115v","title":"ZEPHYR CB22 R32 Wall Heat Pump | 12000 BTU 115V","description":"\u003ch1 data-start=\"0\" data-end=\"63\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2\" data-end=\"63\"\u003eZephyr CB22 R32 ZE-12DB22 Wall-Mounted Heat Pump – 12,000 BTU\u003c\/strong\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"65\" data-end=\"194\"\u003eA 12,000 BTU wall-mounted heat pump designed for residential comfort, easy installation, and heating down to -25 °C\u003c\/p\u003e\n\u003cp data-start=\"196\" data-end=\"806\"\u003eThe \u003cstrong data-start=\"199\" data-end=\"247\"\u003eZephyr CB22 R32 ZE-12DB22 Wall-Mounted Heat Pump\u003c\/strong\u003e is aimed at owners looking for an efficient, affordable HVAC solution well suited to the common needs of a main room, a condo, a partial floor, a home office, an extension, or a medium-sized residential space. At AirGreen, we recommend this type of unit when a client wants to improve summer cooling comfort and reduce the use of traditional electric heating for much of the winter, while keeping the installation relatively simple and well controlled.\u003c\/p\u003e\n\u003cp data-start=\"808\" data-end=\"1358\"\u003eThis model is part of the \u003cstrong data-start=\"842\" data-end=\"861\"\u003eZephyr CB22 R32\u003c\/strong\u003e series, a range of wall-mounted heat pumps designed to offer stable comfort, intuitive use, and reliable performance under Quebec conditions. For the specific model \u003cstrong data-start=\"1042\" data-end=\"1055\"\u003eZE-12DB22\u003c\/strong\u003e, the brochure indicates a capacity of \u003cstrong data-start=\"1093\" data-end=\"1126\"\u003e12,000 BTU for cooling\u003c\/strong\u003e, a capacity of \u003cstrong data-start=\"1144\" data-end=\"1180\"\u003e12,000 BTU for heating at 8.3 °C\u003c\/strong\u003e, operation with \u003cstrong data-start=\"1203\" data-end=\"1222\"\u003eR32 refrigerant\u003c\/strong\u003e, a power supply of \u003cstrong data-start=\"1244\" data-end=\"1253\"\u003e115 V\u003c\/strong\u003e, and a heating range that can go down to \u003cstrong data-start=\"1309\" data-end=\"1319\"\u003e-25 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1360\" data-end=\"1902\"\u003eThis is not a machine designed to heat a very large open area like an 18,000 or 24,000 BTU unit. It is rather a device that can be very suitable for a larger bedroom, a closed living room, a small condo, an office, a well-insulated basement, or a specific area of the house where comfort is difficult to stabilize. In many projects in \u003cstrong data-start=\"1716\" data-end=\"1783\"\u003eMontreal, Laval, Longueuil, on the South Shore and the North Shore\u003c\/strong\u003e, a well-placed 12,000 BTU heat pump delivers better results than an overly powerful unit installed without analysis.\u003c\/p\u003e\n\u003cp data-start=\"1904\" data-end=\"2594\"\u003eThe \u003cstrong data-start=\"1907\" data-end=\"1920\"\u003eZE-12DB22\u003c\/strong\u003e therefore deserves a serious evaluation before installation. You need to check the area, insulation, window orientation, ceiling height, distance between the indoor and outdoor units, drainage, electrical compatibility, clearances around the outdoor unit, and air circulation in the room. At AirGreen, we know that a device can perform well on paper but deliver average results if it is poorly sized or poorly positioned. Conversely, a well-chosen wall-mounted heat pump can transform the daily comfort of a space that is too hot in summer, too cold in winter, or simply unstable from one season to another.\u003c\/p\u003e\n\u003ch2 data-start=\"2596\" data-end=\"2658\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2599\" data-end=\"2658\"\u003eThe important technical characteristics to know\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2660\" data-end=\"2767\"\u003eFor the \u003cstrong data-start=\"2668\" data-end=\"2716\"\u003eZephyr CB22 R32 ZE-12DB22 Wall-Mounted Heat Pump\u003c\/strong\u003e, the main information is as follows:\u003c\/p\u003e\n\u003cp data-start=\"2769\" data-end=\"4473\"\u003e• \u003cstrong data-start=\"2771\" data-end=\"2790\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"2790\" data-end=\"2793\"\u003e• \u003cstrong data-start=\"2795\" data-end=\"2811\"\u003eSeries: CB22\u003c\/strong\u003e\u003cbr data-start=\"2811\" data-end=\"2814\"\u003e• \u003cstrong data-start=\"2816\" data-end=\"2838\"\u003eModel: ZE-12DB22\u003c\/strong\u003e\u003cbr data-start=\"2838\" data-end=\"2841\"\u003e• \u003cstrong data-start=\"2843\" data-end=\"2872\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"2872\" data-end=\"2875\"\u003e• \u003cstrong data-start=\"2877\" data-end=\"2931\"\u003eCooling capacity at 35 °C: 12,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2931\" data-end=\"2934\"\u003e• \u003cstrong data-start=\"2936\" data-end=\"2985\"\u003eHeating capacity at 8.3 °C: 12,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2985\" data-end=\"2988\"\u003e• \u003cstrong data-start=\"2990\" data-end=\"3011\"\u003eRefrigerant: R32\u003c\/strong\u003e\u003cbr data-start=\"3011\" data-end=\"3014\"\u003e• \u003cstrong data-start=\"3016\" data-end=\"3030\"\u003eSEER2: 20\u003c\/strong\u003e\u003cbr data-start=\"3030\" data-end=\"3033\"\u003e• \u003cstrong data-start=\"3035\" data-end=\"3051\"\u003eHSPF2 IV: 8\u003c\/strong\u003e\u003cbr data-start=\"3051\" data-end=\"3054\"\u003e• \u003cstrong data-start=\"3056\" data-end=\"3071\"\u003eEER2: 10.4\u003c\/strong\u003e\u003cbr data-start=\"3071\" data-end=\"3074\"\u003e• \u003cstrong data-start=\"3076\" data-end=\"3112\"\u003eHeating COP at 8.3 °C: 3.4 W\/W\u003c\/strong\u003e\u003cbr data-start=\"3112\" data-end=\"3115\"\u003e• \u003cstrong data-start=\"3117\" data-end=\"3143\"\u003eCOP at -15 °C: 1.9 W\/W\u003c\/strong\u003e\u003cbr data-start=\"3143\" data-end=\"3146\"\u003e• \u003cstrong data-start=\"3148\" data-end=\"3206\"\u003eNominal heating capacity at -8.3 °C: 7,200 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3206\" data-end=\"3209\"\u003e• \u003cstrong data-start=\"3211\" data-end=\"3268\"\u003eMaximum heating capacity at -15 °C: 6,100 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3268\" data-end=\"3271\"\u003e• \u003cstrong data-start=\"3273\" data-end=\"3330\"\u003eMaximum heating capacity at -20 °C: 5,800 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3330\" data-end=\"3333\"\u003e• \u003cstrong data-start=\"3335\" data-end=\"3361\"\u003eEnergy Star V6.1: no\u003c\/strong\u003e\u003cbr data-start=\"3361\" data-end=\"3364\"\u003e• \u003cstrong data-start=\"3366\" data-end=\"3407\"\u003eIndoor airflow: 253 to 400 CFM\u003c\/strong\u003e\u003cbr data-start=\"3407\" data-end=\"3410\"\u003e• \u003cstrong data-start=\"3412\" data-end=\"3475\"\u003eIndoor sound pressure: 46 \/ 40 \/ 32.5 \/ 30 \/ 28 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"3475\" data-end=\"3478\"\u003e• \u003cstrong data-start=\"3480\" data-end=\"3521\"\u003eOutdoor sound pressure: 52 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"3521\" data-end=\"3524\"\u003e• \u003cstrong data-start=\"3526\" data-end=\"3561\"\u003eVoltage: 115 V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"3561\" data-end=\"3564\"\u003e• \u003cstrong data-start=\"3566\" data-end=\"3613\"\u003eNominal cooling current: 10.5 A\u003c\/strong\u003e\u003cbr data-start=\"3613\" data-end=\"3616\"\u003e• \u003cstrong data-start=\"3618\" data-end=\"3658\"\u003eNominal heating current: 9.4 A\u003c\/strong\u003e\u003cbr data-start=\"3658\" data-end=\"3661\"\u003e• \u003cstrong data-start=\"3663\" data-end=\"3679\"\u003eMCA: 15.6 A\u003c\/strong\u003e\u003cbr data-start=\"3679\" data-end=\"3682\"\u003e• \u003cstrong data-start=\"3684\" data-end=\"3698\"\u003eMOP: 20 A\u003c\/strong\u003e\u003cbr data-start=\"3698\" data-end=\"3701\"\u003e• \u003cstrong data-start=\"3703\" data-end=\"3767\"\u003eCommunication wire required: 4\/14 copper multistrand 600 V\u003c\/strong\u003e\u003cbr data-start=\"3767\" data-end=\"3770\"\u003e• \u003cstrong data-start=\"3772\" data-end=\"3802\"\u003eCompressor: GMCC rotary\u003c\/strong\u003e\u003cbr data-start=\"3802\" data-end=\"3805\"\u003e• \u003cstrong data-start=\"3807\" data-end=\"3850\"\u003eExpansion device: capillary tube\u003c\/strong\u003e\u003cbr data-start=\"3850\" data-end=\"3853\"\u003e• \u003cstrong data-start=\"3855\" data-end=\"3884\"\u003eIndoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"3884\" data-end=\"3887\"\u003e• \u003cstrong data-start=\"3889\" data-end=\"3918\"\u003eOutdoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"3918\" data-end=\"3921\"\u003e• \u003cstrong data-start=\"3923\" data-end=\"3954\"\u003eLiquid piping: 1\/4 in\u003c\/strong\u003e\u003cbr data-start=\"3954\" data-end=\"3957\"\u003e• \u003cstrong data-start=\"3959\" data-end=\"3986\"\u003eGas piping: 3\/8 in\u003c\/strong\u003e\u003cbr data-start=\"3986\" data-end=\"3989\"\u003e• \u003cstrong data-start=\"3991\" data-end=\"4038\"\u003ePiping length min-max: 10 to 65 ft\u003c\/strong\u003e\u003cbr data-start=\"4038\" data-end=\"4041\"\u003e• \u003cstrong data-start=\"4043\" data-end=\"4077\"\u003eMaximum elevation difference: 50 ft\u003c\/strong\u003e\u003cbr data-start=\"4077\" data-end=\"4080\"\u003e• \u003cstrong data-start=\"4082\" data-end=\"4115\"\u003ePrecharge length: 25 ft\u003c\/strong\u003e\u003cbr data-start=\"4115\" data-end=\"4118\"\u003e• \u003cstrong data-start=\"4120\" data-end=\"4187\"\u003eIndoor unit dimensions L x D x H: 33.44 x 8.06 x 11.56 in\u003c\/strong\u003e\u003cbr data-start=\"4187\" data-end=\"4190\"\u003e• \u003cstrong data-start=\"4192\" data-end=\"4259\"\u003eOutdoor unit dimensions L x D x H: 28.13 x 9.50 x 21.25 in\u003c\/strong\u003e\u003cbr data-start=\"4259\" data-end=\"4262\"\u003e• \u003cstrong data-start=\"4264\" data-end=\"4309\"\u003eCooling range: -15 °C to 48 °C\u003c\/strong\u003e\u003cbr data-start=\"4309\" data-end=\"4312\"\u003e• \u003cstrong data-start=\"4314\" data-end=\"4353\"\u003eHeating range: -25 °C to 24 °C\u003c\/strong\u003e\u003cbr data-start=\"4353\" data-end=\"4356\" data-is-only-node=\"\"\u003e• \u003cstrong data-start=\"4358\" data-end=\"4401\"\u003eZephyr basic warranty: 10 years parts\u003c\/strong\u003e\u003cbr data-start=\"4401\" data-end=\"4404\"\u003e• \u003cstrong data-start=\"4406\" data-end=\"4473\"\u003eLabor warranty: available depending on the distributor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4475\" data-end=\"4929\"\u003eThis information is important because it directly affects the feasibility of the project. A \u003cstrong data-start=\"4581\" data-end=\"4604\"\u003e12,000 BTU heat pump at 115 V\u003c\/strong\u003e may be easier to integrate into some homes than a more powerful model at 208\/230 V, but that doesn’t mean the installation should be taken lightly. The \u003cstrong data-start=\"4780\" data-end=\"4797\"\u003eMCA of 15.6 A\u003c\/strong\u003e, the \u003cstrong data-start=\"4802\" data-end=\"4817\"\u003eMOP of 20 A\u003c\/strong\u003e, the type of wiring, piping, and drainage routing must be checked before confirming the work.\u003c\/p\u003e\n\u003ch2 data-start=\"4931\" data-end=\"4986\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4934\" data-end=\"4986\"\u003eA capacity of 12,000 BTU: for which spaces?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4988\" data-end=\"5321\"\u003eThe \u003cstrong data-start=\"4991\" data-end=\"5004\"\u003eZE-12DB22\u003c\/strong\u003e is a wall-mounted heat pump with \u003cstrong data-start=\"5035\" data-end=\"5049\"\u003e12,000 BTU\u003c\/strong\u003e, making it a common choice for medium-sized spaces. It can suit a closed main room, a living room, a larger bedroom, an office, a small open area, a condo, or a specific zone that needs better temperature control.\u003c\/p\u003e\n\u003cp data-start=\"5323\" data-end=\"5783\"\u003eAt AirGreen, we always avoid recommending capacity based solely on area. Two rooms of the same size can have completely different needs. A south-facing room with large windows may require more cooling than a shaded room. A poorly insulated space will require more heating than a recent, airtight room. A basement can be cool in summer but harder to heat depending on the layout.\u003c\/p\u003e\n\u003cp data-start=\"5785\" data-end=\"5827\"\u003eFor this model, we particularly analyze:\u003c\/p\u003e\n\u003cp data-start=\"5829\" data-end=\"6249\"\u003e• \u003cstrong data-start=\"5831\" data-end=\"5865\"\u003eactual area to be treated\u003c\/strong\u003e;\u003cbr data-start=\"5866\" data-end=\"5869\"\u003e• \u003cstrong data-start=\"5871\" data-end=\"5909\"\u003einsulation of walls and ceiling\u003c\/strong\u003e;\u003cbr data-start=\"5910\" data-end=\"5913\"\u003e• \u003cstrong data-start=\"5915\" data-end=\"5942\"\u003enumber of windows\u003c\/strong\u003e;\u003cbr data-start=\"5943\" data-end=\"5946\"\u003e• \u003cstrong data-start=\"5948\" data-end=\"5974\"\u003esun exposure\u003c\/strong\u003e;\u003cbr data-start=\"5975\" data-end=\"5978\"\u003e• \u003cstrong data-start=\"5980\" data-end=\"6007\"\u003eceiling height\u003c\/strong\u003e;\u003cbr data-start=\"6008\" data-end=\"6011\"\u003e• \u003cstrong data-start=\"6013\" data-end=\"6054\"\u003eair circulation between rooms\u003c\/strong\u003e;\u003cbr data-start=\"6055\" data-end=\"6058\"\u003e• \u003cstrong data-start=\"6060\" data-end=\"6108\"\u003epossible location of the indoor unit\u003c\/strong\u003e;\u003cbr data-start=\"6109\" data-end=\"6112\"\u003e• \u003cstrong data-start=\"6114\" data-end=\"6153\"\u003elocation of the outdoor unit\u003c\/strong\u003e;\u003cbr data-start=\"6154\" data-end=\"6157\"\u003e• \u003cstrong data-start=\"6159\" data-end=\"6201\"\u003edesired comfort level in winter\u003c\/strong\u003e;\u003cbr data-start=\"6202\" data-end=\"6205\"\u003e• \u003cstrong data-start=\"6207\" data-end=\"6248\"\u003eexisting electrical compatibility\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"6251\" data-end=\"6694\"\u003eA common mistake is to choose a larger heat pump \"just in case.\" However, an overly powerful unit can run in too-short cycles, dehumidify less effectively, and create a less natural comfort sensation. Conversely, a unit that is too small may run continuously and struggle during extreme days. \u003cstrong data-start=\"6606\" data-end=\"6694\"\u003eProper sizing is therefore essential to achieve stable and lasting comfort.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"6696\" data-end=\"6764\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6699\" data-end=\"6764\"\u003eR32 refrigerant: a modern technology that must be properly installed\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"6766\" data-end=\"7034\"\u003eThe \u003cstrong data-start=\"6769\" data-end=\"6782\"\u003eZE-12DB22\u003c\/strong\u003e operates with \u003cstrong data-start=\"6797\" data-end=\"6816\"\u003eR32 refrigerant\u003c\/strong\u003e. This refrigerant is used in several new generations of wall-mounted heat pumps. For the customer, the name of the refrigerant may seem secondary, but for HVAC installation, it is an important element.\u003c\/p\u003e\n\u003cp data-start=\"7036\" data-end=\"7461\"\u003eAn R32 unit must be installed with clean and rigorous methods. Piping lengths must be respected, connections well made, a serious vacuum drawn, system tightness checked, and refrigerant charge ensured to match project conditions. The datasheet indicates a charge of \u003cstrong data-start=\"7377\" data-end=\"7389\"\u003e22.22 oz\u003c\/strong\u003e for this model, with a precharge designed for \u003cstrong data-start=\"7437\" data-end=\"7446\"\u003e25 ft\u003c\/strong\u003e of piping.\u003c\/p\u003e\n\u003cp data-start=\"7463\" data-end=\"7810\"\u003eIn practice, this means that a project with a longer line must be properly evaluated. The brochure indicates a possible total piping length of \u003cstrong data-start=\"7632\" data-end=\"7646\"\u003e10 to 65 ft\u003c\/strong\u003e, with a maximum elevation difference of \u003cstrong data-start=\"7683\" data-end=\"7692\"\u003e50 ft\u003c\/strong\u003e. These limits must be respected to protect the unit’s performance and avoid long-term problems.\u003c\/p\u003e\n\u003cp data-start=\"7812\" data-end=\"8143\"\u003eAt AirGreen, we place great importance on these details. A modern heat pump properly installed can provide excellent comfort for many years. A rough installation, even with a good unit, can cause noise, performance loss, leaks, poor drainage, or premature wear.\u003c\/p\u003e\n\u003ch2 data-start=\"8145\" data-end=\"8222\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"8148\" data-end=\"8222\"\u003eHeating down to -25 °C: a useful solution for the Quebec climate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"8224\" data-end=\"8582\"\u003eThe Zephyr CB22 brochure states that this series offers heating down to \u003cstrong data-start=\"8299\" data-end=\"8309\"\u003e-25 °C\u003c\/strong\u003e and cooling down to \u003cstrong data-start=\"8340\" data-end=\"8350\"\u003e-15 °C\u003c\/strong\u003e outdoor temperature. For Quebec, this heating capacity is very interesting, especially for customers who want to reduce their conventional electric heating consumption for much of the winter.\u003c\/p\u003e\n\u003cp data-start=\"8584\" data-end=\"8659\"\u003eFor the \u003cstrong data-start=\"8592\" data-end=\"8605\"\u003eZE-12DB22\u003c\/strong\u003e, the low-temperature figures are as follows:\u003c\/p\u003e\n\u003cp data-start=\"8661\" data-end=\"8778\"\u003e• \u003cstrong data-start=\"8663\" data-end=\"8688\"\u003e7,200 BTU\/h at -8.3 °C\u003c\/strong\u003e;\u003cbr data-start=\"8689\" data-end=\"8692\"\u003e• \u003cstrong data-start=\"8694\" data-end=\"8718\"\u003e6,100 BTU\/h at -15 °C\u003c\/strong\u003e;\u003cbr data-start=\"8719\" data-end=\"8722\"\u003e• \u003cstrong data-start=\"8724\" data-end=\"8748\"\u003e5,800 BTU\/h at -20 °C\u003c\/strong\u003e;\u003cbr data-start=\"8749\" data-end=\"8752\"\u003e• \u003cstrong data-start=\"8754\" data-end=\"8777\"\u003eCOP of 1.9 at -15 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"8780\" data-end=\"9286\"\u003eThese values show that the unit continues to heat as the temperature drops, but they also reveal an important reality: \u003cstrong data-start=\"8919\" data-end=\"8969\"\u003eheating capacity decreases with the cold\u003c\/strong\u003e. This is normal for a heat pump. In a well-insulated room, this capacity can be sufficient to maintain good comfort for much of the winter. In an older house, poorly insulated or very exposed to wind, supplementary heating may still be necessary on the coldest days.\u003c\/p\u003e\n\u003cp data-start=\"9288\" data-end=\"9543\"\u003eAt AirGreen, we prefer to explain this reality clearly. A wall-mounted heat pump is not just an air conditioning device. It is also a very useful heating tool, but it must be intelligently integrated into the existing building.\u003c\/p\u003e\n\u003ch2 data-start=\"9545\" data-end=\"9628\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"9548\" data-end=\"9628\"\u003eIndoor comfort: Inverter technology, 4D mode, and automatic oscillation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"9630\" data-end=\"9895\"\u003eThe Zephyr CB22 series focuses on \u003cstrong data-start=\"9671\" data-end=\"9690\"\u003eoptimal comfort\u003c\/strong\u003e. The brochure states that variable frequency technology allows the heat pump to adjust its power in real time, which helps reduce temperature fluctuations and energy consumption.\u003c\/p\u003e\n\u003cp data-start=\"9897\" data-end=\"10294\"\u003eThe \u003cstrong data-start=\"9900\" data-end=\"9913\"\u003eZE-12DB22\u003c\/strong\u003e also benefits from a \u003cstrong data-start=\"9935\" data-end=\"9946\"\u003e4D mode\u003c\/strong\u003e and \u003cstrong data-start=\"9956\" data-end=\"9983\"\u003eautomatic oscillation\u003c\/strong\u003e. This feature helps better distribute air in the room to achieve a more balanced temperature. For a wall unit, air distribution is a very important element. Poor positioning can create a zone that is too cold near the unit and a zone that is too warm further away in the room.\u003c\/p\u003e\n\u003cp data-start=\"10296\" data-end=\"10568\"\u003eWith an airflow rate of \u003cstrong data-start=\"10319\" data-end=\"10336\"\u003e253 to 400 CFM\u003c\/strong\u003e, this model can ensure good circulation in a suitably sized room. The \u003cstrong data-start=\"10424\" data-end=\"10464\"\u003e5 indoor fan speeds\u003c\/strong\u003e allow adjusting comfort according to the season, time of day, and occupant sensitivity.\u003c\/p\u003e\n\u003cp data-start=\"10570\" data-end=\"10633\"\u003eThe brochure also mentions several practical features:\u003c\/p\u003e\n\u003cp data-start=\"10635\" data-end=\"11194\"\u003e• \u003cstrong data-start=\"10637\" data-end=\"10650\"\u003eNight Mode\u003c\/strong\u003e;\u003cbr data-start=\"10651\" data-end=\"10654\"\u003e• \u003cstrong data-start=\"10656\" data-end=\"10672\"\u003eSilent Mode\u003c\/strong\u003e;\u003cbr data-start=\"10673\" data-end=\"10676\"\u003e• \u003cstrong data-start=\"10678\" data-end=\"10692\"\u003eiFeel Mode\u003c\/strong\u003e;\u003cbr data-start=\"10693\" data-end=\"10696\"\u003e• \u003cstrong data-start=\"10698\" data-end=\"10718\"\u003eQuick Start\u003c\/strong\u003e;\u003cbr data-start=\"10719\" data-end=\"10722\"\u003e• \u003cstrong data-start=\"10724\" data-end=\"10741\"\u003e24h Timer\u003c\/strong\u003e;\u003cbr data-start=\"10742\" data-end=\"10745\"\u003e• \u003cstrong data-start=\"10747\" data-end=\"10765\"\u003eTurbo Function\u003c\/strong\u003e;\u003cbr data-start=\"10766\" data-end=\"10769\"\u003e• \u003cstrong data-start=\"10771\" data-end=\"10796\"\u003eAutomatic Defrost\u003c\/strong\u003e;\u003cbr data-start=\"10797\" data-end=\"10800\"\u003e• \u003cstrong data-start=\"10802\" data-end=\"10827\"\u003eAutomatic Cleaning\u003c\/strong\u003e;\u003cbr data-start=\"10828\" data-end=\"10831\"\u003e• \u003cstrong data-start=\"10833\" data-end=\"10862\"\u003eLED Wireless Remote Control\u003c\/strong\u003e;\u003cbr data-start=\"10863\" data-end=\"10866\"\u003e• \u003cstrong data-start=\"10868\" data-end=\"10887\"\u003eLED Dimmer\u003c\/strong\u003e;\u003cbr data-start=\"10888\" data-end=\"10891\"\u003e• \u003cstrong data-start=\"10893\" data-end=\"10929\"\u003eDiffuser position memory\u003c\/strong\u003e;\u003cbr data-start=\"10930\" data-end=\"10933\"\u003e• \u003cstrong data-start=\"10935\" data-end=\"10973\"\u003eAutomatic 8 °C \/ 46 °F heating\u003c\/strong\u003e;\u003cbr data-start=\"10974\" data-end=\"10977\"\u003e• \u003cstrong data-start=\"10979\" data-end=\"11007\"\u003eReversible drain pipe\u003c\/strong\u003e;\u003cbr data-start=\"11008\" data-end=\"11011\"\u003e• \u003cstrong data-start=\"11013\" data-end=\"11035\"\u003eTwo-sided drain\u003c\/strong\u003e;\u003cbr data-start=\"11036\" data-end=\"11039\"\u003e• \u003cstrong data-start=\"11041\" data-end=\"11076\"\u003eOutdoor base heating\u003c\/strong\u003e;\u003cbr data-start=\"11077\" data-end=\"11080\"\u003e• \u003cstrong data-start=\"11082\" data-end=\"11110\"\u003eCompressor heating\u003c\/strong\u003e;\u003cbr data-start=\"11111\" data-end=\"11114\"\u003e• \u003cstrong data-start=\"11116\" data-end=\"11145\"\u003eFireproof electrical box\u003c\/strong\u003e;\u003cbr data-start=\"11146\" data-end=\"11149\"\u003e• \u003cstrong data-start=\"11151\" data-end=\"11193\"\u003eAuto-adaptive voltage technology\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"11196\" data-end=\"11619\"\u003eThese features improve daily use. The \u003cstrong data-start=\"11251\" data-end=\"11267\"\u003esilent mode\u003c\/strong\u003e can be useful in a bedroom or office. The \u003cstrong data-start=\"11324\" data-end=\"11337\"\u003enight mode\u003c\/strong\u003e helps maintain a gentler comfort during sleep. The \u003cstrong data-start=\"11399\" data-end=\"11413\"\u003eiFeel mode\u003c\/strong\u003e can improve temperature reading around the user based on the remote control's position. The \u003cstrong data-start=\"11520\" data-end=\"11545\"\u003eautomatic defrost\u003c\/strong\u003e and \u003cstrong data-start=\"11552\" data-end=\"11580\"\u003ecompressor heating\u003c\/strong\u003e are particularly useful in winter.\u003c\/p\u003e\n\u003ch2 data-start=\"11621\" data-end=\"11686\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11624\" data-end=\"11686\"\u003eSound level: a point to consider before installation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"11688\" data-end=\"11985\"\u003eThe technical sheet indicates an indoor sound pressure level of \u003cstrong data-start=\"11749\" data-end=\"11783\"\u003e46 \/ 40 \/ 32.5 \/ 30 \/ 28 dB(A)\u003c\/strong\u003e depending on the selected speed, including silent mode. At low speed, the device can therefore operate discreetly, which is important in a bedroom, office, or relaxation area.\u003c\/p\u003e\n\u003cp data-start=\"11987\" data-end=\"12360\"\u003eThe outdoor unit has a sound pressure level of \u003cstrong data-start=\"12037\" data-end=\"12049\"\u003e52 dB(A)\u003c\/strong\u003e. This level is relatively reasonable, but the location remains very important. In dense areas of Montreal, Longueuil, or certain neighborhoods of Laval, it is necessary to avoid placing the outdoor unit too close to a bedroom window, a neighboring balcony, or a narrow passage that can amplify the sound.\u003c\/p\u003e\n\u003cp data-start=\"12362\" data-end=\"12648\"\u003eAt AirGreen, we always assess the location of the outdoor unit based on several criteria: clearances, maintenance access, noise, snow, ice, drainage, and aesthetics. \u003cstrong data-start=\"12545\" data-end=\"12648\"\u003eA good outdoor location directly contributes to the customer's performance and peace of mind.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"12650\" data-end=\"12706\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"12653\" data-end=\"12706\"\u003eInstallation: the details that make the difference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"12708\" data-end=\"12886\"\u003eA good wall-mounted heat pump installation is not limited to mounting a unit on the wall. For the \u003cstrong data-start=\"12804\" data-end=\"12817\"\u003eZE-12DB22\u003c\/strong\u003e, several elements must be validated before starting work.\u003c\/p\u003e\n\u003ch2 data-start=\"12888\" data-end=\"12928\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"12891\" data-end=\"12928\"\u003eIndoor unit location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"12930\" data-end=\"13260\"\u003eThe indoor unit measures approximately \u003cstrong data-start=\"12964\" data-end=\"12991\"\u003e33.44 x 8.06 x 11.56 in\u003c\/strong\u003e in L x D x H format. It is a relatively compact size, which facilitates installation in various types of rooms. However, a wall should be chosen that allows good air diffusion without blowing directly on occupants for long periods.\u003c\/p\u003e\n\u003cp data-start=\"13262\" data-end=\"13603\"\u003eIn a living room, the unit should ideally push air toward the main area without being blocked by a tall piece of furniture, a beam, or a partition. In a bedroom, avoid directing the airflow directly onto the bed. In an office, consider the position of the workstation to avoid a draft sensation.\u003c\/p\u003e\n\u003ch2 data-start=\"13605\" data-end=\"13645\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"13608\" data-end=\"13645\"\u003eOutdoor unit location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"13647\" data-end=\"13959\"\u003eThe outdoor unit measures approximately \u003cstrong data-start=\"13681\" data-end=\"13708\"\u003e28.13 x 9.50 x 21.25 in\u003c\/strong\u003e in L x D x H format. It is more compact than larger capacity units, which can be advantageous in limited spaces. Despite this, the necessary clearances must be respected to allow the unit to breathe properly.\u003c\/p\u003e\n\u003cp data-start=\"13961\" data-end=\"14317\"\u003eOn the South Shore and North Shore, we often see installations where snow and ice have not been sufficiently taken into account. In Montreal and Longueuil, space constraints are sometimes more significant. The outdoor unit must be installed on a stable base, at an appropriate height, and in a location accessible for future maintenance.\u003c\/p\u003e\n\u003ch2 data-start=\"14319\" data-end=\"14349\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"14322\" data-end=\"14349\"\u003ePiping 1\/4 - 3\/8 in\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"14351\" data-end=\"14655\"\u003eThe \u003cstrong data-start=\"14354\" data-end=\"14367\"\u003eZE-12DB22\u003c\/strong\u003e uses a liquid line of \u003cstrong data-start=\"14402\" data-end=\"14412\"\u003e1\/4 in\u003c\/strong\u003e and a gas line of \u003cstrong data-start=\"14438\" data-end=\"14448\"\u003e3\/8 in\u003c\/strong\u003e. This configuration is common for several small and medium capacity wall-mounted heat pumps. When replacing, it is essential to check if the existing lines are compatible.\u003c\/p\u003e\n\u003cp data-start=\"14657\" data-end=\"15067\"\u003eNever assume that the old piping can be reused without inspection. We check the diameter, the condition of the lines, the presence of old oil, the old type of refrigerant, the length of the run, and accessibility. In some cases, reusing an existing line may be possible. In others, replacing the piping is the best solution to protect the new system.\u003c\/p\u003e\n\u003ch2 data-start=\"15069\" data-end=\"15105\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"15072\" data-end=\"15105\"\u003ePower supply 115 V\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"15107\" data-end=\"15461\"\u003eA practical advantage of the \u003cstrong data-start=\"15138\" data-end=\"15151\"\u003eZE-12DB22\u003c\/strong\u003e model is its \u003cstrong data-start=\"15176\" data-end=\"15185\"\u003e115 V\u003c\/strong\u003e power supply. This can facilitate certain projects, especially when a customer wants to avoid the constraints of a more powerful 208\/230 V device. However, the sheet indicates an \u003cstrong data-start=\"15351\" data-end=\"15368\"\u003eMCA of 15.6 A\u003c\/strong\u003e and an \u003cstrong data-start=\"15375\" data-end=\"15390\"\u003eMOP of 20 A\u003c\/strong\u003e, meaning an appropriate circuit must still be planned.\u003c\/p\u003e\n\u003cp data-start=\"15463\" data-end=\"15735\"\u003eWe always check the electrical panel, wire gauge, required protection, and connection compliance. This step is especially important in older homes in Montreal, Laval, or Longueuil, where panels may already be loaded.\u003c\/p\u003e\n\u003ch2 data-start=\"15737\" data-end=\"15800\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"15740\" data-end=\"15800\"\u003eEnergy Performance: reading the numbers correctly\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"15802\" data-end=\"16071\"\u003eThe \u003cstrong data-start=\"15805\" data-end=\"15818\"\u003eZE-12DB22\u003c\/strong\u003e shows a \u003cstrong data-start=\"15830\" data-end=\"15845\"\u003eSEER2 of 20\u003c\/strong\u003e, an \u003cstrong data-start=\"15850\" data-end=\"15864\"\u003eHSPF2 of 8\u003c\/strong\u003e, an \u003cstrong data-start=\"15869\" data-end=\"15885\"\u003eEER2 of 10.4\u003c\/strong\u003e, and a \u003cstrong data-start=\"15892\" data-end=\"15915\"\u003eCOP of 3.4 at 8.3 °C\u003c\/strong\u003e. These data help better understand the device’s efficiency, but they must always be interpreted in the real installation context.\u003c\/p\u003e\n\u003cp data-start=\"16073\" data-end=\"16382\"\u003eThe \u003cstrong data-start=\"16076\" data-end=\"16085\"\u003eSEER2\u003c\/strong\u003e indicates seasonal cooling efficiency. The \u003cstrong data-start=\"16140\" data-end=\"16149\"\u003eHSPF2\u003c\/strong\u003e provides an indication of seasonal heating efficiency. The \u003cstrong data-start=\"16217\" data-end=\"16225\"\u003eEER2\u003c\/strong\u003e represents cooling efficiency under specific conditions. The \u003cstrong data-start=\"16302\" data-end=\"16309\"\u003eCOP\u003c\/strong\u003e indicates the ratio between heat produced and electricity consumed.\u003c\/p\u003e\n\u003cp data-start=\"16384\" data-end=\"16844\"\u003eThe sheet also indicates that this model is \u003cstrong data-start=\"16425\" data-end=\"16451\"\u003eEnergy Star V6.1: no\u003c\/strong\u003e. This is an important detail not to overlook. For customers looking for a heat pump mainly based on energy efficiency programs, eligibility must be checked separately before making a decision. At AirGreen, we help our clients compare options based on comfort, budget, performance, and applicable requirements at the time of the project.\u003c\/p\u003e\n\u003ch2 data-start=\"16846\" data-end=\"16912\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"16849\" data-end=\"16912\"\u003eHVAC Maintenance: preserving performance year after year\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"16914\" data-end=\"17100\"\u003eA well-installed wall-mounted heat pump must also be well maintained. Even if the brochure mentions an \u003cstrong data-start=\"17031\" data-end=\"17056\"\u003eautomatic cleaning\u003c\/strong\u003e function, this does not replace regular maintenance.\u003c\/p\u003e\n\u003cp data-start=\"17102\" data-end=\"17131\"\u003eWe especially recommend:\u003c\/p\u003e\n\u003cp data-start=\"17133\" data-end=\"17592\"\u003e• \u003cstrong data-start=\"17135\" data-end=\"17173\"\u003ecleaning the filters regularly\u003c\/strong\u003e;\u003cbr data-start=\"17174\" data-end=\"17177\"\u003e• ensuring the condensate drain remains clear;\u003cbr data-start=\"17230\" data-end=\"17233\"\u003e• keeping the outdoor unit free of leaves, dust, snow, and ice;\u003cbr data-start=\"17306\" data-end=\"17309\"\u003e• monitoring for any unusual noises;\u003cbr data-start=\"17344\" data-end=\"17347\"\u003e• having the unit inspected if performance decreases;\u003cbr data-start=\"17402\" data-end=\"17405\"\u003e• cleaning the indoor heat exchanger when necessary;\u003cbr data-start=\"17457\" data-end=\"17460\"\u003e• checking clearances around the outdoor unit before winter;\u003cbr data-start=\"17530\" data-end=\"17533\"\u003e• scheduling professional maintenance based on usage.\u003c\/p\u003e\n\u003cp data-start=\"17594\" data-end=\"17842\"\u003eA clean unit works better, consumes less, makes less noise, and offers better air quality. For a model like the \u003cstrong data-start=\"17729\" data-end=\"17742\"\u003eZE-12DB22\u003c\/strong\u003e, simple but regular maintenance can make a big difference in the system’s lifespan.\u003c\/p\u003e\n\u003ch2 data-start=\"17844\" data-end=\"17896\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"17847\" data-end=\"17896\"\u003eMistakes to avoid before buying the ZE-12DB22\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"17898\" data-end=\"18092\"\u003eIn our experience, the most costly mistakes often come from poor evaluation before installation. Before choosing a \u003cstrong data-start=\"18057\" data-end=\"18071\"\u003e12,000 BTU\u003c\/strong\u003e wall-mounted heat pump, avoid:\u003c\/p\u003e\n\u003cp data-start=\"18094\" data-end=\"18671\"\u003e• choosing capacity based solely on price;\u003cbr data-start=\"18141\" data-end=\"18144\"\u003e• installing the indoor unit without considering air distribution;\u003cbr data-start=\"18208\" data-end=\"18211\"\u003e• forgetting to check the electrical panel;\u003cbr data-start=\"18255\" data-end=\"18258\"\u003e• assuming old refrigerant lines are compatible;\u003cbr data-start=\"18325\" data-end=\"18328\"\u003e• neglecting drainage;\u003cbr data-start=\"18351\" data-end=\"18354\"\u003e• placing the outdoor unit too close to a wall or neighbor;\u003cbr data-start=\"18416\" data-end=\"18419\"\u003e• ignoring snow accumulation;\u003cbr data-start=\"18456\" data-end=\"18459\"\u003e• comparing only the SEER2 without considering heating performance;\u003cbr data-start=\"18531\" data-end=\"18534\"\u003e• forgetting that the model \u003cstrong data-start=\"18558\" data-end=\"18598\"\u003eZE-12DB22 is not Energy Star V6.1\u003c\/strong\u003e;\u003cbr data-start=\"18599\" data-end=\"18602\"\u003e• buying without verifying if the unit truly fits the room.\u003c\/p\u003e\n\u003cp data-start=\"18673\" data-end=\"18865\"\u003eAt AirGreen, our role is to clarify these points before the work begins. This helps avoid unpleasant surprises, unrealistic expectations, and costly adjustments after installation.\u003c\/p\u003e\n\u003ch2 data-start=\"18867\" data-end=\"18939\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"18870\" data-end=\"18939\"\u003eWhy choose AirGreen to install the Zephyr CB22 ZE-12DB22\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"18941\" data-end=\"19232\"\u003eAirGreen is a company specializing in \u003cstrong data-start=\"18984\" data-end=\"18992\"\u003eHVAC\u003c\/strong\u003e that installs, maintains, and repairs wall-mounted, central, and multi-zone heat pumps in the greater Montreal area. Our team regularly serves \u003cstrong data-start=\"19153\" data-end=\"19231\"\u003eMontreal, Laval, Longueuil, the South Shore, the North Shore, and Montérégie\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"19234\" data-end=\"19340\"\u003eBy choosing AirGreen for the installation of the \u003cstrong data-start=\"19284\" data-end=\"19313\"\u003eZephyr CB22 R32 ZE-12DB22\u003c\/strong\u003e, customers benefit from:\u003c\/p\u003e\n\u003cp data-start=\"19342\" data-end=\"19811\"\u003e• \u003cstrong data-start=\"19344\" data-end=\"19389\"\u003ea clear evaluation before work begins\u003c\/strong\u003e;\u003cbr data-start=\"19390\" data-end=\"19393\"\u003e• a device choice adapted to the building;\u003cbr data-start=\"19436\" data-end=\"19439\"\u003e• installation compliant with good HVAC practices;\u003cbr data-start=\"19495\" data-end=\"19498\"\u003e• verification of piping and electrical circuit;\u003cbr data-start=\"19561\" data-end=\"19564\"\u003e• an honest explanation of heating performance;\u003cbr data-start=\"19622\" data-end=\"19625\"\u003e• a structured after-sales service;\u003cbr data-start=\"19662\" data-end=\"19665\"\u003e• a team familiar with the realities of Quebec buildings;\u003cbr data-start=\"19726\" data-end=\"19729\"\u003e• support to understand warranties, maintenance, and usage.\u003c\/p\u003e\n\u003cp data-start=\"19813\" data-end=\"20069\"\u003eWe know that a heat pump is a significant investment. Our goal is for the customer to understand what they are buying, why this model is recommended, how it will be installed, and how it should be used to deliver its best performance.\u003c\/p\u003e\n\u003ch2 data-start=\"20071\" data-end=\"20147\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"20074\" data-end=\"20147\"\u003eA simple, efficient HVAC solution well suited for medium-sized spaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"20149\" data-end=\"20577\"\u003eThe \u003cstrong data-start=\"20152\" data-end=\"20200\"\u003eZephyr CB22 R32 ZE-12DB22 Wall Heat Pump\u003c\/strong\u003e is an interesting solution for customers looking for a \u003cstrong data-start=\"20290\" data-end=\"20304\"\u003e12,000 BTU\u003c\/strong\u003e wall heat pump, powered by \u003cstrong data-start=\"20319\" data-end=\"20328\"\u003e115 V\u003c\/strong\u003e, operating with \u003cstrong data-start=\"20346\" data-end=\"20353\"\u003eR32\u003c\/strong\u003e, capable of heating down to \u003cstrong data-start=\"20383\" data-end=\"20393\"\u003e-25 °C\u003c\/strong\u003e, and equipped with useful features such as \u003cstrong data-start=\"20432\" data-end=\"20443\"\u003e4D mode\u003c\/strong\u003e, \u003cstrong data-start=\"20448\" data-end=\"20464\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"20469\" data-end=\"20482\"\u003enight mode\u003c\/strong\u003e, \u003cstrong data-start=\"20487\" data-end=\"20512\"\u003eautomatic defrost\u003c\/strong\u003e, \u003cstrong data-start=\"20517\" data-end=\"20545\"\u003ecompressor heating\u003c\/strong\u003e, and \u003cstrong data-start=\"20552\" data-end=\"20576\"\u003eInverter technology\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"20579\" data-end=\"20975\"\u003eIt is especially suitable for projects where the goal is to improve comfort in a specific area without installing an overly powerful unit. Its compact size, \u003cstrong data-start=\"20759\" data-end=\"20775\"\u003e1\/4 - 3\/8 inch\u003c\/strong\u003e piping, low indoor noise level in silent mode, and heating operating range make it a practical option for many homes, condos, and small commercial spaces in Greater Montreal.\u003c\/p\u003e\n\u003cp data-start=\"20977\" data-end=\"21299\"\u003eTo get a clear quote, compare this model with other Zephyr options or schedule an installation in \u003cstrong data-start=\"21093\" data-end=\"21156\"\u003eMontreal, Laval, Longueuil, on the South Shore or the North Shore\u003c\/strong\u003e, contact AirGreen. Our team will help you choose the right HVAC solution based on your building, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665925325092,"sku":"ZE-12DB22I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRCB22R32GRANDMONTREAL_5756f407-492d-449c-b2e2-8e38ffb4b10c.png?v=1783695957"},{"product_id":"thermopompe-murale-zephyr-cb22-r32-9000-btu-montreal-laval-rive-sud","title":"ZEPHYR CB22 R32 Wall Heat Pump | 9000 BTU | Montreal, Laval, South Shore","description":"\u003ch1 data-start=\"0\" data-end=\"133\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2\" data-end=\"133\"\u003eZephyr CB22 R32 ZE-09CB22 Wall-Mounted Heat Pump: a compact, efficient 9,000 BTU solution well suited for residential comfort\u003c\/strong\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"135\" data-end=\"705\"\u003eThe \u003cstrong data-start=\"138\" data-end=\"186\"\u003eZephyr CB22 R32 ZE-09CB22 Wall-Mounted Heat Pump\u003c\/strong\u003e is aimed at homeowners looking for a simple, reliable, and efficient HVAC solution to cool and heat a specific area of their home, condo, office, or small commercial space. With its \u003cstrong data-start=\"402\" data-end=\"415\"\u003e9,000 BTU\u003c\/strong\u003e capacity, operation with \u003cstrong data-start=\"439\" data-end=\"458\"\u003eR32 refrigerant\u003c\/strong\u003e, efficiency of \u003cstrong data-start=\"477\" data-end=\"491\"\u003e22.5 SEER2\u003c\/strong\u003e, and heating capacity down to \u003cstrong data-start=\"528\" data-end=\"538\"\u003e-25 °C\u003c\/strong\u003e, this model represents an interesting option for projects seeking a good balance between comfort, energy efficiency, and reasonable installation cost.\u003c\/p\u003e\n\u003cp data-start=\"707\" data-end=\"1225\"\u003eAt AirGreen, we recommend this type of wall-mounted heat pump when the need is well targeted: a master bedroom, a home office, a small living room, a room above a garage, a well-insulated condo, or an area that remains uncomfortable despite existing heating or cooling. The model \u003cstrong data-start=\"1017\" data-end=\"1030\"\u003eZE-09CB22\u003c\/strong\u003e is not designed to replace a large 18,000 or 24,000 BTU heat pump in a large open area, but it can deliver excellent results when installed in the right context.\u003c\/p\u003e\n\u003cp data-start=\"1227\" data-end=\"1812\"\u003eThe Zephyr CB22 brochure highlights a wall-mounted heat pump with \u003cstrong data-start=\"1290\" data-end=\"1297\"\u003eR32\u003c\/strong\u003e, featuring \u003cstrong data-start=\"1304\" data-end=\"1332\"\u003eheating down to -25 °C\u003c\/strong\u003e, \u003cstrong data-start=\"1334\" data-end=\"1366\"\u003ecooling down to -15 °C\u003c\/strong\u003e, variable frequency technology, silent mode, night mode, iFeel mode, quick start, 24-hour timer, automatic oscillation, 4D mode, and a basic warranty of \u003cstrong data-start=\"1529\" data-end=\"1546\"\u003e10 years on parts\u003c\/strong\u003e. For the model \u003cstrong data-start=\"1563\" data-end=\"1576\"\u003eZE-09CB22\u003c\/strong\u003e, the technical sheet notably indicates \u003cstrong data-start=\"1615\" data-end=\"1647\"\u003e9,000 BTU cooling capacity\u003c\/strong\u003e, \u003cstrong data-start=\"1649\" data-end=\"1663\"\u003e22.5 SEER2\u003c\/strong\u003e, \u003cstrong data-start=\"1665\" data-end=\"1676\"\u003e9 HSPF2\u003c\/strong\u003e, \u003cstrong data-start=\"1678\" data-end=\"1698\"\u003eEnergy Star V6.1\u003c\/strong\u003e, a power supply of \u003cstrong data-start=\"1717\" data-end=\"1730\"\u003e208\/230 V\u003c\/strong\u003e, a \u003cstrong data-start=\"1735\" data-end=\"1750\"\u003e15 A MOP\u003c\/strong\u003e, and a \u003cstrong data-start=\"1757\" data-end=\"1773\"\u003e9.5 A MCA\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch1 data-start=\"1814\" data-end=\"1875\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1816\" data-end=\"1875\"\u003eImportant technical features to know\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"1877\" data-end=\"1968\"\u003eFor the model \u003cstrong data-start=\"1892\" data-end=\"1917\"\u003eZephyr CB22 ZE-09CB22\u003c\/strong\u003e, the main information is as follows:\u003c\/p\u003e\n\u003cp data-start=\"1970\" data-end=\"3360\"\u003e• \u003cstrong data-start=\"1972\" data-end=\"1991\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"1991\" data-end=\"1994\"\u003e• \u003cstrong data-start=\"1996\" data-end=\"2012\"\u003eSeries: CB22\u003c\/strong\u003e\u003cbr data-start=\"2012\" data-end=\"2015\"\u003e• \u003cstrong data-start=\"2017\" data-end=\"2046\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"2046\" data-end=\"2049\"\u003e• \u003cstrong data-start=\"2051\" data-end=\"2073\"\u003eModel: ZE-09CB22\u003c\/strong\u003e\u003cbr data-start=\"2073\" data-end=\"2076\"\u003e• \u003cstrong data-start=\"2078\" data-end=\"2131\"\u003eCooling capacity at 35 °C: 9,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2131\" data-end=\"2134\"\u003e• \u003cstrong data-start=\"2136\" data-end=\"2184\"\u003eHeating capacity at 8.3 °C: 9,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2184\" data-end=\"2187\"\u003e• \u003cstrong data-start=\"2189\" data-end=\"2205\"\u003eSEER2: 22.5\u003c\/strong\u003e\u003cbr data-start=\"2205\" data-end=\"2208\"\u003e• \u003cstrong data-start=\"2210\" data-end=\"2226\"\u003eHSPF2 IV: 9\u003c\/strong\u003e\u003cbr data-start=\"2226\" data-end=\"2229\"\u003e• \u003cstrong data-start=\"2231\" data-end=\"2252\"\u003eEER2: 12.5 BTU\/W\u003c\/strong\u003e\u003cbr data-start=\"2252\" data-end=\"2255\"\u003e• \u003cstrong data-start=\"2257\" data-end=\"2289\"\u003eHeating COP at 8.3 °C: 3.9\u003c\/strong\u003e\u003cbr data-start=\"2289\" data-end=\"2292\"\u003e• \u003cstrong data-start=\"2294\" data-end=\"2325\"\u003eCOP2 heating: 13.4 BTU\/W\u003c\/strong\u003e\u003cbr data-start=\"2325\" data-end=\"2328\"\u003e• \u003cstrong data-start=\"2330\" data-end=\"2388\"\u003eNominal heating capacity at -8.3 °C: 6,500 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2388\" data-end=\"2391\"\u003e• \u003cstrong data-start=\"2393\" data-end=\"2450\"\u003eMaximum heating capacity at -15 °C: 5,400 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2450\" data-end=\"2453\"\u003e• \u003cstrong data-start=\"2455\" data-end=\"2477\"\u003eCOP at -15 °C: 2.1\u003c\/strong\u003e\u003cbr data-start=\"2477\" data-end=\"2480\"\u003e• \u003cstrong data-start=\"2482\" data-end=\"2539\"\u003eMaximum heating capacity at -20 °C: 4,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2539\" data-end=\"2542\"\u003e• \u003cstrong data-start=\"2544\" data-end=\"2570\"\u003eEnergy Star V6.1: yes\u003c\/strong\u003e\u003cbr data-start=\"2570\" data-end=\"2573\"\u003e• \u003cstrong data-start=\"2575\" data-end=\"2596\"\u003eRefrigerant: R32\u003c\/strong\u003e\u003cbr data-start=\"2596\" data-end=\"2599\"\u003e• \u003cstrong data-start=\"2601\" data-end=\"2637\"\u003eRefrigerant charge: 21.52 oz\u003c\/strong\u003e\u003cbr data-start=\"2637\" data-end=\"2640\"\u003e• \u003cstrong data-start=\"2642\" data-end=\"2673\"\u003eAirflow: 218 to 400 CFM\u003c\/strong\u003e\u003cbr data-start=\"2673\" data-end=\"2676\"\u003e• \u003cstrong data-start=\"2678\" data-end=\"2743\"\u003eIndoor sound pressure: 45 \/ 40 \/ 32 \/ 30 \/ 28 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"2743\" data-end=\"2746\"\u003e• \u003cstrong data-start=\"2748\" data-end=\"2793\"\u003eOutdoor sound pressure: 53 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"2793\" data-end=\"2796\"\u003e• \u003cstrong data-start=\"2798\" data-end=\"2837\"\u003eVoltage: 208\/230 V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"2837\" data-end=\"2840\"\u003e• \u003cstrong data-start=\"2842\" data-end=\"2888\"\u003eNominal cooling current: 3.4 A\u003c\/strong\u003e\u003cbr data-start=\"2888\" data-end=\"2891\"\u003e• \u003cstrong data-start=\"2893\" data-end=\"2933\"\u003eNominal heating current: 3.1 A\u003c\/strong\u003e\u003cbr data-start=\"2933\" data-end=\"2936\"\u003e• \u003cstrong data-start=\"2938\" data-end=\"2953\"\u003eMCA: 9.5 A\u003c\/strong\u003e\u003cbr data-start=\"2953\" data-end=\"2956\"\u003e• \u003cstrong data-start=\"2958\" data-end=\"2972\"\u003eMOP: 15 A\u003c\/strong\u003e\u003cbr data-start=\"2972\" data-end=\"2975\"\u003e• \u003cstrong data-start=\"2977\" data-end=\"3041\"\u003eRequired communication wire: 4\/14 copper multistrand 600 V\u003c\/strong\u003e\u003cbr data-start=\"3041\" data-end=\"3044\"\u003e• \u003cstrong data-start=\"3046\" data-end=\"3077\"\u003eLiquid piping: 1\/4 in\u003c\/strong\u003e\u003cbr data-start=\"3077\" data-end=\"3080\"\u003e• \u003cstrong data-start=\"3082\" data-end=\"3109\"\u003eGas piping: 3\/8 in\u003c\/strong\u003e\u003cbr data-start=\"3109\" data-end=\"3112\"\u003e• \u003cstrong data-start=\"3114\" data-end=\"3164\"\u003eMinimum-maximum piping length: 10 to 65 feet\u003c\/strong\u003e\u003cbr data-start=\"3164\" data-end=\"3167\"\u003e• \u003cstrong data-start=\"3169\" data-end=\"3206\"\u003eMaximum elevation difference: 50 feet\u003c\/strong\u003e\u003cbr data-start=\"3206\" data-end=\"3209\"\u003e• \u003cstrong data-start=\"3211\" data-end=\"3247\"\u003ePrecharge length: 25 feet\u003c\/strong\u003e\u003cbr data-start=\"3247\" data-end=\"3250\"\u003e• \u003cstrong data-start=\"3252\" data-end=\"3295\"\u003eZephyr basic warranty: 10 years parts\u003c\/strong\u003e\u003cbr data-start=\"3295\" data-end=\"3298\"\u003e• \u003cstrong data-start=\"3300\" data-end=\"3360\"\u003eLabor warranty: available according to the distributor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3362\" data-end=\"3552\"\u003eThe dimensions indicated in the technical sheet are in \u003cstrong data-start=\"3426\" data-end=\"3439\"\u003eL × H × D\u003c\/strong\u003e format. To facilitate reading during an installation project, we can present them in \u003cstrong data-start=\"3537\" data-end=\"3550\"\u003eL × D × H\u003c\/strong\u003e format:\u003c\/p\u003e\n\u003cp data-start=\"3554\" data-end=\"3653\"\u003e• \u003cstrong data-start=\"3556\" data-end=\"3602\"\u003eIndoor unit: 33.44 × 8.06 × 11.56 in\u003c\/strong\u003e\u003cbr data-start=\"3602\" data-end=\"3605\"\u003e• \u003cstrong data-start=\"3607\" data-end=\"3653\"\u003eOutdoor unit: 28.13 × 9.50 × 21.25 in\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3655\" data-end=\"3962\"\u003eThese dimensions are especially interesting for projects where wall space is limited. An indoor unit about \u003cstrong data-start=\"3784\" data-end=\"3807\"\u003e33.44 in wide\u003c\/strong\u003e and \u003cstrong data-start=\"3811\" data-end=\"3834\"\u003e11.56 in high\u003c\/strong\u003e can fit more easily in a bedroom, office, or condo than a wider wall unit of 18,000 or 24,000 BTU.\u003c\/p\u003e\n\u003ch1 data-start=\"3964\" data-end=\"4033\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3966\" data-end=\"4033\"\u003eA 9,000 BTU wall-mounted heat pump designed for targeted spaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"4035\" data-end=\"4447\"\u003eThe \u003cstrong data-start=\"4038\" data-end=\"4058\"\u003eZephyr ZE-09CB22\u003c\/strong\u003e is a \u003cstrong data-start=\"4082\" data-end=\"4095\"\u003e9,000 BTU\u003c\/strong\u003e heat pump, making it particularly suitable for small to medium-sized spaces. In reality, the BTU number should never be used alone to choose a device. Insulation, sun exposure, ceiling height, number of windows, air circulation, and actual room use must also be considered.\u003c\/p\u003e\n\u003cp data-start=\"4449\" data-end=\"4870\"\u003eIn a house in Laval, this model can be very suitable for a master bedroom or a closed office. In a condo in Montreal, it can be used for a compact living area or a room that overheats in summer. In Longueuil, on the South Shore or the North Shore, it can also help improve comfort in a specific area that is not well served by the main heating or cooling system.\u003c\/p\u003e\n\u003cp data-start=\"4872\" data-end=\"5421\"\u003e\u003cstrong data-start=\"4872\" data-end=\"4913\"\u003eProper sizing is essential.\u003c\/strong\u003e An oversized heat pump can reach the desired temperature too quickly without properly dehumidifying the air in summer. The result can be a damp cold feeling or uneven comfort. Conversely, an undersized heat pump will run almost continuously and may struggle on very hot or very cold days. The \u003cstrong data-start=\"5283\" data-end=\"5296\"\u003eZE-09CB22\u003c\/strong\u003e model should therefore be selected based on a real analysis of the building, not just a quick estimate of the area.\u003c\/p\u003e\n\u003ch1 data-start=\"5423\" data-end=\"5469\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5425\" data-end=\"5469\"\u003eR32: a modern and efficient refrigerant\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"5471\" data-end=\"5797\"\u003eThe \u003cstrong data-start=\"5474\" data-end=\"5499\"\u003eZephyr CB22 ZE-09CB22\u003c\/strong\u003e operates with \u003cstrong data-start=\"5514\" data-end=\"5533\"\u003eR32 refrigerant\u003c\/strong\u003e, a gas used in several modern wall-mounted heat pumps. For the customer, this detail may seem very technical, but it is important because the refrigerant influences the unit’s design, installation practices, and commissioning requirements.\u003c\/p\u003e\n\u003cp data-start=\"5799\" data-end=\"6133\"\u003eWith a charge of \u003cstrong data-start=\"5818\" data-end=\"5830\"\u003e21.52 oz\u003c\/strong\u003e, the model \u003cstrong data-start=\"5842\" data-end=\"5855\"\u003eZE-09CB22\u003c\/strong\u003e must be installed carefully. Steps like flaring, leak testing, vacuuming, checking pipe length, and commissioning must not be overlooked. \u003cstrong data-start=\"6058\" data-end=\"6133\"\u003eA modern heat pump does not forgive a sloppy installation.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"6135\" data-end=\"6448\"\u003eAt AirGreen, we always take the time to validate the piping route, wall condition, drainage, outdoor clearances, and electrical compliance before confirming an installation. This approach helps avoid performance, noise, leakage, or long-term reliability issues.\u003c\/p\u003e\n\u003ch1 data-start=\"6450\" data-end=\"6506\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6452\" data-end=\"6506\"\u003eEnergy efficiency: 22.5 SEER2 and Energy Star\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"6508\" data-end=\"6817\"\u003eThe model \u003cstrong data-start=\"6518\" data-end=\"6531\"\u003eZE-09CB22\u003c\/strong\u003e shows a performance of \u003cstrong data-start=\"6556\" data-end=\"6570\"\u003e22.5 SEER2\u003c\/strong\u003e, which is an excellent indicator of cooling efficiency. SEER2 measures seasonal cooling efficiency. The higher the value, the more effectively the unit can produce cooling over an entire season.\u003c\/p\u003e\n\u003cp data-start=\"6819\" data-end=\"7218\"\u003eThis model is also rated \u003cstrong data-start=\"6851\" data-end=\"6877\"\u003eEnergy Star V6.1: yes\u003c\/strong\u003e, which adds an important point for owners who want to choose a more efficient unit. For a bedroom, office, or small regularly used space, an efficient heat pump can help reduce energy consumption, especially if it replaces electric baseboards or a less efficient air conditioner.\u003c\/p\u003e\n\u003cp data-start=\"7220\" data-end=\"7582\"\u003eThe \u003cstrong data-start=\"7223\" data-end=\"7237\"\u003eHSPF2 of 9\u003c\/strong\u003e gives an indication of heating efficiency. The \u003cstrong data-start=\"7293\" data-end=\"7316\"\u003eCOP of 3.9 at 8.3 °C\u003c\/strong\u003e means the unit can produce much more thermal energy than it consumes in electricity under favorable conditions. However, as with all heat pumps, the available capacity decreases when the outside temperature drops significantly.\u003c\/p\u003e\n\u003cp data-start=\"7584\" data-end=\"7834\"\u003eAt AirGreen, we always explain these figures in concrete terms. The goal is not for the customer to memorize every indicator, but to understand that \u003cstrong data-start=\"7744\" data-end=\"7833\"\u003eefficiency depends as much on the product as on the installation and proper sizing\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch1 data-start=\"7836\" data-end=\"7902\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"7838\" data-end=\"7902\"\u003eHeating down to -25 °C: what you really need to understand\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"7904\" data-end=\"8213\"\u003eThe Zephyr CB22 brochure presents the series as a heat pump capable of heating down to \u003cstrong data-start=\"7996\" data-end=\"8006\"\u003e-25 °C\u003c\/strong\u003e. This is an important advantage for Quebec winters, especially for customers in Montreal, Laval, Longueuil, the South Shore, and the North Shore who want to use their heat pump for much of the year.\u003c\/p\u003e\n\u003cp data-start=\"8215\" data-end=\"8273\"\u003eFor the \u003cstrong data-start=\"8230\" data-end=\"8243\"\u003eZE-09CB22\u003c\/strong\u003e model, the technical sheet indicates:\u003c\/p\u003e\n\u003cp data-start=\"8275\" data-end=\"8402\"\u003e• \u003cstrong data-start=\"8277\" data-end=\"8314\"\u003e9,000 BTU\/h heating at 8.3 °C\u003c\/strong\u003e\u003cbr data-start=\"8314\" data-end=\"8317\"\u003e• \u003cstrong data-start=\"8319\" data-end=\"8344\"\u003e6,500 BTU\/h at -8.3 °C\u003c\/strong\u003e\u003cbr data-start=\"8344\" data-end=\"8347\"\u003e• \u003cstrong data-start=\"8349\" data-end=\"8373\"\u003e5,400 BTU\/h at -15 °C\u003c\/strong\u003e\u003cbr data-start=\"8373\" data-end=\"8376\"\u003e• \u003cstrong data-start=\"8378\" data-end=\"8402\"\u003e4,000 BTU\/h at -20 °C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"8404\" data-end=\"8723\"\u003eThese figures are very important. They show that the model can continue to operate in cold weather, but capacity decreases as the temperature drops. \u003cstrong data-start=\"8572\" data-end=\"8656\"\u003eHeating down to -25 °C does not mean producing 9,000 BTU continuously at -25 °C.\u003c\/strong\u003e This is an essential distinction to avoid unrealistic expectations.\u003c\/p\u003e\n\u003cp data-start=\"8725\" data-end=\"9055\"\u003eIn a well-insulated room, this model can provide very good comfort for much of the winter. In an older, poorly insulated, heavily windowed, or wind-exposed room, supplementary heating may still be necessary on the coldest days. Our role is to clearly explain this reality before installation.\u003c\/p\u003e\n\u003ch1 data-start=\"9057\" data-end=\"9135\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"9059\" data-end=\"9135\"\u003e4D Mode and Automatic Oscillation: Better Air Distribution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"9137\" data-end=\"9414\"\u003eThe brochure highlights the \u003cstrong data-start=\"9165\" data-end=\"9176\"\u003e4D mode\u003c\/strong\u003e and \u003cstrong data-start=\"9182\" data-end=\"9209\"\u003eautomatic oscillation\u003c\/strong\u003e, two important features to improve air distribution in the room. The goal is to limit cold or hot spots and help the device maintain a more balanced temperature.\u003c\/p\u003e\n\u003cp data-start=\"9416\" data-end=\"9713\"\u003eIn a bedroom, poor positioning can create a direct draft toward the bed. In an office, this can become uncomfortable during working hours. In a small living room, poor diffusion can cool one part of the room while leaving another area too warm.\u003c\/p\u003e\n\u003cp data-start=\"9715\" data-end=\"10144\"\u003eThe \u003cstrong data-start=\"9718\" data-end=\"9729\"\u003e4D mode\u003c\/strong\u003e helps to direct the air more completely, but it does not replace good planning. \u003cstrong data-start=\"9824\" data-end=\"9930\"\u003eThe location of the indoor unit remains one of the most important factors for final comfort.\u003c\/strong\u003e At AirGreen, we always assess the available walls, natural air circulation, furniture placement, ceiling height, and piping constraints before proposing the final location.\u003c\/p\u003e\n\u003ch1 data-start=\"10146\" data-end=\"10197\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10148\" data-end=\"10197\"\u003eInverter technology: more stable comfort\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"10199\" data-end=\"10436\"\u003eVariable frequency technology, also called \u003cstrong data-start=\"10250\" data-end=\"10262\"\u003eInverter\u003c\/strong\u003e, allows the heat pump to adjust its power in real time. Instead of operating only on an on-off basis, the device modulates its effort according to the room’s needs.\u003c\/p\u003e\n\u003cp data-start=\"10438\" data-end=\"10717\"\u003eThis helps reduce temperature fluctuations, improve comfort, and limit energy consumption. A heat pump that runs more gently over long periods can often provide better comfort than a device that constantly starts and stops.\u003c\/p\u003e\n\u003cp data-start=\"10719\" data-end=\"11051\"\u003eFor a model like the \u003cstrong data-start=\"10743\" data-end=\"10756\"\u003eZE-09CB22\u003c\/strong\u003e, this technology is especially useful in rooms where a stable temperature is desired: bedroom, office, playroom, family room, or condo. \u003cstrong data-start=\"10920\" data-end=\"11051\"\u003eComfort comes not only from BTU power but from the device’s ability to maintain a consistent atmosphere.