{"product_id":"serpentin-devaporateur-ameristar-5mxcd008ac6hca-a-3-a-3-5-tonnes","title":"AMERISTAR 5MXCD008AC6HCA Evaporator A-Coil | 3 to 3.5 Tons","description":"\u003ch2\u003e5MXCD008AC6HCA: a large 24-1\/2 in cabinet for a 3 to 3.5 ton load\u003c\/h2\u003e\n\u003ch3\u003eThe coil you choose because the furnace is wide\u003c\/h3\u003e\n\u003cp\u003eSome furnaces are wide without the house being enormous. You find them when an older high-airflow unit has been kept, or when a large blower cabinet serves a mid-size home. For those cases, the \u003cstrong\u003eAmeristar 5MXCD008AC6HCA evaporator coil\u003c\/strong\u003e offers the 24-1\/2 in width with a narrow capacity range, 3 to 3.5 tons (42,000 BTU\/h).\u003c\/p\u003e\n\u003cp\u003eIts dimensions are 24-1\/2 in wide, 26 in high and 21 in deep, for a net weight of 64 lb. It runs on \u003cstrong\u003eR-454B refrigerant\u003c\/strong\u003e and is paired with an Ameristar outdoor unit of the same capacity. We install it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eA capacity range that starts higher\u003c\/h3\u003e\n\u003cp\u003eThe narrower models in the series start at 1.5 tons. This one starts at 3 tons. That is an important difference: it is meant for homes whose cooling load already sits in the upper part of the usual residential scale, not for those torn between a small and a medium size. If your assessment points to a lighter load, a smaller model will be better suited.\u003c\/p\u003e\n\n\u003ch3\u003eReading the data sheet numbers without getting lost\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003emodel: 5MXCD008AC6HCA, cased evaporator coil, 5MXC series;\u003c\/li\u003e\n\u003cli\u003enominal size: 3 to 3.5 tons (42,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003edimensions (W × H × D): 24-1\/2 × 26 × 21 in;\u003c\/li\u003e\n\u003cli\u003enet weight: 64 lb;\u003c\/li\u003e\n\u003cli\u003eliquid line connection: 3\/8 in; suction line: 3\/4 in or 7\/8 in;\u003c\/li\u003e\n\u003cli\u003econdensate drain: 3\/4 in NPT;\u003c\/li\u003e\n\u003cli\u003emetering device: piston;\u003c\/li\u003e\n\u003cli\u003epositions: upflow, downflow, horizontal left or right;\u003c\/li\u003e\n\u003cli\u003eleak detection: \"R454B Refrigerant Mitigation Sensor\" and MCB kit shown on the dimensional drawing (COR-PSD013A-EN); function not described.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eNext to its twin, the 5MXCD010AC6HCA\u003c\/h3\u003e\n\u003cp\u003eThese two models share the 24-1\/2 in width, but they are the only ones in the series that reach this far in width. The 5MXCD010AC6HCA covers 3 to 5 tons; the 5MXCD008AC6HCA, 3 to 3.5 tons. Choosing the second means recognizing that the house does not need the large range and that the furnace dictates the width.\u003c\/p\u003e\n\u003cp\u003eHere is the full picture for comparison:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e14-1\/2 in: 5MXCA003AC6HCA, 1.5 to 3 tons;\u003c\/li\u003e\n\u003cli\u003e17-1\/2 in: 5MXCB004AC6HCA (1.5 to 3 tons) and 5MXCB006AC6HCA (1.5 to 3.5 tons);\u003c\/li\u003e\n\u003cli\u003e21 in: 5MXCC005AC6HCA, 5MXCC007AC6HCA and 5MXCC009AC6HCA (3 to 5 tons);\u003c\/li\u003e\n\u003cli\u003e24-1\/2 in: 5MXCD008AC6HCA (this one) and 5MXCD010AC6HCA.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn other words, if your furnace is 24-1\/2 in and your need does not exceed 3.5 tons, this model avoids buying a coil bigger than necessary.\u003c\/p\u003e\n\n\u003ch3\u003eAn alternative to the custom transition\u003c\/h3\u003e\n\u003cp\u003eWhen the furnace is wide and a narrower coil is installed, an insulated sheet-metal transition has to be built to connect the two. It is doable, but it adds joints and time. With a coil the same width as the cabinet, the air passes from one to the other without a detour, and there are fewer sealants to keep an eye on over time.\u003c\/p\u003e\n\n\u003ch3\u003eAirflow to check\u003c\/h3\u003e\n\u003cp\u003eEven though the capacity range is more modest than that of its big sibling, the system needs good airflow. We check the blower, the returns and the cross-section of the supply ducts. A cramped duct system gives long cycles and poorly served rooms, whatever coil is set on top.\u003c\/p\u003e\n\n\u003ch3\u003eWinter and summer\u003c\/h3\u003e\n\u003cp\u003eWith a heat pump, the coil cools in summer and heats in winter. The furnace keeps its blower and filters, and serves as backup heating for the coldest days below a threshold that we set with you. With a central air conditioner, it only cools. In both cases, the outdoor unit must use the same refrigerant, R-454B.