{"product_id":"mini-split-york-serie-x-23-seer-9000-btu-115v","title":"YORK X Series Mini Split 23 SEER | 9000 BTU 115V","description":"\u003ch2 class=\"PDq2pG_selectionAnchorContainer\"\u003eA compact, efficient 115 V wall-mounted heat pump, particularly appealing when the electrical supply imposes constraints\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eYORK X Series 23 SEER Mini Split | 9000 BTU 115V\u003c\/strong\u003e occupies a somewhat unique position among wall-mounted heat pumps. Its rated capacity of \u003cstrong\u003e9,000 BTU\/h\u003c\/strong\u003e, \u003cstrong\u003e115 V\u003c\/strong\u003e power supply, and published seasonal efficiency of \u003cstrong\u003e23 SEER\u003c\/strong\u003e make it a suitable solution for small residential areas where installing a much larger unit powered by 208\/230 V would be unnecessary—or sometimes complicated.\u003c\/p\u003e\n\u003cp\u003eThe system consists of the \u003cstrong\u003eDHX09NWB11S\u003c\/strong\u003e indoor unit and the \u003cstrong\u003eDHX09CSB11S\u003c\/strong\u003e outdoor unit. YORK identifies it in its documentation as a wall-mounted inverter heat pump from the \u003cstrong\u003eX Series\u003c\/strong\u003e, designed to heat and cool a single zone. The manufacturer’s brochure also presents the X Series as a range offering up to \u003cstrong\u003e23 SEER\u003c\/strong\u003e, with inverter technology, quiet operation, a rugged steel outdoor chassis, corrosion-resistant coating, and demand-based defrosting. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eAt \u003cstrong\u003eAirGreen Climatisation \u0026amp; Chauffage\u003c\/strong\u003e, we are particularly interested in this type of model for projects where the question is not simply “how many BTUs are needed?” but also: what electrical circuit is available, what is the actual size of the room, where can the outdoor unit be installed, and how much piping will need to be planned?\u003c\/p\u003e\n\u003cp\u003eIn \u003cstrong\u003eMontreal, Laval, Longueuil, on the North Shore and the South Shore\u003c\/strong\u003e, these details often make the difference between a straightforward installation and one that requires electrical work, finish modifications, or a much more complex line-set route.\u003c\/p\u003e\n\u003ch3\u003eKey technical figures for the YORK DHX09NWB11S \/ DHX09CSB11S\u003c\/h3\u003e\n\u003cp\u003eThe YORK brochure provides very precise data for this 115 V combination. The rated cooling capacity is \u003cstrong\u003e9,000 BTU\/h\u003c\/strong\u003e, but the inverter compressor allows modulation from \u003cstrong\u003e2,764 to 10,918 BTU\/h\u003c\/strong\u003e. In heating mode, the rated capacity reaches \u003cstrong\u003e9,900 BTU\/h\u003c\/strong\u003e, with a published modulation range of \u003cstrong\u003e2,081 to 13,989 BTU\/h\u003c\/strong\u003e. The stated efficiency is \u003cstrong\u003e23 SEER\u003c\/strong\u003e, \u003cstrong\u003e10.5 HSPF\u003c\/strong\u003e, and \u003cstrong\u003e13 EER\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a small wall-mounted heat pump, this modulation range is significant. The unit does not need to run continuously at 9,000 BTU. When the heating or cooling load decreases, the inverter can reduce output to maintain a more stable temperature.\u003c\/p\u003e\n\u003cp\u003eThe main technical specifications are as follows:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eIndoor unit: DHX09NWB11S\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOutdoor unit: DHX09CSB11S\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRated cooling capacity: 9,000 BTU\/h\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCooling range: 2,764 to 10,918 BTU\/h\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRated heating capacity: 9,900 BTU\/h\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeating range: 2,081 to 13,989 BTU\/h\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSEER: 23\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEER: 13\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHSPF: 10.5\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRefrigerant: R-410A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePower supply: 115 V, single-phase, 60 Hz\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMCA: 12 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMOCP\/MOP: 20 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRated current in cooling: 6.2 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRated current in heating: 6.2 A\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePiping: 1\/4 in