{"product_id":"serpentin-devaporateur-comfortmaker-eaa5x24m14a-a-2-tonnes","title":"COMFORTMAKER EAA5X24M14A Evaporator A-Coil | 2 Tons","description":"\u003ch2\u003eEAA5X24M14A: the 2-ton Comfortmaker coil for narrow furnaces\u003c\/h2\u003e\n\u003cp\u003eSome furnaces are slim: the ones in row houses, duplexes and small plex units where the appliance was squeezed into a corner of the mechanical room. The \u003cstrong\u003eComfortmaker EAA5X24M14A\u003c\/strong\u003e was designed for that kind of footprint. At 13-1\/8 in wide, it is the narrower of the two 2-ton coils in the EAA5X range. It is sold uncased, runs on R-454B refrigerant and connects to a Comfortmaker outdoor unit to form a complete central system.\u003c\/p\u003e\n\u003cp\u003eAirGreen installs it in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, on the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and on the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. Here is what you need to know to decide whether this model is the right one for your home.\u003c\/p\u003e\n\n\u003ch3\u003eWhat an evaporator coil does in your plenum\u003c\/h3\u003e\n\u003cp\u003eThe coil is a heat exchanger mounted in the plenum, just above the furnace. The furnace fan pushes the air from your home through its cold tubes. The refrigerant, which evaporates inside, absorbs heat from that air; moisture condenses on the surfaces and runs down to the pan, then out through the drain.\u003c\/p\u003e\n\u003cp\u003eOn its own, it does nothing: it needs an outdoor unit, piped to it, that compresses the refrigerant and releases the heat outside. If the outdoor unit is a heat pump, the cycle can reverse in winter and the same coil is then used for heating.\u003c\/p\u003e\n\n\u003ch3\u003eWhy width matters as much as tons\u003c\/h3\u003e\n\u003cp\u003eWhen people compare coils, they look at capacity first. For a furnace installation, width is just as decisive. The coil has to fit in the plenum or in a cabinet of the same size; otherwise the air bypasses the heat exchanger and capacity drops.\u003c\/p\u003e\n\u003cp\u003eThe EAA5X24M14A measures 13-1\/8 in wide by 19-7\/8 in high. If your furnace has a different width, we measure on site and, if needed, build an insulated transition. This is routine sheet-metal work, and it is done the same day as the installation.\u003c\/p\u003e\n\n\u003ch3\u003eAn A shape, two permitted positions\u003c\/h3\u003e\n\u003cp\u003eThis is an A-type coil: two sloped faces that meet at the top. Air enters from below and passes through each face. The manufacturer allows two orientations: upflow or downflow vertical. Horizontal installation is prohibited, and we never propose it for this model. If your furnace lies on its side in a crawl space, this model is not the right one.\u003c\/p\u003e\n\u003cp\u003eThe metering device is a TXV: a thermostatic expansion valve that doses the refrigerant according to the coil's actual load.\u003c\/p\u003e\n\n\u003ch3\u003eThe certified system, step by step\u003c\/h3\u003e\n\u003cp\u003ePerformance ratings do not belong to the coil alone. They describe a trio: this coil, a specific outdoor unit and an AHRI number that links them. For the EAA5X24M14A, three outdoor units are published.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eB5H3V24*K*AAA\u003c\/strong\u003e (AHRI 218405915): 21,600 BTU\/h cooling, 26,600 BTU\/h heating at 47 °F, SEER2 19.0, HSPF2 9.5. On paper, this is the best-performing match of the three.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eC5H0V24*K*AAA\u003c\/strong\u003e (AHRI 215666934): 22,800 BTU\/h cooling, 24,000 BTU\/h heating at 47 °F, SEER2 17.0, HSPF2 9.0.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eC5H8T24*K*AAA\u003c\/strong\u003e (AHRI 216364538): 22,200 BTU\/h cooling, 25,000 BTU\/h heating at 47 °F, SEER2 15.5, HSPF2 8.0.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eComfortmaker also publishes ENERGY STAR matches under the \"EA*5X\" family, which groups the EAM5X and EAA5X, with the Q5H9V and N5H9V heat pumps, the SoftSound B5H0V, B5H3V and C5H0V, and the Mainline C5H8T. All of them run on R-454B.\u003c\/p\u003e\n\n\u003ch3\u003eWhat you gain by switching to a heat pump\u003c\/h3\u003e\n\u003cp\u003eIf your home is heated with an electric furnace, every kilowatt-hour becomes exactly one kilowatt-hour of heat. A heat pump instead moves heat from outside to inside; in mild weather, it delivers more heat than the electricity it uses. The furnace keeps its role: it takes over when the outdoor temperature falls below the threshold we set with you.\u003c\/p\u003e\n\u003cp\u003eIn summer, the same system replaces window units and distributes cool air to every room through your existing ducts. A single thermostat controls both seasons.