{"product_id":"fournaise-electrique-samsung-hylex-premium-r454b-4-tonnes","title":"Electric Furnace SAMSUNG HYLEX PREMIUM R454B | 4 Tons","description":"\u003ch2 data-section-id=\"qmjz30\" data-start=\"80\" data-end=\"157\"\u003eHigh-Efficiency Central HVAC Solution Designed for Quebec Winters\u003c\/h2\u003e\n\u003cp data-start=\"159\" data-end=\"634\"\u003eAt AirGreen, we install central systems designed to meet the climatic realities of \u003cstrong data-start=\"261\" data-end=\"279\"\u003eGreater Montreal\u003c\/strong\u003e, \u003cstrong data-start=\"284\" data-end=\"293\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"298\" data-end=\"311\"\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong data-start=\"319\" data-end=\"332\"\u003eNorth Shore\u003c\/strong\u003e, and the \u003cstrong data-start=\"342\" data-end=\"354\"\u003eSouth Shore\u003c\/strong\u003e. The \u003cstrong data-start=\"359\" data-end=\"422\"\u003eSAMSUNG HYLEX PREMIUM R454B | 4 Ton electric furnace\u003c\/strong\u003e fits this logic: an intelligent combination of a high-performance electric furnace and a central heat pump capable of maintaining constant comfort even during periods of intense cold.\u003c\/p\u003e\n\u003cp data-start=\"636\" data-end=\"924\"\u003eThis model stands out for its advanced integration with the Samsung central heat pump (compatible model \u003cstrong data-start=\"743\" data-end=\"758\"\u003eAC048FCUPCG\u003c\/strong\u003e), its use of the modern refrigerant \u003cstrong data-start=\"800\" data-end=\"810\"\u003eR-454B\u003c\/strong\u003e, as well as its \u003cstrong data-start=\"863\" data-end=\"878\"\u003eENERGY STAR\u003c\/strong\u003e certified energy performance, including cold climate certification.\u003c\/p\u003e\n\u003chr data-start=\"926\" data-end=\"929\"\u003e\n\u003ch2 data-section-id=\"ulcre2\" data-start=\"931\" data-end=\"1006\"\u003eWhy choose the SAMSUNG HYLEX PREMIUM 4 Tons for your property?\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1i6ry8\" data-start=\"1008\" data-end=\"1074\"\u003eThermal performance adapted to Quebec's real conditions\u003c\/h3\u003e\n\u003cp data-start=\"1076\" data-end=\"1191\"\u003eThis system doesn't just work: it maintains stable performance under demanding conditions:\u003c\/p\u003e\n\u003cul data-start=\"1193\" data-end=\"1346\"\u003e\n\u003cli data-section-id=\"1r94wkq\" data-start=\"1193\" data-end=\"1229\"\u003e\u003cstrong data-start=\"1195\" data-end=\"1229\"\u003eNominal capacity: 48,000 BTU\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"ie4p0p\" data-start=\"1230\" data-end=\"1265\"\u003e\u003cstrong data-start=\"1232\" data-end=\"1265\"\u003ePower at -8°C: 30,800 BTU\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"taa23j\" data-start=\"1266\" data-end=\"1302\"\u003e\u003cstrong data-start=\"1268\" data-end=\"1302\"\u003ePower at -15°C: 40,500 BTU\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"13air2h\" data-start=\"1303\" data-end=\"1346\"\u003eEfficient operation down to \u003cstrong data-start=\"1337\" data-end=\"1346\"\u003e-25°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1348\" data-end=\"1583\"\u003eIn several projects carried out by AirGreen in \u003cstrong data-start=\"1395\" data-end=\"1411\"\u003eBoucherville\u003c\/strong\u003e and \u003cstrong data-start=\"1415\" data-end=\"1424\"\u003eLaval\u003c\/strong\u003e, we have observed that this stability prevents short cycling and efficiency losses, a common problem with improperly sized systems.