{"product_id":"controleur-mural-general-airstage-uty-rvnum-montreal-laval-longueuil-rive-sud-rive-nord","title":"Wall Controller GENERAL AIRSTAGE UTY-RVNUM | Montreal, Laval, Longueuil, South Shore \u0026 North Shore","description":"\u003cp\u003eGENERAL or Fujitsu \u003cstrong\u003efloor consoles\u003c\/strong\u003e are popular in Québec: installed under a window or in the basement, they blow heat at floor level, where the cold is felt first. To control them, however, people often make do with a small remote that ends up going astray. The GENERAL AIRSTAGE UTY-RVNUM \u003cstrong\u003ewired wall controller\u003c\/strong\u003e settles the matter with a \u003cstrong\u003elarge backlit LCD screen\u003c\/strong\u003e mounted on the wall, which shows the room temperature and opens access to a complete \u003cstrong\u003eweekly timer\u003c\/strong\u003e. It is the same part as the UTY-RVNUM sold under the Fujitsu AIRSTAGE name, since Fujitsu General Limited became GENERAL Inc. on January 1, 2026.\u003c\/p\u003e\n\u003cp\u003eOnly the brand changes. The manufacturer, now owned by Paloma Rheem Holdings, produces the same controller in the same factories, under the same model number, and the Fujitsu name will gradually fade out in favour of GENERAL. In the meantime, AirGreen, an authorized GENERAL and Fujitsu AIRSTAGE dealer, offers this GENERAL model as well as \u003ca href=\"https:\/\/airgreen.ca\/products\/controleur-mural-fujitsu-uty-rvnum-montreal-laval-longueuil-rive-sud-rive-nord\"\u003ethe same part under the Fujitsu AIRSTAGE brand\u003c\/a\u003e.\u003c\/p\u003e\n\n\u003ch2\u003eA 3-wire controller designed for floor consoles\u003c\/h2\u003e\n\u003cp\u003eThe UTY-RVNUM is intended for \u003cstrong\u003e3-wire indoor units\u003c\/strong\u003e, GENERAL or Fujitsu, and first of all for \u003cstrong\u003efloor\u003c\/strong\u003e models. The manufacturer also reports limited compatibility with certain single-zone \u003cstrong\u003ewall-mounted heat pumps\u003c\/strong\u003e, according to its compatibility chart. We therefore start by noting the exact model number of your indoor unit before offering you this controller; if the unit is not on the chart, we steer you toward the controller that suits it.\u003c\/p\u003e\n\u003cp\u003ePower comes from the indoor unit: \u003cstrong\u003e12 VDC\u003c\/strong\u003e, 1.2 W maximum. The connection is made with a \u003cstrong\u003esheathed, polarized 3-conductor PVC cable\u003c\/strong\u003e, and that polarity is unforgiving: each conductor has to land on the right terminal, which calls for rigorous work. It is in fact one of the reasons we recommend leaving the installation to a technician.\u003c\/p\u003e\n\n\u003ch3\u003eWeekly schedules and setpoint limits\u003c\/h3\u003e\n\u003cp\u003eThe UTY-RVNUM's \u003cstrong\u003eweekly timer\u003c\/strong\u003e can start or stop the unit, \u003cstrong\u003echange the mode\u003c\/strong\u003e and \u003cstrong\u003eadjust the setpoint\u003c\/strong\u003e by time and day. \u003cstrong\u003eAutomatic shutoff\u003c\/strong\u003e, for its part, turns the unit off after a preset time: very handy in a playroom, a workshop or any room where people often forget to switch it off.\u003c\/p\u003e\n\u003cp\u003eThe controller also lets you impose a \u003cstrong\u003emaximum setpoint and a minimum setpoint for each mode\u003c\/strong\u003e. In a rental unit, an office or a common room, these limits prevent overheating in winter or overcooling in summer, while leaving occupants a reasonable margin of adjustment.\u003c\/p\u003e\n\n\u003ch3\u003eTwo controllers for one unit, or one for sixteen\u003c\/h3\u003e\n\u003cp\u003eThe UTY-RVNUM lends itself to flexible setups. \u003cstrong\u003eTwo controllers can run the same unit\u003c\/strong\u003e, which is convenient in a large room with two entrances, or in a basement where you want one control at the top of the stairs and another near the console. Conversely, a single controller can manage \u003cstrong\u003eup to 16 indoor units\u003c\/strong\u003e, a useful formula for a commercial space or an open area equipped with several consoles. The screen is also \u003cstrong\u003emultilingual\u003c\/strong\u003e, an advantage in buildings where occupants come and go.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eType\u003c\/strong\u003e: programmable 3-wire wired wall controller\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCompatible systems\u003c\/strong\u003e: 3-wire GENERAL or Fujitsu indoor units, mainly floor units; some single-zone wall-mounted units per the manufacturer's chart\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e: large backlit LCD, room temperature display, multilingual interface\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eProgramming\u003c\/strong\u003e: weekly timer (on\/off, mode change, setpoint change); automatic shutoff after a preset time\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eLimits\u003c\/strong\u003e: maximum and minimum setpoints per mode\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eGroup control\u003c\/strong\u003e: up to 16 indoor units\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDual control\u003c\/strong\u003e: two controllers on the same unit\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e: 12 VDC from the indoor unit, 1.2 W max.