{"product_id":"serpentin-devaporateur-ameristar-5mxcb004ac6hca-a-1-5-a-3-tonnes","title":"AMERISTAR 5MXCB004AC6HCA Evaporator A-Coil | 1.5 to 3 Tons","description":"\u003ch2\u003e5MXCB004AC6HCA coil: 17-1\/2 in wide, 20 in high, for the mid-size furnace\u003c\/h2\u003e\n\u003ch3\u003eA typical measuring visit, from start to finish\u003c\/h3\u003e\n\u003cp\u003ePicture a two-storey home on the South Shore with a gas or electric furnace in the basement, an old central air conditioner that is wheezing, and a family thinking about a heat pump. The AirGreen technician arrives with a tape measure, a flashlight and a list of questions. Before even talking about tons, he measures the width of the furnace cabinet. If it is 17-1\/2 in, the \u003cstrong\u003eAmeristar 5MXCB004AC6HCA evaporator coil\u003c\/strong\u003e comes straight into the discussion.\u003c\/p\u003e\n\u003cp\u003eThis cased coil from the 5MXC series covers the 1.5 to 3 ton size (36,000 BTU\/h), uses \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e and mounts on the furnace to form a central system with an Ameristar outdoor unit. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhat sets it apart from its slimmer neighbour?\u003c\/h3\u003e\n\u003cp\u003eOn paper, the 5MXCB004AC6HCA and the 5MXCA003AC6HCA offer the same nominal capacity. The difference is width: 17-1\/2 in here, 14-1\/2 in for its smaller sibling. This model's full size is 17-1\/2 × 20 × 21 in, with a net weight of 46 lb.\u003c\/p\u003e\n\u003cp\u003eIn practice, this means it mounts directly on a mid-size furnace, without having to narrow or widen the plenum. It seems like a minor detail, but it saves hours of sheet-metal work and reduces the points where air can leak.\u003c\/p\u003e\n\n\u003ch3\u003eHow a coil works, without the jargon\u003c\/h3\u003e\n\u003cp\u003eThe outdoor unit sends liquid refrigerant indoors. Inside the coil tubes, that liquid evaporates and absorbs heat from the air passing through. The cooled air, relieved of some of its moisture, heads back into the ducts. The condensed moisture runs into the pan and leaves through the 3\/4 in NPT drain connection.\u003c\/p\u003e\n\u003cp\u003eThe refrigerant travels through two copper lines: a 3\/8 in liquid line connection and a 3\/4 in suction line connection. These are the sizes our technicians braze on site.\u003c\/p\u003e\n\n\u003ch3\u003eThe role of the piston\u003c\/h3\u003e\n\u003cp\u003eEvery coil in the series has a piston-type metering device. It is a small calibrated orifice at the coil inlet that limits the flow of refrigerant. Unlike an adjustable valve, it does not move, so its performance depends on a good match with the outdoor unit and on a refrigerant charge carefully adjusted at start-up.\u003c\/p\u003e\n\n\u003ch3\u003eAdding a heat pump to an existing furnace\u003c\/h3\u003e\n\u003cp\u003eThe \"add-on\" scenario appeals because it keeps most of your current equipment:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe blower, filters and existing ducts stay in use;\u003c\/li\u003e\n\u003cli\u003ethe outdoor unit is added beside the house;\u003c\/li\u003e\n\u003cli\u003ethe furnace takes over when the outdoor temperature drops below the threshold that we set with you.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf the outdoor unit is a plain air conditioner, you will only get cooling, but the coil will still be new and suited to the new refrigerant.\u003c\/p\u003e\n\n\u003ch3\u003ePermitted installation positions\u003c\/h3\u003e\n\u003cp\u003eThe manufacturer describes this model as multi-position: upflow, downflow, horizontal left or right. In practice, the furnace in your basement determines the position. We always confirm the airflow direction and the access to the drain before fastening the cabinet.\u003c\/p\u003e\n\n\u003ch3\u003eThe technical features at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel: 5MXCB004AC6HCA, cased evaporator coil;\u003c\/li\u003e\n\u003cli\u003eseries: 5MXC;\u003c\/li\u003e\n\u003cli\u003enominal size: 1.5 to 3 tons (36,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003edimensions (W × H × D): 17-1\/2 × 20 × 21 in;\u003c\/li\u003e\n\u003cli\u003enet weight: 46 lb;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in liquid, 3\/4 in suction;\u003c\/li\u003e\n\u003cli\u003edrain: 3\/4 in NPT;\u003c\/li\u003e\n\u003cli\u003emetering device: piston;\u003c\/li\u003e\n\u003cli\u003eleak detection: \"R454B Refrigerant Mitigation Sensor\" and MCB kit shown on the dimensional drawing (COR-PSD013A-EN); function not described.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhich model in the series for which furnace?\u003c\/h3\u003e\n\u003cp\u003eTo decide, here are the benchmarks taken from each model's data sheet:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e5MXCA003AC6HCA\u003c\/strong\u003e: 1.5 to 3 tons, 14-1\/2 in. The one to choose for a small furnace.