{"product_id":"serpentin-devaporateur-adp-he30c24a155a0004r-a-2-tonnes","title":"ADP HE30C24A155A0004R Evaporator A-Coil | 2 Tons","description":"\u003ch2\u003eHE30C24A155A0004R: 15-1\/2 in wide, 11 in low, a two-ton ADP coil\u003c\/h2\u003e\n\u003cp\u003eSome furnaces are wide and yet squeezed under a low ceiling. If that is your case, a standard coil is hard to fit. The \u003cstrong\u003eHE30C24A155A0004R\u003c\/strong\u003e combines two features that the other models in the series do not add together: 15-1\/2 in of width and 11 in of height, with 19-1\/2 in of depth. Nominal capacity: two tons, 24,000 BTU\/h, with \u003cstrong\u003eR-454B\u003c\/strong\u003e refrigerant.\u003c\/p\u003e\n\n\u003ch3\u003eAn identity card in a few lines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emanufacturer: ADP, HE line, uncased evaporator coil;\u003c\/li\u003e\n\u003cli\u003edimensions W × H × D: 15-1\/2 × 11 × 19-1\/2 in;\u003c\/li\u003e\n\u003cli\u003enet weight: 22 lb;\u003c\/li\u003e\n\u003cli\u003enominal airflow: 800 CFM;\u003c\/li\u003e\n\u003cli\u003eexpansion valve: HP-A\/C bleed TXV for R-454B;\u003c\/li\u003e\n\u003cli\u003esuction connection: 3\/4 in ODF;\u003c\/li\u003e\n\u003cli\u003edrain: two 3\/4 in FPT outlets, front left and front right.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThree scenarios where it fits just right\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFirst case:\u003c\/strong\u003e a plex in \u003cstrong\u003eMontreal\u003c\/strong\u003e whose basement was partitioned after the fact, with a wide furnace and tight clearance above. \u003cstrong\u003eSecond case:\u003c\/strong\u003e a bungalow in \u003cstrong\u003eLaval\u003c\/strong\u003e where an electric furnace at the end of its life must become a central heat pump without touching the joists. \u003cstrong\u003eThird case:\u003c\/strong\u003e a home in \u003cstrong\u003eLongueuil\u003c\/strong\u003e or on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e where the old, taller coil forced someone to rig up a makeshift cabinet.\u003c\/p\u003e\n\u003cp\u003eIn each of these cases, the same question comes up: what is the width of the opening, and how much height is left? If both answers match this size, the decision is made quickly.\u003c\/p\u003e\n\n\u003ch3\u003eIf the furnace is not quite this size\u003c\/h3\u003e\n\u003cp\u003eA gap is not an obstacle. We build an insulated transition on site that connects the coil to the existing opening. It is a common step in renovation. It takes insulation, sealed joints and a bit of time, but it avoids redoing the whole plenum.\u003c\/p\u003e\n\u003cp\u003eOur visit serves to decide between the model as is and the model with a transition. We also check that the blower can deliver the nominal airflow.\u003c\/p\u003e\n\n\u003ch3\u003eHow it works, from refrigerant to drain\u003c\/h3\u003e\n\u003cp\u003eThe cooled liquid arrives from the outdoor unit, passes through the expansion valve and evaporates in the tubes. The air passing through gives up its heat, and the condensed water runs to one or the other of the drain outlets. In winter, with a heat pump, the exchange is reversed: the air of the house is warmed on contact with the coil. The furnace serves as backup when the outdoor temperature drops below the threshold chosen together.\u003c\/p\u003e\n\u003cp\u003eADP rates this coil as multi-position: upflow, horizontal left or right, or downflow according to the manufacturer's downflow airflow table.\u003c\/p\u003e\n\n\u003ch3\u003eThe sensor that watches over the R-454B\u003c\/h3\u003e\n\u003cp\u003eA refrigerant detection system is mounted at the factory, with a controller and a sensor (code R). As soon as it senses a leak, it cuts the 24 V thermostat power: the compressor and heating stop, and the fan runs to disperse the refrigerant. It keeps going for 7 more min once the reading has returned below the threshold.\u003c\/p\u003e\n\n\u003ch3\u003eSelection chart for the series\u003c\/h3\u003e\n\u003cp\u003eHere is how this model stands against the other four:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eHE21C18A140A0004R\u003c\/strong\u003e: 1.5 tons and 14 in wide, for small loads;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHE21C24A140A0004R\u003c\/strong\u003e: two tons, 14 in wide, taller body;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHE21C24A155A0004R\u003c\/strong\u003e: two tons, 15-1\/2 in wide, taller body;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHE30C24A140A0004R\u003c\/strong\u003e: two tons, low profile, but only 14 in wide;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHE30C24A155A0004R\u003c\/strong\u003e: two tons, low profile and 15-1\/2 in wide; this is the one.