{"product_id":"fournaise-electrique-fujitsu-centauri-xlth-r32-4-tonnes-48000-btu","title":"FUJITSU CENTAURI XLTH R32 Electric Furnace | 4 Tons - 48000 BTU","description":"\u003ch2 data-section-id=\"1fa01as\" data-start=\"90\" data-end=\"165\"\u003eA High-Performance Central Solution Designed for Quebec Winters\u003c\/h2\u003e\n\u003cp data-start=\"167\" data-end=\"643\"\u003eAt AirGreen, we daily install HVAC systems tailored to the demanding climate realities of \u003cstrong data-start=\"279\" data-end=\"297\"\u003eGreater Montreal\u003c\/strong\u003e, \u003cstrong data-start=\"302\" data-end=\"311\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"316\" data-end=\"329\"\u003eLongueuil\u003c\/strong\u003e, as well as the \u003cstrong data-start=\"347\" data-end=\"360\"\u003eNorth Shore\u003c\/strong\u003e and \u003cstrong data-start=\"370\" data-end=\"382\"\u003eSouth Shore\u003c\/strong\u003e. The \u003cstrong data-start=\"387\" data-end=\"458\"\u003eFUJITSU CENTAURI XLTH R32 4-ton (48000 BTU) electric furnace\u003c\/strong\u003e fits this logic: a central solution designed to offer \u003cstrong data-start=\"535\" data-end=\"584\"\u003estable heating performance down to -30°C\u003c\/strong\u003e, while maintaining excellent energy efficiency.\u003c\/p\u003e\n\u003cp data-start=\"645\" data-end=\"861\"\u003eThis model, combined with the compatible \u003cstrong data-start=\"701\" data-end=\"716\"\u003eAOUH48KUAH1\u003c\/strong\u003e central heat pump, represents a strategic option for homeowners who wish to optimize their comfort while reducing their energy consumption.\u003c\/p\u003e\n\u003chr data-start=\"863\" data-end=\"866\"\u003e\n\u003ch2 data-section-id=\"gd9f3d\" data-start=\"868\" data-end=\"939\"\u003eUnderstanding the True Power of a FUJITSU CENTAURI XLTH Furnace\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1vyl4yu\" data-start=\"941\" data-end=\"1000\"\u003eThermal Capacity and Performance in Real Conditions\u003c\/h3\u003e\n\u003cp data-start=\"1002\" data-end=\"1166\"\u003eUnlike many systems that rapidly lose efficiency at low temperatures, this furnace stands out for its measured and reliable performance:\u003c\/p\u003e\n\u003cul data-start=\"1168\" data-end=\"1320\"\u003e\n\u003cli data-section-id=\"1r94wkq\" data-start=\"1168\" data-end=\"1204\"\u003e\u003cstrong data-start=\"1170\" data-end=\"1204\"\u003eNominal Capacity: 48,000 BTU\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1dwa4yt\" data-start=\"1205\" data-end=\"1240\"\u003e\u003cstrong data-start=\"1207\" data-end=\"1240\"\u003ePower at -8°C: 34,000 BTU\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"18dzzga\" data-start=\"1241\" data-end=\"1277\"\u003e\u003cstrong data-start=\"1243\" data-end=\"1277\"\u003ePower at -15°C: 51,000 BTU\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"150b6gz\" data-start=\"1278\" data-end=\"1320\"\u003e\u003cstrong data-start=\"1280\" data-end=\"1320\"\u003eGuaranteed operation down to -30°C\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1322\" data-end=\"1583\"\u003eIn our installations in \u003cstrong data-start=\"1347\" data-end=\"1359\"\u003eMontreal\u003c\/strong\u003e and \u003cstrong data-start=\"1366\" data-end=\"1380\"\u003eMontérégie\u003c\/strong\u003e, we have found that this type of system maintains constant comfort even during extreme cold spells. This prevents frequent short cycling and improves the overall durability of the equipment.