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch1 data-start=\"11053\" data-end=\"11096\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11055\" data-end=\"11096\"\u003eConvenient features for everyday use\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"11098\" data-end=\"11210\"\u003eThe Zephyr CB22 series offers several features designed to make daily use of the device easier:\u003c\/p\u003e\n\u003cp data-start=\"11212\" data-end=\"11846\"\u003e• \u003cstrong data-start=\"11214\" data-end=\"11227\"\u003eNight mode\u003c\/strong\u003e\u003cbr data-start=\"11227\" data-end=\"11230\"\u003e• \u003cstrong data-start=\"11232\" data-end=\"11248\"\u003eSilent mode\u003c\/strong\u003e\u003cbr data-start=\"11248\" data-end=\"11251\"\u003e• \u003cstrong data-start=\"11253\" data-end=\"11267\"\u003eiFeel mode\u003c\/strong\u003e\u003cbr data-start=\"11267\" data-end=\"11270\"\u003e• \u003cstrong data-start=\"11272\" data-end=\"11292\"\u003eQuick start\u003c\/strong\u003e\u003cbr data-start=\"11292\" data-end=\"11295\"\u003e• \u003cstrong data-start=\"11297\" data-end=\"11315\"\u003e24-hour timer\u003c\/strong\u003e\u003cbr data-start=\"11315\" data-end=\"11318\"\u003e• \u003cstrong data-start=\"11320\" data-end=\"11338\"\u003eTurbo function\u003c\/strong\u003e\u003cbr data-start=\"11338\" data-end=\"11341\"\u003e• \u003cstrong data-start=\"11343\" data-end=\"11372\"\u003eLED wireless remote control\u003c\/strong\u003e\u003cbr data-start=\"11372\" data-end=\"11375\"\u003e• \u003cstrong data-start=\"11377\" data-end=\"11396\"\u003eLED dimmer\u003c\/strong\u003e\u003cbr data-start=\"11396\" data-end=\"11399\"\u003e• \u003cstrong data-start=\"11401\" data-end=\"11441\"\u003e5 indoor fan speeds\u003c\/strong\u003e\u003cbr data-start=\"11441\" data-end=\"11444\"\u003e• \u003cstrong data-start=\"11446\" data-end=\"11482\"\u003eDiffuser position memory\u003c\/strong\u003e\u003cbr data-start=\"11482\" data-end=\"11485\"\u003e• \u003cstrong data-start=\"11487\" data-end=\"11512\"\u003eAutomatic cleaning\u003c\/strong\u003e\u003cbr data-start=\"11512\" data-end=\"11515\"\u003e• \u003cstrong data-start=\"11517\" data-end=\"11542\"\u003eAutomatic defrost\u003c\/strong\u003e\u003cbr data-start=\"11542\" data-end=\"11545\"\u003e• \u003cstrong data-start=\"11547\" data-end=\"11585\"\u003eAutomatic 8 °C \/ 46 °F heating\u003c\/strong\u003e\u003cbr data-start=\"11585\" data-end=\"11588\"\u003e• \u003cstrong data-start=\"11590\" data-end=\"11618\"\u003eReversible drain pipe\u003c\/strong\u003e\u003cbr data-start=\"11618\" data-end=\"11621\"\u003e• \u003cstrong data-start=\"11623\" data-end=\"11645\"\u003eTwo-sided drain\u003c\/strong\u003e\u003cbr data-start=\"11645\" data-end=\"11648\"\u003e• \u003cstrong data-start=\"11650\" data-end=\"11679\"\u003eFireproof electrical box\u003c\/strong\u003e\u003cbr data-start=\"11679\" data-end=\"11682\"\u003e• \u003cstrong data-start=\"11684\" data-end=\"11726\"\u003eSelf-adaptive voltage technology\u003c\/strong\u003e\u003cbr data-start=\"11726\" data-end=\"11729\"\u003e• \u003cstrong data-start=\"11731\" data-end=\"11759\"\u003eCompressor heating\u003c\/strong\u003e\u003cbr data-start=\"11759\" data-end=\"11762\"\u003e• \u003cstrong data-start=\"11764\" data-end=\"11796\"\u003eOutdoor unit heating\u003c\/strong\u003e\u003cbr data-start=\"11796\" data-end=\"11799\"\u003e• \u003cstrong data-start=\"11801\" data-end=\"11846\"\u003eHeated chassis for the outdoor unit\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"11848\" data-end=\"12089\"\u003eThe \u003cstrong data-start=\"11851\" data-end=\"11867\"\u003esilent mode\u003c\/strong\u003e is particularly interesting for a bedroom or office. The indoor noise level can drop to \u003cstrong data-start=\"11982\" data-end=\"11994\"\u003e28 dB(A)\u003c\/strong\u003e in silent mode, allowing discreet use during the night or while working.\u003c\/p\u003e\n\u003cp data-start=\"12091\" data-end=\"12392\"\u003eThe \u003cstrong data-start=\"12094\" data-end=\"12108\"\u003eiFeel mode\u003c\/strong\u003e can also improve comfort, as it allows the unit to better adjust its operation according to the temperature sensed around the remote control. This is useful when the temperature near the wall unit does not perfectly reflect the actual temperature in the occupied area.\u003c\/p\u003e\n\u003cp data-start=\"12394\" data-end=\"12735\"\u003eThe \u003cstrong data-start=\"12397\" data-end=\"12422\"\u003eautomatic defrost\u003c\/strong\u003e, \u003cstrong data-start=\"12427\" data-end=\"12455\"\u003ecompressor heating\u003c\/strong\u003e, and \u003cstrong data-start=\"12462\" data-end=\"12493\"\u003eoutdoor heated chassis\u003c\/strong\u003e are also relevant features for Quebec. An outdoor unit must withstand cold, snow, ice, and humidity. These features can help, but they must be accompanied by a well-thought-out outdoor installation.\u003c\/p\u003e\n\u003ch1 data-start=\"12737\" data-end=\"12802\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"12739\" data-end=\"12802\"\u003eElectrical installation: a 208\/230 V model with 15 A MOP\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"12804\" data-end=\"13053\"\u003eThe \u003cstrong data-start=\"12814\" data-end=\"12827\"\u003eZE-09CB22\u003c\/strong\u003e model operates on \u003cstrong data-start=\"12842\" data-end=\"12871\"\u003e208\/230 V, 60 Hz, single phase\u003c\/strong\u003e. The label indicates a \u003cstrong data-start=\"12893\" data-end=\"12909\"\u003eMCA of 9.5 A\u003c\/strong\u003e and a \u003cstrong data-start=\"12916\" data-end=\"12931\"\u003eMOP of 15 A\u003c\/strong\u003e. This information is essential before confirming the project, as it determines the type of electrical circuit required.\u003c\/p\u003e\n\u003cp data-start=\"13055\" data-end=\"13324\"\u003eEven if the unit is a 9,000 BTU heat pump, the electrical part should never be taken lightly. The panel must have enough space, the breaker must be appropriate, the wiring must meet requirements, and the electrical route must be properly planned.\u003c\/p\u003e\n\u003cp data-start=\"13326\" data-end=\"13640\"\u003eIn some older homes in Montreal or Longueuil, the electrical panel may already be fully loaded. In some condos, adding a circuit may require additional verification. At AirGreen, we check these elements before installation to avoid surprises on the day of the work.\u003c\/p\u003e\n\u003ch1 data-start=\"13642\" data-end=\"13709\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"13644\" data-end=\"13709\"\u003e1\/4 - 3\/8 inch piping: a crucial detail in replacement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"13711\" data-end=\"13959\"\u003eThe \u003cstrong data-start=\"13714\" data-end=\"13734\"\u003eZephyr ZE-09CB22\u003c\/strong\u003e uses \u003cstrong data-start=\"13761\" data-end=\"13787\"\u003e1\/4 inch piping for the liquid\u003c\/strong\u003e and \u003cstrong data-start=\"13791\" data-end=\"13813\"\u003e3\/8 inch piping for the gas\u003c\/strong\u003e. This information is especially important when a customer wants to replace an old heat pump by reusing the existing lines.\u003c\/p\u003e\n\u003cp data-start=\"13961\" data-end=\"14203\"\u003eYou should never assume that the old piping is compatible. You need to check the diameter, the condition of the lines, the old refrigerant used, the length of the run, accessibility, and the possibility of properly replacing the lines.\u003c\/p\u003e\n\u003cp data-start=\"14205\" data-end=\"14540\"\u003eThe technical sheet indicates a piping length of \u003cstrong data-start=\"14262\" data-end=\"14279\"\u003e10 to 65 feet\u003c\/strong\u003e, a maximum elevation difference of \u003cstrong data-start=\"14311\" data-end=\"14323\"\u003e50 feet\u003c\/strong\u003e, and a precharge for \u003cstrong data-start=\"14346\" data-end=\"14358\"\u003e25 feet\u003c\/strong\u003e. These limits must be respected to ensure good performance. \u003cstrong data-start=\"14432\" data-end=\"14540\"\u003eImproperly adapted piping can harm efficiency, noise level, reliability, and warranty.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch1 data-start=\"14542\" data-end=\"14608\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"14544\" data-end=\"14608\"\u003eNoise level: a discreet unit for occupied rooms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"14610\" data-end=\"14877\"\u003eThe indoor sound pressure level indicated for the \u003cstrong data-start=\"14668\" data-end=\"14681\"\u003eZE-09CB22\u003c\/strong\u003e model is \u003cstrong data-start=\"14689\" data-end=\"14721\"\u003e45 \/ 40 \/ 32 \/ 30 \/ 28 dB(A)\u003c\/strong\u003e depending on the selected speed. This makes it a unit well suited for spaces where silence is important, such as a bedroom, office, or break room.\u003c\/p\u003e\n\u003cp data-start=\"14879\" data-end=\"15244\"\u003eThe outdoor unit is rated at \u003cstrong data-start=\"14913\" data-end=\"14925\"\u003e53 dB(A)\u003c\/strong\u003e. This level remains reasonable, but the outdoor location must be chosen carefully. In the city, sound can reflect off walls, balconies, fences, or narrow passages. A unit installed too close to a window, a neighbor, or a closed corner may seem louder than it actually is.\u003c\/p\u003e\n\u003cp data-start=\"15246\" data-end=\"15498\"\u003eAt AirGreen, we consider noise, but also maintenance access, drainage, snow, ice, and the stability of the outdoor base. \u003cstrong data-start=\"15407\" data-end=\"15498\"\u003eA good outdoor location protects both comfort and the durability of the unit.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch1 data-start=\"15500\" data-end=\"15588\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"15502\" data-end=\"15588\"\u003eOperating range: air conditioning down to -15 °C and heating down to -25 °C\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"15590\" data-end=\"15850\"\u003eThe brochure indicates an operating range for air conditioning from \u003cstrong data-start=\"15658\" data-end=\"15676\"\u003e-15 °C to 48 °C\u003c\/strong\u003e and for heating from \u003cstrong data-start=\"15696\" data-end=\"15714\"\u003e-25 °C to 24 °C\u003c\/strong\u003e. For Quebec, these figures are relevant because they show that the unit can operate in a wide variety of conditions.\u003c\/p\u003e\n\u003cp data-start=\"15852\" data-end=\"16201\"\u003eAir conditioning down to \u003cstrong data-start=\"15877\" data-end=\"15887\"\u003e-15 °C\u003c\/strong\u003e can be useful for certain specific uses, such as technical rooms or spaces that need cooling even when the outside temperature is cool. For typical residential use, it is mainly the heating capacity down to \u003cstrong data-start=\"16158\" data-end=\"16168\"\u003e-25 °C\u003c\/strong\u003e that interests homeowners.\u003c\/p\u003e\n\u003cp data-start=\"16203\" data-end=\"16512\"\u003eHowever, it is important to keep a realistic view: \u003cstrong data-start=\"16250\" data-end=\"16365\"\u003ethe operating range indicates the limits of operation, not constant capacity at all temperatures\u003c\/strong\u003e. That is why heating data at -8.3 °C, -15 °C, and -20 °C are important to understand the actual behavior of the device in winter.\u003c\/p\u003e\n\u003ch1 data-start=\"16514\" data-end=\"16576\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"16516\" data-end=\"16576\"\u003eHVAC maintenance: preserving efficiency and durability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"16578\" data-end=\"16803\"\u003eA wall-mounted heat pump like the \u003cstrong data-start=\"16610\" data-end=\"16635\"\u003eZephyr CB22 ZE-09CB22\u003c\/strong\u003e must be well maintained to retain its efficiency. Features like automatic cleaning can help, but they do not replace regular maintenance.\u003c\/p\u003e\n\u003cp data-start=\"16805\" data-end=\"16834\"\u003eWe especially recommend:\u003c\/p\u003e\n\u003cp data-start=\"16836\" data-end=\"17284\"\u003e• clean the filters frequently;\u003cbr data-start=\"16871\" data-end=\"16874\"\u003e• ensure the condensation drain flows properly;\u003cbr data-start=\"16933\" data-end=\"16936\"\u003e• keep the indoor unit clean;\u003cbr data-start=\"16971\" data-end=\"16974\"\u003e• monitor for unusual odors or noises;\u003cbr data-start=\"17020\" data-end=\"17023\"\u003e• clear the outdoor unit of snow, leaves, and debris;\u003cbr data-start=\"17092\" data-end=\"17095\"\u003e• check the condition of the outdoor base after winter;\u003cbr data-start=\"17149\" data-end=\"17152\"\u003e• request professional cleaning when performance decreases;\u003cbr data-start=\"17221\" data-end=\"17224\"\u003e• have the unit inspected if defrosting seems abnormal.\u003c\/p\u003e\n\u003cp data-start=\"17286\" data-end=\"17453\"\u003eProper maintenance helps preserve \u003cstrong data-start=\"17327\" data-end=\"17355\"\u003eenergy efficiency\u003c\/strong\u003e, \u003cstrong data-start=\"17357\" data-end=\"17371\"\u003ecomfort\u003c\/strong\u003e, \u003cstrong data-start=\"17373\" data-end=\"17393\"\u003eair quality\u003c\/strong\u003e, \u003cstrong data-start=\"17395\" data-end=\"17415\"\u003enoise level\u003c\/strong\u003e, and \u003cstrong data-start=\"17419\" data-end=\"17438\"\u003ethe lifespan\u003c\/strong\u003e of the device.\u003c\/p\u003e\n\u003ch1 data-start=\"17455\" data-end=\"17519\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"17457\" data-end=\"17519\"\u003eMistakes to avoid before buying a 9,000 BTU heat pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"17521\" data-end=\"17681\"\u003eIn our experience, the most frequent mistakes rarely come from a single technical figure. They usually come from a poor project assessment.\u003c\/p\u003e\n\u003cp data-start=\"17683\" data-end=\"17711\"\u003eHere are the mistakes to avoid:\u003c\/p\u003e\n\u003cp data-start=\"17713\" data-end=\"18254\"\u003e• choosing a 9,000 BTU unit solely based on area;\u003cbr data-start=\"17768\" data-end=\"17771\"\u003e• ignoring window orientation;\u003cbr data-start=\"17808\" data-end=\"17811\"\u003e• neglecting insulation;\u003cbr data-start=\"17834\" data-end=\"17837\"\u003e• forgetting the ceiling height;\u003cbr data-start=\"17869\" data-end=\"17872\"\u003e• placing the indoor unit only to hide the piping;\u003cbr data-start=\"17936\" data-end=\"17939\"\u003e• blowing air directly towards the bed, sofa, or desk;\u003cbr data-start=\"17996\" data-end=\"17999\"\u003e• assuming the old refrigerant lines are compatible;\u003cbr data-start=\"18066\" data-end=\"18069\"\u003e• forgetting electrical verification;\u003cbr data-start=\"18106\" data-end=\"18109\"\u003e• installing the outdoor unit too low for winter;\u003cbr data-start=\"18162\" data-end=\"18165\"\u003e• neglecting drainage;\u003cbr data-start=\"18188\" data-end=\"18191\"\u003e• buying based only on price without validating actual comfort.\u003c\/p\u003e\n\u003cp data-start=\"18256\" data-end=\"18450\"\u003eAt AirGreen, we prefer to clarify these points before installation. This helps avoid unpleasant surprises and ensures a more durable, cleaner, and more comfortable installation.\u003c\/p\u003e\n\u003ch1 data-start=\"18452\" data-end=\"18518\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"18454\" data-end=\"18518\"\u003eWhy choose AirGreen to install the Zephyr ZE-09CB22\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"18520\" data-end=\"18794\"\u003eAirGreen is a company specializing in \u003cstrong data-start=\"18563\" data-end=\"18571\"\u003eHVAC\u003c\/strong\u003e that installs, maintains, and repairs wall-mounted, central, and multi-zone heat pump systems in Greater Montreal. We regularly operate in \u003cstrong data-start=\"18726\" data-end=\"18793\"\u003eMontreal, Laval, Longueuil, on the South Shore and the North Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"18796\" data-end=\"18846\"\u003eBy choosing AirGreen, customers benefit from:\u003c\/p\u003e\n\u003cp data-start=\"18848\" data-end=\"19365\"\u003e• a clear evaluation before work begins;\u003cbr data-start=\"18892\" data-end=\"18895\"\u003e• sizing adapted to the room;\u003cbr data-start=\"18936\" data-end=\"18939\"\u003e• a thorough electrical inspection;\u003cbr data-start=\"18980\" data-end=\"18983\"\u003e• an installation compliant with technical requirements;\u003cbr data-start=\"19038\" data-end=\"19041\"\u003e• special attention to the aesthetics of the installation path;\u003cbr data-start=\"19099\" data-end=\"19102\"\u003e• good positioning of the indoor unit;\u003cbr data-start=\"19150\" data-end=\"19153\"\u003e• an outdoor location designed for winter;\u003cbr data-start=\"19201\" data-end=\"19204\"\u003e• simple explanations on how to use the device;\u003cbr data-start=\"19261\" data-end=\"19264\"\u003e• a structured after-sales service;\u003cbr data-start=\"19301\" data-end=\"19304\"\u003e• a team familiar with the realities of Quebec buildings.\u003c\/p\u003e\n\u003cp data-start=\"19367\" data-end=\"19668\"\u003eWe know a heat pump is a significant investment, even when it’s a 9,000 BTU model. Our goal is for the customer to understand what they are buying, why this model is recommended, how it will be installed, and how it should be used to deliver its best performance.\u003c\/p\u003e\n\u003ch1 data-start=\"19670\" data-end=\"19747\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"19672\" data-end=\"19747\"\u003eAn efficient, compact HVAC solution well suited to targeted needs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"19749\" data-end=\"20220\"\u003eThe \u003cstrong data-start=\"19752\" data-end=\"19800\"\u003eZephyr CB22 R32 ZE-09CB22 Wall Heat Pump\u003c\/strong\u003e is an interesting choice for homeowners looking for a compact, efficient wall heat pump capable of providing good comfort year-round. With its \u003cstrong data-start=\"19968\" data-end=\"19981\"\u003e9,000 BTU\u003c\/strong\u003e, \u003cstrong data-start=\"19987\" data-end=\"20004\"\u003eSEER2 of 22.5\u003c\/strong\u003e, \u003cstrong data-start=\"20010\" data-end=\"20030\"\u003eEnergy Star V6.1\u003c\/strong\u003e, operation on \u003cstrong data-start=\"20054\" data-end=\"20061\"\u003eR32\u003c\/strong\u003e, indoor noise level as low as \u003cstrong data-start=\"20111\" data-end=\"20123\"\u003e28 dB(A)\u003c\/strong\u003e, and heating capacity down to \u003cstrong data-start=\"20160\" data-end=\"20170\"\u003e-25 °C\u003c\/strong\u003e, it meets the needs of targeted rooms well.\u003c\/p\u003e\n\u003cp data-start=\"20222\" data-end=\"20604\"\u003eHowever, it requires a serious installation. The electrical circuit \u003cstrong data-start=\"20294\" data-end=\"20307\"\u003e208\/230 V\u003c\/strong\u003e, piping \u003cstrong data-start=\"20323\" data-end=\"20339\"\u003e1\/4 - 3\/8 in\u003c\/strong\u003e, clearances, drainage, wall positioning, and outdoor location must be verified before confirming the project. It’s exactly this kind of detail that distinguishes an ordinary installation from a durable, comfortable, and well-thought-out one.\u003c\/p\u003e\n\u003cp data-start=\"20606\" data-end=\"20944\"\u003eTo get a clear quote, compare this model with other Zephyr options, or schedule an installation in \u003cstrong data-start=\"20723\" data-end=\"20786\"\u003eMontreal, Laval, Longueuil, on the South Shore or the North Shore\u003c\/strong\u003e, contact AirGreen now. Our team will help you choose the right HVAC solution based on your building, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665925390628,"sku":"ZE-09CB22I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRCB22R32GRANDMONTREAL_1ef5ae81-7d25-4988-a139-2de2c08116aa.png?v=1783695952"},{"product_id":"thermopompe-murale-zephyr-cb22-r32-12000-btu-montreal-laval-rive-sud","title":"ZEPHYR CB22 R32 Wall Heat Pump | 12000 BTU | Montreal, Laval, South Shore","description":"\u003ch1 data-start=\"0\" data-end=\"59\" class=\"PDq2pG_selectionAnchorContainer\"\u003eZephyr CB22 R32 12,000 BTU Wall-Mounted Heat Pump — ZE-12CB22\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2 data-start=\"61\" data-end=\"155\"\u003eA simple, efficient 12,000 BTU wall-mounted heat pump well suited to residential needs\u003c\/h2\u003e\n\u003cp data-start=\"157\" data-end=\"512\"\u003eThe \u003cstrong data-start=\"160\" data-end=\"209\"\u003eZephyr CB22 R32 12,000 BTU wall-mounted heat pump\u003c\/strong\u003e, model \u003cstrong data-start=\"218\" data-end=\"231\"\u003eZE-12CB22\u003c\/strong\u003e, is aimed at homeowners looking for a reliable HVAC solution to cool and heat a living room, condo, master bedroom, office, small business, or residential area where comfort must remain stable without installing a full central system.\u003c\/p\u003e\n\u003cp data-start=\"514\" data-end=\"934\"\u003eAt AirGreen, we recommend this type of unit when the customer wants an affordable, compact, discreet wall-mounted heat pump capable of meeting the essential needs of the Quebec climate. The \u003cstrong data-start=\"717\" data-end=\"730\"\u003eZE-12CB22\u003c\/strong\u003e is not designed for very large open spaces like an 18,000 or 24,000 BTU unit, but it can be an excellent choice when properly sized for the room to be treated.\u003c\/p\u003e\n\u003cp data-start=\"936\" data-end=\"1319\"\u003eThis model stands out for several important features: its \u003cstrong data-start=\"1010\" data-end=\"1041\"\u003e12,000 BTU cooling capacity\u003c\/strong\u003e, operation with \u003cstrong data-start=\"1065\" data-end=\"1084\"\u003eR32 refrigerant\u003c\/strong\u003e, power supply of \u003cstrong data-start=\"1106\" data-end=\"1121\"\u003e208V \/ 230V\u003c\/strong\u003e, \u003cstrong data-start=\"1127\" data-end=\"1155\"\u003eheating down to -25 °C\u003c\/strong\u003e, \u003cstrong data-start=\"1161\" data-end=\"1177\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"1183\" data-end=\"1196\"\u003enight mode\u003c\/strong\u003e, \u003cstrong data-start=\"1202\" data-end=\"1216\"\u003eiFeel mode\u003c\/strong\u003e, \u003cstrong data-start=\"1222\" data-end=\"1249\"\u003eautomatic oscillation\u003c\/strong\u003e, \u003cstrong data-start=\"1255\" data-end=\"1266\"\u003e4D mode\u003c\/strong\u003e, and a basic warranty of \u003cstrong data-start=\"1293\" data-end=\"1318\"\u003e10 years on parts\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1321\" data-end=\"1716\"\u003eThe Zephyr CB22 R32 heat pump deserves serious analysis before installation. You need to consider the actual room size, ceiling height, insulation, window orientation, sun exposure, air circulation, indoor unit location, distance from the outdoor unit, drainage, outdoor clearances, and electrical panel capacity.\u003c\/p\u003e\n\u003cp data-start=\"1718\" data-end=\"2107\"\u003eAt AirGreen, we have installed enough wall-mounted heat pumps in Montreal, Laval, Longueuil, on the South Shore and the North Shore to know that a \u003cstrong data-start=\"1873\" data-end=\"1887\"\u003e12,000 BTU\u003c\/strong\u003e unit can provide excellent comfort when installed in the right place. Conversely, even an efficient device can disappoint if it is poorly placed, improperly sized, or installed without considering the building’s realities.\u003c\/p\u003e\n\u003ch2 data-start=\"2109\" data-end=\"2167\"\u003eImportant technical characteristics to know\u003c\/h2\u003e\n\u003cp data-start=\"2169\" data-end=\"2331\"\u003eFor model \u003cstrong data-start=\"2184\" data-end=\"2197\"\u003eZE-12CB22\u003c\/strong\u003e, the Zephyr CB22 brochure datasheet provides the following key information:\u003c\/p\u003e\n\u003cp data-start=\"2333\" data-end=\"3953\"\u003e• \u003cstrong data-start=\"2335\" data-end=\"2354\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"2354\" data-end=\"2357\"\u003e• \u003cstrong data-start=\"2359\" data-end=\"2375\"\u003eSeries: CB22\u003c\/strong\u003e\u003cbr data-start=\"2375\" data-end=\"2378\"\u003e• \u003cstrong data-start=\"2380\" data-end=\"2402\"\u003eModel: ZE-12CB22\u003c\/strong\u003e\u003cbr data-start=\"2402\" data-end=\"2405\"\u003e• \u003cstrong data-start=\"2407\" data-end=\"2436\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"2436\" data-end=\"2439\"\u003e• \u003cstrong data-start=\"2441\" data-end=\"2462\"\u003eRefrigerant: R32\u003c\/strong\u003e\u003cbr data-start=\"2462\" data-end=\"2465\"\u003e• \u003cstrong data-start=\"2467\" data-end=\"2521\"\u003eCooling capacity at 35 °C: 12,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2521\" data-end=\"2524\"\u003e• \u003cstrong data-start=\"2526\" data-end=\"2575\"\u003eHeating capacity at 8.3 °C: 12,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2575\" data-end=\"2578\"\u003e• \u003cstrong data-start=\"2580\" data-end=\"2594\"\u003eSEER2: 20\u003c\/strong\u003e\u003cbr data-start=\"2594\" data-end=\"2597\"\u003e• \u003cstrong data-start=\"2599\" data-end=\"2615\"\u003eHSPF2 IV: 9\u003c\/strong\u003e\u003cbr data-start=\"2615\" data-end=\"2618\"\u003e• \u003cstrong data-start=\"2620\" data-end=\"2641\"\u003eEER2: 10.5 BTU\/W\u003c\/strong\u003e\u003cbr data-start=\"2641\" data-end=\"2644\"\u003e• \u003cstrong data-start=\"2646\" data-end=\"2678\"\u003eHeating COP at 8.3 °C: 3.5\u003c\/strong\u003e\u003cbr data-start=\"2678\" data-end=\"2681\"\u003e• \u003cstrong data-start=\"2683\" data-end=\"2714\"\u003eCOP2 heating: 12.0 BTU\/W\u003c\/strong\u003e\u003cbr data-start=\"2714\" data-end=\"2717\"\u003e• \u003cstrong data-start=\"2719\" data-end=\"2777\"\u003eNominal heating capacity at -8.3 °C: 9,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2777\" data-end=\"2780\"\u003e• \u003cstrong data-start=\"2782\" data-end=\"2839\"\u003eMaximum heating capacity at -15 °C: 7,500 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2839\" data-end=\"2842\"\u003e• \u003cstrong data-start=\"2844\" data-end=\"2866\"\u003eCOP at -15 °C: 2.0\u003c\/strong\u003e\u003cbr data-start=\"2866\" data-end=\"2869\"\u003e• \u003cstrong data-start=\"2871\" data-end=\"2928\"\u003eMaximum heating capacity at -20 °C: 6,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2928\" data-end=\"2931\"\u003e• \u003cstrong data-start=\"2933\" data-end=\"2959\"\u003eEnergy Star V6.1: no\u003c\/strong\u003e\u003cbr data-start=\"2959\" data-end=\"2962\"\u003e• \u003cstrong data-start=\"2964\" data-end=\"3005\"\u003eIndoor airflow: 253 to 400 CFM\u003c\/strong\u003e\u003cbr data-start=\"3005\" data-end=\"3008\"\u003e• \u003cstrong data-start=\"3010\" data-end=\"3056\"\u003eRefrigerant charge volume: 21.87 oz\u003c\/strong\u003e\u003cbr data-start=\"3056\" data-end=\"3059\"\u003e• \u003cstrong data-start=\"3061\" data-end=\"3128\"\u003eIndoor sound pressure: 46 \/ 40 \/ 32.5 \/ 30 \/ 28 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"3128\" data-end=\"3131\"\u003e• \u003cstrong data-start=\"3133\" data-end=\"3178\"\u003eOutdoor sound pressure: 53 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"3178\" data-end=\"3181\"\u003e• \u003cstrong data-start=\"3183\" data-end=\"3224\"\u003eVoltage: 208V \/ 230V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"3224\" data-end=\"3227\"\u003e• \u003cstrong data-start=\"3229\" data-end=\"3273\"\u003eNominal cooling current: 5.2 A\u003c\/strong\u003e\u003cbr data-start=\"3273\" data-end=\"3276\"\u003e• \u003cstrong data-start=\"3278\" data-end=\"3318\"\u003eNominal heating current: 4.8 A\u003c\/strong\u003e\u003cbr data-start=\"3318\" data-end=\"3321\"\u003e• \u003cstrong data-start=\"3323\" data-end=\"3338\"\u003eMCA: 9.5 A\u003c\/strong\u003e\u003cbr data-start=\"3338\" data-end=\"3341\"\u003e• \u003cstrong data-start=\"3343\" data-end=\"3357\"\u003eMOP: 15 A\u003c\/strong\u003e\u003cbr data-start=\"3357\" data-end=\"3360\"\u003e• \u003cstrong data-start=\"3362\" data-end=\"3428\"\u003eRequired communication wire: 4\/14 copper multi-strand 600V\u003c\/strong\u003e\u003cbr data-start=\"3428\" data-end=\"3431\"\u003e• \u003cstrong data-start=\"3433\" data-end=\"3464\"\u003eLiquid piping: 1\/4 inch\u003c\/strong\u003e\u003cbr data-start=\"3464\" data-end=\"3467\"\u003e• \u003cstrong data-start=\"3469\" data-end=\"3496\"\u003eGas piping: 3\/8 in\u003c\/strong\u003e\u003cbr data-start=\"3496\" data-end=\"3499\"\u003e• \u003cstrong data-start=\"3501\" data-end=\"3551\"\u003ePiping length min-max: 10 to 65 feet\u003c\/strong\u003e\u003cbr data-start=\"3551\" data-end=\"3554\"\u003e• \u003cstrong data-start=\"3556\" data-end=\"3593\"\u003eMaximum elevation difference: 50 feet\u003c\/strong\u003e\u003cbr data-start=\"3593\" data-end=\"3596\"\u003e• \u003cstrong data-start=\"3598\" data-end=\"3634\"\u003ePrecharge length: 25 feet\u003c\/strong\u003e\u003cbr data-start=\"3634\" data-end=\"3637\"\u003e• \u003cstrong data-start=\"3639\" data-end=\"3707\"\u003eIndoor unit dimensions: 33 7\/16 × 11 9\/16 × 8 1\/16 in\u003c\/strong\u003e\u003cbr data-start=\"3707\" data-end=\"3710\"\u003e• \u003cstrong data-start=\"3712\" data-end=\"3777\"\u003eOutdoor unit dimensions: 28 1\/8 × 21 1\/4 × 9 1\/2 in\u003c\/strong\u003e\u003cbr data-start=\"3777\" data-end=\"3780\"\u003e• \u003cstrong data-start=\"3782\" data-end=\"3843\"\u003eCooling operating range: -15 °C to 48 °C\u003c\/strong\u003e\u003cbr data-start=\"3843\" data-end=\"3846\"\u003e• \u003cstrong data-start=\"3848\" data-end=\"3905\"\u003eHeating operating range: -25 °C to 24 °C\u003c\/strong\u003e\u003cbr data-start=\"3905\" data-end=\"3908\"\u003e• \u003cstrong data-start=\"3910\" data-end=\"3953\"\u003eZephyr basic warranty: 10 years parts\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3955\" data-end=\"4381\"\u003eThese figures are not just technical data. They directly influence the feasibility of the project, the choice of circuit breaker, the routing of piping, the actual performance of the device, and the installation cost. For example, the model \u003cstrong data-start=\"4208\" data-end=\"4247\"\u003eZE-12CB22 operates at 208V \/ 230V\u003c\/strong\u003e, with a \u003cstrong data-start=\"4257\" data-end=\"4272\"\u003eMOP of 15 A\u003c\/strong\u003e and a \u003cstrong data-start=\"4279\" data-end=\"4295\"\u003eMCA of 9.5 A\u003c\/strong\u003e. This means the electrical supply must be checked before installation.\u003c\/p\u003e\n\u003ch2 data-start=\"4383\" data-end=\"4434\"\u003eA capacity of 12,000 BTU: for which spaces?\u003c\/h2\u003e\n\u003cp data-start=\"4436\" data-end=\"4734\"\u003eA wall-mounted heat pump of \u003cstrong data-start=\"4462\" data-end=\"4476\"\u003e12,000 BTU\u003c\/strong\u003e is often chosen for medium-sized spaces. It can suit a main room, a bedroom, an office, a condo, a family room, or a semi-open area, but the BTU number alone is never enough to confirm the right choice.\u003c\/p\u003e\n\u003cp data-start=\"4736\" data-end=\"4779\"\u003eWe always evaluate several elements:\u003c\/p\u003e\n\u003cp data-start=\"4781\" data-end=\"5213\"\u003e• \u003cstrong data-start=\"4783\" data-end=\"4832\"\u003ethe actual area to be cooled or heated\u003c\/strong\u003e;\u003cbr data-start=\"4833\" data-end=\"4836\"\u003e• \u003cstrong data-start=\"4838\" data-end=\"4865\"\u003ethe ceiling height\u003c\/strong\u003e;\u003cbr data-start=\"4866\" data-end=\"4869\"\u003e• \u003cstrong data-start=\"4871\" data-end=\"4898\"\u003ethe building insulation\u003c\/strong\u003e;\u003cbr data-start=\"4899\" data-end=\"4902\"\u003e• \u003cstrong data-start=\"4904\" data-end=\"4934\"\u003ethe orientation of the windows\u003c\/strong\u003e;\u003cbr data-start=\"4935\" data-end=\"4938\"\u003e• \u003cstrong data-start=\"4940\" data-end=\"4975\"\u003ethe solar load in the afternoon\u003c\/strong\u003e;\u003cbr data-start=\"4976\" data-end=\"4979\"\u003e• \u003cstrong data-start=\"4981\" data-end=\"5023\"\u003ethe level of openness between rooms\u003c\/strong\u003e;\u003cbr data-start=\"5024\" data-end=\"5027\"\u003e• \u003cstrong data-start=\"5029\" data-end=\"5054\"\u003ethe number of occupants\u003c\/strong\u003e;\u003cbr data-start=\"5055\" data-end=\"5058\"\u003e• \u003cstrong data-start=\"5060\" data-end=\"5089\"\u003ethe use of the room\u003c\/strong\u003e;\u003cbr data-start=\"5090\" data-end=\"5093\"\u003e• \u003cstrong data-start=\"5095\" data-end=\"5135\"\u003ethe presence of a supplementary heater\u003c\/strong\u003e;\u003cbr data-start=\"5136\" data-end=\"5139\"\u003e• \u003cstrong data-start=\"5141\" data-end=\"5212\"\u003ethe possible distance between the indoor unit and the outdoor unit\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"5215\" data-end=\"5624\"\u003eIn a Montreal condo, the \u003cstrong data-start=\"5244\" data-end=\"5257\"\u003eZE-12CB22\u003c\/strong\u003e can be very interesting for a well-configured main area. In a house in Laval, it can be ideal for a master bedroom, a closed living room, or a home office. In Longueuil, on the South Shore or the North Shore, it can also suit a renovated space where you want to improve comfort without changing the entire existing heating system.\u003c\/p\u003e\n\u003cp data-start=\"5626\" data-end=\"6097\"\u003eA common mistake is choosing a heat pump simply because it seems “strong enough.” An overly powerful unit can reach the temperature too quickly in cooling mode, reduce dehumidification time, and create less stable comfort. Conversely, an underpowered unit will run for a long time without maintaining the desired temperature on very hot or very cold days. \u003cstrong data-start=\"6049\" data-end=\"6097\"\u003eProper sizing remains essential.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"6099\" data-end=\"6174\"\u003eR32 refrigerant: a modern technology for HVAC installations\u003c\/h2\u003e\n\u003cp data-start=\"6176\" data-end=\"6438\"\u003eThe Zephyr CB22 series uses \u003cstrong data-start=\"6208\" data-end=\"6227\"\u003eR32 refrigerant\u003c\/strong\u003e. This refrigerant is increasingly common in modern wall-mounted heat pumps because it allows manufacturers to design efficient, compact units suited to the new HVAC market requirements.\u003c\/p\u003e\n\u003cp data-start=\"6440\" data-end=\"6838\"\u003eFor the customer, the type of refrigerant may seem secondary, but it impacts the design of the unit, installation methods, tools used, and best practices to follow. An R32 installation must be done cleanly, with particular attention to connection quality, leak testing, vacuuming, and adherence to piping lengths.\u003c\/p\u003e\n\u003cp data-start=\"6840\" data-end=\"7183\"\u003eAt AirGreen, we always emphasize these steps. A modern heat pump should not be installed hastily. \u003cstrong data-start=\"6957\" data-end=\"7048\"\u003eProper flare, clean piping, thorough vacuuming, and a complete startup\u003c\/strong\u003e make all the difference between a durable installation and one that may cause problems after a few seasons.\u003c\/p\u003e\n\u003ch2 data-start=\"7185\" data-end=\"7239\"\u003eHeating down to -25 °C: what you need to understand\u003c\/h2\u003e\n\u003cp data-start=\"7241\" data-end=\"7569\"\u003eThe brochure presents the Zephyr CB22 as a heat pump capable of providing heating down to an outdoor temperature of \u003cstrong data-start=\"7369\" data-end=\"7379\"\u003e-25 °C\u003c\/strong\u003e. This is a very interesting point for Quebec, especially for customers who want to reduce the use of electric baseboards or improve the comfort of a specific area of the home.\u003c\/p\u003e\n\u003cp data-start=\"7571\" data-end=\"7960\"\u003eFor the model \u003cstrong data-start=\"7586\" data-end=\"7599\"\u003eZE-12CB22\u003c\/strong\u003e, the datasheet indicates a heating capacity of \u003cstrong data-start=\"7647\" data-end=\"7672\"\u003e12,000 BTU\/h at 8.3 °C\u003c\/strong\u003e, a nominal capacity of \u003cstrong data-start=\"7699\" data-end=\"7724\"\u003e9,000 BTU\/h at -8.3 °C\u003c\/strong\u003e, a maximum capacity of \u003cstrong data-start=\"7751\" data-end=\"7775\"\u003e7,500 BTU\/h at -15 °C\u003c\/strong\u003e, and a maximum capacity of \u003cstrong data-start=\"7804\" data-end=\"7828\"\u003e6,000 BTU\/h at -20 °C\u003c\/strong\u003e. These figures are very important because they show that the available power decreases as the outdoor temperature drops.\u003c\/p\u003e\n\u003cp data-start=\"7962\" data-end=\"8338\"\u003eThis does not mean the device is not useful in winter. On the contrary, a well-chosen wall-mounted heat pump can provide a large part of the heating in a well-insulated area. However, it is important to remain realistic: \u003cstrong data-start=\"8183\" data-end=\"8258\"\u003eat very low temperatures, supplementary heating may still be necessary\u003c\/strong\u003e, especially in older, poorly insulated, or very windy homes.\u003c\/p\u003e\n\u003cp data-start=\"8340\" data-end=\"8657\"\u003eAt AirGreen, we always explain this reality before installation. The goal is not to sell an exaggerated promise but to offer an HVAC solution well suited to the building. The \u003cstrong data-start=\"8530\" data-end=\"8543\"\u003eZE-12CB22\u003c\/strong\u003e can be an excellent choice to improve winter comfort, provided its real capabilities are understood.\u003c\/p\u003e\n\u003ch2 data-start=\"8659\" data-end=\"8722\"\u003eAir conditioning down to -15 °C: useful in certain contexts\u003c\/h2\u003e\n\u003cp data-start=\"8724\" data-end=\"8990\"\u003eThe brochure also states that the air conditioning mode can cool down to an outdoor temperature of \u003cstrong data-start=\"8838\" data-end=\"8848\"\u003e-15 °C\u003c\/strong\u003e. For a residential owner, this information may seem less important, but it can be useful in certain specific contexts.\u003c\/p\u003e\n\u003cp data-start=\"8992\" data-end=\"9402\"\u003eSome spaces require cooling even when the outdoor temperature is cool: rooms with many electronic devices, small shops, offices, light server rooms, highly glazed areas, or spaces that accumulate heat due to sun exposure. In these cases, the ability to operate cooling at low outdoor temperatures can be an advantage.\u003c\/p\u003e\n\u003cp data-start=\"9404\" data-end=\"9592\"\u003eFor typical residential use, this feature is not always decisive, but it shows that the device was designed to offer good operational flexibility.\u003c\/p\u003e\n\u003ch2 data-start=\"9594\" data-end=\"9652\"\u003eEnergy efficiency: interpreting the numbers correctly\u003c\/h2\u003e\n\u003cp data-start=\"9654\" data-end=\"9853\"\u003eThe model \u003cstrong data-start=\"9664\" data-end=\"9677\"\u003eZE-12CB22\u003c\/strong\u003e features a \u003cstrong data-start=\"9689\" data-end=\"9704\"\u003eSEER2 of 20\u003c\/strong\u003e and a \u003cstrong data-start=\"9711\" data-end=\"9728\"\u003eHSPF2 IV of 9\u003c\/strong\u003e. These figures are used to assess the energy efficiency of the device, but they must be understood in context.\u003c\/p\u003e\n\u003cp data-start=\"9855\" data-end=\"10313\"\u003eThe \u003cstrong data-start=\"9858\" data-end=\"9867\"\u003eSEER2\u003c\/strong\u003e measures seasonal cooling efficiency. The higher this number, the more efficient the device is over a cooling season. The \u003cstrong data-start=\"10012\" data-end=\"10021\"\u003eHSPF2\u003c\/strong\u003e relates to heating efficiency over a season. The \u003cstrong data-start=\"10076\" data-end=\"10084\"\u003eEER2\u003c\/strong\u003e, indicated at \u003cstrong data-start=\"10096\" data-end=\"10110\"\u003e10.5 BTU\/W\u003c\/strong\u003e, provides a measure of cooling efficiency under specific conditions. The \u003cstrong data-start=\"10192\" data-end=\"10199\"\u003eCOP\u003c\/strong\u003e, indicated at \u003cstrong data-start=\"10211\" data-end=\"10227\"\u003e3.5 to 8.3 °C\u003c\/strong\u003e, represents the ratio between thermal energy produced and electricity consumed.\u003c\/p\u003e\n\u003cp data-start=\"10315\" data-end=\"10605\"\u003eFor a customer, the goal is not to memorize every indicator but to understand that these data influence electricity consumption. A well-used heat pump can help reduce energy costs, especially when it replaces part of direct electric heating.\u003c\/p\u003e\n\u003cp data-start=\"10607\" data-end=\"11110\"\u003eIt is also important to note: \u003cstrong data-start=\"10648\" data-end=\"10726\"\u003ethe technical sheet indicates Energy Star V6.1: no for the ZE-12CB22 model\u003c\/strong\u003e. This does not mean the device is ineffective, but it means it should not be presented as an Energy Star model according to the technical line specified for this capacity. At AirGreen, we always prefer to clarify this type of information before purchase to avoid any confusion regarding subsidies, certifications, or eligibility for certain programs.\u003c\/p\u003e\n\u003ch2 data-start=\"11112\" data-end=\"11172\"\u003eIndoor comfort: silent mode, night mode, and iFeel mode\u003c\/h2\u003e\n\u003cp data-start=\"11174\" data-end=\"11533\"\u003eThe brochure highlights several features focused on daily comfort. The \u003cstrong data-start=\"11259\" data-end=\"11272\"\u003eZE-12CB22\u003c\/strong\u003e notably offers \u003cstrong data-start=\"11294\" data-end=\"11310\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"11315\" data-end=\"11328\"\u003enight mode\u003c\/strong\u003e, \u003cstrong data-start=\"11333\" data-end=\"11347\"\u003eiFeel mode\u003c\/strong\u003e, \u003cstrong data-start=\"11352\" data-end=\"11372\"\u003equick start\u003c\/strong\u003e, \u003cstrong data-start=\"11377\" data-end=\"11394\"\u003e24-hour timer\u003c\/strong\u003e, \u003cstrong data-start=\"11399\" data-end=\"11423\"\u003ebase heating\u003c\/strong\u003e, \u003cstrong data-start=\"11428\" data-end=\"11456\"\u003ecompressor heating\u003c\/strong\u003e, \u003cstrong data-start=\"11461\" data-end=\"11483\"\u003etwo-sided drain\u003c\/strong\u003e, and \u003cstrong data-start=\"11490\" data-end=\"11532\"\u003eauto-adaptive voltage technology\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"11535\" data-end=\"12041\"\u003eThe \u003cstrong data-start=\"11538\" data-end=\"11554\"\u003esilent mode\u003c\/strong\u003e is particularly interesting for a bedroom, office, or room where noise must remain discreet. The sheet indicates an indoor sound pressure level that can drop to \u003cstrong data-start=\"11740\" data-end=\"11752\"\u003e28 dB(A)\u003c\/strong\u003e in silent mode, with levels of \u003cstrong data-start=\"11790\" data-end=\"11824\"\u003e46 \/ 40 \/ 32.5 \/ 30 \/ 28 dB(A)\u003c\/strong\u003e depending on speeds. For a wall-mounted heat pump, this is an important point, as comfort is not limited to temperature. Noise, airflow direction, and operational stability also play a role.\u003c\/p\u003e\n\u003cp data-start=\"12043\" data-end=\"12396\"\u003eThe \u003cstrong data-start=\"12046\" data-end=\"12059\"\u003enight mode\u003c\/strong\u003e allows the device’s operation to be adapted during sleeping hours, while \u003cstrong data-start=\"12154\" data-end=\"12168\"\u003eiFeel mode\u003c\/strong\u003e helps better adjust the temperature according to the area where the remote control is located. This feature can be useful when the temperature near the wall unit is not exactly the same as that felt in the occupied area.\u003c\/p\u003e\n\u003ch2 data-start=\"12398\" data-end=\"12473\"\u003eAutomatic oscillation and 4D mode: better air distribution\u003c\/h2\u003e\n\u003cp data-start=\"12475\" data-end=\"12701\"\u003eThe brochure also presents \u003cstrong data-start=\"12504\" data-end=\"12531\"\u003eautomatic oscillation\u003c\/strong\u003e and \u003cstrong data-start=\"12538\" data-end=\"12549\"\u003e4D mode\u003c\/strong\u003e, designed to better distribute air in the room. The goal is to achieve a more balanced temperature and reduce cold or hot spots.\u003c\/p\u003e\n\u003cp data-start=\"12703\" data-end=\"13069\"\u003eIn practice, this feature is very important. A wall-mounted heat pump heats or cools not only by its power but also by its ability to move air properly. If the unit is poorly placed, the air may remain concentrated in one area. If it is well installed and well oriented, it can improve comfort throughout the room.\u003c\/p\u003e\n\u003cp data-start=\"13071\" data-end=\"13441\"\u003eThe brochure also mentions that variable frequency technology allows the heat pump to adjust its power in real time. This technology helps reduce temperature fluctuations and limit energy consumption. \u003cstrong data-start=\"13308\" data-end=\"13441\"\u003eInstead of constantly operating at full power, the device can modulate its output according to the actual needs of the room.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"13443\" data-end=\"13508\"\u003eIndoor unit installation: location changes everything\u003c\/h2\u003e\n\u003cp data-start=\"13510\" data-end=\"13770\"\u003eFor a wall-mounted heat pump like the \u003cstrong data-start=\"13547\" data-end=\"13560\"\u003eZE-12CB22\u003c\/strong\u003e, the location of the indoor unit is a determining factor. The device must be installed to distribute air efficiently, without blowing directly on occupants for long periods.\u003c\/p\u003e\n\u003cp data-start=\"13772\" data-end=\"14347\"\u003eWe pay special attention to available walls, windows, stairs, low ceilings, tall furniture, corridors, doors, and passage areas. In many Montreal homes, brick walls, plaster ceilings, or narrow divisions can complicate location choice. In houses in Laval, Longueuil, the South Shore, or the North Shore, the layout is often different, but the same principles apply: \u003cstrong data-start=\"14258\" data-end=\"14347\"\u003ethe unit must be placed for comfort, not just to facilitate piping.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"14349\" data-end=\"14661\"\u003eThe indoor unit dimensions are \u003cstrong data-start=\"14394\" data-end=\"14427\"\u003e33 7\/16 × 11 9\/16 × 8 1\/16 inches\u003c\/strong\u003e. This relatively compact size allows integration into several rooms, but necessary clearances must still be planned for maintenance, panel opening, filter cleaning, and air circulation.\u003c\/p\u003e\n\u003ch2 data-start=\"14663\" data-end=\"14739\"\u003eOutdoor unit installation: clearance, noise, and Quebec winter\u003c\/h2\u003e\n\u003cp data-start=\"14741\" data-end=\"14989\"\u003eThe outdoor unit of the \u003cstrong data-start=\"14766\" data-end=\"14779\"\u003eZE-12CB22\u003c\/strong\u003e measures \u003cstrong data-start=\"14787\" data-end=\"14817\"\u003e28 1\/8 × 21 1\/4 × 9 1\/2 inches\u003c\/strong\u003e. It is relatively compact, which can facilitate installation in tight spaces. However, compact does not mean it can be installed just anywhere.\u003c\/p\u003e\n\u003cp data-start=\"14991\" data-end=\"15291\"\u003eThe outdoor unit must have enough clearance to breathe properly. It should be installed on a stable base, protected as much as possible against excessive snow accumulation, ice falls, roof water, and obstacles that could block air exchange.\u003c\/p\u003e\n\u003cp data-start=\"15293\" data-end=\"15693\"\u003eThe indicated outdoor sound pressure level is \u003cstrong data-start=\"15343\" data-end=\"15355\"\u003e53 dB(A)\u003c\/strong\u003e. This is a reasonable level, but location remains important, especially in dense areas of Montreal, Longueuil, or Laval, where neighbors can be close. On the South Shore and North Shore, we also see installations where wind, snow, or natural terrain drainage can affect winter performance.\u003c\/p\u003e\n\u003cp data-start=\"15695\" data-end=\"15905\"\u003eA good installation must therefore take the cold season into account from the start. \u003cstrong data-start=\"15776\" data-end=\"15905\"\u003eA poorly positioned outdoor unit can lose efficiency, accumulate ice, or become harder to maintain.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"15907\" data-end=\"15955\"\u003e1\/4 - 3\/8 inch piping: an essential detail\u003c\/h2\u003e\n\u003cp data-start=\"15957\" data-end=\"16147\"\u003eThe \u003cstrong data-start=\"15967\" data-end=\"15980\"\u003eZE-12CB22\u003c\/strong\u003e model uses \u003cstrong data-start=\"16004\" data-end=\"16030\"\u003e1\/4 inch liquid piping\u003c\/strong\u003e and \u003cstrong data-start=\"16034\" data-end=\"16056\"\u003e3\/8 inch gas piping\u003c\/strong\u003e. This information is essential, especially when replacing an old heat pump.\u003c\/p\u003e\n\u003cp data-start=\"16149\" data-end=\"16533\"\u003eYou should never assume that old refrigerant lines are compatible. Incorrect pipe sizing can harm performance, reliability, and warranty. During a replacement, we check the diameter, line condition, total length, type of refrigerant previously used, accessibility, and the possibility of properly replacing the route.\u003c\/p\u003e\n\u003cp data-start=\"16535\" data-end=\"16832\"\u003eThe sheet indicates a piping length of \u003cstrong data-start=\"16582\" data-end=\"16599\"\u003e10 to 65 feet\u003c\/strong\u003e, a maximum elevation of \u003cstrong data-start=\"16631\" data-end=\"16643\"\u003e50 feet\u003c\/strong\u003e, and a precharge length of \u003cstrong data-start=\"16676\" data-end=\"16688\"\u003e25 feet\u003c\/strong\u003e. These limits must be respected. An installation that is too long, poorly calculated, or poorly prepared can affect the actual performance of the device.\u003c\/p\u003e\n\u003cp data-start=\"16834\" data-end=\"17051\"\u003eAt AirGreen, we prefer to recommend line replacements when it is the best technical option. This may sometimes add a bit of work, but it protects the client’s investment in the long term.\u003c\/p\u003e\n\u003ch2 data-start=\"17053\" data-end=\"17125\"\u003e208V \/ 230V electrical supply: to be verified before installation\u003c\/h2\u003e\n\u003cp data-start=\"17127\" data-end=\"17334\"\u003eThe \u003cstrong data-start=\"17130\" data-end=\"17143\"\u003eZE-12CB22\u003c\/strong\u003e operates at \u003cstrong data-start=\"17158\" data-end=\"17189\"\u003e208V \/ 230V, 60 Hz, single phase\u003c\/strong\u003e. The technical sheet indicates a \u003cstrong data-start=\"17221\" data-end=\"17266\"\u003enominal current of 5.2 A in cooling\u003c\/strong\u003e, \u003cstrong data-start=\"17268\" data-end=\"17290\"\u003e4.8 A in heating\u003c\/strong\u003e, a \u003cstrong data-start=\"17295\" data-end=\"17311\"\u003eMCA of 9.5 A\u003c\/strong\u003e, and a \u003cstrong data-start=\"17318\" data-end=\"17333\"\u003eMOP of 15 A\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"17336\" data-end=\"17608\"\u003eThese values are important for the electrician and the HVAC installer. Before confirming the installation, the electrical panel, available space, breaker type, wire gauge, wiring route, and installation compliance must be checked.\u003c\/p\u003e\n\u003cp data-start=\"17610\" data-end=\"17880\"\u003eIn some older homes, especially in Montreal or Longueuil, the panel may already be fully loaded. In other cases, panel access is easy and the electrical installation poses no particular problems. Each project must be evaluated on site.\u003c\/p\u003e\n\u003cp data-start=\"17882\" data-end=\"18102\"\u003e\u003cstrong data-start=\"17882\" data-end=\"17950\"\u003eA high-performance device must always be properly powered.\u003c\/strong\u003e Poor electrical supply can cause operational issues, protection trips, or non-compliant installation.\u003c\/p\u003e\n\u003ch2 data-start=\"18104\" data-end=\"18139\"\u003ePractical daily functions\u003c\/h2\u003e\n\u003cp data-start=\"18141\" data-end=\"18244\"\u003eThe brochure mentions several features that make using the \u003cstrong data-start=\"18215\" data-end=\"18228\"\u003eZE-12CB22\u003c\/strong\u003e more enjoyable:\u003c\/p\u003e\n\u003cp data-start=\"18246\" data-end=\"18598\"\u003e• \u003cstrong data-start=\"18248\" data-end=\"18277\"\u003eLED wireless remote control\u003c\/strong\u003e;\u003cbr data-start=\"18278\" data-end=\"18281\"\u003e• \u003cstrong data-start=\"18283\" data-end=\"18302\"\u003eLED dimmer\u003c\/strong\u003e;\u003cbr data-start=\"18303\" data-end=\"18306\"\u003e• \u003cstrong data-start=\"18308\" data-end=\"18348\"\u003e5 indoor fan speeds\u003c\/strong\u003e;\u003cbr data-start=\"18349\" data-end=\"18352\"\u003e• \u003cstrong data-start=\"18354\" data-end=\"18372\"\u003eTurbo function\u003c\/strong\u003e;\u003cbr data-start=\"18373\" data-end=\"18376\"\u003e• \u003cstrong data-start=\"18378\" data-end=\"18403\"\u003eautomatic defrost\u003c\/strong\u003e;\u003cbr data-start=\"18404\" data-end=\"18407\"\u003e• \u003cstrong data-start=\"18409\" data-end=\"18434\"\u003eautomatic cleaning\u003c\/strong\u003e;\u003cbr data-start=\"18435\" data-end=\"18438\"\u003e• \u003cstrong data-start=\"18440\" data-end=\"18476\"\u003ediffuser position memory\u003c\/strong\u003e;\u003cbr data-start=\"18477\" data-end=\"18480\"\u003e• \u003cstrong data-start=\"18482\" data-end=\"18512\"\u003e8 °C automatic heating\u003c\/strong\u003e;\u003cbr data-start=\"18513\" data-end=\"18516\"\u003e• \u003cstrong data-start=\"18518\" data-end=\"18546\"\u003ereversible drain pipe\u003c\/strong\u003e;\u003cbr data-start=\"18547\" data-end=\"18550\"\u003e• \u003cstrong data-start=\"18552\" data-end=\"18597\"\u003eheated chassis for the outdoor base\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"18600\" data-end=\"19026\"\u003eThe \u003cstrong data-start=\"18603\" data-end=\"18621\"\u003eTurbo function\u003c\/strong\u003e can help reach the desired temperature faster. The \u003cstrong data-start=\"18690\" data-end=\"18715\"\u003eautomatic defrost\u003c\/strong\u003e is essential for winter operation. The \u003cstrong data-start=\"18766\" data-end=\"18791\"\u003eautomatic cleaning\u003c\/strong\u003e helps keep the indoor unit cleaner, although it does not replace regular maintenance. The \u003cstrong data-start=\"18897\" data-end=\"18927\"\u003e8 °C automatic heating\u003c\/strong\u003e can be useful in some rarely used spaces where you want to avoid too low a temperature.\u003c\/p\u003e\n\u003cp data-start=\"19028\" data-end=\"19318\"\u003eThe \u003cstrong data-start=\"19031\" data-end=\"19059\"\u003ereversible drain pipe\u003c\/strong\u003e and the \u003cstrong data-start=\"19066\" data-end=\"19088\"\u003etwo-sided drain\u003c\/strong\u003e also facilitate installation in different configurations. This type of detail may seem minor, but on a real job site, it can make a big difference in achieving a clean, discreet, and durable installation.\u003c\/p\u003e\n\u003ch2 data-start=\"19320\" data-end=\"19382\"\u003eHVAC Maintenance: preserving performance year after year\u003c\/h2\u003e\n\u003cp data-start=\"19384\" data-end=\"19592\"\u003eA well-installed wall-mounted heat pump must also be well maintained. To preserve performance, airflow, noise level, and operational quality, we recommend regular maintenance.\u003c\/p\u003e\n\u003cp data-start=\"19594\" data-end=\"19978\"\u003eThe owner should frequently clean the filters, monitor for unusual noises, check that the indoor unit is blowing properly, and ensure the outdoor unit remains clear. In winter, snow, ice, or debris must not block the device. In summer, leaves, dust, and outdoor residues can also affect performance.\u003c\/p\u003e\n\u003cp data-start=\"19980\" data-end=\"20280\"\u003eProfessional maintenance may be necessary when the device loses performance, emits an odor, leaks, makes more noise than before, or seems to run longer than usual. \u003cstrong data-start=\"20174\" data-end=\"20280\"\u003eProper maintenance extends the system’s lifespan and helps maintain more stable consumption.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"20282\" data-end=\"20525\"\u003eEven if the brochure mentions \u003cstrong data-start=\"20315\" data-end=\"20340\"\u003eautomatic cleaning\u003c\/strong\u003e, this function does not replace a thorough cleaning when the unit is dirty. It helps daily, but it should not be seen as a permanent solution without maintenance.\u003c\/p\u003e\n\u003ch2 data-start=\"20527\" data-end=\"20589\"\u003eMistakes to avoid before buying a 12,000 BTU heat pump\u003c\/h2\u003e\n\u003cp data-start=\"20591\" data-end=\"20753\"\u003eIn our experience, the most common mistakes do not always come from the brand choice. They often come from a poor project assessment.\u003c\/p\u003e\n\u003cp data-start=\"20755\" data-end=\"20783\"\u003eHere are the mistakes to avoid:\u003c\/p\u003e\n\u003cp data-start=\"20785\" data-end=\"21429\"\u003e• \u003cstrong data-start=\"20787\" data-end=\"20848\"\u003echoosing a 12,000 BTU unit without analyzing the actual area\u003c\/strong\u003e;\u003cbr data-start=\"20849\" data-end=\"20852\"\u003e• \u003cstrong data-start=\"20854\" data-end=\"20904\"\u003eneglecting insulation and sun exposure\u003c\/strong\u003e;\u003cbr data-start=\"20905\" data-end=\"20908\"\u003e• \u003cstrong data-start=\"20910\" data-end=\"20983\"\u003einstalling the indoor unit in a convenient but ineffective location\u003c\/strong\u003e;\u003cbr data-start=\"20984\" data-end=\"20987\"\u003e• \u003cstrong data-start=\"20989\" data-end=\"21038\"\u003eforgetting to check the electrical supply\u003c\/strong\u003e;\u003cbr data-start=\"21039\" data-end=\"21042\"\u003e• \u003cstrong data-start=\"21044\" data-end=\"21112\"\u003eassuming that old refrigerant lines are compatible\u003c\/strong\u003e;\u003cbr data-start=\"21113\" data-end=\"21116\"\u003e• \u003cstrong data-start=\"21118\" data-end=\"21183\"\u003eplacing the outdoor unit too close to a wall or fence\u003c\/strong\u003e;\u003cbr data-start=\"21184\" data-end=\"21187\"\u003e• \u003cstrong data-start=\"21189\" data-end=\"21229\"\u003eneglecting the impact of outdoor noise\u003c\/strong\u003e;\u003cbr data-start=\"21230\" data-end=\"21233\"\u003e• \u003cstrong data-start=\"21235\" data-end=\"21264\"\u003eignoring future maintenance\u003c\/strong\u003e;\u003cbr data-start=\"21265\" data-end=\"21268\"\u003e• \u003cstrong data-start=\"21270\" data-end=\"21343\"\u003emisunderstanding the actual low-temperature heating capacities\u003c\/strong\u003e;\u003cbr data-start=\"21344\" data-end=\"21347\"\u003e• \u003cstrong data-start=\"21349\" data-end=\"21428\"\u003ebuying solely based on price without checking installation quality\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"21431\" data-end=\"21660\"\u003eAt AirGreen, our role is to prevent these mistakes before the work begins. We want the client to understand why a model is recommended, how it will be installed, and what it can actually offer in their building.\u003c\/p\u003e\n\u003ch2 data-start=\"21662\" data-end=\"21725\"\u003eWhy choose AirGreen to install the Zephyr ZE-12CB22\u003c\/h2\u003e\n\u003cp data-start=\"21727\" data-end=\"21984\"\u003eAirGreen is a company specializing in \u003cstrong data-start=\"21770\" data-end=\"21778\"\u003eHVAC\u003c\/strong\u003e, active in Montreal, Laval, Longueuil, on the South Shore and the North Shore. We install, replace, maintain, and repair wall-mounted, central, and multi-zone heat pumps in a wide variety of settings.\u003c\/p\u003e\n\u003cp data-start=\"21986\" data-end=\"22231\"\u003eFor a model like the \u003cstrong data-start=\"22010\" data-end=\"22039\"\u003eZephyr CB22 R32 ZE-12CB22\u003c\/strong\u003e, our approach is simple: we first verify if the unit truly meets the need. Then, we plan the installation so the result is clean, efficient, and durable.\u003c\/p\u003e\n\u003cp data-start=\"22233\" data-end=\"22283\"\u003eBy choosing AirGreen, customers benefit from:\u003c\/p\u003e\n\u003cp data-start=\"22285\" data-end=\"22778\"\u003e• \u003cstrong data-start=\"22287\" data-end=\"22332\"\u003ea clear evaluation before work begins\u003c\/strong\u003e;\u003cbr data-start=\"22333\" data-end=\"22336\"\u003e• \u003cstrong data-start=\"22338\" data-end=\"22386\"\u003ea recommendation tailored to their building\u003c\/strong\u003e;\u003cbr data-start=\"22387\" data-end=\"22390\"\u003e• \u003cstrong data-start=\"22392\" data-end=\"22449\"\u003ean installation compliant with HVAC best practices\u003c\/strong\u003e;\u003cbr data-start=\"22450\" data-end=\"22453\"\u003e• \u003cstrong data-start=\"22455\" data-end=\"22523\"\u003ea thorough check of electrical and piping systems\u003c\/strong\u003e;\u003cbr data-start=\"22524\" data-end=\"22527\"\u003e• \u003cstrong data-start=\"22529\" data-end=\"22584\"\u003ean honest explanation of winter performance\u003c\/strong\u003e;\u003cbr data-start=\"22585\" data-end=\"22588\"\u003e• \u003cstrong data-start=\"22590\" data-end=\"22628\"\u003ea structured after-sales service\u003c\/strong\u003e;\u003cbr data-start=\"22629\" data-end=\"22632\"\u003e• \u003cstrong data-start=\"22634\" data-end=\"22690\"\u003ea team familiar with the realities of Greater Montreal\u003c\/strong\u003e;\u003cbr data-start=\"22691\" data-end=\"22694\"\u003e• \u003cstrong data-start=\"22696\" data-end=\"22777\"\u003esupport to understand warranties, options, and maintenance\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"22780\" data-end=\"23250\"\u003eThe \u003cstrong data-start=\"22783\" data-end=\"22822\"\u003eZephyr ZE-12CB22 wall-mounted heat pump\u003c\/strong\u003e is an interesting option for homeowners seeking an efficient, compact comfort solution well suited to a specific area. With its \u003cstrong data-start=\"22985\" data-end=\"23004\"\u003eR32 refrigerant\u003c\/strong\u003e, \u003cstrong data-start=\"23010\" data-end=\"23025\"\u003eSEER2 of 20\u003c\/strong\u003e, \u003cstrong data-start=\"23031\" data-end=\"23045\"\u003eHSPF2 of 9\u003c\/strong\u003e, heating operation down to \u003cstrong data-start=\"23087\" data-end=\"23097\"\u003e-25 °C\u003c\/strong\u003e, \u003cstrong data-start=\"23103\" data-end=\"23119\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"23125\" data-end=\"23136\"\u003e4D mode\u003c\/strong\u003e, and a \u003cstrong data-start=\"23155\" data-end=\"23172\"\u003e10-year parts warranty\u003c\/strong\u003e, it can meet many residential and light commercial needs.\u003c\/p\u003e\n\u003cp data-start=\"23252\" data-end=\"23484\"\u003eHowever, it requires careful installation. The right location, proper piping, correct electrical supply, adherence to clearances, and full startup are essential to achieve a reliable result.\u003c\/p\u003e\n\u003cp data-start=\"23486\" data-end=\"23817\"\u003eTo get a clear quote, compare the \u003cstrong data-start=\"23534\" data-end=\"23547\"\u003eZE-12CB22\u003c\/strong\u003e with other Zephyr models, or schedule an installation in Montreal, Laval, Longueuil, on the South Shore or the North Shore, contact AirGreen. Our team will help you choose the HVAC solution best suited to your space, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665925620004,"sku":"ZE-12CB22I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRCB22R32GRANDMONTREAL_c7c2d7ee-15cc-42a8-99fc-a7d0666cbde9.png?v=1783695947"},{"product_id":"thermopompe-murale-zephyr-cb22-r32-18000-btu-montreal-laval-rive-sud","title":"ZEPHYR CB22 R32 Wall Heat Pump | 18000 BTU | Montreal, Laval, South Shore","description":"\u003ch1 data-start=\"0\" data-end=\"118\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2\" data-end=\"118\"\u003eZephyr ZE-18CB22 Wall-Mounted Heat Pump — 18,000 BTU, R32, winter comfort down to -25 °C, and Energy Star efficiency\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"120\" data-end=\"593\"\u003eThe \u003cstrong data-start=\"123\" data-end=\"162\"\u003eZephyr ZE-18CB22 Wall-Mounted Heat Pump\u003c\/strong\u003e is an HVAC solution designed for homeowners seeking a reliable, efficient wall unit well suited to Quebec’s climate conditions. With a capacity of \u003cstrong data-start=\"341\" data-end=\"372\"\u003e18,000 BTU for cooling\u003c\/strong\u003e and \u003cstrong data-start=\"379\" data-end=\"415\"\u003e18,000 BTU for heating at 8.3 °C\u003c\/strong\u003e, this model targets spaces that require more than a small standard wall unit, without necessarily moving to a very high-capacity machine like a 24,000 BTU.\u003c\/p\u003e\n\u003cp data-start=\"595\" data-end=\"1128\"\u003eAt AirGreen, we recommend this type of wall-mounted heat pump when the customer wants to cool and heat a large living area, an open living room, a spacious condo, an office, a finished basement, or a residential area where temperature stability is important. The \u003cstrong data-start=\"883\" data-end=\"903\"\u003eZephyr ZE-18CB22\u003c\/strong\u003e positions itself as a balanced device: powerful enough to provide a good comfort reserve, yet still suitable for many residential configurations in Montreal, Laval, Longueuil, on the South Shore, and the North Shore.