{"product_id":"serpentin-devaporateur-comfortmaker-eaa5x24m17a-a-2-tonnes","title":"COMFORTMAKER EAA5X24M17A Evaporator A-Coil | 2 Tons","description":"\u003ch2\u003eComfortmaker EAA5X24M17A: 2 tons of capacity in a 16-7\/16 in size\u003c\/h2\u003e\n\u003cp\u003eYou have a small home, but your furnace is not the slim model. It is wider than a row-house unit, and so is the plenum above it. That is exactly the situation the \u003cstrong\u003eEAA5X24M17A\u003c\/strong\u003e is built for: a 2-ton Comfortmaker evaporator coil, running on R-454B refrigerant, whose 16-7\/16 in width fits a roomier plenum.\u003c\/p\u003e\n\u003cp\u003eWe install it for customers in \u003cstrong\u003eMontreal\u003c\/strong\u003e, \u003cstrong\u003eLaval\u003c\/strong\u003e, \u003cstrong\u003eLongueuil\u003c\/strong\u003e, the \u003cstrong\u003eNorth Shore\u003c\/strong\u003e and the \u003cstrong\u003eSouth Shore\u003c\/strong\u003e. This page explains who it is for, what to check and how it compares with the rest of the series.\u003c\/p\u003e\n\n\u003ch3\u003eThe three published matches at a glance\u003c\/h3\u003e\n\u003cp\u003eA coil has no rating of its own: it is the complete systems that receive one. Comfortmaker publishes three matches for this model, each with its own AHRI number.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eWith the \u003cstrong\u003eB5H3V24*K*AAA\u003c\/strong\u003e heat pump, the AHRI number is 218406027. Capacity is 22,000 BTU\/h cooling and 26,200 BTU\/h heating at 47 °F, SEER2 20.0, HSPF2 9.5.\u003c\/li\u003e\n\u003cli\u003eWith the \u003cstrong\u003eC5H0V24*K*AAA\u003c\/strong\u003e, AHRI 215667135: 22,800 BTU\/h cooling, 24,000 BTU\/h heating at 47 °F, SEER2 16.5, HSPF2 9.0.\u003c\/li\u003e\n\u003cli\u003eWith the \u003cstrong\u003eC5H8T24*K*AAA\u003c\/strong\u003e, AHRI 216364602: 22,600 BTU\/h cooling, 24,600 BTU\/h heating at 47 °F, SEER2 17.0, HSPF2 8.1.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese values do not carry over from one coil to another. Even an identical outdoor unit receives a different AHRI number depending on the coil it is matched with. When you compare two quotes, ask for this number: it shows that the trio was tested together.\u003c\/p\u003e\n\n\u003ch3\u003eWhy 16-7\/16 in changes the installation\u003c\/h3\u003e\n\u003cp\u003eA wider coil offers a more open air section. In a plenum of the same width, the air passes straight through without detours and crosses both faces of the coil. In a narrower plenum, we have to reduce or redirect the passage, and that is where the gains of a well-chosen match are lost.\u003c\/p\u003e\n\u003cp\u003eIf your furnace does not match this width, the answer is not to force the installation. We build an insulated sheet-metal transition, cut to the size of the existing plenum. The coil then keeps its full surface, and the sealing of the connections is redone properly.\u003c\/p\u003e\n\n\u003ch3\u003eThe A-coil and its orientation limits\u003c\/h3\u003e\n\u003cp\u003eThe EAA5X24M17A is an uncased A-coil, 19-7\/8 in high. It is installed in a vertical position, upflow or downflow. The manufacturer prohibits horizontal installation. For a furnace lying on its side under a low floor, you have to consider another product family; we tell you so at the first visit.\u003c\/p\u003e\n\u003cp\u003eRefrigerant metering is handled by a TXV. It adjusts to the thermal load of the moment, which keeps the coil within its operating range when the return air is warmer or cooler.\u003c\/p\u003e\n\n\u003ch3\u003eWhat exactly is a 2-ton home?\u003c\/h3\u003e\n\u003cp\u003eA 2-ton size, or 24,000 BTU\/h, suits a compact, well-insulated home: a modest bungalow, a semi-detached house, the ground floor of a plex. The classic trap is choosing bigger \"to be safe.\" An oversized system shuts off quickly, cools the air without time to dry it, and the home stays clammy in muggy weather.\u003c\/p\u003e\n\u003cp\u003eBefore we propose this size, we assess the actual load: windows, attic insulation, number of rooms served. If the result calls for more capacity, we move up to the next size without hesitation.\u003c\/p\u003e\n\n\u003ch3\u003eWhat the heat pump adds in winter\u003c\/h3\u003e\n\u003cp\u003eA baseboard heater or an electric furnace converts electricity into heat one for one. With a heat pump, the outdoor unit draws heat from the outside air and transfers it to your coil, which gives it to the air in the duct system. The furnace stays in reserve for the coldest days, based on a threshold we program with you.\u003c\/p\u003e\n\u003cp\u003eThis arrangement, called \"add-on,\" keeps the blower, filters and ducts of your current furnace. It avoids tearing anything out.\u003c\/p\u003e\n\n\u003ch3\u003eComparison with the other EAA5X models\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X24M14A\u003c\/strong\u003e: same capacity, but 13-1\/8 in wide. Preferable if the furnace is narrow.