{"product_id":"serpentin-devaporateur-ameristar-4mxca003ac6hca-a-1-5-a-3-tonnes","title":"AMERISTAR 4MXCA003AC6HCA Evaporator A-Coil | 1.5 to 3 Tons","description":"\u003ch2\u003eThe 4MXCA003AC6HCA: a 1.5 to 3 ton Ameristar coil for the narrow furnace\u003c\/h2\u003e\n\n\u003ch3\u003eChanging seasons without changing ducts\u003c\/h3\u003e\n\n\u003cp\u003eHere is a simple way to explain this product: think about how your home lives through a full year. In January, the furnace blows. In July, you close the blinds and dream of a cooler upstairs. The \u003cstrong\u003eAmeristar 4MXCA003AC6HCA evaporator coil\u003c\/strong\u003e is the part that lets the same air ductwork serve in both cases. It is a cased A-coil from the 4MXC range, with a nominal size of 1.5 to 3 tons (36,000 BTU\/h), and it uses R-410A refrigerant.\u003c\/p\u003e\n\n\u003ch3\u003eSpring: the time to assess it\u003c\/h3\u003e\n\n\u003cp\u003eVisits are easy to schedule before the heat arrives. We come to your home in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, and we look at the furnace, the access to the plenum and the electrical panel. We note the width of the furnace: this model is 14-1\/2 in. If yours differs, an insulated transition is built on site.\u003c\/p\u003e\n\n\u003cp\u003eWhat matters at this stage is the conversation about your habits. A room that is hard to cool, a damp basement, an upper floor that stays lukewarm: all of this feeds the load calculation that tells us whether 1.5 to 3 tons is the right range.\u003c\/p\u003e\n\n\u003ch3\u003eSummer: cool air in every room\u003c\/h3\u003e\n\n\u003cp\u003eAs soon as the outdoor unit is running, refrigerant flows through the coil. The warm air from the house passes through it, gives up its heat and moisture, then heads back out to the ducts. The condensation falls into the pan and runs to the 3\/4 in NPT drain. A single system replaces the window units, and the house becomes drier, which makes a big difference to how muggy days feel.\u003c\/p\u003e\n\n\u003ch3\u003eWinter: the heat pump takes over\u003c\/h3\u003e\n\n\u003cp\u003eWith a central heat pump as the outdoor unit, the cycle reverses. The refrigerant picks up heat outside and gives it to the air passing through the coil. The furnace remains available: it keeps its blower and its filters and serves as backup on the harshest nights, according to the threshold we set with you.\u003c\/p\u003e\n\n\u003cp\u003eFor a homeowner who currently heats with electricity, this is where the value lies: the heat pump moves heat instead of making it, and in mild weather delivers two to three times more heat than the electricity it consumes.\u003c\/p\u003e\n\n\u003ch3\u003eThe shape of the coil\u003c\/h3\u003e\n\n\u003cp\u003eTwo sloped faces forming an A, an insulated cabinet, dimensions of 14-1\/2 × 20 × 21 in, a net weight of 40 lb. The connections are 3\/8 in on the liquid side and 3\/4 in on the suction side. The metering device is a piston type: a calibrated orifice controls the flow of refrigerant to the coil, with no moving parts to maintain.\u003c\/p\u003e\n\n\u003cp\u003eAmeristar lists several installation positions: upflow, downflow, or horizontal left or right. Depending on where the furnace is, we choose the one that keeps the drain properly sloped and the filter access clear.\u003c\/p\u003e\n\n\u003ch3\u003eThe certified match, explained without jargon\u003c\/h3\u003e\n\n\u003cp\u003eA coil does not get an efficiency rating on its own. The rating belongs to a trio: a specific coil, a specific outdoor unit and the AHRI number that links them. That is where the published SEER2, EER2 and HSPF2 ratings are found. Before ordering, we confirm this number in the AHRI directory.\u003c\/p\u003e\n\n\u003cp\u003eFor you, the consequence is practical: when comparing two quotes, ask for the AHRI number of each. If the numbers differ, the efficiency figures cannot be compared. If one quote gives none, ask the question.\u003c\/p\u003e\n\n\u003ch3\u003eThis model among its neighbours\u003c\/h3\u003e\n\n\u003cp\u003eIn the 4MXC series, three other models exist. All use R-410A and a piston. Here is how to tell them apart:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e4MXCA001AC6HCA\u003c\/strong\u003e: 1.5 to 2.5 tons, 14-1\/2 in. Same width as this one, a slightly lower capacity range, for mid-sized homes.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e4MXCA003AC6HCA\u003c\/strong\u003e (this page): 1.5 to 3 tons, 14-1\/2 in. The choice for a narrow furnace and a house that needs a wider range.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e4MXCB004AC6HCA\u003c\/strong\u003e: 1.5 to 3 tons, 17-1\/2 in. Same capacity range, wider cabinet.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e4MXCC009AC6HCA\u003c\/strong\u003e: 3.5 to 5 tons, 21 in. For large homes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eIn other words, the 4MXCA003AC6HCA and the 4MXCB004AC6HCA have the same nominal capacity: only the width of the cabinet separates them. Your furnace decides, not your preference.