{"product_id":"climatiseur-central-york-ycg-lx-2-tonnes-24000-btu-r410a","title":"YORK YCG LX Central Air Conditioner | 2 Tons - 24000 BTU - R410A","description":"\u003ch2\u003eA small York size to add central air without overloading the panel\u003c\/h2\u003e\n\u003cp\u003eAt 24,000 BTU\/h, the YCG24B21S is the 2-ton size of the York YCG (LX) series, the smallest of the 6 sizes we offer in this series. It is the outdoor unit of an R-410A central air conditioner, fitted with a single-stage scroll compressor. It is matched with an indoor section, a coil on a furnace or a fan coil, which pushes the cooled air through your ducts.\u003c\/p\u003e\n\u003cp\u003eThe YCG is a York LX R-410A condensing unit, offered from 2 to 5 tons on clearance. Its paint is tested for at least 750 hours of salt spray, more than the other LX models. The limited warranty is 10 years on the compressor, with 10 years on parts if the unit is registered.\u003c\/p\u003e\n\u003ch3\u003eWho it is for\u003c\/h3\u003e\n\u003cp\u003eThis size is aimed at condos, townhouses and modest bungalows that already have ductwork. A bigger unit would short-cycle there. A well-chosen size dehumidifies better: an oversized unit cools quickly, shuts off right away and leaves the house cool but clammy. On the electrical side, a 25 A maximum breaker is enough, which often avoids major panel work.\u003c\/p\u003e\n\u003ch3\u003eThe numbers for this size\u003c\/h3\u003e\n\u003cp\u003eThe spec sheet lists a sound power of 72 dBA. Electrical: 208\/230 V single-phase circuit, 16.4 A minimum ampacity, 25 A maximum time-delay fuse or breaker. The unit ships with a factory charge of 3.62 lb (1.64 kg) of R-410A, which our technicians adjust to the actual piping length.\u003c\/p\u003e\n\u003cp\u003eThe cabinet measures 29 1\/4 x 29 1\/4 in at the base and 30 in high, with an operating weight of 150 lb. Without accessories the manufacturer allows cooling down to 55°F (12.8°C) outdoors; a manufacturer low-ambient kit extends the range to 20°F (-7°C).\u003c\/p\u003e\n\u003cp\u003eThis model runs on R-410A, a refrigerant that manufacturers are gradually replacing with R-454B and R-32 in their new series. It is offered while our suppliers' stock lasts, and it suits replacing an R-410A condensing unit on a compatible coil.\u003c\/p\u003e\n\u003cp\u003eThis condensing unit does not heat. Sold alone, it is not eligible for the LogisVert grant. If you also want to heat with the same system, a central heat pump deserves a comparison; we can show you both.\u003c\/p\u003e\n\u003cp\u003eOther York series offered at 2 tons: \u003ca href=\"\/en\/products\/climatiseur-central-york-yc2e-lx-2-tonnes-24000-btu-r410a\"\u003eYork YC2E LX\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxt-affinity-2-tonnes-24000-btu-r410a\"\u003eYork YXT Affinity\u003c\/a\u003e, \u003ca href=\"\/en\/products\/climatiseur-central-york-yxv-affinity-2-tonnes-24000-btu-r410a\"\u003eYork YXV Affinity\u003c\/a\u003e.\u003c\/p\u003e\n\u003ch3\u003eHow the installation goes\u003c\/h3\u003e\n\u003cp\u003eOur technicians do all the work themselves, from refrigeration to electrical: AirGreen holds RBQ licence 5645-9605-01 and has been installing in Montreal for more than fifteen years.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eFree on-site estimate and size validation;\u003c\/li\u003e\n\u003cli\u003eWritten quote that specifies the matched indoor section and the electrical circuit;\u003c\/li\u003e\n\u003cli\u003eSetting the outdoor unit on a stable base and installing the indoor section;\u003c\/li\u003e\n\u003cli\u003eRefrigerant piping with a 3\/4 in vapor valve, evacuation and charge adjustment;\u003c\/li\u003e\n\u003cli\u003eElectrical connection, commissioning and airflow check at the grilles.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eThe manufacturer allows up to 80 ft of equivalent piping, which leaves room to place the unit away from a deck or a bedroom. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eLet's talk about your home\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eAsk for a free estimate: we confirm whether 2 tons is the right size, check the panel and the ducts, then give you a written quote. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":68395054137636,"sku":"YCG24B21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CLIMATISEUR_CENTRAL_YORK_YCG_YCG24B21S_00_2_TONNES_24000_BTU_R410A_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795692131","url":"https:\/\/airgreen.ca\/en\/products\/climatiseur-central-york-ycg-lx-2-tonnes-24000-btu-r410a","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}