\u003c\/p\u003e\n\u003chr data-start=\"1585\" data-end=\"1588\"\u003e\n\u003ch3 data-section-id=\"l0umzp\" data-start=\"1590\" data-end=\"1645\"\u003eAdvanced energy efficiency and real savings\u003c\/h3\u003e\n\u003cp data-start=\"1647\" data-end=\"1723\"\u003eThe energy performance of this unit is particularly high:\u003c\/p\u003e\n\u003cul data-start=\"1725\" data-end=\"1806\"\u003e\n\u003cli data-section-id=\"24u232\" data-start=\"1725\" data-end=\"1744\"\u003e\u003cstrong data-start=\"1727\" data-end=\"1744\"\u003eSEER2: 16.53\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"lmekyn\" data-start=\"1745\" data-end=\"1763\"\u003e\u003cstrong data-start=\"1747\" data-end=\"1763\"\u003eHSPF2: 8.51\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1ekwzdq\" data-start=\"1764\" data-end=\"1782\"\u003e\u003cstrong data-start=\"1766\" data-end=\"1782\"\u003eEER2: 11.02\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"1yrzc7m\" data-start=\"1783\" data-end=\"1806\"\u003e\u003cstrong data-start=\"1785\" data-end=\"1806\"\u003eCOP at -8°C: 2.06\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1808\" data-end=\"2116\"\u003eThese figures concretely translate into significant reductions in heating and cooling costs. In a recent installation in \u003cstrong data-start=\"1956\" data-end=\"1969\"\u003eLongueuil\u003c\/strong\u003e, a client switched from a classic electric system to this HYLEX model and observed a reduction of over 30% in their winter consumption.\u003c\/p\u003e\n\u003chr data-start=\"2118\" data-end=\"2121\"\u003e\n\u003ch3 data-section-id=\"1hrn5cb\" data-start=\"2123\" data-end=\"2177\"\u003eSmart compatibility with your HVAC system\u003c\/h3\u003e\n\u003cp data-start=\"2179\" data-end=\"2270\"\u003eThis furnace works with a modern \u003cstrong data-start=\"2215\" data-end=\"2250\"\u003eair handling unit (AHU)\u003c\/strong\u003e incorporating:\u003c\/p\u003e\n\u003cul data-start=\"2272\" data-end=\"2443\"\u003e\n\u003cli data-section-id=\"116xs26\" data-start=\"2272\" data-end=\"2318\"\u003e\u003cstrong data-start=\"2274\" data-end=\"2318\"\u003eHigh-efficiency 5-speed ECM motor\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"zeksri\" data-start=\"2319\" data-end=\"2377\"\u003eDynamic airflow control (up to \u003cstrong data-start=\"2364\" data-end=\"2376\"\u003e1207 CFM\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli data-section-id=\"1fmqzu0\" data-start=\"2378\" data-end=\"2443\"\u003eMulti-position configuration (vertical, horizontal, downflow)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2445\" data-end=\"2576\"\u003eThis allows precise adaptation to different types of installations: single-family homes, duplexes, triplexes, or small apartment buildings.\u003c\/p\u003e\n\u003chr data-start=\"2578\" data-end=\"2581\"\u003e\n\u003ch2 data-section-id=\"lxj30a\" data-start=\"2583\" data-end=\"2641\"\u003eProfessional HVAC Installation: The AirGreen Approach\u003c\/h2\u003e\n\u003ch3 data-section-id=\"x5cxsz\" data-start=\"2643\" data-end=\"2681\"\u003eTechnical study before installation\u003c\/h3\u003e\n\u003cp data-start=\"2683\" data-end=\"2777\"\u003eBefore any installation of this \u003cstrong data-start=\"2717\" data-end=\"2749\"\u003eSamsung electric furnace\u003c\/strong\u003e, we always perform:\u003c\/p\u003e\n\u003cul data-start=\"2779\" data-end=\"2972\"\u003e\n\u003cli data-section-id=\"a4uirn\" data-start=\"2779\" data-end=\"2823\"\u003eBuilding thermal load analysis\u003c\/li\u003e\n\u003cli data-section-id=\"5gaiqx\" data-start=\"2824\" data-end=\"2861\"\u003eVerification of existing ducts\u003c\/li\u003e\n\u003cli data-section-id=\"6knjd1\" data-start=\"2862\" data-end=\"2930\"\u003eElectrical compatibility validation (220V, MCA 34A, MOP 40A)\u003c\/li\u003e\n\u003cli data-section-id=\"3x1ov\" data-start=\"2931\" data-end=\"2972\"\u003ePiping inspection (3\/8 – 7\/8)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2974\" data-end=\"3185\"\u003eDuring a project in \u003cstrong data-start=\"2993\" data-end=\"3016\"\u003eMontreal (Rosemont)\u003c\/strong\u003e, we had to adapt the ducts to optimize airflow and avoid pressure losses — a detail often overlooked by less experienced installers.