{"product_id":"lg-plafonnier-de-type-cassette-2x2-18-000-btu","title":"LG: 2x2 Cassette Type Ceiling Mounted | 18,000 BTU","description":"\u003ch2 data-section-id=\"29dqnv\" data-start=\"70\" data-end=\"150\"\u003eA Discreet 2x2 Cassette for Heating and Air Conditioning Without Sacrificing Wall Space\u003c\/h2\u003e\n\u003cp data-start=\"152\" data-end=\"847\"\u003eThe \u003cstrong data-start=\"155\" data-end=\"204\"\u003eLG 18,000 BTU 2x2 cassette ceiling unit\u003c\/strong\u003e addresses a very specific need we often encounter at AirGreen: efficiently air conditioning and heating an open-plan room, commercial space, office, conference room, boutique, or high-end residential area where a wall unit is not ideal. In many buildings in \u003cstrong data-start=\"511\" data-end=\"523\"\u003eMontreal\u003c\/strong\u003e, \u003cstrong data-start=\"525\" data-end=\"534\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"536\" data-end=\"549\"\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong data-start=\"557\" data-end=\"570\"\u003eNorth Shore\u003c\/strong\u003e, and the \u003cstrong data-start=\"580\" data-end=\"592\"\u003eSouth Shore\u003c\/strong\u003e, walls are already occupied by display cases, cabinets, shelves, bookshelves, full-height windows, or architectural features. In these cases, a ceiling-recessed cassette becomes a much more coherent HVAC solution.\u003c\/p\u003e\n\u003cp data-start=\"849\" data-end=\"1489\"\u003eThis LG model, consisting of the indoor unit \u003cstrong data-start=\"893\" data-end=\"906\"\u003eKNUDB181A\u003c\/strong\u003e and the outdoor unit \u003cstrong data-start=\"932\" data-end=\"945\"\u003eKUSXB181A\u003c\/strong\u003e, offers a nominal cooling capacity of \u003cstrong data-start=\"997\" data-end=\"1011\"\u003e18,000 BTU\u003c\/strong\u003e and a published nominal heating capacity of \u003cstrong data-start=\"1061\" data-end=\"1075\"\u003e20,000 BTU\u003c\/strong\u003e under reference conditions. It operates with \u003cstrong data-start=\"1144\" data-end=\"1152\"\u003eR-32\u003c\/strong\u003e refrigerant, is \u003cstrong data-start=\"1167\" data-end=\"1183\"\u003eENERGY STAR®\u003c\/strong\u003e certified and \u003cstrong data-start=\"1187\" data-end=\"1216\"\u003eENERGY STAR® Cold Climate\u003c\/strong\u003e, and is listed on the AirGreen sheet with AHRI \u003cstrong data-start=\"1262\" data-end=\"1275\"\u003e214825953\u003c\/strong\u003e. The provincial \u003cstrong data-start=\"1303\" data-end=\"1316\"\u003eLogisVert\u003c\/strong\u003e subsidy indicated on our product sheet is \u003cstrong data-start=\"1357\" data-end=\"1368\"\u003e$1,560\u003c\/strong\u003e, as updated on \u003cstrong data-start=\"1394\" data-end=\"1414\"\u003eNovember 26, 2025\u003c\/strong\u003e, subject to eligibility validation at the time of submission.\u003c\/p\u003e\n\u003cp data-start=\"1491\" data-end=\"1789\"\u003eThe technical data below cross-references the AirGreen sheet and the LG R32 Single-Zone Four-Way Cassette engineering manual, particularly the sections on \u003cstrong data-start=\"1657\" data-end=\"1682\"\u003eKNUDB181A \/ KUSXB181A\u003c\/strong\u003e pairing, capacities, sound levels, options, electricity, drainage, and piping limits.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1t034uu\" data-start=\"1791\" data-end=\"1851\"\u003eWhy choose a cassette over a wall unit\u003c\/h3\u003e\n\u003cp data-start=\"1853\" data-end=\"2301\"\u003eA \u003cstrong data-start=\"1857\" data-end=\"1879\"\u003ewall-mounted heat pump\u003c\/strong\u003e remains an excellent choice in many homes. However, a \u003cstrong data-start=\"1948\" data-end=\"1985\"\u003eceiling-recessed 2x2 cassette\u003c\/strong\u003e offers a major advantage: it distributes air in four directions from a central point. This reduces uncomfortable zones, especially in rooms where occupants move around, where workstations are spread across multiple sides, or where air blown directly from a wall would be poorly received.\u003c\/p\u003e\n\u003cp data-start=\"2303\" data-end=\"2391\"\u003eAt AirGreen, we often recommend this type of unit in the following situations:\u003c\/p\u003e\n\u003cul data-start=\"2393\" data-end=\"3011\"\u003e\n\u003cli data-section-id=\"1swrcsi\" data-start=\"2393\" data-end=\"2473\"\u003e\n\u003cstrong data-start=\"2395\" data-end=\"2432\"\u003eProfessional offices in Montreal\u003c\/strong\u003e with suspended ceilings and open-plan areas.\u003c\/li\u003e\n\u003cli data-section-id=\"qpisx1\" data-start=\"2474\" data-end=\"2548\"\u003e\n\u003cstrong data-start=\"2476\" data-end=\"2497\"\u003eBusinesses in Laval\u003c\/strong\u003e where walls are used for displays or signage.\u003c\/li\u003e\n\u003cli data-section-id=\"2wxyzw\" data-start=\"2549\" data-end=\"2672\"\u003e\n\u003cstrong data-start=\"2551\" data-end=\"2613\"\u003eWaiting rooms, clinics, studios, and service premises\u003c\/strong\u003e where acoustic comfort is as important as performance.