{"product_id":"serpentin-devaporateur-arcoaire-evd4x48m24a-v-4-tonnes","title":"ARCOAIRE EVD4X48M24A Evaporator V-Coil | 4 Tons","description":"\u003ch2\u003eArcoaire EVD4X48M24A: 4 tons in a 24-1\/2 in cabinet for large homes with a furnace\u003c\/h2\u003e\n\u003cp\u003eWhen a home has grown over the years, with an addition at the back, a finished basement or an added floor, the original air conditioning, if there is any, has almost never kept up. The \u003cstrong\u003eArcoaire EVD4X48M24A evaporator coil\u003c\/strong\u003e answers this situation: 4 tons (48,000 BTU\/h), a cabinet 24-1\/2 in wide, R-410A and a TXV metering device. We install it on furnaces in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eMeasure first: the space, not just the capacity\u003c\/h3\u003e\n\u003cp\u003eA coil of this size needs room. Here are the published dimensions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ewidth: 24-1\/2 in;\u003c\/li\u003e\n\u003cli\u003eheight: 22-1\/16 in;\u003c\/li\u003e\n\u003cli\u003edepth: 20.6 in;\u003c\/li\u003e\n\u003cli\u003enet weight: 37 lb.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBefore going further, we check that the plenum, the ceiling height of the mechanical room and the access to the blower allow the cabinet to be fitted without improvisation. If the furnace is narrower, we build an insulated transition on site. If the height is lacking, we say so at the visit rather than at installation time.\u003c\/p\u003e\n\n\u003ch3\u003eWhat 4 tons means for the air network\u003c\/h3\u003e\n\u003cp\u003eAt this capacity, the system has to move a lot of air. Your furnace's blower, its filters and the size of its main ducts determine whether the required airflow is achievable. An undersized network brings noise, poorly served rooms and a coil that works badly.\u003c\/p\u003e\n\u003cp\u003eDuring the visit, we therefore examine the blower and the condition of the filters, and we look at the main ducts. This preparatory work makes the difference between a comfortable system and a disappointing installation.\u003c\/p\u003e\n\n\u003ch3\u003eA multi-storey house, a large bungalow: who is it for?\u003c\/h3\u003e\n\u003cp\u003eThe 4 ton generally serves a two-storey home or a large bungalow with a finished basement. The cooling load is spread over large areas, with many windows and sometimes a sunny room at the back. A single coil on a single furnace is then enough to cool the whole volume, provided the duct network is well balanced.\u003c\/p\u003e\n\u003cp\u003eIn a home where the floors behave very differently, we also discuss damper balancing or zoning, depending on what the furnace can support.\u003c\/p\u003e\n\n\u003ch3\u003eHow it works\u003c\/h3\u003e\n\u003cp\u003eThe V-coil sits in the plenum. Liquid refrigerant arrives through the 3\/8 in line, evaporates in the tubes, picks up heat from the air, then leaves as a gas through the 7\/8 in suction line to the outdoor unit. The condensation water collects in the sloped PBT pan, with its 3 sealed plugs, and goes to the drain (diameter not published, confirmed at installation).\u003c\/p\u003e\n\u003cp\u003eThe coil is installed in a vertical position, upflow or downflow. In winter, the air conditioner is off and the furnace heats the house on its own.\u003c\/p\u003e\n\n\u003ch3\u003eComparing with the other EVD4X models\u003c\/h3\u003e\n\u003cp\u003eThe 24-1\/2 in cabinet is the widest in the series. It is offered in only two models:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEVD4X48M24A\u003c\/strong\u003e: 4 tons (this model);\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEVD4X60M24A\u003c\/strong\u003e: 5 tons, the same width, one step more capacity.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe smaller models have narrower cabinets: \u003cstrong\u003eEVD4X18M14A\u003c\/strong\u003e (1.5 ton) and \u003cstrong\u003eEVD4X24M14A\u003c\/strong\u003e (2 tons) are 14-3\/16 in; \u003cstrong\u003eEVD4X30M17A\u003c\/strong\u003e (2.5 tons), \u003cstrong\u003eEVD4X36M17A\u003c\/strong\u003e (3 tons) and \u003cstrong\u003eEVD4X42M17A\u003c\/strong\u003e (3.5 tons) are 17-1\/2 in. All run on R-410A with a TXV.\u003c\/p\u003e\n\u003cp\u003eIf the 3.5 ton meets the load calculation and your furnace is 17-1\/2 in, there is no reason to move up. If, on the contrary, the furnace is wide and the load is high, the 4 ton is the natural starting point, and the 5 ton is the next choice if the load requires it.