{"product_id":"serpentin-devaporateur-canair-mcpm3036anod-a-3-tonnes","title":"CANAIR MCPM3036ANOD Evaporator A-Coil | 3 Tons","description":"\u003ch2\u003eMCPM3036ANOD: 3 tons in a 14-1\/2 in casing, in question-and-answer form\u003c\/h2\u003e\n\u003cp\u003eWe hear the same questions, from Longueuil to Laval, when a homeowner is considering a 3-ton coil. Rather than run through a spec sheet, here is the \u003cstrong\u003eCanair MCPM3036ANOD evaporator coil\u003c\/strong\u003e presented as a conversation at the kitchen table: what it is, what it does, what to check.\u003c\/p\u003e\n\n\u003ch3\u003eWhat exactly is the MCPM3036ANOD?\u003c\/h3\u003e\n\u003cp\u003eIt is a cased A-coil from the Canair MCPM range, running on \u003cstrong\u003eR-410A\u003c\/strong\u003e. Its nominal capacity is 3 tons (36,000 BTU\/h) and its casing is 14-1\/2 in wide. It sits on a furnace or blower cabinet and connects to a Canair outdoor unit of the same capacity.\u003c\/p\u003e\n\n\u003ch3\u003eIn what kind of house do we see it most often?\u003c\/h3\u003e\n\u003cp\u003eIn bungalows and cottages across Greater Montreal: a furnace in the basement, ducts that reach every room, and an old central air conditioner or window units in summer. The 3-ton size covers a good share of these houses. We always validate the choice with a load calculation, because two houses of the same floor area do not lose the same amount of heat.\u003c\/p\u003e\n\n\u003ch3\u003eWhy a 14-1\/2 in casing?\u003c\/h3\u003e\n\u003cp\u003eBecause many furnaces have this narrow footprint. A 3-ton coil of this width is useful when space is tight: a mechanical closet, a basement corner, a passage between two beams. Its dimensions (W × H × D) are 14-1\/2 × 20 × 21 in.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if my furnace is wider?\u003c\/h3\u003e\n\u003cp\u003eThen look at the other two 3-ton models: the \u003cstrong\u003eMCPM3036BNOD\u003c\/strong\u003e is 17-1\/2 in wide and the \u003cstrong\u003eMCPM3036CNOD\u003c\/strong\u003e is 21 in wide. Same capacity, same R-410A, same A shape, same factory piston. The only published difference is the width. A casing too narrow for the furnace needs a transition; so does one that is too wide. The right model is the one that comes closest.\u003c\/p\u003e\n\u003cp\u003eFor those unsure about capacity, the \u003cstrong\u003eMCPM2430ANOF\u003c\/strong\u003e offers the same 14-1\/2 in width in 2.5 tons. The 4-ton models start at 17-1\/2 in.\u003c\/p\u003e\n\n\u003ch3\u003eHow does it cool?\u003c\/h3\u003e\n\u003cp\u003eCold refrigerant flows through the coil's tubes while the furnace blower pushes the house air through. The air gives up its heat, is dehumidified, then returns to the rooms. The water collected in the pan leaves through the 3\/4 in NPT female drain (primary and secondary). The liquid connection is 3\/8 in.\u003c\/p\u003e\n\n\u003ch3\u003eAnd how does it heat?\u003c\/h3\u003e\n\u003cp\u003eOnly if the outdoor unit is a heat pump: the cycle then reverses, and the air sent through the ducts is warmed by the refrigerant. The furnace stays there for the coldest days, below a threshold we set with you. With a central air conditioner, the coil only provides cooling.\u003c\/p\u003e\n\n\u003ch3\u003eWhat metering device does it use?\u003c\/h3\u003e\n\u003cp\u003eA factory-installed piston (fixed orifice), with an optional TXV kit. The piston meters the refrigerant with no moving parts; the TXV valve adjusts further to changes in load. We explain the difference and recommend one based on your outdoor unit.\u003c\/p\u003e\n\n\u003ch3\u003eIs it compatible with an outdoor unit already in place?\u003c\/h3\u003e\n\u003cp\u003eRarely as is. The coil runs on R-410A and is matched with the outdoor unit specified by the manufacturer. For SEER2, EER2 and HSPF2 ratings, you need the certified system, with its AHRI number. Canair does not publish any AHRI or ENERGY STAR match for the MCPM NOD\/NOF: we validate it with the distributor before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eWhere does the brand come from?