{"product_id":"gainable-gree-x-match-r32-36000-btu-montreal-laval-rive-sud","title":"GREE X-Match R32 Ducted | 36000 BTU | Montréal, Laval, South Shore","description":"\u003ch2\u003e1,324 cu. ft.\/min: the unit that supplies an entire duct network\u003c\/h2\u003e\u003cp\u003eThe \u003cstrong\u003e36,000 BTU GREE X-Match R32\u003c\/strong\u003e moves \u003cstrong\u003e1,324 cu. ft.\/min\u003c\/strong\u003e of air. By far the highest airflow of all the \u003cstrong\u003eR-32 ducted units\u003c\/strong\u003e we install, this figure - much more than the BTU capacity - defines what the unit can do: supply a \u003cstrong\u003educt network\u003c\/strong\u003e serving six to eight grilles across two levels from a single unit.\u003c\/p\u003e\u003cp\u003eThere is a second, more practical reason why this model often appears in renovation projects: the indoor unit is only \u003cstrong\u003e10.24 inches high\u003c\/strong\u003e. It is slimmer than all the other ducted units in the range, despite having a much higher capacity. In a basement ceiling void where every inch counts, this dimension can sometimes determine the project's feasibility on its own.\u003c\/p\u003e\u003ch3\u003eCertified figures\u003c\/h3\u003e\u003cp\u003eAHRI Certificate 215414346, ENERGY STAR listing 4514325.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2 of 20.0\u003c\/strong\u003e and \u003cstrong\u003eEER2 of 11.95\u003c\/strong\u003e in cooling\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2 of 8.5\u003c\/strong\u003e in heating\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-8 °C\u003c\/strong\u003e: 23,400 BTU\/h, COP of 2.87\u003c\/li\u003e\n\u003cli\u003eAt \u003cstrong\u003e-15 °C\u003c\/strong\u003e: 23,800 BTU\/h, COP of 1.9\u003c\/li\u003e\n\u003cli\u003eDown to \u003cstrong\u003e-25 °C\u003c\/strong\u003e: 19,800 BTU\/h, COP of 1.0\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch4\u003eThree things we point out rather than keep quiet\u003c\/h4\u003e\u003cp\u003e\u003cstrong\u003eThe certification stops at -25 °C.\u003c\/strong\u003e This model is ENERGY STAR certified but \u003cstrong\u003edoes not have the cold-climate designation\u003c\/strong\u003e. No performance is certified below -25 °C, so we will not claim any.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThe COP at -25 °C is 1.0.\u003c\/strong\u003e At that precise temperature, the unit delivers one kilowatt-hour of heat per kilowatt-hour consumed - the efficiency of an electric baseboard heater. It continues to operate and provide 19,800 BTU\/h, which remains useful, but the savings disappear during those hours. In a Montreal winter, they number in the dozens; in Lanaudière or the Laurentians, they have a greater impact, and we take that into account in our recommendation.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIts capacity at -8 °C is lower than that of the 30,000 BTU model\u003c\/strong\u003e (23,400 versus 24,000), while its own capacity at -15 °C is higher. These are the certificate values exactly as stated. If your primary need is heating rather than air distribution, the 30,000 BTU model deserves serious comparison.\u003c\/p\u003e\u003ch3\u003eWhat makes this model the right choice\u003c\/h3\u003e\u003cp\u003eA large single-storey home, a cottage where one unit must serve two floors, a commercial space, or a fully finished basement with several enclosed rooms. Wherever the challenge is to \u003cem\u003edistribute\u003c\/em\u003e air rather than produce more of it, this model has an advantage that capacity alone does not explain.\u003c\/p\u003e\u003cp\u003eIt also removes \u003cstrong\u003e7.82 pints of water per hour\u003c\/strong\u003e, the best dehumidification performance in the range. In a basement or large space, this can effectively replace one or two portable dehumidifiers, with no floor unit or tank to empty.\u003c\/p\u003e\u003ch3\u003eThe duct network becomes the project\u003c\/h3\u003e\u003cp\u003eAt 1,324 cu. ft.\/min, the network is no longer an accessory to the unit: it is half the work. Generously sized main sections, large-radius elbows, balanced branches, and, above all, a return sized for the airflow. An undersized return is the defect we encounter most often on large ducted systems installed elsewhere: the unit struggles, the actual airflow never reaches its rated value, and duct noise sets in.\u003c\/p\u003e\u003cp\u003eWe calculate the network's pressure drop before installation. It is a step that cannot be corrected afterward.\u003c\/p\u003e\u003ch3\u003eAcoustics\u003c\/h3\u003e\u003cp\u003eIndoor unit: \u003cstrong\u003e38 to 43 dB(A)\u003c\/strong\u003e. The difference between the minimum and maximum is the narrowest in the range, but the floor is high: this is not a unit to install directly above a bedroom without acoustic treatment. Technical room, corridor ceiling, or basement ceiling void, with insulation on the first duct section. Outdoor unit: \u003cstrong\u003e62 dB(A)\u003c\/strong\u003e.\u003c\/p\u003e\u003ch3\u003eInstallation data\u003c\/h3\u003e\u003cp\u003eIndoor unit: \u003cstrong\u003e52.76 x 25.79 x 10.24 inches\u003c\/strong\u003e. The unit is long, which is the trade-off for its slimness - plan for continuous linear clearance rather than a square enclosure. Outdoor unit: \u003cstrong\u003e39.38 x 16.81 x 29.38 inches\u003c\/strong\u003e. Connection: \u003cstrong\u003e1\/4 - 5\/8 inch\u003c\/strong\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003e220 V\u003c\/strong\u003e power supply, \u003cstrong\u003e23 A MCA\u003c\/strong\u003e and \u003cstrong\u003e35 A MOP\u003c\/strong\u003e, values taken from the outdoor unit. A 35 A circuit requires a serious panel check: we assess this before preparing a quote, and if an upgrade to 200 A is necessary, it is included in the estimate.\u003c\/p\u003e\u003cp\u003eA note about the dimensions: GREE's specification sheet publishes an inch column for this model that actually corresponds to the outdoor cabinet. The indoor dimensions above are converted from the manufacturer's millimetres, which are consistent, and match those of the equivalent ducted unit already listed on our website.\u003c\/p\u003e\u003ch3\u003eFinancial assistance\u003c\/h3\u003e\u003cp\u003eEligible for Hydro-Québec's \u003cstrong\u003eLogisVert\u003c\/strong\u003e program for \u003cstrong\u003e$1,170\u003c\/strong\u003e for an owner of an existing home. The absence of the cold-climate designation excludes the program's bonus. We verify the amount using Hydro-Québec's official tool when preparing the application.\u003c\/p\u003e\u003ch3\u003eOur service area\u003c\/h3\u003e\u003cp\u003eWe install in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. A unit of this size necessarily requires a technical visit before pricing.\u003c\/p\u003e\u003ch2\u003eRequest your quote\u003c\/h2\u003e\u003cp\u003eSend us the floor plan for the levels to be served, the available ceiling void height, and a photo of your electrical panel's rating plate. We will get back to you with a load calculation, a duct layout sized for the airflow, an electrical feasibility assessment, and an installed price.\u003c\/p\u003e","brand":"Gree","offers":[{"title":"Default Title","offer_id":56294068453668,"sku":null,"price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_GAINABLE_GREE_X_MATCH_R32_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_2701c1d4-d255-4b0e-9b82-505a1012b990.png?v=1789520446","url":"https:\/\/airgreen.ca\/en\/products\/gainable-gree-x-match-r32-36000-btu-montreal-laval-rive-sud","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}