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eChoose the latter when both constraints are present at once. If only width matters, a taller model is enough; if only height matters, the 14 in model is suitable.\u003c\/p\u003e\n\n\u003ch3\u003eThe required pairing with the outdoor unit\u003c\/h3\u003e\n\u003cp\u003eThis coil has no efficiency rating of its own. The published ratings belong to the certified system, that is, the coil and an ADP outdoor unit of the same capacity and the same refrigerant. Before ordering, we find the AHRI number of the pairing and confirm it. That number is what lets you compare two quotes fairly.\u003c\/p\u003e\n\n\u003ch3\u003eWhat changes in the home\u003c\/h3\u003e\n\u003cp\u003eIn mild weather, a heat pump produces two to three times more heat than the electricity it takes in. The gain shrinks in a hard freeze, and the furnace then takes over. In summer, you enjoy cool, drier air in every room, thanks to the ducts already in place.\u003c\/p\u003e\n\n\u003ch3\u003eThe AirGreen installation\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. We also serve the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e. The work includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003erecording the dimensions, the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003efitting the coil and sealing the joints;\u003c\/li\u003e\n\u003cli\u003ethe outdoor unit, brazed piping, the nitrogen test and evacuation;\u003c\/li\u003e\n\u003cli\u003ethe drain, the thermostat, commissioning and the demonstration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eManufacturer's warranty: 5 years from installation, up to 6 years after manufacture, with a 10-year limited warranty on registration.\u003c\/p\u003e\n\n\u003ch3\u003eBefore you decide\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003efurnace width: 15-1\/2 in;\u003c\/li\u003e\n\u003cli\u003eclear height: 11 in;\u003c\/li\u003e\n\u003cli\u003eR-454B refrigerant indoors and outdoors;\u003c\/li\u003e\n\u003cli\u003ea blower capable of the required airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy the wide-and-low combination is less common\u003c\/h3\u003e\n\u003cp\u003eMost coils come in either a width or a height, rarely both at once. In this series, the models split into two widths and two heights: this one is the only one to marry 15-1\/2 in and 11 in. For the installer, it avoids having to choose between a wide transition and raising the plenum.\u003c\/p\u003e\n\u003cp\u003eThis size weighs 22 lb net, like its 14 in neighbour of the same height. It is heavier than the taller models, but it is still easy for two people to carry.\u003c\/p\u003e\n\n\u003ch3\u003eWhen another model is the better choice\u003c\/h3\u003e\n\u003cp\u003eLet us be frank: this coil is not always the right one. If your plenum offers height, a taller model will do just as well and will sometimes be simpler to install. If your furnace is narrow, the 14 in version avoids a transition. And if the home is small, the 1.5-ton model in the series may control summer humidity better. Our role is to say so before the order, not after.\u003c\/p\u003e\n\n\u003ch3\u003eAfter installation: a few simple steps\u003c\/h3\u003e\n\u003cp\u003eChange the filter regularly, keep the drain outlets clear and schedule an annual check of the system. After commissioning, we give you a written summary of the settings, including the winter switchover threshold to the furnace, which we can adjust with you over the seasons.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we explain on site\u003c\/h3\u003e\n\u003cp\u003eOn commissioning day, we go over the thermostat with you, the location of the filter, the expected behaviour of the leak sensor and how to shut the system down if in doubt. We also answer questions about normal noises, about the drain water and about the first weeks of use. A successful installation also means a homeowner who is comfortable with the equipment.\u003c\/p\u003e\n\n\u003ch3\u003eHydro-Québec incentives\u003c\/h3\u003e\n\u003cp\u003eEligibility depends on the complete system and not on the coil alone. We check the official list at the time of the quote, according to the installation date.\u003c\/p\u003e\n\n\u003ch3\u003eGet your quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete ADP system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e","brand":"ADP","offers":[{"title":"Default Title","offer_id":68402415599908,"sku":"HE30C24A155A0004R","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HE_HE30C24A155A0004R_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765599","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-adp-he30c24a155a0004r-a-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}