\u003c\/p\u003e\n\u003ch3 data-section-id=\"y253uy\" data-start=\"1585\" data-end=\"1619\"\u003eAdvanced Energy Efficiency\u003c\/h3\u003e\n\u003cp data-start=\"1621\" data-end=\"1698\"\u003eThe FUJITSU CENTAURI XLTH stands out with solid technical indicators:\u003c\/p\u003e\n\u003cul data-start=\"1700\" data-end=\"1782\"\u003e\n\u003cli data-section-id=\"2qm3ic\" data-start=\"1700\" data-end=\"1719\"\u003e\u003cstrong data-start=\"1702\" data-end=\"1719\"\u003eSEER2: 19.03\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"q3r1b5\" data-start=\"1720\" data-end=\"1739\"\u003e\u003cstrong data-start=\"1722\" data-end=\"1739\"\u003eHSPF2: 10.21\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1ekyfks\" data-start=\"1740\" data-end=\"1758\"\u003e\u003cstrong data-start=\"1742\" data-end=\"1758\"\u003eEER2: 11.22\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"fq7vc\" data-start=\"1759\" data-end=\"1782\"\u003e\u003cstrong data-start=\"1761\" data-end=\"1782\"\u003eCOP at -8°C: 1.96\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1784\" data-end=\"2011\"\u003eThese data indicate an ability to produce more thermal energy than it consumes, a key factor in reducing operating costs in regions like \u003cstrong data-start=\"1955\" data-end=\"1964\"\u003eLaval\u003c\/strong\u003e or the \u003cstrong data-start=\"1971\" data-end=\"1984\"\u003eNorth Shore\u003c\/strong\u003e, where winters are long.\u003c\/p\u003e\n\u003chr data-start=\"2013\" data-end=\"2016\"\u003e\n\u003ch2 data-section-id=\"10hv7xe\" data-start=\"2018\" data-end=\"2087\"\u003eHVAC Installation: What We Do Differently at AirGreen\u003c\/h2\u003e\n\u003ch3 data-section-id=\"537cyq\" data-start=\"2089\" data-end=\"2139\"\u003eA Rigorous Approach from the First Visit\u003c\/h3\u003e\n\u003cp data-start=\"2141\" data-end=\"2364\"\u003eDuring a recent project in \u003cstrong data-start=\"2167\" data-end=\"2180\"\u003eLongueuil\u003c\/strong\u003e, our team replaced an inefficient old central system with this FUJITSU furnace. The main challenge: a restricted mechanical space with poorly optimized existing ducts.\u003c\/p\u003e\n\u003cp data-start=\"2366\" data-end=\"2395\"\u003eOur intervention included:\u003c\/p\u003e\n\u003cul data-start=\"2397\" data-end=\"2599\"\u003e\n\u003cli data-section-id=\"1rlk03k\" data-start=\"2397\" data-end=\"2461\"\u003eComplete re-evaluation of airflow (\u003cstrong data-start=\"2437\" data-end=\"2451\"\u003eCFM: 1160\u003c\/strong\u003e optimized)\u003c\/li\u003e\n\u003cli data-section-id=\"d40n9d\" data-start=\"2462\" data-end=\"2521\"\u003eDuct adjustment to reduce pressure losses\u003c\/li\u003e\n\u003cli data-section-id=\"16widxv\" data-start=\"2522\" data-end=\"2599\"\u003eInstallation in compliance with RBQ standards with electrical protection (MOP: 40A)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2601\" data-end=\"2716\"\u003eResult: an immediate improvement in thermal comfort and a measured reduction in energy consumption.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1f41wbq\" data-start=\"2718\" data-end=\"2755\"\u003eTechnical Installation Details\u003c\/h3\u003e\n\u003cul data-start=\"2757\" data-end=\"2900\"\u003e\n\u003cli data-section-id=\"19z6ghj\" data-start=\"2757\" data-end=\"2807\"\u003e\u003cstrong data-start=\"2759\" data-end=\"2807\"\u003eIndoor dimensions: 21 x 21 x 48 inches\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"16xaxqo\" data-start=\"2808\" data-end=\"2828\"\u003e\u003cstrong data-start=\"2810\" data-end=\"2828\"\u003eVoltage: 220V\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"yadqe2\" data-start=\"2829\" data-end=\"2857\"\u003e\u003cstrong data-start=\"2831\" data-end=\"2857\"\u003ePiping: 3\/8 - 5\/8\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"754po1\" data-start=\"2858\" data-end=\"2900\"\u003e\u003cstrong data-start=\"2860\" data-end=\"2900\"\u003eDehumidification: 4.7 pints\/hour\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2902\" data-end=\"3062\"\u003eThese specifications allow for flexible integration into most residences in \u003cstrong data-start=\"2992\" data-end=\"3010\"\u003eGreater Montreal\u003c\/strong\u003e, including single-family homes and duplexes.