\u003c\/p\u003e\n\n\u003ch3\u003eThe certified match and the AHRI number\u003c\/h3\u003e\n\u003cp\u003eThe coil has no efficiency rating of its own. A certified system combines this coil, an Arcoaire outdoor unit of the same capacity and the same refrigerant, and an AHRI number that links them. SEER2 and EER2 ratings apply to that whole set. We confirm the number before ordering, so that the figures promised are the ones you get.\u003c\/p\u003e\n\n\u003ch3\u003eThe installation steps\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003esurvey of the furnace, the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003ecoil installed in the plenum, custom transition if needed, sealed duct connections;\u003c\/li\u003e\n\u003cli\u003eoutdoor unit on a pad or bracket, brazed piping, nitrogen pressure test and evacuation;\u003c\/li\u003e\n\u003cli\u003econdensate drain and thermostat connected;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment, explanation of how it works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company, based in Montreal for more than fifteen years, working under RBQ licence 5645-9605-01 for refrigeration, ventilation and electrical work.\u003c\/p\u003e\n\n\u003ch3\u003eQuestions homeowners ask us\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this coil heat?\u003c\/strong\u003e No. The manufacturer reserves it for cooling; for a heat pump, we offer a coil approved for that use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my current outdoor unit?\u003c\/strong\u003e Generally no: R-410A requires pairing with the outdoor unit intended by the manufacturer. We install the complete system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the furnace keep a role?\u003c\/strong\u003e Yes: it keeps its blower, which pushes the cool air in summer, and it heats the house in winter.\u003c\/p\u003e\n\n\u003ch3\u003eBefore buying, three checks\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe space available for a cabinet 24-1\/2 in wide.\u003c\/li\u003e\n\u003cli\u003eThe blower's ability to deliver the airflow of the complete system.\u003c\/li\u003e\n\u003cli\u003eThe refrigerant: R-410A, from end to end.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eIncentives\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec programs target heat pumps. A coil reserved for cooling does not qualify, and eligibility depends on the complete system and the installation date. If an incentive matters to you, we include an eligible heat pump system in the same quote.\u003c\/p\u003e\n\n\u003ch3\u003eThe Arcoaire brand\u003c\/h3\u003e\n\u003cp\u003eArcoaire is part of International Comfort Products, a Carrier subsidiary, and its distributor in Quebec is Tecnico. The QuietComfort DLCURAH heat pump with an Inverter compressor goes with the DL coil, and the EVD4X cased V-coil serves central air conditioning on a furnace.\u003c\/p\u003e\n\n\u003ch3\u003eZoning and balancing: when a large home poses air challenges\u003c\/h3\u003e\n\u003cp\u003eIn a multi-level home, cool air tends to sink and warm air to rise. The result: the basement turns cool while the upper floor stays warm. Balancing the registers, and sometimes adjusting the duct dampers, can correct a good part of the gap. In other cases, motorized zoning with several thermostats is worth considering, if the furnace and the network allow it.\u003c\/p\u003e\n\u003cp\u003eWe discuss this during the visit and price these options separately, so that you decide with full knowledge.\u003c\/p\u003e\n\n\u003ch3\u003ePlanning the outdoor installation\u003c\/h3\u003e\n\u003cp\u003eA high-capacity outdoor unit takes up space and needs clearance around it to breathe properly. We place it on a stable pad or a wall bracket, at a reasonable distance from windows, patios and property lines. We also protect the piping from impacts and sun exposure, so that the whole installation stays reliable and discreet.\u003c\/p\u003e\n\n\u003ch3\u003eOn-site estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Arcoaire system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Arcoaire","offers":[{"title":"Default Title","offer_id":68402419925284,"sku":"EVD4X48M24A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_ARCOAIRE_EVD4X_EVD4X48M24A_00_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765539","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-arcoaire-evd4x48m24a-v-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}