{"product_id":"mini-split-senville-leto-30000-btu-montreal-laval-rive-sud","title":"SENVILLE LETO Mini-Split | 30000 BTU | Montréal, Laval, South Shore","description":"\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003e30,000 BTU in a single wall-mounted unit: a solution designed for large open areas, provided the project is properly sized\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSENVILLE LETO 30,000 BTU\u003c\/strong\u003e falls into a very different category from the 9,000, 12,000, or 18,000 BTU wall-mounted heat pumps that we commonly install in a bedroom, condo, or small living room. With a rated capacity of \u003cstrong\u003e30,000 BTU\/h\u003c\/strong\u003e, this unit is intended instead for \u003cstrong\u003elarge open areas, basements, commercial spaces, large living rooms, workspaces, and large residential areas\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAt \u003cstrong\u003eAirGreen\u003c\/strong\u003e, we mainly consider this type of heat pump when a homeowner wants to treat a large volume with a single wall-mounted head. However, the question is never simply whether “30,000 BTU is enough.” It is also necessary to determine whether air can actually circulate throughout the area, whether the unit is properly sized, whether the electrical installation can power it, and whether its winter performance meets the homeowner’s expectations.\u003c\/p\u003e\n\u003cp\u003eThe combination offered consists of the \u003cstrong\u003eSENL-30CD-OL\u003c\/strong\u003e outdoor unit and the \u003cstrong\u003eSENL-30CD-ILL\u003c\/strong\u003e indoor unit. The official AHRI certificate bears the number \u003cstrong\u003e215735292\u003c\/strong\u003e and confirms that this combination is active and marketed in Canada, with a rated cooling capacity of \u003cstrong\u003e30,000 BTU\/h\u003c\/strong\u003e, a \u003cstrong\u003eSEER2 of 20.00\u003c\/strong\u003e, an \u003cstrong\u003eEER2 of 11.00\u003c\/strong\u003e, a rated heating capacity of \u003cstrong\u003e30,000 BTU\/h\u003c\/strong\u003e, and an \u003cstrong\u003eHSPF2 Region IV of 9.20\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eKey technical features to remember\u003c\/h3\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eFeature\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eSENVILLE LETO 30,000 BTU\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor unit\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSENL-30CD-OL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor unit\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSENL-30CD-ILL\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAHRI reference\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e215735292\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated cooling capacity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e30,000 BTU\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6,200 to 33,700 BTU\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated heating capacity\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e30,000 BTU\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating range\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e11,800 to 33,700 BTU\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSEER2\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e20,0\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEER2\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e11,0\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Region IV\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e9,2\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHSPF2 Region V\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e6,9\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated COP\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3,0\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigerant\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eR454B\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e208\/230 V, single-phase, 60 Hz\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMCA\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e28 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum protection\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e30 A\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePiping\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3\/8 in – 5\/8 in\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum indoor airflow\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e853.5 CFM\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDehumidification\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e3.6 L\/h\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndoor sound level\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e34 to 57 dB(A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutdoor sound level\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e60.5 dB(A)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWiFi \/ Alexa\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eYes\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVertical louvers\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomatic\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorizontal louvers\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eAutomatic\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe Senville technical data sheet confirms, among other things, a power supply of \u003cstrong\u003e208\/230 V\u003c\/strong\u003e, a voltage range of 187 to 253 V, an MCA of 28 A, and a maximum protection of 30 A. It also documents the modulation ranges in heating and cooling modes. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eTrue modulation capacity despite the 30,000 BTU format\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003e30,000 BTU\u003c\/strong\u003e rating does not mean that the compressor operates constantly at full capacity.\u003c\/p\u003e\n\u003cp\u003eIn cooling mode, the published range is \u003cstrong\u003e6,200 to 33,700 BTU\/h\u003c\/strong\u003e. In heating mode, it is \u003cstrong\u003e11,800 to 33,700 BTU\/h\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis modulation is important in a large open-concept area.\u003c\/p\u003e\n\u003cp\u003eLet’s consider a situation we regularly encounter during our estimates in \u003cstrong\u003eMontreal, Laval, Longueuil, and the South Shore\u003c\/strong\u003e: a finished basement becomes very hot after several hours of sunlight and activity. The heat pump can increase its output to bring the temperature back to the setpoint. Once the zone has stabilized, the Inverter can reduce its output rather than operating continuously according to an on-off cycle.\u003c\/p\u003e\n\u003cp\u003eThis helps improve:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003etemperature stability;\u003c\/li\u003e\n\u003cli\u003eelectricity consumption;\u003c\/li\u003e\n\u003cli\u003eacoustic comfort;\u003c\/li\u003e\n\u003cli\u003ecycle duration;\u003c\/li\u003e\n\u003cli\u003ehumidity control.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSenville states that its Inverter technology automatically adjusts output according to demand and indicates, for this series, a potential consumption reduction of up to 20% depending on the comparison conditions used by the manufacturer. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e1,250 to 1,500 sq. ft.: useful as a reference, but insufficient for choosing the capacity on its own\u003c\/h3\u003e\n\u003cp\u003eThe documentation presents the SENVILLE LETO 30,000 BTU as suitable for approximately \u003cstrong\u003e1,250 to 1,500 sq. ft.\u003c\/strong\u003e, particularly for large rooms, offices, and basements. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis indication should be used as a starting point, not as a sizing formula.\u003c\/p\u003e\n\u003cp\u003eA 1,400 sq. ft. basement in Laval that is largely open and located beneath a well-insulated house does not have the same needs as a 1,400 sq. ft. commercial space in Montreal with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ean exterior door that is frequently opened;\u003c\/li\u003e\n\u003cli\u003elarge display windows;\u003c\/li\u003e\n\u003cli\u003eseveral occupants;\u003c\/li\u003e\n\u003cli\u003ecomputers or equipment generating heat;\u003c\/li\u003e\n\u003cli\u003ehigher ceilings;\u003c\/li\u003e\n\u003cli\u003esignificant solar gains.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eConversely, a large unit installed in a highly compartmentalized space can produce a great deal of air without properly conditioning distant rooms.\u003c\/p\u003e\n\u003ch3\u003eA common mistake: trying to cool several closed bedrooms with a single 30,000 BTU indoor unit\u003c\/h3\u003e\n\u003cp\u003eThis is a point we often explain during estimates.\u003c\/p\u003e\n\u003cp\u003eA wall-mounted heat pump does not distribute air like a central ducted system. Installing a \u003cstrong\u003e30,000 BTU\u003c\/strong\u003e unit in a hallway does not mean that four bedrooms behind closed doors will each receive their share of the capacity.\u003c\/p\u003e\n\u003cp\u003eIn this scenario, adding BTUs is not necessarily the solution.\u003c\/p\u003e\n\u003cp\u003eWe need to consider:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe indoor unit’s position;\u003c\/li\u003e\n\u003cli\u003ethe direction of the airflow;\u003c\/li\u003e\n\u003cli\u003ethe layout of the space;\u003c\/li\u003e\n\u003cli\u003edoors and partitions;\u003c\/li\u003e\n\u003cli\u003eceiling height;\u003c\/li\u003e\n\u003cli\u003ethe number of zones actually requiring conditioning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn a large open-concept area, this LETO can be highly suitable. In a heavily compartmentalized home, a multi-zone system or several units may sometimes offer better room-by-room control.\u003c\/p\u003e\n\u003ch3\u003eAn airflow rate of 853.5 CFM in Turbo mode\u003c\/h3\u003e\n\u003cp\u003eA 30,000 BTU heat pump must move a significant amount of air.\u003c\/p\u003e\n\u003cp\u003eThe technical brochure indicates the following airflow rates:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e853.5 CFM in Turbo mode\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e732.8 CFM at high speed\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e470.9 CFM at medium speed\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e353.2 CFM at low speed\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis airflow is why the indoor unit’s location must be planned carefully.