\u003c\/p\u003e\n\u003chr data-start=\"3064\" data-end=\"3067\"\u003e\n\u003ch2 data-section-id=\"r7pics\" data-start=\"3069\" data-end=\"3116\"\u003eWhy R-32 Refrigerant Changes the Game\u003c\/h2\u003e\n\u003cp data-start=\"3118\" data-end=\"3206\"\u003eThe transition to \u003cstrong data-start=\"3132\" data-end=\"3140\"\u003eR-32\u003c\/strong\u003e represents a significant evolution in the \u003cstrong data-start=\"3196\" data-end=\"3204\"\u003eHVAC\u003c\/strong\u003e field:\u003c\/p\u003e\n\u003cul data-start=\"3208\" data-end=\"3323\"\u003e\n\u003cli data-section-id=\"6hxfam\" data-start=\"3208\" data-end=\"3239\"\u003eReduced environmental impact\u003c\/li\u003e\n\u003cli data-section-id=\"16q4ah\" data-start=\"3240\" data-end=\"3272\"\u003eImproved thermal efficiency\u003c\/li\u003e\n\u003cli data-section-id=\"11tx6ph\" data-start=\"3273\" data-end=\"3323\"\u003eReduced refrigerant charge needed\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3325\" data-end=\"3498\"\u003eIn several projects in \u003cstrong data-start=\"3350\" data-end=\"3359\"\u003eLaval\u003c\/strong\u003e and on the \u003cstrong data-start=\"3370\" data-end=\"3382\"\u003eSouth Shore\u003c\/strong\u003e, we have observed a notable improvement in overall performance compared to older R-410A systems.\u003c\/p\u003e\n\u003chr data-start=\"3500\" data-end=\"3503\"\u003e\n\u003ch2 data-section-id=\"azr2k0\" data-start=\"3505\" data-end=\"3548\"\u003eSubsidies and Return on Investment\u003c\/h2\u003e\n\u003ch3 data-section-id=\"112hwly\" data-start=\"3550\" data-end=\"3600\"\u003eLogisVert Program: A Concrete Opportunity\u003c\/h3\u003e\n\u003cp data-start=\"3602\" data-end=\"3753\"\u003eThe FUJITSU CENTAURI XLTH furnace is eligible for a \u003cstrong data-start=\"3658\" data-end=\"3697\"\u003esubsidy of up to $4080\u003c\/strong\u003e via the LogisVert program (updated November 2025).\u003c\/p\u003e\n\u003cp data-start=\"3755\" data-end=\"3808\"\u003eIn a real case in \u003cstrong data-start=\"3774\" data-end=\"3790\"\u003eBoucherville\u003c\/strong\u003e, a client was able to:\u003c\/p\u003e\n\u003cul data-start=\"3810\" data-end=\"3946\"\u003e\n\u003cli data-section-id=\"1rrhnqq\" data-start=\"3810\" data-end=\"3851\"\u003eReduce their initial installation cost\u003c\/li\u003e\n\u003cli data-section-id=\"kbijzx\" data-start=\"3852\" data-end=\"3908\"\u003eAchieve a return on investment in less than 5 years\u003c\/li\u003e\n\u003cli data-section-id=\"114linr\" data-start=\"3909\" data-end=\"3946\"\u003eImprove the value of their property\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"eeinr5\" data-start=\"3948\" data-end=\"3975\"\u003eENERGY STAR Eligibility\u003c\/h3\u003e\n\u003cul data-start=\"3977\" data-end=\"4045\"\u003e\n\u003cli data-section-id=\"1t94yms\" data-start=\"3977\" data-end=\"4004\"\u003eCertified \u003cstrong data-start=\"3989\" data-end=\"4004\"\u003eENERGY STAR\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"3w4hyj\" data-start=\"4005\" data-end=\"4045\"\u003eCertified \u003cstrong data-start=\"4017\" data-end=\"4045\"\u003eENERGY STAR Cold Climate\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4047\" data-end=\"4145\"\u003eThis confirms its suitability for cold climates like those of \u003cstrong data-start=\"4109\" data-end=\"4121\"\u003eMontreal\u003c\/strong\u003e and the \u003cstrong data-start=\"4131\" data-end=\"4144\"\u003eNorth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003chr data-start=\"4147\" data-end=\"4150\"\u003e\n\u003ch2 data-section-id=\"126qj2t\" data-start=\"4152\" data-end=\"4187\"\u003eSound Comfort and Quality of Life\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1p4pyj4\" data-start=\"4189\" data-end=\"4215\"\u003eOptimized Sound Level\u003c\/h3\u003e\n\u003cul data-start=\"4217\" data-end=\"4275\"\u003e\n\u003cli data-section-id=\"bqnfkk\" data-start=\"4217\" data-end=\"4248\"\u003e\u003cstrong data-start=\"4219\" data-end=\"4248\"\u003eIndoor: 34 to 51 dB(A)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"139joiz\" data-start=\"4249\" data-end=\"4275\"\u003e\u003cstrong data-start=\"4251\" data-end=\"4275\"\u003eOutdoor: 60 dB(A)\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"4277\" data-end=\"4486\"\u003eIn a recent installation in \u003cstrong data-start=\"4309\" data-end=\"4325\"\u003eMontreal East\u003c\/strong\u003e, the client immediately noticed the difference from their old system: much quieter operation, especially in continuous heating mode.