\u003c\/p\u003e\n\n\u003ch3\u003ePoints to clarify before buying\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eThe coil runs on R-410A and is paired with an outdoor unit using the same refrigerant.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the matched system, never to the coil taken separately.\u003c\/li\u003e\n\u003cli\u003eThe coil is 14-1\/2 in wide: we check the furnace before ordering.\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the system's airflow.\u003c\/li\u003e\n\u003cli\u003eAmeristar states that some certified combinations of this older-generation coil require a TXV kit ordered separately. We check this for your match.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical sheet\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eManufacturer: Ameristar, model 4MXCA003AC6HCA\u003c\/li\u003e\n\u003cli\u003eType: evaporator coil with cabinet\u003c\/li\u003e\n\u003cli\u003eNominal size: 1.5 to 3 tons (36,000 BTU\/h)\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-410A\u003c\/li\u003e\n\u003cli\u003eMetering device: piston\u003c\/li\u003e\n\u003cli\u003eConnections: 3\/8 in liquid, 3\/4 in suction\u003c\/li\u003e\n\u003cli\u003eCondensate drain: 3\/4 in NPT\u003c\/li\u003e\n\u003cli\u003eDimensions W × H × D: 14-1\/2 × 20 × 21 in\u003c\/li\u003e\n\u003cli\u003eNet weight: 40 lb\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy go with AirGreen\u003c\/h3\u003e\n\n\u003cp\u003eWe are a family-owned heating and cooling company that has been based in Montreal for more than fifteen years. Refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. Our installation day includes measuring the furnace, checking the panel, installing the coil in the plenum, brazing the piping, the nitrogen leak test, the vacuum, connecting the drain and the thermostat, then commissioning with airflow adjustment.\u003c\/p\u003e\n\n\u003ch3\u003eQuick answers\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eDoes it heat?\u003c\/strong\u003e Yes, with a heat pump. With a central air conditioner, the function is cooling.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCan my old air conditioner stay?\u003c\/strong\u003e Rarely. The outdoor unit must match the coil and the R-410A, and we install the whole set.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat happens to the furnace?\u003c\/strong\u003e It stays in place as backup heat.\u003c\/p\u003e\n\n\u003ch3\u003eThree home scenarios where it fits in\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eThe seventies-era bungalow in Longueuil.\u003c\/strong\u003e Electric furnace in the basement, old sheet-metal ducts, a window air conditioner in every bedroom. The coil is added to the plenum, an outdoor unit goes on a pad behind the house, and the system replaces the window units and a good part of the electric heating all at once.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eThe Laval two-storey with a well-insulated upper floor.\u003c\/strong\u003e Cool air finally reaches the upstairs bedrooms, which the old portable units did poorly. The 1.5 to 3 ton range leaves some margin if the house gets a lot of afternoon sun.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eThe North Shore house expanded in stages.\u003c\/strong\u003e A living room addition, a half-finished basement: the load calculation says whether the nominal range is enough, or whether we need to look at the large size in the same series.\u003c\/p\u003e\n\n\u003ch3\u003eWhat we do not promise\u003c\/h3\u003e\n\n\u003cp\u003eWe promise neither an efficiency rating without an AHRI number, nor a grant before we have checked the list, nor that a coil will save ducts in poor condition. We prefer a customer who knows exactly what they are buying to one who is surprised by the bill. If the ducts leak or are too narrow, we say so in the written quote.\u003c\/p\u003e\n\n\u003ch3\u003eMaintenance after installation\u003c\/h3\u003e\n\n\u003cp\u003eThe coil needs little attention: a clean filter, a clear condensate drain, a glance at the cabinet insulation. We explain each step at commissioning, and we are happy to come back if the pan overflows or the air seems less cool than before.\u003c\/p\u003e\n\n\u003ch3\u003eGrants\u003c\/h3\u003e\n\n\u003cp\u003eHydro-Québec programs apply to the complete system, never to the coil alone. When we prepare the quote, we check the match against the official list, according to the installation date, then explain what applies to your case.\u003c\/p\u003e\n\n\u003ch3\u003eRequest an estimate\u003c\/h3\u003e\n\n\u003cp\u003eThe on-site estimate is free: furnace measurements, a review of the electrical service, and a written quote for the complete Ameristar system. To spread out the expense, \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003efinancing\u003c\/a\u003e is offered.\u003c\/p\u003e\n","brand":"Ameristar","offers":[{"title":"Default Title","offer_id":68402721456420,"sku":"4MXCA003AC6HCA","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_AMERISTAR_4MXC_4MXCA003AC6HCA_00_1_5_A_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765750","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-ameristar-4mxca003ac6hca-a-1-5-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}