{"product_id":"serpentin-devaporateur-ameristar-5mxcb006ac6hca-a-1-5-a-3-5-tonnes","title":"AMERISTAR 5MXCB006AC6HCA Evaporator A-Coil | 1.5 to 3.5 Tons","description":"\u003ch2\u003e5MXCB006AC6HCA coil: 26 in high and a size that climbs to 3.5 tons\u003c\/h2\u003e\n\u003cp\u003eWhat stands out first about the \u003cstrong\u003eAmeristar 5MXCB006AC6HCA evaporator coil\u003c\/strong\u003e is its height: 26 in, which is clearly more than the two most compact models in the same series. That extra height holds a larger heat-exchange surface, and it is what lets the size extend from 1.5 to 3.5 tons (42,000 BTU\/h). The width stays at 17-1\/2 in, the depth at 21 in, and the net weight reaches 57 lb.\u003c\/p\u003e\n\u003cp\u003eIt runs on \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e and mounts on a furnace to form a central system with an Ameristar outdoor unit. We install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eHeight: the point too often forgotten\u003c\/h3\u003e\n\u003cp\u003eWhen replacing a coil, people look at width, then capacity. Few think about the space above the furnace. Yet a 26 in tall cabinet adds height to the whole assembly. Between the top of the furnace and the basement ceiling, there has to be room for the cabinet, the supply plenum and service access.\u003c\/p\u003e\n\u003cp\u003eDuring the visit, we measure that distance and look for beams, pipes and cables that could be in the way. In a low basement, a horizontal position can sometimes be used, which the manufacturer allows for this model just like the upflow and downflow positions.\u003c\/p\u003e\n\n\u003ch3\u003eWhy a larger size needs more air\u003c\/h3\u003e\n\u003cp\u003eA higher-capacity coil cools a larger volume of air. For the system to deliver what its data sheet promises, the furnace blower has to push more airflow than a small size needs. So we check:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe capacity of the existing blower;\u003c\/li\u003e\n\u003cli\u003ethe size of the supply plenum;\u003c\/li\u003e\n\u003cli\u003ethe condition and sizing of the return ducts;\u003c\/li\u003e\n\u003cli\u003ethe filter, which has to let air through without choking it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA coil that is too big for a weak blower can freeze up or leave the house uneven. The check is done before the order, not after.\u003c\/p\u003e\n\n\u003ch3\u003eTwo-storey homes, bungalows and large townhouses\u003c\/h3\u003e\n\u003cp\u003eThe 1.5 to 3.5 ton size is meant for homes where the ducts serve many rooms: two-storey houses, large bungalows, deep townhouses. It is a mid-range model that leaves some margin if you plan to expand, finish a basement or redo the insulation.\u003c\/p\u003e\n\n\u003ch3\u003eThe piping: two possible suction line diameters\u003c\/h3\u003e\n\u003cp\u003eThe liquid line connection is 3\/8 in. For the suction line, the manufacturer's data sheet lists 3\/4 in or 7\/8 in, depending on the pairing. The diameter used depends on the outdoor unit chosen and on the length of piping between it and the furnace. We confirm this detail before cutting the copper. The condensate drain is 3\/4 in NPT.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the data sheet says\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel: 5MXCB006AC6HCA, cased evaporator coil, 5MXC series;\u003c\/li\u003e\n\u003cli\u003enominal size: 1.5 to 3.5 tons (42,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003edimensions (W × H × D): 17-1\/2 × 26 × 21 in;\u003c\/li\u003e\n\u003cli\u003enet weight: 57 lb;\u003c\/li\u003e\n\u003cli\u003eliquid line connection: 3\/8 in; suction line: 3\/4 in or 7\/8 in;\u003c\/li\u003e\n\u003cli\u003econdensate drain: 3\/4 in NPT;\u003c\/li\u003e\n\u003cli\u003emetering device: piston;\u003c\/li\u003e\n\u003cli\u003epositions: upflow, downflow, horizontal left or right;\u003c\/li\u003e\n\u003cli\u003eleak detection: \"R454B Refrigerant Mitigation Sensor\" and MCB kit shown on the dimensional drawing (COR-PSD013A-EN); function not described.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThis one or the 5MXCB004AC6HCA?\u003c\/h3\u003e\n\u003cp\u003eThese two models have the same 17-1\/2 in width. The 5MXCB004AC6HCA is limited to 1.5 to 3 tons, while this one goes up to 3.5. If your furnace suits both, the decision rests on your home's load, which the on-site assessment lets us calculate, and on the available height.