liquid and 3\/8 in gas\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDrain: 5\/8 in\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum piping length: 49.2 ft \/ 15 m\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMaximum elevation difference: 33 ft \/ 10 m\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHeating operating range: down to -20 °C\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCooling operating range: up to 46 °C outdoor temperature\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIndoor sound level: 26 to 43 dB(A)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOutdoor sound level: 53 dB(A)\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eIndoor unit dimensions: approximately 33 × 11 × 8 in\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eOutdoor unit dimensions: approximately 33 × 21 × 12.5 in\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWi-Fi: optional with CS532AH adapter\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDRCPX wireless remote control: included\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese airflow, sound level, dimensions, connection, and operating range values are those published by YORK for the 9,000 BTU 115 V model in the X Series. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eWhy 115 V can really simplify certain projects\u003c\/h3\u003e\n\u003cp\u003eMost wall-mounted heat pumps of comparable capacity that we encounter today are powered by 208\/230 V. The \u003cstrong\u003eDHX09CSB11S operates at 115 V\u003c\/strong\u003e, which can be an advantage in certain buildings where the existing electrical infrastructure limits the options.\u003c\/p\u003e\n\u003cp\u003eThis obviously does not mean that a 115 V appliance can be plugged into just any wall outlet. A \u003cstrong\u003eprofessional HVAC installation\u003c\/strong\u003e must always comply with the manufacturer's electrical specifications, the applicable Code, the required protections, and installation requirements.\u003c\/p\u003e\n\u003cp\u003eHere, YORK specifies a \u003cstrong\u003eminimum circuit ampacity of 12 A\u003c\/strong\u003e and a maximum protection of \u003cstrong\u003e20 A\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIn an older \u003cstrong\u003eMontreal\u003c\/strong\u003e duplex, a condo, a small \u003cstrong\u003eLaval\u003c\/strong\u003e apartment, or a room added on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e, this feature can nevertheless avoid a more complex 240 V configuration when the building conditions permit.\u003c\/p\u003e\n\u003cp\u003eThis is exactly the kind of detail we check before recommending a model: a voltage difference that may seem minor on a specification sheet can have a direct impact on feasibility, cost, and the simplicity of the installation.\u003c\/p\u003e\n\u003ch3\u003e9,000 BTU: a capacity to size according to the room, not solely according to square footage\u003c\/h3\u003e\n\u003cp\u003eA common mistake is to automatically associate a 9,000 BTU capacity with a specific number of square feet.\u003c\/p\u003e\n\u003cp\u003eAt AirGreen, we avoid this shortcut.\u003c\/p\u003e\n\u003cp\u003eTwo rooms of the same size can have completely different heating and cooling loads. We examine in particular:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003einsulation quality;\u003c\/li\u003e\n\u003cli\u003ethe number and size of windows;\u003c\/li\u003e\n\u003cli\u003esolar orientation;\u003c\/li\u003e\n\u003cli\u003ethe floor of the dwelling;\u003c\/li\u003e\n\u003cli\u003eceiling height;\u003c\/li\u003e\n\u003cli\u003eexposure of exterior walls;\u003c\/li\u003e\n\u003cli\u003ethe number of occupants;\u003c\/li\u003e\n\u003cli\u003eheat-generating equipment;\u003c\/li\u003e\n\u003cli\u003eair circulation to adjacent rooms.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA properly sized 9,000 BTU unit can maintain a very stable temperature. The same unit installed in a room with a higher thermal load than its capacity may run continuously without achieving the desired comfort.\u003c\/p\u003e\n\u003cp\u003eThe opposite is not better: an oversized heat pump may reach its setpoint quickly but may not run long enough under certain conditions to provide the best possible dehumidification.\u003c\/p\u003e\n\u003ch3\u003eInverter modulation significantly changes how a 9,000 BTU unit operates\u003c\/h3\u003e\n\u003cp\u003eThe stated minimum cooling capacity of \u003cstrong\u003e2,764 BTU\/h\u003c\/strong\u003e is particularly noteworthy.