{"product_id":"climatiseur-gainable-york-serie-r-20-seer-30000-btu","title":"YORK R Series 20 SEER Ducted Air Conditioner | 30000 BTU","description":"\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eRooms served by ducts, without multiplying visible units\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eIn a renovation in \u003cstrong\u003eMontreal\u003c\/strong\u003e, a residential project in \u003cstrong\u003eLaval\u003c\/strong\u003e, or an office project in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, we can consider air conditioning without placing a visible unit on every wall. The \u003cstrong\u003eYORK R Series 30,000 BTU ducted air conditioner\u003c\/strong\u003e uses a concealed indoor unit connected to ducts that deliver air to ceiling or wall grilles. YORK specifically provides for its installation above a suspended ceiling or in an open storage space suitable for the equipment. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eAt \u003cstrong\u003eAirGreen\u003c\/strong\u003e, we approach a ducted project by considering the equipment, ductwork, and technical access together. Our experience with this type of installation leads us to consider return air, building constraints, and future maintenance from the planning stage onward. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor the pairing presented here, the documented efficiency is 16 SEER.\u003c\/strong\u003e The designation \"R Series 20 SEER\" refers to a range that can reach 20 SEER, not to the efficiency of all its configurations. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eThe correct pairing: DHR30NDB21S indoors and DHR30CSB21S outdoors\u003c\/h3\u003e\n\u003cp\u003eWe identify this version by the \u003cstrong\u003eDHR30NDB21S\u003c\/strong\u003e ducted indoor unit, paired with the \u003cstrong\u003eDHR30CSB21S\u003c\/strong\u003e outdoor unit. These references distinguish it from the ceiling cassette or floor-ceiling unit offered in the same series. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eOur product sheet lists \u003cstrong\u003eAHRI 8578445\u003c\/strong\u003e as the reference for this system.\u003c\/p\u003e\n\u003cp\u003eAlthough its commercial name uses the word \u003cstrong\u003eair conditioner\u003c\/strong\u003e, the catalog classifies this system as a \u003cstrong\u003eheat pump\u003c\/strong\u003e: we can therefore examine its use for cooling and heating, within the published operating limits. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eThe performance specific to the 30,000 BTU ducted format\u003c\/h3\u003e\n\u003cp\u003eThe table dedicated to ducted units, on \u003cstrong\u003epage 19 of the YORK catalog - page 21 of the PDF\u003c\/strong\u003e, provides the following specifications for the DHR30NDB21S:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer TyagGW_tableContainerWithTableOfContents\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003ePublished value\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated cooling capacity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e28,200 BTU\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling capacity range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8,200 to 29,600 BTU\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated heating capacity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e31,200 BTU\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating capacity range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8,200 to 33,600 BTU\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeasonal cooling efficiency\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e16 SEER\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstantaneous cooling efficiency\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e8.55 EER\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeasonal heating efficiency\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9 HSPF\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePublished maximum airflow\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e826 CFM\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndicated static pressure range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0 to 0.8 in. of water column\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThese figures come from the \u003cstrong\u003educted model\u003c\/strong\u003e column, not from that of another indoor unit in the R Series. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWe therefore distinguish the commercial \u003cstrong\u003e30,000 BTU\u003c\/strong\u003e category from the manufacturer's stated nominal capacity of \u003cstrong\u003e28,200 BTU\/h\u003c\/strong\u003e. We also retain the \u003cstrong\u003eSEER, EER, and HSPF\u003c\/strong\u003e ratings from this documentation, without presenting them as SEER2, EER2, or HSPF2 values. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe R Series is equipped with a \u003cstrong\u003evariable-speed compressor\u003c\/strong\u003e. This modulation is one of the characteristics to examine alongside the building's needs, particularly when room usage varies throughout the day. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eMultiple grilles do not mean multiple independent temperatures\u003c\/h3\u003e\n\u003cp\u003eThe configuration presented belongs to the \u003cstrong\u003esingle-zone\u003c\/strong\u003e system family, consisting of an outdoor unit and an indoor unit. The ducted version then distributes the air through a duct network. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWe therefore separate two decisions: \u003cstrong\u003ethe rooms to be served\u003c\/strong\u003e and \u003cstrong\u003ethe desired level of independence between them\u003c\/strong\u003e. A homeowner who wants a common setpoint for several spaces does not have the same needs as a homeowner who wants to adjust each bedroom separately.\u003c\/p\u003e\n\u003cp\u003eFor your proposal, we suggest identifying the priority rooms, their occupancy schedules, and the temperature differences currently observed. We do not infer the number of adjustable zones from the number of supply registers alone.\u003c\/p\u003e\n\u003ch3\u003eStatic pressure and airflow: two figures to read together\u003c\/h3\u003e\n\u003cp\u003eYORK describes this unit as a \u003cstrong\u003emedium-static-pressure\u003c\/strong\u003e model and publishes a range up to \u003cstrong\u003e0.8 in. of water column\u003c\/strong\u003e. The catalog also provides the available airflow rates, but on this page it does not present a complete curve linking each airflow rate to each pressure. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor the design, we compare these characteristics with the planned duct network: run lengths, changes in direction, connections, and grilles. We want to verify how the system is expected to operate as a whole, rather than relying solely on the \u003cstrong\u003e826 CFM\u003c\/strong\u003e figure.\u003c\/p\u003e\n\u003cp\u003eThis value corresponds to the unit’s published maximum airflow rate. We present it neither as the airflow rate of each grille nor as a guarantee of results for any duct network.\u003c\/p\u003e\n\u003ch3\u003eA sound level linked to the selected speed\u003c\/h3\u003e\n\u003cp\u003eThe brochure associates the four airflow rates, \u003cstrong\u003e826, 767, 708, and 531 ft³\/min\u003c\/strong\u003e, with the respective indoor sound pressure levels of \u003cstrong\u003e47, 46, 44, and 40 dB(A)\u003c\/strong\u003e. We compare these values in pairs: the maximum airflow rate and minimum sound level do not correspond to the same setting. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor the outdoor unit \u003cstrong\u003eDHR30CSB21S\u003c\/strong\u003e, the published level is \u003cstrong\u003e58 dB(A)\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIn our installation proposal, we pay particular attention to areas where noise would be most disruptive: near a home office, bedroom, or terrace. We define acoustic expectations before installation, without promising that a concealed unit will necessarily be inaudible.\u003c\/p\u003e\n\u003ch3\u003eHeating down to −18 °C: clarify the system’s role in winter\u003c\/h3\u003e\n\u003cp\u003eThe outdoor unit has a heating operating range of \u003cstrong\u003e−18 to 24 °C\u003c\/strong\u003e. In cooling mode, the published range is \u003cstrong\u003e−18 to 46 °C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe rated heating capacity of \u003cstrong\u003e31,200 BTU\/h\u003c\/strong\u003e is nevertheless given under the catalog’s test conditions, which notably indicate an outdoor temperature of \u003cstrong\u003e8 °C dry-bulb\u003c\/strong\u003e. We therefore do not automatically attribute it to operation at −18 °C. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe technical page does not provide capacity or coefficient of performance figures specific to −15 °C or −18 °C. For a project on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, or in \u003cstrong\u003eMontérégie\u003c\/strong\u003e, we propose explicitly determining the expected contribution of this heat pump and the role of supplemental heating. The minimum operating temperature is not sufficient to justify removing an existing heating system.\u003c\/p\u003e\n\u003ch2\u003eDesign the ducted installation around the building, the ducts, and maintenance\u003c\/h2\u003e\n\u003ch3\u003eDraw the supply and return air routes before choosing the grilles\u003c\/h3\u003e\n\u003cp\u003eIn addition to the catalog, the \u003cstrong\u003eYORK installation manual\u003c\/strong\u003e separately illustrates the supply duct, return air, filter, and connections to the unit. The distribution diagram confirms that the project is not limited to the visible outlets in the rooms. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a renovation study in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, for example, we might start with a plan comprising two bedrooms, an office, and a corridor. We would then ask where to place the supply outlets, how to arrange the return, and which access points to preserve. This is a \u003cstrong\u003edesign scenario\u003c\/strong\u003e, not an installation assigned to this YORK model.\u003c\/p\u003e\n\u003cp\u003eOne detail in the manual also deserves to be retained: the bottom-return configuration illustrated in this section is specified for \u003cstrong\u003e18,000 BTU units only\u003c\/strong\u003e. We do not apply this option to the 30,000 BTU model without technical confirmation. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eA 50 × 22 × 11 in cabinet that must remain accessible\u003c\/h3\u003e\n\u003cp\u003eThe indoor unit \u003cstrong\u003eDHR30NDB21S\u003c\/strong\u003e measures \u003cstrong\u003e50 × 22 × 11 in\u003c\/strong\u003e, in the order \u003cstrong\u003ewidth × depth × height\u003c\/strong\u003e, or approximately \u003cstrong\u003e1,270 × 559 × 279 mm\u003c\/strong\u003e. Its published net weight is \u003cstrong\u003e34 kg\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWe do not treat these dimensions as the project's complete required opening. In the installation plan, we also allow for the space needed for connections and future servicing.