{"product_id":"serpentin-devaporateur-canair-mcpm4248dnof-a-4-tonnes","title":"CANAIR MCPM4248DNOF Evaporator A-Coil | 4 Tons","description":"\u003ch2\u003eMCPM4248DNOF: the 24-1\/2 in casing for large furnaces, in 4 tons\u003c\/h2\u003e\n\u003cp\u003eThe letter D in the Canair model number signals the widest footprint in the 4-ton family: 24-1\/2 in. The \u003cstrong\u003eMCPM4248DNOF evaporator coil\u003c\/strong\u003e is meant for large furnaces and blower cabinets designed for high volumes of air. It is a cased A-coil, rated at a nominal 48,000 BTU\/h, running on \u003cstrong\u003eR-410A\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch3\u003eA big house, a big housing\u003c\/h3\u003e\n\u003cp\u003eIn Laval, on the North Shore or in Longueuil, you find large two-storey houses with finished basements and sometimes an addition built twenty years ago. Their furnace is often wide, because it has to push a lot of air. A 24-1\/2 in casing avoids choking that air at the coil's inlet. The dimensions (W × H × D) are 24-1\/2 × 30 × 21 in.\u003c\/p\u003e\n\n\u003ch3\u003eIf the furnace is narrower than 24-1\/2 in\u003c\/h3\u003e\n\u003cp\u003eThe coil can be connected to a narrower furnace with a transition built and insulated on site. But a large transition is not free: it costs labour and static pressure. In that case, the MCPM4248CNOF (21 in) or the MCPM4248BNOF (17-1\/2 in) may be a better fit. It is the actual footprint of your furnace that decides, not capacity alone.\u003c\/p\u003e\n\n\u003ch3\u003eSide-by-side look at the three 4-ton models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eMCPM4248BNOF\u003c\/strong\u003e: 17-1\/2 in, for a narrow furnace;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMCPM4248CNOF\u003c\/strong\u003e: 21 in, intermediate width;\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eMCPM4248DNOF\u003c\/strong\u003e (this one): 24-1\/2 in, for a wide furnace.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eFor the same 24-1\/2 in width, the MCPM4860DNOF offers 5 tons. The other published data are identical: A shape, casing, R-410A, factory piston, optional TXV kit.\u003c\/p\u003e\n\n\u003ch3\u003eWhy large air volumes change things\u003c\/h3\u003e\n\u003cp\u003eA 4-ton coil moves a lot of air. The wider the passage, the lower the speed through the fins, which reduces noise and helps the coil work under good conditions. But the air still needs a clear path: ducts that are large enough, a return that is open enough and a clean filter. We check these three points at the same time as the blower.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical details at a glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003etype: cased evaporator coil, A shape;\u003c\/li\u003e\n\u003cli\u003enominal capacity: 4 tons (48,000 BTU\/h);\u003c\/li\u003e\n\u003cli\u003eliquid connection: 3\/8 in;\u003c\/li\u003e\n\u003cli\u003econdensate drain: 3\/4 in NPT female, primary and secondary;\u003c\/li\u003e\n\u003cli\u003epositions: upflow, horizontal right, downflow, horizontal left;\u003c\/li\u003e\n\u003cli\u003emetering: factory piston (fixed orifice), optional TXV kit;\u003c\/li\u003e\n\u003cli\u003ewarranty: not published for this model, confirmed in writing with the quote.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWhich outdoor unit goes with it?\u003c\/h3\u003e\n\u003cp\u003eA Canair unit of the same capacity and the same refrigerant. SEER2, EER2 and HSPF2 ratings belong to the certified system, linked by an AHRI number. For the MCPM NOD\/NOF coils, Canair does not publish any AHRI or ENERGY STAR match: we therefore validate the match with the distributor, Descair, before ordering.\u003c\/p\u003e\n\u003cp\u003eThe Canair 4CDH20 central heat pump on R-454B is paired with cased CEB coils; the MCPM4248DNOF, for its part, belongs to the previous-generation R-410A family.\u003c\/p\u003e\n\n\u003ch3\u003eHow we work on a big job\u003c\/h3\u003e\n\u003cp\u003eA large house calls for method. We walk through each floor first to note the registers and returns. On installation day, we protect the floor, cut the power and prepare the plenum. The coil installation is followed by the outdoor unit setup, the brazed piping, the nitrogen test and the vacuum. We finish with the drain, the thermostat, commissioning and a room-by-room airflow adjustment.