{"product_id":"mini-split-york-serie-x-23-seer-24000-btu","title":"YORK X Series Mini Split 23 SEER | 24000 BTU","description":"\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eA large wall-mounted heat pump that deserves to be evaluated based on its actual capabilities, not just the “24,000 BTU” label\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYORK X Series 23 SEER Mini Split | 24000 BTU\u003c\/strong\u003e is intended for a very different type of project than a small wall-mounted heat pump installed solely in a bedroom. With its 42-inch indoor unit, airflow of up to 706 CFM, and broad modulation range, this combination may be suitable for a \u003cstrong\u003elarge open-concept area, a floor, a small commercial space, a living room connected to a kitchen, or a residential area with a significant heating load\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, we pay particular attention to 24,000 BTU models because they are often chosen too quickly. Some homeowners select them based solely on floor area; others think that a larger unit will necessarily provide better comfort. In practice, the right selection depends on the building's layout, insulation, sun exposure, windows, ceilings, air circulation, and actual heating demand.\u003c\/p\u003e\n\u003cp\u003eFor this X Series, the model numbers are precise: \u003cstrong\u003eDHX24NWB21S for the wall-mounted indoor unit\u003c\/strong\u003e and \u003cstrong\u003eDHX24CSB21S for the outdoor unit\u003c\/strong\u003e. YORK clearly identifies this pair as the 24K BTU\/h, 208\/230 V configuration in its X Series. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHowever, it is important to understand a particular feature of the nomenclature. The product line is called \u003cstrong\u003e“X Series 23 SEER”\u003c\/strong\u003e, but this figure represents the maximum performance of the family and not necessarily that of every capacity. For the DHX24 model specifically, the brochure indicates \u003cstrong\u003eSEER 20, EER 12.5, and HSPF 10\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis is exactly the kind of detail we verify before comparing two HVAC systems. A general commercial designation never replaces reviewing the data sheet corresponding to the two model numbers actually installed.\u003c\/p\u003e\n\u003ch3\u003eYORK DHX24NWB21S + DHX24CSB21S: essential technical specifications\u003c\/h3\u003e\n\u003cp\u003eThe model presented on our AirGreen page is associated with reference \u003cstrong\u003eAHRI 8578581\u003c\/strong\u003e and operates with \u003cstrong\u003eR410A\u003c\/strong\u003e. The 2020 YORK brochure provides particularly detailed data for this combination.\u003c\/p\u003e\n\u003cp\u003eThe key specifications are:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIndoor unit: DHX24NWB21S\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOutdoor unit: DHX24CSB21S\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePower supply: 208\/230 V, 1 phase, 60 Hz\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eYORK published rated cooling capacity: 22,000 BTU\/h\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCooling modulation range: 6,824 to 27,296 BTU\/h\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRated heating capacity: 23,000 BTU\/h\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeating modulation range: 6,824 to 30,708 BTU\/h\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEER: 12.5\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSEER: 20 for this specific combination\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHSPF: 10\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMCA: 20 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMOCP\/MOP: 30 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIndoor airflow: 706 \/ 647 \/ 588 \/ 530 CFM\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIndoor sound pressure: 48 \/ 44 \/ 40 \/ 36 dB(A)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOutdoor sound pressure: 59 dB(A)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePiping: 1\/4 in liquid and 5\/8 in gas\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDrain: 5\/8 in\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum piping length: 82 ft \/ 25 m\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum elevation difference: 33 ft \/ 10 m\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeating range: down to -20 °C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCooling range: down to -18 °C outdoor low-temperature side\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWi-Fi available with CS532AH adapter\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese figures provide a much more useful picture of the unit’s potential behavior than a simple “24,000 BTU.”\u003c\/p\u003e\n\u003ch3\u003eWhy does YORK call it 24,000 BTU when the brochure indicates 22,000 BTU nominal cooling capacity?\u003c\/h3\u003e\n\u003cp\u003eThis difference deserves a clear explanation.