{"product_id":"serpentin-devaporateur-canair-ceb-24mx1721-a-2-tonnes","title":"CANAIR CEB-24MX1721 Evaporator A-Coil | 2 Tons","description":"\u003ch2\u003eCanair CEB-24MX1721 coil: 2 tons on a 17-1\/2 in cabinet, the measurement to check first\u003c\/h2\u003e\n\u003ch3\u003eA question of inches before it is a question of BTUs\u003c\/h3\u003e\n\u003cp\u003eMany homeowners call us thinking about capacity: \"Is two tons enough?\" For this model, the real question comes first: is your furnace 17-1\/2 in wide? The \u003cstrong\u003eCanair CEB-24MX1721\u003c\/strong\u003e is a cased evaporator A-coil with an insulated cabinet, in the 2-ton size (24,000 BTU\/h), using R-454B refrigerant. Its 17-1\/2 in width fits a slightly roomier furnace cabinet than the one for the CEB-24MX1421, which measures 14-1\/2 in.\u003c\/p\u003e\n\u003cp\u003eWe install it in Montreal, Laval, Longueuil, on the North Shore and on the South Shore, mostly in bungalows and semi-detached homes where the furnace has been in place for a long time.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the coil adds to an existing furnace\u003c\/h3\u003e\n\u003cp\u003eYour furnace keeps its roles: it circulates the air, filters it and sends it into the ducts. The coil is fitted on top, in the plenum. It is of no use on its own; it receives refrigerant from an outdoor unit installed in the yard and turns that cold, or that heat, into conditioned air for every room.\u003c\/p\u003e\n\u003cp\u003eIt is often called an \"add-on\" system: you add the heat pump to the furnace instead of replacing the furnace. The investment is more reasonable, and you keep backup heating for the coldest days.\u003c\/p\u003e\n\n\u003ch3\u003eThe dimensions, as published\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ewidth: 17-1\/2 in;\u003c\/li\u003e\n\u003cli\u003eheight: 18 in;\u003c\/li\u003e\n\u003cli\u003edepth: 21 in;\u003c\/li\u003e\n\u003cli\u003etype: cased coil, CEB range;\u003c\/li\u003e\n\u003cli\u003eexpansion: TXV;\u003c\/li\u003e\n\u003cli\u003einstallation positions: multi-position.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf the furnace cabinet does not match exactly, we build an insulated transition on site. Because it is sheet-metal work done at the visit, it simply needs to be planned for in the quote.\u003c\/p\u003e\n\n\u003ch3\u003ePairing with the outdoor unit\u003c\/h3\u003e\n\u003cp\u003eCanair pairs this coil with the 4CDH20 outdoor heat pump on R-454B, which has a variable-speed compressor. Two models are published:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e4CDH2018C21\u003c\/strong\u003e, AHRI 216621486, cooling 18,000 BTU\/h, heating 19,000 BTU\/h at 47 °F, SEER2 16.1, HSPF2 9.5;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e4CDH2024C21\u003c\/strong\u003e, AHRI 216621488, cooling 24,000 BTU\/h, heating 25,000 BTU\/h at 47 °F, SEER2 16.0, HSPF2 9.5.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe AHRI numbers differ from those of the CEB-24MX1421: two coil widths, two certificates, even though the 2-ton capacity is identical. Remember this detail when you compare quotes.\u003c\/p\u003e\n\n\u003ch3\u003eHow to choose between the two outdoor units\u003c\/h3\u003e\n\u003cp\u003eThe unit rated 18,000 BTU\/h for cooling is enough for a well-insulated home or a modest-sized dwelling. The 24,000 BTU\/h unit offers more reserve for an extra floor that gets a lot of sun. We do not choose at random: a room-by-room load calculation guides the decision.\u003c\/p\u003e\n\u003cp\u003eOversized equipment is not an advantage. It shuts off before it has dehumidified the air and leaves you with a clammy feeling in July.\u003c\/p\u003e\n\n\u003ch3\u003eA concrete example: the seventies bungalow\u003c\/h3\u003e\n\u003cp\u003ePicture a South Shore bungalow with an electric furnace in the basement, a window air conditioner in every bedroom and a winter bill that causes worry. The ducts are already in place, the furnace cabinet is wide enough, and the house is compact. In a case like that, this coil makes it possible to replace the window units and ease the electric heating without touching the walls or redoing the air distribution.\u003c\/p\u003e\n\u003cp\u003eOur role is to check that this scenario holds up in your home: condition of the ducts, blower airflow, capacity of the electrical service. If anything is off, we point it out before proposing anything.