{"product_id":"mini-split-senville-leto-36000-btu-montreal-laval-rive-sud","title":"SENVILLE LETO Mini-Split | 36000 BTU | Montréal, Laval, South Shore","description":"\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003e36,000 BTU in a single wall-mounted unit: a solution that requires as much attention to sizing as to installation\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e36,000 BTU SENVILLE LETO\u003c\/strong\u003e is not a mini-split intended for a small bedroom or enclosed office. With a rated capacity of \u003cstrong\u003e36,000 BTU\/h\u003c\/strong\u003e, an indoor unit nearly 50 inches wide, a \u003cstrong\u003e208\/230 V\u003c\/strong\u003e power supply, and \u003cstrong\u003e3\/8 in – 5\/8 in\u003c\/strong\u003e refrigerant piping, this is a wall-mounted heat pump designed for much larger spaces.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, this type of capacity makes the most sense in a \u003cstrong\u003elarge open-concept area, business, workshop, large basement, loft, or residential space with a high heating or cooling load\u003c\/strong\u003e. In Greater Montreal, however, the question is never simply whether 36,000 BTU is “enough.” We must determine whether this capacity can be distributed properly throughout the building and whether the heating performance meets the homeowner’s expectations during Quebec winters.\u003c\/p\u003e\n\u003cp\u003eThe configuration offered on our site uses the \u003cstrong\u003eSENL-36CD-OL\u003c\/strong\u003e outdoor unit and the \u003cstrong\u003eSENL-36CD-ILL\u003c\/strong\u003e indoor unit, associated with \u003cstrong\u003eAHRI 215735293\u003c\/strong\u003e. Senville documentation identifies the technical family under model \u003cstrong\u003eSENL-36CD-L\u003c\/strong\u003e and confirms that it is a \u003cstrong\u003e36,000 BTU LETO mini-split air conditioner and heat pump\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis precision is useful when a homeowner compares several documents: the suffixes may distinguish the indoor and outdoor components, while the general documentation groups the system under a series designation.\u003c\/p\u003e\n\u003ch3\u003eThe essential features of the 36,000 BTU SENVILLE LETO\u003c\/h3\u003e\n\u003cp\u003eThe official technical table on page 4 of the brochure provides a much more precise overview of the unit:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eRated cooling capacity: 36,000 BTU\/h\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCooling range: 2,900 to 36,200 BTU\/h\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRated heating capacity: 36,000 BTU\/h\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeating range: 3,600 to 36,600 BTU\/h\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSEER2: 18\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEER2: 9\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHSPF2 Region 4: 8.5\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHSPF2 Region 5: 6.8\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCOP listed: 2.82\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePower supply: 208\/230 V, single-phase, 60 Hz\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMCA: 33 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum protection: 35 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003erefrigerant: R-454B\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003erefrigerant precharge: 25 feet\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003econnection wiring: 14\/4 AWG\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese values come directly from the Senville technical table. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe AirGreen listing currently displays certain efficiency values in a concatenated format, including “118.030” for SEER2 and “19.020” for EER2. To avoid any ambiguity, we use the figures clearly presented in the official technical documentation here: \u003cstrong\u003e18 SEER2 and 9 EER2\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eA surprisingly wide modulation range for a 36,000 BTU unit\u003c\/h3\u003e\n\u003cp\u003eMaximum capacity naturally draws attention, but minimum capacity is almost as interesting.\u003c\/p\u003e\n\u003cp\u003eIn cooling mode, the compressor can go down to approximately \u003cstrong\u003e2,900 BTU\/h\u003c\/strong\u003e, according to the documentation. In heating mode, the published range starts at approximately \u003cstrong\u003e3,600 BTU\/h\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis feature is important.\u003c\/p\u003e\n\u003cp\u003eA heat pump with \u003cstrong\u003eDC Inverter\u003c\/strong\u003e technology does not operate constantly at 36,000 BTU. It adjusts its output according to demand. The manufacturer also explains that its Inverter system modulates its operation in real time to maintain the desired temperature without constantly using its maximum capacity. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a large room that requires substantial cooling during a July day but very little during a cool evening, this modulation significantly improves the unit’s operation.\u003c\/p\u003e\n\u003cp\u003eIt also helps avoid an unnecessary succession of starts and stops when the load decreases.