\u003c\/p\u003e\n\u003chr data-start=\"3187\" data-end=\"3190\"\u003e\n\u003ch3 data-section-id=\"3kopnu\" data-start=\"3192\" data-end=\"3238\"\u003eInstallation without compromising quality\u003c\/h3\u003e\n\u003cp data-start=\"3240\" data-end=\"3262\"\u003eOur teams ensure:\u003c\/p\u003e\n\u003cul data-start=\"3264\" data-end=\"3495\"\u003e\n\u003cli data-section-id=\"s8csa8\" data-start=\"3264\" data-end=\"3333\"\u003ePrecise refrigeration connections (copper with aluminum exchanger)\u003c\/li\u003e\n\u003cli data-section-id=\"1xjorp8\" data-start=\"3334\" data-end=\"3379\"\u003eElectronic Expansion Valve (EEV) calibration\u003c\/li\u003e\n\u003cli data-section-id=\"1h6n4om\" data-start=\"3380\" data-end=\"3446\"\u003eComplete commissioning with pressure test and vacuum pull\u003c\/li\u003e\n\u003cli data-section-id=\"t6ix69\" data-start=\"3447\" data-end=\"3495\"\u003eWiFi configuration via \u003cstrong data-start=\"3472\" data-end=\"3495\"\u003eSamsung SmartThings\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3497\" data-end=\"3574\"\u003eThe result: a stable, quiet (\u003cstrong data-start=\"3542\" data-end=\"3561\"\u003e57 dB outdoor\u003c\/strong\u003e) and durable system.\u003c\/p\u003e\n\u003chr data-start=\"3576\" data-end=\"3579\"\u003e\n\u003ch3 data-section-id=\"quouwy\" data-start=\"3581\" data-end=\"3630\"\u003eAvailable subsidies: a concrete advantage\u003c\/h3\u003e\n\u003cp data-start=\"3632\" data-end=\"3686\"\u003eThis model is eligible for a significant subsidy:\u003c\/p\u003e\n\u003cul data-start=\"3688\" data-end=\"3731\"\u003e\n\u003cli data-section-id=\"19bhx6\" data-start=\"3688\" data-end=\"3731\"\u003e\u003cstrong data-start=\"3690\" data-end=\"3731\"\u003eLogisVert Program: up to $3,696\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3733\" data-end=\"3857\"\u003eWe assist our clients throughout the application process to simplify procedures and accelerate reimbursement.\u003c\/p\u003e\n\u003chr data-start=\"3859\" data-end=\"3862\"\u003e\n\u003ch2 data-section-id=\"1v1k7cn\" data-start=\"3864\" data-end=\"3911\"\u003eKey technical features to know\u003c\/h2\u003e\n\u003ch3 data-section-id=\"19zm97v\" data-start=\"3913\" data-end=\"3948\"\u003eRobust and durable construction\u003c\/h3\u003e\n\u003cul data-start=\"3950\" data-end=\"4121\"\u003e\n\u003cli data-section-id=\"1ulsw44\" data-start=\"3950\" data-end=\"4003\"\u003eGalvanized steel cabinet with resistant finish\u003c\/li\u003e\n\u003cli data-section-id=\"15zwfmg\" data-start=\"4004\" data-end=\"4071\"\u003eHigh-density internal insulation (reduced heat loss)\u003c\/li\u003e\n\u003cli data-section-id=\"cfmfw7\" data-start=\"4072\" data-end=\"4121\"\u003eFront access panels for quick maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1k8hv6h\" data-start=\"4123\" data-end=\"4154\"\u003eAdvanced refrigeration system\u003c\/h3\u003e\n\u003cul data-start=\"4156\" data-end=\"4313\"\u003e\n\u003cli data-section-id=\"pr8lnq\" data-start=\"4156\" data-end=\"4198\"\u003eDual rotary BLDC inverter compressor\u003c\/li\u003e\n\u003cli data-section-id=\"1pgjbjk\" data-start=\"4199\" data-end=\"4255\"\u003eRefrigerant \u003cstrong data-start=\"4213\" data-end=\"4223\"\u003eR-454B\u003c\/strong\u003e (more ecological than R-410A)\u003c\/li\u003e\n\u003cli data-section-id=\"8a621y\" data-start=\"4256\" data-end=\"4313\"\u003eIntelligent flow control via electronic expansion valve\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"15mo0nf\" data-start=\"4315\" data-end=\"4351\"\u003eIntelligent drainage management\u003c\/h3\u003e\n\u003cul data-start=\"4353\" data-end=\"4478\"\u003e\n\u003cli data-section-id=\"5oylf2\" data-start=\"4353\" data-end=\"4400\"\u003eAnti-mold \u003cstrong data-start=\"4371\" data-end=\"4384\"\u003eHydrotec™\u003c\/strong\u003e drain pan\u003c\/li\u003e\n\u003cli data-section-id=\"p8uxpb\" data-start=\"4401\" data-end=\"4431\"\u003eIntegrated Microban protection\u003c\/li\u003e\n\u003cli