\u003c\/li\u003e\n\u003cli data-section-id=\"1teeed8\" data-start=\"2673\" data-end=\"2760\"\u003e\n\u003cstrong data-start=\"2675\" data-end=\"2714\"\u003eHigh-end condos and renovations\u003c\/strong\u003e where the interior appearance must remain clean.\u003c\/li\u003e\n\u003cli data-section-id=\"s8jr8n\" data-start=\"2761\" data-end=\"2891\"\u003e\n\u003cstrong data-start=\"2763\" data-end=\"2807\"\u003eSpaces on the South Shore and in Montérégie\u003c\/strong\u003e requiring more uniform air distribution than with a standard wall unit.\u003c\/li\u003e\n\u003cli data-section-id=\"8l1v0v\" data-start=\"2892\" data-end=\"3011\"\u003e\n\u003cstrong data-start=\"2894\" data-end=\"2927\"\u003eResidential open areas\u003c\/strong\u003e where the living room, dining room, and kitchen communicate without full separation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"3013\" data-end=\"3457\"\u003eThe indoor unit is designed with \u003cstrong data-start=\"3048\" data-end=\"3072\"\u003efour air outlets\u003c\/strong\u003e and a central return inlet. Motorized vanes allow for adjustment of the airflow direction to avoid a cold draft directly on a table, counter, workstation, or sofa. In a commercial space, this detail makes a real difference: comfort depends not only on the BTU count but also on how the air reaches the occupants.\u003c\/p\u003e\n\u003ch3 data-section-id=\"nqm1j5\" data-start=\"3459\" data-end=\"3508\"\u003eLG 2x2 18,000 BTU Cassette Technical Data Sheet\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"3510\" data-end=\"5008\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"3510\" data-end=\"3530\"\u003e\n\u003ctr data-start=\"3510\" data-end=\"3530\"\u003e\n\u003cth data-start=\"3510\" data-end=\"3520\" data-col-size=\"md\" class=\"\"\u003eItem\u003c\/th\u003e\n\u003cth data-start=\"3520\" data-end=\"3530\" data-col-size=\"md\" class=\"\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"3541\" data-end=\"5008\"\u003e\n\u003ctr data-start=\"3541\" data-end=\"3560\"\u003e\n\u003ctd data-start=\"3541\" data-end=\"3550\" data-col-size=\"md\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"3550\" data-end=\"3560\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"3552\" data-end=\"3558\"\u003eLG\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3561\" data-end=\"3620\"\u003e\n\u003ctd data-start=\"3561\" data-end=\"3568\" data-col-size=\"md\"\u003eType\u003c\/td\u003e\n\u003ctd data-start=\"3568\" data-end=\"3620\" data-col-size=\"md\"\u003e\n\u003cstrong data-start=\"3570\" data-end=\"3597\"\u003e2x2 Cassette Ceiling\u003c\/strong\u003e, single zone system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3621\" data-end=\"3657\"\u003e\n\u003ctd data-start=\"3621\" data-end=\"3640\" data-col-size=\"md\"\u003eIndoor Unit\u003c\/td\u003e\n\u003ctd data-start=\"3640\" data-end=\"3657\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"3642\" data-end=\"3655\"\u003eKNUDB181A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3658\" data-end=\"3694\"\u003e\n\u003ctd data-start=\"3658\" data-end=\"3677\" data-col-size=\"md\"\u003eOutdoor Unit\u003c\/td\u003e\n\u003ctd data-start=\"3677\" data-end=\"3694\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"3679\" data-end=\"3692\"\u003eKUSXB181A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3695\" data-end=\"3752\"\u003e\n\u003ctd data-start=\"3695\" data-end=\"3734\" data-col-size=\"md\"\u003eNominal Cooling Capacity\u003c\/td\u003e\n\u003ctd data-start=\"3734\" data-end=\"3752\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"3736\" data-end=\"3750\"\u003e18,000 BTU\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3753\" data-end=\"3839\"\u003e\n\u003ctd data-start=\"3753\" data-end=\"3804\" data-col-size=\"md\"\u003eMin \/ Nominal \/ Max Cooling Capacity\u003c\/td\u003e\n\u003ctd data-start=\"3804\" data-end=\"3839\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"3806\" data-end=\"3837\"\u003e7,200 ~ 18,000 ~ 23,000 BTU\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3840\" data-end=\"3920\"\u003e\n\u003ctd data-start=\"3840\" data-end=\"3885\" data-col-size=\"md\"\u003eMin \/ Nominal \/ Max Heating Capacity\u003c\/td\u003e\n\u003ctd data-start=\"3885\" data-end=\"3920\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"3887\" data-end=\"3918\"\u003e7,000 ~ 20,000 ~ 24,000 BTU\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3921\" data-end=\"4034\"\u003e\n\u003ctd data-start=\"3921\" data-end=\"3965\" data-col-size=\"md\"\u003eLow Temperature Heating Capacity\u003c\/td\u003e\n\u003ctd data-start=\"3965\" data-end=\"4034\" data-col-size=\"md\"\u003e\n\u003cstrong data-start=\"3967\" data-end=\"3997\"\u003e13,000 BTU at approximately -8 °C\u003c\/strong\u003e, depending on reference conditions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4035\" data-end=\"4098\"\u003e\n\u003ctd data-start=\"4035\" data-end=\"4080\" data-col-size=\"md\"\u003eMaximum Published Capacity at approx. -15 °C\u003c\/td\u003e\n\u003ctd data-start=\"4080\" data-end=\"4098\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"4082\" data-end=\"4096\"\u003e19,000 BTU\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4099\" data-end=\"4125\"\u003e\n\u003ctd