{"product_id":"chauffe-eau-indirect-thermo-2000-turbomax120-9a-200-120-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"THERMO 2000 TURBOMAX120-9A 200 Indirect Water Heater (120 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eA 120 US gallon indirect water heater designed for a 200 psi maximum pressure\u003c\/h2\u003e\n\u003cp\u003eIn a residential tower, an institutional building or an industrial site, water often circulates at a higher pressure than in a house, pushed by a booster pump to reach the upper floors or supply demanding equipment. The \u003cstrong\u003eThermo 2000 TurboMax 120-9A 200 indirect water heater\u003c\/strong\u003e is made for these networks: its maximum pressure reaches \u003cstrong\u003e200 psi\u003c\/strong\u003e. It combines a \u003cstrong\u003e120 US gallon\u003c\/strong\u003e tank, a \u003cstrong\u003e58.9 sq. ft. copper coil system\u003c\/strong\u003e and 2 1\/2 in potable water connections, with an \u003cstrong\u003eelectric boiler\u003c\/strong\u003e as the heat source. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhy maximum pressure matters in large buildings\u003c\/h3\u003e\n\u003cp\u003eEvery unit connected to a building’s water network must withstand the pressure in it, including during peaks and water hammer. In a tall building, pressure is higher on the lower floors, where the mechanical room is usually located. A tank with a 200 psi maximum pressure offers a comfortable margin under these conditions. It also allows hot water production to be installed on the high-pressure side of the network when the design requires it, rather than multiplying pressure-reducing valves.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 120 US gallons\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum pressure:\u003c\/strong\u003e 200 psi\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e high-exchange-capacity copper coils, surface of 58.9 sq. ft.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWater at 110 °F:\u003c\/strong\u003e maximum exchange capacity of 1,165,000 BTU\/h (341 kW); 2,122 US GPH first hour; 2,002 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWater at 140 °F:\u003c\/strong\u003e maximum exchange capacity of 820,000 BTU\/h (240 kW); 1,038 US GPH first hour; 990 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWater at 160 °F:\u003c\/strong\u003e maximum exchange capacity of 545,000 BTU\/h (160 kW); 569 US GPH first hour; 549 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConditions:\u003c\/strong\u003e domestic cold water at 40 °F, boiler water at 180 °F\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum domestic hot water flow:\u003c\/strong\u003e 27 gpm\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e potable water 2 1\/2 in male sweat; boiler 2 in NPT male\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e height 76 3\/4 in, diameter 28 in\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 540 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eResidential towers, institutions and industrial buildings\u003c\/h3\u003e\n\u003cp\u003eThis model is aimed at buildings where both pressure and demand are high. A residential tower whose mechanical room is in the basement, a healthcare or education facility whose network is kept under pressure by a booster pump, an industrial building where hot water supplies washing stations. In each of these cases, the 120 US gallon reserve absorbs the peaks and the exchanger keeps production going as long as the electric boiler supplies the necessary heat. The 27 gpm maximum flow and the 2 1\/2 in connections suit large-diameter distribution.\u003c\/p\u003e\n\n\u003ch3\u003eA pressure margin does not replace safety devices\u003c\/h3\u003e\n\u003cp\u003eA high maximum pressure does not remove the need for safety devices. The relief valve is chosen according to the tank’s maximum pressure and capacity, an expansion tank absorbs the expansion of the heated water, and a pressure-reducing valve remains useful when supply pressure exceeds what the other components of the installation accept. We measure the real pressure, including while the booster pump is running, before finalizing the design.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the 58.9 sq. ft. exchanger can deliver\u003c\/h3\u003e\n\u003cp\u003eAccording to Thermo 2000, the high-exchange-capacity copper coil system heats water instantly. Its exchanger can transfer up to 1,165,000 BTU\/h (341 kW) for water at 110 °F, which gives 2,122 US GPH in the first hour and 2,002 US GPH continuous at full capacity. These values assume the boiler supplies that output, which is not the case for every electric boiler; the real continuous output follows the boiler’s capacity and therefore the building’s electrical service. The manufacturer adds that the values must be reduced for high-temperature and continuous-flow applications. Our quote states the expected output with your boiler.\u003c\/p\u003e\n\n\u003ch3\u003eA 540 lb tank to plan for\u003c\/h3\u003e\n\u003cp\u003eThe TurboMax 120-9A 200 weighs 540 lb empty and is 76 3\/4 in high and 28 in in diameter. In a tower, delivery sometimes goes through a freight elevator or a service entrance; in an industrial building, through a garage door. We plan the route, the handling equipment, the floor capacity once the tank is filled, access to a drain and the service space around the fittings and drain valve.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s warranty\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 offers a \u003cstrong\u003e10-year commercial warranty\u003c\/strong\u003e, a \u003cstrong\u003e15-year residential warranty\u003c\/strong\u003e and a \u003cstrong\u003e2-year warranty on mechanical components\u003c\/strong\u003e. The category applicable to your building is confirmed in writing with the quote.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation of the Thermo 2000 TurboMax 120-9A 200 by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal and active in heating, ventilation and air conditioning for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work. For this high-pressure indirect water heater, our work includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the supply pressure, including while the booster pump is running;\u003c\/li\u003e\n\u003cli\u003eanalysis of hot water needs and of the electric boiler’s capacity;\u003c\/li\u003e\n\u003cli\u003eplanning of delivery, handling and positioning;\u003c\/li\u003e\n\u003cli\u003econnecting the potable water in 2 1\/2 in, with thermostatic mixing valve and isolation valves;\u003c\/li\u003e\n\u003cli\u003econnecting to the boiler in 2 in, with circulator, check valve and air vents;\u003c\/li\u003e\n\u003cli\u003ethe relief valve, its discharge pipe, the expansion tank and, if needed, the pressure-reducing valve;\u003c\/li\u003e\n\u003cli\u003ewiring the controls, commissioning and a yearly maintenance plan.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe work with property managers, institutions and companies in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, downtown, Nuns’ Island, Saint-Laurent, Boucherville, Terrebonne and across the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. The on-site estimate is free, the quote is written and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free quote for the Thermo 2000 TurboMax 120-9A 200.\u003c\/strong\u003e Send us your network pressure and your boiler’s specifications: we will propose a safe, complete configuration.\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801431408932,"sku":"TURBOMAX120-9A 200","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_THERMO_2000_TURBOMAX120_9A_200_120_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082278","url":"https:\/\/airgreen.ca\/en\/products\/chauffe-eau-indirect-thermo-2000-turbomax120-9a-200-120-gallons-montreal-laval-longueuil-rive-sud-rive-nord","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}