{"product_id":"serpentin-devaporateur-adp-he35c48a200a0004r-a-4-tonnes","title":"ADP HE35C48A200A0004R Evaporator A-Coil | 4 Tons","description":"\u003ch2\u003eADP HE35C48A200A0004R coil: 4 tons and 20 in wide for furnaces with some width to them\u003c\/h2\u003e\n\u003cp\u003eSome furnaces have a wide plenum, often those in large two-storey homes or in bungalows with a finished basement. For them, a coil that is too narrow forces improvised connections. The \u003cstrong\u003eHE35C48A200A0004R\u003c\/strong\u003e was designed differently: its 20 in width matches these plenums, and its 4-ton capacity (48,000 BTU\/h) follows the airflow that these homes call for.\u003c\/p\u003e\n\u003cp\u003eHere, in question form, is what homeowners in Montreal, Laval, Longueuil, the North Shore and the South Shore ask us most often about it.\u003c\/p\u003e\n\n\u003ch3\u003eMy furnace is wide: is this coil right for it?\u003c\/h3\u003e\n\u003cp\u003eThat is exactly its niche. At 20 in, it comes close to the width of more generous furnaces and limits the need for a transition. If yours is a little narrower, we build an insulated connecting piece on site; a difference in size is never a reason to give up.\u003c\/p\u003e\n\u003cp\u003eIts dimensions W × H × D are 20 × 21 × 19-1\/2 in. It weighs 39 lb net, which is still reasonable to handle on a basement staircase.\u003c\/p\u003e\n\n\u003ch3\u003eWhat does \"uncased\" mean?\u003c\/h3\u003e\n\u003cp\u003eThe coil arrives bare, without the metal shell that usually surrounds it. It sits in the furnace plenum, or in a cabinet that we build as needed. For you, this means the existing shell is reused when it is in good shape, instead of paying for one more enclosure.\u003c\/p\u003e\n\n\u003ch3\u003eCan it be used for heating?\u003c\/h3\u003e\n\u003cp\u003eYes, provided it is paired with a heat pump. In summer, it cools and dries the air; in winter, the cycle reverses and the heat captured outdoors is delivered through the same vents. With a simple central air conditioner, it only provides cooling. The furnace keeps its backup role for the coldest days, according to the temperature threshold that we program together.\u003c\/p\u003e\n\n\u003ch3\u003eCan I keep my current air conditioner?\u003c\/h3\u003e\n\u003cp\u003eGenerally not. This coil runs on R-454B refrigerant and must be connected to the outdoor unit specified by the manufacturer, of the same capacity. We therefore install both parts together; this is what makes a certified match possible, with an AHRI number that we confirm before the order.\u003c\/p\u003e\n\n\u003ch3\u003eThe features of the HE35C48A200A0004R, point by point\u003c\/h3\u003e\n\u003cp\u003eHere is what the manufacturer publishes for this model in the HE line.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCapacity:\u003c\/strong\u003e 4 tons, 48,000 BTU\/h nominal.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eRefrigerant:\u003c\/strong\u003e R-454B.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eExpansion device:\u003c\/strong\u003e HP-A\/C bleed TXV, set for R-454B.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eNominal airflow:\u003c\/strong\u003e 1,600 CFM.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eSuction line:\u003c\/strong\u003e 7\/8 in ODF.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCondensate drainage:\u003c\/strong\u003e two 3\/4 in FPT outlets, one at the front left and the other at the front right; we choose the more practical side for your basement.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003ePositions:\u003c\/strong\u003e multi-position (upflow, horizontal left or right), with an ADP downflow airflow table for the downflow configuration.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eWarranty:\u003c\/strong\u003e 5 years from installation, to a maximum of 6 years after manufacture; a 10-year limited warranty is available on registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe refrigerant detection system, explained simply\u003c\/h3\u003e\n\u003cp\u003eThe letter R at the end of the model number indicates that the controller and the leak sensor are factory-mounted. If the sensor detects refrigerant, it cuts the 24 V power from the thermostat. The compressor and the heating then stop working, while the fan starts running. Once the level is acceptable again, the fan keeps running for another 7 min before stopping. You have nothing to program: it is a safety net that is part of the unit.\u003c\/p\u003e\n\n\u003ch3\u003eThe 20 in HE35: does it stand out from its three neighbours?\u003c\/h3\u003e\n\u003cp\u003eFour 4-ton coils make up this series, all using R-454B, all uncased, all with the same bleed TXV expansion device. Only two criteria separate them: the width and the size of the line code.