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eDHX24\u003c\/strong\u003e belongs to YORK’s 24K commercial category, but the nominal cooling capacity listed in the manufacturer’s table is \u003cstrong\u003e22,000 BTU\/h\u003c\/strong\u003e. However, its maximum modulated capacity reaches \u003cstrong\u003e27,296 BTU\/h\u003c\/strong\u003e in cooling mode. In heating mode, it is nominally \u003cstrong\u003e23,000 BTU\/h\u003c\/strong\u003e and can reach \u003cstrong\u003e30,708 BTU\/h\u003c\/strong\u003e under the conditions defined by the manufacturer. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis does not mean there is a product error. HVAC equipment families are commonly grouped by capacity classes, while the certified data for a specific combination may differ from the round value used in its commercial designation.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, when we size a \u003cstrong\u003ewall-mounted heat pump in Montreal, Laval, Longueuil, on the North Shore or the South Shore\u003c\/strong\u003e, we therefore consider the certified capacity and its modulation range, not just the number shown in the product name.\u003c\/p\u003e\n\u003ch3\u003eModulation that genuinely changes the unit’s behavior\u003c\/h3\u003e\n\u003cp\u003eThe YORK X Series 24K’s modulation range is noteworthy because it can drop to approximately \u003cstrong\u003e6,824 BTU\/h\u003c\/strong\u003e while also being able to significantly exceed its nominal capacity at a given moment.\u003c\/p\u003e\n\u003cp\u003eA properly sized Inverter unit therefore does not constantly operate at 22,000 or 24,000 BTU. As the room approaches the desired temperature, the compressor can reduce its output to better track the load.\u003c\/p\u003e\n\u003cp\u003eYORK explains that its mini-split systems specifically use this refrigerant flow modulation to adjust capacity to the zone’s demand. This technology also helps limit the temperature fluctuations associated with systems that constantly start and stop. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIn a large open-concept area in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, for example, demand can be high on a July afternoon when the sun shines directly through several windows, then drop sharply after sunset. The advantage of the Inverter compressor is precisely that it does not handle these two situations in the same way.\u003c\/p\u003e\n\u003ch3\u003eA maximum airflow of 706 CFM: the positioning of the indoor module becomes crucial\u003c\/h3\u003e\n\u003cp\u003eThe DHX24NWB21S provides four airflow levels: \u003cstrong\u003e706, 647, 588 and 530 CFM\u003c\/strong\u003e. YORK indicates corresponding sound levels of \u003cstrong\u003e48, 44, 40 and 36 dB(A)\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWith airflow of this magnitude, the location of the indoor unit must be carefully considered.\u003c\/p\u003e\n\u003cp\u003eWe avoid sending the airflow from a 24K unit directly toward a sofa, dining table, or workstation located a short distance away whenever possible. The goal is instead to take advantage of the room's length so that the air gradually mixes before returning to the evaporator.\u003c\/p\u003e\n\u003cp\u003eIn our \u003cstrong\u003eHVAC projects in Montreal and the Montérégie\u003c\/strong\u003e, a common mistake is to select the only wall where installation seems easy without analyzing the airflow path. The system can then produce enough BTUs while creating an uncomfortable zone directly in front of the unit and a less uniform temperature at the other end.\u003c\/p\u003e\n\u003ch3\u003eA 42-inch indoor unit designed to move a lot of air\u003c\/h3\u003e\n\u003cp\u003eThe indoor module measures \u003cstrong\u003e42 × 13 × 10 in\u003c\/strong\u003e, or approximately 1,078 × 325 × 246 mm. Its net weight is approximately 38 lb. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe DHX24CSB21S outdoor unit is larger: approximately \u003cstrong\u003e39 × 31 × 17 in\u003c\/strong\u003e, or 980 × 790 × 427 mm. YORK indicates a net weight of approximately 142 lb and an outdoor sound pressure level of \u003cstrong\u003e59 dB(A)\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThese dimensions have a direct impact on a \u003cstrong\u003eheat pump installation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eOn a narrow lot in Montreal, a condo balcony in Laval, or a home's side yard on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, sufficient space must be allowed for clearances, future servicing of the unit, air discharge, and snow management in winter.\u003c\/p\u003e\n\u003cp\u003eThe choice of outdoor support also matters. The unit must not be positioned where ice, snow, or water from a roof could regularly fall onto the appliance.\u003c\/p\u003e\n\u003ch3\u003eHeating Down to -20 °C: The Minimum Temperature Does Not Tell the Whole Story\u003c\/h3\u003e\n\u003cp\u003eThe YORK brochure indicates a heating operating range of \u003cstrong\u003e-20 °C to 24 °C\u003c\/strong\u003e for the DHX24CSB21S. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eOur AirGreen specifications also provide additional low-temperature capacity data: approximately \u003cstrong\u003e20,000 BTU at -8 °C\u003c\/strong\u003e, \u003cstrong\u003e19,800 BTU at -15 °C\u003c\/strong\u003e, and a displayed maximum value of \u003cstrong\u003e11,000 BTU at -20 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThese figures show why we never evaluate a heat pump solely based on the statement “heats down to -20 °C.”\u003c\/p\u003e\n\u003cp\u003eThe more important question is: \u003cstrong\u003ehow much heating capacity remains when it is actually cold?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA unit may continue operating at -20 °C while providing less capacity than at 0 °C. If the home’s heat loss exceeds the heat pump’s output at that temperature, a supplemental heating source must take over or assist with heating.\u003c\/p\u003e\n\u003cp\u003eThis distinction is particularly important for homeowners in \u003cstrong\u003eLaval, Terrebonne, Blainville, Repentigny, Longueuil, Boucherville, and other areas of Greater Montreal\u003c\/strong\u003e, where temperatures can drop well below -15 °C.\u003c\/p\u003e\n\u003ch3\u003e1\/4 in. – 5\/8 in.: Piping to Confirm Before Any Replacement\u003c\/h3\u003e\n\u003cp\u003eThe DHX24 uses a \u003cstrong\u003e1\/4 in.\u003c\/strong\u003e liquid line and a \u003cstrong\u003e5\/8 in.\u003c\/strong\u003e gas line. The brochure allows for a maximum length of \u003cstrong\u003e82 feet\u003c\/strong\u003e and a maximum elevation difference of \u003cstrong\u003e33 feet\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThe 5\/8 in. diameter on the gas side is an important consideration when replacing a unit.\u003c\/p\u003e\n\u003cp\u003eWe often encounter properties where the old unit used different piping. A homeowner may then want to keep the existing lines to reduce the amount of work. This is not automatically possible.\u003c\/p\u003e\n\u003cp\u003eA 24,000 BTU heat pump from another manufacturer does not necessarily use the same diameters. We therefore check the existing lines before confirming that they can be reused.\u003c\/p\u003e\n\u003cp\u003eThe savings from keeping unsuitable piping are never worth the potential problems with refrigerant flow, oil return, and compressor operation.\u003c\/p\u003e\n\u003ch3\u003eMCA 20 A and MOP 30 A: What This Means for the Electrical Circuit\u003c\/h3\u003e\n\u003cp\u003eThe YORK X Series 24K operates on a \u003cstrong\u003e208\/230 V single-phase power supply\u003c\/strong\u003e. Its manufacturer’s specifications indicate an \u003cstrong\u003eMCA of 20 A\u003c\/strong\u003e and a maximum protection rating \u003cstrong\u003eMOCP of 30 A\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eMCA is the minimum circuit ampacity to consider when supplying power to the equipment. MOP\/MOCP, meanwhile, determines the maximum permitted overcurrent protection according to the manufacturer’s data.\u003c\/p\u003e\n\u003cp\u003eDuring an AirGreen installation, we therefore do not limit ourselves to asking whether the customer “has 220 V.” The circuit type, its rating, its breaker, and the nameplate specifications of the actual unit delivered must match.\u003c\/p\u003e\n\u003cp\u003eThis verification becomes particularly important in some older homes in \u003cstrong\u003eMontréal\u003c\/strong\u003e or \u003cstrong\u003eLaval\u003c\/strong\u003e, where several electrical additions may have been made over the years.\u003c\/p\u003e\n\u003ch3\u003eAutomatic Louvers and Airflow Control\u003c\/h3\u003e\n\u003cp\u003eYORK’s X Series documentation indicates several functions related to air distribution, including automatic vertical and horizontal movement, according to the range’s function chart. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eOur AirGreen product sheet therefore correctly states:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVertical louver: automatic\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eHorizontal louver: automatic\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eFor a unit capable of exceeding 700 CFM, this feature is especially useful.\u003c\/p\u003e\n\u003cp\u003eHorizontal movement can help distribute air throughout an open area rather than concentrating the entire airflow in one direction. Vertical movement makes it easier to adjust air distribution depending on whether the system is being used for cooling or heating.\u003c\/p\u003e\n\u003cp\u003eHowever, adjusting the louvers cannot correct poor placement. If a heat pump is installed in a hallway with the expectation that it will heat three bedrooms evenly while their doors remain closed, the problem is not the remote-control setting: it is the project design.