data-start=\"4099\" data-end=\"4113\" data-col-size=\"md\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd data-start=\"4113\" data-end=\"4125\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"4115\" data-end=\"4123\"\u003eR-32\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4126\" data-end=\"4195\"\u003e\n\u003ctd data-start=\"4126\" data-end=\"4142\" data-col-size=\"md\"\u003eCertification\u003c\/td\u003e\n\u003ctd data-start=\"4142\" data-end=\"4195\" data-col-size=\"md\"\u003e\n\u003cstrong data-start=\"4144\" data-end=\"4160\"\u003eENERGY STAR®\u003c\/strong\u003e and \u003cstrong data-start=\"4164\" data-end=\"4193\"\u003eENERGY STAR® Cold Climate\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4196\" data-end=\"4216\"\u003e\n\u003ctd data-start=\"4196\" data-end=\"4204\" data-col-size=\"md\"\u003eSEER2\u003c\/td\u003e\n\u003ctd data-start=\"4204\" data-end=\"4216\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"4206\" data-end=\"4214\"\u003e20.5\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4217\" data-end=\"4236\"\u003e\n\u003ctd data-start=\"4217\" data-end=\"4225\" data-col-size=\"md\"\u003eHSPF2\u003c\/td\u003e\n\u003ctd data-start=\"4225\" data-end=\"4236\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"4227\" data-end=\"4234\"\u003e9.5\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4237\" data-end=\"4256\"\u003e\n\u003ctd data-start=\"4237\" data-end=\"4244\" data-col-size=\"md\"\u003eEER2\u003c\/td\u003e\n\u003ctd data-start=\"4244\" data-end=\"4256\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"4246\" data-end=\"4254\"\u003e13.0\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4257\" data-end=\"4293\"\u003e\n\u003ctd data-start=\"4257\" data-end=\"4277\" data-col-size=\"md\"\u003eDehumidification\u003c\/td\u003e\n\u003ctd data-start=\"4277\" data-end=\"4293\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"4279\" data-end=\"4291\"\u003e3.1 pt\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4294\" data-end=\"4358\"\u003e\n\u003ctd data-start=\"4294\" data-end=\"4320\" data-col-size=\"md\"\u003eIndoor Sound Level\u003c\/td\u003e\n\u003ctd data-start=\"4320\" data-end=\"4358\" data-col-size=\"md\"\u003e\n\u003cstrong data-start=\"4322\" data-end=\"4339\"\u003e36 to 41 dB(A)\u003c\/strong\u003e depending on speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4359\" data-end=\"4422\"\u003e\n\u003ctd data-start=\"4359\" data-end=\"4385\" data-col-size=\"md\"\u003eOutdoor Sound Level\u003c\/td\u003e\n\u003ctd data-start=\"4385\" data-end=\"4422\" data-col-size=\"md\"\u003eUp to \u003cstrong data-start=\"4395\" data-end=\"4407\"\u003e52 dB(A)\u003c\/strong\u003e in heating mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4423\" data-end=\"4491\"\u003e\n\u003ctd data-start=\"4423\" data-end=\"4447\" data-col-size=\"md\"\u003eIndoor Airflow\u003c\/td\u003e\n\u003ctd data-start=\"4447\" data-end=\"4491\" data-col-size=\"md\"\u003e\n\u003cstrong data-start=\"4449\" data-end=\"4472\"\u003e459 \/ 424 \/ 388 CFM\u003c\/strong\u003e depending on speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4492\" data-end=\"4557\"\u003e\n\u003ctd data-start=\"4492\" data-end=\"4517\" data-col-size=\"md\"\u003eIndoor Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"4517\" data-end=\"4557\" data-col-size=\"md\"\u003eApproximately \u003cstrong data-start=\"4527\" data-end=\"4555\"\u003e22.44 x 22.44 x 10.09 in\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4558\" data-end=\"4620\"\u003e\n\u003ctd data-start=\"4558\" data-end=\"4583\" data-col-size=\"md\"\u003eOutdoor Dimensions\u003c\/td\u003e\n\u003ctd data-start=\"4583\" data-end=\"4620\" data-col-size=\"md\"\u003eApproximately \u003cstrong data-start=\"4593\" data-end=\"4618\"\u003e37.41 x 13 x 32.84 in\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4621\" data-end=\"4666\"\u003e\n\u003ctd data-start=\"4621\" data-end=\"4631\" data-col-size=\"md\"\u003eVoltage\u003c\/td\u003e\n\u003ctd data-start=\"4631\" data-end=\"4666\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"4633\" data-end=\"4664\"\u003e208-230 V \/ 60 Hz \/ 1 phase\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4667\" data-end=\"4685\"\u003e\n\u003ctd data-start=\"4667\" data-end=\"4673\" data-col-size=\"md\"\u003eMCA\u003c\/td\u003e\n\u003ctd data-start=\"4673\" data-end=\"4685\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"4675\" data-end=\"4683\"\u003e16 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4686\" data-end=\"4704\"\u003e\n\u003ctd data-start=\"4686\" data-end=\"4692\" data-col-size=\"md\"\u003eMOP\u003c\/td\u003e\n\u003ctd data-start=\"4692\" data-end=\"4704\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"4694\" data-end=\"4702\"\u003e25 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4705\" data-end=\"4765\"\u003e\n\u003ctd data-start=\"4705\" data-end=\"4727\" data-col-size=\"md\"\u003eRecommended Piping\u003c\/td\u003e\n\u003ctd data-start=\"4727\" data-end=\"4765\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"4729\" data-end=\"4763\"\u003e1\/4 