{"product_id":"serpentin-devaporateur-adp-he36c48a200a0004r-a-4-tonnes","title":"ADP HE36C48A200A0004R Evaporator A-Coil | 4 Tons","description":"\u003ch2\u003eHE36C48A200A0004R, the largest size in the series: 20 in wide, 23 in tall, 4 tons\u003c\/h2\u003e\n\u003cp\u003eAmong the four uncased 4-ton coils in this ADP series, the \u003cstrong\u003eHE36C48A200A0004R\u003c\/strong\u003e combines the greatest width (20 in) and the tallest body (23 in). It weighs 41 lb net. Using R-454B, it sits on a furnace or a blower cabinet and pairs with an ADP outdoor unit of the same capacity, that is 4 tons or 48,000 BTU\/h nominal.\u003c\/p\u003e\n\u003cp\u003eRather than rolling out a spec sheet right away, let's follow this coil through a year in a home in Montreal, Laval, Longueuil, the North Shore or the South Shore. You understand what a coil is for better when you watch it work through the seasons.\u003c\/p\u003e\n\n\u003ch3\u003eSpring: the visit and the match\u003c\/h3\u003e\n\u003cp\u003eThe mild shoulder season is ideal for planning, because neither heating nor cooling is pressing. A technician measures the furnace, examines the plenum and checks whether the blower can deliver the system's airflow. For a coil of this size, we look in particular at the vertical and lateral space, because it is both wide and tall.\u003c\/p\u003e\n\u003cp\u003eWe also look up the exact match with the outdoor unit in the AHRI directory. The number obtained becomes the reference for the quote.\u003c\/p\u003e\n\n\u003ch3\u003eSummer: cool air in every room\u003c\/h3\u003e\n\u003cp\u003eDuring heat waves, the refrigerant evaporates in the tubes of the coil and absorbs heat from the air passing through. The moisture condenses, drops into the pan and runs to the drain, since the HE36C48A200A0004R has two 3\/4 in FPT connections, at the front left and the front right. The result: the air distributed is cooler and less muggy, in the bedrooms as in the basement.\u003c\/p\u003e\n\n\u003ch3\u003eFall: fine-tuning before the first cold\u003c\/h3\u003e\n\u003cp\u003eThis is the time to program the switchover point between the heat pump and the furnace. We set it with you according to the insulation of the house and your tolerance for cold. Nothing prevents changing it later.\u003c\/p\u003e\n\n\u003ch3\u003eWinter: the heat pump takes over\u003c\/h3\u003e\n\u003cp\u003eThe cycle reverses. The refrigerant warmed by the outdoor unit gives up its heat to the air passing through the coil, and your existing vents blow warm air. During periods of intense cold, the furnace becomes the backup again: it keeps its blower, its filters and its heating elements, and goes to work below the agreed threshold.\u003c\/p\u003e\n\u003cp\u003eThis coil alone has no efficiency rating. The published ratings describe the matched system and its AHRI number.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we check before choosing this size\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe furnace is wide enough to take 20 in without a transition, or we build one, insulated, on site.\u003c\/li\u003e\n\u003cli\u003eThe 23 in height fits in the plenum or the blower cabinet.\u003c\/li\u003e\n\u003cli\u003eThe blower provides the required airflow; otherwise comfort suffers.\u003c\/li\u003e\n\u003cli\u003eThe outdoor unit uses R-454B like the coil.\u003c\/li\u003e\n\u003cli\u003eThe complete system appears on the official Hydro-Québec list on the installation date.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThe manufacturer's data in brief\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLine: HE, uncased evaporator coil;\u003c\/li\u003e\n\u003cli\u003eNominal size: 4 tons (48,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003eDimensions W × H × D: 20 × 23 × 19-1\/2 in;\u003c\/li\u003e\n\u003cli\u003eNet weight: 41 lb;\u003c\/li\u003e\n\u003cli\u003eExpansion device: HP-A\/C bleed TXV, R-454B;\u003c\/li\u003e\n\u003cli\u003eNominal airflow: 1,600 CFM;\u003c\/li\u003e\n\u003cli\u003eSuction: 7\/8 in ODF;\u003c\/li\u003e\n\u003cli\u003eWarranty: 5 years from installation, 6 years maximum after manufacture; 10 years limited on registration;\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAs for orientation, the coil is multi-position: it can be placed upflow or horizontal, left or right side. For a downflow installation, we refer to ADP's downflow airflow table.