\u003c\/p\u003e\n\u003cp\u003eSuppose a bedroom or small living room requires high capacity during a very hot day, followed by much less cooling in the evening. Instead of operating only at full capacity before shutting off, the unit can reduce its output.\u003c\/p\u003e\n\u003cp\u003eThe same principle applies to heating, since YORK indicates modulation ranging from \u003cstrong\u003e2,081 to 13,989 BTU\/h\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis wide range helps limit repeated starts and stops when only a small amount of capacity is needed to maintain the setpoint.\u003c\/p\u003e\n\u003cp\u003eThis is one of the factors we consider when comparing an inverter heat pump with an older wall- or window-mounted air conditioner that operates mainly in on\/off mode.\u003c\/p\u003e\n\u003ch3\u003eIndoor operation as quiet as 26 dB(A)\u003c\/h3\u003e\n\u003cp\u003eThe indoor unit offers four published airflow levels: approximately \u003cstrong\u003e400, 288, 241, and 171 CFM\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe sound pressure level varies accordingly between \u003cstrong\u003e43, 38, 32, and 26 dB(A)\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eFor a bedroom, home office, or small living room, this minimum value of \u003cstrong\u003e26 dB(A)\u003c\/strong\u003e is significant. It does not mean that the unit always operates at 26 dB(A), since the fan and compressor adjust to the demand. However, it indicates that at low fan speed, indoor operation can be very quiet.\u003c\/p\u003e\n\u003cp\u003eWe also pay attention to where the unit is installed. Even a quiet system becomes less comfortable if the air is directed straight at the bed, a workstation, or the sofa.\u003c\/p\u003e\n\u003cp\u003eA good installation is therefore not just about finding enough space on the wall. The actual path of the airflow must also be considered.\u003c\/p\u003e\n\u003ch3\u003eA compact unit that makes installation easier in small rooms\u003c\/h3\u003e\n\u003cp\u003eThe indoor unit measures approximately \u003cstrong\u003e33 in. wide, 11 in. deep, and 8 in. high\u003c\/strong\u003e. The outdoor unit is also relatively compact, measuring approximately \u003cstrong\u003e33 × 21 × 12.5 in.\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIn some properties in \u003cstrong\u003eLongueuil\u003c\/strong\u003e, Montréal, or Laval, we have to work around short walls, high windows, closets, existing pipes, or façade constraints. These dimensions are therefore useful as early as the estimation stage.\u003c\/p\u003e\n\u003cp\u003eWe want to leave enough space around the indoor unit to allow proper air intake and make \u003cstrong\u003eHVAC maintenance\u003c\/strong\u003e accessible. Outdoors, we must also respect the clearances required for air circulation, servicing, and winter operation.\u003c\/p\u003e\n\u003ch3\u003eHeating down to -20 °C: information that must be interpreted correctly\u003c\/h3\u003e\n\u003cp\u003eYORK indicates a heating operating range of \u003cstrong\u003e-4 °F to 75 °F\u003c\/strong\u003e, or approximately \u003cstrong\u003e-20 °C to 24 °C\u003c\/strong\u003e, for the DHX09CSB11S. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis means that the unit is designed to be able to operate down to this minimum outdoor temperature.\u003c\/p\u003e\n\u003cp\u003eHowever, the \u003cstrong\u003eminimum operating temperature\u003c\/strong\u003e should not be confused with \u003cstrong\u003efull capacity guaranteed at -20 °C\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe documentation provided lists the nominal capacities and modulation ranges, but it does not publish a complete capacity curve at every outdoor temperature for the 115 V model in this table.\u003c\/p\u003e\n\u003cp\u003eThe AirGreen specifications also indicate values of \u003cstrong\u003e8,400 BTU at -8 °C\u003c\/strong\u003e and \u003cstrong\u003e8,700 BTU at -15 °C\u003c\/strong\u003e for this combination. For a homeowner planning to use the unit primarily as a heating source during the Quebec winter, we nevertheless recommend analyzing the building’s heating load and comparing the model with newer cold-climate heat pumps when very-low-temperature heating is the absolute priority.\u003c\/p\u003e\n\u003ch3\u003e23 SEER, but be careful not to confuse it with 23 SEER2\u003c\/h3\u003e\n\u003cp\u003eThe YORK brochure dates from 2020 and uses the older \u003cstrong\u003eSEER, EER, and HSPF\u003c\/strong\u003e metrics.\u003c\/p\u003e\n\u003cp\u003eFor this model, the published values are:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e23 SEER, 13 EER, and 10.5 HSPF.