\u003c\/p\u003e\n\u003cp\u003eAirGreen is a family-owned heating and cooling company based in Montreal for more than fifteen years, under RBQ licence 5645-9605-01. We serve Montreal, Laval, Longueuil, the North Shore and the South Shore.\u003c\/p\u003e\n\n\u003ch3\u003eHeating with the same installation\u003c\/h3\u003e\n\u003cp\u003eMatched with a heat pump, the coil also heats the house in winter, through the existing ducts. The furnace takes over only below the outdoor temperature threshold set with you. In a large house, this sharing of roles can lighten the furnace's load for a good part of the cold season.\u003c\/p\u003e\n\n\u003ch3\u003eTo check before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eR-410A requires an outdoor unit with the same refrigerant.\u003c\/li\u003e\n\u003cli\u003eThe furnace must have the 24-1\/2 in width, or the transition will be built.\u003c\/li\u003e\n\u003cli\u003eThe blower must reach the airflow of the 4-ton system.\u003c\/li\u003e\n\u003cli\u003eThe electrical service must accommodate the outdoor unit's circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eNoise and acoustic comfort\u003c\/h3\u003e\n\u003cp\u003eA large casing and a large, well-directed volume of air often give a quieter system: the air moves slowly, with no whistling at the registers. Conversely, an undersized duct behind a 4-ton coil produces an audible, uncomfortable rush of air. We listen to the system at commissioning, measure the airflow room by room and adjust the registers as needed.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing the outdoor unit's location\u003c\/h3\u003e\n\u003cp\u003eThe outdoor unit goes on a pad or bracket, at a good distance from bedroom windows, away from places where snow piles up and without blocking passage. In Montreal neighbourhoods where yards are narrow, we look for the spot that respects your neighbours and leaves access for maintenance. On the North Shore and South Shore, where lots are larger, we favour proximity to the plenum to shorten the piping.\u003c\/p\u003e\n\n\u003ch3\u003eCommon questions about this model\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eCan this coil heat?\u003c\/strong\u003e Yes, with a heat pump; with a central air conditioner, it only cools.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCan I keep my current air conditioner?\u003c\/strong\u003e Generally not: you need an outdoor unit with the same refrigerant, installed along with the coil.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs the furnace still useful?\u003c\/strong\u003e Yes, it keeps its blower and serves as backup during the coldest weather.\u003c\/p\u003e\n\n\u003ch3\u003eWhat you keep from your current installation\u003c\/h3\u003e\n\u003cp\u003eThe furnace, its blower, its filters and your ducts stay in place. Only the coil, the outdoor unit and the refrigerant piping are new. In a large house, this avoids opening finished walls or ceilings, and the job is limited to the basement, the plenum and the yard. We protect surfaces and clean up behind us.\u003c\/p\u003e\n\u003cp\u003eIf your furnace is nearing the end of its life, let us talk about it at the visit: it may be sensible to plan its replacement at the same time, so that the two units are designed together.\u003c\/p\u003e\n\n\u003ch3\u003eGovernment assistance\u003c\/h3\u003e\n\u003cp\u003eHydro-Québec incentives, including LogisVert, are assessed on the complete system and not on the coil. We confirm eligibility based on the installation date, using the official list, and tell you what applies.\u003c\/p\u003e\n\n\u003ch3\u003eA clear quote\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eRequest your free on-site estimate: we measure the furnace, check the electrical service and give you a written quote for the complete Canair system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"CanAir","offers":[{"title":"Default Title","offer_id":68401592926500,"sku":"MCPM4248DNOF","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_CANAIR_MCPM_MCPM4248DNOF_00_4_TONNES_48000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795724105","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-canair-mcpm4248dnof-a-4-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}