\u003c\/p\u003e\n\u003ch3\u003e1,250 to 1,800 sq. ft.: why this recommendation should be interpreted with caution\u003c\/h3\u003e\n\u003cp\u003eSenville presents the LETO 36,000 BTU as suitable for spaces of approximately \u003cstrong\u003e1,250 to 1,800 sq. ft.\u003c\/strong\u003e, particularly large rooms and living areas. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, we use this figure only as an initial guideline.\u003c\/p\u003e\n\u003cp\u003eA wall-mounted mini-split does not have a duct network. Even with a capacity of 36,000 BTU, it cannot efficiently move its air through multiple walls, hallways, and closed doors.\u003c\/p\u003e\n\u003cp\u003eLet’s consider two 1,500-square-foot properties.\u003c\/p\u003e\n\u003cp\u003eThe first is a loft with the kitchen, living room, and dining room combined into a single space. A high-capacity wall-mounted unit may have access to much of the space.\u003c\/p\u003e\n\u003cp\u003eThe second is a bungalow with four bedrooms, several hallways, and doors that are regularly closed. Even if the total square footage is identical, a single 36,000 BTU wall-mounted heat pump does not automatically distribute its 36,000 BTU to each room.\u003c\/p\u003e\n\u003cp\u003eThis is a situation we regularly explain during our assessments of \u003cstrong\u003ewall-mounted heat pumps in Montreal, Laval, Longueuil, and the South Shore\u003c\/strong\u003e: \u003cstrong\u003eheating capacity and air distribution are two different problems\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eA nearly 50-inch-wide unit: its location must be decided before installation\u003c\/h3\u003e\n\u003cp\u003eThe indoor unit measures:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e49.57 in wide × 11.10 in deep × 14.25 in high\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eand weighs approximately \u003cstrong\u003e40.34 lb\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe outdoor unit measures:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e37.24 in × 16.14 in × 31.89 in\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003ewith a weight of \u003cstrong\u003e142.86 lb\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThese dimensions significantly change the installation planning compared with a 9,000 or 12,000 BTU mini-split.\u003c\/p\u003e\n\u003cp\u003eA wall that seems large enough in a photograph can become much more restrictive when we need to plan:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe actual width of the evaporator;\u003c\/li\u003e\n\u003cli\u003ethe required clearances;\u003c\/li\u003e\n\u003cli\u003ethe piping outlet;\u003c\/li\u003e\n\u003cli\u003eaccess for maintenance;\u003c\/li\u003e\n\u003cli\u003ethe direction of the airflow;\u003c\/li\u003e\n\u003cli\u003ethe aesthetics of the installation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe outdoor unit's weight is also significant. At nearly \u003cstrong\u003e143 lb\u003c\/strong\u003e, the choice of a wall bracket or ground stand must be suitable for this equipment category.\u003c\/p\u003e\n\u003cp\u003eA verified buyer quoted in the Senville brochure specifically points out that the unit is bulky, requires considerable space, and that the lines are relatively difficult to bend, while also noting that the unit performs as expected. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis is practical feedback that reflects an installation reality: \u003cstrong\u003ea 36,000 BTU heat pump is not handled like a small wall-mounted unit\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003e3\/8-inch – 5\/8-inch piping: a major detail on the job site\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen configuration indicates 3\/8-inch – 5\/8-inch piping.\u003c\/p\u003e\n\u003cp\u003eWith a 5\/8-inch gas line, bends, changes in direction, and tight passages require more planning. This becomes especially important in Montreal plexes, South Shore townhouses, condominiums, or projects where the refrigerant line must go around a door, window, or balcony.\u003c\/p\u003e\n\u003cp\u003eThe documentation also indicates that the unit is \u003cstrong\u003eprecharged for 25 feet of piping\u003c\/strong\u003e. For a 50-foot set, Senville specifies that an additional R-454B charge must be added on site by the installer. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWe therefore need to know the actual line-set length before commissioning.\u003c\/p\u003e\n\u003cp\u003eThis is not merely a matter of the amount of copper. A professional installation requires proper work on the connections, circuit preparation, leak testing, and commissioning according to the manufacturer's specifications.\u003c\/p\u003e\n\u003ch3\u003eR-454B: the refrigerant generation used by this LETO\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSENVILLE LETO 36,000 BTU uses R-454B\u003c\/strong\u003e. The technical table also confirms a factory charge intended for 25 feet. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis information must be taken into consideration during installation and service, particularly because the equipment, work procedures, and handling of the refrigeration circuit must correspond to the refrigerant used by the system.