\u003c\/p\u003e\n\u003cp\u003eIn a large rectangular room, we generally aim to use the length of the room rather than immediately directing the air toward a nearby wall. The \u003cstrong\u003eautomatic vertical and horizontal louvers\u003c\/strong\u003e then help distribute the airflow more evenly throughout the area.\u003c\/p\u003e\n\u003ch3\u003eSound level: the high airflow is naturally more noticeable\u003c\/h3\u003e\n\u003cp\u003eThe SENVILLE LETO 30,000 BTU has indoor sound levels of approximately:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e57 \/ 51 \/ 44.5 \/ 34 dB(A)\u003c\/strong\u003e depending on the speed.\u003c\/p\u003e\n\u003cp\u003eThe outdoor unit is rated at \u003cstrong\u003e60.5 dB(A)\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eTherefore, this heat pump should not be compared directly with a small bedroom unit capable of dropping below 20 dB(A). This is an appliance capable of moving up to more than 850 CFM.\u003c\/p\u003e\n\u003cp\u003eFor an installation near a bedroom, on a balcony, or in a narrow passage between two properties, we must also consider the position of the outdoor unit, vibrations, and sound reflection from nearby walls.\u003c\/p\u003e\n\u003ch3\u003eAn interesting dehumidification capacity\u003c\/h3\u003e\n\u003cp\u003eThe technical specifications indicate moisture removal of approximately \u003cstrong\u003e3.6 liters per hour\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis is particularly relevant in \u003cstrong\u003elarge basements in Greater Montreal\u003c\/strong\u003e, where summer discomfort is often caused as much by humidity as by temperature.\u003c\/p\u003e\n\u003cp\u003eA properly sized unit can run long enough to cool the space and remove some of the humidity from the air.\u003c\/p\u003e\n\u003cp\u003eConversely, installing an oversized unit for the space can shorten operating cycles and reduce dehumidification quality.\u003c\/p\u003e\n\u003ch3\u003eHeating: the rated capacity must be distinguished from performance in extreme cold\u003c\/h3\u003e\n\u003cp\u003eThe LETO provides a rated heating capacity of \u003cstrong\u003e30,000 BTU\/h\u003c\/strong\u003e, with an advertised range reaching up to 33,700 BTU\/h under certain conditions. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHowever, the accompanying commercial documentation presents this series as capable of heating down to \u003cstrong\u003e-15 °C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe AirGreen specifications also indicate approximately:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e19,000 BTU\/h at -8 °C\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e19,700 BTU\/h at -15 °C\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis decrease compared with the nominal 30,000 BTU is normal: a heat pump’s available capacity can vary with the outdoor temperature.\u003c\/p\u003e\n\u003cp\u003eThat is why we avoid presenting the rated capacity as though it were available under all winter conditions.\u003c\/p\u003e\n\u003ch3\u003eENERGY STAR, but not the “cold climate” classification\u003c\/h3\u003e\n\u003cp\u003eThe SENL-30CD-OL \/ SENL-30CD-ILL combination is listed on our product page as ENERGY STAR, with identifier 4479008, but not as ENERGY STAR – Cold Climate.\u003c\/p\u003e\n\u003cp\u003eThis distinction is important for a Quebec homeowner.\u003c\/p\u003e\n\u003cp\u003eA heat pump can be efficient and ENERGY STAR certified without necessarily meeting the specific criteria for the cold-climate classification.\u003c\/p\u003e\n\u003cp\u003eFor someone primarily looking to reduce the use of electric baseboard heaters during very cold periods, we can therefore compare this LETO with a heat pump specifically certified for cold climates before making a decision.\u003c\/p\u003e\n\u003ch3\u003eSEER2 20 and HSPF2 9.2: how to interpret these values\u003c\/h3\u003e\n\u003cp\u003eThe official AHRI certificate confirms:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSEER2: 20.00\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEER2: 11.00\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHSPF2 Region IV: 9.20\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSEER2\u003c\/strong\u003e measures seasonal cooling efficiency. \u003cstrong\u003eHSPF2\u003c\/strong\u003e concerns seasonal heating efficiency.\u003c\/p\u003e\n\u003cp\u003eThese values are mainly useful for comparing several pieces of equipment using standardized methods.\u003c\/p\u003e\n\u003cp\u003eOn their own, they do not make it possible to predict the exact amount of a Hydro-Québec bill. Actual consumption will depend, among other things, on the requested temperature, the building, insulation, number of hours of use, and the heating system being replaced or supplemented.\u003c\/p\u003e\n\u003ch3\u003eR454B and 3\/8 in – 5\/8 in piping\u003c\/h3\u003e\n\u003cp\u003eThis new version uses \u003cstrong\u003eR454B refrigerant\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe brochure indicates that the system is precharged for up to \u003cstrong\u003e25 feet of refrigerant lines\u003c\/strong\u003e. For an installation using a 50-foot kit, the manufacturer specifies that an additional charge must be added on site by the installer. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor the 30,000 BTU combination, the specified piping is \u003cstrong\u003e3\/8 in – 5\/8 in\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe actual length must always be measured before installation. A project in which the indoor unit is on the second floor and the condenser is at the back of the building may require much more material than a back-to-back installation.\u003c\/p\u003e\n\u003ch3\u003eRequired electrical installation: 208\/230 V, MCA 28 A, MOP 30 A\u003c\/h3\u003e\n\u003cp\u003eThis 30,000 BTU LETO operates on a \u003cstrong\u003e208\/230 V single-phase\u003c\/strong\u003e power supply.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer's data indicates:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMCA: 28 A\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003emaximum protection: 30 A\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003especified communication wiring: \u003cstrong\u003e14 × 4 AWG\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor our HVAC installations in \u003cstrong\u003eMontreal, Laval, Longueuil, the South Shore, and the North Shore\u003c\/strong\u003e, we therefore check the electrical panel before the work begins.\u003c\/p\u003e\n\u003cp\u003eAn available breaker in the panel is not always sufficient. You must ensure that the circuit, wiring, outdoor disconnect, and the entire electrical installation are suitable for the selected model.\u003c\/p\u003e\n\u003ch3\u003eAn indoor unit much larger than a 12,000 BTU unit\u003c\/h3\u003e\n\u003cp\u003eThe dimensions should also be checked before choosing the wall.\u003c\/p\u003e\n\u003cp\u003eThe indoor unit measures approximately:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e49.57 in wide × 11.10 in deep × 14.25 in high\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIts weight is approximately \u003cstrong\u003e40.34 lb\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe outdoor unit measures approximately:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e37.24 × 16.14 × 31.89 in\u003c\/strong\u003e,\u003c\/p\u003e\n\u003cp\u003efor a weight of approximately \u003cstrong\u003e150.35 lb\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWe are therefore far from the very compact format of a small 9,000 BTU heat pump.\u003c\/p\u003e\n\u003cp\u003eThe available width above windows, doors, bookcases, or cabinets must be checked, along with the necessary clearances around the units.\u003c\/p\u003e\n\u003ch2\u003eAirGreen installation: making the most of 30,000 BTU without creating an oversized or poorly distributed system\u003c\/h2\u003e\n\u003ch3\u003eA typical scenario: a large open basement on the South Shore\u003c\/h3\u003e\n\u003cp\u003eLet’s consider a project representative of what we see in properties in \u003cstrong\u003eBoucherville, Longueuil, Saint-Hubert, or Saint-Bruno\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe homeowner has a large basement comprising a family room, a workout area, and a workspace, but very few permanent partitions. In summer, humidity is high and the existing small air-conditioning solutions are no longer sufficient.\u003c\/p\u003e\n\u003cp\u003eA \u003cstrong\u003e30,000 BTU\u003c\/strong\u003e heat pump may be suitable if the load calculation justifies it and if we can position the unit to project air along the length of the space.\u003c\/p\u003e\n\u003cp\u003eThe same unit would be much less suitable if this basement were divided into five rooms whose doors generally remain closed.\u003c\/p\u003e\n\u003cp\u003eThis is why we always consider \u003cstrong\u003ethe building’s layout before the capacity listed on the unit\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWi-Fi and Alexa integration\u003c\/h3\u003e\n\u003cp\u003eThe 30,000 BTU LETO can be controlled remotely, and the brochure indicates integration with \u003cstrong\u003eAlexa\u003c\/strong\u003e, allowing users in particular:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eto turn the system on or off;\u003c\/li\u003e\n\u003cli\u003eto adjust the setpoint;\u003c\/li\u003e\n\u003cli\u003eto change the settings;\u003c\/li\u003e\n\u003cli\u003eto create schedules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Alexa USB module is one of the items listed in the product documentation. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a store, office, or cottage, this feature can be particularly useful because it prevents the unit from running unnecessarily at the same setpoint during an extended absence.\u003c\/p\u003e\n\u003ch3\u003eLogisVert rebate: $950 listed on the AirGreen page, but the installation date remains decisive\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen product page currently lists a \u003cstrong\u003e$950 LogisVert provincial rebate\u003c\/strong\u003e, according to its update dated November 26, 2025.\u003c\/p\u003e\n\u003cp\u003eThis value corresponds to the declared heating capacity at low temperatures and the rules applicable to the model when the information sheet was updated.