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe \u003cstrong\u003eHE35C48A170A0004R\u003c\/strong\u003e is 17 in wide, a choice for furnaces of common size.\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eHE35C48A200A0004R\u003c\/strong\u003e, the one on this page, is 20 in wide and aimed at wider plenums.\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eHE36C48A170A0004R\u003c\/strong\u003e is 17 in wide, with a taller and slightly heavier body than the HE35.\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eHE36C48A200A0004R\u003c\/strong\u003e combines a 20 in width with that taller body.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA simple rule: start from the width of the furnace, then check the height available in the plenum. If you have some vertical space, an HE36 model remains possible; if clearance is tight, the 20 in HE35 keeps the advantage.\u003c\/p\u003e\n\n\u003ch3\u003eWhat our job includes for a coil of this size\u003c\/h3\u003e\n\u003cp\u003eA 4-ton coil moves a lot of air, which is why the blower and the connections deserve as much attention as the coil itself. Our work list includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and a look at the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, with an insulated transition if the width requires it, and sealing the air joints;\u003c\/li\u003e\n\u003cli\u003esetting the outdoor unit on a pad or bracket, brazed piping, the nitrogen leak test and then the vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003estart-up, airflow adjustment and a demonstration at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWhy a heat pump changes the bill for a large home\u003c\/h3\u003e\n\u003cp\u003eIn a large home, baseboard or electric furnace heat weighs heavily on the winter bill, because every kilowatt-hour becomes exactly one kilowatt-hour of heat. A heat pump, on the other hand, carries heat from outside to inside; in mild weather, it delivers more heat than the electricity it uses. The colder it gets, the weaker that ratio becomes, and the furnace then goes back to work. The result: a large part of the season is covered by the heat pump, and the backup steps in only for the harshest days.\u003c\/p\u003e\n\u003cp\u003eIn summer, the same coil replaces several window air conditioners with a single outdoor unit. The upstairs bedrooms and the basement receive the same cool air through the existing vents.\u003c\/p\u003e\n\u003ch3\u003eWhat a coil does not tell you about efficiency\u003c\/h3\u003e\n\u003cp\u003eThis coil has no efficiency rating of its own. The ratings shown in a quote describe the matched system, never an isolated part. That is why we always require the AHRI number of the match: it allows an honest comparison of two offers and also serves as a reference when applying for an incentive.\u003c\/p\u003e\n\n\u003ch3\u003eBefore signing, check these four things\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDoes the 20 in width fit the furnace, or should a transition be planned?\u003c\/li\u003e\n\u003cli\u003eIs the blower able to deliver the system's airflow?\u003c\/li\u003e\n\u003cli\u003eDoes the proposed outdoor unit really use R-454B?\u003c\/li\u003e\n\u003cli\u003eDoes the quote show the AHRI number of the complete system?\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFinancial assistance\u003c\/h3\u003e\n\u003cp\u003eIncentives depend on the complete system. We consult the official Hydro-Québec list according to the installation date and tell you what is eligible in your case, without promising an amount that we cannot confirm.\u003c\/p\u003e\n\n\u003ch3\u003eBook an appointment for an estimate\u003c\/h3\u003e\n\u003cp\u003eWe travel to measure the furnace, check the electrical service and give you a written quote for the complete ADP system. To spread out the expense, see our \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e page.\u003c\/p\u003e\n\n\u003ch2\u003eA local team, one visit to sort everything out\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is covered by our RBQ licence 5645-9605-01. From measuring to the final adjustment, our technicians take care of the HE35C48A200A0004R and its outdoor unit, anywhere in Greater Montreal.\u003c\/p\u003e\n","brand":"ADP","offers":[{"title":"Default Title","offer_id":68402454036772,"sku":"HE35C48A200A0004R","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HE_HE35C48A200A0004R_00_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765597","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-adp-he35c48a200a0004r-a-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}