{"product_id":"serpentin-devaporateur-canair-ceb-24mx1421-a-2-tonnes","title":"CANAIR CEB-24MX1421 Evaporator A-Coil | 2 Tons","description":"\u003ch2\u003eCEB-24MX1421: the narrowest 2-ton Canair evaporator coil, made for townhouse furnaces\u003c\/h2\u003e\n\u003cp\u003eMeasure the furnace in a small Montreal, Longueuil or Laval home and you often find a narrow cabinet squeezed between a water heater and a concrete wall. That is the situation the \u003cstrong\u003eCanair CEB-24MX1421 evaporator coil\u003c\/strong\u003e was designed for: a cased A-coil, rated at 2 tons (24,000 BTU\/h), only 14-1\/2 in wide, running on R-454B refrigerant. It mounts on top of the furnace, in the plenum, and receives refrigerant from the Canair 4CDH2018C21 or 4CDH2024C21 outdoor unit.\u003c\/p\u003e\n\u003cp\u003eOn this page, we look at what this model does in your home, what to measure before you order, and how it compares with the other CEB coils in the series.\u003c\/p\u003e\n\n\u003ch3\u003eWhat a coil does, explained without jargon\u003c\/h3\u003e\n\u003cp\u003eThink of the furnace as a big fan that pushes air through the ducts. The coil is the heat exchanger placed in its path. In summer, cold refrigerant circulates through it and the warm air from your home gives up its heat to it. Moisture condenses on the tubes, drips into the pan and runs to the drain. The air comes out cool and drier.\u003c\/p\u003e\n\u003cp\u003eIn winter, if the outdoor unit is a heat pump, the cycle reverses. The same coil becomes the heat source that warms the air before it heads to the bedrooms. The furnace stays in place for the coldest days.\u003c\/p\u003e\n\n\u003ch3\u003eWhy 14-1\/2 in changes the technical visit\u003c\/h3\u003e\n\u003cp\u003eWidth is the first measurement we take. A 14-1\/2 in coil on a furnace of the same width installs cleanly, with no adapter piece. The insulated cabinet arrives ready to install: it fits the top of the furnace and limits air leaks around the coil.\u003c\/p\u003e\n\u003cp\u003eIf your furnace is wider, we build an insulated transition on site. It is routine work, but it is better to know before the quote. The published dimensions are 14-1\/2 × 18 × 21 in (W × H × D); the 18 in height matters when the basement ceiling is low or a pipe runs just overhead.\u003c\/p\u003e\n\n\u003ch3\u003eTwo certified matches with the outdoor unit\u003c\/h3\u003e\n\u003cp\u003eThe coil is never on its own: it forms a system with an outdoor heat pump from the 4CDH20 range, which uses R-454B and a variable-speed compressor. For the CEB-24MX1421, Canair publishes two combinations.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e4CDH2018C21\u003c\/strong\u003e, AHRI number 216621485: cooling of 18,000 BTU\/h, heating of 19,000 BTU\/h at 47 °F, SEER2 16.1, HSPF2 9.5;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e4CDH2024C21\u003c\/strong\u003e, AHRI number 216621487: cooling of 24,000 BTU\/h, heating of 25,000 BTU\/h at 47 °F, SEER2 16.0, HSPF2 9.5.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe smaller of the two suits well-insulated homes; the second leaves more margin for a townhouse with thin party walls or older windows. We decide after the load calculation, not before.\u003c\/p\u003e\n\n\u003ch3\u003eAn efficiency rating that belongs to the system, not the coil\u003c\/h3\u003e\n\u003cp\u003eThe coil has no SEER2 or HSPF2 rating of its own. Those figures describe the certified system: one specific coil, one specific outdoor unit, and an AHRI number that links them. When two contractors give you quotes, ask for that number. If it differs, the equipment is not the same, even if the prices look alike.\u003c\/p\u003e\n\u003cp\u003eThat number is also the reference for incentive programs. Canair states that all CEB and 4CDH20 pairings are ENERGY STAR cold climate certified, in Canada and in the United States, with a heating capacity at -8.3 °C of 15,200 to 37,800 BTU\/h depending on the pairing.\u003c\/p\u003e\n\n\u003ch3\u003eCEB-24MX1421 or CEB-24MX1721: width decides\u003c\/h3\u003e\n\u003cp\u003eBoth models have the same nominal size of 2 tons, the same R-454B refrigerant, the same TXV expansion valve and the same compatible outdoor units. Only the width changes: 14-1\/2 in here, 17-1\/2 in for the CEB-24MX1721. Choose the one that matches your furnace. If you are torn between the two, the cabinet measurement settles it, not preference.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if the house needs more capacity?