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X30M17A\u003c\/strong\u003e: same 16-7\/16 in width, but 2.5 tons and different outdoor units (Q5H9V24*K*AAA and N5H9V24*K*AAA).\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X36M17A\u003c\/strong\u003e and \u003cstrong\u003eEAA5X37M17A\u003c\/strong\u003e: same width, but 3 tons.\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eEAA5X42M21A\u003c\/strong\u003e, \u003cstrong\u003eEAA5X48M21A\u003c\/strong\u003e, \u003cstrong\u003eEAA5X61M21A\u003c\/strong\u003e and \u003cstrong\u003eEAA5X60M24A\u003c\/strong\u003e: larger widths, for more spacious homes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe M17A therefore stands out for its combination of small capacity and intermediate width. If your furnace measures 16-7\/16 in, choosing the M14A would mean a transition; if it is narrow, it is the other way around.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical details to keep in mind\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eBrand and range: Comfortmaker, EAA5X.\u003c\/li\u003e\n\u003cli\u003eCategory: uncased coil.\u003c\/li\u003e\n\u003cli\u003eRefrigerant: R-454B.\u003c\/li\u003e\n\u003cli\u003eDimensions W × H × D: 16-7\/16 × 19-7\/8 in.\u003c\/li\u003e\n\u003cli\u003eCondensate removal: 3\/4 in FPT primary and secondary drain connections.\u003c\/li\u003e\n\u003cli\u003eSafety: factory-mounted 5 V refrigerant sensor (generation 2). It does not work with generation 1 dissipation boards.\u003c\/li\u003e\n\u003cli\u003eManufacturer's warranty: 10 years on parts with registration within 90 days of installation, 5 years without registration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eManual IM-EAA5X-05 calls for a furnace compatible with generation 2 dissipation when the coil is installed uncased. We check this on your unit before any order.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation day\u003c\/h3\u003e\n\u003cp\u003eAirGreen is a family-owned \u003cstrong\u003eheating and cooling\u003c\/strong\u003e company, based in Montreal for more than fifteen years, and our refrigeration, ventilation and electrical work is covered by RBQ licence 5645-9605-01. A typical day:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ein the morning, we measure the furnace, check the blower and look at the electrical panel;\u003c\/li\u003e\n\u003cli\u003ewe set the coil, build the transition if needed and seal the duct joints;\u003c\/li\u003e\n\u003cli\u003eoutside, we install the unit on a pad or bracket, braze the piping, run the nitrogen leak test and pull a vacuum;\u003c\/li\u003e\n\u003cli\u003ewe connect the condensate drain and the thermostat;\u003c\/li\u003e\n\u003cli\u003ewe start up the system, adjust the airflow and explain how it works.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eThree checks before buying\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe coil uses R-454B: the outdoor unit must too, and the two are installed together.\u003c\/li\u003e\n\u003cli\u003ePerformance ratings exist only for the certified match.\u003c\/li\u003e\n\u003cli\u003eThe width and blower of your furnace must be suitable; we confirm this at your home.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eWho is behind the brand\u003c\/h3\u003e\n\u003cp\u003eComfortmaker is part of International Comfort Products (ICP), a Carrier subsidiary. Its R-454B evaporator coils are matched with the brand's central heat pumps and air conditioners, on a furnace or blower cabinet. ENERGY STAR matches are published under the \"EA*5X\" family with the Q5H9V, N5H9V, SoftSound B5H0V, B5H3V, C5H0V heat pumps and the Mainline C5H8T.\u003c\/p\u003e\n\n\u003ch3\u003eLogisVert incentive\u003c\/h3\u003e\n\u003cp\u003eThe matched Comfortmaker system appears on Hydro-Québec's list of eligible heat pumps. The amount varies with the installation date and your situation: we read it from the official list when we prepare your quote, then put the application together with you.\u003c\/p\u003e\n\n\u003ch3\u003eRequest your estimate\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBook a free estimate visit: we measure the furnace, assess the electrical service and give you a written quote for the complete system. \u003ca href=\"\/en\/pages\/financement-avec-financeit\"\u003eFinancing\u003c\/a\u003e is available to spread out the expense.\u003c\/strong\u003e\u003c\/p\u003e\n","brand":"Comfortmaker","offers":[{"title":"Default Title","offer_id":68402718769444,"sku":"EAA5X24M17A","price":0.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0715\/1694\/6724\/files\/SERPENTIN_D_EVAPORATEUR_COMFORTMAKER_EAA5X_EAA5X24M17A_00_2_TONNES_24000_BTU_MONTREAL_LAVAL_LONGUEUIL_RIVE_SUD_RIVE_NORD.png?v=1795765769","url":"https:\/\/airgreen.ca\/en\/products\/serpentin-devaporateur-comfortmaker-eaa5x24m17a-a-2-tonnes","provider":"AirGreen Climatisation \u0026 Chauffage \/ Air Conditioning \u0026 Heating","version":"1.0","type":"link"}