\u003c\/p\u003e\n\u003cp data-start=\"1130\" data-end=\"1799\"\u003eThis model is part of the \u003cstrong data-start=\"1164\" data-end=\"1183\"\u003eZephyr CB22 R32\u003c\/strong\u003e series, a range of wall-mounted heat pumps designed to offer \u003cstrong data-start=\"1241\" data-end=\"1272\"\u003eaffordable winter comfort\u003c\/strong\u003e, with heating operation down to \u003cstrong data-start=\"1318\" data-end=\"1328\"\u003e-25 °C\u003c\/strong\u003e and air conditioning mode down to \u003cstrong data-start=\"1362\" data-end=\"1372\"\u003e-15 °C\u003c\/strong\u003e. The brochure also highlights several practical features such as \u003cstrong data-start=\"1448\" data-end=\"1461\"\u003enight mode\u003c\/strong\u003e, \u003cstrong data-start=\"1466\" data-end=\"1482\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"1487\" data-end=\"1501\"\u003eiFeel mode\u003c\/strong\u003e, \u003cstrong data-start=\"1506\" data-end=\"1526\"\u003equick start\u003c\/strong\u003e, \u003cstrong data-start=\"1531\" data-end=\"1552\"\u003ebase heating\u003c\/strong\u003e, \u003cstrong data-start=\"1557\" data-end=\"1585\"\u003ecompressor heating\u003c\/strong\u003e, \u003cstrong data-start=\"1590\" data-end=\"1632\"\u003eauto-adaptive voltage technology\u003c\/strong\u003e, \u003cstrong data-start=\"1637\" data-end=\"1659\"\u003etwo-sided drain\u003c\/strong\u003e, \u003cstrong data-start=\"1664\" data-end=\"1682\"\u003e24-hour timer\u003c\/strong\u003e, \u003cstrong data-start=\"1687\" data-end=\"1698\"\u003e4D mode\u003c\/strong\u003e, \u003cstrong data-start=\"1703\" data-end=\"1728\"\u003eautomatic cleaning\u003c\/strong\u003e, and \u003cstrong data-start=\"1735\" data-end=\"1760\"\u003eautomatic defrosting\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-start=\"1801\" data-end=\"1884\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1804\" data-end=\"1884\"\u003eAn 18,000 BTU wall-mounted heat pump designed for adequately sized spaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1886\" data-end=\"2281\"\u003eThe \u003cstrong data-start=\"1889\" data-end=\"1909\"\u003eZephyr ZE-18CB22\u003c\/strong\u003e offers a cooling capacity of \u003cstrong data-start=\"1951\" data-end=\"1967\"\u003e18,000 BTU\/h\u003c\/strong\u003e at 35 °C. This power allows it to handle spaces larger than a simple bedroom or small office. It can be suitable for an open area, a partially open ground floor, a living room with dining area, a larger condo, or a living zone where heat accumulates quickly in summer.\u003c\/p\u003e\n\u003cp data-start=\"2283\" data-end=\"2670\"\u003eHowever, at AirGreen, we always remind that a heat pump should never be chosen solely based on the number of BTUs. An \u003cstrong data-start=\"2429\" data-end=\"2443\"\u003e18,000 BTU\u003c\/strong\u003e unit can deliver excellent results in a well-configured space, but it can also be poorly suited if the room is too closed off, if air circulation is poor, or if the indoor unit’s location does not allow good distribution.\u003c\/p\u003e\n\u003cp data-start=\"2672\" data-end=\"3095\"\u003eBefore confirming the installation of a wall-mounted heat pump like the \u003cstrong data-start=\"2740\" data-end=\"2753\"\u003eZE-18CB22\u003c\/strong\u003e, we assess several factors: \u003cstrong data-start=\"2790\" data-end=\"3094\"\u003ethe actual area to be treated, insulation, ceiling height, window orientation, solar load, openings between rooms, positioning of the indoor unit, location of the outdoor unit, piping route, drainage, and available electrical capacity\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3097\" data-end=\"3411\"\u003eA device that performs well on paper can deliver average results if it is poorly sized or installed. Conversely, a well-selected, well-positioned, and well-configured heat pump can transform the comfort of a space that was previously too hot in summer, too cold in winter, or difficult to balance.\u003c\/p\u003e\n\u003ch2 data-start=\"3413\" data-end=\"3486\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3416\" data-end=\"3486\"\u003eKey technical features of the Zephyr ZE-18CB22\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3488\" data-end=\"3568\"\u003eFor this \u003cstrong data-start=\"3503\" data-end=\"3517\"\u003e18,000 BTU\u003c\/strong\u003e model, the main information is as follows:\u003c\/p\u003e\n\u003cp data-start=\"3570\" data-end=\"5415\"\u003e• \u003cstrong data-start=\"3572\" data-end=\"3591\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"3591\" data-end=\"3594\"\u003e• \u003cstrong data-start=\"3596\" data-end=\"3612\"\u003eSeries: CB22\u003c\/strong\u003e\u003cbr data-start=\"3612\" data-end=\"3615\"\u003e• \u003cstrong data-start=\"3617\" data-end=\"3639\"\u003eModel: ZE-18CB22\u003c\/strong\u003e\u003cbr data-start=\"3639\" data-end=\"3642\"\u003e• \u003cstrong data-start=\"3644\" data-end=\"3673\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"3673\" data-end=\"3676\"\u003e• \u003cstrong data-start=\"3678\" data-end=\"3699\"\u003eRefrigerant: R32\u003c\/strong\u003e\u003cbr data-start=\"3699\" data-end=\"3702\"\u003e• \u003cstrong data-start=\"3704\" data-end=\"3758\"\u003eCooling capacity at 35 °C: 18,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3758\" data-end=\"3761\"\u003e• \u003cstrong data-start=\"3763\" data-end=\"3812\"\u003eHeating capacity at 8.3 °C: 18,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3812\" data-end=\"3815\"\u003e• \u003cstrong data-start=\"3817\" data-end=\"3831\"\u003eSEER2: 20\u003c\/strong\u003e\u003cbr data-start=\"3831\" data-end=\"3834\"\u003e• \u003cstrong data-start=\"3836\" data-end=\"3851\"\u003eHSPF2: 9.8\u003c\/strong\u003e\u003cbr data-start=\"3851\" data-end=\"3854\"\u003e• \u003cstrong data-start=\"3856\" data-end=\"3878\"\u003eEER2: 11.95 BTU\/W\u003c\/strong\u003e\u003cbr data-start=\"3878\" data-end=\"3881\"\u003e• \u003cstrong data-start=\"3883\" data-end=\"3918\"\u003eHeating COP at 8.3 °C: 3.9\u003c\/strong\u003e\u003cbr data-start=\"3918\" data-end=\"3921\"\u003e• \u003cstrong data-start=\"3923\" data-end=\"3957\"\u003eHeating COP2: 13.3 BTU\/W\u003c\/strong\u003e\u003cbr data-start=\"3957\" data-end=\"3960\"\u003e• \u003cstrong data-start=\"3962\" data-end=\"4021\"\u003eNominal heating capacity at -8.3 °C: 14,800 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4021\" data-end=\"4024\"\u003e• \u003cstrong data-start=\"4026\" data-end=\"4084\"\u003eMaximum heating capacity at -15 °C: 13,400 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4084\" data-end=\"4087\"\u003e• \u003cstrong data-start=\"4089\" data-end=\"4111\"\u003eCOP at -15 °C: 2.4\u003c\/strong\u003e\u003cbr data-start=\"4111\" data-end=\"4114\"\u003e• \u003cstrong data-start=\"4116\" data-end=\"4174\"\u003eMaximum heating capacity at -20 °C: 10,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4174\" data-end=\"4177\"\u003e• \u003cstrong data-start=\"4179\" data-end=\"4205\"\u003eEnergy Star V6.1: yes\u003c\/strong\u003e\u003cbr data-start=\"4205\" data-end=\"4208\"\u003e• \u003cstrong data-start=\"4210\" data-end=\"4241\"\u003eAirflow: 466 to 647 CFM\u003c\/strong\u003e\u003cbr data-start=\"4241\" data-end=\"4244\"\u003e• \u003cstrong data-start=\"4246\" data-end=\"4282\"\u003eRefrigerant charge: 45.86 oz\u003c\/strong\u003e\u003cbr data-start=\"4282\" data-end=\"4285\"\u003e• \u003cstrong data-start=\"4287\" data-end=\"4352\"\u003eIndoor sound pressure: 49 \/ 46 \/ 39 \/ 37 \/ 33 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"4352\" data-end=\"4355\"\u003e• \u003cstrong data-start=\"4357\" data-end=\"4402\"\u003eOutdoor sound pressure: 56 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"4402\" data-end=\"4405\"\u003e• \u003cstrong data-start=\"4407\" data-end=\"4446\"\u003eVoltage: 208\/230 V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"4446\" data-end=\"4449\"\u003e• \u003cstrong data-start=\"4451\" data-end=\"4495\"\u003eNominal cooling current: 6.4 A\u003c\/strong\u003e\u003cbr data-start=\"4495\" data-end=\"4498\"\u003e• \u003cstrong data-start=\"4500\" data-end=\"4540\"\u003eNominal heating current: 8.1 A\u003c\/strong\u003e\u003cbr data-start=\"4540\" data-end=\"4543\"\u003e• \u003cstrong data-start=\"4545\" data-end=\"4561\"\u003eMCA: 14.5 A\u003c\/strong\u003e\u003cbr data-start=\"4561\" data-end=\"4564\"\u003e• \u003cstrong data-start=\"4566\" data-end=\"4580\"\u003eMOP: 20 A\u003c\/strong\u003e\u003cbr data-start=\"4580\" data-end=\"4583\"\u003e• \u003cstrong data-start=\"4585\" data-end=\"4649\"\u003eCommunication wire required: 4\/14 copper multi-strand 600 V\u003c\/strong\u003e\u003cbr data-start=\"4649\" data-end=\"4652\"\u003e• \u003cstrong data-start=\"4654\" data-end=\"4687\"\u003eCompressor type: rotary\u003c\/strong\u003e\u003cbr data-start=\"4687\" data-end=\"4690\"\u003e• \u003cstrong data-start=\"4692\" data-end=\"4727\"\u003eCompressor manufacturer: GMCC\u003c\/strong\u003e\u003cbr data-start=\"4727\" data-end=\"4730\"\u003e• \u003cstrong data-start=\"4732\" data-end=\"4775\"\u003eExpansion device: capillary tube\u003c\/strong\u003e\u003cbr data-start=\"4775\" data-end=\"4778\"\u003e• \u003cstrong data-start=\"4780\" data-end=\"4809\"\u003eIndoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"4809\" data-end=\"4812\"\u003e• \u003cstrong data-start=\"4814\" data-end=\"4843\"\u003eOutdoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"4843\" data-end=\"4846\"\u003e• \u003cstrong data-start=\"4848\" data-end=\"4874\"\u003eLiquid pipe: 1\/4 in\u003c\/strong\u003e\u003cbr data-start=\"4874\" data-end=\"4877\"\u003e• \u003cstrong data-start=\"4879\" data-end=\"4901\"\u003eGas pipe: 1\/2 in\u003c\/strong\u003e\u003cbr data-start=\"4901\" data-end=\"4904\"\u003e• \u003cstrong data-start=\"4906\" data-end=\"4956\"\u003eMinimum-maximum piping length: 10 to 98 feet\u003c\/strong\u003e\u003cbr data-start=\"4956\" data-end=\"4959\"\u003e• \u003cstrong data-start=\"4961\" data-end=\"4998\"\u003eMaximum elevation difference: 50 feet\u003c\/strong\u003e\u003cbr data-start=\"4998\" data-end=\"5001\"\u003e• \u003cstrong data-start=\"5003\" data-end=\"5039\"\u003ePrecharge length: 25 feet\u003c\/strong\u003e\u003cbr data-start=\"5039\" data-end=\"5042\"\u003e• \u003cstrong data-start=\"5044\" data-end=\"5111\"\u003eIndoor unit dimensions: 42 1\/16 × 12 5\/8 × 9 1\/16 in\u003c\/strong\u003e\u003cbr data-start=\"5111\" data-end=\"5114\"\u003e• \u003cstrong data-start=\"5116\" data-end=\"5174\"\u003eOutdoor unit dimensions: 31 7\/8 × 23 × 11 in\u003c\/strong\u003e\u003cbr data-start=\"5174\" data-end=\"5177\"\u003e• \u003cstrong data-start=\"5179\" data-end=\"5240\"\u003eCooling operating range: -15 °C to 48 °C\u003c\/strong\u003e\u003cbr data-start=\"5240\" data-end=\"5243\"\u003e• \u003cstrong data-start=\"5245\" data-end=\"5302\"\u003eHeating operating range: -25 °C to 24 °C\u003c\/strong\u003e\u003cbr data-start=\"5302\" data-end=\"5305\"\u003e• \u003cstrong data-start=\"5307\" data-end=\"5343\"\u003eBasic warranty: 10 years parts\u003c\/strong\u003e\u003cbr data-start=\"5343\" data-end=\"5346\"\u003e• \u003cstrong data-start=\"5348\" data-end=\"5415\"\u003eLabor warranty: available depending on the distributor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5417\" data-end=\"5840\"\u003eThis data is essential because it directly influences the choice of device, installation feasibility, and the system’s actual performance. For example, an \u003cstrong data-start=\"5612\" data-end=\"5626\"\u003e18,000 BTU\u003c\/strong\u003e heat pump with a \u003cstrong data-start=\"5652\" data-end=\"5665\"\u003e208\/230 V\u003c\/strong\u003e power supply, a \u003cstrong data-start=\"5670\" data-end=\"5685\"\u003e20 A MOP\u003c\/strong\u003e, and a \u003cstrong data-start=\"5692\" data-end=\"5709\"\u003e14.5 A MCA\u003c\/strong\u003e must be electrically validated before installation. This is not the same type of project as a small 115 V wall unit.\u003c\/p\u003e\n\u003ch2 data-start=\"5842\" data-end=\"5908\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5845\" data-end=\"5908\"\u003eWhy R32 is relevant for this wall-mounted heat pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"5910\" data-end=\"6239\"\u003eThe \u003cstrong data-start=\"5913\" data-end=\"5933\"\u003eZephyr ZE-18CB22\u003c\/strong\u003e uses \u003cstrong data-start=\"5945\" data-end=\"5964\"\u003eR32 refrigerant\u003c\/strong\u003e, a gas widely used in new generations of wall-mounted heat pumps. For the customer, the refrigerant name may seem technical, but it is important because it is part of the overall device design and influences proper installation practices.\u003c\/p\u003e\n\u003cp data-start=\"6241\" data-end=\"6612\"\u003eThe \u003cstrong data-start=\"6244\" data-end=\"6251\"\u003eR32\u003c\/strong\u003e is paired with modern, efficient equipment well suited to current residential needs. That said, an R32 heat pump must be installed with precision. Connections must be clean, piping lengths must be respected, the leak test must be properly performed, and the vacuum pull must be done thoroughly.\u003c\/p\u003e\n\u003cp data-start=\"6614\" data-end=\"6937\"\u003eAt AirGreen, we emphasize this point: \u003cstrong data-start=\"6659\" data-end=\"6729\"\u003ea modern device does not tolerate a sloppy installation\u003c\/strong\u003e. Even a high-performance heat pump can lose efficiency, become noisy, or develop premature issues if the piping, electrical work, drainage, or clearances are not properly planned.\u003c\/p\u003e\n\u003ch2 data-start=\"6939\" data-end=\"7021\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6942\" data-end=\"7021\"\u003eBalanced energy efficiency for heating and cooling\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"7023\" data-end=\"7264\"\u003eThe technical sheet for the \u003cstrong data-start=\"7048\" data-end=\"7068\"\u003eZephyr ZE-18CB22\u003c\/strong\u003e indicates a \u003cstrong data-start=\"7080\" data-end=\"7095\"\u003eSEER2 of 20\u003c\/strong\u003e for cooling and an \u003cstrong data-start=\"7121\" data-end=\"7137\"\u003eHSPF2 of 9.8\u003c\/strong\u003e for heating. These two figures are important for evaluating the unit’s energy performance over a full season.\u003c\/p\u003e\n\u003cp data-start=\"7266\" data-end=\"7550\"\u003eThe \u003cstrong data-start=\"7269\" data-end=\"7278\"\u003eSEER2\u003c\/strong\u003e measures seasonal cooling efficiency. The higher it is, the more the unit is designed to cool efficiently using less energy. In the case of the ZE-18CB22, the \u003cstrong data-start=\"7465\" data-end=\"7480\"\u003eSEER2 of 20\u003c\/strong\u003e represents good performance for a wall-mounted unit of this capacity.\u003c\/p\u003e\n\u003cp data-start=\"7552\" data-end=\"7936\"\u003eThe \u003cstrong data-start=\"7555\" data-end=\"7571\"\u003eHSPF2 of 9.8\u003c\/strong\u003e provides an indication of heating efficiency. In Quebec, this figure is especially important because a heat pump is not used just a few weeks a year. It can contribute to comfort during fall, winter, and spring by reducing the use of traditional electric heating when conditions allow.\u003c\/p\u003e\n\u003cp data-start=\"7938\" data-end=\"8268\"\u003eThe \u003cstrong data-start=\"7941\" data-end=\"7964\"\u003eCOP of 3.9 at 8.3 °C\u003c\/strong\u003e means the unit can produce multiple units of heat for each unit of electricity consumed under favorable conditions. Even at \u003cstrong data-start=\"8112\" data-end=\"8122\"\u003e-15 °C\u003c\/strong\u003e, the sheet indicates a \u003cstrong data-start=\"8144\" data-end=\"8158\"\u003eCOP of 2.4\u003c\/strong\u003e, showing that the unit maintains good efficiency as the outdoor temperature drops.\u003c\/p\u003e\n\u003ch2 data-start=\"8270\" data-end=\"8335\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"8273\" data-end=\"8335\"\u003eHeating down to -25 °C: what this really means\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"8337\" data-end=\"8655\"\u003eThe Zephyr CB22 brochure states that this series can operate in heating mode down to \u003cstrong data-start=\"8423\" data-end=\"8433\"\u003e-25 °C\u003c\/strong\u003e. For homeowners in Montreal, Laval, Longueuil, the South Shore, and the North Shore, this is an important point, as Quebec winters require a unit capable of functioning well below mild temperatures.\u003c\/p\u003e\n\u003cp data-start=\"8657\" data-end=\"9005\"\u003eIt is important to understand that the heating capacity of a heat pump naturally decreases as the outdoor temperature drops. For the \u003cstrong data-start=\"8805\" data-end=\"8818\"\u003eZE-18CB22\u003c\/strong\u003e, the technical sheet indicates a nominal capacity of \u003cstrong data-start=\"8872\" data-end=\"8898\"\u003e14,800 BTU\/h at -8.3 °C\u003c\/strong\u003e, a maximum capacity of \u003cstrong data-start=\"8925\" data-end=\"8950\"\u003e13,400 BTU\/h at -15 °C\u003c\/strong\u003e, and a maximum capacity of \u003cstrong data-start=\"8979\" data-end=\"9004\"\u003e10,000 BTU\/h at -20 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"9007\" data-end=\"9391\"\u003eThese figures are very useful for evaluating real winter performance. In a well-insulated house, this capacity can cover a large part of the heating needs of the served area. In an older house, with many windows, exposed to wind, or with significant heat loss, supplementary heating may still be necessary on the coldest days.\u003c\/p\u003e\n\u003cp data-start=\"9393\" data-end=\"9730\"\u003eAt AirGreen, we prefer to explain this reality from the start. A high-performance wall-mounted heat pump can significantly reduce traditional heating consumption, but it must be intelligently integrated into the building. \u003cstrong data-start=\"9620\" data-end=\"9730\"\u003eThe right result always comes from the right choice of device, the right location, and proper installation.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"9732\" data-end=\"9826\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"9735\" data-end=\"9826\"\u003eIndoor comfort: 4D mode, automatic oscillation, and better air distribution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"9828\" data-end=\"10066\"\u003eThe \u003cstrong data-start=\"9831\" data-end=\"9851\"\u003eZephyr ZE-18CB22\u003c\/strong\u003e focuses on air distribution. The brochure presents \u003cstrong data-start=\"9919\" data-end=\"9930\"\u003e4D mode\u003c\/strong\u003e and \u003cstrong data-start=\"9936\" data-end=\"9963\"\u003eautomatic oscillation\u003c\/strong\u003e, two features designed to better distribute air in the room and reduce cold or hot spots.\u003c\/p\u003e\n\u003cp data-start=\"10068\" data-end=\"10454\"\u003eIn an open area, air distribution is a key factor. A heat pump may have good capacity, but if the air is blown in the wrong direction or blocked by a beam, wall, tall furniture, or interior partition, comfort can be uneven. The \u003cstrong data-start=\"10352\" data-end=\"10363\"\u003e4D mode\u003c\/strong\u003e helps improve diffusion, but it does not replace a proper location analysis.\u003c\/p\u003e\n\u003cp data-start=\"10456\" data-end=\"10876\"\u003eAt AirGreen, we pay special attention to the positioning of the indoor unit. We avoid placing the device so that it blows directly on occupants for long periods whenever possible. Instead, we look for a location that allows good air circulation in the main area while respecting the building’s aesthetics and the feasibility of piping installation.\u003c\/p\u003e\n\u003ch2 data-start=\"10878\" data-end=\"10960\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10881\" data-end=\"10960\"\u003eiFeel mode, silent mode, and night mode: more precise comfort every day\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"10962\" data-end=\"11312\"\u003eThe \u003cstrong data-start=\"10965\" data-end=\"10978\"\u003eZE-18CB22\u003c\/strong\u003e offers several comfort features that make daily use more enjoyable. The \u003cstrong data-start=\"11072\" data-end=\"11086\"\u003eiFeel mode\u003c\/strong\u003e allows adjustment based on the temperature sensed near the remote control, which can be useful when the temperature near the indoor unit is not exactly the same as in the occupied area.\u003c\/p\u003e\n\u003cp data-start=\"11314\" data-end=\"11716\"\u003eThe \u003cstrong data-start=\"11317\" data-end=\"11333\"\u003esilent mode\u003c\/strong\u003e is particularly useful for living rooms, bedrooms, offices, or workspaces. The indoor sound pressure of this model drops to \u003cstrong data-start=\"11488\" data-end=\"11516\"\u003e33 dB(A) in silent mode\u003c\/strong\u003e, allowing discreet operation when conditions are favorable. The noise level varies according to fan speed, with values indicated at \u003cstrong data-start=\"11683\" data-end=\"11715\"\u003e49 \/ 46 \/ 39 \/ 37 \/ 33 dB(A)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"11718\" data-end=\"12021\"\u003eThe \u003cstrong data-start=\"11721\" data-end=\"11734\"\u003enight mode\u003c\/strong\u003e helps maintain gentler comfort during sleeping hours. The \u003cstrong data-start=\"11807\" data-end=\"11825\"\u003e24-hour timer\u003c\/strong\u003e also allows programming the device according to occupants' habits, for example to reduce use when the house is empty or to prepare comfort before returning home.\u003c\/p\u003e\n\u003ch2 data-start=\"12023\" data-end=\"12117\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"12026\" data-end=\"12117\"\u003eVariable frequency technology: stability and reduction of temperature fluctuations\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"12119\" data-end=\"12389\"\u003eThe brochure explains that variable frequency technology allows the heat pump to adjust its power in real time. This approach is important because it avoids abrupt temperature changes and allows for more gradual use of the device.\u003c\/p\u003e\n\u003cp data-start=\"12391\" data-end=\"12791\"\u003eA traditional on-off system often works in more pronounced cycles: it starts, blows strongly, reaches the temperature, then stops. A variable technology heat pump can instead modulate its power to maintain more stable comfort. This helps reduce hot-cold sensations, improves overall comfort, and can contribute to better energy efficiency.\u003c\/p\u003e\n\u003cp data-start=\"12793\" data-end=\"13153\"\u003eFor a customer, this difference is mostly felt daily. The temperature seems more consistent, the device operates more smoothly, and the room becomes more comfortable to live in. In a house in Montreal or Longueuil with interior partitions, or in a condo in Laval with an open floor plan, this stability can make a real difference.\u003c\/p\u003e\n\u003ch2 data-start=\"13155\" data-end=\"13216\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"13158\" data-end=\"13216\"\u003eHVAC Installation: the details that make the difference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"13218\" data-end=\"13442\"\u003eInstalling a wall-mounted heat pump is not just about mounting the indoor unit on the wall. For a model like the \u003cstrong data-start=\"13333\" data-end=\"13353\"\u003eZephyr ZE-18CB22\u003c\/strong\u003e, several technical decisions directly affect performance and durability.\u003c\/p\u003e\n\u003cp data-start=\"13444\" data-end=\"13735\"\u003eThe indoor unit measures \u003cstrong data-start=\"13470\" data-end=\"13502\"\u003e42 1\/16 × 12 5\/8 × 9 1\/16 in\u003c\/strong\u003e. This dimension must be considered before installation, especially in spaces with limited clear heights, narrow walls, or when there are moldings, curtains, cabinets, beams, or sloped ceilings.\u003c\/p\u003e\n\u003cp data-start=\"13737\" data-end=\"14139\"\u003eThe outdoor unit measures \u003cstrong data-start=\"13763\" data-end=\"13786\"\u003e31 7\/8 × 23 × 11 inches\u003c\/strong\u003e. It must be installed in a stable, well-cleared location, accessible for maintenance, and protected as much as possible against excessive accumulations of snow, ice, or water from the roof. In Quebec, this detail is very important. A poorly placed outdoor unit can operate more difficultly in winter and require more maintenance.\u003c\/p\u003e\n\u003cp data-start=\"14141\" data-end=\"14439\"\u003eAt AirGreen, we always analyze the route between the indoor and outdoor units. We look for a clean, efficient, and durable piping path, taking into account exterior aesthetics, drain slope, building structure, and future service access.\u003c\/p\u003e\n\u003ch2 data-start=\"14441\" data-end=\"14517\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"14444\" data-end=\"14517\"\u003e1\/4 - 1\/2 inch Piping: A Point to Check Before Any Replacement\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"14519\" data-end=\"14693\"\u003eThe \u003cstrong data-start=\"14522\" data-end=\"14535\"\u003eZE-18CB22\u003c\/strong\u003e uses \u003cstrong data-start=\"14562\" data-end=\"14588\"\u003e1\/4 inch liquid\u003c\/strong\u003e and \u003cstrong data-start=\"14592\" data-end=\"14614\"\u003e1\/2 inch gas\u003c\/strong\u003e piping. This information is crucial when replacing an old heat pump.\u003c\/p\u003e\n\u003cp data-start=\"14695\" data-end=\"15060\"\u003eMany customers want to reuse existing lines to reduce work. Sometimes, this is possible. But it should never be assumed without verification. The diameter of the lines, their condition, cleanliness, length, the old refrigerant used, accessibility, and the possibility of properly connecting them to the new system must be confirmed.\u003c\/p\u003e\n\u003cp data-start=\"15062\" data-end=\"15419\"\u003eThe datasheet indicates a piping length of \u003cstrong data-start=\"15109\" data-end=\"15126\"\u003e10 to 98 feet\u003c\/strong\u003e, a maximum elevation of \u003cstrong data-start=\"15158\" data-end=\"15170\"\u003e50 feet\u003c\/strong\u003e, and a precharge length of \u003cstrong data-start=\"15203\" data-end=\"15215\"\u003e25 feet\u003c\/strong\u003e. These limits must be respected to ensure proper operation of the unit. Piping that is too long, poorly insulated, improperly installed, or incompatible can impair performance and reliability.\u003c\/p\u003e\n\u003ch2 data-start=\"15421\" data-end=\"15490\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"15424\" data-end=\"15490\"\u003e208\/230 V Power Supply: An Essential Validation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"15492\" data-end=\"15695\"\u003eThe \u003cstrong data-start=\"15495\" data-end=\"15515\"\u003eZephyr ZE-18CB22\u003c\/strong\u003e operates on \u003cstrong data-start=\"15530\" data-end=\"15559\"\u003e208\/230 V, 60 Hz, 1 phase\u003c\/strong\u003e. It requires a \u003cstrong data-start=\"15577\" data-end=\"15594\"\u003eMCA of 14.5 A\u003c\/strong\u003e and a maximum protection of \u003cstrong data-start=\"15622\" data-end=\"15637\"\u003eMOP of 20 A\u003c\/strong\u003e. These specifications must be verified before installation.\u003c\/p\u003e\n\u003cp data-start=\"15697\" data-end=\"16045\"\u003eIn many older homes in Montreal, Laval, or Longueuil, the electrical panel may already be fully loaded. It is therefore necessary to confirm that there is enough space and capacity to add the required circuit. The required communication wire is a \u003cstrong data-start=\"15951\" data-end=\"15986\"\u003e4\/14 copper multi-strand 600 V\u003c\/strong\u003e, an important detail for installation compliance.\u003c\/p\u003e\n\u003cp data-start=\"16047\" data-end=\"16332\"\u003eA poorly assessed electrical installation can cause delays, extra costs, or unexpected adjustments. At AirGreen, we prefer to validate these elements from the start to offer a more realistic quote and avoid unpleasant surprises during the work.\u003c\/p\u003e\n\u003ch2 data-start=\"16334\" data-end=\"16401\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"16337\" data-end=\"16401\"\u003eNoise level: a discreet device, but needs proper positioning\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"16403\" data-end=\"16701\"\u003eThe technical sheet indicates an outdoor sound pressure of \u003cstrong data-start=\"16468\" data-end=\"16480\"\u003e56 dB(A)\u003c\/strong\u003e for the \u003cstrong data-start=\"16489\" data-end=\"16502\"\u003eZE-18CB22\u003c\/strong\u003e. This noise level is reasonable for a unit of this capacity, but the outdoor location remains important, especially in denser neighborhoods or buildings where neighbors are close.\u003c\/p\u003e\n\u003cp data-start=\"16703\" data-end=\"16959\"\u003eIndoors, the noise level varies according to the ventilation speed, with a range of \u003cstrong data-start=\"16792\" data-end=\"16809\"\u003e49 to 33 dB(A)\u003c\/strong\u003e. In silent mode, the device can operate more discreetly, which is appreciated in bedrooms, offices, or relaxation areas.\u003c\/p\u003e\n\u003cp data-start=\"16961\" data-end=\"17376\"\u003eHowever, even a relatively quiet device can become disturbing if poorly placed. The indoor unit should not be installed too close to a bed, a workstation, or a place where occupants sit for long periods. The outdoor unit should also be placed considering neighbors, windows, terraces, balconies, and walls that can reflect sound.\u003c\/p\u003e\n\u003ch2 data-start=\"17378\" data-end=\"17449\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"17381\" data-end=\"17449\"\u003ePractical features for easier daily use\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"17451\" data-end=\"17859\"\u003eThe \u003cstrong data-start=\"17454\" data-end=\"17474\"\u003eZephyr ZE-18CB22\u003c\/strong\u003e includes several features that enhance the user experience. The \u003cstrong data-start=\"17548\" data-end=\"17568\"\u003equick start\u003c\/strong\u003e allows you to reach the desired comfort faster. The \u003cstrong data-start=\"17628\" data-end=\"17646\"\u003eTurbo function\u003c\/strong\u003e is useful when the room needs to be cooled or heated quickly. The \u003cstrong data-start=\"17721\" data-end=\"17753\"\u003eautomatic 8 °C heating\u003c\/strong\u003e can help maintain a minimum temperature in certain spaces when occupants are absent.\u003c\/p\u003e\n\u003cp data-start=\"17861\" data-end=\"18215\"\u003eThe \u003cstrong data-start=\"17864\" data-end=\"17889\"\u003eautomatic cleaning\u003c\/strong\u003e and \u003cstrong data-start=\"17896\" data-end=\"17921\"\u003eautomatic defrosting\u003c\/strong\u003e help maintain the device’s proper operation. The \u003cstrong data-start=\"17986\" data-end=\"18022\"\u003ediffuser position memory\u003c\/strong\u003e makes it easier to restore a comfortable airflow setting. The \u003cstrong data-start=\"18106\" data-end=\"18134\"\u003ereversible drain pipe\u003c\/strong\u003e and \u003cstrong data-start=\"18141\" data-end=\"18163\"\u003etwo-sided drain\u003c\/strong\u003e provide more flexibility during installation.\u003c\/p\u003e\n\u003cp data-start=\"18217\" data-end=\"18612\"\u003eThe brochure also mentions a \u003cstrong data-start=\"18249\" data-end=\"18278\"\u003efireproof electrical box\u003c\/strong\u003e, \u003cstrong data-start=\"18284\" data-end=\"18326\"\u003eauto-adaptive voltage technology\u003c\/strong\u003e, a \u003cstrong data-start=\"18331\" data-end=\"18359\"\u003ecompressor heater\u003c\/strong\u003e, and a \u003cstrong data-start=\"18366\" data-end=\"18411\"\u003eheated chassis for the outdoor base\u003c\/strong\u003e. These features are especially relevant in a Quebec context, where temperature fluctuations, humidity, frost, and winter conditions can challenge equipment.\u003c\/p\u003e\n\u003ch2 data-start=\"18614\" data-end=\"18680\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"18617\" data-end=\"18680\"\u003eHVAC Maintenance: maintaining performance year after year\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"18682\" data-end=\"19010\"\u003eA high-performance wall-mounted heat pump must be properly maintained to retain its efficiency. Even a well-designed model like the \u003cstrong data-start=\"18817\" data-end=\"18837\"\u003eZephyr ZE-18CB22\u003c\/strong\u003e can lose performance if the filters are dirty, the heat exchanger is clogged, the drain is blocked, or the outdoor unit is surrounded by leaves, snow, or debris.\u003c\/p\u003e\n\u003cp data-start=\"19012\" data-end=\"19041\"\u003eWe especially recommend:\u003c\/p\u003e\n\u003cp data-start=\"19043\" data-end=\"19539\"\u003e• \u003cstrong data-start=\"19045\" data-end=\"19105\"\u003eregularly clean the indoor unit filters\u003c\/strong\u003e;\u003cbr data-start=\"19106\" data-end=\"19109\"\u003e• \u003cstrong data-start=\"19111\" data-end=\"19174\"\u003echeck that the condensation drain flows properly\u003c\/strong\u003e;\u003cbr data-start=\"19175\" data-end=\"19178\"\u003e• \u003cstrong data-start=\"19180\" data-end=\"19233\"\u003ekeep the outdoor unit clear in all seasons\u003c\/strong\u003e;\u003cbr data-start=\"19234\" data-end=\"19237\"\u003e• \u003cstrong data-start=\"19239\" data-end=\"19308\"\u003eremove snow, leaves, and debris around the device\u003c\/strong\u003e;\u003cbr data-start=\"19309\" data-end=\"19312\"\u003e• \u003cstrong data-start=\"19314\" data-end=\"19380\"\u003ewatch for unusual noises or performance loss\u003c\/strong\u003e;\u003cbr data-start=\"19381\" data-end=\"19384\"\u003e• \u003cstrong data-start=\"19386\" data-end=\"19475\"\u003ehave the device inspected if heating or cooling becomes less effective\u003c\/strong\u003e;\u003cbr data-start=\"19476\" data-end=\"19479\"\u003e• \u003cstrong data-start=\"19481\" data-end=\"19538\"\u003eschedule professional maintenance when necessary\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"19541\" data-end=\"19701\"\u003eProper maintenance helps preserve comfort, reduce the risk of breakdowns, and assist the device in operating more efficiently for many years.\u003c\/p\u003e\n\u003ch2 data-start=\"19703\" data-end=\"19773\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"19706\" data-end=\"19773\"\u003eMistakes to avoid before buying an 18,000 BTU heat pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"19775\" data-end=\"19937\"\u003eIn our experience, the most common mistakes don’t always come from the brand choice. They often come from a poor project assessment.\u003c\/p\u003e\n\u003cp data-start=\"19939\" data-end=\"19988\"\u003eHere are the mistakes we regularly see:\u003c\/p\u003e\n\u003cp data-start=\"19990\" data-end=\"20686\"\u003e• \u003cstrong data-start=\"19992\" data-end=\"20083\"\u003echoosing an 18,000 BTU heat pump without analyzing the actual space layout\u003c\/strong\u003e;\u003cbr data-start=\"20084\" data-end=\"20087\"\u003e• \u003cstrong data-start=\"20089\" data-end=\"20200\"\u003einstalling the indoor unit in a location convenient for pipes but poor for air distribution\u003c\/strong\u003e;\u003cbr data-start=\"20201\" data-end=\"20204\"\u003e• \u003cstrong data-start=\"20206\" data-end=\"20272\"\u003eforgetting to check the electrical panel before installation\u003c\/strong\u003e;\u003cbr data-start=\"20273\" data-end=\"20276\"\u003e• \u003cstrong data-start=\"20278\" data-end=\"20346\"\u003eassuming old refrigerant lines are compatible\u003c\/strong\u003e;\u003cbr data-start=\"20347\" data-end=\"20350\"\u003e• \u003cstrong data-start=\"20352\" data-end=\"20413\"\u003eneglecting outdoor noise levels in a dense area\u003c\/strong\u003e;\u003cbr data-start=\"20414\" data-end=\"20417\"\u003e• \u003cstrong data-start=\"20419\" data-end=\"20497\"\u003eplacing the outdoor unit too close to a wall, fence, or neighbor\u003c\/strong\u003e;\u003cbr data-start=\"20498\" data-end=\"20501\"\u003e• \u003cstrong data-start=\"20503\" data-end=\"20553\"\u003eignoring snow, ice, and roof water\u003c\/strong\u003e;\u003cbr data-start=\"20554\" data-end=\"20557\"\u003e• \u003cstrong data-start=\"20559\" data-end=\"20600\"\u003eunderestimating the importance of drainage\u003c\/strong\u003e;\u003cbr data-start=\"20601\" data-end=\"20604\"\u003e• \u003cstrong data-start=\"20606\" data-end=\"20685\"\u003ebuying based only on price, without considering installation quality\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"20688\" data-end=\"20891\"\u003eAt AirGreen, our role is to clarify these points before the work begins. This helps avoid unpleasant surprises and ensures a more durable, cleaner, and better-adapted installation for the building.\u003c\/p\u003e\n\u003ch2 data-start=\"20893\" data-end=\"20960\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"20896\" data-end=\"20960\"\u003eWhy choose AirGreen to install the Zephyr ZE-18CB22\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"20962\" data-end=\"21231\"\u003eAirGreen is an HVAC company specializing in the installation, maintenance, and repair of wall, central, and multi-zone heat pumps in Greater Montreal. We regularly operate in \u003cstrong data-start=\"21152\" data-end=\"21230\"\u003eMontreal, Laval, Longueuil, on the South Shore, the North Shore, and in Montérégie\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"21233\" data-end=\"21513\"\u003eOur local knowledge allows us to better understand the realities of Quebec buildings: old houses, modern condos, multiplexes, finished basements, brick walls, open spaces, lower ceilings, neighborhood constraints, and sometimes limited electrical panels.\u003c\/p\u003e\n\u003cp data-start=\"21515\" data-end=\"21631\"\u003eBy choosing AirGreen for the installation of a \u003cstrong data-start=\"21565\" data-end=\"21604\"\u003eZephyr ZE-18CB22 Wall Heat Pump\u003c\/strong\u003e, customers benefit from:\u003c\/p\u003e\n\u003cp data-start=\"21633\" data-end=\"22104\"\u003e• \u003cstrong data-start=\"21635\" data-end=\"21680\"\u003ea clear assessment before the work\u003c\/strong\u003e;\u003cbr data-start=\"21681\" data-end=\"21684\"\u003e• \u003cstrong data-start=\"21686\" data-end=\"21736\"\u003ea selection of equipment suited to the building\u003c\/strong\u003e;\u003cbr data-start=\"21737\" data-end=\"21740\"\u003e• \u003cstrong data-start=\"21742\" data-end=\"21790\"\u003ea verification of the required capacity\u003c\/strong\u003e;\u003cbr data-start=\"21791\" data-end=\"21794\"\u003e• \u003cstrong data-start=\"21796\" data-end=\"21853\"\u003eanalysis of the indoor and outdoor location\u003c\/strong\u003e;\u003cbr data-start=\"21854\" data-end=\"21857\"\u003e• \u003cstrong data-start=\"21859\" data-end=\"21916\"\u003einstallation compliant with good HVAC practices\u003c\/strong\u003e;\u003cbr data-start=\"21917\" data-end=\"21920\"\u003e• \u003cstrong data-start=\"21922\" data-end=\"21977\"\u003ean honest explanation of winter performance\u003c\/strong\u003e;\u003cbr data-start=\"21978\" data-end=\"21981\"\u003e• \u003cstrong data-start=\"21983\" data-end=\"22059\"\u003esupport to understand the available warranties and options\u003c\/strong\u003e;\u003cbr data-start=\"22060\" data-end=\"22063\"\u003e• \u003cstrong data-start=\"22065\" data-end=\"22103\"\u003estructured after-sales service\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"22106\" data-end=\"22360\"\u003eWe know that a heat pump is a significant investment. Our goal is for the customer to understand what they are buying, why this model is recommended, how it will be installed, and how to use it to achieve the best possible performance.\u003c\/p\u003e\n\u003ch2 data-start=\"22362\" data-end=\"22433\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"22365\" data-end=\"22433\"\u003eA reliable HVAC solution for demanding residential projects\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"22435\" data-end=\"22757\"\u003eThe \u003cstrong data-start=\"22438\" data-end=\"22477\"\u003eZephyr ZE-18CB22 Wall Heat Pump\u003c\/strong\u003e is an interesting choice for homeowners who want an \u003cstrong data-start=\"22561\" data-end=\"22575\"\u003e18,000 BTU\u003c\/strong\u003e wall solution, operating on \u003cstrong data-start=\"22593\" data-end=\"22600\"\u003eR32\u003c\/strong\u003e, with good energy efficiency, an \u003cstrong data-start=\"22659\" data-end=\"22679\"\u003eEnergy Star V6.1\u003c\/strong\u003e certification, heating down to \u003cstrong data-start=\"22702\" data-end=\"22712\"\u003e-25 °C\u003c\/strong\u003e, and several integrated comfort features.\u003c\/p\u003e\n\u003cp data-start=\"22759\" data-end=\"23221\"\u003eIt stands out with its \u003cstrong data-start=\"22785\" data-end=\"22800\"\u003eSEER2 of 20\u003c\/strong\u003e, its \u003cstrong data-start=\"22806\" data-end=\"22822\"\u003eHSPF2 of 9.8\u003c\/strong\u003e, its airflow of \u003cstrong data-start=\"22843\" data-end=\"22860\"\u003e466 to 647 CFM\u003c\/strong\u003e, its outdoor noise level of \u003cstrong data-start=\"22893\" data-end=\"22905\"\u003e56 dB(A)\u003c\/strong\u003e, its 4D mode, silent mode, iFeel mode, and features designed for daily use. However, it requires a serious installation, especially regarding the \u003cstrong data-start=\"23097\" data-end=\"23113\"\u003e1\/4 - 1\/2 inch\u003c\/strong\u003e piping, \u003cstrong data-start=\"23133\" data-end=\"23146\"\u003e208\/230 V\u003c\/strong\u003e power supply, \u003cstrong data-start=\"23151\" data-end=\"23168\"\u003e14.5 A MCA\u003c\/strong\u003e, \u003cstrong data-start=\"23173\" data-end=\"23188\"\u003e20 A MOP\u003c\/strong\u003e, clearances, and drainage.\u003c\/p\u003e\n\u003cp data-start=\"23223\" data-end=\"23541\"\u003eTo get a clear quote, compare this model with other Zephyr options or schedule an installation in Montreal, Laval, Longueuil, on the South Shore or the North Shore, contact AirGreen. Our team will help you choose the right HVAC solution based on your building, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665925718308,"sku":"ZE-18CB22I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRCB22R32GRANDMONTREAL_ab97f646-e268-40a3-af50-4d4a88813231.png?v=1783695942"},{"product_id":"thermopompe-murale-zephyr-cb22-r32-24000-btu-montreal-laval-rive-sud","title":"ZEPHYR CB22 R32 Wall Heat Pump | 24000 BTU | Montreal, Laval, South Shore","description":"\u003ch1 data-start=\"0\" data-end=\"104\" class=\"PDq2pG_selectionAnchorContainer\"\u003eZephyr CB22 R32 ZE-24CB22 wall-mounted heat pump – A robust 24,000 BTU solution for large spaces\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2 data-start=\"893\" data-end=\"964\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"896\" data-end=\"964\"\u003eA 24,000 BTU wall-mounted heat pump designed for large spaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"966\" data-end=\"1468\"\u003eThe \u003cstrong data-start=\"969\" data-end=\"1017\"\u003eZephyr CB22 R32 ZE-24CB22 wall-mounted heat pump\u003c\/strong\u003e is aimed at owners looking for a powerful, easy-to-use HVAC solution suited for large residential or light commercial spaces. With its \u003cstrong data-start=\"1195\" data-end=\"1226\"\u003e24,000 BTU cooling capacity\u003c\/strong\u003e and \u003cstrong data-start=\"1230\" data-end=\"1266\"\u003e24,000 BTU heating capacity at 8.3 °C\u003c\/strong\u003e, this model is designed to provide serious comfort in a large open area, a spacious ground floor, a large condo, an office, a store, or a room that is difficult to stabilize.\u003c\/p\u003e\n\u003cp data-start=\"1470\" data-end=\"2063\"\u003eAt \u003cstrong data-start=\"1475\" data-end=\"1487\"\u003eAirGreen\u003c\/strong\u003e, we recommend this type of device when the need goes beyond simple occasional cooling. A \u003cstrong data-start=\"1615\" data-end=\"1629\"\u003e24,000 BTU\u003c\/strong\u003e wall-mounted heat pump must be properly sized, well positioned, and installed according to good HVAC practices. In Montreal, Laval, Longueuil, on the South Shore and North Shore, we often see spaces where area alone is not enough to choose the right capacity. You also have to consider \u003cstrong data-start=\"1913\" data-end=\"2062\"\u003einsulation, ceiling height, sun exposure, window area, air circulation, and room layout\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2065\" data-end=\"2475\"\u003eThe Zephyr ZE-24CB22 stands out with its operation on \u003cstrong data-start=\"2124\" data-end=\"2144\"\u003eR-32 refrigerant\u003c\/strong\u003e, its \u003cstrong data-start=\"2161\" data-end=\"2176\"\u003eDC Inverter\u003c\/strong\u003e technology, heating down to \u003cstrong data-start=\"2200\" data-end=\"2210\"\u003e-25 °C\u003c\/strong\u003e, air conditioning mode down to \u003cstrong data-start=\"2243\" data-end=\"2253\"\u003e-15 °C\u003c\/strong\u003e, high airflow, and many comfort functions. It is an interesting machine for customers who want a high-performance wall-mounted heat pump without necessarily opting for a central or multi-zone system.\u003c\/p\u003e\n\u003ch2 data-start=\"2477\" data-end=\"2547\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2480\" data-end=\"2547\"\u003eImportant technical features of the ZE-24CB22 model\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2549\" data-end=\"2638\"\u003eFor the model \u003cstrong data-start=\"2564\" data-end=\"2577\"\u003eZE-24CB22\u003c\/strong\u003e, the main brochure data are as follows:\u003c\/p\u003e\n\u003cp data-start=\"2640\" data-end=\"4351\"\u003e• \u003cstrong data-start=\"2642\" data-end=\"2661\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"2661\" data-end=\"2664\"\u003e• \u003cstrong data-start=\"2666\" data-end=\"2686\"\u003eSeries: CB22 R32\u003c\/strong\u003e\u003cbr data-start=\"2686\" data-end=\"2689\"\u003e• \u003cstrong data-start=\"2691\" data-end=\"2713\"\u003eModel: ZE-24CB22\u003c\/strong\u003e\u003cbr data-start=\"2713\" data-end=\"2716\"\u003e• \u003cstrong data-start=\"2718\" data-end=\"2747\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"2747\" data-end=\"2750\"\u003e• \u003cstrong data-start=\"2752\" data-end=\"2806\"\u003eCooling capacity at 35 °C: 24,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2806\" data-end=\"2809\"\u003e• \u003cstrong data-start=\"2811\" data-end=\"2860\"\u003eHeating capacity at 8.3 °C: 24,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2860\" data-end=\"2863\"\u003e• \u003cstrong data-start=\"2865\" data-end=\"2881\"\u003eSEER2: 19.5\u003c\/strong\u003e\u003cbr data-start=\"2881\" data-end=\"2884\"\u003e• \u003cstrong data-start=\"2886\" data-end=\"2902\"\u003eHSPF2 IV: 9\u003c\/strong\u003e\u003cbr data-start=\"2902\" data-end=\"2905\"\u003e• \u003cstrong data-start=\"2907\" data-end=\"2922\"\u003eEER2: 10.6\u003c\/strong\u003e\u003cbr data-start=\"2922\" data-end=\"2925\"\u003e• \u003cstrong data-start=\"2927\" data-end=\"2959\"\u003eHeating COP at 8.3 °C: 3.3\u003c\/strong\u003e\u003cbr data-start=\"2959\" data-end=\"2962\"\u003e• \u003cstrong data-start=\"2964\" data-end=\"2995\"\u003eHeating COP2: 11.3 Btu\/W\u003c\/strong\u003e\u003cbr data-start=\"2995\" data-end=\"2998\"\u003e• \u003cstrong data-start=\"3000\" data-end=\"3059\"\u003eNominal heating capacity at -8.3 °C: 20,800 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3059\" data-end=\"3062\"\u003e• \u003cstrong data-start=\"3064\" data-end=\"3122\"\u003eMaximum heating capacity at -15 °C: 18,200 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3122\" data-end=\"3125\"\u003e• \u003cstrong data-start=\"3127\" data-end=\"3185\"\u003eMaximum heating capacity at -20 °C: 16,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3185\" data-end=\"3188\"\u003e• \u003cstrong data-start=\"3190\" data-end=\"3212\"\u003eCOP at -15 °C: 1.9\u003c\/strong\u003e\u003cbr data-start=\"3212\" data-end=\"3215\"\u003e• \u003cstrong data-start=\"3217\" data-end=\"3239\"\u003eRefrigerant: R-32\u003c\/strong\u003e\u003cbr data-start=\"3239\" data-end=\"3242\"\u003e• \u003cstrong data-start=\"3244\" data-end=\"3280\"\u003eRefrigerant charge: 47.62 oz\u003c\/strong\u003e\u003cbr data-start=\"3280\" data-end=\"3283\"\u003e• \u003cstrong data-start=\"3285\" data-end=\"3316\"\u003eAirflow: 466 to 647 CFM\u003c\/strong\u003e\u003cbr data-start=\"3316\" data-end=\"3319\"\u003e• \u003cstrong data-start=\"3321\" data-end=\"3386\"\u003eIndoor sound pressure: 49 \/ 46 \/ 39 \/ 37 \/ 33 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"3386\" data-end=\"3389\"\u003e• \u003cstrong data-start=\"3391\" data-end=\"3436\"\u003eOutdoor sound pressure: 60 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"3436\" data-end=\"3439\"\u003e• \u003cstrong data-start=\"3441\" data-end=\"3480\"\u003eVoltage: 208\/230 V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"3480\" data-end=\"3483\"\u003e• \u003cstrong data-start=\"3485\" data-end=\"3530\"\u003eNominal cooling current: 10 A\u003c\/strong\u003e\u003cbr data-start=\"3530\" data-end=\"3533\"\u003e• \u003cstrong data-start=\"3535\" data-end=\"3575\"\u003eNominal heating current: 9.5 A\u003c\/strong\u003e\u003cbr data-start=\"3575\" data-end=\"3578\"\u003e• \u003cstrong data-start=\"3580\" data-end=\"3594\"\u003eMCA: 21 A\u003c\/strong\u003e\u003cbr data-start=\"3594\" data-end=\"3597\"\u003e• \u003cstrong data-start=\"3599\" data-end=\"3613\"\u003eMOP: 25 A\u003c\/strong\u003e\u003cbr data-start=\"3613\" data-end=\"3616\"\u003e• \u003cstrong data-start=\"3618\" data-end=\"3685\"\u003eRequired communication wire: 4\/14 copper stranded 600 V\u003c\/strong\u003e\u003cbr data-start=\"3685\" data-end=\"3688\"\u003e• \u003cstrong data-start=\"3690\" data-end=\"3720\"\u003eCompressor: GMCC rotary\u003c\/strong\u003e\u003cbr data-start=\"3720\" data-end=\"3723\"\u003e• \u003cstrong data-start=\"3725\" data-end=\"3754\"\u003eIndoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"3754\" data-end=\"3757\"\u003e• \u003cstrong data-start=\"3759\" data-end=\"3788\"\u003eOutdoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"3788\" data-end=\"3791\"\u003e• \u003cstrong data-start=\"3793\" data-end=\"3819\"\u003eLiquid pipe: 3\/8 in\u003c\/strong\u003e\u003cbr data-start=\"3819\" data-end=\"3822\"\u003e• \u003cstrong data-start=\"3824\" data-end=\"3846\"\u003eGas pipe: 5\/8 in\u003c\/strong\u003e\u003cbr data-start=\"3846\" data-end=\"3849\"\u003e• \u003cstrong data-start=\"3851\" data-end=\"3897\"\u003eTotal piping length: 10 to 98 ft\u003c\/strong\u003e\u003cbr data-start=\"3897\" data-end=\"3900\"\u003e• \u003cstrong data-start=\"3902\" data-end=\"3936\"\u003eMaximum elevation difference: 50 ft\u003c\/strong\u003e\u003cbr data-start=\"3936\" data-end=\"3939\"\u003e• \u003cstrong data-start=\"3941\" data-end=\"3974\"\u003ePrecharge length: 25 ft\u003c\/strong\u003e\u003cbr data-start=\"3974\" data-end=\"3977\"\u003e• \u003cstrong data-start=\"3979\" data-end=\"4041\"\u003eIndoor unit dimensions: 42 1\/16 x 12 5\/8 x 9 1\/16 in\u003c\/strong\u003e\u003cbr data-start=\"4041\" data-end=\"4044\"\u003e• \u003cstrong data-start=\"4046\" data-end=\"4108\"\u003eOutdoor unit dimensions: 33 7\/8 x 25 1\/2 x 12 3\/16 in\u003c\/strong\u003e\u003cbr data-start=\"4108\" data-end=\"4111\" data-is-only-node=\"\"\u003e• \u003cstrong data-start=\"4113\" data-end=\"4176\"\u003eCooling operating range: -15 °C to 48 °C\u003c\/strong\u003e\u003cbr data-start=\"4176\" data-end=\"4179\"\u003e• \u003cstrong data-start=\"4181\" data-end=\"4238\"\u003eHeating operating range: -25 °C to 24 °C\u003c\/strong\u003e\u003cbr data-start=\"4238\" data-end=\"4241\"\u003e• \u003cstrong data-start=\"4243\" data-end=\"4286\"\u003eZephyr basic warranty: 10 years parts\u003c\/strong\u003e\u003cbr data-start=\"4286\" data-end=\"4289\"\u003e• \u003cstrong data-start=\"4291\" data-end=\"4351\"\u003eLabor warranty: available according to the distributor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4353\" data-end=\"4721\"\u003eThis information is essential before any installation. \u003cstrong data-start=\"4414\" data-end=\"4558\"\u003eA 24,000 BTU wall-mounted heat pump on 208\/230 V with a MCA of 21 A and MOP of 25 A is not installed like a small 9,000 or 12,000 BTU unit.\u003c\/strong\u003e The electrical panel, wiring gauge, required protection, piping routing, and clearances around the outdoor unit must be checked.\u003c\/p\u003e\n\u003ch2 data-start=\"4723\" data-end=\"4781\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4726\" data-end=\"4781\"\u003eHeating and cooling performance in Quebec\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4783\" data-end=\"5170\"\u003eThe brochure states that the Zephyr CB22 heat pump can provide heating down to \u003cstrong data-start=\"4867\" data-end=\"4877\"\u003e-25 °C\u003c\/strong\u003e and cooling operation down to \u003cstrong data-start=\"4924\" data-end=\"4934\"\u003e-15 °C\u003c\/strong\u003e. For Quebec, this is a very important point, especially for customers located in Montreal, Laval, Longueuil, on the North Shore or South Shore, where winters can quickly vary between humidity, frost, thaw, snow, and severe cold.\u003c\/p\u003e\n\u003cp data-start=\"5172\" data-end=\"5285\"\u003eFor the \u003cstrong data-start=\"5187\" data-end=\"5200\"\u003eZE-24CB22\u003c\/strong\u003e model, low-temperature heating performance deserves special attention:\u003c\/p\u003e\n\u003cp data-start=\"5287\" data-end=\"5377\"\u003e• \u003cstrong data-start=\"5289\" data-end=\"5315\"\u003e20,800 BTU\/h at -8.3 °C\u003c\/strong\u003e\u003cbr data-start=\"5315\" data-end=\"5318\"\u003e• \u003cstrong data-start=\"5320\" data-end=\"5345\"\u003e18,200 BTU\/h at -15 °C\u003c\/strong\u003e\u003cbr data-start=\"5345\" data-end=\"5348\"\u003e• \u003cstrong data-start=\"5350\" data-end=\"5375\"\u003e16,000 BTU\/h at -20 °C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5379\" data-end=\"5729\"\u003eThese figures show that the unit maintains useful capacity even when the outside temperature drops. However, it must be clear: \u003cstrong data-start=\"5524\" data-end=\"5640\"\u003ea high-performance wall-mounted heat pump does not always replace 100% of the main heating in all homes\u003c\/strong\u003e, especially in older buildings, poorly insulated, with many windows, or exposed to wind.\u003c\/p\u003e\n\u003cp data-start=\"5731\" data-end=\"6176\"\u003eAt AirGreen, we always explain this reality before installation. A heat pump like the \u003cstrong data-start=\"5832\" data-end=\"5845\"\u003eZE-24CB22\u003c\/strong\u003e can significantly reduce the use of electric baseboards or other supplementary heating, but the actual result will depend on the building. In a large, well-insulated open area, it can provide remarkable comfort. In an older home with closed-off rooms, air distribution can become more complex.\u003c\/p\u003e\n\u003cp data-start=\"6178\" data-end=\"6465\"\u003eIn air conditioning, the capacity of \u003cstrong data-start=\"6211\" data-end=\"6227\"\u003e24,000 BTU\/h\u003c\/strong\u003e allows for treating large spaces. The airflow of \u003cstrong data-start=\"6288\" data-end=\"6305\"\u003e466 to 647 CFM\u003c\/strong\u003e helps move a high volume of air, which is particularly relevant in open rooms or areas where hot air accumulates quickly in summer.\u003c\/p\u003e\n\u003ch2 data-start=\"6467\" data-end=\"6523\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6470\" data-end=\"6523\"\u003eR-32, DC inverter, and stable daily comfort\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"6525\" data-end=\"6827\"\u003eThe \u003cstrong data-start=\"6528\" data-end=\"6553\"\u003eZephyr CB22 ZE-24CB22\u003c\/strong\u003e operates with \u003cstrong data-start=\"6568\" data-end=\"6576\"\u003eR-32\u003c\/strong\u003e, a refrigerant used in several new generations of wall-mounted heat pumps. For the customer, the type of refrigerant may sometimes seem secondary, but it is part of the overall design of the device and good installation practices.\u003c\/p\u003e\n\u003cp data-start=\"6829\" data-end=\"7186\"\u003eThe model also uses \u003cstrong data-start=\"6871\" data-end=\"6893\"\u003evariable frequency\u003c\/strong\u003e technology, often called \u003cstrong data-start=\"6911\" data-end=\"6923\"\u003eInverter\u003c\/strong\u003e. This technology allows the heat pump to adjust its power in real time instead of simply operating on an on-off basis. The desired result is more stable comfort, fewer temperature fluctuations, and better-controlled energy consumption.\u003c\/p\u003e\n\u003cp data-start=\"7188\" data-end=\"7528\"\u003eThe brochure highlights this comfort logic: the machine adjusts its power according to the room’s needs. For an owner, this generally means a more consistent temperature, fewer abrupt cycles, and a better comfort feeling, especially in large spaces where air can be harder to balance.\u003c\/p\u003e\n\u003cp data-start=\"7530\" data-end=\"7817\"\u003e\u003cstrong data-start=\"7530\" data-end=\"7578\"\u003eThe installation remains crucial.\u003c\/strong\u003e Even a good Inverter heat pump can deliver mediocre results if the indoor unit is poorly placed, if the refrigerant lines are improperly installed, if the vacuum is not done correctly, or if the outdoor unit lacks clearance.\u003c\/p\u003e\n\u003ch2 data-start=\"7819\" data-end=\"7896\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"7822\" data-end=\"7896\"\u003eHVAC installation: points to check before confirming the project\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"7898\" data-end=\"8113\"\u003eA 24,000 BTU wall-mounted heat pump installation requires proper planning. At AirGreen, we always consider several factors before recommending or confirming an installation of the \u003cstrong data-start=\"8099\" data-end=\"8112\"\u003eZE-24CB22\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-start=\"8115\" data-end=\"8156\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"8119\" data-end=\"8156\"\u003eLocation of the indoor unit\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"8158\" data-end=\"8442\"\u003eThe indoor unit measures \u003cstrong data-start=\"8184\" data-end=\"8216\"\u003e42 1\/16 x 12 5\/8 x 9 1\/16 in\u003c\/strong\u003e. It is therefore wider than a standard small wall-mounted heat pump. You need to plan for a sufficiently clear wall, a good height, a realistic passage for the piping, and an orientation that promotes air diffusion.\u003c\/p\u003e\n\u003cp data-start=\"8444\" data-end=\"8778\"\u003ePositioning is crucial. \u003cstrong data-start=\"8475\" data-end=\"8532\"\u003eA 24,000 BTU unit can move a lot of air.\u003c\/strong\u003e If installed directly facing a sofa, work table, or bed, the customer may feel a draft even if the temperature is correct. The goal is to distribute air in the main area without causing discomfort.\u003c\/p\u003e\n\u003ch3 data-start=\"8780\" data-end=\"8821\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"8784\" data-end=\"8821\"\u003eOutdoor unit location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"8823\" data-end=\"9186\"\u003eThe outdoor unit measures \u003cstrong data-start=\"8849\" data-end=\"8881\"\u003e33 7\/8 x 25 1\/2 x 12 3\/16 inches\u003c\/strong\u003e. It must be installed on a solid base, with sufficient clearances to allow good air circulation. The indicated outdoor noise level is \u003cstrong data-start=\"9047\" data-end=\"9059\"\u003e60 dB(A)\u003c\/strong\u003e, which must also be considered in denser areas like Montreal, Longueuil, or certain neighborhoods of Laval.\u003c\/p\u003e\n\u003cp data-start=\"9188\" data-end=\"9458\"\u003eIn winter, the location must consider snow, ice, gutters, water drainage, and maintenance access. \u003cstrong data-start=\"9326\" data-end=\"9458\"\u003eA poorly placed outdoor unit can lose performance, accumulate unnecessary ice, or become difficult to maintain.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3 data-start=\"9460\" data-end=\"9491\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"9464\" data-end=\"9491\"\u003e3\/8 - 5\/8 inch piping\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"9493\" data-end=\"9793\"\u003eThe model \u003cstrong data-start=\"9503\" data-end=\"9516\"\u003eZE-24CB22\u003c\/strong\u003e uses \u003cstrong data-start=\"9540\" data-end=\"9558\"\u003e3\/8 inch liquid\u003c\/strong\u003e and \u003cstrong data-start=\"9562\" data-end=\"9576\"\u003e5\/8 inch gas\u003c\/strong\u003e piping. This is a very important point during a replacement. Many customers want to reuse the old lines to reduce work, but you should never assume the existing lines are compatible.\u003c\/p\u003e\n\u003cp data-start=\"9795\" data-end=\"9820\"\u003eWe always check:\u003c\/p\u003e\n\u003cp data-start=\"9822\" data-end=\"10103\"\u003e• the exact diameter of the lines;\u003cbr data-start=\"9853\" data-end=\"9856\"\u003e• the condition of the copper;\u003cbr data-start=\"9875\" data-end=\"9878\"\u003e• the total length;\u003cbr data-start=\"9899\" data-end=\"9902\"\u003e• the old type of refrigerant;\u003cbr data-start=\"9933\" data-end=\"9936\"\u003e• the accessibility of the route;\u003cbr data-start=\"9966\" data-end=\"9969\"\u003e• the possibility of cleanly replacing the lines;\u003cbr data-start=\"10021\" data-end=\"10024\"\u003e• the risks of contamination;\u003cbr data-start=\"10055\" data-end=\"10058\"\u003e• the impact on warranty and performance.\u003c\/p\u003e\n\u003cp data-start=\"10105\" data-end=\"10234\"\u003eIn many situations, \u003cstrong data-start=\"10132\" data-end=\"10185\"\u003ereplacing the piping is the best decision\u003c\/strong\u003e, even if it requires more work initially.\u003c\/p\u003e\n\u003ch3 data-start=\"10236\" data-end=\"10277\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10240\" data-end=\"10277\"\u003ePower supply 208\/230 V\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"10279\" data-end=\"10477\"\u003eThe technical sheet indicates a power supply of \u003cstrong data-start=\"10323\" data-end=\"10352\"\u003e208\/230 V, 60 Hz, single phase\u003c\/strong\u003e, with \u003cstrong data-start=\"10359\" data-end=\"10374\"\u003eMCA of 21 A\u003c\/strong\u003e and \u003cstrong data-start=\"10378\" data-end=\"10393\"\u003eMOP of 25 A\u003c\/strong\u003e. This means an electrical inspection is mandatory before installation.\u003c\/p\u003e\n\u003cp data-start=\"10479\" data-end=\"10770\"\u003eIn some older homes, the electrical panel may already be fully loaded. It is then necessary to check the available space, panel capacity, required breaker, and wire gauge. \u003cstrong data-start=\"10675\" data-end=\"10770\"\u003eA realistic installation price must take this electrical part into account from the start.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"10772\" data-end=\"10826\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10775\" data-end=\"10826\"\u003eNoise level, airflow, and indoor comfort\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"10828\" data-end=\"11109\"\u003eThe ZE-24CB22 has an indoor sound pressure level indicated at \u003cstrong data-start=\"10895\" data-end=\"10927\"\u003e49 \/ 46 \/ 39 \/ 37 \/ 33 dB(A)\u003c\/strong\u003e depending on speeds, with a lower level in silent mode. For a high-capacity unit, these levels are consistent with a machine designed to move a good volume of air.\u003c\/p\u003e\n\u003cp data-start=\"11111\" data-end=\"11499\"\u003eThe airflow of \u003cstrong data-start=\"11129\" data-end=\"11146\"\u003e466 to 647 CFM\u003c\/strong\u003e is particularly important. It allows the unit to better distribute heat or coolness in an open space. But again, it all depends on the actual setup. In an open area, this airflow can be a major advantage. In a closed or poorly oriented room, it can become too powerful if the machine is oversized.\u003c\/p\u003e\n\u003cp data-start=\"11501\" data-end=\"11958\"\u003e\u003cstrong data-start=\"11501\" data-end=\"11547\"\u003eProper sizing is therefore essential.\u003c\/strong\u003e A 24,000 BTU unit should not be chosen simply because it is “stronger.” An overly powerful device can quickly reach the temperature in cooling mode but reduce dehumidification time. Result: the room may feel cool but still humid. Conversely, an undersized unit will run constantly and struggle during very hot or very cold days.