\u003c\/h3\u003e\n\u003cp\u003eThe series also offers 3-ton coils in 14-1\/2 in (CEB-36MX1421), 17-1\/2 in (CEB-36MX1721) and 21 in (CEB-36MX2121), paired with 4CDH2030C21 units, as well as 5-ton models in 21 in (CEB-60MX2121) and 24-1\/2 in (CEB-60MX2421). For a townhouse, a 2-ton size is generally well proportioned. An oversized system short-cycles: it cools quickly but removes humidity poorly, and the air stays clammy.\u003c\/p\u003e\n\u003cp\u003eIf our calculation shows you need more, we will tell you plainly. The decision is based on the needs of the house, not on what is in stock.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical specifications at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased evaporator coil, CEB range;\u003c\/li\u003e\n\u003cli\u003enominal size: 2 tons (24,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003erefrigerant: R-454B;\u003c\/li\u003e\n\u003cli\u003eexpansion device: TXV, which regulates the flow of refrigerant sent to the coil;\u003c\/li\u003e\n\u003cli\u003epositions: multi-position;\u003c\/li\u003e\n\u003cli\u003edimensions: 14-1\/2 × 18 × 21 in;\u003c\/li\u003e\n\u003cli\u003emanufacturer warranty: residential, 10 years on the compressor and 10 years on parts; commercial, 5 years and 1 year. A 10-year limited labour warranty is available as an option.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhat it changes in a townhouse, winter and summer\u003c\/h3\u003e\n\u003cp\u003eAn electric baseboard heater turns each kilowatt-hour into an equal amount of heat. A heat pump moves heat from outdoors to indoors and, in mild weather, delivers two to three times more heat than the electricity it uses. When the temperature plunges, that efficiency drops and the furnace takes over, at a temperature threshold we set with you.\u003c\/p\u003e\n\u003cp\u003eIn summer, a single outdoor unit replaces the window air conditioners. Cool air is distributed through the existing ducts, with no compressor noise in the bedroom, and a single thermostat controls both seasons.\u003c\/p\u003e\n\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company that has been based in Montreal for more than fifteen years. Refrigeration, ventilation and electrical work is done under RBQ licence 5645-9605-01. We serve Montreal, Laval, Longueuil, the North Shore and the South Shore. For this coil and its outdoor unit, the job includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and verifying the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, with a custom transition if needed, and sealing the connections;\u003c\/li\u003e\n\u003cli\u003ethe outdoor unit on a pad or bracket, brazed piping, a nitrogen leak test and evacuation;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and a walkthrough at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFive checks before you buy\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B requires an outdoor unit that uses the same refrigerant, installed at the same time as the coil. Do not count on keeping your old air conditioner.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified pairing, not to the coil alone.\u003c\/li\u003e\n\u003cli\u003eThe furnace width must be measured; if it does not match, a transition is planned.\u003c\/li\u003e\n\u003cli\u003eThe blower must deliver the airflow the system requires; we check it at the visit.\u003c\/li\u003e\n\u003cli\u003eIncentives depend on the complete system, not on a single part.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCanair in brief\u003c\/h3\u003e\n\u003cp\u003eCanair is a brand distributed in Quebec by Descair. Its 4CDH20 heat pump on R-454B is paired with CEB cased coils, while the MCPM and MAC coils on R-410A serve the previous generation of systems.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert incentive\u003c\/h3\u003e\n\u003cp\u003eThe paired Canair system appears on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your situation: we check the official list when we prepare the quote and put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Canair system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"CanAir","offers":[{"title":"Default Title","offer_id":68401594204452,"sku":"CEB-24MX1421","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_CANAIR_CEB_CEB_24MX1421_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795724103","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-canair-ceb-24mx1421-a-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}