{"product_id":"chauffe-eau-indirect-thermo-2000-turbomax80-5-80-gallons-montreal-laval-longueuil-rive-sud-rive-nord","title":"THERMO 2000 TURBOMAX80-5 Indirect Water Heater (80 gallons) | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003ch2\u003eAn 80 US gallon indirect water heater for plexes and large homes heated by an electric boiler\u003c\/h2\u003e\n\u003cp\u003eIn a duplex, a triplex or a large home heated by an \u003cstrong\u003eelectric boiler\u003c\/strong\u003e, hot water is shared between several households or several floors, and the peaks overlap. The \u003cstrong\u003eThermo 2000 TurboMax 80-5 indirect water heater\u003c\/strong\u003e answers this situation with an \u003cstrong\u003e80 US gallon\u003c\/strong\u003e tank, a \u003cstrong\u003e32.7 sq. ft. copper coil system\u003c\/strong\u003e and a maximum domestic hot water flow of \u003cstrong\u003e15 gpm\u003c\/strong\u003e. AirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhen the reserve matters more than the capacity\u003c\/h3\u003e\n\u003cp\u003eAn electric boiler is sized to heat the building, and its capacity is limited by the electrical service. That is why tank volume matters so much in a plex: it stores energy during off-peak hours and releases it when everyone opens the tap. The manufacturer’s table shows this clearly. For water at 110 °F, first-hour output reaches 1,189 US GPH, versus 1,109 US GPH continuous; the gap comes from the energy already stored in the tank. With a modest boiler, this reserve becomes the first line of defence against a lukewarm shower.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 80 US gallons\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeat exchanger:\u003c\/strong\u003e high-exchange-capacity copper coils, surface of 32.7 sq. ft.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDomestic hot water at 110 °F:\u003c\/strong\u003e maximum exchange capacity of 645,000 BTU\/h (189 kW); 1,189 US GPH first hour; 1,109 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDomestic hot water at 140 °F:\u003c\/strong\u003e maximum exchange capacity of 455,000 BTU\/h (133 kW); 581 US GPH first hour; 549 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDomestic hot water at 160 °F:\u003c\/strong\u003e maximum exchange capacity of 300,000 BTU\/h (88 kW); 316 US GPH first hour; 302 US GPH continuous\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConditions:\u003c\/strong\u003e domestic cold water at 40 °F, boiler water at 180 °F\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum domestic hot water flow:\u003c\/strong\u003e 15 gpm\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum pressure:\u003c\/strong\u003e 150 psi\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnections:\u003c\/strong\u003e potable water 1 1\/2 in male sweat; boiler 1 1\/2 in NPT male\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e height 74 3\/4 in, diameter 24 in\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 308 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePlexes and multigenerational homes\u003c\/h3\u003e\n\u003cp\u003eIn a duplex or triplex whose electric boiler serves all the units, a single indirect tank can replace several electric water heaters spread across the basements. The owner then has only one hot water unit to maintain, and the freed space can be used for something else. In a multigenerational home, the principle is the same: one tank, one heat source, and a reserve large enough that the two households do not have to organize themselves around hot water. We check with you the requirements that apply to distribution between units before proposing this configuration.\u003c\/p\u003e\n\n\u003ch3\u003eReading the maximum exchange capacity\u003c\/h3\u003e\n\u003cp\u003eThe first-hour and continuous output values assume that the boiler supplies the exchanger’s maximum exchange capacity: 645,000 BTU\/h (189 kW) for water at 110 °F. A plex electric boiler generally supplies much less. With it, the TurboMax 80-5 works the same way, but continuous output follows the boiler’s real capacity. Thermo 2000 also specifies that the values must be reduced for high-temperature and continuous-flow applications. Our quote states the output you can expect with your boiler, not the best line of the table.