\u003c\/p\u003e\n\u003ch3\u003eOptional Wi-Fi with the CS532AH adapter\u003c\/h3\u003e\n\u003cp\u003eThe X Series can be controlled through the \u003cstrong\u003eEWPE Smart App\u003c\/strong\u003e, but connectivity requires the \u003cstrong\u003eCS532AH adapter\u003c\/strong\u003e for the P and X Series. YORK also specifies that the \u003cstrong\u003eDRCPX\u003c\/strong\u003e wireless remote control comes standard with the X Series. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWe like to clarify this distinction before installation because “Wi-Fi compatible” and “built-in Wi-Fi” do not mean the same thing.\u003c\/p\u003e\n\u003cp\u003eA homeowner who wants to schedule or control their unit remotely must plan for the necessary module rather than assume that the function is already installed in the wall-mounted air conditioner.\u003c\/p\u003e\n\u003ch3\u003eConstruction, Defrosting, and Practical Features of the X Series\u003c\/h3\u003e\n\u003cp\u003eYORK presents the X Series as an Inverter heat pump equipped with a \u003cstrong\u003erugged steel chassis\u003c\/strong\u003e, a corrosion-resistant coating, and quiet operation. The manufacturer also mentions a demand-initiated defrost strategy to limit unnecessary energy consumption associated with defrosting. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eDefrosting is particularly relevant in Québec.\u003c\/p\u003e\n\u003cp\u003eWhen the outdoor unit operates in heating mode, the outdoor coil may accumulate frost. The system must periodically reverse its cycle to clear the coil. The frequency depends on outdoor conditions, particularly temperature and humidity.\u003c\/p\u003e\n\u003cp\u003eA heat pump that defrosts in winter does not necessarily indicate a problem. However, excessive ice accumulation that does not disappear, abnormally frequent cycles, or a unit with obstructed winter drainage warrant an inspection.\u003c\/p\u003e\n\u003ch2\u003eWhat we verify at AirGreen before recommending this 24K YORK in Montréal, Laval, Longueuil, the North Shore, or the South Shore\u003c\/h2\u003e\n\u003ch3\u003eA 24K capacity is not a shortcut to avoid a load calculation\u003c\/h3\u003e\n\u003cp\u003eA large heat pump does not compensate for poor selection.\u003c\/p\u003e\n\u003cp\u003eFor example, we encounter open-plan ground floors where a capacity in this category makes perfect sense: large area, numerous windows, an open kitchen, and strong solar exposure. In other properties, the same unit would be oversized despite a similar area because the building’s insulation and orientation are different.\u003c\/p\u003e\n\u003cp\u003eWe therefore analyze the room as a whole: building envelope, windows, orientation, floors, air volume, communication between zones, and the system’s actual use.\u003c\/p\u003e\n\u003cp\u003eThis is particularly relevant for a model whose range goes down to approximately \u003cstrong\u003e6,824 BTU\/h\u003c\/strong\u003e. This modulation provides flexibility, but it does not make oversizing inconsequential.\u003c\/p\u003e\n\u003ch3\u003eAn important nuance regarding ENERGY STAR\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen specification sheet currently provided classifies this model as \u003cstrong\u003eENERGY STAR: No\u003c\/strong\u003e and \u003cstrong\u003eENERGY STAR Cold Climate: No\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe November 2020 YORK brochure nevertheless contains a different note: it states that all models in this series presented in the table were ENERGY STAR, except the 18K DHX18 models. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis difference illustrates why we always distinguish between \u003cstrong\u003ea former manufacturer certification\u003c\/strong\u003e and \u003cstrong\u003ea device’s current eligibility for a Québec program\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eFor a grant application in 2026, we recommend checking the exact combination against the current lists and criteria rather than relying on the logo appearing in a 2020 brochure.\u003c\/p\u003e\n\u003cp\u003eThe attached brochure is indeed dated \u003cstrong\u003eNovember 2020\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eSEER 23 or SEER 20: once again, the two figures do not describe the same thing\u003c\/h3\u003e\n\u003cp\u003eThe family title indicates \u003cstrong\u003e23 SEER\u003c\/strong\u003e because the X Series reaches up to 23 SEER in certain capacities. The brochure also specifies that the X Series is a range “up to 23 SEER.” \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor the \u003cstrong\u003eDHX24NWB21S + DHX24CSB21S\u003c\/strong\u003e, however, the published rating is \u003cstrong\u003e20 SEER\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor us, this is not an administrative detail. When a customer compares a YORK heat pump with another brand, the performance of the \u003cstrong\u003eexact combinations\u003c\/strong\u003e must be compared; otherwise, two products may appear identical on paper even though they are not.\u003c\/p\u003e\n\u003cp\u003eThe same caution applies to the newer \u003cstrong\u003eSEER2 and HSPF2\u003c\/strong\u003e ratings: an older brochure using SEER\/HSPF should not be arbitrarily converted into SEER2\/HSPF2 values.