\u003c\/strong\u003e \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIt is important not to automatically present this rating as \u003cstrong\u003e23 SEER2\u003c\/strong\u003e. The SEER2 testing procedures introduced later are not identical to those used for the older SEER ratings.\u003c\/p\u003e\n\u003cp\u003eFor this reason, when comparing it with a modern heat pump advertised at 20 or 22 SEER2, data established using the same methods must be compared before concluding that one unit is more efficient than another.\u003c\/p\u003e\n\u003cp\u003eThis technical distinction helps avoid a common error in HVAC product comparisons.\u003c\/p\u003e\n\u003ch2\u003eWhat we look at at AirGreen before installing this YORK X Series system in Montréal, Laval, Longueuil, the North Shore, or the South Shore\u003c\/h2\u003e\n\u003ch3\u003e1\/4 in. – 3\/8 in. piping is a critical point when replacing a system\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDHX09CSB11S\u003c\/strong\u003e uses a \u003cstrong\u003e1\/4 in.\u003c\/strong\u003e liquid connection and a \u003cstrong\u003e3\/8 in.\u003c\/strong\u003e gas connection. The published maximum length is \u003cstrong\u003e49.2 ft\u003c\/strong\u003e, with a maximum elevation difference of \u003cstrong\u003e33 ft\u003c\/strong\u003e. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWhen replacing an old heat pump, we never assume that the existing lines can automatically be reused.\u003c\/p\u003e\n\u003cp\u003eWe verify:\u003c\/p\u003e\n\u003ch4\u003eThe actual line diameter\u003c\/h4\u003e\n\u003cp\u003eA refrigerant line whose diameter does not meet the manufacturer's requirements can compromise system operation.\u003c\/p\u003e\n\u003ch4\u003eThe condition of the copper\u003c\/h4\u003e\n\u003cp\u003eA crushed, contaminated, poorly insulated line or one with questionable connections must be corrected.\u003c\/p\u003e\n\u003ch4\u003eThe total length\u003c\/h4\u003e\n\u003cp\u003eWhen the outdoor unit is located at the other end of the building, the \u003cstrong\u003e49.2-foot maximum\u003c\/strong\u003e becomes a real design constraint.\u003c\/p\u003e\n\u003ch4\u003eThe drain path\u003c\/h4\u003e\n\u003cp\u003eThe condensate must be properly drained. An inadequate slope can cause water to accumulate or require a condensate pump.\u003c\/p\u003e\n\u003ch3\u003eWi-Fi is available, but it is not included as standard\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDRCPX\u003c\/strong\u003e remote control is included with the X Series. YORK also offers control through the \u003cstrong\u003eEWPE Smart\u003c\/strong\u003e app, but P and X models require the \u003cstrong\u003eCS532AH\u003c\/strong\u003e adapter to enable Wi-Fi connectivity. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis distinction should be clearly explained at the time of purchase.\u003c\/p\u003e\n\u003cp\u003eA customer who plans to use only the remote control does not necessarily need this option. However, Wi-Fi can be useful for a cottage, rental property, office, or simply for adjusting the temperature remotely.\u003c\/p\u003e\n\u003ch3\u003eSmart defrosting and outdoor construction suited to regular use\u003c\/h3\u003e\n\u003cp\u003eFor the X Series, YORK highlights a \u003cstrong\u003eheavy-gauge steel chassis\u003c\/strong\u003e, a \u003cstrong\u003ecorrosion-resistant coating\u003c\/strong\u003e, quiet operation, and demand-based defrosting rather than a rigid cycle. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIn winter, defrosting is essential for a heat pump. When the outdoor heat exchanger accumulates frost, the system must periodically remove it to maintain efficient heat exchange.\u003c\/p\u003e\n\u003cp\u003eDefrosting triggered when necessary is intended to limit unnecessary cycles, helping reduce the energy losses associated with this operation.\u003c\/p\u003e\n\u003ch3\u003eWarranty: verify registration rather than relying solely on the number of years displayed\u003c\/h3\u003e\n\u003cp\u003eThe AirGreen listing indicates a \u003cstrong\u003e10-year compressor, 10-year parts, 0-year labor\u003c\/strong\u003e warranty for this system, with the possibility of an additional warranty.\u003c\/p\u003e\n\u003cp\u003eThe YORK brochure for this generation nevertheless states that the published standard warranty was \u003cstrong\u003e7 years on the compressor and 5 years on parts\u003c\/strong\u003e, while residential registration of the system allowed an extension to \u003cstrong\u003e10 years on the compressor and 10 years on parts\u003c\/strong\u003e. A separate labor warranty program was also presented. \u003cspan class=\"contents\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eWhen installing or purchasing equipment from older inventory, we therefore recommend confirming eligibility, the installation date, registration, and the warranty terms applicable to the specific serial number.