\u003c\/p\u003e\n\n\u003ch3\u003eA tank 74 3\/4 in tall\u003c\/h3\u003e\n\u003cp\u003eThe TurboMax 80-5 is 74 3\/4 in high and 24 in in diameter. In plex basements, where the height under the beams is often limited by piping and ducts, this measurement must be checked before ordering, adding the space needed for the top fittings. The tank weighs 308 lb empty: we plan the route down the stairs and a solid, level floor near a drain.\u003c\/p\u003e\n\n\u003ch3\u003eConnections and distribution\u003c\/h3\u003e\n\u003cp\u003ePotable water and the boiler both connect in 1 1\/2 in, male sweat on the potable water side and NPT male on the boiler side. When hot water must travel several floors, we add a recirculation loop when needed so it reaches distant taps quickly, and a \u003cstrong\u003ethermostatic mixing valve\u003c\/strong\u003e to deliver a safe temperature. The control is connected to the electric boiler with \u003cstrong\u003ehot water priority\u003c\/strong\u003e. The tank drain valve, supplied as standard, is used for yearly maintenance.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing the production temperature\u003c\/h3\u003e\n\u003cp\u003eThe temperature at which water is produced changes the quantity available. At 140 °F, the TurboMax 80-5 gives 581 US GPH in the first hour and 549 US GPH continuous; at 160 °F, 316 US GPH and 302 US GPH. In a plex, we choose the production temperature according to real uses, knowing that every increase reduces hourly output, then the thermostatic mixing valve ensures a safe temperature before the water reaches the units. This setting is discussed with you according to the occupants’ ages and the length of the piping.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer’s warranty\u003c\/h3\u003e\n\u003cp\u003eThermo 2000 offers a \u003cstrong\u003e15-year residential warranty\u003c\/strong\u003e, a \u003cstrong\u003e10-year commercial warranty\u003c\/strong\u003e and a \u003cstrong\u003e2-year warranty on mechanical components\u003c\/strong\u003e. The category applicable to your building is confirmed in writing with the quote.\u003c\/p\u003e\n\n\u003ch2\u003eInstallation of the Thermo 2000 TurboMax 80-5 by AirGreen\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family business established in Montreal, active in heating, ventilation and air conditioning for more than fifteen years and holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. For this indirect water heater, our work includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eanalysis of each unit’s needs and of the electric boiler’s capacity;\u003c\/li\u003e\n\u003cli\u003echeck of the free height, the delivery route and the floor;\u003c\/li\u003e\n\u003cli\u003eremoval of the old electric water heaters;\u003c\/li\u003e\n\u003cli\u003econnecting the potable water in 1 1\/2 in, with thermostatic mixing valve and, if needed, a recirculation loop;\u003c\/li\u003e\n\u003cli\u003econnecting to the boiler in 1 1\/2 in, with circulator, check valve and air vent;\u003c\/li\u003e\n\u003cli\u003ethe relief valve, its discharge pipe and the expansion tank;\u003c\/li\u003e\n\u003cli\u003ewiring the control, commissioning and a maintenance plan.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWe serve \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, Rosemont, Villeray, Saint-Hubert, Lachine, Sainte-Rose and the entire \u003cstrong\u003eSouth Shore\u003c\/strong\u003e and \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. The on-site estimate is free, the quote is written and \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free quote for the Thermo 2000 TurboMax 80-5.\u003c\/strong\u003e Tell us how many units share the boiler and send a photo of its rating plate: we will propose a clear configuration.\u003c\/p\u003e","brand":"Thermo 2000","offers":[{"title":"Default Title","offer_id":67801426526500,"sku":"TURBOMAX80-5","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CHAUFFE_EAU_INDIRECT_THERMO_2000_TURBOMAX80_5_80_GAL_US_00_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1793082278","url":"https:\/\/airgreen.ca\/en\/products\/chauffe-eau-indirect-thermo-2000-turbomax80-5-80-gallons-montreal-laval-longueuil-rive-sud-rive-nord","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}