\u003c\/p\u003e\n\u003cp\u003eFor the outdoor unit, the catalog lists the dimensions as \u003cstrong\u003e39 × 31 × 17 in\u003c\/strong\u003e. We retain their published order here; their orientation and installation clearances must be confirmed on the applicable technical drawing before preparing the support. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eOur recommendation is simple: \u003cstrong\u003eprovide service access before closing the ceiling\u003c\/strong\u003e. We want to be able to reach the components requiring inspection without turning a service call into a finishing project.\u003c\/p\u003e\n\u003ch3\u003eTwo power supplies to include in the quote\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer specifies that the indoor and outdoor units require \u003cstrong\u003eseparate power supplies\u003c\/strong\u003e. They operate on a nominal \u003cstrong\u003e208\/230 V, single-phase, 60 Hz\u003c\/strong\u003e power supply, with different requirements:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer TyagGW_tableContainerWithTableOfContents\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eElectrical data\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eOutdoor unit DHR30CSB21S\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eIndoor unit DHR30NDB21S\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Circuit Ampacity — MCA\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e24 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e2 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Overcurrent Protection — MOCP\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e40 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e15 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThese values come from the tables specific to the two units. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e \u003cspan class=\"contents\"\u003e\u003c\/span\u003e \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWe have the qualified professional size the conductors and protection devices based on the documentation and nameplate of the delivered equipment. A maximum protection of \u003cstrong\u003e40 A\u003c\/strong\u003e does not describe a continuous consumption of 40 A.\u003c\/p\u003e\n\u003ch3\u003eRefrigerant, piping, and condensate: three separate checks\u003c\/h3\u003e\n\u003cp\u003eThis system uses \u003cstrong\u003eR-410A\u003c\/strong\u003e. The published refrigerant connections for the ducted version are \u003cstrong\u003e3\/8 in. for liquid\u003c\/strong\u003e and \u003cstrong\u003e5\/8 in. for gas\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor the 30,000 BTU outdoor unit, the catalog states a maximum total piping length of \u003cstrong\u003e50 m\u003c\/strong\u003e and a maximum elevation difference of \u003cstrong\u003e15 m\u003c\/strong\u003e. We use these limits to assess the feasibility of the route; they do not define the length included in an installation quote. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eintegrated condensate pump\u003c\/strong\u003e is one of the components described for the ducted unit. The indoor drain connection is specified as having a \u003cstrong\u003e1 in. outside diameter\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDuring our job preparation, we identify the drainage route and access to the pump. We propose checking the drainage before finishing work, then keeping its location in the installation file.\u003c\/p\u003e\n\u003ch3\u003eDWCR wired controller and Wi-Fi: knowing what is actually included\u003c\/h3\u003e\n\u003cp\u003eThe ducted-model page lists the \u003cstrong\u003eDWCR wired zone controller as standard equipment\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eOur sales sheet mentions \u003cstrong\u003eoptional Wi-Fi\u003c\/strong\u003e. However, the brochure does not provide a Wi-Fi module reference for this pairing. Its presentation of the \u003cstrong\u003eEWPE Smart\u003c\/strong\u003e app targets the P, X, and Z series; it therefore does not confirm this app for the R Series. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWe have the compatible accessory identified before including a telephone control in the quote. For a homeowner primarily looking for a weekly schedule, the catalog also describes the \u003cstrong\u003eDWCR2\u003c\/strong\u003e controller for the R Series, with seven-day programming and locking functions. Its supply and compatibility with the selected configuration remain to be specified. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eOur ducted-system projects: three constraints, three on-site solutions\u003c\/h3\u003e\n\u003cp\u003eThe following examples come from our \u003cstrong\u003epublished projects\u003c\/strong\u003e. They involve GREE and Fujitsu equipment and illustrate our integration work without attributing their features or results to the YORK model presented.\u003c\/p\u003e\n\u003ch4\u003eIn Montreal: routing the ducts through a renovated space\u003c\/h4\u003e\n\u003cp\u003eDuring the installation of an \u003cstrong\u003e18,000 BTU GREE ducted system in Montreal\u003c\/strong\u003e, we worked with restricted attic access and little space between the walls. The routing of the ducts had to preserve the renovated layout. We organized their path to three discreet outlets, with the goal of keeping the network out of sight. This project illustrates why we examine the available pathways before definitively setting the unit's position. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eIn Laval: maintaining access around a recessed unit\u003c\/h4\u003e\n\u003cp\u003eIn \u003cstrong\u003eSaint-Vincent-de-Paul, Laval\u003c\/strong\u003e, our installation of a \u003cstrong\u003eGREE All Match Slim Duct R32\u003c\/strong\u003e took place in an especially tight mechanical space. We coordinated the positioning of the unit, the connections, and the return air while keeping future maintenance among the installation criteria. The constraint was not only getting the unit in: we also had to preserve the ability to service it. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003eIn Brossard: addressing an acoustic concern\u003c\/h4\u003e\n\u003cp\u003eOn the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, our installation of an \u003cstrong\u003e18,000 BTU Fujitsu ducted system in Brossard\u003c\/strong\u003e included a concealed network and three air outlets. The owner placed particular importance on noise, so we incorporated soundproofing measures and carefully insulated the ducts. The customer feedback reported in our summary highlighted the comfort achieved and the discreet nature of the installation. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eHVAC maintenance covering the entire system\u003c\/h3\u003e\n\u003cp\u003eFor your \u003cstrong\u003eHVAC maintenance\u003c\/strong\u003e, we recommend keeping a sheet indicating access to the filter, unit, and drainage, as well as the control references. Our experience with installations in tight spaces shows the importance of maintaining this access after the work is completed. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eBetween visits, we invite you to report any persistent change in noise, perceived airflow, or comfort. To prepare for a diagnosis, note the setpoint, the mode used, the rooms affected, and any displayed code. These observations help describe the problem without prematurely concluding that there is a compressor failure or a lack of refrigerant.\u003c\/p\u003e\n\u003cp\u003eWe also recommend not blocking the grilles with furniture and not closing all the outlets: the YORK manual requires keeping at least one supply outlet open. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eA warranty tied to the installation conditions\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e10-10-0\u003c\/strong\u003e notation on our sheet means \u003cstrong\u003eten years for the compressor, ten years for the parts, and no years of labor included in this designation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe 2020 YORK catalogue presents standard coverage of \u003cstrong\u003eseven years for the compressor and five years for parts\u003c\/strong\u003e, followed by an extension to ten years after registration for eligible residential installations. Coverage including labor is also described, with the purchase of additional coverage. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWe therefore have the applicable conditions for the system being sold, whether the premises are for residential or commercial use, and the additional protections selected clearly specified. The quote should distinguish the stated duration from the costs actually covered.\u003c\/p\u003e\n\u003ch3\u003eCompare the installed price without assuming a grant\u003c\/h3\u003e\n\u003cp\u003eFor your \u003cstrong\u003educted air conditioner installation\u003c\/strong\u003e, we suggest having three price components itemized: the equipment and its controls, the duct network and connections, and related work such as openings and finishing.\u003c\/p\u003e\n\u003cp\u003eThis breakdown helps explain why two quotes for the same appliance may cover different work. In particular, we want the number of grilles, the return air, service access, and electrical work to be identified.\u003c\/p\u003e\n\u003cp\u003eOur product sheet states \u003cstrong\u003eENERGY STAR®: no\u003c\/strong\u003e and \u003cstrong\u003ecold-climate certification: no\u003c\/strong\u003e. Hydro-Québec specifies that heat pumps installed as of \u003cstrong\u003eNovember 26, 2025\u003c\/strong\u003e must be ENERGY STAR® certified to qualify for the corresponding LogisVert grant. \u003cstrong\u003eBased on the information provided for this YORK system, we therefore do not anticipate this grant in its budget.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eLet's prepare your ducted system project with AirGreen\u003c\/h3\u003e\n\u003cp\u003eWe offer a \u003cstrong\u003efree on-site estimate\u003c\/strong\u003e in \u003cstrong\u003eGreater Montreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e, and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. Our support includes equipment selection, installation, and after-sales service. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eTo prepare for this meeting, we invite you to gather a floor plan of the rooms to be served, a few photos of the mechanical spaces, and a description of the existing heating system. This will allow us to assess the project beyond the stated capacity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact AirGreen at 514-316-2973 or at \u003ca class=\"decorated-link cursor-pointer\" rel=\"noopener\"\u003esales@airgreen.ca\u003c\/a\u003e to check the availability of the 30,000 BTU YORK ducted system, have its integration assessed, and obtain a quote tailored to your building.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56157183246628,"sku":"DHR30CSB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_CLIMATISEUR_GAINABLE_YORK_SERIE_R_30000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_7d5bc389-915a-44b1-b97b-0ee55a9247e9.png?v=1789500683","url":"https:\/\/airgreen.ca\/en\/products\/climatiseur-gainable-york-serie-r-20-seer-30000-btu","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}