inch liquid \/ 1\/2 inch vapor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4766\" data-end=\"4853\"\u003e\n\u003ctd data-start=\"4766\" data-end=\"4803\" data-col-size=\"md\"\u003eEquivalent Piping Length\u003c\/td\u003e\n\u003ctd data-start=\"4803\" data-end=\"4853\" data-col-size=\"md\"\u003e\n\u003cstrong data-start=\"4805\" data-end=\"4822\"\u003e16.4 to 164 ft\u003c\/strong\u003e depending on system limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4854\" data-end=\"4902\"\u003e\n\u003ctd data-start=\"4854\" data-end=\"4862\" data-col-size=\"md\"\u003eWi-Fi\u003c\/td\u003e\n\u003ctd data-start=\"4862\" data-end=\"4902\" data-col-size=\"md\"\u003e\n\u003cstrong data-start=\"4864\" data-end=\"4877\"\u003eOptional\u003c\/strong\u003e with compatible module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"4903\" data-end=\"5008\"\u003e\n\u003ctd data-start=\"4903\" data-end=\"4914\" data-col-size=\"md\"\u003eWarranty\u003c\/td\u003e\n\u003ctd data-start=\"4914\" data-end=\"5008\" data-col-size=\"md\"\u003e\n\u003cstrong data-start=\"4916\" data-end=\"4972\"\u003e10 years compressor, 10 years parts, 0 years labor\u003c\/strong\u003e, extended warranty possible\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"5010\" data-end=\"5388\"\u003eThis table provides a clear overview of the system, but it does not replace a complete on-site evaluation. A successful \u003cstrong data-start=\"5120\" data-end=\"5141\"\u003eHVAC installation\u003c\/strong\u003e depends on the actual heat load, insulation, ceiling height, sun exposure, type of glazing, ambient noise, ceiling access, refrigerant piping route, and condensate drainage.\u003c\/p\u003e\n\u003ch3 data-section-id=\"dy9spn\" data-start=\"5390\" data-end=\"5440\"\u003eWhat 18,000 BTU means in a real space\u003c\/h3\u003e\n\u003cp data-start=\"5442\" data-end=\"6081\"\u003eThe figure \u003cstrong data-start=\"5453\" data-end=\"5467\"\u003e18,000 BTU\u003c\/strong\u003e often attracts attention, but it needs to be interpreted precisely. In a well-insulated interior office, 18,000 BTU can be suitable for a larger area than in a south-facing glazed commercial space. In a corner unit in \u003cstrong data-start=\"5705\" data-end=\"5718\"\u003eLongueuil\u003c\/strong\u003e, for example, a sun-exposed storefront, a frequently opening door, and a higher ceiling can significantly increase cooling demand. Conversely, in a closed, well-insulated space with little solar gain, the same equipment can operate more gently and for longer, promoting better temperature stability.\u003c\/p\u003e\n\u003cp data-start=\"6083\" data-end=\"6515\"\u003eWe have often observed that clients first shop for BTU capacity, then realize that the real issue is air distribution. A wall unit of equivalent capacity can very well heat or cool a nearby area, but leave a corner less comfortable. The \u003cstrong data-start=\"6365\" data-end=\"6384\"\u003eLG 2x2 cassette\u003c\/strong\u003e has an advantage here: its four-way airflow better covers open spaces and reduces the feeling of concentrated drafts.\u003c\/p\u003e\n\u003cp data-start=\"6517\" data-end=\"6920\"\u003eFor a neighborhood business in \u003cstrong data-start=\"6548\" data-end=\"6560\"\u003eMontreal\u003c\/strong\u003e, a ceiling-mounted cassette often frees up wall space for shelves or displays. For an office in \u003cstrong data-start=\"6683\" data-end=\"6692\"\u003eLaval\u003c\/strong\u003e, it can prevent an employee sitting directly under a wall unit from continuously receiving cold air. For a renovation on the \u003cstrong data-start=\"6824\" data-end=\"6836\"\u003eSouth Shore\u003c\/strong\u003e, it can be integrated into a suspended ceiling without altering the aesthetic of the walls.\u003c\/p\u003e\n\u003ch2 data-section-id=\"eu6dcv\" data-start=\"6922\" data-end=\"7007\"\u003eInstallation, Winter Performance, and AirGreen Service: The Details That Matter\u003c\/h2\u003e\n\u003ch3 data-section-id=\"k8dfyp\" data-start=\"7009\" data-end=\"7064\"\u003eA Heat Pump Adapted to the Greater Montreal Climate\u003c\/h3\u003e\n\u003cp data-start=\"7066\" data-end=\"7470\"\u003eThe \u003cstrong data-start=\"7076\" data-end=\"7101\"\u003eKNUDB181A \/ KUSXB181A\u003c\/strong\u003e model is designed to operate in heating mode down to approximately \u003cstrong data-start=\"7158\" data-end=\"7168\"\u003e-20 °C\u003c\/strong\u003e, an essential feature for a \u003cstrong data-start=\"7211\" data-end=\"7237\"\u003eheat pump in Montreal\u003c\/strong\u003e, \u003cstrong data-start=\"7241\" data-end=\"7250\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"7254\" data-end=\"7267\"\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong data-start=\"7276\" data-end=\"7289\"\u003eNorth Shore\u003c\/strong\u003e, or on the \u003cstrong data-start=\"7300\" data-end=\"7312\"\u003eSouth Shore\u003c\/strong\u003e. The \u003cstrong data-start=\"7325\" data-end=\"7354\"\u003eENERGY STAR® Cold Climate\u003c\/strong\u003e designation confirms that this system has been rated for more demanding winter conditions than those of a temperate climate.