\u003c\/p\u003e\n\u003ch3\u003eWarranty: understanding the difference between the standard warranty and the registered extended warranty\u003c\/h3\u003e\n\u003cp\u003eOur AirGreen listing presents this model with a warranty of \u003cstrong\u003e10 years on the compressor, 10 years on parts, 0 years on labor\u003c\/strong\u003e, with the possibility of additional coverage.\u003c\/p\u003e\n\u003cp\u003eYORK documentation explains that the standard warranty for this generation was \u003cstrong\u003e7 years on the compressor and 5 years on parts\u003c\/strong\u003e, and that eligible residential registration allowed it to be extended to \u003cstrong\u003e10 years on the compressor and 10 years on parts\u003c\/strong\u003e. A 10-year labor warranty option was also available subject to additional conditions. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWe therefore always recommend keeping the invoice, serial numbers, and registration confirmation after an \u003cstrong\u003eHVAC installation\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch3\u003eMaintenance remains important for a large wall-mounted unit\u003c\/h3\u003e\n\u003cp\u003eA unit capable of moving \u003cstrong\u003e706 CFM\u003c\/strong\u003e depends directly on the cleanliness of its heat exchanger, filters, and blower wheel.\u003c\/p\u003e\n\u003cp\u003eOver time, dust can accumulate on the blower wheel. The owner may then gradually notice reduced airflow, a different sound level, or less even distribution throughout the room.\u003c\/p\u003e\n\u003cp\u003eThe condensate drain must also remain clear. In summer, a unit of this capacity can remove a significant amount of moisture from the air. A clogged or improperly sloped drain can cause water to leak indoors.\u003c\/p\u003e\n\u003cp\u003eProfessional \u003cstrong\u003eHVAC maintenance\u003c\/strong\u003e therefore does not consist solely of rinsing the visible filters. Depending on the system’s condition, the evaporator, blower wheel, condensate pan and drainage may require a more thorough inspection and cleaning.\u003c\/p\u003e\n\u003ch3\u003eWhy Have This YORK Installed by AirGreen\u003c\/h3\u003e\n\u003cp\u003eThe YORK Series X 24K has interesting features, but its actual performance depends directly on the installation.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, our work does not stop at mounting the evaporator on the wall. We must verify the capacity, the piping route, the diameter \u003cstrong\u003e1\/4–5\/8\u003c\/strong\u003e, the drain, the electrical supply, the condenser location, the airflow path and the customer’s expectations for winter heating.\u003c\/p\u003e\n\u003cp\u003eWe work daily in the various types of buildings found in \u003cstrong\u003eMontreal, Laval, Longueuil, on the North Shore, the South Shore and in Montérégie\u003c\/strong\u003e: single-family homes, plexes, condos, commercial premises and properties where available space can sometimes make outdoor installation more difficult.\u003c\/p\u003e\n\u003cp\u003eFor this \u003cstrong\u003eYORK Series X Mini Split\u003c\/strong\u003e, we primarily note that it is a 24K-class unit offering a published capacity of \u003cstrong\u003e22,000 BTU\/h in cooling and 23,000 BTU\/h in heating\u003c\/strong\u003e, modulation reaching 27,296 BTU\/h in cooling and 30,708 BTU\/h in heating, a 208\/230 V power supply, an MCA of 20 A, maximum protection of 30 A and 1\/4–5\/8 piping. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eContact AirGreen to confirm whether the YORK Series X 24K is truly suitable for your space\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eYORK Series X 23 SEER | 24000 BTU Mini Split\u003c\/strong\u003e can be a very interesting option for a large area when properly sized. Its inverter technology, modulation range, high airflow, automatic louvers, heating down to -20 °C and optional Wi-Fi give it appreciable versatility.\u003c\/p\u003e\n\u003cp\u003eBut the right question is never simply “Is a 24,000 BTU unit large enough?” Instead, we seek to determine \u003cstrong\u003ewhat capacity your building actually requires and how to install the unit to use that capacity properly\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContact AirGreen for a quote or an assessment of your ductless heat pump project in Montreal, Laval, Longueuil, on the North Shore or South Shore. We can verify whether this YORK Series X matches your heating load, electrical installation and heating expectations before you finalize your choice.\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56120414470436,"sku":"DHX24CSB21S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_MINI_SPLIT_YORK_SERIE_X_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_e5955463-c9ca-406b-9eee-e1653f4c846d.png?v=1789426073","url":"https:\/\/airgreen.ca\/en\/products\/mini-split-york-serie-x-23-seer-24000-btu","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}