{"product_id":"serpentin-devaporateur-canair-mcpm3036bnod-a-3-tonnes","title":"CANAIR MCPM3036BNOD Evaporator A-Coil | 3 Tons","description":"\u003ch2\u003eHumidity, comfort and condensate: the 3-ton MCPM3036BNOD (17-1\/2 in)\u003c\/h2\u003e\n\u003cp\u003eA central air conditioner does more than lower the temperature. In a South Shore or Laval home in the middle of a sticky summer, what really changes your life is the air becoming dry. The \u003cstrong\u003eCanair MCPM3036BNOD evaporator coil\u003c\/strong\u003e is the part that does this work: a 3-ton (36,000 BTU\/h) A-coil with a 17-1\/2 in casing that runs on \u003cstrong\u003eR-410A\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eThe coil, a cold surface that dries the air\u003c\/h3\u003e\n\u003cp\u003eWhen the warm, humid air of the house brushes against the cold fins, the water vapour condenses, like on a glass of lemonade. This liquid runs into the pan, then into the drain. The air returning to the rooms is therefore cooler and drier. The more steadily the coil runs, the more moisture it removes: that is why a well-chosen size is better than one that is too generous.\u003c\/p\u003e\n\n\u003ch3\u003eWhere does it go, and how?\u003c\/h3\u003e\n\u003cp\u003eIn the plenum of a furnace or blower cabinet. The insulated casing holds the coil, the pan and the connections. Its dimensions (W × H × D) are 17-1\/2 × 20 × 21 in, and the manufacturer lists four positions: upflow, horizontal right, downflow, horizontal left. A homeowner whose furnace hangs in an attic space can therefore orient it as needed.\u003c\/p\u003e\n\n\u003ch3\u003eThe water's path, from start to finish\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCondensate forms on the coil and drops into the built-in pan.\u003c\/li\u003e\n\u003cli\u003eThe 3\/4 in NPT female primary drain carries it to a floor drain or a condensate pump.\u003c\/li\u003e\n\u003cli\u003eA secondary drain of the same diameter acts as a safeguard in case of a blockage.\u003c\/li\u003e\n\u003cli\u003eWe set even slopes and add a trap when the floor drain calls for it.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn a finished basement, we also show you how to check the drainage with a small glass of water in the spring.\u003c\/p\u003e\n\n\u003ch3\u003eConnections and metering device\u003c\/h3\u003e\n\u003cp\u003eThe liquid line connection is 3\/8 in. The refrigerant flow is set by a factory-installed piston (fixed orifice); a TXV kit is available as an option. The piston suits everyday use well; the TXV valve adjusts further when the load varies a lot over the course of the day. We decide with you based on the outdoor unit and the house.\u003c\/p\u003e\n\n\u003ch3\u003e3 tons: are they the right proportions for your house?\u003c\/h3\u003e\n\u003cp\u003eThis size suits many bungalows and cottages in Greater Montreal, but only a load calculation confirms it. We measure the windows, assess the insulation of the walls and roof, note the afternoon sun exposure and count the rooms served by the ducts. If the result calls for 2.5 tons or 4 tons, we tell you.\u003c\/p\u003e\n\n\u003ch3\u003eComparison with the rest of the series\u003c\/h3\u003e\n\u003cp\u003eAt the same 3-ton capacity, the series offers three widths:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eMCPM3036ANOD\u003c\/strong\u003e: 14-1\/2 in, for a narrow furnace;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMCPM3036BNOD\u003c\/strong\u003e (this one): 17-1\/2 in;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMCPM3036CNOD\u003c\/strong\u003e: 21 in, for a wide furnace.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe 17-1\/2 in width is also found on the MCPM2430BNOF (2.5 tons) and the MCPM4248BNOF (4 tons). All models in the series are cased A-coils, use R-410A and have a factory piston.\u003c\/p\u003e\n\n\u003ch3\u003eA system, not a loose part\u003c\/h3\u003e\n\u003cp\u003eThe coil has no efficiency rating of its own. SEER2, EER2 and HSPF2 belong to the complete match, identified by an AHRI number. Canair does not publish any AHRI or ENERGY STAR match for the MCPM NOD\/NOF coils; we validate it with the distributor based on the outdoor unit, before ordering anything.\u003c\/p\u003e\n\u003cp\u003eThe brand is distributed in Quebec by Descair. The 4CDH20 central heat pump, on R-454B, is matched with cased CEB coils; the MCPM and MAC models on R-410A are intended for previous-generation systems.