\u003c\/p\u003e\n\u003ch3\u003eA Scenario Where This Model Makes Perfect Sense\u003c\/h3\u003e\n\u003cp\u003eA typical example would be a small independent zone in a property without ductwork: a primary bedroom located far from the central system, a finished office, a small apartment, a home extension, or a space where an old window air conditioner needs to be replaced.\u003c\/p\u003e\n\u003cp\u003eFor this type of project, 9,000 BTU can make much more sense than an 18,000 BTU unit chosen “for safety.”\u003c\/p\u003e\n\u003cp\u003eThe right approach is to calculate the actual need and take advantage of the system’s modulation capacity.\u003c\/p\u003e\n\u003cp\u003eWe prefer to install \u003cstrong\u003ethe right capacity in the right location\u003c\/strong\u003e rather than compensate for poor air distribution with more BTUs.\u003c\/p\u003e\n\u003ch3\u003eWho Do We Primarily Recommend the YORK X Series 9000 BTU 115V to?\u003c\/h3\u003e\n\u003cp\u003eThis system is particularly suitable for:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ea small, well-defined residential zone;\u003c\/li\u003e\n\u003cli\u003ea bedroom or office where noise level is important;\u003c\/li\u003e\n\u003cli\u003ea property where a \u003cstrong\u003e115 V\u003c\/strong\u003e power supply is an advantage;\u003c\/li\u003e\n\u003cli\u003ea building without ductwork;\u003c\/li\u003e\n\u003cli\u003ea renovation where minimizing work is a priority;\u003c\/li\u003e\n\u003cli\u003ean installation where the refrigerant line run remains within the manufacturer’s limit;\u003c\/li\u003e\n\u003cli\u003ea homeowner seeking an inverter heat pump offering high seasonal efficiency for its generation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt is less suitable when several closed bedrooms must be heated from a single unit, when the actual thermal load exceeds 9,000 BTU, or when the project primarily requires cold-climate performance and the certifications of current-generation heat pumps.\u003c\/p\u003e\n\u003ch3\u003eWhy Entrust Sizing and Installation to AirGreen\u003c\/h3\u003e\n\u003cp\u003eA proper \u003cstrong\u003ewall-mounted heat pump installation in Montreal, Laval, Longueuil, the North Shore, or the South Shore\u003c\/strong\u003e involves more than mounting two units and connecting two pipes.\u003c\/p\u003e\n\u003cp\u003eAt \u003cstrong\u003eAirGreen\u003c\/strong\u003e, we analyze the project as a whole: capacity, electrical supply, indoor location, outdoor clearances, noise, drainage, piping, future maintenance accessibility, and the system’s expected performance in both heating and cooling modes.\u003c\/p\u003e\n\u003cp\u003eFor a compact unit such as the \u003cstrong\u003eYORK X Series 23 SEER 9000 BTU 115V\u003c\/strong\u003e, this preparation allows you to truly benefit from its advantages: low minimum capacity, quiet indoor operation, compact design, and 115 V power supply.\u003c\/p\u003e\n\u003ch3\u003eRequest Your AirGreen Quote\u003c\/h3\u003e\n\u003cp\u003eTo determine whether the \u003cstrong\u003eYORK X Series 23 SEER Mini Split | 9000 BTU 115V\u003c\/strong\u003e, models \u003cstrong\u003eDHX09NWB11S \/ DHX09CSB11S\u003c\/strong\u003e, is suitable for your property, contact \u003cstrong\u003eAirGreen Heat Pumps, Air Conditioning \u0026amp; Heating\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eWe can assess your space, check the electrical requirements, and compare this YORK with other wall-mounted solutions suited to your project in \u003cstrong\u003eMontreal, Laval, Longueuil, the North Shore, the South Shore, and Montérégie\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhone: 514-316-2973\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eEmail: \u003ca class=\"decorated-link cursor-pointer\" rel=\"noopener\"\u003esales@airgreen.ca\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"York","offers":[{"title":"Default Title","offer_id":56120414306596,"sku":"DHX09CSB11S","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/00_MINI_SPLIT_YORK_SERIE_X_9000_BTU_115V_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD_44db7dba-bd8f-4f87-ad4e-a5d418e8ac72.png?v=1789425740","url":"https:\/\/airgreen.ca\/en\/products\/mini-split-york-serie-x-23-seer-9000-btu-115v","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}