\u003c\/p\u003e\n\u003cp\u003eHere are the other models in the series, to put this one in context:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e5MXCA003AC6HCA: 14-1\/2 in, 1.5 to 3 tons;\u003c\/li\u003e\n\u003cli\u003e5MXCC005AC6HCA: 21 in, 1.5 to 3 tons;\u003c\/li\u003e\n\u003cli\u003e5MXCC007AC6HCA: 21 in, 1.5 to 3.5 tons;\u003c\/li\u003e\n\u003cli\u003e5MXCC009AC6HCA: 21 in, 3 to 5 tons;\u003c\/li\u003e\n\u003cli\u003e5MXCD008AC6HCA: 24-1\/2 in, 3 to 3.5 tons;\u003c\/li\u003e\n\u003cli\u003e5MXCD010AC6HCA: 24-1\/2 in, 3 to 5 tons.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eHeat pump or air conditioner?\u003c\/h3\u003e\n\u003cp\u003ePaired with a heat pump, the coil cools in summer and heats in winter through the same ducts. The furnace stays in place as backup heating for the coldest days, at a threshold that we set with you. Paired with a central air conditioner, it only cools. In both cases, the outdoor unit must use the same refrigerant as the coil.\u003c\/p\u003e\n\n\u003ch3\u003eThe ratings belong to the system\u003c\/h3\u003e\n\u003cp\u003eThe coil has no efficiency rating of its own. The SEER2, EER2 and HSPF2 ratings are tied to the certified system, identified by an AHRI number. Ameristar lists AHRI-certified coils with Trane, American Standard, RunTru and Ameristar outdoor units (Trane COR-PSD013B-EN), and no published ENERGY STAR pairing under the 5MXC prefix. We validate the pairing in the directory before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eOur work on site\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-run \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years; its refrigeration, ventilation and electrical work is covered by RBQ licence 5645-9605-01. On this taller model, the installation includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003echecking the available height, the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003esetting the cabinet, sealing the duct connections and, if needed, an insulated transition;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit, brazing the piping, nitrogen pressure test and evacuation;\u003c\/li\u003e\n\u003cli\u003ethe condensate drain, the thermostat and the airflow adjustment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePoints to confirm before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe outdoor unit must use R-454B and be installed along with the coil.\u003c\/li\u003e\n\u003cli\u003eThe 17-1\/2 in width and the 26 in height must fit your furnace and your basement.\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the system's airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhy height does not tell the whole story about comfort\u003c\/h3\u003e\n\u003cp\u003eA taller coil is not a guarantee of comfort in itself. What counts is the balance among three elements: the home's actual load, the airflow the blower can sustain and the quality of the duct system. If one of the three is weak, the other two cannot make up for it. We would rather spend an extra hour observing the house than promise a result that the duct system cannot deliver.\u003c\/p\u003e\n\u003cp\u003eIn North Shore and Laval homes built with long ducts under concrete floors, for example, the return air is often the weak point. An extra return grille or a larger-diameter duct can change comfort more than a bigger coil.\u003c\/p\u003e\n\u003ch3\u003eMaintenance after installation\u003c\/h3\u003e\n\u003cp\u003eA cased coil is simple to maintain: a clean filter, a clear drain and an annual check are enough to keep the system in good shape. We show you where the condensate drain is, how to recognize a clogged filter and when to call us. The pan must stay dry between cycles and the water must flow freely to the drain.\u003c\/p\u003e\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs assess the complete system, not the coil alone. We check the pairing against the official list when we prepare your quote and tell you what applies depending on the installation date.\u003c\/p\u003e\n\n\u003ch3\u003eEstimate and financing\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace and the available height, check the electrical service and give you a written quote for the complete Ameristar system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Ameristar","offers":[{"title":"Default Title","offer_id":68402715033892,"sku":"5MXCB006AC6HCA","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_AMERISTAR_5MXC_5MXCB006AC6HCA_00_1_5_A_3_5_TONNES_42000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765751","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-ameristar-5mxcb006ac6hca-a-1-5-a-3-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}