\u003c\/p\u003e\n\u003ch2 data-start=\"11960\" data-end=\"12043\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11963\" data-end=\"12043\"\u003ePractical features: 4D mode, silent, night, iFeel, and automatic cleaning\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"12045\" data-end=\"12155\"\u003eThe brochure presents several interesting features for daily comfort. Among the most important:\u003c\/p\u003e\n\u003cp data-start=\"12157\" data-end=\"12828\"\u003e• \u003cstrong data-start=\"12159\" data-end=\"12172\"\u003eNight Mode\u003c\/strong\u003e\u003cbr data-start=\"12172\" data-end=\"12175\"\u003e• \u003cstrong data-start=\"12177\" data-end=\"12193\"\u003eSilent Mode\u003c\/strong\u003e\u003cbr data-start=\"12193\" data-end=\"12196\"\u003e• \u003cstrong data-start=\"12198\" data-end=\"12212\"\u003eiFeel Mode\u003c\/strong\u003e\u003cbr data-start=\"12212\" data-end=\"12215\"\u003e• \u003cstrong data-start=\"12217\" data-end=\"12237\"\u003eQuick Start\u003c\/strong\u003e\u003cbr data-start=\"12237\" data-end=\"12240\"\u003e• \u003cstrong data-start=\"12242\" data-end=\"12263\"\u003eBase Heating\u003c\/strong\u003e\u003cbr data-start=\"12263\" data-end=\"12266\"\u003e• \u003cstrong data-start=\"12268\" data-end=\"12296\"\u003eCompressor Heating\u003c\/strong\u003e\u003cbr data-start=\"12296\" data-end=\"12299\"\u003e• \u003cstrong data-start=\"12301\" data-end=\"12349\"\u003eChassis Heating for Outdoor Base\u003c\/strong\u003e\u003cbr data-start=\"12349\" data-end=\"12352\"\u003e• \u003cstrong data-start=\"12354\" data-end=\"12383\"\u003eFire-Resistant Electrical Box\u003c\/strong\u003e\u003cbr data-start=\"12383\" data-end=\"12386\"\u003e• \u003cstrong data-start=\"12388\" data-end=\"12430\"\u003eAuto-Adaptive Voltage Technology\u003c\/strong\u003e\u003cbr data-start=\"12430\" data-end=\"12433\"\u003e• \u003cstrong data-start=\"12435\" data-end=\"12454\"\u003eTwo-Sided Drain\u003c\/strong\u003e\u003cbr data-start=\"12454\" data-end=\"12457\"\u003e• \u003cstrong data-start=\"12459\" data-end=\"12477\"\u003e24-Hour Timer\u003c\/strong\u003e\u003cbr data-start=\"12477\" data-end=\"12480\"\u003e• \u003cstrong data-start=\"12482\" data-end=\"12509\"\u003eAutomatic Oscillation\u003c\/strong\u003e\u003cbr data-start=\"12509\" data-end=\"12512\"\u003e• \u003cstrong data-start=\"12514\" data-end=\"12525\"\u003e4D Mode\u003c\/strong\u003e\u003cbr data-start=\"12525\" data-end=\"12528\"\u003e• \u003cstrong data-start=\"12530\" data-end=\"12549\"\u003eLED dimmer\u003c\/strong\u003e\u003cbr data-start=\"12549\" data-end=\"12552\"\u003e• \u003cstrong data-start=\"12554\" data-end=\"12594\"\u003e5 indoor fan speeds\u003c\/strong\u003e\u003cbr data-start=\"12594\" data-end=\"12597\"\u003e• \u003cstrong data-start=\"12599\" data-end=\"12628\"\u003eLED wireless remote control\u003c\/strong\u003e\u003cbr data-start=\"12628\" data-end=\"12631\"\u003e• \u003cstrong data-start=\"12633\" data-end=\"12671\"\u003eAutomatic heating 8 °C \/ 46 °F\u003c\/strong\u003e\u003cbr data-start=\"12671\" data-end=\"12674\"\u003e• \u003cstrong data-start=\"12676\" data-end=\"12704\"\u003eReversible drain hose\u003c\/strong\u003e\u003cbr data-start=\"12704\" data-end=\"12707\"\u003e• \u003cstrong data-start=\"12709\" data-end=\"12727\"\u003eTurbo function\u003c\/strong\u003e\u003cbr data-start=\"12727\" data-end=\"12730\"\u003e• \u003cstrong data-start=\"12732\" data-end=\"12757\"\u003eAutomatic defrost\u003c\/strong\u003e\u003cbr data-start=\"12757\" data-end=\"12760\"\u003e• \u003cstrong data-start=\"12762\" data-end=\"12787\"\u003eAutomatic cleaning\u003c\/strong\u003e\u003cbr data-start=\"12787\" data-end=\"12790\"\u003e• \u003cstrong data-start=\"12792\" data-end=\"12828\"\u003eDiffuser position memory\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"12830\" data-end=\"13258\"\u003eThe \u003cstrong data-start=\"12833\" data-end=\"12844\"\u003e4D mode\u003c\/strong\u003e and automatic oscillation allow better air distribution in the room. This is useful to avoid cold or hot spots, especially in a large open area. The \u003cstrong data-start=\"13031\" data-end=\"13045\"\u003eiFeel mode\u003c\/strong\u003e helps adjust comfort based on the temperature sensed near the remote control. The \u003cstrong data-start=\"13131\" data-end=\"13147\"\u003esilent mode\u003c\/strong\u003e and \u003cstrong data-start=\"13154\" data-end=\"13167\"\u003enight mode\u003c\/strong\u003e are convenient for reducing noise when a quieter operation is desired.\u003c\/p\u003e\n\u003cp data-start=\"13260\" data-end=\"13581\"\u003eThe \u003cstrong data-start=\"13263\" data-end=\"13284\"\u003ebasic heating\u003c\/strong\u003e, \u003cstrong data-start=\"13289\" data-end=\"13317\"\u003ecompressor heating\u003c\/strong\u003e, and \u003cstrong data-start=\"13324\" data-end=\"13369\"\u003eheated chassis for the outdoor base\u003c\/strong\u003e are particularly useful in a climate like Quebec’s. These features help support the unit’s winter operation, especially when outdoor conditions are harsh.\u003c\/p\u003e\n\u003ch2 data-start=\"13583\" data-end=\"13629\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"13586\" data-end=\"13629\"\u003eZephyr maintenance, reliability, and warranty\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"13631\" data-end=\"14002\"\u003eThe brochure states a \u003cstrong data-start=\"13655\" data-end=\"13707\"\u003e10-year Zephyr basic parts warranty\u003c\/strong\u003e. It also mentions that a labor warranty is available, depending on the distributor. For the customer, this means clarifying the coverage offered before purchase: parts, labor, diagnostics, travel, maintenance conditions, and warranty registration.\u003c\/p\u003e\n\u003cp data-start=\"14004\" data-end=\"14145\"\u003eA wall-mounted heat pump like the \u003cstrong data-start=\"14036\" data-end=\"14049\"\u003eZE-24CB22\u003c\/strong\u003e must be maintained regularly to retain its efficiency. We especially recommend:\u003c\/p\u003e\n\u003cp data-start=\"14147\" data-end=\"14482\"\u003e• clean the indoor filters frequently;\u003cbr data-start=\"14193\" data-end=\"14196\"\u003e• keep the outdoor unit clear;\u003cbr data-start=\"14232\" data-end=\"14235\"\u003e• check the condensation drain;\u003cbr data-start=\"14271\" data-end=\"14274\"\u003e• monitor abnormal ice buildup;\u003cbr data-start=\"14324\" data-end=\"14327\"\u003e• have the device inspected if the noise changes;\u003cbr data-start=\"14375\" data-end=\"14378\"\u003e• clean the heat exchanger when necessary;\u003cbr data-start=\"14420\" data-end=\"14423\"\u003e• schedule professional maintenance according to usage.\u003c\/p\u003e\n\u003cp data-start=\"14484\" data-end=\"14763\"\u003e\u003cstrong data-start=\"14484\" data-end=\"14599\"\u003eProper maintenance extends the device’s lifespan, maintains performance, and reduces the risk of breakdowns.\u003c\/strong\u003e Features like automatic cleaning or automatic defrosting are useful, but they do not replace a clean installation or serious maintenance.\u003c\/p\u003e\n\u003ch2 data-start=\"14765\" data-end=\"14825\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"14768\" data-end=\"14825\"\u003eWhy choose AirGreen to install the ZE-24CB22\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"14827\" data-end=\"15165\"\u003eAt \u003cstrong data-start=\"14832\" data-end=\"14844\"\u003eAirGreen\u003c\/strong\u003e, we install HVAC systems in houses, condos, plexes, businesses, and offices in Montreal, Laval, Longueuil, on the South Shore, and the North Shore. Our role is not limited to mounting a heat pump on the wall. We analyze the project to choose the right device, the right location, and the right installation method.\u003c\/p\u003e\n\u003cp data-start=\"15167\" data-end=\"15244\"\u003eFor a model like the \u003cstrong data-start=\"15191\" data-end=\"15220\"\u003eZephyr CB22 R32 ZE-24CB22\u003c\/strong\u003e, our team checks:\u003c\/p\u003e\n\u003cp data-start=\"15246\" data-end=\"15575\"\u003e• required capacity according to the space;\u003cbr data-start=\"15286\" data-end=\"15289\"\u003e• optimal location of the indoor unit;\u003cbr data-start=\"15335\" data-end=\"15338\"\u003e• location of the outdoor unit;\u003cbr data-start=\"15376\" data-end=\"15379\"\u003e• piping routing;\u003cbr data-start=\"15409\" data-end=\"15412\"\u003e• electrical compatibility;\u003cbr data-start=\"15442\" data-end=\"15445\"\u003e• clearances;\u003cbr data-start=\"15463\" data-end=\"15466\"\u003e• drainage;\u003cbr data-start=\"15480\" data-end=\"15483\"\u003e• winter constraints;\u003cbr data-start=\"15509\" data-end=\"15512\"\u003e• access for maintenance;\u003cbr data-start=\"15539\" data-end=\"15542\"\u003e• the client’s actual expectations.\u003c\/p\u003e\n\u003cp data-start=\"15577\" data-end=\"15826\"\u003eThis approach avoids several common mistakes: device too powerful, poor air distribution, outdoor unit too close to an obstacle, incompatible refrigerant line, undervalued electrical circuit, or installation difficult to maintain.\u003c\/p\u003e\n\u003cp data-start=\"15828\" data-end=\"16231\"\u003eThe \u003cstrong data-start=\"15831\" data-end=\"15844\"\u003eZE-24CB22\u003c\/strong\u003e is an interesting wall-mounted heat pump for large spaces that require good heating and cooling capacity. With its \u003cstrong data-start=\"15985\" data-end=\"15999\"\u003e24,000 BTU\u003c\/strong\u003e, \u003cstrong data-start=\"16005\" data-end=\"16025\"\u003eR-32 refrigerant\u003c\/strong\u003e, operation down to \u003cstrong data-start=\"16054\" data-end=\"16077\"\u003e-25 °C in heating mode\u003c\/strong\u003e, \u003cstrong data-start=\"16083\" data-end=\"16104\"\u003ehigh airflow\u003c\/strong\u003e, \u003cstrong data-start=\"16110\" data-end=\"16121\"\u003e4D mode\u003c\/strong\u003e, and \u003cstrong data-start=\"16128\" data-end=\"16157\"\u003e10-year parts warranty\u003c\/strong\u003e, it can be a solid HVAC solution for many projects.\u003c\/p\u003e\n\u003cp data-start=\"16233\" data-end=\"16559\"\u003eTo get a clear quote, compare this model with other wall-mounted heat pumps or schedule an installation in Montreal, Laval, Longueuil, on the South Shore or the North Shore, contact \u003cstrong data-start=\"16426\" data-end=\"16438\"\u003eAirGreen\u003c\/strong\u003e. Our team will help you choose a solution suited to your building, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665925816612,"sku":"ZE-24CB22I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRCB22R32GRANDMONTREAL_c834f35b-c9bd-4d70-a050-3cd92ecb6753.png?v=1783695936"},{"product_id":"thermopompe-murale-zephyr-cb25-r454b-9000-btu-115v","title":"ZEPHYR CB25 R454B Wall Heat Pump | 9000 BTU 115V","description":"\u003ch1 data-start=\"0\" data-end=\"67\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2\" data-end=\"67\"\u003eZephyr ZE-09DB25 Wall-Mounted Heat Pump – 9,000 BTU, 115 V, R454B\u003c\/strong\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2 data-start=\"69\" data-end=\"158\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"72\" data-end=\"158\"\u003eA compact, efficient wall-mounted heat pump designed for year-round comfort\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"160\" data-end=\"689\"\u003eThe \u003cstrong data-start=\"163\" data-end=\"202\"\u003eZephyr ZE-09DB25 Wall-Mounted Heat Pump\u003c\/strong\u003e is an interesting HVAC solution for homeowners looking for a wall unit with \u003cstrong data-start=\"298\" data-end=\"328\"\u003e9,000 BTU cooling capacity\u003c\/strong\u003e, capable of providing stable comfort in a bedroom, office, condo, small living room, closed room, or moderately sized residential space. At AirGreen, we often see this type of model as a very relevant option when the customer wants an efficient, discreet, affordable heat pump well suited to Quebec’s climate realities.\u003c\/p\u003e\n\u003cp data-start=\"691\" data-end=\"1218\"\u003eUnlike more powerful units designed for large open areas, the \u003cstrong data-start=\"773\" data-end=\"786\"\u003eZE-09DB25\u003c\/strong\u003e positions itself as a compact but serious wall-mounted heat pump. It offers a \u003cstrong data-start=\"882\" data-end=\"914\"\u003e9,000 BTU cooling capacity\u003c\/strong\u003e and a heating capacity rated at \u003cstrong data-start=\"956\" data-end=\"979\"\u003e12,000 BTU at 8.3 °C\u003c\/strong\u003e, making it a versatile device for everyday heating and cooling needs. It operates with \u003cstrong data-start=\"1100\" data-end=\"1121\"\u003eR454B refrigerant\u003c\/strong\u003e, a new generation refrigerant increasingly present in recent HVAC systems.\u003c\/p\u003e\n\u003cp data-start=\"1220\" data-end=\"1626\"\u003eAccording to the Zephyr CB25 brochure, this model is designed to operate in heating mode down to \u003cstrong data-start=\"1309\" data-end=\"1319\"\u003e-30 °C\u003c\/strong\u003e and in cooling mode down to \u003cstrong data-start=\"1348\" data-end=\"1358\"\u003e-15 °C\u003c\/strong\u003e outdoor temperature, with several comfort functions such as \u003cstrong data-start=\"1431\" data-end=\"1447\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"1452\" data-end=\"1465\"\u003enight mode\u003c\/strong\u003e, \u003cstrong data-start=\"1470\" data-end=\"1484\"\u003eiFeel mode\u003c\/strong\u003e, \u003cstrong data-start=\"1489\" data-end=\"1509\"\u003equick start\u003c\/strong\u003e, \u003cstrong data-start=\"1514\" data-end=\"1525\"\u003e4D mode\u003c\/strong\u003e, \u003cstrong data-start=\"1530\" data-end=\"1555\"\u003eautomatic cleaning\u003c\/strong\u003e, and \u003cstrong data-start=\"1562\" data-end=\"1587\"\u003eautomatic defrost\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-start=\"1628\" data-end=\"1690\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1631\" data-end=\"1690\"\u003eImportant technical features to know\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1692\" data-end=\"1793\"\u003eFor model \u003cstrong data-start=\"1707\" data-end=\"1720\"\u003eZE-09DB25\u003c\/strong\u003e, the main data listed in the brochure are as follows:\u003c\/p\u003e\n\u003cp data-start=\"1795\" data-end=\"2767\"\u003e\u003cstrong data-start=\"1795\" data-end=\"1814\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"1814\" data-end=\"1817\"\u003e\u003cstrong data-start=\"1817\" data-end=\"1833\"\u003eSeries: CB25\u003c\/strong\u003e\u003cbr data-start=\"1833\" data-end=\"1836\"\u003e\u003cstrong data-start=\"1836\" data-end=\"1858\"\u003eModel: ZE-09DB25\u003c\/strong\u003e\u003cbr data-start=\"1858\" data-end=\"1861\"\u003e\u003cstrong data-start=\"1861\" data-end=\"1890\"\u003eType: Wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"1890\" data-end=\"1893\"\u003e\u003cstrong data-start=\"1893\" data-end=\"1936\"\u003eCooling capacity: 9,000 BTU\u003c\/strong\u003e\u003cbr data-start=\"1936\" data-end=\"1939\"\u003e\u003cstrong data-start=\"1939\" data-end=\"1986\"\u003eHeating capacity at 8.3 °C: 12,000 BTU\u003c\/strong\u003e\u003cbr data-start=\"1986\" data-end=\"1989\"\u003e\u003cstrong data-start=\"1989\" data-end=\"2012\"\u003eRefrigerant: R454B\u003c\/strong\u003e\u003cbr data-start=\"2012\" data-end=\"2015\"\u003e\u003cstrong data-start=\"2015\" data-end=\"2050\"\u003eVoltage: 115 V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"2050\" data-end=\"2053\"\u003e\u003cstrong data-start=\"2053\" data-end=\"2069\"\u003eSEER2: 22.0\u003c\/strong\u003e\u003cbr data-start=\"2069\" data-end=\"2072\"\u003e\u003cstrong data-start=\"2072\" data-end=\"2090\"\u003eHSPF2 IV: 9.5\u003c\/strong\u003e\u003cbr data-start=\"2090\" data-end=\"2093\"\u003e\u003cstrong data-start=\"2093\" data-end=\"2109\"\u003eEER2: 12.25\u003c\/strong\u003e\u003cbr data-start=\"2109\" data-end=\"2112\"\u003e\u003cstrong data-start=\"2112\" data-end=\"2145\"\u003eHeating COP at 8.3 °C: 3.40\u003c\/strong\u003e\u003cbr data-start=\"2145\" data-end=\"2148\"\u003e\u003cstrong data-start=\"2148\" data-end=\"2174\"\u003eEnergy Star V6.1: yes\u003c\/strong\u003e\u003cbr data-start=\"2174\" data-end=\"2177\"\u003e\u003cstrong data-start=\"2177\" data-end=\"2208\"\u003eAirflow: 253 to 400 CFM\u003c\/strong\u003e\u003cbr data-start=\"2208\" data-end=\"2211\"\u003e\u003cstrong data-start=\"2211\" data-end=\"2276\"\u003eIndoor sound pressure: 42 \/ 40 \/ 37 \/ 35 \/ 32 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"2276\" data-end=\"2279\"\u003e\u003cstrong data-start=\"2279\" data-end=\"2324\"\u003eOutdoor sound pressure: 53 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"2324\" data-end=\"2327\"\u003e\u003cstrong data-start=\"2327\" data-end=\"2341\"\u003eMOP: 20 A\u003c\/strong\u003e\u003cbr data-start=\"2341\" data-end=\"2344\"\u003e\u003cstrong data-start=\"2344\" data-end=\"2358\"\u003eMCA: 16 A\u003c\/strong\u003e\u003cbr data-start=\"2358\" data-end=\"2361\"\u003e\u003cstrong data-start=\"2361\" data-end=\"2392\"\u003eLiquid piping: 1\/4 in\u003c\/strong\u003e\u003cbr data-start=\"2392\" data-end=\"2395\"\u003e\u003cstrong data-start=\"2395\" data-end=\"2422\"\u003eGas piping: 3\/8 in\u003c\/strong\u003e\u003cbr data-start=\"2422\" data-end=\"2425\"\u003e\u003cstrong data-start=\"2425\" data-end=\"2467\"\u003ePiping length: 10 to 65 feet\u003c\/strong\u003e\u003cbr data-start=\"2467\" data-end=\"2470\"\u003e\u003cstrong data-start=\"2470\" data-end=\"2507\"\u003eMaximum elevation difference: 50 feet\u003c\/strong\u003e\u003cbr data-start=\"2507\" data-end=\"2510\"\u003e\u003cstrong data-start=\"2510\" data-end=\"2548\"\u003ePrecharge of piping: 25 feet\u003c\/strong\u003e\u003cbr data-start=\"2548\" data-end=\"2551\"\u003e\u003cstrong data-start=\"2551\" data-end=\"2581\"\u003eCompressor: GMCC rotary\u003c\/strong\u003e\u003cbr data-start=\"2581\" data-end=\"2584\"\u003e\u003cstrong data-start=\"2584\" data-end=\"2601\"\u003eExpansion valve: EEV\u003c\/strong\u003e\u003cbr data-start=\"2601\" data-end=\"2604\"\u003e\u003cstrong data-start=\"2604\" data-end=\"2633\"\u003eIndoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"2633\" data-end=\"2636\"\u003e\u003cstrong data-start=\"2636\" data-end=\"2665\"\u003eOutdoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"2665\" data-end=\"2668\"\u003e\u003cstrong data-start=\"2668\" data-end=\"2704\"\u003eBasic warranty: 10 years parts\u003c\/strong\u003e\u003cbr data-start=\"2704\" data-end=\"2707\"\u003e\u003cstrong data-start=\"2707\" data-end=\"2767\"\u003eLabor warranty: available depending on the distributor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2769\" data-end=\"3075\"\u003eThe dimensions indicated in the brochure are in \u003cstrong data-start=\"2826\" data-end=\"2839\"\u003eL × H × D\u003c\/strong\u003e format. For the indoor unit, the dimension is \u003cstrong data-start=\"2886\" data-end=\"2919\"\u003e33 7\/16 × 11 9\/16 × 8 1\/16 in\u003c\/strong\u003e, approximately \u003cstrong data-start=\"2934\" data-end=\"2961\"\u003e33.44 × 11.56 × 8.06 in\u003c\/strong\u003e. For the outdoor unit, the dimension is \u003cstrong data-start=\"3008\" data-end=\"3031\"\u003e31 7\/8 × 23 × 11 in\u003c\/strong\u003e, approximately \u003cstrong data-start=\"3046\" data-end=\"3074\"\u003e31.88 × 23.00 × 11.00 in\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-start=\"3077\" data-end=\"3140\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3080\" data-end=\"3140\"\u003eAn ideal 9,000 BTU heat pump for targeted rooms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3142\" data-end=\"3525\"\u003eThe \u003cstrong data-start=\"3145\" data-end=\"3158\"\u003eZE-09DB25\u003c\/strong\u003e is particularly suited for projects where the need is not to cool an entire house but rather to treat a specific area. This could be a master bedroom, a home office, a closed family room, a small living space, a condo, a room above a garage, or a space that becomes too hot in summer and too cold in winter.\u003c\/p\u003e\n\u003cp data-start=\"3527\" data-end=\"4086\"\u003eAt AirGreen, we always remind that a wall-mounted heat pump must be chosen according to the actual building configuration, not just the number of BTUs. A \u003cstrong data-start=\"3707\" data-end=\"3720\"\u003e9,000 BTU\u003c\/strong\u003e unit can be perfect in a well-insulated room but insufficient in a very open, highly windowed space or one exposed to the sun all day. Conversely, choosing a machine that is too powerful for a small room can create discomfort, especially in cooling mode, as the device may quickly reach the desired temperature without properly dehumidifying the air.\u003c\/p\u003e\n\u003cp data-start=\"4088\" data-end=\"4439\"\u003eThat is why we always analyze several elements before recommending this type of device: \u003cstrong data-start=\"4188\" data-end=\"4438\"\u003eroom size, insulation, window orientation, ceiling height, sun exposure, air circulation, possible location of the indoor unit, distance to the outdoor unit, electrical access, and condensation drainage\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-start=\"4441\" data-end=\"4511\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4444\" data-end=\"4511\"\u003eHeating performance: an important factor for Quebec\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4513\" data-end=\"4824\"\u003eOne of the strengths of this heat pump is its heating operating range down to \u003cstrong data-start=\"4608\" data-end=\"4618\"\u003e-30 °C\u003c\/strong\u003e. For Montreal, Laval, Longueuil, the South Shore, and the North Shore, this feature is very important because a wall-mounted heat pump must be able to operate in real winter conditions.\u003c\/p\u003e\n\u003cp data-start=\"4826\" data-end=\"4891\"\u003eThe technical sheet indicates the following heating capacities:\u003c\/p\u003e\n\u003cp data-start=\"4893\" data-end=\"5096\"\u003e\u003cstrong data-start=\"4893\" data-end=\"4936\"\u003eNominal capacity at -8.3 °C: 9,300 BTU\u003c\/strong\u003e\u003cbr data-start=\"4936\" data-end=\"4939\"\u003e\u003cstrong data-start=\"4939\" data-end=\"4981\"\u003eMaximum capacity at -15 °C: 9,200 BTU\u003c\/strong\u003e\u003cbr data-start=\"4981\" data-end=\"4984\"\u003e\u003cstrong data-start=\"4984\" data-end=\"5006\"\u003eCOP at -15 °C: 1.9\u003c\/strong\u003e\u003cbr data-start=\"5006\" data-end=\"5009\"\u003e\u003cstrong data-start=\"5009\" data-end=\"5051\"\u003eMaximum capacity at -20 °C: 6,900 BTU\u003c\/strong\u003e\u003cbr data-start=\"5051\" data-end=\"5054\"\u003e\u003cstrong data-start=\"5054\" data-end=\"5096\"\u003eMaximum capacity at -25 °C: 5,900 BTU\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5098\" data-end=\"5522\"\u003eThese figures are very useful. They show that the heat pump can continue to operate at low temperatures, but its capacity decreases as the cold intensifies. This is normal for a heat pump. In a well-insulated room, it can cover a large part of the heating needs. In a more challenging room, supplementary heating may still be necessary on the coldest days.\u003c\/p\u003e\n\u003cp data-start=\"5524\" data-end=\"5756\"\u003eAt AirGreen, we always make this clear: \u003cstrong data-start=\"5586\" data-end=\"5755\"\u003ea high-performance wall-mounted heat pump can significantly reduce the use of traditional electric heating, but it must be properly sized and installed\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-start=\"5758\" data-end=\"5843\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5761\" data-end=\"5843\"\u003eThe R454B refrigerant: a new generation for modern installations\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"5845\" data-end=\"6135\"\u003eThe \u003cstrong data-start=\"5848\" data-end=\"5861\"\u003eZE-09DB25\u003c\/strong\u003e operates with \u003cstrong data-start=\"5876\" data-end=\"5885\"\u003eR454B\u003c\/strong\u003e, a refrigerant used in several new generations of HVAC equipment. For the customer, the type of refrigerant may seem secondary, but it influences the device’s design, installation practices, and technical requirements.\u003c\/p\u003e\n\u003cp data-start=\"6137\" data-end=\"6463\"\u003eWith new refrigerants, installation must be especially precise. Best practices must be followed: \u003cstrong data-start=\"6264\" data-end=\"6462\"\u003ecompatible piping, clean flares, leak testing, thorough vacuuming, adherence to minimum and maximum lengths, electrical compliance, and final operational verification\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"6465\" data-end=\"6698\"\u003eA modern device like the Zephyr ZE-09DB25 should not be installed quickly or roughly. Poor installation can affect performance, noise levels, compressor lifespan, and even the warranty.\u003c\/p\u003e\n\u003ch2 data-start=\"6700\" data-end=\"6783\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6703\" data-end=\"6783\"\u003eIndoor comfort: 4D mode, automatic oscillation, and inverter technology\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"6785\" data-end=\"7029\"\u003eThe brochure highlights the \u003cstrong data-start=\"6813\" data-end=\"6824\"\u003e4D mode\u003c\/strong\u003e and \u003cstrong data-start=\"6830\" data-end=\"6857\"\u003eautomatic oscillation\u003c\/strong\u003e, which help distribute air better throughout the room. This feature is important to avoid cold or hot spots and achieve a more balanced temperature.\u003c\/p\u003e\n\u003cp data-start=\"7031\" data-end=\"7410\"\u003eVariable frequency technology, also called \u003cstrong data-start=\"7082\" data-end=\"7106\"\u003einverter technology\u003c\/strong\u003e, allows the heat pump to adjust its power in real time. Instead of operating only on\/off like an older device, it modulates its capacity according to needs. Result: \u003cstrong data-start=\"7304\" data-end=\"7409\"\u003eless temperature variation, better comfort, and more controlled energy consumption\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"7412\" data-end=\"7478\"\u003eThe model also includes several useful everyday functions:\u003c\/p\u003e\n\u003cp data-start=\"7480\" data-end=\"8191\"\u003e\u003cstrong data-start=\"7480\" data-end=\"7493\"\u003eNight mode\u003c\/strong\u003e to reduce operating intensity during sleep.\u003cbr data-start=\"7556\" data-end=\"7559\"\u003e\u003cstrong data-start=\"7559\" data-end=\"7575\"\u003eSilent mode\u003c\/strong\u003e for quieter operation.\u003cbr data-start=\"7612\" data-end=\"7615\"\u003e\u003cstrong data-start=\"7615\" data-end=\"7629\"\u003eiFeel mode\u003c\/strong\u003e to adjust comfort according to the temperature sensed near the remote control.\u003cbr data-start=\"7709\" data-end=\"7712\"\u003e\u003cstrong data-start=\"7712\" data-end=\"7730\"\u003eTurbo function\u003c\/strong\u003e to reach the desired temperature faster.\u003cbr data-start=\"7786\" data-end=\"7789\"\u003e\u003cstrong data-start=\"7789\" data-end=\"7807\"\u003e24-hour timer\u003c\/strong\u003e to schedule operation.\u003cbr data-start=\"7842\" data-end=\"7845\"\u003e\u003cstrong data-start=\"7845\" data-end=\"7874\"\u003eLED wireless remote control\u003c\/strong\u003e for simple control.\u003cbr data-start=\"7899\" data-end=\"7902\"\u003e\u003cstrong data-start=\"7902\" data-end=\"7921\"\u003eLED dimmer\u003c\/strong\u003e to reduce the display brightness.\u003cbr data-start=\"7964\" data-end=\"7967\"\u003e\u003cstrong data-start=\"7967\" data-end=\"8003\"\u003eDiffuser position memory\u003c\/strong\u003e to restore the preferred setting.\u003cbr data-start=\"8038\" data-end=\"8041\"\u003e\u003cstrong data-start=\"8041\" data-end=\"8066\"\u003eAutomatic cleaning\u003c\/strong\u003e to help keep the indoor unit cleaner.\u003cbr data-start=\"8121\" data-end=\"8124\"\u003e\u003cstrong data-start=\"8124\" data-end=\"8149\"\u003eAutomatic defrost\u003c\/strong\u003e to support operation in winter.\u003c\/p\u003e\n\u003ch2 data-start=\"8193\" data-end=\"8264\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"8196\" data-end=\"8264\"\u003eA 115 V unit: convenient, but to be checked before installation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"8266\" data-end=\"8558\"\u003eA very important point of the \u003cstrong data-start=\"8300\" data-end=\"8313\"\u003eZE-09DB25\u003c\/strong\u003e model is its \u003cstrong data-start=\"8338\" data-end=\"8347\"\u003e115 V\u003c\/strong\u003e power supply. This can be advantageous in some projects, as several small 9,000 BTU wall-mounted heat pumps use this voltage type. However, this does not mean it can be connected just any way.\u003c\/p\u003e\n\u003cp data-start=\"8560\" data-end=\"8802\"\u003eThe technical sheet indicates a \u003cstrong data-start=\"8590\" data-end=\"8605\"\u003e16 A MCA\u003c\/strong\u003e and a \u003cstrong data-start=\"8612\" data-end=\"8627\"\u003e20 A MOP\u003c\/strong\u003e. This means that an appropriate circuit with the correct electrical protection must be planned. The nominal current is \u003cstrong data-start=\"8744\" data-end=\"8772\"\u003e8.8 A in cooling\u003c\/strong\u003e and \u003cstrong data-start=\"8779\" data-end=\"8801\"\u003e9.3 A in heating\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"8804\" data-end=\"9152\"\u003eBefore confirming the installation, we always check the electrical panel, circuit availability, wire gauge, breaker location, and installation compliance. In some older buildings in Montreal or Longueuil, this step is essential because panels may already be full or poorly organized.\u003c\/p\u003e\n\u003ch2 data-start=\"9154\" data-end=\"9222\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"9157\" data-end=\"9222\"\u003e1\/4 - 3\/8 inch piping: an essential detail in replacement  \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"9224\" data-end=\"9536\"\u003eThe \u003cstrong data-start=\"9227\" data-end=\"9240\"\u003eZE-09DB25\u003c\/strong\u003e uses \u003cstrong data-start=\"9267\" data-end=\"9293\"\u003e1\/4 inch liquid\u003c\/strong\u003e and \u003cstrong data-start=\"9297\" data-end=\"9319\"\u003e3\/8 inch gas piping\u003c\/strong\u003e. This information is crucial when replacing an old heat pump. You should never assume existing lines are compatible just because an old wall unit was already installed.  \u003c\/p\u003e\n\u003cp data-start=\"9538\" data-end=\"9578\"\u003eWhen replacing, we check:  \u003c\/p\u003e\n\u003cp data-start=\"9580\" data-end=\"9877\"\u003e\u003cstrong data-start=\"9580\" data-end=\"9621\"\u003ethe diameter of the refrigerant lines;  \u003c\/strong\u003e\u003cbr data-start=\"9621\" data-end=\"9624\"\u003e\u003cstrong data-start=\"9624\" data-end=\"9652\"\u003ethe condition of the piping;  \u003c\/strong\u003e\u003cbr data-start=\"9652\" data-end=\"9655\"\u003e\u003cstrong data-start=\"9655\" data-end=\"9690\"\u003ethe total length of the run;  \u003c\/strong\u003e\u003cbr data-start=\"9690\" data-end=\"9693\"\u003e\u003cstrong data-start=\"9693\" data-end=\"9726\"\u003ethe old refrigerant used;  \u003c\/strong\u003e\u003cbr data-start=\"9726\" data-end=\"9729\"\u003e\u003cstrong data-start=\"9729\" data-end=\"9784\"\u003ethe possibility to clean or replace the lines;  \u003c\/strong\u003e\u003cbr data-start=\"9784\" data-end=\"9787\"\u003e\u003cstrong data-start=\"9787\" data-end=\"9824\"\u003eaccessibility of the wall passage;  \u003c\/strong\u003e\u003cbr data-start=\"9824\" data-end=\"9827\"\u003e\u003cstrong data-start=\"9827\" data-end=\"9877\"\u003ecompliance with the manufacturer’s requirements.  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"9879\" data-end=\"10132\"\u003eThe brochure indicates a total pipe length of \u003cstrong data-start=\"9936\" data-end=\"9953\"\u003e10 to 65 feet\u003c\/strong\u003e, with a precharge designed for \u003cstrong data-start=\"9986\" data-end=\"9998\"\u003e25 feet\u003c\/strong\u003e. This must be taken into account when calculating the installation, especially if the outdoor unit is placed far from the indoor unit.  \u003c\/p\u003e\n\u003ch2 data-start=\"10134\" data-end=\"10208\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10137\" data-end=\"10208\"\u003eIndoor unit location: small size, big importance  \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"10210\" data-end=\"10426\"\u003eEven though the ZE-09DB25 is a compact unit, its location must be chosen carefully. A poor position can create an unpleasant draft, poor air distribution, or uneven temperature in the room.  \u003c\/p\u003e\n\u003cp data-start=\"10428\" data-end=\"10710\"\u003eWe generally avoid placing the unit directly above a bed, desk, or sofa if the air is likely to blow directly on occupants for several hours. Instead, we look for a location that allows air to circulate naturally in the room.  \u003c\/p\u003e\n\u003cp data-start=\"10712\" data-end=\"11086\"\u003eIn Montreal condos and plexes, you also need to consider brick walls, shared walls, plaster ceilings, condominium restrictions, and exterior aesthetics. On the South Shore or North Shore, houses sometimes offer more flexibility, but you still need to think about drainage, pipe distance, and future access for maintenance.  \u003c\/p\u003e\n\u003ch2 data-start=\"11088\" data-end=\"11156\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11091\" data-end=\"11156\"\u003eOutdoor unit location: noise, snow, and maintenance  \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"11158\" data-end=\"11414\"\u003eThe outdoor unit of the ZE-09DB25 has a sound pressure level of \u003cstrong data-start=\"11228\" data-end=\"11240\"\u003e53 dB(A)\u003c\/strong\u003e, which remains reasonable for a wall-mounted heat pump. However, the location must be chosen carefully, especially in dense neighborhoods where neighbors are close.\u003c\/p\u003e\n\u003cp data-start=\"11416\" data-end=\"11679\"\u003eThe outdoor unit must be installed on a stable base, with the necessary clearances to ensure good air circulation. In Quebec, you also need to consider snow, ice, water accumulation from the roof, and access for maintenance.  \u003c\/p\u003e\n\u003cp data-start=\"11681\" data-end=\"11909\"\u003eAt AirGreen, we always recommend an installation that takes winter into account. A unit that is too low, poorly protected, or installed in an area where snow accumulates can lose efficiency and require more maintenance.  \u003c\/p\u003e\n\u003ch2 data-start=\"11911\" data-end=\"11977\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11914\" data-end=\"11977\"\u003eHVAC Maintenance: preserving performance year after year  \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"11979\" data-end=\"12325\"\u003eA well-installed wall-mounted heat pump must also be properly maintained. The owner can perform some maintenance themselves, especially regular filter cleaning. However, periodic professional inspection is still recommended to preserve performance and detect problems before they become costly.  \u003c\/p\u003e\n\u003cp data-start=\"12327\" data-end=\"12356\"\u003eWe especially recommend:  \u003c\/p\u003e\n\u003cp data-start=\"12358\" data-end=\"12758\"\u003e\u003cstrong data-start=\"12358\" data-end=\"12397\"\u003eClean the filters regularly;  \u003c\/strong\u003e\u003cbr data-start=\"12397\" data-end=\"12400\"\u003e\u003cstrong data-start=\"12400\" data-end=\"12454\"\u003eEnsure the condensation drain remains free;  \u003c\/strong\u003e\u003cbr data-start=\"12454\" data-end=\"12457\"\u003e\u003cstrong data-start=\"12457\" data-end=\"12495\"\u003eKeep the outdoor unit clear;  \u003c\/strong\u003e\u003cbr data-start=\"12495\" data-end=\"12498\"\u003e\u003cstrong data-start=\"12498\" data-end=\"12568\"\u003eRemove leaves, dust, snow, and debris around the unit;  \u003c\/strong\u003e\u003cbr data-start=\"12568\" data-end=\"12571\"\u003e\u003cstrong data-start=\"12571\" data-end=\"12609\"\u003eMonitor for unusual noises;  \u003c\/strong\u003e\u003cbr data-start=\"12609\" data-end=\"12612\"\u003e\u003cstrong data-start=\"12612\" data-end=\"12669\"\u003eHave the unit inspected if performance decreases;  \u003c\/strong\u003e\u003cbr data-start=\"12669\" data-end=\"12672\"\u003e\u003cstrong data-start=\"12672\" data-end=\"12758\"\u003eSchedule professional cleaning when the indoor heat exchanger becomes dirty.  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"12760\" data-end=\"12929\"\u003eFeatures like \u003cstrong data-start=\"12783\" data-end=\"12808\"\u003eautomatic cleaning\u003c\/strong\u003e and \u003cstrong data-start=\"12815\" data-end=\"12840\"\u003eautomatic defrosting\u003c\/strong\u003e improve daily use, but they do not replace serious maintenance.  \u003c\/p\u003e\n\u003ch2 data-start=\"12931\" data-end=\"12996\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"12934\" data-end=\"12996\"\u003eMistakes to avoid before buying a 9,000 BTU heat pump  \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"12998\" data-end=\"13119\"\u003eIn our experience, many problems stem from a poor initial choice. Here are the most common mistakes:  \u003c\/p\u003e\n\u003cp data-start=\"13121\" data-end=\"13677\"\u003e\u003cstrong data-start=\"13121\" data-end=\"13194\"\u003eChoose a 9,000 BTU heat pump without verifying the actual area.  \u003c\/strong\u003e\u003cbr data-start=\"13194\" data-end=\"13197\"\u003e\u003cstrong data-start=\"13197\" data-end=\"13262\"\u003eInstall the unit in a room that is too large or too open.  \u003c\/strong\u003e\u003cbr data-start=\"13262\" data-end=\"13265\"\u003e\u003cstrong data-start=\"13265\" data-end=\"13320\"\u003eNeglect sun exposure and window placement.  \u003c\/strong\u003e\u003cbr data-start=\"13320\" data-end=\"13323\"\u003e\u003cstrong data-start=\"13323\" data-end=\"13369\"\u003eForget to check the electrical panel.  \u003c\/strong\u003e\u003cbr data-start=\"13369\" data-end=\"13372\"\u003e\u003cstrong data-start=\"13372\" data-end=\"13427\"\u003eReuse old piping without validation.  \u003c\/strong\u003e\u003cbr data-start=\"13427\" data-end=\"13430\"\u003e\u003cstrong data-start=\"13430\" data-end=\"13479\"\u003ePlace the indoor unit in the wrong location.  \u003c\/strong\u003e\u003cbr data-start=\"13479\" data-end=\"13482\"\u003e\u003cstrong data-start=\"13482\" data-end=\"13549\"\u003eInstall the outdoor unit too close to a wall or neighbor.  \u003c\/strong\u003e\u003cbr data-start=\"13549\" data-end=\"13552\"\u003e\u003cstrong data-start=\"13552\" data-end=\"13614\"\u003eIgnore snow and winter clearance.  \u003c\/strong\u003e\u003cbr data-start=\"13614\" data-end=\"13617\"\u003e\u003cstrong data-start=\"13617\" data-end=\"13677\"\u003eCompare price only without considering installation.  \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"13679\" data-end=\"13890\"\u003eA good heat pump that is poorly installed will rarely deliver good results. Conversely, a well-chosen, well-installed, and well-maintained heat pump can provide remarkable comfort for many years.  \u003c\/p\u003e\n\u003ch2 data-start=\"13892\" data-end=\"13959\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"13895\" data-end=\"13959\"\u003eWhy choose AirGreen to install the Zephyr ZE-09DB25  \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"13961\" data-end=\"14247\"\u003eAt AirGreen, we install, maintain, and repair HVAC systems in Greater Montreal, including \u003cstrong data-start=\"14071\" data-end=\"14134\"\u003eMontreal, Laval, Longueuil, on the South Shore and the North Shore\u003c\/strong\u003e. Our approach is simple: offer the right device, in the right place, with a clean and compliant installation.\u003c\/p\u003e\n\u003cp data-start=\"14249\" data-end=\"14522\"\u003eFor a model like the \u003cstrong data-start=\"14273\" data-end=\"14293\"\u003eZephyr ZE-09DB25\u003c\/strong\u003e, we first verify the feasibility of the project: required capacity, indoor location, outdoor location, pipe length, electrical supply, drainage, maintenance access, and the client’s real expectations.\u003c\/p\u003e\n\u003cp data-start=\"14524\" data-end=\"14549\"\u003eOur customers benefit from:\u003c\/p\u003e\n\u003cp data-start=\"14551\" data-end=\"14933\"\u003e\u003cstrong data-start=\"14551\" data-end=\"14597\"\u003ea clear evaluation before work begins;\u003c\/strong\u003e\u003cbr data-start=\"14597\" data-end=\"14600\"\u003e\u003cstrong data-start=\"14600\" data-end=\"14645\"\u003ea recommendation adapted to the building;\u003c\/strong\u003e\u003cbr data-start=\"14645\" data-end=\"14648\"\u003e\u003cstrong data-start=\"14648\" data-end=\"14705\"\u003einstallation compliant with technical requirements;\u003c\/strong\u003e\u003cbr data-start=\"14705\" data-end=\"14708\"\u003e\u003cstrong data-start=\"14708\" data-end=\"14764\"\u003ean honest explanation of winter performance;\u003c\/strong\u003e\u003cbr data-start=\"14764\" data-end=\"14767\"\u003e\u003cstrong data-start=\"14767\" data-end=\"14810\"\u003esupport for warranties;\u003c\/strong\u003e\u003cbr data-start=\"14810\" data-end=\"14813\"\u003e\u003cstrong data-start=\"14813\" data-end=\"14852\"\u003ea structured after-sales service;\u003c\/strong\u003e\u003cbr data-start=\"14852\" data-end=\"14855\"\u003e\u003cstrong data-start=\"14855\" data-end=\"14933\"\u003ea team specialized in wall-mounted, central, and multi-zone heat pumps.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"14935\" data-end=\"15181\"\u003eWe know that a heat pump is a significant investment. Our goal is for every customer to understand what they are buying, how the device will operate, and what conditions must be met to achieve a lasting result.\u003c\/p\u003e\n\u003ch2 data-start=\"15183\" data-end=\"15261\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"15186\" data-end=\"15261\"\u003eA compact, efficient HVAC solution well suited for small spaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"15263\" data-end=\"15634\"\u003eThe \u003cstrong data-start=\"15266\" data-end=\"15305\"\u003eZephyr ZE-09DB25 Wall-Mounted Heat Pump\u003c\/strong\u003e is an interesting option for customers looking for a \u003cstrong data-start=\"15393\" data-end=\"15406\"\u003e9,000 BTU\u003c\/strong\u003e wall-mounted heat pump, operating on \u003cstrong data-start=\"15424\" data-end=\"15433\"\u003eR454B\u003c\/strong\u003e, with a \u003cstrong data-start=\"15457\" data-end=\"15466\"\u003e115 V\u003c\/strong\u003e power supply, an \u003cstrong data-start=\"15486\" data-end=\"15506\"\u003eEnergy Star V6.1\u003c\/strong\u003e certification, a low indoor noise level down to \u003cstrong data-start=\"15547\" data-end=\"15559\"\u003e32 dB(A)\u003c\/strong\u003e in silent mode, and a heating capacity suited for Quebec winters.\u003c\/p\u003e\n\u003cp data-start=\"15636\" data-end=\"15951\"\u003eIt is especially suitable for targeted rooms where you want to improve comfort without installing a central system. Its inverter technology, 4D mode, silent mode, night mode, automatic defrost, and heating up to \u003cstrong data-start=\"15877\" data-end=\"15887\"\u003e-30 °C\u003c\/strong\u003e make it a complete machine for serious residential use.\u003c\/p\u003e\n\u003cp data-start=\"15953\" data-end=\"16258\"\u003eTo get a clear quote, check if this model suits your building or compare the Zephyr ZE-09DB25 with other available wall-mounted heat pumps, contact AirGreen. Our team can guide you to the right HVAC solution based on your space, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665925882148,"sku":"ZE-09DB25I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRCB25R454BGRANDMONTREAL.png?v=1783695929"},{"product_id":"thermopompe-murale-zephyr-cb25-r454b-12000-btu-115v","title":"ZEPHYR CB25 R454B Wall Heat Pump | 12000 BTU 115V","description":"\u003ch1 data-start=\"126\" data-end=\"253\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"128\" data-end=\"253\"\u003eZephyr ZE-12DB25 12,000 BTU Wall-Mounted Heat Pump: a powerful, compact 115 V solution adapted to Quebec winters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"255\" data-end=\"851\"\u003eThe \u003cstrong data-start=\"258\" data-end=\"308\"\u003eZephyr ZE-12DB25 12,000 BTU Wall-Mounted Heat Pump\u003c\/strong\u003e is aimed at homeowners seeking a reliable, efficient HVAC solution well suited to Quebec’s climate realities. With its \u003cstrong data-start=\"458\" data-end=\"472\"\u003e12,000 BTU\u003c\/strong\u003e capacity, operation on \u003cstrong data-start=\"496\" data-end=\"517\"\u003eR454B refrigerant\u003c\/strong\u003e, \u003cstrong data-start=\"539\" data-end=\"548\"\u003e115 V\u003c\/strong\u003e power supply, \u003cstrong data-start=\"567\" data-end=\"587\"\u003eEnergy Star V6.1\u003c\/strong\u003e certification, and heating capacity down to \u003cstrong data-start=\"624\" data-end=\"634\"\u003e-30 °C\u003c\/strong\u003e, this model is a very attractive option for cooling and heating a main room, condo, office, bedroom, basement, or residential area where comfort is hard to maintain.\u003c\/p\u003e\n\u003cp data-start=\"853\" data-end=\"1279\"\u003eAt AirGreen, we recommend this type of unit when a customer is looking for a balanced wall-mounted heat pump: powerful enough to provide real comfort, but not unnecessarily oversized for a medium-sized room. The \u003cstrong data-start=\"1087\" data-end=\"1107\"\u003eZephyr ZE-12DB25\u003c\/strong\u003e is particularly interesting because it operates on \u003cstrong data-start=\"1170\" data-end=\"1179\"\u003e115 V\u003c\/strong\u003e, which can simplify some projects when the building’s electrical setup allows.\u003c\/p\u003e\n\u003cp data-start=\"1281\" data-end=\"1724\"\u003eHowever, this model should not be chosen solely because it is compact or has good numbers on paper. A wall-mounted heat pump should always be selected based on the area, insulation, ceiling height, window orientation, air circulation, indoor unit location, outdoor unit position, drainage, piping length, and available electrical capacity.\u003c\/p\u003e\n\u003cp data-start=\"1726\" data-end=\"2009\"\u003eThe Zephyr CB25 R454B brochure provides the technical data for the \u003cstrong data-start=\"1797\" data-end=\"1810\"\u003eZE-12DB25\u003c\/strong\u003e model, including its capacity, efficiency ratings, operating ranges, dimensions, piping, noise levels, and main comfort features.\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2013\" data-end=\"2043\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"2764\" data-end=\"2811\"\u003eGeneral overview of the Zephyr ZE-12DB25\u003c\/h2\u003e\n\u003cp data-start=\"2813\" data-end=\"3180\"\u003eThe \u003cstrong data-start=\"2816\" data-end=\"2836\"\u003eZephyr ZE-12DB25\u003c\/strong\u003e is a 12,000 BTU wall-mounted heat pump designed to offer a good balance between summer cooling, winter heating, energy efficiency, and everyday comfort. It is part of the \u003cstrong data-start=\"3042\" data-end=\"3066\"\u003eZephyr CB25 R454B\u003c\/strong\u003e range, a series designed to meet current HVAC performance, reliability, and efficiency needs.\u003c\/p\u003e\n\u003cp data-start=\"3182\" data-end=\"3527\"\u003eFor an owner in Montreal, Laval, Longueuil, on the South Shore or the North Shore, this type of device can suit many situations: a master bedroom, a closed living room, a small condo, a home office, a family room, a house extension, a basement, or an area that stays too hot in summer and too cold in winter.\u003c\/p\u003e\n\u003cp data-start=\"3529\" data-end=\"3966\"\u003eThe main advantage of this machine is its well-balanced profile. It is not a giant heat pump designed to cover a very large open area, but it offers serious capacity for well-targeted spaces. Its operation down to \u003cstrong data-start=\"3781\" data-end=\"3804\"\u003e-30 °C in heating mode\u003c\/strong\u003e is very important for Quebec, especially when the goal is to reduce the use of electric baseboards for a good part of the winter.\u003c\/p\u003e\n\u003cp data-start=\"3968\" data-end=\"4357\"\u003eThe brochure also highlights several practical functions: \u003cstrong data-start=\"4033\" data-end=\"4046\"\u003enight mode\u003c\/strong\u003e, \u003cstrong data-start=\"4048\" data-end=\"4064\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"4066\" data-end=\"4080\"\u003eiFeel mode\u003c\/strong\u003e, \u003cstrong data-start=\"4082\" data-end=\"4102\"\u003equick start\u003c\/strong\u003e, \u003cstrong data-start=\"4104\" data-end=\"4122\"\u003e24-hour timer\u003c\/strong\u003e, \u003cstrong data-start=\"4124\" data-end=\"4135\"\u003e4D mode\u003c\/strong\u003e, \u003cstrong data-start=\"4137\" data-end=\"4164\"\u003eautomatic oscillation\u003c\/strong\u003e, \u003cstrong data-start=\"4166\" data-end=\"4184\"\u003eTurbo function\u003c\/strong\u003e, \u003cstrong data-start=\"4186\" data-end=\"4211\"\u003eautomatic cleaning\u003c\/strong\u003e, \u003cstrong data-start=\"4213\" data-end=\"4238\"\u003eautomatic defrost\u003c\/strong\u003e, and \u003cstrong data-start=\"4242\" data-end=\"4277\"\u003eoutdoor base heating\u003c\/strong\u003e. These features make daily use more pleasant and flexible.\u003c\/p\u003e\n\u003ch2 data-start=\"4359\" data-end=\"4401\"\u003eImportant technical features\u003c\/h2\u003e\n\u003cp data-start=\"4403\" data-end=\"4500\"\u003eFor the \u003cstrong data-start=\"4418\" data-end=\"4438\"\u003eZephyr ZE-12DB25\u003c\/strong\u003e model, the main technical information is as follows:\u003c\/p\u003e\n\u003cp data-start=\"4502\" data-end=\"5878\"\u003e• \u003cstrong data-start=\"4504\" data-end=\"4523\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"4523\" data-end=\"4526\"\u003e• \u003cstrong data-start=\"4528\" data-end=\"4550\"\u003eSeries: CB25 R454B\u003c\/strong\u003e\u003cbr data-start=\"4550\" data-end=\"4553\"\u003e• \u003cstrong data-start=\"4555\" data-end=\"4577\"\u003eModel: ZE-12DB25\u003c\/strong\u003e\u003cbr data-start=\"4577\" data-end=\"4580\"\u003e• \u003cstrong data-start=\"4582\" data-end=\"4611\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"4611\" data-end=\"4614\"\u003e• \u003cstrong data-start=\"4616\" data-end=\"4670\"\u003eCooling capacity at 35 °C: 12,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4670\" data-end=\"4673\"\u003e• \u003cstrong data-start=\"4675\" data-end=\"4724\"\u003eHeating capacity at 8.3 °C: 12,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4724\" data-end=\"4727\"\u003e• \u003cstrong data-start=\"4729\" data-end=\"4745\"\u003eSEER2: 22.0\u003c\/strong\u003e\u003cbr data-start=\"4745\" data-end=\"4748\"\u003e• \u003cstrong data-start=\"4750\" data-end=\"4768\"\u003eHSPF2 IV: 9.5\u003c\/strong\u003e\u003cbr data-start=\"4768\" data-end=\"4771\"\u003e• \u003cstrong data-start=\"4773\" data-end=\"4789\"\u003eEER2: 12.25\u003c\/strong\u003e\u003cbr data-start=\"4789\" data-end=\"4792\"\u003e• \u003cstrong data-start=\"4794\" data-end=\"4827\"\u003eHeating COP at 8.3 °C: 3.40\u003c\/strong\u003e\u003cbr data-start=\"4827\" data-end=\"4830\"\u003e• \u003cstrong data-start=\"4832\" data-end=\"4858\"\u003eEnergy Star V6.1: yes\u003c\/strong\u003e\u003cbr data-start=\"4858\" data-end=\"4861\"\u003e• \u003cstrong data-start=\"4863\" data-end=\"4886\"\u003eRefrigerant: R454B\u003c\/strong\u003e\u003cbr data-start=\"4886\" data-end=\"4889\"\u003e• \u003cstrong data-start=\"4891\" data-end=\"4922\"\u003eAirflow: 253 to 400 CFM\u003c\/strong\u003e\u003cbr data-start=\"4922\" data-end=\"4925\"\u003e• \u003cstrong data-start=\"4927\" data-end=\"4992\"\u003eIndoor sound pressure: 42 \/ 40 \/ 37 \/ 35 \/ 32 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"4992\" data-end=\"4995\"\u003e• \u003cstrong data-start=\"4997\" data-end=\"5042\"\u003eOutdoor sound pressure: 53 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"5042\" data-end=\"5045\"\u003e• \u003cstrong data-start=\"5047\" data-end=\"5082\"\u003eVoltage: 115 V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"5082\" data-end=\"5085\"\u003e• \u003cstrong data-start=\"5087\" data-end=\"5133\"\u003eNominal cooling current: 8.8 A\u003c\/strong\u003e\u003cbr data-start=\"5133\" data-end=\"5136\"\u003e• \u003cstrong data-start=\"5138\" data-end=\"5178\"\u003eNominal heating current: 9.3 A\u003c\/strong\u003e\u003cbr data-start=\"5178\" data-end=\"5181\"\u003e• \u003cstrong data-start=\"5183\" data-end=\"5197\"\u003eMCA: 16 A\u003c\/strong\u003e\u003cbr data-start=\"5197\" data-end=\"5200\"\u003e• \u003cstrong data-start=\"5202\" data-end=\"5216\"\u003eMOP: 20 A\u003c\/strong\u003e\u003cbr data-start=\"5216\" data-end=\"5219\"\u003e• \u003cstrong data-start=\"5221\" data-end=\"5285\"\u003eRequired communication wire: 4\/14 copper multi-strand 600 V\u003c\/strong\u003e\u003cbr data-start=\"5285\" data-end=\"5288\"\u003e• \u003cstrong data-start=\"5290\" data-end=\"5320\"\u003eCompressor: GMCC rotary\u003c\/strong\u003e\u003cbr data-start=\"5320\" data-end=\"5323\"\u003e• \u003cstrong data-start=\"5325\" data-end=\"5356\"\u003eExpansion device: EEV\u003c\/strong\u003e\u003cbr data-start=\"5356\" data-end=\"5359\"\u003e• \u003cstrong data-start=\"5361\" data-end=\"5390\"\u003eIndoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"5390\" data-end=\"5393\"\u003e• \u003cstrong data-start=\"5395\" data-end=\"5424\"\u003eOutdoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"5424\" data-end=\"5427\"\u003e• \u003cstrong data-start=\"5429\" data-end=\"5455\"\u003eLiquid pipe: 1\/4 in\u003c\/strong\u003e\u003cbr data-start=\"5455\" data-end=\"5458\"\u003e• \u003cstrong data-start=\"5460\" data-end=\"5482\"\u003eGas pipe: 3\/8 in\u003c\/strong\u003e\u003cbr data-start=\"5482\" data-end=\"5485\"\u003e• \u003cstrong data-start=\"5487\" data-end=\"5534\"\u003eMinimum-maximum piping length: 10 to 65 ft\u003c\/strong\u003e\u003cbr data-start=\"5534\" data-end=\"5537\"\u003e• \u003cstrong data-start=\"5539\" data-end=\"5573\"\u003eMaximum elevation difference: 50 ft\u003c\/strong\u003e\u003cbr data-start=\"5573\" data-end=\"5576\"\u003e• \u003cstrong data-start=\"5578\" data-end=\"5611\"\u003ePrecharge length: 25 ft\u003c\/strong\u003e\u003cbr data-start=\"5611\" data-end=\"5614\"\u003e• \u003cstrong data-start=\"5616\" data-end=\"5673\"\u003eIndoor unit dimensions: 33.44 x 11.56 x 8.06 in\u003c\/strong\u003e\u003cbr data-start=\"5673\" data-end=\"5676\"\u003e• \u003cstrong data-start=\"5678\" data-end=\"5736\"\u003eOutdoor unit dimensions: 31.88 x 23.00 x 11.00 in\u003c\/strong\u003e\u003cbr data-start=\"5736\" data-end=\"5739\"\u003e• \u003cstrong data-start=\"5741\" data-end=\"5786\"\u003eCooling range: -15 °C to 48 °C\u003c\/strong\u003e\u003cbr data-start=\"5786\" data-end=\"5789\"\u003e• \u003cstrong data-start=\"5791\" data-end=\"5830\"\u003eHeating range: -30 °C to 24 °C\u003c\/strong\u003e\u003cbr data-start=\"5830\" data-end=\"5833\"\u003e• \u003cstrong data-start=\"5835\" data-end=\"5878\"\u003eZephyr Basic Warranty: 10 years parts\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5880\" data-end=\"6121\"\u003eThis data is not just technical details. It directly affects the feasibility of the project, installation cost, actual performance, sound comfort, electrical consumption, and compatibility with the building.\u003c\/p\u003e\n\u003cp data-start=\"6123\" data-end=\"6444\"\u003eA \u003cstrong data-start=\"6142\" data-end=\"6165\"\u003e12,000 BTU heat pump at 115 V\u003c\/strong\u003e is not treated like a more powerful unit at 208\/230 V. Before confirming installation, the electrical circuit, available space, refrigerant line length, drainage, outdoor unit location, and necessary clearances must be checked.\u003c\/p\u003e\n\u003ch2 data-start=\"6446\" data-end=\"6480\"\u003eWhy R454B is relevant\u003c\/h2\u003e\n\u003cp data-start=\"6482\" data-end=\"6823\"\u003eThe \u003cstrong data-start=\"6485\" data-end=\"6505\"\u003eZephyr ZE-12DB25\u003c\/strong\u003e uses the refrigerant \u003cstrong data-start=\"6529\" data-end=\"6538\"\u003eR454B\u003c\/strong\u003e, a next-generation refrigerant increasingly common in modern HVAC systems. For many clients, the type of gas seems secondary, but it plays a real role in the device’s design, installation procedures, and good service practices.\u003c\/p\u003e\n\u003cp data-start=\"6825\" data-end=\"7304\"\u003eR454B represents the market’s shift toward newer solutions better suited to current standards. This requires a serious, clean installation that complies with the manufacturer’s recommendations. At AirGreen, we pay special attention to essential steps: \u003cstrong data-start=\"7118\" data-end=\"7140\"\u003eclean flaring\u003c\/strong\u003e, \u003cstrong data-start=\"7142\" data-end=\"7163\"\u003eleak testing\u003c\/strong\u003e, \u003cstrong data-start=\"7165\" data-end=\"7193\"\u003erigorous vacuuming\u003c\/strong\u003e, \u003cstrong data-start=\"7195\" data-end=\"7234\"\u003eadherence to piping lengths\u003c\/strong\u003e, \u003cstrong data-start=\"7236\" data-end=\"7271\"\u003eproper electrical connection\u003c\/strong\u003e, and \u003cstrong data-start=\"7275\" data-end=\"7303\"\u003ecomplete commissioning\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"7306\" data-end=\"7632\"\u003eA modern device like the Zephyr ZE-12DB25 can provide excellent comfort, but only if installed precisely. Poor installation can lead to reduced performance, abnormal noises, higher consumption, refrigerant leaks, or premature compressor wear.\u003c\/p\u003e\n\u003ch2 data-start=\"7634\" data-end=\"7685\"\u003eA 12,000 BTU heat pump: for which spaces?\u003c\/h2\u003e\n\u003cp data-start=\"7687\" data-end=\"7963\"\u003eA wall-mounted heat pump of \u003cstrong data-start=\"7713\" data-end=\"7727\"\u003e12,000 BTU\u003c\/strong\u003e can suit many residential projects, but it must be properly sized. At AirGreen, we avoid recommending a unit based solely on approximate area. Instead, we analyze the entire context.\u003c\/p\u003e\n\u003cp data-start=\"7965\" data-end=\"8005\"\u003eThe elements to check include:\u003c\/p\u003e\n\u003cp data-start=\"8007\" data-end=\"8406\"\u003e• the actual size of the room;\u003cbr data-start=\"8042\" data-end=\"8045\"\u003e• ceiling height;\u003cbr data-start=\"8071\" data-end=\"8074\"\u003e• the level of insulation;\u003cbr data-start=\"8098\" data-end=\"8101\"\u003e• sun exposure;\u003cbr data-start=\"8126\" data-end=\"8129\"\u003e• the number of windows;\u003cbr data-start=\"8155\" data-end=\"8158\"\u003e• air circulation between rooms;\u003cbr data-start=\"8198\" data-end=\"8201\"\u003e• the presence of stairs or corridors;\u003cbr data-start=\"8243\" data-end=\"8246\"\u003e• the use of the room;\u003cbr data-start=\"8268\" data-end=\"8271\"\u003e• heating needs in winter;\u003cbr data-start=\"8306\" data-end=\"8309\"\u003e• the expected level of comfort;\u003cbr data-start=\"8340\" data-end=\"8343\"\u003e• the possibility of installing the indoor unit in the right place.\u003c\/p\u003e\n\u003cp data-start=\"8408\" data-end=\"8836\"\u003eIn a condo in Montreal, a \u003cstrong data-start=\"8438\" data-end=\"8458\"\u003eZephyr ZE-12DB25\u003c\/strong\u003e can be an excellent choice for a main living area if the space is open. In a house in Laval, it can suit a large bedroom, an office, or a family room. On the South Shore or North Shore, it can be used in a basement, an extension, a room above a garage, or a space that remains uncomfortable despite the main system.\u003c\/p\u003e\n\u003cp data-start=\"8838\" data-end=\"9235\"\u003e\u003cstrong data-start=\"8838\" data-end=\"8879\"\u003eProper sizing is essential.\u003c\/strong\u003e A unit that is too small will run too long and struggle during extreme periods. A unit that is too powerful can reach the temperature too quickly in cooling mode, reduce dehumidification, and create uneven comfort. The \u003cstrong data-start=\"9139\" data-end=\"9153\"\u003e12,000 BTU\u003c\/strong\u003e model is often an excellent compromise, but it must be confirmed based on the building.\u003c\/p\u003e\n\u003ch2 data-start=\"9237\" data-end=\"9279\"\u003eHeating performance down to -30 °C\u003c\/h2\u003e\n\u003cp data-start=\"9281\" data-end=\"9631\"\u003eThe brochure states that the Zephyr can heat down to an outside temperature of \u003cstrong data-start=\"9367\" data-end=\"9377\"\u003e-30 °C\u003c\/strong\u003e. For Quebec, this is a very important point. It means the unit is designed to keep working during extreme cold, which can reduce the use of traditional electric heating for much of the winter.\u003c\/p\u003e\n\u003cp data-start=\"9633\" data-end=\"9721\"\u003eFor the \u003cstrong data-start=\"9641\" data-end=\"9654\"\u003eZE-12DB25\u003c\/strong\u003e, the low-temperature heating data are as follows:\u003c\/p\u003e\n\u003cp data-start=\"9723\" data-end=\"9944\"\u003e• \u003cstrong data-start=\"9725\" data-end=\"9770\"\u003eNominal capacity at -8.3 °C: 9,300 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"9770\" data-end=\"9773\"\u003e• \u003cstrong data-start=\"9775\" data-end=\"9819\"\u003eMaximum capacity at -15 °C: 9,200 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"9819\" data-end=\"9822\"\u003e• \u003cstrong data-start=\"9824\" data-end=\"9846\"\u003eCOP at -15 °C: 1.9\u003c\/strong\u003e\u003cbr data-start=\"9846\" data-end=\"9849\"\u003e• \u003cstrong data-start=\"9851\" data-end=\"9895\"\u003eMaximum capacity at -20 °C: 6,900 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"9895\" data-end=\"9898\"\u003e• \u003cstrong data-start=\"9900\" data-end=\"9944\"\u003eMaximum capacity at -25 °C: 5,900 BTU\/h\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"9946\" data-end=\"10364\"\u003eThese figures must be well understood. A heat pump can operate down to \u003cstrong data-start=\"10027\" data-end=\"10037\"\u003e-30 °C\u003c\/strong\u003e, but its heating capacity decreases as the outside temperature drops. In a well-insulated house, the ZE-12DB25 can cover a good portion of the needs of a targeted area. In an older house, with many windows or exposed to wind, supplementary heating may still be necessary on the coldest days.\u003c\/p\u003e\n\u003cp data-start=\"10366\" data-end=\"10594\"\u003eAt AirGreen, we always explain this point clearly. \u003cstrong data-start=\"10427\" data-end=\"10594\"\u003eA wall-mounted heat pump is not just an air conditioning device: it is also an effective heating tool when properly chosen and used.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"10596\" data-end=\"10665\"\u003eIndoor comfort: 4D mode, silence, iFeel, and practical functions\u003c\/h2\u003e\n\u003cp data-start=\"10667\" data-end=\"10882\"\u003eThe Zephyr ZE-12DB25 offers several functions designed to improve daily comfort. The brochure notably highlights the \u003cstrong data-start=\"10800\" data-end=\"10811\"\u003e4D mode\u003c\/strong\u003e, \u003cstrong data-start=\"10815\" data-end=\"10842\"\u003eautomatic oscillation\u003c\/strong\u003e, and variable frequency technology.\u003c\/p\u003e\n\u003cp data-start=\"10884\" data-end=\"11208\"\u003eThe \u003cstrong data-start=\"10887\" data-end=\"10898\"\u003e4D mode\u003c\/strong\u003e allows better air distribution in the room. The air does not just come out in one direction: it is better spread, which helps limit cold or hot spots. In a living room, this can make a real difference, especially if occupants often sit in the same place.\u003c\/p\u003e\n\u003cp data-start=\"11210\" data-end=\"11533\"\u003eThe \u003cstrong data-start=\"11213\" data-end=\"11227\"\u003eiFeel mode\u003c\/strong\u003e is also interesting. This function allows the remote control to help read the temperature around the user. In practice, this can improve perceived comfort, as the device adjusts its operation according to a temperature closer to where the occupants are located.