\u003c\/p\u003e\n\u003cp\u003eFor a customer, the key point is simpler: this is not an older model that uses a previous-generation refrigerant. The technician must therefore use the appropriate methods and tools.\u003c\/p\u003e\n\u003ch3\u003e33 A MCA and 35 A maximum protection: check the electrical system before the project begins\u003c\/h3\u003e\n\u003cp\u003eA 36,000 BTU mini-split requires a significantly larger electrical circuit than a lower-capacity wall-mounted unit.\u003c\/p\u003e\n\u003cp\u003eFor the LETO:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMCA: 33 A\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eMaximum protection: 35 A\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe documentation and the AirGreen listing agree on these values. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWe therefore check the available power supply before installation.\u003c\/p\u003e\n\u003cp\u003eA common mistake is to order a heat pump assuming that the circuit from an older, smaller unit can be reused directly. If the old unit was 12,000 or 18,000 BTU, the existing circuit may not meet the new system’s electrical requirements.\u003c\/p\u003e\n\u003cp\u003eThis preliminary check prevents us from arriving on-site with a heat pump ready to be installed when the electrical circuit needs to be modified.\u003c\/p\u003e\n\u003ch3\u003e882.9 CFM in Turbo: why airflow matters on a unit this large\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer’s table provides four indoor airflow rates:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e882.9 CFM in Turbo\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e732.8 CFM at high speed\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e518.0 CFM at medium speed\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e400.2 CFM at low speed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe associated sound pressure levels are:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e56.5 dB(A) in Turbo\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e50.5 dB(A) at high speed\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e44.5 dB(A) at medium speed\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e34 dB(A) at low speed\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe AirGreen listing currently displays a CFM field as “1883,” which does not match the indoor airflow detailed in the brochure. For a technical comparison, we therefore use the four airflow rates published in the official table.\u003c\/p\u003e\n\u003cp\u003eAn airflow of nearly \u003cstrong\u003e883 CFM\u003c\/strong\u003e also explains why positioning the indoor unit is so important. At high speed, the air movement is considerable.\u003c\/p\u003e\n\u003cp\u003eInstalling such a unit too close to a living area or directly facing an occupied zone can create a draft-like sensation. The goal is to use the airflow to distribute the temperature throughout the room, not to direct the flow constantly toward occupants.\u003c\/p\u003e\n\u003ch3\u003e34 dB(A) minimum, but 56.5 dB(A) in Turbo\u003c\/h3\u003e\n\u003cp\u003eSenville describes the system as capable of operating at up to \u003cstrong\u003e34 dB(A)\u003c\/strong\u003e on the quietest indoor setting. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis figure is useful, but it should be presented alongside the full sound range.\u003c\/p\u003e\n\u003cp\u003eAt full fan speed, the unit reaches \u003cstrong\u003e56.5 dB(A)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eFor a 36,000 BTU heat pump intended for a large open area, this behavior is consistent with the required airflow. A room that requires substantial capacity needs a great deal of air to be moved.\u003c\/p\u003e\n\u003cp\u003eThe outdoor unit is rated at \u003cstrong\u003e61.4 dB(A)\u003c\/strong\u003e with a maximum outdoor airflow of \u003cstrong\u003e2,235.3 CFM\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIn a dense environment in Montreal or a narrow yard in Longueuil, we therefore take into account the condenser’s location, reflective surfaces, nearby windows, and potential vibrations.\u003c\/p\u003e\n\u003ch3\u003eA dehumidification capacity of 4.9 L\/h\u003c\/h3\u003e\n\u003cp\u003eThe documentation indicates moisture removal of up to \u003cstrong\u003e4.9 liters per hour\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor large open areas, this feature can make a significant contribution to comfort during hot and humid periods.\u003c\/p\u003e\n\u003cp\u003eThe temperature shown on the thermostat does not tell the whole story. A space at 23 °C with high indoor humidity can remain uncomfortable.\u003c\/p\u003e\n\u003cp\u003eThe compressor’s modulation capability is useful here: when properly sized, the system can maintain more stable operation and help control humidity rather than operating only in very short cycles.\u003c\/p\u003e\n\u003ch2\u003eHeating in Quebec: what the LETO 36,000 BTU can actually deliver\u003c\/h2\u003e\n\u003ch3\u003eHeating advertised down to -15 °C\u003c\/h3\u003e\n\u003cp\u003eSenville’s official documentation clearly presents this model as a unit offering \u003cstrong\u003eheating down to -15 °C\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis information should be emphasized because the LETO 36,000 BTU is not presented as an \u003cstrong\u003eENERGY STAR Cold Climate\u003c\/strong\u003e heat pump.