{"title":"Hydronic Fan Coils | Installation in Montreal, Laval, Longueuil, South Shore and North Shore","description":null,"products":[{"product_id":"ventilo-convecteur-hydronique-thermo-2000-ventum-40","title":"THERMO 2000 VenTum 40 Hydronic Fan Coil","description":"\u003ch2\u003eHot water in the loop, warm air in the ducts\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eThermo 2000 VenTum 40 hydronic fan coil\u003c\/strong\u003e links a hot-water heating system to a duct network. It takes hot water from a closed loop, circulates it through a 4-row copper coil and blows the heated air into the house, up to 1,100 CFM. The 1\/2 HP ECM fan, the built-in 3-speed circulator and the digital controller are housed in the same cabinet.\u003c\/p\u003e\n\u003ch3\u003eWho the VenTum 40 is for\u003c\/h3\u003e\n\u003cp\u003eIt suits homes that already have ductwork and that heat, or want to heat, with an electric boiler or an air-to-water heat pump. You keep forced-air distribution, but the heat comes from water. The front controller displays the unit’s status, temperatures and alarm codes. It manages 2 zones, offers separate airflow settings for heating, cooling, ventilation and dehumidification, a BOOST mode and an anti-freeze function that takes over if the house thermostat fails.\u003c\/p\u003e\n\u003ch3\u003eReading the capacity table for your source\u003c\/h3\u003e\n\u003cp\u003eThe heat delivered depends mainly on the water temperature. Thermo 2000 publishes a full table, with return air at 70 °F (21 °C). At 3 GPM and between 700 and 1,100 CFM, the VenTum 40 delivers 13,400 to 17,500 BTU\/h with 100 °F water, 24,400 to 31,900 BTU\/h at 120 °F and 47,400 to 63,200 BTU\/h at 160 °F. An air-to-water heat pump often works at the low end of this table, while an electric boiler can aim higher. That is why we size the unit with your source’s actual water temperature, not with the highest figure on the sheet.\u003c\/p\u003e\n\u003cp\u003eFor summer, an air conditioner or heat pump coil can be added as an option, with an outdoor unit. The manufacturer associates 2 tons of cooling with 700 and 800 CFM, and 3 tons with 900, 1,000 and 1,100 CFM.\u003c\/p\u003e\n\u003ch3\u003eIts place in a Quebec home\u003c\/h3\u003e\n\u003cp\u003eThe VenTum is multi-position: vertical in a basement in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, horizontal when height is limited in a townhouse in \u003cstrong\u003eMontreal\u003c\/strong\u003e. The return opening is pre-cut on the right, left or bottom, which simplifies the connection to existing ductwork. It weighs 99 lb, connects to the water through soldered 3\/4 in copper fittings and runs on 120 V single phase. The ductwork must stay within a maximum external static pressure of 0.75 in. w.c. The 16 x 20 x 1 in filter slides into the supplied rack.\u003c\/p\u003e\n\u003ch3\u003eWhat AirGreen’s installation includes\u003c\/h3\u003e\n\u003cp\u003eWe install the VenTum with electric boilers and air-to-water heat pumps, in \u003cstrong\u003eLaval\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and throughout Greater Montreal: free on-site estimate, written quote, setting the unit, connecting it to the water loop and the ductwork, placing the supplied air temperature sensors, adjusting the airflow and commissioning. The thermostat is not included; we choose it with you. Sold alone, the unit does not qualify for the LogisVert grant.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal for more than 15 years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). Thermo 2000 warrants all VenTum parts and components for 2 years, under its terms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTell us which source supplies your loop and at what temperature: we check whether the VenTum 40 is enough for the house. Free estimate and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801478594852,"sku":"VENTUM40","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/VENTILO_CONVECTEUR_HYDRONIQUE_THERMO_2000_VENTUM_40_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082279"},{"product_id":"ventilo-convecteur-hydronique-thermo-2000-ventum-60","title":"THERMO 2000 VenTum 60 Hydronic Fan Coil","description":"\u003ch2\u003eUp to 2,000 CFM of water-heated air, with optional cooling\u003c\/h2\u003e\n\u003cp\u003eIn a large house that already has ductwork, switching to hot-water heating does not mean giving up forced air. The \u003cstrong\u003eThermo 2000 VenTum 60 hydronic fan coil\u003c\/strong\u003e takes hot water from an electric boiler or an air-to-water heat pump and turns it into warm air, up to 2,000 CFM. It is the large size in the VenTum series: 3\/4 HP ECM fan, 10 x 10 in wheel, 4-row copper coil measuring 15 x 22 x 3.5 in and built-in 3-speed circulator.