\u003c\/p\u003e\n\u003chr data-start=\"4488\" data-end=\"4491\"\u003e\n\u003ch2 data-section-id=\"1ut8q54\" data-start=\"4493\" data-end=\"4568\"\u003eCommon Mistakes to Avoid When Choosing an Electric Furnace\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1nqrm2c\" data-start=\"4570\" data-end=\"4604\"\u003eUnderestimating Real Needs\u003c\/h3\u003e\n\u003cp data-start=\"4606\" data-end=\"4723\"\u003eIncorrect sizing remains the most frequent error. A 4-ton unit like this is ideal for:\u003c\/p\u003e\n\u003cul data-start=\"4725\" data-end=\"4816\"\u003e\n\u003cli data-section-id=\"1i8r8p0\" data-start=\"4725\" data-end=\"4742\"\u003eLarge homes\u003c\/li\u003e\n\u003cli data-section-id=\"1wop3rg\" data-start=\"4743\" data-end=\"4760\"\u003eMulti-unit dwellings\u003c\/li\u003e\n\u003cli data-section-id=\"1t7vn8k\" data-start=\"4761\" data-end=\"4816\"\u003eOpen spaces requiring uniform distribution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"181648b\" data-start=\"4818\" data-end=\"4859\"\u003eNeglecting Installation Quality\u003c\/h3\u003e\n\u003cp data-start=\"4861\" data-end=\"5058\"\u003eEven the best equipment loses efficiency if poorly installed. At AirGreen, every installation is carried out by experienced refrigeration technicians, with particular attention to detail:\u003c\/p\u003e\n\u003cul data-start=\"5060\" data-end=\"5152\"\u003e\n\u003cli data-section-id=\"tlqtkz\" data-start=\"5060\" data-end=\"5085\"\u003eDuct sealing\u003c\/li\u003e\n\u003cli data-section-id=\"15r8squ\" data-start=\"5086\" data-end=\"5110\"\u003eSystem balancing\u003c\/li\u003e\n\u003cli data-section-id=\"u2figg\" data-start=\"5111\" data-end=\"5152\"\u003eComplete post-installation verification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5154\" data-end=\"5157\"\u003e\n\u003ch2 data-section-id=\"vzawj5\" data-start=\"5159\" data-end=\"5205\"\u003eField Testimonial: Project Completed in Laval\u003c\/h2\u003e\n\u003cp data-start=\"5207\" data-end=\"5339\"\u003eDuring a project in a triplex in \u003cstrong data-start=\"5242\" data-end=\"5251\"\u003eLaval\u003c\/strong\u003e, we replaced an aging system with this FUJITSU CENTAURI XLTH furnace.\u003c\/p\u003e\n\u003cp data-start=\"5341\" data-end=\"5359\"\u003eChallenges encountered:\u003c\/p\u003e\n\u003cul data-start=\"5361\" data-end=\"5440\"\u003e\n\u003cli data-section-id=\"13lvd3i\" data-start=\"5361\" data-end=\"5394\"\u003ePartially obstructed ducts\u003c\/li\u003e\n\u003cli data-section-id=\"49u757\" data-start=\"5395\" data-end=\"5440\"\u003eUneven air distribution between floors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5442\" data-end=\"5463\"\u003eSolutions provided:\u003c\/p\u003e\n\u003cul data-start=\"5465\" data-end=\"5546\"\u003e\n\u003cli data-section-id=\"1ab8ilc\" data-start=\"5465\" data-end=\"5509\"\u003eComplete cleaning and recalibration of the network\u003c\/li\u003e\n\u003cli data-section-id=\"4rgkin\" data-start=\"5510\" data-end=\"5546\"\u003eAirflow adjustment per zone\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5548\" data-end=\"5558\"\u003eResult:\u003c\/p\u003e\n\u003cul data-start=\"5560\" data-end=\"5698\"\u003e\n\u003cli data-section-id=\"39mcd4\" data-start=\"5560\" data-end=\"5607\"\u003eUniform temperature in all three units\u003c\/li\u003e\n\u003cli data-section-id=\"8apk0u\" data-start=\"5608\" data-end=\"5660\"\u003eSignificant