\u003c\/p\u003e\n\u003cp\u003eThe AirGreen specifications confirm:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eENERGY STAR: No\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eENERGY STAR Cold Climate: No\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis does not mean that the unit cannot heat efficiently during a large portion of the winter. Rather, it means that it should not be compared directly with a model specifically designed to maintain high capacity during extreme temperatures.\u003c\/p\u003e\n\u003ch3\u003eAirGreen’s published low-temperature capacities\u003c\/h3\u003e\n\u003cp\u003eOur product page provides several particularly useful performance points:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e24,600 BTU\/h at -8 °C\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e21,400 BTU\/h at -15 °C\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003e11,200 BTU\/h at -25 °C\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThese figures clearly show the decrease in capacity as the outdoor temperature drops.\u003c\/p\u003e\n\u003cp\u003eAt -15 °C, for example, the available \u003cstrong\u003e21,400 BTU\/h\u003c\/strong\u003e represents approximately 59% of the 36,000 BTU rated capacity.\u003c\/p\u003e\n\u003cp\u003eAt -25 °C, the indicated \u003cstrong\u003e11,200 BTU\/h\u003c\/strong\u003e represents approximately 31% of the rated capacity.\u003c\/p\u003e\n\u003cp\u003eThis is probably the most important information to understand before using this system as the primary heating source.\u003c\/p\u003e\n\u003cp\u003eA homeowner may see “36,000 BTU” and assume that this capacity is available regardless of the outdoor temperature. In practice, a heat pump’s capacity changes with conditions.\u003c\/p\u003e\n\u003ch3\u003eWhy a supplementary heating system may still be necessary\u003c\/h3\u003e\n\u003cp\u003eIn a large commercial room or residential space that genuinely requires 30,000 to 36,000 BTUs on the coldest days, a capacity of \u003cstrong\u003e21,400 BTU at -15 °C\u003c\/strong\u003e may not be sufficient on its own.\u003c\/p\u003e\n\u003cp\u003eThe existing electric heating can then supplement the heat pump.\u003c\/p\u003e\n\u003cp\u003eThis combination can make perfect sense if the LETO meets a large portion of the heating needs during the fall, spring, and milder winter periods, while a supplementary source comes into play during the coldest temperatures.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, we prefer to explain this reality before installation rather than promise that a 36,000 BTU unit will automatically replace all existing heating systems.\u003c\/p\u003e\n\u003ch3\u003eIs the 36,000 BTU LETO suitable for Montreal, Laval, and the South Shore?\u003c\/h3\u003e\n\u003cp\u003eYes, for the right project.\u003c\/p\u003e\n\u003cp\u003eWe would consider it especially for a \u003cstrong\u003elarge open area\u003c\/strong\u003e, a business, a workshop, a substantial basement, or an area where 36,000 BTU cooling capacity is the priority.\u003c\/p\u003e\n\u003cp\u003eWe would be more cautious if the owner is primarily looking for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eprimary heating at very low temperatures;\u003c\/li\u003e\n\u003cli\u003ean ENERGY STAR Cold Climate certification;\u003c\/li\u003e\n\u003cli\u003eeligibility for a subsidy linked to this certification;\u003c\/li\u003e\n\u003cli\u003ehigh capacity maintained during extreme cold spells.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe AirGreen product sheet currently shows \u003cstrong\u003eno LogisVert subsidy amount\u003c\/strong\u003e for this combination and indicates that the unit is not ENERGY STAR certified. We therefore recommend \u003cstrong\u003enot including a subsidy in the net-price calculation until eligibility applicable at the time of purchase has been confirmed\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eWiFi, Alexa, and remote control\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen product sheet indicates that \u003cstrong\u003eWiFi is included\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe Senville documentation also confirms \u003cstrong\u003eAlexa\u003c\/strong\u003e compatibility and the ability to use an app to change settings and schedule temperatures remotely. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a large commercial space or workshop, this feature can be particularly convenient.\u003c\/p\u003e\n\u003cp\u003eThe manager can adjust the temperature before occupants arrive, change schedules, or check settings without having to be physically in front of the remote control.\u003c\/p\u003e\n\u003ch3\u003eAutomatic vertical and horizontal louvers\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen product sheet confirms \u003cstrong\u003eautomatic vertical and horizontal louver control\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eOn a unit with such a high airflow rate, this is not merely a comfort feature.