\u003c\/p\u003e\n\n\u003ch3\u003eComparing with the rest of the series\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCEB-24MX1421\u003c\/strong\u003e: same capacity, 14-1\/2 in wide, same 4CDH2018C21 outdoor unit at the entry level;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCEB-36MX1421, CEB-36MX1721 and CEB-36MX2121\u003c\/strong\u003e: 3 tons, in 14-1\/2 in, 17-1\/2 in and 21 in, paired with 4CDH2030C21 units;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eCEB-60MX2121 and CEB-60MX2421\u003c\/strong\u003e: 5 tons, in 21 in and 24-1\/2 in, for large homes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAll have the same R-454B refrigerant and the same TXV expansion valve. The differences therefore come down to three points: capacity, cabinet width and outdoor unit.\u003c\/p\u003e\n\n\u003ch3\u003eWhat happens in winter, when the thermometer drops\u003c\/h3\u003e\n\u003cp\u003eThe heat pump handles most of the heating season. The colder the outdoor air, the less heat it delivers, which is why the furnace stays connected as backup. We set with you the temperature threshold below which the furnace takes over: a simple setting, which can be changed later, that balances comfort and energy use.\u003c\/p\u003e\n\u003cp\u003eIn mild weather, the heat pump delivers two to three times more heat than the electricity it uses, whereas an electric furnace simply converts each kilowatt-hour into an equal amount of heat.\u003c\/p\u003e\n\n\u003ch3\u003eEfficiency: what to really look at\u003c\/h3\u003e\n\u003cp\u003eA coil does not carry an efficiency rating on its own. The SEER2, EER2 and HSPF2 ratings belong to the complete system, identified by its AHRI number. Canair states that all CEB and 4CDH20 pairings are ENERGY STAR cold climate certified and that their heating capacity at -8.3 °C ranges from 15,200 to 37,800 BTU\/h depending on the pairing.\u003c\/p\u003e\n\n\u003ch3\u003eThe job, step by step\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company based in Montreal for more than fifteen years, and our work is done under RBQ licence 5645-9605-01. Here is the usual order:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, sealing the joints and adding a transition if needed;\u003c\/li\u003e\n\u003cli\u003einstalling the outdoor unit, brazed piping, nitrogen leak test, evacuation;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and an explanation of how everything works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eRoutine maintenance, no surprises\u003c\/h3\u003e\n\u003cp\u003eA clean filter, a clear condensate drain and an outdoor unit kept free of leaves and snow: that is the essential. We explain each step at commissioning and remain available if a question comes up. A well-maintained coil keeps its performance from one season to the next.\u003c\/p\u003e\n\n\u003ch3\u003eManufacturer warranty\u003c\/h3\u003e\n\u003cp\u003eThe Canair list states, for residential use, 10 years on the compressor and 10 years on parts; for commercial use, 5 years and 1 year. A 10-year limited labour warranty can be added as an option, according to the manufacturer's brochure.\u003c\/p\u003e\n\n\u003ch3\u003eBefore you sign\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-454B requires an outdoor unit that uses the same refrigerant, installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply to the certified pairing.\u003c\/li\u003e\n\u003cli\u003eThe furnace must have the right width and blower; we confirm this at the visit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAbout the brand\u003c\/h3\u003e\n\u003cp\u003eCanair is distributed in Quebec by Descair. Its 4CDH20 central heat pump on R-454B is paired with CEB cased coils; the MCPM and MAC coils, on R-410A, are intended for the previous generation of systems.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert incentive\u003c\/h3\u003e\n\u003cp\u003eThe paired Canair system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We consult the official list when we prepare the quote and put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Canair system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"CanAir","offers":[{"title":"Default Title","offer_id":68401594237220,"sku":"CEB-24MX1721","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_CANAIR_CEB_CEB_24MX1721_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795724122","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-canair-ceb-24mx1721-a-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}