\u003c\/p\u003e\n\u003cp data-start=\"7472\" data-end=\"7983\"\u003eThat said, an 18,000 BTU cassette does not automatically replace all existing heating systems in all buildings. In an old duplex in Montreal with air infiltration, poorly insulated walls, and large windows, we must calculate heat losses before recommending the device as a primary or supplementary source. In a renovated commercial space with a more efficient envelope, the same model can offer very stable comfort, especially when airflow is well planned.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1rbiohs\" data-start=\"7985\" data-end=\"8056\"\u003eR-32: Efficiency, Precautions, and Professional Responsibility\u003c\/h3\u003e\n\u003cp data-start=\"8058\" data-end=\"8436\"\u003eThe \u003cstrong data-start=\"8061\" data-end=\"8081\"\u003eR-32 refrigerant\u003c\/strong\u003e is increasingly present in recent HVAC equipment. It offers better energy performance than several older generations of refrigerants and has zero ozone depletion potential. However, it remains a mildly flammable refrigerant, which requires installation by qualified professionals.\u003c\/p\u003e\n\u003cp data-start=\"8438\" data-end=\"8577\"\u003eThis is where the choice of contractor becomes crucial. At AirGreen, we pay particular attention to the following steps:\u003c\/p\u003e\n\u003cul data-start=\"8579\" data-end=\"8963\"\u003e\n\u003cli data-section-id=\"1ro82og\" data-start=\"8579\" data-end=\"8638\"\u003eVerification of piping route before work.\u003c\/li\u003e\n\u003cli data-section-id=\"23q6ss\" data-start=\"8639\" data-end=\"8690\"\u003eCompliance with diameters and lengths permitted by LG.\u003c\/li\u003e\n\u003cli data-section-id=\"725s9m\" data-start=\"8691\" data-end=\"8759\"\u003eBrazing, flaring, or connection according to appropriate methods.\u003c\/li\u003e\n\u003cli data-section-id=\"x95qnd\" data-start=\"8760\" data-end=\"8780\"\u003eLeak test.\u003c\/li\u003e\n\u003cli data-section-id=\"snsy5o\" data-start=\"8781\" data-end=\"8806\"\u003eComplete vacuum evacuation.\u003c\/li\u003e\n\u003cli data-section-id=\"3880bf\" data-start=\"8807\" data-end=\"8850\"\u003eAdditional charge calculation if necessary.\u003c\/li\u003e\n\u003cli data-section-id=\"1x88ayj\" data-start=\"8851\" data-end=\"8893\"\u003eCondensate drainage verification.\u003c\/li\u003e\n\u003cli data-section-id=\"1ylb87i\" data-start=\"8894\" data-end=\"8963\"\u003eCommissioning and validation of heating and cooling modes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"8965\" data-end=\"9205\"\u003eThe LG single-zone cassette also integrates a \u003cstrong data-start=\"9013\" data-end=\"9050\"\u003erefrigerant leak detector\u003c\/strong\u003e, an important feature in a ceiling-recessed unit. This never replaces a compliant installation but adds a useful level of monitoring.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1gvgwv0\" data-start=\"9207\" data-end=\"9267\"\u003eWhat we check before installing a 2x2 cassette\u003c\/h3\u003e\n\u003cp data-start=\"9269\" data-end=\"9486\"\u003eA recessed cassette is not installed like a wall unit. It requires more precise preparation, especially in existing ceilings. During a technical visit, we generally validate the following points:\u003c\/p\u003e\u003cp data-start=\"9488\" data-end=\"9717\"\u003e\u003cstrong data-start=\"9488\" data-end=\"9518\"\u003e1. Ceiling structure\u003c\/strong\u003e\u003cbr data-start=\"9518\" data-end=\"9521\"\u003eThe indoor unit must be properly suspended using threaded rods and anchored to a structure capable of supporting its weight. The suspended ceiling should never be the sole support.\u003c\/p\u003e\n\u003cp data-start=\"9719\" data-end=\"9924\"\u003e\u003cstrong data-start=\"9719\" data-end=\"9766\"\u003e2. Space available above the ceiling\u003c\/strong\u003e\u003cbr data-start=\"9766\" data-end=\"9769\"\u003eThe \u003cstrong data-start=\"9781\" data-end=\"9794\"\u003eKNUDB181A\u003c\/strong\u003e cassette measures approximately \u003cstrong data-start=\"9810\" data-end=\"9830\"\u003e10 inches in height\u003c\/strong\u003e. Provision must also be made for access to connections, drain, wiring, and service panels.\u003c\/p\u003e\n\u003cp data-start=\"9926\" data-end=\"10213\"\u003e\u003cstrong data-start=\"9926\" data-end=\"9959\"\u003e3. Condensate drainage\u003c\/strong\u003e\u003cbr data-start=\"9959\" data-end=\"9962\"\u003eThe unit includes an integrated condensate pump with a published lift capacity of approximately \u003cstrong data-start=\"10058\" data-end=\"10072\"\u003e27 9\/16 inches\u003c\/strong\u003e. Proper slope and routing are still necessary to prevent backflows, odors, overflows, or safety shutdowns.