{"product_id":"serpentin-devaporateur-ameristar-5mxcc009ac6hca-a-3-a-5-tonnes","title":"AMERISTAR 5MXCC009AC6HCA Evaporator A-Coil | 3 to 5 Tons","description":"\u003ch2\u003e5MXCC009AC6HCA: the 3 to 5 ton coil for large homes, 21 in wide and 30 in high\u003c\/h2\u003e\n\u003cp\u003eWhen a home spreads over three levels, the kitchen opens onto a big living room and the upper floor gets sun all day, a small coil is no longer enough. The \u003cstrong\u003eAmeristar 5MXCC009AC6HCA evaporator coil\u003c\/strong\u003e meets that need with a 3 to 5 ton size (60,000 BTU\/h), a cabinet 21 in wide, 30 in high and 21 in deep, and a net weight of 82 lb.\u003c\/p\u003e\n\u003cp\u003eIt runs on \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e, mounts on a furnace or blower cabinet and is paired with an Ameristar outdoor unit of the same capacity. We work in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eA heavy coil: what that changes at installation\u003c\/h3\u003e\n\u003cp\u003eAt 82 lb, this is the first model in the series where handling becomes a real question. You do not carry it down a basement staircase alone. We plan for two technicians, a clear path and, when needed, a solid support under the cabinet. The 30 in height also calls for vertical clearance, which we measure at the visit, along with the plenum route and the access to the drain.\u003c\/p\u003e\n\u003cp\u003eThe manufacturer lists upflow, downflow and horizontal (left or right) positions. In a home with a low ceiling, the horizontal position can save the day.\u003c\/p\u003e\n\n\u003ch3\u003eWhy a large home needs serious airflow\u003c\/h3\u003e\n\u003cp\u003eA 3 to 5 ton size moves a lot of air. If the furnace blower is undersized, or if the return ducts are too narrow, the coil performs poorly: air circulates badly, some rooms stay hot and the house feels unbalanced. That is why we always inspect:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ethe blower's power and its motor;\u003c\/li\u003e\n\u003cli\u003ethe supply plenum and its connections;\u003c\/li\u003e\n\u003cli\u003ethe return air paths, their number and their cross-section;\u003c\/li\u003e\n\u003cli\u003ethe electrical panel, which must accommodate a larger outdoor unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePiping and condensate\u003c\/h3\u003e\n\u003cp\u003eThe liquid line connection is 3\/8 in. The suction line can be 3\/4 in or 7\/8 in depending on the outdoor unit chosen and the length of the run. On a large coil that produces a lot of condensate, the 3\/4 in NPT drain must have a firm slope and stay accessible for maintenance.\u003c\/p\u003e\n\n\u003ch3\u003e5MXCC009AC6HCA specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased evaporator coil, 5MXC series;\u003c\/li\u003e\n\u003cli\u003enominal size: 3 to 5 tons (60,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003edimensions (W × H × D): 21 × 30 × 21 in;\u003c\/li\u003e\n\u003cli\u003enet weight: 82 lb;\u003c\/li\u003e\n\u003cli\u003econnections: 3\/8 in liquid, 3\/4 in or 7\/8 in suction;\u003c\/li\u003e\n\u003cli\u003econdensate drain: 3\/4 in NPT;\u003c\/li\u003e\n\u003cli\u003emetering device: piston;\u003c\/li\u003e\n\u003cli\u003eleak detection: \"R454B Refrigerant Mitigation Sensor\" and MCB kit shown on the dimensional drawing (COR-PSD013A-EN); function not described.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCompared with the other models in the series\u003c\/h3\u003e\n\u003cp\u003eThe 5MXCC009AC6HCA is one of the two models that go up to 5 tons. The other is the \u003cstrong\u003e5MXCD010AC6HCA\u003c\/strong\u003e, which offers the same 3 to 5 ton range but at 24-1\/2 in wide. The choice between the two depends on your furnace: 21 in here, 24-1\/2 in there.\u003c\/p\u003e\n\u003cp\u003eLower on the scale:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e5MXCC007AC6HCA, 21 in, 1.5 to 3.5 tons;\u003c\/li\u003e\n\u003cli\u003e5MXCC005AC6HCA, 21 in, 1.5 to 3 tons;\u003c\/li\u003e\n\u003cli\u003e5MXCD008AC6HCA, 24-1\/2 in, 3 to 3.5 tons;\u003c\/li\u003e\n\u003cli\u003e5MXCB006AC6HCA and 5MXCB004AC6HCA, 17-1\/2 in;\u003c\/li\u003e\n\u003cli\u003e5MXCA003AC6HCA, 14-1\/2 in.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf the assessment shows that your home does not need more than 3.5 tons, a smaller model will be the wiser choice: an oversized coil runs short cycles and dries the air poorly.