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCable\u003c\/strong\u003e: sheathed PVC, 3 conductors, polarized\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e: wired, 3-wire\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDimensions (H x W x D)\u003c\/strong\u003e: 4-23\/32 x 4-23\/32 x 27\/32 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOperating conditions\u003c\/strong\u003e: from 32 to 114 °F and from 0 to 95% RH\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAgainst the other 3-wire controllers\u003c\/h3\u003e\n\u003cp\u003eIn the manufacturer's family of 3-wire controllers, the UTY-RSNUM serves as the simplified model: it handles modes and temperature, without weekly programming. The UTY-RNBYU, with its timer and built-in sensor, is aimed instead at other previous-generation equipment: wall-mounted units, ceiling units and cassettes. What sets the UTY-RVNUM apart: the large backlit multilingual screen, setpoint limits specific to each mode and dual control. For a floor console that works hard, it is the most complete choice.\u003c\/p\u003e\n\u003cp\u003eWe recommend it above all for finished basements, additions to an existing house, enclosed verandas and small businesses where a console provides the main heating. In these spaces, a readable wall control, programmed once and for all, makes life easier for everyone.\u003c\/p\u003e\n\n\u003ch2\u003eAirGreen handles installation, settings and maintenance\u003c\/h2\u003e\n\u003cp\u003eThe controller's location is decided with you; our technicians then pull the 3-conductor cable from the console to the wall, land each conductor on its terminal and mount the housing. If two controllers run the same unit, or if several units report to one controller, we configure the addressing and test each combination. What remains after that is programming the weekly timer, choosing the display language and, where applicable, setting the setpoint limits.\u003c\/p\u003e\n\n\u003ch3\u003eSaving energy during the winter\u003c\/h3\u003e\n\u003cp\u003eA floor console heats a room best when its setpoint is steady. With the UTY-RVNUM's weekly timer, you apply moderate setbacks at night or during absences, instead of full shutdowns that force the unit to restart hard when it is very cold. In a basement that sees little use during the week, you hold a base temperature and only return to comfort in the evening or on the weekend. In rental units, the setpoint limits per mode round out these savings.\u003c\/p\u003e\n\n\u003ch3\u003eOur maintenance tips\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eA console's filter gets dirty fast: sitting close to the floor, it draws in more dust than a wall-mounted unit, so clean it regularly.\u003c\/li\u003e\n\u003cli\u003eDo not block the front of the console with furniture or curtains, so that the air circulates freely.\u003c\/li\u003e\n\u003cli\u003eRun a soft, dry cloth over the controller's screen.\u003c\/li\u003e\n\u003cli\u003eWhen the power comes back after a long outage, check the time and the programs.\u003c\/li\u003e\n\u003cli\u003eBook an annual inspection of the unit with our technicians.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eWhy AirGreen\u003c\/h3\u003e\n\u003cp\u003eAirGreen Inc., a family-owned air conditioning and heating company holding an RBQ licence, has been practising the trade for more than 15 years. In our Boucherville showroom, you can see several types of indoor units, including floor consoles, and our technicians have mastered the connection specifics of 3-wire GENERAL and Fujitsu equipment.\u003c\/p\u003e\n\u003cp\u003eFor the purchase and installation of the GENERAL AIRSTAGE UTY-RVNUM wall controller, contact AirGreen. We work in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n","brand":"GENERAL","offers":[{"title":"Default Title","offer_id":67944736588068,"sku":"UTY-RVNUM","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_CONTROLEUR_MURAL_GENERAL_AIRSTAGE_UTY-RVNUM_CARTE_PRINCIPALE_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_a814a08f-fb36-4350-a471-62571e108b9b.png?v=1793182831","url":"https:\/\/airgreen.ca\/en\/products\/controleur-mural-general-airstage-uty-rvnum-montreal-laval-longueuil-rive-sud-rive-nord","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}