\u003c\/p\u003e\n\u003cp data-start=\"11535\" data-end=\"11564\"\u003eThe brochure also mentions:\u003c\/p\u003e\n\u003cp data-start=\"11566\" data-end=\"11924\"\u003e• \u003cstrong data-start=\"11568\" data-end=\"11581\"\u003enight mode\u003c\/strong\u003e;\u003cbr data-start=\"11582\" data-end=\"11585\"\u003e• \u003cstrong data-start=\"11587\" data-end=\"11603\"\u003esilent mode\u003c\/strong\u003e;\u003cbr data-start=\"11604\" data-end=\"11607\"\u003e• \u003cstrong data-start=\"11609\" data-end=\"11629\"\u003equick start\u003c\/strong\u003e;\u003cbr data-start=\"11630\" data-end=\"11633\"\u003e• \u003cstrong data-start=\"11635\" data-end=\"11653\"\u003e24-hour timer\u003c\/strong\u003e;\u003cbr data-start=\"11654\" data-end=\"11657\"\u003e• \u003cstrong data-start=\"11659\" data-end=\"11699\"\u003e5 indoor fan speeds\u003c\/strong\u003e;\u003cbr data-start=\"11700\" data-end=\"11703\"\u003e• \u003cstrong data-start=\"11705\" data-end=\"11734\"\u003eLED wireless remote control\u003c\/strong\u003e;\u003cbr data-start=\"11735\" data-end=\"11738\"\u003e• \u003cstrong data-start=\"11740\" data-end=\"11758\"\u003eTurbo function\u003c\/strong\u003e;\u003cbr data-start=\"11759\" data-end=\"11762\"\u003e• \u003cstrong data-start=\"11764\" data-end=\"11783\"\u003eLED dimmer\u003c\/strong\u003e;\u003cbr data-start=\"11784\" data-end=\"11787\"\u003e• \u003cstrong data-start=\"11789\" data-end=\"11825\"\u003ediffuser position memory\u003c\/strong\u003e;\u003cbr data-start=\"11826\" data-end=\"11829\"\u003e• \u003cstrong data-start=\"11831\" data-end=\"11861\"\u003eautomatic 8 °C heating\u003c\/strong\u003e;\u003cbr data-start=\"11862\" data-end=\"11865\"\u003e• \u003cstrong data-start=\"11867\" data-end=\"11892\"\u003eautomatic cleaning\u003c\/strong\u003e;\u003cbr data-start=\"11893\" data-end=\"11896\"\u003e• \u003cstrong data-start=\"11898\" data-end=\"11923\"\u003eautomatic defrost\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"11926\" data-end=\"12254\"\u003eThese functions make use simpler and more comfortable. For example, the \u003cstrong data-start=\"12011\" data-end=\"12027\"\u003esilent mode\u003c\/strong\u003e can be useful in a bedroom or office. The \u003cstrong data-start=\"12078\" data-end=\"12091\"\u003enight mode\u003c\/strong\u003e helps maintain a comfortable temperature during sleep. The \u003cstrong data-start=\"12157\" data-end=\"12175\"\u003eTurbo function\u003c\/strong\u003e can be handy when you want to quickly cool or heat a room.\u003c\/p\u003e\n\u003ch2 data-start=\"12256\" data-end=\"12313\"\u003eHVAC installation: the details that make the difference\u003c\/h2\u003e\n\u003cp data-start=\"12315\" data-end=\"12502\"\u003eA good wall-mounted heat pump installation is not just about mounting the unit on the wall. To achieve a durable, efficient, and aesthetic result, every detail must be planned.\u003c\/p\u003e\n\u003cp data-start=\"12504\" data-end=\"12545\"\u003eAt AirGreen, we specifically check:\u003c\/p\u003e\n\u003cp data-start=\"12547\" data-end=\"12947\"\u003e• indoor unit location;\u003cbr data-start=\"12585\" data-end=\"12588\"\u003e• airflow direction;\u003cbr data-start=\"12616\" data-end=\"12619\"\u003e• distance to the outdoor unit;\u003cbr data-start=\"12660\" data-end=\"12663\"\u003e• piping route;\u003cbr data-start=\"12694\" data-end=\"12697\"\u003e• condensation drainage;\u003cbr data-start=\"12727\" data-end=\"12730\"\u003e• wall structure;\u003cbr data-start=\"12752\" data-end=\"12755\"\u003e• electrical access;\u003cbr data-start=\"12776\" data-end=\"12779\"\u003e• circuit protection;\u003cbr data-start=\"12806\" data-end=\"12809\"\u003e• clearances around the outdoor unit;\u003cbr data-start=\"12856\" data-end=\"12859\"\u003e• outdoor installation height for winter;\u003cbr data-start=\"12911\" data-end=\"12914\"\u003e• future access for maintenance.\u003c\/p\u003e\n\u003cp data-start=\"12949\" data-end=\"13272\"\u003eFor a \u003cstrong data-start=\"12958\" data-end=\"12978\"\u003eZephyr ZE-12DB25\u003c\/strong\u003e, the indicated outdoor noise level is \u003cstrong data-start=\"13022\" data-end=\"13034\"\u003e53 dB(A)\u003c\/strong\u003e, which is reasonable for a wall-mounted heat pump. Despite this, the location of the outdoor unit must be chosen carefully, especially in denser areas of Montreal, Longueuil, or Laval, where neighbors may be close.\u003c\/p\u003e\n\u003cp data-start=\"13274\" data-end=\"13581\"\u003eThe outdoor unit must also be protected against snow accumulation, ice falls, roof water, and obstacles that could hinder air circulation. A poorly planned outdoor installation can reduce performance, increase defrost cycles, or complicate maintenance.\u003c\/p\u003e\n\u003ch2 data-start=\"13583\" data-end=\"13635\"\u003e115 V power supply: an important point to verify\u003c\/h2\u003e\n\u003cp data-start=\"13637\" data-end=\"13919\"\u003eOne of the important points of the \u003cstrong data-start=\"13668\" data-end=\"13681\"\u003eZE-12DB25\u003c\/strong\u003e is its \u003cstrong data-start=\"13706\" data-end=\"13715\"\u003e115 V\u003c\/strong\u003e power supply. This can be an advantage in some projects, as this type of power supply can sometimes facilitate the integration of the device in buildings where adding a 208\/230 V circuit would be more complex.\u003c\/p\u003e\n\u003cp data-start=\"13921\" data-end=\"14264\"\u003eHowever, this does not mean that the electrical installation should be taken lightly. The brochure specifies a \u003cstrong data-start=\"14036\" data-end=\"14051\"\u003eMCA of 16 A\u003c\/strong\u003e and a \u003cstrong data-start=\"14058\" data-end=\"14073\"\u003eMOP of 20 A\u003c\/strong\u003e. These values must be respected. The electrical panel must be checked, the circuit must be appropriate, and the installed components must meet the device's requirements.\u003c\/p\u003e\n\u003cp data-start=\"14266\" data-end=\"14488\"\u003e\u003cstrong data-start=\"14266\" data-end=\"14365\"\u003eThe fact that a device is 115 V does not mean it can be plugged in just any way.\u003c\/strong\u003e A serious HVAC installation requires a complete check of the circuit, breaker, wiring, and compliance.\u003c\/p\u003e\n\u003cp data-start=\"14490\" data-end=\"14846\"\u003eIn many older homes in Greater Montreal, this step is essential. Some panels are already charged, some circuits have been modified over the years, and some existing installations are not suitable for a modern heat pump. At AirGreen, we prefer to verify these points before work to avoid surprises.\u003c\/p\u003e\n\u003ch2 data-start=\"14848\" data-end=\"14888\"\u003ePiping, dimensions, and location\u003c\/h2\u003e\n\u003cp data-start=\"14890\" data-end=\"15177\"\u003eThe \u003cstrong data-start=\"14893\" data-end=\"14913\"\u003eZephyr ZE-12DB25\u003c\/strong\u003e uses refrigerant piping of \u003cstrong data-start=\"14953\" data-end=\"14979\"\u003e1\/4 in for liquid\u003c\/strong\u003e and \u003cstrong data-start=\"14983\" data-end=\"15005\"\u003e3\/8 in for gas\u003c\/strong\u003e. The total allowed piping length is \u003cstrong data-start=\"15055\" data-end=\"15072\"\u003e10 to 65 feet\u003c\/strong\u003e, with a maximum elevation difference of \u003cstrong data-start=\"15109\" data-end=\"15121\"\u003e50 feet\u003c\/strong\u003e. The indicated precharge length is \u003cstrong data-start=\"15164\" data-end=\"15176\"\u003e25 feet\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"15179\" data-end=\"15389\"\u003eThis information is important during a new installation but also when replacing. If a customer wants to replace an old heat pump and reuse the existing lines, it is necessary to check:\u003c\/p\u003e\n\u003cp data-start=\"15391\" data-end=\"15634\"\u003e• the diameter of the existing pipes;\u003cbr data-start=\"15426\" data-end=\"15429\"\u003e• the condition of the piping;\u003cbr data-start=\"15455\" data-end=\"15458\"\u003e• the old refrigerant used;\u003cbr data-start=\"15489\" data-end=\"15492\"\u003e• the length of the run;\u003cbr data-start=\"15518\" data-end=\"15521\"\u003e• accessibility;\u003cbr data-start=\"15539\" data-end=\"15542\"\u003e• the presence of kinks or damage;\u003cbr data-start=\"15579\" data-end=\"15582\"\u003e• the possibility of properly replacing the lines.\u003c\/p\u003e\n\u003cp data-start=\"15636\" data-end=\"15829\"\u003e\u003cstrong data-start=\"15636\" data-end=\"15709\"\u003eNever assume that old lines are compatible.\u003c\/strong\u003e Poor piping matching can harm performance, affect reliability, and complicate the warranty.\u003c\/p\u003e\n\u003cp data-start=\"15831\" data-end=\"16159\"\u003eThe indoor unit dimensions are approximately \u003cstrong data-start=\"15883\" data-end=\"15910\"\u003e33.44 x 11.56 x 8.06 in\u003c\/strong\u003e. This makes it a relatively compact unit for a 12,000 BTU. The outdoor unit measures about \u003cstrong data-start=\"16012\" data-end=\"16040\"\u003e31.88 x 23.00 x 11.00 in\u003c\/strong\u003e. These dimensions must be considered for aesthetics, clearance, airflow, and future access.\u003c\/p\u003e\n\u003ch2 data-start=\"16161\" data-end=\"16187\"\u003eMaintenance and durability\u003c\/h2\u003e\n\u003cp data-start=\"16189\" data-end=\"16421\"\u003eA well-installed wall-mounted heat pump must also be well maintained. Even though the Zephyr ZE-12DB25 offers features like \u003cstrong data-start=\"16319\" data-end=\"16344\"\u003eautomatic cleaning\u003c\/strong\u003e and \u003cstrong data-start=\"16351\" data-end=\"16376\"\u003eautomatic defrosting\u003c\/strong\u003e, this does not replace regular maintenance.\u003c\/p\u003e\n\u003cp data-start=\"16423\" data-end=\"16452\"\u003eWe specifically recommend:\u003c\/p\u003e\n\u003cp data-start=\"16454\" data-end=\"16924\"\u003e• clean filters regularly;\u003cbr data-start=\"16491\" data-end=\"16494\"\u003e• ensure the condensation drain remains clear;\u003cbr data-start=\"16547\" data-end=\"16550\"\u003e• keep the outdoor unit free of leaves, dust, snow, and debris;\u003cbr data-start=\"16624\" data-end=\"16627\"\u003e• monitor unusual noises;\u003cbr data-start=\"16663\" data-end=\"16666\"\u003e• check performance before extreme weather periods;\u003cbr data-start=\"16720\" data-end=\"16723\"\u003e• have the device inspected if heating or cooling seems less effective;\u003cbr data-start=\"16810\" data-end=\"16813\"\u003e• schedule professional cleaning when the indoor unit accumulates dust or mold.\u003c\/p\u003e\n\u003cp data-start=\"16926\" data-end=\"17138\"\u003eProper maintenance helps maintain comfort, air quality, energy efficiency, and system lifespan. It also allows for early detection of problems before they become costly.\u003c\/p\u003e\n\u003ch2 data-start=\"17140\" data-end=\"17180\"\u003eMistakes to avoid before installation\u003c\/h2\u003e\n\u003cp data-start=\"17182\" data-end=\"17344\"\u003eIn our experience, the most frequent mistakes don’t always come from the brand choice. They often come from a poor project assessment.\u003c\/p\u003e\n\u003cp data-start=\"17346\" data-end=\"17374\"\u003eHere are the mistakes to avoid:\u003c\/p\u003e\n\u003cp data-start=\"17376\" data-end=\"17883\"\u003e• choosing a 12,000 BTU heat pump without analyzing the room;\u003cbr data-start=\"17436\" data-end=\"17439\"\u003e• installing the indoor unit in a location that poorly distributes air;\u003cbr data-start=\"17507\" data-end=\"17510\"\u003e• neglecting drainage;\u003cbr data-start=\"17533\" data-end=\"17536\"\u003e• forgetting the electrical inspection;\u003cbr data-start=\"17573\" data-end=\"17576\"\u003e• assuming old refrigerant lines are compatible;\u003cbr data-start=\"17643\" data-end=\"17646\"\u003e• placing the outdoor unit too close to a wall or fence;\u003cbr data-start=\"17710\" data-end=\"17713\"\u003e• ignoring snow accumulation;\u003cbr data-start=\"17747\" data-end=\"17750\"\u003e• choosing the device based only on price;\u003cbr data-start=\"17795\" data-end=\"17798\"\u003e• not considering outdoor noise;\u003cbr data-start=\"17839\" data-end=\"17842\"\u003e• forgetting future access for maintenance.\u003c\/p\u003e\n\u003cp data-start=\"17885\" data-end=\"18052\"\u003e\u003cstrong data-start=\"17885\" data-end=\"18052\"\u003eA good heat pump poorly installed will deliver average results. A well-chosen and well-installed heat pump can completely transform the comfort of a room.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"18054\" data-end=\"18296\"\u003eThat’s why AirGreen takes the time to analyze the building before recommending a model. Our goal is not just to install a machine but to offer a durable, efficient HVAC solution adapted to the client’s reality.\u003c\/p\u003e\n\u003ch2 data-start=\"18298\" data-end=\"18361\"\u003eWhy choose AirGreen to install the Zephyr ZE-12DB25\u003c\/h2\u003e\n\u003cp data-start=\"18363\" data-end=\"18754\"\u003eAirGreen installs, maintains, and repairs HVAC systems throughout Greater Montreal, including \u003cstrong data-start=\"18459\" data-end=\"18518\"\u003eMontreal, Laval, Longueuil, the South Shore, and the North Shore\u003c\/strong\u003e. Our team understands the challenges of Quebec buildings: old houses, condos, multiplexes, modern homes with large windows, basements, hard-to-heat spaces, overloaded electrical panels, and winter installation constraints.\u003c\/p\u003e\n\u003cp data-start=\"18756\" data-end=\"18851\"\u003eBy choosing AirGreen for the installation of the \u003cstrong data-start=\"18806\" data-end=\"18826\"\u003eZephyr ZE-12DB25\u003c\/strong\u003e, customers benefit from:\u003c\/p\u003e\n\u003cp data-start=\"18853\" data-end=\"19344\"\u003e• a clear assessment before the work;\u003cbr data-start=\"18897\" data-end=\"18900\"\u003e• a recommendation tailored to the room;\u003cbr data-start=\"18942\" data-end=\"18945\"\u003e• an installation compliant with HVAC requirements;\u003cbr data-start=\"18994\" data-end=\"18997\"\u003e• a thorough electrical inspection;\u003cbr data-start=\"19038\" data-end=\"19041\"\u003e• special attention to the location of the indoor unit;\u003cbr data-start=\"19110\" data-end=\"19113\"\u003e• outdoor installation designed for Quebec winters;\u003cbr data-start=\"19175\" data-end=\"19178\"\u003e• honest explanation of low-temperature performance;\u003cbr data-start=\"19243\" data-end=\"19246\"\u003e• support after installation;\u003cbr data-start=\"19289\" data-end=\"19292\"\u003e• professional service in Greater Montreal.\u003c\/p\u003e\n\u003cp data-start=\"19346\" data-end=\"19635\"\u003eWe know a heat pump is a significant investment. Our role is to help the customer understand what they are buying, why this model may be appropriate, its limitations, how it should be installed, and how to use it to achieve the best possible performance.\u003c\/p\u003e\n\u003ch2 data-start=\"19637\" data-end=\"19650\"\u003eConclusion\u003c\/h2\u003e\n\u003cp data-start=\"19652\" data-end=\"20165\"\u003eThe \u003cstrong data-start=\"19655\" data-end=\"19705\"\u003eZephyr ZE-12DB25 12,000 BTU Wall-Mounted Heat Pump\u003c\/strong\u003e is an interesting HVAC solution for homeowners looking for a compact, efficient, modern unit capable of operating in Quebec’s winter conditions. With its \u003cstrong data-start=\"19896\" data-end=\"19917\"\u003eR454B refrigerant\u003c\/strong\u003e, \u003cstrong data-start=\"19923\" data-end=\"19940\"\u003eSEER2 of 22.0\u003c\/strong\u003e, \u003cstrong data-start=\"19959\" data-end=\"19979\"\u003eEnergy Star V6.1 certification\u003c\/strong\u003e, \u003cstrong data-start=\"20003\" data-end=\"20012\"\u003e115 V operation\u003c\/strong\u003e, heating down to \u003cstrong data-start=\"20036\" data-end=\"20046\"\u003e-30 °C\u003c\/strong\u003e, and many comfort features, it stands as a serious choice for many residential projects.\u003c\/p\u003e\n\u003cp data-start=\"20167\" data-end=\"20585\"\u003eIt is particularly suitable for medium-sized rooms, condos, offices, bedrooms, basements, and areas where you want to improve comfort without installing a central system. Its outdoor noise level of \u003cstrong data-start=\"20398\" data-end=\"20410\"\u003e53 dB(A)\u003c\/strong\u003e, air flow of \u003cstrong data-start=\"20431\" data-end=\"20448\"\u003e253 to 400 CFM\u003c\/strong\u003e, GMCC rotary compressor, and indoor and outdoor DC motors make it a well-equipped unit for daily use.\u003c\/p\u003e\n\u003cp data-start=\"20587\" data-end=\"20860\"\u003eHowever, as with any wall-mounted heat pump, actual performance will depend on the installation. The choice of location, \u003cstrong data-start=\"20726\" data-end=\"20742\"\u003e1\/4 - 3\/8 inch\u003c\/strong\u003e piping, \u003cstrong data-start=\"20766\" data-end=\"20775\"\u003e115 V\u003c\/strong\u003e electrical circuit, drainage, clearances, and commissioning must be done correctly.\u003c\/p\u003e\n\u003cp data-start=\"20862\" data-end=\"21186\"\u003eTo get a clear quote, compare the \u003cstrong data-start=\"20910\" data-end=\"20930\"\u003eZephyr ZE-12DB25\u003c\/strong\u003e with other models or plan an installation in Montreal, Laval, Longueuil, on the South Shore or the North Shore, contact AirGreen. Our team will help you choose an HVAC solution suited to your building, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665925980452,"sku":"ZE-12DB25I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRCB25R454BGRANDMONTREAL_0ce0db7a-7df9-4987-ac18-2057feabb37a.png?v=1783695924"},{"product_id":"thermopompe-murale-zephyr-cb25-r454b-9000-btu-montreal-laval-rive-sud","title":"ZEPHYR CB25 R454B Wall Heat Pump | 9000 BTU | Montreal, Laval, South Shore","description":"\u003ch1 data-start=\"0\" data-end=\"116\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2\" data-end=\"116\"\u003eZephyr CB25 R454B Wall-Mounted Heat Pump ZE-09CB25 – 9,000 BTU, high efficiency and reliable comfort down to -30 °C\u003c\/strong\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"118\" data-end=\"642\"\u003eThe \u003cstrong data-start=\"121\" data-end=\"171\"\u003eZephyr CB25 R454B Wall-Mounted Heat Pump ZE-09CB25\u003c\/strong\u003e is a compact, efficient HVAC solution well suited for residential spaces requiring stable comfort year-round. With its \u003cstrong data-start=\"321\" data-end=\"334\"\u003e9,000 BTU\u003c\/strong\u003e capacity, energy efficiency up to \u003cstrong data-start=\"377\" data-end=\"391\"\u003e25.0 SEER2\u003c\/strong\u003e, and operation with \u003cstrong data-start=\"417\" data-end=\"438\"\u003eR454B refrigerant\u003c\/strong\u003e, this model is especially aimed at owners who want to cool and heat a bedroom, office, condo, small living area, extension, or a room that is difficult to balance.\u003c\/p\u003e\n\u003cp data-start=\"644\" data-end=\"1185\"\u003eAt AirGreen, we recommend this type of wall-mounted heat pump when the customer is looking for a discreet, efficient, and properly sized solution for the realities of the Quebec climate. In Montreal, Laval, Longueuil, on the South Shore and North Shore, needs often vary greatly from one building to another: insulation, window orientation, ceiling height, available exterior walls, desired noise level, access to the electrical panel, and installation constraints must be evaluated before confirming the final choice.\u003c\/p\u003e\n\u003cp data-start=\"1187\" data-end=\"1574\"\u003eThe \u003cstrong data-start=\"1197\" data-end=\"1210\"\u003eZE-09CB25\u003c\/strong\u003e model stands out with several key features: \u003cstrong data-start=\"1260\" data-end=\"1288\"\u003eheating down to -30 °C\u003c\/strong\u003e, \u003cstrong data-start=\"1290\" data-end=\"1322\"\u003ecooling down to -15 °C\u003c\/strong\u003e, \u003cstrong data-start=\"1324\" data-end=\"1360\"\u003evariable frequency technology\u003c\/strong\u003e, \u003cstrong data-start=\"1362\" data-end=\"1373\"\u003e4D mode\u003c\/strong\u003e, \u003cstrong data-start=\"1375\" data-end=\"1407\"\u003eairflow from 253 to 383 CFM\u003c\/strong\u003e, \u003cstrong data-start=\"1409\" data-end=\"1451\"\u003eoutdoor sound pressure of 53 dB(A)\u003c\/strong\u003e, and a \u003cstrong data-start=\"1455\" data-end=\"1507\"\u003eZephyr basic 10-year parts warranty\u003c\/strong\u003e according to the technical brochure.\u003c\/p\u003e\n\u003ch2 data-start=\"2144\" data-end=\"2194\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2147\" data-end=\"2194\"\u003e1. Introduction to the Zephyr CB25 ZE-09CB25\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2196\" data-end=\"2619\"\u003eThe \u003cstrong data-start=\"2199\" data-end=\"2224\"\u003eZephyr CB25 ZE-09CB25\u003c\/strong\u003e is a wall-mounted heat pump with \u003cstrong data-start=\"2255\" data-end=\"2268\"\u003e9,000 BTU\u003c\/strong\u003e designed to provide precise comfort in small to medium-sized spaces. Unlike an overly powerful unit that could cause short cycling, poor dehumidification, or uneven air sensation, a well-selected 9,000 BTU heat pump can offer an excellent balance of performance, efficiency, and comfort.\u003c\/p\u003e\n\u003cp data-start=\"2621\" data-end=\"2670\"\u003eThis model is particularly suitable for:\u003c\/p\u003e\n\u003cp data-start=\"2672\" data-end=\"2957\"\u003e\u003cstrong data-start=\"2672\" data-end=\"2698\"\u003ea master bedroom\u003c\/strong\u003e,\u003cbr data-start=\"2699\" data-end=\"2702\"\u003e\u003cstrong data-start=\"2702\" data-end=\"2726\"\u003ea home office\u003c\/strong\u003e,\u003cbr data-start=\"2727\" data-end=\"2730\"\u003e\u003cstrong data-start=\"2730\" data-end=\"2742\"\u003ea condo\u003c\/strong\u003e,\u003cbr data-start=\"2743\" data-end=\"2746\"\u003e\u003cstrong data-start=\"2746\" data-end=\"2781\"\u003ea room above a garage\u003c\/strong\u003e,\u003cbr data-start=\"2782\" data-end=\"2785\"\u003e\u003cstrong data-start=\"2785\" data-end=\"2821\"\u003ea partially open basement\u003c\/strong\u003e,\u003cbr data-start=\"2822\" data-end=\"2825\"\u003e\u003cstrong data-start=\"2825\" data-end=\"2851\"\u003ea small living area\u003c\/strong\u003e,\u003cbr data-start=\"2852\" data-end=\"2855\"\u003e\u003cstrong data-start=\"2855\" data-end=\"2887\"\u003ea renovated, better-insulated space\u003c\/strong\u003e,\u003cbr data-start=\"2888\" data-end=\"2891\"\u003e\u003cstrong data-start=\"2891\" data-end=\"2956\"\u003ea home where the comfort of a single zone needs to be improved\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"2959\" data-end=\"3349\"\u003eThe Zephyr CB25 brochure emphasizes reliable daily use, with several features designed for comfort: \u003cstrong data-start=\"3088\" data-end=\"3101\"\u003enight mode\u003c\/strong\u003e, \u003cstrong data-start=\"3103\" data-end=\"3119\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"3121\" data-end=\"3135\"\u003eiFeel mode\u003c\/strong\u003e, \u003cstrong data-start=\"3137\" data-end=\"3157\"\u003equick start\u003c\/strong\u003e, \u003cstrong data-start=\"3159\" data-end=\"3177\"\u003e24-hour timer\u003c\/strong\u003e, \u003cstrong data-start=\"3179\" data-end=\"3203\"\u003ebase heating\u003c\/strong\u003e, \u003cstrong data-start=\"3205\" data-end=\"3233\"\u003ecompressor heating\u003c\/strong\u003e, \u003cstrong data-start=\"3235\" data-end=\"3264\"\u003efireproof electrical box\u003c\/strong\u003e, and \u003cstrong data-start=\"3268\" data-end=\"3310\"\u003eauto-adaptive voltage technology\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3351\" data-end=\"3763\"\u003eAt AirGreen, we often see customers who just want “a small heat pump,” but the right choice always requires more precision. A wall unit must be chosen according to the room, but also according to how the air actually circulates. A closed bedroom, a south-facing office, and an open-concept condo do not behave the same way, even if the area seems similar.\u003c\/p\u003e\n\u003ch2 data-start=\"3765\" data-end=\"3830\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3768\" data-end=\"3830\"\u003e2. Important technical features of the ZE-09CB25\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3832\" data-end=\"3945\"\u003eFor the model \u003cstrong data-start=\"3847\" data-end=\"3872\"\u003eZephyr CB25 ZE-09CB25\u003c\/strong\u003e, the main data indicated in the brochure are as follows:\u003c\/p\u003e\n\u003cp data-start=\"3947\" data-end=\"5107\"\u003e\u003cstrong data-start=\"3947\" data-end=\"3966\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"3966\" data-end=\"3969\"\u003e\u003cstrong data-start=\"3969\" data-end=\"3985\"\u003eSeries: CB25\u003c\/strong\u003e\u003cbr data-start=\"3985\" data-end=\"3988\"\u003e\u003cstrong data-start=\"3988\" data-end=\"4010\"\u003eModel: ZE-09CB25\u003c\/strong\u003e\u003cbr data-start=\"4010\" data-end=\"4013\"\u003e\u003cstrong data-start=\"4013\" data-end=\"4042\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"4042\" data-end=\"4045\"\u003e\u003cstrong data-start=\"4045\" data-end=\"4068\"\u003eRefrigerant: R454B\u003c\/strong\u003e\u003cbr data-start=\"4068\" data-end=\"4071\"\u003e\u003cstrong data-start=\"4071\" data-end=\"4124\"\u003eCooling capacity at 35 °C: 9,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4124\" data-end=\"4127\"\u003e\u003cstrong data-start=\"4127\" data-end=\"4175\"\u003eHeating capacity at 8.3 °C: 9,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4175\" data-end=\"4178\"\u003e\u003cstrong data-start=\"4178\" data-end=\"4194\"\u003eSEER2: 25.0\u003c\/strong\u003e\u003cbr data-start=\"4194\" data-end=\"4197\"\u003e\u003cstrong data-start=\"4197\" data-end=\"4216\"\u003eHSPF2 IV: 11.0\u003c\/strong\u003e\u003cbr data-start=\"4216\" data-end=\"4219\"\u003e\u003cstrong data-start=\"4219\" data-end=\"4235\"\u003eEER2: 13.65\u003c\/strong\u003e\u003cbr data-start=\"4235\" data-end=\"4238\"\u003e\u003cstrong data-start=\"4238\" data-end=\"4271\"\u003eHeating COP at 8.3 °C: 3.88\u003c\/strong\u003e\u003cbr data-start=\"4271\" data-end=\"4274\"\u003e\u003cstrong data-start=\"4274\" data-end=\"4296\"\u003eCOP at -15 °C: 2.1\u003c\/strong\u003e\u003cbr data-start=\"4296\" data-end=\"4299\"\u003e\u003cstrong data-start=\"4299\" data-end=\"4325\"\u003eEnergy Star V6.1: Yes\u003c\/strong\u003e\u003cbr data-start=\"4325\" data-end=\"4328\"\u003e\u003cstrong data-start=\"4328\" data-end=\"4359\"\u003eAirflow: 253 to 383 CFM\u003c\/strong\u003e\u003cbr data-start=\"4359\" data-end=\"4362\"\u003e\u003cstrong data-start=\"4362\" data-end=\"4427\"\u003eIndoor sound pressure: 42 \/ 39 \/ 32 \/ 30 \/ 28 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"4427\" data-end=\"4430\"\u003e\u003cstrong data-start=\"4430\" data-end=\"4475\"\u003eOutdoor sound pressure: 53 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"4475\" data-end=\"4478\"\u003e\u003cstrong data-start=\"4478\" data-end=\"4519\"\u003eVoltage: 208V \/ 230V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"4519\" data-end=\"4522\"\u003e\u003cstrong data-start=\"4522\" data-end=\"4536\"\u003eMOP: 15 A\u003c\/strong\u003e\u003cbr data-start=\"4536\" data-end=\"4539\"\u003e\u003cstrong data-start=\"4539\" data-end=\"4554\"\u003eMCA: 9.5 A\u003c\/strong\u003e\u003cbr data-start=\"4554\" data-end=\"4557\"\u003e\u003cstrong data-start=\"4557\" data-end=\"4624\"\u003eRequired communication wire: 4\/14 copper multi-strand 600 V\u003c\/strong\u003e\u003cbr data-start=\"4624\" data-end=\"4627\"\u003e\u003cstrong data-start=\"4627\" data-end=\"4658\"\u003eLiquid piping: 1\/4 in\u003c\/strong\u003e\u003cbr data-start=\"4658\" data-end=\"4661\"\u003e\u003cstrong data-start=\"4661\" data-end=\"4688\"\u003eGas piping: 3\/8 in\u003c\/strong\u003e\u003cbr data-start=\"4688\" data-end=\"4691\"\u003e\u003cstrong data-start=\"4691\" data-end=\"4741\"\u003eMinimum-maximum piping length: 10 to 98 feet\u003c\/strong\u003e\u003cbr data-start=\"4741\" data-end=\"4744\"\u003e\u003cstrong data-start=\"4744\" data-end=\"4781\"\u003eMaximum elevation difference: 50 feet\u003c\/strong\u003e\u003cbr data-start=\"4781\" data-end=\"4784\"\u003e\u003cstrong data-start=\"4784\" data-end=\"4820\"\u003ePrecharge length: 25 feet\u003c\/strong\u003e\u003cbr data-start=\"4820\" data-end=\"4823\"\u003e\u003cstrong data-start=\"4823\" data-end=\"4886\"\u003eIndoor unit dimensions: 33 7\/16 × 11 9\/16 × 8 1\/16 in\u003c\/strong\u003e\u003cbr data-start=\"4886\" data-end=\"4889\"\u003e\u003cstrong data-start=\"4889\" data-end=\"4942\"\u003eOutdoor unit dimensions: 31 7\/8 × 23 × 11 in\u003c\/strong\u003e\u003cbr data-start=\"4942\" data-end=\"4945\"\u003e\u003cstrong data-start=\"4945\" data-end=\"4988\"\u003eAir conditioning range: -15 °C to 48 °C\u003c\/strong\u003e\u003cbr data-start=\"4988\" data-end=\"4991\"\u003e\u003cstrong data-start=\"4991\" data-end=\"5030\"\u003eHeating range: -30 °C to 24 °C\u003c\/strong\u003e\u003cbr data-start=\"5030\" data-end=\"5033\"\u003e\u003cstrong data-start=\"5033\" data-end=\"5069\"\u003eBasic warranty: 10 years parts\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5109\" data-end=\"5546\"\u003eThis data is important because it directly influences the feasibility of the project. For example, the model \u003cstrong data-start=\"5227\" data-end=\"5266\"\u003eZE-09CB25 operates on 208V \/ 230V\u003c\/strong\u003e, unlike the 115V variants of the same family. This means that before confirming an installation, the electrical panel, available circuit breaker, wiring, route between the panel and the outdoor unit, as well as installation compliance must be checked.\u003c\/p\u003e\n\u003ch2 data-start=\"5548\" data-end=\"5620\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5551\" data-end=\"5620\"\u003e3. Why R454B is relevant for a new installation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"5622\" data-end=\"5977\"\u003eThe model \u003cstrong data-start=\"5632\" data-end=\"5674\"\u003eZE-09CB25 uses the refrigerant R454B\u003c\/strong\u003e, a new generation gas increasingly present in modern HVAC equipment. For the customer, the type of refrigerant may sometimes seem secondary, but it plays an important role in the device's design, installation practices, and the transition to newer equipment.\u003c\/p\u003e\n\u003cp data-start=\"5979\" data-end=\"6381\"\u003eA heat pump at \u003cstrong data-start=\"5998\" data-end=\"6007\"\u003eR454B\u003c\/strong\u003e requires rigorous installation. Connections must be clean, flares well made, pressure testing properly done, vacuum pulling thorough, and pipe length must meet the manufacturer's requirements. A modern device can offer excellent performance, but only if installed according to best practices.\u003c\/p\u003e\n\u003cp data-start=\"6383\" data-end=\"6703\"\u003eAt AirGreen, we emphasize this point: \u003cstrong data-start=\"6428\" data-end=\"6540\"\u003ethe real performance of a heat pump depends as much on installation quality as on the technical sheet\u003c\/strong\u003e. A good unit poorly installed can lose efficiency, become noisy, cause drainage problems, or provide less comfort than expected.\u003c\/p\u003e\n\u003ch2 data-start=\"6705\" data-end=\"6758\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6708\" data-end=\"6758\"\u003e4. Winter comfort: heating down to -30 °C\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"6760\" data-end=\"7117\"\u003eOne of the major advantages of the Zephyr CB25 ZE-09CB25 is its ability to operate in heating mode down to \u003cstrong data-start=\"6866\" data-end=\"6876\"\u003e-30 °C\u003c\/strong\u003e according to the brochure. For Quebec, this is a crucial point. Winters in Montreal, Laval, Longueuil, on the North Shore and South Shore can quickly challenge a wall-mounted heat pump, especially during prolonged cold periods.\u003c\/p\u003e\n\u003cp data-start=\"7119\" data-end=\"7204\"\u003eThe technical sheet also indicates heating capacities at low temperatures:\u003c\/p\u003e\n\u003cp data-start=\"7206\" data-end=\"7384\"\u003e\u003cstrong data-start=\"7206\" data-end=\"7243\"\u003eHeating at -8.3 °C: 9,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"7243\" data-end=\"7246\"\u003e\u003cstrong data-start=\"7246\" data-end=\"7290\"\u003eMaximum heating at -15 °C: 9,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"7290\" data-end=\"7293\"\u003e\u003cstrong data-start=\"7293\" data-end=\"7337\"\u003eMaximum heating at -20 °C: 6,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"7337\" data-end=\"7340\"\u003e\u003cstrong data-start=\"7340\" data-end=\"7384\"\u003eMaximum heating at -25 °C: 5,000 BTU\/h\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7386\" data-end=\"7702\"\u003eThese figures are very useful because they help to better understand the actual behavior of the device. A heat pump can operate at very low temperatures, but its available capacity may decrease when the cold becomes extreme. That is why a proper building assessment remains necessary.\u003c\/p\u003e\n\u003cp data-start=\"7704\" data-end=\"8001\"\u003eIn a well-insulated bedroom or office, the \u003cstrong data-start=\"7749\" data-end=\"7762\"\u003eZE-09CB25\u003c\/strong\u003e can provide excellent comfort for much of the winter. In a more exposed room, with large windows or older insulation, supplemental heating may still be necessary on the coldest days.\u003c\/p\u003e\n\u003ch2 data-start=\"8003\" data-end=\"8077\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"8006\" data-end=\"8077\"\u003e5. Energy efficiency: a very interesting model at 9,000 BTU\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"8079\" data-end=\"8368\"\u003eWith a \u003cstrong data-start=\"8087\" data-end=\"8104\"\u003eSEER2 of 25.0\u003c\/strong\u003e and an \u003cstrong data-start=\"8111\" data-end=\"8128\"\u003eHSPF2 of 11.0\u003c\/strong\u003e, the Zephyr CB25 ZE-09CB25 positions itself as a very efficient model in its category. The \u003cstrong data-start=\"8221\" data-end=\"8230\"\u003eSEER2\u003c\/strong\u003e reflects seasonal cooling efficiency, while the \u003cstrong data-start=\"8296\" data-end=\"8305\"\u003eHSPF2\u003c\/strong\u003e indicates seasonal heating performance.\u003c\/p\u003e\n\u003cp data-start=\"8370\" data-end=\"8683\"\u003eThe model also features an \u003cstrong data-start=\"8397\" data-end=\"8414\"\u003eEER2 of 13.65\u003c\/strong\u003e and a \u003cstrong data-start=\"8421\" data-end=\"8445\"\u003eCOP of 3.88 at 8.3 °C\u003c\/strong\u003e, confirming its focus on high energy performance. For an owner, this means the device can help reduce operating costs when properly sized, installed, and used.\u003c\/p\u003e\n\u003cp data-start=\"8685\" data-end=\"9051\"\u003eHowever, you should avoid choosing a heat pump based solely on an efficiency number. A device that performs well on paper still needs to be installed in the right place, with the right capacity, proper duct routing, and good indoor ventilation setup. This is what turns theoretical performance into real comfort.\u003c\/p\u003e\n\u003ch2 data-start=\"9053\" data-end=\"9130\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"9056\" data-end=\"9130\"\u003e6. 4D mode, automatic oscillation, and better air distribution\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"9132\" data-end=\"9434\"\u003eThe brochure highlights the \u003cstrong data-start=\"9160\" data-end=\"9171\"\u003e4D mode\u003c\/strong\u003e and \u003cstrong data-start=\"9177\" data-end=\"9204\"\u003eautomatic oscillation\u003c\/strong\u003e, designed to better distribute air throughout the room. This feature is especially useful in spaces where you want to avoid cold spots, poorly conditioned corners, or the feeling of air always directed to the same place.\u003c\/p\u003e\n\u003cp data-start=\"9436\" data-end=\"9723\"\u003eVariable frequency technology also allows the heat pump to adjust its power in real time. Instead of simply operating on\/off like an older system, the device modulates its operation to reduce temperature fluctuations and improve comfort.\u003c\/p\u003e\n\u003cp data-start=\"9725\" data-end=\"9784\"\u003eThe brochure also mentions several practical features:\u003c\/p\u003e\n\u003cp data-start=\"9786\" data-end=\"10154\"\u003e\u003cstrong data-start=\"9786\" data-end=\"9805\"\u003eLED dimmer\u003c\/strong\u003e\u003cbr data-start=\"9805\" data-end=\"9808\"\u003e\u003cstrong data-start=\"9808\" data-end=\"9848\"\u003e5 indoor fan speeds\u003c\/strong\u003e\u003cbr data-start=\"9848\" data-end=\"9851\"\u003e\u003cstrong data-start=\"9851\" data-end=\"9880\"\u003eLED wireless remote control\u003c\/strong\u003e\u003cbr data-start=\"9880\" data-end=\"9883\"\u003e\u003cstrong data-start=\"9883\" data-end=\"9921\"\u003eAutomatic heating 8 °C \/ 46 °F\u003c\/strong\u003e\u003cbr data-start=\"9921\" data-end=\"9924\"\u003e\u003cstrong data-start=\"9924\" data-end=\"9952\"\u003eReversible drain hose\u003c\/strong\u003e\u003cbr data-start=\"9952\" data-end=\"9955\"\u003e\u003cstrong data-start=\"9955\" data-end=\"9973\"\u003eTurbo function\u003c\/strong\u003e\u003cbr data-start=\"9973\" data-end=\"9976\"\u003e\u003cstrong data-start=\"9976\" data-end=\"10001\"\u003eAutomatic defrost\u003c\/strong\u003e\u003cbr data-start=\"10001\" data-end=\"10004\"\u003e\u003cstrong data-start=\"10004\" data-end=\"10029\"\u003eAutomatic cleaning\u003c\/strong\u003e\u003cbr data-start=\"10029\" data-end=\"10032\"\u003e\u003cstrong data-start=\"10032\" data-end=\"10068\"\u003eDiffuser position memory\u003c\/strong\u003e\u003cbr data-start=\"10068\" data-end=\"10071\"\u003e\u003cstrong data-start=\"10071\" data-end=\"10116\"\u003eHeated chassis for the outdoor base\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"10156\" data-end=\"10438\"\u003eThese options make daily use more pleasant. The \u003cstrong data-start=\"10220\" data-end=\"10236\"\u003esilent mode\u003c\/strong\u003e is useful at night, the \u003cstrong data-start=\"10259\" data-end=\"10273\"\u003eiFeel mode\u003c\/strong\u003e helps adjust comfort according to the temperature sensed near the remote control, and the \u003cstrong data-start=\"10362\" data-end=\"10375\"\u003enight mode\u003c\/strong\u003e allows gentler use during rest hours.\u003c\/p\u003e\n\u003ch2 data-start=\"10440\" data-end=\"10504\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10443\" data-end=\"10504\"\u003e7. HVAC installation: the details that make the difference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"10506\" data-end=\"10745\"\u003eInstalling a wall-mounted heat pump is not just about mounting an indoor unit and connecting an outdoor unit. For the \u003cstrong data-start=\"10646\" data-end=\"10671\"\u003eZephyr CB25 ZE-09CB25\u003c\/strong\u003e, several elements must be checked before starting work.\u003c\/p\u003e\n\u003cp data-start=\"10747\" data-end=\"11039\"\u003eThe indoor unit measures \u003cstrong data-start=\"10773\" data-end=\"10806\"\u003e33 7\/16 × 11 9\/16 × 8 1\/16 in\u003c\/strong\u003e. This makes it a compact size, convenient for many residential spaces. However, necessary clearances, mounting height, airflow direction, and refrigerant line routing must still be planned.\u003c\/p\u003e\n\u003cp data-start=\"11041\" data-end=\"11477\"\u003eThe required piping is \u003cstrong data-start=\"11070\" data-end=\"11096\"\u003e1\/4 in for the liquid\u003c\/strong\u003e and \u003cstrong data-start=\"11100\" data-end=\"11122\"\u003e3\/8 in for the gas\u003c\/strong\u003e. The total allowed length is \u003cstrong data-start=\"11160\" data-end=\"11177\"\u003e10 to 98 feet\u003c\/strong\u003e, with a precharge indicated up to \u003cstrong data-start=\"11215\" data-end=\"11227\"\u003e25 feet\u003c\/strong\u003e. When replacing an old unit, one should never assume the existing lines are compatible. At AirGreen, we always check the diameter, condition, length, old refrigerant used, and feasibility of reuse.\u003c\/p\u003e\n\u003cp data-start=\"11479\" data-end=\"11857\"\u003eThe outdoor unit measures \u003cstrong data-start=\"11505\" data-end=\"11528\"\u003e31 7\/8 × 23 × 11 in\u003c\/strong\u003e. Its location must be chosen carefully: clearances, snow, ice, drainage, maintenance access, noise, neighbors, and base stability. On the South Shore, North Shore, and in many areas of Montreal and Laval, space constraints can quickly influence the choice of wall or outdoor location.\u003c\/p\u003e\n\u003ch2 data-start=\"11859\" data-end=\"11903\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11862\" data-end=\"11903\"\u003e8. Noise level and daily comfort\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"11905\" data-end=\"12084\"\u003eThe noise level is often underestimated when purchasing a wall-mounted heat pump. However, in a bedroom, office, or condo, noise can become a deciding factor.\u003c\/p\u003e\n\u003cp data-start=\"12086\" data-end=\"12336\"\u003eThe \u003cstrong data-start=\"12089\" data-end=\"12102\"\u003eZE-09CB25\u003c\/strong\u003e displays an indoor sound pressure level of \u003cstrong data-start=\"12149\" data-end=\"12181\"\u003e42 \/ 39 \/ 32 \/ 30 \/ 28 dB(A)\u003c\/strong\u003e depending on the speed used. This allows operation to be adapted according to needs: more powerful in fast mode, quieter in night or silent mode.\u003c\/p\u003e\n\u003cp data-start=\"12338\" data-end=\"12612\"\u003eThe outdoor unit has a sound pressure level of \u003cstrong data-start=\"12392\" data-end=\"12404\"\u003e53 dB(A)\u003c\/strong\u003e. This level remains reasonable, but location is still important. A unit placed near a bedroom, terrace, narrow yard, or neighbor may be perceived differently depending on the environment.\u003c\/p\u003e\n\u003cp data-start=\"12614\" data-end=\"12781\"\u003eAt AirGreen, we always take the time to recommend a logical location, not only for performance but also for long-term sound comfort.\u003c\/p\u003e\n\u003ch2 data-start=\"12783\" data-end=\"12816\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"12786\" data-end=\"12816\"\u003e9. Maintenance and durability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"12818\" data-end=\"13063\"\u003eA high-performance wall-mounted heat pump must be maintained regularly to retain its efficiency. Even with features like \u003cstrong data-start=\"12952\" data-end=\"12977\"\u003eautomatic cleaning\u003c\/strong\u003e, \u003cstrong data-start=\"12982\" data-end=\"13007\"\u003eautomatic defrosting\u003c\/strong\u003e, and smart modes, maintenance remains essential.\u003c\/p\u003e\n\u003cp data-start=\"13065\" data-end=\"13094\"\u003eWe specifically recommend:\u003c\/p\u003e\n\u003cp data-start=\"13096\" data-end=\"13447\"\u003e\u003cstrong data-start=\"13096\" data-end=\"13134\"\u003eclean the filters regularly\u003c\/strong\u003e,\u003cbr data-start=\"13135\" data-end=\"13138\"\u003e\u003cstrong data-start=\"13138\" data-end=\"13192\"\u003eensure the condensate drain remains clear\u003c\/strong\u003e,\u003cbr data-start=\"13193\" data-end=\"13196\"\u003e\u003cstrong data-start=\"13196\" data-end=\"13260\"\u003ekeep the outdoor unit free of snow, leaves, and debris\u003c\/strong\u003e,\u003cbr data-start=\"13261\" data-end=\"13264\"\u003e\u003cstrong data-start=\"13264\" data-end=\"13301\"\u003emonitor for unusual noises\u003c\/strong\u003e,\u003cbr data-start=\"13302\" data-end=\"13305\"\u003e\u003cstrong data-start=\"13305\" data-end=\"13361\"\u003ehave the device inspected if performance decreases\u003c\/strong\u003e,\u003cbr data-start=\"13362\" data-end=\"13365\"\u003e\u003cstrong data-start=\"13365\" data-end=\"13446\"\u003eschedule professional cleaning when the indoor unit is dirty\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"13449\" data-end=\"13709\"\u003eThe \u003cstrong data-start=\"13459\" data-end=\"13472\"\u003eZE-09CB25\u003c\/strong\u003e model benefits from a \u003cstrong data-start=\"13489\" data-end=\"13534\"\u003ebasic 10-year parts warranty\u003c\/strong\u003e. The brochure also specifies that a labor warranty is available and that you should refer to the distributor for details.\u003c\/p\u003e\n\u003cp data-start=\"13711\" data-end=\"13931\"\u003eAt AirGreen, we always clearly explain the difference between parts warranty, compressor warranty, labor, travel, diagnostics, and maintenance. This helps avoid misunderstandings after installation.\u003c\/p\u003e\n\u003ch2 data-start=\"13933\" data-end=\"14009\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"13936\" data-end=\"14009\"\u003e10. Why choose AirGreen to install the Zephyr CB25 ZE-09CB25\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"14011\" data-end=\"14307\"\u003eAirGreen installs, maintains, and repairs HVAC systems in Greater Montreal, including \u003cstrong data-start=\"14102\" data-end=\"14161\"\u003eMontreal, Laval, Longueuil, the South Shore, and the North Shore\u003c\/strong\u003e. Our field experience allows us to recommend the right solution based on the building, interior layout, and client goals.\u003c\/p\u003e\n\u003cp data-start=\"14309\" data-end=\"14408\"\u003eChoosing AirGreen for a wall-mounted heat pump like the \u003cstrong data-start=\"14363\" data-end=\"14388\"\u003eZephyr CB25 ZE-09CB25\u003c\/strong\u003e means benefiting from:\u003c\/p\u003e\n\u003cp data-start=\"14410\" data-end=\"14851\"\u003e\u003cstrong data-start=\"14410\" data-end=\"14458\"\u003ea clear evaluation before installation\u003c\/strong\u003e,\u003cbr data-start=\"14459\" data-end=\"14462\"\u003e\u003cstrong data-start=\"14462\" data-end=\"14504\"\u003eproper sizing for the space\u003c\/strong\u003e,\u003cbr data-start=\"14505\" data-end=\"14508\"\u003e\u003cstrong data-start=\"14508\" data-end=\"14550\"\u003ethorough electrical inspection\u003c\/strong\u003e,\u003cbr data-start=\"14551\" data-end=\"14554\"\u003e\u003cstrong data-start=\"14554\" data-end=\"14611\"\u003einstallation following good HVAC practices\u003c\/strong\u003e,\u003cbr data-start=\"14612\" data-end=\"14615\"\u003e\u003cstrong data-start=\"14615\" data-end=\"14658\"\u003ethoughtful unit placement\u003c\/strong\u003e,\u003cbr data-start=\"14659\" data-end=\"14662\"\u003e\u003cstrong data-start=\"14662\" data-end=\"14728\"\u003ean honest explanation of low-temperature performance\u003c\/strong\u003e,\u003cbr data-start=\"14729\" data-end=\"14732\"\u003e\u003cstrong data-start=\"14732\" data-end=\"14770\"\u003ea structured after-sales service\u003c\/strong\u003e,\u003cbr data-start=\"14771\" data-end=\"14774\"\u003e\u003cstrong data-start=\"14774\" data-end=\"14850\"\u003ea team experienced with the realities of Quebec homes, condos, and plexes\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"14853\" data-end=\"15176\"\u003eA 9,000 BTU heat pump may seem simple, but the result depends heavily on the installation. A good indoor location improves air distribution. A good outdoor location protects the unit in winter. Proper piping ensures reliability. Proper electrical setup prevents future issues.\u003c\/p\u003e\n\u003ch2 data-start=\"15178\" data-end=\"15279\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"15181\" data-end=\"15279\"\u003e11. Conclusion: a compact, efficient wall-mounted heat pump well suited to the Quebec climate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"15281\" data-end=\"15773\"\u003eThe \u003cstrong data-start=\"15284\" data-end=\"15334\"\u003eZephyr CB25 R454B ZE-09CB25 Wall-Mounted Heat Pump\u003c\/strong\u003e is an excellent option for customers looking for an efficient, modern \u003cstrong data-start=\"15410\" data-end=\"15423\"\u003e9,000 BTU\u003c\/strong\u003e solution capable of heating down to \u003cstrong data-start=\"15490\" data-end=\"15500\"\u003e-30 °C\u003c\/strong\u003e. Its \u003cstrong data-start=\"15506\" data-end=\"15523\"\u003eSEER2 of 25.0\u003c\/strong\u003e, \u003cstrong data-start=\"15529\" data-end=\"15546\"\u003eHSPF2 of 11.0\u003c\/strong\u003e, operation with \u003cstrong data-start=\"15570\" data-end=\"15579\"\u003eR454B\u003c\/strong\u003e, \u003cstrong data-start=\"15585\" data-end=\"15596\"\u003e4D mode\u003c\/strong\u003e, \u003cstrong data-start=\"15602\" data-end=\"15618\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"15624\" data-end=\"15649\"\u003eautomatic defrost\u003c\/strong\u003e, and \u003cstrong data-start=\"15656\" data-end=\"15701\"\u003e10-year basic parts warranty\u003c\/strong\u003e make it a very attractive model for many residential projects.\u003c\/p\u003e\n\u003cp data-start=\"15775\" data-end=\"16033\"\u003eIt is especially suitable for spaces where precise comfort is desired without oversizing the equipment. For a bedroom, office, condo, or closed room, the \u003cstrong data-start=\"15946\" data-end=\"15959\"\u003eZE-09CB25\u003c\/strong\u003e can offer a great balance of comfort, efficiency, and reliability.\u003c\/p\u003e\n\u003cp data-start=\"16035\" data-end=\"16402\"\u003eTo get a clear quote, compare this model with other Zephyr wall-mounted heat pumps, check electrical feasibility, or plan an installation in Montreal, Laval, Longueuil, on the South Shore or North Shore, contact AirGreen. Our team will help you choose the right HVAC solution based on your building, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665926045988,"sku":"ZE-09CB25I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRCB25R454BGRANDMONTREAL_904a3a2a-0fcb-47fa-8a23-4293e2a01379.png?v=1783695918"},{"product_id":"thermopompe-murale-zephyr-cb25-r454b-12000-btu-montreal-laval-rive-sud","title":"ZEPHYR CB25 R454B Wall Heat Pump | 12000 BTU | Montreal, Laval, South Shore","description":"\u003ch1 data-start=\"0\" data-end=\"65\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2\" data-end=\"65\"\u003eZephyr CB25 R454B ZE-12CB25 Wall-Mounted Heat Pump – 12,000 BTU\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch1 data-start=\"67\" data-end=\"160\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"69\" data-end=\"160\"\u003eA modern, efficient 12,000 BTU wall-mounted heat pump designed for comfort in Quebec\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"162\" data-end=\"697\"\u003eThe \u003cstrong data-start=\"165\" data-end=\"226\"\u003eZephyr CB25 R454B ZE-12CB25 12,000 BTU Wall-Mounted Heat Pump\u003c\/strong\u003e is aimed at homeowners looking for a reliable HVAC solution to cool and heat a main room, condo, bedroom, home office, family room, or moderately sized living area. At AirGreen, we recommend this type of device when a client wants a compact, efficient system well suited to the realities of Quebec’s climate, whether in \u003cstrong data-start=\"612\" data-end=\"624\"\u003eMontreal\u003c\/strong\u003e, \u003cstrong data-start=\"626\" data-end=\"635\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"637\" data-end=\"650\"\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong data-start=\"659\" data-end=\"671\"\u003eSouth Shore\u003c\/strong\u003e, or on the \u003cstrong data-start=\"683\" data-end=\"696\"\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"699\" data-end=\"1072\"\u003eThis model stands out for its \u003cstrong data-start=\"729\" data-end=\"750\"\u003eR454B refrigerant\u003c\/strong\u003e, its capacity of \u003cstrong data-start=\"767\" data-end=\"781\"\u003e12,000 BTU\u003c\/strong\u003e, its heating operation down to \u003cstrong data-start=\"823\" data-end=\"833\"\u003e-30 °C\u003c\/strong\u003e, its energy efficiency with a \u003cstrong data-start=\"870\" data-end=\"887\"\u003eSEER2 of 23.0\u003c\/strong\u003e, as well as several comfort features such as \u003cstrong data-start=\"939\" data-end=\"955\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"960\" data-end=\"973\"\u003enight mode\u003c\/strong\u003e, \u003cstrong data-start=\"978\" data-end=\"992\"\u003eiFeel mode\u003c\/strong\u003e, \u003cstrong data-start=\"997\" data-end=\"1008\"\u003e4D mode\u003c\/strong\u003e, \u003cstrong data-start=\"1012\" data-end=\"1039\"\u003eautomatic oscillation\u003c\/strong\u003e, and \u003cstrong data-start=\"1046\" data-end=\"1071\"\u003eautomatic cleaning\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1074\" data-end=\"1549\"\u003eThe Zephyr CB25 ZE-12CB25 is not just a standard wall-mounted heat pump. It is a device that must be properly selected, installed, and configured to deliver its full performance. Before recommending this model, we analyze the area, insulation, ceiling height, air circulation, sun exposure, electrical panel, possible location of the indoor unit, piping route, and location of the outdoor unit.\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1553\" data-end=\"1575\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"2084\" data-end=\"2134\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2087\" data-end=\"2134\"\u003e1. Introduction to the Zephyr CB25 ZE-12CB25\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2136\" data-end=\"2577\"\u003eThe \u003cstrong data-start=\"2139\" data-end=\"2164\"\u003eZephyr CB25 ZE-12CB25\u003c\/strong\u003e is part of the \u003cstrong data-start=\"2189\" data-end=\"2203\"\u003eCB25 R454B\u003c\/strong\u003e series, a range of wall-mounted heat pumps designed to offer a good balance of performance, comfort, and energy efficiency. The brochure presents this series as a solution capable of \u003cstrong data-start=\"2391\" data-end=\"2422\"\u003ewithstanding severe cold\u003c\/strong\u003e, with heating down to \u003cstrong data-start=\"2450\" data-end=\"2460\"\u003e-30 °C\u003c\/strong\u003e and an air conditioning mode that can operate down to \u003cstrong data-start=\"2514\" data-end=\"2524\"\u003e-15 °C\u003c\/strong\u003e outside.\u003c\/p\u003e\n\u003cp data-start=\"2579\" data-end=\"2906\"\u003eFor a Quebec owner, this type of performance is particularly relevant. Our winters are long, variable, and sometimes very cold. A wall-mounted heat pump must therefore be able to operate efficiently for much of the year, not just during the mild days of spring or fall.\u003c\/p\u003e\n\u003cp data-start=\"2908\" data-end=\"3265\"\u003eThe model \u003cstrong data-start=\"2918\" data-end=\"2931\"\u003eZE-12CB25\u003c\/strong\u003e is an interesting option for customers who want to improve the comfort of a specific area without installing a central system. It can suit an open area, a master bedroom, a living room, an office, an extension, a dwelling, or a small commercial space, provided the capacity is well adapted to the building.\u003c\/p\u003e\n\u003ch2 data-start=\"3267\" data-end=\"3316\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3270\" data-end=\"3316\"\u003e2. Important technical characteristics\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3318\" data-end=\"3392\"\u003eFor the model \u003cstrong data-start=\"3333\" data-end=\"3346\"\u003eZE-12CB25\u003c\/strong\u003e, the main data are as follows:\u003c\/p\u003e\n\u003cp data-start=\"3394\" data-end=\"4909\"\u003e• \u003cstrong data-start=\"3396\" data-end=\"3415\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"3415\" data-end=\"3418\"\u003e• \u003cstrong data-start=\"3420\" data-end=\"3442\"\u003eSeries: CB25 R454B\u003c\/strong\u003e\u003cbr data-start=\"3442\" data-end=\"3445\"\u003e• \u003cstrong data-start=\"3447\" data-end=\"3476\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"3476\" data-end=\"3479\"\u003e• \u003cstrong data-start=\"3481\" data-end=\"3503\"\u003eModel: ZE-12CB25\u003c\/strong\u003e\u003cbr data-start=\"3503\" data-end=\"3506\"\u003e• \u003cstrong data-start=\"3508\" data-end=\"3554\"\u003eCooling capacity: 12,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3554\" data-end=\"3557\"\u003e• \u003cstrong data-start=\"3559\" data-end=\"3608\"\u003eHeating capacity at 8.3 °C: 12,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3608\" data-end=\"3611\"\u003e• \u003cstrong data-start=\"3613\" data-end=\"3629\"\u003eSEER2: 23.0\u003c\/strong\u003e\u003cbr data-start=\"3629\" data-end=\"3632\"\u003e• \u003cstrong data-start=\"3634\" data-end=\"3649\"\u003eHSPF2: 9.5\u003c\/strong\u003e\u003cbr data-start=\"3649\" data-end=\"3652\"\u003e• \u003cstrong data-start=\"3654\" data-end=\"3676\"\u003eEER2: 12.25 Btu\/W\u003c\/strong\u003e\u003cbr data-start=\"3676\" data-end=\"3679\"\u003e• \u003cstrong data-start=\"3681\" data-end=\"3718\"\u003eHeating COP at 8.3 °C: 3.80 W\/W\u003c\/strong\u003e\u003cbr data-start=\"3718\" data-end=\"3721\"\u003e• \u003cstrong data-start=\"3723\" data-end=\"3782\"\u003eNominal heating capacity at -8.3 °C: 10,800 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3782\" data-end=\"3785\"\u003e• \u003cstrong data-start=\"3787\" data-end=\"3845\"\u003eMaximum heating capacity at -15 °C: 10,600 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3845\" data-end=\"3848\"\u003e• \u003cstrong data-start=\"3850\" data-end=\"3907\"\u003eMaximum heating capacity at -20 °C: 7,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3907\" data-end=\"3910\"\u003e• \u003cstrong data-start=\"3912\" data-end=\"3969\"\u003eMaximum heating capacity at -25 °C: 6,100 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3969\" data-end=\"3972\"\u003e• \u003cstrong data-start=\"3974\" data-end=\"4000\"\u003eEnergy Star V6.1: yes\u003c\/strong\u003e\u003cbr data-start=\"4000\" data-end=\"4003\"\u003e• \u003cstrong data-start=\"4005\" data-end=\"4036\"\u003eAirflow: 253 to 394 CFM\u003c\/strong\u003e\u003cbr data-start=\"4036\" data-end=\"4039\"\u003e• \u003cstrong data-start=\"4041\" data-end=\"4064\"\u003eRefrigerant: R454B\u003c\/strong\u003e\u003cbr data-start=\"4064\" data-end=\"4067\"\u003e• \u003cstrong data-start=\"4069\" data-end=\"4131\"\u003eIndoor noise level: 46 \/ 39.5 \/ 32.5 \/ 30 \/ 28 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"4131\" data-end=\"4134\"\u003e• \u003cstrong data-start=\"4136\" data-end=\"4174\"\u003eOutdoor noise level: 53 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"4174\" data-end=\"4177\"\u003e• \u003cstrong data-start=\"4179\" data-end=\"4218\"\u003eVoltage: 208\/230 V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"4218\" data-end=\"4221\"\u003e• \u003cstrong data-start=\"4223\" data-end=\"4269\"\u003eNominal cooling current: 4.4 A\u003c\/strong\u003e\u003cbr data-start=\"4269\" data-end=\"4272\"\u003e• \u003cstrong data-start=\"4274\" data-end=\"4314\"\u003eNominal heating current: 4.2 A\u003c\/strong\u003e\u003cbr data-start=\"4314\" data-end=\"4317\"\u003e• \u003cstrong data-start=\"4319\" data-end=\"4333\"\u003eMOP: 15 A\u003c\/strong\u003e\u003cbr data-start=\"4333\" data-end=\"4336\"\u003e• \u003cstrong data-start=\"4338\" data-end=\"4354\"\u003eMCA: 10.5 A\u003c\/strong\u003e\u003cbr data-start=\"4354\" data-end=\"4357\"\u003e• \u003cstrong data-start=\"4359\" data-end=\"4426\"\u003eRequired communication wire: 4\/14 copper multi-strand 600 V\u003c\/strong\u003e\u003cbr data-start=\"4426\" data-end=\"4429\"\u003e• \u003cstrong data-start=\"4431\" data-end=\"4462\"\u003eLiquid piping: 1\/4 in\u003c\/strong\u003e\u003cbr data-start=\"4462\" data-end=\"4465\"\u003e• \u003cstrong data-start=\"4467\" data-end=\"4494\"\u003eGas piping: 3\/8 in\u003c\/strong\u003e\u003cbr data-start=\"4494\" data-end=\"4497\"\u003e• \u003cstrong data-start=\"4499\" data-end=\"4538\"\u003ePiping length: 10 to 98 ft\u003c\/strong\u003e\u003cbr data-start=\"4538\" data-end=\"4541\"\u003e• \u003cstrong data-start=\"4543\" data-end=\"4577\"\u003eMaximum elevation difference: 50 ft\u003c\/strong\u003e\u003cbr data-start=\"4577\" data-end=\"4580\"\u003e• \u003cstrong data-start=\"4582\" data-end=\"4639\"\u003eIndoor unit dimensions: 33.44 x 11.56 x 8.06 in\u003c\/strong\u003e\u003cbr data-start=\"4639\" data-end=\"4642\"\u003e• \u003cstrong data-start=\"4644\" data-end=\"4702\"\u003eOutdoor unit dimensions: 31.88 x 23.00 x 11.00 in\u003c\/strong\u003e\u003cbr data-start=\"4702\" data-end=\"4705\"\u003e• \u003cstrong data-start=\"4707\" data-end=\"4752\"\u003eCooling range: -15 °C to 48 °C\u003c\/strong\u003e\u003cbr data-start=\"4752\" data-end=\"4755\"\u003e• \u003cstrong data-start=\"4757\" data-end=\"4796\"\u003eHeating range: -30 °C to 24 °C\u003c\/strong\u003e\u003cbr data-start=\"4796\" data-end=\"4799\"\u003e• \u003cstrong data-start=\"4801\" data-end=\"4837\"\u003eBasic warranty: 10 years parts\u003c\/strong\u003e\u003cbr data-start=\"4837\" data-end=\"4840\"\u003e• \u003cstrong data-start=\"4842\" data-end=\"4909\"\u003eLabor warranty: available according to the distributor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4911\" data-end=\"5256\"\u003eThis information is important because it directly affects the feasibility of the project. A 12,000 BTU wall-mounted heat pump may seem simple to install, but it is still necessary to check the \u003cstrong data-start=\"5111\" data-end=\"5139\"\u003eelectrical compatibility\u003c\/strong\u003e, \u003cstrong data-start=\"5144\" data-end=\"5170\"\u003epipe diameter\u003c\/strong\u003e, location, clearances, drainage, and refrigerant line length.\u003c\/p\u003e\n\u003ch2 data-start=\"5258\" data-end=\"5299\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5261\" data-end=\"5299\"\u003e3. Why R454B is important\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"5301\" data-end=\"5600\"\u003eThe \u003cstrong data-start=\"5304\" data-end=\"5317\"\u003eZE-12CB25\u003c\/strong\u003e operates with the refrigerant \u003cstrong data-start=\"5349\" data-end=\"5358\"\u003eR454B\u003c\/strong\u003e, a new generation refrigerant increasingly found in recent HVAC equipment. For the customer, this detail may seem secondary, but it is important for installation, service, and system compliance.\u003c\/p\u003e\n\u003cp data-start=\"5602\" data-end=\"5940\"\u003eAt AirGreen, we pay special attention to heat pumps using new refrigerants. A clean installation is essential: \u003cstrong data-start=\"5753\" data-end=\"5778\"\u003ewell-made flares\u003c\/strong\u003e, \u003cstrong data-start=\"5780\" data-end=\"5801\"\u003eleak test\u003c\/strong\u003e, \u003cstrong data-start=\"5803\" data-end=\"5831\"\u003erigorous vacuum pulling\u003c\/strong\u003e, \u003cstrong data-start=\"5833\" data-end=\"5872\"\u003erespect for piping lengths\u003c\/strong\u003e, \u003cstrong data-start=\"5874\" data-end=\"5907\"\u003ecompliant electrical connection\u003c\/strong\u003e, and \u003cstrong data-start=\"5911\" data-end=\"5939\"\u003ecomplete commissioning\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"5942\" data-end=\"6196\"\u003eA modern unit can offer excellent performance, but only if the installation is done correctly. That is why we always emphasize the quality of HVAC work, especially with new generations of wall-mounted heat pumps.\u003c\/p\u003e\n\u003ch2 data-start=\"6198\" data-end=\"6264\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6201\" data-end=\"6264\"\u003e4. Heating down to -30 °C: what it really means\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"6266\" data-end=\"6473\"\u003eThe brochure states that the Zephyr CB25 series can heat down to \u003cstrong data-start=\"6333\" data-end=\"6343\"\u003e-30 °C\u003c\/strong\u003e. This is an important advantage for homeowners in Greater Montreal, where winter temperatures can drop very low.\u003c\/p\u003e\n\u003cp data-start=\"6475\" data-end=\"6760\"\u003eHowever, it is important to understand that heating capacity generally decreases as the outside temperature drops. For the \u003cstrong data-start=\"6617\" data-end=\"6630\"\u003eZE-12CB25\u003c\/strong\u003e model, the technical sheet indicates a capacity of \u003cstrong data-start=\"6675\" data-end=\"6700\"\u003e10,600 BTU\/h at -15 °C\u003c\/strong\u003e, then \u003cstrong data-start=\"6707\" data-end=\"6731\"\u003e7,000 BTU\/h at -20 °C\u003c\/strong\u003e and \u003cstrong data-start=\"6735\" data-end=\"6759\"\u003e6,100 BTU\/h at -25 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"6762\" data-end=\"6993\"\u003eThis means that this heat pump can continue to produce heat at low temperatures, but supplemental heating may still be necessary in some older buildings, less well insulated or very exposed to wind.