{"product_id":"cassette-de-plafond-1-voie-senville-sena-r454b-12000-btu","title":"1-Way Ceiling Cassette SENVILLE SENA R454B | 12000 BTU","description":"\u003ch2\u003eA linear cassette designed for rooms where air distribution should follow the architecture rather than occupy it\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSENVILLE SENA R454B 12,000 BTU 1-Way Ceiling Cassette\u003c\/strong\u003e offers a very different solution from a traditional wall-mounted heat pump. Here, the indoor unit does not occupy a wall above a window, sofa, or piece of furniture: it is integrated into the ceiling and distributes air primarily in one direction. This design can be particularly appealing for certain residential renovations, offices, businesses, wide corridors, rectangular rooms, and spaces where the interior layout leaves little available wall space.\u003c\/p\u003e\n\u003cp\u003eThe combination presented by AirGreen pairs the \u003cstrong\u003eSENA-12HF-OG\u003c\/strong\u003e outdoor unit with the \u003cstrong\u003eSENA-12HF-1WCG\u003c\/strong\u003e indoor unit, under \u003cstrong\u003eAHRI 216623594\u003c\/strong\u003e. Senville documentation identifies the family as \u003cstrong\u003eSENA-12HF-1WC\u003c\/strong\u003e and presents it as a 12,000 BTU 1-way ceiling cassette operating in both cooling and heating modes. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor our \u003cstrong\u003eHVAC projects in Montreal, Laval, Longueuil, on the South Shore and the North Shore\u003c\/strong\u003e, this type of unit becomes especially appealing when we want to keep the walls clear while achieving more structured air distribution. However, its selection requires thorough preparation: ceiling space, service access, piping, drainage, and the exact position of the air outlet must all be considered before work begins.\u003c\/p\u003e\n\u003ch3\u003eKey specifications of the SENVILLE 12,000 BTU 1-Way\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen information sheet for this combination indicates, among other things:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003ecooling capacity: 12,000 BTU\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSEER2: 23.0\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEER2: 13.0\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHSPF2: 10.0\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003erefrigerant: R-454B\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eENERGY STAR: yes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCold Climate: yes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eheating down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eWiFi available \u003cstrong\u003eas an option\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003epower supply \u003cstrong\u003e220 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003epiping \u003cstrong\u003e1\/4 in. – 3\/8 in.\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMCA: 15 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMOP: 15 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eadvertised provincial rebate: \u003cstrong\u003e1 152 $\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSenville’s technical table confirms that the 12,000 BTU model has a \u003cstrong\u003eSEER2 of 23.0\u003c\/strong\u003e, an \u003cstrong\u003eEER2 of 13\u003c\/strong\u003e, a \u003cstrong\u003eRegion 4 HSPF2 of 10.0\u003c\/strong\u003e, a rated heating capacity of \u003cstrong\u003e12,500 BTU\/h\u003c\/strong\u003e, and a rated COP of \u003cstrong\u003e3.56\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhy the 1-way design truly changes how the installation is planned\u003c\/h3\u003e\n\u003cp\u003eThe cassette measures approximately \u003cstrong\u003e50.31 in. wide × 13.19 in. deep × 8.98 in. high\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis long, narrow geometry immediately distinguishes it from a conventional square cassette.\u003c\/p\u003e\n\u003cp\u003eA four-way cassette is often positioned closer to the center of a room to distribute air in several directions. A 1-way cassette is better suited to configurations where air needs to be directed along a primary axis—for example, along a long room, from a peripheral area, or in a narrower space.\u003c\/p\u003e\n\u003cp\u003eIn a well-designed project, this feature can be an advantage. In a poorly planned project, it can become a limitation.\u003c\/p\u003e\n\u003cp\u003eWe therefore want the air directed \u003cstrong\u003etoward the area being conditioned\u003c\/strong\u003e, rather than toward a wall located a few feet from the cassette.\u003c\/p\u003e\n\u003ch3\u003eAn example of a configuration where this cassette makes a great deal of sense\u003c\/h3\u003e\n\u003cp\u003eLet’s consider a large rectangular room in a condo in \u003cstrong\u003eMontreal\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eOne side of the room is occupied by a bay window. The other side contains cabinets and decorative elements. Installing a visible wall-mounted head becomes difficult without compromising the layout.\u003c\/p\u003e\n\u003cp\u003eA 1-way cassette installed in the ceiling can free up these surfaces while directing air along the length of the room.