\u003c\/p\u003e\n\n\u003ch3\u003eRatings and AHRI number\u003c\/h3\u003e\n\u003cp\u003eThe coil has no efficiency rating of its own; the SEER2, EER2 and HSPF2 ratings are those of the certified system. Ameristar lists AHRI-certified coils with Trane, American Standard, RunTru and Ameristar outdoor units (Trane COR-PSD013B-EN), and no published ENERGY STAR pairing under the 5MXC prefix. We validate the AHRI number before ordering, so that the quote reflects what you will receive.\u003c\/p\u003e\n\n\u003ch3\u003eOur work at your home\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-run \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years. Our refrigeration, ventilation and electrical work is covered by RBQ licence 5645-9605-01. For this coil:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ewe measure the furnace and check the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003ewe install the cabinet in the plenum and seal the duct connections;\u003c\/li\u003e\n\u003cli\u003ewe set the outdoor unit, braze the piping, and run the nitrogen pressure test and evacuation;\u003c\/li\u003e\n\u003cli\u003ewe connect the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ewe adjust the airflow and explain how everything works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eQuestions we are often asked\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this coil heat?\u003c\/strong\u003e Yes, when paired with a heat pump. With a central air conditioner, it only cools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I reuse my current outdoor unit?\u003c\/strong\u003e Generally not: the coil runs on R-454B and must be paired with the unit specified by the manufacturer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the furnace still useful?\u003c\/strong\u003e Yes. It keeps its blower and serves as backup for the coldest days.\u003c\/p\u003e\n\n\u003ch3\u003eWhat to check before placing an order\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe outdoor unit must use R-454B and be installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe furnace must be 24-1\/2 in wide, or we build a transition.\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the system's airflow.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAn example of our reasoning during the visit\u003c\/h3\u003e\n\u003cp\u003eTake a South Shore home whose furnace, replaced a few years ago, has a wide cabinet. The owner wants air conditioning without touching the ducts. We measure the cabinet, find that it reaches 24-1\/2 in, then calculate the home's load room by room: orientation, insulation, windows, number of occupants. If the result falls in the 3 to 3.5 ton range, the 5MXCD008AC6HCA is the logical candidate; if it exceeds that range, we move to the 5MXCD010AC6HCA.\u003c\/p\u003e\n\u003cp\u003eAt no point do we propose a model for the sole reason that it is in stock. The choice follows from the measurements, and we give you the details of our calculations with the written quote.\u003c\/p\u003e\n\u003ch3\u003eMaintenance and follow-up\u003c\/h3\u003e\n\u003cp\u003eA coil of this size asks for little attention: a clean filter, a clear drain and an annual check. We recommend checking the condensate drainage in spring and watching for any trace of water near the furnace. If an unusual noise or a drop in comfort appears, call us: an airflow adjustment is often enough to restore things.\u003c\/p\u003e\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs assess the complete system, not the coil alone. We check the pairing against the official list when we prepare your quote and tell you what applies, depending on the installation date.\u003c\/p\u003e\n\n\u003ch3\u003eGet your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Ameristar system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Ameristar","offers":[{"title":"Default Title","offer_id":68402716934436,"sku":"5MXCD008AC6HCA","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_AMERISTAR_5MXC_5MXCD008AC6HCA_00_3_A_3_5_TONNES_42000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765750","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-ameristar-5mxcd008ac6hca-a-3-a-3-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}