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5MXCB004AC6HCA\u003c\/strong\u003e (this one): 1.5 to 3 tons, 17-1\/2 in.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5MXCB006AC6HCA\u003c\/strong\u003e: same 17-1\/2 in width, but the size goes up to 3.5 tons.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5MXCC005AC6HCA\u003c\/strong\u003e and \u003cstrong\u003e5MXCC007AC6HCA\u003c\/strong\u003e: 21 in wide, at 1.5 to 3 tons and 1.5 to 3.5 tons respectively.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5MXCC009AC6HCA\u003c\/strong\u003e: 21 in, 3 to 5 tons.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5MXCD008AC6HCA\u003c\/strong\u003e: 24-1\/2 in, 3 to 3.5 tons.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e5MXCD010AC6HCA\u003c\/strong\u003e: 24-1\/2 in, 3 to 5 tons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf your furnace is 17-1\/2 in wide and the need is around 3 tons or less, the 5MXCB004AC6HCA is the natural choice. If the assessment points to a heavier load, the 5MXCB006AC6HCA offers the same width with a larger size.\u003c\/p\u003e\n\n\u003ch3\u003ePairing and ratings\u003c\/h3\u003e\n\u003cp\u003eThis coil is paired with an Ameristar outdoor unit of the same capacity and the same refrigerant. The performance ratings (SEER2, EER2, HSPF2) are not those of the coil: they belong to the certified system identified by an AHRI number. We confirm that number before ordering. Ameristar lists AHRI-certified coils with Trane, American Standard, RunTru and Ameristar outdoor units (Trane COR-PSD013B-EN), with no published ENERGY STAR pairing under the 5MXC prefix.\u003c\/p\u003e\n\n\u003ch3\u003eHow our installation goes\u003c\/h3\u003e\n\u003cp\u003eAirGreen has been a family-run \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company in Montreal for more than fifteen years, and our refrigeration, ventilation and electrical work falls under our RBQ licence 5645-9605-01. For this system:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003esetting the coil in the plenum, with an insulated transition if needed, then sealing the duct connections;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit, brazing the piping, nitrogen pressure test and evacuation;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003estart-up, airflow adjustment and a walkthrough at the house.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan it heat?\u003c\/strong\u003e Yes, with a heat pump. With a central air conditioner, it only cools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my current air conditioner?\u003c\/strong\u003e Generally not. The coil runs on R-454B and must be paired with the outdoor unit specified by the manufacturer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMy furnace is not the right width. What can I do?\u003c\/strong\u003e We measure it and, if needed, build an insulated transition on site.\u003c\/p\u003e\n\n\u003ch3\u003eWho is this size best for?\u003c\/h3\u003e\n\u003cp\u003eThe classic profile: a mid-size home, a mid-width furnace and an owner who wants to replace a tired air conditioner without turning the basement upside down. Families torn between window units and a central system will find a reasonable compromise here. The coil needs no plenum modification and no new duct system, if the furnace is the right width.\u003c\/p\u003e\n\u003cp\u003eIf, on the other hand, your furnace has already been replaced by a wider model, or if you plan to do so, let's talk about it at the visit: it is better to choose the coil for the equipment you will have tomorrow.\u003c\/p\u003e\n\u003ch3\u003eWhat to check before placing an order\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B requires an outdoor unit with the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe blower must be able to deliver the system's airflow.\u003c\/li\u003e\n\u003cli\u003eThe 17-1\/2 in width must match the furnace.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIncentives and financing\u003c\/h3\u003e\n\u003cp\u003eEligibility for Hydro-Québec programs depends on the complete system, not on the coil alone. We consult the official list when we prepare your quote, depending on the installation date.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Ameristar system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Ameristar","offers":[{"title":"Default Title","offer_id":68402711560484,"sku":"5MXCB004AC6HCA","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_AMERISTAR_5MXC_5MXCB004AC6HCA_00_1_5_A_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765751","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-ameristar-5mxcb004ac6hca-a-1-5-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}