\u003c\/p\u003e\n\u003cp\u003eThis is precisely the type of situation in which we prefer to consider the building’s geometry before its simple rated capacity.\u003c\/p\u003e\n\u003ch3\u003e12,000 BTU does not automatically mean that it is suitable for every room requiring 12,000 BTU\u003c\/h3\u003e\n\u003cp\u003eSenville’s documentation recommends this product family for spaces of approximately \u003cstrong\u003e400 to 600 sq. ft.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis figure should be used as a reference, not as a sizing formula.\u003c\/p\u003e\n\u003cp\u003eA 500 sq. ft. living room on the top floor with large southwest-facing windows may have a much higher heating and cooling load than an office of the same size on the ground floor.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, we take the following factors into account:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003einsulation;\u003c\/li\u003e\n\u003cli\u003ewindows;\u003c\/li\u003e\n\u003cli\u003esolar exposure;\u003c\/li\u003e\n\u003cli\u003ethe ceiling height;\u003c\/li\u003e\n\u003cli\u003ethe floor;\u003c\/li\u003e\n\u003cli\u003ethe room layout;\u003c\/li\u003e\n\u003cli\u003ethe number of occupants;\u003c\/li\u003e\n\u003cli\u003eequipment that produces heat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSEER2 of 23: solid seasonal efficiency\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSEER2 of 23\u003c\/strong\u003e is one of the key technical features of this 1-way cassette.\u003c\/p\u003e\n\u003cp\u003eThe series’ general documentation also highlights its high efficiency and ENERGY STAR certification. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor the homeowner, this mainly means that the system belongs to a category in which seasonal cooling consumption is optimized by inverter technology.\u003c\/p\u003e\n\u003cp\u003eHowever, SEER2 figures alone should not be compared between completely different system designs. A ceiling cassette is not chosen solely for its energy efficiency. Its integration into the room, placement, and air distribution are also decisive.\u003c\/p\u003e\n\u003ch3\u003eHeating down to -30 °C: actual capacities matter more than the minimum limit\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen specification sheet lists the following capacities:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eapproximately \u003cstrong\u003e9,600 BTU\/h at -8 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eapproximately \u003cstrong\u003e11,500 BTU\/h at -15 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eapproximately \u003cstrong\u003e5,100 BTU\/h at -30 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe stated COP is approximately:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e2.65 at -8 °C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e1.09 at -30 °C\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe brochure confirms that the series is designed to operate in heating mode down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis is an essential nuance.\u003c\/p\u003e\n\u003cp\u003eA heat pump can continue operating at -30 °C without retaining its full rated capacity.\u003c\/p\u003e\n\u003cp\u003eAt this extreme temperature, the building’s demand increases while the heat pump’s available capacity decreases. For a home in \u003cstrong\u003eLaval, Longueuil, or on the North Shore\u003c\/strong\u003e, a supplementary heating source may therefore still be necessary on the coldest days.\u003c\/p\u003e\n\u003ch3\u003eA relevant Cold Climate certification for Quebec\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen specification sheet identifies this combination as \u003cstrong\u003eCold Climate: yes\u003c\/strong\u003e, and Senville also presents the series as a heat pump intended for low-temperature heating. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis distinguishes the model from an air conditioner with only an occasional heating function.\u003c\/p\u003e\n\u003cp\u003eFor a homeowner looking to reduce the use of electric baseboard heaters during much of the winter, this distinction may be particularly valuable.\u003c\/p\u003e\n\u003ch3\u003eLow-ambient-temperature air conditioning may also be of interest to certain businesses\u003c\/h3\u003e\n\u003cp\u003eThe brochure mentions a \u003cstrong\u003elow-ambient-temperature air conditioning function down to -30 °C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIn a residence, this feature is rarely a priority.\u003c\/p\u003e\n\u003cp\u003eIn some commercial or technical spaces, however, a room may need cooling even when the outdoor temperature is low because of:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eequipment;\u003c\/li\u003e\n\u003cli\u003eservers;\u003c\/li\u003e\n\u003cli\u003elighting;\u003c\/li\u003e\n\u003cli\u003ehigh occupancy;\u003c\/li\u003e\n\u003cli\u003einternal heat gains.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis feature can therefore offer real value depending on the application.\u003c\/p\u003e\n\u003ch3\u003eInverter technology: the system does not operate at full capacity constantly\u003c\/h3\u003e\n\u003cp\u003eThe brochure clearly identifies \u003cstrong\u003einverter technology\u003c\/strong\u003e among the main features. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eInstead of constantly switching between off and full power, the compressor can modulate its operation according to demand.\u003c\/p\u003e\n\u003cp\u003eIn a medium-sized space, this may promote:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emore stable temperature;\u003c\/li\u003e\n\u003cli\u003equieter operation;\u003c\/li\u003e\n\u003cli\u003elonger cycles;\u003c\/li\u003e\n\u003cli\u003eenergy consumption better matched to the actual load.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFollow Me function: the temperature can be measured closer to the occupant\u003c\/h3\u003e\n\u003cp\u003eThe documentation mentions a remote control with the \u003cstrong\u003eFollow Me\u003c\/strong\u003e function. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis feature may be useful with a ceiling cassette.\u003c\/p\u003e\n\u003cp\u003eThe temperature near the ceiling may differ from the temperature felt at the level where occupants are located. By using a sensor built into the remote control as intended by the manufacturer, the system can take a measurement that more accurately represents the occupied zone.\u003c\/p\u003e\n\u003ch3\u003eSelf-diagnostics, leak detection, and self-cleaning mode\u003c\/h3\u003e\n\u003cp\u003eSenville mentions several functions intended to simplify operation and maintenance:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003erefrigerant leak detection;\u003c\/li\u003e\n\u003cli\u003ediagnostic display;\u003c\/li\u003e\n\u003cli\u003eself-cleaning mode;\u003c\/li\u003e\n\u003cli\u003eself-diagnostic system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThese functions can help identify certain problems more quickly.\u003c\/p\u003e\n\u003cp\u003eHowever, they do not replace \u003cstrong\u003eprofessional HVAC maintenance\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eA system may lose performance because of a filter, drain, sensor, refrigerant charge issue, or electronic component. A diagnostic code is an indication, not always the complete diagnosis.\u003c\/p\u003e\n\u003ch2\u003eA one-way cassette requires more careful planning than a wall-mounted unit\u003c\/h2\u003e\n\u003ch3\u003eThe ceiling must provide sufficient technical space\u003c\/h3\u003e\n\u003cp\u003eThe unit is approximately \u003cstrong\u003e8.98 inches high\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis does not mean that a nine-inch ceiling cavity is automatically sufficient.\u003c\/p\u003e\n\u003cp\u003eWe must also plan for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe refrigerant connections;\u003c\/li\u003e\n\u003cli\u003ethe drain;\u003c\/li\u003e\n\u003cli\u003ethe cables;\u003c\/li\u003e\n\u003cli\u003eclearances;\u003c\/li\u003e\n\u003cli\u003ethe support;\u003c\/li\u003e\n\u003cli\u003efuture access.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn a \u003cstrong\u003eMontreal\u003c\/strong\u003e renovation, the visually ideal location may have a joist, beam, or duct above the ceiling.\u003c\/p\u003e\n\u003cp\u003eThe best installation is therefore determined after inspecting what is actually located in the cavity.\u003c\/p\u003e\n\u003ch3\u003eThe 50-inch length must be planned before opening the ceiling\u003c\/h3\u003e\n\u003cp\u003eAn indoor unit \u003cstrong\u003e50.31 inches long\u003c\/strong\u003e requires a sufficiently clear, continuous area.\u003c\/p\u003e\n\u003cp\u003eIt is much longer than a compact square cassette.\u003c\/p\u003e\n\u003cp\u003eBefore cutting anything, we check:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ejoist locations;\u003c\/li\u003e\n\u003cli\u003eplumbing;\u003c\/li\u003e\n\u003cli\u003ecables;\u003c\/li\u003e\n\u003cli\u003eexisting ducts;\u003c\/li\u003e\n\u003cli\u003elight fixtures;\u003c\/li\u003e\n\u003cli\u003esprinklers;\u003c\/li\u003e\n\u003cli\u003eceiling structure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMoving it a few inches at the beginning of the project can prevent many modifications after the opening is made.\u003c\/p\u003e\n\u003ch3\u003eDrainage is one of the most important elements\u003c\/h3\u003e\n\u003cp\u003eA cassette is installed above the occupied space.\u003c\/p\u003e\n\u003cp\u003eAn improperly controlled condensate leak can therefore damage:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eceiling;\u003c\/li\u003e\n\u003cli\u003epaint;\u003c\/li\u003e\n\u003cli\u003efurniture;\u003c\/li\u003e\n\u003cli\u003efinishes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThat is why the drain route must be designed before the finishing is closed up.\u003c\/p\u003e\n\u003cp\u003eWhenever possible, we favor a simple, accessible route and avoid paths that unnecessarily complicate maintenance.\u003c\/p\u003e\n\u003ch3\u003eR-454B precharged for 25 feet\u003c\/h3\u003e\n\u003cp\u003eSenville documentation states that the system is precharged with \u003cstrong\u003eR-454B for a length of up to 25 feet\u003c\/strong\u003e. An installation using 50 feet of piping requires the installer to add refrigerant. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe piping specified for the 12,000 BTU model is:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e1\/4 in. liquid\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e3\/8 in. gas\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eSince R-454B is an A2L refrigerant, commissioning must be carried out using appropriate methods and equipment.\u003c\/p\u003e\n\u003ch3\u003eWhy evacuation remains essential\u003c\/h3\u003e\n\u003cp\u003eThe factory charge is contained in the outdoor unit.\u003c\/p\u003e\n\u003cp\u003eThe piping installed on site initially contains air and moisture.\u003c\/p\u003e\n\u003cp\u003eA proper installation therefore requires, among other things:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003econnection inspection;\u003c\/li\u003e\n\u003cli\u003eleak test;\u003c\/li\u003e\n\u003cli\u003eevacuation;\u003c\/li\u003e\n\u003cli\u003ecommissioning;\u003c\/li\u003e\n\u003cli\u003eoperation check.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eImproper circuit preparation can reduce performance and adversely affect the system's service life.\u003c\/p\u003e\n\u003ch3\u003e208\/230 V power supply\u003c\/h3\u003e\n\u003cp\u003eThe technical table indicates a \u003cstrong\u003e208\/230 V, 60 Hz, single-phase\u003c\/strong\u003e power supply. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe AirGreen product sheet specifies:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eMCA: 15 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMOP: 15 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese values remain relatively modest for a 12,000 BTU system, but the circuit must obviously be prepared in accordance with the nameplate data and the site's electrical requirements.\u003c\/p\u003e\n\u003ch3\u003eCompact outdoor unit to facilitate urban installations\u003c\/h3\u003e\n\u003cp\u003eThe outdoor unit measures approximately \u003cstrong\u003e31.69 × 12.99 × 21.81 in\u003c\/strong\u003e according to the 12,000 BTU model table. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis size can facilitate certain installations in side yards or on properties where available space is limited.\u003c\/p\u003e\n\u003cp\u003eWe must nevertheless comply with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eclearances;\u003c\/li\u003e\n\u003cli\u003esnow;\u003c\/li\u003e\n\u003cli\u003ewater drainage;\u003c\/li\u003e\n\u003cli\u003ethe neighbors;\u003c\/li\u003e\n\u003cli\u003emunicipal regulations;\u003c\/li\u003e\n\u003cli\u003efuture access.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOptional WiFi\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen product sheet indicates that \u003cstrong\u003eWiFi is available as an option\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIn a residence, this can simplify scheduling.\u003c\/p\u003e\n\u003cp\u003eIn an office or small business, remote control can be even more useful by allowing the temperature to be managed according to occupancy hours.\u003c\/p\u003e\n\u003ch3\u003eWhy choose a 1-way cassette instead of a square cassette\u003c\/h3\u003e\n\u003cp\u003eThe two products are not intended for exactly the same configurations.\u003c\/p\u003e\n\u003cp\u003eA conventional square cassette may be preferable when it is installed in the center of a room and you want to distribute air around it.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003e1-way cassette\u003c\/strong\u003e makes more sense when you want to direct airflow in a primary direction and take advantage of its linear format.\u003c\/p\u003e\n\u003cp\u003eA good example would be a long room, a room located along a glass façade, or a space where integrating a central square cassette would be difficult.\u003c\/p\u003e\n\u003ch3\u003ePoor orientation can cancel out the advantage of the 1-way format\u003c\/h3\u003e\n\u003cp\u003eThe name “1-way” should be taken seriously.\u003c\/p\u003e\n\u003cp\u003eIf the unit is positioned so that it sends its air directly toward a nearby wall, part of its potential range will be lost.\u003c\/p\u003e\n\u003cp\u003eThe AirGreen product sheet indicates:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003evertical louver: \u003cstrong\u003eautomatic\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003ehorizontal louver: \u003cstrong\u003emanual\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis allows for certain adjustments, but the initial positioning remains crucial.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, we therefore analyze the airflow direction before deciding precisely where to open the ceiling.\u003c\/p\u003e\n\u003ch3\u003eDisplayed provincial rebate: $1,152\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen product sheet indicates a \u003cstrong\u003e$1,152 provincial rebate\u003c\/strong\u003e for this combination.\u003c\/p\u003e\n\u003cp\u003eIt also displays:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eENERGY STAR: yes\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eCold Climate: yes\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eENERGY STAR ID: 3893584\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eAHRI: 216623594\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSenville documentation confirms the series' ENERGY STAR certification. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHowever, all financial incentives must be validated at the time of quoting according to the rules of the program in effect and the exact installed configuration.\u003c\/p\u003e\n\u003ch3\u003eWarranty: a difference between the AirGreen product page and Senville documentation\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen product page lists a manufacturer's warranty:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e10-year compressor – 10-year parts – 0-year labour\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe Senville brochure instead states:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e10 years on the compressor and 5 years on parts\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIt is therefore important to confirm the exact coverage applicable to the product sold by AirGreen, including any registration requirements.\u003c\/p\u003e\n\u003ch3\u003eWhich projects is this SENVILLE cassette particularly well suited for?\u003c\/h3\u003e\n\u003cp\u003eWe consider it particularly suitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea living room or living area where the walls need to remain clear;\u003c\/li\u003e\n\u003cli\u003ean office;\u003c\/li\u003e\n\u003cli\u003ea commercial space;\u003c\/li\u003e\n\u003cli\u003ea rectangular room;\u003c\/li\u003e\n\u003cli\u003ea renovation with a suspended ceiling;\u003c\/li\u003e\n\u003cli\u003ea room with large windows;\u003c\/li\u003e\n\u003cli\u003ean installation where directional airflow is advantageous.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is less suitable when the ceiling provides no access or when the structure requires too many modifications.\u003c\/p\u003e\n\u003ch3\u003eWhat we check at AirGreen before confirming the installation\u003c\/h3\u003e\n\u003cp\u003eFor a \u003cstrong\u003eceiling cassette installation in Montreal, Laval, Longueuil, on the South Shore, or on the North Shore\u003c\/strong\u003e, we assess in particular:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003ethe room's heating and cooling load;\u003c\/li\u003e\n\u003cli\u003eavailable space in the ceiling;\u003c\/li\u003e\n\u003cli\u003ejoist positioning;\u003c\/li\u003e\n\u003cli\u003eairflow direction;\u003c\/li\u003e\n\u003cli\u003edrainage;\u003c\/li\u003e\n\u003cli\u003epiping length;\u003c\/li\u003e\n\u003cli\u003eelectrical supply;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit location;\u003c\/li\u003e\n\u003cli\u003efuture access;\u003c\/li\u003e\n\u003cli\u003eapplicable financial incentives.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThis preparation is particularly important for a cassette because several components become invisible once the ceiling is closed.\u003c\/p\u003e\n\u003ch3\u003eOur assessment of the SENVILLE SENA 12,000 BTU 1-way cassette\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSENA-12HF-1WC \/ SENA-12HF-1WCG\u003c\/strong\u003e offers an interesting combination for a discreet, directional installation:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e12,000 BTU in cooling\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e12,500 BTU nominal heating capacity according to the brochure\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSEER2 of 23\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEER2 of 13\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHSPF2-4 of 10\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eheating down to \u003cstrong\u003e-30 °C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eENERGY STAR\u003c\/li\u003e\n\u003cli\u003eCold Climate\u003c\/li\u003e\n\u003cli\u003eR-454B\u003c\/li\u003e\n\u003cli\u003eself-cleaning function\u003c\/li\u003e\n\u003cli\u003eleak detection\u003c\/li\u003e\n\u003cli\u003eself-diagnostics\u003c\/li\u003e\n\u003cli\u003eFollow Me function\u003c\/li\u003e\n\u003cli\u003elow-temperature cooling\u003c\/li\u003e\n\u003cli\u003ean indoor unit format of only \u003cstrong\u003e8.98 in. in height\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe value of this cassette therefore does not rest solely on its performance figures. It lies primarily in its ability to fit into a ceiling and condition the space without occupying a wall.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor a quote on a SENVILLE SENA 12,000 BTU 1-way ceiling cassette, contact AirGreen. We can assess the ceiling structure, required capacity, drainage, airflow direction, and applicable financial incentives for your project in Montreal, Laval, Longueuil, on the North Shore, or on the South Shore.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Senville","offers":[{"title":"Default Title","offer_id":56120175755556,"sku":"SENA-12HF-OG","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_CASSETTE_DE_PLAFOND_1_VOIE_SENVILLE_AURA_R454B_12000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1789060417","url":"https:\/\/airgreen.ca\/en\/products\/cassette-de-plafond-1-voie-senville-sena-r454b-12000-btu","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}