{"product_id":"serpentin-devaporateur-adp-he32c36a155a0004r-a-3-tonnes","title":"ADP HE32C36A155A0004R Evaporator A-Coil | 3 Tons","description":"\u003ch2\u003eA home visit with the HE32C36A155A0004R: ADP 3-ton coil, 15-1\/2 in wide, 15 in high\u003c\/h2\u003e\n\u003cp\u003eThe best way to understand an evaporator coil is to follow what happens on the day we come to measure it at your home. The HE32C36A155A0004R is an ADP uncased A-coil rated at 3 tons (36,000 BTU\/h), using R-454B refrigerant. Here is how a typical visit goes, followed by the reasons this model turns up often in our quotes.\u003c\/p\u003e\n\n\u003ch3\u003eArrival: we look at the furnace first\u003c\/h3\u003e\n\u003cp\u003eThe technician starts in the basement. He locates the furnace or blower cabinet, removes the plenum access panel and notes the width of the opening. If it is close to 15-1\/2 in, the HE32C36A155A0004R goes on the list of candidates. That figure is the same as for several other models in the series, which is why width alone does not decide.\u003c\/p\u003e\n\u003cp\u003eThe technician then measures the vertical space. This model is 15 in high and 19-1\/2 in deep, and weighs 28 lb. It goes in without a crane or scaffolding, but there must be room to handle it, to connect it and to bring out the 3\/4 in ODF suction line.\u003c\/p\u003e\n\n\u003ch3\u003eSecond stop: the electrical panel and the outdoor unit location\u003c\/h3\u003e\n\u003cp\u003eThe outdoor unit goes on the ground or on a bracket, away from ice falling off the roof. We check the distance to the coil, the route of the piping and the capacity of the electrical panel. This step is not about the coil itself, but it shapes the quote, because the system works as a pair.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the coil does once installed\u003c\/h3\u003e\n\u003cp\u003eThe coil sits in the path of the air, between the furnace blower and the ducts. In summer, it cools and dries the air. The condensate falls into the pan and flows out through one of the two 3\/4 in FPT drain connections, front left or front right. In winter, with a heat pump, it distributes the heat captured outdoors.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModel: HE32C36A155A0004R, ADP HE line.\u003c\/li\u003e\n\u003cli\u003eType: A-shaped evaporator coil, uncased.\u003c\/li\u003e\n\u003cli\u003eSize: 3 tons (36,000 BTU\/h).\u003c\/li\u003e\n\u003cli\u003eDimensions W × H × D: 15-1\/2 × 15 × 19-1\/2 in; net weight: 28 lb.\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B; HP-A\/C bleed TXV expansion valve.\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 1,200 CFM.\u003c\/li\u003e\n\u003cli\u003ePositions: upflow, horizontal left or right, downflow per ADP's downflow airflow chart.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHow this model compares with its siblings\u003c\/h3\u003e\n\u003cp\u003eWhen deciding, we always ask three questions: what width, what height, what weight? This model answers \"15-1\/2 in\" to the first.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIf the furnace is narrow, we look at the HE32C36A140A0004R or the HE33C36A140A0004R, at 14 in.\u003c\/li\u003e\n\u003cli\u003eIf it is wide, the HE32C36A170A0004R, like the HE23C36A170A0004R, HE33C36A170A0004R and HE35C36A170A0004R, is 17 in.\u003c\/li\u003e\n\u003cli\u003eFor the same 15-1\/2 in width, there are the HE23C36A155A0004R, HE33C36A155A0004R, HE35C36A155A0004R and HE36C36A155A0004R. Their height or weight differs from that of the HE32C36A155A0004R; the space available above your furnace settles it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eKeep in mind that the size, the refrigerant and the expansion valve are identical across the series. The choice comes down to the footprint.\u003c\/p\u003e\n\n\u003ch3\u003eThe match, piece by piece\u003c\/h3\u003e\n\u003cp\u003eA coil is not sold without an outdoor unit. This one is paired with an ADP unit of the same capacity and the same refrigerant. The SEER2, EER2 and HSPF2 ratings shown on the data sheets belong to the pair, not to the coil. An AHRI number links the two elements. We confirm it before the order, so that a quote never advertises an efficiency that would not match the combination actually installed.\u003c\/p\u003e\n\n\u003ch3\u003eOn the day of the work\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFinal check of the measurements, the blower and the electrical panel.\u003c\/li\u003e\n\u003cli\u003eSetting the coil in the plenum, with an insulated transition built on site if there is a width gap, and sealed duct connections.