\u003c\/p\u003e\n\n\u003ch3\u003eA heat pump on a large home\u003c\/h3\u003e\n\u003cp\u003eIn a large home, the heat pump takes a significant share of the heating from fall to spring. The furnace stays there for the coldest days: it keeps its blower, its filters and its backup role, starting at a temperature threshold that we set with you. In summer, the same installation replaces a whole collection of window units with a single system that serves every floor.\u003c\/p\u003e\n\n\u003ch3\u003eThe certified pairing\u003c\/h3\u003e\n\u003cp\u003eThe coil has no efficiency rating of its own. The SEER2, EER2 and HSPF2 ratings are tied to the certified system, linked by an AHRI number. Ameristar lists AHRI-certified coils with Trane, American Standard, RunTru and Ameristar outdoor units (Trane COR-PSD013B-EN), and no published ENERGY STAR pairing under the 5MXC prefix. We check that number before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eOur installation\u003c\/h3\u003e\n\u003cp\u003eAirGreen has been a family-run \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. For a system of this size, we first check the furnace, the blower and the electrical service, then set the cabinet carefully, seal the duct connections, install the outdoor unit on its pad, braze the piping, pressure-test everything with nitrogen, pull a vacuum, connect the drain and the thermostat, and then adjust the airflow.\u003c\/p\u003e\n\n\u003ch3\u003eThe question of the electrical panel and the outdoor location\u003c\/h3\u003e\n\u003cp\u003eA large outdoor unit needs a suitable circuit and a clear location: open air around it, a level pad, access for service and a reasonable distance from the coil to limit the length of piping. In the dense neighbourhoods of Montreal, Laval or Longueuil, where yards are narrow, we look for the location that respects the neighbours, the unit's ventilation and winter snow constraints.\u003c\/p\u003e\n\u003cp\u003eOn the North Shore and South Shore, where lots are often wider, the solution is simpler, but the panel check stays the same: we confirm the capacity of the electrical service before preparing the quote.\u003c\/p\u003e\n\u003ch3\u003eMaintaining a large coil\u003c\/h3\u003e\n\u003cp\u003eThe bigger the coil, the more condensate it produces in summer. A clear drain and a clean pan are therefore essential. We advise having the whole assembly checked once a year, replacing the filter regularly and watching for any trace of water around the furnace. A simple check before the hot season avoids most unpleasant surprises.\u003c\/p\u003e\n\u003ch3\u003eAn example on the North Shore\u003c\/h3\u003e\n\u003cp\u003eA North Shore couple is expanding their home: an addition on the ground floor, a finished basement and a large bay window. Their old air conditioner can no longer keep up. The furnace is 21 in wide. The load calculation exceeds the range of the two other models of that width, and the 5MXCC009AC6HCA becomes the only coherent choice, provided the blower and the return air paths keep up.\u003c\/p\u003e\n\u003ch3\u003eWhat to check before choosing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe outdoor unit must use R-454B and be installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe furnace must be 21 in wide, with the required height above it.\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the system's airflow.\u003c\/li\u003e\n\u003cli\u003eThe support must handle 82 lb.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs assess the complete system, not the coil alone. We check the pairing against the official list and tell you what applies depending on the installation date.\u003c\/p\u003e\n\n\u003ch3\u003eEstimate and financing\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Ameristar system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Ameristar","offers":[{"title":"Default Title","offer_id":68402717688100,"sku":"5MXCC009AC6HCA","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_AMERISTAR_5MXC_5MXCC009AC6HCA_00_3_A_5_TONNES_60000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765752","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-ameristar-5mxcc009ac6hca-a-3-a-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}