data-section-id=\"cgshed\" data-start=\"4432\" data-end=\"4478\"\u003eDual drainage outlet (left and right)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"4480\" data-end=\"4483\"\u003e\n\u003ch2 data-section-id=\"1im07v6\" data-start=\"4485\" data-end=\"4536\"\u003eReal case: AirGreen installation on the South Shore\u003c\/h2\u003e\n\u003cp data-start=\"4538\" data-end=\"4660\"\u003eIn \u003cstrong data-start=\"4540\" data-end=\"4556\"\u003eSaint-Hubert\u003c\/strong\u003e, we replaced an inefficient old central system with this \u003cstrong data-start=\"4625\" data-end=\"4659\"\u003eSAMSUNG HYLEX PREMIUM 4 Tons\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3 data-section-id=\"142oibu\" data-start=\"4662\" data-end=\"4684\"\u003eChallenges encountered:\u003c\/h3\u003e\n\u003cul data-start=\"4685\" data-end=\"4834\"\u003e\n\u003cli data-section-id=\"1s11s3j\" data-start=\"4685\" data-end=\"4727\"\u003eRestricted space in the mechanical room\u003c\/li\u003e\n\u003cli data-section-id=\"m540ew\" data-start=\"4728\" data-end=\"4783\"\u003eOld system incompatible with new standards\u003c\/li\u003e\n\u003cli data-section-id=\"1kku9im\" data-start=\"4784\" data-end=\"4834\"\u003ePoor air distribution in the bedrooms\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"hf9swx\" data-start=\"4836\" data-end=\"4861\"\u003eSolutions provided:\u003c\/h3\u003e\n\u003cul data-start=\"4862\" data-end=\"5009\"\u003e\n\u003cli data-section-id=\"1cyi9r9\" data-start=\"4862\" data-end=\"4910\"\u003eComplete reorganization of the duct system\u003c\/li\u003e\n\u003cli data-section-id=\"1fq3tce\" data-start=\"4911\" data-end=\"4964\"\u003eOptimized installation with simplified front access\u003c\/li\u003e\n\u003cli data-section-id=\"qnlh03\" data-start=\"4965\" data-end=\"5009\"\u003ePrecise adjustment of ventilation speeds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"1ouc4h8\" data-start=\"5011\" data-end=\"5025\"\u003eResult:\u003c\/h3\u003e\n\u003cul data-start=\"5026\" data-end=\"5163\"\u003e\n\u003cli data-section-id=\"r16kwk\" data-start=\"5026\" data-end=\"5069\"\u003eUniform temperature throughout the house\u003c\/li\u003e\n\u003cli data-section-id=\"1a31wq3\" data-start=\"5070\" data-end=\"5116\"\u003eSignificant reduction in operating noise\u003c\/li\u003e\n\u003cli data-section-id=\"156c86f\" data-start=\"5117\" data-end=\"5163\"\u003eImproved comfort even on -20°C nights\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"5165\" data-end=\"5168\"\u003e\n\u003ch2 data-section-id=\"lun16f\" data-start=\"5170\" data-end=\"5224\"\u003eCommon mistakes to avoid with this type of system\u003c\/h2\u003e\n\u003ch3 data-section-id=\"12jbmkb\" data-start=\"5226\" data-end=\"5253\"\u003eImproper sizing\u003c\/h3\u003e\n\u003cp data-start=\"5255\" data-end=\"5381\"\u003eA 4-ton system must be adapted to the area and insulation. Too powerful or undersized = loss of efficiency.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1tdrnwu\" data-start=\"5383\" data-end=\"5415\"\u003eNon-specialized installation\u003c\/h3\u003e\n\u003cp data-start=\"5417\" data-end=\"5518\"\u003eImproper expansion valve or airflow configuration can reduce performance by up to 25%.\u003c\/p\u003e\n\u003ch3 data-section-id=\"h0e32b\" data-start=\"5520\" data-end=\"5549\"\u003eMaintenance negligence\u003c\/h3\u003e\n\u003cp data-start=\"5551\" data-end=\"5615\"\u003eEven with an advanced system, annual maintenance is essential:\u003c\/p\u003e\n\u003cul data-start=\"5617\" data-end=\"5712\"\u003e\n\u003cli data-section-id=\"10114d7\" data-start=\"5617\" data-end=\"5643\"\u003eCoil cleaning\u003c\/li\u003e\n\u003cli data-section-id=\"9sgacz\" data-start=\"5644\" data-end=\"5672\"\u003eECM motor check\u003c\/li\u003e\n\u003cli data-section-id=\"1vybaq8\" data-start=\"5673\" data-end=\"5712\"\u003eElectrical connection inspection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"5714\" data-end=\"5821\"\u003eAt AirGreen, we offer tailored \u003cstrong data-start=\"5756\" data-end=\"5774\"\u003eHVAC maintenance\u003c\/strong\u003e plans to ensure system longevity.