\u003c\/p\u003e\n\n\u003ch3\u003eBuilt-in leak detection\u003c\/h3\u003e\n\u003cp\u003eA controller and a sensor, factory-mounted, form the refrigerant detection system (RDS), identified by the R code. If it detects refrigerant, it cuts the 24 V power from the thermostat: the compressor and the heating stop, while the fan runs. After the level returns below the threshold, it runs for another 7 min.\u003c\/p\u003e\n\n\u003ch3\u003eThe HE36C48A200A0004R compared with the other three coils\u003c\/h3\u003e\n\u003cp\u003eHere is the comparison, straight up. The four models share the 4-ton capacity, R-454B refrigerant, the absence of a cabinet and the same type of expansion device.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eHE35C48A170A0004R\u003c\/strong\u003e: 17 in wide, shorter and lighter body. The most compact of the four.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHE35C48A200A0004R\u003c\/strong\u003e: 20 in wide, shorter body.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHE36C48A170A0004R\u003c\/strong\u003e: 17 in wide, tall body.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eHE36C48A200A0004R\u003c\/strong\u003e (this page): 20 in wide, tall body.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 20 in HE36 is therefore the one that needs the most space. If the furnace is wide and height is not a problem, it fits well. If vertical space is limited, the 20 in HE35 does the same job with a lower profile. If the furnace is narrow, a 17 in model, with or without a transition, will be a better fit.\u003c\/p\u003e\n\n\u003ch3\u003eCan the old air conditioner be kept?\u003c\/h3\u003e\n\u003cp\u003eIn principle, no. The coil runs on R-454B and pairs with the outdoor unit specified by the manufacturer, installed at the same time. We install the complete system, from the coil to the brazed piping, including the nitrogen test and the vacuum.\u003c\/p\u003e\n\n\u003ch3\u003eWhy keep the furnace when adding a heat pump\u003c\/h3\u003e\n\u003cp\u003eMany homeowners think everything has to be replaced. That is not the case. The furnace remains useful: it supplies the blower that pushes the air, the filters that clean it and the heating elements that take over in extreme cold. The coil is inserted in the plenum and completes the assembly, which limits the scope of the work and avoids touching the ducts.\u003c\/p\u003e\n\u003cp\u003eFor a large home, this approach keeps the distribution network as it is, with its vents and returns, while the source of heating and cooling is renewed.\u003c\/p\u003e\n\u003ch3\u003eFrequently asked questions about this model\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the coil heat on its own?\u003c\/strong\u003e No. It heats only when a heat pump sends it hot refrigerant; with a central air conditioner, it only cools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy furnace has a different width, what should I do?\u003c\/strong\u003e We measure it, then build an insulated transition on site if necessary.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo incentives apply to the coil?\u003c\/strong\u003e They apply to the complete system, never to the part alone.\u003c\/p\u003e\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eEligibility for Hydro-Québec programs depends on the matched system, not on the coil taken alone. We check the official list according to the installation date, then tell you what applies to your project.\u003c\/p\u003e\n\n\u003ch3\u003eA free estimate, then financing\u003c\/h3\u003e\n\u003cp\u003eWe come to your home to measure the furnace, check the electrical service and write a quote for the complete ADP system. If you wish to spread out the cost, see the \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e available.\u003c\/p\u003e\n\n\u003ch2\u003eAirGreen, from the spring visit to winter service\u003c\/h2\u003e\n\u003cp\u003eAirGreen is a family-run heating and cooling company based in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work. We install the HE36C48A200A0004R and its outdoor unit in Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n","brand":"ADP","offers":[{"title":"Default Title","offer_id":68402421924132,"sku":"HE36C48A200A0004R","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ADP_HE_HE36C48A200A0004R_00_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765601","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-adp-he36c48a200a0004r-a-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}