\u003c\/p\u003e\n\u003cp data-start=\"6995\" data-end=\"7249\"\u003e\u003cstrong data-start=\"6995\" data-end=\"7096\"\u003eHeating down to -30 °C does not mean the unit always delivers 12,000 BTU at -30 °C.\u003c\/strong\u003e This is an important distinction. At AirGreen, we prefer to clearly explain the actual performance rather than create unrealistic expectations.\u003c\/p\u003e\n\u003ch2 data-start=\"7251\" data-end=\"7301\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"7254\" data-end=\"7301\"\u003e5. Indoor comfort and practical functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"7303\" data-end=\"7389\"\u003eThe Zephyr CB25 ZE-12CB25 offers several features designed for everyday comfort:\u003c\/p\u003e\n\u003cp data-start=\"7391\" data-end=\"7811\"\u003e• \u003cstrong data-start=\"7393\" data-end=\"7406\"\u003eNight mode\u003c\/strong\u003e\u003cbr data-start=\"7406\" data-end=\"7409\"\u003e• \u003cstrong data-start=\"7411\" data-end=\"7427\"\u003eSilent mode\u003c\/strong\u003e\u003cbr data-start=\"7427\" data-end=\"7430\"\u003e• \u003cstrong data-start=\"7432\" data-end=\"7446\"\u003eiFeel mode\u003c\/strong\u003e\u003cbr data-start=\"7446\" data-end=\"7449\"\u003e• \u003cstrong data-start=\"7451\" data-end=\"7471\"\u003eQuick start\u003c\/strong\u003e\u003cbr data-start=\"7471\" data-end=\"7474\"\u003e• \u003cstrong data-start=\"7476\" data-end=\"7494\"\u003e24-hour timer\u003c\/strong\u003e\u003cbr data-start=\"7494\" data-end=\"7497\"\u003e• \u003cstrong data-start=\"7499\" data-end=\"7510\"\u003e4D mode\u003c\/strong\u003e\u003cbr data-start=\"7510\" data-end=\"7513\"\u003e• \u003cstrong data-start=\"7515\" data-end=\"7542\"\u003eAutomatic oscillation\u003c\/strong\u003e\u003cbr data-start=\"7542\" data-end=\"7545\"\u003e• \u003cstrong data-start=\"7547\" data-end=\"7565\"\u003eTurbo function\u003c\/strong\u003e\u003cbr data-start=\"7565\" data-end=\"7568\"\u003e• \u003cstrong data-start=\"7570\" data-end=\"7595\"\u003eAutomatic defrost\u003c\/strong\u003e\u003cbr data-start=\"7595\" data-end=\"7598\"\u003e• \u003cstrong data-start=\"7600\" data-end=\"7625\"\u003eAutomatic cleaning\u003c\/strong\u003e\u003cbr data-start=\"7625\" data-end=\"7628\"\u003e• \u003cstrong data-start=\"7630\" data-end=\"7666\"\u003eDiffuser position memory\u003c\/strong\u003e\u003cbr data-start=\"7666\" data-end=\"7669\"\u003e• \u003cstrong data-start=\"7671\" data-end=\"7700\"\u003eLED wireless remote control\u003c\/strong\u003e\u003cbr data-start=\"7700\" data-end=\"7703\"\u003e• \u003cstrong data-start=\"7705\" data-end=\"7724\"\u003eLED attenuator\u003c\/strong\u003e\u003cbr data-start=\"7724\" data-end=\"7727\"\u003e• \u003cstrong data-start=\"7729\" data-end=\"7761\"\u003eAutomatic 8 °C heating\u003c\/strong\u003e\u003cbr data-start=\"7761\" data-end=\"7764\"\u003e• \u003cstrong data-start=\"7766\" data-end=\"7811\"\u003eHeated chassis for the outdoor base\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7813\" data-end=\"8021\"\u003eThe \u003cstrong data-start=\"7816\" data-end=\"7827\"\u003e4D mode\u003c\/strong\u003e and \u003cstrong data-start=\"7833\" data-end=\"7860\"\u003eautomatic oscillation\u003c\/strong\u003e allow better air distribution in the room. This helps limit cold or overly warm spots, especially in open spaces.\u003c\/p\u003e\n\u003cp data-start=\"8023\" data-end=\"8287\"\u003eThe \u003cstrong data-start=\"8026\" data-end=\"8042\"\u003esilent mode\u003c\/strong\u003e is especially useful in a bedroom, office, or relaxation space. With an indoor noise level that can drop to \u003cstrong data-start=\"8181\" data-end=\"8193\"\u003e28 dB(A)\u003c\/strong\u003e, this model can offer discreet operation when properly installed and used.\u003c\/p\u003e\n\u003cp data-start=\"8289\" data-end=\"8602\"\u003eVariable frequency technology also allows the heat pump to adjust its power according to actual needs. Instead of operating only on an on-off basis, it modulates its capacity to maintain a more stable temperature. This improves comfort and can help reduce energy consumption.\u003c\/p\u003e\n\u003ch2 data-start=\"8604\" data-end=\"8654\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"8607\" data-end=\"8654\"\u003e6. HVAC installation: points to verify\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"8656\" data-end=\"8834\"\u003eA good wall-mounted heat pump installation is not just about fixing a unit to the wall. For the \u003cstrong data-start=\"8761\" data-end=\"8774\"\u003eZE-12CB25\u003c\/strong\u003e, several elements must be verified before work begins.\u003c\/p\u003e\n\u003ch3 data-start=\"8836\" data-end=\"8877\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"8840\" data-end=\"8877\"\u003eIndoor unit location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"8879\" data-end=\"9141\"\u003eThe indoor unit measures \u003cstrong data-start=\"8905\" data-end=\"8932\"\u003e33.44 x 11.56 x 8.06 in\u003c\/strong\u003e. It must be installed in a place that allows good air distribution. A poor location can create drafts, uncomfortable areas, or uneven temperature distribution.\u003c\/p\u003e\n\u003cp data-start=\"9143\" data-end=\"9468\"\u003eIn a condo in Montreal, you often have to consider concrete walls, condominium regulations, and drilling constraints. In a house in Laval, Longueuil, on the South Shore or North Shore, the location can be more flexible, but you always need to think about air circulation and the aesthetics of the layout.\u003c\/p\u003e\n\u003ch3 data-start=\"9470\" data-end=\"9511\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"9474\" data-end=\"9511\"\u003eOutdoor unit location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"9513\" data-end=\"9797\"\u003eThe outdoor unit measures \u003cstrong data-start=\"9539\" data-end=\"9567\"\u003e31.88 x 23.00 x 11.00 in\u003c\/strong\u003e. It must be placed on a stable base, with the necessary clearances to ensure good air circulation. Snow, ice, roof water, and future maintenance access must also be considered.\u003c\/p\u003e\n\u003cp data-start=\"9799\" data-end=\"10018\"\u003eThe indicated outdoor noise level is \u003cstrong data-start=\"9841\" data-end=\"9853\"\u003e53 dB(A)\u003c\/strong\u003e. This is reasonable for a wall-mounted heat pump, but the location must still be chosen carefully, especially in denser areas or near neighbors.\u003c\/p\u003e\n\u003ch3 data-start=\"10020\" data-end=\"10051\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10024\" data-end=\"10051\"\u003e1\/4 - 3\/8 inch piping\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"10053\" data-end=\"10218\"\u003eThe model \u003cstrong data-start=\"10063\" data-end=\"10076\"\u003eZE-12CB25\u003c\/strong\u003e uses \u003cstrong data-start=\"10100\" data-end=\"10118\"\u003e1\/4 inch liquid\u003c\/strong\u003e and \u003cstrong data-start=\"10122\" data-end=\"10136\"\u003e3\/8 inch gas\u003c\/strong\u003e piping. This information is essential when replacing an old heat pump.\u003c\/p\u003e\n\u003cp data-start=\"10220\" data-end=\"10498\"\u003eYou should never assume that old wiring is compatible. Before reusing existing piping, we check the diameter, condition of the lines, old refrigerant, total length, accessibility, and the possibility of replacing the route if necessary.\u003c\/p\u003e\n\u003ch3 data-start=\"10500\" data-end=\"10541\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10504\" data-end=\"10541\"\u003e208\/230 V power supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"10543\" data-end=\"10771\"\u003eThis model operates on \u003cstrong data-start=\"10567\" data-end=\"10580\"\u003e208\/230 V\u003c\/strong\u003e, with a \u003cstrong data-start=\"10590\" data-end=\"10605\"\u003e15 A MOP\u003c\/strong\u003e and a \u003cstrong data-start=\"10612\" data-end=\"10629\"\u003e10.5 A MCA\u003c\/strong\u003e. This means the electrical panel, breaker, wire gauge, and circuit compliance must be checked before installation.\u003c\/p\u003e\n\u003cp data-start=\"10773\" data-end=\"10926\"\u003eThis step is very important, especially in older buildings in Montreal or Longueuil, where electrical panels may already be fully loaded.\u003c\/p\u003e\n\u003ch2 data-start=\"10928\" data-end=\"10992\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10931\" data-end=\"10992\"\u003e7. For which spaces to choose a 12,000 BTU heat pump?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"10994\" data-end=\"11140\"\u003eA wall-mounted heat pump \u003cstrong data-start=\"11017\" data-end=\"11031\"\u003e12,000 BTU\u003c\/strong\u003e can suit several types of spaces, but the choice should not be based solely on area.\u003c\/p\u003e\n\u003cp data-start=\"11142\" data-end=\"11166\"\u003eWe always assess:\u003c\/p\u003e\n\u003cp data-start=\"11168\" data-end=\"11560\"\u003e• \u003cstrong data-start=\"11170\" data-end=\"11204\"\u003ethe actual area to be treated\u003c\/strong\u003e;\u003cbr data-start=\"11205\" data-end=\"11208\"\u003e• \u003cstrong data-start=\"11210\" data-end=\"11237\"\u003eceiling height\u003c\/strong\u003e;\u003cbr data-start=\"11238\" data-end=\"11241\"\u003e• \u003cstrong data-start=\"11243\" data-end=\"11258\"\u003einsulation\u003c\/strong\u003e;\u003cbr data-start=\"11259\" data-end=\"11262\"\u003e• \u003cstrong data-start=\"11264\" data-end=\"11294\"\u003ethe orientation of the windows\u003c\/strong\u003e;\u003cbr data-start=\"11295\" data-end=\"11298\"\u003e• \u003cstrong data-start=\"11300\" data-end=\"11326\"\u003esun exposure\u003c\/strong\u003e;\u003cbr data-start=\"11327\" data-end=\"11330\"\u003e• \u003cstrong data-start=\"11332\" data-end=\"11367\"\u003ethe presence of large windows\u003c\/strong\u003e;\u003cbr data-start=\"11368\" data-end=\"11371\"\u003e• \u003cstrong data-start=\"11373\" data-end=\"11405\"\u003ethe opening between rooms\u003c\/strong\u003e;\u003cbr data-start=\"11406\" data-end=\"11409\"\u003e• \u003cstrong data-start=\"11411\" data-end=\"11436\"\u003ethe number of occupants\u003c\/strong\u003e;\u003cbr data-start=\"11437\" data-end=\"11440\"\u003e• \u003cstrong data-start=\"11442\" data-end=\"11471\"\u003ethe use of the room\u003c\/strong\u003e;\u003cbr data-start=\"11472\" data-end=\"11475\"\u003e• \u003cstrong data-start=\"11477\" data-end=\"11512\"\u003ethe need for heating in winter\u003c\/strong\u003e;\u003cbr data-start=\"11513\" data-end=\"11516\"\u003e• \u003cstrong data-start=\"11518\" data-end=\"11559\"\u003ethe need for dehumidification in summer\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"11562\" data-end=\"11905\"\u003eIn a well-insulated condo in Montreal, the ZE-12CB25 can be an excellent choice for the main space. In a house in Laval, it may suit a living room, family room, or a partially open floor. On the South Shore or North Shore, it can be relevant for an extension, an office, a master bedroom, or a rental unit.\u003c\/p\u003e\n\u003cp data-start=\"11907\" data-end=\"12203\"\u003e\u003cstrong data-start=\"11907\" data-end=\"12012\"\u003eAn overly powerful heat pump can reduce dehumidification time and create uneven comfort.\u003c\/strong\u003e Conversely, a unit that is too small may run almost continuously and struggle during very cold or very hot days. Proper sizing remains essential.\u003c\/p\u003e\n\u003ch2 data-start=\"12205\" data-end=\"12238\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"12208\" data-end=\"12238\"\u003e8. Maintenance and durability\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"12240\" data-end=\"12402\"\u003eA well-installed wall-mounted heat pump must also be maintained regularly. To preserve the performance of the \u003cstrong data-start=\"12356\" data-end=\"12381\"\u003eZephyr CB25 ZE-12CB25\u003c\/strong\u003e, we recommend:\u003c\/p\u003e\n\u003cp data-start=\"12404\" data-end=\"12802\"\u003e• \u003cstrong data-start=\"12406\" data-end=\"12444\"\u003eclean the filters regularly\u003c\/strong\u003e;\u003cbr data-start=\"12445\" data-end=\"12448\"\u003e• keep the outdoor unit free of snow, leaves, and debris;\u003cbr data-start=\"12511\" data-end=\"12514\"\u003e• ensure the condensation drain remains clear;\u003cbr data-start=\"12567\" data-end=\"12570\"\u003e• monitor unusual noises;\u003cbr data-start=\"12606\" data-end=\"12609\"\u003e• have the exchanger cleaned when necessary;\u003cbr data-start=\"12657\" data-end=\"12660\"\u003e• request a professional inspection if performance decreases;\u003cbr data-start=\"12728\" data-end=\"12731\"\u003e• check the general condition of the installation before extreme seasons.\u003c\/p\u003e\n\u003cp data-start=\"12804\" data-end=\"13072\"\u003eThe \u003cstrong data-start=\"12807\" data-end=\"12832\"\u003eautomatic cleaning\u003c\/strong\u003e, \u003cstrong data-start=\"12837\" data-end=\"12862\"\u003eautomatic defrosting\u003c\/strong\u003e, and \u003cstrong data-start=\"12869\" data-end=\"12914\"\u003eheated chassis for the outdoor base\u003c\/strong\u003e are useful features, but they do not replace serious maintenance. A clean heat pump works better, consumes less, and lasts longer.\u003c\/p\u003e\n\u003ch2 data-start=\"13074\" data-end=\"13109\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"13077\" data-end=\"13109\"\u003e9. Why choose AirGreen\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"13111\" data-end=\"13404\"\u003eAirGreen installs, maintains, and repairs HVAC systems in Greater Montreal, including \u003cstrong data-start=\"13205\" data-end=\"13217\"\u003eMontreal\u003c\/strong\u003e, \u003cstrong data-start=\"13219\" data-end=\"13228\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"13230\" data-end=\"13243\"\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong data-start=\"13252\" data-end=\"13264\"\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong data-start=\"13271\" data-end=\"13284\"\u003eNorth Shore\u003c\/strong\u003e. Our team understands the realities of condos, single-family homes, plexes, light commercial buildings, and older buildings.\u003c\/p\u003e\n\u003cp data-start=\"13406\" data-end=\"13500\"\u003eBy choosing AirGreen for the installation of the \u003cstrong data-start=\"13456\" data-end=\"13481\"\u003eZephyr CB25 ZE-12CB25\u003c\/strong\u003e, you benefit from:\u003c\/p\u003e\n\u003cp data-start=\"13502\" data-end=\"13945\"\u003e• \u003cstrong data-start=\"13504\" data-end=\"13549\"\u003ea clear assessment before the work\u003c\/strong\u003e;\u003cbr data-start=\"13550\" data-end=\"13553\"\u003e• \u003cstrong data-start=\"13555\" data-end=\"13601\"\u003ea sizing adapted to your space\u003c\/strong\u003e;\u003cbr data-start=\"13602\" data-end=\"13605\"\u003e• \u003cstrong data-start=\"13607\" data-end=\"13649\"\u003ea thorough electrical inspection\u003c\/strong\u003e;\u003cbr data-start=\"13650\" data-end=\"13653\"\u003e• \u003cstrong data-start=\"13655\" data-end=\"13712\"\u003ean installation compliant with good HVAC practices\u003c\/strong\u003e;\u003cbr data-start=\"13713\" data-end=\"13716\"\u003e• \u003cstrong data-start=\"13718\" data-end=\"13777\"\u003ean honest explanation of heating performance\u003c\/strong\u003e;\u003cbr data-start=\"13778\" data-end=\"13781\"\u003e• \u003cstrong data-start=\"13783\" data-end=\"13834\"\u003esupport to understand the warranty\u003c\/strong\u003e;\u003cbr data-start=\"13835\" data-end=\"13838\"\u003e• \u003cstrong data-start=\"13840\" data-end=\"13878\"\u003ea structured after-sales service\u003c\/strong\u003e;\u003cbr data-start=\"13879\" data-end=\"13882\"\u003e• \u003cstrong data-start=\"13884\" data-end=\"13944\"\u003ean experienced team in wall installations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"13947\" data-end=\"14106\"\u003eOur goal is simple: to install a heat pump that truly meets the client’s needs, not just a device that looks good on paper.\u003c\/p\u003e\n\u003ch2 data-start=\"14108\" data-end=\"14129\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"14111\" data-end=\"14129\"\u003e10. Conclusion\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"14131\" data-end=\"14606\"\u003eThe \u003cstrong data-start=\"14134\" data-end=\"14195\"\u003eZephyr CB25 R454B ZE-12CB25 12,000 BTU Wall Heat Pump\u003c\/strong\u003e is an attractive solution for owners who want a modern, efficient device suited to the Quebec climate. With its \u003cstrong data-start=\"14331\" data-end=\"14348\"\u003eSEER2 of 23.0\u003c\/strong\u003e, \u003cstrong data-start=\"14354\" data-end=\"14375\"\u003eR454B refrigerant\u003c\/strong\u003e, \u003cstrong data-start=\"14381\" data-end=\"14409\"\u003eheating down to -30 °C\u003c\/strong\u003e, \u003cstrong data-start=\"14415\" data-end=\"14444\"\u003equiet operation\u003c\/strong\u003e, \u003cstrong data-start=\"14450\" data-end=\"14470\"\u003eEnergy Star V6.1\u003c\/strong\u003e, and \u003cstrong data-start=\"14477\" data-end=\"14514\"\u003e10-year basic parts warranty\u003c\/strong\u003e, it represents a solid choice for many residential and light commercial projects.\u003c\/p\u003e\n\u003cp data-start=\"14608\" data-end=\"14842\"\u003eHowever, it requires a well-planned installation. The \u003cstrong data-start=\"14667\" data-end=\"14694\"\u003e1\/4 - 3\/8 inch piping\u003c\/strong\u003e, the \u003cstrong data-start=\"14711\" data-end=\"14724\"\u003e208\/230 V power supply\u003c\/strong\u003e, the \u003cstrong data-start=\"14729\" data-end=\"14744\"\u003e15 A MOP\u003c\/strong\u003e, drainage, clearances, and unit locations must be verified before work begins.\u003c\/p\u003e\n\u003cp data-start=\"14844\" data-end=\"15174\"\u003eTo get a clear quote, compare this model with other options or schedule an installation in \u003cstrong data-start=\"14953\" data-end=\"14965\"\u003eMontreal\u003c\/strong\u003e, \u003cstrong data-start=\"14967\" data-end=\"14976\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"14978\" data-end=\"14991\"\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong data-start=\"15000\" data-end=\"15012\"\u003eSouth Shore\u003c\/strong\u003e or the \u003cstrong data-start=\"15019\" data-end=\"15032\"\u003eNorth Shore\u003c\/strong\u003e, contact AirGreen. Our team will help you choose the right HVAC solution based on your building, budget, and comfort expectations.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665926144292,"sku":"ZE-12CB25I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRCB25R454BGRANDMONTREAL_27d5a71a-5210-4b4a-886d-e915c95d1b7e.png?v=1783695913"},{"product_id":"thermopompe-murale-zephyr-cb25-r454b-18000-btu-montreal-laval-rive-sud","title":"ZEPHYR CB25 R454B Wall Heat Pump | 18000 BTU | Montreal, Laval, South Shore","description":"\u003ch1 data-start=\"0\" data-end=\"60\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2\" data-end=\"60\"\u003eZephyr ZE-18CB25 R454B Wall-Mounted Heat Pump – 18,000 BTU\u003c\/strong\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003ch2 data-start=\"62\" data-end=\"193\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"65\" data-end=\"193\"\u003eAn 18,000 BTU wall-mounted heat pump designed to withstand the cold, stabilize comfort, and reduce energy consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"195\" data-end=\"761\"\u003eThe \u003cstrong data-start=\"198\" data-end=\"254\"\u003eZephyr ZE-18CB25 R454B 18,000 BTU wall-mounted heat pump\u003c\/strong\u003e is aimed at owners looking for a reliable HVAC solution to cool and heat a medium to large space, such as an open area, a main living room, a house floor, a spacious condo, an office, or a light commercial space. At AirGreen, we recommend this type of unit when the client wants a machine capable of offering a \u003cstrong data-start=\"612\" data-end=\"702\"\u003egood balance between power, efficiency, acoustic comfort, and winter performance\u003c\/strong\u003e, while remaining suited to the realities of the Quebec climate.\u003c\/p\u003e\n\u003cp data-start=\"763\" data-end=\"1282\"\u003eThis model stands out for its \u003cstrong data-start=\"793\" data-end=\"819\"\u003e18,000 BTU capacity\u003c\/strong\u003e, its operation with \u003cstrong data-start=\"843\" data-end=\"864\"\u003eR454B refrigerant\u003c\/strong\u003e, its heating performance down to \u003cstrong data-start=\"902\" data-end=\"912\"\u003e-30 °C\u003c\/strong\u003e, its efficiency reaching up to \u003cstrong data-start=\"947\" data-end=\"961\"\u003e21.0 SEER2\u003c\/strong\u003e, as well as its \u003cstrong data-start=\"989\" data-end=\"1013\"\u003eInverter technology\u003c\/strong\u003e design. In practice, this means the device does not simply operate on an on\/off basis like a traditional system: it adjusts its power according to actual demand, which helps maintain a more stable temperature and limits uncomfortable fluctuations.\u003c\/p\u003e\n\u003cp data-start=\"1284\" data-end=\"1706\"\u003eThe Zephyr ZE-18CB25 is therefore not just a wall-mounted heat pump for heating and cooling. It is a complete solution that must be chosen according to several criteria: room dimensions, insulation, ceiling height, sun exposure, location of the indoor unit, position of the outdoor unit, electrical supply, piping length, drainage, and client expectations in both winter and summer.\u003c\/p\u003e\n\u003cp data-start=\"1708\" data-end=\"2265\"\u003eAt AirGreen, we install wall-mounted systems in a wide variety of settings in \u003cstrong data-start=\"1792\" data-end=\"1855\"\u003eMontreal, Laval, Longueuil, on the South Shore and the North Shore\u003c\/strong\u003e. Our experience shows us that a model that performs well on paper only delivers its best results when it is \u003cstrong data-start=\"1975\" data-end=\"2028\"\u003eproperly sized, properly installed, and properly configured\u003c\/strong\u003e. A poorly placed heat pump can create cold or hot spots, unnecessary noise, problematic drainage, or less consistent performance. Conversely, a well-thought-out installation truly transforms the comfort of a space.\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2270\" data-end=\"2282\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"2993\" data-end=\"3132\"\u003eFor the \u003cstrong data-start=\"3001\" data-end=\"3021\"\u003eZephyr ZE-18CB25\u003c\/strong\u003e, the main data indicated in the brochure are as follows:\u003c\/p\u003e\n\u003cp data-start=\"3134\" data-end=\"4356\"\u003e• \u003cstrong data-start=\"3136\" data-end=\"3155\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"3155\" data-end=\"3158\"\u003e• \u003cstrong data-start=\"3160\" data-end=\"3176\"\u003eSeries: CB25\u003c\/strong\u003e\u003cbr data-start=\"3176\" data-end=\"3179\"\u003e• \u003cstrong data-start=\"3181\" data-end=\"3203\"\u003eModel: ZE-18CB25\u003c\/strong\u003e\u003cbr data-start=\"3203\" data-end=\"3206\"\u003e• \u003cstrong data-start=\"3208\" data-end=\"3237\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"3237\" data-end=\"3240\"\u003e• \u003cstrong data-start=\"3242\" data-end=\"3296\"\u003eCooling capacity at 35 °C: 18,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3296\" data-end=\"3299\"\u003e• \u003cstrong data-start=\"3301\" data-end=\"3350\"\u003eHeating capacity at 8.3 °C: 18,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3350\" data-end=\"3353\"\u003e• \u003cstrong data-start=\"3355\" data-end=\"3378\"\u003eRefrigerant: R454B\u003c\/strong\u003e\u003cbr data-start=\"3378\" data-end=\"3381\"\u003e• \u003cstrong data-start=\"3383\" data-end=\"3399\"\u003eSEER2: 21.0\u003c\/strong\u003e\u003cbr data-start=\"3399\" data-end=\"3402\"\u003e• \u003cstrong data-start=\"3404\" data-end=\"3422\"\u003eHSPF2 IV: 9.5\u003c\/strong\u003e\u003cbr data-start=\"3422\" data-end=\"3425\"\u003e• \u003cstrong data-start=\"3427\" data-end=\"3449\"\u003eEER2: 12.10 Btu\/W\u003c\/strong\u003e\u003cbr data-start=\"3449\" data-end=\"3452\"\u003e• \u003cstrong data-start=\"3454\" data-end=\"3487\"\u003eHeating COP at 8.3 °C: 3.61\u003c\/strong\u003e\u003cbr data-start=\"3487\" data-end=\"3490\"\u003e• \u003cstrong data-start=\"3492\" data-end=\"3514\"\u003eCOP at -15 °C: 1.9\u003c\/strong\u003e\u003cbr data-start=\"3514\" data-end=\"3517\"\u003e• \u003cstrong data-start=\"3519\" data-end=\"3545\"\u003eENERGY STAR V6.1: yes\u003c\/strong\u003e\u003cbr data-start=\"3545\" data-end=\"3548\"\u003e• \u003cstrong data-start=\"3550\" data-end=\"3591\"\u003eIndoor airflow: 383 to 647 CFM\u003c\/strong\u003e\u003cbr data-start=\"3591\" data-end=\"3594\"\u003e• \u003cstrong data-start=\"3596\" data-end=\"3661\"\u003eIndoor sound pressure: 48 \/ 45 \/ 41 \/ 36 \/ 33 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"3661\" data-end=\"3664\"\u003e• \u003cstrong data-start=\"3666\" data-end=\"3711\"\u003eOutdoor sound pressure: 58 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"3711\" data-end=\"3714\"\u003e• \u003cstrong data-start=\"3716\" data-end=\"3757\"\u003eVoltage: 208V \/ 230V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"3757\" data-end=\"3760\"\u003e• \u003cstrong data-start=\"3762\" data-end=\"3806\"\u003eNominal cooling current: 6.1 A\u003c\/strong\u003e\u003cbr data-start=\"3806\" data-end=\"3809\"\u003e• \u003cstrong data-start=\"3811\" data-end=\"3851\"\u003eNominal heating current: 6.5 A\u003c\/strong\u003e\u003cbr data-start=\"3893\" data-end=\"3896\"\u003e• \u003cstrong data-start=\"3898\" data-end=\"3961\"\u003eRequired communication wire: 4\/14 copper multi-strand 600V\u003c\/strong\u003e\u003cbr data-start=\"3961\" data-end=\"3964\"\u003e• \u003cstrong data-start=\"3966\" data-end=\"3997\"\u003eLiquid piping: 1\/4 in\u003c\/strong\u003e\u003cbr data-start=\"3997\" data-end=\"4000\"\u003e• \u003cstrong data-start=\"4002\" data-end=\"4029\"\u003eGas piping: 1\/2 in\u003c\/strong\u003e\u003cbr data-start=\"4029\" data-end=\"4032\"\u003e• \u003cstrong data-start=\"4034\" data-end=\"4084\"\u003eMinimum-maximum piping length: 10 to 98 feet\u003c\/strong\u003e\u003cbr data-start=\"4084\" data-end=\"4087\"\u003e• \u003cstrong data-start=\"4089\" data-end=\"4126\"\u003eMaximum elevation difference: 50 feet\u003c\/strong\u003e\u003cbr data-start=\"4126\" data-end=\"4129\"\u003e• \u003cstrong data-start=\"4131\" data-end=\"4167\"\u003ePrecharge length: 25 feet\u003c\/strong\u003e\u003cbr data-start=\"4167\" data-end=\"4170\"\u003e• \u003cstrong data-start=\"4172\" data-end=\"4202\"\u003eCompressor: GMCC rotary\u003c\/strong\u003e\u003cbr data-start=\"4202\" data-end=\"4205\"\u003e• \u003cstrong data-start=\"4207\" data-end=\"4238\"\u003eExpansion device: EEV\u003c\/strong\u003e\u003cbr data-start=\"4238\" data-end=\"4241\"\u003e• \u003cstrong data-start=\"4243\" data-end=\"4272\"\u003eIndoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"4272\" data-end=\"4275\"\u003e• \u003cstrong data-start=\"4277\" data-end=\"4306\"\u003eOutdoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"4306\" data-end=\"4309\"\u003e• \u003cstrong data-start=\"4311\" data-end=\"4354\"\u003eZephyr basic warranty: 10 years parts\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4358\" data-end=\"4519\"\u003eThe brochure shows dimensions in \u003cstrong data-start=\"4404\" data-end=\"4417\"\u003eL × H × D\u003c\/strong\u003e format. For easier reading, here are the dimensions in \u003cstrong data-start=\"4483\" data-end=\"4496\"\u003eL × D × H\u003c\/strong\u003e format, with two decimals:\u003c\/p\u003e\n\u003cp data-start=\"4521\" data-end=\"4621\"\u003e• \u003cstrong data-start=\"4523\" data-end=\"4569\"\u003eIndoor unit: 42.06 × 9.06 × 12.63 in\u003c\/strong\u003e\u003cbr data-start=\"4569\" data-end=\"4572\"\u003e• \u003cstrong data-start=\"4574\" data-end=\"4621\"\u003eOutdoor unit: 33.88 × 12.19 × 25.50 in\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4623\" data-end=\"5133\"\u003eThese figures are not just technical information. They directly influence project feasibility, installation cost, breaker choice, refrigerant line routing, outdoor unit placement, and final performance. An \u003cstrong data-start=\"4907\" data-end=\"4936\"\u003e18,000 BTU heat pump at 208V \/ 230V\u003c\/strong\u003e should not be treated like a small 9,000 BTU wall unit. It requires serious verification of electrical supply, distance between units, and available space.\u003c\/p\u003e\n\u003ch2 data-start=\"5135\" data-end=\"5211\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5138\" data-end=\"5211\"\u003eWhy R454B is relevant for new HVAC installations\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"5213\" data-end=\"5493\"\u003eThe Zephyr ZE-18CB25 uses \u003cstrong data-start=\"5244\" data-end=\"5265\"\u003eR454B refrigerant\u003c\/strong\u003e, a new generation gas increasingly present in modern HVAC equipment. For the client, the name of the refrigerant may seem secondary, but it is one of the important elements to consider when making a purchase.\u003c\/p\u003e\n\u003cp data-start=\"5495\" data-end=\"5879\"\u003eThe choice of refrigerant influences the design of the device, work methods, installation requirements, and best practices in the field. A modern R454B heat pump requires a rigorous installation: \u003cstrong data-start=\"5723\" data-end=\"5878\"\u003eclean flares, leak test, serious vacuum pulling, respect for pipe lengths, electrical verification, and full commissioning\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"5881\" data-end=\"6246\"\u003eAt AirGreen, we pay special attention to these steps because a modern device does not forgive a sloppy installation. Even a high-performance machine can lose efficiency if the lines are poorly prepared, if the vacuum is too fast, if the drainage is poorly planned, or if the outdoor location does not respect the necessary clearances.\u003c\/p\u003e\n\u003cp data-start=\"6248\" data-end=\"6498\"\u003eFor clients in \u003cstrong data-start=\"6267\" data-end=\"6330\"\u003eMontreal, Laval, Longueuil, on the South Shore and the North Shore\u003c\/strong\u003e, R454B represents a transition to newer systems, better adapted to new standards and current expectations regarding energy performance.\u003c\/p\u003e\n\u003ch2 data-start=\"6500\" data-end=\"6555\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6503\" data-end=\"6555\"\u003eAn 18,000 BTU capacity: for which spaces?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"6557\" data-end=\"6855\"\u003eAn 18,000 BTU wall-mounted heat pump is often chosen for spaces larger than a simple bedroom or small office. It can suit an open area, a living room, a partially open ground floor, a well-sized home, a spacious condo, or a small commercial space.\u003c\/p\u003e\n\u003cp data-start=\"6857\" data-end=\"7052\"\u003eHowever, the number of BTUs alone is never enough to confirm that a device is well chosen. At AirGreen, we always analyze several elements before recommending a machine:\u003c\/p\u003e\n\u003cp data-start=\"7054\" data-end=\"7483\"\u003e• \u003cstrong data-start=\"7056\" data-end=\"7090\"\u003ethe actual area to be treated\u003c\/strong\u003e;\u003cbr data-start=\"7091\" data-end=\"7094\"\u003e• \u003cstrong data-start=\"7096\" data-end=\"7123\"\u003eceiling height\u003c\/strong\u003e;\u003cbr data-start=\"7124\" data-end=\"7127\"\u003e• \u003cstrong data-start=\"7129\" data-end=\"7158\"\u003einsulation quality\u003c\/strong\u003e;\u003cbr data-start=\"7159\" data-end=\"7162\"\u003e• \u003cstrong data-start=\"7164\" data-end=\"7194\"\u003ewindow orientation\u003c\/strong\u003e;\u003cbr data-start=\"7195\" data-end=\"7198\"\u003e• \u003cstrong data-start=\"7200\" data-end=\"7228\"\u003esolar load in summer\u003c\/strong\u003e;\u003cbr data-start=\"7229\" data-end=\"7232\"\u003e• \u003cstrong data-start=\"7234\" data-end=\"7275\"\u003eair circulation between rooms\u003c\/strong\u003e;\u003cbr data-start=\"7276\" data-end=\"7279\"\u003e• \u003cstrong data-start=\"7281\" data-end=\"7324\"\u003ethe presence of stairs or corridors\u003c\/strong\u003e;\u003cbr data-start=\"7325\" data-end=\"7328\"\u003e• \u003cstrong data-start=\"7330\" data-end=\"7371\"\u003ethe expected comfort level in winter\u003c\/strong\u003e;\u003cbr data-start=\"7372\" data-end=\"7375\"\u003e• \u003cstrong data-start=\"7377\" data-end=\"7439\"\u003ethe distance between the indoor and outdoor units\u003c\/strong\u003e;\u003cbr data-start=\"7440\" data-end=\"7443\"\u003e• \u003cstrong data-start=\"7445\" data-end=\"7482\"\u003eavailable electrical capacity\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"7485\" data-end=\"8002\"\u003eIn a bungalow in Laval, an 18,000 BTU unit can be an excellent solution for a main open area. In a condo in Montreal, it can be relevant if the space is long, very windowed, or difficult to balance. On the South Shore, in a recent house with large windows, the cooling load may justify a capacity higher than the area suggests. On the North Shore, in a house more exposed to wind, heating performance becomes an even more important factor.\u003c\/p\u003e\n\u003cp data-start=\"8004\" data-end=\"8487\"\u003eIt is also important to avoid the trap of oversizing. An overly powerful heat pump can reach the temperature quickly without properly dehumidifying the air in summer. The result: the room feels cool but not always comfortable. Conversely, an undersized heat pump runs almost continuously and may struggle during very cold or very hot days. \u003cstrong data-start=\"8387\" data-end=\"8487\"\u003eThe right choice is a balance between power, efficiency, comfort, and building configuration.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"8489\" data-end=\"8557\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"8492\" data-end=\"8557\"\u003eEnergy performance: understanding the numbers wisely\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"8559\" data-end=\"8743\"\u003eThe Zephyr ZE-18CB25 features a \u003cstrong data-start=\"8590\" data-end=\"8607\"\u003eSEER2 of 21.0\u003c\/strong\u003e, a \u003cstrong data-start=\"8612\" data-end=\"8631\"\u003eHSPF2 IV of 9.5\u003c\/strong\u003e, and a \u003cstrong data-start=\"8638\" data-end=\"8661\"\u003eEER2 of 12.10 Btu\/W\u003c\/strong\u003e. These indicators help evaluate the heat pump’s energy efficiency.\u003c\/p\u003e\n\u003cp data-start=\"8745\" data-end=\"9146\"\u003eThe \u003cstrong data-start=\"8748\" data-end=\"8757\"\u003eSEER2\u003c\/strong\u003e measures seasonal cooling efficiency. The higher it is, the more efficient the unit is during the warm season. The \u003cstrong data-start=\"8885\" data-end=\"8894\"\u003eHSPF2\u003c\/strong\u003e relates more to heating efficiency over a season. The \u003cstrong data-start=\"8956\" data-end=\"8964\"\u003eEER2\u003c\/strong\u003e provides an indication of performance under specific cooling conditions. The \u003cstrong data-start=\"9051\" data-end=\"9058\"\u003eCOP\u003c\/strong\u003e indicates the ratio between thermal energy produced and electricity consumed.\u003c\/p\u003e\n\u003cp data-start=\"9148\" data-end=\"9531\"\u003eFor a homeowner, the goal is not to memorize every figure but to understand that this data can influence operating costs. A high-performance heat pump like the ZE-18CB25 can help reduce electricity consumption compared to direct electric heating, especially during periods when the outside temperature remains within a favorable range.\u003c\/p\u003e\n\u003cp data-start=\"9533\" data-end=\"9912\"\u003eThe brochure also states that this model is \u003cstrong data-start=\"9577\" data-end=\"9597\"\u003eENERGY STAR V6.1\u003c\/strong\u003e, which is an important point for customers looking for a more efficient solution better suited to current standards. Before promising a subsidy, however, eligibility must be verified according to the current program, the applicable AHRI number, and the conditions at the time of application.\u003c\/p\u003e\n\u003ch2 data-start=\"9914\" data-end=\"9977\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"9917\" data-end=\"9977\"\u003eHeating down to -30 °C: what it really means\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"9979\" data-end=\"10160\"\u003eThe Zephyr brochure indicates a heating operating range of \u003cstrong data-start=\"10050\" data-end=\"10068\"\u003e-30 °C to 24 °C\u003c\/strong\u003e. This is an important argument for Quebec, where winters can be long and demanding.\u003c\/p\u003e\n\u003cp data-start=\"10162\" data-end=\"10465\"\u003eHowever, it is important to understand what it means for a heat pump to be capable of operating down to -30 °C. This does not mean the machine produces exactly the same capacity at -25 °C as at +8 °C. Like all heat pumps, its available capacity decreases as the outside temperature drops.\u003c\/p\u003e\n\u003cp data-start=\"10467\" data-end=\"10524\"\u003eFor the ZE-18CB25, the technical sheet notably indicates:\u003c\/p\u003e\n\u003cp data-start=\"10526\" data-end=\"10751\"\u003e• \u003cstrong data-start=\"10528\" data-end=\"10574\"\u003eNominal capacity at -8.3 °C: 18,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"10574\" data-end=\"10577\"\u003e• \u003cstrong data-start=\"10579\" data-end=\"10624\"\u003eMaximum capacity at -15 °C: 18,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"10624\" data-end=\"10627\"\u003e• \u003cstrong data-start=\"10629\" data-end=\"10674\"\u003eMaximum capacity at -20 °C: 12,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"10674\" data-end=\"10677\"\u003e• \u003cstrong data-start=\"10679\" data-end=\"10724\"\u003eMaximum capacity at -25 °C: 11,500 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"10724\" data-end=\"10727\"\u003e• \u003cstrong data-start=\"10729\" data-end=\"10751\"\u003eCOP at -15 °C: 1.9\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"10753\" data-end=\"11083\"\u003eThese figures are very useful for a realistic assessment. In a well-insulated house, this performance can cover a large part of the heating needs of the treated area. In an older house, with many windows or exposed to wind, supplementary heating may still be necessary on the coldest days.\u003c\/p\u003e\n\u003cp data-start=\"11085\" data-end=\"11327\"\u003eAt AirGreen, we explain this point clearly. \u003cstrong data-start=\"11137\" data-end=\"11237\"\u003eA high-performance wall-mounted heat pump can significantly reduce the use of electric baseboards\u003c\/strong\u003e, but it must be smartly integrated into the home's heating strategy.\u003c\/p\u003e\n\u003ch2 data-start=\"11329\" data-end=\"11385\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11332\" data-end=\"11385\"\u003eInstallation: the details that make the difference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"11387\" data-end=\"11547\"\u003eA good wall-mounted heat pump installation is not just about mounting the indoor unit on the wall. For a \u003cstrong data-start=\"11493\" data-end=\"11524\"\u003eZephyr ZE-18CB25 18,000 BTU\u003c\/strong\u003e, every detail matters.\u003c\/p\u003e\n\u003ch3 data-start=\"11549\" data-end=\"11590\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11553\" data-end=\"11590\"\u003eIndoor Unit Location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"11592\" data-end=\"11935\"\u003eThe indoor unit must be placed to effectively distribute air in the main room. The airflow of this model ranges between \u003cstrong data-start=\"11733\" data-end=\"11751\"\u003e383 and 647 CFM\u003c\/strong\u003e, which is powerful enough to cover a large area. A poor location can create a direct draft on occupants or leave some areas less comfortable.\u003c\/p\u003e\n\u003cp data-start=\"11937\" data-end=\"12343\"\u003eWe always analyze the shape of the room, obstacles, furniture, ceilings, stairs, load-bearing walls, and openings between rooms. In some Montreal homes, brick walls, plaster ceilings, or limited access can complicate the choice of location. Good planning avoids unnecessary piping runs and improves the aesthetic result.\u003c\/p\u003e\n\u003ch3 data-start=\"12345\" data-end=\"12386\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"12349\" data-end=\"12386\"\u003eOutdoor Unit Location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"12388\" data-end=\"12690\"\u003eThe outdoor unit must be installed on a stable base, with sufficient clearance to allow good air circulation. The indicated outdoor sound pressure level is \u003cstrong data-start=\"12574\" data-end=\"12586\"\u003e58 dB(A)\u003c\/strong\u003e, which must be considered in denser areas, especially in Montreal, Longueuil, or Laval.\u003c\/p\u003e\n\u003cp data-start=\"12692\" data-end=\"13023\"\u003eYou also need to consider snow, ice, roof water, and future access for maintenance. A poorly positioned outdoor unit can be exposed to snow accumulation or drainage issues. At AirGreen, we always recommend an installation that takes Quebec’s winter conditions into account.\u003c\/p\u003e\n\u003ch3 data-start=\"13025\" data-end=\"13056\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"13029\" data-end=\"13056\"\u003e1\/4 - 1\/2 inch Piping\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"13058\" data-end=\"13287\"\u003eThe ZE-18CB25 uses \u003cstrong data-start=\"13094\" data-end=\"13112\"\u003e1\/4 inch liquid\u003c\/strong\u003e and \u003cstrong data-start=\"13116\" data-end=\"13130\"\u003e1\/2 inch gas\u003c\/strong\u003e piping. This information is essential when replacing an old heat pump. You should never assume existing lines are compatible.\u003c\/p\u003e\n\u003cp data-start=\"13289\" data-end=\"13593\"\u003eWhen replacing, we check the diameter, condition of the lines, type of old refrigerant, length of the run, accessibility, and the possibility of cleanly replacing the lines. In many cases, replacing the piping is the best solution to ensure a durable installation.\u003c\/p\u003e\n\u003ch3 data-start=\"13595\" data-end=\"13638\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"13599\" data-end=\"13638\"\u003e208V \/ 230V Power Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"13640\" data-end=\"13914\"\u003eThis model operates on \u003cstrong data-start=\"13664\" data-end=\"13695\"\u003e208V \/ 230V, 60 Hz, 1 phase\u003c\/strong\u003e, with a \u003cstrong data-start=\"13705\" data-end=\"13722\"\u003e20.0 A MCA\u003c\/strong\u003e and a \u003cstrong data-start=\"13729\" data-end=\"13746\"\u003e20.0 A MOP\u003c\/strong\u003e. This means an appropriate power supply must be planned. The panel must be able to accommodate the necessary circuit, and the wire gauge must be compliant.\u003c\/p\u003e\n\u003cp data-start=\"13916\" data-end=\"14175\"\u003eThis check is especially important in older homes in Montreal, Longueuil, or Laval, where electrical panels may already be quite full. A realistic quote must always take this aspect into account before work begins.\u003c\/p\u003e\n\u003ch2 data-start=\"14177\" data-end=\"14214\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"14180\" data-end=\"14214\"\u003eBuilt-in comfort functions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"14216\" data-end=\"14335\"\u003eThe brochure presents several interesting features that enhance the daily use of the Zephyr ZE-18CB25.\u003c\/p\u003e\n\u003cp data-start=\"14337\" data-end=\"14360\"\u003eNotably included:\u003c\/p\u003e\n\u003cp data-start=\"14362\" data-end=\"14944\"\u003e• \u003cstrong data-start=\"14364\" data-end=\"14377\"\u003eNight mode\u003c\/strong\u003e\u003cbr data-start=\"14377\" data-end=\"14380\"\u003e• \u003cstrong data-start=\"14382\" data-end=\"14398\"\u003eSilent mode\u003c\/strong\u003e\u003cbr data-start=\"14398\" data-end=\"14401\"\u003e• \u003cstrong data-start=\"14403\" data-end=\"14417\"\u003eiFeel mode\u003c\/strong\u003e\u003cbr data-start=\"14417\" data-end=\"14420\"\u003e• \u003cstrong data-start=\"14422\" data-end=\"14442\"\u003eQuick start\u003c\/strong\u003e\u003cbr data-start=\"14442\" data-end=\"14445\"\u003e• \u003cstrong data-start=\"14447\" data-end=\"14465\"\u003e24-hour timer\u003c\/strong\u003e\u003cbr data-start=\"14465\" data-end=\"14468\"\u003e• \u003cstrong data-start=\"14470\" data-end=\"14492\"\u003eTwo-sided drain\u003c\/strong\u003e\u003cbr data-start=\"14492\" data-end=\"14495\"\u003e• \u003cstrong data-start=\"14497\" data-end=\"14521\"\u003eBase heating\u003c\/strong\u003e\u003cbr data-start=\"14521\" data-end=\"14524\"\u003e• \u003cstrong data-start=\"14526\" data-end=\"14554\"\u003eCompressor heating\u003c\/strong\u003e\u003cbr data-start=\"14554\" data-end=\"14557\"\u003e• \u003cstrong data-start=\"14559\" data-end=\"14601\"\u003eAuto-adaptive voltage technology\u003c\/strong\u003e\u003cbr data-start=\"14601\" data-end=\"14604\"\u003e• \u003cstrong data-start=\"14606\" data-end=\"14635\"\u003eFireproof electrical box\u003c\/strong\u003e\u003cbr data-start=\"14635\" data-end=\"14638\"\u003e• \u003cstrong data-start=\"14640\" data-end=\"14665\"\u003eAutomatic defrost\u003c\/strong\u003e\u003cbr data-start=\"14665\" data-end=\"14668\"\u003e• \u003cstrong data-start=\"14670\" data-end=\"14695\"\u003eAutomatic cleaning\u003c\/strong\u003e\u003cbr data-start=\"14695\" data-end=\"14698\"\u003e• \u003cstrong data-start=\"14700\" data-end=\"14718\"\u003eTurbo function\u003c\/strong\u003e\u003cbr data-start=\"14718\" data-end=\"14721\"\u003e• \u003cstrong data-start=\"14723\" data-end=\"14752\"\u003eLED wireless remote control\u003c\/strong\u003e\u003cbr data-start=\"14752\" data-end=\"14755\"\u003e• \u003cstrong data-start=\"14757\" data-end=\"14776\"\u003eLED dimmer\u003c\/strong\u003e\u003cbr data-start=\"14776\" data-end=\"14779\"\u003e• \u003cstrong data-start=\"14781\" data-end=\"14817\"\u003eDiffuser position memory\u003c\/strong\u003e\u003cbr data-start=\"14817\" data-end=\"14820\"\u003e• \u003cstrong data-start=\"14822\" data-end=\"14862\"\u003e4D mode with automatic oscillation\u003c\/strong\u003e\u003cbr data-start=\"14862\" data-end=\"14865\"\u003e• \u003cstrong data-start=\"14867\" data-end=\"14907\"\u003e5 indoor fan speeds\u003c\/strong\u003e\u003cbr data-start=\"14907\" data-end=\"14910\"\u003e• \u003cstrong data-start=\"14912\" data-end=\"14944\"\u003eAutomatic heating at 8 °C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"14946\" data-end=\"15172\"\u003eThe \u003cstrong data-start=\"14949\" data-end=\"14960\"\u003e4D mode\u003c\/strong\u003e and \u003cstrong data-start=\"14966\" data-end=\"14993\"\u003eautomatic oscillation\u003c\/strong\u003e are particularly useful for better distributing air in the room. The goal is to reduce cold or hot spots and achieve a more balanced temperature.\u003c\/p\u003e\n\u003cp data-start=\"15174\" data-end=\"15539\"\u003eVariable frequency technology also allows the heat pump to adjust its power in real time. This helps limit temperature fluctuations and improve overall comfort. \u003cstrong data-start=\"15368\" data-end=\"15539\"\u003eA well-installed Inverter device can operate more smoothly, longer, and more efficiently than a traditional system that constantly starts and stops.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"15541\" data-end=\"15607\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"15544\" data-end=\"15607\"\u003eHVAC Maintenance: maintaining performance year after year\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"15609\" data-end=\"15792\"\u003eEven a good heat pump must be properly maintained. A well-installed Zephyr ZE-18CB25 will deliver better results if the owner follows some good practices.\u003c\/p\u003e\n\u003cp data-start=\"15794\" data-end=\"15823\"\u003eWe especially recommend:\u003c\/p\u003e\n\u003cp data-start=\"15825\" data-end=\"16308\"\u003e• \u003cstrong data-start=\"15827\" data-end=\"15887\"\u003eregularly clean the indoor unit filters\u003c\/strong\u003e;\u003cbr data-start=\"15888\" data-end=\"15891\"\u003e• \u003cstrong data-start=\"15893\" data-end=\"15946\"\u003eensure the condensation drain remains free\u003c\/strong\u003e;\u003cbr data-start=\"15947\" data-end=\"15950\"\u003e• \u003cstrong data-start=\"15952\" data-end=\"16018\"\u003ekeep the outdoor unit clear of snow, leaves, and debris\u003c\/strong\u003e;\u003cbr data-start=\"16019\" data-end=\"16022\"\u003e• \u003cstrong data-start=\"16024\" data-end=\"16100\"\u003eavoid blocking the indoor air outlet with furniture or curtains\u003c\/strong\u003e;\u003cbr data-start=\"16101\" data-end=\"16104\"\u003e• \u003cstrong data-start=\"16106\" data-end=\"16168\"\u003ehave the device inspected if unusual noise appears\u003c\/strong\u003e;\u003cbr data-start=\"16169\" data-end=\"16172\"\u003e• \u003cstrong data-start=\"16174\" data-end=\"16247\"\u003eschedule professional cleaning when the heat exchanger is dirty\u003c\/strong\u003e;\u003cbr data-start=\"16248\" data-end=\"16251\"\u003e• \u003cstrong data-start=\"16253\" data-end=\"16307\"\u003echeck the general condition before extreme seasons\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"16310\" data-end=\"16542\"\u003eFeatures like \u003cstrong data-start=\"16333\" data-end=\"16358\"\u003eautomatic cleaning\u003c\/strong\u003e or \u003cstrong data-start=\"16365\" data-end=\"16390\"\u003eautomatic defrosting\u003c\/strong\u003e are useful, but they don’t replace serious maintenance. A clean device breathes better, consumes less, heats better, and lasts longer.\u003c\/p\u003e\n\u003ch2 data-start=\"16544\" data-end=\"16610\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"16547\" data-end=\"16610\"\u003eMistakes to avoid before buying an 18,000 BTU heat pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"16612\" data-end=\"16750\"\u003eThe most costly mistakes don’t always come from the brand choice. They often come from a poor project assessment.\u003c\/p\u003e\n\u003cp data-start=\"16752\" data-end=\"16803\"\u003eHere are the most common mistakes we see:\u003c\/p\u003e\n\u003cp data-start=\"16805\" data-end=\"17380\"\u003e• choosing a \u003cstrong data-start=\"16819\" data-end=\"16833\"\u003e18,000 BTU\u003c\/strong\u003e unit without analyzing the actual load;\u003cbr data-start=\"16865\" data-end=\"16868\"\u003e• neglecting the impact of the indoor location;\u003cbr data-start=\"16915\" data-end=\"16918\"\u003e• forgetting electrical verification;\u003cbr data-start=\"16955\" data-end=\"16958\"\u003e• assuming old refrigerant lines are compatible;\u003cbr data-start=\"17025\" data-end=\"17028\"\u003e• installing the outdoor unit too close to a wall or fence;\u003cbr data-start=\"17095\" data-end=\"17098\"\u003e• ignoring snow accumulation in winter;\u003cbr data-start=\"17141\" data-end=\"17144\"\u003e• choosing the location just to hide the pipes;\u003cbr data-start=\"17201\" data-end=\"17204\"\u003e• not planning for future maintenance access;\u003cbr data-start=\"17252\" data-end=\"17255\"\u003e• comparing only the price without comparing the installation;\u003cbr data-start=\"17313\" data-end=\"17316\"\u003e• promising a subsidy without verifying exact eligibility.\u003c\/p\u003e\n\u003cp data-start=\"17382\" data-end=\"17572\"\u003eAt AirGreen, our approach is to clarify these points before installation. \u003cstrong data-start=\"17466\" data-end=\"17572\"\u003eA good heat pump must be chosen for the actual building, not just based on a technical sheet.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"17574\" data-end=\"17641\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"17577\" data-end=\"17641\"\u003eWhy choose AirGreen to install the Zephyr ZE-18CB25\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"17643\" data-end=\"17923\"\u003eAirGreen is a company specialized in \u003cstrong data-start=\"17686\" data-end=\"17694\"\u003eHVAC\u003c\/strong\u003e that installs, maintains, and repairs air conditioning, heating, and heat pump systems in Greater Montreal. We regularly operate in \u003cstrong data-start=\"17844\" data-end=\"17922\"\u003eMontreal, Laval, Longueuil, on the South Shore, the North Shore, and in Montérégie\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"17925\" data-end=\"17975\"\u003eBy choosing AirGreen, customers benefit from:\u003c\/p\u003e\n\u003cp data-start=\"17977\" data-end=\"18461\"\u003e• \u003cstrong data-start=\"17979\" data-end=\"18024\"\u003ea clear evaluation before work begins\u003c\/strong\u003e;\u003cbr data-start=\"18025\" data-end=\"18028\"\u003e• \u003cstrong data-start=\"18030\" data-end=\"18074\"\u003ea device choice adapted to the building\u003c\/strong\u003e;\u003cbr data-start=\"18075\" data-end=\"18078\"\u003e• \u003cstrong data-start=\"18080\" data-end=\"18136\"\u003ean installation compliant with technical requirements\u003c\/strong\u003e;\u003cbr data-start=\"18137\" data-end=\"18140\"\u003e• \u003cstrong data-start=\"18142\" data-end=\"18184\"\u003ea thorough electrical inspection\u003c\/strong\u003e;\u003cbr data-start=\"18185\" data-end=\"18188\"\u003e• \u003cstrong data-start=\"18190\" data-end=\"18247\"\u003ean honest explanation of winter performance\u003c\/strong\u003e;\u003cbr data-start=\"18248\" data-end=\"18251\"\u003e• \u003cstrong data-start=\"18253\" data-end=\"18291\"\u003ea structured after-sales service\u003c\/strong\u003e;\u003cbr data-start=\"18292\" data-end=\"18295\"\u003e• \u003cstrong data-start=\"18297\" data-end=\"18373\"\u003ea team experienced with wall-mounted, central, and multi-zone installations\u003c\/strong\u003e;\u003cbr data-start=\"18374\" data-end=\"18377\"\u003e• \u003cstrong data-start=\"18379\" data-end=\"18460\"\u003esupport to understand warranties, options, and maintenance\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"18463\" data-end=\"18717\"\u003eWe know a heat pump is a significant investment. Our goal is for the customer to understand what they are buying, why this model is recommended, how it will be installed, and how to use it to achieve the best possible performance.\u003c\/p\u003e\n\u003ch2 data-start=\"18719\" data-end=\"18805\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"18722\" data-end=\"18805\"\u003eA reliable HVAC solution for homes and small businesses in Greater Montreal\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"18807\" data-end=\"19255\"\u003eThe \u003cstrong data-start=\"18810\" data-end=\"18866\"\u003eZephyr ZE-18CB25 R454B 18,000 BTU wall-mounted heat pump\u003c\/strong\u003e is an attractive solution for customers looking for a high-performance, modern heat pump suited to Quebec winters. With its \u003cstrong data-start=\"19009\" data-end=\"19042\"\u003eoperation down to -30 °C\u003c\/strong\u003e, \u003cstrong data-start=\"19048\" data-end=\"19069\"\u003eR454B refrigerant\u003c\/strong\u003e, \u003cstrong data-start=\"19075\" data-end=\"19092\"\u003eSEER2 of 21.0\u003c\/strong\u003e, \u003cstrong data-start=\"19111\" data-end=\"19131\"\u003eENERGY STAR V6.1 certification\u003c\/strong\u003e, high airflow, and many comfort features, it meets various residential and commercial needs.\u003c\/p\u003e\n\u003cp data-start=\"19257\" data-end=\"19531\"\u003eHowever, it requires professional installation. The piping \u003cstrong data-start=\"19328\" data-end=\"19344\"\u003e1\/4 - 1\/2 inch\u003c\/strong\u003e, power supply \u003cstrong data-start=\"19361\" data-end=\"19376\"\u003e208V \/ 230V\u003c\/strong\u003e, \u003cstrong data-start=\"19381\" data-end=\"19396\"\u003e20 A MCA\u003c\/strong\u003e, \u003cstrong data-start=\"19401\" data-end=\"19416\"\u003e20 A MOP\u003c\/strong\u003e, outdoor clearances, drainage, and wall location must be verified before confirming the project.\u003c\/p\u003e\n\u003cp data-start=\"19533\" data-end=\"19914\"\u003eTo get a clear quote, compare this model with other wall-mounted heat pumps, check eligibility for available programs, or schedule an installation in \u003cstrong data-start=\"19708\" data-end=\"19771\"\u003eMontreal, Laval, Longueuil, on the South Shore or the North Shore\u003c\/strong\u003e, contact AirGreen. Our team will help you choose the right HVAC solution based on your building, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665926242596,"sku":"ZE-18CB25I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRCB25R454BGRANDMONTREAL_b84904d8-1bf5-4e54-88bc-7edab0227139.png?v=1783695908"},{"product_id":"thermopompe-murale-zephyr-cb25-r454b-24000-btu-montreal-laval-rive-sud","title":"ZEPHYR CB25 R454B Wall Heat Pump | 24000 BTU | Montreal, Laval, South Shore","description":"\u003ch1 data-start=\"0\" data-end=\"65\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2\" data-end=\"65\"\u003eZephyr CB25 R454B ZE-24CB25 Wall-Mounted Heat Pump – 24,000 BTU\u003c\/strong\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"67\" data-end=\"194\"\u003eA 24,000 BTU wall-mounted heat pump designed for large spaces, heating down to -30 °C, and stable daily comfort\u003c\/p\u003e\n\u003cp data-start=\"196\" data-end=\"646\"\u003eThe \u003cstrong data-start=\"199\" data-end=\"249\"\u003eZephyr CB25 R454B ZE-24CB25 Wall-Mounted Heat Pump\u003c\/strong\u003e is aimed at owners looking for a powerful, modern HVAC solution well adapted to the realities of the Quebec climate. With its capacity of \u003cstrong data-start=\"401\" data-end=\"432\"\u003e24,000 BTU in cooling\u003c\/strong\u003e and \u003cstrong data-start=\"436\" data-end=\"472\"\u003e24,000 BTU in heating at 8.3 °C\u003c\/strong\u003e, this model is designed for large residential spaces, open areas, spacious condos, light commercial spaces, or zones difficult to balance in temperature.\u003c\/p\u003e\n\u003cp data-start=\"648\" data-end=\"1142\"\u003eAt AirGreen, we recommend this type of device when a customer needs a wall-mounted heat pump capable of providing a good power reserve while maintaining a pleasant and more consistent indoor temperature. Whether in \u003cstrong data-start=\"890\" data-end=\"957\"\u003eMontreal, Laval, Longueuil, on the South Shore or the North Shore\u003c\/strong\u003e, a machine of this capacity must be chosen carefully: it can offer excellent comfort, but only if it is properly sized, well positioned, and correctly installed.\u003c\/p\u003e\n\u003cp data-start=\"1144\" data-end=\"1653\"\u003eThe \u003cstrong data-start=\"1153\" data-end=\"1168\"\u003eZephyr CB25\u003c\/strong\u003e series stands out for several important features: its refrigerant \u003cstrong data-start=\"1234\" data-end=\"1243\"\u003eR454B\u003c\/strong\u003e, its \u003cstrong data-start=\"1262\" data-end=\"1282\"\u003eEnergy Star V6.1\u003c\/strong\u003e certification, its heating operation down to \u003cstrong data-start=\"1324\" data-end=\"1334\"\u003e-30 °C\u003c\/strong\u003e, its variable frequency technology, its 4D mode, its high airflow, and its solid technical specifications for a 24,000 BTU wall-mounted heat pump. The technical data below come from the provided Zephyr CB25 brochure, notably the datasheet for the \u003cstrong data-start=\"1601\" data-end=\"1614\"\u003eZE-24CB25\u003c\/strong\u003e model.\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1658\" data-end=\"1680\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"2453\" data-end=\"2523\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2456\" data-end=\"2523\"\u003e1. A 24,000 BTU wall-mounted heat pump for demanding projects\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2525\" data-end=\"2929\"\u003eThe \u003cstrong data-start=\"2528\" data-end=\"2559\"\u003eZephyr CB25 R454B ZE-24CB25\u003c\/strong\u003e is a wall-mounted heat pump designed to meet greater needs than a simple closed room. With a capacity of \u003cstrong data-start=\"2687\" data-end=\"2701\"\u003e24,000 BTU\u003c\/strong\u003e, it can suit a large open area, a ground floor, a light commercial space, a large living room, a room with a higher ceiling, or a zone where heating and cooling loads are more significant.\u003c\/p\u003e\n\u003cp data-start=\"2931\" data-end=\"3413\"\u003eHowever, at AirGreen, we always emphasize one essential point: \u003cstrong data-start=\"3006\" data-end=\"3092\"\u003e24,000 BTU does not automatically mean “best choice” for every project\u003c\/strong\u003e. An overly powerful heat pump can reach the temperature too quickly in summer, reduce dehumidification time, and create uneven comfort. Conversely, an undersized unit will have to run almost continuously and might struggle during periods of intense cold or prolonged heat.\u003c\/p\u003e\n\u003cp data-start=\"3415\" data-end=\"3779\"\u003eThat’s why we always analyze the area, insulation, ceiling height, window orientation, sunlight exposure, room layout, available clearances, and the location of the outdoor unit. A heat pump like the \u003cstrong data-start=\"3673\" data-end=\"3686\"\u003eZE-24CB25\u003c\/strong\u003e can offer excellent performance, but it must be smartly integrated into the building.