\u003c\/p\u003e\n\u003chr data-start=\"5823\" data-end=\"5826\"\u003e\n\u003ch2 data-section-id=\"1g4msx3\" data-start=\"5828\" data-end=\"5880\"\u003eWhy choose AirGreen for your HVAC project?\u003c\/h2\u003e\n\u003cul data-start=\"5882\" data-end=\"6126\"\u003e\n\u003cli data-section-id=\"1523fds\" data-start=\"5882\" data-end=\"5956\"\u003eRecognized expertise in \u003cstrong data-start=\"5906\" data-end=\"5956\"\u003eHVAC installation in Montreal, Laval, Longueuil\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"sfv08t\" data-start=\"5957\" data-end=\"5996\"\u003eCertified and experienced technicians\u003c\/li\u003e\n\u003cli data-section-id=\"1j7k3a2\" data-start=\"5997\" data-end=\"6027\"\u003eTotal price transparency\u003c\/li\u003e\n\u003cli data-section-id=\"8c5e4f\" data-start=\"6028\" data-end=\"6080\"\u003eCivil liability insurance of \u003cstrong data-start=\"6065\" data-end=\"6080\"\u003e$5,000,000\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli data-section-id=\"5ei5ng\" data-start=\"6081\" data-end=\"6126\"\u003eFull support for subsidies\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6128\" data-end=\"6299\"\u003eWe have installed hundreds of similar central systems in \u003cstrong data-start=\"6202\" data-end=\"6220\"\u003eGreater Montreal\u003c\/strong\u003e, with an approach focused on technical precision and lasting satisfaction.\u003c\/p\u003e\n\u003chr data-start=\"6301\" data-end=\"6304\"\u003e\n\u003ch2 data-section-id=\"4habwe\" data-start=\"6306\" data-end=\"6362\"\u003eConclusion: a reliable, modern, and cost-effective solution\u003c\/h2\u003e\n\u003cp data-start=\"6364\" data-end=\"6499\"\u003eThe \u003cstrong data-start=\"6367\" data-end=\"6430\"\u003eSAMSUNG HYLEX PREMIUM R454B | 4 Ton electric furnace\u003c\/strong\u003e represents a strategic choice for homeowners seeking:\u003c\/p\u003e\n\u003cul data-start=\"6501\" data-end=\"6664\"\u003e\n\u003cli data-section-id=\"102s0dc\" data-start=\"6501\" data-end=\"6541\"\u003eStable performance in cold climates\u003c\/li\u003e\n\u003cli data-section-id=\"sxly9j\" data-start=\"6542\" data-end=\"6577\"\u003eHigh energy efficiency\u003c\/li\u003e\n\u003cli data-section-id=\"119z23u\" data-start=\"6578\" data-end=\"6628\"\u003eCompatibility with modern technologies\u003c\/li\u003e\n\u003cli data-section-id=\"1p6wlvr\" data-start=\"6629\" data-end=\"6664\"\u003eConstant comfort all year round\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"6666\" data-end=\"6807\"\u003eCombined with professional AirGreen installation, it becomes a complete, durable, and optimized solution for Quebec's realities.\u003c\/p\u003e\n\u003chr data-start=\"6809\" data-end=\"6812\"\u003e\n\u003ch2 data-section-id=\"z8yfww\" data-start=\"6814\" data-end=\"6848\"\u003eTake action with AirGreen\u003c\/h2\u003e\n\u003cp data-start=\"6850\" data-end=\"7115\"\u003eFor \u003cstrong data-start=\"6859\" data-end=\"6896\"\u003eprofessional HVAC installation\u003c\/strong\u003e, a detailed quote, or personalized advice, contact AirGreen today. Our experts are available to assist you with your project in \u003cstrong data-start=\"7061\" data-end=\"7114\"\u003eMontreal, Laval, Longueuil, the North Shore, and the South Shore\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Samsung","offers":[{"title":"Default Title","offer_id":53420685230372,"sku":"218158148","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SAMSUNG-FOURNAISEELECTRIQUEHYLEXPREMIUM_9a7d6801-e85b-408f-bd24-9ec5b30642bb.png?v=1777634480","url":"https:\/\/airgreen.ca\/en\/products\/fournaise-electrique-samsung-hylex-premium-r454b-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}