\u003c\/p\u003e\n\u003cp data-start=\"10215\" data-end=\"10567\"\u003e\u003cstrong data-start=\"10215\" data-end=\"10257\"\u003e4. Outdoor unit location\u003c\/strong\u003e\u003cbr data-start=\"10257\" data-end=\"10260\"\u003eThe \u003cstrong data-start=\"10280\" data-end=\"10293\"\u003eKUSXB181A\u003c\/strong\u003e outdoor unit must be installed with required clearances, a stable base, reasonable protection against snow accumulation, and access for maintenance. On the \u003cstrong data-start=\"10455\" data-end=\"10468\"\u003eNorth Shore\u003c\/strong\u003e and \u003cstrong data-start=\"10475\" data-end=\"10487\"\u003eSouth Shore\u003c\/strong\u003e, prevailing winds and snow drifts must be considered from the design stage.\u003c\/p\u003e\n\u003cp data-start=\"10569\" data-end=\"10825\"\u003e\u003cstrong data-start=\"10569\" data-end=\"10607\"\u003e5. Required architectural panel\u003c\/strong\u003e\u003cbr data-start=\"10607\" data-end=\"10610\"\u003eThe compatible 2x2 cassette panel \u003cstrong data-start=\"10648\" data-end=\"10660\"\u003ePT-QAGW0\u003c\/strong\u003e is required to complete the installation. This is not a secondary decorative detail: the panel ensures proper air diffusion and filter access.\u003c\/p\u003e\n\u003cp data-start=\"10827\" data-end=\"11068\"\u003e\u003cstrong data-start=\"10827\" data-end=\"10847\"\u003e6. Electricity\u003c\/strong\u003e\u003cbr data-start=\"10847\" data-end=\"10850\"\u003eThe system operates at \u003cstrong data-start=\"10875\" data-end=\"10888\"\u003e208-230 V\u003c\/strong\u003e, with a minimum circuit ampacity of \u003cstrong data-start=\"10931\" data-end=\"10939\"\u003e16 A\u003c\/strong\u003e and a maximum overcurrent protection of \u003cstrong data-start=\"10986\" data-end=\"10994\"\u003e25 A\u003c\/strong\u003e. We always validate the electrical panel before the final submission.\u003c\/p\u003e\n\u003ch3 data-section-id=\"144pvgt\" data-start=\"11070\" data-end=\"11105\"\u003eCommon mistakes to avoid\u003c\/h3\u003e\n\u003cp data-start=\"11107\" data-end=\"11362\"\u003eA \u003cstrong data-start=\"11111\" data-end=\"11151\"\u003eceiling cassette installation\u003c\/strong\u003e requires more coordination than a simple wall-mounted air conditioner replacement. Here are the most common mistakes we see when customers call us after a poorly planned installation elsewhere.\u003c\/p\u003e\n\u003cp data-start=\"11364\" data-end=\"11568\"\u003e\u003cstrong data-start=\"11364\" data-end=\"11392\"\u003eUnderestimating drainage\u003c\/strong\u003e\u003cbr data-start=\"11392\" data-end=\"11395\"\u003eA cooling cassette produces water. If the condensate line is poorly designed, the unit may shut down, leak, or cause moisture problems in the ceiling.\u003c\/p\u003e\n\u003cp data-start=\"11570\" data-end=\"11809\"\u003e\u003cstrong data-start=\"11570\" data-end=\"11615\"\u003eInstalling the unit too close to an obstacle\u003c\/strong\u003e\u003cbr data-start=\"11615\" data-end=\"11618\"\u003eA light fixture, a beam, a partial partition, or a dropped ceiling can hinder four-way airflow. The result: one area that is too cold and another that does not receive enough air.\u003c\/p\u003e\n\u003cp data-start=\"11811\" data-end=\"12086\"\u003e\u003cstrong data-start=\"11811\" data-end=\"11865\"\u003eChoosing capacity based solely on area\u003c\/strong\u003e\u003cbr data-start=\"11865\" data-end=\"11868\"\u003eArea is useful information, but insufficient. Windows, solar orientation, number of occupants, electrical equipment, ceiling height, and insulation strongly influence the HVAC load.\u003c\/p\u003e\n\u003cp data-start=\"12088\" data-end=\"12419\"\u003e\u003cstrong data-start=\"12088\" data-end=\"12125\"\u003eIgnoring piping length\u003c\/strong\u003e\u003cbr data-start=\"12125\" data-end=\"12128\"\u003eThe longer the piping, the more capacity losses must be considered. For the 18,000 BTU model, the equivalent length can reach \u003cstrong data-start=\"12279\" data-end=\"12289\"\u003e164 ft\u003c\/strong\u003e, but cooling capacity decreases as distance increases. Rigorous design avoids unpleasant surprises.\u003c\/p\u003e\n\u003cp data-start=\"12421\" data-end=\"12653\"\u003e\u003cstrong data-start=\"12421\" data-end=\"12452\"\u003eForgetting maintenance access\u003c\/strong\u003e\u003cbr data-start=\"12452\" data-end=\"12455\"\u003eA properly installed cassette must remain accessible. The washable filter, condensate pump, connections, and panel must not become unreachable after the ceiling is finished.\u003c\/p\u003e\n\u003ch3 data-section-id=\"165zry3\" data-start=\"12655\" data-end=\"12698\"\u003eHVAC maintenance: simple, but essential\u003c\/h3\u003e\n\u003cp data-start=\"12700\" data-end=\"13024\"\u003eThe indoor unit's \u003cstrong data-start=\"12703\" data-end=\"12721\"\u003ewashable filter\u003c\/strong\u003e must be cleaned regularly. In a residence, the frequency depends on dust, pets, usage, and season. In a commercial setting, more frequent cleaning is often necessary, especially if the door opens frequently or if the environment generates particles.\u003c\/p\u003e\n\u003cp data-start=\"13026\" data-end=\"13075\"\u003eGood \u003cstrong data-start=\"13033\" data-end=\"13051\"\u003eHVAC maintenance\u003c\/strong\u003e generally includes:\u003c\/p\u003e\n\u003cul data-start=\"13077\" data-end=\"13482\"\u003e\n\u003cli data-section-id=\"b2gca1\" data-start=\"13077\" data-end=\"13099\"\u003eFilter cleaning.