\u003c\/li\u003e\n\u003cli\u003ePlacing the outdoor unit, brazed piping, nitrogen leak test, evacuation.\u003c\/li\u003e\n\u003cli\u003eConnecting the drain and the thermostat.\u003c\/li\u003e\n\u003cli\u003eStart-up, airflow adjustment and a demonstration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOur crews are based in Montreal and travel to Laval, Longueuil, the North Shore and the South Shore. The work is done under our RBQ licence 5645-9605-01.\u003c\/p\u003e\n\n\u003ch3\u003eBuilt-in leak detection\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer has factory-mounted a refrigerant controller and sensor (code R). When the sensor detects a leak, the thermostat loses its 24 V power; the compressor and the heating stop, the fan starts to stir the air, and it keeps running for 7 min after the level returns below the threshold. It is automatic, not a setting.\u003c\/p\u003e\n\n\u003ch3\u003eThe furnace keeps a role\u003c\/h3\u003e\n\u003cp\u003eIn an \"add-on\" installation, the furnace keeps its blower, its filters and its heating elements. When the outdoor temperature falls below the agreed threshold, it takes over. This split avoids oversizing the heat pump for the few very cold days of the year.\u003c\/p\u003e\n\n\u003ch3\u003eWarranty\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer covers the unit for 5 years from installation, with a maximum of 6 years after manufacture. A 10-year limited warranty is available with registration.\u003c\/p\u003e\n\n\u003ch3\u003eThree questions we get during the visit\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan it also heat?\u003c\/strong\u003e Yes, if the outdoor unit is a heat pump: the house is cooled in summer and heated in winter. With a simple central air conditioner, it only cools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan my old air conditioner stay?\u003c\/strong\u003e Generally not. The coil runs on R-454B and requires the outdoor unit specified by the manufacturer. We install the complete system so that everything is compatible.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat if my furnace is not the same width?\u003c\/strong\u003e We measure and, if needed, build an insulated transition on site. It is a routine operation for us and it does not compromise the durability of the assembly.\u003c\/p\u003e\n\n\u003ch3\u003eWhat it changes in daily life\u003c\/h3\u003e\n\u003cp\u003eAfter installation, the difference shows mostly in July. The air circulates through the same registers as the heating, the house dries out and the noise of window air conditioners disappears. In winter, the heat pump provides most of the heat, and the furnace simply takes over at the lowest temperatures. You still have a single thermostat: you set the house, not two devices.\u003c\/p\u003e\n\u003cp\u003eThe bill follows the same logic. An electric furnace turns every kilowatt-hour into an equal amount of heat, whereas a heat pump moves heat and delivers two to three times more in mild temperatures. The colder it gets, the more that advantage shrinks, which is why the furnace stays as backup.\u003c\/p\u003e\n\n\u003ch3\u003eTo check before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil and the outdoor unit both run on R-454B.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified match.\u003c\/li\u003e\n\u003cli\u003eThe furnace must have the right width and blower; we confirm them on site.\u003c\/li\u003e\n\u003cli\u003eThe space above the furnace must accept the height of the coil.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFinancial help\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec incentives, such as LogisVert, depend on the complete system. We check the official list at the time of the quote, based on the installation date, then explain what applies to your file.\u003c\/p\u003e\n\n\u003ch3\u003eEnd of the visit: estimate and financing\u003c\/h3\u003e\n\u003cp\u003eAt the end of the visit, you receive a written quote for the complete ADP system. The estimate is free. If you would like to spread the expense, \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is available. For the next step, just tell us the date that suits you.\u003c\/p\u003e\n","brand":"ADP","offers":[{"title":"Default Title","offer_id":68402427003172,"sku":"HE32C36A155A0004R","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HE_HE32C36A155A0004R_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765591","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-adp-he32c36a155a0004r-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}