\u003c\/p\u003e\n\u003ch3\u003eThe large size in the VenTum series\u003c\/h3\u003e\n\u003cp\u003eThe VenTum 60 is meant for good-sized houses, multi-storey homes in \u003cstrong\u003eLaval\u003c\/strong\u003e or on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, and offices or small shops that already have ductwork. Its front digital controller manages 2 zones, displays status, temperatures and alarm codes, and allows a separate airflow for each mode: heating, cooling, ventilation, dehumidification. Airflow is set in 10 CFM steps, and a BOOST mode is available. An anti-freeze function takes over if the house thermostat fails.\u003c\/p\u003e\n\u003cp\u003eIn summer, an air conditioner or heat pump coil can be added as an option, with an outdoor unit. Thermo 2000 associates 3 tons of cooling with 1,200 CFM, 4 tons with 1,400 and 1,600 CFM, and 5 tons with 1,800 and 2,000 CFM.\u003c\/p\u003e\n\u003ch3\u003eChoosing the right operating point\u003c\/h3\u003e\n\u003cp\u003eThe heat delivered depends on the water temperature and its flow. The manufacturer publishes its capacities with return air at 70 °F (21 °C). With 120 °F water, the VenTum 60 delivers 35,900 to 47,400 BTU\/h at 3 GPM, and 40,000 to 56,000 BTU\/h at 5 GPM, between 1,200 and 2,000 CFM. With 140 °F water at 5 GPM, the range rises to 59,100 to 87,500 BTU\/h. The published pressure drop is 5 psi at 5 GPM. We therefore start from your source’s actual temperature to choose the water flow and the airflow, then check that the ductwork stays within the maximum external static pressure of 0.75 in. w.c.\u003c\/p\u003e\n\u003cp\u003eThe loop can hold water or a propylene glycol mix up to 50%, with water from 50 to 200 °F. The water connections are 3\/4 in copper, soldered.\u003c\/p\u003e\n\u003ch3\u003eInstallation and next steps\u003c\/h3\u003e\n\u003cp\u003eAirGreen installs the VenTum in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and throughout Greater Montreal, with electric boilers and air-to-water heat pumps. Our work includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe free on-site estimate and a written quote;\u003c\/li\u003e\n\u003cli\u003esetting the unit, vertical or horizontal depending on the space, with the pre-cut return on the side that works;\u003c\/li\u003e\n\u003cli\u003econnecting it to the water loop and the ductwork, and placing the supplied air temperature sensors;\u003c\/li\u003e\n\u003cli\u003esetting the airflow for each mode and commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe unit weighs 120 lb and runs on 120 V single phase. The thermostat is not included. Sold alone, the VenTum 60 does not qualify for the LogisVert grant. AirGreen is a family business established in Montreal for more than 15 years, holding RBQ licence 5645-9605-01 (ventilation, refrigeration and electrical). Thermo 2000 warrants all VenTum parts and components for 2 years, under its terms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSend us the area to serve, your heat source and your cooling plans: we confirm whether the VenTum 60 is the right size. Free estimate and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801489670436,"sku":"VENTUM60","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/VENTILO_CONVECTEUR_HYDRONIQUE_THERMO_2000_VENTUM_60_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082278"}],"url":"https:\/\/airgreen.ca\/en\/collections\/ventilo-convecteurs-hydroniques-installation-a-montreal-laval-longueuil-rive-sud-et-rive-nord.oembed","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}