\u003c\/li\u003e\n\u003cli data-section-id=\"1bbw8f1\" data-start=\"13100\" data-end=\"13144\"\u003eCassette and panel inspection.\u003c\/li\u003e\n\u003cli data-section-id=\"1la1mze\" data-start=\"13145\" data-end=\"13196\"\u003eDrain and condensate pump inspection.\u003c\/li\u003e\n\u003cli data-section-id=\"11df52l\" data-start=\"13197\" data-end=\"13246\"\u003ePreventive evaporator cleaning as needed.\u003c\/li\u003e\n\u003cli data-section-id=\"4pg844\" data-start=\"13247\" data-end=\"13284\"\u003eOutdoor unit inspection.\u003c\/li\u003e\n\u003cli data-section-id=\"1jdjf1f\" data-start=\"13285\" data-end=\"13371\"\u003eChecking operating pressures and temperatures during a service call.\u003c\/li\u003e\n\u003cli data-section-id=\"lspqhm\" data-start=\"13372\" data-end=\"13417\"\u003eHeating mode validation before winter.\u003c\/li\u003e\n\u003cli data-section-id=\"f3x8v5\" data-start=\"13418\" data-end=\"13482\"\u003eCooling mode validation before summer heat.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"13484\" data-end=\"13853\"\u003eThe optional \u003cstrong data-start=\"13510\" data-end=\"13523\"\u003ePWFMDD200\u003c\/strong\u003e Wi-Fi module, compatible with the LG ThinQ app, can also facilitate daily management: remote settings, weekly schedules, consultation of certain alerts, and filter usage monitoring. For commercial buildings, certain wall controllers or integration solutions can be considered depending on the project.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1ih646h\" data-start=\"13855\" data-end=\"13905\"\u003eRepresentative example: glazed premises in Montreal\u003c\/h3\u003e\n\u003cp data-start=\"13907\" data-end=\"14348\"\u003eIn a typical commercial premises in eastern \u003cstrong data-start=\"13952\" data-end=\"13964\"\u003eMontreal\u003c\/strong\u003e, the client wanted to avoid a visible wall-mounted unit behind the counter. The premises had a glazed facade, a suspended ceiling, and walls used for displays. An LG 18,000 BTU 2x2 cassette type represented a logical option because it allowed air to be diffused towards the client area, the counter, and the back of the premises without concentrating the flow on a single wall.\u003c\/p\u003e\n\u003cp data-start=\"14350\" data-end=\"14807\"\u003eThe critical point was not just the choice of model. Our checks focused primarily on the exact location in the ceiling, the clearance around the cassette, the path of the condensate line, the position of the outdoor unit, and the perceived noise level from the reception area. This type of project shows why an on-site evaluation is essential: two premises of the same size may require very different decisions.\u003c\/p\u003e\n\u003ch3 data-section-id=\"1h9tmfm\" data-start=\"14809\" data-end=\"14880\"\u003eRepresentative example: office in Laval with fixed workstations\u003c\/h3\u003e\n\u003cp data-start=\"14882\" data-end=\"15411\"\u003eIn an office in \u003cstrong data-start=\"14899\" data-end=\"14908\"\u003eLaval\u003c\/strong\u003e, employee comfort was the priority. A wall-mounted unit would have blown directly towards certain desks, creating a frequent complaint: one person is too cold while another is not cooled enough. The ceiling cassette allows for more balanced air distribution. In this type of space, we pay particular attention to the position of workstations, indoor noise level, occupancy schedules, and the possibility of using milder ventilation settings.\u003c\/p\u003e\n\u003cp data-start=\"15413\" data-end=\"15723\"\u003eWith a published indoor noise level of \u003cstrong data-start=\"15455\" data-end=\"15472\"\u003e36 to 41 dB(A)\u003c\/strong\u003e depending on speed, the LG 18,000 BTU model can be suitable for environments where quiet is important, provided the mechanical installation is properly done and the cassette is not placed directly above a sensitive workstation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"n2p3lb\" data-start=\"15725\" data-end=\"15764\"\u003eWhy AirGreen for this LG model\u003c\/h3\u003e\n\u003cp data-start=\"15766\" data-end=\"16079\"\u003eChoosing AirGreen for an \u003cstrong data-start=\"15792\" data-end=\"15835\"\u003eLG cassette heat pump installation\u003c\/strong\u003e means getting more than a standard installation. We analyze the building, the interior configuration, ceiling feasibility, noise level, drainage, outdoor location, and electrical requirements before confirming the solution.