{"product_id":"capteur-general-airstage-uty-xszxz1-montreal-laval-longueuil-rive-sud-rive-nord","title":"Sensor GENERAL AIRSTAGE UTY-XSZXZ1 | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003cp\u003eWhen a \u003cstrong\u003educted heat pump\u003c\/strong\u003e lives in the basement, a mechanical closet or the attic, it is the \u003cstrong\u003ereturn air\u003c\/strong\u003e it checks by default to judge the temperature. That is not necessarily the air of the room where you spend your evenings: near a basement floor, it tends to be cooler, and if it brushes past the unit, it can be warmer. Mounted on the wall of the room itself, the \u003cstrong\u003eGENERAL AIRSTAGE UTY-XSZXZ1 remote sensor\u003c\/strong\u003e corrects that gap by taking the temperature where it counts. Take off the GENERAL label and you have the Fujitsu AIRSTAGE UTY-XSZXZ1, which we also sell (\u003ca href=\"https:\/\/airgreen.ca\/products\/capteur-fujitsu-uty-xszxz1-montreal-laval-longueuil-rive-sud-rive-nord\"\u003ethe same part under the Fujitsu AIRSTAGE brand\u003c\/a\u003e). On January 1, 2026, Fujitsu General Limited officially took the name GENERAL Inc., following its acquisition by Paloma Rheem Holdings; nothing has changed regarding the manufacturer, the factories, the AIRSTAGE products or the model numbers. Since GENERAL will gradually replace the Fujitsu name, the part is sold for now under both labels, and AirGreen offers both as an authorized GENERAL and Fujitsu AIRSTAGE dealer.\u003c\/p\u003e\n\n\u003ch2\u003eThe temperature read where you live\u003c\/h2\u003e\n\u003cp\u003eIn practical terms, the UTY-XSZXZ1 connects in place of the ducted indoor unit's return air probe. From then on, it is the real temperature of the occupied space that guides the \u003cstrong\u003eheating and cooling\u003c\/strong\u003e: fewer premature shutdowns, fewer cycles that drag on, and steadier comfort. Nothing changes in your routine, though, since the sensor \u003cstrong\u003eretains the temperature adjustment\u003c\/strong\u003e: you set the setpoint as before.\u003c\/p\u003e\n\u003cp\u003eThree types of ducted \u003cstrong\u003eAIRSTAGE (GENERAL or Fujitsu)\u003c\/strong\u003e units accept it: \u003cstrong\u003eslim duct\u003c\/strong\u003e models, \u003cstrong\u003emedium static pressure\u003c\/strong\u003e models and \u003cstrong\u003emulti-position air handlers\u003c\/strong\u003e (AHU). No battery to keep an eye on and no power pack to install: the indoor unit powers it.\u003c\/p\u003e\n\n\u003ch3\u003eA cable long enough to change floors\u003c\/h3\u003e\n\u003cp\u003eIn the box, the sensor comes with \u003cstrong\u003e33 ft of control cable\u003c\/strong\u003e, about 10 m. That is enough to go up from the basement to a ground-floor wall, or down from a suspended ceiling to the wall of the main room. As for the housing, at \u003cstrong\u003e2-3\/16 x 2-3\/4 x 1-3\/16 in.\u003c\/strong\u003e, it is quickly forgotten.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eType\u003c\/strong\u003e: remote ambient temperature sensor, wall mount\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCompatible systems\u003c\/strong\u003e: ducted AIRSTAGE (GENERAL or Fujitsu) indoor units\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eApplicable models\u003c\/strong\u003e: slim ducts, medium static pressure ducts, multi-position air handlers (AHU)\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: replaces the return air probe for a more accurate room reading\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAdjustment\u003c\/strong\u003e: retains the temperature adjustment\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e: from the indoor unit\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e: wired\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIncluded\u003c\/strong\u003e: sensor with 33 ft control cable\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e: none\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 2-3\/16 x 2-3\/4 x 1-3\/16 in. (H x W x D)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhen we suggest it\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eThe unit is in the basement but heats the ground floor and the upper floor: the air coming back to it from below is often cooler than the air in the living areas.\u003c\/li\u003e\n\u003cli\u003eThe equipment is shut away in a mechanical closet or a suspended ceiling, and the air around it says nothing about the temperature of the house.\u003c\/li\u003e\n\u003cli\u003eIn a large open area, you want comfort measured at occupant height rather than next to a grille.\u003c\/li\u003e\n\u003cli\u003eIn a commercial space, the return air passes through a ceiling plenum.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eOne clarification is in order: with no screen and no buttons, the sensor does not act as a thermostat. To adjust your system, you keep using its controller or its remote.\u003c\/p\u003e\n\u003cp\u003eIt is mostly in winter that the gap makes itself felt: depending on the case, the ducted unit heats longer than it should, or the living areas stay a little cool. With a reading taken where you live, the \u003cstrong\u003eheat pump\u003c\/strong\u003e holds a steady setpoint, which pays off in comfort and savings over a long heating season. In summer, the logic is the same: no need to overcool a floor to make up for a reading taken close to the unit.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation, a matter of location\u003c\/h2\u003e\n\u003cp\u003eA badly placed sensor measures badly. Our technicians therefore aim for an interior wall, at occupant height, and keep the sensor away from anything that would skew the reading: supply grilles, windows, cooking appliances, direct sun. The 33 ft cable is then run to the unit, the sensor takes the place of the return air probe, and we watch how the system behaves, in heating mode as well as in cooling.\u003c\/p\u003e\n\n\u003ch3\u003eMaintenance\u003c\/h3\u003e\n\u003cp\u003eMaintenance-wise, this sensor is easy to forget about. Simply keep it uncovered, with no furniture or decoration in front of it, and away from any new heat source that might appear after installation. Planning to rearrange the room: let us know, and we will confirm its location again.\u003c\/p\u003e\n\n\u003ch3\u003eWhy AirGreen\u003c\/h3\u003e\n\u003cp\u003eOur Boucherville showroom, our RBQ licence and more than 15 years spent in air conditioning and heating: AirGreen Inc. is a family business, and its technicians install the manufacturer's ducted heat pumps, GENERAL as well as Fujitsu, adjusting each installation so that comfort is measured in the right place. The GENERAL AIRSTAGE UTY-XSZXZ1 remote sensor can be bought and installed through AirGreen, anywhere in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n","brand":"GENERAL","offers":[{"title":"Default Title","offer_id":67944739111204,"sku":"UTY-XSZXZ1","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_CAPTEUR_GENERAL_AIRSTAGE_UTY-XSZXZ1_CARTE_PRINCIPALE_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_0e299213-4062-4f00-af0f-abd2cd839143.png?v=1793182781","url":"https:\/\/airgreen.ca\/en\/products\/capteur-general-airstage-uty-xszxz1-montreal-laval-longueuil-rive-sud-rive-nord","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}