\u003c\/p\u003e\n\u003cp\u003eAirflow direction directly affects how the 36,000 BTUs are distributed throughout the room. We therefore use louver movement in addition to proper indoor-unit placement.\u003c\/p\u003e\n\u003cp\u003eHowever, even the best air-sweeping system cannot effectively get around several partitions. That is why the building layout remains central when choosing a single-zone mini-split.\u003c\/p\u003e\n\u003ch3\u003eWarranty: a difference to verify before purchase\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen product sheet shows:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e10-year compressor – 10-year parts – 0-year labor\u003c\/strong\u003e, with additional warranty coverage possibly available.\u003c\/p\u003e\n\u003cp\u003eThe Senville brochure provided states:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5-year compressor – 5-year parts\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe same documentation specifies that installation by an authorized technician is required and that professional installation is necessary to maintain coverage and ensure compliant operation. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis difference between the manufacturer's basic warranty and the warranty advertised by AirGreen must be confirmed according to the applicable program, product registration, and sales terms at the time of ordering.\u003c\/p\u003e\n\u003cp\u003eWe always recommend that the customer keep:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe invoice;\u003c\/li\u003e\n\u003cli\u003eserial numbers;\u003c\/li\u003e\n\u003cli\u003eproof of installation;\u003c\/li\u003e\n\u003cli\u003ewarranty registration information;\u003c\/li\u003e\n\u003cli\u003ethe documents associated with any additional warranty.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhat we verify before installing a 36,000 BTU LETO\u003c\/h3\u003e\n\u003cp\u003eWith a heat pump of this capacity, our preparation focuses on several elements that can completely change the final result.\u003c\/p\u003e\n\u003cp\u003eWe first validate the \u003cstrong\u003ethermal load and space configuration\u003c\/strong\u003e. Next come the evaporator location, airflow path, and the possibility of running the \u003cstrong\u003e3\/8 in – 5\/8 in\u003c\/strong\u003e lines to the condenser.\u003c\/p\u003e\n\u003cp\u003eWe also confirm the electrical circuit corresponding to the \u003cstrong\u003e33 A MCA and 35 A MOP\u003c\/strong\u003e, then determine an outdoor location sturdy enough for a unit weighing nearly \u003cstrong\u003e143 lb\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eIn winter, we also plan the space around the condenser so that snow, ice, and water from defrosting do not interfere with its operation.\u003c\/p\u003e\n\u003cp\u003eThese are less visible elements than a SEER2 rating or a Wi-Fi function, but they are often what determines whether an installation will remain practical for many years.\u003c\/p\u003e\n\u003ch3\u003eThe SENVILLE LETO 36,000 BTU in brief\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eSENVILLE LETO SENL-36CD-OL \/ SENL-36CD-ILL\u003c\/strong\u003e is clearly intended for projects where high cooling capacity and strong airflow are required in a single zone.\u003c\/p\u003e\n\u003cp\u003eIts main technical specifications are solid and easy to identify: \u003cstrong\u003e36,000 BTU\u003c\/strong\u003e, \u003cstrong\u003e18 SEER2\u003c\/strong\u003e, \u003cstrong\u003eDC Inverter\u003c\/strong\u003e technology, \u003cstrong\u003eR-454B\u003c\/strong\u003e, Wi-Fi, Alexa compatibility, substantial modulation, \u003cstrong\u003e3\/8 in – 5\/8 in\u003c\/strong\u003e piping, and a 208\/230 V power supply.\u003c\/p\u003e\n\u003cp\u003eIts main limitation for the Quebec market is also clear: it is not an \u003cstrong\u003eENERGY STAR Cold Climate\u003c\/strong\u003e model, and its heating capacity decreases considerably at very low temperatures.\u003c\/p\u003e\n\u003cp\u003eFor some projects, this compromise is perfectly reasonable. For others, particularly when winter heating is the absolute priority, we may recommend a heat pump with higher low-temperature capacity.\u003c\/p\u003e\n\u003cp\u003eAt \u003cstrong\u003eAirGreen\u003c\/strong\u003e, our job is precisely to make this distinction before the equipment is installed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFor a SENVILLE LETO 36,000 BTU installation in Montreal, Laval, Longueuil, on the South Shore, the North Shore, or elsewhere in Greater Montreal, contact AirGreen. We can verify the sizing, electrical supply, unit locations, and building configuration to prepare a quote tailored to the project.\u003c\/strong\u003e\u003c\/p\u003e","brand":"Senville","offers":[{"title":"Default Title","offer_id":56119910400292,"sku":"SENL-36CD-OL","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/THERMOPOMPE_MURALE_SENVILLE_LETO_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_f2db75ca-9675-4843-b719-d4025b9e9aae.png?v=1789049878","url":"https:\/\/airgreen.ca\/en\/products\/mini-split-senville-leto-36000-btu-montreal-laval-rive-sud","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}