\u003c\/p\u003e\n\u003cp data-start=\"16081\" data-end=\"16627\"\u003eOur clients seek us out for residential, commercial, and multi-dwelling projects in \u003cstrong data-start=\"16174\" data-end=\"16186\"\u003eMontreal\u003c\/strong\u003e, \u003cstrong data-start=\"16188\" data-end=\"16197\"\u003eLaval\u003c\/strong\u003e, \u003cstrong data-start=\"16199\" data-end=\"16212\"\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong data-start=\"16221\" data-end=\"16234\"\u003eNorth Shore\u003c\/strong\u003e, the \u003cstrong data-start=\"16239\" data-end=\"16251\"\u003eSouth Shore\u003c\/strong\u003e, and in \u003cstrong data-start=\"16258\" data-end=\"16272\"\u003eMontérégie\u003c\/strong\u003e because we combine installation, after-sales service, maintenance, and support for applicable grants. AirGreen holds \u003cstrong data-start=\"16433\" data-end=\"16455\"\u003eRBQ license # 5645-9605-01\u003c\/strong\u003e, has \u003cstrong data-start=\"16506\" data-end=\"16514\"\u003e5M$\u003c\/strong\u003e liability insurance, and works with experienced refrigeration technicians who understand the real constraints of Quebec buildings.\u003c\/p\u003e\n\u003cp data-start=\"16629\" data-end=\"16946\"\u003eWe also favor clear quotes. Before starting work, we send a detailed final offer so that the client knows what is included: equipment, labor, required accessories, materials, installation, electrical specifics, drainage, outdoor support, and available options.\u003c\/p\u003e\n\u003ch3 data-section-id=\"qwtoqf\" data-start=\"16948\" data-end=\"17003\"\u003eFor which clients is this product most relevant\u003c\/h3\u003e\n\u003cp data-start=\"17005\" data-end=\"17095\"\u003eThe \u003cstrong data-start=\"17008\" data-end=\"17057\"\u003eLG 2x2 Cassette Type Ceiling Unit | 18,000 BTU\u003c\/strong\u003e is particularly relevant for:\u003c\/p\u003e\n\u003cul data-start=\"17097\" data-end=\"17617\"\u003e\n\u003cli data-section-id=\"1sfifk2\" data-start=\"17097\" data-end=\"17162\"\u003eA business owner who wants to keep their walls clear.\u003c\/li\u003e\n\u003cli data-section-id=\"1qo93j8\" data-start=\"17163\" data-end=\"17242\"\u003eAn office manager looking for more uniform air distribution.\u003c\/li\u003e\n\u003cli data-section-id=\"qvda0j\" data-start=\"17243\" data-end=\"17314\"\u003eA condo or home owner who wants a discreet solution.\u003c\/li\u003e\n\u003cli data-section-id=\"b1ei04\" data-start=\"17315\" data-end=\"17364\"\u003eA space with a suspended ceiling and an open area.\u003c\/li\u003e\n\u003cli data-section-id=\"dulpop\" data-start=\"17365\" data-end=\"17420\"\u003eA room where a wall-mounted unit would be poorly positioned.\u003c\/li\u003e\n\u003cli data-section-id=\"uurhm8\" data-start=\"17421\" data-end=\"17533\"\u003eA space requiring both \u003cstrong data-start=\"17455\" data-end=\"17472\"\u003eair conditioning\u003c\/strong\u003e, \u003cstrong data-start=\"17474\" data-end=\"17487\"\u003eheating\u003c\/strong\u003e, \u003cstrong data-start=\"17489\" data-end=\"17510\"\u003edehumidification\u003c\/strong\u003e, and acoustic comfort.\u003c\/li\u003e\n\u003cli data-section-id=\"13xk9i4\" data-start=\"17534\" data-end=\"17617\"\u003eA project where interior appearance is as important as energy performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"17619\" data-end=\"17942\"\u003eHowever, it is not the best choice for every building. If the ceiling does not offer enough space, if drainage cannot be managed correctly, if the thermal load exceeds the realistic capacity of the unit, or if a multi-zone system would be more appropriate, we will clearly mention it during the evaluation.\u003c\/p\u003e\n\u003ch3 data-section-id=\"g5m4fg\" data-start=\"17944\" data-end=\"17994\"\u003eContact AirGreen for an accurate quote\u003c\/h3\u003e\n\u003cp data-start=\"17996\" data-end=\"18392\"\u003eTo find out if the \u003cstrong data-start=\"18014\" data-end=\"18067\"\u003eLG: 2x2 Cassette Type Ceiling Unit | 18,000 BTU\u003c\/strong\u003e is suitable for your space, contact AirGreen. We can evaluate your building, confirm potential eligibility for subsidy programs, check installation constraints, and provide you with a clear quote for your \u003cstrong data-start=\"18317\" data-end=\"18391\"\u003eHVAC project in Montreal, Laval, Longueuil, on the North Shore, or on the South Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"18394\" data-end=\"18539\"\u003e\u003cstrong data-start=\"18394\" data-end=\"18426\"\u003eCall us at 514-316-2973\u003c\/strong\u003e or write to \u003cstrong data-start=\"18440\" data-end=\"18461\"\u003e\u003ca data-start=\"18442\" data-end=\"18459\" class=\"decorated-link cursor-pointer\" rel=\"noopener\"\u003esales@airgreen.ca\u003cspan aria-hidden=\"true\" class=\"ms-0.5 inline-block align-middle leading-none\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" data-rtl-flip=\"\" class=\"block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]\"\u003e\u003cuse fill=\"currentColor\" href=\"\/cdn\/assets\/sprites-core-0da2cb3c.svg#304883\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/strong\u003e to schedule an estimate or get more information about this LG model.\u003c\/p\u003e","brand":"LG","offers":[{"title":"Default Title","offer_id":53340600041764,"sku":"KNUDB181A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/CASSETTEDEPLAFONDr32MONTREAL_LAVAL_LONGUEUIL_RIVESUD_RIVENORD_4d221109-08c7-4721-a256-0851d740d6f9.png?v=1777635030","url":"https:\/\/airgreen.ca\/en\/products\/lg-plafonnier-de-type-cassette-2x2-18-000-btu","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}