{"product_id":"serpentin-devaporateur-arcoaire-evd4x30m17a-v-2-5-tonnes","title":"ARCOAIRE EVD4X30M17A Evaporator V-Coil | 2.5 Tons","description":"\u003ch2\u003eEVD4X30M17A: 2.5 tons and the first 17-1\/2 in cabinet in the Arcoaire series\u003c\/h2\u003e\n\u003cp\u003eIn Arcoaire's EVD4X series, there is a boundary that many homeowners do not notice until the visit: the width of the cabinet. The two smallest models measure 14-3\/16 in. Starting with the \u003cstrong\u003eEVD4X30M17A evaporator coil\u003c\/strong\u003e, the width goes up to 17-1\/2 in. It is also the first model to offer 2.5 tons (30,000 BTU\/h), a mid-range size that suits the medium-sized home, from the two-storey house to the bungalow with a basement.\u003c\/p\u003e\n\u003cp\u003eWe install it on furnaces in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eWhat kind of home is this model made for?\u003c\/h3\u003e\n\u003cp\u003ePicture a two-storey house with a well-insulated upper floor, or a bungalow whose basement stays cool in summer without help. In these homes, the cooling load is higher than in a small unit, without reaching that of a large residence. The 2.5 ton size fills that middle ground.\u003c\/p\u003e\n\u003cp\u003eWe never pick the size by eye. We calculate the load, then compare it with the available options. Sometimes the result falls between two sizes: we then explain which one is the safer choice for the home and why.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the 17-1\/2 in width means\u003c\/h3\u003e\n\u003cp\u003eThe cabinet is 17-1\/2 in wide, 19-7\/16 in high and 20.6 in deep, and weighs 31.2 lb net. These dimensions need to be checked against your furnace before any order. If the furnace is narrower, we build an insulated transition on site. If it is exactly the right width, the installation is direct and the seal is excellent.\u003c\/p\u003e\n\u003cp\u003eThe coil sits in a vertical position, upflow or downflow. It comes in its insulated cabinet, which avoids assembling parts inside a tight plenum.\u003c\/p\u003e\n\n\u003ch3\u003eInside: V shape, TXV and condensate\u003c\/h3\u003e\n\u003cp\u003eThe two faces of the coil form a V: you gain heat exchange surface in a compact volume. The TXV metering device regulates the flow of R-410A entering the tubes. The connections are 3\/8 in on the liquid side and 3\/4 in on the suction side.\u003c\/p\u003e\n\u003cp\u003eCondensation water falls into a sloped PBT pan fitted with 3 sealed plugs; the exact drain diameter is not published by the manufacturer, so we take it on site when we make the connection.\u003c\/p\u003e\n\n\u003ch3\u003eHow the air becomes cool\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe outdoor unit sends the refrigerant to the coil.\u003c\/li\u003e\n\u003cli\u003eIn the tubes, it evaporates and picks up the heat from the air.\u003c\/li\u003e\n\u003cli\u003eThe furnace blower pushes the cooled air through your ducts.\u003c\/li\u003e\n\u003cli\u003eMoisture condenses on the coil and goes to the drain.\u003c\/li\u003e\n\u003cli\u003eIn winter, the system is off and the furnace heats on its own.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe manufacturer reserves this coil for cooling. It pairs with an air conditioner, not a heat pump.\u003c\/p\u003e\n\n\u003ch3\u003ePlacing it in the EVD4X series\u003c\/h3\u003e\n\u003cp\u003eHere is how this model compares with the six others, only on the published points:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEVD4X18M14A\u003c\/strong\u003e (1.5 ton) and \u003cstrong\u003eEVD4X24M14A\u003c\/strong\u003e (2 tons): 14-3\/16 in cabinet, for narrower furnaces and more modest loads.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVD4X36M17A\u003c\/strong\u003e (3 tons) and \u003cstrong\u003eEVD4X42M17A\u003c\/strong\u003e (3.5 tons): the same 17-1\/2 in width as this one, with higher capacities.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVD4X48M24A\u003c\/strong\u003e (4 tons) and \u003cstrong\u003eEVD4X60M24A\u003c\/strong\u003e (5 tons): 24-1\/2 in cabinet, for large homes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn other words, if your furnace is 17-1\/2 in, this model is the entry point for that width: you can move up in capacity without changing the footprint. And if it is narrower but the load calls for 2.5 tons, a custom transition settles the question.