{"product_id":"chauffe-eau-indirect-thermo-2000-turbomax120-9-119-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"THERMO 2000 TURBOMAX120-9 Indirect Water Heater (119 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eA 119 US gallon indirect water heater to centralize hot water in an apartment building\u003c\/h2\u003e\n\u003cp\u003eIn many buildings in the region, each apartment still has its own electric water heater, often hidden in a closet. When the building is heated by a central \u003cstrong\u003eelectric boiler\u003c\/strong\u003e, it becomes possible to produce all the hot water in one place. The \u003cstrong\u003eThermo 2000 TurboMax 120-9 indirect water heater\u003c\/strong\u003e is designed for this role: a \u003cstrong\u003e119 US gallon\u003c\/strong\u003e tank, a \u003cstrong\u003e58.9 sq. ft. copper coil system\u003c\/strong\u003e and a maximum domestic hot water flow of \u003cstrong\u003e27 gpm\u003c\/strong\u003e. AirGreen installs it in buildings in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eCentralize rather than multiply water heaters\u003c\/h3\u003e\n\u003cp\u003eA dozen individual water heaters means as many units to replace one day, as many leak risks inside the apartments and as many visits to tenants. Centralized production groups everything in the mechanical room: a single tank to maintain, accessible without disturbing anyone, and an electric boiler serving both heating and hot water. For the owner, management becomes simpler; for tenants, repairs no longer take place in their unit. Before proposing this change, we review with you the cost allocation and the requirements that apply to distribution between units.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 119 US gallons\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e high-exchange-capacity copper coils, surface of 58.9 sq. ft.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDomestic hot water at 110 °F:\u003c\/strong\u003e maximum exchange capacity of 1,165,000 BTU\/h (341 kW); 2,122 US GPH first hour; 2,002 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDomestic hot water at 140 °F:\u003c\/strong\u003e maximum exchange capacity of 820,000 BTU\/h (240 kW); 1,038 US GPH first hour; 990 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDomestic hot water at 160 °F:\u003c\/strong\u003e maximum exchange capacity of 545,000 BTU\/h (160 kW); 569 US GPH first hour; 549 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConditions:\u003c\/strong\u003e domestic cold water at 40 °F, boiler water at 180 °F\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum domestic hot water flow:\u003c\/strong\u003e 27 gpm\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum pressure:\u003c\/strong\u003e 150 psi\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e potable water 2 in male sweat; boiler 2 in NPT male\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e height 76 3\/4 in, diameter 28 in\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 430 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCommercial-level exchange capacities\u003c\/h3\u003e\n\u003cp\u003eThe TurboMax copper coil system heats water instantly, according to Thermo 2000, and its exchanger can transfer up to 1,165,000 BTU\/h (341 kW) for water at 110 °F. These figures show the exchanger’s maximum capacity, not the guaranteed output of your installation. With an electric boiler, it is the boiler’s capacity, and therefore the building’s electrical service, that sets the real continuous output. With an electric boiler, the exchanger is rarely the limiting factor; the real question is how much electrical capacity the building can devote to hot water. We do this calculation with you based on the existing or planned boiler.\u003c\/p\u003e\n\n\u003ch3\u003eFlow and distribution in the building\u003c\/h3\u003e\n\u003cp\u003eThe 27 gpm maximum domestic hot water flow can supply many units at the same time. Thermo 2000 specifies that these values must be reduced for high-temperature and continuous-flow applications. In a building, hot water travels several floors: we usually plan a \u003cstrong\u003erecirculation loop\u003c\/strong\u003e so it reaches distant units quickly, and a \u003cstrong\u003ethermostatic mixing valve\u003c\/strong\u003e at the tank outlet to deliver a safe temperature. The 2 in connections, on both the potable water and boiler sides, fit commercial-diameter distribution piping.\u003c\/p\u003e\n\n\u003ch3\u003eProduction at 140 °F and 160 °F\u003c\/h3\u003e\n\u003cp\u003eThe choice of production temperature directly affects the quantity of water available. According to the manufacturer’s table, the exchanger can transfer up to 820,000 BTU\/h (240 kW) for water at 140 °F, with 1,038 US GPH in the first hour and 990 US GPH continuous, and up to 545,000 BTU\/h (160 kW) for water at 160 °F, with 569 US GPH and 549 US GPH. The hotter the water produced, the lower the hourly output. In a residential building, we therefore choose the temperature according to real uses, and a mixing valve ensures a safe temperature for the units; in a mixed-use building with a business on the ground floor, hotter production meets more demanding uses.\u003c\/p\u003e\n\n\u003ch3\u003eDelivering and placing a 430 lb tank\u003c\/h3\u003e\n\u003cp\u003eThe TurboMax 120-9 weighs 430 lb empty and is 76 3\/4 in high and 28 in in diameter. In an existing building, the mechanical room is often in the basement, at the end of a narrow staircase. We plan the route, door widths, free height under the pipes and the floor capacity once the tank is filled. A nearby drain and service space around the fittings and drain valve are planned from the design stage.\u003c\/p\u003e\n\n\u003ch3\u003eContinuity of service\u003c\/h3\u003e\n\u003cp\u003eWhen all of a building’s hot water depends on a single tank, maintenance must be planned. Well-placed isolation valves allow work on the boiler, circulator or mixing valve while limiting the length of the outage. We recommend a yearly visit, announced to tenants in advance, which includes a test of the relief valve, a check of the controls and a partial draining through the tank drain valve.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s warranty\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 offers a \u003cstrong\u003e10-year commercial warranty\u003c\/strong\u003e and a \u003cstrong\u003e15-year residential warranty\u003c\/strong\u003e, as well as a \u003cstrong\u003e2-year warranty on mechanical components\u003c\/strong\u003e. The category that applies to your building is confirmed in writing with the quote.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation of the Thermo 2000 TurboMax 120-9 by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work. For centralizing a building’s hot water, our work includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea survey of the units, appliances and electric boiler capacity;\u003c\/li\u003e\n\u003cli\u003eassessment of the mechanical room, floor, drain and delivery route;\u003c\/li\u003e\n\u003cli\u003eremoval and disposal of the old individual water heaters, where applicable;\u003c\/li\u003e\n\u003cli\u003econnecting the potable water in 2 in, with thermostatic mixing valve and recirculation loop;\u003c\/li\u003e\n\u003cli\u003econnecting to the boiler in 2 in, with circulator, isolation valves and air vents;\u003c\/li\u003e\n\u003cli\u003ethe relief valve, its discharge pipe and the expansion tank;\u003c\/li\u003e\n\u003cli\u003ewiring the controls, commissioning and a yearly maintenance plan.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe work with building owners and property managers in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, Côte-des-Neiges, Notre-Dame-de-Grâce, Saint-Léonard, Brossard, Chomedey and across the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. The on-site estimate is free, the quote is written and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free quote for the Thermo 2000 TurboMax 120-9.\u003c\/strong\u003e Tell us the number of units and the boiler in place: we will present a clear, step-by-step centralization project.\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801428853028,"sku":"TURBOMAX120-9","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_THERMO_2000_TURBOMAX120_9_119_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082279","url":"https:\/\/airgreen.ca\/en\/products\/chauffe-eau-indirect-thermo-2000-turbomax120-9-119-gallons-montreal-laval-longueuil-rive-sud-rive-nord","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}