\u003c\/p\u003e\n\n\u003ch3\u003eThe job: order of operations\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVisit: furnace measurements, blower, electrical panel.\u003c\/li\u003e\n\u003cli\u003eCoil installed in the plenum, with an insulated transition if needed, and duct connections sealed.\u003c\/li\u003e\n\u003cli\u003eOutdoor unit on a pad or bracket; brazed piping, nitrogen leak test, vacuum.\u003c\/li\u003e\n\u003cli\u003eCondensate drain and thermostat.\u003c\/li\u003e\n\u003cli\u003eCommissioning, airflow adjustment, explanations.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years; the work is done under RBQ licence 5645-9605-01. We serve Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eAfter installation: three habits to keep the air dry\u003c\/h3\u003e\n\u003cp\u003eA clean coil dries better. Replace the furnace filter at regular intervals, especially during the warm season, because a clogged filter reduces airflow and makes the fins frost over. Also keep the return grilles clear: a piece of furniture in front of one chokes the system. Finally, watch the drain on a humid day: a thin trickle of water running out is a good sign.\u003c\/p\u003e\n\u003cp\u003eThese habits take less than ten minutes a month, and they extend the life of the coil as well as the blower. We go over them when we hand over the system, with a short written reminder for each member of the family.\u003c\/p\u003e\n\n\u003ch3\u003eWhat this model does not do\u003c\/h3\u003e\n\u003cp\u003eIt does not replace a dehumidifier in a basement where water seeps in, and it does not fix poorly insulated ducts in a scorching attic. If we see such defects at the visit, we point them out: a good coil in a deficient air network gives mediocre comfort. Sometimes a few simple duct fixes do more for your summer than a change of capacity.\u003c\/p\u003e\n\n\u003ch3\u003eThree important checks\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-410A is matched with an outdoor unit that uses the same refrigerant.\u003c\/li\u003e\n\u003cli\u003eThe furnace must have the right width, or a transition will be built.\u003c\/li\u003e\n\u003cli\u003eThe blower must be able to deliver the system's airflow; otherwise, comfort suffers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe manufacturer's warranty is not published for this model. We confirm it in writing with the quote.\u003c\/p\u003e\n\n\u003ch3\u003eWith a heat pump, winter too\u003c\/h3\u003e\n\u003cp\u003eIf the outdoor unit is a heat pump, the cycle reverses in the cold season and the same coil warms the air passing through your ducts. The furnace keeps its blower and serves as backup heat below the outdoor temperature threshold we set with you. With a central air conditioner, the coil stays dedicated to cooling.\u003c\/p\u003e\n\n\u003ch3\u003eQuestions customers often ask\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan the coil be used on its own?\u003c\/strong\u003e No: it is part of a system with an outdoor unit using the same refrigerant, installed along with it.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo I have to change my ducts?\u003c\/strong\u003e Generally not. We check their condition and airtightness, then seal the connections at the plenum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhen can I have the system installed?\u003c\/strong\u003e We set a date after the visit and the confirmation of the match, depending on equipment availability.\u003c\/p\u003e\n\n\u003ch3\u003eHydro-Québec incentives\u003c\/h3\u003e\n\u003cp\u003eEligibility, notably for the LogisVert program, depends on the matched system and not on the coil alone. We check the official list based on the installation date and tell you what applies before you sign.\u003c\/p\u003e\n\n\u003ch3\u003eNext step\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Canair system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"CanAir","offers":[{"title":"Default Title","offer_id":68401596268836,"sku":"MCPM3036BNOD","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_CANAIR_MCPM_MCPM3036BNOD_00_3_TONNES_36000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795724129","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-canair-mcpm3036bnod-a-3-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}