\u003c\/p\u003e\n\u003cp\u003eNevertheless, the situation must be verified at the time of installation. Hydro-Québec specifies that heat pumps installed since \u003cstrong\u003eNovember 26, 2025, must be ENERGY STAR certified\u003c\/strong\u003e to be eligible, and that the list of models and the amounts may change over time. \u003cspan class=\"contents\"\u003e\u003cspan class=\"\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, we therefore prefer to confirm the \u003cstrong\u003eAHRI number 215735292\u003c\/strong\u003e, the two exact models, and the scheduled installation date before presenting the final amount of financial assistance as guaranteed.\u003c\/p\u003e\n\u003ch3\u003eWarranty: an important difference to understand between the brochure and the AirGreen offer\u003c\/h3\u003e\n\u003cp\u003eThe Senville brochure provided for this model indicates a warranty of \u003cstrong\u003e5 years on the compressor and 5 years on parts\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe AirGreen listing, for its part, shows \u003cstrong\u003e10-10-0 years\u003c\/strong\u003e of coverage and indicates that an additional warranty may be available.\u003c\/p\u003e\n\u003cp\u003eThese two pieces of information must not be mixed up. Applicable coverage may depend on the warranty program, registration, and commercial terms associated with the installation. We therefore always confirm with the customer the \u003cstrong\u003eexact warranty stated on the quote\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWhat type of project do we primarily recommend the LETO 30,000 BTU for?\u003c\/h3\u003e\n\u003cp\u003eThis heat pump is particularly worth considering for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea \u003cstrong\u003elarge residential open-concept area\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003ea \u003cstrong\u003elarge basement\u003c\/strong\u003e;\u003c\/li\u003e\n\u003cli\u003ea loft;\u003c\/li\u003e\n\u003cli\u003ea workshop;\u003c\/li\u003e\n\u003cli\u003ean office;\u003c\/li\u003e\n\u003cli\u003ea commercial space;\u003c\/li\u003e\n\u003cli\u003ea large common area;\u003c\/li\u003e\n\u003cli\u003ea space where high airflow is required.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is less suitable when a homeowner is primarily looking for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eheating several isolated bedrooms behind closed doors;\u003c\/li\u003e\n\u003cli\u003ea heat pump intended for primary heating during extreme cold;\u003c\/li\u003e\n\u003cli\u003ea very compact indoor unit;\u003c\/li\u003e\n\u003cli\u003ea unit specifically designed according to ENERGY STAR – Cold Climate criteria.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy professional sizing is especially important at 30,000 BTU\u003c\/h3\u003e\n\u003cp\u003eWith a small heat pump, an error of a few thousand BTUs can already reduce comfort. With a \u003cstrong\u003e30,000 BTU\u003c\/strong\u003e unit, a sizing error becomes even more significant.\u003c\/p\u003e\n\u003cp\u003eWe check, among other things:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003ecooling load;\u003c\/li\u003e\n\u003cli\u003eheat losses;\u003c\/li\u003e\n\u003cli\u003ethe actual open area;\u003c\/li\u003e\n\u003cli\u003eair circulation;\u003c\/li\u003e\n\u003cli\u003eelectrical capacity;\u003c\/li\u003e\n\u003cli\u003ethe drain position;\u003c\/li\u003e\n\u003cli\u003ethe refrigerant line route;\u003c\/li\u003e\n\u003cli\u003ethe outdoor unit support;\u003c\/li\u003e\n\u003cli\u003eclearances;\u003c\/li\u003e\n\u003cli\u003efuture access for maintenance.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eWe aim to install the capacity required, not simply the highest capacity that can fit in the building.\u003c\/p\u003e\n\u003ch3\u003eHave AirGreen install the SENVILLE LETO 30,000 BTU\u003c\/h3\u003e\n\u003cp\u003eAt \u003cstrong\u003eAirGreen Heat Pumps, Air Conditioning \u0026amp; Heating\u003c\/strong\u003e, we can verify whether the \u003cstrong\u003eSENVILLE LETO 30,000 BTU R454B SENL-30CD-OL \/ SENL-30CD-ILL\u003c\/strong\u003e is truly suitable for your space and compare this model with other heat pumps of similar capacity.\u003c\/p\u003e\n\u003cp\u003eWe serve \u003cstrong\u003eMontreal, Laval, Longueuil, the South Shore, the North Shore, and Montérégie\u003c\/strong\u003e for \u003cstrong\u003ewall-mounted heat pump installation\u003c\/strong\u003e, residential and commercial HVAC projects, and after-sales service.\u003c\/p\u003e\n\u003cp\u003eTo obtain a quote, confirm the \u003cstrong\u003eLogisVert subsidy\u003c\/strong\u003e, plan the electrical supply, or determine whether 30,000 BTU is suitable for your building, contact \u003cstrong\u003eAirGreen at 514-316-2973\u003c\/strong\u003e or \u003cstrong\u003e\u003ca class=\"decorated-link cursor-pointer\" rel=\"noopener\"\u003esales@airgreen.ca\u003c\/a\u003e\u003c\/strong\u003e.\u003c\/p\u003e","brand":"Senville","offers":[{"title":"Default Title","offer_id":56119910170916,"sku":"SENL-30CD-OL","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MURALE_SENVILLE_LETO_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_6e164e02-6e63-47bb-9840-7239f9f76e8a.png?v=1789049872","url":"https:\/\/airgreen.ca\/en\/products\/mini-split-senville-leto-30000-btu-montreal-laval-rive-sud","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}