reduction in occupant complaints\u003c\/li\u003e\n\u003cli data-section-id=\"8klala\" data-start=\"5661\" data-end=\"5698\"\u003eStabilized energy consumption\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5700\" data-end=\"5703\"\u003e\n\u003ch2 data-section-id=\"1vpk502\" data-start=\"5705\" data-end=\"5762\"\u003eWhy Choose AirGreen for Your HVAC Installation\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1cyf7w4\" data-start=\"5764\" data-end=\"5793\"\u003eRecognized Local Expertise\u003c\/h3\u003e\n\u003cp data-start=\"5795\" data-end=\"5988\"\u003eWe operate daily in \u003cstrong data-start=\"5830\" data-end=\"5842\"\u003eMontreal\u003c\/strong\u003e, \u003cstrong data-start=\"5844\" data-end=\"5853\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"5855\" data-end=\"5868\"\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong data-start=\"5877\" data-end=\"5890\"\u003eNorth Shore\u003c\/strong\u003e and \u003cstrong data-start=\"5897\" data-end=\"5909\"\u003eSouth Shore\u003c\/strong\u003e, with precise knowledge of climate realities and local standards.\u003c\/p\u003e\n\u003ch3 data-section-id=\"u866co\" data-start=\"5990\" data-end=\"6017\"\u003eTransparency and Rigor\u003c\/h3\u003e\n\u003cul data-start=\"6019\" data-end=\"6144\"\u003e\n\u003cli data-section-id=\"1g2ev7d\" data-start=\"6019\" data-end=\"6059\"\u003eClear prices before work begins\u003c\/li\u003e\n\u003cli data-section-id=\"mdezpx\" data-start=\"6060\" data-end=\"6094\"\u003eNo surprises at project end\u003c\/li\u003e\n\u003cli data-section-id=\"1qjuuqd\" data-start=\"6095\" data-end=\"6144\"\u003eHonest advice based on real data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"fc3ebc\" data-start=\"6146\" data-end=\"6173\"\u003eInsurance and Compliance\u003c\/h3\u003e\n\u003cul data-start=\"6175\" data-end=\"6298\"\u003e\n\u003cli data-section-id=\"lhmimp\" data-start=\"6175\" data-end=\"6195\"\u003eValid RBQ license\u003c\/li\u003e\n\u003cli data-section-id=\"6kicvz\" data-start=\"6196\" data-end=\"6244\"\u003eLiability insurance of $5,000,000\u003c\/li\u003e\n\u003cli data-section-id=\"1lven6r\" data-start=\"6245\" data-end=\"6298\"\u003eStrict adherence to electrical and mechanical standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"6300\" data-end=\"6303\"\u003e\n\u003ch2 data-section-id=\"1tkn08d\" data-start=\"6305\" data-end=\"6376\"\u003eConclusion: A Reliable Solution for Central Heating in Quebec\u003c\/h2\u003e\n\u003cp data-start=\"6378\" data-end=\"6724\"\u003eThe \u003cstrong data-start=\"6381\" data-end=\"6452\"\u003eFUJITSU CENTAURI XLTH R32 4-ton – 48000 BTU electric furnace\u003c\/strong\u003e represents a robust, high-performance option adapted to Quebec's climatic conditions. Its ability to maintain high performance at very low temperatures, combined with solid energy efficiency, makes it a relevant choice for demanding homeowners.\u003c\/p\u003e\n\u003chr data-start=\"6726\" data-end=\"6729\"\u003e\n\u003ch2 data-section-id=\"z8yfww\" data-start=\"6731\" data-end=\"6765\"\u003eTake Action with AirGreen\u003c\/h2\u003e\n\u003cp data-start=\"6767\" data-end=\"7043\"\u003eFor a \u003cstrong data-start=\"6776\" data-end=\"6813\"\u003eprofessional HVAC installation\u003c\/strong\u003e, a personalized evaluation, or a detailed quote, contact our team now. We will assist you in choosing, installing, and maintaining your system to ensure optimal long-term comfort.\u003c\/p\u003e","brand":"Fujitsu","offers":[{"title":"Default Title","offer_id":53410721792292,"sku":"217895718","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/FOURNAISEELECTRIQUEFUJITSUCENTAURIXLTH_a2349326-11b9-4157-90ad-c01defbcce88.png?v=1777634671","url":"https:\/\/airgreen.ca\/en\/products\/fournaise-electrique-fujitsu-centauri-xlth-r32-4-tonnes-48000-btu","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}