\u003c\/h3\u003e\n\u003cp\u003eCanair is distributed in Quebec by Descair. Its 4CDH20 central heat pump, which uses R-454B, is matched with cased CEB coils; the MCPM and MAC coils on R-410A serve the previous generation of systems.\u003c\/p\u003e\n\n\u003ch3\u003eWhat does our installation include?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFurnace measurements, blower check and electrical panel check.\u003c\/li\u003e\n\u003cli\u003eCoil installed in the plenum, transition built on site if needed, duct connections sealed.\u003c\/li\u003e\n\u003cli\u003eOutdoor unit on a pad or bracket, brazed piping, nitrogen test, vacuum.\u003c\/li\u003e\n\u003cli\u003eDrain and thermostat connection.\u003c\/li\u003e\n\u003cli\u003eCommissioning, airflow adjustment, demonstration at the house.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe AirGreen team, a family-owned Montreal heating and cooling company for more than fifteen years, works under RBQ licence 5645-9605-01.\u003c\/p\u003e\n\n\u003ch3\u003eHow long does the job take?\u003c\/h3\u003e\n\u003cp\u003eIn a house where the furnace is accessible, installing the coil and the outdoor unit normally takes one careful day of work, sometimes a bit more if the piping has to pass through a difficult foundation wall. We tell you at the visit if we expect extra work, for example a plenum transition, a new pad or an upgrade to the electrical circuit.\u003c\/p\u003e\n\n\u003ch3\u003eWhat do I do with the furnace in winter?\u003c\/h3\u003e\n\u003cp\u003eNothing special: it stays connected and ready. When the outdoor unit is a heat pump, it does most of the work, and the thermostat lets the furnace take over only below the threshold set with you. You can adjust that threshold later if your bill or your comfort calls for it.\u003c\/p\u003e\n\n\u003ch3\u003eIs maintenance needed?\u003c\/h3\u003e\n\u003cp\u003eA clean filter, a clear condensate pan and an annual look at the connections: that is the essentials. The coil itself has no moving parts. We offer a check-up visit at the start of the season to confirm that the drain, the thermostat and the airflow work as they did on the first day.\u003c\/p\u003e\n\n\u003ch3\u003eMy basement is damp, is that an obstacle?\u003c\/h3\u003e\n\u003cp\u003eOn the contrary: as it cools the air, the coil also removes some of its moisture. This does not replace a dehumidifier in a basement that floods, but the air in the house ends up drier in summer. We simply make sure the condensate is drained to a safe place.\u003c\/p\u003e\n\n\u003ch3\u003eWhy not choose \"a bit bigger, just in case\"?\u003c\/h3\u003e\n\u003cp\u003eBecause an oversized system shuts off before it has dehumidified the air: the house feels cool but clammy, and the unit starts more often than it should. It is better to have an honest calculation and a coil whose capacity fits the house. If the calculation falls between two sizes, we lay out both options with their advantages.\u003c\/p\u003e\n\n\u003ch3\u003eWhat might you be overlooking?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe blower must deliver the airflow of the 3-ton system.\u003c\/li\u003e\n\u003cli\u003ePublished ratings apply only to the certified match.\u003c\/li\u003e\n\u003cli\u003eThe manufacturer's warranty is not published for this model; we confirm it in writing with the quote.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAnd incentives?\u003c\/h3\u003e\n\u003cp\u003eThey depend on the complete system, not on the coil alone. We check the official Hydro-Québec list, including LogisVert, based on the installation date, and tell you what applies in Montreal, on the North Shore or on the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eWhere to start?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Canair system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"CanAir","offers":[{"title":"Default Title","offer_id":68401595351332,"sku":"MCPM3036ANOD","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_CANAIR_MCPM_MCPM3036ANOD_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795724122","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-canair-mcpm3036anod-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}