\u003c\/p\u003e\n\u003ch2 data-start=\"3781\" data-end=\"3847\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3784\" data-end=\"3847\"\u003e2. Important technical specifications of the ZE-24CB25\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3849\" data-end=\"3954\"\u003eHere are the main details to remember for the \u003cstrong data-start=\"3902\" data-end=\"3952\"\u003eZephyr CB25 R454B ZE-24CB25 Wall-Mounted Heat Pump\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp data-start=\"3956\" data-end=\"5674\"\u003e• \u003cstrong data-start=\"3958\" data-end=\"3977\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"3977\" data-end=\"3980\"\u003e• \u003cstrong data-start=\"3982\" data-end=\"3998\"\u003eSeries: CB25\u003c\/strong\u003e\u003cbr data-start=\"3998\" data-end=\"4001\"\u003e• \u003cstrong data-start=\"4003\" data-end=\"4025\"\u003eModel: ZE-24CB25\u003c\/strong\u003e\u003cbr data-start=\"4025\" data-end=\"4028\"\u003e• \u003cstrong data-start=\"4030\" data-end=\"4059\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"4059\" data-end=\"4062\"\u003e• \u003cstrong data-start=\"4064\" data-end=\"4087\"\u003eRefrigerant: R454B\u003c\/strong\u003e\u003cbr data-start=\"4087\" data-end=\"4090\"\u003e• \u003cstrong data-start=\"4092\" data-end=\"4146\"\u003eCooling capacity at 35 °C: 24,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4146\" data-end=\"4149\"\u003e• \u003cstrong data-start=\"4151\" data-end=\"4200\"\u003eHeating capacity at 8.3 °C: 24,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4200\" data-end=\"4203\"\u003e• \u003cstrong data-start=\"4205\" data-end=\"4221\"\u003eSEER2: 22.5\u003c\/strong\u003e\u003cbr data-start=\"4221\" data-end=\"4224\"\u003e• \u003cstrong data-start=\"4226\" data-end=\"4244\"\u003eHSPF2 IV: 9.5\u003c\/strong\u003e\u003cbr data-start=\"4244\" data-end=\"4247\"\u003e• \u003cstrong data-start=\"4249\" data-end=\"4265\"\u003eEER2: 12.25\u003c\/strong\u003e\u003cbr data-start=\"4265\" data-end=\"4268\"\u003e• \u003cstrong data-start=\"4270\" data-end=\"4307\"\u003eHeating COP at 8.3 °C: 3.35 W\/W\u003c\/strong\u003e\u003cbr data-start=\"4307\" data-end=\"4310\"\u003e• \u003cstrong data-start=\"4312\" data-end=\"4338\"\u003eCOP at -15 °C: 2.0 W\/W\u003c\/strong\u003e\u003cbr data-start=\"4338\" data-end=\"4341\"\u003e• \u003cstrong data-start=\"4343\" data-end=\"4389\"\u003eNominal heating at -8.3 °C: 22,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4389\" data-end=\"4392\"\u003e• \u003cstrong data-start=\"4394\" data-end=\"4439\"\u003eMaximum heating at -15 °C: 19,200 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4439\" data-end=\"4442\"\u003e• \u003cstrong data-start=\"4444\" data-end=\"4489\"\u003eMaximum heating at -20 °C: 14,100 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4489\" data-end=\"4492\"\u003e• \u003cstrong data-start=\"4494\" data-end=\"4539\"\u003eMaximum heating at -25 °C: 11,700 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4539\" data-end=\"4542\"\u003e• \u003cstrong data-start=\"4544\" data-end=\"4570\"\u003eEnergy Star V6.1: yes\u003c\/strong\u003e\u003cbr data-start=\"4570\" data-end=\"4573\"\u003e• \u003cstrong data-start=\"4575\" data-end=\"4616\"\u003eIndoor air flow: 441 to 706 CFM\u003c\/strong\u003e\u003cbr data-start=\"4616\" data-end=\"4619\"\u003e• \u003cstrong data-start=\"4621\" data-end=\"4682\"\u003eIndoor sound pressure: 50 \/ 48 \/ 43 \/ 41 \/ 39 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"4682\" data-end=\"4685\"\u003e• \u003cstrong data-start=\"4687\" data-end=\"4728\"\u003eOutdoor sound pressure: 61 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"4728\" data-end=\"4731\"\u003e• \u003cstrong data-start=\"4733\" data-end=\"4773\"\u003eVoltage: 208V \/ 230V, 60Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"4773\" data-end=\"4776\"\u003e• \u003cstrong data-start=\"4778\" data-end=\"4824\"\u003eNominal cooling current: 8.7 A\u003c\/strong\u003e\u003cbr data-start=\"4824\" data-end=\"4827\"\u003e• \u003cstrong data-start=\"4829\" data-end=\"4869\"\u003eNominal heating current: 9.3 A\u003c\/strong\u003e\u003cbr data-start=\"4869\" data-end=\"4872\"\u003e• \u003cstrong data-start=\"4874\" data-end=\"4888\"\u003eMCA: 22 A\u003c\/strong\u003e\u003cbr data-start=\"4888\" data-end=\"4891\"\u003e• \u003cstrong data-start=\"4893\" data-end=\"4907\"\u003eMOP: 25 A\u003c\/strong\u003e\u003cbr data-start=\"4907\" data-end=\"4910\"\u003e• \u003cstrong data-start=\"4912\" data-end=\"4975\"\u003eRequired communication wire: 4\/14 copper multi-strand 600V\u003c\/strong\u003e\u003cbr data-start=\"4975\" data-end=\"4978\"\u003e• \u003cstrong data-start=\"4980\" data-end=\"5011\"\u003eLiquid piping: 3\/8 in\u003c\/strong\u003e\u003cbr data-start=\"5011\" data-end=\"5014\"\u003e• \u003cstrong data-start=\"5016\" data-end=\"5043\"\u003eGas piping: 5\/8 in\u003c\/strong\u003e\u003cbr data-start=\"5043\" data-end=\"5046\"\u003e• \u003cstrong data-start=\"5048\" data-end=\"5095\"\u003eMinimum-maximum piping length: 10 to 98 ft\u003c\/strong\u003e\u003cbr data-start=\"5095\" data-end=\"5098\"\u003e• \u003cstrong data-start=\"5100\" data-end=\"5134\"\u003eMaximum elevation difference: 50 ft\u003c\/strong\u003e\u003cbr data-start=\"5134\" data-end=\"5137\"\u003e• \u003cstrong data-start=\"5139\" data-end=\"5172\"\u003ePrecharge length: 25 ft\u003c\/strong\u003e\u003cbr data-start=\"5172\" data-end=\"5175\"\u003e• \u003cstrong data-start=\"5177\" data-end=\"5207\"\u003eCompressor: GMCC rotary\u003c\/strong\u003e\u003cbr data-start=\"5207\" data-end=\"5210\"\u003e• \u003cstrong data-start=\"5212\" data-end=\"5243\"\u003eExpansion device: EEV\u003c\/strong\u003e\u003cbr data-start=\"5243\" data-end=\"5246\"\u003e• \u003cstrong data-start=\"5248\" data-end=\"5277\"\u003eIndoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"5277\" data-end=\"5280\"\u003e• \u003cstrong data-start=\"5282\" data-end=\"5311\"\u003eOutdoor DC motor: yes\u003c\/strong\u003e\u003cbr data-start=\"5311\" data-end=\"5314\"\u003e• \u003cstrong data-start=\"5316\" data-end=\"5383\"\u003eIndoor unit dimensions L x D x H: 42.06 x 9.06 x 12.63 in\u003c\/strong\u003e\u003cbr data-start=\"5383\" data-end=\"5386\"\u003e• \u003cstrong data-start=\"5388\" data-end=\"5456\"\u003eOutdoor unit dimensions L x D x H: 35.38 x 13.50 x 29.50 in\u003c\/strong\u003e\u003cbr data-start=\"5456\" data-end=\"5459\"\u003e• \u003cstrong data-start=\"5461\" data-end=\"5506\"\u003eCooling range: -15 °C to 48 °C\u003c\/strong\u003e\u003cbr data-start=\"5506\" data-end=\"5509\"\u003e• \u003cstrong data-start=\"5511\" data-end=\"5550\"\u003eHeating range: -30 °C to 24 °C\u003c\/strong\u003e\u003cbr data-start=\"5550\" data-end=\"5553\" data-is-only-node=\"\"\u003e• \u003cstrong data-start=\"5555\" data-end=\"5598\"\u003eZephyr basic warranty: 10 years parts\u003c\/strong\u003e\u003cbr data-start=\"5598\" data-end=\"5601\"\u003e• \u003cstrong data-start=\"5603\" data-end=\"5674\"\u003eLabor warranty: available depending on the offer and distributor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5676\" data-end=\"5971\"\u003eAn important point: the brochure states that the series can reach \u003cstrong data-start=\"5745\" data-end=\"5776\"\u003eup to 25 SEER2 \/ 11 HSPF2\u003c\/strong\u003e, but for the specific model \u003cstrong data-start=\"5805\" data-end=\"5818\"\u003eZE-24CB25\u003c\/strong\u003e, the indicated values are \u003cstrong data-start=\"5847\" data-end=\"5861\"\u003e22.5 SEER2\u003c\/strong\u003e and \u003cstrong data-start=\"5865\" data-end=\"5878\"\u003e9.5 HSPF2\u003c\/strong\u003e. This is a crucial distinction, as performance varies depending on the unit’s capacity.\u003c\/p\u003e\n\u003ch2 data-start=\"5973\" data-end=\"6057\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"5976\" data-end=\"6057\"\u003e3. The R454B refrigerant: a new generation for HVAC installations\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"6059\" data-end=\"6404\"\u003eThe \u003cstrong data-start=\"6069\" data-end=\"6082\"\u003eZE-24CB25\u003c\/strong\u003e model operates with \u003cstrong data-start=\"6097\" data-end=\"6118\"\u003eR454B refrigerant\u003c\/strong\u003e, a new generation refrigerant increasingly used in modern HVAC equipment. For a customer, the type of refrigerant may seem secondary, but it directly influences the design of the unit, installation practices, and technical requirements.\u003c\/p\u003e\n\u003cp data-start=\"6406\" data-end=\"6728\"\u003eWith the \u003cstrong data-start=\"6414\" data-end=\"6423\"\u003eR454B\u003c\/strong\u003e, the installation must be carried out with precision. Pipe lengths, fittings, vacuum pulling, leak tests, adherence to line diameters, and electrical compliance become even more important. A modern heat pump does not tolerate a sloppy installation.\u003c\/p\u003e\n\u003cp data-start=\"6730\" data-end=\"7031\"\u003eAt AirGreen, we pay close attention to these details, especially when it comes to a high-capacity unit like a \u003cstrong data-start=\"6868\" data-end=\"6882\"\u003e24,000 BTU\u003c\/strong\u003e. Poor installation can reduce performance, increase noise, cause drainage problems, or harm the compressor’s durability.\u003c\/p\u003e\n\u003ch2 data-start=\"7033\" data-end=\"7100\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"7036\" data-end=\"7100\"\u003e4. Heating down to -30 °C: what this means in Quebec\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"7102\" data-end=\"7486\"\u003eThe brochure states that the Zephyr heat pump can provide optimal heating down to an outdoor temperature of \u003cstrong data-start=\"7220\" data-end=\"7230\"\u003e-30 °C\u003c\/strong\u003e. For Quebec, this is an important point. Winters in Montreal, Laval, Longueuil, on the South Shore and North Shore can bring long periods of cold, and a wall-mounted heat pump must be able to operate in tough conditions.\u003c\/p\u003e\n\u003cp data-start=\"7488\" data-end=\"7560\"\u003eHowever, it is important to understand the numbers well. The \u003cstrong data-start=\"7539\" data-end=\"7552\"\u003eZE-24CB25\u003c\/strong\u003e offers:\u003c\/p\u003e\n\u003cp data-start=\"7562\" data-end=\"7680\"\u003e• \u003cstrong data-start=\"7564\" data-end=\"7590\"\u003e22,000 BTU\/h at -8.3 °C\u003c\/strong\u003e\u003cbr data-start=\"7590\" data-end=\"7593\"\u003e• \u003cstrong data-start=\"7595\" data-end=\"7620\"\u003e19,200 BTU\/h at -15 °C\u003c\/strong\u003e\u003cbr data-start=\"7620\" data-end=\"7623\"\u003e• \u003cstrong data-start=\"7625\" data-end=\"7650\"\u003e14,100 BTU\/h at -20 °C\u003c\/strong\u003e\u003cbr data-start=\"7650\" data-end=\"7653\"\u003e• \u003cstrong data-start=\"7655\" data-end=\"7680\"\u003e11,700 BTU\/h at -25 °C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7682\" data-end=\"8120\"\u003eThese values show that the unit maintains a good capacity at low temperatures, but like all heat pumps, its capacity decreases as the cold intensifies. In a well-insulated house, this performance can cover a large part of the heating needs. In an older house, with many windows or exposed to wind, supplementary heating may still be necessary on the coldest days.\u003c\/p\u003e\n\u003cp data-start=\"8122\" data-end=\"8383\"\u003eAt AirGreen, we always explain this reality before installation. \u003cstrong data-start=\"8198\" data-end=\"8317\"\u003eA high-performance wall-mounted heat pump can significantly reduce the use of traditional electric heating\u003c\/strong\u003e, but it must be chosen according to the actual needs of the building.\u003c\/p\u003e\n\u003ch2 data-start=\"8385\" data-end=\"8471\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"8388\" data-end=\"8471\"\u003e5. Indoor comfort: 4D mode, automatic oscillation, and Inverter technology\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"8473\" data-end=\"8812\"\u003eThe brochure highlights several features designed to improve daily comfort. The \u003cstrong data-start=\"8567\" data-end=\"8580\"\u003eZE-24CB25\u003c\/strong\u003e uses variable frequency technology, often called \u003cstrong data-start=\"8643\" data-end=\"8655\"\u003eInverter\u003c\/strong\u003e, which allows the heat pump to adjust its power in real time. This helps limit temperature fluctuations and reduce energy consumption.\u003c\/p\u003e\n\u003cp data-start=\"8814\" data-end=\"9204\"\u003eThe \u003cstrong data-start=\"8817\" data-end=\"8828\"\u003e4D mode\u003c\/strong\u003e and \u003cstrong data-start=\"8834\" data-end=\"8861\"\u003eautomatic oscillation\u003c\/strong\u003e help distribute air better throughout the room. This feature is especially useful for large spaces, as it helps avoid cold spots or overly warm areas. In an open area, good air movement can make a big difference between simply reaching a temperature and truly comfortable conditions.\u003c\/p\u003e\n\u003cp data-start=\"9206\" data-end=\"9265\"\u003eThe brochure also mentions several practical features:\u003c\/p\u003e\n\u003cp data-start=\"9267\" data-end=\"9853\"\u003e• \u003cstrong data-start=\"9269\" data-end=\"9282\"\u003eNight mode\u003c\/strong\u003e\u003cbr data-start=\"9282\" data-end=\"9285\"\u003e• \u003cstrong data-start=\"9287\" data-end=\"9303\"\u003eSilent mode\u003c\/strong\u003e\u003cbr data-start=\"9303\" data-end=\"9306\"\u003e• \u003cstrong data-start=\"9308\" data-end=\"9322\"\u003eiFeel mode\u003c\/strong\u003e\u003cbr data-start=\"9322\" data-end=\"9325\"\u003e• \u003cstrong data-start=\"9327\" data-end=\"9347\"\u003eQuick start\u003c\/strong\u003e\u003cbr data-start=\"9347\" data-end=\"9350\"\u003e• \u003cstrong data-start=\"9352\" data-end=\"9369\"\u003e24-hour timer\u003c\/strong\u003e\u003cbr data-start=\"9369\" data-end=\"9372\"\u003e• \u003cstrong data-start=\"9374\" data-end=\"9399\"\u003eAutomatic defrost\u003c\/strong\u003e\u003cbr data-start=\"9399\" data-end=\"9402\"\u003e• \u003cstrong data-start=\"9404\" data-end=\"9429\"\u003eAutomatic cleaning\u003c\/strong\u003e\u003cbr data-start=\"9429\" data-end=\"9432\"\u003e• \u003cstrong data-start=\"9434\" data-end=\"9452\"\u003eTurbo function\u003c\/strong\u003e\u003cbr data-start=\"9452\" data-end=\"9455\"\u003e• \u003cstrong data-start=\"9457\" data-end=\"9486\"\u003eWireless LED remote control\u003c\/strong\u003e\u003cbr data-start=\"9486\" data-end=\"9489\"\u003e• \u003cstrong data-start=\"9491\" data-end=\"9510\"\u003eLED dimmer\u003c\/strong\u003e\u003cbr data-start=\"9510\" data-end=\"9513\"\u003e• \u003cstrong data-start=\"9515\" data-end=\"9555\"\u003e5 indoor fan speeds\u003c\/strong\u003e\u003cbr data-start=\"9555\" data-end=\"9558\"\u003e• \u003cstrong data-start=\"9560\" data-end=\"9596\"\u003eDiffuser position memory\u003c\/strong\u003e\u003cbr data-start=\"9596\" data-end=\"9599\"\u003e• \u003cstrong data-start=\"9601\" data-end=\"9639\"\u003eAutomatic heating 8 °C \/ 46 °F\u003c\/strong\u003e\u003cbr data-start=\"9639\" data-end=\"9642\"\u003e• \u003cstrong data-start=\"9644\" data-end=\"9666\"\u003eTwo-sided drain\u003c\/strong\u003e\u003cbr data-start=\"9666\" data-end=\"9669\"\u003e• \u003cstrong data-start=\"9671\" data-end=\"9699\"\u003eReversible drain pipe\u003c\/strong\u003e\u003cbr data-start=\"9699\" data-end=\"9702\"\u003e• \u003cstrong data-start=\"9704\" data-end=\"9739\"\u003eOutdoor base heating\u003c\/strong\u003e\u003cbr data-start=\"9739\" data-end=\"9742\"\u003e• \u003cstrong data-start=\"9744\" data-end=\"9772\"\u003eCompressor heating\u003c\/strong\u003e\u003cbr data-start=\"9772\" data-end=\"9775\"\u003e• \u003cstrong data-start=\"9777\" data-end=\"9806\"\u003eFireproof electrical box\u003c\/strong\u003e\u003cbr data-start=\"9806\" data-end=\"9809\"\u003e• \u003cstrong data-start=\"9811\" data-end=\"9853\"\u003eAuto-adaptive voltage technology\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"9855\" data-end=\"10112\"\u003eThese features do not replace a good installation, but they improve the user experience. A customer can better control comfort, reduce drafts, improve air distribution, and adjust operation according to the season.\u003c\/p\u003e\n\u003ch2 data-start=\"10114\" data-end=\"10189\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10117\" data-end=\"10189\"\u003e6. Installation: technical details to verify before work\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"10191\" data-end=\"10435\"\u003eA \u003cstrong data-start=\"10217\" data-end=\"10231\"\u003e24,000 BTU\u003c\/strong\u003e wall-mounted heat pump is not installed like a small 9,000 or 12,000 BTU unit. The \u003cstrong data-start=\"10300\" data-end=\"10313\"\u003eZE-24CB25\u003c\/strong\u003e requires serious planning, especially due to its capacity, electrical supply, and piping.\u003c\/p\u003e\n\u003ch3 data-start=\"10437\" data-end=\"10478\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10441\" data-end=\"10478\"\u003eIndoor unit location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"10480\" data-end=\"10756\"\u003eThe indoor unit measures approximately \u003cstrong data-start=\"10514\" data-end=\"10541\"\u003e42.06 x 9.06 x 12.63 in\u003c\/strong\u003e in L x D x H format. It is therefore wider than a small wall unit. You need to plan for a sufficiently clear wall, a good installation height, and an orientation that allows air to circulate efficiently.\u003c\/p\u003e\n\u003cp data-start=\"10758\" data-end=\"11185\"\u003eIn homes in Montreal or Longueuil, we often encounter constraints such as brick walls, plaster ceilings, narrow partitions, nearby windows, or exposed beams. In Laval, on the North Shore or South Shore, large open spaces sometimes allow for better air distribution, but it is still important to avoid blowing air directly on occupants for long periods.\u003c\/p\u003e\n\u003ch3 data-start=\"11187\" data-end=\"11228\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11191\" data-end=\"11228\"\u003eOutdoor Unit Location\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"11230\" data-end=\"11529\"\u003eThe outdoor unit measures approximately \u003cstrong data-start=\"11264\" data-end=\"11292\"\u003e35.38 x 13.50 x 29.50 in\u003c\/strong\u003e in L x D x H format. It must be installed in a stable, accessible, and well-ventilated location. The indicated outdoor noise level is \u003cstrong data-start=\"11433\" data-end=\"11445\"\u003e61 dB(A)\u003c\/strong\u003e, which should be considered in denser areas or near neighbors.\u003c\/p\u003e\n\u003cp data-start=\"11531\" data-end=\"11818\"\u003eThe outdoor unit must also be protected against snow accumulation, roof water, ice, and obstacles that can block airflow. Poor outdoor placement can reduce performance, increase defrost cycles, and complicate maintenance.\u003c\/p\u003e\n\u003ch3 data-start=\"11820\" data-end=\"11851\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11824\" data-end=\"11851\"\u003e3\/8 - 5\/8 in Piping\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"11853\" data-end=\"12045\"\u003eThe \u003cstrong data-start=\"11856\" data-end=\"11869\"\u003eZE-24CB25\u003c\/strong\u003e uses a liquid line of \u003cstrong data-start=\"11904\" data-end=\"11914\"\u003e3\/8 in\u003c\/strong\u003e and a gas line of \u003cstrong data-start=\"11940\" data-end=\"11950\"\u003e5\/8 in\u003c\/strong\u003e. This is very important information, especially when replacing an old heat pump.\u003c\/p\u003e\n\u003cp data-start=\"12047\" data-end=\"12401\"\u003eNever assume existing lines are compatible. At AirGreen, we always check the diameter, condition of the lines, old refrigerant, length, routing, insulation, and accessibility. In many cases, replacing the lines is the best decision to protect the performance and durability of the new system.\u003c\/p\u003e\n\u003ch3 data-start=\"12403\" data-end=\"12446\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"12407\" data-end=\"12446\"\u003e208V \/ 230V Power Supply\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"12448\" data-end=\"12663\"\u003eThe technical sheet specifies a power supply of \u003cstrong data-start=\"12492\" data-end=\"12522\"\u003e208V \/ 230V, 60Hz, single phase\u003c\/strong\u003e, with a \u003cstrong data-start=\"12532\" data-end=\"12547\"\u003eMCA of 22 A\u003c\/strong\u003e and a \u003cstrong data-start=\"12554\" data-end=\"12569\"\u003eMOP of 25 A\u003c\/strong\u003e. This means an appropriate electrical circuit with proper protection must be planned.\u003c\/p\u003e\n\u003cp data-start=\"12665\" data-end=\"12927\"\u003eIn older homes, the electrical panel may already be fully loaded. Before confirming installation, it is necessary to check the available space, wire gauge, circuit breaker, distance to the outdoor unit, and connection compliance.\u003c\/p\u003e\n\u003ch2 data-start=\"12929\" data-end=\"12978\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"12932\" data-end=\"12978\"\u003e7. Energy Performance and Consumption\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"12980\" data-end=\"13197\"\u003eThe \u003cstrong data-start=\"12983\" data-end=\"12996\"\u003eZE-24CB25\u003c\/strong\u003e features a \u003cstrong data-start=\"13008\" data-end=\"13025\"\u003eSEER2 of 22.5\u003c\/strong\u003e, a \u003cstrong data-start=\"13030\" data-end=\"13046\"\u003eHSPF2 of 9.5\u003c\/strong\u003e, an \u003cstrong data-start=\"13051\" data-end=\"13068\"\u003eEER2 of 12.25\u003c\/strong\u003e, and a \u003cstrong data-start=\"13075\" data-end=\"13103\"\u003eCOP of 3.35 W\/W at 8.3 °C\u003c\/strong\u003e. These figures indicate a high-performance heat pump for a large-capacity wall unit.\u003c\/p\u003e\n\u003cp data-start=\"13199\" data-end=\"13601\"\u003eThe \u003cstrong data-start=\"13202\" data-end=\"13211\"\u003eSEER2\u003c\/strong\u003e represents seasonal cooling efficiency. The higher it is, the more efficient the unit is during the cooling season. The \u003cstrong data-start=\"13355\" data-end=\"13364\"\u003eHSPF2\u003c\/strong\u003e relates to heating efficiency over a season. The \u003cstrong data-start=\"13419\" data-end=\"13427\"\u003eEER2\u003c\/strong\u003e provides an efficiency indication under specific cooling conditions. The \u003cstrong data-start=\"13512\" data-end=\"13519\"\u003eCOP\u003c\/strong\u003e indicates the ratio between thermal energy produced and electricity consumed.\u003c\/p\u003e\n\u003cp data-start=\"13603\" data-end=\"13965\"\u003eFor a customer, the goal is not to memorize every indicator. The important thing is to understand that \u003cstrong data-start=\"13706\" data-end=\"13813\"\u003eenergy performance depends as much on the machine as on the installation and actual use\u003c\/strong\u003e. A well-placed, well-calibrated, and well-maintained heat pump will always deliver better results than a high-performance machine installed without analysis.  \u003c\/p\u003e\n\u003ch2 data-start=\"13967\" data-end=\"14030\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"13970\" data-end=\"14030\"\u003e8. Maintenance and durability of the Zephyr CB25 heat pump  \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"14032\" data-end=\"14194\"\u003eA wall-mounted heat pump like the \u003cstrong data-start=\"14064\" data-end=\"14089\"\u003eZephyr CB25 ZE-24CB25\u003c\/strong\u003e should be maintained regularly to preserve its efficiency, noise level, and air quality.  \u003c\/p\u003e\n\u003cp data-start=\"14196\" data-end=\"14225\"\u003eWe especially recommend:  \u003c\/p\u003e\n\u003cp data-start=\"14227\" data-end=\"14676\"\u003e• \u003cstrong data-start=\"14229\" data-end=\"14267\"\u003eClean the filters regularly\u003c\/strong\u003e  \u003cbr data-start=\"14267\" data-end=\"14270\"\u003e• Ensure the condensation drain remains clear  \u003cbr data-start=\"14322\" data-end=\"14325\"\u003e• Keep the outdoor unit free of leaves, dust, snow, and ice  \u003cbr data-start=\"14397\" data-end=\"14400\"\u003e• Monitor for any unusual noises  \u003cbr data-start=\"14434\" data-end=\"14437\"\u003e• Have the unit inspected if performance decreases  \u003cbr data-start=\"14491\" data-end=\"14494\"\u003e• Clean the indoor heat exchanger when necessary  \u003cbr data-start=\"14545\" data-end=\"14548\"\u003e• Check clearances around the outdoor unit before winter  \u003cbr data-start=\"14617\" data-end=\"14620\"\u003e• Schedule professional maintenance based on usage  \u003c\/p\u003e\n\u003cp data-start=\"14678\" data-end=\"14961\"\u003eThe brochure mentions an \u003cstrong data-start=\"14716\" data-end=\"14741\"\u003eautomatic cleaning\u003c\/strong\u003e function, an \u003cstrong data-start=\"14746\" data-end=\"14771\"\u003eautomatic defrost\u003c\/strong\u003e, a \u003cstrong data-start=\"14776\" data-end=\"14821\"\u003eheated chassis for the outdoor base\u003c\/strong\u003e, and \u003cstrong data-start=\"14828\" data-end=\"14856\"\u003ecompressor heating\u003c\/strong\u003e. These features help the unit perform better, but they do not replace proper maintenance.  \u003c\/p\u003e\n\u003ch2 data-start=\"14963\" data-end=\"15036\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"14966\" data-end=\"15036\"\u003e9. Mistakes to avoid before buying a 24,000 BTU heat pump  \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"15038\" data-end=\"15177\"\u003eThe most common mistakes don’t always come from the choice of brand. They often come from a poor project assessment.  \u003c\/p\u003e\n\u003cp data-start=\"15179\" data-end=\"15207\"\u003eHere are the mistakes to avoid:  \u003c\/p\u003e\n\u003cp data-start=\"15209\" data-end=\"15835\"\u003e• Choosing a \u003cstrong data-start=\"15223\" data-end=\"15237\"\u003e24,000 BTU\u003c\/strong\u003e simply because it seems more powerful  \u003cbr data-start=\"15284\" data-end=\"15287\"\u003e• Neglecting the analysis of area and insulation\u003cbr data-start=\"15342\" data-end=\"15345\"\u003e• Forgetting to check the electrical panel\u003cbr data-start=\"15388\" data-end=\"15391\"\u003e• Assuming the old piping is compatible\u003cbr data-start=\"15442\" data-end=\"15445\"\u003e• Installing the indoor unit in a convenient but ineffective location for air distribution\u003cbr data-start=\"15538\" data-end=\"15541\"\u003e• Installing the outdoor unit too close to a wall, fence, or neighbor\u003cbr data-start=\"15620\" data-end=\"15623\"\u003e• Underestimating the importance of drainage\u003cbr data-start=\"15662\" data-end=\"15665\"\u003e• Ignoring future access for maintenance\u003cbr data-start=\"15705\" data-end=\"15708\"\u003e• Comparing only price without comparing installation quality\u003cbr data-start=\"15779\" data-end=\"15782\"\u003e• Not validating low-temperature performance\u003c\/p\u003e\n\u003cp data-start=\"15837\" data-end=\"16007\"\u003eAt AirGreen, we prefer to clarify these elements before work begins. This helps avoid unpleasant surprises, costly adjustments, and unrealistic expectations.\u003c\/p\u003e\n\u003ch2 data-start=\"16009\" data-end=\"16073\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"16012\" data-end=\"16073\"\u003e10. Why choose AirGreen to install the ZE-24CB25\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"16075\" data-end=\"16370\"\u003eAirGreen is a company specialized in \u003cstrong data-start=\"16118\" data-end=\"16126\"\u003eHVAC\u003c\/strong\u003e, active in the installation, maintenance, and repair of wall-mounted, central, and multi-zone heat pumps. We regularly operate in \u003cstrong data-start=\"16268\" data-end=\"16369\"\u003eMontreal, Laval, Longueuil, on the South Shore, the North Shore, and the greater metropolitan area\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"16372\" data-end=\"16489\"\u003eBy choosing AirGreen to install a \u003cstrong data-start=\"16415\" data-end=\"16446\"\u003eZephyr CB25 R454B ZE-24CB25\u003c\/strong\u003e, you benefit from a comprehensive approach:\u003c\/p\u003e\n\u003cp data-start=\"16491\" data-end=\"16942\"\u003e• \u003cstrong data-start=\"16493\" data-end=\"16532\"\u003eClear evaluation before work begins\u003c\/strong\u003e\u003cbr data-start=\"16532\" data-end=\"16535\"\u003e• Verification of proper sizing\u003cbr data-start=\"16572\" data-end=\"16575\"\u003e• Analysis of indoor and outdoor placement\u003cbr data-start=\"16624\" data-end=\"16627\"\u003e• Electrical validation\u003cbr data-start=\"16650\" data-end=\"16653\"\u003e• Required piping inspection\u003cbr data-start=\"16692\" data-end=\"16695\"\u003e• Installation compliant with good HVAC practices\u003cbr data-start=\"16744\" data-end=\"16747\"\u003e• Honest explanation of low-temperature performance\u003cbr data-start=\"16805\" data-end=\"16808\"\u003e• Structured after-sales service\u003cbr data-start=\"16839\" data-end=\"16842\"\u003e• Support for maintenance and use\u003cbr data-start=\"16892\" data-end=\"16895\"\u003e• Local expertise in Quebec buildings\u003c\/p\u003e\n\u003cp data-start=\"16944\" data-end=\"17233\"\u003eThe \u003cstrong data-start=\"16947\" data-end=\"16960\"\u003eZE-24CB25\u003c\/strong\u003e is a powerful, efficient, and well-equipped wall-mounted heat pump. It can be an excellent solution for customers who want to cool and heat a large space with a modern unit using \u003cstrong data-start=\"17167\" data-end=\"17176\"\u003eR454B\u003c\/strong\u003e, capable of operating down to \u003cstrong data-start=\"17209\" data-end=\"17219\"\u003e-30 °C\u003c\/strong\u003e in heating mode.\u003c\/p\u003e\n\u003cp data-start=\"17235\" data-end=\"17482\"\u003eBut as with any HVAC system, the success of the project depends on the installation. The right model, in the right place, with the right piping, the right electrical circuit, and proper clearances will deliver a much more reliable and comfortable result.\u003c\/p\u003e\n\u003cp data-start=\"17484\" data-end=\"17810\"\u003eTo get a clear quote, compare this model with other wall-mounted heat pumps or plan an installation in \u003cstrong data-start=\"17606\" data-end=\"17669\"\u003eMontreal, Laval, Longueuil, on the South Shore or the North Shore\u003c\/strong\u003e, contact AirGreen. Our team will help you choose a solution suited to your building, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665926340900,"sku":"ZE-24CB25I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRCB25R454BGRANDMONTREAL_b20008f6-9f25-4b99-be48-5c15c32955f7.png?v=1783695902"},{"product_id":"thermopompe-murale-zephyr-ub32-r454b-9000-btu-montreal-laval-rive-sud","title":"ZEPHYR UB32 R454B Wall Heat Pump | 9000 BTU | Montreal, Laval, South Shore","description":"\u003ch1 data-start=\"0\" data-end=\"118\" class=\"PDq2pG_selectionAnchorContainer\"\u003e\n\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2\" data-end=\"118\"\u003eZephyr UB32 R454B Wall-Mounted Heat Pump ZE-09UB32: an ultra-efficient 9,000 BTU solution for Quebec comfort\u003c\/strong\u003e\u003c\/span\u003e\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp data-start=\"120\" data-end=\"637\"\u003eThe \u003cstrong data-start=\"123\" data-end=\"173\"\u003eZephyr UB32 R454B Wall-Mounted Heat Pump ZE-09UB32\u003c\/strong\u003e is aimed at owners looking for a compact, high-performance HVAC solution designed for Quebec’s climate realities. With its nominal capacity of \u003cstrong data-start=\"336\" data-end=\"366\"\u003e9,000 BTU in cooling\u003c\/strong\u003e, efficiency reaching \u003cstrong data-start=\"400\" data-end=\"412\"\u003e32 SEER2\u003c\/strong\u003e, heating down to \u003cstrong data-start=\"436\" data-end=\"446\"\u003e-30 °C\u003c\/strong\u003e, and operation with refrigerant \u003cstrong data-start=\"484\" data-end=\"493\"\u003eR454B\u003c\/strong\u003e, this model is particularly suitable for a bedroom, office, condo, small open area, or a room difficult to balance.\u003c\/p\u003e\n\u003cp data-start=\"639\" data-end=\"1094\"\u003eAt AirGreen, we recommend this type of unit when the customer wants an efficient, quiet wall-mounted heat pump well suited to a specific space. The \u003cstrong data-start=\"805\" data-end=\"818\"\u003eZE-09UB32\u003c\/strong\u003e model is not an oversized machine designed for large volumes: it is rather a high-efficiency wall-mounted heat pump capable of providing stable comfort while limiting energy consumption when properly selected, installed, and configured.\u003c\/p\u003e\n\u003cp data-start=\"1096\" data-end=\"1635\"\u003eThe Zephyr UB32 brochure highlights several important features: \u003cstrong data-start=\"1167\" data-end=\"1187\"\u003eup to 32 SEER2\u003c\/strong\u003e, \u003cstrong data-start=\"1189\" data-end=\"1216\"\u003e12 HSPF2 depending on the series\u003c\/strong\u003e, \u003cstrong data-start=\"1218\" data-end=\"1246\"\u003eheating down to -30 °C\u003c\/strong\u003e, \u003cstrong data-start=\"1248\" data-end=\"1280\"\u003ecooling down to -15 °C\u003c\/strong\u003e, variable frequency technology, silent mode, night mode, iFeel mode, automatic defrost, automatic cleaning, automatic oscillation, and operation with \u003cstrong data-start=\"1444\" data-end=\"1453\"\u003eR454B\u003c\/strong\u003e. These features make it a modern solution for residential installations in Montreal, Laval, Longueuil, the South Shore, and the North Shore.\u003c\/p\u003e\n\u003ch2 data-start=\"1637\" data-end=\"1703\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1640\" data-end=\"1703\"\u003eKey technical features of the ZE-09UB32 model\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"1705\" data-end=\"1806\"\u003eFor the model \u003cstrong data-start=\"1720\" data-end=\"1745\"\u003eZephyr UB32 ZE-09UB32\u003c\/strong\u003e, the main brochure data are as follows:\u003c\/p\u003e\n\u003cp data-start=\"1808\" data-end=\"2888\"\u003e• \u003cstrong data-start=\"1810\" data-end=\"1829\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"1829\" data-end=\"1832\"\u003e• \u003cstrong data-start=\"1834\" data-end=\"1850\"\u003eSeries: UB32\u003c\/strong\u003e\u003cbr data-start=\"1850\" data-end=\"1853\"\u003e• \u003cstrong data-start=\"1855\" data-end=\"1884\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"1884\" data-end=\"1887\"\u003e• \u003cstrong data-start=\"1889\" data-end=\"1911\"\u003eModel: ZE-09UB32\u003c\/strong\u003e\u003cbr data-start=\"1911\" data-end=\"1914\"\u003e• \u003cstrong data-start=\"1916\" data-end=\"1969\"\u003eCooling capacity at 35 °C: 9,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"1969\" data-end=\"1972\"\u003e• \u003cstrong data-start=\"1974\" data-end=\"2023\"\u003eHeating capacity at 8.3 °C: 12,200 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"2023\" data-end=\"2026\"\u003e• \u003cstrong data-start=\"2028\" data-end=\"2042\"\u003eSEER2: 32\u003c\/strong\u003e\u003cbr data-start=\"2042\" data-end=\"2045\"\u003e• \u003cstrong data-start=\"2047\" data-end=\"2066\"\u003eHSPF2 IV: 11.8\u003c\/strong\u003e\u003cbr data-start=\"2066\" data-end=\"2069\"\u003e• \u003cstrong data-start=\"2071\" data-end=\"2093\"\u003eEER2: 18.35 BTU\/W\u003c\/strong\u003e\u003cbr data-start=\"2093\" data-end=\"2096\"\u003e• \u003cstrong data-start=\"2098\" data-end=\"2130\"\u003eHeating COP at 8.3 °C: 4.6\u003c\/strong\u003e\u003cbr data-start=\"2130\" data-end=\"2133\"\u003e• \u003cstrong data-start=\"2135\" data-end=\"2158\"\u003eCOP at -15 °C: 2.25\u003c\/strong\u003e\u003cbr data-start=\"2158\" data-end=\"2161\"\u003e• \u003cstrong data-start=\"2163\" data-end=\"2189\"\u003eEnergy Star V6.1: yes\u003c\/strong\u003e\u003cbr data-start=\"2189\" data-end=\"2192\"\u003e• \u003cstrong data-start=\"2194\" data-end=\"2217\"\u003eRefrigerant: R454B\u003c\/strong\u003e\u003cbr data-start=\"2217\" data-end=\"2220\"\u003e• \u003cstrong data-start=\"2222\" data-end=\"2258\"\u003eRefrigerant charge: 52.91 oz\u003c\/strong\u003e\u003cbr data-start=\"2258\" data-end=\"2261\"\u003e• \u003cstrong data-start=\"2263\" data-end=\"2294\"\u003eAirflow: 241 to 365 CFM\u003c\/strong\u003e\u003cbr data-start=\"2294\" data-end=\"2297\"\u003e• \u003cstrong data-start=\"2299\" data-end=\"2364\"\u003eIndoor sound pressure: 47 \/ 41 \/ 38 \/ 33 \/ 29 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"2364\" data-end=\"2367\"\u003e• \u003cstrong data-start=\"2369\" data-end=\"2414\"\u003eOutdoor sound pressure: 54 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"2414\" data-end=\"2417\"\u003e• \u003cstrong data-start=\"2419\" data-end=\"2460\"\u003eVoltage: 208 \/ 230 V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"2460\" data-end=\"2463\"\u003e• \u003cstrong data-start=\"2465\" data-end=\"2479\"\u003eMCA: 14 A\u003c\/strong\u003e\u003cbr data-start=\"2479\" data-end=\"2482\"\u003e• \u003cstrong data-start=\"2484\" data-end=\"2498\"\u003eMOP: 20 A\u003c\/strong\u003e\u003cbr data-start=\"2498\" data-end=\"2501\"\u003e• \u003cstrong data-start=\"2503\" data-end=\"2567\"\u003eRequired communication wire: 4\/14 copper multistrand 600 V\u003c\/strong\u003e\u003cbr data-start=\"2567\" data-end=\"2570\"\u003e• \u003cstrong data-start=\"2572\" data-end=\"2603\"\u003eLiquid piping: 1\/4 in\u003c\/strong\u003e\u003cbr data-start=\"2603\" data-end=\"2606\"\u003e• \u003cstrong data-start=\"2608\" data-end=\"2635\"\u003eGas piping: 1\/2 in\u003c\/strong\u003e\u003cbr data-start=\"2635\" data-end=\"2638\"\u003e• \u003cstrong data-start=\"2640\" data-end=\"2692\"\u003eMinimum-maximum piping length: 10 to 98.4 feet\u003c\/strong\u003e\u003cbr data-start=\"2692\" data-end=\"2695\"\u003e• \u003cstrong data-start=\"2697\" data-end=\"2734\"\u003eMaximum elevation difference: 65 feet\u003c\/strong\u003e\u003cbr data-start=\"2734\" data-end=\"2737\"\u003e• \u003cstrong data-start=\"2739\" data-end=\"2775\"\u003ePrecharge length: 25 feet\u003c\/strong\u003e\u003cbr data-start=\"2775\" data-end=\"2778\"\u003e• \u003cstrong data-start=\"2780\" data-end=\"2823\"\u003eZephyr basic warranty: 10 years parts\u003c\/strong\u003e\u003cbr data-start=\"2823\" data-end=\"2826\"\u003e• \u003cstrong data-start=\"2828\" data-end=\"2888\"\u003eLabor warranty: available according to the distributor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"2890\" data-end=\"3060\"\u003eThe dimensions shown in the brochure are given in \u003cstrong data-start=\"2955\" data-end=\"2968\"\u003eL × H × D\u003c\/strong\u003e format. To facilitate reading during installation, they can be presented in \u003cstrong data-start=\"3045\" data-end=\"3058\"\u003eL × D × H\u003c\/strong\u003e format:\u003c\/p\u003e\n\u003cp data-start=\"3062\" data-end=\"3162\"\u003e• \u003cstrong data-start=\"3064\" data-end=\"3110\"\u003eIndoor unit: 42.06 × 9.06 × 12.63 in\u003c\/strong\u003e\u003cbr data-start=\"3110\" data-end=\"3113\"\u003e• \u003cstrong data-start=\"3115\" data-end=\"3162\"\u003eOutdoor unit: 33.88 × 12.19 × 25.50 in\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3164\" data-end=\"3524\"\u003eThis information is essential before confirming an installation. A 9,000 BTU heat pump may seem simple to install, but it is still necessary to verify \u003cstrong data-start=\"3323\" data-end=\"3353\"\u003ethe available wall space\u003c\/strong\u003e, \u003cstrong data-start=\"3355\" data-end=\"3386\"\u003ethe piping passage\u003c\/strong\u003e, \u003cstrong data-start=\"3388\" data-end=\"3417\"\u003ethe electrical supply\u003c\/strong\u003e, \u003cstrong data-start=\"3419\" data-end=\"3446\"\u003ethe outdoor clearance\u003c\/strong\u003e, \u003cstrong data-start=\"3448\" data-end=\"3463\"\u003ethe drainage\u003c\/strong\u003e, and \u003cstrong data-start=\"3467\" data-end=\"3523\"\u003ecompatibility with the client’s actual expectations\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-start=\"3526\" data-end=\"3585\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"3529\" data-end=\"3585\"\u003eVery high energy efficiency with 32 SEER2\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"3587\" data-end=\"3857\"\u003eThe most impressive point of the \u003cstrong data-start=\"3625\" data-end=\"3645\"\u003eZephyr ZE-09UB32\u003c\/strong\u003e is its cooling performance. With a \u003cstrong data-start=\"3690\" data-end=\"3705\"\u003eSEER2 of 32\u003c\/strong\u003e, this model positions itself as a very high-performance wall-mounted heat pump for customers who want to reduce their electricity consumption during the summer.\u003c\/p\u003e\n\u003cp data-start=\"3859\" data-end=\"4289\"\u003eThe SEER2 measures seasonal cooling efficiency. The higher the value, the more effectively the device can produce cooling over an entire season. In the context of Greater Montreal, where heat waves can become intense, a high-efficiency machine can make a real difference, especially when used daily in a bedroom, office, or living area.\u003c\/p\u003e\n\u003cp data-start=\"4291\" data-end=\"4614\"\u003eAnother advantage is the \u003cstrong data-start=\"4315\" data-end=\"4338\"\u003eEER2 of 18.35 BTU\/W\u003c\/strong\u003e, which indicates very good cooling efficiency under specific conditions. For a customer, this means the machine is not only efficient on paper: it is designed to maintain a good level of comfort with controlled electricity consumption.\u003c\/p\u003e\n\u003cp data-start=\"4616\" data-end=\"4925\"\u003eAt AirGreen, we always explain that energy efficiency also depends on installation. A very efficient heat pump can lose some of its advantage if it is poorly positioned, if the piping is poorly adapted, if the drain is misconfigured, or if the outdoor unit lacks clearance.\u003c\/p\u003e\n\u003ch2 data-start=\"4927\" data-end=\"4992\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4930\" data-end=\"4992\"\u003eHeating down to -30 °C: a real advantage for Quebec\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4994\" data-end=\"5343\"\u003eThe Zephyr brochure presents the UB32 series as a heat pump capable of providing heating down to \u003cstrong data-start=\"5098\" data-end=\"5108\"\u003e-30 °C\u003c\/strong\u003e. This is an important feature for Quebec homeowners who want to use their heat pump not only as an air conditioner but also as a primary or supplementary heating source for much of the winter.\u003c\/p\u003e\n\u003cp data-start=\"5345\" data-end=\"5445\"\u003eFor the model \u003cstrong data-start=\"5360\" data-end=\"5373\"\u003eZE-09UB32\u003c\/strong\u003e, the indicated heating performance is particularly useful:\u003c\/p\u003e\n\u003cp data-start=\"5447\" data-end=\"5594\"\u003e• \u003cstrong data-start=\"5449\" data-end=\"5474\"\u003e12,200 BTU\/h at 8.3 °C\u003c\/strong\u003e\u003cbr data-start=\"5474\" data-end=\"5477\"\u003e• \u003cstrong data-start=\"5479\" data-end=\"5505\"\u003e13,000 BTU\/h at -8.3 °C\u003c\/strong\u003e\u003cbr data-start=\"5505\" data-end=\"5508\"\u003e• \u003cstrong data-start=\"5510\" data-end=\"5535\"\u003e12,200 BTU\/h at -15 °C\u003c\/strong\u003e\u003cbr data-start=\"5535\" data-end=\"5538\"\u003e• \u003cstrong data-start=\"5540\" data-end=\"5565\"\u003e11,300 BTU\/h at -20 °C\u003c\/strong\u003e\u003cbr data-start=\"5565\" data-end=\"5568\"\u003e• \u003cstrong data-start=\"5570\" data-end=\"5594\"\u003e9,000 BTU\/h at -25 °C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5596\" data-end=\"5954\"\u003eThese figures show that the machine retains a significant capacity at low temperatures. However, it is important to understand what this means. \u003cstrong data-start=\"5746\" data-end=\"5879\"\u003eA heat pump that operates down to -30 °C does not always produce the same power at -30 °C as it does at a milder temperature.\u003c\/strong\u003e Capacity generally decreases as the outside temperature drops.\u003c\/p\u003e\n\u003cp data-start=\"5956\" data-end=\"6374\"\u003eIn a well-insulated house, a model like the \u003cstrong data-start=\"6004\" data-end=\"6017\"\u003eZE-09UB32\u003c\/strong\u003e can be very effective for heating a specific room or area. In an older, poorly insulated, or very windy house, supplementary heating may still be necessary during extreme cold periods. Our role is to assess the building, area, insulation, windows, and actual use of the room before recommending this model.\u003c\/p\u003e\n\u003ch2 data-start=\"6376\" data-end=\"6451\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6379\" data-end=\"6451\"\u003eR454B: a modern refrigerant for new HVAC installations\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"6453\" data-end=\"6837\"\u003eThe \u003cstrong data-start=\"6456\" data-end=\"6481\"\u003eZephyr UB32 ZE-09UB32\u003c\/strong\u003e uses the refrigerant \u003cstrong data-start=\"6505\" data-end=\"6514\"\u003eR454B\u003c\/strong\u003e. This gas is part of the new refrigerants used in recent generations of HVAC equipment. For the customer, the refrigerant name may seem technical, but it is important because it influences the design of the unit, installation practices, and the evolution of available equipment on the market.\u003c\/p\u003e\n\u003cp data-start=\"6839\" data-end=\"7172\"\u003eWith a charge of \u003cstrong data-start=\"6858\" data-end=\"6870\"\u003e52.91 oz\u003c\/strong\u003e, this heat pump must be installed according to the manufacturer's guidelines. Steps such as leak testing, vacuuming, checking connections, respecting pipe length, and commissioning are essential. \u003cstrong data-start=\"7110\" data-end=\"7172\"\u003eA modern heat pump requires a rigorous installation.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"7174\" data-end=\"7511\"\u003eAt AirGreen, we pay special attention to installations using new refrigerants. The quality of flare connections, line cleanliness, electrical compliance, and final inspection are not minor details: they are essential conditions to preserve the performance and durability of the unit.\u003c\/p\u003e\n\u003ch2 data-start=\"7513\" data-end=\"7596\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"7516\" data-end=\"7596\"\u003eIndoor comfort: 4D mode, automatic oscillation, and Inverter technology\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"7598\" data-end=\"7876\"\u003eThe brochure highlights the \u003cstrong data-start=\"7626\" data-end=\"7637\"\u003e4D mode\u003c\/strong\u003e and \u003cstrong data-start=\"7643\" data-end=\"7670\"\u003eautomatic oscillation\u003c\/strong\u003e, two important features to improve air distribution in the room. The goal is simple: to avoid cold or hot spots and help the heat pump maintain a more even temperature.\u003c\/p\u003e\n\u003cp data-start=\"7878\" data-end=\"8296\"\u003eIn a bedroom, for example, a poor air jet can quickly become uncomfortable if the unit blows directly toward the bed. In an office, poorly directed airflow can be disturbing for several hours. In a living room, poor distribution can leave part of the room too hot or too cold. The \u003cstrong data-start=\"8199\" data-end=\"8210\"\u003e4D mode\u003c\/strong\u003e helps better direct the air, but the location of the indoor unit remains essential.\u003c\/p\u003e\n\u003cp data-start=\"8298\" data-end=\"8643\"\u003eVariable frequency technology, often called \u003cstrong data-start=\"8351\" data-end=\"8363\"\u003eInverter\u003c\/strong\u003e, allows the device to adjust its power in real time. Instead of simply turning on and off, the heat pump modulates its effort according to needs. This reduces temperature fluctuations, improves comfort, and limits energy consumption.\u003c\/p\u003e\n\u003cp data-start=\"8645\" data-end=\"8812\"\u003eThis is very important: \u003cstrong data-start=\"8677\" data-end=\"8812\"\u003eperformance comes not only from BTU power but from the machine’s ability to maintain a stable temperature.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch2 data-start=\"8814\" data-end=\"8871\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"8817\" data-end=\"8871\"\u003eConvenient features for everyday use\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"8873\" data-end=\"8972\"\u003eThe Zephyr UB32 series includes several features designed to make daily use easier:\u003c\/p\u003e\n\u003cp data-start=\"8974\" data-end=\"9571\"\u003e• \u003cstrong data-start=\"8976\" data-end=\"8989\"\u003eNight mode\u003c\/strong\u003e\u003cbr data-start=\"8989\" data-end=\"8992\"\u003e• \u003cstrong data-start=\"8994\" data-end=\"9010\"\u003eSilent mode\u003c\/strong\u003e\u003cbr data-start=\"9010\" data-end=\"9013\"\u003e• \u003cstrong data-start=\"9015\" data-end=\"9029\"\u003eiFeel mode\u003c\/strong\u003e\u003cbr data-start=\"9029\" data-end=\"9032\"\u003e• \u003cstrong data-start=\"9034\" data-end=\"9054\"\u003eQuick start\u003c\/strong\u003e\u003cbr data-start=\"9054\" data-end=\"9057\"\u003e• \u003cstrong data-start=\"9059\" data-end=\"9077\"\u003e24-hour timer\u003c\/strong\u003e\u003cbr data-start=\"9077\" data-end=\"9080\"\u003e• \u003cstrong data-start=\"9082\" data-end=\"9100\"\u003eTurbo function\u003c\/strong\u003e\u003cbr data-start=\"9100\" data-end=\"9103\"\u003e• \u003cstrong data-start=\"9105\" data-end=\"9134\"\u003eLED wireless remote control\u003c\/strong\u003e\u003cbr data-start=\"9134\" data-end=\"9137\"\u003e• \u003cstrong data-start=\"9139\" data-end=\"9158\"\u003eLED dimmer\u003c\/strong\u003e\u003cbr data-start=\"9158\" data-end=\"9161\"\u003e• \u003cstrong data-start=\"9163\" data-end=\"9203\"\u003e5 indoor fan speeds\u003c\/strong\u003e\u003cbr data-start=\"9203\" data-end=\"9206\"\u003e• \u003cstrong data-start=\"9208\" data-end=\"9244\"\u003eDiffuser position memory\u003c\/strong\u003e\u003cbr data-start=\"9244\" data-end=\"9247\"\u003e• \u003cstrong data-start=\"9249\" data-end=\"9274\"\u003eAutomatic cleaning\u003c\/strong\u003e\u003cbr data-start=\"9274\" data-end=\"9277\"\u003e• \u003cstrong data-start=\"9279\" data-end=\"9304\"\u003eAutomatic defrost\u003c\/strong\u003e\u003cbr data-start=\"9304\" data-end=\"9307\"\u003e• \u003cstrong data-start=\"9309\" data-end=\"9347\"\u003eAutomatic heating 8 °C \/ 46 °F\u003c\/strong\u003e\u003cbr data-start=\"9347\" data-end=\"9350\"\u003e• \u003cstrong data-start=\"9352\" data-end=\"9374\"\u003eTwo-sided drain\u003c\/strong\u003e\u003cbr data-start=\"9374\" data-end=\"9377\"\u003e• \u003cstrong data-start=\"9379\" data-end=\"9407\"\u003eReversible drain pipe\u003c\/strong\u003e\u003cbr data-start=\"9407\" data-end=\"9410\"\u003e• \u003cstrong data-start=\"9412\" data-end=\"9441\"\u003eFireproof electrical box\u003c\/strong\u003e\u003cbr data-start=\"9441\" data-end=\"9444\"\u003e• \u003cstrong data-start=\"9446\" data-end=\"9488\"\u003eSelf-adaptive voltage technology\u003c\/strong\u003e\u003cbr data-start=\"9488\" data-end=\"9491\"\u003e• \u003cstrong data-start=\"9493\" data-end=\"9521\"\u003eCompressor heating\u003c\/strong\u003e\u003cbr data-start=\"9521\" data-end=\"9524\"\u003e• \u003cstrong data-start=\"9526\" data-end=\"9571\"\u003eHeated chassis for the outdoor base\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"9573\" data-end=\"9977\"\u003eThese features do not replace good installation but clearly improve the user experience. The \u003cstrong data-start=\"9691\" data-end=\"9707\"\u003esilent mode\u003c\/strong\u003e can be useful in a bedroom. The \u003cstrong data-start=\"9745\" data-end=\"9758\"\u003enight mode\u003c\/strong\u003e helps maintain discreet comfort during sleep. The \u003cstrong data-start=\"9823\" data-end=\"9837\"\u003eiFeel mode\u003c\/strong\u003e adjusts comfort based on the temperature sensed around the remote control, which can be very practical in certain rooms.\u003c\/p\u003e\n\u003cp data-start=\"9979\" data-end=\"10388\"\u003eThe \u003cstrong data-start=\"9982\" data-end=\"10007\"\u003eautomatic defrost\u003c\/strong\u003e, \u003cstrong data-start=\"10012\" data-end=\"10040\"\u003ecompressor heating\u003c\/strong\u003e, and \u003cstrong data-start=\"10047\" data-end=\"10078\"\u003eheated outdoor chassis\u003c\/strong\u003e are especially relevant for Quebec’s climate. In winter, the outdoor unit is exposed to frost, snow, and moisture. These features help the device better handle harsh conditions, provided the outdoor unit is installed with proper clearances and on a suitable base.\u003c\/p\u003e\n\u003ch2 data-start=\"10390\" data-end=\"10444\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10393\" data-end=\"10444\"\u003eA 9,000 BTU heat pump: for which spaces?\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"10446\" data-end=\"10572\"\u003eA 9,000 BTU wall-mounted heat pump generally suits more targeted spaces. It can be a good solution for:\u003c\/p\u003e\n\u003cp data-start=\"10574\" data-end=\"10847\"\u003e• a master bedroom;\u003cbr data-start=\"10599\" data-end=\"10602\"\u003e• a home office;\u003cbr data-start=\"10625\" data-end=\"10628\"\u003e• a small open area;\u003cbr data-start=\"10654\" data-end=\"10657\"\u003e• a well-insulated condo;\u003cbr data-start=\"10679\" data-end=\"10682\"\u003e• a room above a garage;\u003cbr data-start=\"10716\" data-end=\"10719\"\u003e• a home extension;\u003cbr data-start=\"10745\" data-end=\"10748\"\u003e• a partially open basement;\u003cbr data-start=\"10783\" data-end=\"10786\"\u003e• a space that remains too hot in summer or too cold in winter.\u003c\/p\u003e\n\u003cp data-start=\"10849\" data-end=\"11172\"\u003eHowever, choosing a 9,000 BTU unit should never be based solely on the area. You must also consider \u003cstrong data-start=\"10970\" data-end=\"10985\"\u003einsulation\u003c\/strong\u003e, \u003cstrong data-start=\"10987\" data-end=\"11017\"\u003ewindow orientation\u003c\/strong\u003e, \u003cstrong data-start=\"11019\" data-end=\"11044\"\u003eceiling height\u003c\/strong\u003e, \u003cstrong data-start=\"11046\" data-end=\"11072\"\u003esun exposure\u003c\/strong\u003e, \u003cstrong data-start=\"11074\" data-end=\"11098\"\u003eair circulation\u003c\/strong\u003e, \u003cstrong data-start=\"11100\" data-end=\"11123\"\u003eroom usage\u003c\/strong\u003e, and \u003cstrong data-start=\"11127\" data-end=\"11171\"\u003edesired heating level in winter\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"11174\" data-end=\"11590\"\u003eIn a recent condo in Montreal, a 9,000 BTU unit can be sufficient for a well-designed living area. In a house in Laval, it can be ideal for a bedroom or an office. On the South Shore, it can suit a room heavily exposed to the sun if properly sized. On the North Shore, it can be useful to supplement heating in an area farther from the main system.\u003c\/p\u003e\n\u003cp data-start=\"11592\" data-end=\"11914\"\u003e\u003cstrong data-start=\"11592\" data-end=\"11662\"\u003eAn overly powerful device can reduce comfort in air conditioning\u003c\/strong\u003e because it reaches the temperature too quickly without properly dehumidifying. Conversely, an undersized device will run constantly and struggle during extreme days. That’s why evaluation before installation is essential.\u003c\/p\u003e\n\u003ch2 data-start=\"11916\" data-end=\"11980\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11919\" data-end=\"11980\"\u003eElectrical installation: 208\/230 V, MCA 14 A, and MOP 20 A\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"11982\" data-end=\"12204\"\u003eThe \u003cstrong data-start=\"11992\" data-end=\"12005\"\u003eZE-09UB32\u003c\/strong\u003e model operates at \u003cstrong data-start=\"12020\" data-end=\"12049\"\u003e208\/230 V, 60 Hz, single phase\u003c\/strong\u003e. The technical sheet indicates a \u003cstrong data-start=\"12081\" data-end=\"12096\"\u003eMCA of 14 A\u003c\/strong\u003e and a \u003cstrong data-start=\"12103\" data-end=\"12118\"\u003eMOP of 20 A\u003c\/strong\u003e. This data allows validating the required electrical circuit before installation.\u003c\/p\u003e\n\u003cp data-start=\"12206\" data-end=\"12687\"\u003eEven though this model is 9,000 BTU, the importance of electrical verification should not be underestimated. In some older homes in Montreal or Longueuil, the panel may already be fully loaded. In some condos, electrical constraints can also be stricter. Before confirming a project, we always check the available capacity, required breaker, wire gauge, and possible route between the electrical panel and the outdoor unit.\u003c\/p\u003e\n\u003cp data-start=\"12689\" data-end=\"12855\"\u003eThe required communication wire is a \u003cstrong data-start=\"12726\" data-end=\"12761\"\u003e4\/14 copper multi-strand 600 V\u003c\/strong\u003e. This information is important to ensure compliance with the manufacturer's requirements.\u003c\/p\u003e\n\u003ch2 data-start=\"12857\" data-end=\"12922\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"12860\" data-end=\"12922\"\u003e1\/4 - 1\/2 inch piping and maximum length of 98.4 feet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"12924\" data-end=\"13194\"\u003eThe \u003cstrong data-start=\"12927\" data-end=\"12947\"\u003eZephyr ZE-09UB32\u003c\/strong\u003e uses refrigeration piping of \u003cstrong data-start=\"12987\" data-end=\"13013\"\u003e1\/4 inch for the liquid\u003c\/strong\u003e and \u003cstrong data-start=\"13017\" data-end=\"13039\"\u003e1\/2 inch for the gas\u003c\/strong\u003e. The indicated piping length is \u003cstrong data-start=\"13083\" data-end=\"13102\"\u003e10 to 98.4 feet\u003c\/strong\u003e, with a maximum elevation difference of \u003cstrong data-start=\"13139\" data-end=\"13151\"\u003e65 feet\u003c\/strong\u003e and a precharge designed for \u003cstrong data-start=\"13181\" data-end=\"13193\"\u003e25 feet\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"13196\" data-end=\"13497\"\u003eThis data directly influences the installation planning. For replacing an old system, you should never assume the existing lines are compatible. The diameter, condition of the lines, old refrigerant, accessibility, and cleanliness of the path must be checked.\u003c\/p\u003e\n\u003cp data-start=\"13499\" data-end=\"13733\"\u003eAt AirGreen, we prefer to replace the lines when necessary rather than forcing an installation on questionable piping. This can prevent performance, noise, leakage, or warranty issues later on.\u003c\/p\u003e\n\u003ch2 data-start=\"13735\" data-end=\"13801\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"13738\" data-end=\"13801\"\u003eNoise level: a discreet device for living spaces\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"13803\" data-end=\"14024\"\u003eThe datasheet indicates an indoor sound pressure level of \u003cstrong data-start=\"13858\" data-end=\"13890\"\u003e47 \/ 41 \/ 38 \/ 33 \/ 29 dB(A)\u003c\/strong\u003e depending on fan speed, including silent mode. For a bedroom or office, this noise level is a significant advantage.\u003c\/p\u003e\n\u003cp data-start=\"14026\" data-end=\"14329\"\u003eThe unit is rated at \u003cstrong data-start=\"14060\" data-end=\"14072\"\u003e54 dB(A)\u003c\/strong\u003e. This level remains reasonable, but the outdoor location must be chosen carefully. In dense areas of Montreal, Laval, or Longueuil, consider neighbors, windows, balconies, fences, and noise reflection between walls.  \u003c\/p\u003e\n\u003cp data-start=\"14331\" data-end=\"14578\"\u003eA poorly placed outdoor unit may seem louder than it actually is. Professional installation must consider performance, maintenance access, drainage, snow, ice, and acoustic comfort.  \u003c\/p\u003e\n\u003ch2 data-start=\"14580\" data-end=\"14643\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"14583\" data-end=\"14643\"\u003eHVAC maintenance: keep performance year after year  \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"14645\" data-end=\"14806\"\u003eA high-performance wall-mounted heat pump like the \u003cstrong data-start=\"14689\" data-end=\"14702\"\u003eZE-09UB32\u003c\/strong\u003e must be well maintained. Automatic cleaning helps but does not replace regular maintenance.  \u003c\/p\u003e\n\u003cp data-start=\"14808\" data-end=\"14837\"\u003eWe especially recommend:  \u003c\/p\u003e\n\u003cp data-start=\"14839\" data-end=\"15185\"\u003e• clean filters regularly;  \u003cbr data-start=\"14876\" data-end=\"14879\"\u003e• check the condition of the indoor unit;  \u003cbr data-start=\"14919\" data-end=\"14922\"\u003e• monitor the condensation drain;  \u003cbr data-start=\"14960\" data-end=\"14963\"\u003e• keep the outdoor unit clear;  \u003cbr data-start=\"14999\" data-end=\"15002\"\u003e• remove leaves, snow, ice, and debris;  \u003cbr data-start=\"15059\" data-end=\"15062\"\u003e• have the unit inspected if unusual noise occurs;  \u003cbr data-start=\"15118\" data-end=\"15121\"\u003e• request professional cleaning if performance decreases.  \u003c\/p\u003e\n\u003cp data-start=\"15187\" data-end=\"15335\"\u003eProper maintenance helps preserve \u003cstrong data-start=\"15224\" data-end=\"15252\"\u003eenergy efficiency\u003c\/strong\u003e, \u003cstrong data-start=\"15254\" data-end=\"15274\"\u003enoise level\u003c\/strong\u003e, \u003cstrong data-start=\"15276\" data-end=\"15299\"\u003eair quality\u003c\/strong\u003e, and \u003cstrong data-start=\"15303\" data-end=\"15320\"\u003edurability\u003c\/strong\u003e of the device.  \u003c\/p\u003e\n\u003ch2 data-start=\"15337\" data-end=\"15396\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"15340\" data-end=\"15396\"\u003eMistakes to avoid before buying the Zephyr ZE-09UB32  \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"15398\" data-end=\"15534\"\u003eThe most common mistakes don’t always come from the brand choice. They often come from poor project analysis.  \u003c\/p\u003e\n\u003cp data-start=\"15536\" data-end=\"15564\"\u003eHere are the mistakes to avoid:  \u003c\/p\u003e\n\u003cp data-start=\"15566\" data-end=\"16037\"\u003e• choosing a 9,000 BTU unit solely based on area;  \u003cbr data-start=\"15621\" data-end=\"15624\"\u003e• ignoring sun exposure;  \u003cbr data-start=\"15657\" data-end=\"15660\"\u003e• neglecting insulation;  \u003cbr data-start=\"15683\" data-end=\"15686\"\u003e• placing the indoor unit in the wrong location;  \u003cbr data-start=\"15733\" data-end=\"15736\"\u003e• blowing air directly onto the bed, sofa, or desk;  \u003cbr data-start=\"15792\" data-end=\"15795\"\u003e• assuming old lines are compatible;  \u003cbr data-start=\"15848\" data-end=\"15851\"\u003e• forgetting electrical checks;  \u003cbr data-start=\"15888\" data-end=\"15891\"\u003e• installing the outdoor unit too low for winter;  \u003cbr data-start=\"15944\" data-end=\"15947\"\u003e• neglecting drainage;  \u003cbr data-start=\"15970\" data-end=\"15973\"\u003e• buying based only on SEER2 without validating actual comfort.  \u003c\/p\u003e\n\u003cp data-start=\"16039\" data-end=\"16197\"\u003eAt AirGreen, our approach is to clarify these points before installation. This helps avoid unpleasant surprises and ensures a lasting result.  \u003c\/p\u003e\n\u003ch2 data-start=\"16199\" data-end=\"16271\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"16202\" data-end=\"16271\"\u003eWhy choose AirGreen to install the Zephyr UB32 ZE-09UB32  \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"16273\" data-end=\"16548\"\u003eAirGreen installs, maintains, and replaces HVAC systems in Greater Montreal, including \u003cstrong data-start=\"16366\" data-end=\"16425\"\u003eMontreal, Laval, Longueuil, the South Shore, and the North Shore\u003c\/strong\u003e. Our team understands the constraints of condos, plexes, single-family homes, light commercial buildings, and older buildings.\u003c\/p\u003e\n\u003cp data-start=\"16550\" data-end=\"16600\"\u003eBy choosing AirGreen, customers benefit from:\u003c\/p\u003e\n\u003cp data-start=\"16602\" data-end=\"17033\"\u003e• a clear evaluation before work begins;\u003cbr data-start=\"16646\" data-end=\"16649\"\u003e• sizing adapted to the room;\u003cbr data-start=\"16690\" data-end=\"16693\"\u003e• thorough electrical verification;\u003cbr data-start=\"16734\" data-end=\"16737\"\u003e• a clean and compliant installation;\u003cbr data-start=\"16777\" data-end=\"16780\"\u003e• special attention to drainage;\u003cbr data-start=\"16823\" data-end=\"16826\"\u003e• good positioning of the indoor unit;\u003cbr data-start=\"16874\" data-end=\"16877\"\u003e• an outdoor location designed for winter;\u003cbr data-start=\"16925\" data-end=\"16928\"\u003e• structured after-sales service;\u003cbr data-start=\"16965\" data-end=\"16968\"\u003e• an honest explanation of warranties and available options.\u003c\/p\u003e\n\u003cp data-start=\"17035\" data-end=\"17276\"\u003eA heat pump like the \u003cstrong data-start=\"17060\" data-end=\"17080\"\u003eZephyr ZE-09UB32\u003c\/strong\u003e can deliver excellent performance, but only if installed properly. The right model, in the right place, with the right piping and configuration, makes all the difference.\u003c\/p\u003e\n\u003ch2 data-start=\"17278\" data-end=\"17358\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"17281\" data-end=\"17358\"\u003eA compact, efficient wall-mounted heat pump suited for Quebec winters\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"17360\" data-end=\"17881\"\u003eThe \u003cstrong data-start=\"17363\" data-end=\"17413\"\u003eZephyr UB32 R454B Wall-Mounted Heat Pump ZE-09UB32\u003c\/strong\u003e is a very interesting solution for customers who want a compact, efficient, quiet machine capable of heating down to \u003cstrong data-start=\"17569\" data-end=\"17579\"\u003e-30 °C\u003c\/strong\u003e. With its \u003cstrong data-start=\"17590\" data-end=\"17605\"\u003eSEER2 of 32\u003c\/strong\u003e, \u003cstrong data-start=\"17611\" data-end=\"17628\"\u003eHSPF2 of 11.8\u003c\/strong\u003e, refrigerant \u003cstrong data-start=\"17646\" data-end=\"17655\"\u003eR454B\u003c\/strong\u003e, airflow of \u003cstrong data-start=\"17676\" data-end=\"17693\"\u003e241 to 365 CFM\u003c\/strong\u003e, indoor noise level as low as \u003cstrong data-start=\"17743\" data-end=\"17755\"\u003e29 dB(A)\u003c\/strong\u003e, and a basic warranty of \u003cstrong data-start=\"17782\" data-end=\"17799\"\u003e10 years parts\u003c\/strong\u003e, this model offers an excellent balance of performance, comfort, and efficiency.\u003c\/p\u003e\n\u003cp data-start=\"17883\" data-end=\"18150\"\u003eFor a bedroom, office, condo, or specific area of the house, the \u003cstrong data-start=\"17958\" data-end=\"17971\"\u003eZE-09UB32\u003c\/strong\u003e can be a very relevant choice. However, sizing, location, electricity, piping, and clearances must be verified before confirming the installation.