\u003c\/p\u003e\n\n\u003ch3\u003eMatching and AHRI number\u003c\/h3\u003e\n\u003cp\u003eA coil has no SEER2 or EER2 rating of its own. These figures belong to the system, that is, a coil and an Arcoaire outdoor unit of the same capacity and the same refrigerant, linked by an AHRI number. We check that number before ordering, so that the ratings promised to you are the ones you get, and so that your comparison of quotes is fair.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my current air conditioner?\u003c\/strong\u003e Generally no: the coil runs on R-410A and must be paired with the outdoor unit intended by the manufacturer. We install the complete system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan this coil also heat?\u003c\/strong\u003e No. For a heat pump, we offer a coil approved for that use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the furnace still useful?\u003c\/strong\u003e Yes: its blower pushes the cool air in summer and it keeps heating the house in winter.\u003c\/p\u003e\n\n\u003ch3\u003eOur work, from the first survey to commissioning\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003esurvey of the furnace, the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003ecoil set in the plenum, tight joints, custom transition if needed;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a pad or bracket, brazed piping, nitrogen test, evacuation;\u003c\/li\u003e\n\u003cli\u003econdensate drain and thermostat connected;\u003c\/li\u003e\n\u003cli\u003eairflow adjustment and demonstration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAirGreen, a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years, works under RBQ licence 5645-9605-01.\u003c\/p\u003e\n\n\u003ch3\u003ePoints to confirm before choosing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-410A: the outdoor unit must use the same refrigerant.\u003c\/li\u003e\n\u003cli\u003eThe 17-1\/2 in width: we compare it with the furnace during the visit.\u003c\/li\u003e\n\u003cli\u003eThe blower: it must deliver the airflow the system requires.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs target heat pumps. This coil, reserved for cooling, does not qualify; eligibility depends on the complete system and the installation date. If this matters to you, we present an eligible heat pump in the same quote.\u003c\/p\u003e\n\n\u003ch3\u003eAbout Arcoaire\u003c\/h3\u003e\n\u003cp\u003eA brand of International Comfort Products, a Carrier subsidiary, Arcoaire is distributed in Quebec by Tecnico. Its QuietComfort DLCURAH heat pump with an Inverter compressor goes with the DL coil; the EVD4X cased V-coil series, for its part, handles air conditioning on a furnace.\u003c\/p\u003e\n\n\u003ch3\u003eAn example of a visit\u003c\/h3\u003e\n\u003cp\u003eTake a suburban two-storey house whose upper floor is hot enough that people sleep in the basement in July. We start with the plenum: width, condition of the seal, access for the blower. Then we move on to the electrical panel and the possible location of the outdoor unit, away from bedroom windows to limit noise.\u003c\/p\u003e\n\u003cp\u003eAt the end of the visit, you receive a written quote that states the coil model, the planned match and any related work. Nothing is hidden in a vague line: if a duct transition is needed, it appears.\u003c\/p\u003e\n\n\u003ch3\u003eNoise, appearance and the yard\u003c\/h3\u003e\n\u003cp\u003eA single outdoor unit replaces several window units. It is installed on a pad or bracket, away from resting areas, and stays out of sight if it is placed with a little thought. Inside, there is nothing to see: the coil is in the plenum, and the existing vents distribute the air. It is a gain in looks as much as in sound.\u003c\/p\u003e\n\n\u003ch3\u003eGet your quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Arcoaire system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Arcoaire","offers":[{"title":"Default Title","offer_id":68402425397540,"sku":"EVD4X30M17A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ARCOAIRE_EVD4X_EVD4X30M17A_00_2_5_TONNES_30000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765559","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-arcoaire-evd4x30m17a-v-2-5-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}