\u003c\/p\u003e\n\n\u003ch3\u003eChoosing between the 24M14A and its neighbours\u003c\/h3\u003e\n\u003cp\u003eWithin the series, the choice comes down to three questions: capacity, width and the planned outdoor unit.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X24M17A\u003c\/strong\u003e: same 2-ton capacity, but 16-7\/16 in wide. It suits wider furnaces. Its match with the B5H3V24*K*AAA is published under a different AHRI number and with a different SEER2; we give you both sheets.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X30M14A\u003c\/strong\u003e: same 13-1\/8 in width, but 2.5 tons, with the Q5H9V24*K*AAA and N5H9V24*K*AAA units.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eThe 3-ton and larger sizes\u003c\/strong\u003e (36M17A, 37M17A, 42M21A, 48M21A, 60M24A, 61M21A) are meant for larger homes and wider furnaces.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIn other words, if the furnace is slim and the home is small, this 24M14A is the natural choice. If the furnace is wide, we look at the M17A.\u003c\/p\u003e\n\n\u003ch3\u003eEAA5X24M14A specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Comfortmaker, EAA5X range.\u003c\/li\u003e\n\u003cli\u003eType: uncased evaporator coil.\u003c\/li\u003e\n\u003cli\u003eNominal size: 2 tons, or 24,000 BTU\/h.\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B.\u003c\/li\u003e\n\u003cli\u003eDimensions W × H × D: 13-1\/8 × 19-7\/8 in.\u003c\/li\u003e\n\u003cli\u003eMetering device: TXV.\u003c\/li\u003e\n\u003cli\u003eCondensate drain: 3\/4 in FPT primary and secondary connections.\u003c\/li\u003e\n\u003cli\u003eLeak detection: generation 2, 5 V refrigerant sensor, factory-installed in the coil. It is not compatible with generation 1 dissipation boards.\u003c\/li\u003e\n\u003cli\u003eWarranty: 10-year limited parts warranty if registered within 90 days of installation; 5 years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe leak sensor deserves an explanation. The manufacturer builds this sensor into the coil, and it works with a generation 2 dissipation board. Installation manual IM-EAA5X-05 states that the furnace must be compatible with this generation. We verify this before ordering.\u003c\/p\u003e\n\n\u003ch3\u003eWhat our installation includes\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company, based in Montreal for more than fifteen years. Refrigeration, ventilation and electrical work is carried out under RBQ licence 5645-9605-01. For this system, the work follows this order:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003emeasuring the furnace, checking the blower and the electrical panel;\u003c\/li\u003e\n\u003cli\u003einstalling the coil in the plenum, a custom transition if needed, and sealing the duct joints;\u003c\/li\u003e\n\u003cli\u003esetting the outdoor unit on a pad or bracket, brazing the piping, nitrogen leak test and vacuum;\u003c\/li\u003e\n\u003cli\u003econnecting the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ecommissioning, airflow adjustment and a walk-through at your home.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch3\u003eBefore ordering, check these three points\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil's refrigerant is R-454B: the outdoor unit must use the same refrigerant and be installed at the same time.\u003c\/li\u003e\n\u003cli\u003eThe published ratings apply only to the certified match specified by Comfortmaker.\u003c\/li\u003e\n\u003cli\u003eThe furnace width and blower capacity must be suitable; we confirm this at the visit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eAbout the brand\u003c\/h3\u003e\n\u003cp\u003eComfortmaker belongs to International Comfort Products (ICP), a Carrier subsidiary. Its R-454B coils go with the brand's central air conditioners and heat pumps, installed on a furnace or blower cabinet.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert incentive\u003c\/h3\u003e\n\u003cp\u003eThe matched system appears on Hydro-Québec's list of eligible heat pumps. The amount depends on the installation date and your situation. We check the official list when we prepare your quote and put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eThe on-site estimate is free: we measure the furnace, look at the electrical service and give you a written quote for the complete Comfortmaker system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e lets you spread the cost of the project.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402717819172,"sku":"EAA5X24M14A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EAA5X_EAA5X24M14A_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765770","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-eaa5x24m14a-a-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}