\u003c\/p\u003e\n\u003cp data-start=\"18152\" data-end=\"18477\"\u003eTo get a clear quote, compare this model with other wall-mounted heat pumps, or schedule an installation in Montreal, Laval, Longueuil, on the South Shore or the North Shore, contact AirGreen. Our team will help you choose the right HVAC solution based on your building, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665926373668,"sku":"ZE-09UB32I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRUB32R454BGRANDMONTREAL.png?v=1783695896"},{"product_id":"thermopompe-murale-zephyr-ub32-r454b-12000-btu-montreal-laval-rive-sud","title":"ZEPHYR UB32 R454B Wall Heat Pump | 12000 BTU | Montreal, Laval, South Shore","description":"\u003ch2 data-start=\"763\" data-end=\"832\"\u003eA 12,000 BTU wall-mounted heat pump designed for Quebec comfort\u003c\/h2\u003e\n\u003cp data-start=\"834\" data-end=\"1304\"\u003eThe \u003cstrong data-start=\"837\" data-end=\"888\"\u003eZephyr UB32 R454B 12,000 BTU wall-mounted heat pump\u003c\/strong\u003e, model \u003cstrong data-start=\"897\" data-end=\"910\"\u003eZE-12UB32\u003c\/strong\u003e, is aimed at owners looking for a modern, efficient HVAC solution well suited to Quebec's climate realities. With its nominal capacity of \u003cstrong data-start=\"1071\" data-end=\"1102\"\u003e12,000 BTU for cooling\u003c\/strong\u003e, it is particularly suitable for living rooms, condos, offices, master bedrooms, small businesses, or residential spaces where stable comfort is desired both in summer and winter.\u003c\/p\u003e\n\u003cp data-start=\"1306\" data-end=\"1825\"\u003eAt AirGreen, we recommend this type of device when a customer wants a high-performance, quiet, compact wall-mounted heat pump capable of operating efficiently for much of the year. The \u003cstrong data-start=\"1518\" data-end=\"1531\"\u003eZE-12UB32\u003c\/strong\u003e stands out for its very good energy efficiency level, its operation with \u003cstrong data-start=\"1617\" data-end=\"1638\"\u003eR454B refrigerant\u003c\/strong\u003e, its heating range down to \u003cstrong data-start=\"1670\" data-end=\"1680\"\u003e-30 °C\u003c\/strong\u003e, as well as comfort features like \u003cstrong data-start=\"1726\" data-end=\"1739\"\u003enight mode\u003c\/strong\u003e, \u003cstrong data-start=\"1744\" data-end=\"1760\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"1765\" data-end=\"1779\"\u003eiFeel mode\u003c\/strong\u003e, automatic oscillation, and \u003cstrong data-start=\"1813\" data-end=\"1824\"\u003e4D mode\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1827\" data-end=\"2203\"\u003eThis model is not just a 12,000 BTU wall-mounted heat pump. It is a device that requires a thorough analysis before installation: actual area, insulation, ceiling height, window orientation, distance between the indoor and outdoor units, electrical supply, drainage, location of the wall unit, and clearances around the outdoor unit.\u003c\/p\u003e\n\u003cp data-start=\"2205\" data-end=\"2766\"\u003eIn Montreal, Laval, Longueuil, on the South Shore and the North Shore, we often see projects where a 12,000 BTU heat pump can be excellent, but only if it is well placed and properly sized. A unit that performs well on paper can deliver average results if it blows in the wrong direction, is installed in a room that is too closed off, or if the outdoor unit lacks clearance. Conversely, a \u003cstrong data-start=\"2634\" data-end=\"2662\"\u003ewell-installed ZE-12UB32\u003c\/strong\u003e can offer remarkable comfort, reduced consumption, and better temperature stability.\u003c\/p\u003e\n\u003chr data-start=\"2768\" data-end=\"2771\"\u003e\n\u003ch2 data-start=\"2773\" data-end=\"2839\"\u003eThe important technical specifications of the ZE-12UB32 model\u003c\/h2\u003e\n\u003cp data-start=\"2841\" data-end=\"2979\"\u003eFor the \u003cstrong data-start=\"2856\" data-end=\"2869\"\u003eZE-12UB32\u003c\/strong\u003e model, the brochure's technical sheet provides the following information:\u003c\/p\u003e\n\u003cp data-start=\"2981\" data-end=\"4483\"\u003e\u003cstrong data-start=\"2981\" data-end=\"3000\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"3000\" data-end=\"3003\"\u003e\u003cstrong data-start=\"3003\" data-end=\"3019\"\u003eSeries: UB32\u003c\/strong\u003e\u003cbr data-start=\"3019\" data-end=\"3022\"\u003e\u003cstrong data-start=\"3022\" data-end=\"3044\"\u003eModel: ZE-12UB32\u003c\/strong\u003e\u003cbr data-start=\"3044\" data-end=\"3047\"\u003e\u003cstrong data-start=\"3047\" data-end=\"3076\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"3076\" data-end=\"3079\"\u003e\u003cstrong data-start=\"3079\" data-end=\"3102\"\u003eRefrigerant: R454B\u003c\/strong\u003e\u003cbr data-start=\"3102\" data-end=\"3105\"\u003e\u003cstrong data-start=\"3105\" data-end=\"3159\"\u003eCooling capacity at 35 °C: 12,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3159\" data-end=\"3162\"\u003e\u003cstrong data-start=\"3162\" data-end=\"3211\"\u003eHeating capacity at 8.3 °C: 12,200 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3211\" data-end=\"3214\"\u003e\u003cstrong data-start=\"3214\" data-end=\"3228\"\u003eSEER2: 30\u003c\/strong\u003e\u003cbr data-start=\"3228\" data-end=\"3231\"\u003e\u003cstrong data-start=\"3231\" data-end=\"3250\"\u003eHSPF2 IV: 11.8\u003c\/strong\u003e\u003cbr data-start=\"3250\" data-end=\"3253\"\u003e\u003cstrong data-start=\"3253\" data-end=\"3275\"\u003eEER2: 15.35 BTU\/W\u003c\/strong\u003e\u003cbr data-start=\"3275\" data-end=\"3278\"\u003e\u003cstrong data-start=\"3278\" data-end=\"3310\"\u003eHeating COP at 8.3 °C: 4.6\u003c\/strong\u003e\u003cbr data-start=\"3310\" data-end=\"3313\"\u003e\u003cstrong data-start=\"3313\" data-end=\"3372\"\u003eNominal heating capacity at -8.3 °C: 13,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3372\" data-end=\"3375\"\u003e\u003cstrong data-start=\"3375\" data-end=\"3433\"\u003eMaximum heating capacity at -15 °C: 12,200 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3433\" data-end=\"3436\"\u003e\u003cstrong data-start=\"3436\" data-end=\"3459\"\u003eCOP at -15 °C: 2.25\u003c\/strong\u003e\u003cbr data-start=\"3459\" data-end=\"3462\"\u003e\u003cstrong data-start=\"3462\" data-end=\"3520\"\u003eMaximum heating capacity at -20 °C: 11,300 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3520\" data-end=\"3523\"\u003e\u003cstrong data-start=\"3523\" data-end=\"3580\"\u003eMaximum heating capacity at -25 °C: 9,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"3580\" data-end=\"3583\"\u003e\u003cstrong data-start=\"3583\" data-end=\"3609\"\u003eEnergy Star V6.1: yes\u003c\/strong\u003e\u003cbr data-start=\"3609\" data-end=\"3612\"\u003e\u003cstrong data-start=\"3612\" data-end=\"3653\"\u003eIndoor airflow: 241 to 365 CFM\u003c\/strong\u003e\u003cbr data-start=\"3653\" data-end=\"3656\"\u003e\u003cstrong data-start=\"3656\" data-end=\"3721\"\u003eIndoor sound pressure: 47 \/ 41 \/ 38 \/ 33 \/ 29 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"3721\" data-end=\"3724\"\u003e\u003cstrong data-start=\"3724\" data-end=\"3769\"\u003eOutdoor sound pressure: 54 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"3769\" data-end=\"3772\"\u003e\u003cstrong data-start=\"3772\" data-end=\"3813\"\u003eVoltage: 208V \/ 230V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"3813\" data-end=\"3816\"\u003e\u003cstrong data-start=\"3816\" data-end=\"3860\"\u003eNominal cooling current: 3.5 A\u003c\/strong\u003e\u003cbr data-start=\"3860\" data-end=\"3863\"\u003e\u003cstrong data-start=\"3863\" data-end=\"3904\"\u003eNominal heating current: 3.46 A\u003c\/strong\u003e\u003cbr data-start=\"3904\" data-end=\"3907\"\u003e\u003cstrong data-start=\"3907\" data-end=\"3921\"\u003eMOP: 20 A\u003c\/strong\u003e\u003cbr data-start=\"3921\" data-end=\"3924\"\u003e\u003cstrong data-start=\"3924\" data-end=\"3938\"\u003eMCA: 14 A\u003c\/strong\u003e\u003cbr data-start=\"3938\" data-end=\"3941\"\u003e\u003cstrong data-start=\"3941\" data-end=\"4007\"\u003eRequired communication wire: 4\/14 copper multistrand 600V\u003c\/strong\u003e\u003cbr data-start=\"4007\" data-end=\"4010\"\u003e\u003cstrong data-start=\"4010\" data-end=\"4041\"\u003eLiquid piping: 1\/4 in\u003c\/strong\u003e\u003cbr data-start=\"4041\" data-end=\"4044\"\u003e\u003cstrong data-start=\"4044\" data-end=\"4071\"\u003eGas piping: 1\/2 in\u003c\/strong\u003e\u003cbr data-start=\"4071\" data-end=\"4074\"\u003e\u003cstrong data-start=\"4074\" data-end=\"4126\"\u003eMinimum-maximum piping length: 10 to 98.4 feet\u003c\/strong\u003e\u003cbr data-start=\"4126\" data-end=\"4129\"\u003e\u003cstrong data-start=\"4129\" data-end=\"4166\"\u003eMaximum elevation difference: 65 feet\u003c\/strong\u003e\u003cbr data-start=\"4166\" data-end=\"4169\"\u003e\u003cstrong data-start=\"4169\" data-end=\"4205\"\u003ePrecharge length: 25 feet\u003c\/strong\u003e\u003cbr data-start=\"4205\" data-end=\"4208\"\u003e\u003cstrong data-start=\"4208\" data-end=\"4259\"\u003eIndoor unit: 42 1\/16 × 12 5\/8 × 9 1\/16 in\u003c\/strong\u003e\u003cbr data-start=\"4259\" data-end=\"4262\"\u003e\u003cstrong data-start=\"4262\" data-end=\"4313\"\u003eOutdoor unit: 33 7\/8 × 25 1\/2 × 12 3\/16 in\u003c\/strong\u003e\u003cbr data-start=\"4313\" data-end=\"4316\"\u003e\u003cstrong data-start=\"4316\" data-end=\"4377\"\u003eCooling operating range: -15 °C to 48 °C\u003c\/strong\u003e\u003cbr data-start=\"4377\" data-end=\"4380\"\u003e\u003cstrong data-start=\"4380\" data-end=\"4437\"\u003eHeating operating range: -30 °C to 24 °C\u003c\/strong\u003e\u003cbr data-start=\"4437\" data-end=\"4440\"\u003e\u003cstrong data-start=\"4440\" data-end=\"4483\"\u003eZephyr basic warranty: 10 years parts\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"4485\" data-end=\"4886\"\u003eThis data is very important because it directly influences the feasibility of the project. For example, a 12,000 BTU heat pump with a \u003cstrong data-start=\"4628\" data-end=\"4643\"\u003eMCA of 14 A\u003c\/strong\u003e and a \u003cstrong data-start=\"4650\" data-end=\"4665\"\u003eMOP of 20 A\u003c\/strong\u003e must not be installed without electrical verification. Even if the nominal consumption is relatively low, the installation must comply with the manufacturer's requirements, electrical code, and good HVAC practices.\u003c\/p\u003e\n\u003chr data-start=\"4888\" data-end=\"4891\"\u003e\n\u003ch2 data-start=\"4893\" data-end=\"4948\"\u003eWhy refrigerant R454B is an important point\u003c\/h2\u003e\n\u003cp data-start=\"4950\" data-end=\"5284\"\u003eThe Zephyr UB32 series uses \u003cstrong data-start=\"4982\" data-end=\"5003\"\u003erefrigerant R454B\u003c\/strong\u003e, a new generation gas increasingly found in modern HVAC equipment. For the customer, the name of the refrigerant may seem secondary, but it plays an important role in the design of the device, its efficiency, and its market positioning.\u003c\/p\u003e\n\u003cp data-start=\"5286\" data-end=\"5715\"\u003eThe \u003cstrong data-start=\"5289\" data-end=\"5298\"\u003eR454B\u003c\/strong\u003e is part of the transition to refrigerants with a lower environmental impact than several older gases used in the industry. For a residential or light commercial installation, this means that the choice of equipment must be made seriously, but also that the installation must be carried out by a team that understands the technical requirements of the new generations of heat pumps.\u003c\/p\u003e\n\u003cp data-start=\"5717\" data-end=\"6165\"\u003eAt AirGreen, we pay special attention to the steps that ensure system reliability: \u003cstrong data-start=\"5826\" data-end=\"5858\"\u003eproperly sized piping\u003c\/strong\u003e, \u003cstrong data-start=\"5860\" data-end=\"5882\"\u003eclean flares\u003c\/strong\u003e, \u003cstrong data-start=\"5884\" data-end=\"5905\"\u003eleak testing\u003c\/strong\u003e, \u003cstrong data-start=\"5907\" data-end=\"5933\"\u003eadequate vacuum pulling\u003c\/strong\u003e, \u003cstrong data-start=\"5935\" data-end=\"5970\"\u003erespecting maximum lengths\u003c\/strong\u003e, \u003cstrong data-start=\"5972\" data-end=\"5999\"\u003eelectrical verification\u003c\/strong\u003e, and \u003cstrong data-start=\"6003\" data-end=\"6030\"\u003ecomplete start-up\u003c\/strong\u003e. A modern heat pump like the ZE-12UB32 can offer excellent performance, but only if installed rigorously.\u003c\/p\u003e\n\u003chr data-start=\"6167\" data-end=\"6170\"\u003e\n\u003ch2 data-start=\"6172\" data-end=\"6214\"\u003eHeating performance down to -30 °C\u003c\/h2\u003e\n\u003cp data-start=\"6216\" data-end=\"6457\"\u003eThe brochure presents the Zephyr UB32 as a heat pump capable of operating in heating mode down to \u003cstrong data-start=\"6318\" data-end=\"6328\"\u003e-30 °C\u003c\/strong\u003e. This is an important point for homeowners in Greater Montreal, where winters can be long, damp, and very variable.\u003c\/p\u003e\n\u003cp data-start=\"6459\" data-end=\"6834\"\u003eFor the \u003cstrong data-start=\"6474\" data-end=\"6487\"\u003eZE-12UB32\u003c\/strong\u003e model, the technical sheet indicates a heating capacity of \u003cstrong data-start=\"6545\" data-end=\"6570\"\u003e12,200 BTU\/h at 8.3 °C\u003c\/strong\u003e, a nominal capacity of \u003cstrong data-start=\"6597\" data-end=\"6623\"\u003e13,000 BTU\/h at -8.3 °C\u003c\/strong\u003e, a maximum capacity of \u003cstrong data-start=\"6650\" data-end=\"6675\"\u003e12,200 BTU\/h at -15 °C\u003c\/strong\u003e, \u003cstrong data-start=\"6680\" data-end=\"6705\"\u003e11,300 BTU\/h at -20 °C\u003c\/strong\u003e, and \u003cstrong data-start=\"6713\" data-end=\"6737\"\u003e9,000 BTU\/h at -25 °C\u003c\/strong\u003e. These figures help better understand the actual behavior of the unit during winter.\u003c\/p\u003e\n\u003cp data-start=\"6836\" data-end=\"7270\"\u003eHowever, it is important to clearly explain what “heating down to -30 °C” means. It does not mean that a heat pump always provides the same power at all temperatures. Generally, the lower the outside temperature, the more the available capacity can decrease. That’s why the house must be evaluated: insulation, windows, air infiltration, wind exposure, area, ceiling height, and existing heating.\u003c\/p\u003e\n\u003cp data-start=\"7272\" data-end=\"7583\"\u003eIn a well-insulated home, a \u003cstrong data-start=\"7305\" data-end=\"7338\"\u003e12,000 BTU wall-mounted heat pump\u003c\/strong\u003e can significantly reduce the use of electric baseboards in the served area. In an older or highly exposed building, it can still be very useful, but supplemental heating may be necessary on the coldest days.\u003c\/p\u003e\n\u003cp data-start=\"7585\" data-end=\"7818\"\u003eAt AirGreen, we prefer to be clear from the start: \u003cstrong data-start=\"7643\" data-end=\"7750\"\u003ethe ZE-12UB32 is an excellent supplemental or primary heating solution for a well-chosen area\u003c\/strong\u003e, but the result always depends on the installation and the building.\u003c\/p\u003e\n\u003chr data-start=\"7820\" data-end=\"7823\"\u003e\n\u003ch2 data-start=\"7825\" data-end=\"7880\"\u003eHigh energy efficiency: up to 30 SEER2\u003c\/h2\u003e\n\u003cp data-start=\"7882\" data-end=\"8239\"\u003eOne of the major advantages of the \u003cstrong data-start=\"7918\" data-end=\"7931\"\u003eZE-12UB32\u003c\/strong\u003e model is its cooling efficiency. The technical sheet indicates a \u003cstrong data-start=\"7999\" data-end=\"8014\"\u003eSEER2 of 30\u003c\/strong\u003e, which is an excellent level for a 12,000 BTU wall-mounted heat pump. SEER2 measures seasonal cooling efficiency. The higher the value, the more efficient the device is over a cooling season.\u003c\/p\u003e\n\u003cp data-start=\"8241\" data-end=\"8655\"\u003eThe model also shows an \u003cstrong data-start=\"8268\" data-end=\"8288\"\u003eHSPF2 IV of 11.8\u003c\/strong\u003e, indicating good seasonal heating efficiency. Its \u003cstrong data-start=\"8356\" data-end=\"8379\"\u003eCOP of 4.6 at 8.3 °C\u003c\/strong\u003e means that, under these conditions, the heat pump can produce much more thermal energy than the electricity it consumes. Even at \u003cstrong data-start=\"8520\" data-end=\"8530\"\u003e-15 °C\u003c\/strong\u003e, the sheet indicates a \u003cstrong data-start=\"8552\" data-end=\"8567\"\u003eCOP of 2.25\u003c\/strong\u003e, showing that the device maintains interesting efficiency at low temperatures.\u003c\/p\u003e\n\u003cp data-start=\"8657\" data-end=\"9060\"\u003eFor an owner, these figures mean one simple thing: \u003cstrong data-start=\"8724\" data-end=\"8793\"\u003ea well-used heat pump can reduce the energy bill\u003c\/strong\u003e, especially when it replaces part of the direct electric heating. However, the actual savings depend on several factors: set temperature, insulation, usage habits, operating time, indoor unit location, and maintenance.\u003c\/p\u003e\n\u003cp data-start=\"9062\" data-end=\"9242\"\u003eThe \u003cstrong data-start=\"9079\" data-end=\"9099\"\u003eEnergy Star V6.1\u003c\/strong\u003e certification indicated on the sheet is also a positive point, as it confirms that the model meets recognized energy efficiency criteria.\u003c\/p\u003e\n\u003chr data-start=\"9244\" data-end=\"9247\"\u003e\n\u003ch2 data-start=\"9249\" data-end=\"9305\"\u003eIndoor comfort, silent mode, and 4D air distribution\u003c\/h2\u003e\n\u003cp data-start=\"9307\" data-end=\"9682\"\u003eThe brochure highlights several features designed to improve daily comfort. Among the important elements are \u003cstrong data-start=\"9443\" data-end=\"9456\"\u003enight mode\u003c\/strong\u003e, \u003cstrong data-start=\"9461\" data-end=\"9477\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"9482\" data-end=\"9496\"\u003eiFeel mode\u003c\/strong\u003e, \u003cstrong data-start=\"9501\" data-end=\"9521\"\u003equick start\u003c\/strong\u003e, \u003cstrong data-start=\"9526\" data-end=\"9543\"\u003e24-hour timer\u003c\/strong\u003e, \u003cstrong data-start=\"9548\" data-end=\"9572\"\u003ebase heating\u003c\/strong\u003e, \u003cstrong data-start=\"9577\" data-end=\"9605\"\u003ecompressor heating\u003c\/strong\u003e, \u003cstrong data-start=\"9610\" data-end=\"9632\"\u003etwo-sided drain\u003c\/strong\u003e, and \u003cstrong data-start=\"9639\" data-end=\"9681\"\u003eauto-adaptive voltage technology\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"9684\" data-end=\"10040\"\u003eThe \u003cstrong data-start=\"9687\" data-end=\"9701\"\u003eiFeel mode\u003c\/strong\u003e is particularly interesting because it allows the heat pump to better adjust comfort based on the temperature sensed around the remote control, rather than just around the wall unit. In a room where the temperature varies between the installation wall and the living area, this feature can improve comfort accuracy.\u003c\/p\u003e\n\u003cp data-start=\"10042\" data-end=\"10474\"\u003eThe brochure also mentions \u003cstrong data-start=\"10074\" data-end=\"10101\"\u003eautomatic oscillation\u003c\/strong\u003e and a \u003cstrong data-start=\"10108\" data-end=\"10119\"\u003e4D mode\u003c\/strong\u003e, designed to better distribute air in the room. This helps reduce cold or hot spots and achieve a more uniform temperature. For a wall-mounted heat pump, air distribution is essential: a powerful but poorly directed unit can create discomfort, while a well-configured unit can make the room much more comfortable.\u003c\/p\u003e\n\u003cp data-start=\"10476\" data-end=\"10791\"\u003eThe indoor noise level is also an important advantage. The sheet indicates an indoor sound pressure of \u003cstrong data-start=\"10591\" data-end=\"10623\"\u003e47 \/ 41 \/ 38 \/ 33 \/ 29 dB(A)\u003c\/strong\u003e depending on the speed, including silent mode. This makes the \u003cstrong data-start=\"10681\" data-end=\"10694\"\u003eZE-12UB32\u003c\/strong\u003e suitable for a bedroom, office, living room, or space where noise must remain discreet.\u003c\/p\u003e\n\u003chr data-start=\"10793\" data-end=\"10796\"\u003e\n\u003ch2 data-start=\"10798\" data-end=\"10857\"\u003eHVAC installation: details to check before purchase\u003c\/h2\u003e\n\u003cp data-start=\"10859\" data-end=\"11043\"\u003eA wall-mounted heat pump is not chosen solely based on the number of BTUs. For the \u003cstrong data-start=\"10949\" data-end=\"10962\"\u003eZE-12UB32\u003c\/strong\u003e model, we always check several elements before confirming an installation.\u003c\/p\u003e\n\u003cp data-start=\"11045\" data-end=\"11328\"\u003e\u003cstrong data-start=\"11045\" data-end=\"11079\"\u003eThe actual area to be treated\u003c\/strong\u003e is the first point. A 12,000 BTU unit may be ideal for a main room, a condo, or a semi-open area, but it may be too powerful for a small, well-insulated bedroom or insufficient for a large, very windowed open area.\u003c\/p\u003e\n\u003cp data-start=\"11330\" data-end=\"11577\"\u003e\u003cstrong data-start=\"11330\" data-end=\"11357\"\u003eCeiling height\u003c\/strong\u003e also changes the calculation. A room with 8-foot ceilings does not have the same air volume as a space with a cathedral ceiling. The heat load can be very different, even if the floor area seems similar.\u003c\/p\u003e\n\u003cp data-start=\"11579\" data-end=\"11848\"\u003e\u003cstrong data-start=\"11579\" data-end=\"11605\"\u003eSun exposure\u003c\/strong\u003e is another factor. A room facing south or west with large windows may require more cooling capacity. In some condos in Montreal or Laval, the solar load in the afternoon can be higher than expected.\u003c\/p\u003e\n\u003cp data-start=\"11850\" data-end=\"12131\"\u003e\u003cstrong data-start=\"11850\" data-end=\"11893\"\u003eThe building’s insulation and airtightness\u003c\/strong\u003e strongly influence heating performance. A recent, well-insulated house will allow the heat pump to maintain comfort more easily. An older house with air leaks will require a more careful analysis.\u003c\/p\u003e\n\u003cp data-start=\"12133\" data-end=\"12385\"\u003e\u003cstrong data-start=\"12133\" data-end=\"12172\"\u003eThe location of the indoor unit\u003c\/strong\u003e is crucial. The unit must blow air toward the area to be treated, without creating a permanent direct draft on the occupants. It must also be accessible for maintenance and installed on an appropriate wall.\u003c\/p\u003e\n\u003cp data-start=\"12387\" data-end=\"12560\"\u003e\u003cstrong data-start=\"12387\" data-end=\"12426\"\u003eThe location of the outdoor unit\u003c\/strong\u003e must respect the necessary clearances, stability, drainage, noise, snow, ice, and future access for service.\u003c\/p\u003e\n\u003cp data-start=\"12562\" data-end=\"12744\"\u003eAt AirGreen, we know that a good installation starts even before taking out the tools. Planning avoids unpleasant surprises and ensures a lasting result.\u003c\/p\u003e\n\u003chr data-start=\"12746\" data-end=\"12749\"\u003e\n\u003ch2 data-start=\"12751\" data-end=\"12804\"\u003ePiping, electricity, and project compatibility\u003c\/h2\u003e\n\u003cp data-start=\"12806\" data-end=\"13126\"\u003eThe \u003cstrong data-start=\"12809\" data-end=\"12822\"\u003eZE-12UB32\u003c\/strong\u003e uses piping of \u003cstrong data-start=\"12849\" data-end=\"12875\"\u003e1\/4 inch for liquid\u003c\/strong\u003e and \u003cstrong data-start=\"12879\" data-end=\"12901\"\u003e1\/2 inch for gas\u003c\/strong\u003e. This information is very important in replacement projects. When a customer already has an old heat pump, they may want to reuse the existing lines. This is not always possible or recommended.\u003c\/p\u003e\n\u003cp data-start=\"13128\" data-end=\"13441\"\u003eBefore reusing piping, we check the diameter, line condition, length, type of old refrigerant, accessibility, and cleanliness of the path. In many cases, replacing the lines is the best option to protect the performance, warranty, and durability of the new system.\u003c\/p\u003e\n\u003cp data-start=\"13443\" data-end=\"13706\"\u003eThe technical sheet indicates a piping length of \u003cstrong data-start=\"13500\" data-end=\"13519\"\u003e10 to 98.4 feet\u003c\/strong\u003e, with a preload length of \u003cstrong data-start=\"13555\" data-end=\"13567\"\u003e25 feet\u003c\/strong\u003e and a maximum elevation difference of \u003cstrong data-start=\"13601\" data-end=\"13613\"\u003e65 feet\u003c\/strong\u003e. These specifications must be followed to avoid performance or reliability issues.\u003c\/p\u003e\n\u003cp data-start=\"13708\" data-end=\"14010\"\u003eElectrically, the model operates at \u003cstrong data-start=\"13756\" data-end=\"13787\"\u003e208V \/ 230V, 60 Hz, 1 phase\u003c\/strong\u003e. The specification mentions a \u003cstrong data-start=\"13811\" data-end=\"13826\"\u003eMCA of 14 A\u003c\/strong\u003e and a \u003cstrong data-start=\"13833\" data-end=\"13848\"\u003eMOP of 20 A\u003c\/strong\u003e. This means the electrical panel must be checked before installation. The required communication wire specified is \u003cstrong data-start=\"13975\" data-end=\"14009\"\u003e4\/14 copper stranded 600V\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"14012\" data-end=\"14330\"\u003eIn older homes in Montreal, Longueuil, or certain areas of Laval, the electrical panel may already be full or lack space. A thorough estimate must therefore include this check. An efficient heat pump cannot be properly installed if the electrical supply is not compliant.\u003c\/p\u003e\n\u003chr data-start=\"14332\" data-end=\"14335\"\u003e\n\u003ch2 data-start=\"14337\" data-end=\"14393\"\u003eMaintenance and durability of the Zephyr UB32 heat pump\u003c\/h2\u003e\n\u003cp data-start=\"14395\" data-end=\"14776\"\u003eA high-performance wall heat pump like the \u003cstrong data-start=\"14439\" data-end=\"14452\"\u003eZE-12UB32\u003c\/strong\u003e must be properly maintained to retain its efficiency. Even though the unit has convenient features like \u003cstrong data-start=\"14578\" data-end=\"14603\"\u003eautomatic cleaning\u003c\/strong\u003e, \u003cstrong data-start=\"14608\" data-end=\"14633\"\u003eautomatic defrosting\u003c\/strong\u003e, \u003cstrong data-start=\"14638\" data-end=\"14674\"\u003ediffuser position memory\u003c\/strong\u003e, \u003cstrong data-start=\"14679\" data-end=\"14707\"\u003ereversible drain hose\u003c\/strong\u003e, and \u003cstrong data-start=\"14713\" data-end=\"14732\"\u003eLED attenuator\u003c\/strong\u003e, this does not replace regular maintenance.\u003c\/p\u003e\n\u003cp data-start=\"14778\" data-end=\"14807\"\u003eWe especially recommend:\u003c\/p\u003e\n\u003cp data-start=\"14809\" data-end=\"15178\"\u003e\u003cstrong data-start=\"14809\" data-end=\"14847\"\u003eClean the filters regularly\u003c\/strong\u003e\u003cbr data-start=\"14847\" data-end=\"14850\"\u003e\u003cstrong data-start=\"14850\" data-end=\"14886\"\u003eKeep the indoor unit clean\u003c\/strong\u003e\u003cbr data-start=\"14886\" data-end=\"14889\"\u003e\u003cstrong data-start=\"14889\" data-end=\"14928\"\u003eMonitor the condensation drain\u003c\/strong\u003e\u003cbr data-start=\"14928\" data-end=\"14931\"\u003e\u003cstrong data-start=\"14931\" data-end=\"15001\"\u003eClear the outdoor unit of snow, leaves, and debris\u003c\/strong\u003e\u003cbr data-start=\"15001\" data-end=\"15004\"\u003e\u003cstrong data-start=\"15004\" data-end=\"15059\"\u003eCheck the condition of the outdoor base before winter\u003c\/strong\u003e\u003cbr data-start=\"15059\" data-end=\"15062\"\u003e\u003cstrong data-start=\"15062\" data-end=\"15116\"\u003eHave the unit inspected if performance decreases\u003c\/strong\u003e\u003cbr data-start=\"15116\" data-end=\"15119\"\u003e\u003cstrong data-start=\"15119\" data-end=\"15178\"\u003eSchedule professional cleaning when necessary\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"15180\" data-end=\"15498\"\u003eA wall unit naturally accumulates dust, especially when frequently used for cooling. A dirty filter reduces airflow, increases consumption, and can cause unusual odors or noises. An outdoor unit blocked by snow or debris can also lose performance.\u003c\/p\u003e\n\u003cp data-start=\"15500\" data-end=\"15799\"\u003eWith proper maintenance, the heat pump can maintain an excellent level of comfort for many years. The basic Zephyr warranty indicated in the brochure is \u003cstrong data-start=\"15670\" data-end=\"15687\"\u003e10 years parts\u003c\/strong\u003e, which is a significant advantage for homeowners looking to invest in a durable solution.\u003c\/p\u003e\n\u003chr data-start=\"15801\" data-end=\"15804\"\u003e\n\u003ch2 data-start=\"15806\" data-end=\"15862\"\u003eWhy choose AirGreen to install the ZE-12UB32\u003c\/h2\u003e\n\u003cp data-start=\"15864\" data-end=\"16215\"\u003eAirGreen installs HVAC systems in Greater Montreal, including \u003cstrong data-start=\"15933\" data-end=\"15992\"\u003eMontreal, Laval, Longueuil, the South Shore, and the North Shore\u003c\/strong\u003e. Our team understands the realities of Quebec homes: condos with limited access, Montreal plexes, single-family homes, bungalows, recent constructions, light commercial spaces, and replacements of old heat pumps.\u003c\/p\u003e\n\u003cp data-start=\"16217\" data-end=\"16496\"\u003eFor a model like the \u003cstrong data-start=\"16241\" data-end=\"16261\"\u003eZephyr ZE-12UB32\u003c\/strong\u003e, our role is to verify that the device truly fits the project. We analyze the space, location, electrical constraints, piping, drainage, noise, maintenance access, and client expectations.\u003c\/p\u003e\n\u003cp data-start=\"16498\" data-end=\"16534\"\u003eChoosing AirGreen means benefiting from:\u003c\/p\u003e\n\u003cp data-start=\"16536\" data-end=\"16984\"\u003e\u003cstrong data-start=\"16536\" data-end=\"16584\"\u003efrom a clear evaluation before installation\u003c\/strong\u003e\u003cbr data-start=\"16584\" data-end=\"16587\"\u003e\u003cstrong data-start=\"16587\" data-end=\"16631\"\u003efrom a recommendation tailored to the building\u003c\/strong\u003e\u003cbr data-start=\"16631\" data-end=\"16634\"\u003e\u003cstrong data-start=\"16634\" data-end=\"16691\"\u003efrom an installation compliant with good HVAC practices\u003c\/strong\u003e\u003cbr data-start=\"16691\" data-end=\"16694\"\u003e\u003cstrong data-start=\"16694\" data-end=\"16736\"\u003efrom a thorough electrical inspection\u003c\/strong\u003e\u003cbr data-start=\"16736\" data-end=\"16739\"\u003e\u003cstrong data-start=\"16739\" data-end=\"16807\"\u003efrom thoughtful positioning of the indoor and outdoor units\u003c\/strong\u003e\u003cbr data-start=\"16807\" data-end=\"16810\"\u003e\u003cstrong data-start=\"16810\" data-end=\"16865\"\u003efrom an honest explanation of winter performance\u003c\/strong\u003e\u003cbr data-start=\"16865\" data-end=\"16868\"\u003e\u003cstrong data-start=\"16868\" data-end=\"16906\"\u003efrom a structured after-sales service\u003c\/strong\u003e\u003cbr data-start=\"16906\" data-end=\"16909\"\u003e\u003cstrong data-start=\"16909\" data-end=\"16984\"\u003efrom a team experienced with wall-mounted, central, and multi-zone heat pumps\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"16986\" data-end=\"17439\"\u003eThe \u003cstrong data-start=\"16989\" data-end=\"17021\"\u003eZephyr UB32 R454B 12,000 BTU\u003c\/strong\u003e is a very interesting solution for customers who want an efficient, quiet device capable of providing comfort year-round. Its \u003cstrong data-start=\"17169\" data-end=\"17184\"\u003eSEER2 of 30\u003c\/strong\u003e, \u003cstrong data-start=\"17190\" data-end=\"17207\"\u003eHSPF2 of 11.8\u003c\/strong\u003e, operation down to \u003cstrong data-start=\"17236\" data-end=\"17246\"\u003e-30 °C\u003c\/strong\u003e, \u003cstrong data-start=\"17252\" data-end=\"17273\"\u003eR454B refrigerant\u003c\/strong\u003e, outdoor noise level of \u003cstrong data-start=\"17306\" data-end=\"17318\"\u003e54 dB(A)\u003c\/strong\u003e, and \u003cstrong data-start=\"17337\" data-end=\"17354\"\u003e10-year parts warranty\u003c\/strong\u003e make it a solid choice for many residential and light commercial projects.\u003c\/p\u003e\n\u003cp data-start=\"17441\" data-end=\"17710\"\u003eHowever, as with any heat pump, the result depends heavily on the installation. Proper selection, good placement, and careful startup make all the difference between a simply functional machine and a truly comfortable solution.\u003c\/p\u003e\n\u003cp data-start=\"17712\" data-end=\"18028\"\u003eTo get a clear quote for the \u003cstrong data-start=\"17755\" data-end=\"17794\"\u003eZephyr ZE-12UB32 wall-mounted heat pump\u003c\/strong\u003e, check the feasibility of your installation, or compare this model with other HVAC options, contact AirGreen. Our team will help you choose the right solution based on your building, budget, and comfort goals.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665927553316,"sku":"ZE-12UB32I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRUB32R454BGRANDMONTREAL_f60ad527-635e-4f27-8954-fe5e76a3c78b.png?v=1783695891"},{"product_id":"thermopompe-murale-zephyr-ub32-r454b-15000-btu-montreal-laval-rive-sud","title":"ZEPHYR UB32 R454B Wall Heat Pump | 15000 BTU | Montreal, Laval, South Shore","description":"\u003ch1 data-start=\"119\" data-end=\"224\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"121\" data-end=\"224\"\u003eZephyr ZE-15UB32 Wall-Mounted Heat Pump — 15,000 BTU, R454B, high efficiency and comfort down to -30 °C\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003cp data-start=\"1065\" data-end=\"1656\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"1068\" data-end=\"1107\"\u003eZephyr ZE-15UB32 Wall-Mounted Heat Pump\u003c\/strong\u003e is a modern HVAC solution designed for homeowners seeking an efficient, quiet device capable of providing stable comfort both in summer and winter. With its \u003cstrong data-start=\"1303\" data-end=\"1334\"\u003e15,000 BTU cooling capacity\u003c\/strong\u003e, operation with \u003cstrong data-start=\"1358\" data-end=\"1379\"\u003eR454B refrigerant\u003c\/strong\u003e, high energy efficiency, and heating capacity down to \u003cstrong data-start=\"1449\" data-end=\"1459\"\u003e-30 °C\u003c\/strong\u003e, this model represents a very interesting option for houses, condos, plexes, offices, and spacious residential areas in Montreal, Laval, Longueuil, the South Shore, and the North Shore.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1658\" data-end=\"2196\"\u003eAt AirGreen, we recommend this type of wall-mounted heat pump when the need goes beyond simple supplemental cooling. The \u003cstrong data-start=\"1787\" data-end=\"1807\"\u003eZephyr ZE-15UB32\u003c\/strong\u003e is designed to provide serious comfort in a living area, a living room, an office, an open space, a finished basement, or a zone where a 9,000 or 12,000 BTU unit might sometimes be insufficient. It combines \u003cstrong data-start=\"2022\" data-end=\"2114\"\u003epower, energy efficiency, low-temperature heating, and quiet operation\u003c\/strong\u003e, making it a relevant choice for many residential projects in Quebec.\u003c\/p\u003e\n\u003cp data-start=\"2198\" data-end=\"2813\"\u003eThis model stands out notably for its \u003cstrong data-start=\"2239\" data-end=\"2256\"\u003eSEER2 of 25.6\u003c\/strong\u003e, its \u003cstrong data-start=\"2262\" data-end=\"2279\"\u003eHSPF2 of 11.1\u003c\/strong\u003e, its \u003cstrong data-start=\"2285\" data-end=\"2324\"\u003eoutdoor noise level of 54 dB(A)\u003c\/strong\u003e, its airflow of \u003cstrong data-start=\"2345\" data-end=\"2362\"\u003e241 to 365 CFM\u003c\/strong\u003e, its heating mode down to \u003cstrong data-start=\"2391\" data-end=\"2401\"\u003e-30 °C\u003c\/strong\u003e, and its cooling mode down to \u003cstrong data-start=\"2436\" data-end=\"2446\"\u003e-15 °C\u003c\/strong\u003e. The Zephyr UB32 brochure also lists features such as \u003cstrong data-start=\"2509\" data-end=\"2522\"\u003enight mode\u003c\/strong\u003e, \u003cstrong data-start=\"2527\" data-end=\"2543\"\u003esilent mode\u003c\/strong\u003e, \u003cstrong data-start=\"2548\" data-end=\"2562\"\u003eiFeel mode\u003c\/strong\u003e, \u003cstrong data-start=\"2567\" data-end=\"2587\"\u003equick start\u003c\/strong\u003e, \u003cstrong data-start=\"2592\" data-end=\"2613\"\u003ebase heating\u003c\/strong\u003e, \u003cstrong data-start=\"2618\" data-end=\"2646\"\u003ecompressor heating\u003c\/strong\u003e, \u003cstrong data-start=\"2651\" data-end=\"2669\"\u003e24-hour timer\u003c\/strong\u003e, \u003cstrong data-start=\"2674\" data-end=\"2696\"\u003etwo-sided drain\u003c\/strong\u003e, \u003cstrong data-start=\"2701\" data-end=\"2712\"\u003e4D mode\u003c\/strong\u003e, \u003cstrong data-start=\"2717\" data-end=\"2742\"\u003eautomatic cleaning\u003c\/strong\u003e, and \u003cstrong data-start=\"2749\" data-end=\"2774\"\u003eautomatic defrosting\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2 data-start=\"2815\" data-end=\"2891\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2818\" data-end=\"2891\"\u003e1. A 15,000 BTU wall-mounted heat pump designed for comfort in Quebec\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"2893\" data-end=\"3292\"\u003eThe \u003cstrong data-start=\"2896\" data-end=\"2916\"\u003eZephyr ZE-15UB32\u003c\/strong\u003e offers a cooling capacity of \u003cstrong data-start=\"2958\" data-end=\"2974\"\u003e15,000 BTU\/h\u003c\/strong\u003e at 35 °C and a heating capacity of \u003cstrong data-start=\"3015\" data-end=\"3031\"\u003e15,200 BTU\/h\u003c\/strong\u003e at 8.3 °C. This power makes it especially suitable for medium to large rooms, open areas, spacious condos, well-insulated homes, or living spaces that require more reserve than a standard small wall unit.\u003c\/p\u003e\n\u003cp data-start=\"3294\" data-end=\"3846\"\u003eIn Greater Montreal, choosing a heat pump should never be based solely on the BTU rating. A \u003cstrong data-start=\"3423\" data-end=\"3437\"\u003e15,000 BTU\u003c\/strong\u003e unit may be perfect for a large open room but too powerful for a closed or poorly ventilated space. At AirGreen, we always assess the actual setup: \u003cstrong data-start=\"3647\" data-end=\"3845\"\u003earea, ceiling height, insulation, window orientation, sun exposure, air circulation, indoor location, distance to the outdoor unit, and electrical constraints\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"3848\" data-end=\"4262\"\u003eA properly sized heat pump provides a more stable temperature, better dehumidification in summer, and more efficient heating in winter. Conversely, a poorly chosen unit can cause short cycles, drafts, or uneven comfort. That’s why the \u003cstrong data-start=\"4149\" data-end=\"4162\"\u003eZE-15UB32\u003c\/strong\u003e must be carefully selected based on the building, not just the rated capacity.\u003c\/p\u003e\n\u003ch2 data-start=\"4264\" data-end=\"4337\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"4267\" data-end=\"4337\"\u003e2. Important technical features of the ZE-15UB32 model\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"4339\" data-end=\"4433\"\u003eHere are the key details to remember for the \u003cstrong data-start=\"4392\" data-end=\"4431\"\u003eZephyr ZE-15UB32 Wall-Mounted Heat Pump\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp data-start=\"4435\" data-end=\"5903\"\u003e• \u003cstrong data-start=\"4437\" data-end=\"4456\"\u003eBrand: Zephyr\u003c\/strong\u003e\u003cbr data-start=\"4456\" data-end=\"4459\"\u003e• \u003cstrong data-start=\"4461\" data-end=\"4477\"\u003eSeries: UB32\u003c\/strong\u003e\u003cbr data-start=\"4477\" data-end=\"4480\"\u003e• \u003cstrong data-start=\"4482\" data-end=\"4504\"\u003eModel: ZE-15UB32\u003c\/strong\u003e\u003cbr data-start=\"4504\" data-end=\"4507\"\u003e• \u003cstrong data-start=\"4509\" data-end=\"4538\"\u003eType: wall-mounted heat pump\u003c\/strong\u003e\u003cbr data-start=\"4538\" data-end=\"4541\"\u003e• \u003cstrong data-start=\"4543\" data-end=\"4566\"\u003eRefrigerant: R454B\u003c\/strong\u003e\u003cbr data-start=\"4566\" data-end=\"4569\"\u003e• \u003cstrong data-start=\"4571\" data-end=\"4625\"\u003eCooling capacity at 35 °C: 15,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4625\" data-end=\"4628\"\u003e• \u003cstrong data-start=\"4630\" data-end=\"4679\"\u003eHeating capacity at 8.3 °C: 15,200 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4679\" data-end=\"4682\"\u003e• \u003cstrong data-start=\"4684\" data-end=\"4700\"\u003eSEER2: 25.6\u003c\/strong\u003e\u003cbr data-start=\"4700\" data-end=\"4703\"\u003e• \u003cstrong data-start=\"4705\" data-end=\"4721\"\u003eHSPF2: 11.1\u003c\/strong\u003e\u003cbr data-start=\"4721\" data-end=\"4724\"\u003e• \u003cstrong data-start=\"4726\" data-end=\"4748\"\u003eEER2: 13.65 BTU\/W\u003c\/strong\u003e\u003cbr data-start=\"4748\" data-end=\"4751\"\u003e• \u003cstrong data-start=\"4753\" data-end=\"4788\"\u003eHeating COP at 8.3 °C: 4.2\u003c\/strong\u003e\u003cbr data-start=\"4788\" data-end=\"4791\"\u003e• \u003cstrong data-start=\"4793\" data-end=\"4831\"\u003eHeating at -8.3 °C: 13,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4831\" data-end=\"4834\"\u003e• \u003cstrong data-start=\"4836\" data-end=\"4894\"\u003eMaximum heating capacity at -15 °C: 12,200 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4894\" data-end=\"4897\"\u003e• \u003cstrong data-start=\"4899\" data-end=\"4957\"\u003eMaximum heating capacity at -20 °C: 11,300 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"4957\" data-end=\"4960\"\u003e• \u003cstrong data-start=\"4962\" data-end=\"5019\"\u003eMaximum heating capacity at -25 °C: 9,000 BTU\/h\u003c\/strong\u003e\u003cbr data-start=\"5019\" data-end=\"5022\"\u003e• \u003cstrong data-start=\"5024\" data-end=\"5047\"\u003eCOP at -15 °C: 2.25\u003c\/strong\u003e\u003cbr data-start=\"5047\" data-end=\"5050\"\u003e• \u003cstrong data-start=\"5052\" data-end=\"5078\"\u003eEnergy Star V6.1: yes\u003c\/strong\u003e\u003cbr data-start=\"5078\" data-end=\"5081\"\u003e• \u003cstrong data-start=\"5083\" data-end=\"5114\"\u003eAirflow: 241 to 365 CFM\u003c\/strong\u003e\u003cbr data-start=\"5114\" data-end=\"5117\"\u003e• \u003cstrong data-start=\"5119\" data-end=\"5184\"\u003eIndoor sound pressure: 47 \/ 41 \/ 38 \/ 33 \/ 29 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"5184\" data-end=\"5187\"\u003e• \u003cstrong data-start=\"5189\" data-end=\"5234\"\u003eOutdoor sound pressure: 54 dB(A)\u003c\/strong\u003e\u003cbr data-start=\"5234\" data-end=\"5237\"\u003e• \u003cstrong data-start=\"5239\" data-end=\"5278\"\u003eVoltage: 208\/230 V, 60 Hz, 1 phase\u003c\/strong\u003e\u003cbr data-start=\"5278\" data-end=\"5281\"\u003e• \u003cstrong data-start=\"5283\" data-end=\"5328\"\u003eNominal cooling current: 4.95 A\u003c\/strong\u003e\u003cbr data-start=\"5328\" data-end=\"5331\"\u003e• \u003cstrong data-start=\"5333\" data-end=\"5373\"\u003eNominal heating current: 4.9 A\u003c\/strong\u003e\u003cbr data-start=\"5373\" data-end=\"5376\"\u003e• \u003cstrong data-start=\"5378\" data-end=\"5392\"\u003eMCA: 14 A\u003c\/strong\u003e\u003cbr data-start=\"5392\" data-end=\"5395\"\u003e• \u003cstrong data-start=\"5397\" data-end=\"5411\"\u003eMOP: 20 A\u003c\/strong\u003e\u003cbr data-start=\"5411\" data-end=\"5414\"\u003e• \u003cstrong data-start=\"5416\" data-end=\"5480\"\u003eCommunication wire required: 4\/14 copper stranded 600 V\u003c\/strong\u003e\u003cbr data-start=\"5480\" data-end=\"5483\"\u003e• \u003cstrong data-start=\"5485\" data-end=\"5511\"\u003eLiquid pipe: 1\/4 in\u003c\/strong\u003e\u003cbr data-start=\"5511\" data-end=\"5514\"\u003e• \u003cstrong data-start=\"5516\" data-end=\"5538\"\u003eGas pipe: 1\/2 in\u003c\/strong\u003e\u003cbr data-start=\"5538\" data-end=\"5541\"\u003e• \u003cstrong data-start=\"5543\" data-end=\"5595\"\u003ePipe length min-max: 10 to 98.4 feet\u003c\/strong\u003e\u003cbr data-start=\"5595\" data-end=\"5598\"\u003e• \u003cstrong data-start=\"5600\" data-end=\"5637\"\u003eMaximum elevation: 65 feet\u003c\/strong\u003e\u003cbr data-start=\"5637\" data-end=\"5640\"\u003e• \u003cstrong data-start=\"5642\" data-end=\"5678\"\u003ePrecharge length: 25 feet\u003c\/strong\u003e\u003cbr data-start=\"5678\" data-end=\"5681\"\u003e• \u003cstrong data-start=\"5683\" data-end=\"5734\"\u003eIndoor unit: 42 1\/16 × 12 5\/8 × 9 1\/16 in\u003c\/strong\u003e\u003cbr data-start=\"5734\" data-end=\"5737\"\u003e• \u003cstrong data-start=\"5739\" data-end=\"5790\"\u003eOutdoor unit: 33 7\/8 × 25 1\/2 × 12 3\/16 in\u003c\/strong\u003e\u003cbr data-start=\"5790\" data-end=\"5793\"\u003e• \u003cstrong data-start=\"5795\" data-end=\"5831\"\u003eBasic warranty: 10 years parts\u003c\/strong\u003e\u003cbr data-start=\"5831\" data-end=\"5834\"\u003e• \u003cstrong data-start=\"5836\" data-end=\"5903\"\u003eLabor warranty: available according to the distributor\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"5905\" data-end=\"6160\"\u003eThis information is not just technical details. They directly influence the feasibility of the project, the installation method, the choice of location, electrical compatibility, and the actual performance of the unit once installed.\u003c\/p\u003e\n\u003ch2 data-start=\"6162\" data-end=\"6234\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"6165\" data-end=\"6234\"\u003e3. Serious energy efficiency: SEER2 25.6 and HSPF2 11.1\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"6236\" data-end=\"6570\"\u003eThe \u003cstrong data-start=\"6239\" data-end=\"6259\"\u003eZephyr ZE-15UB32\u003c\/strong\u003e boasts a \u003cstrong data-start=\"6271\" data-end=\"6288\"\u003eSEER2 of 25.6\u003c\/strong\u003e, indicating excellent seasonal cooling efficiency. For an owner in Montreal, Laval, Longueuil, on the South Shore or North Shore, this means the unit is designed to cool effectively during summer while limiting electricity consumption.\u003c\/p\u003e\n\u003cp data-start=\"6572\" data-end=\"6946\"\u003eIts \u003cstrong data-start=\"6576\" data-end=\"6593\"\u003eHSPF2 of 11.1\u003c\/strong\u003e is also an important indicator for heating. In Quebec, a heat pump is often used for much of the year, not just during heat waves. A good HSPF2 helps optimize seasonal heating performance and reduce the use of traditional electric heating when conditions allow.\u003c\/p\u003e\n\u003cp data-start=\"6948\" data-end=\"7285\"\u003eThe \u003cstrong data-start=\"6951\" data-end=\"6974\"\u003eCOP of 4.2 at 8.3 °C\u003c\/strong\u003e shows that the unit can produce several units of heat for each unit of electricity consumed under favorable conditions. Even at \u003cstrong data-start=\"7120\" data-end=\"7130\"\u003e-15 °C\u003c\/strong\u003e, the brochure indicates a \u003cstrong data-start=\"7155\" data-end=\"7170\"\u003eCOP of 2.25\u003c\/strong\u003e, confirming that this model maintains good efficiency even when the outside temperature drops.\u003c\/p\u003e\n\u003ch2 data-start=\"7287\" data-end=\"7368\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"7290\" data-end=\"7368\"\u003e4. Heating down to -30 °C: a real advantage for the Quebec climate\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"7370\" data-end=\"7613\"\u003eOne of the most important features of the \u003cstrong data-start=\"7414\" data-end=\"7427\"\u003eZE-15UB32\u003c\/strong\u003e is its ability to operate in heating mode down to \u003cstrong data-start=\"7479\" data-end=\"7489\"\u003e-30 °C\u003c\/strong\u003e. For Quebec homeowners, this is a major point, especially in areas where winters are cold and prolonged.\u003c\/p\u003e\n\u003cp data-start=\"7615\" data-end=\"7991\"\u003eIt is important to understand what this data means. A heat pump can operate at very low temperatures, but its heating capacity gradually decreases as the cold intensifies. The brochure indicates for this model a capacity of \u003cstrong data-start=\"7882\" data-end=\"7908\"\u003e13,000 BTU\/h at -8.3 °C\u003c\/strong\u003e, \u003cstrong data-start=\"7910\" data-end=\"7935\"\u003e12,200 BTU\/h at -15 °C\u003c\/strong\u003e, \u003cstrong data-start=\"7937\" data-end=\"7962\"\u003e11,300 BTU\/h at -20 °C\u003c\/strong\u003e, and \u003cstrong data-start=\"7966\" data-end=\"7990\"\u003e9,000 BTU\/h at -25 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"7993\" data-end=\"8446\"\u003eThese figures are important to assess true winter performance. In a well-insulated house, the ZE-15UB32 can cover a large part of the heating needs for an area. In an older, poorly insulated, or very windy house, supplementary heating may still be necessary on the coldest days. At AirGreen, we always explain this clearly before installation to avoid unrealistic expectations.\u003c\/p\u003e\n\u003ch2 data-start=\"8448\" data-end=\"8542\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"8451\" data-end=\"8542\"\u003e5. R454B refrigerant: a modern technology for new HVAC installations\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"8544\" data-end=\"8902\"\u003eThe \u003cstrong data-start=\"8547\" data-end=\"8567\"\u003eZephyr ZE-15UB32\u003c\/strong\u003e uses \u003cstrong data-start=\"8579\" data-end=\"8600\"\u003eR454B refrigerant\u003c\/strong\u003e, a new generation gas increasingly present in modern HVAC equipment. For the customer, the type of refrigerant may seem secondary, but it influences the design of the device, efficiency, installation requirements, and compliance with new industry practices.\u003c\/p\u003e\n\u003cp data-start=\"8904\" data-end=\"9211\"\u003eA device operating with \u003cstrong data-start=\"8932\" data-end=\"8941\"\u003eR454B\u003c\/strong\u003e must be installed with particular care. Best practices are essential: \u003cstrong data-start=\"9035\" data-end=\"9210\"\u003eclean connections, leak testing, thorough vacuuming, adherence to pipe length requirements, electrical verification, adequate clearances, and full commissioning\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"9213\" data-end=\"9471\"\u003eAt AirGreen, we believe that a modern heat pump must be paired with a modern installation. A high-performance machine can lose some of its efficiency if it is poorly installed, poorly positioned, or connected to inadequate piping.\u003c\/p\u003e\n\u003ch2 data-start=\"9473\" data-end=\"9550\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"9476\" data-end=\"9550\"\u003e6. Indoor comfort: 4D mode, iFeel, silence, and variable ventilation\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"9552\" data-end=\"9881\"\u003eThe Zephyr UB32 brochure highlights several features designed to improve daily comfort. The \u003cstrong data-start=\"9660\" data-end=\"9671\"\u003e4D mode\u003c\/strong\u003e allows better air distribution in the room thanks to a more complete automatic oscillation. This function helps reduce cold or hot spots and maintain a more uniform temperature.\u003c\/p\u003e\n\u003cp data-start=\"9883\" data-end=\"10207\"\u003eThe \u003cstrong data-start=\"9886\" data-end=\"9900\"\u003eiFeel mode\u003c\/strong\u003e is also interesting because it allows the heat pump to adjust its operation based on the temperature sensed near the remote control. This can improve comfort in rooms where the temperature near the indoor unit does not perfectly reflect the temperature in the occupied area.\u003c\/p\u003e\n\u003cp data-start=\"10209\" data-end=\"10530\"\u003eThe \u003cstrong data-start=\"10212\" data-end=\"10228\"\u003esilent mode\u003c\/strong\u003e and \u003cstrong data-start=\"10235\" data-end=\"10248\"\u003enight mode\u003c\/strong\u003e are useful for bedrooms, offices, living rooms, or spaces where noise level is important. With an indoor sound pressure level that can drop to \u003cstrong data-start=\"10408\" data-end=\"10436\"\u003e29 dB(A) in silent mode\u003c\/strong\u003e, the ZE-15UB32 can operate very quietly when conditions allow.\u003c\/p\u003e\n\u003cp data-start=\"10532\" data-end=\"10810\"\u003eVariable frequency technology also allows the unit to adjust its power in real time. Instead of operating only on an on-off basis, the heat pump modulates its output, which helps maintain more stable comfort and reduce temperature fluctuations.\u003c\/p\u003e\n\u003ch2 data-start=\"10812\" data-end=\"10871\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"10815\" data-end=\"10871\"\u003e7. HVAC installation: the details that make all the difference\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"10873\" data-end=\"11253\"\u003eA good wall-mounted heat pump installation is not just about mounting a unit on the wall and plugging it in. For a \u003cstrong data-start=\"10995\" data-end=\"11015\"\u003eZephyr ZE-15UB32\u003c\/strong\u003e, several details must be verified before work begins: \u003cstrong data-start=\"11076\" data-end=\"11252\"\u003eindoor unit location, outdoor unit location, piping route, drainage, clearances, electrical supply, and future maintenance access\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"11255\" data-end=\"11509\"\u003eThe indoor unit must be placed to effectively distribute air in the main area. A poor location can create drafts, uneven distribution, or an uncomfortable zone despite good technical capacity.\u003c\/p\u003e\n\u003cp data-start=\"11511\" data-end=\"11896\"\u003eThe outdoor unit must be installed on a stable base, with sufficient clearances to ensure good air circulation. In Quebec, you also need to consider snow, ice, roof water, natural drainage, and access for maintenance. A poorly planned outdoor installation can reduce the lifespan of the unit or impair its performance during winter.\u003c\/p\u003e\n\u003ch2 data-start=\"11898\" data-end=\"11970\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"11901\" data-end=\"11970\"\u003e8. Piping, electrical supply, and technical compatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"11972\" data-end=\"12281\"\u003eThe \u003cstrong data-start=\"11975\" data-end=\"11988\"\u003eZE-15UB32\u003c\/strong\u003e uses \u003cstrong data-start=\"12015\" data-end=\"12041\"\u003e1\/4 inch liquid piping\u003c\/strong\u003e and \u003cstrong data-start=\"12045\" data-end=\"12067\"\u003e1\/2 inch gas piping\u003c\/strong\u003e. This information is especially important when a customer wants to replace an old heat pump while keeping the existing lines. You should never assume the old piping is compatible.\u003c\/p\u003e\n\u003cp data-start=\"12283\" data-end=\"12552\"\u003eThe allowed piping length is \u003cstrong data-start=\"12326\" data-end=\"12345\"\u003e10 to 98.4 feet\u003c\/strong\u003e, with a maximum elevation difference of \u003cstrong data-start=\"12382\" data-end=\"12394\"\u003e65 feet\u003c\/strong\u003e. The preload length is \u003cstrong data-start=\"12428\" data-end=\"12440\"\u003e25 feet\u003c\/strong\u003e. These limits must be respected to ensure proper operation and avoid performance issues.\u003c\/p\u003e\n\u003cp data-start=\"12554\" data-end=\"12924\"\u003eElectrically, this model operates at \u003cstrong data-start=\"12595\" data-end=\"12624\"\u003e208\/230 V, 60 Hz, single phase\u003c\/strong\u003e, with a \u003cstrong data-start=\"12634\" data-end=\"12649\"\u003eMCA of 14 A\u003c\/strong\u003e and a \u003cstrong data-start=\"12656\" data-end=\"12671\"\u003eMOP of 20 A\u003c\/strong\u003e. The required communication wire is a \u003cstrong data-start=\"12710\" data-end=\"12745\"\u003e4\/14 copper multi-strand 600 V\u003c\/strong\u003e. These elements must be checked before installation, especially in older homes in Montreal, Longueuil, or Laval, where the electrical panel may already be heavily loaded.\u003c\/p\u003e\n\u003ch2 data-start=\"12926\" data-end=\"12982\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"12929\" data-end=\"12982\"\u003e9. Maintenance and durability of the Zephyr ZE-15UB32\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"12984\" data-end=\"13311\"\u003eTo maintain good performance year after year, a wall-mounted heat pump must be properly maintained. Even an efficient unit like the \u003cstrong data-start=\"13133\" data-end=\"13153\"\u003eZephyr ZE-15UB32\u003c\/strong\u003e can lose efficiency if the filters are dirty, the drain is clogged, or the outdoor unit is blocked by leaves, snow, or debris.\u003c\/p\u003e\n\u003cp data-start=\"13313\" data-end=\"13342\"\u003eWe specifically recommend:\u003c\/p\u003e\n\u003cp data-start=\"13344\" data-end=\"13699\"\u003e• \u003cstrong data-start=\"13346\" data-end=\"13406\"\u003eRegularly clean the indoor unit filters\u003c\/strong\u003e\u003cbr data-start=\"13406\" data-end=\"13409\"\u003e• \u003cstrong data-start=\"13411\" data-end=\"13476\"\u003eCheck that the condensation drain is working properly\u003c\/strong\u003e\u003cbr data-start=\"13476\" data-end=\"13479\"\u003e• \u003cstrong data-start=\"13481\" data-end=\"13534\"\u003eKeep the outdoor unit clear in all seasons\u003c\/strong\u003e\u003cbr data-start=\"13534\" data-end=\"13537\"\u003e• \u003cstrong data-start=\"13539\" data-end=\"13576\"\u003eMonitor for unusual noises\u003c\/strong\u003e\u003cbr data-start=\"13576\" data-end=\"13579\"\u003e• \u003cstrong data-start=\"13581\" data-end=\"13637\"\u003eHave the unit inspected if performance decreases\u003c\/strong\u003e\u003cbr data-start=\"13637\" data-end=\"13640\"\u003e• \u003cstrong data-start=\"13642\" data-end=\"13699\"\u003eSchedule professional maintenance when necessary\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"13701\" data-end=\"14071\"\u003eThe brochure also highlights useful features such as \u003cstrong data-start=\"13757\" data-end=\"13782\"\u003eautomatic cleaning\u003c\/strong\u003e, \u003cstrong data-start=\"13787\" data-end=\"13812\"\u003eautomatic defrosting\u003c\/strong\u003e, \u003cstrong data-start=\"13817\" data-end=\"13853\"\u003ediffuser position memory\u003c\/strong\u003e, \u003cstrong data-start=\"13858\" data-end=\"13903\"\u003eheated chassis for the outdoor base\u003c\/strong\u003e, and \u003cstrong data-start=\"13910\" data-end=\"13938\"\u003ecompressor heating\u003c\/strong\u003e. These features improve daily use but do not replace careful installation or regular maintenance.\u003c\/p\u003e\n\u003ch2 data-start=\"14073\" data-end=\"14149\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"14076\" data-end=\"14149\"\u003e10. Why choose AirGreen to install this wall-mounted heat pump\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"14151\" data-end=\"14488\"\u003eAirGreen installs, maintains, and repairs HVAC systems in Greater Montreal, including Montreal, Laval, Longueuil, the South Shore, and the North Shore. Our local experience allows us to fully understand the realities of Quebec buildings: condos, single-family homes, multiplexes, businesses, offices, finished basements, and renovated spaces.\u003c\/p\u003e\n\u003cp data-start=\"14490\" data-end=\"14623\"\u003eBy choosing AirGreen to install a \u003cstrong data-start=\"14533\" data-end=\"14572\"\u003eZephyr ZE-15UB32 Wall-Mounted Heat Pump\u003c\/strong\u003e, customers benefit from a comprehensive approach:\u003c\/p\u003e\n\u003cp data-start=\"14625\" data-end=\"15084\"\u003e• \u003cstrong data-start=\"14627\" data-end=\"14676\"\u003eClear project evaluation before work begins\u003c\/strong\u003e\u003cbr data-start=\"14676\" data-end=\"14679\"\u003e• \u003cstrong data-start=\"14681\" data-end=\"14731\"\u003eVerification of capacity suited to the space\u003c\/strong\u003e\u003cbr data-start=\"14731\" data-end=\"14734\"\u003e• \u003cstrong data-start=\"14736\" data-end=\"14790\"\u003eValidation of indoor and outdoor location\u003c\/strong\u003e\u003cbr data-start=\"14790\" data-end=\"14793\"\u003e• \u003cstrong data-start=\"14795\" data-end=\"14860\"\u003eVerification of piping and electrical supply\u003c\/strong\u003e\u003cbr data-start=\"14860\" data-end=\"14863\"\u003e• \u003cstrong data-start=\"14865\" data-end=\"14916\"\u003eInstallation compliant with good HVAC practices\u003c\/strong\u003e\u003cbr data-start=\"14916\" data-end=\"14919\"\u003e• \u003cstrong data-start=\"14921\" data-end=\"14970\"\u003eHonest explanation of winter performance\u003c\/strong\u003e\u003cbr data-start=\"14970\" data-end=\"14973\"\u003e• \u003cstrong data-start=\"14975\" data-end=\"15008\"\u003eStructured after-sales service\u003c\/strong\u003e\u003cbr data-start=\"15008\" data-end=\"15011\"\u003e• \u003cstrong data-start=\"15013\" data-end=\"15084\"\u003eSupport to understand available warranties and options\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"15086\" data-end=\"15340\"\u003eA heat pump represents a significant investment. Our goal is for the client to fully understand what they are buying, why this model is recommended, and how the installation will be carried out to achieve a reliable, comfortable, and durable result.\u003c\/p\u003e\n\u003ch2 data-start=\"15342\" data-end=\"15387\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"15345\" data-end=\"15387\"\u003e11. Conclusion \u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp data-start=\"15389\" data-end=\"15919\"\u003eThe \u003cstrong data-start=\"15392\" data-end=\"15431\"\u003eZephyr ZE-15UB32 Wall-Mounted Heat Pump\u003c\/strong\u003e is a high-performance HVAC solution for homeowners who want a \u003cstrong data-start=\"15516\" data-end=\"15530\"\u003e15,000 BTU\u003c\/strong\u003e unit, efficient in cooling, strong in heating, and suited for Quebec winters. With its \u003cstrong data-start=\"15620\" data-end=\"15641\"\u003eR454B refrigerant\u003c\/strong\u003e, \u003cstrong data-start=\"15647\" data-end=\"15664\"\u003eSEER2 of 25.6\u003c\/strong\u003e, \u003cstrong data-start=\"15670\" data-end=\"15687\"\u003eHSPF2 of 11.1\u003c\/strong\u003e, operation down to \u003cstrong data-start=\"15716\" data-end=\"15726\"\u003e-30 °C\u003c\/strong\u003e, low outdoor noise level of \u003cstrong data-start=\"15766\" data-end=\"15778\"\u003e54 dB(A)\u003c\/strong\u003e, and many comfort features, it represents a very interesting choice for many residential and light commercial projects.\u003c\/p\u003e\n\u003cp data-start=\"15921\" data-end=\"16198\"\u003eHowever, its installation must be done seriously. The piping \u003cstrong data-start=\"15992\" data-end=\"16008\"\u003e1\/4 - 1\/2 inch\u003c\/strong\u003e, the power supply \u003cstrong data-start=\"16025\" data-end=\"16038\"\u003e208\/230 V\u003c\/strong\u003e, the \u003cstrong data-start=\"16043\" data-end=\"16058\"\u003e14 A MCA\u003c\/strong\u003e, the \u003cstrong data-start=\"16063\" data-end=\"16078\"\u003e20 A MOP\u003c\/strong\u003e, clearances, drainage, and the location of the indoor unit must be verified before confirming the project.\u003c\/p\u003e\n\u003cp data-start=\"16200\" data-end=\"16422\"\u003eFor a wall-mounted heat pump installation in Montreal, Laval, Longueuil, on the South Shore or the North Shore, AirGreen supports its clients with a professional, clear approach tailored to the real needs of the building.\u003c\/p\u003e","brand":"Zephyr","offers":[{"title":"Default Title","offer_id":55665927618852,"sku":"ZE-15UB32I","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPEZEPHYRUB32R454BGRANDMONTREAL_e1afd6ff-a1c2-43b1-876a-0d4d384f2963.png?v=1783695879"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/collections\/ZEPHYR_MINI_SPLIT_THERMOPOMPE_LOGO.png?v=1768464656","url":"https:\/\/airgreen.ca\/en\/collections\/thermopompes-murales-zephyr.oembed?page=2","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}